+ All Categories
Home > Documents > Sentry Digital Video Recorder...- Remove any DVR Device Driver associated by BT878 : select to...

Sentry Digital Video Recorder...- Remove any DVR Device Driver associated by BT878 : select to...

Date post: 26-Jan-2021
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
26
D D i i g g i i t t a a l l V V i i d d e e o o R R e e c c o o r r d d e e r r T T E E C C H H N N I I C C A A L L M M A A N N U U A A L L 2005-5 Edition Copyright 2005 by X-Vision
Transcript
  • DDiiggiittaall VViiddeeoo RReeccoorrddeerr

    TTEECCHHNNIICCAALL MMAANNUUAALL 2005-5 Edition

    Copyright 2005 by X-Vision

  • 2

    Chapter 1 Setup Introduction

    X-Vision

  • 3

    1.1 System Specification Recommendation

    The below is the recommended computer specification to work with X-Vision boards.

    Model XP4SW25 XP16SW50 – XP16SW100 XP16SW200- XP32SW200 CPU Pentium Celeron 1.7GHz or above Pentium IV 2.0Ghz or above Motherboard Intel 865 Chipset Motherboard or above

    (Aopen AX4SPE-N VALUE is recommended for over 200fps DVR)

    OS Win 2000/XP Memory 256 Mbyte or above 512 Mbyte HDD 80G or above VGA ATI Expert 2000 Pro / Geforce 2 MX200 with video ram 32M or above 64M Power 110/220V 300W 350W

    X-Vision

  • 4

    1.2 Important Notes Before Running PCDVR Server Program

    Before Operating PCDVR Server Program

    1) Recycle Bin Setup

    Check on the box “Do not move files to the Recycle Bin. Remove files immediately when deleted.” in the property of

    Recycle Bin.

    2) Display Setup

    - Set resolution at 1024x768 and High Color 16bit.

    - Set “System Standby”, “Turn off monitor” and “Turn off hard disk” at “Never” in Display Properties\Power Management

    Properties\Power Schemes.

    3) Rebooting Setup

    We highly recommend you to set automatic daily rebooting in idle time for most stable system operation.

    4) Operating System

    As PCDVR Server Software was built on Windows 2000 platform, it operates most stable on Windows 2000 platform.

    5) DirectX

    DirectX Verison 8.1b or above

    X-Vision

  • 5

    Chapter 2 DVR Hardware

    X-Vision

  • 6

    2.1 DVR Line-up

    Prodcut Line-up

    Model Camera Display / Recording Audio D/I D/O XP4SW25 4Ch 25fps / 25fps 1 4 4

    XP16SW50 16Ch 50fps / 50fps 1 8 8 XP16SW100 16Ch 100fps / 100fps 4 8 8 XP16SW200 16Ch 200fps / 200fps 8 8 8 XP32SW200 32Ch 200fps / 200fps 8 16 16

    X-Vision

  • 7

    2.2 XP4SW25

    Formation : XP4SW25 board

    Camera Input 1

    Camera Input 2

    Camera Input 4

    TV Out

    Camera Input 3

    Watchdog Terminal

    DI/DO Terminal

    X-Vision

  • 8

    2.3 XP16SW50

    Formation : XP16SW50 board + 16-Ch BNC Cable

    TV Out Impedence Jumper Arrangment Impedence : match the impedence value of video signalto the analog TV monitor property. (Default)

    Remarks

    Two pcs of XP16SW50 cards can be installed in one system to get 32-ch camera inputs same as XP32SW200.

    To PC Reset Switch

    To Motherboard Reset Terminal

    Audio Input Terminal

    TV Out

    Camera Input Terminal For Back Panel Connetion DI/DO Terminal

    16-Ch BNC Cable

    NC : no impedence matching from capture card.

    Watchdog Cable Connection

    X-Vision

  • 9

    2.4 XP16SW100

    Formation : XP16SW100 + 16-Ch BNC Cable

    Camera Input Terminal For Back Panel Connetion DI/DO Terminal

    Watchdog Cable Connection

    To PC Reset Switch

    To Motherboard Reset Terminal

    Audio Card Connect Terminal

    16-Ch BNC Cable

    TV Out

    TV Out Impedence Jumper Arrangment

    Impedence : match the impedence value of video signal to the analog TV monitor property. (Default)

    NC : no impedence matching from capture card.

