R E T A I L F O R L E A S E7 5 4 4 D U B L I N B O U L E VA R DD U B L I N , C A L I F O R N I A
1-mile 3-mile 5-mile
POPULATION 11,425 78,090 187,701
AVERAGE HH INCOME $126,303 $148,230 $160,656
DAYTIME POPULATION 32,218 96,249 209,201
F E A T U R E S
• ±10,332 SF OF RETAIL SPACE AVAILABLE
y CONVENIENT ACCESS TO AND FROM I-580 AND I-680
y CENTRALLY LOCATED IN DUBLIN RETAIL TRADE AREA
yWALKING DISTANCE TO BART STATION
y LOCATED AT THE SIGNALIZED INTERSECTION OF
DUBLIN BOULEVARD AND GOLDEN DATE DRIVE
y 313 APARTMENT UNITS ABOVE
y FLEXIBLE DEMISING OPTIONS
y 97 DEDICATED RETAIL PARKING SPACES
2017 DEMOGRAPHICS
TRAFFIC COUNTS
DUBLIN BOULEVARD - 28,000 ADT
INTERSTATE 680 - 167,000 ADT
INTERSTATE 580 - 214,000 ADT
R E T A I L F O R L E A S E
S I T E P L A N
SHEET NOTES
GENERAL NO
TES
FIRE DEPARTMENT KEY-BO
X LOCATIO
N
DESIGN/BUILD O
VERHEAD COILING
SECURITY GATE
WITH KEYED & FO
B-CONTRO
LLED ACCESS. GATE
SHALL MEET REQ
.S OF CFC SECTIO
N 1008.1.4.4.
DESIGN/BUILD STL HO
T-DIPPED GALV. SECURITY SITE
GATE BY G
.C. PER DESIGN INTENT M
OUNTED O
N STRUCTURALLY ISO
LATED TUBE STL, SEE 6/A8.40
CONCRETE SHEAR W
ALL, S.S.D. SEE A10.00 FOR W
ALL ASSEM
BLIES
CONCRETE W
HEEL STOP
43" STEEL GUARD RAIL
STANDARD PARKING SPACE, TYP. (9'-0" x 20'-0")
COM
PACT PARKING SPACE, TYP. (8'-0" x 17'-0")
TYPICAL ACCESSIBLE PARKING SPACE PER A0.5
VAN-ACCESSIBLE PARKING SPACE PER A0.5
ADA STRIPING
FLOO
R/AREA DRAINS, S.P.D., S.S.D.
CONCRETE CO
LUMN, S.S.D.
HOSE BIB. NO
N-REMO
VABLE BACKFLOW
PREVENTION
DEVICE SHALL BE INSTALLED ON ALL HO
SE BIBS AND PO
TABLE WATER O
UTLETS WITH HO
SE ATTACHM
ENTS. CPC 603.5.7
TRASH/RECYCLING BIN, 3'-0" W
, 3'-0" H, 6'-0" L. G.C. TO
VERIFY SIZE W
ITH LOCAL W
ASTE MANAG
EMENT
COM
PANY PRIOR TO
PURCHASE
3"H x 8"W CO
NC. CURB FOR DUM
PSTER WHEELSTO
P
TRASH CHUTE DISCHARGE W
/FUSIBLE LINK
TRASH CHUTE: UL 90 MIN "B" LABEL; TR
ASH C
HU
TE IN
TAKE DO
OR
S SHALL BE AC
TIVATED BY
ELECTR
ICALLY O
R PN
EUM
ATICALLY C
ON
TRO
LLED
PUSH
BUTTO
N, AN
D SH
ALL BE FULLY C
OM
PLIANT
WITH
ALL ADA R
EQU
IREM
ENTS.
TRASH
CH
UTE VEN
T
RAIN
WATER
LEADER
TO SPLASH
BLOC
K BELOW
10" SEISMIC G
AP, SEE 1 & 2/A8.14
FIRE SPR
INKLER
RISER
IN 1-H
R R
ATED R
ECESSED
C
ABINET: LAR
SEN FS VC
2626-R )W
HEN
NO
T IN A
STAIR). D
ESIGN
/BUILD
ENG
INEER
TO LO
CATE. W
HERE RISER DO
ES NOT O
CCUR WITHIN A STAIR
ENCLOSURE, PRO
VIDE FIRE-CAULKING AT EACH
FLOO
R PENETRATION.
INDICATES DROPPED G
WB CLG
W/ RECESSED "CAN"
LIGHTING
, SEE BLDG RCPS O
N SHEETS A6.1 & A6.2.
DASHED LINE INDICATES DROPPED G
WB CLG
W/
RECESSED "CAN" LIGHTING
AND SCORED 2' X 2'
CONCRETE AT FLO
OR
USPS-APPROVED RESIDENT M
AILBOXES W
/ REACH RANG
E BETWEEN 28" A.F.F. AND 54" A.F.F. O
NE PARCEL BO
X PER 10 RESIDENTS TO BE INCLUDED
OUTLINE O
F 2'-0" x 7'-0" GURNEY
VEHICULAR CLEARANCE BAR LOCATIO
N
2 HOUR FIRE RATED AREA SEPARATIO
N WALL - SEE
SHEET A10.0.
LINE OF LEVEL ABO
VE
A. DIMENSIO
NS ARE TO FACE O
F STUD, CONCRETE O
R FO
UNDATION W
ALL, TYP. U.O.N.
B. SEE A0.3 AND A0.4 FOR BUILDING
AREA CALCULATIONS.
C. SEE A0.6 FOR ACCESSIBILITY AND ADAPTABILITY
REQUIREM
ENTS.
D. SEE A0.7 - A0.11 FOR EG
RESS CALCS. AND DIAGRAM
S.
E. UNIT PLANS SHOW
N HERE ARE DIAGRAM
ATIC REFER TO 1/4"
UNIT PLANS AND ENLARGED PLANS FO
R ADDITIONAL
INFORM
ATION NO
T SHOW
N HERE.
F. SEE SHEET A10.0 FOR W
ALL TYPE SCHEDULE AND TYPICAL ASSEM
BLIES.
G. SEE LANDSCAPE DRAW
INGS FO
R INFORM
ATION REG
ARDING
THE GRADING
OF ALL EXTERIO
R AREAS.
H. CIVIL ELEV. 340.2' = ARCHITECTURAL ELEV. 0'-0".
I. ALL EXTERIOR W
OO
D WALLS TO
RECEIVE PLYWD SHEATHING
.
J. REFER TO STAIR DRAW
INGS FO
R INFORM
ATION NO
T SHOW
N HERE.
K. G.C. TO
COO
RDINATE MECH. AND PLUM
B. VENTS AS PERM
ITTED BY CODES TO
MINIM
IZE ROO
F PENETRATIONS.
L. G.C. TO
COO
RD. AND INSTALL VENTING FO
R ALL CONCEALED
ROO
F AREAS AND OTHER EXTR W
OO
D FRAMED VO
IDS.
