Undertaking
I, Rakesh Bhargava, Vice President (Environment) of Mis. Shree Cement Ltd. give this
undertaking to the effect that the ToRs prescribed by MoEF&CC, New Delhi vide letter no. J-
11011/343/2012-IA II (I) dated io" Feb., 2016 for "Proposed Expansion of Integrated Cement Plant -
Clinker (11.2 to 15.0 Million TPA), Cement (8 ..8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW)
along with Synthetic Gypsum Unit (1560 TPD) and DG Sets (1000 to 2000 KVA) Near Village: Ras, Tehsil:
Jaitaran, District: Pali (Rajasthan)" have been compiled with, and the data submitted are factually
correct.
Date: 29.06.2016
Place: Beawar
For & behalf of M/s. Shree Cement Ltd.
Rakesh Bhargava
Vice President (Environment)
JAIPUR OFFICE: SB-187, Bapu Nagar, Opp. Rajasthan University, JLN Marg, Jaipur-302 015
Phone: 0141 4241200,4241204, Fax: 0141 4241219
NEW DELHI OFFICE: 122-123, Hans Bhawan,1, Bhadurshah Zafar Marg, New Delhi 110002
Phone: 01123370828,23379218,23370776, Fax: 011 23370499
CORP. OFFICE: 21, Strand Road, Kolkata 700 001 Phone: 033-22309601-4 Fax: 033 22434226
i
CONTENTS
S. NO. PARTICULARS PAGE NO.
A. TOR LETTER & TOR COMPLIANCE 1 - 27
1. ToR Letter 1 - 11
2. ToR Compliance 12 - 27
B. FINALEIA / EMP REPORT 28 - 246
Chapter - I Introduction 28-42
Chapter - II Project Description 43 - 63
Chapter - III Description of the Environment 64-117
Chapter - IV Anticipated Environmental Impacts and Mitigation Measures 118-143
Chapter - V Analysis of Alternatives (Technology & Site) 144
Chapter - VI Environmental Monitoring Programme 145-150
Chapter - VII Additional Studies 151-183
Chapter - VIII Project Benefits 184-197
Chapter - IX Environmental Cost Benefit Analysis 198
Chapter - X Environmental Management Plan 199-234
Chapter - XI Summary & Conclusion 235-244
Chapter - XII Disclosure of Consultant Engaged 245-246
C. ANNEXURES 247 - 477
i
CONTENTS
S. NO. PARTICULARS PAGE NO.
A. TOR LETTER & TOR COMPLIANCE 1 - 27
1. ToR Letter 1 - 11
2. ToR Compliance 12 - 27
B. FINALEIA / EMP REPORT 28 - 246
Chapter - I Introduction 28-42
Chapter - II Project Description 43 - 63
Chapter - III Description of the Environment 64-117
Chapter - IV Anticipated Environmental Impacts and Mitigation Measures 118-143
Chapter - V Analysis of Alternatives (Technology & Site) 144
Chapter - VI Environmental Monitoring Programme 145-150
Chapter - VII Additional Studies 151-183
Chapter - VIII Project Benefits 184-197
Chapter - IX Environmental Cost Benefit Analysis 198
Chapter - X Environmental Management Plan 199-234
Chapter - XI Summary & Conclusion 235-244
Chapter - XII Disclosure of Consultant Engaged 245-246
C. ANNEXURES 247 - 477
i
CONTENTS
S. NO. PARTICULARS PAGE NO.
A. TOR LETTER & TOR COMPLIANCE 1 - 27
1. ToR Letter 1 - 11
2. ToR Compliance 12 - 27
B. FINALEIA / EMP REPORT 28 - 246
Chapter - I Introduction 28-42
Chapter - II Project Description 43 - 63
Chapter - III Description of the Environment 64-117
Chapter - IV Anticipated Environmental Impacts and Mitigation Measures 118-143
Chapter - V Analysis of Alternatives (Technology & Site) 144
Chapter - VI Environmental Monitoring Programme 145-150
Chapter - VII Additional Studies 151-183
Chapter - VIII Project Benefits 184-197
Chapter - IX Environmental Cost Benefit Analysis 198
Chapter - X Environmental Management Plan 199-234
Chapter - XI Summary & Conclusion 235-244
Chapter - XII Disclosure of Consultant Engaged 245-246
C. ANNEXURES 247 - 477
ii
INDEX
S.NO. PARTICULARS PAGE NO.
Chapter- I Introduction 28 - 42
1.1 Purpose of the report 28
1.2 Identification of the project and project proponent 28
1.2.1 Introduction of the projectproponent 28
1.2.2 Identification of the project 29
1.3 Brief Description of nature, size, location of the project and its importance to the country, region 34
1.3.1 Brief Description of nature, size and location of project 34
1.3.2 Location Map 36
1.3.3 Site Selection 40
1.3.4 Approach to the Plant site 41
1.3.5 Importance to the country and region 41
1.4 Scope of study 42
Chapter - II Project Description 43-63
2.1 Type of the project 43
2.2 Need for the project 43
2.3 Location 44
2.4 Requirements for the project 44
2.4.1 Raw Material Requirement 44
2.4.2 Fuel Requirement 44
2.4.3 Other Basic Requirements 46
2.4.3.1 Water Requirement 46
2.4.3.2 Power Requirement 59
2.4.3.3 Man Power Requirement 50
2.5 Land Details 50
2.5.1 Plant Layout 51
2.6 Manufacturing Process description 53
2.6.1 Cement Plant 53
2.6.2 Waste heat Recovery Power Plant (90MW) 56
2.6.3 Synthetic Gypsum Plant 57
2.6.4 Equipment Details 60
2.6.4.1 Equipment Selection 60
2.6.4.2 Plant and Equipment Sizing 60
2.6.5 Storage facilities 60
2.6.6 Infrastructure facilities 61
2.7 Township / Residential Colony 61
Chapter - III Description of the Environment 64-117
3.1 Introduction 64
3.2 Study Area at a glance 64
3.3 Baseline Data Collection 64
3.3.1 Primary Data 64
3.3.2 Instruments used for environmental baseline data collection 65
3.4 Land Use/Land Cover Study 66
3.4.1 Objective 66
3.4.2 Data Used 66
3.4.2.1 Base Map of the Study Area 67
3.4.3 Methodology 68
3.4.4 Details of LULC 68
3.4.4.1 Land Use & Land Cover Classes 68
3.4.4.2 Generation and analysis of data 69
3.4.4.2.1 Land Use / Land Cover Details of Core Zone 71
3.4.4.2.2 Land Use / Land Cover Details of Buffer Zone 73
iii
S.NO. PARTICULARS PAGE NO.
3.4.5 Observation of the LULC Data 75
3.4.6 Identification of Impacts on land Use Pattern due to project Activity 75
3.4.7 Recommendations 75
3.4.8 Conclusion 76
3.4.9 Digital Elevation Model 76
3.4.9.1 Data Used 76
3.4.9.2 Methodology 76
3.4.9.3 Interpretation 77
3.5 Seismicity and Flood Hazard Zonation of the area 80
3.5.1 Seismicity of the area 80
3.5.2 Flood Hazard Zonation of the Area 82
3.6 Climate and Rainfall 83
3.7 Meteorology 84
3.7.1 Micro-Meteorology at site 84
3.8 Ambient Air Environment 86
3.8.1 Mineralogical Composition For RSPM 93
3.9 Noise Environment 94
3.10 Water Environment 97
3.10.1 Surface Water 97
3.10.2 Ground Water Quality 97
3.11 Soil Environment 101
3.11.1 Soil Quality and Characteristics 101
3.12 Biological Environment 104
3.12.1 Introduction 104
3.12.2 Ecological Sensitive Area 104
3.12.3 Flora 104
3.12.4 Fauna 107
3.13 Socio-Economic Environment 109
3.13.1 Objectives of the study 109
3.13.2 Scope of work 109
3.13.3 Methodology 109
3.13.4 Background Information of the Area 110
3.13.5 Baseline Data & Analysis 110
3.13.6 Demographic Profile of the Study Area 110
3.13.6.1 Demographic Profile 113
3.13.6.2 Vulnerable Group 113
3.13.6.3 Literacy Rate 114
3.13.6.4 Economic Activities 115
3.13.7 Conclusion 117
3.14 Industries Falling Within 10 Km Radius of the Area 117
3.15 Conclusion 117
Chapter - IV Anticipated Environmental Impacts and Mitigation Measures 118- 143
4.1 Environmental Impact study 118
4.2 Impact due to proposed Expansion activity 118
4.3 Anticipated Impacts during Construction Phase 118
4.3.1 Impact on Topography and Land Use 118
4.3.2 Impact on Air Quality 119
4.3.3 Impact on Noise Levels 119
4.3.4 Impact on Water Resources and Water Quality 119
4.3.5 Impact on Soil 120
4.3.6 Impact on Terrestrial Ecology 120
4.4 Anticipated Impacts during Operation phase and Proposed Mitigation Measures 120
4.4.1 Impact on Land Use Pattern 120
4.4.2 Impact on Air Quality and Mitigation Measures 121
iv
S.NO. PARTICULARS PAGE NO.
4.4.2.1 Impact due to operation of proposed Expansion project 121
4.4.2.2 Air Quality Predictions through Mathematical Modeling 122
4.4.2.2.1 Air Pollution Modeling 122
4.4.2.2.2 Pollutants/Model Options Considered for computations 122
4.4.2.2.3 Model Options used for Computations 123
4.4.2.2.4 Model Input Data 123
4.4.2.2.5 Modeling Procedure 124
4.4.2.2.6 Gaussian Plume Model 125
4.4.2.2.7 Extrapolation of Wind Speed 125
4.4.2.2.8 Stability Classification 125
4.4.2.2.9 Dispersion Parameters 125
4.4.2.2.10 Mixing Height 126
4.4.2.2.11 Presentation of Results 126
4.4.2.3 Impact due to Transportation of Raw Material and Finished Product 131
4.4.3 Impact on Noise Level and Mitigation Measures 136
4.4.4 Impact on Water Quality and Mitigation Measures 136
4.4.5 Impact on Soil and Mitigation Measures 136
4.4.6 Impact due to Solid and Hazardous Waste Generation 137
4.4.7 Impact on Biological Environment 137
4.4.8 Impact on Socio-Economic Environment 138
4.4.9 Impact on Occupational Health and Mitigation Measures 139
4.5 Summary and Conclusion 141
Chapter - V Analysis of Alternatives (Technology and Site) 144
5.1 Analysis of Alternatives 144
Chapter - VI Environmental Monitoring Programme 145 - 150
6.1 Introduction 145
6.2 Formation of Environmental Management Cell (EMC) 145
6.2.1 Structure of EMC 145
6.2.2 Responsibilities of EMC 146
6.3 Measurement Methodologies 146
6.3.1 Instruments to be used 146
6.3.2 Monitoring Programme 147
6.3.3 Monitoring Schedule 147
6.3.4 Methodology adopted 147
6.4 Locations of Monitoring Stations 149
6.5 Data Analysis 150
6.6 Detailed Budget 150
CHAPTER- VII ADDITIONAL STUDIES 151-183
7.1 Introduction 151
7.2 Public Consultation 151
7.2.1 Public Hearing Proceedings 151
7.2.2Public Hearing Notice published in Newspapers Dainik Bhaskar and Dainik Navjyoti dated
18thMarch, 2016152
7.2.3 Photographs of Public Hearing 152
7.2.4 Action Plan for the issues raised during Public Hearing 153
7.3 Hydro-Geological Study & Rainwater Harvesting Plan 159
7.4 Risk Assessment and Disaster Management Plan 159
7.4.1 Risk Assessment & Damage Control 159
7.4.2 Hazard Identification & Risk Assessment (HIRA) for Integrated Cement Project 159
7.4.3 Measures for Occupational Health Hazards 165
7.4.4 Disaster Management Plan 166
7.4.4.1 On-site emergency planning 171
v
S.NO. PARTICULARS PAGE NO.
7.4.4.2 Emergency Communications 176
7.4.4.3 Special Emergency Equipment 181
7.4.5 Conclusion 183
Chapter - VIII Project Benefits 184-197
8.1 Introduction 184
8.2 Promotion of Social and Economic status 184
8.3 ESC Activities Carried Out by Shree CementLtd. 185
8.3.1 Primary Education Programmes 185
8.3.2 Promoting Gender Equality andWomen Empowerment Programmes 188
8.3.3 Agriculture Development programmes 188
8.3.4 Reducing Child Mortality and Improving Health 190
8.3.5 Ensuring Environment Sustainability 191
8.3.6 Social Business Projects 191
8.3.7 Employment Enhancing Vocational Skills 193
8.4 Conclusion 197
Chapter -IX Environmental Cost Benefit Analysis 198
9.1 Environmental Cost Benefit Analysis 198
Chapter - X Environmental Management Plan 199-234
10.1 Introduction 199
10.2 Air Quality Management 200
10.2.1 Stack Emissions and Control Technologies 200
10.2.2 Fugitive Emissions, Sources and Control Technologies 201
10.2.2.1 Fugitive Emissions 201
10.2.2.2 Sources of Fugitive Emissions in Cement Plant and Mitigation Measures 202
10.3 Noise Management 210
10.4 Water Management 210
10.4.1 Water Requirement 210
10.4.2 Water Management 211
10.4.2.1 Sewage Treatment Plant 211
10.4.3 Water Conservation 212
10.4.3.1 Rain Water Harvesting at Plant and Colony 212
10.5 Waste Management 214
10.5.1 Solid Waste Management 214
10.5.2 Hazardous Waste Managements 214
10.6Concept of Waste Minimization, 3 R s (Reuse, Recycle and Recover Techniques), Energy and
Natural Resource Conservation Measures216
10.6.1 Waste Minimization - 3R s 216
10.6.1.1 Reuse 216
10.6.1.2 Recycle 216
10.6.1.3 Recovery 216
10.6.2 Energy Conservation 216
10.6.3 Natural Resource Conservation 217
10.7 Greenbelt Development and Plantation Programme 217
10.7.1 GreenbeltPlantation at Plant Site 218
10.7.2 Objective 218
10.7.3 Plantation Programme 218
10.7.4 Photographs showing Existing Green Belt Development 220
10.7.5 Guidelines for Green Belt Development 221
10.8 Occupational Health and Safety Measures 222
10.8.1 Health and Safety Policy 222
10.8.2 Occupational Health and Safety Hazards 222
10.8.3 Occupational Health Surveillance 225
vi
S.NO. PARTICULARS PAGE NO.
10.8.4 Implementation of OHS standards as per OSHAS/USEPA 229
10.8.5 Safety Committee 230
10.8.6 Medical Facilities 230
10.8.7 Investigation Facility 230
10.8.8 Facility for Minor Surgical Operation 230
10.8.9 Ambulance Services 230
10.8.10 First Aid Boxes 230
10.8.11 Plan and Fund allocation for Occupational and Safety Hazards 231
10.9 Corporate Environment Policy 231
10.10 Vehicular Pollution Control and its Management 231
10.11 Compliance of CREP Recommendations 233
10.12 Conclusion 234
Chapter - XI Summary & Conclusion 235-244
11.1 Introduction 235
11.2 Justification for the project 235
11.3 Details about the Project 236
11.3.1 Brief Description of the Project 236
11.3.2 Requirements for the Project 237
11.3.2.1 Raw Material Requirement for the Project 237
11.3.2.2 Fuel Requirement 238
11.3.2.3 Other Basic Requirement 238
11.4 Process Description 239
11.4.1 New Clinker Unit (Unit-XI) and Cement Unit Manufacturing Process 239
11.4.2 Waste Heat Recovery Power Plant 239
11.5 Description of Environment 239
11.5.1 Presentation of Results (Air, Noise, Water and Soil) 239
11.5.2 Biological Environment 240
11.5.3 Socio-Economic Environment 240
11.6 Anticipated Environmental Impacts and Mitigation Measures 240
11.7 Environmental Monitoring Programme 242
11.8 Additional Studies 242
11.9 Public Consultation 242
11.10 Risk Assessment and Disaster Management Plan 242
11.11 Project Benefits 242
11.12 Environment Management Plan 243
11.13 Occupational Health and Safety 244
11.14 Conclusion 244
Chapter - XII Disclosure of Consultant Engaged 245-246
12.1 Disclosure of the Consultant Engaged 245
vi
S.NO. PARTICULARS PAGE NO.
10.8.4 Implementation of OHS standards as per OSHAS/USEPA 229
10.8.5 Safety Committee 230
10.8.6 Medical Facilities 230
10.8.7 Investigation Facility 230
10.8.8 Facility for Minor Surgical Operation 230
10.8.9 Ambulance Services 230
10.8.10 First Aid Boxes 230
10.8.11 Plan and Fund allocation for Occupational and Safety Hazards 231
10.9 Corporate Environment Policy 231
10.10 Vehicular Pollution Control and its Management 231
10.11 Compliance of CREP Recommendations 233
10.12 Conclusion 234
Chapter - XI Summary & Conclusion 235-244
11.1 Introduction 235
11.2 Justification for the project 235
11.3 Details about the Project 236
11.3.1 Brief Description of the Project 236
11.3.2 Requirements for the Project 237
11.3.2.1 Raw Material Requirement for the Project 237
11.3.2.2 Fuel Requirement 238
11.3.2.3 Other Basic Requirement 238
11.4 Process Description 239
11.4.1 New Clinker Unit (Unit-XI) and Cement Unit Manufacturing Process 239
11.4.2 Waste Heat Recovery Power Plant 239
11.5 Description of Environment 239
11.5.1 Presentation of Results (Air, Noise, Water and Soil) 239
11.5.2 Biological Environment 240
11.5.3 Socio-Economic Environment 240
11.6 Anticipated Environmental Impacts and Mitigation Measures 240
11.7 Environmental Monitoring Programme 242
11.8 Additional Studies 242
11.9 Public Consultation 242
11.10 Risk Assessment and Disaster Management Plan 242
11.11 Project Benefits 242
11.12 Environment Management Plan 243
11.13 Occupational Health and Safety 244
11.14 Conclusion 244
Chapter - XII Disclosure of Consultant Engaged 245-246
12.1 Disclosure of the Consultant Engaged 245
vi
S.NO. PARTICULARS PAGE NO.
10.8.4 Implementation of OHS standards as per OSHAS/USEPA 229
10.8.5 Safety Committee 230
10.8.6 Medical Facilities 230
10.8.7 Investigation Facility 230
10.8.8 Facility for Minor Surgical Operation 230
10.8.9 Ambulance Services 230
10.8.10 First Aid Boxes 230
10.8.11 Plan and Fund allocation for Occupational and Safety Hazards 231
10.9 Corporate Environment Policy 231
10.10 Vehicular Pollution Control and its Management 231
10.11 Compliance of CREP Recommendations 233
10.12 Conclusion 234
Chapter - XI Summary & Conclusion 235-244
11.1 Introduction 235
11.2 Justification for the project 235
11.3 Details about the Project 236
11.3.1 Brief Description of the Project 236
11.3.2 Requirements for the Project 237
11.3.2.1 Raw Material Requirement for the Project 237
11.3.2.2 Fuel Requirement 238
11.3.2.3 Other Basic Requirement 238
11.4 Process Description 239
11.4.1 New Clinker Unit (Unit-XI) and Cement Unit Manufacturing Process 239
11.4.2 Waste Heat Recovery Power Plant 239
11.5 Description of Environment 239
11.5.1 Presentation of Results (Air, Noise, Water and Soil) 239
11.5.2 Biological Environment 240
11.5.3 Socio-Economic Environment 240
11.6 Anticipated Environmental Impacts and Mitigation Measures 240
11.7 Environmental Monitoring Programme 242
11.8 Additional Studies 242
11.9 Public Consultation 242
11.10 Risk Assessment and Disaster Management Plan 242
11.11 Project Benefits 242
11.12 Environment Management Plan 243
11.13 Occupational Health and Safety 244
11.14 Conclusion 244
Chapter - XII Disclosure of Consultant Engaged 245-246
12.1 Disclosure of the Consultant Engaged 245
vii
LIST OF TABLES
TABLE NO. PARTICULARS PAGE NO.
1.1 Existing Clearances / Consents at Ras Plant of SCL 30
1.2 Project Proposal 31
1.3 Time of Completion of the Project 32
1.4 Brief Description of Nature, Size and Location of Project 34
2.1 Raw Material Requirement for Clinkerization and CPP 43
2.2 Raw Materials Requirement for Synthetic Gypsum Unit 43
2.3 Fuel Requirement 45
2.4 Basic Requirements for the Project 46
2.5 Break-up of Water Requirement 46
2.6 Power Requirement 49
2.7 Manpower Requirement 50
2.8 Area Details 50
2.9 Plant and Equipment Sizing 60
2.10 Storage Facilities 61
3.1 Primary Data Collection 65
3.2 Land Use/Land Cover Details of core zone 71
3.3 Land Use/Land Cover Details of study area 73
3.4 Seismic Zones in India 80
3.5 Rainfall Data For last 10 Years 83
3.6 Micro- Meteorology at Site 84
3.7 Locations of Ambient Air Quality Monitoring Stations 87
3.8 Ambient Air Quality Monitoring Results 89
3.9 NAAQS Prescribed by CPCB 92
3.10 Chemical Characterization of RSPM 93
3.11 Locations of Noise Monitoring Stations 94
3.12 Ambient Noise Level Monitoring Results 95
3.13 CPCB Noise Standards 95
3.14 Locations of Ground Water Sampling Stations 97
3.15 Ground Water Analysis 99
3.16 Locations of Soil Sampling Stations 101
3.17 Soil Analysis 102
3.18 Standard Soil Classification 103
3.19 List of Flora in Core and Buffer Area 104
3.20 List of Fauna 107
3.21 Socio-Economic Profile of Study Area 110
3.22 Socio-Economic Profile of Study Area (Plant and Mine) 111
3.23 Demographic profile of the study area (Plant and Mine Site) 113
3.24 SC/ST Population of the Study Area 113
3.25 Literacy Level of the Study Area 114
3.26 Work Forces of the Study Area 115
4.1 Stack Emission Details 123
4.2 Emission Rate and Emission Conditions 124
4.3 Mixing Height for the plant site 126
4.4 Peak Incremental Concentration for Different Scenarios 126
4.5 Traffic Volume Count Survey 133
4.6(A) Inward Traffic due to the Raw Material Transportation 134
4.6(B) Outward Traffic due to the Finished Product Transportation 134
4.6 (C) Inward Traffic: Railways - Raw Material 135
4.6 (D) Outward Traffic: Railways - Finished Products 135
4.7 Anticipated Adverse Environmental Impacts and Mitigation 142
6.1 Frequency For Post Project Monitoring 147
6.2 Post - Project Monitoring 148
6.3 Locations for Post Project Monitoring 150
viii
TABLE NO. PARTICULARS PAGE NO.
6.4 EMP Cost Break-up 150
7.1 Possible Hazardous Locations on site 159
7.2 List of Damages Envisaged at Various Heat Loads 161
7.3 High Risk Categories and Preventive Measures 165
7.4 List of Extinguisher to be used as case specific 178
7.5 List of Extinguisher to be used as Site specific 179
7.6 Summary of Recommended Personal Protective Equipment according to hazard onsite 180
8.1 Expenditures incurred on CSR Activities 194
8.2 Proposed Expenditure on CSR activities 194
8.3 Detailed Activity- wise Action Plan For ESC Activities 195
10.1 List of Air Pollution Control Equipments 200
10.2 Emission Details 201
10.3 Storage Facilities 202
10.4 Proposed Rainwater harvesting in Plant and Colony area 213
10.5 (a) Solid Waste Generation and their End Use 214
10.5 (b) Quantity of Fly Ash Generation 214
10.6 Hazardous Waste Generation 214
10.7 Hazardous Waste Utilization 215
10.8 Hazardous Waste Utilization in 2015 - 16 215
10.9 Existing Plantation Details 219
10.10 Action Plan for Greenbelt development / Plantation 221
10.11 Fund allocation for Occupational and Safety Hazards 231
10.12 Emission Standards for Vehicles 232
10.13 Vehicle Check Sheet for Fitness Certificate 232
10.14 Compliance of Crep Recommendations 233
LIST OF FIGURES
FIGURE NO. PARTICULARS PAGE NO.
1.1 Line Diagram showing capacity of each unit along with number of units 33
1.2 Location Map 36
1.3 Map showing Corner Co-ordinates of the Plant Site 37
1.4 Google Earth Downloaded Map of the Plant Site 38
1.5 Map showing Environmental Settings of the 10 km radius study area 36
1.6 (a) Photographs of the Existing Plant 40
1.6 (b) Photograph showing site for Unit XI & Cement mill within Existing Plant Premises 41
2.1 Mass Balance Diagram 45
2.2 Water Balance Diagram 48
2.3 Plant Layout 52
2.4 Process Flow Diagram 55
2.5 Process Flow Sheet of Waste Heat Recovery boiler 56
2.6 Process Flow Sheet of Synthetic gypsum 57
3.1 Base Map of the Study Area 67
3.2 Geo-Referencing of Satellite Image using SOI Toposheet 69
3.3 Difference between original image and Radiometrically Enhanced images 70
3.4 Land Use/Land Cover Map of the core zone 72
3.5 Land Use/Land Cover Map of the buffer zone 74
3.6 Digital Elevation Model of the study with contour map 78
3.7 3D-View 79
3.8 Seismic Zone Map 81
3.9 Flood Hazard Zonation Map of the Area 82
3.10 Rainfall for last 10 years 83
3.11 Wind Rose Diagram of site 85
3.12 Key Plan showing Ambient Air Quality & Noise Monitoring Locations 88
ix
FIGURE NO. PARTICULARS PAGE NO.
3.13(A) Graph showing PM10 Concentrations (Max. &Min.) at different monitoring stations 90
3.13(B) Graph showing PM2.5 Concentrations (Max. & Min.) at different monitoring stations 90
3.13 (C) Graph showing SO2 Concentrations (Max. & Min.) at different monitoring stations 91
3.13 (D) Graph showing NOxConcentrations (Max. & Min.) at different monitoring stations 91
3.14 (A) Graph showing Noise Levels of different locations during day time 96
3.14(B) Graph showing Noise Levels of different locations during night time 96
3.15 Key Plan showing Ground Water and Soil Sampling Locations 98
3.16 Demographic Profile of the Study Area 113
3.17 SC / ST Population within 10 Km Study Area 114
3.18 Gender Wise Literacy Details 115
3.19 Working Details 116
4.1 Isopleth showing the incremental GLCs of PM10 due to Plant activities 128
4.2 Isopleth showing the incremental GLCs of SO2due to Plant activity 129
4.3 Isopleth showing the incremental GLCs of NO2 due to Plant activities 130
4.4 Isopleth showing the incremental GLCs of PMdue to Plant and Mining activities 131
4.5 Traffic Volume Count 133
6.1 Structure of EMC at Shree Cement Plant (Pali) 146
8.1 Major areas under ESC activities 185
10.1 Existing Air Pollution Control Equipments 200
10.2 Existing Storage Facilities 203
10.3 Schematic diagram of Sewage Treatment Plant 211
10.4 Photographs of Existing STP 212
10.5 Photographs showing Rain Water Harvesting 213
11.1 Brief Description of the Project 236
11.2 Raw Material Requirement, Source and Transportation for Clinkerization and CPP 237
11.3 Raw Materials Requirement for Synthetic Gypsum Unit 238
11.4 Fuel Requirement 238
11.5 Basic Requirements for the Project 239
11.6 Post Project Monitoring 242
LIST OF ANNEXURES
ANNEXURE NO. DETAILS PAGE NO.
1 (a) Environmental Clearance Letters 247 - 293
1 (b) Certified EC Compliance 294 - 307
1 (c) Status of Compliance of Consent to Operate 308 - 315
2 CGWA Permission for Ground Water 316 - 320
3 Hydro-geological Study Report 321 - 371
4 Hourly Meteorological data 372 - 382
5 Detailed Ambient Air Quality Monitoring Tables 383 - 394
6 Note on Polluted Stretch of River in Rajasthan 395 -396
7 (a) Format for OHS 397 - 398
7 (b) Sample Test Report of OHS 399 - 404
8 Corporate Environment Policy 405 - 409
9 (a) EC Letter - Nimbeti Limestone Mine 410 - 421
9 (b) ToR Letter for Expansion of Nimbeti Limestone Mine 422 - 429
10 Trace Metal Analysis Reports 430 -435
11 Letter received from RSPCB regarding distance of Plant site with Critically Polluted Area 436
12 Public Hearing Proceedings 437 - 460
13 Permission for use of Hazardous Waste from RSPCB 461 - 477
ix
FIGURE NO. PARTICULARS PAGE NO.
3.13(A) Graph showing PM10 Concentrations (Max. &Min.) at different monitoring stations 90
3.13(B) Graph showing PM2.5 Concentrations (Max. & Min.) at different monitoring stations 90
3.13 (C) Graph showing SO2 Concentrations (Max. & Min.) at different monitoring stations 91
3.13 (D) Graph showing NOxConcentrations (Max. & Min.) at different monitoring stations 91
3.14 (A) Graph showing Noise Levels of different locations during day time 96
3.14(B) Graph showing Noise Levels of different locations during night time 96
3.15 Key Plan showing Ground Water and Soil Sampling Locations 98
3.16 Demographic Profile of the Study Area 113
3.17 SC / ST Population within 10 Km Study Area 114
3.18 Gender Wise Literacy Details 115
3.19 Working Details 116
4.1 Isopleth showing the incremental GLCs of PM10 due to Plant activities 128
4.2 Isopleth showing the incremental GLCs of SO2due to Plant activity 129
4.3 Isopleth showing the incremental GLCs of NO2 due to Plant activities 130
4.4 Isopleth showing the incremental GLCs of PMdue to Plant and Mining activities 131
4.5 Traffic Volume Count 133
6.1 Structure of EMC at Shree Cement Plant (Pali) 146
8.1 Major areas under ESC activities 185
10.1 Existing Air Pollution Control Equipments 200
10.2 Existing Storage Facilities 203
10.3 Schematic diagram of Sewage Treatment Plant 211
10.4 Photographs of Existing STP 212
10.5 Photographs showing Rain Water Harvesting 213
11.1 Brief Description of the Project 236
11.2 Raw Material Requirement, Source and Transportation for Clinkerization and CPP 237
11.3 Raw Materials Requirement for Synthetic Gypsum Unit 238
11.4 Fuel Requirement 238
11.5 Basic Requirements for the Project 239
11.6 Post Project Monitoring 242
LIST OF ANNEXURES
ANNEXURE NO. DETAILS PAGE NO.
1 (a) Environmental Clearance Letters 247 - 293
1 (b) Certified EC Compliance 294 - 307
1 (c) Status of Compliance of Consent to Operate 308 - 315
2 CGWA Permission for Ground Water 316 - 320
3 Hydro-geological Study Report 321 - 371
4 Hourly Meteorological data 372 - 382
5 Detailed Ambient Air Quality Monitoring Tables 383 - 394
6 Note on Polluted Stretch of River in Rajasthan 395 -396
7 (a) Format for OHS 397 - 398
7 (b) Sample Test Report of OHS 399 - 404
8 Corporate Environment Policy 405 - 409
9 (a) EC Letter - Nimbeti Limestone Mine 410 - 421
9 (b) ToR Letter for Expansion of Nimbeti Limestone Mine 422 - 429
10 Trace Metal Analysis Reports 430 -435
11 Letter received from RSPCB regarding distance of Plant site with Critically Polluted Area 436
12 Public Hearing Proceedings 437 - 460
13 Permission for use of Hazardous Waste from RSPCB 461 - 477
ix
FIGURE NO. PARTICULARS PAGE NO.
3.13(A) Graph showing PM10 Concentrations (Max. &Min.) at different monitoring stations 90
3.13(B) Graph showing PM2.5 Concentrations (Max. & Min.) at different monitoring stations 90
3.13 (C) Graph showing SO2 Concentrations (Max. & Min.) at different monitoring stations 91
3.13 (D) Graph showing NOxConcentrations (Max. & Min.) at different monitoring stations 91
3.14 (A) Graph showing Noise Levels of different locations during day time 96
3.14(B) Graph showing Noise Levels of different locations during night time 96
3.15 Key Plan showing Ground Water and Soil Sampling Locations 98
3.16 Demographic Profile of the Study Area 113
3.17 SC / ST Population within 10 Km Study Area 114
3.18 Gender Wise Literacy Details 115
3.19 Working Details 116
4.1 Isopleth showing the incremental GLCs of PM10 due to Plant activities 128
4.2 Isopleth showing the incremental GLCs of SO2due to Plant activity 129
4.3 Isopleth showing the incremental GLCs of NO2 due to Plant activities 130
4.4 Isopleth showing the incremental GLCs of PMdue to Plant and Mining activities 131
4.5 Traffic Volume Count 133
6.1 Structure of EMC at Shree Cement Plant (Pali) 146
8.1 Major areas under ESC activities 185
10.1 Existing Air Pollution Control Equipments 200
10.2 Existing Storage Facilities 203
10.3 Schematic diagram of Sewage Treatment Plant 211
10.4 Photographs of Existing STP 212
10.5 Photographs showing Rain Water Harvesting 213
11.1 Brief Description of the Project 236
11.2 Raw Material Requirement, Source and Transportation for Clinkerization and CPP 237
11.3 Raw Materials Requirement for Synthetic Gypsum Unit 238
11.4 Fuel Requirement 238
11.5 Basic Requirements for the Project 239
11.6 Post Project Monitoring 242
LIST OF ANNEXURES
ANNEXURE NO. DETAILS PAGE NO.
1 (a) Environmental Clearance Letters 247 - 293
1 (b) Certified EC Compliance 294 - 307
1 (c) Status of Compliance of Consent to Operate 308 - 315
2 CGWA Permission for Ground Water 316 - 320
3 Hydro-geological Study Report 321 - 371
4 Hourly Meteorological data 372 - 382
5 Detailed Ambient Air Quality Monitoring Tables 383 - 394
6 Note on Polluted Stretch of River in Rajasthan 395 -396
7 (a) Format for OHS 397 - 398
7 (b) Sample Test Report of OHS 399 - 404
8 Corporate Environment Policy 405 - 409
9 (a) EC Letter - Nimbeti Limestone Mine 410 - 421
9 (b) ToR Letter for Expansion of Nimbeti Limestone Mine 422 - 429
10 Trace Metal Analysis Reports 430 -435
11 Letter received from RSPCB regarding distance of Plant site with Critically Polluted Area 436
12 Public Hearing Proceedings 437 - 460
13 Permission for use of Hazardous Waste from RSPCB 461 - 477
x
ABBREVIATIONS
AAQM : Ambient Air Quality Monitoring
AAQMS : Ambient Air Quality Monitoring Stations
AERMOD : Atmospheric Dispersion Modelling
AFBC : Atmospheric Fluidized Bed Combustion
APM : Air Particulate Matter
AQC : Air Quenched Cooler
BDL : Below Detection Limit
BIS : Bureau of Indian Standards
BOD : Bio-chemical Oxygen Demand
CAGR : Compound Annual Growth Rate
CAZRI : Central Arid Zone Research Institute
CEP : Corporate Environment policy
CFU : Colony Forming Unit
CFBC : Circulating Fluidized Bed Combustion
CGWA : Central Ground Water Authority
CPCB : Central Pollution Control Board
CMT : Crisis Management Team
CO : Carbon Monoxide
CREP : Corporate Responsibility for Environment Protection
CSR : Corporate Social Responsibility
CTE : Consent to Establish
CTO : Consent to Operate
DEM : Digital Elevation Model
D.G : Diesel Generator
DIP : Digital Image Processing
DL : Detection Limit
DO : Dissolved Oxygen
DMP : Disaster Management Plan
DTM : Digital Terrain Model
EAC : Expert Appraisal Committee
EC : Environmental Clearance
ECC : Emergency Control Centre
ECG : Electrocardiograph
EIA : Environmental Impact Assessment
EMC : Environment Management Cell
EMP : Environmental Management Plan
ENE : East of North-East
EPA : Environmental Protection Authority
ERDAS : Earth Resources Data Analysis System
ERT : Emergency Response Team
ESE : East of South East
ESC : Enterprise Social Commitment
ESP : Electrostatic Precipitator
FCC : False Color Composite
FHZ : Flood Hazard Zonation
FPM : Fine Particulate Matter
FPS : Fine Particulate Sampler
FY : Financial Year
GIS : Geographic Information System
GCP : Ground Control Points
GDP : Gross Domestic Product
GHG : Greenhouse Gases
GOI : Government of India
xi
GOVT. : Government
GPS : Global Positioning System
GLC : Ground Level Concentration
Ha : Hectare
HAZID : Hazard Identification
HC : Hydrocarbons
HSD : High Speed Diesel
HSE : Health, Safety & Environment
IIM : Indian Institute of Management
I&M : Inspection & Maintenance
ISO : International Organization for Standardization
ISRO : Indian Space Research Organization
IMD : India Meteorological Department
IOC : Indian Oil Corporation
IRP : Indian Response Plan
IRT : Incident Response Team
IS : Indian Standards
JMEPL : J.M. EnviroNet Private Limited
KLD : Kilo Litre Per Day
KWH : Kilo Watt Hour
LULC : Land Use/Land Cover
MT : Metric Tonne
MTPA : Million Tonnes Per Annum
MoEF&CC : Ministry of Environment and Forest & Climate Change
MW : Mega Watt
MVA : Mega Volt Ampere
NAAQS : National Ambient Air Quality Standards
NABL : National Accreditation Board For Testing And Calibration Laboratories
NABET : National Accreditation Board for Education & Training
NGO : Non- Governmental Organization
NATMO : National Atlas Thematic Mapping Organization
NDIR : Non-dispersive Infrared Detector
NE : North East
NH : National Highway
NIDM : National Institute of Disaster Management
NOC : No Objection Certificate
NNE : North of Northeast
NOx : Oxides of Nitrogen
NRSA : National Remote Sensing Agency
NTU : Nephlometeric Turbidity Unit
NW : North West
OHS : Occupational Health & Safety
OHSAS : Occupational Health & Safety Assessment Series
OPC : Ordinary Portland Cement
PAH : Poly Aromatic Hydrocarbon
PF : Protected Forest
pH : Potential Hydrogen
PHC : Public Health Centers
PM : Particulate Matter
PPC : Portland Pozzolana Cement
PPE : Personal Protective Equipments
PPM : Parts Per Million
QCI : Quality Council of India
RABH : Reverse Air Bag House
RDS : Respiratory Dust Sampler
RI : Rainfall Infiltration
xii
RO : Regional Office
RSPM : Respirable Suspended Particulate Matter
R & R : Rehabilitation & Resettlement
RSMM : Rajasthan State Mines & Minerals Ltd.
RSPCB : Rajasthan State Pollution Control Board
S : South
SC : Scheduled Caste
SE : South East
SEAC : State Level Expert Appraisal Committee
SEIAA : State Environment Impact Assessment Authority
SCL : Shree Cement Limited
SOI : Survey of India
SPM : Suspended Particulate Matter
SRTM : Shuttle Radar Topographic Mission
SW : South West
ST : Scheduled Tribes
TDS : Total Dissolved Solids
ToR : Terms of Reference
TPD : Tonnes Per Day
TPH : Tonnes Per Hour
USEPA : United States Environmental Protection Agency
USDA : United States Department of Agriculture
UTM : Universal Transverse Mercator
VAT : Value Added Tax
WHRB : Waste Heat Recovery Boiler
µg/m3 : Micro gram per metre cube
µm : Micro metre
µS/cm : Micro Siemens per centimetre
dB : Decibel
g/CC : Gram per cubic centimetre
g/km hr : Gram per kilometer hour
ha : Hectare
kg/ha : Kilogram per hectare
km : Kilometre
m : Metre
mg/kg : Milligram per kilogram
mg/l : Milligram per litre
mg/m3 : Milligram per metre cube
mg/Nm3 : Milligram per Newton cubic metre
mm : Millimetre
mS/cm : MilliSiemens per centimetre
sq. : Square
xii
RO : Regional Office
RSPM : Respirable Suspended Particulate Matter
R & R : Rehabilitation & Resettlement
RSMM : Rajasthan State Mines & Minerals Ltd.
RSPCB : Rajasthan State Pollution Control Board
S : South
SC : Scheduled Caste
SE : South East
SEAC : State Level Expert Appraisal Committee
SEIAA : State Environment Impact Assessment Authority
SCL : Shree Cement Limited
SOI : Survey of India
SPM : Suspended Particulate Matter
SRTM : Shuttle Radar Topographic Mission
SW : South West
ST : Scheduled Tribes
TDS : Total Dissolved Solids
ToR : Terms of Reference
TPD : Tonnes Per Day
TPH : Tonnes Per Hour
USEPA : United States Environmental Protection Agency
USDA : United States Department of Agriculture
UTM : Universal Transverse Mercator
VAT : Value Added Tax
WHRB : Waste Heat Recovery Boiler
µg/m3 : Micro gram per metre cube
µm : Micro metre
µS/cm : Micro Siemens per centimetre
dB : Decibel
g/CC : Gram per cubic centimetre
g/km hr : Gram per kilometer hour
ha : Hectare
kg/ha : Kilogram per hectare
km : Kilometre
m : Metre
mg/kg : Milligram per kilogram
mg/l : Milligram per litre
mg/m3 : Milligram per metre cube
mg/Nm3 : Milligram per Newton cubic metre
mm : Millimetre
mS/cm : MilliSiemens per centimetre
sq. : Square
xii
RO : Regional Office
RSPM : Respirable Suspended Particulate Matter
R & R : Rehabilitation & Resettlement
RSMM : Rajasthan State Mines & Minerals Ltd.
RSPCB : Rajasthan State Pollution Control Board
S : South
SC : Scheduled Caste
SE : South East
SEAC : State Level Expert Appraisal Committee
SEIAA : State Environment Impact Assessment Authority
SCL : Shree Cement Limited
SOI : Survey of India
SPM : Suspended Particulate Matter
SRTM : Shuttle Radar Topographic Mission
SW : South West
ST : Scheduled Tribes
TDS : Total Dissolved Solids
ToR : Terms of Reference
TPD : Tonnes Per Day
TPH : Tonnes Per Hour
USEPA : United States Environmental Protection Agency
USDA : United States Department of Agriculture
UTM : Universal Transverse Mercator
VAT : Value Added Tax
WHRB : Waste Heat Recovery Boiler
µg/m3 : Micro gram per metre cube
µm : Micro metre
µS/cm : Micro Siemens per centimetre
dB : Decibel
g/CC : Gram per cubic centimetre
g/km hr : Gram per kilometer hour
ha : Hectare
kg/ha : Kilogram per hectare
km : Kilometre
m : Metre
mg/kg : Milligram per kilogram
mg/l : Milligram per litre
mg/m3 : Milligram per metre cube
mg/Nm3 : Milligram per Newton cubic metre
mm : Millimetre
mS/cm : MilliSiemens per centimetre
sq. : Square
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 12 JM EnviroNet Pvt. Ltd.
ToR Compliance
Point-wise compliance to the ToR points issued by MoEFCC, New Delhi vide letter no. J - 11011/343/2012-IAII (I)
dated 10th Feb., 2016for Proposed Expansion of Integrated Cement Plant - Clinker (11.2 to 15.0 Million TPA),
Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) and DG
Sets (1000 to 2000 KVA) near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)by M/s. Shree Cement
Limited.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
Generic ToRs in respect of Industry Sector
1. Executive Summary Executive Summary of the project has been
incorporated in this EIA/EMP Report.
Chapter - XI, Page
no.235
2. Introduction
i. Details of the EIA Consultant including
NABET accreditation.
Details of the EIA Consultant including NABET
accreditation has been incorporated in this
EIA/EMP Report.
Chapter - XII, Page
no.245
ii. Information about the project
proponent.
Information about the project proponent has been
incorporated in this EIA/EMP Report.
Chapter - I,
Section 1.2.1,Page
no. 28
iii. Importance and benefits of the
project.
Importance and benefits of this project has been
given in this EIA/EMP Report.
Chapter - I,
Section 1.3.5, Page
no.41
3. Project Description
i. Cost of project and time of
completion.
Total Cost
of Project
Rs. 755 Crores Chapter - VI, Page
no. 150
Chapter - I,
Section 1.2.1,Page
no. 32
Time of
Completion
Proposed Expansion
in Unit - IX &X
2 months*
Proposed Unit - XI 18 months*
*after getting all the regulatory approvals.
Details of activities along with time
required has been incorporated in
this EIA/EMP Report.
ii. Products with capacities for the
proposed project.
Details of products with capacities for the
proposed expansion project have been
incorporated in this EIA/EMP Report.
Chapter - I, Table
1.2, Page no.31
iii. If expansion project, details of existing
products with capacities and whether
adequate land is available for
expansion, reference of earlier EC if
any.
o Details of existing products with capacities
have been incorporated in this EIA/EMP Report.
Environmental Clearance for existing Cement
Plant near Village: Ras, Tehsil: Jaitaran, District:
Pali (Rajasthan)has been obtained from
Chapter - I, Table
1.2, Page no.31
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 13 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
MoEFCC, New Delhi vide Letter No. J-
11011/343/2012-IA-II(I) dated 10th September,
2015.
Copy of the same has been enclosed as Annexure
- 1 (a) along with this EIA/EMP Report.
o Total plant area is 231.54 ha (which includes
187.56 ha existing plant areaand 43.98 ha
additional area within plant boundary);72.7 ha
area is also available outside the plant
boundary for future useand all the land is under
possession of M/s. Shree Cement Ltd.The
existing available area is adequate for proposed
expansion project.
Annexure - 1 (a),
Page no. 247
Chapter - II,
Section 2.5, Page
no. 50
iv. List of raw materials required and their
source along with mode of
transportation.
List of raw materials required, their source along
with their mode of transportation has been
incorporated in this EIA/EMP Report.
Chapter - II, Table
2.1&2.2, Page no.
44
v. Other chemicals and materials
required with quantities and storage
capacities.
No other chemical is required for this proposed
expansion project.
-
vi. Details of Emission, effluents,
hazardous waste generation and their
management.
Emission Major emissions from the project
are of PM, SO2 and NOx. Details are
given in this EIA/EMP Report.
Chapter - X, Table
10.2, Page no. 201
Chapter - II, Figure
2.2, Page no. 48
Chapter - X, Table
10.6, Page no. 214
Effluent RO reject water (310 KLD) will be
used in manufacturing of synthetic
gypsum and for dust suppression /
ash quenching.
Domestic wastewater (430 KLD)
generated from plant and colony
will be treated in STP and treated
water (415 KLD) will be utilized in
greenbelt development/ plantation.
Hazardous
Waste
325 MT/annum of Used oil
(Hazardous Waste) will be
generated, which will be sold to the
CPCB authorized recycler.
vii. Requirement of water, power, with
source of supply, status of approval,
water balance diagram, man-power
requirement (regular and contract)
ParticularTotal requirement
after expansionSource
Chapter - II,
section 2.4.3, Page
no. 46Water 3500 m3/day Ground Water*
Power 158.9 MW Captive Power
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 14 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
Plant, WHRB,
Grid & D.G Sets
(for backup)
Annexure - 2, Page
no. 316
Chapter - II, Figure
2.2, Page no. 48
Manpower 3411 Persons
(Regular- 1460 +
Contractual - 1951)
Unskilled /
Semi-skilled -
local area;
Skilled -
Rajasthan and
outside
Rajasthan
*Status of Approval:Permission for withdrawal of
ground water (4000 m3/day) has already been
obtained from CGWA for existing plant, CPP and
Nimbeti Limestone Mine vide letters dated
23rdMay, 2011; 12th July, 2013 and11th Feb., 2014.
Copy of all the letters has been enclosed as
Annexure - 2 along with this EIA / EMP Report.
Water balance diagram has also been incorporated
in this EIA/EMP Report.
viii. Process description along with major
equipments and machineries, process
flow sheet (quantitative) from raw
material to products to be provided.
o Process description along with major
equipments and machineries has been
incorporated in this EIA/EMP Report.
o Process flow sheet (quantitative) from raw
material to products / mass balance has also
been incorporated in this EIA/EMP Report.
Chapter - II,
Section2.6, Page
no. 53
Chapter - II, Figure
2.4, Page no. 55
ix. Hazard identification and details of
proposed safety systems.
Hazard identification and details of proposed
safety systems has been incorporated in this
EIA/EMP Report.
Chapter - VII,
Section 7.4.2, Page
no.159
x. Expansion / modernization proposals:
a) Copy of all the Environmental
Clearance(s) including Amendments
thereto obtained for the project from
MOEF/SEIAA shall be attached as an
Annexure.
A certified copy of the latest
Monitoring Report of the regional
office of the Ministry of Environment
and Forests as per circular dated 30th
May, 2012 on the status of compliance
of conditions stipulated in all the
o Copy of all the Environmental Clearances (EC)
obtained for the existing plant from MoEFCC,
New Delhi has been enclosed asAnnexure -
1(a)along with this EIA/EMP Report; and details
of the same are given in this EIA/EMP Report.
o The status of compliance of the conditions
stipulated in the EC for the existing capacity of
the plant duly certified by RO, MoEFCC has
been enclosed as Annexure - 1 (b) along with
this EIA/EMP Report.
Annexure - 1 (a),
Page no. 247
Annexure - 1 (b),
Page no. 294
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 15 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
existing environmental clearances
including Amendments shall be
provided.
In addition, status of compliance of
Consent to Operate for the ongoing/
existing operation of the project from
SPCB shall be attached with the EIA-
EMP report.
o Status of compliance of Consent to Operate for
the ongoing/ existing operation of the project
has been enclosed as Annexure - 1 (c) along
with this EIA/EMP Report.
Annexure - 1 (c),
Page no. 308
b) In case the existing project has not
obtained environmental clearance,
reasons for not taking EC under the
provisions of the EIA Notification 1994
and /or EIA Notification 2006 shall be
provided. Copies of Consent to
Establish/No Objection Certificate and
Consent to Operate (in case of units
operating prior to EIA Notification
2006, CTE and CTO of FY 2005 - 2006)
obtained from the SPCB shall be
submitted. Further, Compliance report
to the conditions of consents from the
SPCB shall be submitted.
Not applicable; as Environmental Clearance has
already been obtained for the existing project.
-
4. Site Details
i. Location of the project site covering
village, Taluka/Tehsil, District and
State, Justification for selecting the
site, whether other sites were
considered.
o Location map showing the plant site along with
village, tehsil, district and state has been
incorporated in this EIA/EMP Report.
o No alternative site has been considered for the
proposed expansion project as the same will be
done on additional area availablewithin
theplant boundary.
Chapter - I, Figure -
1.2, Page no. 36
Chapter - I,
Section 1.3.3, Page
no. 40
ii. A toposheet of the study area of radius
of 10 km and site location on 1:50,000/
1:25,000 scale on an A3/A2 sheet
(including all eco-sensitive areas and
environmentally sensitive places).
Map showing plant site and 10 km radius study
area on Toposheet of 1:50,000 scale on an A3
sheet has been incorporated in this EIA/EMP
Report.
Chapter - I, Figure -
1.5, Page no. 39
iii. Co-ordinates (lat-long) of all four
corners of the site.
Corner Co-ordinates of the plant site are given in
this EIA/EMP Report.
Chapter - I, Table
1.4, Page no. 34
iv. Google map-Earth downloaded of the
project site.
Google Earth downloaded map of the plant site is
given in this EIA/EMP Report.
Chapter - I, Figure -
1.4, Page no. 38
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 16 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
v. Layout maps indicating existing unit as
well as proposed unit indicating
storage area, plant area, green belt
area, utilities etc. If located within an
industrial area/Estate/Complex, layout
of Industrial Area indicating location of
unit within the Industrial area/Estate.
Plant Layout showing existing unit as well as
proposed unit, storage area, green belt area, other
utilities etc. is incorporated in this EIA/EMP Report.
Existing plant is not located in industrial area/
Estate/ Complex.
Chapter - II, Figure
-2.3, Page no. 52
vi. Photographs of the proposed and
existing (if applicable) plant site. If
existing, show photographs of
plantation/ greenbelt, in particular.
o Photographs of existing and proposed plant
site have been incorporated in this EIA/EMP
Report.
o Photographs showing existing greenbelt/
plantation have also been incorporated in this
EIA/EMP Report.
Chapter - I, Figure-
1.6 (a) and 1.6 (b),
Page no. 40
Chapter - X,
Section 10.7.4,
Page no. 220
vii. Land use break-up of total land of the
project site (identified and acquired),
government / private - agriculture,
forest, wasteland, water bodies,
settlements, etc. shall be included (not
required for industrial area).
Total plant area is 231.54 ha (which includes 187.56
ha existing plant areaand 43.98 ha additional area
within plant boundary); 72.7 ha area is also
available outside the plant boundary for future use
and all the land is under possession of SCL.
Land break-up of total land of the plant site has
been incorporated in this EIA/EMP Report.
Chapter - II,
Section 2.5, Page
no. 50
viii. A list of major industries with name
and type within study area (10 km
radius) shall be incorporated. Land use
details of the study area.
o List of major industries with name and type
within the study area (10 km radius) has been
incorporated in this EIA / EMP Report.
o Land use details of the study area have also
been incorporated in this EIA/EMP Report.
Chapter - III, Table
3.27, Page no. 117
Chapter - III,
Section 3.4.4.2.2,
Page no. 73
ix. Geological features and Geo-
hydrological status of the study area
shall be included.
Details regarding Geological features and Geo-
hydrological status of the study area have been
incorporated in Hydro-geological report enclosed
as Annexure - 3 along with this EIA/EMP Report.
Annexure - 3, Page
no. 321
x. Details of Drainage of the project up to
5 km radius of study area. If the site is
within 1 km radius of any major river,
peak and lean season river discharge
as well as flood occurrence frequency
based on peak rainfall data of the past
30 years. Details of Flood Level of the
project site and maximum Flood Level
of the river shall also be provided
(mega green field projects).
Map showing drainage of the plant site and 10 km
radius study areahas been incorporated in Hydro-
geological report enclosed as Annexure - 3 along
with this EIA/EMP Report.
Plant Site does not fall within 1 km radius of any
major River.
Annexure - 3, Page
no. 321
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 17 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
xi. Status of acquisition of land. If
acquisition is not complete, stage of
the acquisition process and expected
time of complete possession of the
land.
Proposed expansion will be done on additional
area available within the plant boundary.
-
xii. R & R details in respect of land in line
with state Government policy.
R & R is not applicable; as the proposed expansion
will be done on additional area available within the
plant boundary.
-
5. Forest and Wildlife related issues (if applicable)
i. Permission and approval; for the use
of forest land (forestry clearance), if
any, and recommendations of the
State Forest Department (if
applicable)
No forest land is involved in the proposed
expansion project; thus, no such permission /
approval is required.
-
ii. Land use map based on High
resolution satellite imagery (GPS) of
the proposed site delineating the
forestland (in case of projects
involving forest land more than 40 ha)
No forest land is involved in the proposed
expansion project.
-
iii. Status of Application submitted for
obtaining the stage I forestry
clearance along with latest status shall
be submitted.
Not applicable. -
iv. The projects to be located within 10
km of the National Parks, Sanctuaries,
Biosphere Reserves, Migratory
Corridors of Wild Animal; the project
proponent shall submit the map duly
authenticated by Chief Wildlife
Warden showing these features vis-a-
vis the project location and the
recommendations or comments of the
Chief Wildlife Warden - thereon.
No National Park, Sanctuary, Biosphere Reserve,
Migratory Corridor of wild animals exists within 10
km radius study area.
Map showing 10 km radius study area has been
incorporated in this EIA/EMP Report.
Chapter - I, Figure -
1.5, Page no. 39
v. Wildlife Conservation Plan duly
authenticated by the Chief Wildlife
Warden of the state government for
conservation of schedule I fauna, if any
exists in the study area.
No Schedule - I fauna was found within 10 km
radius of the study area during biological study.
List of fauna found within 10 km radius study area
have been incorporated in this EIA/EMP Report.
Chapter - III, Table
3.20, Page no. 107
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 18 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
vi. Copy of application submitted for
clearance under the Wildlife
(Protection) Act, 1972, to the Standing
Committee of the National Board for
Wildlife.
Not applicable. -
6. Environmental Status
i. Determination of atmospheric
inversion level at the project site and
site-specific micro-meteorological data
using temperature, relative humidity,
hourly wind speed and direction and
rainfall.
Details of atmospheric inversion level have been
incorporated in this EIA/EMP Report.
Site-specific micro-meteorological data
(temperature, relative humidity, wind speed and
direction) were collected during Summer Season
(March to May, 2015). Details of the same have
been incorporated in this EIA/EMP Report.
Hourly meteorological data has been enclosed as
Annexure - 4 along with thisEIA/EMP Report.
Chapter - IV, Table
4.3, Page no. 126
Chapter - III,
Section 3.7.1, Page
no. 84
Annexure - 4, Page
no. 372
ii. AAQ data (except monsoon) at 8
locations for PM10, PM2.5, SO2, NOx,
CO and other parameters relevant to
the project shall be collected. The
monitoring stations shall be based
CPCB guidelines and take into account
the pre-dominant wind direction,
population zone and sensitive
receptors including reserved forests.
Composite AAQ monitoring (Plant and Mine) was
carried out at 12 locations during Summer Season
(March to May, 2015) within 10 km radius study
area.
The monitoring stations were selected taking into
account the dominant wind direction, population
zone and sensitive receptors etc.
Detail of the same has been incorporated in this
EIA/EMP Report.
Chapter - III,
Section 3.8, Page
no. 86
iii. Raw data of all AAQ measurement for
12 weeks of all stations as per
frequency given in the NAQQM
Notification of Nov. 2009 along with-
min., max., average and 98% values for
each of the AAQ parameters from data
of all AAQ stations should be provided
as an annexure to the EIA Report.
Raw data of all AAQ measurement / detailed
AAQM Tables of all AAQ stations along with min.,
max., average and 98% values for each of the AAQ
parameters have been enclosed as Annexure - 5
along with this EIA/EMP Report.
Annexure - 5, Page
no. 383
iv. Surface water quality of nearby River
(60m upstream and downstream) and
other surface drains at eight locations
as per CPCB/MoEF&CC guidelines.
Lilri River (~1.5 km in North direction) and Sukri
River (~8.0 km in SSW direction) are present
within 10 km radius of the plant and mine site.
Surface water samples were not collected from
the above two locations as both the water bodies
are seasonal and were found dry during the study
period.
Chapter - III,
Section 3.10.1,
Page no. 97
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 19 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
v. Whether the site falls near to polluted
stretch of river identified by the
CPCB/MoEF&CC.
Plant site does not fall near to polluted stretch of
river identified by the CPCB/MoEFCC.
Annexure - 6, Page
no. 395
vi. Ground water monitoring minimum at
8 locations shall be included.
Ground water monitoring (composite for Plant
and Mine) was carried out at 9 locations in the
study area during Summer Season (March to May,
2015).
Details of the same have been incorporated in this
EIA/EMP Report.
Chapter - III,
Section 3.10.2,
Page no. 97
vii. Noise levels monitoring at 8 locations
within the study area.
Noise level monitoring (composite for Plant and
Mine) was carried out at 12 locations within the
study area during Summer Season (March to May,
2015).
Details of the same have been incorporated in this
EIA/EMP Report.
Chapter - III,
Section 3.9, Page
no. 94
viii. Soil Characteristics as per CPCB
guidelines.
Soil sampling (composite for Plant and Mine) was
carried out for 9 locations within the study area
during Summer Season (March to May, 2015).
Details of the same have been incorporated in this
EIA/EMP Report.
Chapter - III,
Section 3.11, Page
no. 101
ix. Traffic study of the area, type of
vehicles, frequency of vehicles for
transportation of materials, additional
traffic due to proposed project,
parking arrangement etc.
Traffic study of the area in respect of existing
traffic, type of vehicles, frequency of vehicles for
transportation of materials, additional traffic due
to proposed expansion, parking arrangement etc.
was conducted and details for the same have been
incorporated in this EIA/EMP Report.
Chapter - IV,
Section 4.4.2.3,
Page no. 132
x. Detailed description on flora and fauna
(terrestrial and aquatic) existing in the
study area shall be given with special
reference to rare, endemic and
endangered species. If Schedule-I
fauna are found within the study area,
a Wildlife Conservation Plan shall be
prepared and furnished.
Details of the flora and fauna found within the
study area have been given in this EIA/EMP
Report.
No Schedule - I fauna was found within 10 km
radius of the study area during biological study.
Chapter - III,
Section 3.12, Page
no. 104
xi. Socio-economic status of the study
area.
Details reg. Socio-economic status of the study
area has been incorporated in this EIA/EMP
Report.
Chapter - III,
Section 3.13, Page
no. 109
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 20 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
7. Impact Assessment and Environment Management Plan
i. Assessment of ground level
concentration of pollutants from the
stack emission based on site-specific
meteorological features. In case the
project is located on hilly terrain
characteristics for determining the
potential impacts of the project on the
AAQ. Cumulative impact of all sources
of emissions (including transportation)
on the AAQ of the area shall be well
assessed. Details of the model used
and the input data used for modeling
shall also be provided. The air quality
contours shall be plotted on a location
map showing the location of project
site, habitation nearby, sensitive
receptors, if any.
The incremental ground level concentration of
pollutants from the stack emissions based on site-
specific meteorological features has been
predicted via computation done through
mathematical modeling and incorporated in this
EIA/EMP Report.
The project site is not located on a hilly terrain.
Cumulative impact (plant and captive mine)of all
the sources of emissions on the AAQ of the area
was assessed.Details of the same along with
details of the model used and the input data used
for modeling have been incorporated in this
EIA/EMP Report.
Isopleths showing air quality contours plotted on
location map have also been incorporated in this
EIA/EMP Report.
Chapter - IV,
Section 4.4.2.2,
Page no. 122
Chapter - IV,
Figure 4.1 to 4.4,
Page no. 128- 131
ii. Water Quality modeling- in case, if the
effluent is proposed to be discharged
in to the local drain, then Water
Quality Modeling study should be
conducted for the drain water taking
into consideration the upstream and
downstream quality of water of the
drain.
No wastewater is being / will be discharged from
the cement plant.
Same has been shown in water balance diagram
given in this EIA/EMP Report.
Therefore, water quality modeling study is not
required.
Chapter - II, Figure
2.2, Page no. 48
iii. Impact of the transport of the raw
materials and end products on the
surrounding environment shall be
assessed and provided. In this regard,
options for transport of raw materials
and finished products and wastes
(large quantities) by rail or rail-cum
road transport or conveyor-cum-rail
transport shall be examined.
There will be no major impact of the transport of
the raw materials and end products on the
surrounding environment due to proposed
expansion project as proper mitigation measures
will be adopted.
Major raw material i.e. Limestone will be
transported by covered conveyor belt.
Details reg. impact of the transport of the raw
materials and end products on the surrounding
environment along with option for rail
transporthas been incorporated in this EIA/EMP
Report.
Chapter - IV,
Section 4.4.2.3,
Page no. 132
iv. A note on treatment of wastewater
from different plant operations, extent
No waste water is being / will be generated from
the cement manufacturing process.
Chapter - X,
Section 10.4, Page
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 21 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
recycled and reused for different
purposes shall be included.
Complete scheme of effluent
treatment. Characteristics of
untreated and treated effluent to
meet the prescribed standards of
discharge under E (P) Rules.
RO reject water (310 KLD)is being / will be used in
Synthetic Gypsum manufacturing process, ash
quenching and dust suppression.
Domestic wastewater (430 KLD)generated from
plant and colony is being / will be treated in STP
and treated water is being / will be utilized
forgreenbelt development / plantation.
Rain water harvesting is being / will be practiced
inside the plant and colony premises.
Details of the same have been incorporated in this
EIA/EMP Report.
no. 210
v. Details of stack emission and action
plan for control of emissions to meet
standards.
Stack emission details have been incorporated in
this EIA/EMP Report.
Efficient Air Pollution Control Equipment (APCE)
will be installedfor the control of emissions from
all the sourceswithin the prescribed limit.
Details of the same have been incorporated in this
EIA/EMP Report.
Chapter - X, Table
10.2, Page no. 201
Chapter - X, Table
10.1, Page no. 200
vi. Measures for fugitive emission control. Measures for control of fugitive emission have
been incorporated in this EIA/EMP Report.
Chapter - X,
Section 10.2.2,
Page no. 201
vii. Details of hazardous waste generation,
and their storage, utilization and
disposal. Copies of MOU regarding
utilization of solid and hazardous
waste shall also be included. EMP shall
include the concept of waste-
minimization, recycle/ reuse/ recover
techniques, energy conservation, and
natural resource conservation.
Details regarding hazardous waste have been
incorporated in this EIA/EMP Report.
Concept of waste - minimization, recycle/ reuse /
recover techniques, Energy conservation and
natural resource conservation has been included in
the EMP and details reg. the same have been
incorporated in this EIA/EMP Report.
Chapter - X,
Section 10.5.2,
Page no. 214
Chapter - X,
Section 10.6,
Page no. 216
viii. Proper utilization of fly ash shall be
ensured as per Fly Ash Notification,
2009. A detailed plan of action shall be
provided.
Fly ash is one of the major components required
for manufacturing of PPC.
Fly ash generated from CPP is being / will be totally
consumed in the cement (PPC) manufacturing
process.
Details of the same have been incorporated in this
EIA / EMP Report.
Chapter - X, Table
10.5 (b), Page no.
214
ix. Action plan for the green belt
development plan in 33 % area i.e. land
with not less than 1,500 trees per ha.
Out of the total existing plant area i.e. 187.5 ha,
34% (i.e. 63.8 ha) has been developed under green
belt/ plantation. Additional 33% (i.e. 14.5 ha) will be
Chapter - X,
Section 10.7, Page
no. 217
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 22 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
Giving details of species, width of
plantation, planning schedule etc. shall
be included. The green belt shall be
around the project boundary and a
scheme for greening of the roads used
for the project shall also be
incorporated.
further developed for this expansion project.
Besides this, 33% (i.e. 24 ha) of the area available
outside the plant boundary (72.7 ha) will also be
developed under greenbelt / plantation, whenever
used in future.
Area of the township near village Bagatpura is 40
ha, out of which 14.5 ha (i.e. 36%) is developed
under greenbelt / plantation area.
Action Plan for green belt development along with
details of species, width of plantation, etc. has
been incorporated in this EIA / EMP Report.
x. Action plan for rainwater harvesting
measures at plant site shall be
submitted to harvest rainwater from
the roof tops and storm water drains
to recharge the ground water and also
to use for the various activities at the
project site to conserve fresh water
and reduce the water requirement
from other sources.
Action plan for rainwater harvesting measures at
plant site has been prepared to harvest rainwater
from the roof tops and storm water drains to
recharge the ground water and also to use for the
various activities at the plant site to conserve fresh
water and reduce the water requirement from
other sources.
Details of the same have been given in Hydro-
geological report enclosed as Annexure - 3 along
with this EIA/EMP Report.
Annexure - 3, Page
no. 321
xi. Total capital cost and recurring
cost/annum for environmental
pollution control measures shall be
included.
Cost for Environmental Protection Measures:
Capital Cost: Rs. 51 Crores
Recurring Cost: Rs. 1.0 Crores / annum.
Chapter - VI,
Section 6.6, Page
no. 150
xii. Action plan for post-project
environmental monitoring shall be
submitted.
Action plan for post-project environmental
monitoring has been incorporated in this EIA/EMP
Report.
Chapter - VI,
Table 6.2, Page
no. 147
xiii. Onsite and Offsite Disaster (natural
and Man-made) Preparedness and
Emergency Management Plan
including Risk Assessment and damage
control. Disaster management plan
should be linked with District Disaster
Management Plan.
Onsite and Offsite Disaster (natural and Man-
made) Preparedness and Emergency Management
Plan including Risk Assessment and damage
control has been incorporated in this EIA/EMP
Report.
Chapter - VII,
Section 7.4.4,
Page no. 166
8. Occupational health:
i. Details of existing Occupational &
Safety Hazards. What are the
exposure levels of above mentioned
hazards and whether they are within
Details regarding Occupational and Safety Hazards
along with exposure levels have been
incorporated in this EIA/EMP Report.
Exposure level of all the hazards are within in PEL.
Chapter - X,
Section 10.8, Page
no. 222
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 23 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
Permissible Exposure level (PEL).
If these are not within PEL, what
measures the company has adopted
to keep them within PEL so that
health of the workers can be
preserved.
ii. Details of exposure specific health
status evaluation of worker. If the
workers health is being evaluated by
pre designed format, chest x rays,
Audiometry, Spirometry, Vision testing
(Far & Near vision, colour vision and
any other ocular defect) ECG, during
pre-placement and periodical
examinations give the details of the
same. Details regarding last month
analyzed data of abovementioned
parameters as per age, sex, duration
of exposure and department wise.
Details of exposure specific health status
evaluation of workers have been given in this
EIA/EMP Report.
Format for pre-employment and periodic medical
examination has been enclosed as Annexure - 7(a)
along with this EIA/EMP Report.
Chapter - X,
Section 10.8, Page
no. 222
Annexure - 7(a),
Page no. 397
iii. Annual report of health status of
workers with special reference to
Occupational Health and Safety.
Annual sample report of health status of worker
with special reference to Occupational Health and
Safety has been enclosed as Annexure - 7(b) along
with this EIA/EMP Report.
Annexure - 7(b),
Page no. 399
iv. Plan and fund allocation to ensure the
occupational health & safety of all
contract and casual workers.
Plan and fund allocation to ensure the
occupational health and safety of all contract and
casual workers have been incorporated in this
EIA/EMP Report.
Chapter - X, Table
10.11, Page no. 231
9. Corporate Environment Policy:
i. Does the company have a well laid
down Environment Policy approved by
its Board of Directors? If so, it may be
detailed in the EIA report.
