Date post: | 31-Mar-2015 |
Category: |
Documents |
Upload: | ryder-brewton |
View: | 214 times |
Download: | 2 times |
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 1
Central Control Equipment
LBB3500/05
LBB4106/x0
LBB3508/00
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 2
Central Control Unit (Com - port 1)
LBB3500/05 9-pin Sub-D connector
RS 232 for: Terminal mode
Factory testing Diagnostics
OR Camera Control
1
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 3
CCU Trunk Communication Board (TCB-4)1 Jumper X14 for service only
2 S14 DIP- switches 1 – 8 Com-port settings
3 S10 Push- button switch to reset the Central Control Unit during servicing.
4 Three LEDs (left to right) green/ yellow/ red. Normally the green/ yellow LEDs flash in sequence, indicating the software is running. Red LED illuminates during system reset.
5 S9 DIP- switches 1 – 8 System modes
6 Yellow LED indicates Digital Signal Processing (DSP) software is running.
7 Connector for multi- trunk board (used only in the multi- CCU)
8 Sockets for inserting flash EPROM (even)
9 Sockets for inserting flash EPROM (odd)
Upgrade Kit
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 4
CCU Trunk Communication Board (TCB-4)10 SRAM back- up battery 3.6 V (life- time 5 years min.)
11 Jumper X13 Battery back up
12 Fuse 3.15 amp (delayed)
13 Connector for multi- trunk board (used only in the multi- CCU)
14 Serial RS232 Port 1
15 Serial RS232 Port 2
Upgrade Kit
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 5
Central Control Unit (Com - port 1) LBB3500/05
CCU Protocol and Serial Port settings - Protocol based for using Allegiant Video Switchers.For location of DIP- switches see;Table 4.5 and 4.6
LBB 3500/ 05 Port 1 for Camera ControlIn a single (stand- alone) CCU system only one COM- port (Port 1) is available:
Default settings are;• 8 data bits• No parity check• 1 Stop bit
InstallationThe maximum cable length between the CCU and the ‘Allegiant Video Switcher’ should not exceed 5 m (16.4 ft). Where longer distances are required an ‘current-loop interface unit’ should be used to ensure correct transmission.
I&O Manual
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 6
TCB-4 DIP Switch Settings
(default)
I&O Manual
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 7
Central Control Unit (Audio I/O)LBB3500/05
1. Asymmetrical Recorder In- & Outputs
2. 2 Asymmetrical line
input connectors
3. Symmetrical or 2 Asymmetrical line outputs
1
2
3
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 8
Central Control Unit (Audio I/O) LBB3500/05
1. Tape/cassette recorder input and output (Cinch-type)Tape In Asym. nom. -33 dBV max. -3 dBVTape Out Asym. nom. -33 dBV max. -3 dBV
2. 2 Asymmetrical line input connectors (Cinch-type)
Line In Asym. nom. -18 dBV max. +12 dBV
3. Symmetrical/Asymmetrical line output connectors (Cinch-type)
Line Out Sym. nom. -12 dBV max. +18 dBV Line Out Asym nom. -18 dBV max. +12 dBV
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 9
11
22
Trunk
Central Control Unit LBB3500/05 (Trunk Outlets)
1. Red LED overload indicators
2. Trunk outlet used for loop-through of the trunk-line-cable
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 10
Trunk outlets For loop-through of the DCN trunk-line without regenerating the digital signal.Power handling capacity maximum: - 60 PCF per outlet- 90 PCF total for the three outlets of the CCU.
PCF = 60 max.
PCF = 90 max.
Central Control Unit LBB3500/05 (Trunk Outlets)
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 11
1. Mains socket with built-in fuse
Nominal
Mains voltage Mains fuse Power Consumption
220, 230, 240 V AC. T- 2A (slow blow) 175 W
105, 115 V, 125 V AC. T- 4A (slow blow)
Warning:
All units must be powered via an earthed mains outlet.
