TYPICAL
CIRCUIT A
TYPICAL
CIRCUIT B
TYPICAL
CIRCUIT A
TYPICAL
CIRCUIT A
TYPICAL
CIRCUIT B
TYPICAL
CIRCUIT B
(SEE PLANS)
AIM PATTERN
TYPICAL LUMINAIRE
REQUIRED IN TOP SURFACE)
ENTRANCE ARROWS
FOUNDATION (CONDUIT
LUGS IN TOWER
GROUND TO TWO SEPARATE
9
LOCATION, TYPICAL
SEQUENCE PLAQUE
CIRCUIT POLES
ALTERNATE
M
LINE INLINE OUT
TO LUMINAIRES
LOWERING RING
TOWER
TYPE "SO"
TYPE "USE-XLP"
(4 REQUIRED)
ELECTRODE
GROUNDING
EQUIPMENT
(MINIMUM) BARE COPPER
GROUND GRID #2 AWG
1
2
3
4
5
6
7
8
9
10
4
3
9
1
2
5
VARY BY MANUFACTURER.
ONLY. ARRANGEMENTS
FOR INFORMATION
ROLLERS SHOWN
LOWERING RING
THE PLANS
ONLY WHERE SHOWN ON
ADDITIONAL CONDUIT
LOWERING RING WIRE
TYPE "USE-XLP"
ASSEMBLY
PORTABLE LOWERING MOTOR
MOTOR CONTROL
TERMINAL STRIP
LOWERING RING JUNCTION BOX (WEEP HOLE REQUIRED)
CIRCUIT BREAKER ENCLOSURE EQUIPMENT GROUNDING BUS
CIRCUIT BREAKER ENCLOSURE NEUTRAL BUS
CIRCUIT BREAKER
CIRCUIT BREAKER ENCLOSURE
SURGE ARRESTOR - 2P OR 3P AS REQUIRED
LOADBREAK DISCONNECT - MALE APPLIANCE INLET
LOADBREAK DISCONNECT - FEMALE RECEPTACLE
LOADBREAK DISCONNECT - MALE PLUG
RATED FOR NO. 10 AWG THROUGH NO. 2 AWG CU.
MINIMUM 1-TERMINAL NEUTRAL BUS. BUSSES SHALL BE
IN ISOLATED NEUTRAL SYSTEMS, ADDITIONALLY FURNISH A
ALL SYSTEMS, FURNISH A MINIMUM 4-TERMINAL GROUND BUS.
600 VOLT, 2P OR 3P AS REQUIRED, SURFACE MOUNT. IN
CIRCUIT BREAKER ENCLOSURES SHALL BE NEMA 1, 100 AMP,
REQUIRED.
SURGE ARRESTORS SHALL BE 650 VAC, 2P OR 3P AS
INLET).
PLUG ONLY, NOT TO THE RECEPTACLE OR THE APPLIANCE
FURNISH "LP" MOISTURE PROTECTION (APPLIES TO THE
AND RECEPTACLE ONLY, NOT TO THE APPLIANCE INLET).
"FDP" FINGER/PALM DRAW PLATES (APPLIES TO THE PLUG
30 AMP, 600 VOLT. DO NOT SUBSTITUTE. FURNISH
LOADBREAK DISCONNECTS SHALL BE MELTRIC TYPE "DR",
VOLTAGE SHOWN.
CIRCUIT BREAKERS SHALL BE MINIMUM 14 kAIC AT THE
COLOR CODING AS SHOWN IN THE PLANS.
"SO" CABLE MAY BE REQUIRED TO CONFORM TO SYSTEM
FIELD RECODING OF UNGROUNDED CONDUCTORS IN TYPE
CONNECTED TO EACH INSTALLATION.
THE PLANS WILL SHOW WHICH CIRCUIT LEG(S) ARE
LUGS IN THE CIRCUIT BREAKER ENCLOSURE.