Corporate Environment Policy of the company has
been enclosed as Annexure - 8 along with this
EIA/EMP Report.
Annexure - 8,
Page no. 405
ii. Does the Environment Policy prescribe
for standard operating process /
procedures to bring into focus any
infringement / deviation / violation of
the environmental or forest norms /
conditions? If so, it may be detailed in
the EIA.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 24 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
iii. What is the hierarchical system or
Administrative order of the company
to deal with the environmental issues
and for ensuring compliance with the
environmental clearance conditions?
Details of this system may be given.
iv. Does the company have system of
reporting of non-compliances /
violations of environmental norms to
the Board of Directors of the company
and / or shareholders or stakeholders
at large? This reporting mechanism
shall be detailed in the EIA report.
10. Details regarding infrastructure
facilities such as sanitation, fuel,
restroom etc. to be provided to the
labor force during construction as well
as to the casual workers including
truck drivers during operation phase.
Details regarding infrastructure facilities to be
provided to the labour force during construction
as well as to the casual workers including truck
drivers during operation phase have been
incorporated in this EIA/EMP Report.
Chapter - II,
Section 2.6.6,
Page no. 61
11. Enterprise Social Commitment (ESC)
i. Adequate funds (at least 2.5 % of the
project cost) shall be earmarked
towards the Enterprise Social
Commitment based on Public Hearing
issues and item-wise details along with
time bound action plan shall be
included.Socio-economic development
activities need to be elaborated upon.
2.5% of the total project cost has been earmarked
towards the Enterprise Social Commitment (ESC)
based on Public Hearing issues and item-wise
details along with time bound action plan has been
prepared and incorporated in this EIA/EMP Report.
Details reg. Socio-economic development activities
have also been incorporated in this EIA/EMP
Report.
Chapter - VIII,
Table 8.2, Page
no. 194
Chapter - VIII,
Page no. 185
12. Any litigation pending against the
project and/or any direction/order
passed by any Court of Law against the
project, if so, details thereof shall also
be included. Has the unit received any
notice under the Section 5 of
Environment (Protection) Act, 1986 or
relevant Sections of Air and Water
Acts? If so, details thereof and
compliance/ATR to the notice(s) and
present status of the case.
No litigation is pending against the project and/or
any direction/order passed by any Court of Law
against the project.
The unit has not received any notice under the
Section 5 of Environment (Protection) Act, 1986 or
relevant Sections of Air and Water Acts.
-
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 25 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
13. A tabular chart with index for point
wise compliance of above TORs.
Point-wise compliance of the ToRs has been given
in the tabular form.
-
14. The TORs prescribed shall be valid for
a period of three years for submission
of the EIA-EMP reports along with
Public Hearing Proceedings (wherever
stipulated).
Noted. -
Additional ToRs for Cement Industry
1. Limestone and coal linkage documents
along with the status of environmental
clearance for limestone and coal
mines.
o Limestone is being / will be sourced from
existing captive Nimbeti Limestone Mine (ML
Area - 750 ha) with production capacity of 19.6
MTPA, near Village: Ras, Tehsil: Jaitaran,
District: Pali (Rajasthan); Environmental
Clearance for the same has been obtainedfrom
MoEFCC, New Delhi vide letter no. J-
11015/327/2012-IA II (M) dated 21st July, 2015.
Copy of EC Letter has been enclosed as Annexure
- 9(a) along with this EIA/EMP Report.
To cater the additional requirement of
limestone for proposed expansion of
Integrated Cement Project, SCL is also
proposing expansion in production capacity of
Captive Nimbeti Limestone Mine (ML Area: 750
ha) from 19.6 to 25.3 Million TPA.
TOR letter for the same has been obtained from
MoEFCC, New Delhi vide letter no. J-
11015/226/2015-IA II (M) dated 11th August 2015.
Copy of ToR Letter has been enclosed as
Annexure - 9(b) along with this EIA/EMP Report.
o SCL have an agreement with Xcoal Energy and
Resources, Reliance Industries Limited, Aditya
Birla Swiss Singapore and HC Trading Malta
Limited for procurement of Indian and
Imported Coal and Petcoke.
Annexure - 9(a),
Page no. 410
Annexure - 9(b),
Page no. 422
2. Quantum of generation of coal and
limestone from coal & limestone mines
and the projects they cater to.
o Fuel {Coal (Indian & Imported) /Petcoke (Indian
& Imported)/ Lignite} is being/will be procured
from Reliance, IOCL, Essar & other
Petrochemical Refineries, USA, Swiss, Saudi
Arabia, Rajasthan etc.
-
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 26 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
o Limestone will be sourced from existing
Captive Nimbeti Limestone Mine (M.L Area -
750 ha) with applied production capacity of
25.3 Million TPA.
3. Present land use shall be prepared
based on satellite imagery. High-
resolution satellite image data having
1m-5m spatial resolution like quickbird,
Ikonos, IRS P-6 pan sharpened etc. for
the 10 Km radius area from proposed
site. The same shall be used for land
used/land-cover mapping of the area.
Present land use / land cover map has been
prepared, based on satellite imagery, using
RESOURCESAT-2 (L4FMX) digital data which was
procured from National Remote Sensing Centre,
Hyderabad and the same have been incorporated
in this EIA/EMP Report.
Chapter - III,
Section 3.4.4.2.1,
Page no. 71
4. If the raw materials used have trace
elements, an environment
management plan shall also be
included.
Raw materials have been analyzed for trace
elements.
Test reports from the NABL authorized laboratory
for the same has been enclosed as Annexure -
10along with this EIA/EMP Report.
Annexure - 10,
Page no. 430
5. Plan for the implementation of the
recommendations made for the
cement plants in the CREP guidelines
must be prepared.
Plan for the implementation of the
recommendations made for the cement plants in
the CREP guidelines have been prepared and
incorporated in this EIA/EMP Report.
Chapter - X,
Section 10.11,
Page no. 233
6. Energy consumption per ton of clinker
and cement grinding.
Energy consumption per ton of clinker will be 54
Kwh and energy consumption per ton for cement
grinding will be 24 Kwh.
Chapter - II, Page
no. 49
7. Provision of waste heat recovery
boiler.
Presently, Waste Heat Recovery Boiler of capacity
68 MW is already installed. After proposed
expansion, capacity of WHRB will be expanded
from 68 MW to 90 MW.
Details of the same have been incorporated in this
EIA/EMP Report.
Chapter - II,
Section 2.6.25,
Page no. 56
8. Arrangement for co-processing of
hazardous waste in cement plant.
Details regarding use of co-processing of
hazardous waste in cement planthave been
incorporated in this EIA/EMP Report.
Chapter - X, Page
no. 215
9. Trace metals in waste material
especially slag.
Not Applicable. -
Project Specific TOR
1. P.H. shall be conducted by the
Rajasthan Pollution Control Board as
per the generic TOR.
Public Hearing for the proposed expansion project
was conducted on 20th April, 2016 at 3:00 PM at
Office, Sub Divisional Officer, Jaitaran, District -
Chapter - VII,
Section 7.2, Page
no. 151
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
ToR Compliance
M/s. Shree Cement Ltd. 27 JM EnviroNet Pvt. Ltd.
ToR Point
No.ToR Point Compliance
Reference in Final
EIA/EMP Report
Pali (Rajasthan).
Details of the same have been incorporated in this
EIA/EMP Report.
2. Capacity of the unit along with number
of the units should be mentioned in
the line diagram.
Line diagram showing capacity and number of
each unit has been incorporated in this EIA/EMP
Report.
Chapter - I, Figure
1.1, Page no. 33
3. Use of hazardous waste in the cement
plant.
Details regarding use of hazardous waste in
cement plant have been incorporated in this
EIA/EMP Report.
Chapter - X, Page
no. 218
4. Certified compliance report of RO visit
should be submitted along with the
EIA/EMP report.
Status of compliance of the conditions stipulated
in the EC for the existing capacity of the plant duly
certified by RO, MoEFCC has been enclosed as
Annexure - 1 (b) along with this EIA/EMP Report.
Annexure - 1 (b),
Page no. 294
5. EIA should be prepared for the impact
of total 10.4 to 15.0.
EIA report has been prepared for the impact of
total 10.4 to 15.0 Million TPA.
Chapter - IV,
Section 4.4.2.2,
Page no. 125
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 28 JM EnviroNet Pvt. Ltd.
CHAPTER-I
INTRODUCTION
1.1 PURPOSE OF THE REPORT
As per EIA Notification dated 14th
Sept., 2006, as amended from time to time; it is mandatory to
have Environmental Clearance for any new industry or the expansion / modernization of the
existing industry from Ministry of Environment, Forest& Climate Change, Government of India,
New Delhi / SEIAA. For this, Environment Impact Assessment (EIA) has to be conducted as per
guidelines given by MoEFCC, New Delhi.
The purpose of this EIA report is to provide a coherent statement after analysis of allpotential
impacts due to proposed expansion project and the measures that should be taken to eliminate
and mitigate them. It contains essential information for:
� The proponent to implement the proposal in an environmentally and socially responsible
way;
� The responsible authority to make an informed decision on the proposal, including the terms
and conditions that must be attached to an approval or authorization; and
� The public to understand the proposal and its likely impacts on people and the environment.
1.2 IDENTIFICATION OF PROJECT AND PROJECT PROPONENT
1.2.1 Introduction of the Project Proponent
Company Profile
Shree Cement Limited (SCL) is the largest producer of cement in Northern India and is ranked
among the top five cement groups in the country with a production capacity of 25.6 Million TPA. It
started its operations in 1985 with 0.6 Million Tonnes capacity at Bangur Nagar, Beawar in
Rajasthan and has rapidly expanded its operations to reach the present production capacity of
25.6 Million TPA. The principal promoter of the company is Bangur Group, which is a respected
business house of I ndia.
Cement Manufacturing Facilities
The company has its manufacturing operations at Beawar and Ras in Rajasthan and Bhatapara in
Chattisgarh. It has split grinding units at seven locations viz. Khushkhera, Suratgarh, Jobner in
Rajasthan, Roorkee in Uttrakhand, Aurangabad in Bihar, Bulandshahr in Uttar Pradesh and Panipat
in Haryana, taking the total cement capacity of the company to 25.6 Million TPA. Total Thermal
Power Plants Capacity of the Company is 612 MW (including 111 MW WHRS).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 29 JM EnviroNet Pvt. Ltd.
Products
The company pursues multi-brand portfolio strategy which consists of three offers viz. Shree Ultra
Jung Rodhak Cement, Bangur Cement and Rockstrong Cement.
Corporate Sustainability
Shree Cement Ltd. always strives to sustain its reputation as a respected corporate citizen. It
acknowledges that its operations have multiple impacts on the environment and communities in
which it operates. It has embedded the sustainability principles in all its activities and pursues this
as an integral part of its business operations. Shree has been on a continuous drive for ‘greening’
of its processes so that its operations put the minimum burden on the earth's finite resources. The
installation of company’s waste heat recovery plants (Green Power Plants) are steps in this
direction.
Service towards the community
Shree Cement has displayed good corporate citizenship by providing assistance and funds for
natural calamities, education programmes and institutions, AIDS awareness, preventive medicine,
eye camps, drinking water projects, among others. The company engages in a continuous
dialogue with community leaders.
Recognitions
� First Indian Cement Company to join Cement Sustainability Initiative of WBCSD.
� First Indian Cement Company to be Member of World Economic Forum.
� First company in the World to use innovative techniques to utilize 100% Petcoke in its
operations.
� First Cement Company of the World to fetch Certified Emission Reductions (CER’s) on its
Clean Development Mechanism project “Optimal Utilization of Clinker”.
� First Indian cement company to issue Corporate Sustainability Report following the highest
level “A+” for reporting triple bottom line performance
� New World Sustainability Champions by the World Economic Forum (WEF)
� Government of India recognized in-house R&D centre.
1.2.2 Identification of the Project
A. Details reg. the Existing Project
M/s. Shree Cement Limited (SCL) is having an existing Integrated Cement Plant - Clinker (Unit - III
to X), Cement, Captive Power Plant, WHRB, Synthetic Gypsum Unitand D.G Set near Village: Ras,
Tehsil: Jaitaran, District: Pali, Rajasthan.SCL has obtained Environmental Clearance for Integrated
Cement Plant - Clinker (11.2 Million TPA), Cement (8.8 Million TPA), Captive Power Plant (180 MW)
andWHRB (66 MW) near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan) from MoEFCC, New
Delhi vide letter no. J-11011/343/2012-IA-II(I) dated 10th
September, 2015.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 30 JM EnviroNet Pvt. Ltd.
Details of different units andtheir production capacity at SCL plant premises along with the
necessary clearances are given in Table - 1.1:
Table - 1.1
Existing Clearances / Consents at RasPlant of SCL
S. No. Particular Details
1. Present Capacity Clinker (11.2 Million TPA), Cement (8.8 Million TPA), Captive Power Plant
(180 MW) and WHRB (66 MW)
2. Environmental Clearance
(issued by MoEFCC, New Delhi)
Particular MoEF Letter No. & Date
Ras Cement Plant (Clinker - 1.5 MTPA, 1.61
MTPA of OPC or 2.59 MTPA of PPC)
J-11011/107/2003-IA-II(I)
dated 03rd
March, 2004
Cement Plant (Clinker - 2.0 MTPA, 2.15 MTPA
OPC / 3.44 MTPA PPC)
J-11011/301/2005-IA-
II(I)dated 04th
April,
2006
Integrated Cement Plant - Clinker (6.3 MTPA),
Cement (9.8 MTPA - 5 Units), CPP {80 MW (4 x
20 MW)} and Limestone Mine (Nimbeti Mine -
750.0 ha - 11.4 MTPA)
J-11011/1174/2007-IA-
II(I)dated 02nd
April,
2008
Integrated Cement Plant (Clinker, 6.0 to 8.0
MTPA & reduction in Cement production, 9.8
to 8.8 MTPA), CPP (80 to 180 MW), WHRS (25
to 35 MW) and Limestone Mine (Nimbeti Mine,
750.0 ha - 11.4 to 14.4 MTPA)
J-11011/981/2008-IA-
II(I)dated 27th
February,
2010
Expansion of Integrated Cement Plant - Clinker
(8.0 to 10.4 MTPA), Cement (8.8 MTPA), CPP
(180 MW), WHRS (35 to 45 MW)
J-11011/400/2010-IA-II (I)
dated 27th
August, 2012
Expansion of Integrated Cement Plant (Clinker
from 10.4 MMTPA to 11.2 MMTPA)
J-11011/343/2012-IA-II (I)
dated 10th
Sept., 2015
3. Consent to Operate
(issued by RSPCB)
Particular Unit / Capacity RSPCB Letter No. & Date
Clinker Unit - III (3,700 TPD)
F (Tech)/Pali(Jaitaran)/2(1)/2008-
2009/7814-7817 dated 16th
Jan., 2014
Unit - IV (1.20 MTPA) F(Tech)/Pali(Jaitaran)/2(1)/2008-
2009/6481-6483 dated 03rd
Dec., 2014
Unit - V (1.20 MTPA) F (Tech)/Pali(Jaitaran)/2(1)/2008-
2009/6489-6493 dated 03rd
Dec., 2014
Unit - VI (3,700 TPD) F (Tech)/Pali(Jaitaran)/2(1)/2008-
2009/7821-7824 dated 16th
Jan., 2014
Unit - VII (3,700 TPD) F (Tech)/Pali(Jaitaran)/2(1)/2008-
2009/7825-7828 dated 16th
Jan., 2014
Unit-VIII (1.20 MTPA) F (Tech)/Pali(Jaitaran)/2(1)/2008-
2009/5214-5217 dated 18th
Sept., 2014
Unit - IX (5,500 TPD) F (CPM)/Pali(Jaitaran)/1024(1)/ 2013-
2014/ 8058-8061 dated 16th
Feb. 2016
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 31 JM EnviroNet Pvt. Ltd.
S. No. Particular Details
Clinker Unit - X (1.6 MTPA) F (CPM)/Pali(Jaitaran)/1024(1)/ 2013-
2014/ 8062-8065 dated 16th
Feb., 2016
Cement
Unit- III (7,000 TPD) F (Tech)/Pali(Jaitaran)/2(1)/2008-
2009/7814-7817 dated 16th
Jan., 2014
Unit- IV (2.20 MTPA) F (Tech)/Pali (Jaitaran)/2(1)/2008-
2009/6481-6483 dated 03rd
Dec., 2014
Ras New Cement
Unit (4.40 MTPA)
F (CPM)/Pali (Jaitaran)/1024(1)/ 2013-
2014/7634-7636 dated 08th
Jan., 2014
CPP 180 MW F (Tech)/Pali (Jaitaran)/2(1)/2008-
2009/6382-6385 dated 27th
Nov., 2014 WHRB 68 MW
DG Set 1000 KVA
Synthetic
Gypsum 1560 TPD
F(CPM)/Pali (Jaitaran)/1024(1)/2013-
2014/6167-6169 dated 10th
Nov., 2014
Compliance of the conditions stipulated in EC / CTE / CTO has been submitted to the concerned
authorities on regular basis.
Source: Pre-feasibility Report
B. Project Proposal
Shree Cement Ltd. (SCL)is now proposing for an expansion of Integrated Cement Plant - Clinker
(11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW),CPP (180 MW),
Synthetic Gypsum Unit (1560 TPD) and DG Sets (1000 to 2000 KVA)near Village: Ras, Tehsil:
Jaitaran, District: Pali (Rajasthan).
The existing, additional and the total plant production capacities after the proposed expansion
are given in Table - 1.2 and Line diagram showing capacity and number of each unit has been given
as Figure - 1.1.
Table - 1.2
Project Proposal
S. No. Particular Unit Existing Capacity Additional
Capacity
Total Capacity
after expansion
1. Clinker (Million TPA)
Unit - III to Unit - VIII 6 Units x 1.2 = 7.2 Nil 7.2
Unit - IX 2.0 0.6 2.6
Unit - X 2.0 0.6 2.6
Unit - XI (Proposed) Nil 2.6 2.6
2. Cement (Million TPA)
Unit - III & IV
(Ball Mill with RP) 2 Units x 2.2 = 4.4 Nil 4.4
Ras New Cement Unit
(VRM + Ball Mill) 4.4 Nil 4.4
Proposed Cement Unit
(VRM + Ball Mill) Nil 4.4 4.4
3. Captive Power Plant(MW) - 180 Nil 180
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 32 JM EnviroNet Pvt. Ltd.
S. No. Particular Unit Existing Capacity Additional
Capacity
Total Capacity
after expansion
4. Waste Heat Recovery
Power Generation (MW) - 68 22 90
5. Synthetic Gypsum Unit
(TPD) - 1560 Nil 1560
6. DG Sets (KVA) - 1000 1000 2000
7. Township Bhagatpura Township
40 ha area and
Super Built-up area
is 136766 sq. m
Nil
40 ha area and
Super Built-up area
is 136766 sq. m
Source: Pre-feasibility Report
Activities to be carried out for Further Expansion of Unit - IX andUnit - X
S.
No.
Required modifications in existing
2.0 Million TPA each Clinker unit
Proposed clinker production @
2.6 Million TPA Clinker by each
unit
Remark
Cost
(Rs. in
Crores)
1 Increase of Kiln inlet riser area
from 7.03 m2 to 7.88 m2 (12%) Expected increase in clinker
production capacity by 0.6
MTPA.
(Increase of each kiln capacity
from 7000 TPD to 8500 TPD)
Increase in kiln main firing from
present 30 % to about 40% with
maintaining kiln inlet air velocity
between 17-19 mps
3.0
2 Increase kiln speed from 4.5-5.3
rpm Design at 5.5 rpm 0.0
3 Enlargement of clinker cooler area
from 135 m2 to 150 m2
Maintaining 55-57 TPD/m2 clinker
cooler loading. 1.5
4 Installation of additional chamber
for Reverse Air Bag House (RABH)
Additional chamber will be
added.
To achieving PM emission level
below 30 mg/Nm3
0.50
Time of Completion of the project: Approx. 2 months for upgradation of unit-IX & X and minimum 38 Months
for unit –XI. Cement mill and clinker unit may be installed in phased manner as per market scenario. Details of
activities along with time required for completion of the project is given in Table - 1.3:
Table - 1.3
Time of Completion of the Project
S. No. Activity Time (Months)
1. Up gradation of Unit - IX & X 2
2. Appointment of Consultant, Basic engineering and issue of tender
enquiries and main machinery order placement for unit-XI 6
3. Civil construction 20
4. Fabrication work 20
5. Electrical & Instrument Erection 10
6. Refractory works 10
7. Trial runs and Commissioning 2
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA )
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 33 JM EnviroNet Pvt. Ltd.
Figure1.1: Line Diagram showing capacity of each unit along with number of units
Local Market
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 34 JM EnviroNet Pvt. Ltd.
C. Screening Category
As per EIA Notification dated 14th
Sept., 2006, as amended from time to time; the project falls
under Category “A”, Project or Activity ‘3(b)’.
1.3 BRIEF DESCRIPTION OF NATURE, SIZE, LOCATION OF THE PROJECT AND ITS IMPORTANCE TO
THE COUNTRY, REGION
1.3.1 Brief Descr iption of Nature, Size and Location of Project
Brief Description of Nature, Size and Location of the Project is given in Table - 1.4.
Table- 1.4
S. NO. PARTICULARS DETAILS
A. Nature and Size of the Project
Proposed Expansion of Integrated Cement Plant - Clinker (11.2
to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS
(68 to 90 MW), CPP (180 MW) along with Synthetic Gypsum
Unit (1560 TPD) and DG Sets (1000 to 2000 KVA)
B. Location Details
1. Village Ras
2. Tehsil Jaitaran
3. District Pali
4. State Rajasthan
C. Geographical Extent of the Plant Site
5. Latitude 26o15’ 31.6” to 26
o 16’ 45.3” N
6. Longitude 74o
10’ 53” to 74o
11’ 48.1” E
7. Corner Co-ordinates of the Plant site
A. 26o
15’ 35.6” N - 74o10’ 53” E
B. 26o
15’ 31.6” N - 74o 11’ 11.4” E
C. 26o
15’ 44” N - 74o 11’ 36.2” E
D. 26o
16’ 17.8” N - 74o 11’ 48.1” E
E. 26o
16’ 28” N - 74o 11’ 27.3” E
F. 26o
16’ 45.3” N - 74o 11’ 13.1” E
8. ToposheetNo. 45 J/3, 45 J/4, 45 J/7 and 45 J/8
� Location Map of the Plant Site has been shown in Figure - 1.2
� Map showing C orner Co-ordinates of the Plant site has been shown in Figure - 1.3
� Google Earth downloaded map of the plant site has been shown in Figure - 1.4
D. Area Details
1. Plant area
Total plant area is 231.54 ha (which includes 187.56 ha existing
plant area and 43.98 ha additional area within plant boundary);
72.7 ha area is also available outside the plant boundary for
future use.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 35 JM EnviroNet Pvt. Ltd.
S. NO. PARTICULARS DETAILS
2. Greenbelt / Plantation area
� 63.8 ha (34% of the total existing plant area i.e. 187.5 ha)has
already been developed under greenbelt/ Plantation
� Additional 14.5 ha will be further developed for this
expansion project.
3. Township Area
Area of the township near village Bagatpura is 40 ha, out of
which 14.5 ha (i.e. 36%) is developed under greenbelt /
plantation area.
4. Corner Coordinates of Township
1. 26o15’41.7’’N - 74
o13’23.5’’
2. 26o15’36.5’’ N - 74
o13’34.2’’
3. 26o16’06.7’’ N - 74
o13’50’’
4. 26o16’10.3’’ N - 74
o13’35.4’’
E. Environmental Setting Details (with approximate aerial distance and direction from the plant site)
1. Nearest Town Ras (3.0 Km in N direction)
2. Nearest City Beawar (21.0 Km in SE direction)
3. Nearest National / State Highway � NH-14 (19.5Kmin SE direction)
� SH- 39 (1.5Km in NE direction)
4. Nearest Railway station Beawar (21.0 Km in SE direction)
5. Nearest Airport Jodhpur (113 Km in W direction)
6. National Parks, Wildlife Sanctuaries,
Biosphere Reserves, within 10 km radius
No National Park, Wildlife Sanctuary, Biosphere Reserve, exists
within 10 km radius of the plant site
7. Reserved / Protected Forests within 10
km radius
� Reserved Forest (~5.0Km in SSE direction)
� Protected Forest (~9.9 Km in SE direction)
8. River/Water Body within 10 km radius � Lilri River (Seasonal) (1.5 Km in North direction)
� Sukri River (8.0 Km in SSW direction).
� Environmental Setting Map of the 10 km radius study area has been shown in Figure - 1.5
9. Seismic Zone Zone-II [as per IS 1893 (Part-I): 2002]
10. Critically Polluted Area as per CEPI -
CPCB
No critically polluted area declared under CEPI as per MoEFCC
Circular dated 15.03.2010 exists within 15 km radius study area
� Google Map showing the distance of Plant site from Critically Polluted Areas identified in Pali District (Rajasthan)
alongwith Letter received from RSPCB reg. CEPI has been enclosed as Annexure -11.
F. Cost details
1. Total Cost of the Project Rs. 755 Crores
2. Cost for Environmental Protection
Measures
� Capital Cost - Rs. 51.0 Crores
� Recurring Cost - Rs. 1.0 Crores / annum
Source: Pre-feasibility Report
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 36 JM EnviroNet Pvt. Ltd.
1.3.2 Location Map
Figure1.2: Location Map
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA )
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 37 JM EnviroNet Pvt. Ltd.
Figure 1.3: Map showing Corner Co-ordinates of the Plant Site
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA )
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 38 JM EnviroNet Pvt. Ltd.
Figure1.4: Google Earth Downloaded Map of the Plant Site
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA )
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 39 JM EnviroNet Pvt. Ltd.
Figure 1.5: Map showing Environmental Settings of the 10 km radius study area
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 40 JM EnviroNet Pvt. Ltd.
1.3.3 Site Selection
Proposed expansion by SCL will be done on additional available area within the existing plant
premises.The site for the existing plant was finalized considering the ideal location for the
industries. Following factors were considered while selecting the site:
� Suitable source of raw material.
� Nearness to rail route & SH - 39 &NH-14 makes it easier to transport raw materials and final
product both clinker and cement at market.
� Location in rural area ensures adequate availability of ma npower at marginally lower rates,
compared to metro cities of India.
� Availability of existing facilities like storage, infrastructure, transportation, administration etc.
Photographs of the existing plant and proposed site for Unit XI and Cement Mill within plant
premises have been shown in Figure 1.6 (a) and (b) below:
Figure 1.6 (a): Photographs of the Existing Plant
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 41 JM EnviroNet Pvt. Ltd.
Figure 1.6 (b): Photograph showing s ite for Unit XI & Cement Millwithin Existing Plant Premises
1.3.4 Approach to the Plant Site
M/s. Shree Cement Limited (SCL) is having an existing Integrated Cement Plant - Clinker (Unit - III
to X), Cement, Captive Power Plant, WHRB, Synthetic Gypsum Unit and D.G Set near Village: Ras,
Tehsil: Jaitaran, District: Pali, Rajasthan. The plant site is well connected with NH - 14 (~ 19.5 Km in
SE direction) and SH - 39 (~1.5 Km in NE direction). Nearest Railway Station is Beawar Railway
Station which is about 21 km in SE direction from the plant site. Nearest Airport is at Jodhpur
which is approx. 113 km in West direction from the plant site.
1.3.5 Importance to the Country and Region
Driven by a booming housing sector, global demand and increased activity in infrastructure
development such as state and national highways; the cement industry has outpaced itself,
ramping up the production capacity. Going forward, these demand drivers will take the cement
demand to new heights in the next five years. Thus, this proposed expansion project is of prime
importance to country and local region.
National Importance
The Indian Cement Industry is the second largest producer of cement in the world after China
accounting for about 8% of the total global production. Cement is a cyclical commodity with a high
correlation with GDP. The housing sector is the biggest demand driver of cement, accounting for
about 67% of the total consumption. The other major consumers of cement include infrastructure
(13%), commercial construction (11%) and industrial construction (9%).Cement production increased
at a compound annual growth rate (CAGR) of 9.7% to 272 Million Tonnes (MT) over FY06-13. The
domestic cement consumption is expected to increase at a CAGR of 10.2% during FY11-17.
The proposed expansion project is also expected to generate additional direct and indirect
employment opportunities for people and give State exchequer in the form of share of Central
Excise duty, Royalty on vendors and VAT annually.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - I of Final EIA / EMP Report
M/s. Shree Cement Ltd. 42 JM EnviroNet Pvt. Ltd.
Regional Importance
With a capacity of over 13 Million Tonnes Per Annum, Rajastha n accounts for over 15% of India's
cement production. With the domestic demand for cement expected to grow at 8-9 per cent
annually. Under Rajasthan Urban Infrastructure Development Project (RUIDP) Phase I large
amount of construction activity is targeted.Increasing infrastructure demand and rapid upcoming
developmental activities have resulted in the healthy consumption of the cement in the region.
Both private and governmental developmental activities including construction of highways,
roads, flyover, bridges, building apartments and townships are playing a key role in increasing
demand of cement. Thus, to meet the increasing demand, the enhancement in production
capacity is required.
In addition to above, disposal of fly ash is a n environmental concern which is faced by state
owned and thermal power plants. Cement grinding can consume up to thirty percent of fly ash
produced in the nearby power plants and thus, reduce environmental concern. There is also well
developed presence of supply chain and marketing channels. Presence of lignite for the power
development for captive consumption will too reduce the bargain power of the developer.
Hence, the proposed expansion project by the company is required to sustain SCL's current
market share in line with the market growth, ensuring supply on demand and development of this
area, which will ultimately contribute to rapid economic growth of the country.
1.4 SCOPE OF STUDY
The disciplines covered under the study are prerequisite information of the proposed expansion
site, manufacturing / operation details, production details, waste generation and its proper
disposal, impacts and management plans. This report contains performance testing data of
ambient air quality monitoring as well as the ecological studies, noise environment, socio-
economic study carried out during Summer Sea son i.e. March to May, 2015.
Application (Form-1/ToR and Pre-Feasibility Report) for obtaining Environmental Clearance for this
expansion project was submittedto MoEFCC, New Delhi on24th
Jan., 2015.
First Technical Presentation (for ToR approval) for the same was held before EAC (I) on 11th
February, 2015.
ToRLetter was issued by MoEFCC, New Delhi vide letter no. J-11011/343/2012-IA II (I) dated 10th
Feb.,
2016 andcopy of the same has been incorporated in this EIA/EMP Report,page no. 1 to 11.
The reply/clarification of all the points suggested in ToRletter has been incorporated in
thisEIA/EMP Report at page no. 12 to 27.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 43 JM EnviroNet Pvt. Ltd.
CHAPTER - II
PROJECT DESCRIPTION
2.1 TYPE OF THE PROJECT
M/s. Shree Cement Ltd. has obtained Environmental Clearance for existing Integrated Cement
Plant having Clinker production capacity of 11.2 MTPA, Cement production capacity of 8.8 MTPA,
WHRS of 66 MW capacity, CPP of capacity 180 MW near Village: Ras, along with township near
Village Bagatpura, Tehsil: Jaitaran, District: Pali (Rajasthan).
The company is now proposing an expansion of Integrated Cement Plant - Clinker (11.2 to 15.0
Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic
Gypsum (1560 TPD) and DG Sets (1000 to 2000 KVA).
As per EIA Notification dated 14th Sept., 2006, as amended from time to time; the project falls
under Category A , Project or Activity 3(b) and therefore, requires Environmental Clearance
from MoEFCC, New Delhi.
2.2 NEED FOR THE PROJECT
Cement manufacturing Industries are one of the important sectors of the Indian Economy. The
sector has experienced phenomenal growth especially after the decontrol regime from 1999 and
greater thrust by Government on Infrastructure development and spurt in housing construction
sector has led to increased demand for cement. The cement market in India is expected to grow
at a compound annual growth rate (CAGR) of 8.96 percent during the period 2014-2019.
In order to meet the increasing demand, most cement plants are making efforts to achieve higher
production levels, at times by stretching the existing production facilities and by adding additional
capacities.
Looking to the increasing demand of cement, Shree Cement Ltd. has proposed expansion of
Integrated Cement Plant at one of its units near Village: Ras, Tehsil: Jaitaran, District: Pali
(Rajasthan).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 44 JM EnviroNet Pvt. Ltd.
2.3 LOCATION
Location details have been incorporated in Chapter - I of this Final EIA/EMP Report, Table - 1.4 and
Figure - 1.2, Page no. 34 and 36, respectively.
2.4 REQUIREMENTS FOR THE PROJECT
2.4.1 Raw Materials Requirement
Details regarding quantity of raw materials required, their source along with distance and mode of
transportation for proposed expansion project are given in Table- 2.1.
Table- 2.1
Raw Material Requirement for Clinkerization and CPP
S.
No.
Name of Raw
Material
Required Quantity (MTPA)
SourceDistance& Mode of
TransportationExisting Additional
Total after
proposed
expansion
1.
Limestone
(Clinker Units and
CPP)
16.8 5.7 22.5 Captive Limestone MineAdjacent to the plant,
Conveyor belts
2.
Laterite
0.504 0.171 0.675
BhilwaraBhilwara - 190 kms,
Chhitorgarh (Raj) - 200
kms
Rail and RoadLead Zinc Slag
Chhitorgarh (Raj) and
other nearby sources
3.
Gypsum
(Mineral, Synthetic,
Chemical and
Imported)
0.44 0.22 0.66
Bikaner, Nagaur (Raj),
SCL Units, Gujarat,
other sourcesand Other
countries
Bikaner - 425 kms, Nagaur
(Raj) - 150 kms
Rail and Road
4. Fly Ash 3.0 1.5 4.5
STPS, Suratgarh; KTPS
Kota; Chabra and other
power plants and other
nearby sources
STPS, Suratgarh - 450
kms; KTPS Kota - 255 kms,
Chabra - 425 kms
Road
Source: Pre-feasibility Report
Table - 2.2
Raw Materials Requirement for Synthetic Gypsum Unit
S.
No.Name of Raw Material
Existing Quantity
(MTPA)Source
Distance and Mode of
Transportation
1. H2SO4 98% 0.22 Local Market By road
2. Limestone 0.33 Captive limestone mine Covered Conveyor Belt
Source: Pre-feasibility Report
2.4.2 Fuel Requirement
Details regarding quantity of fuel required, their source along with distance and mode of
transportation for proposed expansion project are given in Table - 2.3.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 45 JM EnviroNet Pvt. Ltd.
Table- 2.3
Fuel Requirement
S.
No.Name of Fuel
Required Quantity (MTPA)
Source of
Materials
Distanceand
Mode of
Transportation
Calorific
value
(Kcal./kg)
% Ash%
SulphurExisting Additional
Total after
proposed
expansion
1.
Clinker units-
Petcoke / Indian
and Imported Coal
/ Lignite
1.68/3.36/3.3
6
0.57/1.14/1.14
2.25/4.5/2.92
Reliance, IOCL,
Essar and
other
Petrochemical
Refineries,
USA, Swiss,
Saudi Arabia,
Rajasthan etc
Reliance - 750
kms, IOCL-520
kms), Essar -
750 kms and
Swiss, Saudi
Arabia (Kandla
Port) - 650 kms
Rail and Road
7936 /
3890
/6100
0.8 /
9.6 /
41.7
5.5 / 3.5
/0.5
2.
CPP-
Petcoke / Indian
and Imported Coal
/ Lignite
0.5/ 1.0/0.65
Nil0.5/ 1.0/
0.65
Source: Pre-feasibility Report
Mass Balance Diagram
Mass Balance Diagram for the Proposed Expansion of Integrated Cement Project for
manufacturing of OPC and PPC is shown in Figure - 2.1.
Figure 2.1: Mass Balance Diagram
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 46 JM EnviroNet Pvt. Ltd.
2.4.3 Other Basic Requirements
Other basic requirements for the proposed expansion project are given in Table - 2.4; details of
which are given in sub - sections below:
Table - 2.4
Basic Requirements for the Project
S. No. Particular Total Requirement Source
1. Water (m3/day) 3500 Ground Water
2. Power (MW) 158.9Captive Power Plant, WHRB, Grid and D.G
Sets (for backup)
3. ManpowerRegular - 1460
Contractual - 1951
Unskilled/ semi-skilled manpower from local
area and skilled from outside/local.
Source: Pre-feasibility Report
2.4.3.1 Water Requirement
The water requirement for existing Integrated Cement Plant is 2750 KLD. Additional 750 KLD will
be required for the proposed expansion project; hence, the total water requirement after the
proposed expansion project will be 3500 KLD; which will be sourced from Ground water.
Break-up of the water requirement is given in Table - 2.5 and Water Balance Diagram is given in
Figure - 2.2.
Status of Approval: Permission for withdrawal of ground water for 4000 KLD has already been
obtained from CGWA vide letter no. 21-4(12)/ WR/ CGWA/ 2005-616 dated 23rd May, 2011, 21-4(12)/
WR/ CGWA/ 2005-1220 dated 12th July, 2013 and 21-4(12-B)/ WR/ CGWA/ 2005-255 dated 11th
February, 2014.
Copy of the same has been enclosed as Annexure 2 along with this EIA / EMP Report.
Table - 2.5
Break- up of Water Requirement
(Unit: KLD)
UnitWater Consumption Domestic Sewage
Water GenerationTrade effluent
Industrial Domestic
U-III 150 20 15 Nil
U-IV 150 20 15 Nil
U-V 100 20 15 Nil
U-VI 100 20 15 Nil
U-VII 100 20 15 Nil
U-VIII 100 20 15 Nil
U-IX 225 20 15 Nil
U-X 225 20 15 Nil
Ras New Cement Unit 150 20 15 Nil
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 47 JM EnviroNet Pvt. Ltd.
UnitWater Consumption Domestic Sewage
Water GenerationTrade effluent
Industrial Domestic
Power Generation 800 20 15 256
Residential Colony 0 335 270 Nil
Miscellaneous 115 Nil Nil Nil
Total Existing 2215 535 420 256
Grand Total Existing Water
Requirement2750
Proposed Expansion 530 50 30 44
Miscellaneous 170 Nil Nil Nil
Total Water Requirement for
proposed Expansion750
Total After Expansion 2915 585 450 300
Total Water Requirement
after proposed Expansion3500
Industrial Consumption
Domestic Water Trade EffluentSynthetic Gypsum
Mine Pit / Ground
WaterCPP reject
346 256 Nil35
(recycled in process)
Note:
Total Ground Water 3500 KLD
Total Mine Pit + Ground Water 3846 KLD
Source: Pre-feasibility Report
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 48 JM EnviroNet Pvt. Ltd.
Water Balance Diagram
Figure 2.2: Water Balance Diagram
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 49 JM EnviroNet Pvt. Ltd.
2.4.3.2 Power Requirement
The existing power requirement for the Cement Plant is 110.6 MW and additional power required
for the Proposed Expansion Project will be 48.3 MW. Thus, the total power requirement after
proposed expansion will be around 158.9 MW.
Details reg. Power Requirement is given in Table - 2.6.
Source of Power: Captive Power Plant, WHRB, Grid and D.G Sets (for backup).
Table- 2.6
Power Requirement
S. No. Power Consumption Cement Plant Colony Total
1. Existing 107.4 3.2 110.6
2. Additional Proposed 48.3 Nil 48.3
Total Power consumption 155.7 3.2 158.9
Source: Pre-feasibility Report
Energy Balance
Energy balance after proposed expansion is given below:
S.
No.Description
Capacity /
annum
(TPA)
Working
DayTPD
Running
HrsTPH
Kwh /
Tonne
Power
KWh/
annum
Kwh
/hr.
1. Raw Mill -XI 3900000 338 11550 21 550 23 89700000 7475
2. Kiln & Cooler-XI 2600000 306 8500 24 354 25 65000000 8125
3. Coal Mill -XI 260000 340 765 17 45 5 1300000 1625
4. Proposed Limestone Crusher 3900000 310 12600 9 1400 2 7800000 650
5.Proposed New Cement mill &
Packing Plant4400000 293 15000 24 625 30 132000000 18750
6. Increase of Raw mill-IX capacity 900000 333 2700 21 113 23 20700000 1725
7. Increase of Kiln-IX capacity 600000 333 1800 24 75 25 15000000 1875
8.Increase of Coal Mill - IX
capacity60000 333 180 17 45 5 300000 375
9.Increase of existing limestone
crusher production for unit-IX900000 333 2700 9 1400 2 1800000 150
10. Increase of Raw mill-X capacity 900000 333 2700 21 112.5 23 20700000 1725
11. Increase of Kiln-X capacity 600000 333 1800 24 75 25 15000000 1875
12. Increase of Coal Mill - X capacity 60000 333 180 17 45 5 300000 375
13.Increase of existing limestone
crusher production for unit-X900000 333 2700 9 1400 2 1800000 150
14.Additional Ball Mill with
Synthetic Gypsum Unit1080000 300 3600 24 150 23 24840000 3450
Total Power 396240000 48325
2.4.3.3 Manpower Requirement
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 50 JM EnviroNet Pvt. Ltd.
Existing manpower (regular) for the Integrated Cement Plant is 1360. Additional manpower of 100
is required for the proposed expansion project. Thus, total manpower requirement after
proposed expansion project will be 1460.
Source: Unskilled/ semi-skilled manpower from local area and skilled from outside/local.
Details regarding manpower requirement is given in Table - 2.7.
Table-2.7
Manpower Requirement
S.No. Particular Regular Contractual
1. Existing 1360 1926
2. Proposed 100 25
Total 1460 1951
2.5 LAND DETAILS
Total plant area is 231.54 ha (which includes 187.56 ha existing plant area and 43.98 ha additional
area within plant boundary); 72.7 ha area is also available outside the plant boundary for future
use and all the land is under possession of M/s. Shree Cement Ltd.
Out of the total existing plant area i.e. 187.5 ha, 63.8 ha (~ 34% of the total existing plant area) has
been already developed under greenbelt/ plantation and additional 14.5 ha will be further
developed for this expansion project. Besides this, 33% (i.e. 24 ha) of the area available outside the
plant boundary (72.7 ha) will also be developed under greenbelt / plantation, whenever used in
future.
Total existing colony area is 40 ha near village Bagatpura, out of which 14.5 ha will be developed
under greenbelt/ plantation.
Area details are given in Table - 2.8.
Table - 2.8
Area Details
S.No. Particular Area (ha)
1. Existing Plant Area 187.56
2. Area required for proposed Unit-XI and Cement Mill 21.35
3. Additional area available within plant boundary 22.6
Total Area After Expansion 231.54
4. Additional Land available outside the plant boundary for future use 72.7
Total Plant Area 304.2
5. Existing Greenbelt / Plantation area (34% of total plant area) 63.8
6. Greenbelt / Plantation area to be developed for this expansion project 14.5
7.Greenbelt / Plantation area to be developed on the area available outside
the plant boundary whenever used in future24
8. Existing colony near village Bagatpura 40
Source: Pre-feasibility Report
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 51 JM EnviroNet Pvt. Ltd.
2.5.1 Plant Layout
The features of the plant layout are as follows:
The major utilities and service facilities are centrally located;
Sufficient space has been provided for ease of operation and maintenance;
Outward movements of materials from customers/suppliers have been segregated from
internal plant traffic; and
Safety requirements have been kept in mind while locating the workshops and vehicular
movement inside the plant.
Plant Layout is shown in Figure 2.3.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 52 JM EnviroNet Pvt. Ltd.
Figure 2.3: Plant Layout
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 53 JM EnviroNet Pvt. Ltd.
2.6 MANUFACTURING PROCESS DESCRIPTION
2.6.1 Cement Plant
Process Description
Cement Plant is based on Dry Process Technology for Cement manufacturing with Pre-Heater and
Pre- Calciner Technology. The type of cement being manufactured is OPC and PPC.
Cement Manufacturing Process:
The cement manufacturing process largely comprises of the following steps:
Transportation of crushed limestone from the mine site
Pre-blending of crushed limestone by Stacker and Reclaimer
Grinding-cum- Drying of Raw Materials and Coal/ Petcoke in VRM
Homogenization of raw meal in a blending silo
Clinkerisation of the raw meal in a rotary kiln with preheater, calciner and Cooler
Finish Grinding, storage and packing of cement
A. Transportation of Limestone
Limestone is transported from Captive Limestone Mine to the Cement Plant through covered
conveyor belt.
B. Preblending of crushed limestone by Stacker and Reclaimer
The ROM limestone stacked through stacker and reclaimed by reclaimer.
C. Grinding-cum- Drying of Raw Materials and Coal/Petcoke in VRM
Reclaimed limestone with corrective materials (sand, clay, laterite etc.) fed in VRM for grinding.
Hot air of pre-heater used for drying of raw-material.
Coal/ Petcoke is highly abrasive, therefore, its crushing is done usually in a roll crusher. The same
system is proposed to be used. Grinding of coal is done either in air swept ball mill or in vertical
roller mill. Because of saving in energy and better drying capacity VRM is proposed for use. Use of
alternate fuel (hazardous and non-hazardous) will also be considered to use for energy recovery.
These materials will be fed along with coal and per coke.
D. Homogenization of raw meal in a blending silo
The ground raw meal is conveyed to blending-cum-storage silo(s) by mechanical conveyors. The
variation in the quality of raw meal is reduced by using continuous blending silo.
E. Clinkerization of the raw meal in a rotary kiln with preheater, Calciner and Cooler
In cyclone preheater system, an efficient heat transfer takes place to finally dispersed raw
material particles by counter flow with hot gases and grinded raw meal. The preheater is multi
stage cyclone system connected with gas ducts and meal chutes. The raw meal is fed into top
stage gas duct. The material gets separated from gas in cyclones and then travels downwards and
through meal chute is discharged into next lower stage gas duct. In this way, material comes into
contact with high temperature gases and gets preheated and partially calcined and then enters
the pre-calcinator.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 54 JM EnviroNet Pvt. Ltd.
Firing takes place in the calciner and back end of kiln called burning zone. In the calciner,
calcination takes place by firing of pulverized coal and then material is discharged to the kiln. The
feed travels down as the kiln rotates. The chemical reaction completes when the material reaches
the burning zone and cement clinker is formed.
The clinker is discharged from kiln at around 1000 Deg. C temp. and is cooled in a high efficiency
grate cooler. The cooled clinker is then transported to clinker storage silo by a set of Deep Bucket
Conveyor (DBC).
F. Final Grinding, storage and packing of cement:
Similarly, of the raw material grinding system, the grinding of clinker into cement is based on the
following technologies:
Ball mill
Roller press with ball mill.
Vertical roller mill.
In India, cement grinding is conventionally done by ball mill in close circuit using high efficiency
separators. However, due to nearly 25-30 % saving in power, the use of roller press for pre-grinding
followed by grinding in closed circuit ball mill (semi-finish grinding mode) has been used in most of
the recently installed plants. The performance feedback on the installation of VRM for cement
grinding is still awaited and yet to establish as a proven technology. Hence, based on the
performance of Cement Mill, it is proposed to install VRM / Ball mill with roller press or
combination of both VRM and ball mill.
The ground cement is conveyed to cement silos for storage of different types of cement from
where it is extracted and packed in HDPE bags by electronic rotary packing machines and
dispatched to consumers by road and railway. Mechanized loading system for loading of packed
bags on trucks and wagon is envisaged.
Process Flow Diagram of cement manufacturing process is given in Figure - 2.4.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 55 JM EnviroNet Pvt. Ltd.
Figure 2.4: Process Flow Diagram
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 56 JM EnviroNet Pvt. Ltd.
2.6.2 Waste Heat Recovery Power Plant (90 MW)
There is a good amount of waste heat available from the expelled gases of Pre-Heaters (PH) and
Air Quenched Coolers (AQC) of both Units I and II. The main energy used in cement plant consists
of heat energy and electrical energy and about 90% of the total energy is used as heat energy in
clinker burning process. In the clinker burning process, a large amount of heat is consumed for
burning limestone at more than 1450oC to form clinker. From the total heat consumed in the
burning process, around 55% is for burning process and the rest 45% is discharged as sensible heat
through the exhaust gases of Pre-Heater(PH), AQC, radiation and sensible heat carried out by
clinker.
However, around 10% of the heat, extracted from the PHs and AQCs, is used in drying the raw
material and coal while grinding. The rest 35% is generally emitted to the atmosphere as waste
heat. For reutilization of this wasted heat from the exhaust gases of the PH and AQC this Waste
Heat Recovery System is used to generate the electrical power. A typical heat flow in cement
plants with waste heat recovery system is shown below
Considering the above we have decided to install one Waste Heat Recovery Boiler (WHRB) at kiln
Pre-heater and one Waste Heat Recovery Boiler (WHRB) at AQC (Mid tap-off) in each Units. Steam
generated by each unit make combined and fed to steam turbine for Electricity generation. In this
scheme Waste Heat Recovery Boiler (WHRB) at Kiln Pre-heater will be installed. In normal
condition the flue gas from the top of the Pre-heater directly goes to ESP / bag house. Now the
flue gas from the top of the Pre-heater will go to the WHRB and after that it will enter to ESP / Bag
house.
Considering the above SCL have decided to install one Waste Heat Recovery Boiler (WHRB) at kiln
Pre-heater and one Waste Heat Recovery Boiler (WHRB) at AQC (Mid tap-off) in each Units. Steam
generated by each unit make combined and fed to steam turbine for Electricity generation. In this
scheme Waste Heat Recovery Boiler (WHRB) at Kiln Pre-heater will be installed. In normal
condition the flue gas from the top of the Pre-heater directly goes to ESP / bag house. Now the
flue gas from the top of the Pre-heater will go to the WHRB and after that it will enter ESP / Bag
house.
Figure 2.5: Process Flow Sheet of Waste Heat Recovery boiler
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 56 JM EnviroNet Pvt. Ltd.
2.6.2 Waste Heat Recovery Power Plant (90 MW)
There is a good amount of waste heat available from the expelled gases of Pre-Heaters (PH) and
Air Quenched Coolers (AQC) of both Units I and II. The main energy used in cement plant consists
of heat energy and electrical energy and about 90% of the total energy is used as heat energy in
clinker burning process. In the clinker burning process, a large amount of heat is consumed for
burning limestone at more than 1450oC to form clinker. From the total heat consumed in the
burning process, around 55% is for burning process and the rest 45% is discharged as sensible heat
through the exhaust gases of Pre-Heater(PH), AQC, radiation and sensible heat carried out by
clinker.
However, around 10% of the heat, extracted from the PHs and AQCs, is used in drying the raw
material and coal while grinding. The rest 35% is generally emitted to the atmosphere as waste
heat. For reutilization of this wasted heat from the exhaust gases of the PH and AQC this Waste
Heat Recovery System is used to generate the electrical power. A typical heat flow in cement
plants with waste heat recovery system is shown below
Considering the above we have decided to install one Waste Heat Recovery Boiler (WHRB) at kiln
Pre-heater and one Waste Heat Recovery Boiler (WHRB) at AQC (Mid tap-off) in each Units. Steam
generated by each unit make combined and fed to steam turbine for Electricity generation. In this
scheme Waste Heat Recovery Boiler (WHRB) at Kiln Pre-heater will be installed. In normal
condition the flue gas from the top of the Pre-heater directly goes to ESP / bag house. Now the
flue gas from the top of the Pre-heater will go to the WHRB and after that it will enter to ESP / Bag
house.
Considering the above SCL have decided to install one Waste Heat Recovery Boiler (WHRB) at kiln
Pre-heater and one Waste Heat Recovery Boiler (WHRB) at AQC (Mid tap-off) in each Units. Steam
generated by each unit make combined and fed to steam turbine for Electricity generation. In this
scheme Waste Heat Recovery Boiler (WHRB) at Kiln Pre-heater will be installed. In normal
condition the flue gas from the top of the Pre-heater directly goes to ESP / bag house. Now the
flue gas from the top of the Pre-heater will go to the WHRB and after that it will enter ESP / Bag
house.
Figure 2.5: Process Flow Sheet of Waste Heat Recovery boiler
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 56 JM EnviroNet Pvt. Ltd.
2.6.2 Waste Heat Recovery Power Plant (90 MW)
There is a good amount of waste heat available from the expelled gases of Pre-Heaters (PH) and
Air Quenched Coolers (AQC) of both Units I and II. The main energy used in cement plant consists
of heat energy and electrical energy and about 90% of the total energy is used as heat energy in
clinker burning process. In the clinker burning process, a large amount of heat is consumed for
burning limestone at more than 1450oC to form clinker. From the total heat consumed in the
burning process, around 55% is for burning process and the rest 45% is discharged as sensible heat
through the exhaust gases of Pre-Heater(PH), AQC, radiation and sensible heat carried out by
clinker.
However, around 10% of the heat, extracted from the PHs and AQCs, is used in drying the raw
material and coal while grinding. The rest 35% is generally emitted to the atmosphere as waste
heat. For reutilization of this wasted heat from the exhaust gases of the PH and AQC this Waste
Heat Recovery System is used to generate the electrical power. A typical heat flow in cement
plants with waste heat recovery system is shown below
Considering the above we have decided to install one Waste Heat Recovery Boiler (WHRB) at kiln
Pre-heater and one Waste Heat Recovery Boiler (WHRB) at AQC (Mid tap-off) in each Units. Steam
generated by each unit make combined and fed to steam turbine for Electricity generation. In this
scheme Waste Heat Recovery Boiler (WHRB) at Kiln Pre-heater will be installed. In normal
condition the flue gas from the top of the Pre-heater directly goes to ESP / bag house. Now the
flue gas from the top of the Pre-heater will go to the WHRB and after that it will enter to ESP / Bag
house.
Considering the above SCL have decided to install one Waste Heat Recovery Boiler (WHRB) at kiln
Pre-heater and one Waste Heat Recovery Boiler (WHRB) at AQC (Mid tap-off) in each Units. Steam
generated by each unit make combined and fed to steam turbine for Electricity generation. In this
scheme Waste Heat Recovery Boiler (WHRB) at Kiln Pre-heater will be installed. In normal
condition the flue gas from the top of the Pre-heater directly goes to ESP / bag house. Now the
flue gas from the top of the Pre-heater will go to the WHRB and after that it will enter ESP / Bag
house.
Figure 2.5: Process Flow Sheet of Waste Heat Recovery boiler
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 57 JM EnviroNet Pvt. Ltd.
Potential of Waste Heat Power Generation, 90 MW
S.No. Description Unit
Unit 3 to 8 Unit 9 to 11Total
Single Unit Total Single Unit Total
AQC PH AQC PH AQC PH AQC PH AQC PH
1Flue gasflow
Nm³/Hr 100000 165000 600000 990000 250000 400000 750000 1200000
2Inlettemperature
ºC 600 300 600 300 600 300 600 300
3 Specific heat kcal/Nm³c 0.32 0.362 0.32 0.362 0.32 0.362 0.32 0.362
4Exhaust Gastemperature
ºC 80 150 80 150 80 150 80 150
5HeatAvailable
CroreKcal/Hr
1.66 0.90 9.98 5.38 4.16 2.17 12.48 6.52 22.46 11.89
6Total HeatAvailable
CroreKcal/Hr
2.56 15.36 6.33 19.00 34.36
7
Max. Heat(Low GradeEnergy)available
MW 29.77 178.60 73.63 220.88 399.5
8 Generation MW 6.7 40.2 16.6 49.789.9 or90 MW
2.6.3 Synthetic Gypsum Plant
Production capacity: (65 TPH / 1560 TPD) Synthetic gypsum
Process Description
The manufacturing process of Synthetic Gypsum is basically conversion of Limestone Powder by
chemical reaction between Limestone and dilute Sulphuric Acid in definite proportion. The
reactants originally thin slurry set to a solid mass during the reaction. After initial production to
completion of the reaction i.e. Synthetic Gypsum it may take up to 7 days.
RAW
MEAL
FROM
SILO-2 BY
DENSE
PHASE /
BULKER
SCREW CONVEYOR-1 PRE-MIXER
CUTTER
Raw meal, water and Acid are mixed in pre-mixer at a time. Raw meal paste is not formed earlier.
Pre-mixer is a chanmber and all the three materials fall on mixer chamber and mix by paddle.
Time taken in mixer = 10 minutes, Den = 20 minutes and cake is cut and discharge in yard.
DEN
SCHEMATIC PROCESS FLOW SHEET OF SYNTHETIC GYPSUM
SCREW CONVEYOR-2
MIXER
COOLING
TOWER
SCRUBBER
FAN
B
U
C
K
E
T
E
L
E
V
A
T
O
R
HOPPER
ROTARY AIR
LOCK-2
DUST COLLECTOR
FAN
raw
meal
storage
hopper
(100
mt)
ROTARY AIR
LOCK-1
1 2 3 4 5Emegency
Tank
Acid StorrageTank
Unloading Service Tank
Water Tank
Belt conveyer for cement
Plant Feeding
YARD
Weighing Belt Conveyer
Figure 2.6: Process Flow Sheet of Synthetic gypsum
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 58 JM EnviroNet Pvt. Ltd.
Chemistry of Synthetic Gypsum Production
Synthetic Gypsum is made by the reaction of Lime Powder with Sulphuric Acid to convert calcium
oxide to Calcium Sulphate form. This reaction can be represented by the following chemical
reaction, which is the major reaction.
1. Major reaction:
CaCO3 + H2SO4 + H2O CaSO4.2H2O + CO2
The Gypsum (Calcium Sulphate) contains about 7-8% moisture, the chemical impact of acid on
Limestone liberates a large amount of steam, which entrains fine particulates of Limestone and
acidic fumes, most of which originates from impurities in the Limestone.
2. Minor reactions:
MgO+ + H2SO4 Mg SO4 + H2O
Fe2O3+3H2SO4 Fe2 (SO4) 3+ 3 H2O
Al2O3+3H2SO4 Al2(SO4) 3 + 3 H2O
3. Pollution reaction:
Cl2 + 2NaOH 2NaCl + H2O
CO2 + 2NaOH Na2CO3 + H2O
Both Chloride and CO2 are gases at ambient temperature and pressure and collected in the Den by
scrubbing system. The Chloride evolution is about 0.01% Chlorine in the Limestone.
Raw Material
Limestone 30% -50% CaO Limestone Powder
Acid 98% Concentrated acid, 70% Spent acid.
Water Recycled Water, Fresh Water
Mixer
The name itself suggests the function of the equipment. In the mixer the Limestone, 98% H2SO4
acid and water are mixed to form slurry. The optimum ratio is
Limestone 55.00 to 62% depending on Lime quality.
98% H2SO4 40.00 to 42.00%
Water 35 .00%
About 50 to 60% concentration is used for getting the better conversion. The retention time is
about 3-4 minute.
Den
The Den is horizontal tunnel through which the slurry of acid and Limestone proceeds on a slowly
moving slatted conveyor, which is also known as broadfield den. The resistance time is typically an
hour. During this time cake formation takes place. The gases are evolved in the process of
Gypsum production, which are scrubbed with the help of three stage scrubbing system.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 59 JM EnviroNet Pvt. Ltd.
Storage and Curing of Gypsum
The Gypsum material is transferred from Den to storage piles through EOT Crane, where further
curing takes place. It contains about 10% moisture and during this maturing stage the moisture
content reduces. It is reshuffled with crane for further processing or dispatched in bulk or packed
form. Curing of Gypsum takes 1 week.
Technical Specification of Equipments
S.No. Description Capacity / Size
1. Lime storage hopper filling capacity 100 mt
2. 2 Rotary air lock with VFD drive 65 mt
3.2 Screw conveyor with speed sensors
& VFD drive65 mt
4. Bucket elevator (belt/chain) 65 TPH, Make-Aumund/Enexco/Mecp
5. Buffer hopper capacity 5 mt
6. Weigh feeder 65 TPH,Make-transweigh/spil
7. Pre Mixer & Mixer65 TPH,Paddles-Casted Ni resist (12-14% Ni min.),bolt-brass/ss, inside 1
layer-rl (rubber lining) /frp lining,2-acid brick,3rd-carbon brick
8. Den (65 TPH) &Chain65 TPH, chain with T-slate make-tidc/indo,filling factor-0.75,Shaft IS 40
C8, girth gear &pinion- CS casted,inside double layer frp
9. Cyclone rl double layer (3+3) inside,shore hardness-85-90 and frp lining outside
10. Ventury rl double layer (3+3) inside,shore hardness-85-90 and frp lining outside
11. Ejector rl double layer (3+3) inside, shore hardness-85-90 and frp lining outside
12. Scrubber fan 72000m3/hr,450 mmwg,double layer rl / frp, impeller double layer rl
13. Dust collector unit with compressor 12000 m3/hr Make-Thermax / fluidair,50 m3/hr make-chicago pneumatic
14. 8 Pumps & pipe line
ejector- 100 m3/hr,ventury- 20 m3/hr, cyclone&rcc tower -20 m3/hr-
2set,acid feed pump & mixer -20 m3/hr-5 set, vertical gland less Make
Camlin, acid line hdpe / ms, scrubber water hdpe line
15. Chimney & velocity (m/sec)Height-50 mtr,flow 4500 m3/hr,rl 6 mm (3+3) inside all
surface&frplining,acid proof brick lining in bottom (1.5 mtr),
16.5 Acid tank capacity with level sensor
+ 1 blank acid tank
1000 mt,Size ID-11.5 x 6 mtr height, base plate:25mm, 0-1.5 mtr.: 16mm,
1.5-3.0mtr.: 12mm, remaining: 10mm and top plate: 6mm thk.
17. 2 EOT Crane with grab 10 mtRail mounted,doublegirder,lifting capacity -10 mt(incl. bucket) x 23 mtr
span, qty-2 Nos, bucket-5 cum,class-4 extra heavy duty as per IS-4137
18. All gear boxes (helical) Elecon/Naw
19. Crane shed 25 x 139 X 6 mtr
20. Chute & Ducting 65 TPH, double layer frp
21. Water tank Acid proof brick lining + all chamber below ejector, below ventury
22. Process shed 20 x 24 mtr
23. Service & unloading tank 30MT, 3*3*2 mtr
24. Couplings Geared coupling Make-NAW, pinBush-Lovejoy
25. Sprockets CS with hardened teeth
26. Total Power 12 unit/mt of gypsum
27. Moisture 10-12%(occasionally-15) with 6 ph value
Note: rl=rubber lining; 3+3= 3mm thick two layers of 80 - 90 shore hardness
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 60 JM EnviroNet Pvt. Ltd.
2.6.4 Equipment Details
2.6.4.1 Equipment Selection
A list of equipment and storages capacities are given below. In selecting a particular type of
equipment or storage for the project, among others, the following issues have been considered:
Equipment costs
Energy consumption
Raw material characteristics
Sizes in which the equipment is available
Lead times for particular types of equipment
Operating experience with various types of equipment
Ease of operation of equipment
Product to be manufactured
Site conditions
Local skills available
Environmental issues
2.6.4.2 Plant and Equipment Sizing
Details regarding Plant and equipment sizing for new 2.6 MTPA clinker Unit - XI and 4.4 MTPA
cement mill are given in Table - 2.9.
Table- 2.9
Plant and Equipment Sizing
S. No. Particulars Equipment Size (TPH)
1. Crusher
i) Primary 1450 TPH
ii) Secondary 450 TPH
2. Stacker and Reclaimer
i) Limestone Stacker 1650 TPH
ii) Limestone Reclaimer 1400 TPH
iii) Coal and Gypsum stacker 150 TPH each
iv) Coal Reclaimer 150 TPH
3. Raw Mill (VRM) 550 TPH
4. Cement Mill (VRM/ Ball Mill with Roller Press/ VRM + BM) 15000TPD
5. Coal and Pet coke mill 45 TPH with pet coke / 60 TPH with coal
6. Kiln& Cooler with 6 stage pre heater 8500 TPD
7. Packer 4 x 16 spouts
Source: Pre-feasibility Report
2.6.5 Storage Facilities
Details reg. storage facilities for raw material and product are given in Table - 2.10.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 61 JM EnviroNet Pvt. Ltd.
Table- 2.10
Storage Facilities
S. No. Type of MaterialsType of Storage Capacity (Tonnes)
Existing Proposed Existing Proposed
1. Limestone Stockpile Stockpile 540000 240000
2. Clinker Stockpile /Silo Stockpile /Silo 300000 75000
3.Indian and Imported Coal,
Pet Coke & LigniteCovered Dome Silo Covered Dome Silo 550000 200000
4. Cement Silo Silo 35000 4x7500
5.Gypsum (Mineral, Synthetic,
Chemical & Imported)Covered Yard Covered Yard 15000 20000
6. Fly ash Silo Silo 10500 2x5000
7.Laterite/ Lead Zinc Slag/ Iron
oreStockpile Stockpile 50000 3000
Source: Pre-feasibility Report
2.6.6 Infrastructure facilities
Labor is one of the key factors of production; hence, it will be ensured that apart from Colony for
regular employees, laborers will be provided with infrastructure facilities during construction as
well as operation phase.
During Construction phase, minimum space will be allocated per person or per family in terms of
floor area. Supply of safe water in the workers dwelling in such quantities as to provide for all
personal and household uses will be ensured. Adequate sewage and garbage disposal systems will
be ensured. Appropriate protection against heat, cold, damp, noise and fire. There will be
adequate sanitary and washing facilities, ventilation, cooking, storage facilities and natural and
artificial lighting.
Whereas, during operation phase for casual workers such as Truck drivers, workplace facility such
as; Canteens, Rest rooms, first aid facility as well as Injury/incident/hazards reporting procedures
will be provided. Casual workers will be kept under the purview of health and safety
representative during the period of engagement.
2.7 Township / Residential Colony
Location
The site of the Residential colony is near village Bagatpura,Tehsil Jaitaran, Pali (Raj.), around 2.2
km towards SSE from plant site.
Details of Colony
S. No. Description Total
1 Land area (ha) 40
2 Super Built-up area (sq meter) 136766
3 Covered Area, ha 5.1
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 62 JM EnviroNet Pvt. Ltd.
S. No. Description Total
4 Green Area, ha 14.5
5 Planation, numbers 35327
6 Cost, Rs in Crores 300
7 STP 275 (200 + 75 KLD)
8 STP cost, Rs in Lacs 80
9 Borewells, numbers 5
10 Drinking Water Requirement, KLD 25
11 Utility and Domestic Water Requirement, KLD 310
12 Total Water Requirement (2500 resident*135 Ltr/Person) 335
13 Sewage water generation, KLD (80% of water consumption) 270
14 STP treated water for Planation, KLD (95% of sewage generation) 255
15 Number of Rooms in Studio Apartment, guest house, hostel 112
16 Residential Quarters 599
17 Temple, club, auditorium, school, Gym, Shopping center and playground etc -
18 Total nos. of residents 2500
19 Type of Soil Clay loam
20 Dosage of settled sewage (m3/ha/day) 56 (minimum)
21 Sewage water intake capacity, M3/Day 812
22 Power Requirement, KVA 3200 kva
23 Source of Power Existing SCL CPP, WHRS & GRID
Construction Details of Township
S.
No.Type of buildings
No. of
Tower
No. of
floors per
tower
Units
per
floor
Total
no. Of
units
Total Super
Built Up
Area (sqm)
Cost /Sq
Meter,
Rs.
Total
Cost, Rs.
Crores
1. J type Bungalow - - - 2 743 28000 2.08
2. A Type - - - 9 2928 27000 7.9
3. B 1 & B2 2 7 4 56 14011 21000 29.42
4. B 3 1 7 4 28 7029 21000 14.76
5. C 3, C5, C7, C1 4 7 4 112 21409 19000 40.68
6. C 2, C4 & C6 3 7 4 84 16119 19000 30.64
7. D1, D3, D4, D6, D20, D24 6 7 4 168 25674 18000 46.21
8. D2, D5, D21, D23, D25 5 7 4 140 21269 18000 38.28
9. Studio apartment (48 rooms) - - - - 5030 27000 13.58
10. Guest House (24 rooms) - - - - 2879 27000 7.8
11. Hostel (32 rooms) - - - - 3062 27000 8.3
12.Amenities for Guest House &
Studio- - - - 5947 27000 16.05
13. School - - - - 6506 22000 14.31
14. Auditorium - - - - 1301 22000 2.86
15. Club - - - - 372 22000 0.82
16. Health management Center - - - - 372 27000 1.00
17. Security barrack - - - - 1632 18000 2.93
18. Main Gate office and barrier - - - - 112 15000 0.17
19. Gym - - - - 139 22000 0.31
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - II of Final EIA / EMP Report
M/s. Shree Cement Ltd. 63 JM EnviroNet Pvt. Ltd.
20. Shopping Centre (Complete) - - - - 232 15000 0.34
21. Landscaping 4.00
22. STP (75 + 200 KLD) 0.80
23. Land 0.2842
24. Miscellaneous 16.50
Total 21 - - 599 136766 300.00
Total super Built Up Area (Sqm) 136766
Total Ground Coverage Area (Sqm) 50945
Number of car parking 700
Total Green Area 145687
FAR (Total Floor Area + half the ground area/total land area) 0.4457
Amenities - Club House, Gym, Shopping Centre, School, health management
Centre,PlayGround, Auditorium, central park for kids
Colony Layout
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 64 JM EnviroNet Pvt. Ltd.
CHAPTER - III
DESCRIPTION OF THE ENVIRONMENT
3.1 INTRODUCTION
In order to assess the impacts of proposed expansion project on existing physical, biological and
social environment, it is necessary to study the present scenario of the area by collecting
information on the following parameters:
1. Land Environment
2. Meteorology
3. Air Environment
4. Noise Environment
5. Water Environment
6. Soil Environment
7. Biological Environment
8. Socio-economic Environment
The relevant information and data (both primary and secondary) were collected in core as well as
buffer zone (10 km distance from the plant boundary) during Summer Season (March to May,
2015) in accordance with the guidelines for preparation of EIA studies.