11
115V-T4A/230V-T2A
Central Control Unit LBB3500/05
I&O Manual
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 12
Extension Power Supply LBB4106/x0
1
3 4
2
Rear view
1. Trunk line cable 2. Overload indicators3. Trunk outlets4. Mains socket
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 13
Extension Power Supply LBB4106/x0
(Trunk outlet / Tap-off ’s)
1 2 31 2 3
Trunk Tap-off 1.Red LED overload indicators
2.Trunk outlet used for loop-through of the trunk-line-cable
3.Tap-off outlets are used for trunk-cable splitting
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 14
Extension Power Supply LBB4106/x0(Trunk outlet / Tap-off ’s)
Trunk outlet
For loop-through of the DCN trunk-line without regenerating the digital signal.Power handling capacity maximum: - 60 PCF per outlet- 180 PCF total for the three outlets of the EPS.Tap- offsFor Trunk-cable splitting with regenerating the digital signal.Power handling capacity maximum- 60 PCF per outlet- 180 PCF total for the three outlets of the EPS.
PCF = 60 max.
PCF = 180 max.
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 15
1. Mains socket with built-in fuse
Nominal
Mains voltage Mains fuse Power Consumption
220, 230, 240 V AC. T- 4A (slow blow) 350 W
105, 115 V, 125 V AC. T- 5A (slow blow)
Warning:
All units must be powered via an earthed mains outlet.
11
115V-T4A/230V-T2A
Extension Power Supply LBB4106/x0
I&O Manual
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 16
Audio Media Interface LBB3508/00
2
1
5 63
4
Rear view 1. Cinch Audio output sockets2. XLR Audio output sockets3. Trunk line cable 4. Overload indicators5. Trunk outlets6. Mains socket
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 17
Audio Media Interface LBB3508/00 (Audio outputs)
1 2
Output 1 Output 2 Output 3 Output 41. 4 Asymmetrical Audio output connectors
(Cinch-type)
2. 4 Symmetrical (transformer balanced) Audio output sockets
(3-pin XLR)
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 18
Audio Media Interface LBB3508/00 (Audio outputs Levels)
4 Asymmetrical audio output Nom. Max. . Interpreter floor & language -10 dBV - 10 dBV Multiple floor and line output -19 dBV +11 dBV Delegate loudspeaker channel -10 dBV + 2 dBV
4 Symmetrical Audio output Nom. Max. . Interpreter floor & language +1 dBV + 1 dBV Multiple floor and line output - 8 dBV +22 dBV Delegate loudspeaker channel +1 dBV +13 dBV
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 19
Audio Media Interface LBB3508/00 (Trunk outlet / Tap-off ’s)
1 2 3
Trunk Tap-off 1.Red LED overload indicators
2.Trunk outlet used for loop-through of the trunk-line-cable
3.Tap-off outlets are used for trunk-cable splitting
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 20
Audio Media Interface LBB3508/00 (Audio outputs)
Trunk outlet
For loop-through of the DCN trunk-line without regenerating the digital signal.Power handling capacity maximum: - 60 PCF per outlet- 90 PCF total for the three outlets of the AMI.
Tap- offs
For Trunk-cable splitting with regenerating the digital signal.Power handling capacity maximum- 60 PCF per outlet- 90 PCF total for the three outlets of the AMI.
PCF = 90 max.
PCF = 60 max.
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 21
1. Mains socket with built-in fuse
Nominal
Mains voltage Mains fuse Power Consumption
220, 230, 240 V AC. T- 2A (slow blow) 175 W
105, 115 V, 125 V AC. T- 4A (slow blow)
Warning:
All units must be powered via an earthed mains outlet.
11
115V-T4A/230V-T2A
Audio Media Interface LBB3508/00
I&O Manual
Security Systems BU Communication Systems
DCN SA PO CCE01.Nov.06 ST/SEU-CO 22
Central Control Equipment
End of section
Robert Bosch GmbH
All rights are reserved. Reproduction or passing on to
third parties in whole or in parts is prohibited without the
written consent of the copyright owner.