    X-Vision

  • 10

    2.5 XP16SW200 (16ch)

    Formation : XP16SW200 board + 16-Ch BNC Cable

    To Motherboard Reset Terminal

    To PC Reset Switch

    Watchdog Cable Connection

    TV Out

    DI/DO Terminal

    Audio Card Connect Terminal

    16-Ch BNC Cable

    Camera Input Terminal For Back Panel Connetion

    TV Out Impedence Jumper Arrangment

    NC : no impedence matching from capture card.

    Impedence : match the impedence value of video signal to the analog TV monitor property. (Default)

    X-Vision

  • 11

    2.6 XP32SW200 (32ch)

    Formation : 2 x XP16SW100 + 2 x 16-Ch BNC Cable

    TV Out

    DI/DO Terminal

    Audio Card Connect Terminal

    (Nearest to CPU)

    16-Ch BNC Cable

    To Motherboard Reset Terminal

    To PC Reset Switch

    Watchdog Cable Connection

    DI/DO Terminal

    Audio Card Connect Terminal

    Ch 1-4,9-12,17-20,25-28

    TV Out Jump Cabling AV In AV Out

    To AV In of 2016 #2

    TV Out Impedence Jumper Arrangment

    Impedence : match the impedence value of video signal to the analog TV monitor property. (Default)

    Ch 5-8,13-16,21-24,29-32 16-Ch BNC Cable

    NC : no impedence matching from capture card.

    X-Vision

  • 12

    2.7 Audio Board (4ch)

    Formation : XP16SW100 + Audio board (4ch) + Audio input guide + Flat cable

    60 Pin Connection

    Audio In 1-4

    < 4ch Audio Board >

    PCI Slot

    4-ch Audio Board

    Capture Board

    X-Vision

  • 13

    Formation : XP16SW200 + Audio board (4ch) + Audio input guide + Flat cable

    60 Pin Connection

    Audio In 1-8

    RCA-to- D-Sub Input Cable

    PCI Slot

    2.8 Audio Board (8ch)

    X-Vision

  • 14

    2.9 Audio board (2ch)

    Formation : XP16SW50 board + Audio input guide + Flat cable

    X-Vision

  • 15

    2.10 Audio board (1ch)

    Formation : XP4SW25 board + Audio input guide + AV cable

    X-Vision

  • 16

    2.11 I/O Card

    Alarm Output

    Sensor Input

    To Serial Port on PC

    To DI/DO Terminal on capture board

    PTZ Signal Cable RS422/485

    .AC 125V, 500mA or below

    .DC 110V, 0.3A or below

    .DC 30V, 1A or below

    3 D/O Voltage

    - Control Output : DO Terminal Close

    - Normal : DO Terminal Open

    2. Operation

    Connect both power lines to DO terminal

    1. Connection

    [ Alarm Output Terminal ]

    Close 3. At normal close mode, it works reversely.

    - Sensor Detection : 1-4 Terminal & COM Port

    - Normal : 1-4 Terminal & COM Port Open

    2. Operation

    Connect one signal line to COM port and connect

    Another signal line to the desired sensor number.

    1. Connection

    [ Sensor Input Terminal ]

    Notes ;

    - N/O : Normal Open

    - N/C : Normal Close

    - DI Operation Mode (N/O or N/C) can be selected from Setup Mode of Sentry Program

    - D/O Delay Time can be adjusted from Setup Mode of Sentry Program

    X-Vision

  • 17

    2.12 Pan/Tilt Connection to DVR

    In order to control PTZ function from DVR, connect the converter which can convert RS232C to RS422/485 singal to

    COM port of DVR. Then connect signal line from receiver to convertor. Select the correct protocol type from PCDVR

    Server program and match the address number of each PTZ camera to each one in PTZ setup in PCDVR Server

    Program.