3.2 STUDY AREA AT A GLANCE
Study Area: An area of 10 km radius (aerial distance) from the plant site is marked as study area (as
shown in Figure 1.3; page no. 37). The baseline information is collected for the identified study area,
where plant site is considered as the core zone and area within 10 km radius of the plant site is
considered as buffer zone.
The study area is entirely rural and falls in Tehsil Jaitaran of Pali District of Rajasthan. It extends
from Latitude 26o 15 31.6 to 26o 16 45.3 N and through Longitude 74o 10 53 to 74o 11 48.1 E.
Location Map showing the Plant site has been given in Figure 1.2; page no. 36.
3.3 BASELINE DATA COLLECTION
Baseline data was collected composite for plant and mine during Summer Season (March to May,
2015) to assess the present scenario of the area.
3.3.1 Primary Data
Primary data was collected by monitoring and surveying of various environmental components /
parameters in the core as well as buffer zone (plant and mine) during the study period (March to
May, 2015); details of which are given in Table - 3.1.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 65 JM EnviroNet Pvt. Ltd.
Table - 3.1
Primary Data Collection
S. No. Description
1. Meteorology
Meteorological parameters on hourly basis at plant site.
Parameters: Temperature, Relative humidity, Wind Speed and Wind Direction.
2. Air
Ambient air quality monitoring (24 hourly), twice a week.
Parameters: PM10, PM2.5, SO2, NOx, CO.
No. of Locations: 12 locations in core and buffer zone of plant and mine site.
3. Noise
Noise level monitoring (day and night time), once in a season.
No. of Locations: 12 locations in core and buffer zone of plant and mine site.
4. Water
Ground water sampling, once in a season.
No. of Locations: 9 locations in core and buffer zone of plant and mine site.
Tested for physical and chemical parameters.
5. Soil
Soil sampling, once in a season.
No. of Locations: 9 locations in core and buffer zone of plant and mine site.
6. Biological Environment
Biodiversity survey, once in a season.
Location: Core and buffer zone.
7. Socio-economic Environment
Socio-economic survey, once in a season.
Location: Core and buffer zone.
3.3.2 Instruments Used for Environmental Baseline Data Collection
The following instruments were used at the site for environmental baseline data collection work.
1. Respirable Dust Sampler with attachment for gaseous Pollutants, Envirotech APM 460
2. Fine Particulate Matter (FPM) Sampler APM 550
3. Sound Level Meter Model Envirotech SLM - 100
4. Digital D.O. Meter Model - 831 E (CPCB Kit)
5. Weather Monitoring Station Model Enviro WM 271
6. Water Level Indicator and
7. Global Positioning System (GPS)
Apart from collecting samples of air, water, noise and soil from representative sampling points
given in proceeding sections, the data on land use, vegetation and agricultural crops were also
collected by the field team through interaction with a large number of local inhabitants of the
study area and different Government departments / agencies. This provided an excellent
opportunity to the members of the field team for obtaining clear scenario of the existing
environment of the study area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 66 JM EnviroNet Pvt. Ltd.
3.4 LAND USE / LAND COVER STUDY
3.4.1 Objective
To comply with the ToR points issued vide letter no. J - 11011/343/2012-IA II (I) dated 10th
February, 2016 by EAC (I), MoEFCC, New Delhi.
ToR Point no. 3 of additional ToRs for cement industry: Present land use should be prepared
based on satellite imagery. High-resolution satellite image data having 1m-5m spatial
resolution like quickbird, Ikonos, IRS P-6 pan sharpened etc. for the 10 Km radius area from
proposed site. The same shall be used for land used / land-cover mapping of the area.
To develop land use and land cover map using land coordinates of the plant area
To identify and mark important basic features according to primary and secondary data
To evaluate the project's impact on existing land use of the project area
To suggest measures for conservation and sustainable use of land
3.4.2 Data Used
Current vintage data of Indian Remote Sensing Satellite RESOURCESAT-2 (L4FMX) digital FCC
(False Color Composite) has been used for preparation of Land use/ Land cover thematic map of
study area.
Satellite image has been procured from National Remote Sensing Centre, Hyderabad. Survey of
India toposheet as a reference map on 1:50,000 scale has been used for preparation of base layer
data like road, rail network, village and plant site and for geo-referencing of satellite image.
Base map of the study area is given in Figure - 3.1.
Technical details of Data
Satellite Image - RESOURCESAT-2 (L4FMX)
Satellite Data Source - NRSC, Hyderabad
SOI Toposheets No. - 45 J/3, 45 J/4, 45 J/7 and 45 J/8
Software Used - Earth Resources Data Analysis System (ERDAS) Imagine 9.2
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 67 JM EnviroNet Pvt. Ltd.
3.4.2.1 Base Map of the Study Area
Source: SOI Toposheets
Figure 3.1: Base Map of the Study Area
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 68 JM EnviroNet Pvt. Ltd.
3.4.3 Methodology
Preliminary / primary data collection of the study area
o Satellite data procurement from NRSC Hyderabad
Secondary data collection from authorized bodies
o Survey of India Toposheet (SOI)
o Plant Layout
o Cadastral / Khasra map
o GPS Coordinates of Plant Boundary
Processing of satellite data using ERDAS Imagine 9.2 and to prepare the Land use and Land
cover maps (e.g. Forest, agriculture, settlements, wasteland, water bodies etc.) by digital
image processing (DIP) technique.
o Geo-Referencing of the Survey of India Toposheet
o Geo-Referencing of satellite Imagery with the help of Geo-Referenced Toposheets
o Enhancement of the Satellite Imagery
o Base Map layer creation (Roads, Railway, Village Names and others Secondary data
etc.)
o Data analysis and Classification using Digital interpretation techniques
o Ground truth studies or field Verification
o Error fixing / Reclassification
o Final Map Generation
3.4.4 Details of LULC
3.4.4.1 Land Use and Land Cover Classes
These are the following LULC Classes:
Water Bodies, Crop land, Fallow Land, Human Settlement, Industrial Area, Mine Quarry, Scrub
Land, Plantation, Railway Line, Road Network, Forest Land, Stony Waste Land, Open Land etc. as
per NRSC Guide Line.
Definitions of LULC Classes
(Reference- National Remote Sensing Centre Guideline)
Agriculture Land: These are the lands primarily used for farming and for production of food, fiber,
and other commercial and horticultural crops. It includes land under crops (Irrigated and non-
irrigated, Fallow, Plantation etc.)
Crop Land: These are the areas with standing crop as on date of satellite overpass. Cropped areas
appear in bright red to red in color with varying shape and size in a contiguous to non-contiguous
pattern. Three cropping seasons exist in India viz., Kharif (June/July-September/October), Rabi
(November-December-February-march) and Zaid (April-May).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 69 JM EnviroNet Pvt. Ltd.
Fallow Land: These are the lands, which are taken up for cultivation but are temporarily allowed to
rest, un-cropped for one or more seasons. Fallow land is categorized in two classes which Current
Fallow and Long Fallow.
Current Fallow Land: These are the cropland areas, which are un-cropped during the agriculture
year under consideration as on the date of satellite overpass.
Long Fallow Land: These are the croplands areas, which are un-cropped for Two to Four
Agriculture Years from the base year.
3.4.4.2 Generation and Analysis of Data
Geo-referencing of the Survey of India Toposheet
Scanned surveys of India Toposheets were registered in geographic lat/long projection system
with the help of ERDAS imagine software and re-project in UTM WGS 84 with respective zone.
Geo-Referencing of the Satellite Imagery
Registered Toposheets is used as a reference map for Geo-Referencing of Raw satellite imagery
by taking suitable Ground Control Points (GCP) like intersection point of railway, Road network,
Canal intersection and some other permanent features.
Figure 3.2: Geo-Referencing of Satellite Image using SOI Toposheet
Enhancement of Satellite Image
Satellite data is composed of substantial noise and haze errors due to various environmental
factors, which affect the amount of reflectance (information) that can be deciphered. Since
mapping of satellite images is based on spectral signatures, it is necessary to normalize the
redundant values into near true values. This process of deriving true reflectance values is known
as normalization. This enhances interpretability of the satellite image thereby facilitating better
identification of land features viewed on satellite imagery. Histogram equalization and radiometric
correction has been used for satellite image enhancement.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 70 JM EnviroNet Pvt. Ltd.
Original Image Radiometrically Enhanced Image
Figure 3.3: Difference between Original Image and Radiometrically Enhanced Images
Base Map Layer Creation
Base map has been prepared using Survey of India Toposheet as a reference map on 1:50000
scale. In base layer linear and point feature like road, rail, canal, village location and other
secondary information have been created in vector data format with the help of ArcGIS Software.
Data Analysis and Classification Using Digital Interpretation Technique
Image interpretation is the process of identifying objects or conditions in images and determining
their meaning or significance. Satellite imagery are composed of array of grid; each grid has a
numeric value that is known as digital number. Smallest unit of this grid is known as a pixel that
captures reflectance of ground features represented in terms of Digital number, which represent
a specific land features.
Using image classification technique, the satellite data is converted into thematic information map
based on the user s knowledge about the ground area.
Hybrid technique has been used i.e. visual interpretation and digital image processing for
identification of different land use and vegetation cover classes based on spectral signature of
geographic feature. Spectral signature represents various land use classes. Image interpretation
keys are developed for better Interpretation/Classification scheme which is Shape, Size, Color,
Tone, Texture Pattern, Association etc. Based on the Interpretation key and Spectral Signature
Entire satellite imagery is classified in different classes like Water Bodies, Crop land, Fallow Land,
Human Settlement, Industrial Area, Mine Quarry, Scrub Land, Plantation, Railway Line, Road
Network, Forest Land, Stony Waste Land, Open Land etc.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 71 JM EnviroNet Pvt. Ltd.
Ground Data Collection and Verification
Ground truth/ field verification is an important component in mapping and its validation exercise.
Utmost care and planning is required for collecting ground data and verification. To facilitate a
good ground truthing exercise the following steps were followed:
o Identifying and listing all the doubtful areas for the ground verification and referring all such
areas with respect to the toposheet to know their geographical location and accessibility on
the ground.
o Field traverse plan was prepared to cover maximum doubtful areas in the field in such a way
that each traverse covers, as many land use and land cover classes as possible, apart from
the doubtful areas
o The sufficient number of points were covered for each Land Use Class as required for
quality checking as well as accuracy assessment.
Error Fixing / Reclassification
Reclassification of Land Use classes was done on the basis of data collected / verified during
ground truthing.
Final Map Generation
Final maps are generated for the core area as well as Buffer area. 3 Pixels is Filtered using Clump
and Eliminate Process after ensuring to maintain crucial classes of importance. Base map layers
are overlaid on the classified raster data and then thematic maps are generated on the layout
consisting of Project name, legend, source of data, Index map, scale bar and North arrow.
3.4.4.2.1 Land Use / Land Cover Details of Core Zone
A hybrid technique has been used i.e. visual interpretation and digital image processing to
generate output Land use and Land cover map of the core zone as well as 10 km buffer area on
1:50000 scale.
The land use and land cover details of the core zone are given in Table - 3.2.
Table - 3.2
Land Use / Land Cover Details of Core Zone
S. No. Legend Area (in ha) Area (in %)
1. Water Bodies 1.63 0.70
2. Open Land 117.62 50.80
3. Plantation 46.76 20.20
4. Industrial Area 65.53 28.30
Total 231.54 100.00
Source: LU / LC Map for Core Zone
In the core zone, 20.20% of the area falls under greenbelt / plantation while 50.80% is open land.
28.30% falls under industrial area. Barely, 0.70% of the area is under water bodies (Rainwater
Harvesting Pond).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 72 JM EnviroNet Pvt. Ltd.
Land Use / Land Cover Map of Core Zone
Source: Satellite Imagery
Figure 3.4: Land Use / Land Cover Map of the Core Zone
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 73 JM EnviroNet Pvt. Ltd.
3.4.4.2.2 Land Use / Land Cover Details of Buffer Zone
The land use and land cover details of the buffer zone are given in Table - 3.3.
Table - 3.3
Land Use / Land Cover Details of Study Area
S. No. Legend Area (in ha) Area (in %)
1. Water Bodies 9.60 0.03
2. Seasonal Water Bodies 453.12 1.18
3. Open Land 106.02 0.28
4. Open Scrub land 4499.86 11.75
5. Stony Area 13392.27 34.98
6. Mine Quarry 377.90 0.99
7. Forest Land 241.90 0.63
8. Plantation 709.68 1.85
9. Fallow Land 15111.46 39.47
10. Crop Land 2455.46 6.41
11. Human Settlement 711.07 1.86
12. Industrial Area 217.63 0.57
Total 38285.97 100.00
Source: LU/LC Map for Buffer Zone
The study area mainly comprises of fallow land (39.47%). Thus, other classes occupy only 60.53%
of the area. The second largest area (13392.27 ha) is covered by the class stony area which is
34.98% of total study area. The area which has been excavated or where the soil cover is very thin
falls under open scrub land which constitutes 11.75% of the area. The SSE portion is dominated by
forest land which makes up to 0.63%. Around 6.41% of the total area falls under Crop Land.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 74 JM EnviroNet Pvt. Ltd.
Land Use / Land Cover Map of Buffer Zone
Source: Satellite Imagery
Figure 3.5: Land Use / Land Cover Map of the Buffer Zone
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 75 JM EnviroNet Pvt. Ltd.
3.4.5 Observation of the LULC Data
In the core zone, 20.20% of the area falls under green belt / plantation while 50.80% is open
land. 28.30% falls under industrial area. Barely, 0.70% of the area is under water bodies
(Rainwater Harvesting Pond).
The study area mainly comprises of fallow land which constitutes 39.47% of the total area
Thus, other classes occupy only 60.53% of the total area. The second largest area falls under
stony area which constitutes 34.98% of total study area.
There are 2 rivers i.e. Lilri River (Seasonal) which falls at the distance of approx. 1.5 Km in
North direction and Sukri River at approx. 8.0 Km in SSW direction from plant site. There is
only one Reserve Forest (~5.0 Km in SSE direction) and one Protected Forest (~9.9 Km in SE
direction) within 10 Km radius of study area.
Mine Site is located adjacent to the plant site.
Village Nimbeti, Bhimgarh, Kanyakheri, Ras, Patan, Kundal etc. are the nearest villages from
the plant site.
There are no National Park, Wild Life Sanctuary, Biosphere Reserve etc. within 10 km radius of
the study area.
3.4.6 Identification of Impacts on Land Use Pattern Due to Project Activity
Impact on Core Zone
Total plant area is 231.54 ha including existing plant (187.56) and additional area (43.98 ha)
within plant boundary and proposed expansion will be done within the existing plant
premises.
Infrastructure facilities are already present in the existing cement plant; additional may be
developed on the basis of requirement
Impact on Buffer Zone
There will be increase in the vehicular movement due to the proposed expansion activity
Main impact on the agriculture land will be on surrounding Villages such as Nimbeti,
Bhimgarh, Kanyakheri, Ras, Patan, Kundal etc
Presently 1.86% area is covered by human settlement but due to continuous population
growth, agriculture land will be converted into residential area. The rate of land use change
will depend on the population growth and socio-economic status of the study area
3.4.7 Recommendations
Adequate and Efficient air pollution control equipments have been installed to maintain the
pollution level within limits.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 76 JM EnviroNet Pvt. Ltd.
Thick Greenbelt / Plantation has already been developed and will be enhanced and
additional green belt / plantation will be developed in the plant area and along the roads, so
that dust emission impacts can be minimized on surrounding agriculture field.
The following practices will be carried out to increase the productivity of the study area:
o Awareness for new methodologies of the agricultural practices viz. mixed farming, crop
rotation and agricultural cropping pattern suitable for the area
o Providing seeds, manure and fertilizers from different sources
o Rainwater harvesting practices will be encouraged which will lead to ground water
recharge and ultimately increased productivity in the study area
3.4.8 Conclusion
Remote Sensing data provides real time information pertaining to aspects of Land use / Land
cover. Precise quantitative information could be extracted about existing land use / land cover in
context to spatial dimension. Integration of various data layers gives proper understanding of the
problems.
3.4.9 Digital Elevation Model
Digital Elevation Models are data files that contain the elevation of the terrain over a specified
area, usually at a fixed grid interval over the "Bare Earth". The intervals between each of the grid
points will always be referenced to some geographical coordinate system. This is usually either
latitude-longitude or UTM (Universal Transverse Mercator) coordinate systems. The closer
together the grid points are located, the more detailed the information will be in the file. The
details of the peaks and valleys in the terrain will be better modeled with small grid spacing than
when the grid intervals are very large. Elevations other than at the specific grid point locations are
not contained in the file. As a result, peak points and valley points not coincident with the grid will
not be recorded in the file. For practical purpose, this "Bare Earth" DEM is generally synonymous
with a Digital Terrain Model (DTM).
DEM has been prepared for Cement plant of Shree Cement Ltd. for 10 km radius study area.
3.4.9.1 Data Used
DEM Data : Shuttle Radar Topographic Mission (SRTM) data
Data Source : http://srtm.csi.cgiar.org
Software Used : Arc GIS
3.4.9.2 Methodology
Shuttle Radar Topographic Mission (SRTM) data has been used for creation of Digital Elevation
Model of the study area. The SRTM data has vertical accuracy of 16m and the spatial resolution is
of 90 m.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 77 JM EnviroNet Pvt. Ltd.
1st Stage:
The first processing stage involves importing and merging the 1-degree tiles into continuous
elevational surfaces in Arc GRID format.
2nd Stage:
Re-sampling the data at 23 m is done and a contour interval of 10m through the usual process of
interpolation is created.
3rd Stage:
SRTM data is converted in grid format through Arc GIS 9.2 to obtain elevation information of
study area. Contours are then generated at 10 m interval through 3D analyst of Arc GIS and then
are interpolating with raster data.
4th Stage:
Integration of DEM with contour map showing 3D view for analysis of surface is done.
Digital Elevation Model (DEM) of the Study Area with Contour Map and 3-D View DEM is given in
Figure - 3.6 and 3.7, respectively.
3.4.9.3 Interpretation
It is very clear from the DEM that the elevation varies from 317 m to 533 m in the whole study area,
having the contour interval of about 20 m. The areas in the SW portion have generally higher
elevation which constitutes Open Scrub land while the low lying areas are generally used for
agricultural purposes and habitation. The contour over the DEM shows that the plant site is in the
elevation range of 374 m to 400 m present on the flat land.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 78 JM EnviroNet Pvt. Ltd.
Figure 3.6: Digital Elevation Model of the Study Area with Contour Map
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 79 JM EnviroNet Pvt. Ltd.
Figure 3.7: 3-D View
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter -III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 80 JM EnviroNet Pvt. Ltd.
3.5 SEISMICITY AND FLOOD HAZARD ZONATION OF THE AREA
3.5.1 Seismicity of the Area
Many parts of the Indian subcontinent have historically high seismicity. Seven catastrophic
earthquakes of magnitude greater than 8 (Richter scale) have occurred in the western, northern
and eastern parts of India and adjacent countries in the past 100 years.
Approx. 59 % of the land area of India is liable to seismic hazard damage. In India, seismic zones
are divided into four zones i.e. V, IV, III and II. Details of the seismic zone are given in Table - 3.4.
Table - 3.4
Seismic Zones in India
S. No. Seismic Zone Risk Intensity on MMI scale
1. Zone - V Very High Risk Zone IX & above
2. Zone - IV High Risk Zone VIII
3. Zone - III Moderate Risk Zone VII
4. Zone - II Low Risk Zone VI & below
Source: IMD & NIDM
Rajasthan has not had a major earthquake in recent years, though small to moderate earthquake
have been felt in the state. Several faults have been identified in this region out of which many
show evidence of movement during the Holocene epoch. The Cambay Graben terminates in the
south-western part of the state. The Konoi Fault near Jaisalmer trends in a north-south direction
and was associated with the 1991 Jaisalmer earthquake. Several active faults criss-cross the
Aravalli range and lie parallel to each other. The most prominent of them is the north-south
trending Sardar Shahar Fault and the Great Boundary Fault which runs along the Chambal River
and then continues in the same direction into Uttar Pradesh. However, it must be stated that
proximity to faults does not necessarily translate into a higher hazard as compared to areas
located further away, as damage from earthquakes depends on numerous factors such as
subsurface geology as well as adherence to the building codes.
The plant site as well as study area lies in Zone - II of Seismic Zoning Map of India, updated by India
Metrological Department (IMD) and National Institute of Disaster Management (NIDM), and thus
can be said to be located in an area of Low Risk Zone by national standards. Seismic Zoning Map
of India showing the plant site (Pali) is given in Figure - 3.8.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter -III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 81 JM EnviroNet Pvt. Ltd.
Figure 3.8: Seismic Zone Map
Plant Site
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter -III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 82 JM EnviroNet Pvt. Ltd.
3.5.2 Flood Hazard Zonation of the Area
As per the Vulnerability Atlas - 2nd Addition; Peer Group, MoH and UPA; based on digitized data of
SOI, GOI; Flood Atlas, Task Force Report, C.W.C., GOI the plant site does not fall under area
liable to flood . Flood Hazard Zonation Map showing the plant site is given in Figure - 3.9.
Figure 3.9: Flood Hazard Zonation Map of the Area
Plant Site
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter -III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 83 JM EnviroNet Pvt. Ltd.
3.6 CLIMATE AND RAINFALL
Climate of Pali is classified as tropical with maximum temperature of 41.9 C in May and minimum
temperature of 12.7 C in Dec. Temperatures begin to rise in February. May is the hottest month
with a mean maximum temperature of 41.9°C and minimum of 28°C.
Monsoon marks the rainy season, lasting form June to September, bringing most of the rainfall to
the region. The average annual rainfall is about 468 mm. The humidity is relatively more during the
rainy season.
Rainfall record data of nearest rain gauge at tehsil headquarter Jaitaran is shown below in Table -
3.5.
Table - 3.5
Rainfall Data for last 10 Years
S. No. Year Rainfall (mm)
1. 2005 304
2. 2006 368
3. 2007 585
4. 2008 431
5. 2009 229
6. 2010 571
7. 2011 640
8. 2012 412
9. 2013 583
10. 2014 557
Source: Tehsil Headquarter, Jaitaran
Figure 3.10: Rainfall for last 10 years
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter -III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 84 JM EnviroNet Pvt. Ltd.
3.7 METEOROLOGY
Meteorology plays a vital role in determining the transport and diffusion pattern of air pollutants
released into atmosphere. The principal variables include horizontal convective transport (average
wind speed and direction), vertical convective transport (atmospheric stability) and topography of
the area.
Meteorological characteristics of an area are very much important in assessing possible
environmental impacts and in preparing environmental management plan.
Since meteorological factors show wide fluctuations with time, meaningful interpretation can be
drawn only from long-term reliable data. Such source of data is India Meteorological Department
(IMD), which maintains a network of meteorological stations at several important locations.
The nearest IMD station to the plant site is located in Ajmer. The Meteorological data i.e.
temperature, relative humidity, rainfall, wind speed, and wind direction, recorded at two synoptic
hours i.e. 08:30 and 17:30 for Summer Season (March to May, 2015) was obtained from this station
to study meteorology of the study area.
3.7.1 Micro-Meteorology at Site
Meteorological station was set-up at site to record surface meteorological parameter during
Summer Season (March to May, 2015).
Wind speed and wind direction data recorded during the study period has enabled identifying the
influence of meteorology on the air quality of the area. Based on the collected meteorological
data, relative percentage frequencies of different wind directions were calculated and plotted as
wind roses for twenty four hour duration. Maximum and minimum temperatures including
percentage relative humidity were also recorded simultaneously.
It was observed that the predominant overall wind pattern for the study period was from SW
direction. Wind speed during this period varied from 0.1 m /sec. to 6.2 m / sec. Wind Rose Diagram
showing the wind pattern during the study period is shown in Figure - 3.11. There was not much
rainfall during the study period at site; total rainfall during the study period at Pali is 34 mm only
(Source: wunderground.com).
Summary of the micro-meteorology at site is given in Table - 3.6. Detailed Hourly Meteorological
Data has been enclosed as Annexure - 4 with this EIA / EMP Report.
Table - 3.6
Micro-Meteorology at Site
Study Period: Summer Season (March to May, 2015)
MonthTemperature (oC) Relative Humidity (%) Wind Speed (m / sec)
Max. Min. Max. Min. Max. Min.
March, 2015 39.5 12.2 92.7 8.0 6.2 0.1
April, 2015 44.2 20.3 81.6 5.1 4.2 0.2
May, 2015 43.5 8.2 46.9 5.2 4.2 0.1
Source: Meteorological Station at Site
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter -III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 85 JM EnviroNet Pvt. Ltd.
Figure 3.11: Wind Rose Diagram of Site
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter -III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 86 JM EnviroNet Pvt. Ltd.
3.8 AMBIENT AIR ENVIRONMENT
Ambient air quality monitoring is done to determine the general background concentration levels.
Samples were collected in the 10 km study area to observe pollution trends throughout the
region. It helps in providing a data base for evaluation of effects of a project activity in that region.
It will be also useful in ascertaining the quality of air environment in conformity to standards of
the ambient air quality during operation phase of project.
Methodology
The air quality monitoring and survey (Plant and Mine) was done during Summer Season i.e.
March to May, 2015, within 10 km radius study area as per the Terms of Reference (ToR) issued by
MoEFCC, New Delhi vide their letter no. J - 11011/343/2012-IA II (I) dated 10th Feb., 2016.
The samples were collected for the following air quality determinants:
Sulphur Dioxide (SO2)
Oxides of Nitrogen (NOx)
Particulate Matter (PM10 and PM2.5)
Carbon Monoxide (CO)
The sources of air pollution in the region are dust rising from unpaved roads, domestic fuel
burning, vehicular traffic, agricultural activities, emission from other industries, etc.
Sampling Schedule
The sampling was done continuously for 24 hours for SO2, NOx, PM10 and PM2.5 with a frequency of
twice a week for three months (24 observations for one location). The details of measurement
methodology and test procedure are given in Chapter - VI (Environmental Monitoring Programme)
of this report.
Sampling Locations
Sampling locations were selected for AAQ Monitoring keeping in view the pre-dominant wind
direction prevailing in the area during the study period.
It can be observed from the wind rose diagram (Figure - 3.11) that the predominant wind direction
during the study period was from SW. Villages / locations have been selected in the downwind
direction as well as in the upwind direction for AAQ monitoring from the plant and mine site.
Monitoring stations selected for Ambient Air Quality Monitoring during the study period are given
in Table - 3.7 and shown in Figure - 3.12.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 87 JM EnviroNet Pvt. Ltd.
Table - 3.7
Locations of Ambient Air Quality Monitoring Stations
S. No. Sampling Location
Plant Site Mine Site Selection Criterion
Approx. Aerial
DistanceDirection
Approx. Aerial
DistanceDirection Plant Site Mine Site
S1 Plant Site - - Adjacent E Core Zone -
S2 Nimbeti Mine Site Adjacent W - - - Core Zone
S3 Village Kundal 3.o Km SW 1.5 Km SWFalls in Upwind of dominant wind
direction
Falls in Upwind of dominant wind
Direction
S4Sampling station at
500 m0.5 Km North 0.5 Km NE Near to mine site
Falls in downwind of dominant
wind direction
Near to mine site
S5 Village Kanyakheri 2.5 Km NE 3.0 Km ENE
Falls in downwind of dominant
Wind direction.
In proximity to SH - 39
In proximity to SH - 39
S6 Village Ganeshpura 6.5 Km NNE 6.0 Km NE -Falls in downwind of dominant wind
direction
S7 Village Patan 3.0 km West 1.5 Km WestFalls in upwind of second dominant
wind direction
Falls in upwind of second dominant
wind direction
S8 Village Devgarh 5.0 Km East 6.0 Km EastFalls in downwind of second
dominant wind direction
Falls in downwind of second
dominant wind direction
S9 Village Ras 3.0 Km North 2.8 km NNE Nearest Village to Plant site -
S10 Village Nimbeti 0.5 Km NNW 1.5 Km North - Nearest Village to Mine Site
S11 Near Reserve Forest 3.0 Km SSE 4.5 Km SSENear to Reserved Forest (sensitive
receptor)
Near to Reserved Forest (sensitive
receptor)
S12 Village Bhimgarh 1.0 Km SE 1.2 Km EastFalls in downwind of third
dominant wind direction
Falls in downwind of second
dominant wind direction
Source: SOI Toposheets
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 88 JM EnviroNet Pvt. Ltd.
Source: SOI Toposheet
Figure 3.12: Key Plan showing Ambient Air Quality and Noise Monitoring Location
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 89 JM EnviroNet Pvt. Ltd.
Ambient Air Quality Monitoring
Table - 3.8 shows the maximum & minimum concentration of the air pollutants monitored at different
locations (as mentioned in Table - 3.7) during the study period. All 24 observations of pollutants for
each location are detailed in Ambient Air Quality Monitoring Tables enclosed as Annexure - 5 along
with this report.
Table - 3.8
Ambient Air Quality Monitoring Results
Study Period: Summer Season (March to May, 2015)
(Unit in g/m3)
S.
No.Sampling Location
PM10 PM2.5 SO2 NOx
CO
(mg/m3)
Max. Min. Max. Min. Max. Min. Max. Min. Max. Min.
S1 Plant Site 76.2 68.1 36.8 28.1 9.8 7.5 26.3 18.9 0.66 0.53
S2 Nimbeti Mine Site 81.0 70.1 38.1 28.7 9.6 7.2 25.4 18.4 0.62 0.52
S3 Village Kundal 66.2 57.1 30.2 21.4 7.9 5.6 22.1 14.2 BDL
S4 Sampling station at 500 m 75.1 66.1 36.2 26.1 9.3 6.4 24.8 18.0 BDL
S5 Village Kanyakheri 74.2 65.8 35.8 25.8 9.5 6.6 25.2 18.6 BDL
S6 Village Ganeshpura 68.2 58.1 32.2 23.5 8.5 5.6 24.5 17.2 BDL
S7 Village Patan 67.1 57.0 30.3 22.9 8.2 5.5 23.1 16.8 BDL
S8 Village Devgarh 68.4 57.6 32.1 23.6 8.5 5.8 24.8 15.5 BDL
S9 Village Ras 73.1 63.1 34.2 25.1 9.0 5.8 25.1 16.2 BDL
S10 Village Nimbeti 68.1 58.2 32.1 24.2 8.8 5.6 24.9 15.8 BDL
S11 Near Reserve Forest 64.1 56.2 28.1 20.6 7.1 5.2 21.0 14.8 BDL
S12 Village Bhimgarh 74.1 64.2 35.1 28.1 9.0 5.9 25.1 17.8 BDL
NAAQS* 100 60 80 80 04
Source: Ambient Air Quality Monitoring
*NAAQS - National Ambient Air Quality Standards; Schedule-VII, [Rule 3 (3B)], [Part-II-sec.-3(i)] 16.11.2009
BDL - Below Detectable Limit, Detection Limit of CO = 0.5 mg/m3
Graphs showing Concentrations (Max. and Min.) of PM10, PM2.5, SO2 and NOx at different monitoring stations are
given in Figure - 3.13 (A to D), respectively.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 90 JM EnviroNet Pvt. Ltd.
Figure 3.13 (A): Graph showing PM10 concentrations (Max. and Min.) at different monitoring stations
Figure 3.13 (B): Graph showing PM2.5 concentrations (Max. and Min.) at different monitoring stations
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 91 JM EnviroNet Pvt. Ltd.
Figure 3.13 (C): Graph showing SO2 concentrations (Max. and Min.) at different monitoring stations
Figure 3.13 (D): Graph showing NOx concentrations (Max. and Min.) at different monitoring stations
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 92 JM EnviroNet Pvt. Ltd.
National Ambient Air Quality Standards
Table - 3.9 shows the NAAQS prescribed by CPCB on 16th Nov., 2009.
Table - 3.9
NAAQS prescribed by CPCB
S. No. PollutantTime Weighted
Average
Concentration in Ambient Air
Method of MeasurementIndustrial Area,
Residential Rural &
Other Areas
Ecologically Sensitive
Area (Notified by
Central Govt.)
(1) (2) (3) (4) (5) (6)
1Sulphur Dioxide
(SO2), µg/m3
Annual Average
*
24 hours **
50
80
20
80
1. Improved West and Gaeke Method.
2. Ultraviolet fluorescence.
2Oxides of Nitrogen
as NO2, µg/m3
Annual Average
*
24 hours **
40
80
30
80
1. Modified Jacob & Hochheiser (Na-
Arsenite) Method.
2. Chemiluminescence (Gas phase).
3
Particulate Matter
(size less than 10µm)
or PM10, µg/m3
Annual Average
*
24 Hours **
60
100
60
100
1. Gravimetric,
2. TOEM,
3. Beta attenuation.
4
Particulate Matter
(size less than 2.5µm)
or PM2.5, µg/m3
Annual
Average*
24 Hours **
40
60
40
60
1. Gravimetric,
2. TOEM,
3. Beta attenuation.
5 Ozone (O3), µg/m3 8 Hours **
1 Hours *
100
180
100
180
1. UV Photometric,
2. Chemilminescence,
3. Chemical Method.
6 Lead (Pb), µg/m3
Annual Average
*
24 Hours **
0.50
1.0
0.50
1.0
1. AAS/ICP Method after sampling on EPM
2000 or equivalent filter paper.
2. ED-XRF using Teflon filter.
7Carbon Monoxide
(CO), mg/m3
8 Hours**
1 Hours
02
04
02
04
Non Depressive Infrared (NDIR)
Spectroscopy.
8Ammonia (NH3),
µg/m3
Annual
Average*
24 hours **
100
400
100
400
1. Chemiluminescence (Gas phase).
2. Indophenol blue method.
9Benzene (C6H6),
µg/m3
Annual
Average*05 05
1. Gas Chromatography based continuous
analyzer,
2. Adsorption and Desorption followed by
GC analysis.
10
Benzo ( ) Pyrene
(BaP)- Particulate
Phase only, ng/m3
Annual
Average*01 01
Solvent extraction followed by HPLC GC
analysis.
11 Arsenic (As), ng/m3 Annual
Average*06 06
AAS/ICP Method after sampling on EPM
2000 or equivalent filter paper.
12 Nickel (Ni), ng/m3 Annual
Average*20 20
AAS/ICP Method after sampling on EPM
2000 or equivalent filter paper.
*Annual arithmetic mean of minimum 104 measurements in a year at a particular site taken twice a week 24 hourly at uniform
intervals.
**24 hourly or 08 hourly or 01 hourly monitored values, as applicable, shall be complied with 98% of the time in a year. 2% of the
time, they may exceed the limits but not on two consecutive days of monitoring.
Note: Whenever and wherever monitoring results on two consecutive days of monitoring exceed the limits specified above for the
respective category, it shall be considered adequate reason to institute regular or continuous monitoring and investigation.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 93 JM EnviroNet Pvt. Ltd.
Conclusion
Ambient Air Quality Monitoring reveals that the concentrations of PM10 and PM2.5 for all the 12
AAQM stations were found between 56.2 to 81.0 g/m3 and 20.6 to 38.1 g/m3, respectively.
As far as the gaseous pollutants SO2 and NOx are concerned, the prescribed CPCB limit of 80 g/m3
has never surpassed at any station. The concentrations of SO2 and NO2 were found to be in range
of 5.2 to 9.8 g/m3 and 14.2 to 26.3 g/m3 respectively. CO concentration was also found within
limits.
3.8.1 Mineralogical Composition for RSPM
RSPM is defined as the component of inhaled respirable dust small enough to reach the
pulmonary or alveolar region of the lung .
Classification of RSPM
Classification Type of particles Size of the particles
PM10 Inhalable particles 10µm
PM2.5 Fine particles 2.5µm
The mineralogical composition of RSPM have Calcite, Dolomite, Vaterite, Aragonite Minerals
(Calcite Minerals) or Actinolite or Tremolite (Magnesium minerals) and Free Silica.
Chemical Characterization of RSPM is given in Table - 3.10.
Table - 3.10
Chemical Characterization of RSPM
S. NO. IONS QUANTITY (%)
1. Silica (SiO2) 1.19
2. Calcium (Ca) 12.3
3. Magnesium (Mg) 6.9
4. Iron (Fe) 2.3
5. Aluminium (Al) 2.6
6. Sodium (Na) 4.5
7. Potassium (K) 3.1
8. Manganese (Mn) 3.7
9. Chromium (Cr) 0.4
10. Nickel (Ni) 0.01
11. Zinc (Zn) 1.6
12. Copper (Cu) 0.8
13. Cobalt (Co) 0.50
14. Lead (Pb) 0.19
15. Mercury (Hg) BDL (DL - 0.00001)*
16. Cadmium (Cd) BDL (DL - 0.00005)*
17. Arsenic (As) BDL (DL - 0.00005) *
BDL Below Detectable Limit, *DL Detection Limit
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 94 JM EnviroNet Pvt. Ltd.
3.9 NOISE ENVIRONMENT
Noise often defined as unwanted sound, interferes with speech communication, causes
annoyance, distracts from work, and disturbs sleep, thus deteriorating quality of human
environment.
Source of Noise
There are several sources of noise in the 10 km radius of study area, which contribute to the local
noise level of the area. Ambient noise sources in the vicinity of the plant and mine site include the
noise from traffic on road, human activities in villages and agricultural fields.
Ambient Noise Level
In order to know the baseline noise levels, in and around the plant and mine site, noise levels were
measured at site and villages in the study area.
Sampling Schedule
The sampling was done during day time and night time once in the study period.
Sampling Locations
Locations / stations selected for noise level monitoring are given in Table - 3.11 and shown in Figure
- 3.12.
Table - 3.11
Locations of Noise Monitoring Stations
S. No. Sampling Location
Plant Site Mine Site
Approx. Aerial
DistanceDirection
Approx. Aerial
DistanceDirection
S1 Plant Site - - Adjacent E
S2 Nimbeti Mine Site Adjacent W - -
S3 Village Kundal 3.o Km SW 1.5 Km SW
S4 Sampling station at 500 m 0.5 Km North 0.5 Km NE
S5 Village Kanyakheri 2.5 Km NE 3.0 Km ENE
S6 Village Ganeshpura 6.5 Km NNE 6.0 Km NE
S7 Village Patan 3.0 km West 1.5 Km West
S8 Village Devgarh 5.0 Km East 6.0 Km East
S9 Village Ras 3.0 Km North 2.8 km NNE
S10 Village Nimbeti 0.5 Km NNW 1.5 Km North
S11 Near Reserve Forest 3.0 Km SSE 4.5 Km SSE
S12 Village Bhimgarh 1.0 Km SE 1.2 Km East
Source: SOI Toposheet
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 95 JM EnviroNet Pvt. Ltd.
Ambient Noise Level Monitoring
Ambient noise levels monitoring results monitored at different locations (as mentioned in Table -
3.11) during the study period are given in Table - 3.12.
Graphs showing Noise Levels during day time and night time at different monitoring stations are
given in Figure - 3.14 (A and B), respectively.
Table - 3.12
Ambient Noise Level Monitoring Results
Study Period: Summer Season (March to May, 2015)
S.
No.Sampling Locations
NOISE LEVEL dB Leq (A)
Day Time (6:00 am to 10:00 pm) Night Time (10:00 pm to 6:00 am)
S1 Plant Site 61.2 56.3
S2 Nimbeti Mine Site 63.2 57.1
S3 Village Kundal 53.1 43.4
S4 Sampling station at 500 m 54.8 44.9
S5 Village Kanyakheri 54.3 44.2
S6 Village Ganeshpura 52.6 41.3
S7 Village Patan 52.0 42.1
S8 Village Devgarh 50.4 42.1
S9 Village Ras 54.8 44.6
S10 Village Nimbeti 54.6 44.2
S11 Near Reserve Forest 50.2 39.4
S12 Village Bhimgarh 54.5 44.7
Source: Ambient Noise Quality Monitoring
CPCB Noise Standards are given in Table - 3.13.
Table - 3.13
CPCB Noise Standards*
Area Code Category of Area
Limits in Leq. dB (A)
Day Time
(06.00 am 10.00 pm)
Night Time
(10.00 pm 6.00 am)
(A) Industrial Area 75 70
(B) Commercial Area 65 55
(C) Residential Area 55 45
(D) Silence Zone 50 40
1. Day Time is from 6.00 AM to 10.00 PM.
2. Night Time is reckoned between 10.00 PM to 6.00 AM
3. Silence Zone is defined as an area up to 100m around premises of Hospitals, Educational Institutions and Courts. Use of vehicle
horn, loudspeaker and bursting of crackers is banned in these zones.
Note: Mixed categories of areas be declared as one of the four above mentioned categories by the competent Authority and
the corresponding standards shall apply
Source: Central Pollution Control Board Norms
*As Per Noise Pollution (Regulation and Control) Rules, 2000
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 96 JM EnviroNet Pvt. Ltd.
Figure 3.14 (A): Graph showing Noise Levels at different locations during day time
Figure 3.14 (B): Graph showing Noise Levels at different locations during night time
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 97 JM EnviroNet Pvt. Ltd.
Conclusion
Ambient noise levels were measured at 12 locations around the plant and mine site. Noise levels
varies from 50.2 to 63.2 Leq dB (A) during day time and from 39.4 to 57.1 Leq dB (A) during night
time.
From the above study and discussions, it can be concluded that noise levels in the study area are
well within the prescribed limits as prescribed by the CPCB.
3.10 WATER ENVIRONMENT
3.10.1 Surface Water
Few surface water bodies are present within 10 km radius of the plant and mine site, which are as
follows:
Lilri River (~1.5 km in North direction)
Sukri River (~8.0 km in SSW direction)
Surface water samples were not collected from the above two locations as both the water bodies
are seasonal and were found dry during the study period.
3.10.2 Ground Water Quality
The sources of potable water are the tube-wells and dug-wells in the area. Samples were collected
from the available water resources around the plant site. The samples were collected and tested
from different sites.
The quality of ground water was studied by collecting nine water samples from representative
open dug wells and tube wells. The water sampling stations are shown below:
Details of ground water sampling locations and their distance and directions are given in Table -
3.14 and shown in Figure - 3.15.
Ground water analysis results are given in Table - 3.15.
Table - 3.14
Locations of Ground Water Sampling Stations
S. No. Sampling Station
Plant site Mine site
Approx. Aerial
DistanceDirection
Approx. Aerial
DistanceDirection
S1 Plant Site - - Adjacent E
S2 Nimbeti Mine site Adjacent W - -
S3 Village Kanyakheri 2.5 Km NE 3.0 ENE
S4 Village Patan 3.0 km West 1.5 Km West
S5 Village Bhimgarh 1.0 Km SE 1.2 Km East
S6 Village Ras 3.0 Km North 2.8 km NNE
S7 Village Mahesiya 11.0 Km SW 8.0 Km SW
S8 Village Nimbeti 0.5 Km NW 1.5 Km North
S9 Village Ramgarh 8.5 Km East 9.5 Km East
Source: SOI Toposheet
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 98 JM EnviroNet Pvt. Ltd.
Source: SOI Toposheet
Figure 3.15: Key Plan showing Ground Water and Soil Sampling Locations
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 99 JM EnviroNet Pvt. Ltd.
Table - 3.15
Ground Water Analysis
Study Period: Summer Season (March to May, 2015)
S. No. Parameters
Locations of Ground Water Sampling Limits of IS: 10500 - 2012
RemarkPlant Site
Nimbeti
Mine Site
Village
Kanyakheri
Village
Patan
Village
Bhimgarh
Village
Ras
Village
Mahesiya
Village
Nimbeti
Village
Ramgarh
Desirable
limit (Max.)
Permissible limit
in the Absence
of Alternate
Source (Max.)
1. pH 7.25 7.08 7.32 7.38 7.12 7.46 7.40 7.56 7.39 6.5 to 8.5 No Relaxation -
2. Colour (Hazen Units) BDL BDL BDL BDL BDL BDL BDL BDL BDL 5.0 15 DL 5 Hazen
3. Turbidity (NTU) BDL BDL BDL BDL BDL BDL BDL BDL BDL 1.0 5 DL 1 NTU
4. Odour Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable -
5. Taste Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable -
6.Total Hardness as CaCO3
(mg/l)410.22 542.20 581.12 577.92 417.96 380.56 405.30 360.80 541.80 200 600 -
7. Calcium as Ca (mg/l) 89.20 135.20 160.86 144.77 128.91 98.89 105.22 102.30 150.62 75 200 -
8. Alkalinity as CaCO3 (mg/l) 356.20 289.20 297.62 314.92 343.50 314.00 364.00 356.20 347.39 200 600 -
9. Chloride as Cl (mg/l) 476.20 387.65 205.79 477.07 143.57 356.20 278.52 245.20 234.50 250 1000 -
10. Cyanide as CN (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.05 No Relaxation DL 0.02 mg/l
11. Magnesium as Mg (mg/l) 45.60 49.78 43.68 52.66 23.41 32.52 34.69 25.65 40.34 30 100 -
12. TDS (mg/l) 1425 1245 1140 1489 1078 1142 1025 978 1050.0 500 2000 -
13. Sulphate as SO4 (mg/l) 114.67 117.83 106.00 91.67 88.33 174.20 98.00 76.67 78.33 200 400 -
14. Fluoride as F (mg/l) 1.18 1.24 1.26 1.38 1.21 1.28 0.98 1.06 1.23 1.0 1.5 -
15. Nitrate as NO3 (mg/l) 15.23 14.28 13.02 15.17 9.77 18.37 17.19 15.26 9.30 45 No Relaxation DL 0.10 mg/l
16. Iron as Fe (mg/l) 0.11 0.16 0.18 0.13 0.22 0.25 0.28 0.29 0.32 0.3 No Relaxation -
17. Aluminium as Al (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.03 0.2 DL 0.03 mg/l
18. Boron (mg/l) 0.52 0.48 0.58 0.79 0.52 0.68 0.64 0.64 0.40 0.50 1.0 DL 0.2 mg/l
19.Phenolic Compounds
(mg/l)BDL BDL BDL BDL BDL BDL BDL BDL
BDL0.001 0.002 DL 0.001 mg/l
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 100 JM EnviroNet Pvt. Ltd.
S. No. Parameters
Locations of Ground Water Sampling Limits of IS: 10500 - 2012
RemarkPlant Site
Nimbeti
Mine Site
Village
Kanyakheri
Village
Patan
Village
Bhimgarh
Village
Ras
Village
Mahesiya
Village
Nimbeti
Village
Ramgarh
Desirable
limit (Max.)
Permissible limit
in the Absence
of Alternate
Source (Max.)
20. Anionic Detergents (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.2 1.0 DL 0.002 mg/l
21.Hexa Chromium as Cr+6
(mg/l)BDL BDL BDL BDL BDL BDL BDL BDL
BDL- - DL 0.03 mg/l
22. Zinc as Zn (mg/l) BDL 0.15 BDL BDL BDL 0.17 BDL BDL BDL 5 15 DL 0.10 mg/l
23. Chromium as Cr (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.05 No Relaxation DL 0.002 mg/l
24. Copper as Cu (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.05 1.5 DL 0.02 mg/l
25. Manganese as Mn (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.1 0.3 DL 0.10 mg/l
26. Cadmium Cd (mg/l) BDL BDL BDL BDL BDL BDL BDL BDLBDL
0.003 No RelaxationDL 0.0005
mg/l
27. Lead as Pb (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.01 No Relaxation DL 0.008 mg/l
28. Arsenic as As (mg/l) BDL BDL BDL BDL BDL BDL BDL BDLBDL
0.01 0.05DL 0.0005
mg/l
29. Mercury as Hg (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.001 No Relaxation DL 0.001 mg/l
30. Sodium as Na (mg/l) 345.00 240.00 230.00 365.00 240.00 220.00 168.00 178.00 168.10 -- --
31. Potassium as K (mg/l) 16.20 10.25 8.90 13.20 8.10 4.00 10.20 7.10 9.20 -- --
32. Phosphate as PO4 (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL - - DL 0.02 mg/l
33. Nickel as Ni (mg/l) BDL BDL BDL BDL BDL BDL BDL BDL BDL 0.02 No Relaxation DL 0.005 mg/l
34. Conductivity, µS/cm 2140 1897 1726 2215 1605 1702 1510 1465 1602 - - -
Source: Water Analysis
BDL - Below Detectable LimitDL - Detection Level
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 101 JM EnviroNet Pvt. Ltd.
Results of Ground Water Analysis
Analysis results of ground water reveal the following: -
pH varies from 7.08 to 7.56
Total hardness varies from 360.80 to 581.12 mg/l
Total dissolved solids vary from 978 to 1489 mg/l
3.11 SOIL ENVIRONMENT
3.11.1 Soil Quality and Characteristics
The information on soil quality has been arrived at by collecting data from various secondary
sources and supplemented by collection and analysis of soil samples from representative
locations.
In order to assess the base line characteristics of soil profile of the plant area representing project
and nearby areas, the samples were analyzed for key and chemical parameters.
The sampling locations were finalized with the following considerations:
To enable information on baseline characteristics and,
To determine the impact of industrial and mining activities on soil characteristics.
Representative soil samples were collected from 9 different specified locations within the study
area of the plant site. Standard procedures were followed for the sampling and analysis of
physico-chemical parameters.
Location of soil sampling stations are given in Table - 3.16 and shown in Figure - 3.15.
Soil analysis results are given in Table - 3.17 and Standard Soil Classification is given in Table - 3.18.
Table - 3.16
Locations of Soil Sampling Stations
S. No. Sampling Station
Plant site Mine site
Approx. Aerial
DistanceDirection
Approx. Aerial
DistanceDirection
S1 Plant Site - - Adjacent E
S2 Nimbeti Mine site Adjacent W - -
S3 Village Kanyakheri 2.5 Km NE 3.0 ENE
S4 Village Patan 3.0 km West 1.5 Km West
S5 Village Bhimgarh 1.0 Km SE 1.2 Km East
S6 Village Ras 3.0 Km North 2.8 km NNE
S7 Village Mahesiya 11.0 Km SW 8.0 Km SW
S8 Village Nimbeti 0.5 Km NW 1.5 Km North
S9 Village Ramgarh 8.5 Km East 9.5 Km East
Source: SOI Toposheet
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 102 JM EnviroNet Pvt. Ltd.
Table - 3.17
Soil Analysis
Study Period: Summer Season (March to May, 2015)
S. No. Parameters
Sampling Locations
Plant SiteNimbeti
Mine Site
Village
Kenyakheri
Village
Patan
Village
Bhimgarh
Village
Ras
Village
Mahesiya
Village
Nimbeti
Village
Ramgarh
1. pH (1: 2.5 soil water sus.) 7.46 7.58 7.48 7.55 7.26 7.54 7.44 7.42 7.42
2. Conductivity (mS/cm) 0.20 0.23 0.24 0.22 0.23 0.21 0.22 0.21 0.25
3. Texture Sandy Clay Sandy Clay Sandy Clay Sandy Clay Sandy Clay Sandy Clay Sandy Clay Sandy Clay Sandy Clay
4. ColourYellowish
Brown
Yellowish
Brown
Yellowish
Brown
Yellowish
Brown
Yellowish
Brown
Yellowish
Brown
Yellowish
Brown
Yellowish
Brown
Yellowish
Brown
5. Water Holding Capacity (%) 26.21 28.10 27.30 27.14 25.14 23.44 24.14 26.20 25.61
6. Bulk Density(gm/Cc) 1.38 1.36 1.37 1.36 1.39 1.40 1.39 1.38 1.37
7. Chloride as Cl (mg/kg) 277.57 305.29 325.43 268.00 287.15 258.43 277.57 296.72 331.72
8. Calcium as Ca (mg/kg) 242.44 255.35 322.96 442.00 366.73 333.90 385.33 314.87 250.10
9. Sodium as Na (mg/kg) 28.0 30.00 47.00 40.00 45.00 34.00 48.00 54.00 44.00
10. Potassium as K (kg/ha) 124.72 132.64 134.41 119.52 162.08 142.72 197.28 186.40 178.96
11. Organic Matter (%) 0.40 0.65 0.62 0.67 0.57 0.56 0.58 0.60 0.57
12. Magnesium as Mg (mg/kg) 44.21 38.43 39.48 43.69 41.53 35.10 38.95 37.82 48.95
13. Available Nitrogen as N (kg/ha) 174.89 208.69 202.68 223.98 198.40 185.47 187.91 195.42 176.38
14.Available Phosphorus as P
(kg/ha)14.93 17.84 16.59 18.67 17.84 19.08 17.42 18.04 17.01
15 Zinc as Zn (mg/kg) 5.47 4.99 8.46 7.10 8.14 7.28 8.12 6.89 7.18
16. Manganese as (mg/kg) 121.74 175.41 140.21 146.23 154.41 196.41 201.40 174.60 180.30
17. Chromium as Cr (mg/kg) 3.42 4.89 2.86 3.10 4.21 5.10 4.30 5.23 5.12
18. Lead as Pb (mg/kg) 1.16 2.10 1.00 1.45 1.87 2.14 1.96 1.56 2.10
19. Cadmium as Cd (mg/kg) 1.38 1.24 1.06 2.10 2.43 2.06 1.86 1.44 2.44
20. Copper as Cu (mg/kg) 9.15 8.14 7.28 8.10 10.26 9.41 12.14 13.24 12.34
21. Organic Carbon (%) 0.23 0.38 0.36 0.39 0.33 0.32 0.34 0.35 0.33
Source: Soil Analysis
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 103 JM EnviroNet Pvt. Ltd.
Table - 3.18
Standard Soil Classification
S. No. Parameters Classification
1. pH <4.5 extremely acidic
4.51 5.0 very strong acidic
5.01 5.5 strongly acidic
5.51-6.0 moderately acidic
6.1 6.5 slightly acidic
6.51-7.3 Neutral
7.31-7.8 slightly alkaline
7.81-8.5 moderately alkaline
8.51 9.0 strongly alkaline
>9.0 Very strongly alkaline
2. Salinity Electrical Conductivity (mho/cm)
1 mho/cm = 640 ppm
Up to 1.0 average
1-2 harmful to germination
2-3 harmful to crops
3. Nitrogen (kg/ha) Up to 50 very less
51-100 less
110-150 good
151-300 better
>300 sufficient
4. Phosphorus (kg/ha) Up to 15 very less
15 30 less
31-50 medium
51-65 on average sufficient
66-80 sufficient
>80 more than sufficient
5. Potassium (kg/ha) 0-120 very less
120-180 less
180-240 medium
241-300 average
301-360 better
>360 more than sufficient
Conclusion
Samples collected from identified locations indicate pH value ranging from 7.26 to 7.58 , which
shows that the soil is neutral to moderately alkaline in nature. Organic Matter ranges from 0.40%
to 0.67% in the soil samples. Nitrogen is found to be in moderate amount as it ranges from 174.89
kg/ha to 223.98 kg/ha and Phosphorous in less amount i.e. from 14.93 kg/ha to 19.08 kg/ha,
whereas the Potassium is found to be ranging from 119.52 kg/ha to 197.28 kg/ha.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 104 JM EnviroNet Pvt. Ltd.
3.12 BIOLOGICAL ENVIRONMENT
3.12.1 Introduction
The biological study is essential to understand the impact of industrialization and urbanization on
existing flora and fauna of the study area. Studies on various aspects of ecosystem play an
important role in identifying sensitive issues for undertaking appropriate action to mitigate the
impact, if any.
The biological study was undertaken as a part of the EIA study report to understand the present
status of ecosystem prevailing in the study area, to compare it with past condition with the help
of available data, to predict changes in the biological environment as a result of present activities
and to suggest measures for maintaining its health.
A baseline study / survey was conducted to study the floristic and faunal diversity of the terrestrial
and aquatic environment of the study area within 10 km radius of the plant and mine site.
Some of the information was gathered from the local habitants. All the collected data were
classified to interpret the impact of pollution on the flora and fauna of that region.
Survey of the wild plants as well as cultivated crop plants was made and all the available
information was recorded. Night survey was also conducted with the help of spotlight to record
nocturnal animals, birds and reptiles.
Secondary data on flora and fauna, cropping patterns etc. were also collected from available
literatures, internet, forest department and revenue department.
3.12.2 Ecological Sensitive Area
No National Park, Wildlife Sanctuary, Biosphere Reserve exists within 10 km radius of the plant
site.
Only one Reserve Forest falls at a distance of ~5.0 km in SSE direction from the plant site and one
Protected Forest falls at a distance of ~9.9 Km in SE direction from the plant site.
3.12.3 Flora
Flora of an area depends on climatic conditions, topography, rainfall, soil type, land use and
demography of an area. These factors highly affect the floral cover and quality of an area.
A floral survey was carried out in the core as well as buffer zone of the plant and mine site. The
plant species found in the area are given in Table - 3.19.
Table - 3.19
List of Flora in Core and Buffer Area
S. No. Scientific Name Local Name Family Habit Core Buffer
Trees
1. Acacia auriculiformis Australian babool Mimosaceae T + +
2. Acacia catechu Khair Mimosaceae T - +
3. Acacia nilotica Babool Mimosaceae T - +
4. Ailanthus excelsa Ardu/Paba Simaroubaceae T + +
5. Alstonia scholaris Saptaparni Apocynaceae T + +
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 105 JM EnviroNet Pvt. Ltd.
S. No. Scientific Name Local Name Family Habit Core Buffer
6. Albizia Julibrissin Silk tree Fabaceae T + +
7. Ashoka pendula Ashok Annonaceae T + +
8. Azadirachta indica Neem Meliaceae T + +
9. Bauhinia blakeana Kachnar Fabaceae T + +
10. Bauhinia racemosa Jhinja Caesalpiniaceae T - +
11. Boswellia serrata Salar Burseraceae T - +
12. Butea monosperma Palas Fabaceae T - +
13. Balanites aegyptiaca Hingot Simaroubaceae T - +
14. Callistemon lanceolatus Bottle brush Myrtaceae T + +
15. Cassia fistula Amaltas Caesalpiniaceae T + +
16. Delonix regia Gulmohar Fabaceae T + +
17. Dalbergia sissoo Shisham Fabaceae T + +
18. Dichrostachys cinerea Khairi Mimosaceae T - +
19. Diospyros melanoxylon Tendu Ebenaceae T - +
20. Emblica officinalis Amla Phyllanthaceae T - +
21. Erythrina indica Indian Coral tree Fabaceae T + +
22. Ficus benghalensis Bad Moraceae T - +
23. Ficus religiosa Aswatha/Pipal Moraceae T - +
24. Jacaranda mimosisolia Blue Gulmohar Fabaceae T + +
25. Kigelia pinnata Balamkheera Bignoniceae T + +
26. Lannea coromandelica Mohin Anacardiaceae T - +
27. Lagerstroemia indica Largestomia Lythraceae T + +
28. Mimusops Elengi Molshree plant Sapotaceae T + +
29. Peltophorum ferrugineum Yellow Gulmohar Fabaceae T + +
30. Phoenix sylvestris Khajur Arecaceae T + +
31. Pithecellobium dulce Jungle Jalebi Fabaceae T + +
32. Pongamia pinnata Karanj Fabaceae T + +
33. Prosopis cineraria Khejri Fabaceae T - +
34. Pterospermum acerifolium Kanak Champa Sterculiaceae T - +
35. Salvadora persica Chota Pilu/ Khara Jal Salvadoraceae T - +
36. Salvadora oleoides Bada Pilu/ Mitha Jal Salvadoraceae T - +
37. Sterculia urens Kulu Sterculiaceae T - +
38. Tamarindus indica Imli Fabaceae T - +
39. Terminalia catappa Desi badam Combretaceae T + +
40. Wrightia tinctoria Khirni Apocynaceae T - +
Shrubs
41. Bauhinia tomentosa Kachnar Apocynaceae S + +
42. Bougainvillea glabra Bougainvillea Nyctaginaceae S + +
43. Caesalpinia pulcherrima Peacock flower Fabaceae S + +
44. Capparis decidua Ker Capparaceae S - +
45. Cassia biflora Desert Cassia Fabaceae S + +
46. Ficus panda Golden Ficus Moraceae S + +
47. Ficus starlight Ficus starlight Moraceae S + +
48. Euphorbia neriifolia Dandathor Euphorbiaceae S - +
49. Grewia flavescens Donkey berry Tiliaceae S - +
50. Grewia tenax Gangan Tiliaceae S - +
51. Hibiscus rosa sinensis Gudahal Malvaceae S + +
52. Jatropha curcas Ratanjot Euphorbiaceae S + +
53. Lawsonia inermis Mehndi Lythraceae S - +
54. Leptadenia reticulata Kheep Asclepiadecae S - +
55. Nerium oleander Red Kaner Apocynaceae S + +
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 106 JM EnviroNet Pvt. Ltd.
S. No. Scientific Name Local Name Family Habit Core Buffer
56. Nyctanthes arbor- tristis Harsingar Oleaceaae S + +
57. Prosopis juliflora Kikar/Vilayati Babul Fabaceae S - +
58. Rhus mysorensis Dansri Anacardiaceae S - +
59. Securinega leucopyrus Shinar Euphorbiaceae S - +
60. Tabernaemontana divaricata Chandani Apocynaceae S + +
61. Tecoma Stans Yellow bells Bignoniceae S + +
62. Thevetia peruviana Yellow Kaner Apocynaceae S + +
63. Ziziphus mauritiana Mota Ber Rhamnaceae S - +
Herbs
64. Aerva tomentosa Buida Amaranthaceae H - +
65. Achyranthes aspera Undhokanto Amaranthaceae H - +
66. Boerhavia diffusa Santhi Nyctaginaceae H - +
67. Calotropis procera Aak Asclepiadaceae H + +
68. Convolvulus microphyllus Shankh Pusphi Convolvulaceae H - +
69. Citrullus colocynthis Gar- Tumba Cucurbitaceae H - +
70. Citrullus lanatus Matira Cucurbitaceae H - +
71. Crotalaria burhia Shinio Fabaceae H - +
72. Cucumis callosus Kachari Cucurbitaceae H - +
73. Cucumis prophetarum Kantala Indranan Cucurbitaceae H + +
74. Euphorbia prostrata Lal Booti Euphorbiaceae H - +
75. Echinops echinatus Oont Kantilo Asteraceae H - +
76. Gisekia pharnaceoides Mulandege Ficoidaceae H - +
77. Heliotropium ellipticum Hati Sund Boraginaceae H - +
78. Martynia annua Bichhu Kanto Martyniaceae H - +
79. Polycarpaea corymbosa Dholi Phuli Caryophyllaceae H - +
80. Pedalium murex Dakhni Gokhru Pedaliaceae H - +
81. Solanum surattense Pasarghatali Solanaceae H - +
82. Solanum nigrum Makoi Solanaceae H - +
83. Tribulus terrestris Kanti/Gokhru Zygophyllaceae H - +
84. Tephrosia purpurea Dhamaso Fabaceae H - +
Grasses
85. Calligonum polygonoides Phog Polygonaceae G - +
86. Cynodon dactylon Doob Poaceae G + +
87. Cenchrus biflorus Bhurat Poaceae G - +
88. Eragrostis curvula - Poaceae G - +
89. Mollugo cerviana Chirio Ghas Molluginaceae G - +
90. Saccharum munja Munj Poaceae G - +
Weeds
91. Argemone mexicana Pili Kateri Papaveraceae W + +
92. Datura metal Dhatura Solanaceae W - +
93. Euphorbia hirta Dudhi Euphorbiaceae W + +
94. Lantana camara Ghaneri Verbenaceae W - +
95. Leucas aspera Darkan Lamiaceae W + +
96. Leucas martinicensis Darkan Lamiaceae W - +
97. Xanthium strumarium Bichhu Butti Asteraceae W + +
Source: Field Survey and Secondary data
Status of RET Species
According to Botanical Survey of India, no Endemic, Rare, Endangered and Threatened (RET)
species of flora were found in the study area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 107 JM EnviroNet Pvt. Ltd.
3.12.4 Fauna
A faunal survey was carried out in the core as well as buffer zone of the plant and mine site.
Details of faunal species found in the area are given in Table - 3.20.
Table - 3.20
List of Fauna
S. No. Scientific Name Common NameStatus according to
WPA, 1972Core Buffer
Mammals
1. Boselaphus tragocamelus Nilgai Sch. III - +
2. Bandicota bengalensis Indian Mole Rat Sch. V - +
3. Felis chaus Jungle Cat Sch. V - +
4. Funambulus pennanti Five Striped Palm Squirrel Sch. IV + +
5. Herpestes auropunctatus Small Indian Mongoose Sch. II - +
6. Hystrix indica Indian Porcupine Sch. IV - +
7. Lepus nigricolis Indian Hare Sch. IV - +
8. Mus booduga Indian Field Mouse Sch. V - +
9. Pteropus giganteus Flying Fox Sch. V - +
10. Rattus rattus House Rat Sch. V + +
11. Sus scrofa Indian Wild Boar Sch. III - +
Avifauna (Birds)
1. Acridotheres tristis Common Myna Sch. IV + +
2. Acridotheres ginginianus Bank Myna Sch. IV - +
3. Athena brahma Spotted owlet Sch. IV - +
4. Ardeola grayii Indian Pond Heron Sch. IV + +
5. Bubulcus ibis Cattle egret Sch. IV + +
6. Corvus splendens Common Crow Sch. V + +
7. Columba livia Blue Rock Pigeon Sch. IV + +
8. Cuculus micropterus Indian Cuckoo Sch. IV - +
9. Centropus sinensis Crow pheasant Sch. IV - +
10. Ceryle rudis Lesser Pied Kingfisher Sch. IV - +
11. Coracias benghalensis Indian Roller Sch. IV - +
12. Dendrocitta vagabunda Indian Treepie Sch. IV - +
13. Dicrurus macrocercus Black Drongo Sch. IV - +
14. Egretta garzetta Little Egret Sch. IV - +
15. Eudynamys scolopacea Indian Koel Sch. IV - +
16. Galerida cristata Common Crested Lark Sch. IV - +
17. Halcyon smyrnensis White-breasted Kingfisher Sch. IV + +
18. Himantopus himantopus Black Winged Stilt Sch. IV - +
19. Merops orientalis Small Bee Eater Sch. IV + +
20. Nectarinia asiatica Purple Sunbird Sch. IV - +
21. Passer domesticus House Sparrow Sch. IV + +
22. Platalea leucorodia Eurasian Spoonbill Sch. IV - +
23. Pycnonotus cafer Red-Vented Bulbul Sch. IV + +
24. Phalacrocorax niger Little Cormorant Sch. IV - +
25. Psittacula krameri Rose Ringed Parakeet Sch. IV + +
26. Psittacula cyanocephala Plum headed Parakeet Sch. IV + +
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 108 JM EnviroNet Pvt. Ltd.
S. No. Scientific Name Common NameStatus according to
WPA, 1972Core Buffer
27. Saxicoloides fulicata Indian Robin Sch. IV + +
28. Sturnus pagodarum Brahminy Starling Sch. IV - +
29. Sturnus contra Asian Pied Starling Sch. IV - +
30. Streptopelia tranquebarica Red Collared Dove Sch. IV + +
31. Streptopelia decaocto Eurasian Collared Dove Sch. IV - +
32. Turdoides malcomi Large Grey Babbler Sch. IV - +
33. Tringa totanus Common Redshank Sch. IV - +
34. Upupa epops Common Hoopoe Sch. IV + +
35. Vanellus indicus Red-Wattled Lapwing Sch. IV + +
Herpeto-fauna
1. Bufo melanostictus Common Indian Toad Sch. IV + +
2. Bungarus caeruleus Common krait Sch. IV - +
3. Calotes versicolor Garden Lizard Sch. IV + +
4. Echis carinatus Saw scaled viper Sch. IV - +
5. Eumeces taeniolatus Yellow billedmoled skink Sch. IV - +
6. Hemidactylus maculatus Rock Gecko Sch. IV - +
7. Ptyas mucosa Indian Rat Snake Sch. II - +
8. Rana tigerina Indian Bull Frog Sch. IV + +
9. Rana hexadactyla Green Pond Frog Sch. IV - +
10. Rana limnocharis Indian Cricket Frog Sch. IV - +
11. Xenochrophis piscator Chequered Keel Back Sch. II - +
Source: Field Survey and Secondary data
S. No. Scientific Name Common Name Core Buffer
Butterflies & Other Ancillary Arthropods
1. Anaphaeis aurota Pioneer - +
2. Acisoma panorpoidea Trumpet tail - +
3. Buthus sp. Scorpion + +
4. Brachythemis sp. Ditch Jewel - +
5. Belostoma indicum Indian giant water Bug - +
6. Catopsilia pomona Common Emigrant + +
7. Danaus chrysippus Plain Tiger + +
8. Ixias Marianne White Orange Tip - +
9. Precis hierta Yellow Pansy + +
10. Precis orithya Blue Pansy - +
11. Sternocerca sternicornis Jewel Beetle - +
12. Stegodyphus sp. Social Spider - +
Source: Field Survey and Secondary data
Status of Fauna
The biological study conducted for the core as well as buffer zone of the plant and mine site
reveals that the fauna found in the study area majorly belongs to Schedule II, III, IV and V. No
Schedule - I fauna as per (IWPA) Indian Wildlife Protection Act, 1972 was recorded in the study
area during field survey.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 109 JM EnviroNet Pvt. Ltd.
3.13 SOCIO-ECONOMIC ENVIRONMENT
Socio-economic environment is an essential part of environmental study which incorporates
various facts related to socio-economic conditions in the area and deals with the total
environment.
Socio - economic study includes demographic structure of the area, provision of basic amenities
viz. housing, education, health and medical services, occupation, water supply, sanitation,
communication, transportation, prevailing diseases pattern as well as feature of aesthetic
significance such as temples, historical monuments etc. at the baseline level. This would help in
visualizing and predicting the possible impact depending upon the nature and magnitude of the
project.
