Replacement Parts List No. 700051300 Revision I 02/2018 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com Daikin Roofpak™ Applied Rooftop Units Inverter Compressor Models RPS, RDT 045 - 074 Tons Vintage D Code 44= V, W
Transcript
Page 1: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Replacement Parts List No. 700051300 Revision I 02/2018

To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Daikin

Roofpak™Applied Rooftop Units

Inverter Compressor ModelsRPS, RDT

045 - 074 TonsVintage D

Code 44= V, W

Page 2: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 2

ContentsParts List Revision History ...................................................................................................................................................... 5Nomenclature Unit Model and Serial Number ........................................................................................................................................... 6 Unit Code Index ............................................................................................................................................................7- 12 Control & Sensor Location Diagrams ............................................................................................................................... 13Electrical Legend .............................................................................................................................................................. 14- 17Section A1- Outdoor/Return Air Section Notes ............................................................................................................................................................................... 18 100% Outside Air Damper with Hood- No Return Air Plenum .......................................................................................... 19 100% Outside Air Damper Detail w/ACT3 ....................................................................................................................... 20 0- 30% Outside Air Section w/ ACT3 ................................................................................................................................ 21 0- 100% Economizer Section with Barometric Exhaust Damper- Units w/o Return Air Fans .......................................... 22 0- 100% Economizer Section with Barometric Exhaust Damper- Units w/ 40” Return Air Fans ...................................... 23 0- 100% Economizer Section with Prop Exhaust Fan & Damper .................................................................................... 24 0- 100% Economizer Damper w/ ACT3- Diagrams ......................................................................................................... 25 0- 100% Economizer Damper w/ ACT3- Components ..................................................................................................... 26 California Title 24 Assembly: Code 33= *F*** ................................................................................................................... 27 Return Air Plenum Isolation Damper w/ Actuator ACT6 .................................................................................................. 28 Prop Exhaust Fan & Damper .................................................................................................................................... 29, 30 Design Flow Detail ........................................................................................................................................................... 31 40” Return Air Fan: Code 21= 40B* ................................................................................................................................. 32 Return Air Fan Fan Mounts: Code 21= 40B* ................................................................................................................... 33 Return Air Fan Motors ................................................................................................................................................ 34, 35 Section Mounted Controls- OAE, RAE, LT11, S11, REC11 .............................................................................................. 36Section A2- Outdoor/Return Air w/ Heat Recovery Section Notes ............................................................................................................................................................................... 37 Cabinet Gaskets, Doors, Hardware, Exhaust Hoods ....................................................................................................... 38 Base Components, Hood, Dampers................................................................................................................................. 39 40” Return Air Fan: Code 21= 40B* ........................................................................................................................... 40, 41 Low Leak Damper Detail ................................................................................................................................................. 42 Bypass “L” Type Damper Detail ....................................................................................................................................... 43 Heat Recovery/Enthalpy Wheel, Motor, Drive Components, Seals.................................................................................. 44 AFD60 Frost Protection Inverter: Code 24= F ................................................................................................................. 45 Section Mounted Controls- OAE, RAE, RAT, EAT, LAT .................................................................................................... 46 Section Mounted Controls- SD2, HUM1, LT11, S11, REC11 ........................................................................................... 47Section B- DrawThru Filter/Blank Section Notes ................................................................................................................................................................................ 48 Section Mounted Controls- PC5, LT13, S13, REC13 ...................................................................................................... 48 Filters ................................................................................................................................................................................ 49 Air Blender Section Components .................................................................................................................................... 50 Magnehelic/Differential Pressure Gauges ....................................................................................................................... 50Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes ............................................................................................................................................................................... 51 Section Mounted Controls- LT21, S21, REC21 ............................................................................................................... 51Section D- DrawThru Cooling Section Notes ............................................................................................................................................................................... 52 24” Section, Small Face Coils .......................................................................................................................................... 53 48” Section, Large Face Coils .......................................................................................................................................... 53Section E- Spacer Section & Section E- DrawThru Heat Section Notes ............................................................................................................................................................................... 54 Section Mounted Controls- LT18, REC18, S18- Section Mounted Light ......................................................................... 54 Hot Water OR Steam Coil Heat, Mixing Valves & Actuator VM1 ...................................................................................... 55 Section F- Supply Air Section Notes ............................................................................................................................................................................... 56 Air Foil Fan- Double Width- RPS Units ............................................................................................................................ 57 Air Foil Fan- Single Width- RDT Units ............................................................................................................................. 58 Fan Mounts- 27” Airfoil Double Width Fan ..................................................................................................................... 59 Fan Mounts- 30” Airfoil Double Width Fan ...................................................................................................................... 60 Fan Mounts- 33” Airfoil Double Width Fan ....................................................................................................................... 61 Fan Mounts- 40” AFSW- RDT Units ................................................................................................................................. 62 Fan Mounts- 44” AFSW- RDT Units ................................................................................................................................ 63 Supply Air Fan Motors ............................................................................................................................................... 64, 65 Belt Guards ...................................................................................................................................................................... 66

Page 3: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 3

ContentsContinued

Section F- Supply Air Section, Continued Inverters & Inverter Bypass Control Box Motor HP 2- 5 .............................................................................................................................................................. 67 Motor HP 7.5- 25 ................................................................................................................................................... 68, 69 Motor HP 30- 50 .................................................................................................................................................... 70, 71 Inverters ................................................................................................................................................................ 72- 76 Line Reactors .............................................................................................................................................................. 77 Section Mounted Controls- PC7, HL22, LT10, S10, REC10, UV Lights ........................................................................... 78 Section Mounted Controls- MAT, EFT, SAT, DAT, OAT, SD1 ............................................................................................ 79 Section Mounted Controls- SCB- Split Junction Box- TB25, TB27, TB28, PB10, PB9, PB20, PB19 .............................. 80Section G- BlowThru Heat Section Notes ............................................................................................................................................................................... 81 Option 1: Blank/Empty Section Diffuser ........................................................................................................................................................................ 81 Option 2: Hot Water OR Steam Coil Heat Mixing Valves and Actuator VM1 ................................................................................................................................. 82 Option 3: Electric Heat Heaters, Diffusers, Hi Limit Cutouts HL1- 20, 31- 50 ............................................................................................ 83, 84 Electric Heat Control Box ..................................................................................................................................... 85- 89 Option 4- Gas Heat Heat Exchangers & Vestibules- 200, 250 MBH Furnaces .......................................................................................... 90 Heat Exchangers & Vestibules- 320, 400, 500, 640, 650, 790, 800, 1000 MBH Furnaces ........................................ 91 Modulating Burner ................................................................................................................................................. 92- 94 Hi Turn Down Burner ............................................................................................................................................ 95- 98 Modulating Burner Controls- MicroTech III Controls ................................................................................................... 99 Hi Turn Down Burner Controls- MicroTech III Controls ............................................................................................. 100 Gas Train- Inlet .................................................................................................................................................. 101-103 Gas Train- Controls: GV1,GV2, GV3, GV4, GV5, GV6, VM1 ........................................................................... 104- 106 Gas Train- Outlet ...................................................................................................................................................... 107 Gas Train- Damper Linkage ..................................................................................................................................... 108 Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting ......................................................................... 109, 110Section H- BlowThru Heat Blank Access Section Notes .............................................................................................................................................................................. 111 Access Door Latching Assemblies, Key, & Lock (All Sections) ...................................................................................... 111Section I- BlowThru Cooling Section Notes .............................................................................................................................................................................. 112 Section Mounted Controls- LT16, S16, REC16 .............................................................................................................. 112Section J- Final Filter Section Notes .............................................................................................................................................................................. 113 Section Mounted Controls- HL23, PC6 .......................................................................................................................... 113 Filters ...................................................................................................................................................................... 114, 115Section K- Discharge Plenum Section- (RPS) Notes .............................................................................................................................................................................. 116 Section Mounted Controls- OAT, DAT, SD1 .................................................................................................................... 116 Discharge Damper Assembly w/ Actuator ACT5 ............................................................................................................ 117Section L- Out-of-Airstream Blank Access Section Notes .............................................................................................................................................................................. 118 Section Mounted Controls- LT20, REC20, S20 .............................................................................................................. 118Section M- Condenser Section Notes .............................................................................................................................................................................. 119 Condenser Fan Deck Assembly: Code 47= 2 ....................................................................................................... 120, 121 Quiet Fan Assembly: Code 47= 4 ................................................................................................................................. 122 Compressors & Compressor Components: Code 44= V, W Compressors Circuit #1 ............................................................................................................................................. 123 Compressors Circuit #2 ............................................................................................................................................. 124 Inverter Compressor Components ............................................................................................................................ 125 Compressor Mounting Components ......................................................................................................................... 126 Condenser Coil Guards ............................................................................................................................................. 127 Pressure Controls Box ........................................................................................................................................... 128, 129 Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C ............................................................................... 130 Inverter Compressor Control Box .................................................................................................................................. 131

Page 4: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 4

ContentsContinued

Section N- Main Control Box Notes ............................................................................................................................................................................. 132 Control Box Component Label Diagram......................................................................................................................... 133 Control Panel MicroTech III Units with Controller: Code 12= *E, *F, *W- Diagram .......................................................................... 134 MicroTech III Units with Controller: Code 12= *E, *F, *W- Components ............................................................ 135, 136 Power Panel Power Panel Diagram ............................................................................................................................................... 137 Terminal Blocks, T1 Transformer & Fusing ............................................................................................................... 138 Fusing, Phase Protection, Ground Fault, Power Blocks ........................................................................................... 139 Power Blocks, continued, Receptacle, Plugs ........................................................................................................... 140 Disconnect Switch DS1, 2 ........................................................................................................................................ 141 Supply MMP10 & M10 Fan Contactor, Return MMP20 & M20 Fan Contactor Diagrams ........................................ 142 Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components .................................................. 143- 149 Compressor Motor Protector MMP1, 3, 5 & Contactor M1, 3, 5 Unit Size 045D ..................................................................................................................................................... 150 Unit Size 050, 051D ............................................................................................................................................. 151 Unit Size 063D ..................................................................................................................................................... 152 Unit Size 074D .................................................................................................................................................... 153 Inverter Compressor Fuseblock & Fuse Components FB2M .................................................................................... 154 SpeedTrol Condenser Fan Fusing: Code 47= 2, 4 ................................................................................................... 155 Energy Recovery Wheel Contactors, MMPs, & Fusing ............................................................................................ 156 Intelligent Equipment ...................................................................................................................................................... 157 Section O- Refrigeration Tubing Notes ............................................................................................................................................................................. 158 Refrigeration Tubing Diagram ........................................................................................................................................ 158 Valves, Filter Driers, Sight Glasses ........................................................................................................................ 159, 160 Hot Gas Reheat.............................................................................................................................................................. 161

Page 5: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 5

Parts List Revision History Rev. Date Description New 03/16 New. Used form #7000137 Rev. AK as a starting point. A 04/16 Page 124: Added Sightglass and gasket p/ns & dwg. B 04/16 Page 82: Added Freezestat FS1 p/n “072502001”. C 06/16 Page 4: Changed “Intelligent Design” to “Intelligent Equipment”. Page 99: Updated Ref. #34 TB11 p/ns & qtys. Page 119: Rewrote Notes. Page 121: Deleted Coil Guard p/ns. Moved info. to NEW pg. 127. Added footnotes. Page 122: Added footnote # 2. Page 124: Added 575V Compressors. Deleted footnote # 2. Page 127 (NEW): Added pg. for updated Condenser Coil/Vandal guards. Repaginated the form & updated the TOC. Page 134 (OLD) 135 (NEW): Added MTIII Remote Keypad & Remote Interface p/ns. Page 156 (OLD) 157 (NEW): Rewrote notes for IE. Added coding to pg. header. Updated dwg. D 06/16 Page 17: Added TB35- 37 info. Page 128, 129: Added new TB37 p/n for 575V units. Rewrote footnotes & updated TB36, 37 descriptions. E 05/17 Page 7: Rewrote footnote # 1. Page 34, 54: Corrected coding. Page 37: Rewrote Notes. Page 47: Updated HUM1 p/ns. Page 75: Rewrote footnote # 1. Page 99, 100: Added footnote # 1 & footnote notation. Page 111: Updated Latching Assy. descriptions. Rewrote footnote # 2. Page 119: Rewrote Notes. Page 136: Updated/corrected R63 p/ns. Page 155: Updated Ref # 9A Fuse p/ns. Rewrote footnotes and footnote notation. Page 156: Rewrote footnote # 3. Page 160: Updated HGBP p/ns and rewrote footnotes. F 08/17 Page 160: Added Check Vlv. p/ns. Page 161: Updated/corrected table per EPS_5229 Rev T, and deleted footnote # 2. G 09/17 Page 16: Deleted “PVM4”. (RCS units only.) Page 139: Added 1/17 & Later PVM components. Corrected qtys. H 10/17 Page 125: Added Sight Glass/Prism p/n, Bub., & footnote # 1. I 02/18 Page 135: Deleted OBS 193408001 Display. Combined with Remote Keypad 193408003.

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Page 6: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 6

NomenclatureUnit Model and Serial Number

R P S 050 D AUnit Model Number

Roofpak: R= Roofpak Applied Rooftop

Unit Configuration P= Heating, mechanical cooling D= Heating, mechanical cooling, DrawThru

Zone S, T= Singlezone Unit

Nominal Capacity (Tons) Ex. 050= 50 Tons

Design Vintage

Heating Medium A= Natural Gas E= Electric S= Steam W= Hot Water Y= None (cooling only)

FBO U 15 10 048120Plant Identification AbbreviationFBO = Faribault, MN

Serial Number (build sequence)

U= UnitYear of Manufacture14= 2014, 15= 2015, 16= 2016, 17= 2017, etc.

Month of Manufacture01= Jan.02= Feb.03= Mar.

04= Apr.05= May06= Jun.

07= July08= Aug.09= Sept.

10= Oct.11= Nov.12= Dec.

Serial Number

Page 7: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 7

NomenclatureUnit Code Index 1

General OptionsUnit Model Codes that Pertain: 03, 05, 06, 07, 33, 61- 72

Auxiliary Controls/Remote SensorsUnit Model Codes that Pertain: 12, 13, 16, 17, 18

Sections A1, A2Return/Outside Air/Heat Recovery OptionsUnit Model Codes that Pertain: 19, 20, 21, 22, 24, 58

Sections B, C, D, EDrawThru Cooling SectionsSection B- Filter SectionUnit Model Codes that Pertain: 25, 33, 50

Section C- DrawThru Blank AccessUnit Model Codes that Pertain: 26, 14, 15

Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 03, 27, 28

Section E- Spacer Section (RPS)Unit Model Codes that Pertain: 04, 30

Section E- DrawThru Heating Section (RDT)Unit Model Codes that Pertain: 04, 30

Section F- Supply Fan OptionsUnit Model Codes that Pertain: 31, 32, 59, 08, 14, 15, 40, 49

Sections G, H, IBlowThru OptionsSection G= BlowThru Heat/Blank AccessUnit Model Codes that Pertain: 04, 34

Section H= BlowThru Blank AccessUnit Model Codes that Pertain: 34, 38

Section I- BlowThru Cooling SectionsUnit Model Codes that Pertain: 03, 35, 36

Section J- Final Filter SectionUnit Model Codes that Pertain: 39

Section K- Discharge Plenum SectionUnit Model Codes that Pertain: 40

Section L- Out-of-Airstream Blank Access SectionUnit Model Codes that Pertain: 41

Section M- Condenser SectionUnit Model Codes that Pertain: 09, 23, 43, 44, 45, 47

Section N- Main Control PanelUnit Model Codes that Pertain: 08, 09, 11, 12, 13, 14, 15, 16, 17, 18, 23

Section O- Refrigeration TubingUnit Model Codes that Pertain: 45, 46, 54

RPS 050D S W Y 1 EY D 27 AL P1 LE 1 1 A 3 CD S120 BY DE 40B2 JEY Code 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22

YYAYA Y AH Y CYYS 4Z083D YYYYYY YYYYYY 30A2 LEY YYYYY W11E3E 23 24 25 26 27 28 29 30 31 32 33 34

CYYS 4Z083D YYYYYY Y Y BY Y M TY V 1 1 2 Y D Y 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

EEEEEE YY YY YY YY YY YY 0987A 1252A XX 1 A A Y 047C 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65

Y Y YY YYYYYYYY 66 67 68 69- 72

1 An "X" located in Code 60 in a code string indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas with the EXCEPTION of special text that ONLY indicates the presence of variable speed scroll compressors. So, in cases where sections of the unit have special features (not strictly related to the presence of inverter compressors), it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s).

Page 8: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 8

Code 03= Cooling Coil S= Small L= Large

Code 04= Heat Type A= Natural Gas E= Electric S= Steam W= Hot Water Y= None

Code 05= Unit Split F= Fan/Heat Y= None

Code 06= Insulation and Liners 1= 1”, 3/4# with liners on doors 2= 1½”, 1½# with solid liners on doors & ceilings 3= 1½”, 1½# with perforated liners in plenums, solid elsewhere 4= 1½”, 1½# with solid liners on doors, ceilings and floors 5= 1½”, 1½# with perforated liners in plenums, solid elsewhere (including floors) 6= 1½”, 1½# with SS Solid Liners on doors, ceilings and floors

Code 07= Approval Agency Listing CC, CD, CY= ETL Canada EM, EU, EY, YU= ETL/MEA- USA YY= None

Code 08= Main Control Box Location D= Discharge Plenum (RPS) F= Supply Fan Section (RDT)

Code 09= Unit Voltage 12= 208/60/3 29= 230/60/3 27= 460/60/3 37= 575/60/3

Code 10= Starting Option AL= Across- The- Line

Code 11= Field Power Connection and Disconnect P1= Single Power Block: Complete Unit Q1= Two Power Blocks: EH/Balance of Unit R1= Two Power Blocks: Fans & Controls/Balance of Unit A2= One, thru-the-door Disconnect: Complete Unit C2= Two, thru-the-door Disconnects: SAF&RAF&CB/Balance of Unit B2= Two, thru-the-door Disconnects: EHB/Balance of Unit D2= Three thru-the-door Disc.: EH/SAF&RAF&CB/Balance of Unit

Code 12= Temperature ControlsMicroTech III Controls Digit 1: Communication Type L= LonWorks B= BACNet w/MSTP E= BACNet w/Ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit 2: Control Type E= Discharge Air w/ Static Pressure Control F= Space OR Zone Ctl. W= Discharge Air w/ Space Control

NomenclatureUnit Code Index, Continued

Code 13= Air Flow Controls Y= None 1= 1 Duct Sensor 2= 2 Duct Sensors 3= 1 Duct and 1 Space Sensor 4= 1 Space Sensor Code 14= Inverters Y= None Separate Section 1= SA Fan only w/ Bypass 2= SA & RA Fans w/ Bypass 4= RA only w/ BypassNo Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan w/o Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan w/o Bypass

Code 15= Inverter Brand Y= None A= ABB Inverter G= Graham Inverter Q= Schneider Inverter R= Reliance Inverter S, B= Daikin Applied Inverter F= Field Installed Inverter controlled by MicroTech

Code 16= Smoke Detectors Y= None 1= Return Air Fan Section 2= Supply Air Fan Section 3= (RAF) + (SAF)

Code 17= Misc. Aux. ControlsC G

Y= NoneF= Freezestat (Steam OR HW Heat only)P= Phase FailureG= Ground Fault ProtectionL= Line Reactors (Inverter w/ separate section only)A= Freezestat & Phase Failure (Steam OR HW Heat only)B= Freezestat & Ground Fault (Steam OR HW Heat only)C= Phase Failure & Ground FaultD= Freezestat, Phase Failure & Ground Fault (Steam OR HW Heat only)E= Freezestat & Line Reactors (ST/HW Heat & Inverter w/separate section only)H= Phase Failure & Line Reactors (Inverter w/ separate section only)J= Freezestat, P.F. & Line Reactors (ST/HW Heat & Inverter w/separate section only)K= Ground Fault, Phase Failure & Line Reactors (Inverter w/ separate section only)1= UV Lights2= UV Lights + F3= UV Lights + P4= UV Lights + L5= UV Lights + A6= UV Lights + E7= UV Lights + H8= UV Lights + J

C= Differential EnthalpyY= None (includes mechanical enthalpy)

Code 18= Misc. Controls/ Unit Length A, S, Y___= None (___= Air Handler Length [in.]) R___= Remote Keypad (___= Air Handler Length [in.])

Code 19= Return Air Plenum YY= No section BY= Bottom Return BB= Bottom Return w/Burglar Bars BE= Bottom Return w/Isolation Damper HY= Back Return LY= Left Return SY= Side Return

Page 9: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 9

NomenclatureUnit Code Index, Continued

Code 20= Outdoor Air Options YY= None AE= 100% Outside air Damper w/ Hood & Actuator AY= 100% Outside air damper w/ Hood w/o Actuator BE= 0- 30% Outdoor air section w/ Actuator BY= 0- 30% Outdoor air section w/o Actuator DE= 0- 100% Econ. w/ barometric exhaust Damper w/ Act. DY= 0- 100% Econ. w/ barometric exhaust Damper w/o Act. EE= 0- 100% Econ. w/ power closure exhaust Damper w/ Act. EY= 0- 100% Econ. w/ power closure exhaust Damper w/o Act. HE= 0- 100% Econ. w/ prop exhaust Damper w/ Act. HY= 0- 100% Econ. w/ prop exhaust Damper w/o Act. FE= same as DE + Design Flow FY= same as DY + Design Flow GE= same as EE + Design Flow GY= same as EY + Design Flow JE= same as HE + Design Flow JY= same as HY + Design Flow KE= same as DE + Ebtron Sensor KY= same as DY + Ebtron Sensor LE= same as EE + Ebtron Sensor LY= same as EY + Ebtron Sensor ME= same as HE + Ebtron Sensor MY= same as HY + Ebtron Sensor 3E= Energy Recovery Economizer, Low CFM- 6” wheel 4E= Energy Recovery Economizer, Low CFM- 12” wheel 5E= Energy Recovery Economizer, High CFM- 6” wheel 6E= Energy Recovery Economizer, High CFM- 12” wheel

Code 21= Return Air Fan YYYY= No Return Air Fan 40B()= 40” Airfoil Single Width ()= Isolator type: 1= Rubber-in-Shear (RIS) 2= Spring 3= Spring w/ seismic restraints

Code 22= Return Air Fan Motor YYY= No Return Fan J E Y

Y= NoneS= Shaft Ground Kit

E= High Eff. ODP motorH= High Eff. Totally-EnclosedJ= Premium Eff. ODPK= Premium Eff. Totally-Enclosed

G= 2.0 HPH= 3.0 HPJ= 5.0 HPK= 7.5 HP

L= 10.0 HP Q= 30.0 HPM= 15.0 HP N= 20.0 HP P= 25.0 HP(prop exhaust option is always J [5.0 HP])

Code 23= Miscellaneous Electrical Options Digit 1: UV Lights Y= NoneDigit 2: Plenum/Vestibule Lights Y= NoneDigit 3: SpeedTrol, Energy Recovery, HGRH Inverter Y= None A= ABB B= Daikin Applied Q= SchneiderDigit 4: 115V Service Outlet Y= Field Supplied 115V Power, Outlet by Factory F= Factory supplied Line Voltage & OutletDigit 5: Intelligent Equipment/IE Y= None A= Intelligent Equipment (IE)

Code 24= Exhaust Fans OR Frost Protection Y= None 1= 1 Prop Exhaust Fan w/ Hood 2= 2 Prop Exhaust Fans w/ Hood F= Heat Recovery Frost Protection Inverter

Code 25= DrawThru Filter SectionDigit 1: Section Type A= 2” Angular (24” Section) F= Flat (24” Section) G= 4” Angular- 24” section L= Large Staggered- 48/24” section S= Staggered- 48” section D= Blank 24” section E= Blank 48” sectionDigit 2: Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/Intersept H= Throwaway 85% Efficient D= Cartridge 65% Efficient (w/ 2” Prefilters) E= Cartridge 95% Efficient (w/ 2” Prefilters) G= Cartridge 95% Efficient w/Intersept (w/ 2” Prefilters)

Code 26= Blank DrawThru Section Y= No section E= Blank 24” Section F= Blank 48” Section

Code 27= DrawThru Drain Pan/Cooling Coil SectionDigits 1- 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only (48” section) GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits 1- 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits 1- 3= DYY only)

Page 10: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 10

NomenclatureUnit Code Index, Continued

Code 29= DrawThru Heating CoilYYYYYY= No Heating Coil

Code 30= DrawThru Heating Section (RDT only)OR Blank Spacer Section (RPS only)YYYYYY= No Heating SectionEEEEEE= Blank 24” SectionFFFFFF= Blank 48” Section

Hydronic Heat (RDT only)W22 J 3 E

2= 2 Way Steam Valve Y= No Valve3= 3 Way HW Valve

E= 1¼” Valve Pkg. H= 2½” Valve Pkg.F= 1½” Valve Pkg. J= 3.0” Valve Pkg.G= 2.0” Valve Pkg. Y= No Valve Pkg.

S11= 5JA0601H (6FPI, 1 Row 5J Steam Coil)S12= 5JA1201H (12FPI, 1 Row 5J Steam Coil)S13= 5JA0602C (6FPI, 2 Row 5J Steam Coil)S14= 5JA1202C (12FPI, 2 Row 5J Steam Coil)W11= 5WH0901H (9FPI, 1 Row 5WH HW Coil)W22= 5WS0902C (9FPI, 2 Row 5WS HW Coil)

E= Electric ActuatorY= Less Actuator

Always ‘Y’

1= 1 Stage 2= 2 Stages 4= 4 Stages 6= 6 Stages

E020= 20 KW Heater E200= 200 KW HeaterE040= 40 KW Heater E240= 240 KW HeaterE060= 60 KW HeaterE080= 80 KW HeaterE100= 100 KW HeaterE120= 120 KW HeaterE160= 160 KW Heater

Electric Heat (RDT only)E020 1 Y

Code 31= Supply Air Fan 27A()= 27” Airfoil Double Width (RPS only) 30A()= 30” Airfoil Double Width (RPS only) 33A()= 33” Airfoil Double Width (RPS only) 40B()= 40” Airfoil Single Width (RDT only) 44B()= 44” Airfoil Single Width (RDT only) ()= Fan Isolators 1= Rubber-in-Shear (RIS) 2= Spring 3= Spring w/Seismic Snubbers

E= High Eff. ODP motor H= High Eff. Totally-EnclosedJ= Premium Eff. ODP MotorK= Premium Eff. Totally-Enclosed

H= 3.0 HP M= 15.0 HP R= 40.0 HPJ= 5.0 HP N= 20.0 HP S= 50.0 HPK= 7.5 HP P= 25.0 HP L= 10.0 HP Q= 30.0 HP

Code 32= Supply Air Fan MotorK E Y

Code 34= Blow Thru Heat Section (RPS only)YYYYYY= No section, cooling onlyBBBBBB= Blank 48” section, no heat, cooling only

E= Modulating BurnerR= Modulating Burner/with H.P. Regulator Range= 2-3 psiS= Modulating Burner/with H.P. Regulator Range= 5-10 psiH= Hi Turn Down Burner 20:1T= Hi Turn Down Burner 20:1/with H.P. Regulator Range= 2-3 psiU= Hi Turn Down Burner 20:1/with H.P. Regulator Range= 5-10 psi

S= Stainless Steel Heat Exchanger

MBH (in 10’s)ex. 020= 200 MBH [020,025,032,040,050,064,065,079,080,100]

Gas Heat Breakdown:020 S S C

A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position

2= 2 Way Steam Valve 3= 3 Way HW Valve

E= 1¼” Valve Pkg. H= 2½” Valve Pkg.F= 1½” Valve Pkg. J= 3.0” Valve Pkg.G= 2.0” Valve Pkg. Y= No Valve Pkg.