M. ALL G
SM FLASHING
SHALL BE BONDERIZED AND PAINTED O
R RECEIVE CO
ATINGS TO
MATCH SURRO
UNDING M
ATERIALS.
N. ROO
F SLOPES NO
TED ARE MINIM
UMS. RO
OF SLO
PES OF
CRICKETS SHOW
N DIAGRAM
MATICALLY O
N ROO
F PLANS MAY
EXCEED 3/8"/FT TO ACHIEVE PRO
PER ROO
F DRAINAGE AS
SHOW
N.
O. G
.C. TO INCLUDE AND CO
ORDINATE RO
OF CRICKETS IN FIELD
FOR PRO
PER DRAINAGE IN ACCO
RDANCE WITH CO
DE AND RO
OF M
ANUFACTURER'S WARRANTY.
P. U.O.N., TYPICAL W
ALL TYPES AT FLOO
RS BELOW
PODIUM
SLAB TO
BE: 1. EXTERIO
R WALLS: TYPE B. SEE EXTERIO
RELEVATIO
NS FO
R FINISH TYPES AND LOCATIO
NS. 2. INTERIO
R WALLS: TYPE P1.
3. INTERIOR 2-HR RATED W
ALLS: TYPE R.U.O
.N., TYPICAL WALL TYPES AT FLO
ORS ABO
VE PODIUM
SLAB TO
BE: 1. EXTERIO
R BUILDING W
ALLS INCLUDING W
ALLS AT CO
URTYARDS: TYPE C1. SEE EXTERIOR ELEVATIO
NS FOR
FINISH TYPES AND LOCATIO
NS.2 . INTERIO
R CORRIDO
R WALLS: TYPE E.
3. INTERIOR STAIR/ELEVATO
R SHAFT WALLS: TYPE D2 AT
CORRIDO
R / TYPE H2 ADJACENT TO DW
ELLING UNIT
4. UNIT DEMISING
WALLS: TYPE H1.
5. 2-HR MECHANICAL SHAFT W
ALLS: K.6 . INTERIO
R UNIT WALLS: TYPE G
OR D1.
7. FIRE WALLS TO
BE TYPE "J" U.O.N.
Q. W
HERE WALL FINISHES DO
NOT ALIG
N DUE TO CHANG
E IN W
ALL TYPE, GC TO
PROVIDE BACKING
TO ENSURE A FLUSH
FINISH TRANSITION
R. SEE A8 SERIES SHEETS FOR TYP. RO
OF PIPE PENETRATIO
N & W
ATERPROO
FING INFO
RMATIO
N
S. U.O.N., ALL EXTERIO
R DWELLING
UNIT DECKS AND EXPOSED
CONCRETE SURFACES TO
RECEIVE WATERPRO
OF TRAFFIC
COATING
PER SPECIFICATIONS. SEE ALSO
LANDSCAPE PLANS FO
R EXTERIOR AREAS THAT ARE TO
RECEIVE PAVERS.
T. REINFORCED 15-M
IL VAPOR BARRIER TO
BE PROVIDED
UNDER SLAB, TYP. SEE BE DRAWING
FOR EXCEPTIO
NS.
U. STANDPIPE LOCATIO
NS SHOW
N ON PLANS ARE
DIAGRAM
MATIC; FIRE SPRINKLER SUBCO
NTRACTOR TO
PRO
VIDE STANDPIPE LOCATIO
N PLAN FOR REVIEW
BY ALAM
EDA COUNTY FIRE DEPARTM
ENT. PER CBC 905.4, CLASS I STANDPIPE HO
SE CONNECTIO
NS SHALL BE PROVIDED IN THE
FOLLO
WING
LOCATIO
NS:1. IN EVERY STAIRW
AY AT THE INTERMEDIATE LANDING
LEVEL2. O
N EACH SIDE OF HO
RIZONTAL EXITS
3. AT EACH EXIT PASSAGEW
AY, AT THE ENTRANCE FROM
THE EXIT PASSAG
EWAY TO
OTHER BUILDING
AREAS4. W
HERE THE MO
ST REMO
TE PORTIO
N OF A FLO
OR IS M
ORE
THAN 150' FROM
A HOSE CO
NNECTION
5. WHERE THE RO
OF HAS A SLO
PE LESS THAN 4 UNITS
VERTICAL IN 12 UNITS HORIZO
NTAL, A HOSE CO
NECTION
SHALL BE LO
CATED TO SERVE THE RO
OF O
R AT THE
HIGHEST LANDING
OF A STAIRW
AY WITH STAIR ACCESS TO
THE ROO
F.
V. FOR STRUCTURAL M
EMBERS REQ
UIRING INDIVIDUAL FIRE
PROTECTIO
N, SEE STRUCTURAL DRAWING
S. SEE ALSO 1/A9.20.
W. EXTERIO
R WALLS O
F VERTICAL EXIT ENCLOSURE THAT ARE
LOCATED AT AN ANG
LE OF LESS THAN 180º AND W
ITHIN 10 FEET HO
RIZONTALLY O
F A NON-RATED W
ALL OR UNPRO
TECTED O
PENING SHALL HAVE A FIRE-RESISTIVE RATING
OF NO
T LESS THAN 1-HR. O
PENINGS W
ITHIN SUCH EXTERIOR W
ALLS SHALL BE PRO
TECTED BY OPENING
PROTECTIVES HAVING
A FIRE PRO
TECTION RATING
OF NO
T LESS THAN 3/4 HOUR. THIS
CONSTRUCTIO
N SHALL EXTEND VERTICALLY FROM
THE G
ROUND TO
A POINT 10' ABO
VE THE TOPM
OST LANDING
OF THE
STAIRWAY O
R TO THE RO
OF LINE, W
HICHEVER IS LOW
ER PER CBC 1022.7.
X. FIRE WALL SHALL TERM
INATE AT A POINT NO
T LESS THAN 30" ABO
VE THE LOW
ER ROO
F LEVEL. THE EXTERIOR W
ALL ABO
VE THE LOW
ER ROO
F SHALL NOT HAVE LESS THAN A 1-HR
FIRE-RESISTANCE-RATED CONSTRUCTIO
N FROM
BOTH SIDES
WITH O
PENINGS PRO
TECTED BY FIRE ASSEMBLIES HAVE A A
FIRE PROTECTIO
N RATING O
F NOT LESS THAN 3/4 HR FO
R A MIN
MINIM
UM HEIG
HT OF 15 FEET PER SECTIO
N 706.6.1.
Y. G.C. SHALL PRO
VIDE EMERG
ENCY ALARM/W
ARNING SYSTEM
CAPABLE O
F ACTIVATING A M
EANS OF W
ARNING FO
R THE HEARING
IMPAIRED PER CBC 1007.11 AS PART O
F THE DESIGN
BUILD SYSTEM.