Socio-economic study of an area provides a good opportunity to assess the socio-economic
conditions of an area. This study will possibly estimate the change in living and social standards of
the particular area benefitted due to the project. The gross economic production of the area will
be increased substantially due to the existence of this project. It can undoubtedly be said that this
plant will provide direct and indirect employment and improve the infrastructural facilities and
living standards of the area.
The fabrics of socio-economic changes are so complicated that this study would seem to be
extremely limited, almost superficial and at times subjective in nature. This EIA will give a
reasonably clear picture of the socio-economic conditions prevailing in the study area.
3.13.1 Objectives of the Study
The objectives of this socio-economic report consist of:
To know the current socio-economic situation in the region
To recommend practical strategic interventions in the sector
To help in providing better living standards
3.13.2 Scope of Work
To study the Socio-economic Environment of area from the secondary sources
Prediction of project impact
Mitigation Measures
3.13.3 Methodology
Collection of Data
Data for this project were collected via secondary source (i.e. Government department, maps,
literature research etc.) in the study area.
Presentation of Data and Analysis
The data collected were presented in a suitable, concise form for further analysis. The collected
data were presented in the form of tabular or diagrammatic or graphic form. These tabulated data
were interpreted and analyzed with the help of various qualitative techniques and ideographic
approaches.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 110 JM EnviroNet Pvt. Ltd.
3.13.4 Background Information of the Area
Pali is the 14th most populated district in the state of Rajasthan. Pali also ranks 7th in terms of area
and 28th in terms of population density. Pali District is situated in western Rajasthan. A zone of
foothills lies to the west, through which run the many tributaries of the Luni River. In Pali district, 81
new villages have been created as compared to 2001 Census. The sex ratio of Pali district (987) is
significantly higher than the State sex ratio (928). The literacy rate in Pali district is 62.39 percent
which is lower than the State Average (66.11%). The district has shown significant spurt in industrial
activity, based on the exploitation of its agriculture and rich mineral deposits.
Table - 3.21
Socio-Economic Profile of Study Area
Particular Rajasthan Details Pali Details Study Area Details
Area (in sq. kms.) 3,42,239 12387 314
No. of Households 1,27,11,146 4,16,508 11344
Population 6,85,48,437 20,37,573 56332
Male 3,55,50,997 10,25,422 28818
Female 3,29,97,440 10,12,151 27514
Scheduled Tribes 92,38,534 1,44,578 3510
Scheduled Castes 1,22,21,593 3,98,096 10090
Literacy 66.11% 62.39% 53.12%
Sex Ratio (Females per 1000 Males) 928 987 955
Source: Census of India, 2011
3.13.5 Baseline Data and Analysis
The socio-economic study has been conducted on the basis of secondary data available. The
study area was categorized on the basis of the distance of the villages from plant site. Primary
zone was identified from 0 to 3 km radius area, Secondary zone in 3 to 5 km and Outer zone in 5
to 10 km radius area from the plant & mine site. Information were collected from the data of
census 2011 and the secondary information collected from various government departments like
health department, agriculture department, IMD etc.
3.13.6 Demographic Profile of the Study Area
The population as per 2011 Census records is 56332 (for 10 km radius buffer zone). Table - 3.22
shows demographic profile of study area that total no. of household is 1163, 3630 and 6551
respectively in primary, secondary and outer zone. Sex ratio is 951, 936 and 967 (females per 1000
males) observed in primary, secondary and outer zone respectively. SC population distribution is
777, 3492 and 5821 respectively in primary, secondary and outer zone. ST population distribution is
2722, 19 and 769 respectively in primary, secondary and outer zone respectively. Literacy rate is
35.05%, 53.75% and 56.10% in primary, secondary and outer zone respectively. Average household
size is 4.96. Demographic profile of study area is given in table 3.22 below:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 111 JM EnviroNet Pvt. Ltd.
Table - 3.22
Socio-Economic Profile of Study Area (Plant and Mine)
S.
No.
Village
Name
No. of
Household
Total
Population
Total
Male
Total
Female
Sex
Ratio
SC
Population
ST
Population
Literacy
Rate (%)
Total
Working
Population
Total Main
Worker
Total
Marginal
worker
Total Non-
Worker
Population
0 - 3 km
1. Village Bhimgarh 409 2143 1117 1026 919 546 6 43.95 717 566 151 1426
2. Village Kundal 493 2717 1388 1329 957 9 2687 23.06 1387 715 672 1330
3. Village Patan 222 1189 591 598 1012 222 0 42.35 390 383 7 799
4. Village Kerpura 39 160 87 73 839 0 29 57.89 42 38 4 118
SUB - TOTAL 1163 6209 3183 3026 951 777 2722 35.05 2536 1702 834 3673
3 - 5 km
1.Village Ramawas
Khurd216 997 477 520 1090 202 0 51.70 502 189 313 495
2. Village Butiwas 635 3356 1762 1594 905 867 0 49.73 1641 1318 323 1715
3. Village Ras 1881 9511 4973 4538 913 1765 3 60.21 3389 2686 703 6122
4. Village Pratabgarh 260 1051 510 541 1061 311 0 45.21 518 186 332 533
5. Village Devgarh 176 900 444 456 1027 122 0 34.58 534 354 180 366
6. Village Pratabgarh 369 1828 959 869 906 145 16 41.21 1052 513 539 776
7. Village Gopalpura 93 465 230 235 1022 80 0 60.52 122 108 14 343
SUB - TOTAL 3630 18108 9355 8753 936 3492 19 53.75 7758 5354 2404 10350
5 - 10 km
1. Village Paliyawas 283 1400 730 670 918 107 0 47.06 499 391 108 901
2. Village Rupnagar 102 449 210 239 1138 10 8 51.73 129 114 15 320
3. Village Tunkra 368 1685 834 851 1020 368 0 40.36 823 636 187 862
4. Village Nayagaon 148 671 358 313 874 55 464 42.91 388 214 174 283
5. Village Babra 861 4118 2126 1992 937 787 254 62.65 1791 1518 273 2327
6. Village Ramgarh 173 1072 550 522 949 0 0 61.14 469 416 53 603
7. Village Chainpura 112 557 293 264 901 0 0 54.07 199 194 5 358
8. Village Dayalpura 206 1023 548 475 867 383 1 43.77 518 230 288 505
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 112 JM EnviroNet Pvt. Ltd.
S.
No.
Village
Name
No. of
Household
Total
Population
Total
Male
Total
Female
Sex
Ratio
SC
Population
ST
Population
Literacy
Rate (%)
Total
Working
Population
Total Main
Worker
Total
Marginal
worker
Total Non-
Worker
Population
9. Village Ballupura 185 997 502 495 986 291 0 49.81 339 261 78 658
10. Village Rabariyawas 1050 5380 2793 2587 926 856 16 60.40 1783 1611 172 3597
11. Village Nimbera Khurd 164 819 407 412 1012 331 2 59.22 364 361 3 455
12. Village Chaundiya 540 2385 1123 1262 1124 641 11 55.62 1146 679 467 1239
13.Village Khera
Mamawas227 1080 529 551 1042 207 0 51.16 657 574 83 423
14. Village Girri 619 3011 1532 1479 965 1052 0 65.68 1149 958 191 1862
15. Village Nanana 460 2253 1144 1109 969 235 0 56.94 1024 992 32 1229
16. Village Shyampura 183 754 374 380 1016 1 1 50.42 330 235 95 424
17. Village Bhanwariya 225 1159 610 549 900 80 0 56.81 583 284 299 576
18. Village Patan 319 1607 858 749 873 183 12 48.73 587 438 149 1020
19. Village Kolpura 173 965 467 498 1066 110 0 55.40 431 216 215 534
20. Village Ramgarh 153 630 292 338 1158 124 0 57.49 338 221 117 292
SUB - TOTAL 6551 32015 16280 15735 967 5821 769 56.10 13547 10543 3004 18468
GRAND TOTAL 11344 56332 28818 27514 955 10090 3510 53.12 23841 17599 6242 32491
Source: Census of India, 2011
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 113 JM EnviroNet Pvt. Ltd.
3.13.6.1 Demographic Profile
The population as per 2011 Census records is 56332 (for 10 km radius buffer zone). Table - 3.23
shows demographic profile of study area that total no. of household is 1163, 3630 and 6551
respectively in primary, secondary and outer zone. Sex ratio is 951, 936 and 967 (females per 1000
males) observed in primary, secondary and outer zone respectively. Average household size is
4.96.
Table - 3.23
Demographic Profile of Study Area (Plant and Mine Site)
ZoneNo. of
Villages
Total
Household
Total
Population
Total Male
Population
Total Female
PopulationSex Ratio
Primary Zone (0 - 3 Km) 4 1163 6209 3183 3026 951
Secondary Zone (3 - 5 Km) 7 3630 18108 9355 8753 936
Outer Zone (5 - 10 Km) 20 6551 32015 16280 15735 967
Source: Census of India, 2011
Figure - 3.16: Demography Profile of the study area
3.13.6.2 Vulnerable Group
While developing an Action Plan, it is very important to identify the population who fall under
the marginalized and vulnerable groups and special attention has to be given towards these
groups while making action plans. Special provisions should be made for them. In the observed
villages, schedule caste (S.C.) population is 17.91% and Schedule Tribe population 6.23% in study
area while 75.85% of the population has been observed as others.
Table - 3.24
SC/ST Population of the Study Area
Zone No. of VillagesTotal
Household
Total
Population
SC
Population
ST
Population
Primary Zone (0 - 3 Km) 4 1163 6209 777 2722
Secondary Zone (3 - 5 Km) 7 3630 18108 3492 19
Outer Zone (5 - 10 Km) 20 6551 32015 5821 769
Total 31 11344 56332 10090 3510
Source: Census of India, 2011
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 114 JM EnviroNet Pvt. Ltd.
Figure 3.17: SC / ST Population within 10 Km Study Area
3.13.6.3 Literacy Rate
Literacy Rate is the percentage of people in the area with the ability to read and write. The analysis
of the literacy levels is done in the study area. The 10 km radius study area demonstrates a literacy
rate of 53.12% as per census data.
The male literacy rate in the study area works out to be 69.83% whereas the female literacy rate,
which is an important indicator for social change, is observed to be 35.82% in the study area as per
the census data 2011. This indicates that there is a need to focus in sociological aspect in the region
and enhance further development.
The distribution of literates and literacy rates in the observed village is given in Table- 3.25.
In the present study, the literacy rate is average level in the study area. Male and Female literacy
rate of villages are varying place to place. Although Female literacy rate in the region is coming
out low as compared to male.
Table - 3.25
Literacy Level of the Study Area
ZoneNo. of
Villages
No. of
Male
Literate
No. of
Female
Literate
Total
Literate
Population
Male
Literacy
Rate
Female
Literacy
Rate
Total
Literacy
Rate
Primary Zone (0 - 3 Km) 4 1273 454 1727 50.18 19.00 35.05
Secondary Zone (3 - 5 Km) 7 5408 2556 7964 71.03 35.48 53.75
Outer Zone (5 - 10 Km) 20 9859 5183 15042 72.84 39.03 56.1
Source: Census of India, 2011
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 115 JM EnviroNet Pvt. Ltd.
Figure - 3.18: Gender Wise Literacy Details
3.13.6.4 Economic Activities
The economy of an area is defined by the occupational pattern and income level of the people in
the area. The occupational structure of residents in the study area is studied with reference to
work category. The population is divided occupation wise into three categories, viz., main
workers, marginal workers and non-workers. The main workers include cultivators, agricultural
laborers, those engaged in household industry and other services.
The marginal workers are those engaged in some work for a period of less than 180 days during
the reference year. The non-workers include those engaged in unpaid household duties like,
students, retired persons, dependents, beggars, vagrants etc. besides institutional inmates or all
other non-workers who do not fall under the above categories.
Table - 3.26
Work Forces of the Study Area
Name of Villages Total Worker Main Worker Marginal Worker Non Worker
Primary Zone (0 - 3 Km)
Village Bhimgarh 717 566 151 1426
Village Kundal 1387 715 672 1330
Village Patan 390 383 7 799
Village Kerpura 42 38 4 118
Sub - Total 2536 1702 834 3673
Secondary Zone (3 - 5 Km)
Village Ramawas Khurd 502 189 313 495
Village Butiwas 1641 1318 323 1715
Village Ras 3389 2686 703 6122
Village Pratabgarh 518 186 332 533
Village Devgarh 534 354 180 366
Village Pratabgarh 1052 513 539 776
Village Gopalpura 122 108 14 343
Sub - Total 7758 5354 2404 10350
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 116 JM EnviroNet Pvt. Ltd.
Name of Villages Total Worker Main Worker Marginal Worker Non Worker
Outer Zone (5 - 10 Km)
Village Paliyawas 499 391 108 901
Village Rupnagar 129 114 15 320
Village Tunkra 823 636 187 862
Village Nayagaon 388 214 174 283
Village Babra 1791 1518 273 2327
Village Ramgarh 469 416 53 603
Village Chainpura 199 194 5 358
Village Dayalpura 518 230 288 505
Village Ballupura 339 261 78 658
Village Rabariyawas 1783 1611 172 3597
Village Nimbera Khurd 364 361 3 455
Village Chaundiya 1146 679 467 1239
Village Khera Mamawas 657 574 83 423
Village Girri 1149 958 191 1862
Village Nanana 1024 992 32 1229
Village Shyampura 330 235 95 424
Village Bhanwariya 583 284 299 576
Village Patan 587 438 149 1020
Village Kolpura 431 216 215 534
Village Ramgarh 338 221 117 292
Sub - Total 13547 10543 3004 18468
Grand Total 23841 17599 6242 32491
Source: Census of India, 2011
Figure 3.19: Working Details
The above table shows that the percentage of total working population and non-working
population is 42.3% and 57.7% respectively of whole population of observed villages. As per census
data 2011, the ratio of non-working population is more than working population in the study area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - III of Final EIA / EMP Report
M/s. Shree Cement Ltd. 117 JM EnviroNet Pvt. Ltd.
3.13.7 Conclusion
The socio economic study of the study area gives clear picture of its population, average
household size, literacy rate, sex ratio etc, the literacy rate is concerned the study area has an
average (53.12%). It has schedule tribe and schedule castes.
The study area as a whole possesses average of infrastructural facilities. However, in comparison
with the facilities available in other parts of the area has basic amenities like higher education,
health, drinking water and communication network. The area is well connected with road
transport and communication facilities.
3.14 INDUSTRIES FALLING WITHIN 10 KM RADIUS OF THE AREA
Few industries are located within 10 km radius of the plant site; these are listed as shown in the
table below:
Table - 3.27
Industries Falling Within 10 Km Radius of the Area
S.
No.Name of the Industry
Direction from
Plant Site
Approx. Distance
from Plant Site
3. Ambuja Cements Ltd. (Unit - Rabriyawas) NW 6 Km
Source: Field Survey
3.15 CONCLUSION
The environment baseline study was conducted in the project area by both secondary data and
primary data collections. Abiotic factors including air, water and soil were studied for the core and
buffer zone.
It was found that most of the parameters were within the limits as per the Indian Standards.
Similarly, the study for the biotic factors was conducted. It can be concluded that the present
environment status of the study area is good enough for the project expansion activity. Adoption
of adequate pollution control measures will protect the surrounding environment.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 118 JM EnviroNet Pvt. Ltd.
CHAPTER - IV
ANTICIPATED ENVIRONEMNTAL IMPACTS AND MITIGATION MEASURES
4.1 ENVIRONMENTAL IMPACT STUDY
The anticipated environmental impacts of the proposed expansion of cement project would be
mainly due to the construction and operational activities.
These operations can disturb the environment in various ways, such as change in air, noise level;
water and soil quality of that particular area. While for the purpose of development and economic
up-liftment of people, there is need for establishment of industries, but these have to be
environmental friendly. Therefore, it is essential to assess the impacts of proposed expansion
project on different environmental parameters, so that abatement measures could be planned in
advance for eco-friendly operation of Cement Project, Captive Thermal Power Plant and Synthetic
Gypsum Plant in the area.
4.2 IMPACT DUE TO PROPOSED EXPANSION ACTIVITY
Impacts due to any project activity have been divided according to the temporal scale into
Impacts during Construction Phase and Impacts during Operation Phase .
The impacts on different environmental parameters, due to the proposed expansion project, will
be due to various activities carried out during construction phase and operation phase;
Construction activity spreads over pre-construction, machinery installation and commissioning
stages and ends with the induction of manpower and start-up. During operation phase of the
proposed expansion project, the impacts will be mostly permanent and irreversible in nature.
4.3 ANTICIPATED IMPACTS DURING CONSTRUCTION PHASE
Total plant area is 231.54 ha (which includes 187.56 ha existing plant area and 43.98 ha additional
area within plant boundary); 72.7 ha area is also available outside the plant boundary for future
use. Proposed expansion will be done on additional area available within the plant boundary.
During construction, the activities related to land de-weeding, leveling of site and construction of
building structures and installation of machineries and equipments will lead to emission of
particulate matter. Construction activities during this stage will temporarily alter the environment
of the nearby area due to movement of heavy machineries and vehicles.
4.3.1 Impact on Topography and Land Use
Topography of the site is generally flat with an elevation range of 374 - 400 m. Some level of
cutting and filling will need to be done to maintain an even topography within the plant area. No
major change in topography of the site is envisaged due to proposed expansion project.
The present land use of the plant site is industrial; proposed expansion will be done on additional
area within the existing plant premises by, thus, there is no change of the land use of the area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 119 JM EnviroNet Pvt. Ltd.
Apart from the temporary change in soil profile within the plant site, there will not be any adverse
impact on the surrounding land use during the construction period.
4.3.2 Impact on Air Quality
Dust emissions are the major emissions during construction phase. The main sources of dust
emission are the movement of equipment at site, leveling, grading, earthwork and foundation
works. Exhaust emissions from vehicles and equipment to be deployed during the construction
phase is also likely to result in marginal increase in the levels of SO2, NOxand CO. The impact will be
for short duration. This will be confined within the plant boundary and is expected to be negligible
outside the plant boundary. The impact will, however, be reversible, marginal and temporary in
nature.
Construction equipment having PUC certificate will be deployed during the activity to restrict
exhaust emission. Proper maintenance of vehicles and construction equipment will help in
controlling the gaseous emissions. Water sprinkling on roads and construction site will prevent
fugitive dust.
In addition to above, dust will also be generated from stockpiles of construction material
(aggregates and sand). To prevent this, stockpiles will be aligned properly with slopes stabilized
and max. height will be maintained.
4.3.3 Impact on Noise Levels
During construction phase, noise will be generated due to following activities / processes:
Movement /operation of transport and construction vehicles / equipment
Transportation of equipment, materials and people
Other important activities involved in construction stage such as excavation, earthmoving,
compaction, concrete mixing, crane operation, steel erection, mechanical /electrical
installation
Piling work during laying down of foundation for infrastructure
The noise generation during construction phase will be temporary and will be limited to the plant
site. The vehicles used for movement will be taken for preventive maintenance to reduce noise
generation at source.
4.3.4 Impact on Water Resources and Water Quality
The water requirement during the construction phase will be approximately 200 KLD.
Groundwater will be stored in RCC tank / overhead and used in civil construction, canteen, besides
domestic use by construction workers. Construction workers will be brought from nearby villages.
About 20 KLD of wastewater will be generated from the construction site. The wastewater will be
taken to Soakpit and septic tank. The treated wastewater will be recycled for civil construction
and greenbelt development / plantation purpose. Storm water drains will be made immediately
after starting construction activity. The drains will be properly aligned in conformity with the site
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 120 JM EnviroNet Pvt. Ltd.
drainage pattern so that the alteration is kept to the minimum and flooding or soil erosion does
not occur.
Sedimentation pits will be provided at appropriate location to trap the silt laden runoff water and
prevent excessive silt from going outside. The storm water drains will be diverted to a water
reservoir to collect the runoff. This stored water will be utilized for civil construction purpose.
Thus, there will not be any discharge from the site which can have any impact on the water
quality.
4.3.5 Impact on Soil
During construction activity, the impact on soil will be limited to the construction site only. Impact
on soil during construction would be mainly due to the left out of construction material used.
Careful design, planning and good site management would minimize wastage of materials such as
concrete, mortars and cement grouts. Construction wastes will be segregated as much as possible
at site itself to increase the feasibility of recycling concrete and masonry as filling material and
steel pieces as saleable scrap.
Litter disposal and collection points will be established around the work sites. Empty packaging
materials, drums, glass, tin, paper, plastic, pet bottles, wood, thermocol and other packaging
materials, etc. will be disposed through recyclers (locally called kabadis). The construction spoils
will be temporarily stored at designated dumpsite located inside the plant premises.
4.3.6 Impact on Socio-Economic Environment
The social impact during the construction stage will be of beneficial nature. About 500 people will
get employment during the construction stage on daily average basis. Proposed expansion
project will result in growth of the surrounding areas by increased direct and indirect employment
opportunities in the region including ancillary development and supporting infrastructure.
Local people will be given preference for employment on the basis of their skill and experience.
Further, the project will also lead to the development of market, trade centers, activities etc.
4.4 ANTICIPATED IMPACTS DURING OPERATION PHASE AND PROPOSED MITIGATION MEASURES
The process involved in the proposed expansion of cement production capacity has varying
impacts on the different components of the environment. All these impacts will be considered for
impact assessment and accordingly the mitigation measures will be adopted. The design basis for
all process units will lay special emphasis on measures to minimize the impact at source itself.
4.4.1 Impact on Land Use Pattern
Total plant area is 231.54 ha and proposed expansion will be done on additional area available
within the existing plant premises. Therefore, no change in existing land use pattern within the
core zone is envisaged, except for green area, which will be increased during plant operation. At
present, plantation has been done in 63.8 ha (34%of the total existing plant area i.e. 187.5), and
additional 14.5 ha will be further developed for this proposed expansion.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 121 JM EnviroNet Pvt. Ltd.
4.4.2 Impact on Air Quality and Mitigation Measures
4.4.2.1 Impact due to operation of proposed expansion project
The operational phase of the proposed expansion project comprises of various activities each of
which will have an impact on air quality. The impact on air quality can be due to:
Fugitive emissions
Stack emissions
A) Fugitive Emissions
Fugitive emissions in cement plant is due to various process and non-process related activities which
are given below:
Process related activities
Material Handling and Transfer
o Loading and unloading operation of raw material and finished product
o Transfer operations (Transfer Points)
o Silos Vent
Milling Operations
o Primary and Secondary crushing of limestone, coal and petcoke
o Grinding of clinker, fly ash and gypsum
Non-process related activities
Vehicular Traffic
o Movement of raw material and finished product by trucks / trailer from main gate to
designated place inside the plant and vice-versa
o Movement of personnel vehicles
Material Storage
o Material (e.g. limestone) stored in open yard
Adequate pollution control measures have been / will be taken to keep the fugitive emissions from all
sources within the statutory norms, brief of which are given below:
Limestone is being / will be transported to cement plant from crusher via covered conveyor
belt.
A set of water spray nozzles is being / will be provided over the conveyor belt in the stacker
feed point.
Bag filters is being / will be installed at all material transfer points.
Sprinkling of water on roads is being / will be done.
Regular cleaning and sweeping of roads, near-by area of storage yard etc. is being / will be
done.
Details on fugitive emission control measures is given in Chapter - X of this EIA/EMP Report.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 122 JM EnviroNet Pvt. Ltd.
B) Stack Emissions
In a cement plant, the major emission from stack is Particulate Matter (PM) emissions. In addition,
gaseous pollutants (SO2, NOx and CO) are also anticipated from stack emissions andvehicular
emissions.
Efficient Air Pollution Control Equipment (APCE) like Bag House / Bag Filter / ESP is being / will be
installed at all major stacks to keep the emissions within the permissible limits.
Pyro-process itself acts as a long SO2 scrubber. Kiln with pre heater /Calciner removes 70-95% SO2
emissions. Installation of a good burner system will provide improved combustion efficiency of
the fuel and also avoid flame impingement on the raw materials.
NOx generation takes place at high temperature and excess air. Low NOx burner is being / will be
installed for fuel burning along with calciner for low NOx formation.
Vehicles and machineries is being / will be regularly maintained. Proper upkeep and maintenance of
vehicles is being / will be done.
Hence, the overall quality of the ambient air will be maintained within the limit prescribed by
CPCB/SPCB after the commencement of the operation of proposed expansion project.
4.4.2.2 Air Quality Predictions through Mathematical Modeling
The present study assesses the impact on air environment due to Expansion of Integrated Cement
Project - Clinker (10.4 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW),
CPP (180 MW) along with Synthetic Gypsum Unit (1560 TPD) and DG Sets (1000 to 2000 KVA) near
Village: Ras, Tehsil: Jaitaran, District: Pali, Rajasthan by M/s. Shree Cement Ltd. (SCL).
This report gives the peak incremental ground level concentrations of PM, SO2 and NOx up to a
distance of 10 km radius from the plant site and also the cumulative peak incremental
concentrations of PM10 due to proposed expansion activities of plant and captive mine of SCL.
The concentrations have been predicted in all directions covering all types of weather conditions.
Spatial distributions of all the pollutants are also presented in the form of Isopleths.
4.4.2.2.1 Air Pollution Modeling
Prediction of impacts on air environment has been carried out employing mathematical model
based on a steady state Gaussian plume dispersion model designed for multiple point sources for
short term. In the present case, AERMOD version 8.1 dispersion model based on steady state
gaussian plume dispersion, designed for multiple point sources and developed by United States
Environmental Protection Agency [USEPA] has been used for simulations from Industrial sources.
4.4.2.2.2 Pollutants/Model Options Considered for Computations
The model simulations deal with major pollutant Particulate Matter (PM), SO2 and NOx emitted
from the proposed expansion project of cement plant. Particulate matter (PM) pollutants in case
of limestone mining activity have been only considered and there is no major fuel combustion
during the mining activity. Hence, gaseous emission has not been considered for mining activity.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 123 JM EnviroNet Pvt. Ltd.
4.4.2.2.3 Model Options Used for Computations
The options used for short-term computations in AEROMOD are:
The plume rise is estimated by Briggs formulae, but the final rise is always limited to that of
the mixing layer;
Stack tip down-wash is not considered;
Buoyancy Induced Dispersion is used to describe the increase in plume dispersion during
the ascension phase;
Calms processing routine is used by default;
Wind profile exponents is used by default, 'Irwin';
Flat terrain is used for computations;
It is assumed that the pollutants do not undergo any physio-chemical transformation and
that there is no pollutant removal by dry deposition;
Washout by rain is not considered;
Cartesian co-ordinate system has been used for computations; and
The model computations have been done for total 20 km with 500-m interval.
4.4.2.2.4 Model Input Data
a) Meteorological Data
Meteorological inputs required are Temperature, Relative Humidity, Wind Speed and Wind
Direction etc. which was recorded at site during Summer Season (March to May, 2015).Hourly
Meteorological Data has been enclosed as Annexure -4 with this Final EIA / EMP Report.
b) Stack Emission Data
The emission details are given in Tables - 4.1.
Table - 4.1
Stack Emission Details
S.No.
Stack attached to
Heightfrom
groundlevel (m)
InternalDiameter
(Top)
(m)
Emission Rate (kg/hr) ExitVelocity(m/sec)
Exhaust Gas
Temp.(oC)
Density
(kg/Nm3)
Specific
Heat(kj/kgoC)
Volumetric
Flow
(m3/hr)PM SO2 NO2
1. Raw Mill & Kiln - IX 150 5 23.53 146.61 627.37 32.89 240 1.4 1.045 1350000
2. Coal Mill - IX 63 2 4.21 NA NA 21.58 120 1.35 1.045 185000
3. Clinker Cooler - IX 60 4.3 13.05 NA NA 28.15 275 1.29 0.878 800000
4. Raw Mill & Kiln - X 150 5 23.53 146.61 627.37 34.82 240 1.4 1.045 1350000
5. Coal Mill - X 63 2 4.21 NA NA 21.58 120 1.35 1.045 185000
6. Clinker Cooler - X 60 4.3 13.05 NA NA 28.15 275 1.29 0.878 800000
7. Raw Mill & Kiln - 11 150 5 23.53 146.61 470.53 34.82 240 1.4 1.045 1350000
8. Coal Mill - 11 63 2 4.21 NA NA 21.58 120 1.4 1.045 185000
9. Clinker Cooler - 11 60 4.3 13.05 NA NA 28.15 275 1.29 0.878 800000
10. Cement Mill VRM 50 4 11.72 NA NA 36.67 93 1.29 0.878 480000
11.Cement Mill - BallMill
27 1.63 1.60 NA NA 30.01 90 1.29 0.878 65000
12.Ball Mill withSynthetic Gypsum
27 1.63 1.60 NA NA 30.01 90 1.29 0.878 65000
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 124 JM EnviroNet Pvt. Ltd.
c) Area Emission Source
The emissions from the proposed captive mine have been computed using empirical factor given
in Indian Mining and Engineering Journal . The details of emission computed from mining
operations are given below:
Existing Limestone Mine (ML Area: 750 ha)
Total Limestone Handling in the mine is 79062.5 TPD on the basis of 320 working days per annum.
Per hour handling of limestone (on the bases of 24 hr/day operation or three shifts) is 3294.2 t/ hr.
Total OB Handling in the mine is 34954 TPD on the basis of 320 working days per annum. Per hour
handling of OB (on the basis of 24 hr/day operation) is 1456 t/ hr.
Total handling of material will be 4750.61 t/ hr.
Rate of emission being 23.6 kg/ hr for handling 1000 ton the emission rate shall be
= 4750.61 X 23.6 = 112.11 kg/hr or 31.14 gm/ sec
1000
The above mentioned emission rates are uncontrolled emissions. Due to installation and operation
of dust control measures at mining site, the emissions will be one third of established emissions.
This is based on experience and literature. Accordingly, rates considered, in the mathematical
modelling is equal to 10.38 gm/sec (31.14/3).
The emission rates and conditions have been summarized in Table below.
Table - 4.2
Emission Rate and Emission Conditions
1. Mine Area
Total Limestone Handling
=
=
750 ha
25.3 MTPA
2. Dust Emission Rate
(i) Uncontrolled
(ii) Controlled
31.14 gm/s
10.38 gm/s
Emission Temperature = Ambient
4.4.2.2.5 Modeling Procedure
Prediction of ground level concentrations (GLC s) due to proposed expansion of Cement plant has
been made by AERMOD version 8.1 as per CPCB guidelines. It is US-EPA approved model to predict
the air quality. The model uses rural dispersion and regulatory defaults options as per guidelines on air
quality models (PROBES/70/1997-1998). For this study, uniform polar receptors on flat terrain have
been assumed.
Meteorological inputs required are hourly wind speed and direction, ambient temperature, stability
class, and mixing height. The model details are as follows:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 125 JM EnviroNet Pvt. Ltd.
4.4.2.2.6Gaussian Plume Model
The AERMOD version 8.1 model is based on a numerical integration over the area in the upwind and
cross wind directions of Gaussian plume formula. This can be applied to the Point, Area, Line, Volume
sources (and other forms of area sources) simultaneously and their resultant incremental
concentration of the pollutant can be predicted.
4.4.2.2.7 Extrapolation of Wind Speed
Wind speed at stack level is calculated by power law as given below.
Ustack = U10(Stack height/10) p
Where U10 is the wind speed at 10 meter level and p is the power law coefficient (0.07, 0.07, 0.10, 0.15,
0.35 and 0.55 for stability classes A,B,C,D,E and F respectively) as per Irwin for rural areas (USEPA,
1987).
4.4.2.2.8 Stability Classification
Hourly stability is determined by wind direction fluctuation method as suggested by Slade (1965) and
recommended by CPCB (PROBES/70/1997-1998).
a = Wdr/6
a, is standard deviation of wind direction fluctuation, Wdr is the overall wind direction fluctuation or
width of the wind direction in degrees. The table for stability classes is given as under:
Stability Class σa (degree)
A > 22.5
B 22.4 17.5
C 17.4 12.5
D 12.4 7.5
E 7.4 3.5
F < 3.5
4.4.2.2.9 Dispersion Parameters
Dispersion parameters y and z for open country conditions (Briggs, 1974) are used as the project is
located on a flat terrain in a rural area. Atmospheric dispersion coefficients vary with downwind
distance (x) from emission sources for different atmospheric stability conditions. (CPCB
PROBES/70/1997-98).
Rural Conditions
Stability Class σy σaz
A 0.22x(1+0.0001x)-.5 0.20x
B 0.16x(1+0.0001x)-.5 0.12x
C 0.11x(1+0.0001x)-.5 0.08x(1+0.0002x).5
D 0.08x(1+0.0001x)-.5 0.06(1+0.0015x).5
E 0.06x(1+0.0001x)-.5 0.03x(1+0.0003x)-1
F 0.04x(1+0.0001x)-.5 0.16x(1+0.0003x)-1
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 126 JM EnviroNet Pvt. Ltd.
4.4.2.2.10 Mixing Height
As site specific mixing heights were not available, mixing heights based on IMD publication, Atlas of
Hourly Mixing Height and Assimilative Capacity of Atmosphere in India , has been considered for
Industrial Source Complex model to establish the worst case scenario.
Table - 4.3
Mixing Height for the Plant Site - Summer Season
Time (Hours) Mixing Height (m)
0600 110
0700 100
0800 175
0900 350
1000 875
1100 900
1200 1500
1300 1800
1400 2350
1500 2550
1600 2350
1700 2225
1800 2200
1900 1750
2000 1525
Source: IMD publication, Atlas of Hourly Mixing Height and Assimilative Capacity of Atmosphere in India
4.4.2.2.11 Presentation of Results
In the present case, model simulations have been carried using the hourly Triple Joint Frequency data.
Short-term simulations were carried to estimate concentrations at the receptors to obtain an
optimum description of variations in concentrations over the site in 10 km radius covering 16
directions.
The incremental concentrations are estimated for the monitoring period. For each time scale, i.e. for
24 hr the model computes the highest concentrations observed during the period over all the
measurement points.
Existing value has been covered in the Background Ambient Air Quality Monitoring.
Table - 4.4
Peak Incremental Concentration for Different Scenarios
ScenariosIncremental Concentration of Pollutants, µg/m3
PM SO2 NO2
Cement Plant Expansion only 3.22 1.32 4.30
Mine only 4.86 - -
Cement Plant and Mine - Cumulative Impact 4.98 1.32 4.30
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 127 JM EnviroNet Pvt. Ltd.
For Particulate Matter, maximum GLC for Cement Plant expansion is found to be 3.22 µg/m3 50m away
from the plant boundary (Figure 4.1). For Mine expansion project, maximum GLC for PM is found to
be 4.86µg/m3 400m away from mine pit within mine lease boundary. Maximum GLC for PM for
cumulative impact have been found to be 4.96 µg/m3 along plant boundary 400m away from stack
location towards NE direction (Figure 4.4).
Gaseous emission will be mainly due to cement plant expansion only, and mining activity will have no
significant impact on the gaseous emission as explained above. Maximum GLC for SO2 is found to be
1.32 µg/m3900m away from the plant boundary in NE direction. Contours for the incremental SO2
concentrations on the mining area are shown due to the plant activity itself (Figure 4.2).
Maximum GLC for NO2 is found to be 4.30 µg/m3 at NE plant boundary, 900m away from the stack
location. Contours for the incremental NO2 concentrations on the mining area are shown due to the
plant activity itself (Figure 4.3).
The maximum incremental GLCs due to the proposed expansion of cement plant and proposed mine
for PMare superimposed on the maximum baseline PM concentrations recorded at the monitoring
locations during the field monitoring period. The maximum GLCs after implementation of the
proposed expansion project are very much likely to be within the prescribed NAAQ standards.
There will be no significant threat to the gaseous pollutants of the ambient air quality; however,
concentration of particulate matter is a subject of concern - though not immediate. Proper mitigation
plan for dust control has to be implemented in both the plant premises and mining lease area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 128 JM EnviroNet Pvt. Ltd.
Figure 4.1: Isopleth showing the incremental GLCs of PM10 due to Plant activities
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 129 JM EnviroNet Pvt. Ltd.
Figure 4.2: Isopleth showing the incremental GLCs of SO2due to Plant activity
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 130 JM EnviroNet Pvt. Ltd.
Figure 4.3: Isopleth showing the incremental GLCs of NO2 due to Plant activities
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 131 JM EnviroNet Pvt. Ltd.
Figure 4.4: Isopleth showing the incremental GLCs of PM due to Plant and Mining activities
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 132 JM EnviroNet Pvt. Ltd.
4.4.2.3 Impact due to Transportation of Raw Material and Finished Product
Shree Cement Plant at Pali is well connected with NH - 14 (~ 19.5 Km in SE direction) and SH - 39
(~1.5 Km in NE direction). Nearest Railway Station is Beawar Railway Station which is about 21 km
in SE direction from the plant site. Nearest Airport is at Jodhpur which is approx. 113 km in West
direction from the plant site.
Major raw material used for manufacturing of cement i.e. Limestone is being / will be transported
by covered conveyor belt; thus, there is being / will be no impact due to transportation of the
same.
Fly ash is being / will be transported through closed bulkers; thus, no harmful effect is anticipated
on the surrounding environment due to transportation of fly ash.
Existing Traffic Survey
Traffic survey has been conducted for 24 hours at SH - 39 (Beawar to Ras Road). This approach
road connects the plant site to NH - 14; which is approx. 19.4 Km in SE direction from the plant site.
The traffic survey monitoring was done in June, 2015 to predict the future traffic growth and the
load on the plant road and surroundings due to the proposed expansion project.
Measurements of Traffic density were made continuously for 24 hours by visual observation and
counting of vehicles under four categories, viz., heavy motor vehicles, light motor vehicles,
two/four wheelers and others. Total numbers of vehicles per hour under the four categories were
determined. The details of the traffic volume count have been provided in Table 4.5 given below:
Table - 4.5
Traffic Volume Count Survey
S. No. TimeType of vehicle
Heavy Vehicle Four wheeler Two wheeler Others Total vehicle
1. 6:00 to 7:00 am 48 18 57 74 197
2. 7:00 to 8:00 am 44 16 48 84 192
3. 8:00 to 9:00 am 39 22 42 64 167
4. 9:00 to 10:00 am 49 27 49 63 188
5. 10:00 to 11:00 am 52 31 43 108 234
6. 11:00 to 12 noon 59 28 53 97 237
7. 12:00 to 1:00 pm 61 24 29 69 183
8. 1:00 to 2:00 pm 64 18 53 72 207
9. 2:00 to 3:00 pm 68 46 42 81 237
10. 3:00 to 4:00 pm 67 45 46 67 225
11. 4:00 to 5:00 pm 69 28 50 77 224
12. 5:00 to 6:00 pm 68 19 43 134 264
13. 6:00 to 7:00 pm 63 24 29 118 234
14. 7:00 to 8:00 pm 68 32 34 113 247
15. 8:00 to 9:00 pm 63 25 42 89 219
16. 9:00 to 10:00 pm 62 22 33 68 185
17. 10:00 to 11:00 pm 69 9 23 43 144
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 133 JM EnviroNet Pvt. Ltd.
S. No. TimeType of vehicle
Heavy Vehicle Four wheeler Two wheeler Others Total vehicle
18. 11:00 to 12:00 pm 69 12 13 9 103
19. 12:00 to 1:00 am 74 0 9 3 86
20. 1:00 to 2:00 am 86 4 2 0 92
21. 2:00 to 3:00 am 84 3 6 9 102
22. 3:00 to 4:00 am 68 0 10 14 92
23. 4:00 to 5:00 am 69 9 18 68 164
24. 5:00 to 6:00 am 77 13 27 87 204
Grand Total 1540 475 801 1611 4427
Figure 4.5: Traffic Volume Count
Conclusion
From the study, it was observed that Traffic movement in the 10 Km radius of the study area is
busy. At present, the traffic load calculated at Beawar to Ras Road connecting plant site to SH - 39
is approximately 4427 vehicles per day. The study area is served by road transport. Most of the
villages are connected by bus / other transport services. The area has a moderate road network,
which includes National highway, Major District Roads and other roads.
Figure 4.5 clearly shows that Heavy vehicles (34.78%) runs mainly on Beawar to Ras Road followed
by Two wheeler (18.09%) and four wheelers (10.7%). Majority of the total traffic comprises of
others (36.39%), which includes three wheelers, tractors, animal drawn vehicles etc.
Additional Traffic due to Proposed Expansion Project
Both raw and finished materials will be transported by road as well as rail. Due to proposed
expansion project, there will be additional trucks to the existing traffic volume. Adequate parking
facilities will be provided to accommodate additional trucks within the plant premises.
Additional Traffic during operation of the plant due to raw material and finished products
transportation has been given in Table - 4.6(A) and 4.6 (B).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 133 JM EnviroNet Pvt. Ltd.
S. No. TimeType of vehicle
Heavy Vehicle Four wheeler Two wheeler Others Total vehicle
18. 11:00 to 12:00 pm 69 12 13 9 103
19. 12:00 to 1:00 am 74 0 9 3 86
20. 1:00 to 2:00 am 86 4 2 0 92
21. 2:00 to 3:00 am 84 3 6 9 102
22. 3:00 to 4:00 am 68 0 10 14 92
23. 4:00 to 5:00 am 69 9 18 68 164
24. 5:00 to 6:00 am 77 13 27 87 204
Grand Total 1540 475 801 1611 4427
Figure 4.5: Traffic Volume Count
Conclusion
From the study, it was observed that Traffic movement in the 10 Km radius of the study area is
busy. At present, the traffic load calculated at Beawar to Ras Road connecting plant site to SH - 39
is approximately 4427 vehicles per day. The study area is served by road transport. Most of the
villages are connected by bus / other transport services. The area has a moderate road network,
which includes National highway, Major District Roads and other roads.
Figure 4.5 clearly shows that Heavy vehicles (34.78%) runs mainly on Beawar to Ras Road followed
by Two wheeler (18.09%) and four wheelers (10.7%). Majority of the total traffic comprises of
others (36.39%), which includes three wheelers, tractors, animal drawn vehicles etc.
Additional Traffic due to Proposed Expansion Project
Both raw and finished materials will be transported by road as well as rail. Due to proposed
expansion project, there will be additional trucks to the existing traffic volume. Adequate parking
facilities will be provided to accommodate additional trucks within the plant premises.
Additional Traffic during operation of the plant due to raw material and finished products
transportation has been given in Table - 4.6(A) and 4.6 (B).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 133 JM EnviroNet Pvt. Ltd.
S. No. TimeType of vehicle
Heavy Vehicle Four wheeler Two wheeler Others Total vehicle
18. 11:00 to 12:00 pm 69 12 13 9 103
19. 12:00 to 1:00 am 74 0 9 3 86
20. 1:00 to 2:00 am 86 4 2 0 92
21. 2:00 to 3:00 am 84 3 6 9 102
22. 3:00 to 4:00 am 68 0 10 14 92
23. 4:00 to 5:00 am 69 9 18 68 164
24. 5:00 to 6:00 am 77 13 27 87 204
Grand Total 1540 475 801 1611 4427
Figure 4.5: Traffic Volume Count
Conclusion
From the study, it was observed that Traffic movement in the 10 Km radius of the study area is
busy. At present, the traffic load calculated at Beawar to Ras Road connecting plant site to SH - 39
is approximately 4427 vehicles per day. The study area is served by road transport. Most of the
villages are connected by bus / other transport services. The area has a moderate road network,
which includes National highway, Major District Roads and other roads.
Figure 4.5 clearly shows that Heavy vehicles (34.78%) runs mainly on Beawar to Ras Road followed
by Two wheeler (18.09%) and four wheelers (10.7%). Majority of the total traffic comprises of
others (36.39%), which includes three wheelers, tractors, animal drawn vehicles etc.
Additional Traffic due to Proposed Expansion Project
Both raw and finished materials will be transported by road as well as rail. Due to proposed
expansion project, there will be additional trucks to the existing traffic volume. Adequate parking
facilities will be provided to accommodate additional trucks within the plant premises.
Additional Traffic during operation of the plant due to raw material and finished products
transportation has been given in Table - 4.6(A) and 4.6 (B).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 134 JM EnviroNet Pvt. Ltd.
Table - 4.6 (A)
Inward Traffic due to the Raw Material Transportation*
Material Source / Origin DestinationType of vehicle and
Capacity
Number of Trips / Day (approx.)
Existing Additional
Laterite Bhilwara
Truck / 30 Tonnes 51 17Lead Zinc Slag
Chhitorgarh (Raj) and other nearby
sources.
Gypsum
(Mineral, Synthetic,
Chemical and
Imported)
Bikaner, Nagaur (Raj), SCL Units,
Gujarat, other sources and Other
countries
Truck / 30 Tonnes 44 22
Conc. Sulphuric acid Local market Tanker / 29 Tonnes 29 -
Fly Ash
STPS, Suratgarh; KTPS Kota; Chabra
and other power plants and other
nearby sources
Bulker / 30 Tonnes 303 151
Petcoke / Coal / lignite
Reliance, IOCL, Essar and other
Petrochemical Refineries, USA,
Swiss, Saudi Arabia, Rajasthan etc.
Truck / 30 Tonnes 440 115
TOTAL 867 305
*Considering 100% by Road to Calculate Maximum Pollution Load
Table - 4.6 (B)
Outward Traffic due to the Finished Product Transportation
Material Source / Origin DestinationType of vehicle and
Capacity
Number of Trips/ day (approx.)
Existing Additional
Clinker SCL, Balodadabazar - Bhatapara Truck / 30 Tonnes 517 198
Cement SCL, Balodadabazar - Bhatapara Truck / 30 Tonnes 889 444
TOTAL 1406 642
Traffic Projection and Impact due to Transportation
Due to the proposed expansion project, there will be addition of Heavy and Light motor vehicles
in the existing traffic.
The present road network is good enough to bear the increased traffic load. However, internal
and nearby roads will be maintained as and when needed to facilitate transportation.
Railway siding with loading / unloading facilities at Shree Cement Ltd. - Alternative option for
transportation
A railway siding connects the plant to Beawer Railway Station, which is about 21 km in SE direction
from the plant site. Emissions per ton - km of road transport are higher than emission per ton - km
caused by rail transport. Thus, SCL will achieve emission reductions by using rail as mode of
transport for clinker and cement.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 135 JM EnviroNet Pvt. Ltd.
Details of the raw material and finished products transportation by rail have been given in Table -
4.6 (C) and 4.6 (D).
Table - 4.6 (C)
Inward Traffic: Railways - Raw Material
MaterialNo. of Wagon and
Capacity
Number of Trips / day (approx.)
Existing Additional
Laterite / Lead Zinc Slag 60 / 55 Tonnes 0.460.16 (One train with 60 numbers
wagon in five days)
Gypsum (Mineral, Synthetic,
Chemical and Imported)60 / 55 Tonnes 0.40
0.2 (One train with 60 numbers
wagon in three days)
Petcoke/Coal/ Lignite 60 / 55 Tonnes 4 1
Table - 4.6 (D)
Outward Traffic: Railways - Finished Products
MaterialNo. of Wagon and
Capacity
Number of Trips / day (approx.)
Existing Additional
Clinker 60 / 55 Tonnes 5 2
Cement 60 / 55 Tonnes 8 4
Thus, the environmental impact is considered to be positive based on reduced air pollution
basically of particulate matter as emitted by diesel trucks. Overall fossil fuel consumption will be
reduced, resulting reduction of emissions of the release of CO2 and CH4, NOx etc.
SCL will take all appropriate measures to reduce the impact of transportation. Proper mitigation
measures will be adopted by SCL to minimize traffic flow to the best possible extent resulting in
low level of dust, noise and gaseous emissions.
Anticipated Impacts
Increase in traffic density will lead to air pollution.
Movement of vehicles will cause noise pollution.
No direct impact is envisaged on the flora and fauna of the area.
Increased traffic may cause accidental incidences and public health problems.
Mitigation Measures
Vehicles with PUC Certificate will be hired.
Vehicles will be covered with a tarpaulin and not over loaded.
Un- necessary blowing of horn will be avoided.
Roads will be maintained in good condition to reduce noise due to traffic.
Greenbelt of appropriate quality and width will be developed.
To avoid accidents, the speed of vehicles will be low near habitation areas.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 136 JM EnviroNet Pvt. Ltd.
4.4.3 Impact on Noise Level and Mitigation Measures
During operation phase, noise is being / will be generated due to following activities / processes:
Operation of plant machineries viz. kiln, exhaust fans, grinding mills, crushers, compressors,
pumps and motors etc. It may be due to poor lubrication, worn out parts, loosened nuts/
bolts, improper foundation and its mountings, flattened springs support etc.
Movement of vehicles and other ancillary activities
With increasing distance from the source, the noise level decreases due to wave divergence.
Additional decrease also occurs due to atmospheric effects and interaction with objects in the
transmission paths. Following noise abatement measures is being / will be taken:
Persons working just close to machine and machine operators is being / will be provided
with personal protective equipment viz. Ear plugs / Ear muffs etc.
Proper maintenance, oiling and greasing of machines at regular intervals is being / will be
done to reduce generation of noise
Greenbelt of appropriate width at the plant boundary is being developed
Regular monitoring of noise level is being / will be carried out and corrective measures in
concerned machinery is being / will be adopted accordingly to the possible extent
4.4.4 Impact on Water Quality and Mitigation Measures
The water requirement for existing Integrated Cement Plant is 2800 m3/day. Additional 700 will be
required for the proposed expansion project; hence, the total water requirement after the
proposed expansion project will be 3500 m3/day; which will be sourced from Ground water.
Permission for withdrawal of ground water has already been obtained from CGWA.
No waste water is likely to be generated during cement manufacturing process. No waste water
will be discharged outside the plant premises. Therefore, operation of proposed expansion of
Cement Plant will not pose any adverse impact on the ground water resources of the area.
Domestic wastewater generated from plant and colony is being / will be treated in STP and
treated water is being / will be utilized for greenbelt development / plantation. RO reject water is
being / will be used in Synthetic Gypsum manufacturing process, ash quenching and dust
suppression. Rain water harvesting is being practiced inside the plant and colony premises.
Regular monitoring of water quality is being / will be carried out. Training and awareness
programmes on water conservation measures will also be organized for the locals.
4.4.5 Impact on Soil and Mitigation Measures
The soil of the area may get affected due to operational activities, if proper care is not taken.
i) Changes in soil texture due to settling of air borne dust or due to wash off of solid
particulates by surface or ground water. This will lead to change in porosity, permeability
and other physical characteristics of soil of the area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 137 JM EnviroNet Pvt. Ltd.
ii) Changes in soil chemistry due to addition of foreign material from polluted air and water
due to unit activities in the area.
Efficient Air Pollution Control Equipment (APCE) like Bag House / Bag Filter / ESP is being / will be
installed at all major stacks of cement plant to keep the emissions within 30 mg/Nm3. Adequate stack
height helps to control dust emissions. No waste water will be discharged outside the plant
premises. A horticulturist has been engaged who ensures soil quality improvement in the plant
area, by adequate manuring and fertilizing. Therefore, no adverse impact on the soil quality of the
area is anticipated.
Besides, soil samples are being collected and tested at regular intervals from the nearby areas.
This helps in mitigation of any harmful impact on soil due to the project expansion activity, if any,
and the same will be practiced after proposed expansion also.
4.4.6 Impact due to Solid and Hazardous Waste Generation
No solid waste is being / will be generated from the cement manufacturing process. Dust collected
from air pollution control equipment is being / will be totally recycled in process. Sludge from
Sewage Treatment Plant (STP) is being / will be used as manure for greenbelt development /
plantation. Fly ash generated from captive power plant is being / will be utilized in cement
manufacturing process.
No hazardous waste is being / will be generated except the used oil which is being / will be
collected in drums, temporarily stored at earmarked place and is being / will be sold to the
authorized CPCB recyclers.
4.4.7 Impact on Biological Environment
There are no direct or indirect evidence of presence of any major wildlife in the core and buffer
areas of the project. There is no National Park, Wildlife Sanctuary, Biosphere Reserves (existing as
well as proposed) in the study area; there is only one Reserve Forest and one Protected Forest
within 10 km of the plant area. No Schedule- I species were recorded in the core and buffer zone
of plant area during the biological survey.
There may be an impact on the biological environment of the area due to operation of cement
plant, if proper care will not be taken:
i) Particulate matter emissions from stack and fugitive emissions due to transportation
activity & material handling may degrade the soil quality of surrounding environment that
may affect the biodiversity of surrounding environment.
Particulate matter emission may cause migration of wild animals and bird.
Fugitive emissions (dust) may impact the terrestrial flora. The settlement of dust on the
laminar surface of plants can impede the efficiency of photo-transduction and thereby,
affect the productivity of plants. In some of the plant, it may also smother the leaf surface
blocking stomata, resulting in reduced transpiration.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 138 JM EnviroNet Pvt. Ltd.
ii) Increased noise level due to running of machinery may scare the wild fauna and force them
to migrate to other areas.
The present running plant has no significant impact on surrounding ecology and biodiversity as
following mitigative measures have been / will be adopted by SCL:
Scaling up the greenbelt development and plantation in and around the Plant site.
Use of water sprinkler on the haul road to control fugitive emissions in the surrounding
environment.
Using paved roads for transportation to minimize fugitive emissions.
Transporting material in close truck and storing it under tarpaulin cover.
Transport vehicles and machinery will be properly maintained and periodically checked for
pollution level to reduce noise and gaseous emission in the surrounding environment.
4.4.8 Impact on Socio-Economic Environment
Project potential impacts on socio-economic environment are summarized below and categorized
either as positive / beneficial or negative / adverse impacts.
Positive impacts
Employment
Employment opportunities will be created by M/s. Shree Cement Ltd. during planning and
preparation, construction and operational phases of the proposed expansion project and it
will provide a sustainable and safe working environment for workers.
Community Skills Development
The employees will be benefited from the training programmes that are instituted by SCL to
enable the community labour force to work in different areas of production.
Improved Standards of Living
Employment opportunities created by the project will increase income and therefore
improve the overall standards of living in the area.
Community Organizational Capacity Development
Through engagement of community members in development structures such as
Community Development Committees, the community organizational capacity will be
developed.
Improved Water Supply
Supply of safe water for the community by M/s. Shree Cement Ltd. will improve health
standards and living conditions in the villages.
Economic Exposure and Development
Implementation of the project will make financial institutions as well as related economic
facilities, infrastructure and services available to the people. This will expose and introduce
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 139 JM EnviroNet Pvt. Ltd.
the local population to factors of economic development including the banking system,
financial services, and credit and investment schemes.
In order to maximize the project s positive impacts during the construction phase, it is
proposed that local and national workers be used as much as possible and also, whenever
possible, local companies to supply the construction materials, therefore stimulating the
job market and the local economic activities.
Adverse Social Impacts
Health Impacts
The project has the potential for triggering health impacts through air pollutants from
heavy vehicles, increased dust, creation of breeding grounds for disease vectors, population
influx which might introduce new diseases in the area, and inadequate sanitation facilities.
Livelihood change
Due to the labour intensity of the manufacturing sector, the project will attract the more
able-bodied persons from the community which in turn will lead to low labor availability in
other sectors of the economy including agricultural, education and health skilled workers.
Local employment opportunities will be created by the project. This impact will not be
significant due to low level of education and skills in the area which will result in sourcing
skilled workforce from outside the immediate area. But the magnitude of this impact will
be high due to high number of dependents in a household.
Mitigation Measures
Mitigating Health Impacts
An awareness programme on health hazards can be implemented to safeguard the
employees as well as the local population s health. M/s. Shree Cement Ltd. should have a
clinic for its employees and also provide assistance, in conjunction with government and
NGOs, to the medical service for the villages. This way, the health issues can be monitored
and addressed.
Managing Loss of Livelihood and Income
To cushion the population against impacts of manufacturing unit closure, comprehensive
retrenchment packages that include adequate advance warning to employees and
contractors to allow them to source alternative opportunities should be undertaken.
4.4.9 Impact on Occupational Health and Mitigation Measures
The cement manufacturing industry is labour intensive and uses large scale and potentially
hazardous manufacturing processes. The industry experiences accident rates that are high
compared with some other manufacturing industries. Cement industries experience risk of a
number of hazards inherent to the cement production process. Some examples of such hazards
are:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 140 JM EnviroNet Pvt. Ltd.
Exposure to dust,
Exposure to high temperatures,
Noise exposure,
Physical hazards,
Chemical hazards and other industrial hygiene issues, and
Others
These mainly impact on those working within the industry, although health hazards can also
impact on local communities.
Exposure to Dust
Exposure to fine particulates is associated with work in most of the dust-generating stages of
Cement Plant, but most notably from, raw material handling, and clinker / cement grinding.
Workers with long term exposure to fine particulate dust are at risk of pneumoconiosis,
emphysema, bronchitis, and fibrosis.
Methods to prevent and control exposure to dust include the following:
Control of dust through implementation of good housekeeping and maintenance;
Use of air conditioned, closed cabins;
Use of dust extraction and recycling systems to remove dust from work areas, especially in
grinding mills;
Use of PPE, as appropriate (e.g. masks and respirators) to address residual exposures
following adoption of the above-referenced process and engineering controls.
Exposure to High Temperatures
The principal exposures to heat in this sector occur during Handling of hot raw meal (Powdered
limestone, additives etc. is heated in a pre-heater cyclone), hot clinker and operation &
maintenance of kilns or other hot equipment. Recommended prevention and control techniques
include the following:
Shielding surfaces where workers proximity and close contact with hot equipment is
expected, using Personal Protective Equipment (PPE), as needed (e.g. insulated gloves and
shoes);
Minimizing the work time required in high temperature environments by implementing
shorter shifts at these locations.
Noise and Vibration Exposure
Exhaust fans and grinding mills, kiln, compressors, and motors are the main sources of noise and
vibrations in Cement Plant. Control of noise emissions will include the use of silencers for ID fans,
room enclosures for mill operators, noise barriers, and, if noise cannot be reduced to acceptable
levels, personal hearing protection (ear plugs/muffs).
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 141 JM EnviroNet Pvt. Ltd.
Physical hazards
Injuries during Project operation are typically related to slips, trips, and falls; contact with falling /
moving objects; and lifting / over-exertion.
Other injuries may occur due to contact with, or capture in, moving machinery (e.g. dump trucks,
front loaders, forklifts). Activities related to maintenance of equipments, including crushers, mills,
mill separators, fans, coolers, and belt conveyors, represent a significant source of exposure to
physical hazards. Such hazards may include the following:
Falling / impact with objects;
Hot surface burns; and
Transportation
Contact with allergic substances.
Following management measures will be ensured to prevent the physical hazards in the plant:
Any person working on equipment with moving parts personally ensures the equipment is
de-energized, isolated and locked/tagged out.
Any person working from a position with the potential risk for a fall from height uses fall
protection.
Prescribed PPE has been provided to all workers exposed to open processes or systems.
In case of any accident immediate & proper medical care is being provided at the plant site.
High Risk Categories: Prevention:
Contractors Contractor Safety Management
Young/Temporary Employees Special Safety Induction
Direct Causes
Traffic and Mobile Plant Driver Training
Falls from Heights, Objects falling from Heights Safety Procedures for Work at Heights,
Overhead Protection
Caught in Starting/Moving Equipment Plant Isolation Procedures
4.5 SUMMARY AND CONCLUSION
The environmental impact evaluation of possible effects as a result of plant site activities and
operation on various environmental parameters is primarily based on careful study of Cement
Plant, Unit operations, surrounding environment etc. For various proposed expansion project
activities, effective Control Technology has been suggested with a view to mitigate the adverse
impact of unit operation on environmental parameters. The summary of anticipated adverse
environmental impacts and mitigation measures are given in Table - 4.7.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 142 JM EnviroNet Pvt. Ltd.
Table - 4.7
Anticipated Adverse Environmental Impacts and Mitigation
Discipline Anticipated Impact Mitigation Measures
Construction Phase
Air Increase in dust and NOx concentration
due to Leveling activity and Heavy
vehicular movement
Sprinkling of water in the construction area and on
unpaved roads
Proper maintenance of vehicles will be done. Use of
vehicles meeting PUC norms
Noise Increase in noise level due to
Construction Equipment
Equipment will be kept in good condition to keep
the noise level within 90 dB(A)
Workers will be provided necessary protective
equipments e.g. ear plugs, earmuffs
Water Increase in suspended solids due to soil
run-off during heavy precipitation due to
Loose soil at construction site
Adequate drainage system for runoff water during
construction phase
Operation Phase
Air Increase in concentration of Particulate
Matter Emissions
Better maintenance and installation of pollution
control equipment like ESP / Bag House / Bag Filters
Covered storage facilities for raw material and
product
All the roads inside the plant premises will be
concreted
Water sprinkling to reduce the PM emission level
CPCB and CREP guidelines are being / will be
followed
Increase in NO2 emissions Low NO2 burners
Noise Increase in noise level within the plant
area
Equipment to be installed is designed to conform to
occupational noise levels prescribed by regulatory
agencies
Earmuffs/ Earplugs will be provided to persons
working in high noise zone
Properly insulated enclosures will be provided to
equipments making excessive noise
Greenbelt development/ plantation will help in
attenuating noise
Water Generation of waste water Domestic wastewater generated from plant and
colony is being / will be treated in STP and treated
water is being / will be utilized for greenbelt
development / plantation
RO reject water is being / will be used in Synthetic
Gypsum manufacturing process, ash quenching and
dust suppression.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IV of Final EIA / EMP Report
M/s. Shree Cement Ltd. 143 JM EnviroNet Pvt. Ltd.
Soil Degradation of soil quality due to
settling of air borne dust
Use of efficient pollution control systems
Maintained proper stack height
Soil samples are being/ will be collected periodically
and soil quality is being/ will be tested
Biological Environment
a. Terrestrial
Ecology
Positive as greenbelt of appropriate
width has been developed and
maintained by SCL in the area
-
b. Aquatic Ecology No impact as no effluent is being / will
be discharged outside the plant
premises
-
Socio-economic
Environment
Overall development of the area in
respect of the infrastructure
development, educational growth,
health facilities etc.
-
Considering all the above, it may be observed that the proposed expansion project will remain an
eco-friendly, which will produce very negligible dust emission and have no effluent discharge.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - V of Final EIA / EMP Report
M/s. Shree Cement Ltd. 144 JM EnviroNet Pvt. Ltd.
CHAPTER-V
ANALYSIS OF ALTERNATIVES (TECHNOLOGY AND SITE)
5.1 ANALYSIS OF ALTERNATIVES
As per EIA Notification dated 14th Sept., 2006 as amended from time to time; the Chapter on
Analysis of Alternatives (Technology & Site) is applicable only, if the same is recommended at
the Scoping stage.
As per the ToR points issued by MoEFCC, New Delhi vide letter no. J-11011/343/2012-IA II (I) dated
10th Feb., 2016 for the proposed expansion project, the Analysis of Alternatives (Technology &
Site) is not required.
The existing technology used by SCL for manufacturing of cement is one of the best and proven
technologies; hence, no alternative technology has been analyzed.
Since, the proposed expansion project by SCL near Village: Ras, Tehsil: Jaitaran, District: Pali
(Rajasthan) will be done on additional available area within the existing plant premises; hence, no
alternative site is considered for the proposed expansion activity.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 145 JM EnviroNet Pvt. Ltd.
CHAPTER - VI
ENVIRONMENTAL MONITORING PROGRAMME
6.1 INTRODUCTION
Post Project Monitoring is an essential part to check the impact of project related activities.
Hence, monitoring of various environmental parameters is being / will be carried out on a regular
basis to ascertain the following:
Status of Pollution within the plant site and in its vicinity.
Generate data for predictive or corrective purpose in respect of pollution.
Examine the efficiency of pollution control system adopted at the site.
To assess environmental impacts.
Monitoring is being/ will be carried out at the site as per the norms of CPCB.
Environmental Monitoring Programme is being/will be conducted for various environmental
components as per the conditions stipulated in Environmental Clearance Letter issued by
MoEFCC, New Delhi and Consent to Establish / Consent to Operate issued by RSPCB.
Six monthly compliance reports are being/will be submitted on regular basis to MoEFCC, New
Delhi by 1st of June and 1st of December. Monthly compliance Report for conditions stipulated in
CTE/CTO are being/will be submitted to RSPCB on regular basis.
Various environmental components and pollution sources, which will be monitored under
environmental monitoring programme are stack emission, ambient air quality, water quality and
noise levels. Details of the Environmental Monitoring programme, which will be undertaken for
various environmental components, are detailed below.
6.2 FORMATION OF ENVIRONMENTAL MANAGEMENT CELL (EMC)
In order to maintain the environmental quality within the standards, regular monitoring of various
environmental components is necessary. M/s. Shree Cement Ltd. (SCL) has a full-fledged
Environmental Management Cell (EMC) at Shree Cement Ltd. near Village: Ras, District: Pali
(Rajasthan) for environmental monitoring and control. The EMC team takes care of pollution
monitoring aspects and implementation of control measures.
A group of qualified and efficient engineers with technicians have been deputed for maintenance,
up keeping and monitoring the pollution control equipment, to keep them in working at the best
of their efficiencies.
6.2.1 Structure of EMC
Structure of Environment Management Cell at Shree Cement Ltd. is given in Figure 6.1.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 146 JM EnviroNet Pvt. Ltd.
Figure 6.1: Structure of EMC at Shree Cement Plant (Pali)
6.2.2 Responsibilities of EMC
The responsibilities of the EMC include the following:
Environmental monitoring of the surrounding area.
Timely Commissioning of pollution control equipments and facilities.
Specification and regulation of maintenance schedules for pollution control equipments.
Ensuring that standards are maintained.
Developing the green belt.
Ensuring optimum water usage.
Carrying out the Environmental Management Plan.
Organizing meetings of the Environmental Management Committee and preparation of
report and submission of such reports to management
Coordination for all statutory requirements like submission of applications / Reports for
obtaining consents, Environmental clearances, authorization etc
6.3 MEASUREMENT METHODOLOGIES
6.3.1 Instruments to be used
The following instruments will be used for data collection work in the monitoring Schedule:
1. Respirable Dust Sampler (RDS)
2. Fine Particulate Matter (FPM) Sampler
3. Stack Monitoring Kit
4. Sound Level Meter
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 147 JM EnviroNet Pvt. Ltd.
6.3.2 Monitoring Programme
The post project monitoring will include details of any major/ minor impact in the core zone and
area within buffer zone for the following parameters: -
Micro-meteorological data
Ambient air quality monitoring
Stack monitoring
Noise level monitoring
Water quality and level monitoring
Medical Check-up of the employees.
6.3.3 Monitoring Schedule
Details of the environmental monitoring schedule / frequency, which will be undertaken for
various environmental components, as per conditions of EC / CTE / CTO are given in Table - 6.1.
Table - 6.1
Frequency for Post Project Monitoring
S. No. Description Frequency of Monitoring
1. Meteorological Data Hourly
2. Ambient Air Quality Continuous monitoring
3. Stack Monitoring Continuous monitoring and monthly
4. Water Quality Pre- monsoon and Post-monsoon
5. Noise Level Monitoring Monthly
6. Medical Checkup of Employee Yearly
6.3.4 Methodology Adopted
Post project monitoring will be carried out as per conditions stipulated in Environmental Clearance
Letter issued by MoEFCC, New Delhi; Consent issued by RSPCB as-well-as according to CPCB
guidelines.
Plant site is considered as core zone and the area lying within 10 km radius from the plant site is
considered to be the buffer zone where slight impacts may be observed on physical and biological
environment and that too is occasional.
Details of Post Project Monitoring Programme are given in Table - 6.2 and 6.3.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 148 JM EnviroNet Pvt. Ltd.
Table - 6.2
Post Project Monitoring
Attributes Sampling Measurement
Method
Test Procedure
Network Frequency
A. Air Environment
Meteorological
• Wind speed
• Wind direction
• Dry bulb
temperature
• Wet bulb
temperature
• Relative humidity
• Rainfall
Minimum
1 site
in the project
impact area
Regularly in one
season by
Weather
Monitoring
Station
Mechanical/
automatic weather
station
-
Pollutants
• PM10
4 locations in
the project
impact area
(1 location in
upwind side, 1 in
downwind side /
impact zone,
other nearby
receptors)
Revised National
Ambient Air
Quality Standards
(NAAQS) vide
MoEF circular,
dated 16.11.2009
Gravimetric method
-
• PM2.5 Gravimetric method -
• SO2 EPA Modified West
& Geake method
Absorption in Potassium
Tetra Chloromercurate
followed by Colorimetric
estimation using P-
Rosaniline hydrochloride
and Formaldehyde (IS:
5182 Part - II).
• NO2 Arsenite modified
Jacob & Hochheiser
Absorption in dill NaOH
and then estimated
colorimetrically with
sulphanilamide and N (I-
Nepthyle) Ethylene
diamine Dihydrochloride
and Hydrogen Peroxide
(CPCB Method).
• CO Non Dispersive Infra-
Red (NDIR)
Spectroscopy
-
B. Stack Monitoring
Pollutant
PM
Stack of the kiln,
coal mill,
cement mill,
clinker cooler
and boiler.
As per CPCB Guide
Line and Indian
Standard 11255
(1985).
As Per CPCB Guide
Line
Gravimetric method
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 149 JM EnviroNet Pvt. Ltd.
Attributes Sampling Measurement
Method
Test Procedure
Network Frequency
SO2 Stack of the kiln
and boiler.
As per CPCB Guide
Line and Indian
Standard 11255
(1985).
As Per IS-11255 part
(2) 1985 (Absorbing
Solution of H2O2,
Isopropanol
Reagent)
Absorption in H2O2,
Isopropanol followed by
Colorimetric estimation
using Sulphuric acid and
Barium Chloride as Per IS-
11255 part (2) 1985
NO2 Stack of the kiln
and boiler.
As per CPCB Guide
Line and Indian
Standard 11255
(1985).
As Per IS-11255 part
(7) 2005 with NOx
flask assembly.
