+ All Categories
Home > Documents > Reusable multi-lead ECG Leads - Draeger · 2019-11-28 · SECTION | 1 The new Dräger multi-lead...

Reusable multi-lead ECG Leads - Draeger · 2019-11-28 · SECTION | 1 The new Dräger multi-lead...

Date post: 19-Jan-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
2
The new Dräger multi-lead ECG leads offer enhanced ergonomic features and improved handling. The leads are now designed for easier cleaning and disinfection. These new reusable ECG leads are shielded to provide high signal quality. Our high quality ECG leads are designed for use with Dräger Infinity ® patient monitoring systems. IMPROVED DESIGN FOR FASTER, BETTER CONNECTIONS Dräger reusable ECG leads offer excep- tional durability and functionality. The high signal quality thanks to specially shielded cables supports the safety of your patients. The cables are coated with a new, skin-friendly material which helps reduce tangles and simplifies applica- tion. This new line of 3-, 5-, 6- and 12 lead ECG lead sets offers clear color-coding with European (IEC1) and American (IEC2/AHA) standards. The patient con- nectors are compatible with all standard electrodes and electrode connectors and are approved for adult and pediatric ap- plications. The new reusable ECG lead sets have been extensively tested and certified for use with the Dräger Infinity patient monitoring systems. The Dräger ECG leads are recommended for use in all hospital areas, as OR, ICU, ER, stroke units and in areas with telemetry devices. SAME FAMILIAR COLOR-CODING To make things easier on you and your staff, the same color-coding for monitor-end cable connectors as in previous models is used in our new line of reusable ECG cables. Dual-pin monitor connectors are light grey, while single-pin and telemetry connectors are green in color. ERGONOMIC MONITOR CONNECTORS In addition, the improved design of the monitor connector features a clearly vis- ible application label for proper electrode positioning. To make things easier for you and your staff, the length of the monitor connector has been extended and a newly designed grip supports easy connection and disconnection of the ECG leads. WELL THOUGHT-OUT DESIGN OF PATIENT CONNECTOR To support your daily workflow, our new patient connector design ensures an easi- er, more comfortable connection to the patent electrode. Additionally, all patient connectors are both color-coded and letter- labeled to facilitate error-free connections. EASIER CLEANING AND DISINFECTION Hygiene is essential in the daily work routine of any hospital. That’s why hygiene is an integral design element of all reusable Dräger accessories. Every component of the ECG lead sets is designed to facilitate easy cleaning and disinfection. To reduce the risk of cross contamination, the design of the patient connector avoids recessed or hard-to-reach spaces. A wide range of disinfectants have been tested and are approved for use. Reusable multi-lead ECG Leads D-96900-2013 Monitor Connector with Application Label D-99470-2013 Reusable multi-leads ECG Leads D-99292-2013 Patient Connectors D-99287-2013
Transcript
Page 1: Reusable multi-lead ECG Leads - Draeger · 2019-11-28 · SECTION | 1 The new Dräger multi-lead ECG leads offer enhanced ergonomic features and improved handling. The leads are now

SECTION | 1

The new Dräger multi-lead ECG leads offer enhanced ergonomic features and improved handling. The leads are now designed for easier cleaning and disinfection. These new reusable ECG leads are shielded to provide high signal quality. Our high quality ECG leads are designed for use with Dräger Infinity® patient monitoring systems.

IMPROVED DESIGN FOR FASTER,

BETTER CONNECTIONS

Dräger reusable ECG leads offer excep-tional durability and functionality. The high signal quality thanks to specially shielded cables supports the safety of your patients. The cables are coated with a new, skin-friendly material which helps reduce tangles and simplifies applica-tion. This new line of 3-, 5-, 6- and 12 lead ECG lead sets offers clear color-coding with European (IEC1) and American (IEC2/AHA) standards. The patient con-nectors are compatible with all standard electrodes and electrode connectors and are approved for adult and pediatric ap-plications. The new reusable ECG lead sets have been extensively tested and certified for use with the Dräger Infinity patient monitoring systems. The Dräger ECG leads are recommended for use in all hospital areas, as OR, ICU, ER, stroke units and in areas with telemetry devices.

SAME FAMILIAR COLOR-CODING

To make things easier on you and your staff, the same color-coding for monitor-end cable connectors as in previous models is used in our new line of reusable ECG cables. Dual-pin monitor connectors are light grey, while single-pin and telemetry connectors are green in color.

ERGONOMIC MONITOR CONNECTORS

In addition, the improved design of the monitor connector features a clearly vis-ible application label for proper electrode positioning. To make things easier for you and your staff, the length of the monitor connector has been extended and a newly designed grip supports easy connection and disconnection of the ECG leads.