    RS422/485 Converter

    COM Port (RS232C)

    X-Vision

  • 18

    Chapter 3 DVR Software

    X-Vision

  • 19

    3.1 Driver Installation

    1. Simply run “DVRDriverSetup.exe” in “Driver-2005-00-00” folder in CD-Rom provided.

    2. Then DVR Device Driver Setup program will come out as shown below. Select one installation option.

    - Install DVR Device Driver : select when installing to a new computer after the new capture card assembly

    - Remove & Install DVR Device Driver : select when reinstalling to the existing device driver with the latest driver

    - Remove DVR Device Driver : select to delete all DVR device driver of our capture card

    - Remove any DVR Device Driver associated by BT878 : select to delete all device drivers relating BT878

    (Usable when other brands capture using BT878 was installed previously)

    3. Press OK. Then the system will reboot after completion.

    Device Manager View After Driver Installation

    X-Vision

  • 20

    3.2 DVR Program Installation

    1. Run “Setup.exe” in the folder in the CD-Rom provided.

    2. Click “Next”

    X-Vision

  • 21

    3. Specify the destination to install and click “Next”

    4. Check on three options and click “Next”

    5. Select the video type and click “Next”

    X-Vision

  • 22

    6. Now installation is being performed

    7. . Now the installation has been finished. Click “Finish” to finalize.

    X-Vision

  • 23

    8. Then double click “PCDVR” icon on the desktop to run the program. And the board type selection menu will come up.

    Check on suitable board type from the list and click “OK”

    9. Then “Recording Drive Setup” will come out. Select a drive available and select the recording type, “record or backup”.

    Then click “Apply” and OK”.

    X-Vision

  • 24

    3.3 Folders Created After DVR Program Installation

    The below folders are created after DVR Program installation.

    Folder Name Description

    Language Language files exist

    LogFile System Log files exist

    PanTilt PTZ Driver files exist

    Skin GUI skin file exists

    Sound Sound files (*.wav) used in DVR program exist

    Tools Utilities exist (Backup, Backup Player & CaptureClear)

    Update Temp folder for download when real-tim update

    WebPages Web files for web service exists

    X-Vision

  • 25

    3.4 PCDVR Server Program Image Files

    There are a few image files used in PCDVR Server Program. The files can be replaced with the ones that the users

    desire to have.

    File Name Description Size Format Path

    Logo.bmp Shown on blank channel where no camera input exists from main GUI

    320 X 240 BMP C:\PCDVR\Image

    MiniLogo.bmp Shown on main GUI to display supplier’s logo

    98 X 50 BMP C:\PCDVR\Image

    Splash.bmp Shown when loading Sentry DVR Program 500 X 200 BMP C:\PCDVR\Image

    WallPaper.bmp Wallpaper when used on DVR mode 1024 X 768 BMP C:\PCDVR\Image

    Playbacklogo.bmp Shown on blank channel where no camera input exists from playback GUI

    320 X 240 BMP C:\PCDVR\Image

    Disconnect.bmp Shown when no video signal 320 X 240 BMP C:\PCDVR\Image

    Note - You can make image files and copy them to image folder. - In order to apply customized images from install stage, you can make image folder in installation folder (ex ; Server-2003XXXX) and copy the image files to the folder.

    X-Vision

  • 26

    3.5 Language Alternation

    You can customize the language used in PCDVR Server Program Setup by editing lanuage file in C:\PCDVR\Language

    folder. Normally the initial language is English after the installation.

    Procedure

    1. Go to “C:\PCDVR\Language”.

    2. Open “Lang.ENU.ini”.

    3. Its content is ;

    [SYSTEM]

    MainColor = 166 184 206 (basic color)

    TextColor = 0 0 0 (font color)

    EditColor = 0 0 0

    EditTextColor = 0 255 0

    FontName = Verdana (Font)

    FontSize=14 (Font Size)

    FontStyle = 700 (Font Type Bold:700, Normal:400)

    [MESSAGE] Language change starts below this line. Input the term with your language on the right to “= “mark

    cancel = cancel

    yes = yes Ex ) yes = si (when changing from English to Italian)

    X-Vision

    Digital Video Recorder


Recommended