Absorption of Sample in
NOx flask assembly
Followed by Colorimetric
estimation using Phenol-
di-sulphonic acid and
other reagent as Per IS-
11255 part (7) 2005
C. Water Environment
pH, Turbidity, Colour,
Odour, Taste, TDS,
Total Hardness,
Calcium hardness,
Magnesium hardness,
Chloride, Fluoride,
Sulphate, Nitrates,
Alkalinity, Iron, Copper,
Manganese
Set of grab
samples during
pre and post-
monsoon for
ground and
surface water
for 10 km
distance
Diurnal and Season
wise
As per IS 10500- Samples for water quality
should be collected and
analyzed as per: IS: 2488
(Part 1-5) methods for
sampling and testing of
Industrial effluents.
Standard methods for
examination of water and
wastewater analysis
published by American
Public Health Association.
D. Noise
Noise levels at Day &
night time -Leq dB (A)
project
Boundary, High
noise
generating
areas within the
core zone
Quarterly / Half
yearly
As per CPCB norms As per CPCB norms
6.4 LOCATIONS OF MONITORING STATIONS
The location of the monitoring stations will be selected on the basis of prevailing micro-
meteorological conditions of the area like Wind direction and Wind speed, Relative Humidity,
Temperature.
4 AAQM stations are being selected (including minimum 1 locations in upwind side, more sites in
downwind side / impact zone) to assess ambient air quality of the area. Noise level monitoring will
be carried out on plant boundary and in high noise generating area within the plant site. Water
and soil monitoring locations will be decided on the basis of general slope of the area and
drainage pattern. Locations for the post project monitoring are given in Table - 6.3:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 150 JM EnviroNet Pvt. Ltd.
Table - 6.3
Locations for Post Project Monitoring
S. No. Description Location
1. Ambient Air Quality Plant Site and as per EC / CTO conditions
2. Stack emissions Plant Site
3. Noise Level Monitoring Plant Boundary and as per EC / CTO conditions
4. Water Level and Quality Nearby Ground water sources
5. Health Check-up Dispensary
6.5 DATA ANALYSIS
Monitoring data analysis will be done by MoEFCC approved laboratory as per CPCB guidelines and
timely submitted to concerned authority (specified in Environment Clearance Letter issued by
MoEFCC, New Delhi and Consent issued by RSPCB) on regular basis.
6.6 DETAILED BUDGET
The budget proposed for the expansion project and that for the environmental protection
measures is given as below:
Capital Cost of the Project: Rs. 755 Crores
Cost for Environmental Protection Measures:
Capital Cost: Rs. 51 Crores
Recurring Cost: Rs. 1.0 Crores / annum
EMP Cost Break-up is given in Table - 6.4 below:
(Rs. In Crores)
S. No. Particular Capital CostRecurring Cost /
annum
1. Air Pollution Control 50.0 0.8
2.Water Pollution Control and Rain Water Harvesting
MeasuresNil Nil
3. Environment Monitoring and Management 0.6 0.1
4. Green Belt Development 0.4 0.1
Total 51.0 1.0
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 151 JM EnviroNet Pvt. Ltd.
CHAPTER - VII
ADDITIONAL STUDIES
7.1 INTRODUCTION
As per EIA Notification dated 14th September, 2006, as amended from time to time; First Technical
Presentation (for ToR approval) for the proposed expansion project was held before EAC (I) on
11th Feb., 2015 MoEFCC, New Delhi has suggested various Terms of Reference (ToRs) for the
preparation of Environmental Impact Assessment (EIA) and Environmental Management Plan
(EMP) Report vide letter no. J-11011/343/2012-IA II (I) dated 10th Feb., 2016.
As per the ToRs prescribed by MoEFCC, New Delhi, the following Additional Studies were carried
out for the proposed expansion project:
1. Public Consultation
2. Hydro-geological Study and Rainwater Harvesting Plan
3. Risk Assessment and Disaster Management Plan
7.2 PUBLIC CONSULTATION
Public Hearing for Proposed Expansion of Integrated Cement Plant - Clinker (11.2 to 15.0 Million
TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum
(1560 TPD) and DG Sets (1000 to 2000 KVA)Near Village: Ras, Tehsil: Jaitaran, District: Pali
(Rajasthan) by M/s. Shree Cement Ltd. was conducted on 20th April, 2016 at 3:00 PM at Office, Sub
Divisional Officer, Jaitaran, District - Pali (Rajasthan).
Details of the Public Hearing Proceedings are appended herewith the Final EIA/EMP Report:
Public Hearing Proceedings
Public Hearing Notice published in Newspapers Dainik Bhaskar and Dainik Navjyoti
dated 18th March, 2016
Photographs of Public Hearing
Action Plan for the issues raised during Public Hearing.
7.2.1 Public Hearing Proceedings
Public Hearing Proceedings (Hindi and English translation) along with attendance sheet have been
enclosed as Annexure - 12 along with this Final EIA/EMP Report.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 152 JM EnviroNet Pvt. Ltd.
7.2.2 Public Hearing Notice published in Newspapers Dainik Bhaskar and Dainik Navjyoti dated
18th March, 2016
7.2.3 Photographs of Public Hearing
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 153 JM EnviroNet Pvt. Ltd.
7.2.4 Action Plan for the issues raised during Public Hearing
S.
No.Name of the Person Issues / Points / Opinions of Local Public Reply by the Project Proponent
Action Plan along with Budgetary
Allocation
1. Employment
Mr. Pappu Kathat, Mr. Mangla
Paras Kathat, Chaina, Village -
Bhagatpura, Tehsil - Jaitaran,
Pali
There is no objection for the project from villagers of
Bhagatpura.
We thanked for their support. -
Mr. Kaluram Gurjar, Village -
Nimbeti, Jaitaran, Pali
No objection from expansion.
Group of Villagers They said that due to Shree Cement, there is
increased employment opportunity with in the area
along with development. No one has any problem
with expansion of the Plant.
Villagers support was welcomed and appreciated by us.
Employment has already been provided to the local
people. More employment will be provided to local
people as per requirement and their qualification in
future also.
Company has already provided
employment to 1325 People from
the local area (Pali).
In the proposed expansion, local
will be given preference as per
their qualificationsGroup of Villagers People are getting employment nearby their houses
Mr. Ajeet Singh, Village Babra,
Mr. Amar Singh, Village Ras
Mr. Javan Singh village
Andheri, Tehsil - Jaitaran, Pali
No objection from expansion, there will be overall
development of the area, with expansion of industries
there is increase in employment
Company has employed total 3311 persons in the
present plant, out of them 40% are from Pali district and
90% from Rajasthan.
Additional 100 people will be required
for expansion; priority will be given
to local people based on their
qualification
Mr. Paras, Mr. Ugmaram, Mr.
Raju Bhai Bhakar Paima,
Mr. Raju, Village Bhairuji Ki
Dhani, Tehsil - Jaitaran, Pali
Our villagers have no objection, with plant expansion.
Our few unemployed people will also get
employment
Kaluram, Rajasthan Situ
Union, Jaitaran, Pali
No objection for the project, Company should provide
more employment and make them regular
Mr. Raj Kathat, Arjun Kathat,
Jaitaran, Pali
No objection from expansion, as with expansion our
400 to 500 people will get employment
Mr. Lunaram Tanwar, Ex.
Director, Krishi Upaj Mandi
Samiti, Jaitaran, Pali
70 % of the people of Ras Panchayat got employment
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 154 JM EnviroNet Pvt. Ltd.
S.
No.Name of the Person Issues / Points / Opinions of Local Public Reply by the Project Proponent
Action Plan along with Budgetary
Allocation
2. Environment Related
Mr. Tej Singh Gurjar, Village
Ras,
He asked for pollution plan. Company has prepared the detailed EIA/ EMP Report
involving pollution plan and submitted to various
departments to the Ras Panchayat, SDM Office Jaitaran,
Public Relation Officer Pali District, District Collector
Pali, District industries center Pali, Member Secretary
RSPCB Jaipur, RO RSPCB Pali, RO MoEFCC Lucknow.
Company has proposed Rs. 51 Crores
as capital cost for Environmental
Protection measures and proposed
Rs. 1.0 Crores / Annum as recurring
cost.
Mr. Puran Singh, Mr. Govind,
Rakesh, Seema, Mr. Suva Lal,
Village Butiwas Jaitaran, Pali
No objection for the project, as there is no pollution
from the industry
All best available pollution control measures and best
practices are adopted for control of emission and are
well within the norms at the plant boundary and from
stack.
Entire nearby area is unirrigated and yield is in rainy
season and there is no dust deposition on the crops in 10
to 15 km area due to cement plant.
No industrial waste water is generated from cement
manufacturing process. RO Reject water from CPP and
reused 100% in synthetic gypsum manufacturing and ash
quenching.
Domestic wastewater is treated in STP and treated
water is utilized for greenbelt development / plantation.
Dust collected from air pollution control equipment is
100% recycled back into the process.
Only used oil is generated as HW which is sold to CPCB
authorized recycler.
Mr. Lunaram Tanwar, Ex.
Director, Krishi Upaj Mandi
Samiti, Jaitaran, Pali
Industry is not causing any pollution
Mr. Shivlal Gurjar, Village -
Gopaldas (Babra), Jaitaran,
Pali
We have no objection for the Plant expansion as plant
is not causing any pollution
Mr. Dayalram Gurjar, Village -
Kheda (Ras), Jaitaran, Pali
Rekha Tailor, Pratapi,
Jaitaran, Pali
Mr. Arvind Singh (State
General Secretary) Centre for
public rights and rural
development, Village
Sevariya, Jaitaran, Pali
He said that the company has not paid any attention
to the basic problem of farmers like water and harm
caused to the fields due to dust.
Company has pose a serious harm in respect to the
pollution to the area. Villagers of Bhimgarh,
Bhagatpura, Khera, Jawangarh, Kanyakheri, Butiwas,
Ramawas, Ras, Roopnagar, Sewariya, Ratangarh,
Rabriyawas, Ballupura, Babra, Gopalpura, Tookra,
Balara, Areni, Kundal, Nimbeti, Patan, Kesarpuraetc
are facing serious problem due to pollution and it has
become very difficult for the villagers of Bhimgarh to
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 155 JM EnviroNet Pvt. Ltd.
S.
No.Name of the Person Issues / Points / Opinions of Local Public Reply by the Project Proponent
Action Plan along with Budgetary
Allocation
live in the area due to Pollution.
Environment of the area of 10- 15 km of the plant
radius has been polluted due to Hazardous gases,
dust released by the plant.
Ground water level of the area is decreasing as the
company is withdrawing water.
As per CGWA NOCs, only 23 nos. of bore wells have
been constructed for the withdrawal of 4000 KLD
ground water in Plant, mines and Bagatpura Residential
township and we are maintaining the same.
Cement plant is based on dry process technology. CPP
and WHRS are based on Air Cooled Condenser
Technology.
For buffer zone (10 km radius) total recharge due to
rainfall & irrigation return flow at study year rainfall
works out to be 32.87 mcm/annum. Total discharge
works out to be 12.81 mcm/annum & stage of
development is 38%.
Total artificial groundwater recharge for plant, outside
area and mines comes out to the tune of 1.93 mcm per
annum against the total ground water use of 1.38
mcm/annum.
Ground water level (m) in the area is given as below:
Year Pre-monsoonPost-
Monsoon
Rainfall
(mm)
2011 19.5 - 22.4 17.8 - 20.8 640
2012 19.9 - 21.9 10.2 - 13.8 412
2013 18.0 - 20.6 18.2 - 202 583
2014 20.4 - 23.4 11.9 - 19.2 557
2015 20.1 - 22.6 14.2 - 20.2 525
-
Power plant and gypsum plant effluent is acidified the
remaining water is not fit for drinking &farms.
Part of the waste generated is being/ will be dumped at
earmarked waste dumping sites within the mine lease
which is being/will be stabilized by the plantation and
-
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 156 JM EnviroNet Pvt. Ltd.
S.
No.Name of the Person Issues / Points / Opinions of Local Public Reply by the Project Proponent
Action Plan along with Budgetary
Allocation
rest of the waste will be backfilled into part of
excavated area
3. Plantation
Group of Villagers Villagers told that they are satisfied with afforestation 63.8 ha (34% of the total existing plant area i.e. 187.5 ha)
has already been developed under Greenbelt/ Plantation
Additional 14.5 ha will be further developed under
Greenbelt / Plantation
Company has proposed Rs. 0.4
Crores as Capital Cost for Greenbelt
development.
4. ESC Activities
Group of Villagers Villagers said that due to Shree Cement drinking
water problems has been resolved
Water is being supplied in nearby area in summer. Company has already spent Rs.
4.21 lacs for supplying of 674
water tankers in 11 nearby villages
for drinking water arrangement.
Company has proposed Rs. 95
lacs for Drinking water
arrangement for local area for
next 10 years.
Group of Villagers They told that Shree Cement helped in construction
of School and Hospital In villages.
Company is doing following in the area of Health and
educational activities
Health Activities:
1. Mobile Health Camps
2. Mega Health Camps
3. Promotion of Institutional Delivery.
4. Transport Facility for delivery cases.
5. Adoption of Govt. Health Centers under PPP
Scheme
Education Activities:
1. Shree ki Pathshala
2. Computer Literacy Program
3. ITI Scholarship
4. School Support Program, such as Bal Divas
5. Construction of School Room with Verandah
6. Financial Support for Construction of Shed
Company has spent Rs.21.06 for
Health, sanitation and Family
welfare programmes and
Rs.63.40 for Educational
promotion programmes
Company has proposed Rs. 200
lacs for Health and Family Welfare
Programmes and Rs. 144 lacs for
Education Promotion
Programmes for next 10 years
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 157 JM EnviroNet Pvt. Ltd.
S.
No.Name of the Person Issues / Points / Opinions of Local Public Reply by the Project Proponent
Action Plan along with Budgetary
Allocation
7. Training of Teachers
8. Teaching Learning Material
9. Adoption of 11 Govt. Schools under PPP
Scheme
Group of Villagers Villagers are satisfied with the C.S.R. done by Shree
Cement and there is no any problem like pollution
Various CSR activities such as Health & family welfare
programmes, Education Promotion programmes,
Women empowerment & development programmes,
Contribution in religious and social programmes and
community infrastructure development projects such as
development of community centre, construction of
roads, providing school infrastructure etc. are being/ will
be carried out by the company
Company has already spent
Rs.461.49 Cr from April 2015 to
March 2016in various CSR
activities
Company has earmarked
Rs.1887.9 Lakhsfor Various C.S.R.
activities for next 10 years
Mr. Ajeet Singh, Village Babra,
Mr. Amar Singh, Village Ras
Mr. Javan Singh village
Andheri, Tehsil - Jaitaran, Pali
CSR activities will help in the development of the area
Mr. Puran Singh, Mr. Govind,
Rakesh, Seema, Mr. Suva Lal,
Village Butiwas Jaitaran, Pali
plantation is done in our villages and time to time
medicines are also provided by the company. Our
Farmers are also benefitted by the CSR activities of
the company.
5. Others
Mr. Arvind Singh (State
General Secretary) centre for
public rights and rural
development, Village
Sevariya, Jaitaran, Pali
Company is doing ill-legal blasting in area. Cracks can
be seen in many houses due to vibrations caused by
the blasting as company was allowed to do mining in
only 750 ha of the Nimbeti Limestone mines, but they
are doing much beyond it.
Controlled Blasting by latest blasting technique by using
shock tube detonator (Down line detonator in
combination with noise less trunk line detonators.) is
being carried out. There is no impact of the blasting as
the villages are far from the active benches of mine
lease area. So far none of the nearby villager contacted
us for any such cracks in houses due to our mining
operation
Noise and Vibration level due to
blasting will be measured and
monitored at different villages.
Whenever company comes for environment clearance
their contractors act as local people and give false
statement and company gets clearance. Company
should not be provided environmental clearance.
All documents are available at the office of the
Panchayat, SDM, DM, Dist industry center and Jila
Parishad.
-
When Public hearing held for environment clearance
company is keeping the administration under
darkness and showing false documents.
-
Mr. Rasa Singh Rawat No proper notification was given regarding public Advertisement regarding public hearing conduction was
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 158 JM EnviroNet Pvt. Ltd.
S.
No.Name of the Person Issues / Points / Opinions of Local Public Reply by the Project Proponent
Action Plan along with Budgetary
Allocation
(Panchayat Committee), Ward
No. 13, Gram Panchayat
Member RAS- Sevariya
hearing. Person attending the public hearing are
contractors, person working under the contractors
and the family members of workers of the company.
Free and independent people are not there in the
public hearing as they were not given proper
notification, only people with their attached interest
to the company are present only
List of person attending public hearing should be
made at the administrative level and investigation
should be done. Copy of the list should be given to
our villagers
Public hearing should be canceled and new date
should be issued with proper notification and place
should be at gram panchayat Ras because local
people are poor and they do not have proper
transport facilities.
published on 18th March, 2016 in Dainik Bhaskar and
Dainik Navjyoti. All the work has been done according to
rules and regulations
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 159 JM EnviroNet Pvt. Ltd.
7.3 HYDRO-GEOLOGICAL STUDY AND RAINWATER HARVESTING PLAN
Hydro-geological Study Report along with Rainwater Harvesting Plan has been enclosed as
Annexure - 3 along with this Final EIA/EMP Report.
7.4 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN
7.4.1 Risk Assessment and Damage Control
Risk assessment is the determination of quantitative or qualitative value of risk related to a
concrete situation and a recognized threat.
Activities requiring assessment of risk due to occurrence of most probable instances of hazard
and accident are both onsite and off-site.
7.4.2 Hazard Identification and Risk Assessment (HIRA) for Integrated Cement Project
Cement manufacturing industry is labor intensive and uses large scale and potentially hazardous
manufacturing processes. The industry experiences accident rates that are high compared with
some other manufacturing industries. Cement industries experiences risk of a number of hazards
inherent to the cement production process. Following hazards may occur:
Exposure to High temperatures;
Physical Hazards;
Events pertaining to Manufacturing Process;
Fire;
Explosion;
Electrocution;
Natural and Manmade hazards.
These mainly impact on those working within the industry, although health hazards can also
impact on local communities. The potential hazardous areas and the likely accidents with the
concerned area have been enlisted below in Table - 7.1.
Table - 7.1
Possible Hazardous Locations onsite
S. No. Hazardous Area Likely Accident
1. Boiler Area Explosion
2. Electrical rooms Fire and electrocution
3. Transformer area Fire and electrocution
4. Cable tunnel Fire and electrocution
5. Storage yard Sliding
6. Crushing and grinding unit Fatal accident
7. Chimney Air pollution
8 Coal/ fuel storage area Fire and spillage
9. Turbine room Explosion
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 160 JM EnviroNet Pvt. Ltd.
Exposure to High Temperature
The principal exposures to heat in this sector occur during handling of hot raw meal (Powdered
limestone, laterite additives etc. heated in a pre-heater cyclone), hot clinker and operation &
maintenance of kilns or other hot equipment. Recommended prevention and control techniques
include the following:
Shielding surfaces where worker s proximity and close contact with hot equipment is
expected,
Using personal protective equipment (PPE), as needed (e.g. insulated gloves and shoes);
Minimizing the work time required in high temperature environments by implementing
shorter shifts at these locations.
Physical Hazards
Injuries during Project operation are typically related to slips, trips, and falls; contact with falling /
moving objects; and lifting / over-exertion. Other injuries may occur due to contact with, or
capture in, moving machinery (e.g. dump trucks, front loaders, forklifts). Activities related to
maintenance of equipment, including crushers, mills, mill separators, fans, coolers, and belt
conveyors, represent a significant source of exposure to physical hazards. Such hazards may
include the following:
Falling / impact with objects
Hot surface burns
Transportation
Contact with allergic substances.
Management measures to prevent the physical hazards in the plant
Any person working on equipment with moving parts will personally ensure the equipment
is de-energized, isolated and locked/tagged out.
Any person working from a position with the potential risk for a fall from height will use fall
protection.
Any person doing flame welding, cutting or brazing in the proximity of any flammable
material will obtain PPE.
Safety helmets to be used to protect workers below against falling material.
Barriers like a toe boards or mesh guards is to be provided to prevent items from slipping or
being knocked off the edge of a structure.
Danger areas are to be clearly marked with suitable safety signs indicating that access is
restricted to essential personnel wearing hard hats while the work is in progress.
In case of any accident immediate and proper medical care shall be provided at the plant
site.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 161 JM EnviroNet Pvt. Ltd.
Events pertaining to the manufacturing process
The following areas are identified as hazard prone incase of Integrated Cement Plant where
Disaster management plan is required.
(i) Handling of Coal and Pet coke
1. The coal and pet coke is received through road and railway and stored in Covered Stockpile
and wind breaking wall arrangement with arrangement of water sprinkling. The possible
hazards are envisaged due to the slipping of wagon during unloading.
2. During summer season, there is chance of coal catching fire due to spontaneous heating.
3. Effective sprinkling systems should be provided all-round the coal storage yards.
(ii) Handling of fine dust
The hot raw meal (Powdered limestone, laterite additives etc. is heated in a multi - stage pre
heater cyclone) is stored in the raw meal silos. It is very common that the hot raw meal gets
jammed in the chute and screw conveyors. During the maintenance process, the operator
generally works in the pre-heater cyclone and other areas. Always there is a possibility of hazard
that the jammed material falls on the workers and due to hot temperature of the material,
possibility of injury may occur to the worker, sufficient care should be taken in the maintenance
operations.
(iii) Handling of Hot Clinker
The hot clinker is transported by chain conveyors to the top of the silo or stock pile for storage.
During this operation, there is a possibility of spill out of hot clinker. Proper care for the conveyor
system and the bund wall for the clinker stock pile should be provided.
(iv) Handling of Cement
Cement is the fine dust which requires proper care in handling, storage and packing to avoid any
health hazards.
Fire
Fire can be observed in the boiler area, Coal storage yard, Fuel spillage, Electrical rooms,
Transformer area etc. due to accidental failure scenario.
Explosion
Explosion may lead to release of heat energy and Pressure waves. Table 7.2 shows tentative list of
Damages envisaged due to different heat loads.
Table - 7.2
List of Damages Envisaged at Various Heat Loads
Sr.
No.
Heat loads
(kW/m²)
Type of Damage Intensity
Damage to Equipment Damage to People
1 37.5 Damage to process equipment 100% lethality in 1 min. 1% lethality in 10 sec.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 162 JM EnviroNet Pvt. Ltd.
2 25.0 Minimum energy required to ignite
wood
50% Lethality in 1 min. Significant injury in 10
sec.
3 19.0 Maximum thermal radiation
intensity allowed on thermally
unprotected equipment
--
4 12.5 Minimum energy required to melt
plastic tubing
1% lethality in 1 min
5 4.0 -- First degree burns, causes pain for exposure
longer than 10 sec.
6 1.6 -- Causes no discomfort on long exposures
Source: World Bank (1988). Technical Report No. 55: Techniques for Assessing Industrial Hazards. , Washington, D.C: The World Bank.
Electrocution
Fatal Accident due to carelessness during working hours may lead to electrocution. Probable
areas where chances prevail are enlisted in Table - 7.2.
Natural and Manmade Calamities which can lead to Emergency
(a) Earthquake
The Pali District area falls under the seismic zone-II, which is the low risk quake and may trigger
into a technological disaster, includes collapse of old structures, buildings leading to fire and
explosion. Earthquake cannot usually be forecasted and therefore precautions immediately prior
to such event are not usually possible. Apart from some of the counter-measures to be taken in
foreseeable cases, emergency recovery plan has been considered by the emergency management
team as per the situation and site conditions as follows:
Step Activity Action By
Preparedness • Identify and constitute Emergency Response Team
• Identify ECC, if the identified ones are damaged
• Control centers to be equipped withCommunication facilitiesEmergency vehicles/ equipmentList of emergency contacts and suppliersMedical facilities
Plant Key Person
Action during
effective period
• Do not panic. Raise alarm
• Avoid standing near to windows, external walls
• Stand near the columns or duck under sturdy furniture.
• Assemble at emergency assembly point as there may beaftershocks
Individual(s)
Action after
effective
Period (Establish
Emergency Control
Center. Site Main
Controller to direct
all activities)
• Take head count
• Activate emergency plan as situation demands
• Assess situation and initiate shut down of plants (ifrequired)
• Initiate search and rescue (if required)
• Provide first aid to victims. Remove casualties
• Key persons to report to site
• Assess damage
• Undertake
Site Incident
Controller Site Main
Controller
Coordinators Fire
and Security, Safety,
Material, Medical, and
Plant Key Person
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 163 JM EnviroNet Pvt. Ltd.
(b) Storm
The contingency actions during storm shall be based on the weather forecasts obtained from
meteorological stations and the local meteorological department. Some of the important actions
to be carried out are as follows:
Prior to Storm
Establish regular contact with the local meteorological department.
Establish distances from storm in order to execute preparatory actions in a shorter time.
Appraise the factory operations / installations and consider the consequences that the
emergency might have on operations and personnel.
Check the availability of tools, batteries, non-perishable foods and other materials that might
be required.
Review all operations carefully to ensure that systems in jeopardy are taken care of or shut
down.
Ensure the readiness of first aiders, emergency vehicles, medical centre, medicines etc.
Metallic sheets, loose materials, empty drums and other light objects shall be properly
secured.
Flush the drainage systems.
During Storm
Remain calm.
Do not go outdoors.
Do not seal the office completely as the suction created by the difference in atmospheric
pressure inside and outside can rip open a window or door by breaking window glass panes.
After the Storm
Do not touch electric lines.
Stay away from the disaster area.
Take special precautions in driving vehicles since the under-pavement could cave in due to the
weight of automobile.
(c) Flood
Though flood in this region is rare by virtue of its location from rivers and dams. The HFL alarm
should be provided. During rainy season nallah should be monitored by the supervisors in all
shifts.
(d) Air Raid
Air raid warning would be obtained from the District Emergency Authority or Defense Authorities,
during which total blackout of the entire complex should be considered. Some of the contingency
actions to be considered during an air raid are as follows:
The Aviation Lights installed on highest point inside the factory should be switched off
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 164 JM EnviroNet Pvt. Ltd.
All the lighting on the Streets should be put off
All the plant lighting should be put off
Brown curtains shall be provided for all windows inside the building
Other emergency actions should be followed in addition as per the general procedure
(e) Bomb Threat
In view of the probable acts of terrorism, the possibility of receiving bomb threats or the sabotage
cannot be ruled out. Therefore, consider all bomb threats as genuine and act accordingly keeping
in mind the safety of the people in the factory and the property. For such situation, the security
people should take action under the guidance of the Section Head (Security). The Bomb threats
may be received in writing or may be received on phone. The expected actions by telephone
receiver are as follows:
Keep the caller on the line as long as possible. Request him to repeat the message, listen
carefully as every word spoken by the person has to be recorded mentally or penned down.
If the caller does not indicate the location of the bomb or the time of possible detonation, it
is advisable to try to ask him for this information.
Pay particular attention to peculiar background noises such as motors running, background
music and any other noise, which may give a clue as to from where the call is being made.
Listen closely to the voice (male, female), voice quality (calm, excited), accents and speech
impediments. Immediately after the caller hangs up, report should be made to the
immediate senior manager or security officer on duty about all the above details.
In consultation with SMC, the Legal-Coordinator can immediately inform the nearest Police
station over phone and also Bomb diffusion squad.
If the location is identified, cordon-off the area and ask people to leave the area and
assemble at designated assembly point.
During strikes police will be informed by the Legal-Coordinator in advance and taken their
help to maintain law and order.
(f) Food and Water Poisoning
Food and water poisoning to a no of persons, due to canteen food or other means, is another
scenario which can leads to major emergency. In this case Medical Officer should be informed
immediately by the Sr. most person available at site and then to incident Controller(IC) and Site
Main Controller (SMC). In such situation doctors should act and if situation demands additional
help such as ambulances, doctors and medicine should be arranged from nearby factories and
hospitals. For such situations SMC may decide whether siren is required to blow or not and
arrange to inform key persons in the factory and if required set up Emergency Control Centre
(ECC) at Hospital. Functional Head (FH) of HR should rush to ECC and assist SMC for informing
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 165 JM EnviroNet Pvt. Ltd.
nearby hospitals, doctors and govt. authorities in consultation with the doctor. Plan to deal with
food and water poisoning can be divided in following stages:
Step Activity Action By
Planning and Preparedness • Maintain adequate inventory/ supply of medicines, saline
water etc. and identify resources to obtain during
emergency
• Impart awareness training regarding food/ water
poisoning
MedicalCoordinator
Action during effective
Period (Establish Emergency
Control Center. Site Main
Controller to direct all
activities)
• Identify the contaminant source
• Seize contaminated material and keep out of circulation
• Take preventive measures for avoiding recurrence
• Inform all concerned
• Arrange to analyze samples
• Arrange alternate supplies
• Arrange medical assistance to the victims
• Mobilize assistance from outside (if necessary)
Site Main Controller,
Medical coordinator
and QC person
Action after effective period • Conduct detailed epidemiological investigation to
identify the cause of contamination
• Take appropriate preventive measures to avoid
recurrence
• Follow up on causalities
Site Main Controller
Medical coordinator,
and FH (HR)
High Risk Categories and Preventive Measures
High Risk Categories and Preventive Measures are given in Table - 7.3.
Table - 7.3
High Risk Categories and Preventive Measures
High Risk Categories Prevention
Contractors Contractor Safety Management
Young/Temporary Employees Special Safety Induction Training
Direct Causes
Traffic & Mobile Plant Driver Training
Falls from Heights, Objects falling from
Heights
Safety Procedures for Work at Heights,
Overhead Protection
Caught in Starting/Moving Equipment Plant Isolation Procedures
7.4.3 Measures for Occupational Health Hazards
Dust Exposure level of shop floor workers is to be appropriately monitored.
Check of the effectiveness of preventive and control measures on regular basis.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 166 JM EnviroNet Pvt. Ltd.
Adequate supplies of potable drinking water are to be provided. Water supplied to areas of
Plant food preparation or for the purpose of personal hygiene (washing or bathing) should be
according to drinking water quality standards.
Where there is potential for exposure to harmful dusts by ingestion arrangements are to be
made for clean eating areas, where workers are not exposed to the hazardous or noxious
substances
Periodic medical hearing checks are to be performed on workers exposed to high noise levels.
Provisions are to be made to provide OHS orientation training to all new employees to ensure
they are apprised of the basic site rules of work at / on the site and of personal protection and
preventing injury to fellow employees
Contractors that have the technical capability to manage the occupational health and safety
issues of their employees are to be hired, extending the application of the hazard
management activities through formal procurement agreements
Ambulances and First aid treatment facilities are made available for any emergency situation.
7.4.4 Disaster Management Plan
Definition
A major emergency in a work is one, which has the potential to cause serious injury or loss of life.
It may cause extensive damage to property and serious disruption both inside and outside the
work. It would normally require the assistance of emergency services to handle it effectively.
Scope
This emergency plan and its associated emergency response procedures have been established to
provide direction to personnel in managing an emergency condition, to ensure the reduction of
impact on environment, health and safety of employees and the visitors.
Objective
This emergency plan establishes the concept of operations for:
a) An assessment of the emergency condition
b) Timely and effective mitigation of the emergency condition
c) Management of emergency response activities
d) Notifications to facility personnel and off-site personnel and organization
e) Recovery from the emergency condition
Elimination will require prompt action by operations and works emergency staff using, for
example, fire-fighting equipment, water sprays etc. Minimizing the effects may include rescue,
first aid, evacuation, rehabilitation and giving information promptly to people living nearby. To
deal with the above emergencies, the Emergency Plan is prepared.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 167 JM EnviroNet Pvt. Ltd.
Emergencies
(a) Stores
Possible Emergency: Possibility of catching fire in stores materials
Preventive Measures
Suitable fire extinguishers, fire hydrant system and fire buckets is being/ will be provided for
fighting the fire during emergency. Stores staff is being/ will be imparted the training for first aid
firefighting to prevent/extinguish the fire at initial stage.
(b) Oil Storage Tank - HSD Underground Tank
Possible Emergency: Possibility of catching fire at the oil storage tanks and fuel oil handling system
and Oil spillage from storage tanks.
Preventive Measures
Area is being/ will be declared as fire hazards area as "No Smoking and No Naked Flame Zone".
Suitable fire extinguishers and fire hydrant system is being/ will be provided at the tank enclosure
area and inside the pump room. Regular scheduled inspections of storage tank and the enclosed
area is being/ will be carried out by the custodian with regard to proper earthling, presence of any
combustible material or growth of wild vegetation, no breaches in the wire fencing, damage in the
dyke wall etc.
No naked flames are being/ will be allowed in and around fuel oil storage areas, if required for gas
cutting/welding job for maintenance of the plant or machinery, a PTW is being/ will be taken for
hot work with all proper safety precautions.
Unloading of petroleum in bulk will not allowed between sunset and sunrise. Tanker engine is
being/ will be switched off before unloading and the tanker is being/ will be earthed.
Dyke walls is being/ will be provided to prevent over flow/spillage of oil, Oil separation pit is being/
will be provided to prevent oil missing with the water drains.
All requirements and conditions of the Explosives License applied under the Petroleum Act, 1934
& Petroleum Rules, 2002 (with latest amendments are implemented in the HSD storage area.
(c) Packing Plant
Possible Emergency: Possibility of catching fire in the bag godown.
Preventive Measures
Declared as "No Smoking or Fire" area.
Suitable fire extinguishers and fire hydrant systems is being/ will be provided for firefighting in
emergency situation.
Permit to work for hot work is being/ will be taken for any welding/gas cutting in that area.
Adequate drainage to immediately drain out the water used in firefighting is being/ will be
provided to avoid water damage. The sheds are being/ will be properly ventilated.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 168 JM EnviroNet Pvt. Ltd.
(d) Silos
Possible Emergency: Collapse of silos
Hazards: Dust emission, material spillage & injury to person & damage to other property
Preventive Measures
• Structural soundness of silos
• To avoid over filing of silos (not to fill the silos up to the brim, not to keep silos too empty to
avoid structural damages)
• Install lighting arrestor at top of the silos bucket elevator
(e) Electrical Transformer
Possible Emergency: Catching fire in transformers
Preventive Measures
• Predictive interlocks are being/ will be provided which will automatically give an alarm/trip the
system.
• In case oil pressure inside the transformer tank increases, buchholtz realy provided will sound
an alarm and if necessary will trip the transformer and thus avoid oil explosion.
• A diaphragm is being/ will be provided at the bottom of explosion vent to vent out high oil
pressure whenever pressure is increased beyond limit.
• Fire extinguishers and sand buckets is being/ will be provided in the transformer room for
firefighting due to explosion or during an emergency.
(f) Transformer Yard and HT/LT Sub-Station
Possible Emergency: Possibility of fire and explosion
Preventive Measures
All transformers are being/ will be separated by brick wall up to the height of transformer.
Soak pits of suitable capacity is being/ will be provided to collect the leaked transformer oil in case
of fire and explosion.
• Periodic maintenance of all electrical machinery apparatus is being/ will be utmost
importance.
• Soundness of insulation, proper ventilation and earthing arrangements is being/ will be
checked regularly by dept.
• Person certified by HOD.
• In case of fire in HT transformer, first of all switch off 33/132 kV Incomer breaker.
• In case of LT transformer fire/explosion, switch off the transformer feeder from HT line.
• Inform emergency control room for fire brigade and other actions.
(g) Electrical Cable Tunnels
Possible Emergency: Catching fire in electrical cables inside the tunnels
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 169 JM EnviroNet Pvt. Ltd.
Preventive Measures
Suitable fire extinguishers are being/ will be provided for fire provided for firefighting. Overall
good housekeeping is being/ will be maintained to avoid any fire risk. Exhaust fan provided to
avoid any suffocation.
(h) Conveyor Belts
Possible Emergency: Catching of fire in conveyors
The main cause for conveyer fire are
Gas cutting/welding
Frictional heat
Preventive Measures:
• Suitable fire extinguishers are being/ will be provided for each transfer towers for firefighting
during emergency
• Full cord system is being/ will be provided throughout. its length to stop it in any emergency
• Preventive checks on frictional parts like drum and lagging of drum are done
• Suitable fire equipment is being/ will be kept at hand during gas cutting/welding
(i) Failure of Lifting Tools & Tackles and Pressure Vessels
Possible Emergency: Injury to person and damage to equipment
Preventive Measures:
• All lifting tools and tackles and pressure vessels is being/ will be tested/examined by
competent person authorized by chief inspector of factories, Govt. of Chhattisgarh as per
statutory requirement and at defined frequency.
• Safe working pressure range is being/ will be maintained in the Air receiver tank/pressure
vessels.
• Safe Working Load will not be violated while using cranes, hoists, ropes, chains and other
lifting tools and tackles, only authorized personnel is being/ will be allowed to handle the
same.
• Regular and periodic maintenance is being/ will be done
(j) Oil Tanker
Possible Emergency: Toppling of Oil Tankers
Preventive Measures:
• Speed limit signboards is being/ will be displayed, no vehicle is being/ will be allowed to move
beyond 20 km/hr.
• In case oil is toppled Plant Inventory dept is being/ will be informed.
• Spray sand on the oil to prevent further spread of oil and oil soaked sand is being/ will be
collected to fill in the land and cover with soil.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 170 JM EnviroNet Pvt. Ltd.
(k) Working at Height
Possible Emergency: Fall from Height
Preventive Measures:
While working at height preventive measure to be taken as per procedure working at height.
In Case of Emergency:
• Inform immediately to Emergency Control Room/ OHC.
• Inform immediately to the Job Execution In-charge
• If a person falls from height and hanging try to immediately provide him any additional
support and arrange for rescue operation by proper available tools ASAP (rope, ladder, And
man basket with crane etc). Stop the job immediately.
• Rescue team member will rush at site with rescue kit.
• Emergency team to act as per Emergency organization structure.
• Rescuers to access the probable risk for rescuing the victim.
• Rescuer has to use double fall protection as precaution (One rope grab fall arrestor/Winch fall
arrestor and another is descender).
• Rescuer to use PN 56 model full body safety harness for rescue operation
• Victim is being/ will be rescued by trained rescuer only.
(l) Stock Pile and Surge Pile
Possible Emergency: Engulfment in Stockpile (Gypsum, Lime)
Preventive Measures:
• Take permission before climbing on stock pile
• Pedestrian to maintain a safe distance from stock pile
• Person to work under close supervision
In case of Emergency:
• Inform immediately to Emergency Control Room / OHC.
• Inform immediately to the Job Execution In-charge
• If a person buried under stockpiles
• Stop the job immediately and related equipment by pushing emergency button if applicable.
• Cordon off the affected area
• Take out the material with the help of section in-charge
• Rescue the affected persons and send to hospital
(m) Fire/Explosion
Possible Emergency: Fire/Explosion in any plant and offices area
Preventive Measures: In the event of fire wherever available; the local fire alarm signal is being/ will
be activated. The fire alarm can be initiated by activation of one of the following systems:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 171 JM EnviroNet Pvt. Ltd.
• Break glass Alarm Systems
• Fire Detection Systems, i.e. Smoke Doctors
7.4.4.1 Onsite Emergency Plan
The onsite emergency management of Shree Cements Ltd. is given here, as the same will be
applied in case of proposed expansion.
Disaster control Management system
The Availability, Organization, and Utilization of Resources for Facility Emergencies
In order to maintain an emergency response capability, certain facilities must be kept in a state of
readiness, and sufficient supplies and equipment must be available. In some cases, it may be
impossible to maintain all of the equipment necessary for all possible emergencies. In these cases,
mutual aid agreements have to be made with neighboring facilities to provide additional support
as necessary. Where the local fire brigade, police or private agencies be called upon, notification
and activation of these organizations are carried out. The reminder of this section is dedicated to
the plant emergency facilities, equipment, and supplies. Following emergency can be classified
according to its use during the response operations:
Emergency Control Center (ECC)
Communication equipment
Alarm systems
Personal protection equipment
Firefighting facilities, equipment and supplies
Medical facilities, equipment, and supplies
Transportation system
Security
Assembly Point
Emergency Control Centre (ECC)
An Emergency control Centre (ECC) is established from which emergency operations are directed
and coordinated. This centre is activated as soon as an onsite Emergency is declared. In Shree
Cement Ltd. ECC is located at security main gate. The ECC consist of one room, located in the area
that offers minimal risk being directly exposed to possible accidents.
During an emergency, emergency management staff, including the main controller will gather in
the ECC. Therefore, the ECC is equipped with adequate communication systems in the form of
telephones and other equipment to allow unhampered communication with the teams involved
in bringing the accident under control and with the external response organization and other
nearby facility personnel. The ECC communication systems are protected from possible shut
down. The ECC has its own emergency lighting arrangement and electric communication systems
operation. We have one alternate arrangement of ECC in the office of P&A Head.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 172 JM EnviroNet Pvt. Ltd.
The ECC is always ready for operation and provided with the equipment and supplies necessary
during the emergency such as:
Updated copies of the On-site Disaster Management Plan
Emergency telephone numbers
The names, phone numbers of external agencies, response organizations and
neighboring facilities
The List of key personnel
The adequate number of telephones (more than two)
Emergency lights
List of fire extinguishers with their type no. and location, capacity etc.
List of Personal protective equipment
Clock
Status boards / message boards
Several maps of the facility for surrounding area showing:
Areas where hazardous materials are stored.
Plot plans of storage tanks, routes of pipelines, and all water permanent lines etc.
The locations where personal protective equipment are stored.
The position of pumping stations and other water sources with hydrant lines.
Roads and plant entrances
Assembly Points in the plant.
Communication Equipment and Alarm Systems
This kind of equipment is absolutely vital for notifying accident; make the emergency known both
inside and outside of the facility, and coordinating, the response actions among the various groups
involved in response operations. Different communications systems can vary in effectiveness,
depending on the task. The most common types installed in the plant are given below.
Sirens
Personal Protective Equipment
Fire Fighting Facilities, Equipment and Supplies
Medical Facilities, Equipment and Supplies
Media Centre
Transportation Systems
Security and Access Control Equipment
Location of Assembly Point :
The Assembly Point are the places where the staff other than the emergency response team and
unaffected personnel can collected safely as these areas are located in Risk Free Zone. The
facilities have been provided near Time Office, Mines Gate & Dispensary.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 173 JM EnviroNet Pvt. Ltd.
Roles and Responsibility
Site Controller
The Functional/ Technical head shall have overall responsibility for the factory and its personnel. In
absence of functional/ technical head, his immediate sub-ordinate shall resume the responsibility
of Site Controller. His duties during emergency shall be:
To assess the magnitude of the situation and decide if employees need to be evacuated
for assembly point(s).
To maintain continuous review of possible development and assess in consultation with
incident controller as to whether the shutting down of the plant or part of the plant and
evacuation of person is required.
To give necessary instructions to liaison officer HOD (P & A) regarding the help to be
obtained from outside agencies like fire-brigade, Police and medical.
To advice liaising officer to pass-on necessary information about the incident to News,
Media and ensure that the evidences are preserved for inquiries to be conducted by
statutory authorities.
Instruct Head (P & A) to head count through time office if necessary.
Arrange for relief of personnel when emergency is prolonged.
Authorize the sounding of the All Clear siren, which will be one continuous long siren for
one minute.
Incident Controller (HOD of the affected section)
The HOD of affected department shall have overall responsibility controlling the incident/
emergency and directing the personnel(s). In absence of incident controller his immediate
subordinate shall resume the responsibility. His duties during emergency shall be:
To act as site controller till site controller arrives.
Proceed to the scene of emergency and assess the situation. Activate the disaster
management plan in consultation with Site Controller.
To inform communication officer about the emergency, control center and direct the
personnel of his department to reach at assembly point if necessary.
To direct all operations within the affected areas with priorities for safety personnels, to
minimize the loss to plant, environment and personnel(s).
To provide advice and information to fire squad, security officer and local fire services
when they arrive.
Co-ordinate with the Head (P & A) for any help from outside agencies if required.
Arrange for rescue of trapped workers and those in a state of shock.
Report / communicate all developments to the Site Controller.
Preserve all evidence for use in the subsequent inquiry.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 174 JM EnviroNet Pvt. Ltd.
Primary Controller:
The Primary Controller is the employee who gives the first information about the
incident/accident. He will responsible for:
To inform office at main gate, his superior of section about the incident/ accident by
verbal/by phone.
To assist fire brigade in its operation and would assist in clearing any obstruction coming in
the way of fire fighting.
To assist rescue team to control the situation if required.
To carry out all instructions received from incident controller.
Liaison Officer (HOD P & A)
HOD (P & A) shall be the liaison officer. He shall be responsible for:
Proceed immediately to the Emergency Control Centre.
Also work as a liaison officer during the emergency.
To contact outside Fire brigade, Police and medical facilities on receiving intimation from
site controller and arrange for the rescue operation.
To ensure that the casualties receive attention.
To inform the relatives of the affected employee(s) at the earliest.
To arrange additional transport if required.
To arrange for relief of personnel and organized refreshment/ catering facility in case the
duration of emergency is prolonged.
To issue authorized statements to news media and ensure that evidence is preserved for
inquires to be conducted by statutory authorities.
To inform communication officer about the emergency, control center and Assembly
point.
To ensure that all non-essential persons are sent to the assembly points.
Produce the list of facility staff on duty and visitors at the premises.
Communication Officer
Incharge internal telephone office shall be the communication officer. He will be responsible for:
1o communicate correct information about the incident/ accident.
To give priority of incident /accident for communication.
HOD (Security)
HOD security / his next sub-ordinate (in absence of HOD security) will be responsible for:
Ensure provision of all applicable measures in affected area.
Ensure entry restriction in affected area.
Control of transportation in affected area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 175 JM EnviroNet Pvt. Ltd.
Control traffic into the facility and ensure that alternate transport is available when need
arises and ensure free access is available for temporary casualties.
Check the availability of emergency Fire Fighting equipment in the security department
and various sections in the plant and make up for shortages time to time.
Arrange the required for handling critical situations during the emergency.
Co-ordinate with the Site /Incident Controller and assume overall responsibility of the fire
fighting operations and other related activities.
Advice the Main Controller if additional fire tender / fire fighting equipment / material / aid
from other agencies is required.
Arrange to close the entire visitor/ other gates.
Ensure that unauthorized persons / vehicles do not enter the facility.
Provide personnel for fire fighting and rescue.
Prevent overcrowding at the scene of the incident.
Medical Coordinator
On hearing the emergency siren or getting the information about emergency he shall immediately
perform following duties.
To attend and provide first-aid to the injured person(s) on priority.
To shift injured person at the earliest to nearby Hospital, if found necessary.
To depute dispensary staff in affected area for first-aid if found necessary for ensuring
immediate medical attention.
Inform all the nearby hospitals of the situation and apprise them of the antidotes that
would be necessary for treatment, if any.
Ensure that records of blood group of all employees are easily accessible if required.
Safety Office
He shall be responsible for:
Rush to the Emergency site.
Monitoring of incident / emergency.
Arrangement of safety appliances.
Advice for provision of all applicable measures in affected area.
Keeping watch of the rescue operation and all other activities and guide them
accordingly.
Conduct mock drill.
Rescue Team
SCL has a rescue team in plant consisting of ten employees from different department. They will
reach to affected site and act as instruction of site controller/ incident controller. Inspite of that
they will be responsible for:
Rescue the person from the affected area and provide first aid to the injured due to fire.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 176 JM EnviroNet Pvt. Ltd.
Assist for rushing casualties to hospitals and report details of casualties to Main
Controller.
Act as runners if required.
Evacuate non-essential personnel and visitors to safe assembly areas.
Fire Fighting Team
SCL has a Fire Fighting team in our plant consisting of seven employees from security department.
They will reach to affected site and act as instruction of site controller/ incident controller/ HOD
security.
Others
Services and Control
SCL has three types of communication systems.
Alarm which is installed at the top of pre-heater U-IV.
Public address system is operated with battery and available with security department. In
case of power failure, we may use this public address system in emergency.
Runner may be used in case of all above system become fail.
7.4.4.2 Emergency Communication
Once the Disaster Management Plan is activated, the Liaison Officer maintains co-ordination with
external agencies from the ECC if required. The co-ordination with external response teams at the
scene of the accident is maintained through the Incident Controller, who is in direct contact with
the ECC.
Emergency Response Actions
This element of emergency plan deals with the actual actions that should be implemented by
personnel in the various functions during the emergency. As and when any emergency happens in
the plant, the same is recorded. The emergency is categorized. The records of the response time
by responsible personnel, Safety Officer also maintain mitigating the impact of hazardous
conditions. The damage caused by such conditions is reviewed and recorded. The response time
and damages are reviewed in the Management Review Meeting and the suitable corrective
actions (e.g. Training of Personnel; increase of resources; change in documentation and any flaw
observed in execution of the plan) are taken. The corrective actions are verified by Mock Drills
which is conducted six monthly. The Operational Procedures outline the actions to be taken by
personnel in the various functions or individuals within the organization in response to the
possible emergency situations envisaged in the hazard evaluation and risk analysis study.
The views of the possible hazards that can arise out of the daily operations in the plant various
measures are adopted to prevent the occurrence of a major accident. This comprises of:
a) Built in safety measures, alarms, trips and interlocks etc.
b) Standard safe operating and maintenance procedures permit system etc.
c) Training of all the involved staff in normal and emergency operating procedures.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 177 JM EnviroNet Pvt. Ltd.
d) Training of all employees in safety, firefighting and first aid.
However, in spite of these precautions, it is required to foresee situation of major accident and
plan for taking timely action to minimize the effects of such incident on the safety and health of
persons working in the plant as well as those situated around the premises. Hence the present
plant is drawn up to serve as the manual of handling major emergencies.
Internal telephone systems are provided at work places. Shift in charge at site and other in charge
also given on call handset (Walkie Talkie) for immediate communication to all concerned. The shift
in charge /Site in charge will immediately inform department Head / in-charge, security and
dispensary (if required). The department head in charge will inform Vice president and factory
manager who according to severity of emergency will inform about the emergency to Senior
President.
Onsite emergency planning for Cement plant
Following onsite measures are being / will be taken to avoid/ minimize the risk of accidents &
other hazards in cement plant and power plant:
(i) Alarm and Communication Systems
Communication is crucial factor in handling an emergency. It is the practice at many plants that
any employee can raise an emergency alarm, so allowing the earliest possible action to be taken
to control the situation.
Raising the alarm is the first step in the implementation of the emergency Plan. It is the practice
that in case of any emergency the person who has seen the incident first may inform to security
and after verification the security at main gate will raise the alarm as direction given below:
A. For an emergency -
Siren - short, intermittent siren.
15 second ON and 5 second OFF for five times
B. All clear
Long continuous siren lasting 1.5 minute.
(ii) Fire-fighting System
In view of vulnerability to fire, effective measures will be taken to minimize fire hazard. Fire
protection is envisaged through hydrant and sprinkler system, designed as per the
recommendation of Tariff Advisory Committee of Insurance Association of India. The following
areas in the power station are mainly susceptible to fire:
Cable galleries
Electrical switchgear/ MCC room
Coal handling areas: Conveyors, transfer points, tunnels and storage yard.
Transformers and turbine oil tank
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 178 JM EnviroNet Pvt. Ltd.
For containment of fire and preventing it from spreading in cable galleries, section wise fire
barriers with self - closing fire resistant doors will be provided. The ventilation systems, if any,
provided in cable galleries will be interlocked with the fire alarm system, so that in event of a fire,
the ventilation system will be automatically switched off. In order to avoid spreading of fire all
cable entries opening in cable galleries, tunnels, channels, floors, barriers etc will be sealed with
non-inflammable/Fire resistant sealing materials.
For detection and protection of the plant against fire hazard, any one or a combination of the
following systems will protect susceptible areas:
Hydrant system.
Automatic high velocity spray system
Medium velocity spray system
Portable fire extinguishers
Fire alarm systems
Fire hydrant points have been provided throughout the premises. Automatic high velocity spray
system has been provided for protection of transformers and cable galleries. Manual medium
velocity spray system has been provided for protection of fuel oil and turbine oil storage tanks and
coal conveyor galleries.
Water for hydrant, spray and sprinkler system has been supplied from the firewater pumps
located in firewater pump house adjacent to Raw Water Reservoir. Portable fire extinguishers of
appropriate types and adequate capacities have been distributed all over the plant to enable
employees in fighting fires in their incident stages. These include Dry chemical powder (DCP),
Foam, CO2, ABC and fire bucket.
Total number of portable fire extinguisher - 773,
Total no. of fire sand bucket - 158
Water monitors - 6.
Table - 7.4 and Table - 7.5 enlist case and Site Specific Fire extinguishers respectively.
Table - 7.4
List of Extinguisher to be used as case specific
S. No. Chemical Name Type of Extinguisher
1 Coke Use: Water fog, CO2, Foam, Dry Chemical
2 Fuel Oil Use: Water spray, foam, dry powder or carbon dioxide
Do Not Use: water jet as an extinguisher, as this will spread the fire
3 HSD Use: Foam, Carbon dioxide, Dry Chemical Powder. Water may be used to cool fire-
exposed containers
4 LDO Use: water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames
5 Fly Ash Non Flammable
6 Gypsum Non Flammable
7 Laterite Non Flammable
8 Metal dust Certified class D Extinguishing agent
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 179 JM EnviroNet Pvt. Ltd.
Table - 7.5
List of Extinguisher to be used as Site specific
S. No. Name of site Type of Extinguisher
1 Cable galleries CO2& Foam type, Dry chemical powder
2 High voltage panel CO2& Foam type, Dry chemical powder
3 Control rooms CO2& Foam type, Dry chemical powder
4 MCC rooms CO2& Foam type, Dry chemical powder
5 Pump Houses CO2& Foam type, Dry chemical powder
6 Guest houses and offices Dry chemical powder, Foam type
7 Godowns Foam type
8 Bunkers, Silo, enclosed dust
collector
CO2 type, N2 type, automatic sprinkler, fixed spray
nozzle(unless water reactive)
(iii) Evacuation Procedure
As the major hazard is only due to fire, which has more or less localized impact no mass
evacuation, procedures are required. Evacuation would involve only the people working very close
to the fire area.
(iv) First Aidand Dispensary (In House Facilities)
A well-equipped dispensary is available with Shree Cement Ltd., Ras with two full time doctors and
supporting paramedical staff. The dispensary operates round the clock and is equipped with four
indoor beds and other required facilities. First aid boxes are kept in the plant at various locations
where employees are using these facilities as and when they required.
(v) Safety
The safety wing led by a Safety officer will meet the requirement of emergencies round the clock.
The required safety appliances shall be distributed at different locations of the plant to meet any
eventualities. Poster/placards reflecting safety awareness will be placed at different locations in
the plant area.
(vi) Head Count
An up-to-date Daily Report of employees and contractor workers within the factory premises is
maintained by our Labor contract office / Time Office, which is located at the factory main gate.
Record of arrival and departure of visitors is also maintained by Security Dept. at the Gate Office.
In case of Emergency, these records will be helpful for counting the evacuated persons from
plant.
(vii) Emergency Training and Exercises
Drills and exercises constitute the second basic component of disaster management. They both
refer to a re-enactment, under the assumption of a mock scenario, of the implementation of the
response actions to be taken during an emergency. The emergency response plans and
emergency preparedness level would be tested through the following drills:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 180 JM EnviroNet Pvt. Ltd.
a. Table-top exercise (TTE)
b. Functional exercise (FE)
c. Full-scale exercise (FSE)
All elements/procedures of the On-Site Emergency Plan would be first tested through TTE and
perfected to the extent possible. The Plan then would be modified/ updated. Functional Exercises
basically to ensure proper functioning of various equipment such as the fire-fighting equipment
and the fire hydrant system. The Full-Scale Drill would be conducted to know the level of
preparedness of all teams. Initially, TTE and FE would be conducted periodically.
The following drills are conducted periodically:
a. Plant Emergency Drill for fire
b. Fire Drills at offices and admin building
c. Plant Emergency Drills (fire scenario involving evacuation)
vii) Personal Protective Equipments (PPEs)
Personal protective equipments play a vital role in overcoming major disastrous situation saving
life during onsite emergency. List of recommended Personal Protective equipment (PPE) is given
below in Table - 7.6.
Table - 7.6
Summary of Recommended Personal Protective Equipment according to hazard onsite
Objective Workplace Hazards Suggested PPE
Eye and face
protection
Flying particles, molten metal, liquid
chemicals, gases or vapors, light
radiation
Safety glasses with side-shields,
protective shades, etc.
Head protection Falling objects, inadequate height
clearance, and overhead power cords
Plastic helmets with top and side impact
protection
Hearing protection Noise, ultra-sound Hearing protectors (ear plugs or ear
muffs)
Foot protection Failing or rolling objects, points
objects. Corrosive or hot liquids
Safety shoes and boots for protection
against moving and failing objects, liquids
and chemicals
Hand protection Hazardous materials, cuts or
lacerations, vibrations, extreme
temperatures
Gloves made of rubber or synthetic
material (Neoprene), leather, steel,
insulation materials, etc.
Respiratory
protection
Dust, fogs, fumes, mists, gases,
smokes, vapors
Facemasks with appropriate filters for
dust removal and air purification
Body / leg protection Extreme temperatures, hazardous
materials, cutting and laceration
Insulating clothing, body suits, aprons etc.
of appropriate materials
Fly Ash Fly ash handling and storage Wear dust-proof goggles, dust mask and
rubber or PVC gloves.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 181 JM EnviroNet Pvt. Ltd.
Apart from this, all the employees are provided with helmets and safety shoes. It is statutory on
the part of the company employees to wear the appropriate safety gear given while attending
duty in the factory.
7.4.4.3 Off-Site Emergency Planning
The off-site emergency plan is an integral part of any hazard control system. It is based on those
accidents identified by the works management, which could affect people and the environment
outside the works. Thus, the off-site plan follows logically from the analysis that took place to
provide the basis for the on-site plan and the two plans therefore complement each other. The
roles of the various parties that may be involved in the implementation of an off-site plan are
described below. The responsibility for the off-site plan will be likely to rest either with the works
management or with the local authority.
Either way, the plan must identify an emergency coordinating officer who would take overall
command of the off-site activities. Consideration of evacuation may include the following factors:
In the case of a major fire but without explosion risk (e.g. an oil storage tank), only
houses close to the fire are likely to need evacuation
If fire is escalating very fast it is necessary to evacuate people nearby as soon as possible.
In acute emergency people are advised to stay indoors and shield themselves from the
fire.
Organization
Organizational details of command structure, warning systems, implementation procedures,
emergency control centres include name and appointments of incident controller, site main
controller, their deputies and other key personnel involved during emergency.
Communications
Identification of personnel involved, communication centre, call signs, network, list of telephone
numbers.
Special Emergency Equipment
Details of availability and location of heavy lifting gear, specified fire-fighting equipment, fireboats
etc.
Voluntary Organizations
Details of Voluntary organizations, telephone numbers nearby of hospitals, Emergency helpline,
resources etc are to be available with chief authorities.
Non-government Organizations (NGO)
NGO s could provide a valuable source of expertise and information to support emergency
response efforts. Members of NGOs could assist response personnel by performing specified
tasks, as planned during the emergency planning process.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 182 JM EnviroNet Pvt. Ltd.
Evacuation of personnel from the affected area
Arrangements at rallying posts and parking yards
Rehabilitation of evacuated persons
Chemical information
Details of the hazardous substances (MSDS information) and a summary of the risks associated
with them are to be made available at respective site.
Meteorological information
There is to be arrangements for obtaining details of weather conditions prevailing at r before the
time of accident and weather forecasts updates.
Humanitarian Arrangements
Transport, evacuation centres, emergency feeding, treatment of injured, first aid, ambulances,
temporary mortuaries.
Public Information
Dealing with the media-press office
Informing relatives, etc
Assessment
Collecting information on the causes of the emergency
Reviewing the efficiency and effectiveness of all aspects of the emergency plan.
Role of local authority
Local Authorities like Panchayat, Sabha, Samity, municipalities can help in combating emergency
situation after assessing the impact scenario in rescue phase.
Role of police
The police is to assist in controlling of the accident site, organizing evacuation and removing of
any seriously injured people to hospitals.
Co-ordination with the transport authorities, civil defence and home guards
Co-ordination with army, navy, air force and state fire services
Arrange for post mortem of dead bodies
Establish communication centre with easy contact with ECC.
Role of Fire Brigade
The fire brigade is to be organized to put out fires and provide assistance as required during
emergency.
Media
The media is to have ready and continuous access to designated officials with relevant
information, as well as to other sources in order to provide essential and accurate information
to public throughout the emergency and to avoid commotion and confusion.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 183 JM EnviroNet Pvt. Ltd.
Efforts are made to check the clarity and reliability of information as it becomes available, and
before it is communicated to public.
Public health authorities are consulted when issuing statements to the media concerning
health aspects of chemical accidents.
Members of the media are to facilitate response efforts by providing means for informing the
public with credible information about accidents involving hazardous substances.
Role of health care authorities
Hospitals and doctors must be ready to treat all type of injuries to causalities during
emergency
Co-ordinate the activities of Primary Health Centres and Municipal Dispensaries to ensure
required quantities of drugs and equipments
Securing assistance of medical and paramedical personnel from nearby hospitals/institutions.
Temporary mortuary and identification of dead bodies
7.4.5 Conclusion
It has concluded that there will be no major risk involved due to proposed project activity. Proper
precaution will be taken so risk can be minimized. Personal Protective Equipments (PPEs) will help
to minimize the health hazards and accidental casualties. So it is safe to say that there will be no
major risk involved due to the proposed expansion project.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 184 JM EnviroNet Pvt. Ltd.
CHAPTER-VIII
PROJECT BENEFITS
8.1 INTRODUCTION
M/s. Shree Cement Limited (SCL) believes holistic socioeconomic development of the local
community is the need of the hour. It truly believes that a company s prosperity is linked with that
of its neighboring communities. All the development related and community support activities are
driven at all cement manufacturing and grinding units and have continuous on-going social
interventions.
8.2 PROMOTION OF SOCIAL AND ECONOMIC STATUS
The beneficial aspects of the projects on the socio-economic environment of the area are in the
areas of employment, service, trade, commerce, public utility, literacy, social awareness, health
care facilities, recreation etc.
SCL will contribute substantially to the overall economy and social development of the area
through Enterprise Social Commitment (ESC) activities.
The operation zone of the ESC activities for the proposed expansion project will be extended to
the nearby villages of project site. The company will propose plans to supplement the existing
governmental programs among the local population. Environmental awareness will be created
among people by organizing awareness camps. Developmental activities will be carried out
keeping sustainable development in mind.
OUR VISION
Lead in creating Prosperity and Happiness for all stakeholders through Innovation and Sustainable
Practices
As an organization, SCL spread happiness amongst everyone connected with their eco-system and
create wealth for investors, employees, business associates and communities where SCL operate by
experimenting and implementing new ideas for improving efficiencies and maximizing the ratio of
output product to input resources.
Based on the needs assessment, the ESC programmes will be customized and implemented while
partnering with government agencies, NGOs, local Panchayats for implementation. 'Village
Development Committees' will be formed to engage with the community; plan, monitor and
coordinate the ESC activities. Major areas undertaken by SCL under ESC activities have been
shown below in Figure 8.1.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 185 JM EnviroNet Pvt. Ltd.
Figure 8.1: Major areas under ESC activities
8.3 ESC Activities Carried Out by Shree CementLtd.
Various activities carried out under ESC by SCL are as follows:
8.3.1 Primary Education Programmes
As part of Shree Samaj Sewa , SCL is running centres of Shree ki Pathshala (SKP) where
238 girl children are enrolled as on date. The programme covers 12 villages and caters for basic
primary education for girl children who have not been able to go to school
Bal Melas have been organized to attract children towards education and provide them a
platform to identify their skills and expertise in various villages
Umang Programme allows SKP Girls to get involved in diverse interests including importance
of education. It is important for them to be very diverse in their interests based upon locally
available resources for crafts, painting etc
A Computer Learning Centre at Village Babra, Butiwas and Ras has been set up under
Computer Literacy Programme. Around 475 students has been benefitted so far in these
centres. These Computer learning centres keep them updated with the latest technologies
SCL has constructed a new Primary School at villages Chapar Ki Dahni, Ras
SCL provides scholarships to ITI students, so that they can persue technical course and can be
gainfully employed
SCL has adopted various schools in the region. SCL promotes quality education in the area
distribution of educational materials to children was done in Government schools. Students
were provided with Study materials like exercise books, drawing book, pen, colour pencil,
geometry box and water bottles
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 186 JM EnviroNet Pvt. Ltd.
Details of School Adoption Programme by SCL
S.
No.School Village Works Undertaken/ Material Provided
1. Government Upper
Primary School
Bagatpura - 50 Sets of Stool and Table
- 15 Visiting Chairs
- 1 office Table
- 1 Podium
- 110 Steel plates
2. Govt. Upper Primary
Sanskrit School
Khera - 30 Sets of Stool and Table
- Fitting of Doors and Windows in Classrooms
3. Govt. Upper Primary
School
Bhimgarh - 60 Stools and 30 Tables
- 3 fans and 5 Tube Lights,
- Electric Wiring Fittings,
- One Computer Set with Printer
- 3 Carpets (Dari)
4. Govt. Primary School Jagtiya - Upliftment of School Boundary wall
- Electric wiring Fittings
5. Govt. Primary School Jawangarh - Repairing of Roof and veranda
- Repairing of Toilet
6. Govt. Upper Primary
School
Nimbeti - 40 Sets of Stools and Table
- One Computer Set with Printer
- 2 Almirah
- 4 Visiting Chairs
7. Govt. Girls Secondary
School
Babra - 50 Sets of Stools and Table
- Construction of Girls Toilets,
- 1 office chair
- 1 Office Table
- 5 Visiting chairs
8. Govt. Senior Secondary
School
Kolpura - 100 Sets of Stools and Table
- 2 Set of office Table and Chairs
- 1 Carpet (Dari)
- Cleaning of School Premises
9. Govt. Boys Upper
Primary School
Babra - Construction of Veranda
- Fitting of Tin Shed
10. Govt. Senior Secondary
School
Ras - Upliftment of School Boundary Wall
- 2 Carpet (Dari)
Details of School Support Programme by SCL
S.No. Panchayat Village Name of the School No. of Students Benefitted
1. Pratapgarh Pratapgarh Government Secondary School 320
2. Pratapgarh Naharpura Government Upper Primary School 282
Total 602
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 187 JM EnviroNet Pvt. Ltd.
Shree ki PathshalaBal Mela
Computer Literacy Programme UmangProgramme
Computer and Printer provided to School Construction of School Building for New Primary School
School Support Programme ITI scholarship programme
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 188 JM EnviroNet Pvt. Ltd.
8.3.2 Promoting Gender Equality and Women Empowerment Programmes
Eight Self Help Groups (SHGs) which will help in inculcating a habit of saving and create corpus to
undertake entrepreneur assignments under Shree Shakti Project.
SCL has carried out income generation Programme for girls.
SCL provides basic required items for marriage of Girls from BPL families who got married after
attaining the age of 18 years. The materials like Stainless Steel Utensil Set, Sewing Machine, Dress
for Bride and Bride Groom, GI Box (peti), Iron, Bedding Set, Cooking Stove and Cooker are being
present to the Bride.
SCL has started the program named Baalika Bachao Aandolan to reduce the infant mortality and
improving the Girl Child Sex Ratio (C.S.R) in the operational area of S.C.L Ras. Support of Rs. 5000
as Fixed Deposit for 18 years is being provided to the Girl Child of BPL families. The amount can be
withdrawn by the girl parents only after the completion of 18 years of age, which can be utilized
for providing Higher Education / Marriage.
Training and Exposure of SHG Members Practice session of the SHG Members
Support to BPL Families on Marriage Programme Save the Girl Child Campaign
8.3.3 Agriculture Development programmes
SCL has taken various initiatives for agricultural development like Exposure visits of farmers,
Agriculture training, distribution of agriculture seeds and fertilisers, providing subsidy for
agriculture equipment etc.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 189 JM EnviroNet Pvt. Ltd.
Exposure Visits of Farmers: SCL is promoting new agriculture techniques and creating knowledge
base of the farmers by exposure visits and trainings. During the last six months SCL organized
exposure visits to Krishi Vigyan Kendra, Ajmer to improve knowledge base of farmers on new
Horticulture and agricultural techniques like Green House scheme for nursery development, Fruit
plant scheme, Farm Pond scheme to develop a farm pond at fields, Solar energy scheme and
Onion storage schemes.
Agriculture Training: Farmers' training is provided at the local level by classroom and practical
demonstrations through SCL s internal faculty as well as with the support of Govt s Subject Matter
Specialist (SMS)
Subsidy for Agriculture Equipment: SCL has helped 47 farmers from SCL s operational villages
under Agricultural Equipment Programme Agricultural department, Government of Rajasthan
by provision of Sprinkler Set, HDPE Pipe and sprayers for adopting the modernized farming
techniques.
Distribution of Agriculture Seeds and Fertilizer: To increase the agriculture production SCL
facilitated provision of improved / hybrid seeds and fertilizers to 26 farmers through Department
of Agriculture
Exposure Visits of Farmers Agriculture Training
Distribution of Agriculture Seeds and Fertilizer Distribution of Agriculture Seeds and Fertilizer
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 190 JM EnviroNet Pvt. Ltd.
8.3.4 Reducing Child Mortality and Improving Health
Rural Health camps: To provide medical services and improve the health status of the villagers
Rural Medical Camps are organized in the adopted villages, three days in a month, in which
about 50 patients are treated in each camp by the expert medical team of Shree Cement
Limited.