Z. 2-WAY CO
MM
UNICATION DEVICE CO
NECTED TO CENTRAL
CONTRO
L POINT AND SPECIFIC DIRECTIO
NS RELATED TO THE
USE OF EM
ERGENCY CO
MM
UNICATIONS SYSTEM
TO BE
PROVIDED AT EACH ELEVATO
R LANDING PER CBC 1007.8.1.
AA. JOINTS M
ADE IN OR BETW
EEN FIRE BARRIERS, AND JOINTS
MADE AT THE INTERSECTIO
N OF FIRE BARRIERS W
ITH UNDERSIDE O
F FIRE-RESISTANCE RATED FLOO
R OR RO
OF
SHEATHING, SLAB, O
R DECK ABOVE, AND THE EXTERIO
R VERTICAL W
ALL INTERSECTIONSHALL CO
MPLY W
ITH ALL REQ
UIRMENTS O
F CBC 715. THE VOIDS CREATED AT THE
INTERSECTION O
F A FIRE BARRIER AND A NO
N-FIRE-RESISTANCE-RATED ROO
F ASSEMBLY SHALL BE
FILLED PER REQUIRM
ENTS OF CBC 707.9.
BB. SMO
KE DAMPERS SHALL BE PRO
VIDED AT ALL DUCT PENETRATIO
NS OF O
F 1-HR FIRE RATED CORRIDO
R WALLS AND
CEILINGS ASSEM
BLIES PER CBC 714.4.1.2.
CC. GC IS TO
INCLUDE SPRINKLER HEADS AT ALL FURRED OUT
VOIDS AT EXTERIO
R WALLS.
SHEET NOTES, CO
NTINUEDLINE O
F ROO
F BELOW
STRUCTURAL DRAIN TO PIPE - S.P.D.
GSM
OVERLAND RELEASE SCUPPER
ROO
F DRAIN WITH O
VERFLOW
TO RAINW
ATER LEADER, SEE DETAIL 7/A8.00
ROO
F VENT, SEE DETAIL 12/A8.00
2-HR VENT SHAFT TO RO
OF - S.M
.D.
PARAPET WALL, SEE ELEVATIO
NS
ELEVATOR PENTHO
USE WITH 24" x 24" G
SM
HOISTW
AY VENT
ROO
FTOP HVAC EQ
UIPMENT M
OUNTED O
N PAD ADJACENT TO
PARAPET WALL, SEE 9&10/A8.00
WHITE TPO
ROO
FING
SEMI-RECESSED FIRE EXTING
UISHER & CABINET: LARSEN M
ODEL 2712 ALUM
INUM FRAM
E WITH G
LASS W
INDOW
OR APP'D EQ
. USE SURFACE-MTD CABINET
AT CONCRETE &CM
U WALLS. EXTING
UISHER TYPE 2A10BC. G
.C. TO INCLUDE IN PRICE (20) EXTRA FIRE
EXTINGUISHERSAND CABINETS TO
BE LOCATED PER
DIRECTION O
F LOCAL FIRE DEPARTM
ENT. WHERE
WALLS ARE REQ
UIRED TO HAVE A FIRE-RESISTANCE
RATING, FIXTURES SHALL BE INSTALLED SUCH THAT
THE REQUIRED FIRE-RESISTANCE SHALL NO
T BE REDUCED.SURFACE M
TD FIRE EXTINGUISHER AT CO
NCRETE
ROO
F PROTECTIO
N WALK PAD
COUNTERTO
P WITH G
ROM
METS O
VER CABINET FOR
TRASH / RECYCLING
HORIZO
NTAL EXIT AND STANDPIPES PER CBC 1025, CBC 905.4 AND CFC 702.3
36" HIGH HO
T-DIP GALVANIZED, PAINTED HANDRAIL
WITH 12" TO
P EXTENSION & 24" BO
TTOM
EXTENSION
GC SHALL PAINT SO
UTH FACADE OF (E) BUILDING
LINE OF SLAB EDG
E BELOW
MECHANICAL W
ALL PENETRATION - S.M
.D. FOR SIZE
AND COVER TYPE. ALL DUCT AND AIR TRANSFER
OPENING
S MUST CO
MPLY W
ITH FIRE PROTECTIO
N REQ
UIRMENTS O
F CBC 714.1.1.
HATCHING INDICATES 4'-0" ZO
NE MEASURED FRO
M
CENTERLINE OF 2-HR FIRE W
ALL WHERE SUCH W
ALL IS PERM
ITTED TO TERM
INATE AT THE UNDERSIDE OF
THE ROO
F SHEATHING IN W
HICH THERE ARE NO
OPENING
S IN THE ROO
F WITHIN 4 FEET O
F THE FIRE W
ALL, THE ROO
F IS COVERED W
ITH A MINIM
UM
CLASS B ROO
F COVERING
AND THE ROO
F SHEATHING
IS CONSTRUCTED O
F FIRE-RETARDANT-TREATED PLYW
OO
D FOR A M
INIMUM
DISTANCE OF 4 FEET O
N BO
TH SIDES OF THE FIRE W
ALL PER CBC 706.6, EXCEPTIO
N 4.
STACKING BICYCLE STO
RAGE SYSTEM
BY SARIS OR
APPROVED EQ
UAL
INDUSTRIAL DOUBLE W
ASH SINK
GAS M
ITIGATIO
N RISER - SEE VAPOR M
ITIGATIO
N DRAW
INGS, LISTED IN SHEET INDEX 1/A0.0
SECURITY PHONE PER DM
C 7.32.300; SEC 1010(K)(3)
SUMP W
ITH DRAIN, S.P.D.
60" L, 44" W, 60" H CEILING
-MO
UNTED FAN, S.M.D,
S.S.D.
DESIGN/BUILD FULL-HEIG
HT PAINTED HOT-DIP
GALVANIZED STEEL PICKET SECURITY FENCE
TRUNCATED DOM
ES
DROP CAP, S.S.D.
INFILL OPENING
WITH CM
U WALL 43" A.F.F. CO
NT ALO
NG RAM
P. DESIGN/BUILD HO
T-DIPPED G
ALVANIZED DECORATIVE M
TL RAILING INFRO
NT PER ELEVATIO
NS, PAINTED BLACK, SEE A8.40.
GARAG
E EXHAUST VENT, CONTINUO
US THROUG
H TO
ROO
F, S.M.D.
SUN SHADE
DESIGN/BUILD HO
T-DIPPED GALVANIZED STEEL
CANOPY, PAINTED BLACK, SEE 3/A8.41
TRENCH DRAIN
WALL-M
OUNTED BIKE RACK
SOIL BENEATH P.T. SLAB, S.S.D.
CAR CHARGER STATIO
N-TYPE I
CAR CHARGER STATIO
N-TYPE II
ASSUMED LO
CATION O
F FUTURE DEMISING
WALL
PARTIAL-HEIGHT W
ALL WITH RAILING
OUTLINE O
F MECHANICAL VENT SHAFT ABO
VE WITH
3-HR ENCLOSURE AT BO
TTOM
PER CBC 713.11. (SHAFT THAT DO
ES NOT EXTEND TO
THE UNDERSIDE O
F THE ROO
F SHEATHING, DECK O
R SLAB SHALL BE ENCLO
SED WITH A 2-HR ENCLO
SURE AT TOP PER
CBC 713.11 AND 713.12.)