S11= 5JA0601H (6FPI, 1 Row 5J Steam Coil)S12= 5JA1201H (12FPI, 1 Row 5J Steam Coil)S13= 5JA0602C (6FPI, 2 Row 5J Steam Coil)S14= 5JA1202C (12FPI, 2 Row 5J Steam Coil)W11= 5WH0901H (9FPI, 1 Row 5WH HW Coil)W22= 5WS0902C (9FPI, 2 Row 5WS HW Coil)

E= Electric Actuator

Hydronic Heat Breakdown:W22 J 3 E

3= 3 Row 5= 5 Row4= 4 Row 6= 6 Row

08= 8 Fins-per-inch10= 10 Fins-per-inch12= 12 Fins-per-inch14= 14 Fins-per-inch

4Z= Type 4EZ

D= Lanced AluminumC= Hi-F Copper w/ SS casing

Code 28= DrawThru Cooling Coil YYYYYY= No Cooling Coil4Z 08 3 D

Code 33= Miscellaneous Mechanical OptionsDigit 1: Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DT & BT sectionsDigit 2: California Title 24 Y= None F= Economizer w/ Fault Detection/Diagnosis (FDD) Digit 3: Ebtron Air Flow Y= None S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold)Digit 4: Heating Coil Options Y= None E= Electrofin CoatingDigit 5: Cooling Coil Options Y= None E= Electrofin Coating

Y= NoneS= Shaft Ground Kit

Page 11: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 11

NomenclatureUnit Code Index, Continued

Code 37= N/A to RPS/RDT- Always YYYYYY

Code 38= Attenuator Section (RPS only) Y= No section G= With 36” Std. Straight Attenuator K= With 36” Std. Straight Attenuator w/ Tedlar Coating H= With 60” Std. Straight Attenuator L= With 60” Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating F= Blank 48” Section E= Blank 24” Section

Code 39= Final Filter Section (RPS only) Y= No section A= Flat filter section, 95% cartridge, 24/24” section J= Flat filter section, 95% cartridge, 24” section B= Staggered filter section, 95% cartridge, 24/48” section K= Staggered filter section, 95% cartridge, 48” section E= Flat filter section, 95% cartridge w/ Intersept, 24/24” section L= Flat filter section, 95% cartridge w/ Intersept, 24” section F= Staggered filter section, 95% cartridge w/ Intersept, 24/48” section M= Staggered filter section, 95% cartridge w/ Intersept, 48” section G= Flat filter section, 95% HEPA cartridge, 24/48” section N= Flat filter section, 95% HEPA cartridge, 48” section H= Flat filter section, 95% cartridge, 48/48” section Q= Blank- 24/24” section R= Blank- 24/48” section S= Blank- 24” section T= Blank- 48” section

Code 40= Discharge Plenum BY= Bottom Discharge BB= Bottom Discharge w/ Burglar Bars BE= Bottom Discharge w/ Discharge Damper LY= Left Side Opposite Side RY= Right Side Drive Side

Code 41= Out-of-Airstream Blank Access Section Y= None 1= 48/24” Blank Section only- out of airstream with light 2= 48” Blank Section only- out of airstream with light

Code 42= Compressor Capacity Control M= Modulating

Code 43= Condenser OptionsDigit 1: Air Coil M= 25mm Micro Channel Coil P= 25mm Electrofin Coated Micro Channel Coil T= 32mm Micro Channel Coil U= 22mm Electrofin Coated Micro Channel Coil Y= NoneDigit 2: Condenser Options G= Coil Guards, Steel S= Seal Tite Conduits B= G + S Y= None

Code 44= Compressor Type V= Variable Speed Scroll W= Variable Speed Scroll w/ Line Reactor

Code 45= Compressor Isolation 1= Resilient Rubber-in-Shear Code 46= Piping Options 1= Hot Gas Bypass, circuit #1 only 2= Hot Gas Bypass, cir. 1 & 2 3= Replaceable Filter Drier Core 4= 1 + 3 5= 2 + 3 Y= None Code 47= Low Ambient Operation 2= SpeedTrol Standard Fans L= Low Ambient 4= Quiet Fan + SpeedTrol Code 48= IBC Seismic Construction Y= None A= ASCE 7- 10 Wind Certification I= Seismic Construction J= IBC Seismic Construction- Category E/F

Code 49= Fan Section Options A= SA Fan Belt Guard E= SA & RA Fan Section Light B= SA Fan Section Light F= D + E C= A + B Y= None D= SA & RA Fan Belt Guard

Code 50= Blender Section Y= None L= Low CFM Blender, 48” Section H= High CFM Blender, 48” Section E= Blank 24” Section F= Blank 48” Section

Code 34= Blow Thru Heat Section, Continued

Always ‘Y’

1= 1 Stage 2= 2 Stages 4= 4 Stages 6= 6 Stages

E020= 20 KW Heater E120= 120 KW HeaterE040= 40 KW Heater E160= 160 KW HeaterE060= 60 KW Heater E200= 200 KW HeaterE080= 80 KW Heater E240= 240 KW Heater E100= 100 KW Heater

Electric Heat Breakdown:E020 1 Y

Code 35= BlowThru Coil Section/Drain Pan (RPS only) YYYY= No sectionDigits 1- 3 Cooling Type CYY= Cooling unit DYY= Drain Pan only- 48” section GYY= Cooling w/ Hot Gas ReheatDigit 4: Options S= Std. stainless steel Drain Pan P= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits 1- 3= DYY) T= Wide painted galvanized steel Drain Pan (Digits 1- 3= DYY)

3= 3 Row 5= 5 Row4= 4 Row 6= 6 Row

08= 8 Fins-per-inch 12= 12 Fins-per-inch10= 10 Fins-per-inch 14= 14 Fins-per-inch

4Z= Type 4EZ

D= Lanced AluminumC= Copper Fin

Code 36= BlowThru Cooling Coil (RPS only)YYYYYY= No Cooling Coil4Z 08 3 D

Page 12: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 12

Code 60= Miscellaneous Specials YY= None XX= Special

Code 61= Packaging/ASHRAE Certification 1= Steel Skid 2= Consolidated Ship

Code 62= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special

Code 63= Compressor Warranty A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special

Code 64= Heat Exchanger Warranty Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special

Code 65= Unit Family 047C= 045D- 074D

Code 66= Drain Connection Y= None L= Left Side (opposite drive side) R= Right Side (drive side)

Code 67= ASHRAE Certification Y= None B= AHRI Certified-90.1 2010C= AHRI Certified-90.1 2013

Code 68= Short Circuit Current Rating YY= None 10= 10 SCCR 22= 22 SCCR 65= 65 SCCR

Code 69- 72 N/A to RPS/RDT- Always YYYYYYYY

Code 51= Draw=Thru Pre-Heat Section YYYYY= None EEEEEE= Blank 24” Section FFFFFF= Blank 48” Section W 11 E 3 E

Y= No ActuatorE= Electric Actuator

Y= No Valve2= 2- Way Valve (ST)3= 3- Way Valve (HW)

Y= No ValveE= 1.25” Valve J= 3.00” ValveF= 1.50” ValveG= 2.00” ValveH= 2.50” Valve

11= 9 FPI 1 Row (HW) OR 6 FPI 1 Row (ST)12= 12 FPI 1 Row (ST)13= 06 FPI 2 Row (ST)14= 12 FPI 2 Row (ST)22= 9 FPI 2 Row (HW)

W= Hot Water Heat (HW)S= Steam Heat (ST)

Code 52= Drain Pan/Humidifier Section (RPS only) YY= None DH= Humidifier w/ stainless steel Drain Pan 48” section DY= Stainless steel Drain Pan only, 48” section EE= Blank 24” Section FF= Blank 48” Section

Code 53= Custom Specifications YY= None RR= “B” vintage replacement unit Code 54= Hot Gas/Liquid Subcool Reheat YY= None BM= BlowThru Modulating (includes SpeedTrol) ML= Modulating Liquid Subcool Reheat Circuits #1 & 2 BL= BlowThru Modulating, Hot Gas Circuit #2, AND Modulating Liquid Subcool Reheat Circuits #1 & 2

Code 55= Ultra High Efficiency Units YY= None HE= Ultra High Efficiency Unit (051D, 063D)

Code 56= Chicago Code/Refrigeration Service Valves YY= None CC= Chicago Code YV= Refrigeration Service Valves CV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS/RDT- Always YY

Code 58= Return Air Fan Drive Selection_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 59= Supply Air Fan Drive Selection_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

NomenclatureUnit Code Index, Continued

RequiredRPM

RequiredRPM

Page 13: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 13

NomenclatureControl & Sensor Location Diagrams 1

RPS

RDT

Control Locations

1 The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected.

Return aireconomizer

Filtersection

Supplyfan

Heat

DX section

Dischargeplenumsection

Condensorsection

RAT

LT11(optional)

S11,REC11

OAE

ACT3 PC5S10, REC10

LT10HL22

EFT

SD1VM1

DAT ACT5 (optional)

HTR1-2, HTR3-4 (optional)

(optional)(optional)

(optional)

(optional)(optional)

section

section

FS1(optional)

C19

OAT

ACT6 (optional)RAE (optional)

SD2(optional)

PC7

C11, 12 (optional)

SC11, 12(optional)Compressor

VFDOOESV11

SV9, SV10

CompressorControl Box

OOESV11

Econom izer

Filter

DX

Heatsect ion

Supply fan d ischargep lenumsect ion

Condenser

C19, 20

RAT

LT11 (op t ional)

S11, REC11SD2

RAE

ACT3

PC5

OAEVM 1

LT10 (op t ional)DAT

OAT

SC11, 21 (op t ional )

C11, 21 (op t ional)

(op t ional)

HTR3-4 (op t ional)

sect ion

sect ion

sect ion

return air

(op t ional)

(op t ional)

(op t ional)

(optional)

C9

FS1(op t ional)

HTR1-2, U1/ U2

S10, REC10 (op t ional)SD1 (op t ional)

ACT6

CompressorVFD

OOESV11

SV9, SV10

Page 14: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 14

Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT10, 11 Actuator Motors, Exhaust Dampers Return Air Section ACT12, 13 Actuator Motors, Enthalpy Wheel Bypass Damper Energy Recovery Section AS Airflow Switch, Burner Blower Gas Heat Box BM Burner Blower Motor Furnace Section C1- C4 Power Factor Capacitors, Compressors Condenser Section C10 Power Factor Capacitor, Supply Fan Supply Air Section C11 Capacitor, SpeedTrol Circuit #1 Cond. Bulkhead C20 Power Factor Capacitor, Return Fan Return Air Section C21 Capacitor, SpeedTrol Circuit #2 Cond. Bulkhead CB10 Circuit Breaker, Supply Fan Main Control Box CB20 Circuit Breaker, Return/Exhaust Fan Main Control Box CB60 Circuit Breaker, Energy Recovery Wheel Main Control Box CDS2 Discharge Thermostat VFD Compressor COMPR.1- 4 Compressors Condenser Section CS1, 2 Control Switches, Refrigeration Circuits Main Control Box DAT Discharge Air Temperature Sensor Discharge section DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS1 Disconnect, Total Unit or Condenser/Heat Main Control Box DS2 Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS6 Disconnect, Factory Powered Outlet Condenser Section EAT Exhaust Air Temperature Sensor Energy Recovery Section EFT Entering Fan Air Temperature Sensor Supply Fan Section ERM1, 2 Energy Recovery Wheel Motors Energy Recovery Section EXPA- D MicroTech III Expansion Boards Main Control Box F1A, B Fuses, Control Circuit Transformer, (T1) Primary Main Control Box F1C Fuse, Control Circuit Transformer, (T1) Secondary Main Control Box F2 Fuse, Control Circuit Transformer, (T2) Primary Main Control Box F3 Fuse, Burner Blower Motor Main Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section FB2M Fuseblock, Inverter Compressor Main Control Box FB10 Fuseblock, Supply Air Fan Main Control Box FB11, 12, 21, 22 Fuseblocks, SpeedTrol Main Control Box FB20 Fuseblock, Return Air Fan Main Control Box FB31- 40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Box FB41- 50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Box FB60 Fuseblock, Energy Recovery Wheel Main Control Box FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FP1, 2 Frost Protection, Refrigeration Circuits Coil Section, Cool FS1, 2 Freezestat Control Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Box GFR1, 2 Ground Fault Relays Main Control Box GFS1, 2 Ground Fault Sensors Main Control Box GFR4 Ground Fault Relay, Condenser Condenser Control Box

Electrical Legend

Page 15: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 15

Electrical LegendContinued

GFS4 Ground Fault Sensor, Condenser Condenser Control Box GRD Ground All Control Boxes GV1 Gas Valve, Pilot Furnace Section GV2 Gas Valve, Main/Safety Furnace Section GV3 Gas Valve, Redundant/Safety Furnace Section GV4- 8 Gas Valve, Main, Hi-Turn Down Furnace Section HL1- 10 High Limits, Power, Electric Heaters (Top Bank) Electric Heat Section HL11- 20 High Limits, Power, Electric Heaters (Bottom Bank) Electric Heat Section HL22 High Limit, Gas Heat (Prefilters) Supply Air Section HL23 High Limit, Gas Heat (Final Filters) Final Filter Section HL31- 40 High Limits, Control, Electric Heaters (Top Bank) Electric Heat Section HL41- 50 High Limits, Control, Electric Heaters (Bottom Bank) Electric Heat Section HP1- 4 High Pressure Controls, Refrigerant Cmpr./Press./Cond. Box HP5 High Pressure Control, Gas Furnace Section HS1 Heat Switch, Electric Shutdown Main Control Box HS3 Heat Switch, Electric Heat Deadfront Interlock Electric Heat Box HTR1- 4 Crankcase Heaters On Compressors HUM1 Humidistat Sensor Energy Recovery Section IT Ignition Transformer Furnace Section LAT Temperature Sensor, Leaving Air Energy Recovery Section LP1- 4 Low Pressure Controls, Refrigerant On Cmpr./Cond. Box LP5 Low Pressure Control, Gas Furnace Section LR10 Line Reactor, Supply Fan Inverter Bypass Box LR20 Line Reactor, Return/Exhaust Fan Inverter Bypass Box LR11, 21 Line Reactors, Condenser Fan SpeedTrol Pressure Control Box LS1, 2 Limit Switches, Low/High Fire Furnace Section LT10 Light, Supply Fan Supply Air Section LT11 Light, Return Fan Return Air Section LT12 Light, Heat Section Heat Section LT13 Light, Filter Section Filter Section LT14 Light, Final Filter Section Final Filter Section LT15 Light, Discharge Section Discharge Section LT16 Light, Blow-through Coil Section BlowThru Coil Section LT17 Light, Evaporator Coil Section Evaporator Coil Section LT18 Light, Preheat Section Preheat Section LT19 Light, Blank Section Blank Section LT20 Light, Blank/Empty Section Blank/Empty Section LT21 Light, Draw Thru Coil Section DrawThru Coil Section LT22 Light, Condenser Section Condenser Section M1, 3, 5 Contactors, Compressors Main Control Box M10 Contactor, Supply Fan Main Control Box M11- 18 Contactors, Condenser Fans, Circuit #1 Main Control Box M20 Contactor, Return Fan Main Control Box M21- 28 Contactors, Condenser Fans, Circuit #2 Main Control Box M29 Contactor, Burner Motor Furnace Section M30 Contactor Reversing, Inverter Bypass, Supply Fan Inverter Bypass Box M31- 39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Reversing, Inverter Bypass, Return Fan Inverter Bypass Box M41- 50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M60, 61 Contactors, Energy Recovery Wheel Motor Main Control Box MCB Microtech III Control Board Main Control Box

Schematic Sym. Description Location

Page 16: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 16

Electrical LegendContinued

MJ Mechanical Jumpers All Control Boxes MMP1, 3, 5 Manual Motor Protectors, Compressors Main Control Box MMP10 Manual Motor Protector, Supply Fan Main Control Box MMP11- 18 Manual Motor Protectors, Condenser Fans Ckt. 1 Main Control Box MMP20 Manual Motor Protector, Return fan Main Control Box MMP21- 28 Manual Motor Protectors, Condenser Fans Ckt. 2 Main Control Box MMP30 Manual Motor Protector, Inverter Bypass Supply Fan Inverter Bypass Box MMP40 Manual Motor Protector, Inverter Bypass Return Fan Inverter Bypass Box MMP51- 53 Manual Motor Protectors, Exhaust Fan(s) Prop Exhaust Box MMP60, 61 Manual Motor Protector, Energy Recovery Wheel Main Control Box MP1- 4 Motor Protectors, Compressors On Compressors OAE Enthalpy Control, Outside Air Economizer Section OAT Temperature Sensor, Outside Air Economizer Section OL61 Overload- Energy Recovery Wheel (575V) Main Control Box PB1, 2 Powerblock, Power Distribution Main Control Box PB3 Powerblock, Power Distribution, Electric Heat Electric Heat Section PB4 Powerblock, Power Distribution, Condenser Cond. Control Box PB9, 10 Powerblocks, Supply Fan Junction Box, Split Unit PB11, 12 Powerblocks, Power Distribution Main Control Box PB19, 20 Powerblocks, Return/Exhaust Fan Junction Box, Split Unit PC5 Pressure Control, Clogged Filter Pre Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Section PT11, 21 Pressure Transducers, SpeedTrol Pressure/Cond. Box PVM1, 2 Phase Voltage Monitors Main Control Box R11 Relay, Cond. Fan 11 SpeedTrol Inverter Enable Pressure/Cond. Box R17 Relay, Cond. Fan 21 SpeedTrol Inverter Enable Pressure/Cond. Ctrl. Box R20 Relay, Gas/Steam/Hot Water Furn./Main Ctrl. Box R21, 22 Relays, Gas Heat, 20:1 High Turndown Furn./Main Ctrl. Box R23 Relay, Gas Heat Furnace Section R24 Relay, Gas Heat Alarm Main Control Box R25 Relay, Gas Heat, Start Supply Fan Inverter Main Control Box R26 Relay, Isolation/Exhaust Dampers Main Control Box R28 Relay, Isolation Damper Safety Main Control Box R38- 40 Relays, Compressor Inverter Heater & Fans Compressor Control Box R45 Relay, UV Lights Main Control Box RAE Enthalpy Sensor, Return Air Return Air Section RAT Temperature Sensor, Return Air Return Air Section REC1 Receptacle, Main Box Main Control Box REC2 Receptacle, Condenser Box Cond. Control Box REC3 Receptacle, Field Power, 115VAC Discharge Bulkhead REC10- 23 Receptacles, Cabinet Sections Cabinet Sections RHB1, 2 Interface Board, Modulating Hot Gas Reheat Main Control Box S1 Switch, System On/Off Main Control Box S3 Switch, Furnace On/Off Furnace Section S4 Switch, Inverter Bypass On/Off Main Control Box S40- 45 Switches, Door Interlock, UV Lights Cabinet Sections SC11 Speed Control, Circuit #1 Cond. Bulkhead SC21 Speed Control, Circuit #2 Cond. Bulkhead SD1 Smoke Detector, Supply Air Discharge Section

Schematic Sym. Description Location

Page 17: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 17

Electrical LegendContinued

Schematic Sym. Description Location SD2 Smoke Detector, Return Air Return Air Section SHS1 Sensor, Space Humidity Return Section (Field inst.) SPS1, 2 Sensors, Static Pressure, Duct or Building Main Control Box SV1, 2 Solenoid Valves, Liquid/Drop Condenser Section T1 Transformer, Main Control, Line/115VAC Main Control Box T2 Transformer, Control Input, 115/24VAC Main Control Box T3 Transformer, Control Output, 115/24VAC Main Control Box T6 Transformer, Factory Powered outlet, Line/115VAC Condenser Section T7 Transformer, Hot Gas Reheat, 115/24VAC Main Control Box T11 Transformer, SpeedTrol, Line/240VAC Condenser Section TB1 Terminal Block, Internal for Transformers Main Control Box TB2 Terminal Block, Field Main Control Box TB3 Terminal Block, Factory, 115/24VAC Main Control Box TB4 Terminal Block, Field, 115VAC Main Control Box TB7 Terminal Block, 115VAC Convenience Outlet Main Control Box TB11 Terminal Block, Heating Furn./Elect. Heat Ctrl. Box TB14 Terminal Block, Inverter Compressor Control Box Compressor Control Box TB25- 28 Terminal Blocks, Split Unit Junction Box Split Unit Junction Box TB35- 37 Terminal Blocks, Pressure Controls Pressure Control Box TD20 Time Delay, Return Air Fan Main Control Box TR1, 2 Transducer, Pressure, SpeedTrol Main Control Box VFD/AFD2 Adjustable Frequency Drive, Inverter Compressor Compressor Control Box VFD/AFD10 Adjustable Frequency Drive, Supply Fan Draw thru/Supply Section VFD/AFD11, 21 Adjustable Frequency Drive, Cond. Fan SpeedTrol Pressure/Cond. Ctrl. Box VFD/AFD20 Adjustable Frequency Drive, Return/Exhaust Fan Dr. Thru/Ret./Exh. Section VFD/AFD60 Adjustable Frequency Drive, Energy Recovery Wheel Energy Recovery Section UV Ultra-Violet Light(s) Coil/Discharge Section VM1 Valve Motor #1, Heating Furnace/Heating Section VM5 Valve Motor #5, Cooling Coil Section, Cooling VV1 Vent Valve, Gas Heat Furnace Section ZNT1 Sensor, Zone Temperature Field Installed

Page 18: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 18

Section A1- Outdoor/Return Air SectionNotes

Primary Codes that pertain: 19, 20, 21, 22, 58Additional Codes that pertain: 06, 09, 14, 15, 16, 17, 23, 24, 33, 48, 49

Codes 19 and 20 determine the base section. Code 19 is the Return Air Plenum and determines if the unit has Back/Horizontal Return Air, Bottom Return Air, Left, or Right Side discharge. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 20= BE, DE, EE, FE, GE). The only case in which a Plenum is not required is when a 100% Outdoor Air Damper and Hood are ordered (Code 20= AE). For units with Heat/Energy Recovery (Code 20= 3E, 4E, 5E, 6E) see Section A2.

Code 21 determines the Return Fan size and type. Code 22 determines the Return Fan Motor horsepower and type. Code 58 determines the drive selection. These codes only pertain to units with a 0-100% Economizer (Code 20= DE, EE, FE, GE). The Return Air Fan section parts, the fans, and the motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Return Fan motors range from 2- 30 horsepower, and the Fan is a 40” single width Airfoil Wheel.

Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Code 09, unit voltage, is part of the Return Fan Motor part number identification.

Codes 14 & 15 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 14= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 14= 2, 4 there is a separate Inverter Section. If Code 14= Y, there are no Inverters. Code 15 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its’ own Control Box. Codes 14 and 15 DO NOT apply to this inverter.) For Return Air Section inverter part numbers, refer to Section F the Supply Air Section.

Code 16 determines if the unit has a Smoke Detector located in the Return Air cabinet. If Code 16= 1, 3 a Smoke Detector (SD2) is present in the Return Air Section.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 17 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection.

Code 23 indicates the presence of Plenum/Vestibule Lights, UV lights, 115V Service Outlet, and/or Intelligent Equipment.

Code 24 indicates the presence of Exhaust Fans.

Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for Gauge part number and description. Code 33 also indicates if the unit is California Title 24 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Code 48 determines if the unit is equipped with IBC seismic construction.

Code 49 determines if the Return Air Cabinet has a Light, Switch and Receptacle (Code 49= B, E), Fan Belt Guards (Code 49= D) OR both (Code 49= F).

Page 19: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 19

Ref. Part Part Qty. No. Description Number 4 Damper Assy- Complete 1 1 Damper only 098313701 2 1 9 Liner 056132601 2 10 Panel- Hood Side 056131903 1 11 Panel- Hood Side 056131904 1 12 Panel- Hood Top 056131802 1 13 Louver 056132002 3 14 Channel- Support 056132303 2 15 Channel- Support 056132102 2

Section A1- Outdoor/Return Air Section100% Outside Air Damper with Hood

Code 20= AE AND Code 19= YYNo Return Air Plenum

1 This Damper Assy. includes the Damper, Damper Linkage, and Actuator. For Damper Assy. components see the following page. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified.

2 Damper only, NO Actuator Linkage OR Actuator.

11

AirFlow

9

15

15

14

12 4

13

9

10

Section B

Page 20: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 20

Section A1- Outdoor/Return Air Section100% Outside Air Damper w/ACT3

Code 20= AE AND Code 19= YY

25

27

23

29

26

16

28 24

23

214 214

6

19

22

Motorized Linkage Detail:

14

13

17

20

39

1922

Ref. Part Part Qty. No. Description Number 4 Shaft- Linkage 055979701 2 6 Adapter Plate- Crank Arm 403642801 1 13 Blade- Damper 044195102 12 14 Grille 055616801 2 16 Stop-Anti Rotate, Damper 065779801 2 17 Support- Damper Motor 403642001 1 19 Linkage Bar Drive Tab 044194900 2 20 Crank Arm- Damper 403641901 1 21 Ball Joint- Damper 000887000 4 22 Actuator- Motorized, 24V ACT3 113139501 1 23 Bushing- Linkage Bar, Nylon 046098300 12 24 Bushing- Damper Blade, Nylon 043730400 24 25 Gasket- Vinyl 044193115 12 26 Gasket- Vinyl 045655715 1 27 Plug- Damper End 041003501 12 28 Plug- Damper End 041003502 6 29 Plug- Damper End 041003503 6 39 Bearing- Flange Sleeve 047138504 2

Page 21: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 21

Section A1- Outdoor/Return Air Section0 - 30% Outside Air Section w/ ACT3: Code 20= BE

30

9

3331

32

26

12

8

10

1411

Linkage Detail

34

35

15

36

48

13

47

15

3634

Ref. Part Part Qty. No. Description Number Damper Assembly- Complete 1 1 Damper only 098313901 2 1 8 Blade- Damper 044193212 3 9 Gasket- Vinyl 055940203 1 10 Gasket- Vinyl 044193124 3 11 Seal- End 055941901 2 12 Grille 055593601 1 13 Support- Motor 403672202 1 14 Bar- Linkage 055593701 2 15 Shaft- Linkage 055536608 1 26 Louver 055593202 4 30 Plug- End 041003505 3 31 Plug- End 041003506 3 32 Bushing- Damper Blade 043730400 6 33 Bushing- Linkage Bar, Nylon 046098300 6 34 Ball Joint- Damper 000887000 2 35 Actuator- Motorized, 24V ACT3 113139501 1 36 Crank Arm- Damper 403666401 1 47 Bushing- Actuator 047138504 1 48 Channel Retainer 910106063 11 Damper assy includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin

Applied with model and serial number information so that the correct assembly can be identified.2 Damper only, NO Actuator Linkage OR Actuator.

Page 22: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 22

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Barometric Exhaust Damper

Units without Return Air FansCode 20= DE, EE, FE, GE AND Code 21= YYYY

Ref. Part Part Qty. No. Description Number 11 Economizer Damper w/ Actuator 1, 2 1

12 Exhaust Damper Assy. Powered (Code 20= EE, GE) 112040447 1 Barometric (Code 20= DE, FE) 112039647 11 Economizer detail two pages after next. 2 For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that

the correct assembly can be identified.

12

11

Back Return (Code 19= HY) shown.

Air Flow

Page 23: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 23

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Barometric Exhaust Damper

Units with 40” Return Air FansCode 20= DE, EE, FE, GE

Code 21= 40B1, 40B2, 40B3

Ref. Part Part Qty. No. Description Number 11 Economizer Damper w/Actuator Code 20= DE, EE, FE, GE 1, 2 1

160 Exhaust Damper Assy. Powered Code 20= EE, GE 055552820 1 Barometric Code 20= DE, FE 055552810 1

50 Belt Guard Code 49= D, F 055962201 1 51 Belt Guard Code 49= D, F 055962202 1 55 Gasket 055921413 2 56 Gasket 055921414 21 Economizer detail on page after next.2 For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that

the correct assembly can be identified.

11

Bottom Return (Code 19= BY) shown

5150

55 56

55 56

(See Return Fan Detail)

(See Return Fan Detail)

Air Flow

160

Page 24: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 24

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Prop Exhaust Fan & Damper

Code 20= HE, JE AND Code 24= 1, 2

20

420

41

15

Section Assembly Detail2 fan arrangement shown

(Code 24= 2)

Fan Guard

Ref. Part Part Qty. No. Description Number 420 Fan Assembly 1 208/230/460V 111056601 2

Fan Assembly 1 575V 111056602 2

15 Fan Guard 111181901 1 3

20 Panel- Weather Hood 111173101 1 3

41 Hood- Prop Exhaust 111182301 1 3

N/S Grille Only- Prop Exhaust Hood 111182101 1 3

N/S= Not Shown on diagram.1 See detail following Isolation Damper Detail. 2 Quantity may be one (Code 24= 1) OR two (Code 24= 2).3 Quantity is PER fan.

420

Page 25: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 25

Section A1- Outdoor/Return Air Section0 - 100% Economizer Damper w/ ACT3

Code 20= DE, EE, FE, GE, HE, JEDiagrams

LinkageDetail

16 24

13

27

25

28

29

19

23

22

4 21

721

6

26

18

24

11

31

123

19

1922

Page 26: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 26

Section A1- Outdoor/Return Air Section0 - 100% Economizer Damper w/ ACT3

Code 20= DE, EE, FE, GE, HE, JEComponents

Ref. Part Part Qty. No. Description Number Damper Assy- Complete 1 1 Damper Assembly 098313201 2 1 4 Shaft Assembly 058390001 1 6 Plate- Crank Arm 066302059 1 7 Shaft- Linkage 058389901 1 11 Channel- Support 403630501 1 13 Blade- Damper 044195102 12 16 Stop/Anti-Rotate- Damper 065779801 4 18 Bar- Linkage 044194800 2 19 Drive Tab- Linkage Bar 044194900 2 21 Ball Joint- Damper 000887000 4 22 Actuator- 24V ACT3 113139501 1 23 Bushing- Linkage Bar 046098300 12 24 Bushing- Damper Blade 043730400 24 25 Gasket- Vinyl 044193115 12 26 Gasket- Vinyl 045655715 2 27 End Plug- Damper 041003501 12 28 End Plug- Damper 041003502 6 29 End Plug- Damper 041003503 6 31 Bushing- Actuator 047138504 1 123 Channel- Actuator 403659701 1 N/S Gasket- Neoprene 3 056003501 4N/S= Not Shown on Diagram.1 Damper Assy. includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin

Applied with model and serial number information so that the correct assembly can be identified.2 Damper Assy. includes the Damper and Damper Linkage, but NO Actuator.3 Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel.

Page 27: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 27

Section A1- Outdoor/Return Air SectionCalifornia Title 24 Assembly

Code 33= *F***

Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch 404159561 1 3534 Bracket, Mounting Switch 404159562 1 3535 Switch, Push Button SPDT 033696300 2 3536 Bushing, Conduit 113116301 1

3533

3536

3534

3535

Page 28: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 28

Section A1- Outdoor/Return Air SectionReturn Air Plenum Isolation Damper w/ Actuator ACT6

Code 19= BE

15

23

3

16

424

20

211822

22

17

19

15

20

ACT6 Actuator Detail

Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized 403718123 1 3 Motor Mount Assembly 055921201 1 4 Blade Assembly- Return, 4” 055921301 9 15 Angle- Linkage 055916702 1 16 Angle- Blade 055638102 1 17 Shaft- Damper Blade 055637801 12 18 Shaft- Linkage 055536601 1 19 Bearing- Flange, Nylon 001113500 12 20 Actuator- Motorized, 24V ACT6 113144901 1 21 Crank Arm- Damper 403717101 1 22 Ball Joint 000887000 2 23 Bearing- Sleeve 047138507 18 24 Gasket- Vinyl 030051979 7 25 Bracket- Support 403716801 1 26 Retainer- Actuator 403717301 1 27 Bearing- Sleeve 047138504 1

21

26

27

25

Page 29: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 29

Section A1- Outdoor/Return Air SectionProp Exhaust Fan & Damper

Code 20= HE, JE AND Code 24= 1, 2

6B

6E

6G6H

6I

Fan Assembly Components2 Fan Arrangement Shown

(Code 24= 2)420420A

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 AFD20 Inverter see charts on following page 1A Resistor- Inverter 044690105 1 1 1 1 1B Jumper- Inverter 1 055719731 3 3 3 3 6B Fan Prop- 36” 300044027 14 14 14 14

6C Fan Shaft 300044028 14 14 14 14

6D Bearing 300044029 24 24 24 24

6E Fan Sheave 019291400 14 14 14 14

6F Bushing- Fan Sheave 000804000 14 14 14 14

6G Belt 049260805 24 24 24 24

6H Motor Sheave 000607600 14 14 14 14

6I Motor 300046887 14 14 14

Motor 300046251 14

51 Tube- Plastic 2 020954800 8’ 8’ 8’ 8’ 53 Coupling- Tube 2 .25 x .125 FPT 021213800 2 2 2 2 54 Fitting- Grease 2 000109800 2 2 2 2 420 Fan Assembly- Complete 111056601 4 4 4

Fan Assembly- Complete 111056602 4

420A Damper- Backdraft 3 4 4 4 4

208V

230V

460V

575V

54

53

51

Lube Line Detail

11A

1B

Control Box(see following page

6C 6D

6F

1 Quantity= 2 when Inverter model 3500 (Code 15= G) is used.2 Quantity shown is for 1 fan (Code 24=1). Quantities for 2 fan units (Code 24= 2): Ref. 51= 25’; Ref. 53= 4; Ref. 54= 4.3 Contact Daikin Applied.4 Quantity is PER fan.