Promotion of Institutional Delivery: For improvement of Institutional Delivery system we have
appointed 10 Sakhis (Rural Health Volunteer) at Village level. Sakhis (local women) act as
health educators and promoters in their communities
Shree Swashthya Vahini - Mobile Ambulance Service: In order to make delivery of the health
care services easy and convenient for the villagers SCL have started Shree Swashthya Vahini-
Mobile Ambulance
24 Hours Transport Facility for Delivery cases: Under Shree Samaj Sewa SCL provide 24 Hours
Ambulance Services on critical delivery cases in the Periphery villages of our Ras Plant
PHC/CHC/Sub Centre Adoption Programme: PHC/CHC/Sub Centre Adoption Programme: Shree
Cement, Ras has taken an initiative to adopt 2 PHCs and 1 Sub centre of nearby Panchayats for
three years under the public private partnership (PPP) Scheme.
Shree Chetna Project: To contribute in the Child Development scheme under Shree Chetna SCL
have adopted 11 Anganwadi centres nearby plant area in collaboration with the Women and
Child Development Department GoR.
Rural Health camps Fully Equipped Sub-Centre Bagatpura
ECG Machine for PHC Giri Ras II Anganwadi Bagatpura
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 191 JM EnviroNet Pvt. Ltd.
8.3.5 Ensuring Environment Sustainability
Repair / Deepening of Anicuts/ Nadi:
SCL is doing various projects like Repair/ Deepening of Anicuts/ Nadi, distribution of saplings
etc. to ensure Environment Sustainability.
Distribution of Saplings: Saplings of Ber, Nimbu, Avla and shadow tree have been distributed
amongst 291 farmers for mass tree plantation in villages to cover the open areas.
Orchard Development: Its purpose is to help local farmers in enhancing orchards. The project
focuses on setting up and running orchard, giving practical advice on day-to-day
management. In order to promote the development of Orchards, subsidy was provided to Sh.
Arjun son of Mala, Bhimgarh Village.
Repair work of Anicut
Orchard Development
8.3.6 Social Business Projects
SCL has done various Commumity development projects in the surrounding regions such as:
Construction of Water Storage Tank
Construction of Kheli (Open Water Storage Tank for Drinking Purpose of Animals)
Construction/ Renovation of Hatayi Shed
Support for Gaushala Development Work
Construction of Village Roads(Babra, Naya Gaon, Bhimgarh, Bagatpura, DungatokaBadia,
Butiwas)
Construction of Community Centre
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 192 JM EnviroNet Pvt. Ltd.
Construction of Water Storage Tank Construction of Kheli
Gaushala at Butiwas Before Gaushala at Butiwas After
Interlock Blocks at Temple Construction of New Community Hall, Shyampura
Support of cement and materials for different religious activities: As per request from the
villagers SCL have provided cement bags support for various religious places, Details are as
follow:
S. No. Activity Number of Bags
1 GoshalaGiri 150
2 Repairing work at Vishkarma Temple and Biratiya Khurd 175
3 Support for the development work at Shyam Mandir at Ramgarh 80
4 Development work at Ramdev Temple, Babra 100
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 193 JM EnviroNet Pvt. Ltd.
Installation of Safety Sign Boards: SCL Ras under Shree Samaj activities has taken the major
step of installing the Safey Sign Boards along the road side which will reduce the hazard, road
accidents. 183 Sign Boards were installed in the key areas from Beawar to Ras.
Contribution for Religious Festivals, Melas, Social Groups and Samitis: In order to encourage
cultural, social and religious activities, SCL has provided support for following 10 Melas in
which nearly 50,000 people participate.
8.3.7 Employment Enhancing Vocational Skills
Vocational training on Household Fittings and Appliances: One-month training on electrical
wiring and repairing of household gadgets like cooler, fan, press, mixer etc was conducted for
25 youths of the region.
Vocational Training Programme on Mobile Repairing: Thirty percent of the population is using
mobile phones in their everyday life. Day by Day the number is increasing and there is a lot
more demand for repairs and service work in rural areas. SCL conducted mobile repairing
training for 25 youth from our operational villages.
Vocational training on Household Fittings and Appliances Mobile Repairing Training
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 194 JM EnviroNet Pvt. Ltd.
Expenditure on ESC activities incurred during last Five years
Expenditure on ESC activities incurred during last Five years by SCL is given in Table - 8.1.
Table - 8.1
Expenditures incurred on CSR Activities
S.
No.Particulars 2011-12 2012 -13 2013-14 2014-15 2015-16
1.Health & family Welfare
Programmes455654 4426061 3189560 4596865 2527490
2.Education Promotion
Programmes2930666 1449689 3564161 8340810 6340000
3.Women Empowerment &
development Programme77780 145156 715510 3072599 1212485
4.Contribution in Religious & Social
Programmes5019430 713168 683927 - -
5.Community Infrastructure
development projects6710424 9182280 4313708 14821824 34116692
6. Agriculture & land development 40550 223728 3823012 3284971 742647
7.Training and capacity building
programme36857 10200 - 5319134 388100
8. Sponsorship, sports etc. - 3567129 5022223 1279000 47167
9. Drinking water Projects - 139897 - 4412652 775331
11.Natural Resource management &
water shed development446953 509475 525215 - -
Total 15718314 20366783 21837315 45128855 46149912
Table - 8.2
Proposed Expenditure on CSR activities
S.
No.Activity Heads
YEARS (Rs. in Lacs) Total Amt.
(Rs. in Lacs)1st 2nd 3rd 4th 5th 6th to 10th
1.Health & Family Welfare
Programmes10.0 12.0 16.0 18.5 24.0 120.0 200.5
2.Education Promotion
Programmes7.0 10.0 11.0 14.0 17.0 85.0 144.0
3.Women Empowerment and
Development Programme7.0 9.0 12.0 14.0 18.0 90.0 150.0
4.Contribution in Religious
andSocial Programmes4.0 5.0 8.0 9.0 10.0 50.0 86.0
5.Community Infrastructure
Development Projects74.0 106.0 108.0 143.0 146.0 730.0 1307.0
GRAND TOTAL
(@2.5% of Total Project Cost)102.0 142.0 155.0 198.5 215.0 1075.0 1887.5
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 195 JM EnviroNet Pvt. Ltd.
Table - 8.3
Detailed Activity-wise Action Plan for ESC Activities
(Rs. in Lacs)
S.
No.Major Projects
1st
Year2ndYear
3rd
Year
4th
Year5thYear 6th to 10thYear
Total
AmountESC Activities
Health and Family Welfare Programmes
1.Shree Mamta Sanklap (MCH) Health check camp for
Ante anatal mother and children up to one yr of age)5.00 5.00 7.00 7.00 10.00 50.00 84.00
To provide Nutrition supplement, health checkup
facility & maintain all data of target group.
2.Health awareness programme on drug de addiction,
sanitation,1.00 1.50 2.00 2.50 4.00 20.00 31.00
To sensitize the community about Govt. Schemes
for MCH, vaccination, safe delivery etc.
3.Immunization programme for children not covered in
Govt. RI programme for Hepatitis B, MMR Etc.2.00 3.00 4.00 5.00 5.00 25.00 44.00 Hepatitis B, MMR, ETC.
4.Chikitsa Apke Dwar Visits of Mobile unit to nearby
village & Distribution of Medicines2.00 2.50 3.00 4.00 5.00 25.00 41.50
Checkup of patients Medical advice and distribution
of medicines
5. School Health camp 10.00 12 16 18.5 24 120.00 200.50 General health checkup , distribution of eatables
Sub - Total 10.00 12 16 18.5 24 120.00 200.50
Education Promotion Programmes
1.Shree ka Hath Shiksha main ApkaSath
Scholarship, books, uniform to merit holder children5.00 7.00 7.00 9.00 10.00 50.00 88.00 To provide education material support to students.
2. Financial support to sports tournament 2.00 3.00 4.00 5.00 7 35.00 56.00
Sub - Total 7 10 11 14 17 85 144.00
Women Empowerment and Development Programme
1.Formation of Self Health Group (SHG) including
documentation5 5 7 7 10 50.00 84.00
2. Income Generation programmes 2 4 5 7 8 40.00 66.00Awareness project for women about health &
hygiene, education, women rights & Govt. Schemes
Sub - Total 7 9 12 14 18 90 150.00
Contribution in Religious & Social Programmes
1.Contribution in religious festivals, Melas e.g. Local
fares and sports activities2 3 4 5 5 25.00 44.00 Within all nearby village as per prevailing practices
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW), Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 196 JM EnviroNet Pvt. Ltd.
S.
No.Major Projects
1st
Year2ndYear
3rd
Year
4th
Year5thYear 6th to 10thYear
Total
AmountESC Activities
2.
Contribution for various programmes which
organized by other social groups &samitis such as
Mass Marriages etc.
2 2 4 4 5 25.00 42.00Financial assistance to external agencies for
organizing such events
Sub - Total 4 5 8 9 10 50 86.00
Community Infrastructure Development Projects
1. Development of community center 10 12 12 15 15 75.00 139.00To provide permanent structure for organizing
community development programmes
2. Drinking Water 5 7 7 10 11 55.00 95.00 Drinking water arrangement for local area.
3. Construction of CC roads, drainage & water tanks etc. 50 75 75 100 100 500.00 900.00
4. Rebate on cement for local works 4 5 7 8 10 50.00 84.00
5. Providing School Infrastructure 5 7 7 10 10 50.00 89.00Additional rooms, furniture, playground, toilets, and
computer lab. etc.
Sub - Total 74 106 108 143 146 730 1307.00
Grand Total 102.0 142.0 155.0 198.5 215.0 1075.0 1887.5
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - VIII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 197 JM EnviroNet Pvt. Ltd.
8.4 CONCLUSION
Shree Cement Plant at Pali (Raj.) has generated a fair amount of direct and indirect employment in
the study region. The local economy has received a boost due to employee spending and services
generated by the company. The overall effect has improved the buying power of employees and
thus a higher standard of living viz. better education, improved health and sanitation facilities,
housing etc. This is envisaged as a major positive benefit, which ultimately lead to the sustainable
development of the region.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - IXof Final EIA / EMP Report
M/s. Shree Cement Ltd. 198 JM EnviroNet Pvt. Ltd.
CHAPTER - IX
ENVIRONMENTAL COST BENEFIT ANALYSIS
9.1 ENVIRONMENTAL COST BENEFIT ANALYSIS
As per EIA Notification dated 14th Sept., 2006, as amended from time to time; the Chapter on
Environmental Cost Benefit Analysis is applicable only, if the same is recommended at the
Scoping stage.
As per the ToR points issued by MoEFCC, New Delhi vide letter no. J-11011/343/2012-IA II (I) dated
10th Feb., 2016 for the proposed expansion project, the Environmental Cost Benefit Analysis is not
required.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 199 JM EnviroNet Pvt. Ltd.
CHAPTER-X
ENVIRONMENTAL MANAGEMENT PLAN
10.1 INTRODUCTION
Shree Cement Limited (SCL) is committed to comprehensive Environment Management Plan for
environmental protection and conservation in proposed expansion of Integrated Cement Plant at
Village: Ras, Tehsil: Jaitaran, District: Pali(Rajasthan). SCL is already implementing a well laid
Environmental Management Plan at SCL, Ras.
Based on the evaluation of impacts and baseline conditions, an Environmental Management Plan
(EMP) has been delineated to mitigate the adverse impacts of proposed expansion project on
environment of the area.
The environmental management plan consists of the set of waste minimization, impact mitigation,
management, monitoring and institutional measures to be taken during implementation and
operation to eliminate the adverse environmental impacts or reduce them to acceptable levels.
The present environmental management plan addresses the components of environment
affected during construction of the plant and by different operations in a Cement Plant.
The EMP is herein outlined after taking into account the various Acts, Rules and Regulations /
Standards concerned with the environmental management.
Aims of EMP:
Overall conservation of the environment
Minimization of waste generation and pollution
Judicious use of natural resources and water
Safety, welfare and good health of the work force
Ensure effective operation of all control measures
Vigilance against probable disasters and accidents
Monitoring of cumulative and longtime impacts
Environmental Management Plan is detailed under the following heads:
Air Quality Management
Noise Management
Waste Water Management
Solid and Hazardous Waste Management
Energy Conservation
Greenbelt Development and Plantation Programme
Occupational Health and Safety Measures
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 200 JM EnviroNet Pvt. Ltd.
10.2 AIR QUALITY MANAGEMENT
The major pollutants of air in a cement plant are the suspended particulate matters from the
various stacks and fugitive emissions due to material handling.
10.2.1 Stack Emissions and Control Technologies
A stack is a type of chimney, a vertical pipe, channel or similar structure through which
combustion product gases called flue gases are emitted to the outside air.
To keep the PM emissions from stack below permissible limits, all major sources of air pollution
(i.e. kiln, cooler, cement mill etc.) will be provided with RABH / Bag filters / ESP. List of air
pollution control equipments is given in Table - 10.1 and Emission Details are given in Table - 10.2.
Table - 10.1
List of Air Pollution Control Equipments
S.
No.Locations
Control Equipment Efficiency
Existing Proposed 99.9 %
1. Raw Mill and Kiln Bag House and ESP Bag House 99.9 %
2. Coal Mill Bag House Bag House 99.9 %
3. Clinker Cooler ESP ESP 99.9 %
4. Cement Mill Bag House Bag House 99.9 %
5.Captive Power
PlantESP Nil
99.9 %
6.
Mixer and Den of
Synthetic Gypsum
unit
Wet Scrubber Nil 99.9 %
Photographs of existing air pollution control equipments are shown in Figure - 10.1.
Raw Mill & Kiln RABH Coal Mill Bag House
Clinker Cooler ESP
Figure 10.1: Existing Air Pollution Control Equipments
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 201 JM EnviroNet Pvt. Ltd.
Table - 10.2
Emission Details
Stack attached toStack
no.
Height from
ground level (m)
Internal Diameter
(Top)(m)
Emission Rate (kg/hr.)
PM SO2 NO2
Raw Mill and Kiln-3 &4
Common Stack1 112 5.6 20.22 97.74 539.10
Coal Mill-3 1 110 1.4 2.34 NA NA
Clinker Cooler-3 1 55 4.01 8.16 NA NA
Cement Mill-3 1 45 1.46 1.58 NA NA
Coal Mill-4 1 110 1.4 2.34 NA NA
Clinker Cooler-4 1 55 4.01 8.16 NA NA
Cement Mill-4 1 45 1.63 1.50 NA NA
Raw Mill and Kiln-5 1 112 3.8 10.11 48.87 269.55
Coal Mill-5 1 110 1.4 2.22 NA NA
Clinker Cooler-5 1 55 4.01 8.16 NA NA
Raw Mill & Kiln-6 1 112 3.8 11.23 54.30 299.50
Coal Mill-6 1 110 1.4 2.34 NA NA
Clinker Cooler-6 1 55 4.01 6.53 NA NA
Raw Mill and Kiln-7 1 112 3.8 11.23 54.30 299.50
Coal Mill-7 1 110 1.4 2.34 NA NA
Clinker Cooler-7 1 55 4.01 6.53 NA NA
Raw Mill and Kiln-8 1 112 3.8 11.23 54.30 299.50
Coal Mill-8 1 110 1.4 2.34 NA NA
Clinker Cooler-8 1 55 4.01 6.53 NA NA
Raw Mill and Kiln-9 1 150 5 23.53 146.61 627.37
Coal Mill-9 1 63 2 4.21 NA NA
Clinker Cooler-9 1 60 4.3 13.05 NA NA
Raw Mill and Kiln-10 1 150 5 23.53 146.61 627.37
Coal Mill-10 1 63 2 4.21 NA NA
Clinker Cooler-10 1 60 4.3 13.05 NA NA
RNCU VRM 1 50 4 11.72 NA NA
RNCU Ball Mill 1 27 1.63 1.60 NA NA
Synthetic Gypsum (scrubber) 1 50 1.8 2.11 NA NA
Boiler 3 1 92 2.3 6.09 73.14 36.57
Boiler 4 and 5 1 105 3.15 6.36 76.35 38.17
Boiler 7 and 8 1 115 3.2 6.36 76.35 38.17
Boiler 9 and 10 1 95 3.2 6.09 73.14 36.57
10.2.2 Fugitive Emissions, Sources and Control Technologies
10.2.2.1 Fugitive Emissions
Fugitive emissions are the air pollutants released in the air other than those from stacks or vents.
Fugitive dust may be defined as any solid particulate matter that becomes airborne by natural or
man-made activities, excluding particulate matter emitted from an exhaust stack .
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 202 JM EnviroNet Pvt. Ltd.
Factors that influence emissions
Factors affecting emissions that are common to most operations include the following:
Moisture content of the material
Type of material processed
Type of equipment
Operating practices employed
10.2.2.2 Sources of Fugitive Emissions in Cement Plant and Mitigation Measures
Storage of Raw Materialsand Finished Product
Dust may be generated here due to carryover by wind. However, to avoid this, clinker will be
stored in clinker silos; fly ash will be stored in silos and gypsum in covered yard.Details reg.
storage facilities for raw material and product are given in Table - 10.3 and photographs are shown
in Figure - 10.2.
Table - 10.3
Storage Facilities
S.
No.Type of Materials
Type of Storage Capacity (Tonnes)
Existing Proposed Existing Proposed
1. Limestone Stock pile Stockpile 540000 240000
2. ClinkerStockpile /
Silo
Stockpile /
Silo300000 75000
3.Indian and Imported Coal,
Pet Coke & LigniteCovered Dome Silo Covered Dome Silo 550000 200000
4. Cement Silo Silo 35000 4x7500
5.Gypsum (Mineral, Synthetic,
Chemical & Imported)Covered Yard Covered Yard 15000 20000
6. Fly ash Silo Silo 10500 2x5000
7.Laterite/ Lead Zinc Slag/iron
oreStockpile Stockpile 50000 3000
Source: Pre-feasibility Report
Raw Meal Silo Cement Silo
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 203 JM EnviroNet Pvt. Ltd.
Clinker Silo
Coal and Pet Coke Storage Dome Silo Pond ash and Gypsum Storage Shed
Figure 10.2: Existing Storage Facilities
Transportation
Transportation of clinker to the clinker silo will be done through covered conveyor belt in a very
controlled manner; while that of the fly ash to fly ash silo will be done pneumatically from tankers.
This will help in reducing the fugitive emissions. Movement of heavy trucks/vehicles on the non-
metallic road generates substantial quantity of dust emission. This is due to the presence of dust
over the road, which is carried away by wind.
To control the generation of dust, all the roads inside the plant premises are / will be concreted.
Regular sweeping of all the roads and floors is/will be done by vacuum sweeping machine.
Sprinkling of water through tankers is/will be done on bare lands and roads.
Material Transfer
Dust is/will be generated from all the transfer points of belt conveyors. This is/will be controlled by
spraying water at unloading points and providing bag filters at all transfer points. 16 nos of bag
filters for clinker Unit XI and 34 nos of bag filters are proposed to be established for new Cement
mill. The details of the Bag Filters are given in table below:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 203 JM EnviroNet Pvt. Ltd.
Clinker Silo
Coal and Pet Coke Storage Dome Silo Pond ash and Gypsum Storage Shed
Figure 10.2: Existing Storage Facilities
Transportation
Transportation of clinker to the clinker silo will be done through covered conveyor belt in a very
controlled manner; while that of the fly ash to fly ash silo will be done pneumatically from tankers.
This will help in reducing the fugitive emissions. Movement of heavy trucks/vehicles on the non-
metallic road generates substantial quantity of dust emission. This is due to the presence of dust
over the road, which is carried away by wind.
To control the generation of dust, all the roads inside the plant premises are / will be concreted.
Regular sweeping of all the roads and floors is/will be done by vacuum sweeping machine.
Sprinkling of water through tankers is/will be done on bare lands and roads.
Material Transfer
Dust is/will be generated from all the transfer points of belt conveyors. This is/will be controlled by
spraying water at unloading points and providing bag filters at all transfer points. 16 nos of bag
filters for clinker Unit XI and 34 nos of bag filters are proposed to be established for new Cement
mill. The details of the Bag Filters are given in table below:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 203 JM EnviroNet Pvt. Ltd.
Clinker Silo
Coal and Pet Coke Storage Dome Silo Pond ash and Gypsum Storage Shed
Figure 10.2: Existing Storage Facilities
Transportation
Transportation of clinker to the clinker silo will be done through covered conveyor belt in a very
controlled manner; while that of the fly ash to fly ash silo will be done pneumatically from tankers.
This will help in reducing the fugitive emissions. Movement of heavy trucks/vehicles on the non-
metallic road generates substantial quantity of dust emission. This is due to the presence of dust
over the road, which is carried away by wind.
To control the generation of dust, all the roads inside the plant premises are / will be concreted.
Regular sweeping of all the roads and floors is/will be done by vacuum sweeping machine.
Sprinkling of water through tankers is/will be done on bare lands and roads.
Material Transfer
Dust is/will be generated from all the transfer points of belt conveyors. This is/will be controlled by
spraying water at unloading points and providing bag filters at all transfer points. 16 nos of bag
filters for clinker Unit XI and 34 nos of bag filters are proposed to be established for new Cement
mill. The details of the Bag Filters are given in table below:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 204 JM EnviroNet Pvt. Ltd.
Details of Bag Filters for Control of Fugitive Emission for Clinker Unit XI
Sr.
NoApplication Location Material
Qty. of supply
in one set(No)
Gas temp.
(Deg.C)
Revised Gas
volume
(m3/hr)
1 Lime Stone CrusherNear Crusher discharge
belt head pulleyLimestone dust 1 50 10000
2 Vibrating Screen At Screen house Limestone dust 1 50 20000
3 Raw Mill Hoppers topOn top of raw material &
additive hoppersLimestone dust 1 50 15000
4 Raw Mill TransportTransfer tower of raw
material beltsLimestone dust 1 50 10000
5Raw mill reject
recirculation
Near Raw mill reject
elevatorLimestone dust 1 100 max. 10000
6 Raw Meal TransportBetween cyclones to RM
Silo above air slidesLimestone dust 1 100 max. 15000
7 Raw Meal Silo TopOn the top of raw meal
siloLimestone dust 1 100 max. 15000
8Raw mill Silo
extraction
On air slides at silo
extractionLimestone dust 1 100 max. 7500
9 Kiln Feed Bin Pre heater first floor Limestone dust 1 100 max. 15000
10 Preheater Top Pre heater top floor Limestone dust 1 100 max. 15000
11 Raw Coal HopperAbove coal hoppers at
the belt discharge.Coal dust 1 50 15000
12 Fine Coal HopperOn the floor below coal
mill main bag houseCoal dust 1 50 7500
13 Clinker TransportOn transfer tower of
clinker belts.Clinker Dust 2 100 10000
14 Clinker Tank Top At the discharge of DPC Clinker Dust 1 100 35000
15
Clinker Hopper /
Clinker Bulk Loading
Hopper
On the top of hoppers
for truck loading points.Clinker Dust 1 100 15000
Total 16
Details of Bag Filters for Control of Fugitive Emission for Cement Mill
S. No. Bag Filter Location Quantity Capacity
1. Bag filter with fan at Bucket elevator 1 7500 m3/hr
2. Bag filter with fan above clinker tank 1 35000 m3/hr
3. Bag filter with fan at clinker tank outlet belts, 2 Nos. 2 10000 m3/hr
4. Bag Filter with fan at TT2 1 3000 m3/hr
5. Bag filter with fan for reject circuit(elevator) 1 15000 m3/hr
6. Bag filter with fan for reject circuit 1 7500 m3/hr
7. Bag filter with fan for product transport air slide, 2 Nos 1 10000 m3/hr
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 205 JM EnviroNet Pvt. Ltd.
S. No. Bag Filter Location Quantity Capacity
8. Bag filters with fan for Dry Fly ash dump hopper de-dusting 2 50000 m3/hr
9. Bag filters with fan for Gypsum dump hopper de-dusting 1 20000 m3/hr
10. Bag filter at FA Silo top 1 15000 m3/hr
11. Bag filter for fly ash Air Slide Extraction feeding to Mill 1 3000 m3/hr
12. Bag filter for collecting bin (fly ash silo) 1 7500 m3/hr
13. Bag filter at Cement Silo top (1+1) 2 7500 m3/hr
14. Bag filter for air slides & packing plant elevator boot 3 10000 m3/hr
15. Bag filters for Roto packer Dedusting -3 no's 3 40000 m3/hr
16. Bag filters for Roto packer Dedusting -3 no's 3 20000 m3/hr
17. Bag filter above clinker hopper 1 15000 m3/hr
18. Bag Filter for Air slides below bag house 1 10000 m3/hr
19. Bag Filter for Dedusting at Belt Conveyor Below weigh feeders 1 20000 m3/hr
20. Bag filter for above elevator & air slide venting 1 15000 m3/hr
21. Bag filter for venting of product air slide 1 15000 m3/hr
22. Bag filter for venting of mill outlet elevator & air slide 1 10000 m3/hr
23.Bag filter for venting for transport auxiliaries & elevator venting in
Cement mill section1 20000 m3/hr
24. Cement mill venting (Ball Mill) Bag house 1 65000 m3/hr
25. VRM venting Pulse Jet Bag house 1 480000 m3/hr
Total 34
As per CPCB Guidelines following measures are /will be implemented in the Cement Plant to
control the generation of fugitive emissions:
Enclosures are/will be provided for unloading operations
Water is/will be sprayed during unloading of materials
Bag filters are/will be installed at all transfer points to reduce fugitive dust emissions.
Atomized water spraying system is/will be provided on raw material unloading hoppers.
Water Spray on roads & other areas by Mobile tanker/water sprinklers.
All the Roads inside the plant premises are/will be concreted.
Regular sweeping of all the roads & floors is/will be done.
Dust collected from air pollution control equipment is/will be totally recycled in the process.
Fly ash is/will be pumped directly from the tankers to silos pneumatically in closed loop or
mechanically such that fugitive emissions do not occur.
Dry fly ash is/will be transported into closed system.
The packing machine is/will be equipped with dust extraction arrangement. Dust is/will be
captured in bag filters.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 206 JM EnviroNet Pvt. Ltd.
Other Measures Implemented in the Cement Plant to Reduce the Dust Emission
Maintenance of Bag Houses and ESPs
Maintenance of the Bag houses includes replacement of bags, checking the performance of the Bag
House, maintenance of ID fans etc.
The information on performance of Bag Houses and ESPs in relation to the process/ production a
condition is/will be collected to optimize the efficiency of Bag Houses and ESPs.
All the bag filters and bag houses in the project are/will be designed for higher loads and gas flow,
which can meet the proposed enhancement in production.
Sources of Emissions in the Cement Plant
For achieving effective prevention and control of potential fugitive emission sources in cement
manufacturing plants, specific requirements along with guidelines have been given by CPCB, which
is/will be followed specifically in the project operation. Regular inspection is/will be carried out for all
fugitive control system and records are/will be maintained as per CPCB guidelines.
For the purpose of effective prevention and control of fugitive emissions, regular monitoring is/will be
done and also, following measures are/will be taken as per the guidelines:
1. Unloading Section (Limestone, Coal &Other Relevant Material)
S. No. Guidelines Control Measures provided/to be Provided
1. The enclosures for the unloading sides could be flexible
curtain type material covering up to height of dumpers
discharge from the roof.
Enclosures are/will be provided for all
unloading operations, except wet materials
like gypsum.
2. A dust suppression system should be provided to spray
water. The amount of water sprayed should preferably be
optimized by employing proper design of spray system.
Suitable systems may be adopted to reduce the problems
like choking, jamming of the moving parts.
Water is/will be sprayed on the material
prior and during unloading.
2. Material Handling Section (Including Transfer Points)
S. No. Guidelines Control Measures provided/to be Provided
1. The enclosures from all sides with the provision for access
doors, which shall be kept, closed during operation.
Spillages should be periodically removed.
Transfer point locations are/will be fully
enclosed.
2. Either water spray system should be provided for
suppressing the air borne dust or dry extraction cum bag
filter with adequate extraction volume should be
installed.
Air borne dusts at all transfer locations /
points are/will be controlled either by
spraying water or by extracting to bag filter.
3. Spray sufficient quantity of water to moist the top layer
to avoid wind blowing of fine particles.
Water is/will be periodically sprayed on the
stockpiles so as to retain some moisture in
the top layer.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 207 JM EnviroNet Pvt. Ltd.
3. Coal Storage Section
S. No. Guidelines Control Measures provided/to be Provided
1. A board should be erected to display the area earmarked. Coal yard/storage area is/will be clearly
earmarked on the Board.
2. Proper pathways with entry and exit point should be
provided.
The pathways in coal yard for vehicle
movement is/will be paved.
3. Any deposits of dust on the concrete roads should be
cleaned regularly by sweeping machines.
Accumulated dust is/will be removed
/ swept regularly and the area is/will be
watered after sweeping.
4. Wherever blending activity is carried out by chaining in
open ground, covered shed should be provided to reduce
the fine coal dust getting airborne. The enclosure walls
shall cover minimum three sides up to roof level.
Coal other than coal stockpile is/will be
preferably stored under covered shed.
5. The enclosure should be from three sides and roof so as
to contain the airborne emissions.
The coal stock pile is/would preferably be
under covered shed.
6. Instead of dust extraction cum bag filter system, if dust suppression measure is used, following
additional control measures should be provided.
a. Coal should be sufficiently moistened to suppress fines by
spraying minimum quantity of water, if possible.
Wetting before unloading.
b. Water spray should also be applied at crusher discharge
and transfer points.
Spray water at crusher discharge and
transfer points.
4. Clinker Cooler Section
S. No. Guidelines Control Measures provided/to be Provided
1. The possibilities especially in new cement plant may be
explored for the following:
The unit may need to add on / install necessary provisions
for separating fine particulates from the clinker cooler
ESP collection. Fines separation may be achieved by
passing collected dust through cyclone, the fines
escaping cyclone to be separated, cyclone collection
(coarse particles) could be recycled. The fines shall be
recycled to the last possible destination (like clinker day
silo) suitable or safely disposed.
Air borne fines extracted from clinker cooler
is/will be separated and recycled.
ESP is/will be provided at clinker cooler.
5. Clinker Stock Piles Section
S. No. Guidelines Control Measures provided/to be Provided
1. Bag filter may be provided before venting out the gases. The same is/will be done at plant unit.
2. The enclosures should have a venting Clinker is/will be stored in stockpile/ silo
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 208 JM EnviroNet Pvt. Ltd.
S. No. Guidelines Control Measures provided/to be Provided
arrangement located at transfer point where clinker is
dropped to the stockpile. The extraction /venting should
be sufficient enough. Clinker stockpile access door should
be covered by mechanical gate or by flexible rubber
curtain. The access doors shall be kept closed at all
possible times.
which have a venting arrangement along
with a bag filter.
3. Extracted dust should be captured in bag filter and the
collected dust should be avoided to feed back to the
clinker stockpile, if layout permits. It may be recycled at
last possible destination i.e., cement mill section through
suitable arrangement, if possible.
The dust extracted and captured in bag filter
is/will be avoided to feed back/recycled to
the clinker stockpile, if possible.
4. Generally open storage of clinker should be avoided. Only in case of emergency clinker would be stored
in open with following control measures.
a After earmarking the open storage area of clinker, a
board should be erected to display the area earmarked.
Area for open storage of clinker is/will be
clearly earmarked, if open storage shall be
considered for the same.
b During the period when the openly stored clinker is
inactive, it should be covered fully by HDPE or tarpaulin
type sheets to prevent wind blowing of fugitive dust.
Cover is/will be provided if clinker would be
stored in open to prevent wind blowing of
fugitive dust.
c Install three sided enclosures, which extend to average
height of the stockpile, where ever feasible.
Wind breaking walls on three sides of open
stock piles is/will be provided
d Flexible type wind breaking enclosure should be provided
covering the clinker retrieval area as wind barrier to
prevent dust carry over by wind.
The enclosure could be of light weight material like
moulded plastic material or similar, which could be
dismantled/assembled and shifted from one place to
other.
Partial enclosure for retrieving area is/will be
provided.
e Travel areas path used by the front end pay loader shall
be paved with concrete. It should be regularly swept by
high efficiency vacuum sweeper to minimize the material
build up.
The travel path of pay loaders is/would be
paved and frequently swept.
f The possibilities especially in new cement plant
may be explored for the following:
An enclosure fitted with bag filter could be located at the
most central place adjacent to the clinker storage area.
The pay loader moves to the fixed loading area from one
end of the enclosure and the truck/trailer enters the
enclosure from other end.
Loading of clinker by pay loaders into trucks/
trailers/ wagon is/will be carried out in an
enclosure fitted with a bag filter.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 209 JM EnviroNet Pvt. Ltd.
6. Storage of Limestone, Gypsum, Fly ash and other additives
S. No. Guidelines Control Measures provided / to be Provided
1. The enclosure walls shall cover minimum two sides up to
roof level.
The storage is/will be done under covered
shed.
2. Fly ash shall be pumped directly from the tankers to silos
pneumatically in closed loop or mechanically such that
fugitive emissions do not occur.
Dry fly ash is/will be transported by closed
tankers and is/will be pumped directly from
the tankers to silos pneumatically in closed
loop.
3. The silo vent will be provided with a bag filter type
system to vent out the air borne fines.
Dry Fly ash is/will be stored in silos only
provided with a bag filter system to the vent
out air borne fines.
4. If possible, the dry fly ash should be sent to closed silos.
Otherwise, fly ash should be transported through closed
belt conveyors to avoid wind carryover of fly ash.
Fly ash is/will be sent to closed silos by
pneumatically enclosed loop.
7. Cement Packing Section
S. No. Guidelines Control Measures provided / to be Provided
1. The packing machines should be equipped with dust
extraction arrangement such that the packing operation is
performed under negative pressure. The dust may be
captured in bag filters.
Dust extraction arrangement for packing
machines is/will be provided.
2. Adequate ventilation for the packing hall should be
provided for venting out suspended particulate thereby
ensuring dust free work environment.
Provide adequate ventilation for the
packing hall.
3. The spilled cement from the packing machine should be
collected properly and sent for recycling.
The spilled cement on the shop floor should be swept by
vacuum sweeping machines periodically.
Proper engineering controls to prevent the fugitive
emissions may include arrangements like providing guiding
plate, scrapper brush for removing adhered dust on cement
bag etc.
Spillage of cement on floor is/will be
minimized and cleared daily to prevent
fugitive emissions.
4. The vibratory screen provided for screening/ recycling
spilled cement should be provided with a dust extraction
arrangement to prevent fugitive emission from that section.
Preventing emissions from the recycling
screen by installing appropriate dust
extraction system.
8. Silo Section
S. No. Guidelines Control Measures provided / to be Provided
1. The bag filter should be operated and maintained
properly, especially the cleaning of bags to avoid
pressurization of silos thereby causing fugitive emissions
from leakages etc.
The silo vent is/will be provided with a bag
filter type system to vent out the air borne
fines.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 210 JM EnviroNet Pvt. Ltd.
9. Roads
S. No. Guidelines Control Measures provided / to be Provided
1.The paved roads should be maintained as paved at alltimes and necessary repairs to be done immediately afterdamages to the road if any.
All roads on which vehicle movement ofraw materials or products take place are/will be paved.
2.Limit the speed of vehicle to 10 Km/h for heavy vehicleswith in the plant premises to prevent the road dustemissions.
Speed of vehicles is/will be limited.
3.Preventive measures include covering of trucks andpaving of access areas to unpaved areas.
Preventive measures are/will be employedto minimize dust build up on roads.
4.Mitigative controls include vacuum sweeping, waterflushing.
To carry out regular sweeping of roads tominimize emissions.
10.3 NOISE MANAGEMENT
Exposure of high noise level to workers for long duration may lead to certain occupational
diseases. To mitigate the high noise level, following measures are/will be adopted.
Walls and ceilings of the concerned buildings are being / will be lined with sound absorbing
materials
Properly insulated enclosures are being /will be provided to equipment making excessive
noise
Improved silencers are being /will be provided in the equipment generating high noise
Isolating continuous vibrating structures/ machines by proper and secured mountings
Proper maintenance, oiling and greasing of machines at regular intervals is being/will be
done to reduce generation of noise
Personal Protective Equipment like earplugs and earmuffs are being/will be provided to the
workers exposed to high noise level
Greenbelt of appropriate width at the plant boundary is being developed
Regular monitoring of noise level is being/will be carried out and corrective measures in
concerned machinery is being /will be adopted accordingly to the possible extent.
10.4 WATER MANAGEMENT
10.4.1 Water Requirement
The water requirement for existing Integrated Cement Plant is 2750 KLD. Additional 750 KLD will
be required for the proposed expansion project; hence, the total water requirement after the
proposed expansion project will be 3500 KLD; which will be sourced from Ground water.
Status of Approval: Permission for withdrawal of ground water for 4000 KLD has already been
obtained from CGWA vide letter no. 21-4(12)/ WR/ CGWA/ 2005-616 dated 23rd May, 2011, 21-4(12)/
WR/ CGWA/ 2005-1220 dated 12th July, 2013 and 21-4(12-B)/ WR/ CGWA/ 2005-255 dated 11th
February, 2014.
Details of Water Requirement and Water Balance Diagram is given Chapter - II, Section 2.4.3 of this
EIA / EMP Report.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 211 JM EnviroNet Pvt. Ltd.
10.4.2 Waste Water Management
No waste water is being / will be generated from the Cement manufacturing process.
Domestic wastewater generated from plant and colony is being / will be treated in STP and
treated water is being / will be utilized for greenbelt development / plantation.
RO reject water is being / will be used in Synthetic Gypsum manufacturing process, ash
quenching and dust suppression.
No waste water is being / will be discharged outside the plant premises and the same has
been shown in water balance diagram.
10.4.2.1 Sewage Treatment Plant
The domestic effluent generated is being treated in Sewage Treatment Plant of capacity 200 KLD
installed in plant and domestic waste water of colony will be treated in proposed STP of capacity
275 KLD (200 +75).
Process description of the existing STP
Bar screen chamber followed by collection cum equalization tank followed by Fluidized Aerobic
Bed Reactors (2 Nos.) will be provided with coarse air bubble diffusion system followed by Tube
Settler Tank in the STP. The clear supernatant after disinfecting by chlorination will be passed
through dual filter and activated Carbon filter and collected in the treated water tank. The sludge
generated from the FAB will be passed through sludge digester and dried and the filtrate will be
collected and sent back to the equalization tank and the dried cakes will be used as manure. The
treated water will be used for plantation activities.
The schematic diagram for sewage treatment plant has been shown in Figure - 10.3and
photographs showing existing STP is given in Figure - 10.4.
Figure 10.3: Schematic Diagram for Sewage Treatment Plant
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 211 JM EnviroNet Pvt. Ltd.
10.4.2 Waste Water Management
No waste water is being / will be generated from the Cement manufacturing process.
Domestic wastewater generated from plant and colony is being / will be treated in STP and
treated water is being / will be utilized for greenbelt development / plantation.
RO reject water is being / will be used in Synthetic Gypsum manufacturing process, ash
quenching and dust suppression.
No waste water is being / will be discharged outside the plant premises and the same has
been shown in water balance diagram.
10.4.2.1 Sewage Treatment Plant
The domestic effluent generated is being treated in Sewage Treatment Plant of capacity 200 KLD
installed in plant and domestic waste water of colony will be treated in proposed STP of capacity
275 KLD (200 +75).
Process description of the existing STP
Bar screen chamber followed by collection cum equalization tank followed by Fluidized Aerobic
Bed Reactors (2 Nos.) will be provided with coarse air bubble diffusion system followed by Tube
Settler Tank in the STP. The clear supernatant after disinfecting by chlorination will be passed
through dual filter and activated Carbon filter and collected in the treated water tank. The sludge
generated from the FAB will be passed through sludge digester and dried and the filtrate will be
collected and sent back to the equalization tank and the dried cakes will be used as manure. The
treated water will be used for plantation activities.
The schematic diagram for sewage treatment plant has been shown in Figure - 10.3and
photographs showing existing STP is given in Figure - 10.4.
Figure 10.3: Schematic Diagram for Sewage Treatment Plant
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 211 JM EnviroNet Pvt. Ltd.
10.4.2 Waste Water Management
No waste water is being / will be generated from the Cement manufacturing process.
Domestic wastewater generated from plant and colony is being / will be treated in STP and
treated water is being / will be utilized for greenbelt development / plantation.
RO reject water is being / will be used in Synthetic Gypsum manufacturing process, ash
quenching and dust suppression.
No waste water is being / will be discharged outside the plant premises and the same has
been shown in water balance diagram.
10.4.2.1 Sewage Treatment Plant
The domestic effluent generated is being treated in Sewage Treatment Plant of capacity 200 KLD
installed in plant and domestic waste water of colony will be treated in proposed STP of capacity
275 KLD (200 +75).
Process description of the existing STP
Bar screen chamber followed by collection cum equalization tank followed by Fluidized Aerobic
Bed Reactors (2 Nos.) will be provided with coarse air bubble diffusion system followed by Tube
Settler Tank in the STP. The clear supernatant after disinfecting by chlorination will be passed
through dual filter and activated Carbon filter and collected in the treated water tank. The sludge
generated from the FAB will be passed through sludge digester and dried and the filtrate will be
collected and sent back to the equalization tank and the dried cakes will be used as manure. The
treated water will be used for plantation activities.
The schematic diagram for sewage treatment plant has been shown in Figure - 10.3and
photographs showing existing STP is given in Figure - 10.4.
Figure 10.3: Schematic Diagram for Sewage Treatment Plant
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 212 JM EnviroNet Pvt. Ltd.
Figure 10.4: Photographs of Existing STP
10.4.3 Water Conservation
The following measures will be adopted to minimize use of ground water-
Reuse of domestic wastewater after treatment
Reuse of RO reject water in manufacturing of synthetic gypsum and for dust suppression /
ash quenching
Periodic preventive maintenance of water distribution systems
Rain water harvesting at plant site
Training and awareness on water conservation measures
10.4.3.1 Rain Water Harvesting at Plant and Colony
The demand of water for industrial purposes, agricultural purposes, domestic purposes and other
miscellaneous purposes is increasing considerably around Shree Cement Ltd. There are surface
water sources in the area but as stated above, in the deficiency of that surface water sources, it is
equally important and urgent to ensure the full proof supply of required quantity of water
throughout the year without any disturbance to industrial activity as well as without causing any
negative water scarcity impact on the neighboring villages. To achieve this target maximum
quantity of Rain Water has to be harvested and reserved (charged) in the available sub-surface
cavities or collected and infiltration must be facilitated through the management practice.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 213 JM EnviroNet Pvt. Ltd.
Earthern Pit near Dispensary Mine Pit no.1 - Nimbeti Limestone Mine
Mine Pit No.2 near butiwasEarthern Pit in Bagatpura colony
Open Well no.5 (Behind labor Canteen) Open Well no.4 (Near Kheda Gate)
Figure - 10.5: Photographs showing Rain Water Harvesting
Table - 10.4
Proposed Rainwater harvesting in Plant and Colony area
S. No. Method applied for Rain Water HarvestingQuantity of rain water to be
harvested Cum/ Annum
Plant Premises
1. Rooftop Rainwater Harvesting 12539
2. Blacked Topped roads and cemented area 301174
3. Open land 180087
4. Green belt 2889
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 214 JM EnviroNet Pvt. Ltd.
Colony
5. Roof top rainwater Runoff 19291
6. Blacked Topped roads and cemented area 62300
7. Open land 13261
8. Nala Originating from Eastern side of Industrial Unit 453974
9. Nala Originating from Eastern and South-Eastern Side of Colony area 523320
Total Rainwater Recharge Potential in the Plant Premises 1568835
10.5 WASTE MANAGEMENT
10.5.1 Solid Waste Management
No solid waste is / will be generated in cement manufacturing process. Solid waste generation
from the project and their end use is given in table below:
Table - 10.5 (a)
Solid Waste Generation and their End Use
S. No. Type of Waste End Use / Disposal
1. Dust collected from air pollution control equipment Totally recycled in process
2. Sludge from Sewage Treatment Plant Manure for greenbelt development
3. Fly ash from CPP Utilization in manufacturing of PPC grade cement
Details of fly ash generation is given in table below:
Table - 10.5 (b)
Quantity of Fly Ash Generation
Description Unit Quantity (CFBC / AFBC)
ASH HANDLING SYSTEM Pneumatic system will be used for the handling of fly ash
Fly ash quantity Kg/hr 87450
Bed ash quantity Kg/hr 101310
Total ash quantity Kg/hr 188760
10.5.2 Hazardous Waste Managements
No hazardous waste is being / will be generated except the used oil which is being / will be
collected in drums, temporarily stored at earmarked place stored as per Hazardous and Other
Waste (Management & Trans-boundary Movement) Rules, 2016 and is being / will be sold to the
authorized CPCB recyclers. Details are given in table below:
Table - 10.6
Hazardous Waste Generation
S. No. Type of WasteWaste
Category
MT per YearTreatment/Disposal
Existing Additional Total
1. Used Oil 5.1 300 25 325Sold to CPCB
authorized recycler
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 215 JM EnviroNet Pvt. Ltd.
Use of High Calorific Hazardous Waste in Cement Plant
The co-processing of waste in cement industry is much beneficial option, whereby wastes are not
only incinerated at a higher temperature of around 1400°C and longer residence time but its
inorganic content gets fixed within the clinker apart from using the energy content of the wastes.
Apart from this, no residues are left, which in case of incineration still requires being land filled as
incinerator ash. Further the acidic gases, if any generated during co-processing gets neutralized,
since the raw material is alkaline in nature. Such phenomenon also reduces resource requirement
such as coal and limestone.
Taking the cognizance of above advantages of co-processing the waste, Shree Cement Ltd. have
explored few hazardous waste in the area generated by other units and is utilizing them as AFR.
Details of the Hazardous waste used in the Plant is given in Table 10.7:
Table - 10.7
Hazardous Waste Utilization
S.No. Name of Hazardous Waste Source
1. Paint Sludge
Honda Motorcycle and Scooter India Pvt. Ltd.; Maruti Suzuki, Gurgaon;
India Yamaha Motor Pvt. Ltd. Noida; CETP Pali (Raj.); Honda Cars India
Ltd. SPL1; Tapukara Industrial Area, Alwar, Raj.; New Hollande Fiat India
Pvt., Udyog Kendra Greater Noida; Sunbeam Auto Pvt. Ltd. SP1-D,
Industrial Area, Tapukara (Bhiwadi), Alwar.
2. Phosphate Sludge Honda Motorcycle and Scooter Ind. Pvt. Ltd.
3. ETP Sludge
Maruti Suzuki, Gurgaon; Palijal Pradusan Niantran, Parisodhan &
Anusandhan Foundation, New Hollande Fiat India Pvt. Ltd., Udyog
Kendra, Greater Noida
4. Oil Soaked Cotton Maruti Suzuki, Gurgaon
Permission for the same has been taken vide letter no. F(HSW)/Pali(Jaitaran)/1(1)/2008-2009/913-
915 dated 24th June, 2015 for paint sludge and phosphate sludge, letter no.
F(HSW)/Pali(Jaitaran)/5(1)/2013-2014/3622-3624 dated 31st July, 2013 for ETP Sludge and letter no.
F(HSW)/Pali(Jaitaran)/13(1)/2015-2016/1738-1740 dated 11th Aug., 2015 for Oil Soaked Cotton. Copy
of the same has been enclosed as Annexure - 13 along with this EIA / EMP Report.
Quantity wise use of Hazardous waste in kiln for the Financial year 2015-16 is given in Table 10.8.
Table - 10.8
Hazardous Waste Utilization in 2015 - 16
Month Paint Sludge (MT) Phosphate Sludge (MT) ETP Sludge (MT) Oil Soaked Cotton (MT)
April, 2015 31 17.19 602.31 -
May, 2015 55.08 - 602.68 -
June, 2015 74.85 - 543.235 -
July, 2015 95.45 - 281.07 -
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 216 JM EnviroNet Pvt. Ltd.
Month Paint Sludge (MT) Phosphate Sludge (MT) ETP Sludge (MT) Oil Soaked Cotton (MT)
August, 2015 33.19 - - -
September, 2015 116.195 - 464.1 -
October, 2015 114.805 - 992.71 -
November, 2015 91.41 - 463.68 -
December, 2015 119.14 - 273.8 21.1
January, 2016 182.775 - 955.905 50.025
February, 2016 79.03 - 586.545 20.35
March, 2016 64.6 6.36 803.285 10.34
10.6 CONCEPT OF WASTE MINIMIZATION, 3R S (REUSE, RECYCLE & RECOVER TECHNIQUES), ENERGY
AND NATURAL RESOURCE CONSERVATION MEASURES
10.6.1 Waste Minimization - 3R S
10.6.1.1 Reuse
Waste generated from construction activity will be utilized in leveling of land
Fly Ash generated from CPP is being / will be totally reused as raw material in cement
manufacturing process
10.6.1.2 Recycle
Treated water from STP is being / will be reused in greenbelt development / plantation
RO reject water is being / will be used in Synthetic Gypsum manufacturing process, ash
quenching and dust suppression
The dust collected from pollution control equipment will be recycled in the process
Ro and softener reject water will be used for Ash quenching and dust suppression
10.6.1.3 Recovery
The sludge generated from the STP will be used as manure for greenbelt development /
plantation.
10.6.2 Energy Conservation
Cement manufacturing is an energy-intensive process.
The following measures have been proposed by Shree Cement Ltd. for further reduction in
specific energy consumption:
Installation of energy efficient lightings (like LED). Use of energy saving light fittings
Installing low watt tube lights
Raw mix optimization
Procurement of energy efficient machineries
Minimizing idle running of vehicle, machines and electrical appliances
Optimizing loads and periodic preventive maintenance and lubrication
Prevention of leakages of compressed air
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 217 JM EnviroNet Pvt. Ltd.
Periodic energy audits
Training, awareness and motivational programmes
Maximum utilization of renewable energy resources
Company is Expanding the capacity of Waste heat recovery Power Plant from 68 MW to 90
MW for energy conservation.
10.6.3 Natural Resource Conservation
Efficient use of energy by installing multistage Pre-heater/ Pre-calcinator kilns will significantly
reduce the fuel (i.e. coal / alternate fuel) requirements.
Use of potential waste material for energy recovery/raw material as alternative fuel and raw
material (AFR) as per availability and subject to permission from the competently authority
Waste Heat Recovery System for generation of electricity, reduction of CO2 emission and
conservation of fossil fuel
Optimum use of ground water
Recycle and reuse of domestic wastewater to conserve the fresh water
Zero effluent discharge from industrial and domestic activities
Rain water harvesting system has been/ will be installed to conserve water and to replenish
ground water resources of the area for long term sustenance of the industry. Rain Water
Harvesting has been/ will carried out by the following methods:
o Roof top rainwater harvesting
o Surface rainwater runoff available from paved area, green area and open land has been/
will used for recharging through injection wells
o Natural rainfall recharge to open land
10.7 GREENBELT DEVELOPMENT AND PLANTATION PROGRAMME
Shree Cement Ltd. has already developed greenbelt / plantation in an area of 63.8 ha; additional
14.5 ha will be further developed for this expansion project. Besides this, 33% (i.e. 24 ha) of the
area available outside the plant boundary (72.7 ha) will also be developed under greenbelt /
plantation, whenever used in future.
Area of the township near village Bagatpura is 40 ha, out of which 14.5 ha (i.e. 36%) is developed
under greenbelt / plantation area.
The company has social obligation to recreate the environmental status by providing thick canopy
cover to suppress fugitive emission and provide aesthetic beauty. Trees form important part of
the biosphere in the Eco-system. The ecological belt maintains the natural balance of the area.
A green belt of tree plantation around the plant site will help to arrest the particulate matter in
the area and hence attenuate the pollution to a great extent.
The following characteristics have been taken into consideration while selecting plant species for
green belt development and tree plantation.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 218 JM EnviroNet Pvt. Ltd.
I. They should be fast growing and tall trees
II. They should be perennial and evergreen
III. They should have thick canopy cover
IV. The planting should be in appropriate alternate rows around the site to prevent lateral
pollution dispersion
V. The trees should maintain regional ecological balance and conform to soil and hydrological
conditions. Indigenous species should be preferred.
10.7.1 Greenbelt Plantation at Plant Site
Due care is/will be taken to ensure that a green belt is developed around the plant area. Areas
having low density vegetation are/will be systematically and scientifically afforested. The
plantation scheme broadly covers the following areas:
Green belt formation around the plant site
Afforestation of barren and non-industrial areas
Apart from the green belt and aesthetic plantations for fugitive emissions and noise control, all
other massive plantation efforts are/will be executed with the assistance and co-operation of the
local community. The plantations of any of the above or their combinations is/will be decided in
consultation with the local community and District Forest Department.
10.7.2 Objective
Greenbelt is a set of rows of trees planted such a way that they form an effective barrier
between the plant and the surroundings. The main purpose of green belt development is to
contribute to the following factors:
To attenuate noise levels generated from the plant;
To improve the aesthetics of the plant area;
To trap the vehicular emissions and fugitive dust emissions;
To maintain ecological homeostasis;
To prevent soil erosion and to protect the natural vegetation; and
To utilize the treated effluents.
Provision of wide green belt around the plant and colony has been foreseen to reduce any
adverse impacts on the surrounding population due to emissions from the proposed activity.
Plantation of grass, flowers, bushes and trees is/will be taken-up to reduce generation of dust
from bare earth and to enhance the aesthetic/scenic value.
10.7.3 Plantation Programme
The Company has raised greenbelt/ plantation in an area of 63.8 ha.
Following native plant species have been/will be planted by SCL in consultation with local
horticulturist:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 219 JM EnviroNet Pvt. Ltd.
Trees Shurbs
Azadirachta indica (Neem)
Delonix regia (Gulmohar)
Peltophorum ferrugineum (Yellow Gulmohar)
Dalbergia sisso (Seasam)
Pongamia pinnata (Karanja)
Kigelia pinnata (Balamkheera)
Lagerstroemia indica (Largestomia)
Erythrina indica (Indian coral trees)
Albizia Julibrissin (Siris)
Thespesia populnea (Paras Pipal)
Cassia siama (kasood)
Jacaranda mimosisolia (Nili Gulmohar)
Bauhinia Blakeana (Kachnar)
Mimusops Elengi (Molshree tree)
Alianthus Exelsa (Ardoo)
Alostonia scholaris (Saptparni)
Cassia fistula (Amaltas)
Ficus religiosa (Pipal)
Callistemon lanceolatus (Bottle brush)
Pterospermum acerifolium (Kanak Champa)
Ashoka pendula (Ashok)
Terminalia cattapa (Desi Badam)
Parkinsonia aculeata (Parkinsonia)
Acacia auriculiformis (Australian Babool)
Tecoma Stans (Yellow bells)
Thevetia peruviana (Pilli Kaner)
Calliandra brevipes (Forest ghost flower)
Bougainvellia glabra (Bougainvellia)
Ficus Panda (Ficus Panda)
Cassia Biflora (Cassia Biflora)
Jatrophacurcas (Ratanjyot)
Ficus starlight (Ficus Starlight)
Nerium oleander (Red Kaner)
Caesalpinia pulcherrima (Krishanchura)
bahunia tomentosa (Kachanar)
Pithecellobium dulce (Jungle Jalebi)
Hibiscus - rosa chinesis (Gudhal)
Nyctanthes arbor- tristis (Harsingar)
Tabernaemontana divaricate (Chandani)
Year-wise greenbelt / plantation done at Shree Cement Ltd. is given in Table - 10.9
Table - 10.9
Existing Plantation Details
Year Number of species planted Area (ha)
2004 - 2005 6000 9
2005 - 2006 15000 12.5
2006 - 2007 22950 5.31
2007 - 2008 19632 11.36
2008 -2009 24418 25.64
2009 - 2010 6869 -
2010 - 2011 23336 -
2011 -2012 18552 -
2012 - 2013 15648 -
2013 - 2014 12335 -
2014 - 2015 232 -
2015 -2016 339 -
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 220 JM EnviroNet Pvt. Ltd.
Total 165311 63.81
10.7.4 Photographs showing Existing Green Belt Development
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 221 JM EnviroNet Pvt. Ltd.
Proposed Action Plan for Greenbelt Development / Plantation at SCL is given in Table- 10.10.
Table - 10.10
Action Plan for Greenbelt development / Plantation
S. No. Year Area (Ha) No. of Plants per ha Total Nos. of Plant
1. 2014- 2015 2 1200 2400
2. 2015- 2016 3 1200 3600
3. 2016- 2017 3 1200 3600
4. 2017- 2018 3 1200 3600
5. 2018- 2019 3.5 1200 4200
Total 14.5 6000 17400
10.7.5 Guidelines for Green Belt Development
Following guidelines will be followed for the Green Belt Development Plan in the plant and
colony area.
1) All the barren areas should be vegetated. Areas other than this are having good natural
vegetation. Soil and other environment are very encouraging and the expected growth rate
should be more than 90%
2) Trees growing to a height of 5m or more should be planted
3) Plantation of trees should be undertaken in around the area in alternating rows to prevent
horizontal pollution dispersion
4) Trees should be planted along road sides, to arrest auto-exhaust and noise pollution, and in
such a way that there is no direct line of sight to the installation when viewed from a point
outside the foliage perimeter
5) Since tree trunks are normally devoid of foliage (upto 3 m), it should be appropriated to
have shrubbery in form of such trees to give coverage to this portion
6) Fast growing trees with thick perennial foliage should be grown, as it will take many years
for trees to grow to their full height
In order to facilitate proper growth of the vegetation, a limited measures involving preparation
of seed bed with suitable amount of fertilizers and treatment with mulches is/will be taken. The
topsoil should be used for green belt development.
Vegetation covers in and around the plant workings generally helps in:
Stabilizing erodible slopes to minimize pollution
Control of dust
Enhancement of aesthetic value
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 222 JM EnviroNet Pvt. Ltd.
Maximizing evapo -transpiration, which helps minimizing run off
Reducing noise
10.8 OCCUPATIONAL HEALTH AND SAFETY MEASURES
To control and minimize the risks at workplace, Shree Cement Ltd. has implemented Health,
Safety and Environment Policy with the following objectives:
To prevent hazards
To provide safe and healthy environment to all the employees.
The company, therefore, has adopted the policy set below for the purpose of creating and
maintaining safe and healthy environment.
10.8.1 Health and Safety Policy
Health, Safety and Environmental Protection (HSE) is a part of Shree Cement Ltd.
commitment to conduct the activities in harmony with society and nature. The company
expects all its employees to implement the HSE Policy.
Integration process of H&S must start at the inception of a project since H&S consideration
must be addressed at the design stage, which also helps in optimizing the support process.
SCL will have integrated Health, Safety and Environment Protection into the business
strategies to add value to the enterprise, to manage risk and to enhance the reputation.
The health and safety of the employees, neighbors, customers and consumers, and the
protection of the environment will be company s priorities consistently pursued throughout.
Each employee will be made to comply with the HSE guidelines and the laws applicable to her
or his area of operational responsibility.
10.8.2 Occupational Health and Safety Hazards
Following Occupational Health and safety Hazards will be there in the proposed expansion in
Cement Plant:
Dust
Noise
Heat stress
Electrical Hazards
Fire and Explosion
Other Hazards
(1) Dust
A) Risks involved
Following risks are involved:
Presence of crystalline silica may cause silicosis and lung cancer
Cement and other dust may cause lung disease
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 223 JM EnviroNet Pvt. Ltd.
B) Management Measures
Implementation of adequate dust control systems and good housekeeping will be done.
C) Exposure Levels
DescriptionPersonal Exposure, time weighted average 8 hr. RSPM in µg/m3
Norms Exposure Level
Coal and Pet coke dust 2000 1552
Limestone dust 10000 4362
Cement Dust 10000 4299
Crystalline Silica ND
(2) Noise
A) Risks involved
Following risks are involved:
Hearing Impairment, Hypertension, Increase Pulse rate
Annoyance, Tinnitus, Sleep Disturbances
B) Management Measures
Proper maintenance of machineries
Installation of compressors and turbine in closed buildings
Regular monitoring of noise level
Display of noise level with permission level
Display instruction to use of PPEs at high noise level area
Periodic health checkup for audiometry for the person working in high noise area
C) Exposure Levels
S. No. Area CPCB Norms, dB(A) Exposure Level, dB(A)
1. Compressor House
90 dB(A) as per Factory
Act 1978
81
2. Turbine Area 80
3. Near Crusher 68
4. Raw Mill 80
5. Coal Mill 78
6. Cement Mill 79
7. Packing Area 76
(3) Heat stress
A) Risks involved
Following risks are involved:
Cement plants operate at high temperatures up to 1500 degrees C with high loads of raw
material
B) Management Measures
Schedule hot jobs for the cooler part of the day
Monitor workers who are at risk of heat stress
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 224 JM EnviroNet Pvt. Ltd.
Provide rest periods with water breaks
Use of personal protective equipment
(4) Electrical Hazards
A) Risks involved
Following risks are involved:
Electric Shock, Electric Burns, Fires and Explosions
Persons Falling from Height, Dropping of Tools and Object
B) Causes of Hazards
Insulation Failure, Equipment Failure, Poor Maintenance.
Wrong Work Methods, Substandard Material and workmanship
Unauthorized personal & Lack of Training and Knowledge, etc.
C) Management Measures
Following protection measures will be taken:
Proper Earthing will be done as per IS 3043
Low Voltage Supply will be ensured
Isolating Transformers
Double Insulated Tools
Over Load Protection
Protection Against Leakages (G.F.C.I.)
Flame- Proof Equipment
Lightning Protection
Protection against Static Electricity and safe use of ladders and scaffolds
(5) Fire and Explosion
A) Risks involved
Following risks are involved:
Fire catching in store, bag godown, conveyors, cable tunnel, oil storage area and coal
storage, transformers and HT/LT substation etc.
B) Management Measures
Suitable fire extinguisher, fire hydrant system and fire buckets. Dry power type in oil
and fire buckets are kept near transformer, cable, general store and office area.
Hydrant line in coal, clinker storage area and at all location in plant area. Fire tender is
kept ready at plant main gate
Oil and Flammable Gases storage area fenced and declared as Fire Hazardous Area-No
Smoking Area
Permit and safety instruction to use welding / gas cutting in the area of oil, gas, coal and
bag godown
Predictive interlock in transformers to give alarm and trip the system
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 225 JM EnviroNet Pvt. Ltd.
Adequate height of brick walls for separation of all transformers, soak pits for storage
of oil leakages from transformers
(6) Other Hazards
A) Risks involved
Following risks are involved:
Silo and Buildings Collapse
Slipped and Fall from working at height
Failure of lifting tools, tackles and pressure vessel,
Occupational injuries
Hit by moving, flying or falling object
B) Management Measures
Following protection measures will be taken:
Structural soundness of silos and buildings
Installation of light arrestors at all tall buildings
Permit to work at height with work instruction to use safety belts etc
Testing of all lifting tools, tackles and pressure vessel
Safe working pressure is maintained in air receiver
Safe working load for cranes and ropes etc
Good housekeeping& Speed limit of 20km/hr in plant area
Display of emergency number at all suitable location
Fire tender, ambulance and emergency staff ready at the plant main gate at all the time
First aid kits are kept at the sites and training provided
Use of mobile while driving, alcohol, smoking etc are bane in plant area
Proper illumination in office (250 to 300 LUX), plant area (100 to 150 LUX and road area
(20 to 30 LUX)
10.8.3 Occupational Health Surveillance
In cement plant, the occupational health surveillance of the employee is/will be done on a regular
basis and records of the same are/will be maintained as per the Factories Act. The occupational
health surveillance programme include lung function; sputum analysis and audiometric analysis on
regular basis to observe any contraction due to exposure to dust and noise and corrective
measures are/will be taken accordingly.
Vocational training programmes are/will also be conducted. Under vocational training the workers
are/will be given training related to all safety and health aspects pertaining to their vocation and
thereafter every quarter special training courses/ Awareness programme for Malaria eradication,
HIV and health effects on exposure to dust, heat, noise, chemicals are/will be organized for
employed person.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 226 JM EnviroNet Pvt. Ltd.
Periodical medical camps with specialized doctors of various disciplines also provide the
specialized medical assistance to employees as well as neighboring communities.
A. List of Equipment for Occupational Health Monitoring (Existing)
ECG
Glucometer
Laryngoscope
Suction Machine
Autoclave
Sterilizer
Spirometer
TMT
Audiometric device
Chest X Ray
Complete Medical Laboratory Set up
D.C. Shock and Cardiac Monitor
Endoscopic Ear & Throat
Urine Analyzer
B. List of Equipment for Occupational Health Monitoring (Proposed)
Dental Chair
HbSAg Meter
USG
Digital X-Ray
C. Pre Placement and Periodical Health Status
Pre /post-employment checkup will be carried out and following tests will be conducted:
Chest x rays
Vision testing (Far and Near vision, color vision and any other ocular defect)
ECG
Haemogram (examination of the blood)
Blood Sugar Fasting
Serum Cholesterol
Serum Creatinine
SGOT and SGPT
Urine (Routine and Microscopic)
Complete physical examination
Post employment occupational health check up such as lung function, audiometry, CBC,
Blood Sugar, Lipid Profile etc.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 227 JM EnviroNet Pvt. Ltd.
Medical records of each employee will be maintained separately and will be updated as
per finding during monitoring
Medical records of the employee at the end of his / her term will be updated
D. Frequency of Medical Examination
Yearly
E. Personal Protective Devices and Measures
Industrial Safety helmets
Crash helmets
Face shield with replacement acrylic vision
Zero power goggles with cut type filters on both sides and blue color glasses
Welders equipment for eye and face protection
Ear plug and Ear muffs
Canister gas masks
Self contained breathing apparatus
Leather apron
Safety belt / line man's safety belt
Rope grab fall arrestor
Leather hand gloves
Canvas cum leather hand gloves with leather palm
Industrial safety shoes with steel toe
Electrical safety shoes without steel toe and gum boots
Protective clothing etc.
F. Anticipated Occupational and Safety Hazardous
Heat Stress and Stroke
Physical activity
Dehydration
Cardiovascular disease
Skin disorders
Dust Exposure
Metallic dust exposure
Noise
Burns and shocks due to electricity
G. Details of Test conducted
Details of various test conducted is given below:
Spirometry
Name of Dept. Total Employees FVC (litres) FEV 1 FEV 1/ FVC %PEFR
MVV (litres/min) Conclusion(litres/sec)
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 228 JM EnviroNet Pvt. Ltd.
Plant 120 WNL WNL WNL WNL WNL WNL
Total No. of
employees120 Normal Normal Normal Normal Normal 100 % Normal
Biochemical Parameter (Urine)
Name of Dept. Total Employees Sp. gravity pH RBC Protein Sugar
Civil 40 WNL WNL Nil Nil Nil
Commercial 158 WNL WNL Nil Nil Nil
Process 169 WNL WNL Nil Nil Nil
Drawing & Design 15 WNL WNL Nil Nil Nil
Electrical 96 WNL WNL Nil Nil Nil
SPP 347 WNL WNL Nil Nil Nil
Lab and QC 76 WNL WNL Nil Nil Nil
Medical 10 WNL WNL Nil Nil Nil
Instrumentation 96 WNL WNL Nil Nil Nil
Mechanical 238 WNL WNL Nil Nil Nil
P & A 115 WNL WNL Nil Nil Nil
Total No. of employees 1360 Normal Normal Normal Normal Normal
Biochemical Parameter (Blood)
Name of Dept.Total
EmployeesCBC
Lipid
ProfileRenal Profile
Liver Function
TestBlood Sugar
Civil 40 WNL WNL WNL WNL WNL
Commercial 158 WNL WNL WNL WNL WNL
Process 169 WNL WNL WNL WNL WNL
Drawing & Design 15 WNL WNL WNL WNL WNL
Electrical 96 WNL WNL WNL WNL WNL
SPP 347 WNL WNL WNL WNL WNL
Lab and QC 76 WNL WNL WNL WNL WNL
Medical 10 WNL WNL WNL WNL WNL
Instrumentation 96 WNL WNL WNL WNL WNL
Mechanical 238 WNL WNL WNL WNL WNL
P & A 115 WNL WNL WNL WNL WNL
Total No. of employees 1360 Normal Normal Normal Normal Normal
Circulatory System Vision
Name of Dept. Total Employees Pulse ECG BP Right Eye Left Eye Color Blindness Squint
Civil 40 Normal WNL Normal Normal Normal Nil Normal
Commercial 158 Normal WNL Normal Normal Normal Nil Normal
Process 169 Normal WNL Normal Normal Normal Nil Normal
Drawing & Design 15 Normal WNL Normal Normal Normal Nil Normal
Electrical 96 Normal WNL Normal Normal Normal Nil Normal
SPP 347 Normal WNL Normal Normal Normal Nil Normal
Lab and QC 76 Normal WNL Normal Normal Normal Nil Normal
Medical 10 Normal WNL Normal Normal Normal Nil Normal
Instrumentation 96 Normal WNL Normal Normal Normal Nil Normal
Mechanical 238 Normal WNL Normal Normal Normal Nil Normal
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 229 JM EnviroNet Pvt. Ltd.
P & A 115 Normal WNL Normal Normal Normal Nil Normal
Total No. of
employees1360 Normal WNL Normal Normal Normal Nil Normal
10.8.4 Implementation of OHS standards as per OSHAS/USEPA
The overall objective of the company is to provide a system that is capable of delivering healthy
and safe workplace. Following measures have been adopted for implementation of OHS
standards.
Well-equipped Occupational Health Centre with adequate paramedical staff
Routine and special investigation related to occupational health
Health surveillance & maintenance of health record
Rules and procedure for effective implementation of Safety, Health and Environment policy
and made to know all employees
Round the clock Ambulance facility
Sufficient number of First aid boxes
Implementation of OHSAS 18001 for Occupational, Health and Safety Management System
Implementation of ISO 14001 for Environment Management System
Formulation of OHS implementation team/ cell
Risk assessment of each and every activity
Implementation of OHS management program
Displaying the safety and health policy and instructions at various locations
Display of safe operating procedure (SOP) at various locations
Job safety analysis
Carry out daily plant safety inspection by internal safety department
Investigation of fatal, serious accidents and near miss accident
Investigation of reports of occupational diseases
Monthly safety meeting of all employees and workers to discuss last month accident if any,
reason and corrective measures taken.
