1 RIP Technology1 RIP Technology
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
����������������������������
����
��
Uncontrolled(natural) electrical field
Capacity-controlledelectrical field
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
������ �������������!���
"!��
�����������
����������
#�$�%���������&�
#�$�����
��$����
�'(���%)
��"���*����
��+�
O I POil ImpregnatedPaper
paper, oil impregn.
yes, on both sides
yes
yes
yes
< 0,007
< 10 pC
O I POil ImpregnatedPaper
paper, oil impregn.
yes, on both sides
yes
yes
yes
< 0,007
< 10 pC
R B PResin BondedPaper
paper, resin bonded
no
no
no
no, only oil-tight
< 0,015
< 250 pC
R B PResin BondedPaper
paper, resin bonded
no
no
no
no, only oil-tight
< 0,015
< 250 pC
R I PResin ImpregnatedPaper
paper, resin impreg.
no
no
no
yes
< 0,007
< 10 pC
R I PResin ImpregnatedPaper
paper, resin impreg.
no
no
no
yes
< 0,007
< 10 pC
#�,���,,'���������� �-.���������
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
������������ �����������
Conductor:- Al, Cu,- solid, tube
Specialcreep paper
Aluminiumfoils
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
������������ �����������
1 Winding process
2 Drying process: - vacuum - heating
3 Under vacuum epoxy resin impregnation process
4 Curing process
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
������������ �����������
5 Machining
6 Assembly 7 Routine Tests
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
� ����� ����������
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
-�+�$�"��������!����*�!/�������������� �
� Simple
� Small
� Reliable
� Safe
� Environmentallyfriendly
SF6 - side ofcopper bar
transformer
side
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
Resin Impregnated Paper - R I P BushingsMain Advantages (1)
HIGH TECHNICAL STANDARD
- Low dielectric losses (tg delta < 0,35%)
- PD free up to double service voltage
- Excellent mechanical strength
- High thermal strength (class E, 120° C)
SUPERB IN DESIGN
- No porcelain shell, except for outdoor use
- Easy adaptable dimensions, customer-tailored bushings
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
Resin Impregnated Paper - R I P BushingsMain Advantages (2)
STORAGE, INSTALLATION AND SERVICE: SIMPLE AND RELIABLE
- Each position allowed (vertical to horizontal)
- Dry, oil - free = simple in handling
ENVIRONMENTALLY FRIENDLY
- Pressure - free = explosion proof, fire resistant
- No pollution by outflowing oil
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
RIP - Technology: summary of main advantages
� Flexible in Design– Adaptable on different transformer and plant constructions– compact & robust– no porcelain except for outdoor
conditions– silicon sheds possible– any installation possible (vertical,
horizontal)� Operation safe, service-friendly
– no damage risk on the bottom part– no explosion risk with influence of the
transformer– gas tight– heavy inflammable– high operation safety also by damages
of outer insulation– no porcelain on transformer side
� Environmental friendly– oil free– no explosion and fire risk through oil
leakage– no environmental risk through oil leakage– maintenance friendly– earthquake proof
� High technical level– excellent mechanical strength– low dielectric losses– partial discharge free up to the double
rated voltage– high thermal strength (120o C)
�������Bushings
fast, professional and creativeMicafil Ltd., Zurich
NEW RIP Transformer BushingsNEW RIP Transformer Bushings
GO WITH US AND GETGO WITH US AND GET
THE MAYOR ADVANTAGETHE MAYOR ADVANTAGE
AGAINST YOURAGAINST YOUR
COMPETITION!!COMPETITION!!
In modern metal enclosed switchgear SF6 - gas is usedas an extinguishing and insulating medium, ensuringhighest security standard for operating staff and resi-dents, especially in most confined and dense populatedareas.As a result, today’s space saving design requires excel-lent mechanical and electrical performance of all com-ponents involved.Micafil’s contribution to this world -wide development isit’s new product range of GARIP bushings. These havebeen designed for the direct single phase connectionbetween power transformers and gas insulated switch-gear (GIS) for rated voltages of 72.5 kV up to 550 kV.
Since more than 40 years Micafil AG produces high vol-tage bushings made with Vacuum Resin ImpregnatedPaper Technology (RIP).We are proud of our leading position in this field, makingavailable to our customers profound expertise in thelatest state of the art technology, which is based uponmore than 50000 RIP - bushings successful in operation.
The insulation body of the GARIP condenser bushingseries consists of a robust and solid core, made ofwound crepe paper and inserted aluminium foils for fieldcontrol, carefully vacuum dried and subsequentlyimpregnated with special epoxy resin.
The basic procedure for this new kind of manufacturewas originally developed by Micafil AG in Switzerlandalready in 1958 and continuously improved in the courseof four decades.
Advanced standardisation, highly skilled craftsmanshipand computer-aided engineering guarantee today’smost reliable and advanced insulation system for everyvoltage level.