Page 30: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 30

Section A1- Outdoor/Return Air SectionProp Exhaust Fan & Damper

Code 20= HE, JE AND Code 24= 1, 2Continued

Voltage Code Inverter Model Part 15= Number A 550 112046015 1 1 550 112046002 1 B MD4 193552215 1 1 MD4 193552202 1 G 3500 205858812 1 1 3500 205858822 1 3500 205858843 1 Q MD2 193552215 1 1 MD2 193552202 1 R VTAC9 111046868 1 1 VTAC9 111046854 1 S MD2 193475809 1 1 MD2 193475825 1

208V

230V

460V

575V

Inverter- 1 Fan Units (Code 24= 1) Voltage Code Inverter Model Part 15= Number A 550 112046017 1 1 550 112046004 1 B MD4 193552217 1 1 MD4 193552204 1 G 3500 205858814 1 3500 098656928 1 3500 205858824 1 Q MD2 193552215 1 1 MD2 193552202 1 R VTAC9 111046870 1 1 VTAC9 111046856 1 S MD2 193475811 1 1 MD2 193475827 1

208V

230V

460V

575V

Inverter- 2 Fan Units (Code 24= 2)

220

230

2 Fan Unit shown

Voltage Ref. Sch. Part Part No. Sym. Description Number 220 OL51, 52 Overload 193548010 2 Overload 193548009 2 Overload 193547910 2 Overload 193547909 2 230 M51, 52 Contactor 25A 193537304 2 Contactor 16A 193592006 2 Contactor 9A 193534106 2 Contactor 7A 193534105 2

208V

230V

460V

575V

OL51 OL52

M51 M52

220

230

Prop Exhaust Fan Control Box

Page 31: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 31

Section A1- Outdoor/Return Air SectionDesign Flow Detail

Code 20= FE, GE, JE

Ref. Part Part Qty.1

No. Description Number 1 Louver Panel Left Hand Door 059595204 10 Louver Panel Right Hand Door 059595203 10 2 Grille 055541401 1 3 Gasket 055921402 2 4 Gasket 055921401 1 9 Potentiometer 098663701 1 12 O-Ring- Potentiometer 098663801 1 104 Panel- Vane 098661802 1 105 Shaft- Upper 098662601 1 106 Bearing- Lower 091634501 1 109 Crank Arm Assy Left Hand Door 091658802 1 Crank Arm Assy Right Hand Door 091658801 1 110 Link Arm 2 1 120 Bearing 060014201 1 127 Bearing 047138535 1 130 Spring- Main .75” x 2” 098664801 1 131 Spring- Secondary .30” x 1.5” 098664901 1 N/S Leveling Kit- Design Flow 091659301 1

2

9 127

12

110120 109 104

105

106

131

130104

1

Section Final Assembly

Design Flow Vane and Vane Bearings Detail

Adjuster Control AssyDetail

SpringDetail

LH Louvered Door Assy

RH Louvered Door Assy

Louvered DoorAssembly Detail

3➤

4

1 Quantity is PER door.2 P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be

identified.

Page 32: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 32

Section A1- Outdoor/Return Air Section40” Return Air Fan (Code 21= 40B*) 1

Ref. Part Part Qty. No. Description Number 1 Motor see tables one & two pages after next Fan Housing Assy- Inlet Funnel 031940905 1 2 Inlet Funnel 031940905 1 6 Wheel- Air Foil Fan, SI/SW 40” 066543242 1 7 Mount- Motor 055552401 1 13 Shaft 1.937” Diameter 055541902 1 15 Coupling 1/8” MPT 027674000 2 16 Coupling- Reducer 1/4” X 1/8” FPT 021213800 2 17 Tubing- Plastic 021136745 2 19 Grease Fitting 1/8” MPS 000109800 2 20 Bearing- Ball 1.937” bore 020648603 2 26 Key- Wheel 1/2” X 5 1/2” 023221513 1 27 Key- Fan Sheave 1/2” X 4 1/2” 023221507 1

1

7

272613

6

15 1716 20

1520 161719

1 Mounting type, fourth digit: 1= RIS, 2= Spring, 3= Spring w/ Seismic Snubbers.

2

Page 33: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 33

Section A1- Outdoor/Return Air SectionReturn Air Fan Mounts (Code 21= 40B*)

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 21= 40*2 251783201 4 Seismic Code 21= 40*3 251783301 4 161 2 Spring Mount- Yellow 251784501 1 3, 5 Spring Mount- Yellow 251784601 1 7.5- 15 Spring Mount- Green 251784701 1 20- 30 Spring Mount- Dark Brown 251784801 1 162 2, 15, 20, 25 Spring Mount- Dark Brown 251784801 1 3- 10 Spring Mount- Green 251784701 1 30 Spring Mount- Red 251784901 1 163 2- 5 Spring Mount- Yellow 251784501 1 7.5- 30 Spring Mount- Blue 251784401 1 164 2 Spring Mount- Dark Brown 251784801 1 3- 7.5 Spring Mount- Yellow 251784601 1 10- 20 Spring Mount- Yellow 251784501 1 25, 30 Spring Mount- Blue 251784401 1 181 All Nut Spring Code 21= 40*2 059992201 12 Seismic Code 21= 40*3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 21= 40*2 112047201 12 Seismic Code 21= 40*3 112047201 20

Spring Mounts (Code 21= 40B2) & Seismic Spring (40B3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 055512101 4 61 2 - 20 Rubber Mount- Black 021639704 1 25, 30 Rubber Mount- Red 021639701 1 62 2 - 10 Rubber Mount- Black 021639704 1 15 - 30 Rubber Mount- Red 021639701 1 63 2 - 30 Rubber Mount- Black 021639704 1 64 2 - 30 Rubber Mount- Black 021639704 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 040500310 8

Rubber Mounts (Code 21= 40B1)

Rubber Mounts

64

61

62

Mounting Diagram

Spring Mounts

161 or

163 or 63

164 or

162or

92

93

89

81 91

21

61 62

63 64

91

161 162

163 164

188

189

181

121

Seismic strap used only when Code 21= 40B3.

Page 34: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 34

H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Motor Code 22= Voltage C22= *EY C22= *JY C22= *HY C22= *KY Mount 1

C09= 12 2 G*Y 208/60/3 039895700 046515500 049100300 073321000 073316604 3 H*Y 208/60/3 039447500 065817100 047358100 065819400 073316605 5 J*Y 208/60/3 039447600 065817200 049186800 065819500 073316606 7.5 K*Y 208/60/3 037530300 065817300 047665900 065819600 073316607 10 L*Y 208/60/3 038999000 065817400 047666100 065819700 073316608 15 M*Y 208/60/3 039896200 065817500 049186900 065819800 073316609 20 N*Y 208/60/3 039895800 065817600 049187000 065819900 073316610 25 P*Y 208/60/3 039448900 065817700 049187100 065820000 073316611 30 Q*Y 208/60/3 041775200 205066500 049187200 205066800 073316612 C09= 29 2 G*Y 230/60/3 039446300 205163500 047446000 073321000 073316604 3 H*Y 230/60/3 039442400 065818100 049262300 065820100 073316605 5 J*Y 230/60/3 039442500 065818200 040161200 065820200 073316606 7.5 K*Y 230/60/3 039448700 065818300 049100500 065820300 073316607 10 L*Y 230/60/3 039446500 065818400 044691100 065820400 073316608 15 M*Y 230/60/3 039446600 065818500 038689700 065820500 073316609 20 N*Y 230/60/3 039448800 065818600 040161300 065820600 073316610 25 P*Y 230/60/3 039896100 065818700 040161400 065820700 073316611 30 Q*Y 230/60/3 040626800 205066600 049025300 205066900 073316612 C09= 27 2 G*Y 460/60/3 039446300 205163500 047446000 073321000 073316604 3 H*Y 460/60/3 039442400 065818100 049262300 065820100 073316605 5 J*Y 460/60/3 039442500 065818200 040161200 065820200 073316606 7.5 K*Y 460/60/3 039448700 065818300 049100500 065820300 073316607 10 L*Y 460/60/3 039446500 065818400 044691100 065820400 073316608 15 M*Y 460/60/3 039446600 065818500 038689700 065820500 073316609 20 N*Y 460/60/3 039448800 065818600 040161300 065820600 073316610 25 P*Y 460/60/3 039896100 065818700 040161400 065820700 073316611 30 Q*Y 460/60/3 040626800 205066600 049025300 205066900 073316611 C09= 37 2 G*Y 575/60/3 049181000 205168300 049188200 046514400 073316604 3 H*Y 575/60/3 046741600 046511700 049188300 046514500 073316605 5 J*Y 575/60/3 046741900 205168900 049188400 046514600 073316606 7.5 K*Y 575/60/3 047443300 205168800 049188500 046514700 073316607 10 L*Y 575/60/3 047443400 205168600 049188600 065821400 073316608 15 M*Y 575/60/3 047443500 205166600 049185200 065821500 073316609 20 N*Y 575/60/3 049181100 205166800 049188700 065821600 073316610 25 P*Y 575/60/3 049181200 205166900 049188800 065821700 073316611 30 Q*Y 575/60/3 049181300 205066700 049188900 205067000 0733166121 Note that the Return Fan Motor Mounts listed are used ONLY in Heat Recovery units when Code 21= 40B* AND Code 20=

3*, 4*, 5*, 6*. See the 40” Return Fan Detail in Section A2- Outdoor/Return Air w/ Heat Recovery Section.

Section A1- Outdoor/Return Air SectionReturn Air Fan Motors

Standard Motors: Code 22= **Y

Page 35: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 35

Section A1- Outdoor/Return Air SectionReturn Air Fan Motors

Shaft Grounded Motors: Code 22= **S 1

H.P. Motor HP Unit ODP PrEff. TEFC PrEff C22= **S Voltage C22= *JS C22= *KS C09= 12 2 G*S 208/60/3 046515599 N/A 3 H*S 208/60/3 300052109 065819499 5 J*S 208/60/3 300052118 065819599 7.5 K*S 208/60/3 065817399 065819699 10 L*S 208/60/3 065817499 065819799 15 M*S 208/60/3 065817599 065819899 20 N*S 208/60/3 065817699 065819999 25 P*S 208/60/3 065817799 065820099 30 Q*S 208/60/3 205066599 205066899 C09= 29 2 G*S 230/60/3 300049697 300049687 3 H*S 230/60/3 300049698 300049688 5 J*S 230/60/3 300049699 300049689 7.5 K*S 230/60/3 300049700 300049690 10 L*S 230/60/3 300049701 065820499 15 M*S 230/60/3 065818599 300049198 20 N*S 230/60/3 065818699 300049691 25 P*S 230/60/3 300049702 300049692 30 Q*S 230/60/3 300049703 205066999 C09= 27 2 G*S 460/60/3 300049697 300049687 3 H*S 460/60/3 300049698 300049688 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 10 L*S 460/60/3 300049701 065820499 15 M*S 460/60/3 065818599 300049198 20 N*S 460/60/3 065818699 300049691 25 P*S 460/60/3 300049702 300049692 30 Q*S 460/60/3 300049703 205066999 C09= 37 2 G*S 575/60/3 205168399 046514499 3 H*S 575/60/3 046511799 205168499 5 J*S 575/60/3 205168999 046514699 7.5 K*S 575/60/3 205168899 046514799 10 L*S 575/60/3 205168699 065821499 15 M*S 575/60/3 205166699 065821599 20 N*S 575/60/3 205166899 065821699 25 P*S 575/60/3 205166999 065821799 30 Q*S 575/60/3 098865399 205067099N/A= Not Available.1 For Return Fan Motor Mounts used in Heat Recovery units (when Code

21= 40B* AND Code 20= 3*, 4*, 5*, 6*) refer to the previous page.

Page 36: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 36

Section A1- Outdoor/Return Air SectionSection Mounted Controls

OAE, RAE, LT11, S11, REC11

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT11 065492402 1 88 Light Switch- S11 065492201 1 89 Receptacle- REC11 030187000 1

LT11- Return Fan Light/S11- Return Fan Light Switch/REC11- Return Fan ReceptacleCode 49= E, F

Return Air Opening

30

Return Air

Opening

30

Ref. Part Part Qty. No. Description Number 30 Smoke Detector- SD2 098873101 1

SD2- Return Air Smoke DetectorCode 16= 1, 3

Back ReturnCode 19= HY

Bottom ReturnCode 19= BY, BE

7

Ref. Part Part Qty. No. Description Number 7 Sensor- RAT 193414602 1

RAT- Outdoor Air Temperature Sensor

84 85

88 89

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 910146257 1 41 Control- OAE 113103601 1

40OAE- Mechanical Enthalpy (Code 17= Y*)

41

48

42

Economizer Damper

Bottom ReturnShown

Code 19= BY, BE

Bottom ReturnShown

Code 19= BY, BE

Economizer Damper

40

41

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 910146257 1 41 Control- OAE 113103601 1 42 Mount- RAE Enthalpy 055732301 1 48 Control- RAE 113103701 1

OAE & RAE Differential Enthalpy (Code 17= C*)

Page 37: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 37

Section A2- Outdoor/Return Air w/ Heat Recovery SectionNotes

Primary Codes that pertain: 19, 20, 21, 22, 24, 58Additional Codes that pertain: 06, 09, 14, 15, 16, 17, 23, 48, 49

Codes 19 and 20 determine the base section. Code 19 is the Return Air Plenum; Code 20 determines the type of Outdoor Air/Heat Recovery control used. When Code 20= 3E, 5E the unit has a 6” Heat Recovery Wheel. If Code 20= 4E, 6E the unit has a 12” Heat Recovery Wheel.

Codes 21, 22, and 58 determine the Return Air Fan, Fan Motor and drive selection. The fan section parts, the Fans, and the Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. The motors range from 2- 30 horsepower, and the Fan is a 40” Single width Airfoil Wheel.

Code 24 determines if the Heat Wheel has a Frost Protection Inverter (VFD/AFD60) mounted in the section.

Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Code 09, the voltage, is part of the Return Fan Motor part number identification.

Codes 14 & 15 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 14= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 14= 2, 4 there is a separate Inverter Section. If Code 14= Y, there are no inverters. Code 15 specifies the inverter vendor. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its’ own Control Box. Codes 14 and 15 DO NOT apply to this inverter.) For Return Air Section Inverter part numbers, refer to the Supply Air Section (Section F).

Code 16 determines if a Smoke Detector is located in the Return Air Cabinet. If Code 16= 1, 3, a Smoke Detector (SD2) is present.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 17= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 17 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection.

Code 23 (Mid 2012 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/HGRH inverter brand specified, and/or the presence of Intelligent Equipment.

Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for part number and description. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Code 48 determines if the unit is equipped with IBC seismic construction.

Code 49 determines if the Return Air Cabinet has a Belt Guard (Code 49= D), OR a Belt Guard and a Fan Section Light (Code 49= F).

Page 38: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 38

Cabinet Gaskets, Doors and Exhaust Hoods

(LH components shown)439

440

437437

Exhaust Hood- See Detail to Left

420

421 437 414

418

502

503

505

504

Section A2- Outdoor/Return Air w/ Heat Recovery SectionCabinet Gaskets, Doors, Hardware, Exhaust Hoods

Code 20= 3E, 4E, 5E, 6E

Ref. Part Part Qty. No. Description Number 414 Hinge 032457700 2 415 Door 24” 111208802 4 418 Door- Exhaust 48” 111209601 1 419 Door- Exhaust 48” 111209602 1 420 Door 24” 111208801 4 421 Door 48” 111209202 1 423 Door 48” 111209201 1 437 Gasket- Vinyl 055921411 24 439 Gasket- Vinyl 055921409 12 440 Gasket- Vinyl 055921408 24 502 Damper- Back Draft 39.38 x 31.25 111209301 2 503 Panel- Hood 111209802 2 504 Panel- Hood RH 111074702 2 505 Panel- Hood LH 111074602 2

437418

437

414

423

415Hoo

d419

Page 39: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 39

Section A2- Outdoor/Return Air w/ Heat Recovery SectionBase Components, Hood, Dampers

Code 20= 3E, 4E, 5E, 6E

144

142

145 146 141

148140

See Hood Detail to Left

Outdoor Air Intake Hood Detail

230

160

230

2011

31

30

202

211

205

211

204

12A210215

210215

12

Base Assembly

Ref. Part Part Qty. No. Description Number 1 Fan Assembly 1

12 Damper- OA Low Leak w/ Actuator ACT3 2 1 12A Damper- RA Low Leak w/ Actuator ACT4 2 1 30 Channel- Fan 251849801 1 31 Channel- Fan 251849901 1 140 Panel- Outdoor Intake Hood, Top 251840701 1 141 Panel- Outdoor Intake Hood, Side 251841101 1 142 Panel- Outdoor Intake Hood, Side 251841201 1 144 Louver- Outdoor Intake Hood 251840801 1 145 Louver- Outdoor Intake Hood 251840901 1 146 Louver- Outdoor Intake Hood 251841001 1 148 Screen- Outdoor Intake Hood 251841801 2 160 Wheel, Enthalpy- Heat Recovery 3

201 Filter Rack- Upper LH 251846701 1 202 Filter Rack- Upper RH 251846702 1 204 Filter Rack- Lower LH 251846602 1 205 Filter Rack- Lower RH 251846601 1 210 Filter- 30% 16 x 20 x 2 031298001 14 211 Filter- 30% 16 x 25 x 2 031298002 42 215 Stop- Filter 011484101 14 230 Damper- “L” Bypass w/ Actuator ACT12, 13 4 21 See detail on following page.2 See detail following Fan Mount detail.3 See detail following “L” Bypass Damper detail.4 See detail following Low Leak Damper detail.

Page 40: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 40

Section A2- Outdoor/Return Air w/ Heat Recovery Section40” Return Air Fan (Code 21= 40B*)

432411

072

452

490

434

Ref. Part Part Qty. No. Description Number 072 Inlet Funnel 251851101 1 411 Bearing, Roller- Drive Side 2 3/16” 300042661 1 412 Bearing- Inlet Side 2 3/16” 020648654 1 432 Shaft, 2 3/16” 113174340 1 434 Key 023221518 1 452 Fan Wheel 206007740 1 490 Motor Mount 1 11 See Return Air Fan Motor Section.

Motor 1

412

Page 41: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 41

Section A2- Outdoor/Return Air w/ Heat Recovery Section40” Return Air Fan Fan Mounts (Code 21= 40B*)

Ref. Fan Motor Part Part Qty. No. HP Description Number 34 2- 5 Spring Mount- Green 251784701 1 7.5- 30 Spring Mount- Dark Brown 251784801 1 35 2- 10 Spring Mount- Dark Brown 251784801 1 15, 20 Spring Mount- Red 251784901 1 30 Spring Mount- Tan 251785001 1 36 2- 7.5 Spring Mount- Dark Brown 251784801 1 10- 30 Spring Mount- Red 251784901 1 37 2- 30 Spring Mount- Dark Brown 251784801 1 38 All Mount Spring Code 21= 40B2 251783201 4 Seismic Code 21= 40B3 251783301 4 40 All Nut, Clinch 059992201 24 41 All Screw, 3/8-16 x 1.5” 112047201 8

Spring Mounts (Code 21= 40B2) & Seismic Spring (40B3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 34- 36 All Rubber Mount- Red 021639701 4 38 All Channel- Mount Support 404079350 4 40 All Nut, Clinch 059992201 24 41 All Screw, 3/8-16 x 1.5” 112047201 8 42 All Screw, 5/16-18 040501412 8 44 All Nut- 1/2-13 032333305 8 49 All Washer- Plain, 1/2” 040500310 4 50 All Screw, Cap 040499501 12

Rubber Mounts (Code 21= 40B1)

Rubber Mounts

34

Mounting Diagram

Spring Mounts

3635

37

44

42

40

41

49

38

34 35

36 37

50

41

40

38

Seismic strap used only when Code 21= 40B3.

34 35

36 37

Page 42: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 42

Section A2- Outdoor/Return Air w/ Heat Recovery SectionLow Leak Damper Detail (Ref. #12, 12A)

with ACT3 (Outside Air) OR ACT4 (Return Air)MicroTech III Controls (Code 12= *E, *F, *W)

122

119

127

116

114

126

127

125

128

129

120

116

128

ACT3 OR ACT4

Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator 111206409 Complete Assy- Less Actuator 251868501 114 Seal- End 043734314 2 116 Stop- Damper 047110101 2 119 End Plug 057783404 1 120 Blade- Damper 047793308 4 122 Actuator, 24V ACT3, 4 113139501 1 125 End Plug 041003508 4 126 End Plug 041003509 3 127 Bushing- Linkage 046098300 6 128 Bushing- Damper Blade 043730400 5 129 Shaft- Drive 043734000 2 N/S Gasket- Vinyl 044193135 4 N/S Gasket- Vinyl 055940221 1N/S= Not Shown on diagram.NOTE- The drawing is a generic illustration of this damper type, and shows part

location, but does not show the actual part quantities listed in the table.

Page 43: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 43

22

23

Ref. Part Part Qty. No. Description Number Complete Assembly w/ Actuator 251849329 Complete Assembly w/o Actuator 251847129 12 Blade- Damper 251853801 5 13 Blade- Damper 251848801 1 16 Linkage- Channel 251848901 1 17 Gasket- Vinyl 055940222 1 18 Gasket- Vinyl 044193136 5 19 Gasket- Vinyl 044193137 1 20 Plug, End- Damper 041003503 6 21 Plug, End- Damper 041003501 5 22 Stop- Damper 047110101 1 23 Bushing- Damper Blade 043730400 11 24 Bushing- Linkage Bar 046098300 6 25 End Plug- Damper 251854301 1 26 Lock Collar 049115902 1 27 Bushing- Drive Shaft 043734000 1 122 Actuator, 24V ACT12, 13 113145001 1

Section A2- Outdoor/Return Air w/ Heat Recovery SectionBypass “L” Type Damper Detail

w/ ACT12 (Outside Air) OR ACT13 (Return Air) (Ref. # 230)MicroTech III Controls (Code 12= *E, *F, *W)

Actuator Detail

21

25

20

16

23

12 18

26

27

21

17

13

24

19

122ACT12 OR ACT13

Page 44: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 44

Section A2- Outdoor/Return Air w/ Heat Recovery SectionHeat Recovery/Enthalpy Wheel

Wheel, Motor, Drive Components, Seals

Outdoor Air Out (Supply)

Exhaust Air In (Return) 163161

164

162

165

Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 1 208/230/460V 113073801 1 575V 113087901 1 Segmented Wheel 2 300043261 1 161 Motor 208/230/460V 300043699 1 575V 300043263 1 162 Sheave 111048001 1 163 Bearing 300043258 2 164 Shaft 300043265 1 165 Belt 300043249 1 N/S Inner Seal 300043252 2 N/S Outer Seal 300043252 3N/S= Not Shown on diagram.1 Includes motor, shaft, belt etc.2 If a replacement wheel is required, it is suggested that this part number be used. The segmented wheel ships disassembled which allows for

easier shipping and installation.

Low Air Flow ERW (Code 20= 3E, 5E)- 6” Wheel

Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 1 208/230/460V 113073901 1 575V 113088001 1 Segmented Wheel 2 300043262 1 161 Motor 208/230/460V 300043699 1 575V 300043263 1 162 Sheave 300043260 1 163 Bearing 300043258 2 164 Shaft 300043266 1 165 Belt 300043249 1 N/S Inner Seal 300043252 2 N/S Outer Seal 300043252 3

High Air Flow ERW (Code 20= 4E, 6E)- 12” Wheel

Page 45: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 45

Section A2- Outdoor/Return Air w/ Heat Recovery SectionAFD60 Frost Protection Inverter (Code 24= F)

710

208V

230V

460V

575V

Voltage Ref. Sch. Part Part No. Sym. Description Number 710 Code 23= **A** 1

VFD60 Inverter 2 099488103 1 1 Inverter 2 099488004 1 Inverter 2 112046026 1 Code 23= **B** 1

VFD60 Inverter 2 193552245 1 1 Inverter 2 193552295 1 Inverter 2 193552326 1 Code 23= **Q** 1

VFD60 Inverter 193475806 1 1 Inverter 193475822 1 Inverter 193456302 11 For the fusing for VFD60, refer to the "Energy Recovery Wheel Contactors, MMPs, & Fusing 04/13 & Later" page in

Section N. 2 The replacement VFD Keypad is p/n 300040924.

Heat Wheel

Page 46: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 46

Section A2- Outdoor/Return Air w/ Heat Recovery SectionSection Mounted ControlsOAE, RAE, RAT, EAT, LAT

184

Ref. Part Part Qty. No. Description Number 184 Support- RAT 111077601 1 200 RA Sensor- RAT 193414602 1

RAT- Outdoor Air Temperature Sensor

RA Open-

ing

200

Deck Panel

Return Fan

500 422

600 582

Ref. Part Part Qty. No. Description Number 422 Support- EAT 111077601 1 500 RA Sensor- EAT 193414602 1

EAT- Outdoor Air Temperature Sensor

Ref. Part Part Qty. No. Description Number 582 Support- LAT 111078001 1 600 Sensor- LAT 193414602 1

LAT- Leaving Air Temperature Sensor

40

41

48

42

Economizer Damper

Bottom ReturnShown

Code 19= BY, BE

Bottom ReturnShown

Code 19= BY, BE

Economizer Damper

40

41

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 910146257 1 41 Control- OAE 113103601 1

OAE- Mechanical Enthalpy (Code 17= Y*)

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 910146257 1 41 Control- OAE 113103601 1 42 Mount- RAE Enthalpy 055732301 1 48 Control- RAE 113103701 1

OAE & RAE Differential Enthalpy (Code 17= C*)

Page 47: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 47

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT11 065492402 1 88 Light Switch- S11 065492201 1 89 Receptacle- REC11 030187000 1

LT11- Return Fan Light/S11- Return Fan Light Switch/REC11- Return Fan ReceptacleCode 49= E, F

230

227

Ref. Part Part Qty. No. Description Number 227 Support- SD2 111079701 1 230 Smoke Detector- SD2 098873101 1

SD2- Return Air Smoke DetectorCode 16= 1, 3

Section A2- Outdoor/Return Air w/ Heat Recovery SectionSection Mounted Controls

SD2, HUM1, LT11, S11, REC11

Heat Wheel

RA Opening

RA Opening

596597 Deck

PanelRAT

84

85

88 89

Ref. Part Part Qty. No. Description Number 596 Support- HUM1 12/16 & Earlier 111078101 1 1/17 & Later 910194091 1 597 Humidistat- HUM1 12/16 & Earlier 067295001 1 1 1/17 & Later 910190890 1 1

HUM1- Humidistat (units with frost protection)Code 24= F

1 This is the duct mounted Humidistat. If a unit has a wall mounted Humidistat use p/n 067294901.

Page 48: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 48

Section B- DrawThru Filter/Blank SectionNotes

Primary Codes that pertain: 25, 33, 50Additional Codes that pertain: 06, 19, 20

Code 25 determines the section’s characteristics. If the first digit of Code 25= A, G the Filters are in an angular rack, if the first digit = F the Filters are in a flat rack, or if the first digit = L, S the filters are in a staggered rack. If the second digit = B there are 30% eff. throwaway filters; if C there are 30% eff. throwaway filters with Antimicrobial Intersept; if H there are 85% throwaway filters. If the second digit = D there are 65% eff. filters, if E there are 95% eff. filters, and if G there are 95% eff. filters with Antimicrobial Intersept. If the second digit = Y there is no filter media specified. If Code 25 = BY, EY there is a Blank/Empty section.

Code 33 indicates the presence of a Magnehelic/Differential Filter gauge.

Code 50 indicates the presence of an Air Blender.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank Access Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Codes 19 and 20 determine Return Air section characteristics which has an effect on the final assembly panels.

Ref. Part Part Qty. No. Description Number 65 Pressure Control- PC5 065493801 1

Controls PC5

Section Mounted ControlsPC5, LT13, S13, REC13

Ref. Part Part Qty. No. Description Number 84 Light Fixture 055737501 1 85 Bulb- LT13 065492402 1 88 Light Switch- S13 065492201 1 89 Receptacle- REC13 030187000 1

LT13- Filter Section Light/S13- Filter Section Light Switch/REC13- Filter Section ReceptacleCode 49= E, F84 85

88 89

65

Page 49: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 49

Section B- DrawThru Filter/Blank SectionFilters 1

Ref. Part Code Part Qty. No. Description 25= Number Angular Filter Section (Code 25= A*, D*, E*) N/S Filter 30% Pleated, 16 x 25 x 2" MERV 8 *B 111046306 21 30% Pleated, 16 x 25 x 2" w/ Intersept MERV 8 *C 031298002 21 85% Disposable, 16 x 25 x 2” MERV 13 *H 910102150 21 N/S Filter 30% Pleated, 16 x 20 x 2 MERV 8 *B 111046305 7 30% Disposable, 16 x 20 x 2” w/ Intersept MERV 8 *C 111046505 7 85% Disposable, 16 x 20 x 2” MERV 13 *H 910102152 7 N/S Media Filler Piece ALL 011484101 7 N/S Angle Assembly 2 ALL 056077301 28 Flat Filter Section (Code 25= F*, G*, H*) N/S Filter, Cartridge 65% Cartridge, 24 x 24 x 12" MERV 11 *D 065810704 8 95% Cartridge, 24 x 24 x 12" MERV 14 *E 065810702 8 95% Cartridge, 24 x 24 x 12" w/ Intersept MERV 14 *G 066302252 8 85% Disposable, 24 x 24 x 2” MERV 13 *H 910110394 8 Gasket, Cartridge 5/8 x 1/16 x 24” ALL 021768924 8 N/S Filter, Cartridge 65% Cartridge, 12 x 24 x 12" MERV 11 *D 065810703 4 95% Cartridge, 12 x 24 x 12" MERV 14 *E 065810701 4 95% Cartridge, 12 x 24 x 12" w/ Intersept MERV 14 *G 066302253 4 85% Disposable, 12 x 24 x 2” MERV 13 *H 910110399 4 Gasket, Cartridge 5/8 x 1/16 x 12” ALL 021768912 8 N/S Pre Filter, 24 x 24 x 2” ALL 111046101 8 N/S Pre Filter, 12 x 24 x 2” ALL 111046103 8 Staggered Filter Section (Code 25= L*, S*, T*, V*) 65% Cartridge, 24 x 24 x 12” MERV 11 *D 065810704 8 95% Cartridge, 24 x 24 x 12” MERV 14 *E 065810702 8 95% Cartridge, 24 x 24 x 12” w/ Intersept MERV 14 *G 066302252 8 85% Disposable, 24 x 24 x 2” MERV 13 *H 910110394 8 Gasket, Cartridge 5/8 x 1/16 x 12” ALL 021768912 8 N/S Filter, Cartridge 65% Cartridge, 12 x 24 x 12” MERV 11 *D 065810703 4 95% Cartridge, 12 x 24 x 12” MERV 14 *E 065810701 4 95% Cartridge, 12 x 24 x 12” w/ Intersept MERV 14 *G 066302253 4 85% Disposable, 12 x 24 x 2” MERV 13 *H 910110399 4 Gasket, Cartridge 5/8 x 1/16 x 12” ALL 021768912 8 N/S Pre Filter, 24 x 24 x 2” ALL 111046101 8 N/S Pre Filter, 12 x 24 x 2” ALL 111046103 8

Typical Angular Filter Section Shown

Code 25= A*

1 Note that MERV ratings may change during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters.

2 Optional. Angle is mounted on leaving air side.

Page 50: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 50

Section B- DrawThru Filter/Blank SectionAir Blender Section Components, &

Magnehelic/Differential Pressure Gauge

Ref. Part Code 50= Part Qty. No. Description Number 65 Panel- Access All 059385501 1 68 Air Blender Low CFM L 205139534 2 High CFM H 205139538 2 75 Plate- Econo. Linkage Access All 113047801 2

Air Blender Section Components (Code 50= L, H)

6875

65

Magnehelic/Differential Pressure Gauge(Code 33= A****, B****, C****)

75

3396 Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0- 3” WC 098873203

Page 51: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 51

Section C- DrawThru Blank Access SectionOR Separate Inverter Section

Notes

Primary Codes that pertain: 26, 14, 15Additional Codes that pertain: 06

Code 26 determines if a section is installed and if so, the size of the section. If Code 26= E there is a 24” Blank/Empty section; if Code 26= F there is a Blank 48” section; if Code 26= Y, there is no section.