Organize campaigns, competitions, contests etc. to promote safety
Organize safety training, seminars for safe working and safe vehicle and traffic movement
within the plant premises and regular training for safe driving outside the plant premises
Prepare annual reports of accidents and occupational diseases. Preparation and updating of
Onsite Emergency Plan and Liaison with external agencies and authorities
Ensure use of PPEs according to the job like helmet, safety shoes, goggle, dust mask, ear
plug and hand gloves etc.
Establishment of Occupational Health Centre for pre and periodic medical examination of
workers and staff to detect any onset of occupational disease and corrective manures
Display Material Safety Data Sheets (MSDS) for use of every hazardous substance
Implement the recommendations of HAZOP (A hazard and operability study) for
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 230 JM EnviroNet Pvt. Ltd.
examination of problems in existing process / operation that may represent risks to
personnel or equipment
Periodic Safety Audits both internal and external, review and implementation of
recommendations
10.8.5 Safety Committee
A safety committee is / will be formed and manned by equal participation from management and
workers with the following functions:
a) Accident prevention and control including ensuring the use of safety appliances
b) Publicity, propaganda, education and training
c) Assisting and cooperating with the management in achieving the aims and objectives
outlined in the Health and Safety Policy of the occupier
d) Carrying out health and safety surveys for identifying unsafe working condition/practices,
which causes accident
10.8.6 Medical Facilities
SCL is/will be provided with occupational health centre functioning round the clock. Qualified
doctor and 24 Hrs. availability of pharmacist and ambulance is/will be there at site to render the
medical assistance. Tie up arrangements are/will be there with nearest hospital and nursing home
for the plant. First aid boxes are/will be kept in 15 identified locations for emergency.
Apart from these, specialists will visit SCL Plant to render consultation. Camps for immunization,
family planning, blood donation and free medical checkup programs are/will be organized on
regular basis for employees as well as neighboring communities.
10.8.7 Investigation Facility
Full-fledged pathological laboratory, X-ray machine with routine and specialized investigation
facilities are/will be made available at the plant.
10.8.8 Facility for Minor Surgical Operation
The hospitals are/will be having all the infrastructure facilities to perform minor surgical
procedures like fracture, stitches and foreign body removal from eye, nose, ear, burns and
electrical injury.
10.8.9 Ambulance Services
The hospitals are/will be provided with an ambulance to bring the patients to hospital in case of
emergency.
10.8.10 First Aid Boxes
First aid boxes are/will be provided at prominent places with following items:
Small size sterilized dressing
Medium size sterilized dressing
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 231 JM EnviroNet Pvt. Ltd.
Large size sterilized dressing
Burnol Ointment
Packets of sterilized cotton wool
Bottle (120 ml) of cetramide solution (1%) of suitable antiseptic solution
Mercurochrome solution (in 2% water)
Scissors
Adhesive plaster (2 cm x 1 m)
Sterilized eye pads in separate sealed packets
Aspirin tablets
Potassium Permanganate crystals
First aid boxes are/will be kept in every department for emergency. First aid training are/will be
organized for the employees.
10.8.11 Plan and Fund allocation for Occupational and Safety Hazards
Plan and fund allocation to ensure the occupational health and safety of all contracts and sub-
contract workers is given in Table - 10.11.
Table - 10.11
Fund allocation for Occupational and Safety Hazards
Safety Expenses (Rs. In Lacs) Health Expenses
Year Capex Revenue Grand Total This includes cost of Medicines, first aid
Material, repair of equipment, Visiting
Specialist Fees, running and maintenance
expenses of Medical Centre and Periodical
medical examination expenses.
1st Year 50 15 65
2nd Year 25 15 40
3rd Year 25 10 35
10.9 CORPORATE ENVIRONMENT POLICY
Corporate Environment Policy of SCL has been enclosed as Annexure - 8 along with this EIA/EMP
Report.
10.10 VEHICULAR POLLUTION CONTROL AND ITS MANAGEMENT
Vehicle emissions are responsible for 70% of the country s air pollution. Various laws in this regard
have been laid out by the government. Air pollution from vehicle exhaust and industry is a
worsening problem for India. Exhaust from vehicles has increased eight-fold over levels of twenty
years ago; industrial pollution has risen four times over the same period. The economy has grown
two and a half times over the past two decades.
SCL take care of all the measures to take up the vehicular pollution control in addition to the
pollution from the plant processes. All the vehicles are/will be kept environmentally compliant.
The details are as below:
Vehicular pollution control measures:
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 232 JM EnviroNet Pvt. Ltd.
1. Inspection and maintenance (I&M) programme for vehicles: The first and most important
step towards emission control for the large in-use fleet of vehicles is the formulation of an
inspection and maintenance system. It is possible to reduce 30-40% pollution loads generated
by vehicles through proper periodical inspections and maintenance of vehicles. It should
include testing of various elements of safety, road worthiness and compliance to pollution
norms. Renewal of permits and registration.
2. Emission norms: Emission norms for all categories of petrol and diesel vehicles should be
followed. Bharat stage emission standards are emission standards instituted by Government
of India to regulate the output of air pollutants from internal combustion engine equipment,
including motor vehicles. The standards and the timeline for implementation are set by the
Central Pollution Control Board under the MoEFCC. Following guidelines given in Table - 10.12
are/shall be followed.
Table - 10.12
Emission Standards for Vehicles
Emission norms for Heavy Diesel vehicles
Norms CO (g/kmhr) HC (g/kmhr) NOx (g/kmhr) PM(g/kwhr)
Bharat Stage-IV 1.5 0.96 3.5 0.02
Emission Norms for 2/3 wheeler
Norms CO (g/km) HC+ NOx(g/km)
Bharat stage-II 1.6 1.5
Bharat Stage-III 1.0 1.0
Source: CPCB
3. Appropriate Fuel
Diesel with lower sulphur content should be used
Pre-mixed fuels (petrol and oil mixture) for use of two stroke vehicles
4. Periodical Checking of Vehicles
Vehicles are/will be checked internally or outsourced for the safety check as per the guidelines
and the below mentioned checklist in Table - 10.13. Corrective measures are/shall be taken for
the Unfit vehicles .
Table - 10.13Vehicle Check Sheet for Fitness Certificate
S. No. Particular Checks
1. Tyres Cut, deformation, thread ease wear
2. Steering Gear backlash, kingpin, stub axle, steering free play
3. Engine Noise level 85 dB
4. Suspension Leaf spring position, clamping, shock absorber, bushes, shackle, center bolt
5. Horn Electrical, bulb, pressure horn
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 233 JM EnviroNet Pvt. Ltd.
S. No. Particular Checks
6.Brake Total brake effort > 45%, stopping distance at 30 kmph< 13 mtrs, parking
brake, brake oil leakage
7. Lamps/signals Headlamps, parking, turn signal, top lights, reflectors
8. Embossing of chassis Chassis and engine no. identification plate, month and year of mfg.
9. Speedometer Functioning, speed governors
10. Painting As per Act and rules
11. Wiper Wiper fitment and functioning
12. Body Seating, mudguard, emergency gate, window size, glasses, floor, etc.
13. Electrical Insulations, switches, doom light, spark arrester
14. Finishing Riveting, welding, bonnet, crankcase cover, etc.
15. Road Test Clutch, transmission, axels and performance
16. Others As per specifications
5. Management Measures
Traffic is/will be minimized inside and outside the premises
Keep a check on adulteration of fuel
Proper traffic management system
Concretization of roads
Development of Green belt and plantation around roads and plant periphery as a
mitigative measure
Awareness programmes in the plant and nearby villages regarding speed limit, traffic
rules etc.
10.11 COMPLIANCE OF CREP RECOMMENDATIONS
Following recommendations as mentioned in CREP guidelines of CPCB for Cement Plants is / will
be implemented.
Table - 10.14
S. No. CONDITIONS STATUS
01 The new cement kiln to be accorded NOC/
Environmental Clearance w.e.f 1/4/03 will meet
the limit of 50 mg/Nm3 for particulate matter
emission.
All Pollution Control equipment are meeting the
particulate matter emission level < 50 mg/Nm3.
02 The cement industries will control fugitive
emission from all raw material and product
storage and transfer points by December 2003.
However, the National Task Force will decide
the feasibility for the control of fugitive
emission from limestone and coal storage
areas. The NTF shall submit its
recommendations within months.
Closed storages / silos have been provided for Clinker,
Fly Ash, Gypsum and Cement storage.
Closed unloading hoppers with water sprinkling
arrangement have been provided for unloading of
limestone and coal and pet coke.
Bag filters have been provided at all material transfer
points.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - X of Final EIA / EMP Report
M/s. Shree Cement Ltd. 234 JM EnviroNet Pvt. Ltd.
S. No. CONDITIONS STATUS
All conveyor belts are covered.
All movement area is cemented and sweeping is being
done by vacuum sweeping machine.
03 Industries will submit the target date to
enhance the utilization waste material by April
2003.
Fly ash is used for making of PPC.
Lead Zinc slag of Hindustan Zinc Limited is used as
alternative raw material in place of iron ore.
04 NCBM will carry out a study on hazardous waste
utilization in cement kiln by December 2003.
CPCB and RSPCB permissions have been obtained for
use of Paint sludge, ETP sludge and Phosphate sludge
of automobile industries. CETP Sludge of Pali, Chemical
Gypsum, Tyre chips, Solid mix waste and liquid mix
waste, oil soaked cotton and grinding waste, Oily rags
and incineration ash
05 Cement industries will carry out feasible study
and submit target dates to CPCB co-generation
of power by July-2003.
All kilns are attached with waste heat recovery system.
10.12 CONCLUSION
As discussed, it is safe to say that the proposed expansion project will not be likely to cause any
significant impact on the ecology of the area, as adequate preventive measures will be adopted to
contain various pollutants within the permissible limits. Green belt development around the area
would also be taken up as an effective pollution mitigative technique, as well as to control the
pollutants released from the premises of Shree Cement Ltd.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 235 JM EnviroNet Pvt. Ltd.
CHAPTER - XI
SUMMARY & CONCLUSION
11.1 INTRODUCTION
Shree Cement Limited (SCL) is the largest producer of cement in Northern India with a production
capacity of 25.6 Million TPA. It started its operations in 1985 with 0.6 Million Tonne capacity at
Bangur Nagar, Beawar in Ajmer, Rajasthan and has rapidly expanded its operations to reach the
present production capacity of 25.6 Million TPA. The principal promoter of the company is Bangur
Group, which is a respected business house of India.
SCL has obtained Environmental Clearance for Integrated Cement Plant - Clinker, Cement, Captive
Power Plant, WHRB and D.G Set near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan) from
MoEFCC, New Delhi vide Letter No. J-11011/343/2012-IA-II (I) dated 10th September, 2015.
The company is now proposing for an expansion of Integrated Cement Plant - Clinker (11.2 to 15.0
Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW) along with
Synthetic Gypsum Unit (1560 TPD) and DG Sets (1000 to 2000 KVA) near Village: Ras, Tehsil:
Jaitaran, District: Pali (Rajasthan).
As per EIA Notification dated 14th Sept., 2006, as amended from time to time; the project falls
under Category A , Project or Activity 3 (b) .
Application (Form-1/ToR and Pre-Feasibility Report) for obtaining Environmental Clearance for this
expansion project was submitted to MoEFCC, New Delhi on 24th Jan., 2015.
The project was considered in front of Expert Appraisal Committee (EAC) (Industry- 1) for its First
Technical Presentation (for ToR approval) on 11th Feb., 2015.
ToR Letter was issued by MoEFCC, New Delhi vide letter no. J-11011/343/2012-IA II (I) dated 10th
Feb., 2016. Public Hearing for the project was conducted on 20th April, 2016.
11.2 JUSTIFICATION FOR THE PROJECT
Proposed expansion will be done on additional area available within the plant boundary. The site
for the existing plant was finalized considering the ideal location for the industries. Following
factors were considered while selecting the site for unit of desired capacity:
Availability of limestone in the near-by area.
Total water requirement after the proposed expansion project will be 3500 KLD.
There is no National Park, Wild Life Sanctuary, Biosphere Reserve within 10 km radius of
study area.
No Forest land is involved.
Out of existing plant area i.e. 187.5 ha, about 63.8 ha (34%) is already under green belt/
plantation and additional 14.5 ha will be further developed for this expansion project.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 236 JM EnviroNet Pvt. Ltd.
There is/will not be any kind of major pollution due to the project activity, as the project will
be implemented with environment friendly technology.
Emissions will be maintained within the prescribed limits, as per guidelines.
No wastewater is being/will be generated from the Integrated Cement Plant as the Cement
Plant is based on dry process technology.
No solid waste is being/will be generated from the Cement manufacturing process. The fly
ash generated from Captive Power Plant (CPP) will be reused in manufacturing of Cement.
CREP guidelines for Cement production is being / will be followed.
CPCB guidelines for fugitive emissions is being / will be followed.
11.3 DETAILS ABOUT THE PROJECT
11.3.1 Brief Description of the Project
Brief description about the Project is given in Table - 11.1.
Table - 11.1
S. NO. PARTICULARS DETAILS
A. Nature and Size of the Project
Proposed Expansion of Integrated Cement Plant - Clinker (11.2
to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS
(68 to 90 MW), CPP (180 MW) along with Synthetic Gypsum
Unit (1560 TPD) and DG Sets (1000 to 2000 KVA)
B. Location Details
1. Village Ras
2. Tehsil Jaitaran
3. District Pali
4. State Rajasthan
C. Geographical Extent of the Plant Site
5. Latitude 26o 15 31.6 to 26o 16 45.3 N
6. Longitude 74o 10 53 to 74o 11 48.1 E
7. Toposheet No. 45 J/3, 45 J/4, 45 J/7 and 45 J/8
D. Area Details
1. Plant area
Total plant area is 231.54 ha (which includes 187.56 ha existing
plant area and 43.98 ha additional area within plant boundary);
72.7 ha area is also available outside the plant boundary for
future use.
2. Greenbelt / Plantation area
63.8 ha (34% of the total existing plant area i.e. 187.5 ha)
has already been developed under greenbelt/ Plantation
Additional 14.5 ha will be further developed for this
expansion project.
3. Township Area
Area of the township near village Bagatpura is 40 ha, out of
which 14.5 ha (i.e. 36%) is developed under greenbelt /
plantation area.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 237 JM EnviroNet Pvt. Ltd.
S. NO. PARTICULARS DETAILS
E. Environmental Setting Details (with approximate aerial distance and direction from the plant site)
1. Nearest Town Ras (3.0 Km in N direction)
2. Nearest City Beawar (21.0 Km in SE direction)
3. Nearest National / State HighwayNH - 14 (19.5 Km in SE direction)
SH - 39 (1.5 Km in NE direction)
4. Nearest Railway station Beawar (21.0 Km in SE direction)
5. Nearest Airport Jodhpur (113 Km in W direction)
6.
National Parks, Wild Life Sanctuaries,
Biosphere Reserves, Tiger / Elephant
Reserves, Wildlife Corridors, etc. within
10 km radius
No National Park, Wildlife Sanctuary, Biosphere Reserve, Tiger
/ Elephant Reserve, Wildlife Corridor etc. exists within 10 km
radius of the plant site
7.Reserved / Protected Forests within 10
km radius
Reserved Forest (5.0 Km in SSE direction)
Protected Forest (9.9 Km in SE direction)
8. River / Water Body within 10 km radiusLilri River (Seasonal) (1.5 Km in North direction)
Sukri River (8.0 Km in SSW direction).
9. Seismic Zone Zone-II [as per IS 1893 (Part-I): 2002]
10.Critically Polluted Area as per CEPI -
CPCB
No critically polluted area declared under CEPI as per MoEFCC
Circular dated 15.03.2010 exists within 15 km radius study area
F. Cost details
1. Total Cost of the Project Rs. 755 Crores
2.Cost for Environmental Protection
Measures
Capital Cost - Rs. 51.0 Crores
Recurring Cost - Rs. 1.0 Crores / annum
Source: Pre-feasibility Report
11.3.2 Requirements for the Project
11.3.2.1 Raw Material Requirement
Details regarding quantity of raw materials required, their source along with distance & mode of
transportation for proposed expansion project are given in Table - 11.2 and 11.3.
Table - 11.2
Raw Material Requirement, Source and Transportation for Clinkerization and CPP
S. No. Name of Raw Material
Required Quantity (MTPA)
SourceDistance & Mode of
TransportationExisting Additional
Total after
proposed
expansion
1.Limestone (Clinker
Units and CPP)16.8 5.7 22.5 Captive Limestone Mine
Adjacent to the plant,
Conveyor belts
2.
Laterite
0.504 0.171 0.675
Bhilwara Bhilwara - 190 kms,
Chhitorgarh (Raj) - 200 kms;
Rail and RoadLead Zinc SlagChhitorgarh (Raj) and
other nearby sources.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 238 JM EnviroNet Pvt. Ltd.
S. No. Name of Raw Material
Required Quantity (MTPA)
SourceDistance & Mode of
TransportationExisting Additional
Total after
proposed
expansion
3.
Gypsum
(Mineral, Synthetic,
Chemical & Imported)
0.44 0.22 0.66
Bikaner, Nagaur (Raj), SCL
Units, Gujarat, other
sources & Other
countries
Bikaner - 425 kms, Nagaur
(Raj) - 150 kms
Rail and Road
4. Fly Ash 3.0 1.5 4.5
STPS, Suratgarh; KTPS
Kota; Chabra and other
power plants and other
nearby sources
STPS, Suratgarh - 450 kms;
KTPS Kota - 255 kms, Chabra
- 425 kms
Road
Source: Pre-feasibility Report
Table - 11.3
Raw Materials Requirement for Synthetic Gypsum Unit
S.
No.Name of Raw Material
Existing Quantity
(MTPA)Source
Distance and Mode of
Transportation
1. H2SO4 98% 0.22 Local Market By road
2. Limestone 0.33 Captive limestone mine Covered Conveyor Belt
Source: Pre-feasibility Report
11.3.2.2 Fuel Requirement
Details regarding quantity of fuel required, their source along with distance and mode of
transportation for proposed expansion project are given in Table - 11.4.
Table - 11.4
Fuel Requirement
S.
No.Name of Fuel
Required Quantity (MTPA)
Source of
Materials
Distance & Mode
of
Transportation
Calorific
value
(Kcal./kg)
% Ash%
SulphurExisting Additional
Total after
proposed
expansion
1.
Clinker units -
Indian and
Imported Coal /
Pet Coke / Lignite
1.68/
3.36/3.3
6
0.57/1.14/1.
14
2.25/4.5/2.
92
Reliance, IOCL,
Essar & other
Petrochemical
Refineries,
USA, Swiss,
Saudi Arabia,
Rajasthan etc
Reliance - 750
kms, IOCL-520
kms), Essar -
750 kms &
Swiss, Saudi
Arabia (Kandla
Port) - 650 kms
Rail and Road
7936 /
3890
/6100
0.8 /
9.6 /
41.7
5.5 / 3.5
/0.5
2.
CPP -
Indian and
Imported Coal/
Pet Coke/Lignite
0.5/ 1.0/
0.65Nil
0.5/ 1.0/
0.65
Source: Pre-feasibility Report
11.3.2.3 Other Basic Requirement
Other basic requirements for the proposed expansion project are given in Table - 11.5.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 239 JM EnviroNet Pvt. Ltd.
Table - 11.5
Basic Requirements for the Project
S. No. Particular Requirement Source
1. Water (m3/day) 3500 Ground Water
2. Power (MW) 158.9Captive Power Plant, WHRB, Grid and D.G Sets
(for backup)
3. ManpowerRegular - 1460
Contractual - 1951
Unskilled/ semi-skilled manpower from local area
and skilled from outside/local.
Source: Pre-feasibility Report
11.4 PROCESS DESCRIPTION
11.4.1 New Clinker Unit (Unit-XI) and Cement Unit Manufacturing Process
Cement Plant is based on Dry Process Technology for Cement manufacturing with Pre-Heater and
Pre- Calciner Technology. The type of cement being manufactured is OPC & PPC.
The cement manufacturing process largely comprises of the following steps:
Transportation of crushed limestone from the mine site.
Pre-blending of crushed limestone by Stacker & Reclaimer.
Grinding-cum- Drying of Raw Materials and Coal/Petcoke in VRM
Homogenization of raw meal in a blending silo.
Clinkerization of the raw meal in a rotary kiln with preheater, calciner and Cooler.
Finish Grinding, storage and packing of cement.
11.4.2 Waste Heat Recovery Power Plant
For re-utilization of the wasted heat from the expelled gases of Pre-Heaters (PH) and Air
Quenched Coolers (AQC) in each Unit. M/s. Shree Cement Ltd. (SCL) has proposed to
expand the capacity of Waste Heat Recovery Boiler from 68 to 90 MW.
Steam generated from each unit is being / will be combined and fed to steam turbine for
electricity generation.
11.5 DESCRIPTION OF ENVIRONMENT
11.5.1 Presentation of Results (Air, Noise, Water & Soil)
Baseline study of the study area (Composite for plant & mine) was conducted during Summer
Season (March to May, 2015). Ambient air quality monitoring has been carried out at 12 stations in
the study area on 24 hourly basis. The concentration of PM2.5 ranges between 20.6 to 38.1 g/m3,
PM10 ranges between 56.2 to 81.0 g/m3, SO2 ranges between 5.2 to 9.8 g/m3 and NO2 ranges
between 14.2 to 26.3 g/m3.
Ambient noise levels were measured at 12 locations around the plant and mine site. Noise levels
varies from 50.2 to 63.2 Leq dB(A) during day time and from 39.4 to 57.1 Leq dB(A) during night
time.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 240 JM EnviroNet Pvt. Ltd.
The ground water analysis (Composite for plant & mine) for all the 9 sampling stations shows that
pH varies from 7.08 to 7.56, Total hardness varies from 360.80 to 581.12 mg/l, Total dissolved
solids vary from 978 to 1489 mg/l.
Soil monitoring (Composite for plant & mine) was carried out at 9 locations and the analysis
results show that soil is neutral to moderately alkaline in nature, pH value ranging from 7.26 to
7.58, with organic matter from 0.40% to 0.67%. Soil texture is Sandy Clay. Total nitrogen ranges
from 174.89 kg/ha to 223.98 kg/ha, indicates that nitrogen is in sufficient amount in this soil.
11.5.2 Biological Environment
Flora: Most common species found in the area are Anogeissus pendula (Dhokra), Acacia catechu
(Khair), Acacia nilotica (Babool), Azadirachta indica (Neem), Ziziphus mauritiana (Ber), Prosopis juliflora
(Kikar/Vilayati Babul), Phoenix sylvestris (Khajur), Calotropis procera (Aak), etc.
Fauna: Commonly found species in the study area are Bubulcus ibis (Cattle Egret), Columba livia (Blue
Rock Pigeon), Corvus splendens (Common Crow), Boselaphus tragocamelus (Nilgai), Rana tigerina
(Indian Bull Frog), Buthus sp. (Scorpion)etc.
11.5.3 Socio-Economic Environment
The population as per 2011 Census records is 56332 (for 10 km radius buffer zone). The
Demographic profile of the study area shows that total no. of household are 1163, 3630 and 6551
respectively in primary, secondary and outer zone. Sex ratio is 951, 936 and 967 (females per 1000
males) observed in primary, secondary and outer zone respectively.
SC population distribution is 777, 3492 and 5821 respectively in primary, secondary and outer zone.
ST population distribution is 2722, 19 and 769 respectively in primary, secondary and outer zone
respectively. Literacy rate is 35.05%, 53.74% and 56.1% in primary, secondary and outer zone
respectively. Average household size is 4.96.
11.6 ANTICIPATED ENVIRONMENTAL IMPACTS AND MITIGATION MEASURES
Anticipated environmental impacts due to operation of the proposed expansion project along
with mitigation measures are given below:
Discipline Anticipated Impact Mitigation Measures
Construction Phase
Air Increase in dust and NOx concentration
due to Leveling activity and Heavy
vehicular movement
Sprinkling of water in the construction area and on
unpaved roads.
Proper maintenance of vehicles will be done. Use of
vehicles meeting PUC norms
Noise Increase in noise level due to
Construction Equipment
Equipment will be kept in good condition to keep
the noise level within 90 dB (A).
Workers will be provided necessary protective
equipments e.g. ear plugs, earmuffs.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 241 JM EnviroNet Pvt. Ltd.
Water Increase in suspended solids due to soil
run-off during heavy precipitation due to
Loose soil at construction site
Adequate drainage system for runoff water during
construction phase.
Operation Phase
Air Increase in concentration of Particulate
Matter Emissions
Better maintenance and installation of pollution
control equipment like ESP / Bag House / Bag Filters.
Covered storage facilities for raw material &
product.
All the roads inside the plant premises will be
concreted.
Water sprinkling to reduce the PM emission level.
CPCB and CREP guidelines are being / will be
followed.
Increase in NO2 emissions Low NO2 burners
Noise Increase in noise level within the plant
areaEquipment to be installed is designed to conform to
occupational noise levels prescribed by regulatory
agencies.
Earmuffs/ Earplugs will be provided to persons
working in high noise zone.
Properly insulated enclosures will be provided to
equipments making excessive noise.
Greenbelt development/ plantation will help in
attenuating noise.
Water Generation of waste water Domestic wastewater generated from plant and
colony is being / will be treated in STP and treated
water is being / will be utilized for greenbelt
development / plantation.
RO reject water is being / will be used in Synthetic
Gypsum manufacturing process, ash quenching and
dust suppression.
Soil Degradation of soil quality due to
settling of air borne dust
Use of efficient pollution control systems
Maintained proper stack height
Soil samples are being/ will be collected periodically
and soil quality is being/ will be tested.
Biological Environment
a. Terrestrial
Ecology
Positive as greenbelt of appropriate
width has been developed and
maintained by SCL in the area
-
b. Aquatic Ecology No impact as no effluent is being / will
be discharged outside the plant
premises
-
Socio-economic
Environment
Overall development of the area in
respect of the infrastructure
development, educational growth,
health facilities etc.
-
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 242 JM EnviroNet Pvt. Ltd.
11.7 ENVIRONMENTAL MONITORING PROGRAMME
Details of the environmental monitoring schedule / frequency, which will be undertaken for
various environmental components, as per conditions of EC / CTE / CTO are given in Table - 11.6.
Table - 11.6
Post Project Monitoring
S. No. Description Frequency of Monitoring
1. Meteorological Data Hourly
2. Ambient Air Quality Continuous monitoring
3. Stack Monitoring Continuous monitoring and monthly
4. Water Quality Pre- monsoon and Post-monsoon
5. Noise Level Monitoring Monthly
6. Medical Checkup of Employee Yearly
11.8 ADDITIONAL STUDIES
Additional Studies conducted as per ToR Letter no. J-11011/343/2012-IA II (I) dated 10th Feb., 2016,
issued by MoEFCC, New Delhi are Hydro-geological Study & Rain water Harvesting Plan and Risk
Assessment & Disaster Management Plan.
11.9 PUBLIC CONSULTATION
Public Hearing was conducted on 20th April, 2016 at 3:00 PM at Office, Sub Divisional Officer,
Jaitaran, District - Pali (Rajasthan). Major issues raised during Public hearing were of Employment,
Environment related, plantation, education, ESC activities. Detailed action plan for the same has
been prepared.
11.10 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN
There is being/ will be no major risk involved due to proposed expansion project. Proper
precautionary measures are being/ will be taken to minimize risks. Personal Protective Equipments
(PPEs) will help to minimize the health hazards and accidental casualties. So it is safe to say that
there is being/ will be no major risk involved due to the proposed expansion project.
11.11 PROJECT BENEFITS
The proposed expansion project will help in combating the growing demand of cement in the
market & hence will help in the economic growth of the country. Shree Cement Ltd. Is/will be
actively involved in the ESC activities in the nearby villages of the project site. Infrastructure
development in the nearby villages, creating educational facilities, empowering women through
self-help groups, gainful employment for rural, health awareness programmes & surgical camps,
assistance in social forestry programmes in the area, are some of the activities further to be
undertaken under ESC plan for the development and upliftment of the society. Company has
proposed Rs. 18.87 Crores to be spent in next ten years in ESC activities.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 243 JM EnviroNet Pvt. Ltd.
11.12 ENVIRONMENT MANAGEMENT PLAN
The major sources of pollution in Integrated Cement Plant are Particulate Matter. Air pollution is
the major concern to be looked upon for the project activity. No major water, noise and soil
pollution is envisaged from the project activity. Various mitigation measures have been proposed
to take care of the environment in respect of air, water, noise, soil and the green cover of the
plant site and nearby villages.
Particulars Details
Air Quality Management Bag filters will be provided to control dust emitted from various dust generating
points in the plant and at all material transfer points.
Dry fly ash will be transported in closed tankers.
Clinker and Fly Ash will be stored in silos and Gypsum in covered sheds.
Greenbelt will be developed around/ within the premises of the plant site to arrest
the fugitive emissions.
Unloading of trucks will be carried out with proper care avoiding dropping of the
materials from height.
Sprinkling of water will be done along the internal roads in the plant in order to
control the dust arising due to the movement of vehicles.
Proper maintenance of vehicles will be done to reduce gaseous emissions.
Low NO2 burners
Regular ambient air quality and stack emission monitoring is being carried out as
per CPCB / SPCB norms to ensure that ambient air quality standards are being met
all the time.
Water Management No waste water is being / will be generated from the Cement manufacturing
process.
Domestic wastewater generated from plant and colony is being / will be
treated in STP and treated water is being / will be utilized for greenbelt
development / plantation.
RO reject water is being / will be used in Synthetic Gypsum manufacturing
process, ash quenching and dust suppression.
Rain water harvesting is being/ will be practised inside the plant and colony
premises.
Noise Management Proper maintenance, oiling and greasing of machines at regular intervals is
being/ will be done to reduce generation of noise.
Personal Protective Equipment like earplugs and earmuffs are/ will be provided
to the workers exposed to high noise level.
Installation of compressors in closed building.
Green Belt has been developed all along the plant boundary and will be further
enhanced.
Regular monitoring of noise level is being/ will be carried out and corrective
measures in concerned machinery will be adopted accordingly to the possible
extent.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XI of Final EIA / EMP Report
M/s. Shree Cement Ltd. 244 JM EnviroNet Pvt. Ltd.
Particulars Details
Solid & Hazardous Waste
Management
No solid waste is being/ will be generated from the cement manufacturing
process.
Dust collected from air pollution control equipment is being/ will be totally
recycled back into the process.
Ash generated from CPP is being/ will be utilized in manufacturing of cement.
STP sludge is being/ will be utilized as manure for green belt development/
plantation.
Hazardous waste like Paint Sludge, Automobile ETP Sludge, Phosphate Sludge,
CETP Sludge of Pali etc. generated by other units is being/ will be utilized as
AFR.
Used oil is being/ will be generated as hazardous waste will be sold to CPCB
authorized recycler.
Green Belt Development /
Plantation
Out of the total existing plant area (i.e. 187.56 ha), about 63.8 ha (i.e. 34% of
the total existing plant area) has already been developed under green belt /
plantation.
Additional 14.5 ha (33 %) will be further developed under green belt/ plantation
for this proposed expansion in order to reduce dust and noise pollution levels
& to increase aesthetic beauty of the area.
Presently there are 165311 numbers of saplings in 63.8 hectare area.
SCL is now proposing to develop 1200 trees and shrubs/ hectare in new
proposed area.
Species proposed to be planted are Azadirachta indica (Neem), Delonix regia
(Gulmohar), Dalbergia sisso (Seasam), Pongamia pinnata (Karanja) etc.
11.13 OCCUPATIONAL HEALTH AND SAFETY
To control and minimize the risks at workplace, Shree Cement Ltd. has implemented Health,
Safety and Environment Policy with the following objectives:
To prevent hazards
To provide safe and healthy environment to all the employees.
The company, therefore, has adopted the policy for the purpose of creating and maintaining safe
and healthy environment.
11.14 CONCLUSION
As discussed, it is safe to say that the proposed Expansion project is an environmental friendly
project, as adequate preventive measures will be adopted to maintain the various pollutants
within permissible limits. Green belt development around the area would also be taken up as an
effective pollution mitigation technique.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 245 JM EnviroNet Pvt. Ltd.
CHAPTER-XII
DISCLOSURE OF THE CONSULTANT ENGAGED
12.1 DISCLOSURE OF THE CONSULTANT ENGAGED
J.M. EnviroNet Pvt. Ltd. (JMEPL) has prepared this Final EIA / EMP Report along with preparation of
Land Use / Land Cover Maps of the core and buffer zone.
Brief description of the company is given as under:
J.M. EnviroNet Pvt. Ltd., one of the companies of JM Group, was established in the year 1993. JM
in the name of the Company is derived from the name of Lord Shiva - the Temple of Jharkhand
Mahadev (JM). The Temple is located at Queens Road, Vaishali Nagar, Jaipur.
The Registered office of JMEPL is at 7-CH-10, Jawahar Nagar, Jaipur. Its Delhi-NCR Corporate office
is at SCO-16, Sector 10A, Gurgaon (Haryana).
J.M. EnviroNet Pvt. Ltd. is accredited with ISO-9001: 2008 for EIA Division. EIA Division is also
approved by National Accreditation Board for Education & Training (NABET) formerly NRBPT
(Quality Council of India), Certificate no. NABET/EIA/1013/002 dated 17thMay 2010.
J.M. EnviroNet Pvt. Ltd. is listed at serial no. 99 of the List of Accredited EIA Consultant
Organization displayed on MoEFCC website
(http://www.qcin.org/nabet/EIA/documents/Accredited%20consultants.pdf), updated as on 08th
June, 2016.
JMEPL is offering Environmental Consultancy Services in various sectors viz Industrial Projects /
Chemical Industries / Cement Plants / Thermal Power Plants / Mining. Projects/ Coal Washery
Project/ Real Estate Projects / Distilleries / Steel Plants/Chemical Fertilizers/Mineral Beneficiation
etc.
In the Mining sector, JMEPL is covering mines of minerals viz. Limestone, Bauxite, Chromite, Coal,
Zinc, Copper, Gypsum, Soapstone, Iron and Manganese ore, Clay, Silica Sand, Feldspar, Quartz etc.
JMEPL has a highly qualified team of Subject Experts. As Faculty Heads of the EIA Division, we
have Retd. General Managers of the Reputed Cement Companies, Ex-Head EIA Division of big
Business Group, STP & ETP Designing Experts, Retd. Mining and Geology Experts with vast
experience in their respective fields.
JM Group s business is spread over 22 States viz.: Andhra Pradesh, Kerala, Gujarat, Maharashtra,
Orissa, Tamil Nadu, Goa, Jammu & Kashmir, Himachal Pradesh, Punjab, Haryana, Delhi, Rajasthan,
Uttar Pradesh, Madhya Pradesh, Chhattisgarh, Assam, West Bengal, Karnataka, Jharkhand, Bihar
and Uttarakhand.
Proposed Expansion of Integrated Cement Plant- Clinker (11.2 to 15.0 Million TPA), Cement (8.8 to 13.2 Million TPA), WHRS (68 to 90 MW), CPP (180 MW),
Synthetic Gypsum (1560 TPD) & DG Sets (1000 to 2000 KVA)
Near Village: Ras, Tehsil: Jaitaran, District: Pali (Rajasthan)
Chapter - XII of Final EIA / EMP Report
M/s. Shree Cement Ltd. 246 JM EnviroNet Pvt. Ltd.
The JM Group has its own Environmental Laboratory at Gurgaon (Haryana) & Raipur
(Chhattisgarh) approved under EPA (Environment Protection Act) from the Ministry of
Environment & Forests, Govt. of India, New Delhi and by the National Accreditation Board for
Testing and Calibration Laboratories, Govt. of India (NABL).
Besides this, its MoEFCC and NABL approved Environmental Laboratory of JM Group is also
providing Analytical Laboratory Services of various elements and environmental parameters.
Annual monitoring as per MoEFCC/CPCB/SPCB guidelines, Risk Assessment and Disaster
Management Plan, consultancy for Rain Water Harvesting Plan, detailed Hydro-geological Study,
preparation of Environmental Statement Reports (Environmental Clearance Compliance
Conditions) etc. are amongst the various other consultancy services offered by the Company.
*Additional study i.e. Hydro-geological Report along with Rain Water Harvesting has been prepared
by, Mr. Pavan Gupta, Chief Consultant (Ground Water),Associate Engineers & Consultants, 4/8,
Malviya Nagar, Jaipur (Raj) - 302017.
O(L
SCLfRas/lJnit-IX /2016-20171
~SJL- __Date: 05/05/2016
Regd. A.D.
CPM CELL
File No. - C-144
To,
The Member Secretary,
Rajasthan State Pollution Control Board
4, Institutional Area, Jhalana, Doongri,
.IAIPUR - 302004 (Raj.)
Sub:- Compliance of conditions of consent to operate granted by the board under the Air (Prevention & Control of Pollution) Act-1981 & Water (Prevention & Control
of Pollution) Act-1974 for Mis Shree Cement Limited; Unit-IX at RAS, Bhimgarh, Teh: .Iaitaran, District-Pali (Rajasthan).
Ref: - Letter F(CPM)/Pali(Jaitaran)/1024(J)/20J3-2014/S05S-S061 dated 16/02/2016
Dear Sir.
Please find herewith the point-wise monthly compliance report of various conditions of consent to operate as per the letter granted by board section 25/26 of the Water
(Prevention & Control of Pollution) Act and under section 21 (4) of Air (Prevention & Control of Pollution) Act-1981 for Mis Shree Cement Ltd; Unit-IX, situated near
r>; Village' RAS Bhimgarh Teh Jaitaran District Pali (Raj ) for the month of Anril 2016. , -Sr. Condition Compliance Status
No.
I. That this Consent to operate is valid for a period from 16/02/2016 to 31/0112019 Noted.
2. That this consent is granted for manufacturing! producing following products! by products or
carrying out the following activities or operation I processes or providing following services
with capacities given below.Noted.
I Particular I Tvne I Quantitv with Unit II CLINKER Product I 2 MTPA I
3. That this consent to operate is for existing plant, process & capacity and separate consent to Complying with. There is no change/ addition/modification/alteration in process or
establish / operate is required to be taken for any addition/modification/alteration in process or change in capacity or fuel.
chance in caoacitv or chanze in fuel.
4. That the quantity of effiuent generation along with mode of disposal for the treated effluent Total domestic waste water generation by the unit is <lSKLD and waste water IS
shall be as under: treated in STP. Treated water is used for greenbelt development.
Type of Maximum effluent Recycled Disposal quantity of effluent
Ieffluent generation (KLD) Quantity of (KLD) and mode of disposal
effluent (KLD)
Domestic 15.000
sewage 15.000 NIL Plantation/other uses Within
I premises.
5. That the sources of air emissions along with pollution control measures and the emission Stack emission results are given as Annexure 1.
standards for the nrescribed parameters shall be as under.
Source of Air Emissions Pollution Control Prescribed
Measures Parameter Standard
CLINKER COOLER (800000 ESP Particulate Matter 50mgfNm'
M'/HOUR)
COAL MILL Bag House Particulate Matter 50 mg/Nrrr
(185000 M'/HOUR)
RAW MILLS & (1350000 Bag House Particulate Matter 50mg/Nm
M'/HOUR)
6. That the Ras New Cement Unit (Unit IX) plant will comply with the standards as prescribed Complying with. Monitoring results are given as Annexure I.
vide MOEF notification No. GSR 826 (E) dated 16'" November. 2009 with respect to National
Ambient Quality Standards.
7. That the domestic sewage shall be treated before disposal so as to conform to the standards Complying with. Monitoring results are given as Annexure 1.
prescribed under the Environment (Protection) Act- I 986 for disposal into Inland Surface
Water. The main parameters for regular monitoring shall be as under:
Parameters Standards
Total Suspended Solids Not to exceed 100 mg/I
pH Value Between 5.5 to 9
Total Residual Chlorine Not to exceed 1.0 mg/I
Total Kjeldahl Nitrogen ( as N ) Not to exceed 100 mg!l
Biochemical Oxygen Demand (3 Not to exceed 30 mg/I
days at 27°C)
Sulphide ( as S ) Not to exceed 2.0 mg/I
Chlorides Not to exceed 1000 mgll
Oil and Grease Not to exceed 20 mg/l
Chemical Oxygen Demand Not to exceed 250 109/I
8. Thai this Consent to Operate is being issued for production of clinker up to 2.0 MMTPA from Noted.
unit no-IX onlv.
9. That the total project cost as submitted in c.A. certificate is Rs.S80.12 crores which includes Noted.
Page 1 of 4
o(c
Page 312
10.
That no ground water in excess of 4000 KLD shall be abstracted without ptior permission from
the State Board and CGW A.
the cost of land, building, Plant and Machinery.
That the Charter of corporate responsibility for Environment Protection specified for cement
plants &Power Plant shall be complied.
II. That for the control fugitive emission guidelines I code of practice as issued by CPCB will be
followed.
Sr.
No.
CREP CONDITION ACTION PLANNED
All Pollution Control
Equipments are designed to
meet the limit of 50
mg,lNm3 for particulate
matter emission,
Closed storages / silos for
Clinker, and Cement are
provided.
Water spray arrangements
on raw materials like
limestone and coal I pet
coke are provided.
Bag filters arc installed at
all material transfer points.
Lead zinc slag is used III
place of laterite and PCI
coke is used in place of
coal. Paint sludge. ETP
sludge and Phosphate
sludge of automobile
industry are used.
I. The new cement kiln to be accorded
NOel Environmental Clearance w.e, f
y.I03 will meet the limit of 50 mglNm3
for particulate matter emission.
Hazardous wastes arc
utilized as per the CPCB
guideline.
2. The cement industries will control
fugitive emission from all raw material
and product storage and transfer points by
December 2003. However. the National
Task Force will decide the feasibility for
the control of fugitive emission from
limestone and coal storage areas. The
NTF shall submit its recommendations
within months.
Attached with WHRS.
Complying with CPCB guidelines to conrrol fugitive emission. ~
Fugitive emission (~glM3) inside the plant premises in material handling area is t
as Annexure I.
3. Industries will submit the target date to
enhance the utilization waste material by
April 2003.
12. That the particulate emissions from stack of various sections of cement plant shall Not exceed
50mg/NM3.
4. NCBM will carry out a study on
hazardous waste utilization in cement kiln
by December 2003.
13. That the industry shall maintain continuous real time monitoring system at the Kiln stack to
measure the emission levels of particulate matter, SOx. and NOx, and at coal mill and clinker
cooler for particulate matter.
Cement industries will carry out feasible
study and submit target dates to CPCB
co-generation of power by July-2003.
CEMS have been installed for continuous monitoring of SPM, S02 and NOx at the
stack of Kiln, Coal mill and clinker cooler.
5.
Complying with <50 mglNm3
14. That the industry shall provide & maintain adequate dust collection and extraction System to
control fugitive dust emission at coal crusher and all transfer points.
Unit has been installed adequate pollution control measures at different locations list
is liven below:
S. No. Source Pollution Control Measures
Covered Unloading point1. Coal Unloading
Covered unloading and water spray at
crusher
2. Limestone Unloading
3. Material Transfer Point
4. Petcoke I Coal Storage
5. Limestone Storage
6. Clinker Storage
7. Con veyor Belt
8. Clinker Cooler
9. Raw Mill+Kiln
10. Coal Mill
II All Silo
Agreed.
Dust Collector
Open Storage
Silo + Open Storage
Silo
Covered
RABH (Reveres Air Bag House)
ESP
Bag House
Dust Collector for silo venting
15. That no additional source of air emission shall be installed without prior Permission from the
State Board.
16. That the recommendations of the policy briefs related to human health risk due to Cement dust
exposures shall be complied with.
Complying with recommendation of the policy briefs related to human healtl· ...-:...,.I.:
due to cement dust exposures
17. That the power supply to the production/process shall be interlocked with the pollution control
equipment's that in the event of non -functioning of the pollution Equipment the production
process stops automatically.
Interlocking has been provided.-
18. The industry shall comply with the MoEF, Government of India, 14th Notification dated
September 1999 with till the date amendments relating to fly ash management And shall
provide relevant details to the state Board, MoEF, Government of India.
Complying with.
• Unit - IX is clinker unit
• Fly ash is used for making the ppe in Cement unit.
• Fly ash generated in captive power plant is being utilized for cement
manufacturing.
19. That the total fresh water consumption of unit no- IX after enhancement in production capacity
shall not exceed 245KLD. The water requirement of245.00 KLD shall be sourced from ground
water and mine pit water.
• Complying with.
20. That the total fresh water requirement of the entire plant shall 110t exceed 4346 KLD' out of
which 4000 KLD shall be met from ground water and rest from rain water collected ill the
mine pits.
• Total water consumption for entire project is <4346KLD last three month water
consumption data given below.
Month
Januarv
February
March
Water consumotion KL
68613
63325
64726
1000 KLD and 200 KLD on 23/05120 I I.CGWA renewed the NOC for 2800 KLD,
12/07/2013 & 11102114 respectively.
21. Noted.
Page 2 of 4
Page 313
22. That the industry shall comply with the conditions imposed in NOC issued by COW A for the Noted.
abstraction of ground water vide letter dated 23/05/2011,12/07/2013 and 1110212014.?' That water meters shall be maintained at all the bore wells to measure the daily water All water sources are equipped with water meter and record are maintainedc »,
abstraction and logbook shall be maintained at daily basis.
24. That no industrial effluent will be discharged within or outside the factory premises in to a The cement manufacturing is dry process; hence no effiuent is discharged.
stream or well or sewer or on land.
25. That the domestic sewage for the entire complex shall not exceed to 200 KLD. The treated Total domestic waste water generation by the entire complex is <200 KLD and waste
domestic sewage from the STP shall be used for green belt development within the nremises. water is treated in STP. Treated water is used for greenbelt develooment.
26. That the industry shall comply with the provisions of Hazardous waste (Management, handling Complying with.
and Trans-boundary Movement) Rules, 2008 and daily record of waste generation and its
disposal shall be maintained.
27. TItat the industry shall canyout effluent sampling/stack monitoring/ambient air quality Noted.
monitoring and submit quarterly report from the state Board laboratory/ laboratory recognized
by Ministry of Environment & Forests (MoE&Fl,Govemment oflndia.
28. That suitable flow measuring devices/ meters on the intake source of water, inlet and outlet of All water sources are equipped with water meter and record are maintained
effluent treatment/ sewage treatment plant shall be installed and maintained. Daily record of
Water consumption, effluent generation and it's treatment and utilization shall be maintained.
29. That suitable measure for rain water harvesting water shall he taken. Industry has been developed rain water collection pits at the following locations to use
for plant & mining activities and to recharge the ground water.
So. Structure Water storage
Caoacitv in KL
I. Harvesting Pit-I at Mines 650000
2. Harvestiuu Pit-2 at Mines 40000
". Harvestin ' Pit-S near plant 'ate 147000 I
4.Harvesting Pit,4 in Colony near ViiI.
40000Bhagarpura
Total water requirement entire Ras project (Cement. Power, Mine and Residential
colony) is 4380 KLD.
CGWA have been granted permission to withdraw 4000 KLD ground water.
The balance 380 KLD water will be used from the rain water collected in above
pits.
30. That all the conditions imposed by MoE&F, New Delhi vide Letter noJ-1I01l/34312012-IA- Complied with
11(1)dated 10/0912015 while issuing EC to your project shall be complied.31. That all the conditions imposed vide letter no. F(CPM)/Pali(Jaitaran)1I 024( I)12013- Complied with.
I201411392-1396 dated 20/0512013 and F(CPM)/Pali(Jaitaran)/1 024( I)/20 13-20 14/432-435
. dated 30/0412015 shall be complied.
32. That this consent to operate is being issued in supersession to consent to operate Issued vide Noted.
letter no. F(CPM)lPali(Jaitaran)l1 024 (I )120 13-20 14/432-435 dated 30/0412015.
33. That the industry shall submit quarterly compliance report of all the above Conditions to the Complied with.
State Board.
34. TItat this revised consent letter shall supersede the earlier consent letter no F(CPM)/Paii Noted.
(laitaran)1I 024(1) 120 13 -2014 18022-8025 dated 16/0212016
35. That, notwithstanding anything provided hereinabove, the State Board shall have power and It is Board'sjurisdiction.
reserves its right, as contained under section 27(2) of the Water Act and under section 27(6) of
the Air Act to review anyone or all the conditions imposed here in above and to make such
variation as it deemed fit for the purpose of Air Act & Water Act,
36. That the grant of this Consent to Operate is issued from the environmental angle only. and does Yes, the grant of this Consent to Operate is issued from the environmental angle only.
not absolve the project proponent from the other statutory obligations Prescribed under any and does not absolve the project proponent from the other statutory obligations
other law or any other instrument in force. The sole and complete Responsibility to comply prescribed under any other law or any other instrument In force. The sole and
with the conditions laid down in all other laws for the time-being in force. rests with the complete responsibility, to comply with the conditions laid down in all other laws for
mdustrv/ unitJ project nrononent. the time-bein ' in force, rests with the indusrrv/ unit! oro iect nrooonent.
37. That the grant of this Consent to Operate shall not, in allY way, adversely affect or jeopardize II is Boards jurisdiction,
the legal proceeding, if any. instituted in the past or that could be instituted Against you by the
State Board for violation of the provisions of the Act or the Rules made Thereunder.
This is for your kind information please.
~ Thanking you,
Yours faithfully,
~.~ (Rakesh Bhargava)
~~ViCC President (Environment)
Copy to: -The Regional Officer (Regional Office) Rajasthan Board for Prevention & Control of Pollution, A-6, Mandia Road, Industrial Area, Near
Pali Urban Co-Operative Bank, PALI- MARWAR-306401 (RAJ.)
Page 3 of 4
Page 314
Unit-IX, monthly monitoring report: April-2016
Annexure I
I Ambient Air Quality Monitoring Data' -Ambient Air Quality Monitoring (All Values in J.lg/m.l)
Location Date PM-2.S PM-IO S02 NO, Location Date PM-2.5 PM-IO S02 NO,
4-Apr-16 23 36 8.7 10.7 4-Apr-16 30 36 84 10.6
6-Apr-16 21 33 9.3 10.6 6-Apr-16 26 41 9.3 10.0
8-Apr-16 17 42 8.2 10.2 Plant 8-Apr-16 19 41 8.0 10.0
P(nnt 12-Apr-16 19 32 8.6 11.0 boundary 12-Apr-16 23 41 8.5 10.9
boundary near 15-Apr-16 19 41 8.6 10.5 towards 15-Apr-16 31 42 8.5 10.3Main Gate
20-Apr-16 19 38 8.6 11.0 Stacker & 20-Apr- I6 26 43 8.5 10.9
22-Apr-16 21 44 7.9 104 Reclaimer 22-Apr-16 36 32 7.9 10.3
27-Apr-16 23 44 8.6 11.1 27-Apr-16 30 38 8.8 ILl
Average 20.3 38.7 8.6 10.7 Average 27.6 39.3 8.5 10.5
4-Apr-16 20 39 9.2 11.1 Plant boundary 4-Apr-16 21 37 8.8 10.7
6-Apr-16 20 39 10.0 11.3 towards- 6-Apr-16 19 45 9.3 11.1
8-Apr-16 25 39 8.7 10.6 Khera & 8-Apr-16 28 42 8.5 10.1
PlantI2-Apr-1 6 21 40 9.2 11.5 Jawangarh
I2-Apr-1 6 30 42 8.7 II I
boundary near 15-Apr-16 23 46 9.2 10.8 15-Apr-16 20 42 8.7 104Mess 20-Apr- I6 20 41 9.2 11.6 20-Apr-16 21 45 8.7 11.0
22-Apr-16 26 41 8.5 10.9 22-Apr-16 20 20 8.1 104
27-Apr-16 19 42 9.3 11.7 27-Apr-16 27 41 94 11.2
Average 21.8 40.9 9.2 11.2 Average 23.3 39.2 8.8 10.8
2. Sta ck EmiSSIOn Monitoring Data:-
Source Of Air Emission Pollution Control Prescribed Parameter Date Monitored Value in Monthly Average
Measures (mg/Nrn") values of Opacity
Meter (mg/Nmj')
Raw Mill & Kiln RABH Particulate Matter 15.04.2016 18 19
Coal Mill Bag House Particulate Matter 18.04.2016 14 15
Clinker Cooler ESP Particulate Matter 18.04.2016 12 13
3. STP Treated Water Quality: - Date: - 18.04.2016
S.No. Parameters Standards Results
I Total Suspended Solids mgll Not exceed 100 mgll 60.1
2. pH Value Between 5.5 to 9.0 7.2
3. Oil & Grease mgll Not exceed 10 mg/l 0.1
4. Total Residual Chlorine Not exceed 1.0 mgll 0.3
5. Amonical Nitrogen (as N) Not exceed 50 mg/l 16.3
6. Biochemical Oxygen Demand (3 days at 27°C) mgll Not exceed 30 rng/l 10.3
7. Sulphide (as S) Not exceed 2.0mgll 0.3
8. Chlorides Not exceed 1000 mgll 73.5
9. Free Available Chlorine Not exceed 0.5 mgll NA
10. Chemical Oxygen Demand mg/l Not exceed 250 mg/l 80.5
uaitive mISSlOn:-
S. No. Location Gypsum Storaze Lime stone stock pile Coal storaze area Fly ash silo Packing Plant
I NOIlllS 5000 5000 2000 5000 5000
2 Date 1404.20 I6 14.04.2016 14.04.20 I6 14.04.2016 19042016
3 April-2016 3925 3689 1256 3600 4100
Monitored By
~Girdhari Lal Yadav
(Officer Environment)
Page 4 of 4
••
Page 315
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
1
CHAPTER 1
EXECUTIVE SUMMARY
Project : Groundwater Resources Evaluation & Rainwater
Harvesting System Development Studies.
Promoters : M/S SHREE CEMENTS LTD, BEAWAR, RAJ.
Conducted by : ASSOCIATE ENGINEERS & CONSULTANTS
Possible sources : Subsurface & Rainwater in the plant & Mines
Area.
Investigation
Methodology :
• Surface Hydro geological studies mining lease & plant area (Core Zone)
• Surface Hydro geological studies for Buffer zone (10 Km radius).
Coverage: (a) Approx. 7.5 Sq. Km of mining lease, 3.042 Sq. Km of Plant & 0.4 Sq.km colony area (Core
Zone)
(b) Approx. 10 Km radius (Buffer Zone)
Findings:
∗ The regional water level ranges between 7m. to 22m. below ground level during the post monsoon period and
during pre monsoon water levels are 15m to 30m below ground level.
∗ Based on results of hydro geological survey conducted in the area, it appears that ground water occurs in
water table condition in weak zones of medium hard & hard rock. In the investigated area, thickness of top soil
is very less generally not more than 6 to 8m in plant area & no Top Soil is found in Mineralised area of Mining
Lease.
∗ For buffer zone (10 km radius) total recharge due to rainfall & irrigation return flow at study year rainfall works
out to be 32.87 mcm/annum. Total discharge works out to be 12.81 mcm/annum & stage of development is
38%.
∗ The area of core zone is under safe category and has surplus exploitable ground water potential, indicating
mining activity has not affected its long-term ground water recharge and its ground water resources. No
stream will be encountered during the mining activity which will require any diversion, and will not affect
surface water resources.
∗ Due to hard, crystalline and chemically resistant nature of limestone the water stored in the mining pit
remains unpolluted and free from any toxic constituents. The overburden, mostly composed of thin alluvial
material also does not contribute any pollutants from its waste. The waste dumps are located in such a way
that there are no hindrances to flow of water bodies and streams.
Page 321
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
2
∗ There is no possibility of any land subsidence due to heavy pumping or mining as the rocks are hard, compact,
impervious and crystalline, which can be stand of its own. Beside that there is no heavy pumpage for ground
water extraction.
∗ The mining activity, as per the conceptual plan is proposed to be confined to an area of 450 Hect and will be
up to depth of 123 m.at the end of the mine about 190 hectare area will be left as water recharge pit or as a
source of water supply containing about 0.760 mcm of water.
∗ To reduce groundwater extraction, some measures have already been taken by the management. Firstly,
storm water runoff is being collected in the mining pit/pond amount of rainwater collected is of the order of
0.845 mcm and is being used for the plantation, dust suppression, cement processing work, etc. These will in
turn decrease the extraction of groundwater by the industry. Besides this, rainwater stored in the mining pits
is providing recharge to ground water by induced infiltration to nearby tubewells as pumping levels of these
tub wells are below the pit bottom.
∗ Secondly, wastewater generated at mines workshop is cleaned with the help of oil- water separator & this
cleaned water is re-circulated & reused.
∗ In the mine lease area at the conceptual stage radius of influence zone due to mine pit dewatering extends
upto about 960 m from the centre of the mine pit. After reviewing the lease area map, it is seen that there is
no spring, public well, river or lake in the area of 1km from the mining pits indicating that there will not be any
influence of pumping water from the mining pits on any other sources
∗ Total recharge from rooftop, roads, cemented and open area of plant area will be 496686 cum. To
accommodate that amount of water 3 dry tubewells and 8 open wells has been constructed.
∗ Total recharge from Nala Originating from Eastern side of Industrial area will be 453974 cum. To accommodate
that amount of water 4 large diameter open well has been constructed on rainwater harvesting pit near plant
gate having 147000 cum water holding capacity has also been constructed.
∗ Total recharge from rooftop, roads, cemented and open area of colony area will be 94852 cum. To
accommodate that amount of water 5 dry tubewells has been connected.
∗ Total recharge from Nala Originating from Eastern & South-Eastern Side of Colony area will be 523320Cum. To
accommodate that amount of water two anicut with 1m height and 4m length has been constructed.
∗ Total recharge to ground water in mine lease area will be 362305Cum. To accommodate that amount of water
two rainwater harvesting pits of 650000 & 40000 Cum capacity with 2 injection wells has been constructed.
∗ Total rainwater available for groundwater recharge for plant, outside area and mines comes out to the tune of
1931140 cum.
Page 322
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
3
CHAPTER 2
SURFACE HYDROGEOLOGICAL & HYDROLOGICAL INVESTIGATION
INTRODUCTION
M/S SHREE CEMENT LTD. is already operating cement plant clinkerization unit. Now management has decided for
expansion of integrated cement plant (Clinker from 11.2 MTPA to 15 MTPA cement from 8.8 to 13.2 MTPA and
waste heat recovery power: 60 MW to 90 MW) near Village Ras, Tehsil Jaitaran district Pali. And also an expansion
of captive limestone mine from 19.6 to 25.3 MTPA at Village Nimbati, Jawangarh Pali, Rajasthan.
For meeting the water demands and conditions of TOR points issued by MOEF for plant and mine, it was decided to
carry out detailed investigation for indicating feasible subsurface resources, which may meet water requirement on
sustainable basis. This study also includes impact of mining activities on water regime. To augment ground water
storage of the area rainwater-harvesting program has also been suggested.
M/S SHREE CEMENT LTD, BEAWAR, RAJASTHAN have retained ASSOCIATE ENGINEERS & CONSULTANTS, Jaipur to
undertake a detailed investigation for assessment and evaluation of subsurface water sources in the area.
This chapter comprises of the main objectives & the investigation methodology.
OBJECTIVES
Hydrological & Hydro geological studies of the core & buffer zone for mine area.
To assess groundwater resources of Core & buffer zone.
To assess impact of mining activity on water regime.
Water conservation measures to augment ground water storage.
Site visit Photographs
OPEN WELLS IN NEAR BY AREAS
GEOLOGY OF THE AREA
Area is mainly composed of moderately thick alluvial cover belonging to Recent to Sub- Recent period of
Quaternary era. Western part of the buffer zone has crystalline and metamorphic rocks of Sirohi, Sendra Ambaji
and Phulad Group of Delhi super group. Erinpura granites have intruded this group as post Delhi intrusive. Details
of the geological succession of the area is as under:
Era Age Super Group Group/
Formation
Rock Type
Quaternary Sub recent to
Recent
Aeolian &
Colluvium
Alluvium Wind blown sand, silty clays
kanker, gravel etc.
-----------------------------------Unconformity ------------------------------------------
Middle to Upper
Proterozoic
Lower Pre-
Cambrian to Upper
Cambrian
Post- Delhi intrusive
& extrusive
Erinpura Granites, Pegmatites
Limestone/ Marble,
Page 323
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
4
Sirohi
Calc-schists, gneisses
Proterozoic Proterozoic Delhi Super Group Sendra
Ambaji
Phulad Ophiolite
suite
Granites, Gneisses
Hornblende schsist
Amphibolites
Page 324
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
5
PHYSIOGRAPHY, DRAINAGE PATTERN & RAINFALL DATA
Nimbeti Limestone deposit forms the part of catchment area of Lilri river, a tributary of Luni river. Lilri river
originates from Ramgarh Narpura hills, north of beawar. After flowing west up to Ras, it takes southern turn,
flowing between two limestone hills, is joined by Sukri River near village Mohari and further downstream meets
Luni River near Nimbol.
Lilri river is an ephemeral stream and flows only in direct response to rainfall in its catchment area. There is well-
developed drainage, which is dendritic in nature. The drainage on the northeasterly trending hills of limestone,
takes westerly and easterly course, ultimately joining Lilri River.
Page 325
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
6
Nimbeti limestone deposit is the most easterly limestone hill, among the four prominent limestone hills, all striking
NE-SW and all hills are being mined and proposed to be mined as source of limestone by other cement plants.
Four minor irrigation projects have been constructed upstream of Ras limestone deposits on Lilri river and its
tributary Sukri. Their details are as under:
S.N. Project Name DSB No. Catchment
area (Km2)
Live storage Mm3
CCA Ha.
1. Karnos Tank 1 26.1 0.3 26
2. Kherabalav 2 3.2 0.1 18
3. Kherawala 2 8.2 0.1 18
4. Babra 1 373.3 3.6 538
DSB :- Differential Sub- Basin
CCA:- Culturable Command Area.
Source:- Irrigation department, 1996
The Mining lease area has a topographical difference of about 100m between lower & uppermost portion of the
area. The min. RL is about 370m & max RL is about 470m. The thickness of alluvial is not much generally less than
1m in mine area. In the plant area topographical difference is about 26m. The min RL is about 374m and max RL is
about 400m. The thickness of alluvial cover varies between 4 to 8m. This area is characterized by wind blown sand
with silt Due to moderate rainfall; resistant hills soil stream density is moderate. Surface has produced dendritic
type of drainage pattern as shown in figure
Page 326
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
7
Figure: Drainage Pattern
Page 327
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
8
Rainfall record of nearest rain gauge at tehsil headquarter Jaitaran is shown in tabular form. It is apparent from
these data that average rainfall of last 15 years is 445 mm. About 90% of it occurs during monsoon months (June to
September) with June and August accounting for 33% and 31% of the annual rainfall respectively. Maximum rain of
over 100mm in a day was recorded on 6th
august, 1976 (100mm), 16th
July 1979 (155mm), 18th
July 1979 (226mm)
and 19th
July 1979 (100mm). The total number of rainy days is 31. in a year with 9.8 days in the month of July.
Aannual rainfall is 557mm for 2014.
ANNUAL RAINFALL DATA
Year Annual Rainfall Highest Rainfall Highest Rainfall Date Rainy Days
1982 362 62 13July 23
1983 810.5 184 21Aug 36
1984 288 56 04Sep 13
1985 191 45 31May 12
1986 151 38 28July 14
1987 139 24 14July 12
1988 351 52 26Aug 24
1989 322 87 27Aug 18
1990 511 90 05Aug 23
1991 370.9 63.4 03Sep 21
1992 569.2 97 19Aug 29
1993 288 50.8 10July 21
1994 752 157.4 02July 31
1995 618 120 26July 22
1996 486.2 82 06Aug 25
1997 645.2 95 08Aug 34
1998 431.2 46 17Oct 24
1999 432.3 150 31July 13
2000 389.4 119 22July 15
2001 563 149 04July 24
2002 233.5 76 23Aug 14
2003 392 48 23July 23
2004 391 46 13Aug 20
2005 304 55 17Sep 20
2006 368 46.5 20July 31
2007 585 177 05July 21
2008 431 85 05Aug 28
2009 229 68 11July 14
2010 571 65 24July 36
2011 640 111 11Aug 31
Page 328
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
9
2012 412 80 12Aug 29
2013 583 125 29 sep 27
2014 557 100 8 Aug 23
GEOMORPHOLOGY
The geomorphology involves the study of landforms of a terrain into units which are classified and subsequently
evaluated for specific type of land utilization. The landforms are the expressions of surface and subsurface
lithological and structural features. The regional perspective of the satellite data makes it very easy to delineate
geomorphic landforms based on tonal and morphological expressions on the IRS, LISS-3 satellite image.
Geomorphological units and associated features identified and mapped in the study area through the visual
interpretation of satellite data taking in to consideration the physiography, geology, structures and drainage
conditions. The study area is classified into different zones covered by structural ridges, structural hills, pediment,
pediplain and alluvium as shown in Figure. The area statistics of identified geomorphic units have been generated
and is given in Table.
Structural Ridges
Linear to curvilinear ridges are found in the study area following NE-SW trend. On the satellite imagery these ridges
are showing the characteristic linear and curvilinear shapes with high relief compared to their surrounding units.
These hills are steep to moderately slopping on both sides. The area under structural ridges is 142.37 ha.
Page 329
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
10
Structural Hills
The structural hills are the isolated eroded uplands found in eastern part of the study area. These structural hills
are formed due to differential erosion of hard and compact lithological formations. The spatial extent of these hills
is very low.
Pediment
Pediment is a gently sloping area with erosional bed rock, situated in between hills and plains consisting of a
veneer of detritus and broad undulating rock floor. The pediment cover in the study area is 156.87 ha. Pediments
are located in central and eastern part of the study area.
Pediplain
Pediplain is relatively flat rock surface formed by the joining of several pediments. Pediplain are usually formed in
arid or semi-arid climates and may have a thin veneer of sediments. It is postulated that the pediplain may be the
last stage of landform evolution, the final result of the processes of erosion. Ultimately, the pediplain comprises an
intricate assembly of pediments which slope down to the local drainage systems. In study area major pediplains
are found in western part and the area under pediplain category is 166.25 ha.
Alluvium
The recent to sub-recent formation in the study area comprises a broad patch of alluvium deposit along the river
course. It is a thick, unconsolidated deposit of sand, gravel clay and silt. The alluvium is found in central part of the
study area and it covers only 2.85 ha area.
GEOMORPHIC UNIT AREA IN HA.
Structural ridge 142.37
Structural hill 0.86
Pediment 156.87
Pediplain 166.25
Alluvium 2.85
River 15.07
Waterbody 3.31
Built-up 5.72
Page 330
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
11
AQUIFER TYPES
Ground water generally occurs in unconfining conditions and is transmitted through the fractures, joints and
foliation plans of granites and gneisses. These rocks are impervious in nature and do not have primary porosity.
These rocks have the secondary porosity due to presence of fracture zone and weathering. The secondary porosity
decreases with depth due to overlying weight of the rocks. Granites and gneisses are prone to weathering, get
weathered to adequate depths and develop primary porosity. Hence maximum hydraulic conductivity is observed
at shallow depth generally less than 100m.
Limestone mostly forms the hills it has been proved to be water bearing and a tube well constructed in the mine
area yield 10,000 lit/hr of water. Limestone of the area is thick bedded, well jointed and therefore is expected to
Page 331
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
12
have adequate fracture porosity and hydraulic conductivity. Most of the rain falling on the top of the limestone
hills is likely to percolate down through the bedding planes and form a ground water basin in the foothill area.
WATER LEVEL AND SEASONAL FLUCTUATION
Water level in the area ranges from 7mts. to 22mts. below ground level in the post monsoon period while during
summer it ranges from 15 to 30m. Seasonal fluctuation in the area is about 8 m. water level monitoring has been
done in the year 2014-15 for mining lease area and plant area. Fluctuation in water levels is mostly due to recharge
of ground water through rainfall and influent seepage from streams and ground water discharge from wells.
YIELD POTENTIAL
There are three operating tube wells in the mining lease area and seven open well/ bore well in the plant area.
Tube wells in the mining area have discharge between 60 to 300 KL/day, while open wells in the plant area have
discharge between 20 to 60 Cum/day.
In the near by areas hand pumps have been constructed by the govt. to an average depth of 60 to 70m. The yield
of such hand pumps is not much and is just sufficient to meet the drinking water requirement. Open wells are
generally 20 to 30m deep and are operated by diesel engines and do not sustain pumping. The average yield of
wells tapping granites ranges between 20 to 120 cum/day. Wells and tube wells tapping alluvium generally yield 20
cum/hrs.
GROUND WATER MOVEMENT
In the investigated area the movement of ground water is governed mainly by secondary fractures as granites and
gneisses are impervious in nature and do not possess primary porosity. The alluvial thickness is very low and
remains unsaturated during major part of the year. The general land slope and drainage in the area is towards East
and is 25 m/km and to north about 5m/km. The ground water also follows the topography and surface water
moves in eastern to northern direction. The hydraulic gradient is not so high and has been observed as a 2.17 per
kilometre. The movement of ground water on the western side of limestone hills is also towards west with low
hydraulic gradient.
Site Visit Photographs
GROUND WATER QUALITY
Quality of ground water is generally potable and electrical conductivity is less than 2000 micromhos per cm. And
total dissolved salts do not exceed 1000 mg/lit. All the constituents remain within allowable limits of drinking water
standards with fluorides remaining less than 1.5 mg/lit and nitrates less than 45 mg/l. water is therefore suitable
for drinking and irrigation purposes.
