Setup Reference guide for KX-NS1000 Version 4.22 Firmware M-NetSIP Trunk service (with Built-in Router) Version 1.0(PSCEU) 18.November, 2015
Transcript
Page 1: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

Setup Reference guide for KX-NS1000

Version 4.22 Firmware

“M-Net” SIP Trunk service

(with Built-in Router)

Version 1.0(PSCEU) 18.November, 2015

Page 2: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

2

SUMMARY

This document is a reference for configuring “M-Net” SIP trunks with Panasonic KX-NS1000 systems

and includes the settings required for Incoming Call DDI routing and Outgoing Call CLI presentation.

SIP trunk details such as account ID, authentication ID, password and DDI number will be provided

by M-Net.

Attention:

This document was created based on the results of test environment accounts.

Panasonic cannot guarantee SIP Trunk operation in all environments, however as a result of

completing this Inter-Operability Test Panasonic will provide technical support for any issues

experienced an assist as far as possible in providing a resolution.

Please obtain relevant information from Service provider before configuration of SIP trunks.

Panasonic will not be held liable for any information provided in this guidance document.

Information used in this document is for interoperability testing.

Information and Specifications in this document are subject to change without notice.

Note

[SIP Registration]

Deactivate a "Remove all binding when INS".

[Transfer Function]

SIP Server is Not supported a REFER method; Use a FWD to CO Transfer.

[FAX]

A G.711 Inband codec is supported. T.38 is not supported.

Table of Contents

(1) Provisioning a SIP trunk: Page 3

(2) Incoming Call Routing: Page 5

(3) Outgoing Call CLI: Page 6

(4) CLIR Outgoing Call (Withholding number): Page 7

(5) Call Forward Page 8

(6) Built-in Router and WAN settings: Page 10

(7) Packet Filtering Settings : Page 12

Page 3: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

3

(1) Provisioning the SIP Trunk

SIP Trunk – Port Property

Move mouse over [V-SIPGW16] and click [Ous] and Select [Port Property]

SIP Trunk – Port Property continued

[Main] Tab

1. Channel Attribute: Basic Channel

2. Provider Name: Enter a name – reference only

3. SIP Server Location – Name: biz-int.m-call.de – (M-Net provided)

4. SIP Server Location – IP Address: Not required

5. SIP Server port Number: 5064 – (M-Net provided)

6. SIP Service Domain: Not required

7. Subscriber Number: Not required

Page 4: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

4

SIP Trunk – Port Property continued

[Account] Tab

1. User name: Enter the SIP Account (User name) as supplied by M-Net.

(Note this is user name without @biz-int.m-call.de)

For example: SIP Account (User name) = +4989123456780

Enter: +4989123456780

2. Authentication ID: Enter the Authentication ID as supplied by M-Net.

(Note this is user name with @biz-int.m-call.de)

For example: Authentication ID =

[email protected]

Enter: [email protected]

3. Authentication Password: Enter the Authentication Password as supplied by M-Net.

For example: Authentication Password = Zzzzzzzzzz

Enter: Zzzzzzzzzz

SIP Trunk – Port Property continued

[Register] Tab

1. Register Ability: Leave enabled

2. Register Interval: Leave at 3600

3. Un-Register Ability: Disable

4. Registrar Server – Name: Not required

5. Registrar Server – IP Address: Not required

6. Registrar Server port number: Leave at 5060

Page 5: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

5

(2) Incoming Call Routing

Go to [CO & Incoming call] and select [3.DDI /DID Table]

1. DDI/DID Number: Enter the DDI number in the format (as below)

Example: +49-89-12-34-56-78-0

Enter: 4989123456780

2. DDI/DID Name: Determined by the installer (optional setting)

3. DDI/DID Destination: Determined by the installer (extension number, group etc)

Page 6: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

6

(3) Outgoing Call CLI

Move mouse over [V-SIPGW16] click [Ous] Select [Port Property] and [Calling Party] Tab

From Header – User Part: PBX-CLIP

Number Format: +International

Click [OK].

Go to [4.Extension, 1.Wired Extension, 1.Extension Settings] & select [CLIP]

[CLIP] tab

Enter a valid CLI number for each required extension in the CLIP ID field

Click [OK].

Page 7: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

7

(4) CLIR Outgoing Call (Withholding Number)

There are 2 methods of CLIR Outgoing Call.

(4-1) CLIR Setting

Go to [4.Extension, 1.Wired Extension, 1.Extension Settings] & select [CLIP]

[CLIP] tab

1. CLIR: Enable

Move mouse over [V-SIPGW16] click [Ous] Select [Port Property] and [Calling Party] Tab

2. From Header – User Part: PBX-CLIP

3. Number Format: +International

(4-2) CLIR Outgoing dial with special code (*31*)

Using *31* to add in the top digit like in the following.