24" X 24" WALK PAD
CONDENSO
R UNIT, S.M.D.
CONDENSO
R PAD AND LOW
WALL
DIRECTIONAL SIG
NAGE INDICATING
ACCESSIBLE PATHS O
F TRAVEL AND WARNING
OF
NON-ACCESSIBLE PATH
12" SEISMIC G
AP
12" SEISMIC G
AP AT 2-HR FIRE-RATED SEPARATION,
SEE 3/A8.14
REMO
VABLE LIFT STORAG
E
G.C. SHALL FILL ALL JO
INTS IN BETWEEN
STRUCTURAL COLUM
NS AND ADJACENT WALLS, TYP.,
WITH APPRO
VED SEALANT, MEETING
ALL REQ
UIREMNTS FO
R JOINTS AND VO
IDS AT INTERSECTIO
NS PER CBC 707.8 AND 707.9.
2-WAY CO
MM
UNICATION DEVICE TO
BE PROVIDED AT
EACH ELEVATOR LANDING
MEETING
ALL REQ
UIRMENTS O
F CBC 1007.8.1.
ROLL-DO
WN O
VERHEAD COILING
"SMO
KEGUARD"
DOO
R OR APPRO
VED EQUAL O
N MAG
NETIC AUXILIARY TRACK
REMO
VABLE LIFT LOCATIO
N - S.L.A.D.
8"-WIDE TRENCH DRAIN, S.S.D.
DESIGN/BUILD HO
T-DIPPED GALVANIZED SECURITY
SCREEN, PAINTED BLACK. SEE 13/A8.40
"UNAUTHORIZED VEHICLE" PARKING
SIGN PER CBC
1109A.8.8 & 11B-502.8, DEFERED SUBMITTAL.
DESIGNATED PARKING
FOR FUEL-EFFICIENT AND
CARPOO
L/VANPOO
L VEHICLES, PER CGBC TABLE
5.106.5.1.1 AND PARKING CALCULATIO
NS 4/A0.1. PAINTING
AT STALL TO BE SUCH THAT THE LO
WER
EDGE O
F THE LAST WO
RD ALIGNS W
ITH THE END OF
THE STALL STRIPING AND IS VISIBLE BENEATH A
PARKED VEHICLE PER CGBC AT.106.5.13.
LEGEND
STUD WALL
PARTIAL HEIGHT W
ALL
1-HOUR FIRE RATED W
ALL
CONCRETE W
ALL/COLUM
N, S.S.D.
SEE A10.0 FOR SPECIFIC W
ALL TYPES
2-HOUR FIRE RATED W
ALL
FULL HEIGHT CM
U WALL
PARTIAL HEIGHT CM
U WALL
w/ METAL STUD W
ALL ABOVE
DROPPED CEILING
PROPERTY LINE
FIRE EXTINGUISHER
CC-I
CC-II
CAR CHARGING
STATION-TYPE I
CAR CHARGING
STATION-TYPE II
W/D
UP
UP
FIRE WALL TERM
INATION (FLO
ORS 1, 2, 3, & 4):
CBC SEC. 706.5 HORIZ. CO
NTINUITY: EXCEPTIO
N 1 - FIRE WALL TERM
INATES AT 1-HR FIRE RATED EXTERIOR W
ALL; NO
OPENING
S OCCUR W
ITHIN 4'-0" OF EITHER SIDE O
F FIRE WALL
TERMINATIO
N AT THIS LOCATIO
N.
CBC SEC. 706.5.1 EXTERIOR W
ALLS:O
PTION 1 - EXTERIO
R WALLS O
N BOTH SIDES O
F FIRE WALL TERM
INATION ARE
1-HR FIRE-RATED AND EXTEND 4'-0" MIN AW
AY FROM
FIRE WALL TERM
INATION.
NO O
PENINGS O
CCUR WITHIN 4'-0" O
F EITHER SIDE OF FIRE W
ALL TERM
INATION AT THIS LO
CATION.
CBC SEC. 706.5.2 HORIZ. PRO
JECTING ELEM
ENTS:NO
PROJECTING
ELEMENTS AT THIS LO
CATION.
A1-1NO
:1011 BDRM722 S.F.
TYPE:
A2-1NO
:1041 BDRM707 S.F.
TYPE:
A1-1NO
:1021 BDRM722 S.F.
ROO
M--
173 MAIL
ROO
M--
171 ELEC.
TERMINATIO
N-1--
01
RUBBISH
STAGING--
16
RES. TRASH
ROO
M--
163
BOO
STER PUMP
STORAG
E--158
BICYCLE
STORAG
E--164
BICYCLE
--165
RETAIL--166
RETAIL--167
RETAIL--168
RETAIL--169
RESTAURANT
STORAG
E--162
BICYCLE
STAIR 2--4
ELEVATOR 2--
(RETAIL EV CHARGING
STATIO
N TO ADA STD.
NOT M
ARKED AS ACCESSIBLE)
3668 S.F.
1340 S.F.
1370 S.F.
1342 S.F.
2612 S.F.
All d
rawin
gs a
nd w
ritte
n m
ate
ria
lappearin
g h
erein
constitu
te o
rig
inal,
and u
npublis
hed w
ork o
f th
e a
rchite
ct
and m
ay n
ot b
e d
uplic
ate
d, u
sed o
rdis
clo
sed w
ithout th
e w
ritte
n c
onsent
of th
e a
rchite
ct.
BLDG PLANS
Drawn B
yIM
Project N
o.
Sheet S
ize: 3
0 x
42
Scale
1/8"=1'-0"
FLOO
R 1
A2.1A
Sheet T
itle
ZONE A
S t a
m p
Date
Issue
---
--------------------------- ---
---------------------------
Clie
nt
Consulta
nt
95
0H
ow
ard
St
ere
tS
an
Fran
cis
co
P.
415
677
0966
()
-
CA
94103
DUBLIN APARTMENTS
7544 Dublin Boulevard
Dublin, CA 94568
10.17.14DD Prog. Check Set
1429
10.31.14100%
DD Set
11.14.1425%
CD Set
50% CD Set
12.12.14
Permit Set
01.09.15
02.03.15Pricing Set 1
103.27.15
Permit Rev.
206.08.15
Permit Rev.
308.05.15
Permit Rev.
408.20.15
Permit Rev.
509.23.15
Construction Set
TRUENO
RTH
PROJECT
NORTH
016
84
All d
rawin
gs a
nd w
ritte
n m
ate
ria
lappearin
g h
erein
constitu
te o
rig
inal,
and u
npublis
hed w
ork o
f th
e a
rchite
ct
and m
ay n
ot b
e d
uplic
ate
d, u
sed o
rdis
clo
sed w
ithout th
e w
ritte
n c
onsent
of th
e a
rchite
ct.