Codes 14 & 15 determine if the unit has inverter(s) and if so where they are installed. If Code 14= 1, 2, 4 there is a separate Inverter Section. If Code 14= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 14= Y, there are no inverters. Code 15 identifies the inverter brand supplied. All components pertaining to the inverters are listed in the Supply Air Section (Section F).

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank/Empty Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Return Air Inverter (AFD20)

Supply Air Inverter (AFD10)

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT21 065492402 1 88 Light Switch- S21 065492201 1 89 Receptacle- REC21 030187000 1

LT21- DT Access Section Light/S21- DT Access Section Light Switch/REC21- DT Access Section Receptacle84 85

88 89

Section Mounted ControlsLT21, S21, REC21

Page 52: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 52

Section D- DrawThru Cooling SectionNotes

Primary Codes that pertain: 03, 27, 28Additional Codes that pertain: 06

Code 03 determines the DX cooling coil size. If Code 03= S there is a small face area coil in a 24” section; and if Code 03= L there is a large face area coil in a 48” section.

Code 27 determines if there is a Section D. If Code 27= YYYY, then there is no section (for RPS units this indicates that the cooling coil is in the BlowThru position. RDT units always have a section D). If the first three digits of Code 27= DYY then the section contains only a drain pan in a 48” section. If the first three digits of Code 27= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 27= S, the Drain Pan is stainless steel, P in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 27= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 27= L, T, then the first three digits of Code 27 must equal DYY.

Code 28 will apply only if Code 27= CYYY OR CYYS, and determines the DrawThru Coil characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

NOTE: The drawings and components listed in this section also apply to Section I— BlowThru Cooling Section- RPS units.

Page 53: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 53

Small Face Area Coil24” SectionCode 03= S

10

13

43

393

Section D- DrawThru Cooling SectionEvaporator Coils, Drain Pans, Gasketing 1, 2

3

4

43

11

1239

13

39

1037

Ref. Part Part Qty. No. Description Number 3 Coil- Lower Contact Daikin Applied 4 Coil- Upper Contact Daikin Applied 10 Drain Pan Galvanized C27= CYYY 2 056267755 1 Stainless C27= CYYS 2 056267756 1 11 Drain Pan Galvanized C27= CYYY 2 096235001 1 Stainless C27= CYYS 2 055531354 1 12 Pan- Liner 055531202 1 13 Pan- Auxiliary 056271401 1 37 Gasket 056003501 120’ 39 Gasket 049263200 7’ 43 Gasket 021911422 4

48” Section, Large Face Coils (Code 03= L)— Unit Sizes 050- 074 only

Large Face Area Coil48” SectionCode 03= L

24” Section, Small Face Coils (Code 03= S)

1 For Drain Pans and components when Code 27= GYY* AND/OR Code 27= ***L, ***T contact Daikin Applied with model and serial number information so that the required part(s) can be identified.

2 For BlowThru units (Code 35 AND Code 36 CANNOT be all Ys) substitute Code 35 for Code 27. BlowThru and DrawThru Cooling sections use the SAME parts, just the coding is different.

Ref. Part Part Qty. No. Description Number 3 Coil Contact Daikin Applied 10 Drain Pan Galvanized C27= CYYY 2 056267751 1 Stainless C27= CYYS 2 056267752 1 13 Pan- Auxiliary 057356802 1 39 Gasket 049263200 6’ 43 Gasket 021911422 2

Page 54: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 54

Section E- Spacer Section (RPS)Notes

Primary Codes that pertain: 30Additional Codes that pertain: 06

For RPS units Code 30 is normally YYYYYY. If Code 26= EEEEEE there is a 24” Blank/Empty section; if Code 26= FFFFFF then there is a 48” Blank/Empty section.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48” Spacer Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Ref. Part Part Qty. No. Description Number 284 Light Fixture 042229500 1 285 Bulb- LT18 065492402 1 288 Light Switch- S18 065492201 1 289 Receptacle- REC18 030187000 1

LT18- Spacer Section Light/S18- Spacer Section Light Switch/REC18- Spacer Section Receptacle284 285

288 289

Section Mounted ControlsLT18, REC18, S18- Section Mounted Light

Primary Codes that pertain: 04, 30Additional Codes that pertain: 06

Code 04 determines what type of heat has been specified. DrawThru Heat units normally are hydronically heated with Steam (Code 04= S) OR Hot Water (Code 04= W). NOTE: There are some DrawThru Electric Heat RDT units. See Section G [Blow Thru Heat] for all Electric Heat components.

Code 30 determines the Hydronic Heating Coil and associated characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Section E- DrawThru Heat Section (RDT)Notes

Page 55: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 55

3

2

Section E- DrawThru Heat SectionRDT Units

Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM1)(Code 30 first 3 digits = S11, S12, S13, S14, W11, W22)

Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30= Type Height Number 2 Steam Coil- Bottom S11*** 5JA0601H 30” 056053021 1 Steam Coil- Bottom S12*** 5JA1201H 30” 056053022 1 Steam Coil- Bottom S13*** 5JA0602C 30” 056053023 1 Steam Coil- Bottom S14*** 5JA1202C 30” 056053024 1 HW Coil- Bottom W11*** 5WH0901H 30” 404088903 1 HW Coil- Bottom W22*** 5WS0902C 30” 404088904 1 3 Steam Coil- Top S11*** 5JA0601H 27” 056053031 1 Steam Coil- Top S12*** 5JA1201H 27” 056053032 1 Steam Coil- Top S13*** 5JA0602C 27” 056053013 1 Steam Coil- Top S14*** 5JA1202C 27” 056053014 1 HW Coil- Top W11*** 5WH0901H 27” 404088703 1 HW Coil- Top W22*** 5WS0902C 27” 404088704 1 N/S Valve, 2 Way Steam w/ Act.2

1.25” S**E2E 5JA All 113147501 1 1.50” S**F2E 5JA All 113147701 1 2.00” S**G2E 5JA All 113147901 1 2.50” S**H2E 5JA All 113148101 1 163 VM1 Actuator- 24V, 1.25”- 2.00” Valve 1 W****E All All 300046566 1 Actuator- 24V, 2.50”- 3.00” Valve 1 W****E All All 113149601 1 263 Valve, 3 Way HW w/ Actuator 1.25” W**E3E 5WH, 5WS All 113166703 1 1.50” W**F3E 5WH, 5WS All 113166704 1 2.00” W**G3E 5WH, 5WS All 113166705 1 2.50” W**H3E 5WH, 5WS All 113166706 1 3.00” W**J3E 5WH, 5WS All 113166707 1

Coil Location

N/S= Not shown on diagram.1 Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY.2 Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and

serial number information so that the correct Actuator can be identified.

Mixing Valve Detail(HW shown)

163

263

Page 56: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 56

Section F- Supply Air SectionNotes

Primary Codes that pertain: 31, 32, 59, 08, 14, 15, 40, 49Additional Codes that pertain: 04, 06, 16, 17, 23, 33, 34

Code 31 determines the Supply Fan size and type, Code 32 determines the Supply Fan Motor horsepower and type, and Code 59 determines the drive selection. Supply Air Fan Section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information.

Code 08 determines the location of the unit’s Main Control Box. Note that RDT units normally have Main Control Boxes located in the Supply Air Section.

Codes 14 & 15 determine if the unit has inverter(s), and if so where they are installed. If Code 14= Y, there are no inverters. If Code 14= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 14= 1, 2, 4, there is a separate Inverter Section. Code 15 specifies the inverter brand. (Note that the Inverter Compressor ALWAYS has an inverter [VFD/AFD2] located in its’ own Control Box. Codes 14 and 15 DO NOT apply to this inverter.)

Code 40 determines the Discharge Plenum configuration. The Discharge Plenum is located in Section F when the section is bolted directly to the condenser (Section M). RDT units always have the Discharge Plenum located in Section F. If Code 40= BE, there is an Isolation Damper with actuator ACT5. This damper is detailed in Section K.

Code 49 determines if the Supply Air cabinet has a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), OR both (Code 49= C, F).

Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, the location of the Discharge Plenum, as well as the section installed controls.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Code 16 determines if a Smoke Detector is located in the Supply Air Cabinet. If Code 16= 2, 3, a Smoke Detector (SD1) is present.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 17= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 17 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection.

Code 23 indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 115V Service Outlet, and/or Intelligent Equipment.

Code 33 indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 23= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified.

Page 57: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 57

Section F- Supply Air SectionAir Foil Fan- Double Width- RPS Units (Code 31= 27A*, 30A*, 33A*)

Ref. Part Part Fan Size No Description Number 27” 30” 33” 1 Motor- see Supply Air Fan Motor Section 2 Housing Assy. 055527701 1 2A Inlet Funnel Only 031940901 2 2B Cut Off Plate Only 031635800 2 2 Housing Assy. 055527702 1 2A Inlet Funnel Only 031940902 2 2B Cut Off Plate Only 031635900 2 Housing Assy. 055527703 1 2A Inlet Funnel Only 031940903 2 2B Cut Off Plate Only 031636000 2 3 Wheel, Fan- Single Inlet Single Width CW 066543201 1 Wheel, Fan- Single Inlet Single Width CW 066543203 1 Wheel, Fan- Single Inlet Single Width CW 066543205 1 4 Wheel, Fan- Single Inlet Single Width CCW 066543202 1 Wheel, Fan- Single Inlet Single Width CCW 066543204 1 Wheel, Fan- Single Inlet Single Width CCW 066543206 1 5 Screw Adjust Assembly 055528202 2 2 2 11 Shaft- 2.188” Diameter 205982906 1 Shaft- 2.438” Diameter 055582902 1 Shaft- 2.438” Diameter 055515702 1 15 Motor Mount Assembly 056104501 1 1 1 16 Angle- Motor Mount 055514201 1 1 1 17 Holddown 041272900 1 1 2 18 Angle, Clamping 055576601 1 1 21 Key- Fan 9.25” Long X 1/2” Diameter 023221517 1 Key- Fan 9.25” Long X 5/8” Diameter 023221614 1 Key- Fan 4.75” Long X 5/8” Diameter 023221617 2 22 Key- Sheave 6.50” Long X 1/2” Diameter 023221515 1 Key- Sheave 6.50” Long X 5/8” Diameter 023221610 1 1 25 Bearing- Ball 2.187” 020648654 2 Bearing- Ball 2.437” 020648655 2 2

21

42

18

1

17

17

2B

3

2A

16

11

2522

15

5

Page 58: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 58

Section F- Supply Air SectionAir Foil Fan- Single Width- RDT Units

Code 31= 40B1, 40B2, 40B3, 44B1, 44B2, 44B3

Ref. Part Part Fan Size No. Description Number 40” 44” 1 Motor- see Supply Air Fan Motor Section 3 Wheel, Fan- Single Inlet/Single Width 066543243 1 Wheel, Fan- Single Inlet/Single Width 110942010 1 5 Screw Adjust Assembly 055528203 2 2 11 Shaft 2.188” 055615902 1 Shaft 2.438” 055534702 1 15 Mount Assembly-Motor 056104501 1 1 16 Angle -Motor Mount 055514201 1 1 17 Angle, Clamping 055512701 2 2 20 Bearing- Ball 2.187” 020648656 2 Bearing- Ball 2.437” 020648655 2 21 Key- Fan 4.25” Long X 1/2” Diameter 023221519 1 Key- Fan 6.50” Long X 5/8” Diameter 023221610 1 22 Key- Fan 5.50” Long X 1/2” Diameter 023221513 1 Key- Fan 5.50” Long X 5/8” Diameter 023221607 1 24 Tubing- Plastic 021136790 1 Tubing- Plastic 021136795 1 25 Inlet Funnel Assembly 031940905 1 Inlet Funnel Assembly 110941810 1 26 Fitting- 1/8” MPT 027674000 1 1 27 Fitting, Reducer- 1/4” OD X 1/8” FPT 027674100 1 1 28 Fitting 000109800 1 1

243

5

1

11

1622 15

20

25

21

2026

17

2827

Page 59: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 59

Section F- Supply Air SectionFan Mounts- 27” Airfoil Double Width Fan

Code 31= 27A1, 27A2, 27A3

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 27A2 251783201 4 Seismic Code 31= 27A3 251783301 4 161 5- 10 Spring Mount- Green 251784701 1 15- 30 Spring Mount- Dark Brown 251784801 1 40, 50 Spring Mount- Red 251784901 1 162 All Spring Mount- Green 251784701 1 163 5 Spring Mount- Green 251784701 1 7.5, 10 Spring Mount- Dark Brown 251784801 1 15- 30 Spring Mount- Red 251784901 1 40, 50 Spring Mount- Tan 251785001 1 164 All Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 27A2 059992201 12 Seismic Code 31= 27A3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 27A2 112047201 12 Seismic Code 31= 27A3 112047201 20 N/S All Shim Code 31= 27A3 910138495 4

Spring Mounts (Code 31= 27A2) ANDSeismic Spring (Code 31= 27A3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 10 Rubber Mount- Black 021639704 1 15- 50 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Black 021639704 1 63 3, 5, 10 Rubber Mount- Black 021639704 1 7.5, 15- 50 Rubber Mount- Red 021639701 1 64 3- 7.5, 15- 30 Rubber Mount- Black 021639704 1 10, 40, 50 Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 27A1)

Mount Locations61

161or

63

163or

16262 or

16464 or

Rubber Mounts

21

92

91

91

89

81

9361 62

63 64

161 162

163 164

188

189

181

121

Spring Mounts

Seismic strap used only when Code 31= 27A3.

N/S= Not shown on diagram.

Page 60: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 60

Section F- Supply Air SectionFan Mounts- 30” Airfoil Double Width Fan

Code 31= 30A1, 30A2, 30A3

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 30A2 251783201 4 Seismic Code 31= 30A3 251783301 4 161 5 Spring Mount- Green 251784701 1 7.5- 20 Spring Mount- Dark Brown 251784801 1 25- 50 Spring Mount- Red 251784901 1 162 All Spring Mount- Green 251784701 1 163 5, 7.5 Spring Mount- Dark Brown 251784801 1 10- 20 Spring Mount- Red 251784901 1 25- 50 Spring Mount- Tan 251785001 1 164 All Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 30A2 059992201 12 Seismic Code 31= 30A3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 30A2 112047201 12 Seismic Code 31= 30A3 112047201 20

Spring Mounts (Code 31= 30A2) ANDSeismic Spring (Code 31= 30A3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3, 5 Rubber Mount- Black 021639704 1 7.5- 50 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Black 021639704 1 63 3- 30 Rubber Mount- Red 021639701 1 40, 50 Rubber Mount- Green 021639703 1 64 3- 15 Rubber Mount- Black 021639704 1 20- 50 Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 30A1)

Mount Locations61161 or

63163 or

16262 or

16464 or

161 162

163 164

188

189

181

121

Rubber Mounts

Spring Mounts

21

92

91

91

89

81

Seismic strap used only when Code 31= 30A3.

9361 62

63 64

Page 61: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 61

Section F- Supply Air SectionFan Mounts- 33” Airfoil Double Width Fan

Code 31= 33A1, 33A2, 33A3

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 33A2 251783201 4 Seismic Code 31= 33A3 251783301 4 161 5 Spring Mount- Green 251784701 1 7.5- 15 Spring Mount- Dark Brown 251784801 1 20- 40 Spring Mount- Red 251784901 1 50 Spring Mount- Tan 251785001 1 162 All Spring Mount- Green 251784701 1 163 5, 7.5 Spring Mount- Dark Brown 251784801 1 10- 20 Spring Mount- Red 251784901 1 25- 50 Spring Mount- Tan 251785001 1 164 All Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 33A2 059992201 12 Seismic Code 31= 33A3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 33A2 112047201 12 Seismic Code 31= 33A3 112047201 20

Spring Mounts (Code 31= 33A2) ANDSeismic Spring (Code 31= 33A3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 10 Rubber Mount- Black 021639704 1 15- 50 Rubber Mount- Red 021639701 1 62 3, 5 Rubber Mount- Red 021639701 1 7.5- 50 Rubber Mount- Black 021639704 1 63 3- 40 Rubber Mount- Red 021639701 1 50 Rubber Mount- Green 021639703 1 64 All Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 33A1)

Mount Locations61

161or

63

163or

16262 or

16464 or

Rubber Mounts

21

92

91

91

89

81

9361 62

63 64

161 162

163 164

188

189

181

121

Spring Mounts

Seismic strap used only when Code 31= 33A3.

Page 62: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 62

Section F- Supply Air SectionFan Mounts- 40” AFSW- RDT Units

Code 31= 40B1, 40B2, 40B3

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 30 Rubber Mount- Black 021639704 1 40 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Black 021639704 1 63 3- 10 Rubber Mount- Black 021639704 1 15- 40 Rubber Mount- Red 021639701 1 64 All Rubber Mount- Black 021639704 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 40B1)

Mount Locations

61161 or

63163 or

16262 or

16464 or

161 162

163 164

188

189

181

121

Rubber Mounts

Spring Mounts

21

92

91

91

89

81

Seismic strap used only when Code 31= 40B3.

9361 62

63 64

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 40B2 251783201 4 Seismic Code 31= 40B3 251783301 4 161 3- 20 Spring Mount- Green 251784701 1 25- 50 Spring Mount- Dark Brown 251784801 1 162 3- 10, 25, 40, 50 Spring Mount- Yellow 251784601 1 15- 20, 30 Spring Mount- Dark Brown 251784801 1 163 3- 7.5 Spring Mount- Green 251784701 1 10- 20 Spring Mount- Dark Brown 251784801 1 25- 50 Spring Mount- Red 251784901 1 164 3- 25 Spring Mount- Green 251784701 1 25 Spring Mount- Red 251784901 1 40, 50 Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 40B2 059992201 12 Seismic Code 31= 40B3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 40B2 112047201 12 Seismic Code 31= 40B3 112047201 20

Spring Mounts (Code 31= 40B2) ANDSeismic Spring (Code 31= 40B3)

Page 63: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 63

Section F- Supply Air SectionFan Mounts- 44” AFSW- RDT Units

Code 31= 44B1, 44B2, 44B3

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 44B2 251783201 4 Seismic Code 31= 44B3 251783301 4 161 3- 20 Spring Mount- Green 251784701 1 25- 50 Spring Mount- Dark Brown 251784801 1 162 All Spring Mount- Dark Brown 251784801 1 163 3- 7.5 Spring Mount- Green 251784701 1 10- 25 Spring Mount- Dark Brown 251784801 1 30- 50 Spring Mount- Red 251784901 1 164 All Spring Mount- Red 251784901 1 181 All Nut Spring Code 31= 44B2 059992201 12 Seismic Code 31= 44B3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 44B2 112047201 12 Seismic Code 31= 44B3 112047201 20

Spring Mounts (Code 31= 44B2) ANDSeismic Spring (Code 31= 44B3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 25 Rubber Mount- Black 021639704 1 30- 50 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Red 021639701 1 63 3- 10 Rubber Mount- Black 021639704 1 15- 50 Rubber Mount- Red 021639701 1 64 All Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 44B1)

Mount Locations

61161 or

63163 or

16262 or

16464 or

161 162

163 164

188

189

181

121

Rubber Mounts

Spring Mounts

21

92

91

91

89

81

Seismic strap used only when Code 31= 44B3.

9361 62

63 64

Page 64: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 64

H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Code 32= Voltage C32= *EY C32= *JY C32= *HY C32= *KY C09= 12 3 H*Y 208/60/3 039447500 065817100 047358100 065819400 5 J*Y 208/60/3 039447600 065817200 049186800 065819500 7.5 K*Y 208/60/3 037530300 065817300 047665900 065819600 10 L*Y 208/60/3 038999000 065817400 047666100 065819700 15 M*Y 208/60/3 039896200 065817500 049186900 065819800 20 N*Y 208/60/3 039895800 065817600 049187000 065819900 25 P*Y 208/60/3 039448900 065817700 049187100 065820000 30 Q*Y 208/60/3 041775200 205066500 049187200 205066800 40 R*Y 208/60/3 041775300 205067100 049187300 205070700 50 S*Y 208/60/3 041775400 205067500 049187400 205091600 C09= 29 3 H*Y 230/60/3 039442400 065818100 049262300 065820100 5 J*Y 230/60/3 039442500 065818200 040161200 065820200 7.5 K*Y 230/60/3 039448700 065818300 049100500 065820300 10 L*Y 230/60/3 039446500 065818400 044691100 065820400 15 M*Y 230/60/3 039446600 065818500 038689700 065820500 20 N*Y 230/60/3 039448800 065818600 040161300 065820600 25 P*Y 230/60/3 039896100 065818700 040161400 065820700 30 Q*Y 230/60/3 040626800 205066600 049025300 205066900 40 R*Y 230/60/3 041770000 205067200 048448000 205069200 50 S*Y 230/60/3 039899200 205067600 040161600 205069400 C09= 27 3 H*Y 460/60/3 039442400 065818100 049262300 065820100 5 J*Y 460/60/3 039442500 065818200 040161200 065820200 7.5 K*Y 460/60/3 039448700 065818300 049100500 065820300 10 L*Y 460/60/3 039446500 065818400 044691100 065820400 15 M*Y 460/60/3 039446600 065818500 038689700 065820500 20 N*Y 460/60/3 039448800 065818600 040161300 065820600 25 P*Y 460/60/3 039896100 065818700 040161400 065820700 30 Q*Y 460/60/3 040626800 205066600 049025300 205066900 40 R*Y 460/60/3 041770000 205067200 048448000 205069200 50 S*Y 460/60/3 039899200 205067600 040161600 205069400 C09= 37 3 H*Y 575/60/3 046741600 046511700 049188300 046514500 5 J*Y 575/60/3 046741900 205168900 049188400 046514600 7.5 K*Y 575/60/3 047443300 205168800 049188500 046514700 10 L*Y 575/60/3 047443400 205168600 049188600 065821400 15 M*Y 575/60/3 047443500 205166600 049185200 065821500 20 N*Y 575/60/3 049181100 205166800 049188700 065821600 25 P*Y 575/60/3 049181200 205166900 049188800 065821700 30 Q*Y 575/60/3 049181300 205066700 049188900 205067000 40 R*Y 575/60/3 049181400 205067300 049189000 205069300 50 S*Y 575/60/3 049181500 205091800 049189100 205069500

Section F- Supply Air SectionSupply Air Fan Motors

Standard Motors: Code 32= **Y

Page 65: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 65

Section F- Supply Air SectionSupply Air Fan Motors

Shaft Grounded Motors: Code 32= **S

H.P. Motor HP Unit ODP PrEff. TEFC PrEff C32= **S Voltage C32= *JS C32= *KS C09= 12 3 H*S 208/60/3 300052109 065819499 5 J*S 208/60/3 300052118 065819599 7.5 K*S 208/60/3 065817399 065819699 10 L*S 208/60/3 065817499 065819799 15 M*S 208/60/3 065817599 065819899 20 N*S 208/60/3 065817699 065819999 25 P*S 208/60/3 065817799 065820099 30 Q*S 208/60/3 205066599 205066899 40 R*S 208/60/3 205067199 205070799 50 S*S 208/60/3 205067599 205091699 C09= 29 3 H*S 230/60/3 300049698 300049688 5 J*S 230/60/3 300049699 300049689 7.5 K*S 230/60/3 300049700 300049690 10 L*S 230/60/3 300049701 065820499 15 M*S 230/60/3 065818599 300049198 20 N*S 230/60/3 065818699 300049691 25 P*S 230/60/3 300049702 300049692 30 Q*S 230/60/3 300049703 205066999 40 R*S 230/60/3 300049704 300049693 50 S*S 230/60/3 300049705 300049694 C09= 27 3 H*S 460/60/3 300049698 300049688 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 10 L*S 460/60/3 300049701 065820499 15 M*S 460/60/3 065818599 300049198 20 N*S 460/60/3 065818699 300049691 25 P*S 460/60/3 300049702 300049692 30 Q*S 460/60/3 300049703 205066999 40 R*S 460/60/3 300049704 300049693 50 S*S 460/60/3 300049705 300049694 C09= 37 3 H*S 575/60/3 046511799 205168499 5 J*S 575/60/3 205168999 046514699 7.5 K*S 575/60/3 205168899 046514799 10 L*S 575/60/3 205168699 065821499 15 M*S 575/60/3 205166699 065821599 20 N*S 575/60/3 205166899 065821699 25 P*S 575/60/3 205166999 065821799 30 Q*S 575/60/3 098865399 205067099 30 Q*S 575/60/3 098865399 205067099 40 R*S 575/60/3 205067399 205069399 50 S*S 575/60/3 205091899 205069599

Page 66: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 66

Section F- Supply Air SectionBelt Guards

Code 49= A, C, D, F

Ref. Part Part Fan Size No. Description Number 27” 30” 33” 40 Grille Assembly 055606001 1 Grille Assembly 055606002 1 Grille Assembly 055606003 1 41 Belt Guard Assembly 055606011 1 Belt Guard Assembly 055606012 1 Belt Guard Assembly 055606013 1

Air Foil Double Width (AFDW)

41

40

Air Foil Single Width (AFSW) with Side Discharge (Code 40= H),

Main Control Box (Code 08= S, F)

81

80

Air Foil Single Width (AFSW) with Side Discharge (Code 40= S),

No Control Box (Code 08= P, D)

81

80

82

Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= G),Main Control Box (Code 08= S, F)

81

80

The Main Control Box is mounted in this section on RDT units.

83

Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= B),

No Control Box (Code 08= P, D, Y)

81

80

Ref. Part Part Fan Size No. Description Number 40” 44” 80 Grille Assy 056259201 1 1 81 Grille Assy 056259202 1 1 82 Grille Assy 056259203 1 1 83 Grille Assy 056259204 1 1

RPS units (Main Control Box is mounted in the Discharge Plenum Section K).

82

RPS units (Main Control Box is mounted in the Discharge Plenum Section K).

The Main Control Box is mounted in this section on RDT units.

83

Page 67: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 67

Section F- Supply Air SectionInverters & Inverter Bypass Control Box

Motor HP 2- 5 (Code 22= G**, H** , J**; OR Code 32= H**, J**)

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP30/40 & M30/40 Link Detail2 HP Motor- All Voltages3, 5 HP Motors- 460/575V

MMP30/40 & M30/40 Link Detail3, 5 HP Motors- 208/230V

MMP

70B

Contactor72

7070APhase Barrier

Spacer72A

70APhase Barrier

Front Mtd.Aux. Contact

Link 70C

Motor Horsepower 2 3 5

Ref. Sch. Part Part No. Sym. Description Number 40 VFD10, 20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30, 40 Motor Protector 193542907 1 193542908 1 193542910 1 1 193542911 1 193542912 1 1 1 193543007 1 1 193543009 1 1 70A Phase Barrier 193545501 1 1 1 1 1 1 1 1 1 1 1 1 70B Aux. Contact 193543801 1 1 1 1 1 1 1 1 1 1 1 70C Link 193545901 1 1 1 1 193546001 1 1 1 1 71 LR10, 20 Line Reactor- see page after Inverters

72 M30B, I Contactor 193592105 1 1 M40B, I 193592106 1 193539105 1 1 1 1 1 1 193539106 1 1 193539304 1 72A Spacer 193545801 2 2 2 2

50

40

Supply Air OR Return Air Fan Inverter w/ Bypass Control Box shown.

(Code 14= 3, 5, 8)Two boxes installed if Code 14= 5

MMP30 (Supply)MMP40 (Return)

7071

72

Bypass Controls Detail

LR10 (Supply)LR20 (Return)

M30B/M30I (Supply)M40B/M40I (Return)

40 40

Supply Air and Return Air Fan

Inverter without Bypass.

(Code 14= 7)

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 6, 7, 9)

Page 68: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 68

50

40

Supply Air OR Return Air Fan Inverter w/ Bypass Control

Box.(Code 14= 5, 8)

Two boxes installed if C14= 5

Section F- Supply Air SectionInverters & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 OR Code 32= K**, L**, M**, N**, P**)Diagrams

40

Supply Air and Return Air Fan

Inverter without Bypass.