OUT DISTRIBUTION SYSTEMS, FURNISH FEED-THROUGH
IN CASES WHERE THE PLANS SHOW LINE IN/LINE
PERTINENT REQUIREMENTS OF THE CONTRACT.
SHOWN IN THIS DRAWING SHALL CONFORM TO THE
DETAILS OF CONSTRUCTION AND WORKMANSHIP NOT
EXOTHERMIC WELD
CONDUCTOR
SPLICE
TERMINAL
EQUIPMENT GROUNDING ELECTRODE
FUSED LUMINAIRE
SURGE ARRESTOR
CIRCUIT BREAKER 1P
HANDHOLE GROUND LUG
VAC SYSTEMS)
(OMIT FOR 120/240
TRANSFORMER
RING AT GROUND LEVEL
COMPONENT #3 WITH LOWERING
AMPERE INTERUPTING CAPACITY
PHASE (ELECTRICAL CURRENT)
POLE (ELECTRICAL CIRCUIT)
EQUIPMENT GROUNDING CONDUCTOR
GROUNDED CIRCUIT CONDUCTORS
UNGROUNDED CIRCUIT CONDUCTORS
1-| 480VAC: 2 WIRE
3-| 208Y/120VAC: 4 WIRE
3-| 480Y/277VAC: 4 WIRE
1-| 240/480VAC: 3 WIRE
1-| 120/240VAC: 3 WIRE
LINE VOLTAGE
1-20A, 2P, 600VAC
3-30A, 1P, 277VAC
3-30A, 1P, 277VAC
2-30A, 1P, 277VAC
2-30A, 1P, 277VAC
BREAKERS
HAND HOLE
5A
20A
10A
10A
20A
FUSES
LUMINAIRE
INDIVIDUAL
10-3 + GND "SO"
10-4 + GND "SO"
10-4 + GND "SO"
10-3 + GND "SO"
10-3 + GND "SO"
CORD
POWER
A,B,N,GND
X,Y,Z,N,GND
X,Y,Z,N,GND
A,B,N,GND
A,B,N,GND
DISCONNECT
LOAD BREAK
PRONGS ONCONDUIT
1" GROUND 3" LINE CONDUIT
MINIMUM
20’GROUND LEVEL
LOWERING RING AT
COMPONENT #1 WITH
LUMINAIRES.
IF FEWER THAN SIX
PLACE COUNTER WEIGHTS
TENONS REQUIRED.
6 EACH, 2�" O.D.
LOWERING RING OPTICS PLAN
ONE LINE DIAGRAM
GENERAL NOTES
FOUNDATION ELECTRICAL DETAILS
EQUIPMENT GROUNDING GRID AND
OVER CURRENT AND POWER CORD SCHEDULE
LEGEND
AIC
|
P
GND
N
A,B,X,Y,Z
1-| CASE SHOWN; 3-| CASE SIMILARAND POWER CORD SCHEDULE
ANY LINE VOLTAGE PER OVER CURRENT
10’\
10’\
DEPARTMENT OF TRANSPORTATION
STATE OF WISCONSIN
66
S.D.D. 10
A
14-2a
HIGH MAST LIGHTING
ELECTRICAL DETAILS
S.D.D. 10
A
14-2a
SDD 10a14-a Electrical Details High Mast Lighting
Electrical Details High Mast Lighting
Version 2 Standard Detail Drawing 10a14 (sheet a) November 17, 2010
Electrical Details High Mast Lighting
References:
NONE
Bid items associated with this drawing:
ITEM NUMBER DESCRIPTION UNIT
659.0400 Luminaries High Mast Lighting ....................................................................... EACH 660.0200 High Mast Lighting Tower (location) .................................................................... LS
Standardized Special Provisions associated with this drawing:
STSP NUMBER TITLE
NONE
Other SDDs associated with this drawing:
SDD 10a1 Electrical Handhole Wiring
Design Notes:
120/240 VAC systems support only 4 luminaries per tower, with no expansion capacity. Otherwise, use 240/480 VAC or 480Y/277 VAC. The Detail shows 6 required luminaire tenons, as 120/240 VAC systems can be converted to higher voltages with minimal changes to the tower wiring systems. Use this SDD in conjunction with the SDD for Electrical Handhole Wiring.