BLDG PLANS
Drawn B
yIM
Project N
o.
Sheet S
ize: 3
0 x
42
Scale
1/8"=1'-0"
FLOO
R 1
A2.1B
Sheet T
itle
ZONE B
S t a
m p
Date
Issue
---
--------------------------- ---
---------------------------
Clie
nt
Consulta
nt
95
0H
ow
ard
St
ere
tS
an
Fran
cis
co
P.
415
677
09
66
()
-
CA
94103
DUBLIN APARTMENTS
7544 Dublin Boulevard
Dublin, CA 94568
10.17.14DD Prog. Check Set
1429
10.31.14100%
DD Set
11.14.1425%
CD Set
50% CD Set
12.12.14
Permit Set
01.09.15
02.03.15Pricing Set 1
103.27.15
Permit Rev.
206.08.15
Permit Rev.
308.05.15
Permit Rev.
408.20.15
Permit Rev.
509.23.15
Construction Set
W/D
W/D
W/D
W/D
UP
FIRE WALL TERM
INATION (FLO
ORS 1, 2, 3, & 4):
CBC SEC. 706.5 HORIZ. CO
NTINUITY: EXCEPTIO
N 1 - FIRE WALL TERM
INATES AT 1-HR FIRE RATED EXTERIOR W
ALL; NO
OPENING
S OCCUR W
ITHIN 4'-0" OF EITHER SIDE O
F FIRE WALL
TERMINATIO
N AT THIS LOCATIO
N.
CBC SEC. 706.5.1 EXTERIOR W
ALLS:O
PTION 1 - EXTERIO
R WALLS O
N BOTH SIDES O
F FIRE WALL TERM
INATION ARE
1-HR FIRE-RATED AND EXTEND 4'-0" MIN AW
AY FROM
FIRE WALL TERM
INATION.
NO O
PENINGS O
CCUR WITHIN 4'-0" O
F EITHER SIDE OF FIRE W
ALL TERM
INATION AT THIS LO
CATION.
CBC SEC. 706.5.2 HORIZ. PRO
JECTING ELEM
ENTS:NO
PROJECTING
ELEMENTS AT THIS LO
CATION.
A4-1NO
:1061 BDRM796 S.F.
TYPE:
A2-1NO
:1041 BDRM707 S.F.
TYPE:A4-1NO
:1081 BDRM796 S.F.
TYPE:A4-1NO
:1101 BDRM796 S.F.
TYPE:
ROO
M--
171 ELEC.
OFFICE--
177
LEASING
TRASH--174
RESTAURANT
--175
RETAIL
--176
RESTAURANT
STAIR 1--4
MECH.
--
2295 S.F.
3575 S.F.
SHEET NOTES
GENERAL NO
TES
FIRE DEPARTMENT KEY-BO
X LOCATIO
N
DESIGN/BUILD O
VERHEAD COILING
SECURITY GATE
WITH KEYED & FO
B-CONTRO
LLED ACCESS. GATE
SHALL MEET REQ
.S OF CFC SECTIO
N 1008.1.4.4.
DESIGN/BUILD STL HO
T-DIPPED GALV. SECURITY SITE
GATE BY G
.C. PER DESIGN INTENT M
OUNTED O
N STRUCTURALLY ISO
LATED TUBE STL, SEE 6/A8.40
CONCRETE SHEAR W
ALL, S.S.D. SEE A10.00 FOR W
ALL ASSEM
BLIES
CONCRETE W
HEEL STOP
43" STEEL GUARD RAIL
STANDARD PARKING SPACE, TYP. (9'-0" x 20'-0")
COM
PACT PARKING SPACE, TYP. (8'-0" x 17'-0")
TYPICAL ACCESSIBLE PARKING SPACE PER A0.5
VAN-ACCESSIBLE PARKING SPACE PER A0.5
ADA STRIPING
FLOO
R/AREA DRAINS, S.P.D., S.S.D.
CONCRETE CO
LUMN, S.S.D.
HOSE BIB. NO
N-REMO
VABLE BACKFLOW
PREVENTION
DEVICE SHALL BE INSTALLED ON ALL HO
SE BIBS AND PO
TABLE WATER O
UTLETS WITH HO
SE ATTACHM
ENTS. CPC 603.5.7
TRASH/RECYCLING BIN, 3'-0" W
, 3'-0" H, 6'-0" L. G.C. TO
VERIFY SIZE W
ITH LOCAL W
ASTE MANAG
EMENT
COM
PANY PRIOR TO
PURCHASE
3"H x 8"W CO
NC. CURB FOR DUM
PSTER WHEELSTO
P
TRASH CHUTE DISCHARGE W
/FUSIBLE LINK
TRASH CHUTE: UL 90 MIN "B" LABEL; TR
ASH C
HU
TE IN
TAKE DO
OR
S SHALL BE AC
TIVATED BY
ELECTR
ICALLY O
R PN
EUM
ATICALLY C
ON
TRO
LLED
PUSH
BUTTO
N, AN
D SH
ALL BE FULLY C
OM
PLIANT
WITH
ALL ADA R
EQU
IREM
ENTS.
TRASH
CH
UTE VEN
T
RAIN
WATER
LEADER
TO SPLASH
BLOC
K BELOW
10" SEISMIC G
AP, SEE 1 & 2/A8.14
FIRE SPR
INKLER
RISER
IN 1-H
R R
ATED R
ECESSED
C
ABINET: LAR
SEN FS VC
2626-R )W
HEN
NO
T IN A
STAIR). D
ESIGN
/BUILD
ENG
INEER
TO LO
CATE. W
HERE RISER DO
ES NOT O
CCUR WITHIN A STAIR
ENCLOSURE, PRO
VIDE FIRE-CAULKING AT EACH
FLOO
R PENETRATION.
INDICATES DROPPED G
WB CLG
W/ RECESSED "CAN"
LIGHTING
, SEE BLDG RCPS O
N SHEETS A6.1 & A6.2.
DASHED LINE INDICATES DROPPED G
WB CLG
W/
RECESSED "CAN" LIGHTING
AND SCORED 2' X 2'
CONCRETE AT FLO
OR
USPS-APPROVED RESIDENT M
AILBOXES W
/ REACH RANG
E BETWEEN 28" A.F.F. AND 54" A.F.F. O
NE PARCEL BO
X PER 10 RESIDENTS TO BE INCLUDED
OUTLINE O
F 2'-0" x 7'-0" GURNEY
VEHICULAR CLEARANCE BAR LOCATIO
N
2 HOUR FIRE RATED AREA SEPARATIO
N WALL - SEE
SHEET A10.0.
LINE OF LEVEL ABO
VE
A. DIMENSIO
NS ARE TO FACE O
F STUD, CONCRETE O
R FO
UNDATION W
ALL, TYP. U.O.N.
B. SEE A0.3 AND A0.4 FOR BUILDING
AREA CALCULATIONS.