(Code 14= 7)

40

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 7, 9)

70

71

72

Bypass Controls Detail

MMP40 (Return)

LR10 (Supply)

M30B/M30I (Supply)

LR20 (Return)

71

MMP30 (Supply)

70

72M40B/M40I (Return)

MMP30/40 & M30/40 Link Detail7.5 HP Motors- 208/230/460V

10, 15 HP Motors- 460V

MMP

70B

Contactor72

70

Spacer72A

70APhase Barrier

Front Mtd.Aux. Contact

Link 70C

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP30/40 & M30/40 Link Detail7.5 HP Motors- 575V

70APhase Barrier

MMP30/40 & M30/40 Link Detail10, 15 HP Motors- 208/230V

15, 20 HP Motors- 575V 20 HP Motors- 460V

25 HP Motors- 460/575V

MMP30/40 & M30/40 Link Detail20, 25 HP Motors- 208/230V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B70APhase Barrier

Page 69: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 69

Section F- Supply Air SectionInverters & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 OR Code 32= K**, L**, M**, N**, P**)Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Motor Horsepower 7.5 10 15 20 25

Ref. Sch. Part Part No. Sym. Description Number 40 AFD10, 20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30 ,40 Motor Protector 193542913 1 193543008 1 1 193543009 1 193543010 1 193543011 1 193543012 1 193543301 1 193543303 1 193543304 1 1 1 1 1 193543305 1 193543306 1 193543403 1 1 1 193543404 1

70A Phase Barrier 193545501 1 1 1 1 1 1 1 193547301 1 1 1 1

70B Contact- Auxiliary 193543801 1 1 1 1 1 1 1 193546201 1 1 1 1 1 1 1 1 1 1 1 1 1

70C Link 193545901 1 193546001 1 1 1 1 1 1 193547401 1 1 1 1 1 1 1 1 1 193547501 1 1 1 1 71 LR10, 20 Line Reactor- see page after Inverters 72 M30B, I M40B, I Contactor 9A 193539106 1 12A 193592105 1 1 16A 193592106 1 25A 193539304 1 1 1 1 1 32A 193539501 1 1 1 1 1 50A 193539502 1 1 65A 193539601 1 1 80A 193539602 1 1

72A Spacer 193545801 2 2 2 2 2 2

Page 70: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 70

Section F- Supply Air SectionInverters & Inverter Bypass Control Box

Motor HP 30- 50 (Code 22= Q** OR Code 32= Q**, R**, S**)Diagrams

50

40

Supply Air OR Return Air Fan Inverter w/ Bypass Control Box.

(Code 14= 5, 8)Two boxes installed if Code 14= 5

40

Supply Air and Return Air Fan

Inverter without Bypass.

(Code 14= 7)

40

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 7, 9)

70

71

72

Bypass Controls Detail

MMP40 (Return)

LR10 (Supply)

M30B/M30I (Supply)

LR20 (Return)

71

MMP30 (Supply)

70

72M40B/M40I (Return)

MMP30/40 & M30/40 Link Detail30 HP Motors- 460/575V

40 HP Motors- 575V

MMP30/40 & M30/40 Link Detail30 HP Motors- 208/230V

40 HP Motors- 460V50 HP Motors- 460/575V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

70APhase Barrier

79

78

Contactors

Overload

Interlock

MMP30/40 & M30/40 Link Detail40, 50 HP Motors- 208/230V

72

Page 71: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 71

Section F- Supply Air SectionInverters & Inverter Bypass Control Box

Motor HP 30- 50 (Code 22= Q** OR Code 32= Q**, R**, S**)Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Motor Horsepower 30 40 50

Ref. Sch. Part Part No. Sym. Description Number 40 AFD10, 20 Inverter- see next page

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30 Motor Protector MMP40 70- 90A 193543405 1 1 45- 63A 193543403 1 36- 50A 193543402 1 1 28- 40A 193543305 1 1 22- 32A 193543304 1

70A Phase Barrier 193547301 1 1 1 1 1

70B Contact- Auxiliary 193546201 1 1 1 1 1 1 1 1

70C Link 193547501 1 1 1 1 1 193547401 1 1 1

71 LR10 ,20 Line Reactor- see page after Inverters

72 M30B,I Contactor 150A 193591802 2 2 M40B,I 115A 193591801 2 2 95A 193539603 1 80A 193539602 1 65A 193539601 1 1 1 50A 193539502 1 40A 193539501 1 1

78 OL30 Overload 50- 200A 193549702 1 1 1 OL40 80- 100A 193548608 1

79 Mechanical Interlink 193582601 1 1 1 1

N/S CB30, 40 Circuit Breaker 150A 193550302 1 1 1 1 N/S= Not Shown on Diagram.

Page 72: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 72

Section F- Supply Air SectionInverters

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50

Part Number 098861454 1 098861455 1 098861456 1 098861457 1 098861458 1 098861459 1 098861460 1 098861461 1 098861462 1 098861467 1 1 098861468 1 098861469 1 098861470 1

208/

230V

460V

208/

230V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

Code 15= R

Page 73: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 73

Motor Horsepower 2, 3 5 7.5 10 15 20 25 30 40 50

Part Number 099488004 1 099488103 1 193552326 1 099488005 1 099488104 1 193552327 1 099488006 1 099488105 1 193552328 1 099488007 1 099488106 1 193552329 1 099488008 1 099488107 1 193552330 1 193552319 1 099488108 1 193552331 1 193552320 1 099488109 1 193552332 1 193552321 1 099488110 1 193552333 1 193552322 1 193552309 1 193552334 1 193552323 1 193552310 1 193552335 1

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

Code 15= A 1

Section F- Supply Air SectionInverters, Continued

1 The replacement VFD Keypad Display is p/n 300040924.

Page 74: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 74

Section F- Supply Air SectionInverters, Continued

Motor Horsepower 2 3 5 7.5 10 15 20 25

Part Number 098656901 1 098656902 1 098656903 1 098656904 1 098656905 1 098656906 1 098656907 1 098656908 1 098656914 1 098656915 1 098656916 1 098656917 1 098656918 1 098656919 1 098656920 1 098656921 1 098656924 1 098656925 1 098656926 1 098656927 1 098656928 1 098656929 1 098656930 1 098656931 1 098656943 1 1 1 098656944 1 098656945 1 098656946 1 098656947 1 098656948 1

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

208V

230V

460V

575V

Code 15= G

Motor Horsepower 30 40 50

Part Number 098656909 1 098656910 1 098656911 1 098656922 1 098656923 1 098656940 1 098656932 1 098656933 1 098656953 1 098656951 1

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Page 75: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 75

Code 15= S, Q

Section F- Supply Air SectionInverters, Continued

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50

Part Number 193475806 1 1 193475807 1 1 193475809 1 1 193475810 1 1 193475811 1 1 193475812 1 1 193475813 1 1 193475814 1 1 193475815 1 1 193475816 1 1 349956617 3 1 193475822 1 1 193475823 1 1 193475825 1 1 193475826 1 1 193475827 1 1 193475828 1 1 193475829 1 1 193475830 1 1 193475831 1 1 193475832 1 1 193475883 1 1 193456302 2,4 1 193456303 2,4 1 193456304 2,4 1 193456305 2,4 1 193456306 2,4 1 193456307 2,4 1 193456308 2,4 1 349956647 3 1 349956648 3 1 349956649 3 1 349956650 3 1

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

1 The Remote Keypad is p/n 349958805 and the Remote Keypad Mounting kit is p/n 349958803. The Lonworks communication card is p/n 193482601. All other communication cards are integral to the VFD and are not available separately.

2 MD3 Remote Keypad p/n is 349958802.3 MD6 Remote Keypad p/n is 349958805 plus Mount p/n 349958803.4 For 575V units with an MD3 Inverter and Motor under 25 HP a Line Reactor will be installed regardless of whether one is specified in Code

17 (see nomenclature page). See one page after next for Line Reactor part numbers.

Page 76: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 76

Section F- Supply Air SectionInverters, Continued

Code 15= B (MD4, MD5) 1

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50

Part Number 193552245 1 193552295 1 193552326 1 1 193552246 1 193552296 1 193552215 1 193552202 1 193552327 1 193552216 1 193552203 1 193552328 1 193552217 1 193552204 1 193552329 1 193552218 1 193552205 1 193552330 1 193552319 1 193552206 1 193552331 1 193552320 1 193552207 1 193552332 1 193552321 1 193552208 1 193552333 1 193552322 1 193552309 1 193552334 1 193552323 1 193552310 1 193552335 11 The replacement VFD Keypad Display is p/n 300040924.

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208/

230V

460V

575V

Page 77: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 77

Section F- Supply Air SectionLine Reactors 1

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50

Part Number 073323502 1 073323503 1 073323504 1 073323505 1 073323506 1 073323507 1 073323508 1 073323509 1 073323511 1 073323512 1 073323517 1 073323518 1 073323519 1 073323520 1 073323521 1 073323522 1 073323523 1 073323533 1 073323534 1 073323535 1 073323541 1 3499649262 1 3499649272 1 3499649292 1 3499649302 1 3499649312 1 3499649322 1 3499649532 1 1 3499649542 1 3499649552 1 3499649562 1

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

1 Line Reactors are used when Code 17= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7,, Y8; except for MD3 575V Inverters (Code 15= S, Q ) 2- 20 HP. These will always have a Line Reactor installed regardless of Code 17.

2 These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation.

Page 78: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 78

Section F- Supply Air SectionSection Mounted Controls

PC7, HL22, LT10, S10, REC10, UV Lights

67 Ref. Part Part Qty. No. Description Number 67 T-stat- HL22 Hi Limit 047938801 1

HL22- Gas Heat Hi Limit SwitchCode 04= A

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT10 065492402 1 86 Junction Box 065491901 1 87 Junction Box Cover 065492001 1 88 Light Switch- S10 065492201 1 89 Receptacle- REC10 030187000 1

LT10- Supply Fan Light/S10- Supply Fan Light Switch/REC10- Supply Fan ReceptacleCode 49= B, E

98

99

Ref. Part Part Qty. No. Description Number 98 Light Fixture- 18” Bulb 205484001 1 Light Fixture- 24” Bulb 205484101 1 Light Fixture- 36” Bulb 205484201 1 99 Bulb/Lamp, UV- 18” 205484501 1 Bulb/Lamp, UV- 24” 205484601 1 Bulb/Lamp, UV- 36” 205484701 1

UV LightsCode 17= C1 thru C8, Y1 thru Y8

19

15

20

84 85

86 87

88 89

Ref. Part Part Qty. No. Description Number 15 Bracket 910122290 1 19 Pressure Control- PC7 910115489 1 20 Pneumatic Fitting 910122414 1

PC7- Proof of Airflow Pressure Control

Page 79: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 79

Section F- Supply Air SectionSection Mounted Controls

MAT, EFT, SAT, DAT, OAT, SD1

50

51

Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD1 098873101 1 51 Sensing Tube 049025002 1

Smoke Detector- SD1Code 16= 2, 3

Ref. Part Part Qty. No. Description Number 7 OAT Temp. Sensor 193414602 1

Outdoor Air Temperature Sensor- OAT7

8

OAT

DAT

Smoke Detector

Detail

Ref. Part Part Qty. No. Description Number 8 SAT/DAT Temp. Sensor 193414602 1

Supply Air Temperature Sensor- SAT ORDischarge Air Temperature Sensor- DAT

5

EFT

Ref. Part Part Qty. No. Description Number 5 EFT/MAT Temp. Sensor 193414602 1

Mixed Air Temperature Sensor- MAT OREntering Fan Temperature Sensor- EFT

Page 80: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 80

Section F- Supply Air SectionSection Mounted Controls

SCB- Split Junction Box (Code 05= F) TB25, TB27, TB28, PB10, PB9, PB20, PB19

TB28 TB27 TB25

PB 19 PB 20 PB 9 PB 10

Motor HP 2- 25 30 40, 50 Sch. Part Part Sym. Description Number Terminal Blocks TB25 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 TB27 Terminal Block- SCB 015998130 1 1 1 1 1 1 1 1 1 1 1 1 TB28 1 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 PB10 Power Block- Supply Fan 95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1 PB9 Power Block- Supply Fan 95A, 600V, 3P 030372707 1 PB20 Power Block- Return Fan 95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 PB19 Power Block- Return Fan 95A, 600V, 3P 030372707 1

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

1 Only used when the unit has a supply fan inverter OR an Economizer with a Power Closure Exhaust Damper.

Page 81: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 81

Section G- BlowThru Heat SectionNotes

Primary Codes that pertain: 04, 34Additional Codes that pertain: 06, 07, 09, 12, 31

This section is divided into four subsections: 1. Blank/Empty section; 2. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat.

Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section’s characteristics. If Code 04= Y, and Code 34= YYYYYY there is no section. If Code 04= Y and Code 34= BBBBBB, then there is a 48” Blank Access Section installed. Otherwise, see the Nomenclature, Unit Code Index section for specific heat section definitions.

Code 06 determines the insulation and liners and will affect the Top Panel, Uprights, and Door Assembly part numbers. For sheet metal components that make up the BlowThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is ETA/MEA approved (USA) OR ETL approved (Canada).

Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls. Code 12 determines the Control type and will affect the Gas Heat Actuator. Code 31 is the Supply Fan size, and affects the heat section’s Diffusers.

Option 1: Blank SectionCode 34= BBBBBB AND Code 04= Y

Diffuser

12

Ref. Part Part Qty. No. Description Number 12 Diffuser 27” Supply Fan Code 31= 27** 055988001 1 30” Supply Fan Code 31= 30** 055988002 1 33” Supply Fan Code 31= 33** 055988003 1

Page 82: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 82

3

2

Section G- BlowThru Heat SectionOption 2: Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM1)

Code 34 first 3 digits = S11, S12, S13, S14, W11, W22

Coil Location Mixing Valve Detail(HW shown)

12

Diffuser

163

263

Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number 2 Steam Heat Coil- Bottom S11*** 5JA0601H 30” 056053021 1 Steam Heat Coil- Bottom S12*** 5JA1201H 30” 056053022 1 Steam Heat Coil- Bottom S13*** 5JA0602C 30” 056053023 1 Steam Heat Coil- Bottom S14*** 5JA1202C 30” 056053024 1 Hot Water Heat Coil- Bottom W11*** 5WH0901H 30” 056053025 1 Hot Water Heat Coil- Bottom W22*** 5WS0902C 30” 056053026 1 3 Steam Heat Coil- Top S11*** 5JA0601H 27” 056053031 1 Steam Heat Coil- Top S12*** 5JA1201H 27” 056053032 1 Steam Heat Coil- Top S13*** 5JA0602C 27” 056053013 1 Steam Heat Coil- Top S14*** 5JA1202C 27” 056053014 1 Hot Water Heat Coil- Top W11*** 5WH0901H 27” 056053035 1 Hot Water Heat Coil- Top W22*** 5WS0902C 27” 056053016 1 N/S FS1 Freezestat ALL ALL ALL 072502001 1 12 Diffuser- 27” Supply Fan 055988001 1 Diffuser- 30” Supply Fan 055988002 1 Diffuser- 33” Supply Fan 055988003 1 N/S Valve, 2 Way Steam Heat w/ Act.2

1.25” S**E2E 5JA All 113147501 1 1.50” S**F2E 5JA All 113147701 1 2.00” S**G2E 5JA All 113147901 1 2.50” S**H2E 5JA All 113148101 1 163 VM1 Actuator- 24V, 1.25”- 2.00” Valve 1 W****E All All 300046566 1 Actuator- 24V, 2.50”- 3.00” Valve 1 W****E All All 113149601 1 263 Valve, 3 Way HW w/ Actuator 1.25” W**E3E 5WH, 5WS All 113166703 1 1.50” W**F3E 5WH, 5WS All 113166704 1 2.00” W**G3E 5WH, 5WS All 113166705 1 2.50” W**H3E 5WH, 5WS All 113166706 1 3.00” W**J3E 5WH, 5WS All 113166707 1 N/S= Not shown on diagram.1 Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY.2 Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and

serial number information so that the correct Actuator can be identified.

Page 83: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 83

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit= E

Heaters, Diffusers, Hi Limit Cutouts HL1- 20, 31- 50Diagram & Components

6

5

12

7

Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout 1 Only 2

5 Heater Assy- Top 40 E040 40 049269208 049269217 1 Heater Assy- Top 40 E040 40 049269226 049269235 1 Heater Assy- Top 40 E040 40 N/A 049269244 1 Heater Assy- Top 60 E060 60 049269207 049269216 1 Heater Assy- Top 60 E060 60 049269225 049269234 1 Heater Assy- Top 60 E060 60 N/A 049269243 1 Heater Assy- Top 80 E080 80 049269206 049269215 1 Heater Assy- Top 80 E080 80 049269224 049269233 1 Heater Assy- Top 80 E080 80 N/A 049269242 1 Heater Assy- Top 100 E100 100 049269205 049269214 1 Heater Assy- Top 100 E100 100 049269223 049269232 1 Heater Assy- Top 100 E100 100 N/A 049269241 1 Heater Assy- Top 120 E120 120 049269204 049269213 1 Heater Assy- Top 120 E120 120 049269222 049269231 1 Heater Assy- Top 120 E120 120 N/A 049269240 1 Heater Assy- Top 160 E160 160 049269203 049269212 1 Heater Assy- Top 160 E160 160 049269221 049269230 1 Heater Assy- Top 160 E160 160 N/A 049269239 1 Heater Assy- Top 200 E200 120 049269201 049269210 1 Heater Assy- Top 200 E200 120 049269219 049269228 1 Heater Assy- Top 200 E200 120 N/A 049269237 1 Heater Assy- Top 240 E240 120 049269201 049269210 1 Heater Assy- Top 240 E240 120 049269219 049269228 1 Heater Assy- Top 240 E240 120 N/A 049269237 1

208/

230V

460V

575V

7A

N/A= Not Applicable.1 Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches.2 Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches.

Air

Flow

Page 84: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 84

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit= E

Heaters, Diffusers, Hi Limit Cutouts HL1- 20, 31- 50Components, Continued

Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout 1 Only 2

6 Blank Assy- Bottom 40- 160 E/040- 160 055923601 055923601 1 1 1 Heater Assy- Bottom 200 E200 80 049269202 049269211 1 Heater Assy- Bottom 200 E200 80 049269220 049269229 1 Heater Assy- Bottom 200 E200 80 N/A 049269238 1 Heater Assy- Bottom 240 E240 120 049269201 049269210 1 Heater Assy- Bottom 240 E240 120 049269219 049269228 1 Heater Assy- Bottom 240 E240 120 N/A 049269237 1 7 HL1-20 Hi Limit- Manual Cutout All All All 065496201 N/A var var var 7A HL31-50 Hi Limit- Auto Cutout All All All 065824501 065824201 var var var 12 Diffuser All All All 055645701 055645201 1 1 1

208/

230V

460V

575V

N/A= Not Applicable.1 Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches.2 Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches.

Page 85: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 85

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = E

Electric Heat Control BoxDiagrams & Components

208/230V20KW- 160KW

460/575V20KW- 160KW

460/575V200KW- 240KW

FB33 FB37 FB32 FB36 FB31 FB35

M33 M37 M32 M36 M31 M35

M34 M38

FB34 FB38

HS3

DS3or

PB3

FB33 FB32 FB31

FB34

M33

M34

M32 M31

HS3

DS3or

PB3

TB11

FB33 FB32 FB31

FB41

M33

M41

M32 M31

HS3

DS3or

PB3

FB42FB43

M42M43

TB11

TB11

PB31 PB31 PB31

Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 100A 193444703 Not Used 193422102 193596420 2 Not Used Disconnect Switch- 150A 193585101 193550801 193422102 193596420 2 193553301 4

Disconnect Switch- 250A 193551601 193551001 193595701 300049193 3 193553801 4

Disconnect Switch- 400A 193551701 193551001 193595701 300049193 3 193554001 4

Disconnect Switch- 600A 193551801 193551001 193595701 300049193 3 193554101 4

DS3- Disconnect Switch 1

1 Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified.

2 This Shaft is 14.25” OAL and is designed to be cut to length in the field.3 This Shaft is 7.21” (183mm) OAL and is designed to be cut to length in the field. For a 19.69” (500mm) OAL use p/n 300040299.4 Three Lugs are included with each p/n.

Page 86: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 86

Heater KW= 20 40 60 80 100 120 Sch. Part Part Sym. Description Number PB3 Power Block 175A 030372777 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Power Block 420A 030372785 1 1 1 1 1 1 1 1

PB31 Power Block 3 used w/100A, 150A DS3 030372777 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/250A DS3 030372783 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/400A DS3 030372785 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/600A DS3 030372721 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

DS3 Disconnect Switch 2

HS3 Switch 033696300 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

M31 Contactor 40A 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M32 Contactor 40A 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M33 Contactor 40A 193591601 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M34 Contactor 40A 193591601 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M35 Contactor 40A 193591601 1 1 1 1 M36 Contactor 40A 193591601 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = E

Electric Heat Control Box20- 120KW Components

1 Part number is for one section. The number of sections used is determined by the options installed.2 See the chart on the previous page.3 Not Used when PB3 Power Block connection is present.4 Cover- PB31 used with 600A DS3 is p/n 349938345.

Page 87: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 87

Heater KW= 20 40 60 80 100 120 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB32 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 Fuse Block 023780230 1 1 1 1 FB33 Fuse Block 023780229 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 FB34 Fuse Block 023780229 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 FB35 Fuse Block 023780229 1 1 1 1 FB36 Fuse Block 023780229 1 1

F31 Fuse- FB31 025860514 3 3 3 3 3 3 3 3 3 3 Fuse- FB31 025860511 3 Fuse- FB31 025860512 3 Fuse- FB31 025860409 3 3 3 Fuse- FB31 025860408 3 3 3 Fuse- FB31 025860412 3 Fuse- FB31 025860411 3 Fuse- FB31 025860414 3 3 Fuse- FB31 025860413 3 3 F32 Fuse- FB32 025860514 3 3 3 3 3 3 3 3 Fuse- FB32 025860511 3 Fuse- FB32 025860512 3 Fuse- FB32 025860409 3 3 3 Fuse- FB32 025860408 3 3 3 Fuse- FB32 025860412 3 Fuse- FB32 025860411 3 Fuse- FB32 025860414 3 Fuse- FB32 025860413 3 F33 Fuse- FB33 025860511 3 Fuse- FB33 025860512 3 Fuse- FB33 025860514 3 3 3 3 3 3 Fuse- FB33 025860409 3 3 3 Fuse- FB33 025860408 3 3 3 F34 Fuse- FB34 025860511 3 Fuse- FB34 025860512 3 Fuse- FB34 025860514 3 3 3 3 3 3 Fuse- FB34 025860409 3 3 3 Fuse- FB34 025860408 3 3 3 F35 Fuse- FB35 025860514 3 3 3 3 F36 Fuse- FB36 025860514 3 3

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = E

Electric Heat Control Box20- 120KW Components, Continued

Page 88: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 88

Heater KW= 160 200 240 Sch. Part Part Sym. Description Number PB3 Power Block 030372785 1 1 1 1 Power Block 030372786 1 1 1 1 PB31 Power Block 3 used w/100A/150A DS3 030372777 1 1 1 1 1 1 1 1 used w/250A DS3 030372783 1 1 1 1 1 1 1 1 used w/400A DS3 030372785 1 1 1 1 1 1 1 1 used w/600A DS3 030372721 4 1 1 1 1 1 1 1 1 DS3 Disconnect Switch 2

HS3 Switch 033696300 1 1 1 1 1 1 1 1 TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1

M31 Contactor 40A 193591601 1 1 1 1 1 1 1 1 M32 Contactor 40A 193591601 1 1 1 1 1 1 1 1 M33 Contactor 40A 193591601 1 1 1 1 1 1 1 1 M34 Contactor 40A 193591601 1 1 1 1 M35 Contactor 40A 193591601 1 1 M36 Contactor 40A 193591601 1 1 M37 Contactor 40A 193591601 1 1 M38 Contactor 40A 193591601 1 1 M41 Contactor 40A 193591601 1 1 M42 Contactor 40A 193591601 1 1 M43 Contactor 40A 193591601 1 1

208V

230V

460V

575V

460

V57

5V 4

60V

575V

1 Part number is for one section. The number of sections used is determined by the options installed.

2 See chart 3 pages prior.3 Not Used when PB3 Power Block connection is present.4 Cover- PB31 for 600A DS3= p/n 349938345.

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = E

Electric Heat Control Box160- 240KW Components

Page 89: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 89

Heater KW= 160 200 240 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB32 Fuse Block 023780229 1 1 Fuse Block 023780225 Fuse Block 023780230 1 1 1 1 1 1 FB33 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB34 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 FB35 Fuse Block 023780229 1 1 FB36 Fuse Block 023780229 1 1 FB37 Fuse Block 023780229 1 1 FB38 Fuse Block 023780229 1 1 FB41 Fuse Block 023780230 1 1 1 1 FB42 Fuse Block 023780230 1 1 1 1 FB43 Fuse Block 023780230 1 1

F31 Fuse- FB31 025860514 3 3 Fuse- FB31 025860414 3 3 3 Fuse- FB31 025860413 3 3 3 F32 Fuse- FB32 025860514 3 3 Fuse- FB32 025860414 3 3 3 Fuse- FB32 025860413 3 3 3 F33 Fuse- FB33 025860514 3 3 Fuse- FB33 025860414 3 3 3 Fuse- FB33 025860413 3 3 3 F34 Fuse- FB34 025860514 3 3 Fuse- FB34 025860414 3 Fuse- FB34 025860413 3 F35 Fuse- FB35 025860514 3 3 F36 Fuse- FB36 025860514 3 3 F37 Fuse- FB37 025860514 3 3 F38 Fuse- FB38 025860514 3 3 F41 Fuse- FB41 025860414 3 3 Fuse- FB41 025860413 3 3 F42 Fuse- FB42 025860414 3 3 Fuse- FB42 025860413 3 3 F43 Fuse- FB43 025860414 3 Fuse- FB43 025860413 3

208V

230V

460V

575V

460

V57

5V 4

60V

575V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = E

Electric Heat Control Box160- 240KW Components, Continued

Page 90: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 90

Section G- BlowThru Heat SectionOption 4- Gas Heat Code 04= AHeat Exchangers & Vestibules

200, 250 MBH Furnaces Code 34= 020**, 025**

Ref. Part 200, 250 Qty. No. Description MBH 1 Heat Exchanger Kit 098322511 1 21 Vestibule 055636308 1 22 Vestibule 055636303 1 38 Capillary Plate 059360301 1 N/S Turbulator Assy. 034150401 4 8N/S= Not shown on diagram.1 Parts detail follows this section.2 Parts detail follows Burner section.3 Parts detail follows Burner Control Box section.4 Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulator Assemblies must be ordered separately.

38

21

22

HeatExchanger

Burner 1

BurnerControlBox 2

Gas Train 3

1

Page 91: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 91

Section G- BlowThru Heat SectionOption 4- Gas Heat Code 04= AHeat Exchangers & Vestibules

320, 400, 500, 640, 650, 790, 800, 1000 MBH FurnacesCode 34= 032**, 040**, 050**, 064**, 065**, 079**, 080**, 100**

Ref. Part 320, 400 500, 640 650, 790 800, 1000 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger Kit 098322512 098322513 098322514 098322515 1 21 Vestibule 055636309 055636309 055636309 055636309 1 22 Vestibule 055636304 055636305 055636306 055636307 1 N/S Turbulator 058387201 058387201 058387201 058387201 4

21

22

HeatExchanger

Burner 1

BurnerControl

Box 2

Gas Train 3

300

N/S= Not shown on diagram.1 Parts detail follows this section.2 Parts detail follows Burner section.3 Parts detail follows Burner Control Box section.4 Quantity varies depending upon the size of the Heat Exchanger. For 320/400 MBH order 6 pc.; for 500/640 MBH order 9 pc.; for

650/790 MBH order 12 pc.; for 800/1000 MBH order 15 pc. Note that Turbulators are NOT furnished with the Heat Exchanger Kit. Turbulators must be ordered separately.

Page 92: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 92

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner:Code 34= ****E*, ****R*, ****S*

Diagrams

109

113

149102115

147119

125

Burner Control Box

114 112124

116

117

105

145

110

142

143 130144

122

111

106

126120

127118

121

103104

107 108

123

160

161

Pilot Valve/ Pressure Regulator Assy Detail

200, 250, 320 MBH Burners

400- 1000 MBH Burners

160

162

Burner Control

Box

Page 93: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 93

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 102 Burner Housing 059362302 059362302 1 103 Scroll 035740701 035740701 1 104 Wheel- .5” bore 034861102 034861102 1 105 Motor- .25 HP, 115/60/1 034249200 034249200 1 106 Gun Assembly 200 MBH Furnace 034879901 034879901 1 250 MBH Furnace 034879902 034879902 1 320 MBH Furnace 034879903 034879903 1 400 MBH Furnace 034879904 034879904 1 500 MBH Furnace 034880001 034880001 1 640 MBH Furnace 034880002 034880002 1 650 MBH Furnace 034880002 034880002 1 790 MBH Furnace 034880003 034880003 1 800 MBH Furnace 034880003 034880003 1 1000 MBH Furnace 034880004 034880004 1 107 Inlet Funnel 034743101 034743101 1 108 Fan Guard 034742800 034742800 1 109 Blast Tube 200- 400 MBH Furnace 037378802 037378802 1 500- 650 MBH Furnace 034101703 034101703 1 790- 1000 MBH Furnace 034101707 034101707 1 110 Pilot Mixer 036516401 036516401 1 111 Pilot Assembly 035019600 035019600 1 112 Damper Assembly 035721501 048791401 1 113 Blast Tube Gasket 034102000 034102000 1 114 Right Side Damper 200- 500 MBH Furnace 058594301 058594301 1 640 MBH Furnace 058595201 058595201 1 650- 1000 MBH Furnace 058594501 058594501 1 115 Left Side Damper 200- 640 MBH Furnace 058595001 058595001 1 650- 1000 MBH Furnace 058594401 058594401 1 116 Slide Damper 200 MBH Furnace 058594801 058594811 1 250 MBH Furnace 058594802 058594812 1 320 MBH Furnace 058594803 058594813 1 400 MBH Furnace 058594804 058594814 1 500 MBH Furnace 058594805 058594815 1 640 MBH Furnace 058594806 058594816 1 650 MBH Furnace 058594807 058594817 1 790 MBH Furnace 058594808 058594818 1 800 MBH Furnace 058594809 058594819 1 1000 MBH Furnace 058594810 058594820 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner:Code 34= ****E*, ****R*, ****S*

Components

Page 94: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 94

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 117 Blower Gasket 035019500 035019500 1 118 Burner Cover 033972100 033972100 1 119 Ignition Assembly 1 1 1 120 Glass Cover 036557000 036557000 1 121 Glass Cover Support 036009600 036009600 1 122 Orifice 200 MBH Furnace 058599301 058599301 1 250 MBH Furnace 058599302 058599302 1 320 MBH Furnace 058599303 058599303 1 400 MBH Furnace 059861501 059861501 1 500 MBH Furnace 058599101 058599101 1 640 MBH Furnace 058599102 058599102 1 650 MBH Furnace 058599103 058599103 1 790 MBH Furnace 058599104 058599104 1 800 MBH Furnace 058599104 058599104 1 1000 MBH Furnace 058599201 058599201 1 123 Clip 034919400 034919400 1 124 Flange Bearing 034252000 034252000 2 125 Air Switch Tube 034102801 034102801 1 126 Pilot Burner Tube 200- 400 MBH Furnace 036236000 036236000 1 500- 1000 MBH Furnace 036236100 036236100 1 127 Compression Fitting 034097500 034097500 1 130 Pilot Tube 034102601 034102601 1 142 Manual Cock Valve- 200- 320 MBH only Not Used 034077300 1 143 Press. Reg. Valve- 200- 320 MBH only Not Used 034077600 1 144 90º Comp. Elbow- 200- 320 MBH only Not Used 034097200 1 145 Motor Conduit Box- 200- 320 MBH only 036558800 036558800 1 147 Torsion Spring Not Used 037528600 1 149 Burner Box Baffle 200- 400 MBH Furnace 058597901 058597901 1 500- 1000 MBH Furnace 058597902 058597902 1 160 Valve- Pressure Regulator 034077600 034077600 1 161 Valve- Manual: 200- 320 MBH 034077300 034077300 1 162 Valve- Solenoid: 400- 1000 MBH 034488400 034488400 1 N/S Flame Rod 036557700 036557700 1 N/S Ignition Electrode Assy. 300032902 300032902 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner:Code 34= ****E*, ****R*, ****S*

Components, Continued

N/S= Not shown on diagram.1 Contact Daikin Applied with model and serial number information so that the correct part can be identified.