Main advantages of Micafil’sRIP- technology
• Short delivery times
• Low dielectric losses (tan δ ~ 0.35%)
• Partial discharge free up to double service voltage
• Fully dry, maintenance free
• Oil - free and environmental friendly
• Highest mechanical and thermal properties
• Robust design and vandalism resistant
• Option for any operating position
• Gas and oil tight
• Easy handling
RIP - Technology for SF6 /Oil - Bushings
2
Technical Data and Dimensions
4
RTKG 362-1300 / 2000RTKG 420-1550 / 2000RTKG 525-1800 / 2000
RTKG 72.5 -350 / 2000RTKG 72.5 -350 / 2500RTKG 123-550 / 2000RTKG 123-550 / 2500RTKG 145-650 / 2000RTKG 170-750 / 2000
RTKG 245-1050 / 2000RTKG 245-1050 / 2500
View A:SF6 side
View A:SF6 side
View B:Oil side
View B:Oil side
RTKG 170-750 / 2500
Flange dimensions for:D13D14
D10D9
D8
D2D5
Test tap
n11 x Øw
n11 x Øwn11 x Øwn11 x Øw
n3 x Øv
n3 x Øvn3 x Øvn3 x Øv
M12 (2 x180°)
M12 (2 x180°)M12 (2 x180°)M12 (2 x180°)M12 (2 x180°)M12 (2 x180°)M12 (2 x180°)
M12 (2 x180°)
Groundedlength
Copper,thickness 30 mm
De-aeration of transformeropposite to test tap
De-aeration of transformeropposite to test tap
Sealing areaRa =1.6 (N7)
Aluminium,silver plated
4 x M1225 deep
Sealing areaRa = 3.2 (N8)
22.5°
15° 30°15° 30°
22.5°11.5° 22.5°11.5°
22.5°11.5°
45°
22.5°45°
22.5°45°
D7
Ø18
d4d5d6
D1
40
s1s2
20L6
2011
5
c6D
4
D3 D4
D3
D4
D3
D4
D3
D12
D11
D12
D11D12
D11
D12
D11
L16
LFL2
L
20
85
80A
B
Dimensiondrawing
Flangedimensions for:
Types 123kV - 245 kV
Types 362kV - 525 kV
Shields removable
prospectus No. D 4352 E
R = RIP InsulationT = Transformer applicationK = Short oil side partG= SF6 -gas application
Nominal current (A)
General Informations
6
Conductor loadingRated current dependent on the bushing lower length(see "Technical Data" page 5 & 6, column 12).Bushings selected with Ir not less than 120% of the ratedcurrent of the transformer are considered to be able towithstand the overload conditions according to IECPublication 60354 (Loading guide).
Recommendations for bushing installationTransformerThe field strength in the oil on the surface of the shieldinsulation must be limited to values normal for insulatedcomponents. As a guideline minimum distances A togrounded transformer parts are given below:
Bushing type
GARIP RTKG 72.5 -350 / 2000
GARIP RTKG 72.5 -350 / 2500
GARIP RTKG 123-550 / 2000
GARIP RTKG 123-550 / 2500
GARIP RTKG 145-650 / 2000
GARIP RTKG 170-750 / 2000
GARIP RTKG 170-750 / 2500
GARIP RTKG 245-1050 / 2000
GARIP RTKG 245-1050 / 2500
GARIP RTKG 362-1300 / 2000
GARIP RTKG 420-1550 / 2000
GARIP RTKG 525-1800 / 2000
Catalogue no.
HLJM 154484
HLJM 154964
HLJM 154504
HLJM 154514
HLJM 154524
HLJM 154534
HLJM 154544
HLJM 154554
HLJM 154564
HLJM 154574
HLJM 154584
HLJM 154594
TypeRTKG
123
145
170
245
362
420
525
A(mm)
130145
170200
210230
300
400
450500
550600
A
AC testvoltage (kV)
185230
275310
325365
460
570
630680
750790
Type designationThe type designation is included in an overall system. Anexample of nomenclature used to designate our GARIPbushings:
GARIP RTKG 245-1050 / 2000
Testing of the bushingEach bushing undergoes routine testing before leavingthe factory, either according to IEC 60137 or IEEEC57.19.00.
The standard tests include:
• Tan δ, capacitance and partial discharge measure-ment
• Power frequency test• Lightning impulse test (if applicable)• Leakage test
Ordering particularsWhen ordering please state:
• Type and catalogue no. see the table below• CT space L6, see "Technical Data" page 5 & 6, column
20• For 170 kV / 2000 A respective 245 kV / 2000 A only:
choose the size of oil side shield depending on thetransformer current; see "Technical Data" page 5 & 6,columns 26 &27
Lightning impulsevoltage (kV)
Rated voltage (kV)
Bushing series
GISObserve the minimum enclosurediameter DGIS as well as the minimumoperating SF6 - gas pressure (see"Technical Data" page 5 & 6, columns17 & 18). Adjacent conductor parts shouldbe well adapted to the bushing terminal.
GeneralBecause the bushing is completely dry it can beoperated vertically or horizontally or in any position.