C. SEE A0.6 FOR ACCESSIBILITY AND ADAPTABILITY
REQUIREM
ENTS.
D. SEE A0.7 - A0.11 FOR EG
RESS CALCS. AND DIAGRAM
S.
E. UNIT PLANS SHOW
N HERE ARE DIAGRAM
ATIC REFER TO 1/4"
UNIT PLANS AND ENLARGED PLANS FO
R ADDITIONAL
INFORM
ATION NO
T SHOW
N HERE.
F. SEE SHEET A10.0 FOR W
ALL TYPE SCHEDULE AND TYPICAL ASSEM
BLIES.
G. SEE LANDSCAPE DRAW
INGS FO
R INFORM
ATION REG
ARDING
THE GRADING
OF ALL EXTERIO
R AREAS.
H. CIVIL ELEV. 340.2' = ARCHITECTURAL ELEV. 0'-0".
I. ALL EXTERIOR W
OO
D WALLS TO
RECEIVE PLYWD SHEATHING
.
J. REFER TO STAIR DRAW
INGS FO
R INFORM
ATION NO
T SHOW
N HERE.
K. G.C. TO
COO
RDINATE MECH. AND PLUM
B. VENTS AS PERM
ITTED BY CODES TO
MINIM
IZE ROO
F PENETRATIONS.
L. G.C. TO
COO
RD. AND INSTALL VENTING FO
R ALL CONCEALED
ROO
F AREAS AND OTHER EXTR W
OO
D FRAMED VO
IDS.
M. ALL G
SM FLASHING
SHALL BE BONDERIZED AND PAINTED O
R RECEIVE CO
ATINGS TO
MATCH SURRO
UNDING M
ATERIALS.
N. ROO
F SLOPES NO
TED ARE MINIM
UMS. RO
OF SLO
PES OF
CRICKETS SHOW
N DIAGRAM
MATICALLY O
N ROO
F PLANS MAY
EXCEED 3/8"/FT TO ACHIEVE PRO
PER ROO
F DRAINAGE AS
SHOW
N.
O. G
.C. TO INCLUDE AND CO
ORDINATE RO
OF CRICKETS IN FIELD
FOR PRO
PER DRAINAGE IN ACCO
RDANCE WITH CO
DE AND RO
OF M
ANUFACTURER'S WARRANTY.
P. U.O.N., TYPICAL W
ALL TYPES AT FLOO
RS BELOW
PODIUM
SLAB TO
BE: 1. EXTERIO
R WALLS: TYPE B. SEE EXTERIO
RELEVATIO
NS FO
R FINISH TYPES AND LOCATIO
NS. 2. INTERIO
R WALLS: TYPE P1.
3. INTERIOR 2-HR RATED W
ALLS: TYPE R.U.O
.N., TYPICAL WALL TYPES AT FLO
ORS ABO
VE PODIUM
SLAB TO
BE: 1 . EXTERIO
R BUILDING W
ALLS INCLUDING W
ALLS AT CO
URTYARDS: TYPE C1. SEE EXTERIOR ELEVATIO
NS FOR
FINISH TYPES AND LOCATIO
NS.2. INTERIO
R CORRIDO
R WALLS: TYPE E.
3. INTERIOR STAIR/ELEVATO
R SHAFT WALLS: TYPE D2 AT
CORRIDO
R / TYPE H2 ADJACENT TO DW
ELLING UNIT
4. UNIT DEMISING
WALLS: TYPE H1.
5. 2-HR MECHANICAL SHAFT W
ALLS: K.6 . INTERIO
R UNIT WALLS: TYPE G
OR D1.
7. FIRE WALLS TO
BE TYPE "J" U.O.N.
Q. W
HERE WALL FINISHES DO
NOT ALIG
N DUE TO CHANG
E IN W
ALL TYPE, GC TO
PROVIDE BACKING
TO ENSURE A FLUSH
FINISH TRANSITION
R. SEE A8 SERIES SHEETS FOR TYP. RO
OF PIPE PENETRATIO
N & W
ATERPROO
FING INFO
RMATIO
N
S. U.O.N., ALL EXTERIO
R DWELLING
UNIT DECKS AND EXPOSED
CONCRETE SURFACES TO
RECEIVE WATERPRO
OF TRAFFIC
COATING
PER SPECIFICATIONS. SEE ALSO
LANDSCAPE PLANS FO
R EXTERIOR AREAS THAT ARE TO
RECEIVE PAVERS.
T. REINFORCED 15-M
IL VAPOR BARRIER TO
BE PROVIDED
UNDER SLAB, TYP. SEE BE DRAWING
FOR EXCEPTIO
NS.
U. STANDPIPE LOCATIO
NS SHOW
N ON PLANS ARE
DIAGRAM
MATIC; FIRE SPRINKLER SUBCO
NTRACTOR TO
PRO
VIDE STANDPIPE LOCATIO
N PLAN FOR REVIEW
BY ALAM
EDA COUNTY FIRE DEPARTM
ENT. PER CBC 905.4, CLASS I STANDPIPE HO
SE CONNECTIO
NS SHALL BE PROVIDED IN THE
FOLLO
WING
LOCATIO
NS:1. IN EVERY STAIRW
AY AT THE INTERMEDIATE LANDING
LEVEL2. O
N EACH SIDE OF HO
RIZONTAL EXITS
3. AT EACH EXIT PASSAGEW
AY, AT THE ENTRANCE FROM
THE EXIT PASSAG
EWAY TO
OTHER BUILDING
AREAS4. W
HERE THE MO
ST REMO
TE PORTIO
N OF A FLO
OR IS M
ORE
THAN 150' FROM
A HOSE CO
NNECTION
5. WHERE THE RO
OF HAS A SLO
PE LESS THAN 4 UNITS
VERTICAL IN 12 UNITS HORIZO
NTAL, A HOSE CO
NECTION
SHALL BE LO
CATED TO SERVE THE RO
OF O
R AT THE
HIGHEST LANDING
OF A STAIRW
AY WITH STAIR ACCESS TO
THE ROO
F.
V. FOR STRUCTURAL M
EMBERS REQ
UIRING INDIVIDUAL FIRE
PROTECTIO
N, SEE STRUCTURAL DRAWING
S. SEE ALSO 1/A9.20.
W. EXTERIO
R WALLS O
F VERTICAL EXIT ENCLOSURE THAT ARE
LOCATED AT AN ANG
LE OF LESS THAN 180º AND W
ITHIN 10 FEET HO
RIZONTALLY O
F A NON-RATED W
ALL OR UNPRO
TECTED O
PENING SHALL HAVE A FIRE-RESISTIVE RATING
OF NO
T LESS THAN 1-HR. O
PENINGS W
ITHIN SUCH EXTERIOR W
ALLS SHALL BE PRO
TECTED BY OPENING
PROTECTIVES HAVING
A FIRE PRO
TECTION RATING
OF NO
T LESS THAN 3/4 HOUR. THIS
CONSTRUCTIO
N SHALL EXTEND VERTICALLY FROM
THE G
ROUND TO
A POINT 10' ABO
VE THE TOPM
OST LANDING
OF THE
STAIRWAY O
R TO THE RO
OF LINE, W
HICHEVER IS LOW
ER PER CBC 1022.7.