Page 95: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 95

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner:Code 34= ****H*, ****T*, ****U*

Diagrams

119

328102

109

113

295

300

310318

358

110

106

121120

118

105

117

103

104 107108

358

114

297

322

321

323320

299

144

110

325

324

116

Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail

200- 400 MBH

324

500- 1000 MBH

375

145

Page 96: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 96

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 102 Burner Housing 059862103 059862103 1 103 Scroll 200- 800 MBH Furnace 096434806 096434806 1 1000 MBH Furnace 059862136 059862136 1 104 Wheel- .5” bore 200- 800 MBH Furnace 034861102 034861102 1 1000 MBH Furnace 034249005 034249005 1 105 Motor- .25 HP, 115/60/1 200- 800 MBH Furnace 034249200 034249200 1 1000 MBH Furnace 032248600 032248600 1 106 Gun Assembly 200 MBH Furnace 096414801 N/A 1 250 MBH Furnace 096414802 N/A 1 320 MBH Furnace 096414803 N/A 1 400 MBH Furnace 096414804 096414804 1 500 MBH Furnace 096414805 096414805 1 640 MBH Furnace 096414806 096414806 1 650 MBH Furnace 096414806 096414806 1 790 MBH Furnace 096414808 096414808 1 800 MBH Furnace 096414808 096414808 1 1000 MBH Furnace 096414810 096414810 1 107 Inlet Funnel 200- 800 MBH Furnace 034743101 034743101 1 1000 MBH Furnace 034743102 034743102 1 108 Fan Guard 034742800 034742800 1 109 Blast Tube 200- 400 MBH Furnace 037378802 037378802 1 500 MBH Furnace 034101703 034101703 1 640 MBH Furnace 034101703 034101707 1 650- 1000 MBH Furnace 034101707 034101707 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components

N/A= Not available.

Page 97: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 97

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 110 Orifice Assembly 200 MBH Furnace 096414701 N/A 1 250 MBH Furnace 096414702 N/A 1 320 MBH Furnace 096414703 N/A 1 400 MBH Furnace 096414704 096414724 1 500 MBH Furnace 096414705 096414725 1 640 MBH Furnace 096414706 096414726 1 650 MBH Furnace 096414707 096414727 1 790 & 800 MBH Furnace 096414708 096414728 1 1000 MBH Furnace 096414710 096414730 1 113 Gasket- Blast Tube 034102000 034102000 1 114 Air Box Assy 059862112 059862112 1 116 Plate- Actuator Scale 059645001 059645001 1 117 Gasket- Blower 035019500 035019500 1 118 Panel- Burner Box Cover 059388501 059388501 1 119 Ignition Wire Assy 1 1 1 120 Glass Cover- Burner 036557000 036557000 1 121 Support- Glass Cover 036009600 036009600 1 144 Grommet- Flat 060017701 060017701 1 145 Box- Conduit 036558800 036558800 1 295 Motor- Actuator 24V 113157801 113157801 1 297 Control Arm 059862114 059862114 1 299 Control Rod 059861101 059861101 1 300 Crank Arm 059645101 059645101 1 310 Extension- Crank Arm 059862110 059862110 1 318 Bushing- Control Rod 059861301 059861301 1 320 Linkage 096414901 096414901 1 321 Plate- Adjustable 200 MBH Furnace 096422001 N/A 1 250 MBH Furnace 096421601 N/A 1 320 MBH Furnace 059389601 N/A 1 400 MBH Furnace 096423001 096423101 1 500 MBH Furnace 060086401 096422901 1 640 MBH Furnace 096417701 096417801 1 650 MBH Furnace 096416301 096416301 1 790 MBH Furnace 060097101 060097101 1 800 MBH Furnace 060097101 096422701 1 1000 MBH Furnace 060092401 060097301 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components, Continued

N/A= Not available.1 Contact Daikin Applied with model and serial number information so that the correct part can be identified.

Page 98: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 98

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 322 Plate- Profile 200, 250 MBH Furnaces 096421501 N/A 1 320 MBH Furnace 059389001 N/A 1 400 MBH Furnace 060097601 060097601 1 500 MBH Furnace 060086101 060086101 1 640 MBH Furnace 096417901 096417901 1 650 MBH Furnace 096415301 096418001 1 790 MBH Furnace 096416501 096416501 1 800 MBH Furnace 060096901 060097001 1 1000 MBH 060092601 060097201 1 323 Plate- Slide Damper 200, 250, 320, 400 MBH Furnaces 059388801 059388801 1 500 MBH Furnace 060086301 060086301 1 640, 650 MBH Furnaces 096417601 096417601 1 790, 800, 1000 MBH Furnaces 060092501 060092501 1 324 Box- Air 200- 400 MBH Furnaces 059869101 059869101 1 500- 1000 MBH Furnaces 060092201 060092201 1 325 Gasket- Air Box 060092301 060092301 1 328 Grommet 000498100 000498100 1 358 Bearing- Sleeve 046761000 046761000 2 375 Grommet 500- 1000 MBH only 059988700 059988700 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components, Continued

Page 99: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 99

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Controls (Code 34= ****E*, ****R*, ****S*)MicroTech III Controls (Code 12= *E, *F, *W)

FSG Detail

24

34

2631

30

32

29Gas

ControlBox

61

63

27

Ref. Sch. Part Furnace MBH: Qty. No. Sym. Description 200, 250 320 400- 1000 11 GV1 Pressure Reg. Assy 061530300 061530300 039742000 1 Valve Only 034077600 034077600 034077600 1 Manual Cock Valve 034077300 034077300 Not Used 1 Solenoid Valve Not Used Not Used 034488400 1 24 Flame Safeguard Subbase 073300702 073300702 073300702 1 25 FSG Flame Safeguard 073300803 073300803 073300803 1 26 Amplifier 073300901 073300901 073300901 1 27 Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units 073301002 073301002 073301002 1 Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada 073301001 073301001 073301001 1 29 S3 Toggle Switch- 4PST 033536700 033536700 033536700 1 30 IT Ignition Transformer 034482600 034482600 034482600 1 31 AS Air Switch- Gas Burner 033003800 033003800 033003800 1 32 FLC Fan Limit Control 193423703 1 193423703 1 193423703 1 1 34 TB11 Terminal Block 349930641 349930641 349930641 18 Terminal Block End Stop 349930841 349930841 349930841 2 Terminal Block End Plate 349930741 349930741 349930741 1 Jumper Terminal 349930942 349930942 349930942 1 61 R20A Relay- High Amp DPDT/120V 349934764 349934764 349934764 1 62 R23A Relay- High Amp DPDT/120V 349934764 349934764 349934764 1 63 R23B Relay- Low Amp DPDT/120V 193424341 193424341 193424341 1

25 62

11

GV1 Detail

Panel Detail

FLC

S3

25FSG

IT

TB11

AS

R23B

R23A

R20A

1 Note that the sensor is NOT sold separately from the controller.

Page 100: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 100

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= AHi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U*

MicroTech III Controls (Code 12= *E, *F, *W)

FSG Detail

33

25

26

61

32

29

63

Ref. Sch. Part Part Qty. No. Sym. Description Number 24 Subbase- Flame Safeguard 073300702 1 25 FSG Control- Flame Safeguard 073300803 1 26 Amplifier 073300901 1 27 Time Delay- Flame Safeguard 073301002 1 29 S3 Switch- Toggle 033536700 1 30 IT Transformer- Ignition 034482600 1 31 AS Switch- Air 033003800 1 32 FLC Control- Fan Limit 193423703 1 1 33 LS1/LS2 Switch- Limit 059975301 2 34 TB11 Terminal 349930641 18 Terminal Block End Stop 349930841 2 Terminal Block End Plate 349930741 1 Terminal Block Jumper 349930942 1 61 R20A Relay-High Amp DPDT/120V 349934764 1 62 R20B Relay- Low Amp DPDT/120V 193424341 1 63 R21 Relay- Low Amp DPDT/120V 193424341 1

24

34

62

30

31

27

R21

R20A

TB11

R20B

LS1LS2

IT

FLC

S3

AS

LS1, 2

FSG

1 Note that the sensor is NOT sold separately from the controller.

Page 101: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 101

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner: Code 34= ****E*, ****R*, ****S*Gas Train- Inlet

234

Units without Pressure Regulator Valve Code 34= ****E*

Units with Pressure Regulator Valve Code 34= ****R*, ****S*

228

234

228234

228

234200, 250, 320

MBH Furnaces400, 500, 640, 650, 800

MBH Furnaces 1000 MBH Furnaces

205205

205

Ref. Part Part Qty. No. Description Number 205 Shutoff Valve 400 - 1000 MBH 034077300 1 234 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1

Ref. Part Pressure Regulator Qty. No. Description 2- 3 PSI 5- 10 PSI 205 Shutoff Valve 400 - 1000 MBH 034077300 034077300 1 228 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 036619923 1 234 Gas Valve 200, 250, 320 MBH 073387401 073387401 1 400, 500 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1

400- 1000 MBH

234

200- 320 MBH

Gas Flow

Gas Flow

Page 102: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 102

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*

Gas Train- InletCanada Units— Code 07= CC, CD

226

Units without Pressure Regulator ValveCode 34= ****H*

Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1 292 Combination Valve 073336504 1

Units with Pressure Regulator Valve Code 34= ****T*, ****U*

226

232

200- 320 MBH 400- 1000 MBH

226

232

Ref. Part Pressure Regulator Qty. No. Description 2- 3 PSI 5- 10 PSI 226 Shutoff Valve 200, 250, 320 MBH 073387401 073387401 1 400, 500 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1 232 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 036619923 1 292 Valve- Combination 073336504 073336504 1

Combination Valve Detail

292

Back Wall of Vestibule

Combination Valve Detail

292

Back Wall of Vestibule

Gas Flow

Page 103: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 103

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*

Gas Train- InletUL Units— Code 07= EU, YU

226

Units without Pressure Regulator ValveCode 34= ****H*

Units with Pressure Regulator Valve Code 34= ****T*, ****U*

226

232

Ref. Part Pressure Regulator Qty. No. Description 2- 3 PSI 5- 10 PSI 226 Shutoff Valve 200, 250, 320 MBH 073387401 073387401 1 400, 500 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1 232 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 073387403 1

Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1

Page 104: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 104

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner: Code 34= ****E*, ****R*, ****S*

Gas Train- Controls: GV2, GV3UL Units— Code 07= EU, YU

255

261

256

248

255261

256

248 248

253

GV2

GV2 GV3

400- 1000 MBH Furnaces

UL Approved (Code 07= EU, YU)

200- 320 MBH Furnaces Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2 073336502 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 261 Gas Pipe 200, 250 MBH 055963904 1 320 MBH 055963903 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2, GV3 400, 500 MBH 073387801 2 640- 1000 MBH 073387802 2 253 Pressure Regulator 400, 500 MBH 034078100 1 640- 1000 MBH 034077804 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 261 Gas Pipe 400, 500 MBH 055964001 1 640 MBH 055964101 1 650, 790 MBH 055964106 1 800, 1000 MBH 055964103 1

Gas Controls: 400- 1000 MBH FurnaceUL Approved

Page 105: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 105

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner: Code 34= ****E*, ****R*, ****S*

Gas Train- Controls: GV2, VM1Canada Units— Code 07= CC, CD

255

400- 1000 MBH Furnaces

Canada Approved (Code 07= CC, CD)

261

256

248

GV2

GV2

261249

248

253

200- 320 MBH Furnaces Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2 073336502 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 261 Gas Pipe 200, 250 MBH 055963904 1 320 MBH 055963903 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 248 Gas Valve Body- GV2 400, 500 MBH 041768902 1 640 - 1000 MBH 041768903 1 249 Actuator- VM1 113157801 1 253 Pressure Regulator 400, 500 MBH 034078100 1 640- 1000 MBH 034077804 1 261 Gas Pipe 400, 500 MBH 055964201 1 640, 650 MBH 055964301 790 MBH 055964305 1 800, 1000 MBH 056011102 1

Gas Controls: 400- 1000 MBH FurnaceCanada Approved

Page 106: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 106

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*

Gas Train- Controls: GV1, GV2, GV4, GV5, GV6

790- 1000 MBH Furnaces

Canada Approved (Code 07= CC, CD)

254

254

GV2

400- 650 MBH Furnaces

UL Approved (Code 07= EU, YU)

200- 320 MBH Furnaces

Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV2 073336504 1 N/S Junction Box 020766100 1 N/S Junction Box Cover 000127300 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV1, GV4 400- 650 MBH 073336504 2 Gas Valve- GV1,GV4,GV5 790- 1000 MBH 073336504 3

Gas Controls: 400- 1000 MBH FurnaceUL Approved

Ref. Part Part Qty. No. Description Number 246 Gas Valve Body- GV2 400, 500 MBH 041768902 1 640- 1000 MBH 041768903 1 247 Actuator- GV2 111047401 1 254 Gas Valve- GV4, GV5 400- 650 MBH 073336504 2 Gas Valve- GV4,GV5,GV6 790- 1000 MBH 073336504 3

Gas Controls: 400- 1000 MBH FurnaceCanada Approved

N/S= Not shown on diagram.

GV4

GV1254

GV4GV1

GV5

790- 1000 MBH Furnaces

UL Approved (Code 07= EU, YU)

400- 650 MBH Furnaces

Canada Approved (Code 07= CC, CD)

GV5

GV4

GV2247

246

254

254

246

254

GV5 GV4

GV6

GV2247

254254

Page 107: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 107

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Gas Train- Outlet

275

283

400- 1000 MBH277

283200- 320 MBH

Ref. Part Part Qty. No. Description Number 275 Pipe w/ Valve Mount 200- 320 MBH 035019700 1 400 MBH 046674500 1 500 MBH 035019800 1 640- 1000 MBH 036235500 1 277 Butterfly Valve 200- 320 MBH 034488302 1 400, 500 MBH 034488303 1 640- 1000 MBH 034488304 1 283 Shutoff Valve 200- 320 MBH 059468801 1 400, 500 MBH 059468802 1 640- 800 MBH 059468803 1 1000 MBH Canada 058968804 1 1000 MBH UL 059468803 1

Actuator & Linkage-

See next page

275

275

Hi Turn Down BurnersCode 34= ****H*, ****T*, ****U*

Modulating BurnersCode 34= ****E*, ****R*, ****S*

200- 500 MBH

640- 1000 MBH

Actuator & Linkage- See next page

275 277

Ref. Part Part Qty. No. Description Number 275 Gas Valve 200- 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 800 MBH 910144817 1

Page 108: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 108

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Gas Train- Damper LinkageModulating Burners w/ VM1 Actuator

Code 34= ****E*, ****R*, ****S*

297

Burner Box

295

311

298

300

310

299

Butterfly Valve (see previous page)

USA Units/Canada Units (200- 320 MBH)

Canada Units (400- 1000 MBH)

297

Burner Box

295

311

298

300

310

299

Butterfly Valve (see previous page)

301

Canada Actuator Detail

VM1Actuator

Switch KitTransformer

Ref. Part Furnace MBH Qty. No. Description 200- 320 400 500- 650 790- 1000 295 Actuator Motor- VM1 Units w/ MicroTech III Controls USA Units 113157801 113157801 113157801 113157801 1 Canada Units 113157801 091688002 1 091688002 1 091688002 1 1 297 Crank Arm 034250600 034250600 034250600 034250600 1 298 Ball Joint 034250500 034250500 034250500 034250500 2 299 Linkage Arm 058598401 058598401 058598401 058598401 1 300 Crank Arm 023463200 023463200 023463200 023463200 1 301 Extension Arm (Canada Units Only) Not Used 098735201 098735201 098735201 1 310 Air Damper Lever Arm 058598101 058598101 059365001 058598101 1 311 Gas Valve Arm 058598601 058598601 058598601 058598601 11 Assembly part number. Motor only is p/n 113157801, and Switch Kit only is p/n 060009101.

Page 109: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 109

Section G- BlowThru Heat SectionOption 4- Gas Heat w/ 200 MBH and 250 MBH Furnace

Code 04= A AND Code 34= 020***, 025***Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting

051

664665

052

664

665

658

668

667

661

668 667

668

668

Ref. Part Part Qty. No. Description Number 051 Door Assembly 098347015 1 052 Door Assembly 098347020 1 658 Back- Flue Box 403398101 1 661 Flue Box Mount 403399301 1 664 Sleeve Bearing 047138507 6 665 Door Catch 055502602 6 667 Gasket 055921409 4 668 Gasket 055921410 4

Page 110: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 110

Section G- BlowThru Heat SectionOption 4- Gas Heat w/ 320 wMBH thru 1000 MBH Furnace

Code 04= A AND Code 34= 032***,040***,050***,064***,065***,079***,080***, 100***Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting

Ref. Part Part Qty. No. Description Number 650 Door Assembly 320, 400 MBH 098347021 1 500, 640 MBH 098347022 1 650, 790 MBH 098347023 1 800, 1000 MBH 098347024 1 652 Inspection Door 034095801 1 658 Back- Flue Box 320, 400 MBH 403398001 1 500, 640 MBH 403398401 1 650, 790 MBH 403398601 1 800, 1000 MBH 403398801 1 661 Angle- Flue Box 320, 400 MBH 403399401 1 500, 640 MBH 403399501 1 650, 790 MBH 403399601 1 800, 1000 MBH 403399701 1 663 Drip Shield 033487300 1 664 Sleeve Bearing 047138507 3 665 Door Catch 055502602 3 667 Gasket 055921409 2 668 Gasket 055921410 2 669 Gasket 031949200 1 673 Hinge 034005900 2

650

664665 667

661

658

668669

663

652

Page 111: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 111

Section H- BlowThru Heat Blank Access SectionNotes AND Access Door Latching Assemblies, Key, & Lock

Primary Codes that pertain: 38, 34Additional Codes that pertain: 06

Code 38 determines the section’s characteristics. If Code 38= Y, there is no section. If Code 38= F there is a 48” BlowThru Blank/Empty section. If Code 38= E there is a 24” Blank/Empty section. If Code 38= G, H, there is a Straight Attenuator. If Code 38= K, L there is a Straight Attenuator with Tedlar coating. If Code 38= J there is an Elbow Attenuator. If Code 38= M there is an Elbow Attenuator with Tedlar coating.

Code 34 determines the BlowThru Heat Section (Section G). There has to be a Section G in order for there to be a Section H, therefore Code 34 CANNOT= YYYYYY.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heat Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered.

Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing 047138507 6 N/S Door Catch 055502602 6 N/S Gasket- Horizontal 055921408 1 4 N/S Gasket- Vertical 055921410 4

Door Hardware and Gasketing

N/S= Not Shown on diagram.1 If the unit is split at the fan and heat sections (Code 05= F) use p/n 055921409.

Access Door Latching Assemblies, Key, & Lock (All Sections) 2

Door Latching Assy.Left Hand

Door Latching Assy.Right Hand

01 02

Ref. Part Part Qty. No. Description Number 01 Door Latching Assy.- LH, 73" Section 111242211 var. 02 Door Latching Assy.- RH, 73" Section 111242212 var. 01 Door Latching Assy.- LH, 97” Section 111242221 var. 02 Door Latching Assy.- RH, 97” Section 111242222 var. N/S Access Door Key 021993200 var. N/S Access Door Lock 112031701 var.N/S= Not Shown on diagram.2 These Door Latching Assemblies are used on Standard Unit Section Access Doors.

When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Once the door handing is determined, it is then necessary to determine the height of the section. The 73" Latching Assembly is used for unit sections 73 inches high (most sections) and the 97" assembly is used for 97" high sections (eg. Section A2 Energy Recovery [Code 20= *E]).

Page 112: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 112

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT16 065492402 1 88 Light Switch- S16 065492201 1 89 Receptacle- REC16 030187000 1

LT16- BT Cooling Section Light/S16- BT Cooling Section Light Switch/REC16-BT Cooling Section Receptacle.84 85

88 89

Section Mounted ControlsLT16, S16, REC16

Section I- BlowThru Cooling SectionNotes

Primary Codes that pertain: 03, 35, 36Additional Codes that pertain: 06

Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil, and if Code 03= L there is a large face area Coil.

Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 48” section. If the first three digits of Code 35= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T, the first three digits of Code 35 must be DYY.

Code 36 determines the Cooling Coil characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

NOTE: See Section D for all parts used in Section I. Although the section location is different within the unit configuration, the components are identical.

Page 113: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 113

Section J- Final Filter SectionNotes

Primary Codes that pertain: 39Additional Codes that pertain: 04, 34, 33

Code 39 determines all of the section characteristics. If Code 39= A, J, B, K, E, L, F, M, G, N, H there are filters; if Code 39= Q, R, S, T then there is a Blank/Empty section. If Code 39= Y, there is no section.

Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts.

Code 33 indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description.

Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing 047138507 6 N/S Door Catch 055502602 6 N/S Gasket- Horizontal 055921408 1 4 N/S Gasket- Vertical 055921410 2

Door Hardware and Gasketing

N/S= Not Shown on diagram.1 If the unit is split at the fan and heat sections (Code 05= F) use p/n 055921409.

387

386

Unit AirFlow

Ref. Part Part Qty. No. Description Number 386 Stat Support 058379401 1 387 HL23 Firestat 047938804 1

Control HL23 Gas Heat Hi-Limit (Firestat)

Gas Hi Limit Control Clogged Filter Control

Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl. 065493801 1

UnitBase

345

Supplied with PC6 Harness from Main/Split Box

Section Mounted ControlsHL23 Gas Hi Limit Control: Code 04= A AND Code 39 DOES NOT= Y

PC6 Clogged Filter Control: Code 39 DOES NOT= Y, R, S, T

Page 114: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 114

Section J- Final Filter SectionFilters

Flat Filter Rack- Code 39= A, E, J, G, N

Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 24 x 24 x 12” High Heat A, E A, J 073381102 8 Filter- 95% Eff- Cartridge, 24 x 24 x 12” Standard S, W A, J 065810702 8 Filter- 95% Eff- Cartridge w/ Intersept, 24 x 24 x 12” ALL ALL E, L 1 8 Filter- 95% Eff- HEPA Cartridge, 24 x 24 x 12” ALL ALL G, N 1 8 4A Gasket- Filter High Heat A, E ALL 073337024 8 Gasket- Filter Standard S, W ALL 021768924 8 5 Filter- 95% Eff- Cartridge, 12 x 24 x 12” High Heat A, E A, J 073381101 4 Filter- 95% Eff- Cartridge, 12 x 24 x 12” Standard S, W A, J 065810701 4 Filter- 95% Eff- Cartridge w/ Intersept, 12 x 24 x 12” ALL ALL E, L 1 4 Filter- 95% Eff- HEPA Cartridge, 12 x 24 x 12” ALL ALL G, N 1 4 5A Gasket- Filter High Heat A, E ALL 073337012 4 Gasket- Filter Standard S, W ALL 021768912 4

4

5

4A

5A

1 Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified.

Page 115: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 115

Staggered Filter Rack- Code 39= B, F, K, M

14 14A

14 14A

Section J- Final Filter SectionFilters, Continued

Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 14 Filter- 95% Eff- Cartridge, 24 x 24 x 12” High Heat A, E B, K 073381102 8 Filter- 95% Eff- Cartridge, 24 x 24 x 12” Standard S, W B, K 065810702 8 Filter- 95% Eff- Cartridge w/ Intersept, 24 x 24 x 12” ALL ALL F, M 1 8 14A Gasket- Filter High Heat A, E B, K 073337024 8 Gasket- Filter Standard S, W B 021768924 8 15 Filter- 95% Eff- Cartridge, 12 x 24 x 12” High Heat A, E B, K 073381101 8 Filter- 95% Eff- Cartridge, 12 x 24 x 12” Standard S, W B, K 065810701 8 Filter- 95% Eff- Cartridge w/ Intersept, 12 x 24 x 12” ALL ALL F, M 1 8 15A Gasket- Filter High Heat A, E B, K 073337012 8 Gasket- Filter Standard S, W B, K 021768912 81 Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified.

15 15A

Page 116: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 116

Section K- Discharge Plenum Section- RPSNotes

Primary Codes that pertain: 40Additional Codes that pertain: 6, 11, 16, 34, 35, 36, 38, 39, 41.

Code 40 determines the discharge direction. RPS units may have bottom discharge (Code BE, BY) OR side discharge (Code LY, RY, SY). VAV damper option is Code *E.

Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

Code 11, Disconnect Switch option, influences Access Door part numbers.

Code 16 determines Smoke Detectors. If Code 16= 2, 3 there is a Supply Air Smoke Detector (SD1). For RPS units with heat the SD1 is in Section K. For RDT units, OR RPS draw thru cooling only units (units with no separate discharge plenum section) SD1 is in the Supply Air section (Section F).

Codes 34- 39, the BlowThru/Final Filter section codes, and Code 41, the special Blank/Empty section code, pertain to some of the final assembly part numbers. If there is no BlowThru final section then the Discharge Plenum is attached directly to the Supply Air Section and some of the final assembly part numbers are different than they are if the BlowThru section is present. If Code 41= Y (no Blank Access Compartment), then the Discharge Plenum end panels are painted. If the Blank/Empty section is present then the end panels are unpainted.

Note: The RPS Main Control Box is located in the Discharge Plenum Section. However, Main Control Box components are listed in Section N.

50

51

Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD1 098873101 1 51 Sensing Tube 049025002 1

Smoke Detector- SD1

Section Mounted ControlsOAT, DAT, SD1

Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor- OAT 193414602 1 8 DA Temp. Sensor- DAT 193414602 1

Discharge Air Temperature Sensor- DAT &Outdoor Air Temperature Sensor- OAT7 8

OAT DAT

Smoke Detector

Detail

Page 117: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 117

Section K- Discharge Plenum SectionDischarge Damper Assembly- w/ Actuator ACT5

Code 40= BE

ACT5 Actuator Linkage Detail

15

23

20

3

1917

26

424

16

1821

2215

22

Ref. Part Part Number Qty. No. Description C40= BE Complete Damper Assy. w/ Actuator 403716304 1 3 Motor Mount 055921201 1 4 Blade 055921302 9 15 Angle- Linkage 055917702 3 16 Blade- Angle 055638102 27 17 Shaft- Damper 055637801 18 18 Linkage- Shaft 055536601 1 19 Bearing, Flange- Damper 001113500 18 20 Actuator, 24V ACT5 113144901 1 21 Crank Arm 403717101 1 22 Ball Joint 000887000 2 23 Bearing- Sleeve 047138507 27 24 Gasket 030051985 10 25 Support- Actuator 403716801 1 26 Retainer- Actuator 403717301 1 27 Bearing- Sleeve 047138504 1

NOTE: This Discharge Damper and ACT5 Actuator assembly may also be located in Section F (Supply Air). The Discharge Air opening is in the Supply Air section on RDT units, and RPS DrawThru units with no BlowThru heat (applications where Section F is attached directly to the condensing unit, OR is the end of the unit).

27

25

21

20

Page 118: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 118

Section L- Out-of-Airstream Blank Access SectionNotes

Primary Codes that pertain: 41

If Code 41= Y, there is no Blank/Empty section. If Code 41= 1, there is a 48/24” Blank/Empty section with Access Doors and Light (LT20). When Code 41= 2, there is a 48” Blank/Empty section with Access Doors and Light (LT20).

For sheet metal components that make up the Out-of-Airstream Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard access Door Latching Assemblies, see Section H.

The blank access section may be installed on an RPS unit.

Ref. Part Section Size No. Description 48” (C41= 1) Qty. 48/24” (C41= 2) Qty. N/S Door Assembly 060056005 2 060056005 2 060056002 2 N/S Gasket- Horizontal 055921409 4 055921409 4 055921408 4 N/S Gasket- Vertical 055921410 4 055921410 8 N/S Door Sleeve Bearing 047138507 6 047138507 12 N/S Door Catch 055502602 6 055502602 12

Doors, Gasketing and Hardware

N/S= Not Shown on diagram.

Ref. Part Part Qty. No. Description Number 284 Light Fixture 042229500 1 285 Bulb- LT20 065492402 1 288 Light Switch- S20 065492201 1 289 Receptacle- REC20 030187000 1

LT20- Blank Access Section Light/S20- Blank Access Section Light Switch/REC20- Blank Access Section Receptacle284 285

288 289

Section Mounted ControlsLT20, REC20, S20- Section Mounted Light

Page 119: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 119

Section M- Condenser SectionNotes

Primary Codes that pertain: 09, 23, 43, 44, 45, 47

This section houses the Compressors, Condenser Coils, Pressure Controls Box, and Fan Deck.