WELL THOUGHT-OUT DESIGN

OF PATIENT CONNECTOR

To support your daily workflow, our new patient connector design ensures an easi-er, more comfortable connection to the patent electrode. Additionally, all patient connectors are both color-coded and letter-labeled to facilitate error-free connections.

EASIER CLEANING AND DISINFECTION

Hygiene is essential in the daily work routine of any hospital. That’s why hygiene is an integral design element of all reusable Dräger accessories. Every component of the ECG lead sets is designed to facilitate easy cleaning and disinfection. To reduce the risk of cross contamination, the design of the patient connector avoids recessed or hard-to-reach spaces. A wide range of disinfectants have been tested and are approved for use.

Reusable multi-lead ECG Leads

D-9

6900

-201

3

Monitor Connector with Application Label

D-9

9470

-201

3

Reusable multi-leads ECG Leads

D-9

9292

-201

3

Patient Connectors

D-9

9287

-201

3

Page 2: Reusable multi-lead ECG Leads - Draeger · 2019-11-28 · SECTION | 1 The new Dräger multi-lead ECG leads offer enhanced ergonomic features and improved handling. The leads are now

REUSABLE MULTI-LEAD ECG LEADS2 |

90 6

8 11

2 |

09.1

3-1

| C

omm

unic

atio

ns &

Sal

es M

arke

ting

| P

P |

LE

| P

rint

ed i

n G

erm

any

| C

hlor

ine-

free

– e

nvir

onm

enta

lly c

ompa

tible

| S

ubje

ct t

o m

odifi

catio

ns |

© 2

013

Drä

gerw

erk

AG

& C

o. K

GaA

MultiMed®5 MultiMed® MultiMed® MultiMed® MultiMed® M300 / TruSt 1,5m/2.5m 6 plus plusOR 12 M540/IACS Telemetrie

SinglePinconnector

MP03401 ECG 3-lead, IEC1 x (a) x (a) x x x x

MP03402 ECG 3-lead, IEC2 x (a) x (a) x x x x

MP03403 ECG 5-lead, IEC1 x (a) x (a) x x x x

MP03404 ECG 5-lead, IEC2 x (a) x (a) x x x x

MP03405 ECG 6-lead, IEC1 x (a) x x x x

MP03406 ECG 6-lead, IEC2 x (a) x x x x

MP03407 ECG 4-lead C, IEC1

MP03408 ECG 4-lead C, IEC2

DualPinConnector

MP03411 ECG 3-lead, IEC1 x x

MP03412 ECG 3-lead, IEC2 x x

MP03413 ECG 5-lead, IEC1 x x x

MP03414 ECG 5-lead, IEC2 x x x

MP03417 ECG 5-lead C, IEC1 x

MP03418 ECG 5-lead C, IEC2 x

MP03415 ECG 6-lead, IEC1 x

MP03416 ECG 6-lead, IEC2 x

TelemetryGrabbersets

MP03421 ECG 3-lead, IEC1 x x x x

MP03422 ECG 3-lead, IEC2 x x x x

MP03423 ECG 5-lead, IEC1 x x x x

MP03424 ECG 5-lead, IEC2 x x x x

MP03425 ECG 6-lead, IEC1 x x x x

MP03426 ECG 6-lead, IEC2 x x x x

Adapter

MS14679 Adapter MultiMed 5 x

MS14689 Adapter MultiMed 6 x

HF-protectionforOR

5947226 ESU Block MultiMed 5 x

7486140 ESU Block MultiMed 6 x

x (a): can only be connected via adapter

ORDERING INFORMATION

CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germany

www.draeger.com

REGION CENTRAL AND SOUTH AMERICADräger Panama S. de R.L.Complejo Business Park, V tower, 10th floorPanama CityTel +507 377 9100Fax +507 377 [email protected]

Manufacturer:Dräger Medical GmbH Moislinger Allee 53–5523558 Lübeck, GermanyThe quality management system at Dräger Medical GmbH is certified according to ISO 13485, ISO 9001 and Annex II.3 of Directive 93/42/EEC (Medical devices).

REGION EUROPE CENTRAL AND EUROPE NORTHDräger Medical GmbH Moislinger Allee 53–5523558 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION EUROPE SOUTHDräger Médical S.A.S. Parc de Haute Technologie d’Antony 225, rue Georges Besse92182 Antony Cedex, FranceTel +33 1 46 11 56 00Fax +33 1 40 96 97 [email protected]

REGION MIDDLE EAST, AFRICADräger Medical GmbHBranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 [email protected]

REGION ASIA / PACIFICDraeger Medical South East Asia Pte Ltd.25 International Business Park#04-27/29 German CentreSingapore 609916, SingaporeTel +65 6572 4388Fax +65 6572 4399 [email protected]