X. FIRE WALL SHALL TERM
INATE AT A POINT NO
T LESS THAN 30" ABO
VE THE LOW
ER ROO
F LEVEL. THE EXTERIOR W
ALL ABO
VE THE LOW
ER ROO
F SHALL NOT HAVE LESS THAN A 1-HR
FIRE-RESISTANCE-RATED CONSTRUCTIO
N FROM
BOTH SIDES
WITH O
PENINGS PRO
TECTED BY FIRE ASSEMBLIES HAVE A A
FIRE PROTECTIO
N RATING O
F NOT LESS THAN 3/4 HR FO
R A MIN
MINIM
UM HEIG
HT OF 15 FEET PER SECTIO
N 706.6.1.
Y. G.C. SHALL PRO
VIDE EMERG
ENCY ALARM/W
ARNING SYSTEM
CAPABLE O
F ACTIVATING A M
EANS OF W
ARNING FO
R THE HEARING
IMPAIRED PER CBC 1007.11 AS PART O
F THE DESIGN
BUILD SYSTEM.
Z. 2-WAY CO
MM
UNICATION DEVICE CO
NECTED TO CENTRAL
CONTRO
L POINT AND SPECIFIC DIRECTIO
NS RELATED TO THE
USE OF EM
ERGENCY CO
MM
UNICATIONS SYSTEM
TO BE
PROVIDED AT EACH ELEVATO
R LANDING PER CBC 1007.8.1.
AA. JOINTS M
ADE IN OR BETW
EEN FIRE BARRIERS, AND JOINTS
MADE AT THE INTERSECTIO
N OF FIRE BARRIERS W
ITH UNDERSIDE O
F FIRE-RESISTANCE RATED FLOO
R OR RO
OF
SHEATHING, SLAB, O
R DECK ABOVE, AND THE EXTERIO
R VERTICAL W
ALL INTERSECTIONSHALL CO
MPLY W
ITH ALL REQ
UIRMENTS O
F CBC 715. THE VOIDS CREATED AT THE
INTERSECTION O
F A FIRE BARRIER AND A NO
N-FIRE-RESISTANCE-RATED ROO
F ASSEMBLY SHALL BE
FILLED PER REQUIRM
ENTS OF CBC 707.9.
BB. SMO
KE DAMPERS SHALL BE PRO
VIDED AT ALL DUCT PENETRATIO
NS OF O
F 1-HR FIRE RATED CORRIDO
R WALLS AND
CEILINGS ASSEM
BLIES PER CBC 714.4.1.2.
CC. GC IS TO
INCLUDE SPRINKLER HEADS AT ALL FURRED OUT
VOIDS AT EXTERIO
R WALLS.
SHEET NOTES, CO
NTINUEDLINE O
F ROO
F BELOW
STRUCTURAL DRAIN TO PIPE - S.P.D.
GSM
OVERLAND RELEASE SCUPPER
ROO
F DRAIN WITH O
VERFLOW
TO RAINW
ATER LEADER, SEE DETAIL 7/A8.00
ROO
F VENT, SEE DETAIL 12/A8.00
2-HR VENT SHAFT TO RO
OF - S.M
.D.
PARAPET WALL, SEE ELEVATIO
NS
ELEVATOR PENTHO
USE WITH 24" x 24" G
SM
HOISTW
AY VENT
ROO
FTOP HVAC EQ
UIPMENT M
OUNTED O
N PAD ADJACENT TO
PARAPET WALL, SEE 9&10/A8.00
WHITE TPO
ROO
FING
SEMI-RECESSED FIRE EXTING
UISHER & CABINET: LARSEN M
ODEL 2712 ALUM
INUM FRAM
E WITH G
LASS W
INDOW
OR APP'D EQ
. USE SURFACE-MTD CABINET
AT CONCRETE &CM
U WALLS. EXTING
UISHER TYPE 2A10BC. G
.C. TO INCLUDE IN PRICE (20) EXTRA FIRE
EXTINGUISHERSAND CABINETS TO
BE LOCATED PER
DIRECTION O
F LOCAL FIRE DEPARTM
ENT. WHERE
WALLS ARE REQ
UIRED TO HAVE A FIRE-RESISTANCE
RATING, FIXTURES SHALL BE INSTALLED SUCH THAT
THE REQUIRED FIRE-RESISTANCE SHALL NO
T BE REDUCED.SURFACE M
TD FIRE EXTINGUISHER AT CO
NCRETE
ROO
F PROTECTIO
N WALK PAD
COUNTERTO
P WITH G
ROM
METS O
VER CABINET FOR
TRASH / RECYCLING
HORIZO
NTAL EXIT AND STANDPIPES PER CBC 1025, CBC 905.4 AND CFC 702.3
36" HIGH HO
T-DIP GALVANIZED, PAINTED HANDRAIL
WITH 12" TO
P EXTENSION & 24" BO
TTOM
EXTENSION
GC SHALL PAINT SO
UTH FACADE OF (E) BUILDING
LINE OF SLAB EDG
E BELOW
MECHANICAL W
ALL PENETRATION - S.M
.D. FOR SIZE
AND COVER TYPE. ALL DUCT AND AIR TRANSFER
OPENING
S MUST CO
MPLY W
ITH FIRE PROTECTIO
N REQ
UIRMENTS O
F CBC 714.1.1.
HATCHING INDICATES 4'-0" ZO
NE MEASURED FRO
M
CENTERLINE OF 2-HR FIRE W
ALL WHERE SUCH W
ALL IS PERM
ITTED TO TERM
INATE AT THE UNDERSIDE OF
THE ROO
F SHEATHING IN W
HICH THERE ARE NO
OPENING
S IN THE ROO
F WITHIN 4 FEET O
F THE FIRE W
ALL, THE ROO
F IS COVERED W
ITH A MINIM
UM
CLASS B ROO
F COVERING
AND THE ROO
F SHEATHING
IS CONSTRUCTED O
F FIRE-RETARDANT-TREATED PLYW
OO
D FOR A M
INIMUM
DISTANCE OF 4 FEET O
N BO
TH SIDES OF THE FIRE W
ALL PER CBC 706.6, EXCEPTIO
N 4.
STACKING BICYCLE STO
RAGE SYSTEM
BY SARIS OR
APPROVED EQ
UAL
INDUSTRIAL DOUBLE W
ASH SINK
GAS M
ITIGATIO
N RISER - SEE VAPOR M
ITIGATIO
N DRAW
INGS, LISTED IN SHEET INDEX 1/A0.0
SECURITY PHONE PER DM
C 7.32.300; SEC 1010(K)(3)
SUMP W
ITH DRAIN, S.P.D.