The Compressor high and low pressure controls as well as the fan pressure controls are always located in this section as well as SpeedTrol Inverters and Line Reactors (if supplied) in a box mounted where the air handler and condensing unit attach.

Code 09, unit voltage, affects Compressor Contactors and Motor Protectors as well as the Compressor selection.

Code 43 determines if the Micro Channel Condenser Coils have Seal Tite Conduits and/or Coil Guards; and whether the Coils are Electrofin coated.

Code 44 shows the type of compressor selected. For this form Code 44 always = V, W for units with Inverter Compressors. For standard OR Digital Scroll Compressor units (Code 44= R, D) refer to form 7000137. Note that RPS, RDT074Ds are inverter compressor only units.

Code 45 determines the way the compressor is mounted.

Code 47 determines Condenser Fan operation. Note that ALL inverter compressor units have SpeedTrol (Low Ambient operation [Code 47= 2, L]) as standard. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol.

Page 120: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 120

Section M- Condenser SectionCondenser Fan Deck Assembly

Diagrams: Code 47= 2

(063D shown)

05

045D, 050D Fan Deck Detail

112

113

101

113

130

132

131

111

Motor Mount to Fan Panel Mounting Detail

Fan Detail

150 55

CDF150

CDF160

CDF153

MO

TOR

GN

DW

IRE

CDF151

Fan # 12Fan # 11

Fan # 22Fan # 21

End of Unit

074D Fan Deck Detail

Fan # 24

Fan # 11

Fan # 21

Fan # 14

Fan # 13

Fan # 23

Fan # 15

Fan # 12

Fan # 22

End of Unit

101

125

113

131

121

133

133

Fan Layout Detail

051D Fan Deck Detail

Fan # 12Fan # 11

Fan # 22Fan # 21

End of Unit

063D Fan Deck DetailFan # 12 Fan # 11

Fan # 22 Fan # 21Fan # 23

Fan # 13

End of UnitEnd of Unit

Page 121: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 121

Ref. Part Part Unit Size No. Description Number 045 050 051 063 074 Condenser Coils Code 43= M* 05 33.5” x 71” 910137801 4 4 36” x 84” 910137884 2 2 2 46" x 84" 910137886 2 2 2 Condenser Coils Code 43= T* 05 33.5” x 71” 910152744 4 4 36” x 84” 910152750 2 2 2 46” x 84” 910152752 2 2 2 Condenser Coils, Coated Code 43= P* 05 33.5” x 71” 910137802 4 4 36” x 84” 910137885 2 2 2 46” x 84” 910137887 2 2 2 Condenser Coils, Coated Code 43= U* 05 33.5” x 71” 910152745 4 4 36” x 84” 910152751 2 2 2 46” x 84” 910152753 2 2 2 Condenser Fan Code 47= 2 55 Panel- Blank 2 258933501 2 2 5 3 101 Top Panel 258929501 4 4 4 6 9 111 Motor- Condenser, 208- 460V 500552601 4 4 4 6 9 Motor- Condenser, 575V 046744203 4 4 4 6 9 112 Fan Propeller 258981901 4 4 4 6 9 113 Motor Mount 1 098667802 8 8 8 12 18 121 Grommet 000898500 16 16 16 24 32 125 Spacer- Steel 030434500 16 16 16 24 32 130 Screw- Cap 048878129 16 16 16 24 32 131 Nut- Lock 040500104 32 32 32 48 64 132 Washer, Narrow- Plain 040500307 16 16 16 24 32 133 Washer, Wide- Plain 041542301 32 32 32 48 64 150 Fan Guard 098668302 4 4 4 6 9

Section M- Condenser SectionCondenser Fan Deck Assembly

Components: Code 47= 2

1 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of two per Motor.2 Note that the same p/n and quantity is also used for Quiet Fan Assemblies (Code 47= 4).

Page 122: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 122

Section M- Condenser SectionQuiet Fan Assembly

Code 47= 4

11

Unit Size Ref. Part Part No. Description Number 045 050 051 063 074 1 Quiet Fan Assy. 1, 2

208V 500526602 4 4 4 6 9 230V 500526603 4 4 4 6 9 460V 500526604 4 4 4 6 9 575V 500526605 4 4 4 6 91 Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including

the Motor, Fan Prop, Fan Guard, Motor Mount, and Fan Top Panel are NOT avail-able separately.

2 For Top Panel Blank Panels Bub # 55) see the previous page.

Page 123: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 123

3 1

Section M- Condenser SectionCompressors Circuit #1: Code 44= V, W

Unit Size 045 050 051 063 074

Ref. Part No. Number Compressors 1, 3, 5 500597501 1 2 500597502 1 2 500597504 1 2 300046089 1 2 300046091 1 2 300046093 1 2 300046089 1 2 300046091 1 2 300046089 1 2 404152401 1 2 404152402 1 2 404152404 1 2 404152401 1 3 404152402 1 3 404152404 1 3 N/S Crankcase Heater 112056402 2 2 2 112056401 2 2 2 2 2 2 113108903 2 2 2 3 3 3 Misc. Components N/S Rotolock Connector 910153986 2 2 2 N/S Teflon Seal 330503006 2 2 2

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

N/S= Not shown on diagram.1 Note that even though these compressors are factory installed as assemblies, replacement compressors are

sold as SINGLE compressors only.

045D thru 063D Tandem shown

Page 124: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 124

Section M- Condenser Section Compressors Circuit #2: Code 44= V, W

Unit Size 045 050 051 063 074

Ref. Part No. Number Compressors 2 910141914 1 910141913 1 910175887 1 910141914 1 910141913 1 910175887 1 910141914 1 910141913 1 910175887 1 910141914 1 910141913 1 910175887 1 910141914 1 910141913 1 910175887 1 2A Sightglass, Compressor 300046260 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2B Gasket, Sightglass 300056705 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Crankcase Heater 910150288 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

N/S= Not shown on diagram.1 Refer to the following page.

Optical Oil Sensor location 1

Oil Injection Solenoid location 1

Compressor Sightglass & Gasket

2A

2B

Page 125: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 125

Section M- Condenser Section Inverter Compressor Components

Discharge Temp. Sensor

127

Optical Oil Sensor

126

Oil Injection Solenoid

125

128

132

126A

Ref. Part Part Qty. No. Description Number 125 Solenoid, Oil Injection, 24V 910150289 1 126 Oil Sensor, Optical 910150291 1 126A Sight Glass/Prism, Optical Oil Sensor 1 910165172 1 127 Sensor, Compressor Discharge Temperature 910150290 1 128 Connector, Rectangular 910153164 1 132 Fitting, Male 910153162 11 The Sight Glass/Prism comes assembled with Optical Oil Sensor p/n 910150291 (Ref # 126). If ONLY the

Sight Glass/Prism is required use p/n 910165172.

Page 126: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 126

Section M- Condenser SectionCompressor Mounting Components

Compressor Mounting Circuit #1

Ref. Unit Size Part Part Qty. No. Description Number 102 045, 063 Grommet 251774401 6 050, 051 Mounting Kit 300000462 2 074 Grommet 251774401 8 103 045, 063 Sleeve 111056201 6 074 Sleeve 111056201 8 105 045, 063 Screw 046093822 6 074 Screw 046093822 8 106 045, 063 Washer 040500316 6 074 Washer 040500316 8 107 045, 063 Washer, Locking 048164812 6 074 Washer, Locking 048164812 8

Compressor Mounting Circuit #2

Ref. Unit Size Part Part Qty. No. Description Number 102 ALL Mounting Kit 910152997 1

102

103

106

105 107

102

Unit Size 045, 063, 074 Unit Size 050, 051

102

Page 127: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 127

Ref. Part Part Unit Size No. Description Number 045 050 051 063 074 Coil Guards (Code 43= *G, B) 101 Side Grille 403805601 1 1 1 102 End Grille 403794800 1 1 End Grille 403801400 1 1 1 105 End Filler Panel 403821301 1 1 1 End Filler Panel 403822901 1 1 106 Side Grille, Pressure Controls 403821400 1 1 1 Side Grille, Pressure Controls 403823000 1 1 107 Pressure Control Box Filler Panel 403823701 1 1 108 Side Grille, VFD 910166795 1 1 1 Side Grille, VFD 910167599 1 1

Section M- Condenser SectionCondenser Coil Guards: Code 43= *G, B

105

102

101

107

106

101

108

Page 128: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 128

SPTRL

SPTRL

PT1

PT2

LP

LP

HP

HP

Ref. Sch. Part Part Qty. No. Sym. Description Number 220 TB35 Terminal Block Assy. 208- 460V 910150442 1 221 TB36 Terminal Block Assy. 208- 460V 404148501 1 N/S TB37 Terminal Block Assy. 575V 910181036 1 233, 234 LP1, 2 Switch- Low Pressure 910139364 2 235 HP1, 2 Switch- High Pressure 403585001 2 237 SPTRL Switch- SpeedTrol Pressure 403586901 2 237A - Harness, Pressure Transducer 403586601 2 238 - Valve Core 026541100 10 239 - Valve Cap 032943500 6 241 PT1, 2 Pressure Transducer 910153045 2 243, 244 VFD11, 21 SpeedTrol Inverter- Size 045, 050, 051D 208/230V, 3HP 193475807 1 2 460V, 3HP 193475823 1 2 575V, 3HP 193456303 1 2 243, 244 VFD11, 21 SpeedTrol Inverter- Size 063D 208/230V, 4 HP 193475808 1 2 460V, 4 HP 193475824 1 2 575V, 4 HP 193456304 1 2 270 LR11B, 21B Line Reactor- SpeedTrol (575V) 073323552 2

239

237

235

244

241

237

234

243

238

239238

238

238

238

238

233

238

241 238

235

Section M- Condenser SectionPressure Controls Box 045D thru 063D

237A

237A

221

270

220

N/S= Not shown on diagram.1 For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Page 129: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 129

PT2

PT1

SPTRL

SPTRL

HP

HP

LP

LP

Section M- Condenser SectionPressure Controls Box- 073D

235

244

241

237

234

243

239238

238

238

238

233

238

241 238

235

221

270

220

Ref. Sch. Part Part Qty. No. Sym. Description Number 220 TB35 Terminal Block Assy. 208- 460V 910150442 1 221 TB36 Terminal Block Assy. 208- 460V 404148501 1 N/S TB37 Terminal Block Assy. 575V 910181036 1 233, 234 LP1, 2 Switch- Low Pressure 910139364 2 235 HP1, 2 Switch- High Pressure 403585001 2 237 SPTRL Switch- SpeedTrol Pressure 403586901 2 238 - Valve Core 026541100 10 239 - Valve Cap 032943500 4 240 - Harness, Pressure Transducer 403586601 2 241 PT1, 2 Pressure Transducer 910153045 2 243 VFD11 Inverter- SpeedTrol, 7.5HP 208/230V 193475810 1 2 460V 193475826 1 2 575V 193456305 1 2 244 VFD21 Inverter- SpeedTrol, 5.0 HP 208/230V 193475809 1 2 460V 193475825 1 2 575V 193456304 1 2 270 LR11B, 21B Line Reactor- SpeedTrol (575V) 073323552 2

240

240237 238

239238

N/S= Not shown on diagram.1 For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Page 130: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 130

PB11

REC1

F11 F22 PVM1

F1C

F1B

F1C

Section M- Condenser SectionFactory Supplied Powered Receptacle- Code 23= ***F*

DS6, TB7, T6, FU6A, B, C

Voltage Ref. Sch. Part Part No. Sym. Description Number 01 DS6 Fuse Holder/Circuit Protector 2P, 30A, 600V 193443801 1 1 1 1 02 FU6A, B Fuse 20A/600V 300042980 2 2 Fuse 10A/600V 049759816 2 Fuse 8A/600V 049759814 2 03 TB7 Terminal, 2 x 2 Green 349930647 1 1 1 1 04 Terminal Block End Plate 349930741 1 1 1 1 05 Terminal, 2 x 2 Grey 349930641 2 2 2 2 06 Terminal Block End Stop Grey 349930841 2 2 2 2 247 T6 Transformer 2KVA 099477214 1 Transformer 2KVA 099477114 1 1 Transformer 2KVA 099477314 1 248 - Terminal Cover Kit 099477601 1 1 1 1 249 FU6C Fuse 20A/600V 042753123 1 1 1 1

208V

230V

460V

575V

Pressure Controls Box(073D shown)

247

Main Control Box

02

01 248

249

0304

0605

Page 131: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 131

Section M- Condenser SectionInverter Compressor Control Box

Ref. Sch. Part Part Qty. No. Sym. Description Number 020 TB14 Terminal Block Assy. 1 910150441 1 02 End Stop 349930841 2 2 03 Terminals 349930641 2 16 04 Socket, Relay 074805901 2 3 05 R38, 39 Relay, 120V 349934724 2 2 06 R40 Relay, 24V 330278110 2 1 07 End Plate 349930741 2 1 050 Heater, 120V 910154595 2 060 Tstat, Heater 910154391 1 330 VFD/AFD2 Inverter, Compressor 4 208/230V 910146943 1 460V 910146944 1 575V 3 1 329 Local Control Panel, Inverter 4 910150298 1 331 Muffin Fan 910147046 2 334 Louver Kit 113142701 1 335 Filter Kit 113143601 1 336 Cylinder Lock 112031701 11 The Terminal Block Assembly includes End Stops, Terminals, Relays, Relay Sockets, and an End Plate. Refer to the detail drawing

to identify individual parts of this assembly.2 Part ONLY of Terminal Block Assembly p/n 910150441.3 Contact Daikin Applied with model and serial number information so that the correct inverter can be identified.4 Note that the Local Control Panel (Ref # 329) is NOT supplied with the inverter. It must be ordered SEPARATELY if needed.

06 330

05

03 050

331

02

331020

060

04

02 07

334

335

336045D, 050D, 051 shown

TB14 Detail

329

Local Control Panel 4

Page 132: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 132

Section N- Main Control BoxNotes

Primary Codes that pertain: 08, 09, 11, 12, 13, 14, 15, 16, 17, 18, 23Additional Codes that pertain: 04, 19, 20, 22, 27, 30, 32, 34, 35, 40

The Main Control Box is comprised of three primary parts— The Deadfront Door with the Keypad, the Control Panel, and the Power Panel.

Code 08 determines where the Control Box is installed- “D” indicates the Discharge Plenum (RPS), “F” indicates the Supply Air Section (RDT).

Code 9 is the unit voltage and affects the Transformers, Fan Overloads/MMPs, Contactors, Fuses, etc.

Code 11 determines whether the main power connection is a Power/Terminal Block OR a through-the-door Disconnect.

Code 12 determines which type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, OR none) and whether the unit uses Discharge Temperature, Space Control, OR Zone control. There is an MCB and separate Expansion Boards (Condenser, Electric Heat, Energy Recovery) in the Control Box.

Code 13 determines the presence of Duct and/or Space Sensors.

Codes 14 and 15 determine the Supply and Return Fan Inverter characteristics.

Code 16 determines the presence of Smoke Detectors.

Code 17 AND/OR 23 determine miscellaneous electrical options including whether the unit has a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc.

Code 18 indicates whether a unit has a Remote Keypad Display and/or a unit mounted Receptacle.

Codes 19, 20 and 22 are return air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc, have an impact on Contactors, Motor Protectors, Fuses, and Duct Sensors.

Code 27 determines the draw through section, and can impact the Cooling Circuit Relays.

Code 32 determines horsepower for the Supply Fan Motor which, like the Return Air Motor, will affect Contactors, Motor Protectors, Fuses, Overloads, etc.

Codes 04, 30, (RDT) 34, and 35 determine the BlowThru section, and the heat type, which will impact the Transformers, heat circuit Relays, and cooling circuit Relays.

Code 40 determines if there is a VAV/Discharge Damper and associated Relay.

Page 133: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 133

Section N- Main Control BoxControl Box Component Label Diagram 1

1 This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected.

GOI Number: H023450700800R02

MB= Main Box; BB= Bypass Box; EB= Electric Heat Box; GB= Gas Box; PB=

Prop Exhaust Box; Location Device ID McQuay Part # DescriptionGB AS 033003800 Ctrl-press air switch gas burner

GB AS 067297701 Conduit fitting nipple 1-2 3-4GB FLC 193423703 Control Temp Fan Limit Gas HeatGB FSG 073300702 Ctrl-temp flame safegrd base

GB FSG 073300803 Ctrl-temp Flame Safegrd ControlGB FSG 073300901 Ctrl-temp flame safegrd amplifierGB FSG 073301002 Ctrl-temp flame safegrd timer 90

GB IT 034482600 Transformer IgnitionGB LS1 059975301 Limit switchGB LS2 059975301 Limit switch

GB R20A 349934764 DPDT Relay 15A 120VACGB R20A 349964702 Mounting Adapter 2P Relay to DinraGB S3 033536700 Switch Toggle 4PST 125V

MB REC1 039003600 Receptacle Ground Fault InterrupterMB RES1 044690151 RESISTOR 1500 Ohm 1-8 Watt 1% PrMB RES2 044690110 RESISTOR 1000 Ohm 1-8 Watt 1% Pr

MB RES4 044690151 RESISTOR 1500 Ohm 1-8 Watt 1% PrMB S1 018446400 Switch Toggle DPST 125VMB S7 193412101 Switch Toggle 2position ON-ON S

MB SPS2 910117463 SENSOR, AIR PRESSURE/VELOCITY, DIN

MB T1 099477106 MICRON Transformer, CPT, W/ FB, 150MB T1 099477601 Cover, Terminals, Micron 6-terminal

MB T1 099477401 Cover, Fuseholder, Micron Type 2 TrMB T1 040500320 Washer, 1/4" FlatMB T1 193444904 Washer, Split Lock

MB T2 349937303 Transformers 75va 120V-24VacMB T3 349937303 Transformers 75va 120V-24Vac

MB BNMS 193408302 Communication Card, BACnet-MSTP, MTMB DHL 065493801 Pressure Switch SPDTMB DS1 193585102 Circuit Breaker Molded Case Switch

MB DS1 193556201 lug kit, 3 pcs with power control tMB DS1 193404101 Connector 1-4 quick connect tabMB DS1 193553301 lug kit, 3 pcs, T3 Frame, 225A

MB DS1 349939015 SCREW, PANHEAD AB-type, #8-18 X 3"MB DS1 193550801 Circuit Breaker Operating MechanismMB DS1 193422102 HANDLE, PISTOL, ABB DISCONNECT,

REDMB DS6 193443801 Fuse holder, Circuit Protector, 2 PMB DS6 349937131 Fuse 10A Rejection TypeMB EXP-B 193407501 Extension I-O 2 15 Points

MB EXP-B 193409701 Connector for extension I-O - DirecMB EXP-C 193407501 Extension I-O 2 15 PointsMB EXP-C 193409701 Connector for extension I-O - Direc

MB F11 349937127 Fuse 7A Rejection TypeMB F1A 349937129 Fuse 8A Rejection TypeMB F1B 349937129 Fuse 8A Rejection Type

MB F1C 349937035 Fuse 15A Midget Non-Rejection Ty

MB F21 349937127 Fuse 7A Rejection TypeMB F3 349937035 Fuse 15A Midget Non-Rejection Ty

MB FB10 193403115 Fuse 80A 600V Class J Fast ActinMB FB20 099488614 Fuse, 30A 600V Class CC Type T FastMB FB2M 193403114 Fuse, 70A, 600V, Class J Fast Actin

MB M1 193537305 Contactor IEC 32A 120VAC Coil SprinMB M1 193546001 MMP to Contactor Link Module ScrewMB M1 193545801 MMP to Contactor Spacer Size S0

MB M1 349939016 SCREW, PANHEAD B-type, #8 X 1"MB M3 193537305 Contactor IEC 32A 120VAC Coil SprinMB M3 193546001 MMP to Contactor Link Module Screw

MB M3 193545801 MMP to Contactor Spacer Size S0MB M3 349939016 SCREW, PANHEAD B-type, #8 X 1"MB MCB 193407301 Base Controller with IP and Inbuilt

MB MMP1 193543011 MMP Class 10 Size S0 17 to 22A ScreMB MMP1 193543801 MMP Auxiliary Contact Sizes S00 andMB MMP1 193544301 MMP Bus Bar 2 Position No Lateral A

MB MMP1 193545101 MMP Bus Bar Type E Feeder TerminalMB MMP3 193543011 MMP Class 10 Size S0 17 to 22A ScreMB MMP3 193543801 MMP Auxiliary Contact Sizes S00 and

MB OAER 349934722 DPDT Relay 10A 24VACMB OAER 349934822 Relay Socket DPDTMB PB11 030372777 Distribution Power Terminal Brd 17

MB R11 349934724 DPDT Relay 10A 120VACMB R11 349934822 Relay Socket DPDTMB R17 349934724 DPDT Relay 10A 120VACMB R17 349934822 Relay Socket DPDT

MB R22 349934724 DPDT Relay 10A 120VACMB R22 349934822 Relay Socket DPDTMB R24 349934724 DPDT Relay 10A 120VAC

MB R24 349934822 Relay Socket DPDTMB R25 349934724 DPDT Relay 10A 120VACMB R25 349934822 Relay Socket DPDT

MB R26 349934722 DPDT Relay 10A 24VACMB R26 349934822 Relay Socket DPDTMB R28 349934722 DPDT Relay 10A 24VAC

MB R28 349934822 Relay Socket DPDTMB R37 349934724 DPDT Relay 10A 120VACMB R37 349934822 Relay Socket DPDT

MB R63 349934923 3PDT Relay 10A 120VACMB R63 349935021 Relay Socket 3PDT

Page 134: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 134

TB1

R24 R63

MCBCOM

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller

Code 12= *E, *F, *W- Diagram 1

1 The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL1

- PL4

3 Pl

ugs

See Power Panel

See

Pow

er P

anel

Page 135: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 135

Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) 193407301 1 Connector, Extension I/O Direct Connect 1 193409701 2

Terminal Block, MCB- 2 Pole 193410302 1 Terminal Block, MCB- 3 Pole 193410303 6 Terminal Block, MCB- 5 Pole 193410305 1 Terminal Block, MCB- 6 Pole 193410306 1 Terminal Block, MCB- 7 Pole 193410307 1 Terminal Block, MCB- 8 Pole 193410308 2 - MicroTech III Remote Unit Keypad/Interface Display 1 193408003 1 Expansion Module EXP A Expansion Module- Condenser/Energy Recovery 1 193407501 1 EXP B Expansion Module- Heat 193407501 1 EXP D Expansion Module- Specials 1 , 2 193407501 1 Terminal Block, EXP- 2 Pole 193410302 1/board Terminal Block, EXP- 3 Pole 193410303 1/board Terminal Block, EXP- 7 Pole 193410307 1/board Terminal Block, EXP- 8 Pole 193410308 2/board Hot Gas Reheat 1

RHB1, 2 Hot Gas Reheat Interface Boards Code 54= BM, BL 113168901 2 Communication Card COM Bacnet- MSTP Code 12= BE, BF, BW 090016710 1 Bacnet- IP Code 12= EE, EF, EW 090016709 1 LonWorks- Discharge Code 12= LE, LW 090016712 1 LonWorks- Constant Volume Code 12= LF 090016711 1 Resistors 1

RES1 Resistor- Refrigeration Circuit #1 1500 OHM 044690151 1 RES2 Resistor- Refrigeration Circuit #2 1000 OHM 044690110 1 RES3 Resistor- Freezestat (FS1) 1000 OHM 044690110 1 RES4 Resistor- OAE 1500 OHM 044690151 1 RES6,7,8 Resistor- SPS1, SPS2, SPS3 500 OHM 044690146 1/switch Switches- Control HS1 Switch- Electric Heat Shutdown 1 Code 04= E 001355000 1 S1 Switch- System On/Off Gas Heat Units with no UV Lights DPST/15A 018446400 1 Gas Heat Units with UV Lights 4PST/30A 033536700 1 Electric, Steam, HW, No Heat with no UV Lights SPST/20A 001355000 1 Electric, Steam, HW, No Heat with UV Lights DPST/15A 018446400 1 S4 Switch- Inverter Bypass On/Off 1 DPST/15A 018446400 1 S7 Switch- Local On/Auto/Off to Controller SPDT/15A 193412101 1 Transformers T2 Transformer- Control 120- 24V 349937303 1 T3 Transformer- Control 120- 24V 349937303 1 Duct Hi Limit and Duct Static Pressure Sensors DHL Duct Hi Limit Switch 065493801 1 SPS1, 2 Pressure Transducer- Duct Sensor 3 910117462 2

Pressure Transducer- Space Sensor 3 910117463 2

1 Not Shown on diagram. 2 Quantity varies depending upon unit size and options selected.3 SPS1 Duct Sensor Code 13= 1, 2, 3. SPS2 Duct Sensor Code 13= 2. SPS2 Space Sensor Code 13= 3, 4.

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller

Code 12= *E, *F, *W- Components

Page 136: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 136

Sch. Part Part Qty. Sym. Description Number Relays R11 Relay- SpeedTrol inverter VFD11 349934724 1 R12 Relay- Condenser Fan 349934724 1 R13 Relay- Condenser Fan 349934724 1 R14 Relay- Condenser Fan 349934724 1 R17 Relay- SpeedTrol inverter VFD21 349934724 1 R20 Relay- Heat 349934724 1 R22 Relay- Gas Heat 349934724 1 R24 Relay- Gas Heat Alarm 349934724 1 R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1,2,3,5,6,7 349934724 1 R26 Relay- Iso Damper- Open/Close 349934722 1 R28 Relay- Isolation Damper Safety 349934722 1 R45 Relay- UV Lights 349934722 1 R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 14= 1, 3, 6 0 OR 1 Duct Sensor Code 13= Y, 1 349934724 1 2 Duct Sensors Code 13= 2 349934923 1 1 Duct & Space Sensor OR 1 Space Sensor Code 13= 3, 4 349934923 1 DHL Sensor Code 13= 5 349934921 1 Units with Supply & Return Fan Inverters Code 14= 2, 5, 7 Vars. Code 13= 1, 2, 3, 4, Y 349934923 1 R81 Relay- Inverter Reset 4P/6A/24V 349934722 1 R82 Relay- Inverter Reset 4P/6A/24V 349934722 1 R83 Relay- Smoke 4P/6A/24V 193413601 1 R84 Relay- Smoke 4P/6A/24V 193413601 1 R85 Relay- Smoke 4P/6A/24V 193413601 1 R86 Relay- Smoke 4P/6A/24V 193413601 1 R87 Relay- Smoke 4P/6A/24V 193413601 1 R88 Relay- Smoke 4P/6A/24V 193413601 1 Time Delays TD20 Time Delay- Return Air Fan 028210106 1 Terminal Block TB1 Terminal Block 349930641 1

Sensors ZNT1 Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj. 4 910143408 1 Sensor- Zone Temperature w/ Tenant Override 4 113117701 1 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj. 2, 4 113117801 1 DAT Sensor- Discharge Air Temperature 3 193414602 1 EFT Sensor- Entering Air Temperature 3 193414602 1 OAT Sensor- Outside Air Temperature 3 193414602 1 RAT Sensor- Return Air Temperature 3 193414602 1 EAT Sensor- Exhaust Air Temperature 3 193414602 1 LAT Sensor- Leaving Air Temperature 3 193414602 1

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller

Code 12= *E, *F, *W- Components, Continued

10

50

1456

22

68

30

86

2680

°F

°C

62 7418

ZNT1 Sensor910143408

ZNT1 Sensor113117701

ZNT1 Sensor113117801

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647.2 SCC Units only (Code 12= *F).3 Not Shown on diagram.4 Digital Room Sensor p/n 910143408 is the preferred option. The other Zone Temperature Sensors are available as options.

For positive p/n identification, refer to the drawings below.

Page 137: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 137

PB11

REC1

F11 F22 PVM1

F1C

F1B

F1C

Section N- Main Control BoxPower Panel

Diagram

1 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL1

- PL4

3 Pl

ugs

See

Con

trol

Pan

el See Control Panel

Page 138: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 138

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Terminal Blocks TB2,3,4,7 Terminal Block 349930641 1 1 1 1

Transformer- Main 2

T1 Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights 038253974 1 Units without UV Lights 038253956 1 1 Units without UV Lights 038253983 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253975 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253957 1 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253984 1 Gas Heat Code 04= A Units without UV Lights 038253975 1 Units without UV Lights 038253957 1 1 Units without UV Lights 038253984 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253976 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253958 1 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253985 1 Fuses- T1 F1A, B Fuse- T1 Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights 349937132 2 Units without UV Lights 349937131 2 Units without UV Lights 349937124 2 Units without UV Lights 349937129 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937134 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937133 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937129 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937125 2 Gas Heat Code 04= A Units without UV Lights 349937134 2 Units without UV Lights 349937133 2 Units without UV Lights 349937129 2 Units without UV Lights 349937125 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937135 2 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937131 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937130 2 F1C Fuse- T1 Transformer 349937036 3 1 1 1 1 Fuse- T1 Transformer 349937035 3 1 1 1 1 Fuse- T1 Transformer 349937033 3 1 1 1 1

Power Panel- Terminal Blocks, T1 Transformer & Fusing

Section N- Main Control BoxPower PanelComponents

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647. When required TB2, 3, 4, 7 use Jumper p/n 349930922 (2 pole), 349930923 (3 pole), 349930924 (4 pole), 349930925 (5 pole).

2 T1 transformers also use Fuse Puller Kit p/n 349955801 & Cover Kit p/n 349955901.3 Fuse depends on heat type and presence of UV lights. 349937036= Gas Heat Unit w/UV lights; 349937035= Gas Heat Unit with no

UV lights OR Non-Gas Heat Unit with UV lights; 349937033= Non- Gas Heat Units with no UV lights.