Make call dialed as *31* 08998765430

To: <sip:*31*[email protected]>

Page 8: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

8

(5) Call Forward

Example case

Go to [2.System, 7.Class of Service, 1.COS Settings] & select [CO & SMDR]

[CO & SMDR] tab

Call Forward to CO: Enable

Move mouse over [V-SIPGW16] Select [Port Property] and [Advanced] Tab

[Advanced] tab

Diversion Header: Disable

Call FWD

CLI Number DDI Forward Number

09999123456 07777000001 05555000002

Original

(1st Caller)

PBX

DDI

Forwarded

(Called Party)

Page 9: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

9

INVITE sip:[email protected] SIP/2.0

Via: SIP/2.0/UDP 192.168.0.101:35060;branch=z9hG4bKs4283fcd4f;rport

Max-Forwards: 70

Call-ID: [email protected]

From: <sip:[email protected]>;tag=1981099409

To: <sip:[email protected]>

CSeq: 1 INVITE

Allow: INVITE,ACK,CANCEL,BYE,PRACK,INFO,UPDATE,OPTIONS,REGISTER,NOTIFY

Supported: timer,100rel

User-Agent: Panasonic-MPR12-V004.22019/VSIPGW-V3.0000

Contact: <sip:[email protected]:35060>

Session-Expires: 1800

Content-Type: application/sdp

Content-Length: 268

Go to [4.Extension, 1.Wired Extension, 2.FWD/DND]

For example:

Select your Extension Number.

For external calls: Always (All)

Input prefix and forwarded number and #: 005555000002#

This is an example of FWD Invite packet from PBX.

Note: M-Net appends “P-Asserted-Identity” header in INVITE packet. Forwarded phone should

set to show CLIP “From header” because “P-Asserted-Identity” always included PBX DDI

CLIP.

Page 10: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

10

(6) Built-in Router and WAN Settings

NS1000 has a Built-in Router and filtering functions (Ver3.2 or later) so advanced routing

configuration can be managed by the NS1000 and the internet router/modem simply providing

internet access.

Go to [Router Configuration]->[1.Setup]->[2.WAN]->[1.Connection Settings]

Select the appropriate the Connection Type.

In this example, we use the Static IP address option.

WAN IP Address: Enter your actual IP address.

Subnet Mask: Enter the appropriate subnet mask.

Gateway: Enter the actual Gateway IP address.

Preferred DNS IP Address: Enter the actual DNS IP address.

Alternative DNS IP Address: Enter the actual Alternative DNS IP address.

Click [Apply].

Page 11: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

11

LAN Setting.

Go to [Network Service]->[1.IP Address/Ports]

Default Gateway: Blank

* Delete the “LAN Default Gateway IP address” if it’s entered IP address.

Note: NS1000 will work as the router, Not need the LAN Gateway.

DNS IP Address: Blank

* Delete the “Preferred DNS” and “Alternative DNS” if it’s entered IP address.

To use DNS address entered [Router Configuration], this field must be blank. .

Click [Apply]

Perform System Reset for changes to take effect.

Page 12: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

12

(7) Packet Filtering Settings

Go to [Router Configuration] --> [2.Firewall] --> [2.Packet Filtering]

Click [Advanced Setting]

LAN->WAN Basic Policy: [Accept]

WAN -> LAN Basic Policy: [Discard]

Entry No.: Select [1]

Filter: Select [Enable]

Page 13: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

13

Configure Filter 1, this is the setting pass through packet from M-Net server, port 35060.

Protocol Number: [Protocol Name] and choose [UDP]

TCP/UDP Source Port: /Port Number [Port Number] / [35060] -[ 35060]

TCP/UDP Destination Port /Number: [Port Number] / [35060] -[ 35060]

Source: [Address]

IP Address: [93.104.204.240] – Enter your assigned Server IP

Direction: [WAN->LAN]

Page 14: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

14

Click [Apply]

Set Filter 2, this is the setting block packet from except M-Net server port 35060.

Click [Advanced Setting]

LAN->WAN Basic Policy: [Accept]

WAN -> LAN Basic Policy: [Discard]

Entry No.: Select [2]

Filter: Select [Enable]

Page 15: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

15

Protocol Number: [Protocol Name] and choose [UDP]

TCP/UDP Source Port: [Any]

TCP/UDP Destination Port /Number: [Port Number] / [35060] -[ 35060]

Source: [Any]

Direction : [WAN->LAN]

Policy : [Discard]

Click [OK]

Go to following page.

Page 16: Setup Reference guide for KX-NS1000 Version 4.22 ......Setup Reference guide for KX-NS1000 Version 4.22 Firmware “M-Net” SIP Trunk service (with Built-in Router) Version 1.0(PSCEU)

16

Confirm the Packet Filtering Settings


Recommended