Highmast structure foundations will be designed site-by-site. Highmast shafts and lowering systems will be on the basis of design-build under Standard Spec 660. Only the electrical details shown in this SDD and described in Standard Spec 659 (high mast luminaries) and 660 are standard.
Contact Person:
Ahmet Demirbilek (414) 220-6801
A
B
A A
B B
LINE IN
GROUNDING LUG
EQUIPMENT
(INDIVIDUALLY FUSED)
LUMINAIRE
1
9
10
4
3
TYPE "SO"
LOWERING RING WIRE
TYPE "USE-XLP"
2
6 7
8
TYPE "SO"
TYPE "USE-XLP"
5
TOWER HANDHOLE
LINE IN
2
6 7
8
TYPE "SO"
TYPE "USE-XLP"
5
TOWER HANDHOLE
TYPE "USE-XLP"
#2 AWG
#2 AWG
#2 AWG
#2 AWG
LINE IN
A B N GND
2
6
8
TYPE "SO"
TYPE "USE-XLP"
5
TOWER HANDHOLE
TYPE "USE-XLP"
#2 AWG
#2 AWG
TYPE "USE-XLP"
IN THE PLANS)
(WHERE SHOWN
LINE OUT
IN THE PLANS)
(WHERE SHOWN
LINE OUT
IN THE PLANS)
(WHERE SHOWN
LINE OUT
*
*1-2P BREAKER FOR 480VAC 2 WIRE
LOWERING RING JUNCTION BOX WIRING DIAGRAM
TYPICAL WIRING DIAGRAM-HANDHOLE
TYPICAL WIRING DIAGRAM-HANDHOLE
OR 3-| 208Y/120VAC 4 WIRE
3-| 480Y/277VAC 4 WIRE
ISOLATED NEUTRAL SYSTEM
1-| 240/480VAC 3 WIRE OR 480VAC 2 WIRE
GROUNDED NEUTRAL SYSTEM
TYPICAL 1-| CASE SHOWN; 3-| CASE SIMILAR
1-| 120/240VAC OR 240/480VAC 3 WIRE
ISOLATED NEUTRAL SYSTEM
WIRING DIAGRAM-HANDHOLE
TYPICAL
A
B
N
A
B
N
X Y Z N GND
X
Y
Z
N
GNDGND
N
Z
Y
X
A B N GND
A
B
N
GND GND
N
B
A
A B N GND
10/25/2010 /S/ John Corbin
DEPARTMENT OF TRANSPORTATION
STATE OF WISCONSIN
APPROVED
DATE
FHWA
66
STATE ELECTRICAL ENGINEER FOR HWYS
S.D.D. 10
A
14-2b S
.D.D. 10
A
14-2
b
HIGH MAST LIGHTING
ELECTRICAL DETAILS
SDD 10a14-b Electrical Details High Mast Lighting
Electrical Details High Mast Lighting
Version 2 Standard Detail Drawing 10a14 (sheet b) November 17, 2010
Electrical Details High Mast Lighting
References:
NONE
Bid items associated with this drawing:
ITEM NUMBER DESCRIPTION UNIT
NONE
Standardized Special Provisions associated with this drawing:
STSP NUMBER TITLE
NONE
Other SDDs associated with this drawing:
SDD 10a14 Electrical Details High Mast Lighting sheet "a" must be used in conjunction with this drawing.
Design Notes:
See guidance for SDD 10a14 sheet "a".
Contact Person:
Ahmet Demirbilek (414) 220-6801