Page 139: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 139

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Fuses, continued F2,F3, F5 Fuses Fuse Block 023780223 1/fuse 1/fuse 1/fuse 1/fuse Fuse Cover 349938227 1/fuse 1/fuse 1/fuse 1/fuse F2 Fuse- 2000+VA transformer 349937035 1 1 1 1 F3 Fuse- Blower Motor Code 04= A 349937035 1 1 1 1 F5 Fuse- UV Lights Code 17 (2nd digit)= 1- 8 349937032 1 1 1 1 Phase Voltage Monitor Code 17= P,A,C,D,H,J,K PVM1, 2 Phase Voltage Monitor (12/16 & Earlier) 112022001 2 2 2 Phase Voltage Monitor (12/16 & Earlier) 112022002 2 Phase Voltage Monitor (1/17 & Later) 193599301 2 2 2 Phase Voltage Monitor (1/17 & Later) 193599303 2 - Socket, PVM (1/17 & Later) 193599401 2 2 2 2 Ground Fault Protection Code 17= G,B,C,D,K GFR1, 2 Ground Fault Relay- SPDT 349937502 1 1 1 1 GFS1, 2 Ground Fault Sensor 349937407 1 1 1 1 Power Blocks PB1, PB2 Power Block- Main Code 11= P1, Q1 Power Block, Non- Electric Heat Units- 175A 1 030372776 1 1 1 1 Power Block, Electric Heat Units- 175A 1 030372780 1 1 1 1 Lug- 175A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 255A 1 030372778 1 1 1 1 Lug- 255A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 380A 1 030372779 1 1 1 1 Power Block, Electric Heat- 380A 1 030372782 1 1 1 1 Lug- 380A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 620A 1 030372702 1 1 1 1 Cover- 620A Block 349938345 3 3 3 3 Lug- 620A Block 349938002 1 1 1 1 Power Block, Non- Electric Heat Units- 760A 1 030372760 1 1 1 1 Power Block, Electric Heat Units, 208/230V- 760A 1 030372772 1 1 Power Block, Electric Heat Units, 460/575V- 760A 1 030372760 1 1 Cover- 760A Block 349938345 3 3 3 3 Lug- 760A Block 349938003 1 1 1 1 Power Block, Non- Electric Heat Units- 840A 1 030372724 1 1 1 1 Cover- 840A Block 349938345 3 3 3 3 Lug- 840A Block 349938003 1 1 1 1 PB11 Power Block- Power Distribution Power Block- 420A 1 030372785 1 1 1 1 Power Block- 760A 1 030372721 1 1 1 1 Cover- 760A Block 349938345 1 1 1 1 PB12 Power Block- Power Distribution Code 04= E 20, 40 KW Electric Heat 030372777 1 1 1 1 60, 80, 100, 120 KW Electric Heat 030372785 1 1 60, 80, 100, 120 KW Electric Heat 030372777 1 1 160 KW Electric Heat 030372785 1 1 1 1 200, 240 KW Electric Heat 030372785 1 1

Power Panel- Fusing, Phase Protection, Ground Fault, Power Blocks

1 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. PB2 is installed when Code 11= Q1.

Section N- Main Control BoxPower Panel

Components, Continued

Page 140: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 140

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Power Blocks, continued PB10 Power Block- Supply Fan Code 15= F 030372776 1 1 1 1 PB20 Power Block- Return Fan Code 15= F 030372776 1 1 1 1 Receptacle REC1 Receptacle 039003600 1 1 1 1 PL1- 43 Plugs 1 2 4 Pin Plug 349930201 varies varies varies varies 3 6 Pin Plug 349930403 varies varies varies varies 4 12 Pin Plug 349930405 varies varies varies varies 5 3 Pin Cap Kit 349930501 varies varies varies varies 6 6 Pin Cap Kit 349930503 varies varies varies varies 7 9 Pin Cap Kit 349930504 varies varies varies varies 8 15 Pin Cap Kit 349930506 varies varies varies varies

Power Panel- Power Blocks, continued, Receptacle, Plugs

Section N- Main Control BoxPower Panel

Components, Continued

1 All possible Plugs used are listed. Check actual unit to verify which Plug is required.2 Used for PL1, PL, 2, PL3, PL4, PL5, PL6, PL22,PL23, PL24, PL37, PL38.3 Used with strain relief (p/n 300041173) & 6 pin cap kit (p/n 349930503). Used for PL20, PL21.4 Used for PL11, PL12, PL25, PL26, PL27, PL28, PL29, PL30 (PL11 & 12 also use Strain Relief p/n 300041175 & Cap Kit p/n

349930505).5 Used for PL16, PL17, PL31, PL32, PL33, PL34, PL39, PL40, PL41, PL42. 6 Used for PL9, PL10. 7 Used for PL18, PL19, PL35, PL36, PL43. 8 Used for PL7, PL8.

Page 141: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 141

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch 1

DS1, 2 Disconnect Switch- Main, RAF & SAF Switch- 100A 193444703 1 1 1 1 Handle 193422102 1 1 1 1 Shaft 2 193596420 1 1 1 1 Switch- 150A 193585101 1 1 1 1 Handle 193422102 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft 2 193596420 1 1 1 1 Lugs 4 193553301 1 1 1 1 Switch- 250A 193551601 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193553801 1 1 1 1 Switch- 400A 193551701 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193554001 1 1 1 1 Switch- 600A 193551801 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193554101 2 2 2 2 Switch- 800A 193551901 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193558201 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193557001 2 2 2 2 Switch- 1000A 193552001 1 1 1 1 Handle 193588001 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193555801 2 2 2 2

Section N- Main Control BoxPower Panel

Components, ContinuedPower Panel- Disconnect Switch DS1, 2

1 Disconnects are sized according to various unit specifications. Check installed switch to verify the correct Disconnect size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified.

2 This Shaft is 14.25” OAL and is designed to be cut to length in the field.3 This Shaft is 7.21” (183mm) OAL and is designed to be cut to length in the field. For a 19.69” (500mm) OAL use p/n 300040299.4 Three Lugs are included with each p/n.

Page 142: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 142

Section N- Main Control BoxPower Panel

Supply MMP10 & M10 Fan ContactorReturn MMP20 & M20 Fan Contactor

Diagrams

MMP

3

Link 3B

Contactor

1

Front Mtd.Aux. Contact

2

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

2 HP Motors- All Voltages3, 5 HP Motors- 460/575V

7.5 HP Motors- 575V

NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination.

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

3, 5 HP Motors- 208/230V7.5 HP Motors- 208/230/460V10 HP Motors- All Voltages

15, 20 HP Motors- 460V

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

20, 25, 30 HP Motors- 208/230V40 HP Motors- 460V

50 HP Motors- 460/575V

MMP

3

4A4

Contactor

1

MMP

2

Contactor1

3MMP 3

Contactor1

MMP10 & M10 Link DetailMMP20 & M20 Link Detail15 HP Motors- 208/230/575V

20, 40 HP Motors- 575V25, 30 HP Motor- 460/575V

3EPhase Barrier

Spacer3A

3EPhase Barrier

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

Front Mtd.Aux. Contact

2

Contactor

1

Link 3B

3EPhase Barrier

Overload

TerminalBlock

MMP10 & M10 Link Detail40, 50 HP Motors- 208/230V

3Circuit Breaker

(not shown)

Page 143: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 143

3 HP Motor- Code 22 OR 32= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 1 2 Aux. Contact- 1 NC OR NO 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543007 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542910 1 1 3A Spacer 193545801 1 1 3B Link 193546001 1 1 Link 193545901 1 1 3E Phase Barrier 193545501 1 1 1 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 15A 349937133 3 Fuse- Supply OR Return Fan 10A 349937131 3 Fuse- Supply OR Return Fan 7A 349937127 3 Fuse Cover/Puller 349938227 2 2 2

208V

230V

460V

575V

N/S= Not Shown on Diagram. 2 1 pc. PER Fuse.

Section N- Main Control BoxPower Panel

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M20 Contactor- Return Fan 9A 193534106 1 Contactor- Return Fan 7A 193534105 1 1 1 2 Aux. Contact- 1 NC OR NO 193543801 1 1 1 1 3 MMP20 MMP- Return Fan 5.5- 8A 193542912 1 MMP- Return Fan 4.5- 6.3A 193542911 1 MMP- Return Fan 2.2- 3.2A 193542908 1 MMP- Return Fan 1.8- 2.5A 193542907 1 3B Link 193545901 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 CB20 Circuit Breaker- Return Fan 15A 193550201 1 N/S FB20 Fuseblock- Return Fan 023780232 1 1 1 Fuse- Return Fan 10A 349937131 3 Fuse- Return Fan 9A 349937130 3 Fuse- Return Fan 4A 349937123 3 Fuse Cover/Puller- Return Fan 349938227 1 1 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 1 pc. PER Fuse.

2 Horsepower Motor- Code 22= G*Y

Page 144: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 144

Section N- Main Control BoxPower Panel

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 Contactor- Supply (M10) OR Return (M20) Fan 193534106 1 2 Aux. Contact- 1 NC OR NO 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543012 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543011 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543008 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542913 1 3A Spacer 193545801 1 1 1 3B Link 193546001 1 1 1 Link 193545901 1 3E Phase Barrier 193545501 1 1 1 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse - Supply OR Return Fan 35A 113085249 3 3 Fuse - Supply OR Return Fan 15A 349937133 3 Fuse Cover 193428602 1 1 Fuse Cover/Puller 349938227 2

208V

230V

460V

575V

N/S= Not Shown on Diagram. 2 1 pc. PER Fuse.

7.5 HP Motor- Code 22 OR 32= K*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 Contactor- Supply (M10) OR Return (M20) Fan 193592006 1 Contactor- Supply (M10) OR Return (M20) Fan 193534106 1 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 2 Aux. Contact- 1 NC OR NO 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543009 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542912 1 1 3A Spacer 193545801 1 1 3B Link 193546001 1 1 Link 193545901 1 1 3E Phase Barrier 193545501 1 1 1 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 25A 349937136 3 Fuse- Supply OR Return Fan 20A 349937135 3 Fuse- Supply OR Return Fan 10A 349937131 3 Fuse Cover/Puller 349938227 1 1 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 1 pc. PER Fuse.

5 HP Motor- Code 22 OR 32= J*Y

Page 145: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 145

Section N- Main Control BoxPower Panel

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

10 HP Motor- Code 22 OR 32= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537305 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193592006 1 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 2 Aux. Contact- 1 NC OR NO 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543014 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543013 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543009 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543008 1 3A Spacer 193545801 1 1 1 1 3B Link 193546001 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse- Supply OR Return Fan 50A 113085252 3 Fuse- Supply OR Return Fan 45A 113085251 3 Fuse- Supply OR Return Fan 20A 349937135 3 Fuse Cover- Supply OR Return Fan 193428602 1 1 Fuse Cover/Puller- Supply Fan 349938227 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 1 pc. PER Fuse.

Page 146: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 146

Section N- Main Control BoxPower Panel

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

15 HP Motor- Code 22 OR 32= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591602 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 Contactor- Supply (M10) OR Return (M20) Fan 193598101 1 2 Aux. Contact- 1 NC OR NO 193546201 1 1 1 Aux. Contact- 1 NC OR NO 193543801 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543306 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543305 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543010 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543301 1 3A Spacer 193545801 1 3B Link 193547401 1 1 1 Link 193546001 1 3E Phase Barrier 193545501 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 20A 193550202 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 349964253 1 Fuseblock- Supply OR Return Fan 193428502 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse - Supply OR Return Fan 70A 113085254 3 Fuse - Supply OR Return Fan 60A 113085253 3 Fuse - Supply OR Return Fan 30A 349937137 3 Fuse Cover 349964263 1 Fuse Cover 193428602 1 Fuse Cover/Puller 349938227 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 1 pc. PER Fuse.

Page 147: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 147

25 HP Motor- Code 22 OR 32= P*Y

Section N- Main Control BoxPower Panel

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591702 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193591601 1 Contactor- Supply (M10) OR Return (M20) Fan 193598102 1 2 Aux. Contact- 1 NC OR NO 193546201 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543404 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543403 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543304 1 1 3B Link 193547501 1 1 Link 193546001 Link 193547401 1 1 3E Phase Barrier 193547301 1 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 90A 193550209 1 Circuit Breaker- Supply OR Return Fan 80A 193550208 1 Circuit Breaker- Supply OR Return Fan 40A 193550204 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 Fuse - Supply OR Return Fan 50A 113085252 3 Fuse Cover 193428602 1

208V

230V

460V

575V

N/S= Not Shown on Diagram.

20 HP Motor- Code 22 OR 32= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591701 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193537305 1 Contactor- Supply (M10) OR Return (M20) Fan 193598101 1 2 Aux. Contact- 1 NC OR NO 193546201 1 1 1 Aux. Contact- 1 NC OR NO 193543801 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543403 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543013 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543303 1 3A Spacer 193545801 1 3B Link 193547501 1 1 Link 193546001 1 Link 193547401 1 3E Phase Barrier 193547301 1 1 Phase Barrier 193545501 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 70A 193550207 1 Circuit Breaker- Supply OR Return Fan 60A 193550206 1 Circuit Breaker- Supply OR Return Fan 30A 193550203 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 Fuse- Supply OR Return Fan 40A 113085250 3 Fuse Cover- Supply OR Return Fan 193428602 1

208V

230V

460V

575V

N/S= Not Shown on Diagram.

Page 148: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 148

Section N- Main Control BoxPower Panel

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591703 1 Contactor- Supply (M10) OR Return (M20) Fan 193591702 1 Contactor- Supply (M10) OR Return (M20) Fan 193591601 1 Contactor- Supply (M10) OR Return (M20) Fan 193598102 1 2 Aux. Contact- 1 NC OR NO 193546201 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543405 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543305 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543304 1 3B Link 193547501 1 1 Link 193546001 Link 193547401 1 1 3E Phase Barrier 193547301 1 1 CB10, 20 Circuit Breaker- Supply OR Return Fan 125A 193550301 1 Circuit Breaker- Supply OR Return Fan 90A 193550209 1 Circuit Breaker- Supply OR Return Fan 40A 193550204 1 N/S FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 Fuse - Supply OR Return Fan 60A 113085253 3 Fuse Cover 193428602 1

30 HP Motor- Code 22 OR 32= Q*Y

208V

230V

460V

575V

40 HP Motor- Code 32= R*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 115A 193591801 1 1 Contactor- Supply Fan 65A 193591701 1 Contactor- Supply Fan 50A 193591602 1 2 Aux. Contact- 1 NC OR NO 193546201 1 1 3 MMP10 Circuit Breaker- Supply Fan 150A 193550302 1 1 MMP- Supply Fan 36- 50A 193543402 1 MMP- Supply Fan 28- 40A 193543305 1 3B Link 193547501 1 Link 193547401 1 3C Lugs- MMP10 (kit of 3pc.) 193556201 1 3E Phase Barrier 193547301 1 1 4 OL10 Overload- Supply Fan 50- 200A 193549702 1 4A Terminal Block- Supply Fan 193542601 2 2 CB10 Circuit Breaker- Supply Fan 150A 193550302 1 Circuit Breaker- Supply Fan 125A 193550301 1 Circuit Breaker- Supply Fan 60A 193550206 1 Circuit Breaker- Supply Fan 50A 193550205 1 N/S Lugs- CB10 (kit of 3pc.) 193553301 1 1 N/S= Not Shown on Diagram.

N/S= Not Shown on Diagram.

208V

230V

460V

575V

Page 149: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 149

Section N- Main Control BoxPower Panel

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

50 HP Motor- Code 32= S*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 150A 193591802 1 1 Contactor- Supply Fan 65A 193591701 1 1 2 Aux. Contact- 1 NC OR NO 193546201 1 1 3 MMP10 Circuit Breaker- Supply Fan 150A 193550302 1 1 MMP- Supply Fan 45- 63A 193543403 1 MMP- Supply Fan 36- 50A 193543402 1 3B Link 193547501 1 1 3E Phase Barrier 193547301 1 1 4 OL10 Overload- Supply Fan 50- 200A 193549702 1 1 4A Terminal Block- Supply Fan 193542601 2 2 CB10 Circuit Breaker- Supply Fan 80A 193550208 1 Circuit Breaker- Supply Fan 60A 193550206 1 N/S FB10 Fuseblock- Supply Fan 113085301 1 1 Fuse - Supply Fan 225A 113085205 3 Fuse - Supply Fan 175A 193559501 3

208V

230V

460V

575V

N/S= Not Shown on Diagram.

Page 150: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 150

045

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1, 3 Contactor- Compressor 40A 193591601 2 2 Contactor- Compressor 32A 193537305 2 Contactor- Compressor 25A 193598101 2

1A Front Mounted Contact- 2NO- 2NC 193542701 2 2 2

Compressor MMP’s & Parts 2 Front Mounted Contact- 2NO- 2NC 193546201 2 2 2 Front Mounted Contact- 2NO- 2NC 193543801 2

3 MMP1, 3 Motor Protector- Compressor 36- 45A 193543306 2 Motor Protector- Compressor 28- 40A 193543305 2 Motor Protector- Compressor 17- 22A 193543011 2 Motor Protector- Compressor 11- 16A 193543301 2

3B Link 193547401 2 2 2 Link 193546001 2

N/S Busbar 193546601 2 2 2 Busbar 193544301 2

N/S Busbar Top Feed 193547201 1 1 1 Busbar Top Feed 193545101 1

208v

230V

460V

575V

MMP1, 3 & M1, 3 Contactor Link Detail208/230/575V

MMP1, 3 & M1, 3 Contactor Link Detail460V

Control BoxPower Panel

Compressor Motor Protector MMP1, 3, 5 and Contactor M1, 3, 5Unit Size 045D

MMP

2

Contactor1

3

MMP 3

Contactor

1

Spacer3A

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

Front Mtd.Aux. Contact 1A

N/S= Not Shown on Diagram.

Page 151: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 151

0 50, 051

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1, 3 Contactor- Compressor 65A 193591701 2 2 Contactor- Compressor 32A 193537305 2 Contactor- Compressor 25A 193598101 2 1A Front Mounted Contact- 1NO- 1NC 193542701 2 2 2

Compressor MMP’s & Parts 2 Front Mounted Contact- 1NO- 1NC 193546201 2 2 2 Front Mounted Contact- 1NO- 1NC 193543801 2 3 MMP1, 3 Motor Protector- Compressor 45- 63A 193543403 2 2 Motor Protector- Compressor 17- 22A 193543011 2 Motor Protector- Compressor 14- 20A 193543302 2 3B Link 193547501 2 2 Link 193546001 2 Link 193547401 2 N/S Busbar, 2 position 193544301 1 Busbar, 2 position 193546601 1 N/S Busbar Top Feed 193545101 1 Busbar Top Feed 193547201 1

208V

230V

460V

575V

Control BoxPower Panel

Compressor Motor Protector MMP1, 3, 5 and Contactor M1, 3, 5Unit Size 050, 051D

MMP

3

Front Mtd.Aux. Contact 2

Contactor

Link 3B

MMP1, 3 & M1, 3 Contactor Link Detail208/230V

MMP

2

Contactor1

3

MMP3

Contactor1

Spacer3A

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

MMP1, 3 & M1, 3 Contactor Link Detail460V

MMP1, 3 & M1, 3 Contactor Link Detail575V

1A Front Mtd. Aux. Contact

Front Mtd.Aux. Contact 1A

1

N/S= Not Shown on Diagram.

Page 152: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 152

063

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1, 3 Contactor- Compressor 65A 193591701 2 2 Contactor- Compressor 40A 193591601 2 Contactor- Compressor 25A 193598101 2 1A Front Mounted Contact- 1NO- 1NC 193542701 2 2 2 2

Compressor MMP’s & Parts 2 Front Mounted Contact- 1NO- 1NC 193546201 2 2 2 2 3 MMP1, 3 Motor Protector- Compressor 45- 63A 193543403 2 2 Motor Protector- Compressor 22- 32A 193543304 2 Motor Protector- Compressor 18- 25A 193543303 2 3B Link 193547501 2 2 Link 193547401 2 2 N/S Busbar, 2 position 193546601 1 1 N/S Busbar Top Feed 193547201 1 1

Control BoxPower Panel

Compressor Motor Protector MMP1, 3, 5 and Contactor M1, 3, 5Unit Size 063D

MMP1, 3 & M1, 3 Contactor Link Detail208/230V

MMP1, 3 & M1, 3 Contactor Link Detail460/575V

MMP 3

Contactor1

Front Mtd.Aux. Contact

Link3B

MMP

3

2

Contactor

1

Link 3B

1A

208V

230V

460V

575V

1A

Front Mtd.Aux. Contact

2

N/S= Not Shown on Diagram.

Page 153: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 153

074

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1, 3, 5 Contactor- Compressor 65A 193591701 3 3 Contactor- Compressor 40A 193591601 3 Contactor- Compressor 25A 193598101 3 1A Front Mounted Contact- 1NO- 1NC 193542701 3 3 3 3

Compressor MMP’s & Parts 2 Front Mounted Contact- 1NO- 1NC 193546201 3 3 3 3 3 MMP1, 3, 5 Motor Protector- Compressor 45- 63A 193543403 3 3 Motor Protector- Compressor 22- 32A 193543304 3 Motor Protector- Compressor 18- 25A 193543303 3 3B Link 193547501 3 3 Link 193547401 3 3 N/S Busbar, 3 position 193544401 1 Busbar, 3 position 193546701 1 N/S Busbar Top Feed 193545101 1 Busbar Top Feed 193547201 1

208V

230V

460V

575V

Control BoxPower Panel

Compressor Motor Protector MMP1, 3, 5 and Contactor M1, 3, 5Unit Size 074D

MMP1, 3, 5 & M1, 3, 5 Contactor Link Detail208/230V

MMP1, 3, 5 & M1, 3, 5 Contactor Link Detail460/575V

MMP 3

Contactor1

Front Mtd.Aux. Contact

Link3B

MMP

3

2

Contactor

1

Link 3B

1A1A

Front Mtd.Aux. Contact

2

N/S= Not Shown on Diagram.

Page 154: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 154

Unit Size 045 050, 051 063 074

Ref. Part No. Number Inverter Compressor Fuseblock 1 193428504 1 1 1 1 1 1 1 1 193428502 1 349964253 1 1 1 1 1 1 1 1 Fuseblock Cover N/S 193445316 1 1 1 1 1 1 1 1 193428602 1 349964263 1 1 1 1 1 1 1 1 N/S Inverter Compressor Fuses 193403120 150A 3 3 3 193403119 125A 3 3 3 3 193403118 110A 3 193403113 60A 3 193403114 70A 3 3 3 1 3 3 3 3

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

N/S= Not shown on diagram.1 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

PB11

REC1

F11 F22 PVM1

F1C

F1B

F1C

Section N- Main Control BoxPower Panel

Inverter Compressor Fuseblock & Fuse Components FB2M

1

Page 155: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 155

SpeedTrol Fusing DetailF11, F12 & M12, M22

Section N- Main Control BoxPower Panel

SpeedTrol Condenser Fan Fusing: Code 47= 2, 4 2

Ref. Sch. Part Part Unit Size No. Sym. Description Number 045 050 051 063 074 SpeedTrol AFD Fusing 9 FB11, 21 Fuse Block 023780232 2 2 2 2 2 9A F11 Fuse Code 47= 2 2

208V 15A 300043312 3 208V 1 3 3 3 3 230V 1 3 3 3 3 3 460V 7A 349937127 3 3 460V 10A 049759816 3 460V 17.5A 349937134 3 575V 1 3 3 3 3 3 9A F21 Fuse Code 47= 2 2 208V 15A 300043312 3 208V 1 3 3 3 3 230V 1 3 3 3 3 3 460V 7A 349937127 3 3 460V 10A 049759816 3 460V 15A 300043312 3 575V 1 3 3 3 3 3 9B - Fuse Cover/Puller 349938227 3 3 3 3 3

Fuse Block

Puller

Fuse

9B

9A 9

1 Contact Daikin Applied with model and serial number information so that the correct fuse can be identified.2 When Code 47= 4 contact Daikin Applied with model and serial number information so that the correct fuse can be

identified.

Page 156: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 156

Unit Voltage

Ref. Sch. Part Part No. Sym. Description Number ERW Contactor & Parts 1

7 M60 Contactor 7A 193534105 1 1 1 7B Link 193545901 1 1 1

Heat Wheel MMP’s & Parts 1

8 MMP60 Motor Protector 3 1 1 1 8E Phase Barrier 193545501 1 1 1

ERW Fusing 2

9 FB60 Fuseblock 023780232 1 1 9A F60 Fuse 3 3 3 9B Fuse Cover/Puller 349938227 3 3 N/S CB60 Circuit Breaker 3 3

208/

230V

460V

575V

Section N- Main Control BoxPower Panel

Heat/Energy Recovery Wheel Contactors, MMPs & Fusing

N/S= Not shown on diagram.1 Units With No Frost Protection Inverter (Code 24= Y).2 Units w/ Frost Protection Inverter (Code 24= F). 3 Contact Daikin Applied with model and serial number information so that the correct

parts(s) can be identified.

7

MMP

8

Link 7B

Contactor

8EPhase Barrier

MMP & Contactor Detail ERW Fusing Detail

Fuse Block

Fuse9A

9

Cover

9B

Page 157: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 157

Section N- Main Control BoxIntelligent Equipment: Code 23= ****A

Intelligent Equipment™ (IE) from Daikin Applied is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation.

A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality.

Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply.

Click on this link to access the RPL for Intelligent Equipment: 7000506.

Page 158: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 158

Primary Codes that pertain: 45, 46, 54

Code 45, Compressor mounting, pertains to the Suction and Discharge Tubing located in the Condenser Section.

Code 46, Hot Gas Bypass, pertains to the Liquid Line tubing. The drawing below shows the Hot Gas Bypass option installed (Code 46= 1, 2, 4, 5). HGBP can be field installed, however it is important to note that any additional piping required for field installed HGBP is ALWAYS field supplied. Code 54 determines if the unit is equipped with Hot Gas Reheat or Modulating Liquid Subcooling Reheat. These options are not shown in the Refrigeration Tubing diagram below.

Refrigeration Piping Schematic

B

A

J

DL K

N

M

H F I

E

P

P

O

A Compressor (1 2 or per circuit) B Discharge line C Condenser coil D Evaporator coil E Manual charging/evacuation valve F Filter-drier H Sightglass I Liquid line J Suction line K Thermal expansion valve L Distributor M Drop solenoid valve N Hot gas bypass valves (optional) O Hot Gas bypass piping (optional) P Manual shutoff valve (optional)Q Condenser Coil Splitter Solenoid Valve

Q

C

Section O- Refrigeration TubingNotes & Refrigeration Piping Schematic

Notes

Page 159: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 159

Section O- Refrigeration TubingRefrigeration Tubing Diagrams

045- 063D(Circuit #1 shown)

145

270

140

140

142

110

Expansion Valve Diagram

Liquid Line Diagram

Hot Gas Bypass (HGBP) Diagram: Code 46= 1, 2, 4, 5

Discharge Line Diagram

016D(Circuit #1 shown)

174

170

470

370

500

Page 160: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 160

Section O- Refrigeration Tubing Valves, Filter Driers, Sight Glasses, & Hot Gas Bypass

Ref. Part Part Unit Size 1

No. Description Number 045 050 051 063 074 Liquid Line Components 140 Sight Glass 015997805 1 1 1 1 Sight Glass 015997806 1 142 Charge/Purge/Shutoff Valve 910120909 1 1 1 1 1 Valve Rebuild Kit 500573001 1 1 1 1 1 145 Filter Drier Sealed Core 098803001 1 1 1 1 Sealed Core 021057426 1 Replaceable Core- Shell 3 001360700 1 1 1 1 Replaceable Core- Shell 3 019190500 1 Replaceable Core- Core 3 001360800 2 2 2 2 2 170, 270 Solenoid, Pilot Valve ALL 113142901 1 1 1 1 Solenoid, Pilot Valve Code 03= S 113143001 1 Solenoid, Pilot Valve Code 03= L 113142801 1 174 Valve Stem 034915300 1 1 1 1 1 370, 470 Expansion Valve- Circuit #1 3 & 5 Row Coils 258946901 1 1 1 4 Row Coils 403589405 1 1 1 3 & 5 Row Coils 403589407 1 4 Row Coils 403589409 1 3 & 5 Row Coils 403589502 1 4 Row Coils 403589504 1 Expansion Valve- Circuit #2 3 & 5 Row Coils 258946901 1 1 1 4 Row Coils 403589405 1 1 1 3 & 5 Row Coils 403589407 1 4 Row Coils 403589409 1 3 & 5 Row Coils 403589502 1 4 Row Coils 403589504 1 N/S Check Valve, .875” 112053305 1 1 1 1 Check Valve, 1.125” 112053304 1

Discharge Line Components 110 Solenoid Valve 910141289 1 Solenoid Valve 910141295 1 1 1 1 140 Shut- Off Valve 113114501 1 1 1 1 Shut- Off Valve 113114601 1

Hot Gas Bypass N/S Hot Gas Bypass Kit 193330721 2 2 2 2 2

500 Valve only, Hot Gas Bypass 258951301 4 4 4 4 4

N/S= Not shown on diagram.1 Quantity is PER circuit. Each unit has two (2) circuits. The components listed are the same for either circuit.2 Each Hot Gas Bypass Kit covers ONE circuit. To add Hot Gas Bypass to BOTH circuits order TWO kits. The Hot Gas

Bypass Kit includes a Solenoid Valve and Instructions. Due to the many possible variations in unit location configurations ANY AND ALL additional piping and wiring required is field supplied.

3 Code 46= 3, 4, 5.4 Code 46= 1, 2, 4, 5. If Code 46= 1, 4 then there is Hot Gas Bypass on Circuit #1 only.

Page 161: Roofpak™ Applied Rooftop Units Inverter Compressor Modelslit.daikinapplied.com/bizlit/DocumentStorage/RooftopSystems/... · Vintage D Code 44= V, W. ... Key, & Lock (All Sections)

Rooftop Inv. Cmpr. Units: RPS, RDT 045-074 Vintage D Rev. I 02/18 RPL 7000513 / Page 161

Section O- Refrigeration Tubing Hot Gas Reheat 1

(Code 54= BM, BL)

200

213

213

212

212

200

Ref. Part Part Unit Size No. Description Number 045 050 051 063 074 200 Microchannel Coil Module 113152801 2 2 2 2 2 Microchannel Coil Module, E-Coated 404047402 2 2 2 2 2 N/S Electronic Step Valve 113167705 1 1 1 1 N/S Electronic Step Valve 113167706 2 N/S Valve- Motor Kit 113167708 1 1 1 1 2 N/S Valve- Washer (order with Motor kit) 300045244 1 1 1 1 2 N/S Sensor 113167904 1 1 1 1 1 211 Coil divider 910100428 1 1 1 1 1 212 Support channel- (Connection side) 113172601 2 2 2 2 2 213 Support channel- (Return side) 113172701 2 2 2 2 2 233 Check Valve, .875” 112053305 1 1 1 1 Check Valve, 1.125” 112053304 1 234 Valve- Bleed Down 404031001 1 1 1 1 1 235 Coil- Bleed Down Valve 404031101 1 1 1 1 1

AirFl

ow

233235

234

N/S= Not Shown on Diagram.1 Hot Gas Reheat is located on Circuit #2 only.


Recommended