60" L, 44" W, 60" H CEILING
-MO
UNTED FAN, S.M.D,
S.S.D.
DESIGN/BUILD FULL-HEIG
HT PAINTED HOT-DIP
GALVANIZED STEEL PICKET SECURITY FENCE
TRUNCATED DOM
ES
DROP CAP, S.S.D.
INFILL OPENING
WITH CM
U WALL 43" A.F.F. CO
NT ALO
NG RAM
P. DESIGN/BUILD HO
T-DIPPED G
ALVANIZED DECORATIVE M
TL RAILING INFRO
NT PER ELEVATIO
NS, PAINTED BLACK, SEE A8.40.
GARAG
E EXHAUST VENT, CONTINUO
US THROUG
H TO
ROO
F, S.M.D.
SUN SHADE
DESIGN/BUILD HO
T-DIPPED GALVANIZED STEEL
CANOPY, PAINTED BLACK, SEE 3/A8.41
TRENCH DRAIN
WALL-M
OUNTED BIKE RACK
SOIL BENEATH P.T. SLAB, S.S.D.
CAR CHARGER STATIO
N-TYPE I
CAR CHARGER STATIO
N-TYPE II
ASSUMED LO
CATION O
F FUTURE DEMISING
WALL
PARTIAL-HEIGHT W
ALL WITH RAILING
OUTLINE O
F MECHANICAL VENT SHAFT ABO
VE WITH
3-HR ENCLOSURE AT BO
TTOM
PER CBC 713.11. (SHAFT THAT DO
ES NOT EXTEND TO
THE UNDERSIDE O
F THE ROO
F SHEATHING, DECK O
R SLAB SHALL BE ENCLO
SED WITH A 2-HR ENCLO
SURE AT TOP PER
CBC 713.11 AND 713.12.)
24" X 24" WALK PAD
CONDENSO
R UNIT, S.M.D.
CONDENSO
R PAD AND LOW
WALL
DIRECTIONAL SIG
NAGE INDICATING
ACCESSIBLE PATHS O
F TRAVEL AND WARNING
OF
NON-ACCESSIBLE PATH
12" SEISMIC G
AP
12" SEISMIC G
AP AT 2-HR FIRE-RATED SEPARATION,
SEE 3/A8.14
REMO
VABLE LIFT STORAG
E
G.C. SHALL FILL ALL JO
INTS IN BETWEEN
STRUCTURAL COLUM
NS AND ADJACENT WALLS, TYP.,
WITH APPRO
VED SEALANT, MEETING
ALL REQ
UIREMNTS FO
R JOINTS AND VO
IDS AT INTERSECTIO
NS PER CBC 707.8 AND 707.9.
2-WAY CO
MM
UNICATION DEVICE TO
BE PROVIDED AT
EACH ELEVATOR LANDING
MEETING
ALL REQ
UIRMENTS O
F CBC 1007.8.1.
ROLL-DO
WN O
VERHEAD COILING
"SMO
KEGUARD"
DOO
R OR APPRO
VED EQUAL O
N MAG
NETIC AUXILIARY TRACK
REMO
VABLE LIFT LOCATIO
N - S.L.A.D.
8"-WIDE TRENCH DRAIN, S.S.D.
DESIGN/BUILD HO
T-DIPPED GALVANIZED SECURITY
SCREEN, PAINTED BLACK. SEE 13/A8.40
"UNAUTHORIZED VEHICLE" PARKING
SIGN PER CBC
1109A.8.8 & 11B-502.8, DEFERED SUBMITTAL.
DESIGNATED PARKING
FOR FUEL-EFFICIENT AND
CARPOO
L/VANPOO
L VEHICLES, PER CGBC TABLE
5.106.5.1.1 AND PARKING CALCULATIO
NS 4/A0.1. PAINTING
AT STALL TO BE SUCH THAT THE LO
WER
EDGE O
F THE LAST WO
RD ALIGNS W
ITH THE END OF
THE STALL STRIPING AND IS VISIBLE BENEATH A
PARKED VEHICLE PER CGBC AT.106.5.13.
LEGEND
STUD WALL
PARTIAL HEIGHT W
ALL
1-HOUR FIRE RATED W
ALL
CONCRETE W
ALL/COLUM
N, S.S.D.
SEE A10.0 FOR SPECIFIC W
ALL TYPES
2-HOUR FIRE RATED W
ALL
FULL HEIGHT CM
U WALL
PARTIAL HEIGHT CM
U WALL
w/ METAL STUD W
ALL ABOVE
DROPPED CEILING
PROPERTY LINE
FIRE EXTINGUISHER
CC-I
CC-II
CAR CHARGING
STATION-TYPE I
CAR CHARGING
STATION-TYPE II
016
84
TRUENO
RTH
PROJECT
NORTH
DUBLIN BLVD
GO
LD
EN
GA
TE
DR
±1,3
40
SF
±1,3
70 S
F
7545-7554
±3,668 SFCAN BE DEMISED
RETAIL PARKING SPACES
7550 7548
±1,3
42
SF
7546
±2,612 SF
7542-7544
ADDITIONAL RETAIL PARKING
AMAKARA SUSHILEASED
D U B L I N , C A
7544 is centrally located in the heart of Downtown Dublin along Dublin Boulevard near both Interstate 580 and Interstate 680.
With a growth rate of over 10% annually, Dublin is the fastest growing city in Northern California. While the Downtown area has always been a thriving regional shopping destination, recent plans have been developed promoting more growth with more pedestrian oriented, vibrant mixed use projects to take shape.
A block away, the West Dublin/Pleasanton BART Station serves over 3,750 riders a day.
309
Apartment
Units
SITEDUBLIN BLVD - 28,000 ADT
West DublinStation
500
Planned
Apartment
Units
214,000 ADT
167,000 ADT
±167,00
0 C
AR
S DA
ILY
DUBLIN RETAIL CENTER
HACIENDA CROSSING
SHOPS AT WATERFORD
FALLON GATEWAY
GRAFTON STATION
ROSE PAVILLION
PACIFIC PEARL
SHOPPES AT LIVERMORE
METRO 580PLEASANTON SQUARE
STONERIDGE MALL
DUBLIN PLACE
PERSIMMON PLACE
7 MILLION VISITORSPER YEAR
18 MILLION VISITORSPER YEAR
7544 DUBLIN BLVD.
±214,000 CARS DAILY
R E T A I L A E R I A L
Cushman & Wakefield Copyright 2018. No warranty or representation, express or implied, is made to the accuracy or completeness of the information contained herein, and same is submitted subject to errors, omissions, change of price, rental or other conditions, withdrawal without notice, and to any special listing conditions imposed by the property owner(s). As applicable, we make no representation as to the condition of the property (or properties) in question.
CO N TAC T F O R L E A S I N G I N F O R M A T I O N
NICOLE LYON +1 925 627 2485 [email protected] LIC #01975898
JAMES CHUNG +1 408 436 3630 [email protected] LIC #01408190