Page 332
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
13
DETAIL OF HYDRO-GEOLOGICAL STUDIES OF CORE AND BUFFER ZONES OF SHREE CEMENT LTD. (Season April 2015)
S.
No.
Location Type of well Type of Pump
& Depth (Feet)
Pump (HP)
Specification
Depth/ Dia
&Specification of
well
Latitude &
Longitude
Elevatio
n (m)
Water
Level (m)
GW
RL
(m)
1 BHIMGARH OPEN WELL MONO BLOCK 8 HP 90 FT DEPTH,
10*10 DIA
26015’09.6”
074011’42.1”
384 12.53
371.47
2. BUTIWAS BORE WELL SUBMERSIBL
E
5 HP 350 FT DEPTH, 8”
DIA,SINGLE
CASING
26013’18.1”
074009’43.2”
359 5.43
353.57
3. TUNKARA BORE WELL ABSENT NIL 560 FT DEPTH,8”
DIA, SINGLE
CASING
26013’48.2”
074006’52.2”
351 14.11
336.89
4. NIBERA KHURD OPEN WELL MONO BLOCK 20 HP 60 FT DEPTH,
12*12 DIA
26012’16.2”
074006’38.2”
337 11.50
325.5
5. CHAWANDIA
KALA*
BORE WELL SUBMERSIBL
E
3 HP 330 FT DEPTH, 8”
DIA, SINGLE
CASING
26012’16.8”
074008’10.6”
353 20.17
332.83
6. MESSIA OPEN WELL MONO BLOCK 10 HP 60 FT DEPTH,
15*15 DIA
26010’54.9”
074007’21.1”
344 9.57
334.43
7. KHOKHARI OPEN WELL SUBMERSIBL
E
5 HP 40 FT DEPTH,
12*12 DIA
26009’56.3”
074008’01.1”
351 10.18
340.82
8. GIRI OPEN WELL SUBMERSIBL
E
3 HP 60 FT DEPTH,
6*12 DIA
26010’55.4”
074009’42.5”
361 10.84
350.16
9. NAHARPURA OPEN WELL MONOBLOCK 8 HP 60 FT DEPTH,
12*12 DIA
26012’02.3”
074010’58.3”
389 21.60
367.4
10. TEJAJI KA BADIA OPEN WELL MONOBLOCK 5 HP 60 FT DEPTH, 5*8
DIA
26013’05.5”
074011’48.6”
395 11.37
383.63
11. NANANA BORE WELL SUBMERSIBL
E
5 HP 350 FT DEPTH, 8”
DIA, SINGLE
CASING
26010’0.7”
074011’19.7”
390 18.10
371.9
12. RELARA BORE WELL SUBMERSIBL
E
3 HP 350 FT DEPTH, 8”
DIA, SINGLE
CASING
26009’38.5”
074012’24.2”
392 12.78
379.22
Page 333
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
14
13 KANECHA BORE WELL SUBMERSIBL
E
1.5 HP 350 FT DEPTH, 8”
DIA, SINGLE
CASING
26009’41.5”
074013’39.3”
410 21
389
14. SHYAMPURA OPEN WELL MONOBLOCK 5 HP 60 FT DEPTH,
20*20 DIA
26010’38.5”
074012’36.0”
388 12.12
375.88
15. PATAN OPEN WELL SUBMERSIBL
E
5 HP 100 FT DEPTH,
12*12 DIA
26012’17.4”
074013’33.1”
409 31
378
16. NAYAGAON OPEN WELL SUBMERSIBL
E
8 HP 60 FT DEPTH,
18*18 DIA
26013’27.6”
074015’22.5”
400 10.52
389.48
17. RAMGARH BORE WELL SUBMERSIBL
E
3 HP 350 FT DEPTH, 8”
DIA, SINGLE
CASING
26014’36.6”
074015’18.9”
395 16.61
378.39
18. GOPALPURA BORE WELL SUBMERSIBL
E
2 HP 250 FT DEPTH, 4”
DIA, SINGLE
CASING
26014’36”
074013’52.4”
390 8.57
381.43
19. BAGATPURA OPEN WELL SUBMERSIBL
E &
MONOBLOCK
2 HP 60 FT DEPTH,
15*15 DIA
26015’42.4”
074013’22.2”
387 14.35
372.65
20. RAS OPEN WELL SUBMERSIBL
E &
MONOBLOCK
5 HP 60 FT DEPTH,
15*15 DIA
26017’54”
074011’38.8”
364 8.50
355.5
21. KHERA OPEN WELL SUBMERSIBL
E
3 HP 60 FT DEPTH,
15*15 DIA
26016’25.4”
074012’05.4”
374 24.29
349.71
22. DEVGARH OPEN WELL MONOBLOCK 8 HP 40 FT DEPTH,
10*10 DIA
26016’12.4”
074014’53.4”
367 6.31
360.69
23. RATANGARH OPEN WELL SUBMERSIBL
E
3 HP 60 FT DEPTH, 8*8
DIA
26017’17.2”
074016’5.0”
377 16.35
360.65
24. RUPNAGAR
(THORIA)
BORE WELL SUBMERSIBL
E
1 HP 250 FT DEPTH, 6”
DIA, SINGLE
CASING
26016’38.3”
074017’1.5”
384 18.21
365.79
25. RUPAREL OPEN WELL SUBMERSIBL
E
3 HP 120 FT DEPTH,
8*8 DIA
26017’30.4”
074017’3.5”
391 28.83
362.17
26. PALIYAWAS OPEN WELL ABSENT NIL 40 FT DEPTH, 8*8
DIA
26017’33.6”
074014’40.1”
379 6.36
372.64
Page 334
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
15
27. BHILDERA OPEN WELL ABSENT NIL 60 FT DEPTH, 8*8
DIA
26018’52.5”
074015’55.9”
395 13.20
381.8
28. DHOLADATA
(RAJPUTANA)
BORE WELL SUBMERSIBL
E
5 HP 350 FT DEPTH, 8”
DIA, SINGLE
CASING
26019’28.7”
074014’30.9”
395 29.18
365.82
29. PHULSAGAR OPEN WELL MONOBLOCK 8 HP 60 FT DEPTH, 8*8
DIA
26018’38.2”
074017’48.6”
385 8.38
376.62
30. RUPNAGAR OPEN WELL ABSENT NIL 60 FT DEPTH, 5*5
DIA
26019’27.5”
074012’56.4”
379 8.85
370.15
31. CHAINPURA BORE WELL SUBMERSIBL
E
3 HP 350 FT DEPTH, 8”
DIA, SINGLE
CASING
26020’40.2”
074013’05.5”
392 12.95
379.05
32. DAYALPURA BORE WELL SUBMERSIBL
E
7 HP 600 FT DEPTH,
8”,SINGLE
CASING
26021’08.9”
074011’32.1”
394 57.45
336.55
33. BALUPURA BORE WELL SUBMERSIBL
E
3 HP 550 FT DEPTH, 8”
DIA, SINGLE
CASING
26019’53.6”
074008’23.3”
354 50.13
303.87
34. RABARIYAWAS OPEN WELL SUBMERSIBL
E
3 HP 120 FT DEPTH,
8*8 DIA
26019’28.6”
074006’17.7”
328 30.55
297.45
35. PARTAPURA BORE WELL SUBMERSIBL
E
3 HP 200 FT DEPTH,
10” DIA, SINGLE
CASING
26019’34.4”
074005’25.6”
323 26.20
296.8
36. BALARA OPEN WELL ABSENT NIL 60 FT DEPTH,5*5
DIA
26017’21.5”
074004’20”
320 8.50
311.5
37. PYAU BORE WELL SUBMERSIBL
E
5 HP 500 FT DEPTH, 8”
DIA, SINGLE
CASING
26018’43.0”
074009’45.9”
391 36.03
354.97
38. KUNDAL OPEN WELL MONOBLOCK NIL 60 FT DEPTH,
12*12 DIA
26015’17.8”
074009’34.3”
376 10.21
365.79
39. PATAN OPEN WELL MONOBLOCK NIL 30 FT DEPTH, 8*8
DIA
26016’21.9”
074009’17.3”
351 5.19
345.81
40. KHERPURA
(KESARPURA)
OPEN WELL ABSENT NIL 40 FT DEPTH, 8*8
DIA
26017’44.8”
074010’2.4”
361 8.10
352.9
Page 335
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
16
41. AMARPURA BORE WELL SUBMERSIBL
E
3 HP 350 FT DEPTH,
10” DIA , SINGLE
CASING
26021’37.3”
074007’5.9”
326 22.73
303.27
42. RAWATO KI
DHANI
OPEN WELL SUBMERSIBL
E
1 HP 100 FT DEPTH,
10*10 DIA
26022’18.6”
074009’38.8”
347 20.91
326.09
43. SEWARIA OPEN WELL ABSENT NIL 80 FT DEPTH,
10*10 DIA
26020’50.6”
074014’11.6”
386 21.21
364.79
44. SUGALIYA BORE WELL SUBMERSIBL
E
1 HP 600 FT DEPTH, 4”
DIA, SINGLE
CASIING
26008’59.7”
074011’11.8”
398 49.23
348.77
GROUND WATER QUALITY
In the study area ground water samples has been collected from seven different places, quality results are shown in the table below:
Ground Water Analysis
Study Period Post Monsoon Season (2013)
S. No. ParametersProject
SiteMine site
Village
Nimbera
khurd
Village
Patan
Village
Mohrai
Village
Butiwas
Village
Rabariyawas
Specification as per
is:10500
1. pH (at 25 °C) 7.98 7.84 7.13 7.72 7.52 7.80 7.43 6.5-8.5
2. Colour (hazen unit) <5 <5 <5 <5 <5 <5 <5 5 (max,25)
3. Turbidity (NTU) <1 <1 <1 <1 <1 <1 <1 5 (max. 10)
4. Odour Unobjectio
nable
Unobjecti
onable
Unobjecti
o -
nable
Unobjectio
nable
Unobjectio
nable
Unobjection
able
Unobjectionabl
e
Unobjectionable
5. Taste Agreeable Agreeable Agreeable Agreeable Agreeable Agreeable Salty Agreeable
6. Total hardness as CaCO3
(mg/l)
419.00 235.44 149.84 378.56 769.6 172.32 632.29 300 (max. 600)
7. Calcium as Ca+2
(mg/l) 118.38 55.92 34.96 81.70 152.63 39.01 140.06 75 (max. 200)
8. Alkalinity as CaCO3 mg/l 213.96 536.56 361.92 305.06 492.62 356.64 287.08 200(max. 600)
9. Chloride (as Cl), mg/l 325.91 706.25 225.35 139.65 742.30 127.64 890.15 250 (max. 1000)
10. Cyanide as Cn(mg/l) <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 0.05 (no relaxation)
Page 336
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
17
11. Magnesium as Mg+2
(mg/l) 30.04 23.31 15.22 42.46 94.64 18.22 68.73 30 (max. 100)
12. TDS (mg/l) 782.00 1604.00 738.00 586.00 1794.00 606.00 1899.00 500 (max. 2000)
13. Sulphate as SO42-
(mg/l) 42.50 196.25 50.65 38.85 209.45 38.51 163.48 200 ( max 400)
14. Fluoride as F (mg/l) 0.45 0.75 0.51 0.48 0.50 0.72 0.68 1.0 (max 1.5)
15. Nitrates (as NO3) mg/l 2.95 12.37 9.27 14.23 12.68 4.99 3.68 45 (no relaxation)
16. Iron as Fe (mg/l) 0.11 0.30 0.22 0.09 0.16 0.13 0.21 0.3 (max 1.0)
17. Aluminum as Al (mg/l) <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 0.03 (max. 0.2)
18. Boron (mg/l) <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 1 (max. 5)
19. Phenolic compounds (as
C6H5OH) (mg/l)
<0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 0.001 (max. 0.002)
20. Anionic detergents as
MBAS (mg/l)
<0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 0.2 (max.1.0)
21. Hexa Chromium (mg/lit) <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 0.05(no relaxation)
22. Zinc as Zn (mg/l) <0.10 <0.10 <0.10 <0.10 <0.10 <0.10 <0.10 5 (max. 15)
23. Copper as Cu (mg/l) <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 0.05 (max. 1.5)
24. Manganese as Mn (mg/l) <0.10 <0.10 <0.10 <0.10 <0.10 <0.10 <0.10 0.1 (max. 0.3)
25. Cadmium as cd (mg/l) <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 0.01 (no relaxation)
26. Lead as Pb (mg/l) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 0.05 (no relaxation)
27. Arsenic as As (mg/l) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 0.01 (no relaxation)
28. Mercury as Hg (mg/l) <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 0.001 (no
relaxation)
29. Phosphate (mg/l) <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 ---
30. Nickel (mg/l) <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 ---
31. Sodium as Na (mg/l) 89.50 206.00 128.00 46.00 246.60 108.00 399.00 ---
32. Potassium as K (mg/l) 4.00 14.60 12.40 4.89 10.30 5.60 8.80 ---
Page 337
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
18
CHAPTER - 3
GROUND WATER RESOURCES EVALUATION &
IMPACT OF MINING ON WATER REGIME
Ground water resources of an area can be distinguished under two categories:-
1. Dynamic ground water resources
2. Static ground water resources
DYNAMIC GROUND WATER RESOURCES
Dynamic ground water is that amount of water, which is found in the natural zone of fluctuation in an aquifer due
to ground water recharge. Total ground water recharge (RT) of the area can be estimated by assessing the various
components of the following equation: -
RT = Rr+ Rs+ RI+ Sr+ Rc - - - - - - - - - - - - - - - (I)
Where,
Rr = Recharge from Rainfall.
Rs = Recharge from Irrigation due to surface water.
RI = Recharge from Irrigation due to ground water.
SI = Recharge through surface water bodies.
Rc = Recharge to confined aquifers.
GROUND WATER RESOURCES IN THE CORE ZONE
MINING LEASE AREA
The mining lease area covers 7.5 Sq.km. out of which 3.85sq.km is composed of limestone and 3.65 sq.km is
composed of granitic gneisses. Now in this area no irrigation activity is going on. The main source of ground water
recharge is recharge due to rainfall by direct percolation.
RECHARGE DUE TO RAINFALL (Rrm)
(A) BY GROUNDWATER TABLE FLUCTUATION METHOD:
There are three operating tube wells in the mining lease area. One pieziometer is also there and is used for regular
water level monitoring. Water level monitoring was done during pre and post monsoon, 2014 -2015. Under such
situation, increment in ground water storage in the limestone was determined from monitoring this pieziometer.
Increment in ground water storage in gneisses of the core zone was monitored from few old dug wells. Average
seasonal fluctuation in limestone area has been observed as 4.5 m and in Gneisses it is about 5m.
Recharge due to rainfall is computed by specific yield water table fluctuation method as below: -
Calculations should be done considering 3.85 Sq Km Limestone and rest Gneiss
Rr = A × S.F × Sy ------------------------------- (III)
Where,
Rr = Recharge due to rainfall in the investigated area.
A = Rechargeable area = 7.5 Km2
Page 338
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
19
3.85 Sq. Km. in Limestone
3.65 Sq.km in Gneisses
S.F. = Seasonal fluctuation in water level.
4.5 m. as observed in Limestone area
5m as observed in Gneisses area
Sy = Specific yield = 2% for Limestone aquifer
1.5% for Gneisses aquifer
Therefore,
RrmL = 3.85 × 106
x 4.5 × 0.02
= 0.35 mcm/annum
RrmL ≈ 0.35 mcm/annum (For Limestone)
RrmG = 3.65 × 106
x 5 × 0.015
= 0.27 mcm/annum
RrmG ≈ 0.27mcm/annum (For Gneisses)
Rrm = RrmL + RrmG
= 0.35 + 0.27
Rrm = 0.62 mcm/annum
(B) BY RAINFALL INFILTRATION FACTOR METHOD:
In areas where groundwater level monitoring is not adequate in space & time, rainfall infiltration may be adopted.
The ground water estimation committee, Govt. of India (1997) has suggested norms of recharge from rainfall under
various hydro geological conditions. The committee has suggested 15 to 20% as the rainfall infiltration factor for
limestone areas and 10 to 15% for granitic area having sandy soil with moderate rainfall and well-developed
drainage. An infiltration factor of 20% has been adopted for limestone, which are steely dipping, thick bedded,
jointed, highly fractured while 15% for granitic gneisses which appears to be reasonable while looking to the hydro
geological and geomorphological settings. Although, there is no need to use this theoretical approach in the case
that has been monitored. An attempt can be made to find out if it matches with the ground water recharge
calculated by seasonal fluctuation method.
Rr2mL = area x study year rainfall x R.I. factor
= 3.85 x 106
x 0.557 x 0.2
= 0.43 mcm/annum
≈ 0.43 mcm/annum (For limestone)
Rr2mG = Area x study year rainfall x R.I. factor
Page 339
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
20
= 3.65 x 106
x 0.557 x 0.15
= 0.30 mcm/annum
≈ 0.30mcm/annum (For Gneisses)
Rr2 = 0.43 + 0.30 = 0.73 mcm/annum
COMARISON OF RECHARGE
A. Recharge from water table fluctuation method = 0.62 mcm
B. Recharge from rainfall infiltration method = 0.73 mcm
PD = {(A - B)/B} x 100
= {(0.62 - 0.73)/ 0.73} x 100
= {(- 0.146)/ 0.73} x 100
= - 15%
Since the percentage of deviation (-15%) is greater than 20%, the recharge coefficient obtained from water table
fluctuation method.
RECHARGE FROM RAINFALL = 0.62 MCM
TOTAL DYNAMIC RESERVES
Considering all above recharge components, total dynamic reserves in the investigated area will be:
RTm = 0.62 mcm/annum
PLANT AND COLONY AREA
The plant area & colony area covers 3.442 Sq.km. (3.042 sq. km. plant area + 0.4 sq.km. colony area) now in this
area no irrigation activity is going on. The main source of ground water recharge is recharge due to rainfall by direct
percolation and by water used for horticulture & gardening.
RECHARGE DUE TO RAINFALL (Rrp)
(A) BY GROUNDWATER TABLE FLUCTUATION METHOD
Increment in ground water storage in gneisses of the core zone was monitored from few old dug wells. Average
seasonal fluctuation in Gneisses it is about 5m.
Recharge due to rainfall is computed by specific yield water table fluctuation method as below: -
Rr = A × S.F × Sy ------------------------------- (III)
Where,
Rr = Recharge due to rainfall in the investigated area.
A = Rechargeable area = 3.442 Km2
(gneisses)
S.F. = Seasonal fluctuation in water level.
5m as observed in Gneisses area
Sy = Specific yield = 1.5% for Gneisses aquifer
Page 340
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
21
Therefore,
RrP = 3.442 × 106
x 5 × 0.015
= 0.258 mcm/annum
RrP ≈ 0.258 mcm/annum (For Gneisses)
(C) BY RAINFALL INFILTRATION FACTOR METHOD:
In areas where groundwater level monitoring is not adequate in space & time, rainfall infiltration may be adopted.
The ground water estimation committee, Govt. of India (1997) has suggested norms of recharge from rainfall under
various hydro geological conditions. The committee has suggested 10 to 15% for granitic area having sandy soil with
moderate rainfall and well developed drainage. An infiltration factor 15% for granitic gneisses which appears to be
reasonable while looking to the hydro geological and geomorphological settings. Although, there is no need to use
this theoretical approach in the case that has been monitored. An attempt can be made to find out if it matches
with the ground water recharge calculated by seasonal fluctuation method.
Rr2P = area x study year rainfall x R.I. factor
= 3.442 x 106
x 0.557 x 0.15
= 0.286 mcm/annum
≈ 0.286 mcm/annum (For Gneisses)
COMARISON OF RECHARGE
A. Recharge from water table fluctuation method = 0.258 mcm
B. Recharge from rainfall infiltration method = 0.286 mcm
PD = {(A - B)/B} x 100
= {(0.258 - 0.286)/ 0.286} x 100
= {(- 0.028)/ 0.286} x 100
= - 9.8%
Since the percentage of deviation (-9.8%) is greater than -20%, the recharge coefficient obtained from water table
fluctuation will be taken.
RECHARGE FROM RAINFALL = 0.258 MCM
TOTAL DYNAMIC RESERVES
Considering all above recharge components, total dynamic reserves in the plant area will be:
RTP = 0.258 mcm/annum
RTP = 0.258 mcm/annum
Page 341
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
22
TOTAL DYNAMIC RESERVES OF MINING LEASE , COLONY AND PLANT AREA
RT = RTm + RTP
= 0.62 + 0.258
RT = 0.878 MCM/ANNUM
GROUND WATER DRAFT
Ground water draft in the area can be estimated by assessing the various components of the following equation:
DT = Di + Dd + Din + Dw + Det + Do---------------------- (B)
DT = Total ground water draft
Di = Ground water draft for irrigation in the area
Dd = Ground water draft for domestic use in the area
Din = Ground water draft for industrial use in the area
Dw = Ground water draft for irrigation & domestic use around the area in the radius of influence.
Det = Ground water draft by way of evapotranspiration.
Do = Ground water draft as out flow from unconfined aquifer.
MINE & PLANT AREA
From equation no. (B)
DT = Di + Dd + Din + Do + Det
In the investigated area, ground water draft will occur only through existing ground water structure, which are
constructed in the mining lease area and being used for the industrial purpose. Evapo transpiration losses are
negligible as water table is deep. So at present there is no other ground water draft in the investigated area.
Hence ground water draft can be computed by reducing the equation (B) to:
DTm = Din
At present, there are three tube wells tapping limestone in mine area and 6 dug cum well tapping gneisses in the
plant area. All these tube wells and open dug wells are providing 500 cum/day for plant and 100 cum/day for mine.
Industry has got ground water withdrawal permission of 3800 KLD from CGWA. Hence total ground water
withdrawal will be
Din = = 3800 x 365
= 1.38mcm/annum
TOTAL GROUND WATER DRAFT OF MINE, COLONY & PLANT AREA (DT)
DT = 1.38 mcm/annum
GROUND WATER RESOURCES (BUFFER ZONE)
The area of Buffer zone (463.80 Sq.km. 10.942 sq.km = 452.858 sq.km.) lies in Jaitaran Tehsil of Pali district. This
buffer zone has alluvium in western part and crystalline metamorphic like granites, granitic gneisses and mica schist
Page 342
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
23
in eastern part. There is hardly any canal irrigation in the area; almost the entire area of buffer zone is irrigated by
open wells only. Main recharging factor in the area will be recharge due to rainfall and recharge due to return flow
from the applied irrigation.
The ground water fluctuation of water table during pre and post monsoon periods were recorded for the year 2015
from 44 key wells as per the guidelines of the Ministry of Environment & Forest and taking specific yield values of
10% for alluvium and 1.5% for crystalline metamorphic.
RECHARGE DUE TO RAINFALL (RRB)
(A) BY GROUNDWATER TABLE FLUCTUATION METHOD:
Ground water recharge from rainfall for the year 2005, which was below average rainfall for the area, has been
calculated by measuring the rise of water level in key wells of the 454.03 sq.km area of the buffer zone. The water
levels were recorded in the first week of June 2015 and were measured in the third week of September 2014. The
rise of water level indicates the quantity of water percolated to zone of saturation due to recharge from rainfall.
The rise has been varying from 0.6m to 0.75m in alluvium and 2.15 to 5.45m in gneisses, limestone and schist. Such
a high value of rise in water level in crystalline metamorphic is due to low fracture porosity of rocks. The average
rise has been found to be 0.65m in alluvium and 3.95m in metamorphic rocks. Specific yield value of 10% for
alluvium and 1.5% for gneisses will be taken. Out of total area of buffer zone about 49 sq.km falls under alluvium
and 405.03 sq.km in crystalline metamorphic.
Recharge due to rainfall in the buffer zone is computed by specific yield water table fluctuation method as below: -
Rr1 = A × S.F × Sy
For Alluvium
= 49 x 0.65 x 0.1
= 3.185 mcm/annum
For Gneisses
= 403.85 x 3.95 x 0.015
= 23.93 mcm/annum.
Rr1 = 3.185 + 23.928
= 27.113 mcm/annum.
(B) BY RAINFALL INFILTRATION FACTOR METHOD:
The ground water recharge can also roughly estimated by rainfall infiltration method. The ground water estimation
committee, Govt. of India (1997) has suggested norms of recharge from rainfall under various hydro geological
conditions. The committee has suggested 10 to 15% as the rainfall infiltration factor for hard rock areas having
weathered and fractured granitic gneiss and 10 to 15% for alluvial areas having sandy soils. At maximum level
infiltration factor for the area can be taken as 15%.
Rr2 = area x study year rainfall x R.I. factor
= 452.858 x 0.557 x 0.15
Page 343
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
24
= 37.83 mcm/annum
COMARISON OF RECHARGE
A. Recharge from water table fluctuation method = 27.113 mcm
B. Recharge from rainfall infiltration method = 37.83 mcm
PD = {(A - B)/B} x 100
= {(27.113 37.83)/ 37.83} x 100
= {(-10.717)/ 37.83} x 100
= - 28.34%
Since the percentage of deviation (-28.34%) is less than 20%, the recharge coefficient obtained from infiltration
factor method is multiplied by 0.8.
RECHARGE FROM RAINFALL = 37.83 X 0.8 = 30.26 MCM
RECHARGE DUE TO APPLIED IRRIGATION (RIB)
Ground water recharge from the return flow of irrigation water in sandy area is normally taken as 30% of the total
water applied for irrigation as suggested by the committee. There are 395 open dug wells operated for irrigation in
alluvial area and 670 in metamorphic.
Alluvium area
5.69 x 0.3 = 1.70 mcm/annum
Gneisses area
3.06 x 0.3 = 0.918 mcm/annum
RIB = 1.70 + 0.918
= 2.61mcm/annum
TOTAL RECHARGE OF BUFFER ZONE (RB)
RB = RB + RB
= 30.26 + 2.61
RB = 32.87 mcm/annum
GROUND WATER DRAFT OF BUFFER ZONE
From equation no. (B)
DTB = DiB + DdB + DinB + DoB + DetB
In the investigated area, ground water draft will occur due to applied irrigation, due to domestic use, due to
industrial use. Evatranspiration losses are negligible as water table is deep. Hence ground water draft can be
computed by reducing the equation (B) to:
DTB = DiB + DdB + DinB
DRAFT DUE TO APPLIED IRRIGATION (DiB)
Page 344
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
25
The ground water draft in the buffer zone takes place mainly by dug well used for irrigation. There are about 395
dug wells tapping alluvium and 670 wells in gneisses and granites in 30 villages of buffer zone. These wells are being
operated by the cultivators for irrigation and are operated by diesel engines of 8/5 H.P. for 2 to 4 hours a day
depending on the capacity of well to sustain the pumping. Out of 670 wells in granites and gneisses about 610 are
being operated by pumps and rest without pump. As stated earlier discharge of wells in alluvium area is about
120cum/day. Wells of metamorphic have relative less discharge about 40cum/day for pump-operated wells and
about 20 cum/day for without pump operated wells. The annual draft has been calculated after considering that
these structures will operate only for 120 days in a year. The annual ground water withdrawal from these wells is as
under:
395 x 120 x 120 = 5.69 mcm/annum
610 x 40 x 120 = 2.93 mcm/annum
60 x 20 x 120 = 0.144 mcm/annum
DiB = 5.69 + 2.93 + 0.144
= 8.76 mcm/annum
DRAFT DUE TO INDUSTRIAL USE (DinB)
Ambuja cement plant at Rabriwas, which lies in the buffer zone, has also been using the ground water for its
industrial purpose. It has been reported that 10 tube wells with a discharge of 320 cum/day are in operation.
Hence, total draft due to industrial uses is
= 10 x 320
= 3200 cum/day
DinB = 1.16 mcm/annum
DRAFT DUE TO DOMESTIC & LIVESTOCK USE (DdB)
In the buffer area, the population is about 72077 Considering 100 liters (0.1 m3) as domestic consumption in rural
and semi urban area (as per GERC Report 1997), the total water withdrawal for domestic use will be:
DdB = 72077 x 0.1 x 365
= 2.63 mcm/annum
Cattle consumption is assumed to be 10% of projected domestic consumption, which comes out to be 0.263
mcm/aanum
TOTAL DRAFT IN THE BUFFER ZONE
DTB = DiB + DinB + DdB
= 8.76 + 1.16 + 2.89
Page 345
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
26
DTB = 12.81 mcm/annum
SURPLUS DYNAMIC RESERVES OF BUFFER ZONE
Surplus ground water reserves are those reserves, which are available for utilization and are expected to recharge
every year. These reserves calculations are based on the rainfall of 2015. Therefore, surplus reserves (Rw) are
computed as follows: -
RWB = Total Dynamic Reserves - Total ground water draft
RWB = RTB - DTB
RWB = 32.87 12.81
RWB= 20.06 mcm/annum
At the study year rainfall total ground water recharge is 32.87 mcm/annum. Total ground water pumpage is 12.81
mcm, indicating that the area is under safe category and present stage of ground water development is 38% of the
long-term ground water recharge.
GROUND WATER ALLOCATION FOR FUTURE DOMESTIC USE
The net annual ground water availability is to be apportioned between domestic uses, as per the National Water
Policy, Requirement for Domestic water supply is to be accorded priority. The population will be 91480 as per the
projection by 2036 at the growth rate of 11.99%.
Allocation for Domestic water requirement =
= 91480 x 0.1 x 365
= 3.33 mcm/annum
Hence the Future Ground water allocation will be:
= 3.33 2.63
= 0.70 mcm/annum
Page 346
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
27
SUMMARY OF GROUND WATER BALANCE OF SCL RAS
(In MCuM/Year)
A Groundwater recharge in 10 Km radius area
1 Recharge from rainfall 30.26
2 Recharge from other sources
a. Return flow from Surface water applied for
irrigation
Nil
b. Return flow from ground water applied for
irrigation
2.61
Gross recharge 32.87
Net annual ground water availability 32.87
B Groundwater draft
1 Domestic consumption (Projected population by 2015 @
100 lit./day for 365 days)
2.63
2 Cattle consumption (10% of domestic consumption) 0.263
3 Agricultural Requirement
(Based on irrigation area statistics)
8.76
4 Industrial consumption 1.16
Total ground water draft 12.81
C Net annual ground water available
(A-B) 20.06
D Percentage of ground water development 38%
E Category of the area for ground water development Safe
Page 347
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
28
FLOW DIAGRAM OF HYDROLOGIC SYSTEM IN NATURAL CONDITIONS
Surface water out flow
Infiltration
Seepage
Downward Seepage and
Percolation spring flow
Total Draft: 12.81 MCuM/Year
ATMOSPHERE
Land surface
Infiltration.
30.26MCuM/Year
Bodies of surface water
Direct run off
Recharge from other
sources.
2.61MCuM/Year
Natural discharge &
other losses
Nil
Zone of
aeration
Zone of saturation (Net ground water available): 32.87 MCuM/Year
Domestic
consumption 2.63
MCuM/Year
Cattle
consumption
0.263 MCuM/Year
Agriculture
consumption
8.76 MCuM/Year
Industrial
consumption
1.16 MCuM/Year
Surplus ground water available: 20.06 MCuM/Year
Page 348
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
29
AQUIFER PERFORMANCE TEST AND DETERMINATION OF AQUIFER PARAMETERS
AQUIFER PERFORMANCE TEST
Ground water is a replenish able resource, the quantification of which is of great importance for drawing up
plans for utilization and forms an important aspect in judging the potentiality of an area in the line of total
water requirement. A judicious exploitation of ground water resources cannot be planned without the basic
knowledge of ground water hydraulics which is used in evaluating aquifer parameters for predicating total
water resources.
Hydraulic parameters of aquifer system are determined by conducting aquifer performance test at optimum
extraction rate on representative set of exploratory & observation tubewells.
Observation during aquifer performance test includes measurement of water levels and discharge rate. Water
levels were measured with the help of water level indicator and the yield was measured with the help of water
meter installed at the outlet delivery pipe. The effect of pumping was measured in both pumping well at
standard interval for 1050min. data collected during the test were subject to analysis by Jacob s method to
calculate hydraulic parameters of aquifer.
In the present area, aquifer performance test were conducted on one set of exploratory & observation tube
wells). The details of aquifer performance test data are given in the following pages:
Step draw down test:
A step draw down test is one in which the discharge rate is changed in controlled stages. The discharge rate is
maintained at a constant value within the stage. The test is generally carried out in three steps. Drawdown
measurements are taken throughout the test with each step and maximum drawdown of the well is recorded.
The data obtained from the test are utilized in working out long duration pumping rate based on the
characteristics determined as a result of test.
The pumping well was subjected to step drawdown test in 3 stages of 100 min. each with the help of multistage
12.5 Hp submersible pump and control valve.
The data recorded during step drawdown test gave constant rate as 360 m3/day.
AQUIFER PERFORMACE TEST DATA
EXPLORATORY WELL
(i) Depth of tubewell = 550 M.
(ii) Diameter of tubewell = 12 Inches.
(iii) Static water level = 19.08 M.
(iv) Yield = 15,000 lit/hr
PUMPING DATA OF EXPLORATORY TUBEWELLWELL
S.W. L. :- 19.08 m.
Time since pumping
started (min.)
Water level
(m)
Draw Down
(m)
Time since
pumping
Water Level
(m)
Draw Down
(m)
Page 349
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
30
started
1 25.6 23.3 90 29.35 10.27
2 27.6 25.3 100 29.42 10.34
3 28.41 26.11 150 29.58 10.5
4 28.86 26.56 200 29.60 10.52
5 29.8 27.5 250 29.67 10.59
6 29.91 27.61 300 29.72 10.64
7 30.04 27.74 350 29.75 10.67
8 30.22 27.92 400 29.76 10.68
9 30.3 28 450 29.77 10.69
10 30.38 28.08 500 29.79 10.71
15 30.65 28.35 550 29.79 10.71
20 30.88 28.58 600 29.80 10.72
25 31.07 28.77 700 29.81 10.73
30 31.11 28.81 750 29.82 10.74
35 31.18 28.88 800 29.83 10.75
40 31.2 28.9 900 29.84 10.76
45 31.53 29.23 1000 29.85 10.77
50 31.35 29.05 1050 29.85 10.77
55 31.35 29.05 - - -
60 31.42 29.12 - - -
70 31.48 29.18 - - -
80 31.54 29.24 - - -
RECOVERY DATA
TIME SINCE
PUMPING STOPED
(t)
TIME SINCE
PUMPING STARTED
(t )
(t/t ) RESIDUAL
WATER LEVEL
RESIDUAL
DRAW DOWN
1 1051 1051 26.16 7.08
2 1742 871 22.71 3.63
3 1743 581 22.24 3.16
4 1744 436 21.65 2.57
5 1745 349 20.92 1.84
6 1746 291 20.80 1.72
7 1747 249.57 20.65 1.57
8 1748 218.5 20.37 1.29
9 1749 194.33 20.29 1.21
Page 350
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
31
10 1750 175 20.25 1.17
15 1755 117 20.16 1.08
20 1760 88 20.08 1
25 1765 70.6 20.01 0.93
30 1770 59 19.96 0.88
35 1775 50.71 19.88 0.8
40 1780 44.5 19.71 0.63
45 1785 39.66 19.66 0.58
50 1790 35.8 19.60 0.52
55 1795 32.63 19.54 0.46
60 1800 30 19.49 0.41
65 1805 27.76 19.44 0.36
70 1810 25.85 19.39 0.31
80 1820 22.75 19.26 0.18
90 1830 20.33 19.15 0.07
100 1840 18.4 19.12 0.04
150 1890 12.6 19.11 0.03
200 1940 9.7 19.10 0.02
250 1990 7.96 19.10 0.02
300 2040 6.8 19.09 0.01
400 2140 5.35 19.09 0.01
500 2240 4.48 19.09 0.01
600 2340 3.9 19.08 0
Page 351
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
32
HYDRAULIC PARAMETERS:
Transmissivity:
Transmissivity of the aquifer is determined based on Jacob s straight line method, which present good empirical
technique to arrive at most useful hydraulic parameter for the aquifer using all the three segments of time
drawdown curve spread over one log cycle.
First Segment
T = 2.3 Q/ 4 s
Where,
T = Transmissivity of aquifer in m2/day
Q= optimum yield at which test was carried out = 360 m3/day
S= drawdown intercept for one log cycle = 5.6 m (Fig.1)
T = (2.3 x 360)/ ( 4 x3.14 x 5.6)
= 11.7 m2/day
Second Segment
T = 2.3 Q/ 4 s
Where,
T = Transmissivity of aquifer in m2/day
Q= optimum yield at which test was carried out = 360 m3/day
S= Drawdown intercept for one log cycle = 1.6 m (Fig.1)
T = (2.3 x 360)/ ( 4 x3.14 x 1.6)
Page 352
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
33
= 41.20 m2/day
Third Segment
T = 2.3 Q/ 4 s
Where,
T = Transmissivity of aquifer in m2/day
Q= optimum yield at which test was carried out = 360 m3/day
S= residual drawdown intercept for one log cycle = 0.3 m (Fig.1)
T = (2.3 x 360)/ (4 x3.14 x 0.3)
= 219.74 m2/day
Average Transmissivity
= (11.7+41.20+219.74)/3
= 272.64/3 = 90.88 m2/day
Hydraulic Conductivity:
This parameter is defined as rate of flow of water through one meter thickness of aquifer from unit cross
sectional area. It is determined by the formula:
K = T/b
Where,
T= Transmissivity of the aquifer = 90.88 m2/day
b= saturated thickness of the tested well = 128.62 m ( depth of well water level)
K = 90.88/128.62
= 0.71 m/day
K = 0.71 m/day
Radius of Influence:-
In the investigated area one tubewell is located at a distance of 120m from the pumping well. During the
pumping test it has been observed that there is no drawdown in that well during the pumping. Hence in
absence of any other observation well in near vicinity the radius of influence can be taken as half of the distance
between the wells i.e. 100m at a pumping rate of 360 m3/day.
RADIUS OF INFLUENCE = 100M
Hydraulic Gradient:
As per the water level contour map of the buffer zone hydraulic gradient works out to be 2.8 m/km.
Page 353
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
34
Effect of Mining on groundwater regime:
Observation well of the 120m depth in the area was observed for change in water level and quantity during 17
hrs of pumping. It was observed that continuous withdrawal of water @ 360m3/day caused effect of 10.17m in
the pumping well Further, analysis of data also reveals that there is no effect on natural recharge rate beyond
radius of influence which works out to be 60m with continuous pumping of 17 hrs. However, continuous
pumping for several days may spread the cone of depression beyond 60m. It is also observed that as area falls
under hard rock and groundwater occurs in fractures of the rocks, there is a decrease in tube well discharge in
peak summer season. With the decreased discharge, radius of influence also decreases.
The mining activity, as per the conceptual plan is proposed to be confined to an area of 450 hectares of the
limestone area and will be up to elevation of 252m above m.s.l. the mining pit will be about 123m below the
general land surface and will be ultimately left as water reservoir. This situation will occur atleast after 36 years.
The mining activity, initially being confined to the top of a hill, which lies above the zone of saturation, is not
going to affect the ground water. However, when the main mining pit achieves the elevation of 350 msl, it will
start receiving ground water inflow during the post monsoon period.
IMPACT OF MINING ON GROUND WATER REGIME
The ground water assessment studies carried out for the mining lease area indicates that there is surplus
exploitable ground water potential of 0.658 mcm it is because of adequate ground water recharge from rainfall
Page 354
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
35
and negligible groundwater extraction in the mining lease area measuring 7.5 sq.km. it is therefore clear that
core area is not overexploited as compared to the buffer zone.
It is therefore observed that mining of limestone has not affected the ground water recharge. On the contrary,
there is surplus ground water potential in the lease area as compared to its adjoining buffer zone.
During The hydrogeological investigation it has also been observed that occurrence of ground water is generally
controlled by secondary porosity developed in the metamorphic and due to this metamorphic generally have
very low hydraulic conductivity this also decreases with depth.
Extents of Present Workings as on 31 march 2015
Stages Bench Floor
Level
Net Area
(in Hect) after backfilling
Perimeter
(in Mtr)
Present Pit Pit-1 372 130 (No Back Filling) 8270
Pit-2 408 81(No Back Filling) 7350
YEAR-WISE DEVELOPMENT
No overburden is found in the area as limestone is directly exposed. They are mined separately and dumped in
dump yard. The ramps and haul roads are maintained upto working faces in each block. The year wise
development for the first five years is being given in the table.
Year Pit no. Bottom
Bench
RL
Avera
ge
Top
RL
Average
surface RL
(M)
Water Table
RL (Pre
monsoon)
Water Table
RL (Post
monsoon)
Pit size
(Hect.)
After
backfilled
Direct rainfall
accumulation
(A x rainfall x0.9
(m3)
At the
end of Ist
year
(2015-16)
i.e. as on
31 march
2016
Pit No.1 360 444 375 345 350 150 ha(no
back filling)
600750
Pit No. 2 408 444 375 345 350 90 ha(no
back filling)
360450
At the
end of IInd
year
(2016-17)
i.e. as on
31 march
2017
Pit No.1 360 444 375 345 350 165 ha(no
back filling)
660825
Pit No. 2 396 444 375 345 350 95 ha(no
back filling)
380475
Page 355
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
36
At the
end of
IIIrd
year
(2017-18)
i.e. as on
31 march
2018
Pit No.1 360 444 375 345 350 170 ha(no
back filling)
680850
Pit No. 2 396 444 375 345 350 100 ha(no
back filling)
400500
At the
end of
IVth
year
(2018-19)
i.e. as on
31 march
2019
Pit No.1 360 444 375 345 350 175 ha(no
back filling)
700875
Pit No. 2 396 444 375 345 350 105 ha(no
back filling)
420525
At the
end of Vth
year
(2019-20)
i.e. as on
31 march
2020
Pit No.1 360 444 375 345 350 178 ha(no
back filling)
712890
Pit No. 2 396 444 375 345 350 110 ha(no
back filling)
440550
Water table will not intersect in first five year
At the end of present mining scheme total excavated area will be 290 hact. Considering 445 as average rainfall
rainwater accumulated in the excavated area works out to be 2.90 x 0.445 x 0.9 = 1.16 mcm.
Details of Excavated / Open Area of Mining Pit
Year of Mining Pit No. Depth of
pit* (in bgl /
mRL)
Max. length
of pit** (in
m)
Max. width
of pit***
(in m)
Net area excavated/ available
during the year - after back filling
(in hectares)
5TH
year (End of 2019-20) Pit No.1 360 2140 1250 178 ha (No Back filling)
Pit No. 2 396 2550 600 110 ha (No Back filling)
15th year Single Pit 300 5000 1500 295 ha Total Excavated (No Back
Filling)
25th year Single Pit 252 5100 1600 439 ha Total Excavated (250 ha
Back Filled area)
Conceptual stage (27th
year) Single Pit 252 5230 1600 450ha Total excavated Area
(Partly Back filled 260 ha & water
Page 356
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
37
Reservoir 190 ha)
ANTICIPATED LIFE OF MINE
Considering present production capacity of 25.3 MTPA, the life of mine will be approximately 27 years.
CONCEPTUAL MINING PLAN
Ultimate Size of the Pits
The ultimate size of the pits is given below and shown on conceptual plan.
Area Depth Water level
450ha 252 350 MRL
(Partly Back filled 260 ha & water Reservoir 190 ha)
PRESENT STATUS
General Ground Level Water Level
375 MRL Post Monsoon = 350 MRL or 25m bgl
Pre Monsoon = 345 MRL or 30m bgl
Broken up area (Hact) Depth of
mining (MRL)
Rainwater Accumulation
(mcm)
Groundwater seepage (mcm)
Lean Period Monsoon
211 372 pit1
408 Pit2
0.845 Nil Nil
END OF PRESENT MINING PLAN YEAR (2017)
General Ground Level Water Level
375 MRL Post Monsoon = 350 MRL or 25m bgl
Pre Monsoon = 345 MRL or 30m bgl
Broken up area (Hact) Depth of
mining (MRL)
Rainwater Accumulation
(mcm)
Groundwater seepage (mcm)
Lean Period Monsoon
290 372 1.16 Nil Nil
Water table will intersect after 15 years when mining will reach a depth of 350 MRL.
CONCEPTUAL STAGE
At the conceptual stage mining will attain a depth of 252 MRL ( 123m) from ground level and water level in the
area is 25 to 30 m. hence have possibility of getting ground water seepage. Ground water inflow in the mine is
calculated using Darcy Low:
Q = KIA
Where
Page 357
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
38
Q = inflow of water in Cum/day
K= Hydraulic Conductivity = 0.71 m/day
I= Hydraulic gradient = 2.8/1000
A= Cross sectional area
Depth of Mining = 123m (252 MRL)
Water levels
Post Monsoon period = 25m (350 MRL)
Pre Monsoon Period = 30m (345MRL)
POST MONSOON PERIOD
A= Cross sectional area = 5230 x 101.
Q = 0.71 x 2.8/1000 x 5230 x 98
= 1018 Cum/day --------- (a)
Considering 270 days as the period for Post monsoon season, ground water seepage works out to be
= 1018 x 270 = 274860 Cum/annum (Considering 270days)
PRE MONSOON PERIOD
A= Cross sectional area = 5230 x 93.
Q = 0.71 x 2.8/1000 x 5230 x 93
= 966 Cum/day --------- (b)
Considering 90 days as the period for pre monsoon season, ground water seepage works out to be
= 966 x 90 = 86940 Cum/annum (Considering 90days)
In the Pre-monsoon period expected inflow will be estimated as 966 Cum/day. While during the Post Monsoon
period it will be estimated as 1050 Cum/day.
General Ground Level Water Level
375 MRL Post Monsoon = 350 MRL or 25m bgl
Pre Monsoon = 345 MRL or 30m bgl
Broken up area (Hact) Depth of
mining (MRL)
Rainwater Accumulation
(mcm)
Groundwater seepage (mcm)
Pre-monsoon Post-Monsoon
450
(Partly Back filled 260
ha & water Reservoir
190 ha)
252 0.760 0.087 0.274
EXPECTED IMPACT ON HYDROGEOLOGICAL REGIME OF AREA
Page 358
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
39
Present status
Recharge Draft Impact
Natural recharge ( Calculated using
seasonal fluctuation, rainfall infiltration
factor)
= 0.79 mcm/annum
2. Artificial recharge due to rainwater
harvesting in and around area by SCL =
1.59 mcm
Total = 0.79 + 1.59
= 2.38 mcm
Industry use, = 1.38
mcm/annum
No water table intersection
Surplus reserve
= 1.0 mcm/annum
Stage of development
= 57%
No negative impact as SCL is doing
rainwater harvesting more than
groundwater extraction. It is also vatted
by CGWA.
First Five Year
Natural recharge ( Calculated using
seasonal fluctuation, rainfall infiltration
factor)
= 0.79 mcm/annum
2. Artificial recharge due to rainwater
harvesting in and around area by SCL =
1.59 mcm
Total = 0.79 + 1.59
= 2.38 mcm
Industry use, = 1.38
mcm/annum
No water table intersection
Surplus reserve
= 1.0 mcm/annum
Stage of development
= 57%
No negative impact as SCL is doing
rainwater harvesting more than
groundwater extraction. It is also
vatted by CGWA.
Conceptual stage
Natural recharge ( Calculated using
seasonal fluctuation, rainfall infiltration
factor)
= 0.79mcm/annum
2. Artificial recharge due to rainwater
harvesting in and around area by SCL =
1.59 mcm
3. Natural recharge due to accumulated
rainwater= 0.076 mcm.
Total = 0.79 + 1.59 + 0.076
= 2.456 mcm
Mine seepage due to water table
intersection
Pre monsoon = 0.087
Post Monsoon
= 0.274 mcm
Total Draft
= 0.361mcm
Surplus reserves
2.456 0.37
= 2.086 mcm
Stage of development = 15%
No negative impact area will remain
in safe zone
RADIUS OF INFLUENCE AROUND THE MINING PIT
The open cast mining generally is carried out below local water table conditions. Under these circumstances
groundwater accumulates in the mine pit. The quantity of the groundwater that can accumulate in the pit
bottom is governed by the aquifer properties and their lateral extent beside proximity of surface water sources
like perennial rives, ponds, reservoirs, tanks, springs etc. in order to win the ore it is therefore essential to
provide dry bottom conditions for the mine related operations. This task is generally achieved by installing
pumps. While dewatering the mine pit the groundwater levels around the pit would gradually decline thereby
creating a cone of depression. The lateral extent of this cone of depression depends on pumping rate, pumping
duration, boundary conditions and aquifer parameters.
Page 359
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
40
The mining operations are invariably are governed by certain environmental laws in order to minimize their
impacts on the natural resources in the vicinity. Groundwater regime around the mining lease is one of such
natural resources, which come under the purview of the environmental law implementation. Under this law the
mining operation should not cause significant decline in the groundwater levels. In order to find lateral extent of
such groundwater lowering around the active open cast mining involving dewatering several scientific methods
can be adopted. Few of the relevant and important methods are describe in the following paragraphs:
METHODOLOGY
(1) Well equation method:
This method is essentially meant for estimating the pumping rate from proposed mine excavation and is based
on standard well- hydraulic theory. However, expression for estimating the influence radius has been derived in
the present case by readjusting the equation derived for estimating the pumping rate. This method is somewhat
complicated by the transient development of the cone of depression caused by pumping and, in practice, the
approach is to compute a range of pumping rates that will sustain the required water table drawdown under
steady state conditions. To do this, the radius of an equivalent well must be used to replace the multiple well
point. The equivalent well is assumed to be a circular area representing the plan-view size of the excavated
mine pit and generating a cone of pumping depression in the groundwater table similar to that produce by well
point system.
In the case of circular mine pit excavation, the radius of the equivalent well (r) is the radius of the
excavated mine pit. in a rectangular or polygonal mine pit excavation, the equivalent radius (rc) is
derived from the equation:
rc = ab/ ------------- (i)
Or
rc = A/ -----------------(ii)
Where
Rc= equivalent radius of an equivalent well (i.e. rc = r) and r is small in comparison to the radius of the cone of
depression (R); a and b are the length and breadth of the excavated rectangular shape mine pit. In case of
polygonal excavation the area (A) of the polygon can be estimated and substituted in equation to estimate the
equivalent radius.
= the ratio of the circumference of a circle to its diameter.
The pumping rate Q required to dewater the mine pit excavation may be estimated by using the gravity flow
equation:
Q = K(h12- h2
2)/In (R/rc) --------------------- (iii)
Where,
Q= pumping rate from mine pit
h1 = saturated thickness of the aquifer before pumping.
h2 = elevation above the base of the aquifer for the steady state condition.
R = Radius of fully developed cone of depression.
Page 360
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
41
r= radius of equivalent well
in case of active mine operations it become essential to estimate the zone of influence R around the mine pit
due to a known pumping rate Q derived from the groundwater. This can be achieved by rewriting the equation
as :
In (R/rc) = K(h12- h2
2)/Q ---------------- (iv)
R = rc Exp{[ K(h12- h2
2)/Q]} ----------------- (v)
Hence, the influence radius due to mine pit dewatering can be estimated using the expression (v). the factor
(h12- h2
2) can be taken as the average depth of mine pit bottom below the local groundwater table. Having
known the pumping rate Q from the mine pit if the entire pit water is derived from the groundwater or that
component of the flow derived from groundwater contribution, hydraulic conductivity of the saturated zone it
is possible to estimate the influence zone.
(2) Hudak s method of capture zone delineation:
The capture zone defines the part if an aquifer that will contribute water to a pumping well over a period of
time ( Hudak,1994). In the present case the well has been replaced by a mine pit from which groundwater has
been pumped as part of the dewatering process. The volume of aquifer, Vc that contributes water to a mine pit
over a period of time t is :
Vc = Q(t)/ne ------------------------- (vi)
Where Q is the discharge rate from the mine pit, and ne is the effective porosity of the aquifer.
The area Ac around the excavated mine pit that contributes water to the mine pit is given by;
Ac = Vc/b ------------------------(vii)
Where b is the saturated thickness of aquifer.
Combining equations (vi) & (vii) yields
Ac = Q(t)/ {ne b} ------------------- (viii)
Thus, the area of the capture zone is inversely proportional to the effective porosity, i.e. Ac 1/ ne
For a homogeneous and isotropic aquifer with an axisymmetric radial flow the radius of the capture zone
around the mine pit can be estimated as;
R = [ A/ ] + rc ------------------ (ix)
Where Ac is the equivalent radius of the excavated portion of the non circular mine pit and rc is equal to the
radius of the excavated mine pit if the pit is circular in shape.
Hence by knowing the pumping rate from the mine pit and effective porosity, equivalent mine pit radius and
saturated thickness the radius of influence zone around the mine pit can be estimated using above relations.
The effective porosity term in the above equation can be replaced by specific yield as the specific yield of an
aquifer represents the void space that will yield water to mine pit is effective in furnishing water supplies, it is
also know as effective porosity (Johnson, 1967). Hence, specific yield is equal to effective porosity (Karanth,
1994).
Research has also suggested that in sediments, the pores are interconnected and the effective pore fraction for
water molecules should be 1.0, and hence effective porosity is equal to porosity because (Fetter.1990)
Page 361
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
42
ne = n (porosity) x 1.0 (effective pore fraction)
it is easy to estimate the insitu specific yield of an aquifer through pumping tests rather than effective porosity
of the aquifer. Therefore using specific yield in the above expressions is justified.
COMPUTATION
1. well equation method
The expression required for estimating the radius of influence zone in this method is written as ;
R = rc Exp{[ K(h12- h2
2)/Q]}
The input parameters for this method from the lease area are;
K the hydraulic conductivity of the aquifer = 0.71 m/day.
h12- h2
2the saturated thickness of aquifer = 93m.
Q the mine pit pumping rate = 1018 Cum/day
rc the radius of equivalent well = 800m
By substituting all the values in the above expression the radius of influence zone will be 977m from centre
of mine pit.
2. Hudak s method of capture zone delineation
The expressions required for estimating the radius of influence zone in this method are written as;
(1) Vc = Q(t)/ne
(2) Ac = Vc/b
(3) R = [ A/ ] + rc
the input parameters for this method from the lease area ;
Q groundwater component of the mine pit discharge rate = 1018Cum/day.
t the time of pumping = 365days
ne the effective porosity at the lease area = 0.02
b the saturated thickness = 93m.
the radius/ equivalent radius of mine pit = 800m
by substituting the above values in the expression (1), (2) & (3) we get the values of;
(1) Vc = Q(t)/ne
Vc = 18578500 Cum.
(2) Ac = Vc/b
Ac = 199768 Sq.m.
(3) R = [ Ac / ] + rc
R = 942 m
Therefore the radius of influence zone estimated by this method is 921m.
Average of two method
1. well equation method = 977m.
2. Hudak s method = 942m
Average = 959 960m
Page 362
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
43
After reviewing the lease area map, it is seen that there is no spring, public well, river or lake in the area of 1KM
from the mining pits indicating that there will not be any influence of pumping water from the mining pits on
any other sources.
IMPACT OF MINING ON WATER QUALITY
With the initiation of mining activity on the top of limestone hill, no impact on the quality of surface and
ground water is expected. Accordingly, the quality of water will also be not affected due to mining activity.
Limestone, hard and crystalline in nature does not contribute any constituents to surface and ground water
that may cause increase in salinity. Generally, in an arid area, any major quantitative changes in groundwater
withdrawal also produce qualitative changes in the ground water. Here as the area is not over exploited, there
is no possibility of any changes in the water quality.
*****
Page 363
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
44
CHAPTER-4
ARTIFICIAL GROUND WATER RECHARGE
NEED FOR ARTIFICAL GROUND RECHARGE
Based on the assessment of long term ground water recharge of mining lease and plant area, which amounts to
0.72 mcm/annum, the total requirement of 3800 KLD will go upto 1.04 mcm/annum. This requirement can be
meet out from both mine and plant area but by doing this status of ground water become 114% resulting to
overexploitation. As over exploitation of ground water resources can not be allowed, it is necessary that ground
water storage of the area must be augmented by rainwater harvesting so that the ultimate ground water
development become less than 70% of the ground water recharge.
NATURE OF PROBLEM
Rainfall is only source of water in the area; rainfall & evapotranspiration are two major factors controlling the
quantum of rainwater available for recharge. The investigated area receives rainfall for just 20 days a year. Thus
not only the total rainfall but also its availability is confined to few days during which entire water resources
planning has to be done.
The other important factors controlling the natural recharge to ground water are rainfall intensity,
hydrogeology & depth of water level. It is observed that majority of rainfall occurs in 3-5 major storms lasting
only a few hours. Natural recharge to ground water is further restricted due to impervious hard strata. Some of
water, which infiltrates during rainy period, is entrapped in the soil and it never reaches the water level. This
water is ultimately lost due to potential evapo- transpiration. The rates of potential evapo - tranpiration (PET) is
very high in the area. On an average, annual PET is higher than the rainfall in the area. Thus any artificial
recharge by indirect techniques should be such that most of the water stored on surface is put to ground water
within the shortest possible time to avoid losses.
As indicated earlier, hydro geologically the mining lease area is composed of crystalline, thick bedded, steeply
dipping limestone and is most favourably constituted for artificial ground water recharge through check dams,
bunds etc. This will help in augmenting the groundwater storage around the tube wells and open wells so that
they can sustain in summer also.
Design of Roof Top Rainwater and Surface Runoff Harvesting System
Rainfall intensity calculation
This is the most important parameter of rainfall, which is required for design of various structures. In
engineering design, it is uneconomical to design structures to cope with extreme events. A designer takes a
calculated risk and designs a structure that will accommodate the largest rainstorm that can be expected during
a particular interval.
The central soil & water conservation research & training institute, DehraDun have developed empirical
relationship to calculate rainfall intensity for different agro climatic regions. Which is described as under: -
I = KTa/ (t + b)
n
Page 364
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
45
Where,
I = Rainfall intensity in mm/hr.
T = Recurrence interval in years = 10 years
t= Rainfall duration in hours
K= Constant = 6.219
a = Constant = 0.1026
b = Constant = 0.5
n = Constant = 1.1172
The parameter, t (duration, hr.) the time of concentration of an area, can be computed using the following
equations:
t= 0.01947 Kc0.77
Where,
Kc = √(L3/H)
t= time of concentration
L = Maximum length of travel in meters = 540m.
H = Difference in elevation between most remote point and outlet in meters
Highest level of surface runoff area = 390 m.
Lowest level of surface runoff area = 384 m.
Difference of level (H) = 6 m.
Length of flow = 540 m.
Time of concentration (t) = 0.01947 [(L3/H)
1/2]
0.77
= 0.01947 [(5403/6)
1/2]
0.77
= 13.98min = 0.2331 Hours
Rainfall intensity for the investigated area
I = KTa/ (t + b)
n
= 6.219 (10)0.1026
/(0.2331 +0.5)1.1172
= 11.14 cm/hr
= 111.4 mm/hr.
Rooftop rainwater runoff:-
The industrial roofs are of RCC finished with cement sand mortar. Most of the water can be collected with roof
drains hence 85% rainwater can be available. About 15% of water is lost in evaporation etc. The water is
collected through rainwater drains from rooftop. The roof should be finished to avoid percolation and should
be cleaned every year before rains. The roof top rainwater & surface runoff rainwater shall be collected
through existing rainwater drains
Surface Runoff of Rainwater
Page 365
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
46
The subsurface reservoirs are technically feasible alternative for storing surplus monsoon runoff. Wide
spectrums of techniques are in vogue to recharge ground water reservoir. The artificial recharge techniques
vary widely depending upon hydro geological studies of the area. The detailed hydro geological studies were
carried out and it was found that water table of area is 7 to 15m in post monsoon period.
The maximum rate at which water can enter the soil at particular point depends upon infiltration capacity. The
infiltration capacity depends upon soil type, moisture content, organic matter, vegetative cover, season, air
entrapment, etc. The infiltration and percolation capacity are closely related. The infiltration takes place due to
gravity but capillary force divert gravity water.
The infiltration capacity of land formation is not suitable for surface percolation system hence for recharge of
ground water reservoir through injection well system is proposed. This system will improve both quality &
quantity of water.
Runoff coefficient for soil of Ras area can be taken as 20%. Runoff coefficient for limestone hills, that has no soil
cover and very scanty vegetation can be taken as 50%. Similarly for cemented area it has been taken as 70% and
for lawn and other green area it can be taken as 35%.
Average runoff coefficient taken for the area is as under:
1. Average runoff coefficient for rooftop = 85%
2. Average runoff coefficient for cemented area = 70%
3. Average runoff coefficient for Lawn = 35%
4. Average runoff coefficient for open land (alluvium) = 20%
5. Average runoff coefficient for limestone hills = 50%
Following methods shall carry out the rainwater harvesting
1. Roof top rainwater harvesting by recharge tube wells.
2. Surface rainwater runoff available from roads, cemented area and open land inside the industry shall
be used for recharging through existing dugcum bore wells/ dry tube wells.
3. Surface runoff of rainwater available from the hills of mine area shall be recharged to underground
water bearing aquifer by constricting recharge pond, injection wells.
4. Surface runoff available from the nala entering in the colony through existing openwells/injection wells
with Check bund in nala bed.
1. Rainfall Recharge in the Proposed Industrial Unit:-
The total area under plant & colony area is 3.442 Sq.km (3.042 Sq.km Plant + 0.4 Sq.km Colony) and
mine area is 7.5 Sq.km.
PLANT AREA
A. Roof top rainwater Runoff:
The area has many buildings with V-shaped and flat roof. To collect rainwater, gutters are attached at the end
of roof and these gutters are connected to rainwater drains. The total Rooftop rainwater shall be diverted to
the recharge tube wells through drains and injected into aquifer after passing through the filter pit.
Page 366
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
47
Total Roof top area = 33149 Sq.m.
Average Yearly Rainfall = 445 mm
Average Rooftop Rainwater Available:
= A x Rf x AvRc
Where,
A = Area of Roof.
Rf = Rainfall = 445m.m. (Average)
AvRc = Average runoff coefficient = 85%
= 33149 x 0.445 x 0.85 = 12539 Cum. -------------- (i)
B. Blacked Topped roads & cemented area:
The Plant area has approach roads from entry gate to different buildings. These roads will be 8m, 6m wide.
The project area also has parking area & other cemented portion. Slop of these cemented area and roads
are maintained in such a way that the available runoff should move towards the proposed open drains and
this water shall be taken to the recharge tube wells. Total roads and cemented area has been calculated as
under.
Area under road and cemented portion
= 966851 Sq.m.
Taking 70% as runoff coefficient for both roads and cemented area, the availability of water has been estimated
as under:
966851 x 0.445 x 0.7 = 301174 Cum. -------------- (ii)
C. Open land:-
Total open area considered for rainwater harvesting is 2023450 Sq.m. To collect maximum amount of
rainwater it has been proposed that the slop of the open land should be kept towards the drains and water so
collected should be injected in the dry openwell/ borewells.
Area of open land = 2023450 Sq.m.
Taking 20% as runoff coefficient for open land, the availability of water has been estimated as under:
2023450 x 0.445 x 0.20 = 180087 Cum. -------------- (iii)
Similarly, there is about 18550 sq.m. of area is under lawn. Taking 35% as runoff coefficient for this green area,
the availability of water has been estimated as under
18550 x 0.445 x 0.35 = 2889 Cum. ------------ (iv)
To accommodate rainwater runoff available in the plant area total 11 no of rainwater harvesting structures ( 8
open wells and 3 BW) and one rainwater harvesting pit of 147000 Cum capacity near plant gate has been
constructed.
COLONY AREA
A. Roof top rainwater Runoff:
Page 367
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
48
The area has many buildings with V-shaped and flat roof. To collect rainwater, gutters are attached at the end
of roof and these gutters are connected to rainwater drains. The total Rooftop rainwater shall be diverted to
the recharge tube wells through drains and injected into aquifer after passing through the filter pit.
Total Roof top area = 51000 Sq.m.
Average Yearly Rainfall = 445 mm
Average Rooftop Rainwater Available:
= A x Rf x AvRc
Where,
A = Area of Roof.
Rf = Rainfall = 445m.m. (Average)
AvRc = Average runoff coefficient = 85%
= 51000 x 0.445 x 0.85 = 19291 Cum. -------------- (v)
B. Blacked Topped roads & cemented area:
The colony area has approach roads from entry gate to different buildings. These roads will be 8m, 6m
wide. The project area also has parking area & other cemented portion. Slop of these cemented area and
roads are maintained in such a way that the available runoff should move towards the proposed open
drains and this water shall be taken to the recharge tube wells. Total roads and cemented area has been
calculated as under.
Area under road and cemented portion
= 200000 Sq.m.
Taking 70% as runoff coefficient for both roads and cemented area, the availability of water has been estimated
as under:
200000 x 0.445 x 0.7 = 62300 Cum. -------------- (vi)
C. Open land:-
Total open area considered for rainwater harvesting is 149000 Sq.m. To collect maximum amount of rainwater
it has been proposed that the slop of the open land should be kept towards the drains and water so collected
should be injected in the dry openwell/ borewells.
Area of open land = 149000 Sq.m.
Taking 20% as runoff coefficient for open land, the availability of water has been estimated as under:
149000 x 0.445 x 0.20 = 13261 Cum. -------------- (vii)
To accommodate rainwater runoff available in the colony area 5 injection wells with desilting and filter pit and
one harvesting pit of 40000 Cum capacity has been constructed.
D. Nala Originating from Eastern side of Industrial Unit:-
From the eastern side of industrial unit, three seasonal nala originates. These nalas enters in the newly
acquired area from eastern & southeastern side (Refer Plat-1). This land is the part of pond located outside the
Khera gate of industry. Similarly rainwater from 5400N to 3000N of Mining lease area is also flows towards the
same pond total catchment area works out to be 4857938 Sq.m . Hence a huge quantity of rainwater
Page 368
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
49
accumulates near the boundary, which is located in the pond. This accumulated rainwater is being used for
recharging by diverting it through large diameter pipes to large diameter open wells constructed in the
industrial boundary. Taking 30% as the runoff coefficient average runoff available has been calculated as
under:
Catchment area = 2480000 + 2377938 = 4857938 Sq.m.
Runoff coefficient = 30%
Available runoff = 4857938 x 0.445 x 0.3
= 648534Cum.
Expected recharge = 648534 x 0.7
= 453974 cum/annum ----------- (v)
Boundary wall of the industry is situated in the pond hence act as a retaining wall. Rainwater thus accumulated
has been diverting to large diameter open wells ( 4 No.) through pipes. To control inflow of rainwater in the
wells these pipes are provided with the control valves.
E. Nalas Originating From Eastern & South-Eastern Side of Colony area
Two nalas originating from nearby areas flow in different directions in the Colony area. Total catchment area of
these nalas has been calculated. It works out to be 4200000 Sq.m. Taking 35% as the runoff coefficient for
gently sloping barren land average runoff available has been calculated as under:
Catchment area = 4200000 Sq.m.
Runoff coefficient = 35%
= 4200000 x 0.445 x 0.35
Available Runoff = 654150 Cum/ annum
Expected recharge = 654150 x 0.8
= 523320 cum/annum --------------- (vi)
As this runoff water is available in a seasonal nala. to get maximum amount of water for recharge two anicut
with 1m height and 4m length at different location has been Constructed.
Total Recharge available in Plant area
= (i) + (ii) + (iii) + (iv) + (v) + (vi)
= 12539 + 301174 + 180087 + 2889 + 19291+ 62300 + 13261 + 453974 + 523320
= 1568835 Cum/annum.------------- (A)
2. Mine Area
Mining lease area has a topographic difference of about 100m between lower and upper most portion. The min.
RL is 370m and max. RL is 470m. as the formations are steeply deeping, most of the rainwater flows through the
slopes. Most of the rainwater thus available as runoff is available in two recharge reservoirs through diversion
channels. Total water holding capacity is about 650000 cum & 40000 Cum beside that two injection wells also
constructed in these ponds. Considering 4 to 5 storms per season, this reservoir can hold a huge quantity of
water.
Taking 50% as the Average runoff coefficient runoff available has been calculated as under:
Page 369
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
50
Between 8000N to 5400N
Catchment area = 2326197 Sq.m.
Runoff coefficient = 50%
= 2326197 x 0.445 x 0.5
= 517579Cum.
Rainwater available at the foot of hill will be chanalised by drains and then diverted towards the recharge
reservoir of 40000 .
Expected recharge in mine area = 517579 x 0.70
= 362305 Cum/annum--------------- (B)
Anicut No -1, Near Village Bhimgarh
Anicut No 2:- Near Village Jawangarh
Anicut No 3 Near Village: Bagatpura
Anicut No 4 Near Village : Bher Ji Ki Dhani
Anicut No 5 Near Village : Khera
Anicut No 6 Near Village: Kanyakheri
Anicut No 7 Near Village: Nimbeti
TOTAL RAINWATER AVAILABLE IN THE STUDY AREA
= (A) + (B)
= 1568835 + 362305
= 1931140 Cum.
AQUIFER SYSTEM WITHIN 1 KM RADIUS AND ITS MANAGEMENT FOR RECHARGING
As per the hydrogeological study and hydrogeomorhic map of the area, following aquifer system occurs in 1 km
radius of the area.
1. Alluvial Aquifer
2. Hard rock Aquifer
Page 370
Ground Water Resources & Rainwater HarvestingSCL, RAS, JAITARAN, PALI
Associate Engineers & Consultants
51
The alluvial aquifer occurs only near the river trace & rest of the area occupied by hard rock aquifer, the alluvial
aquifer is most suitable for ground water recharge. In this area construction of bunds, subsurface dykes are
most suitable measure, beside that if possible constructor of recharge pond may also be feasible.
In hard rocks, like granites gneisses & mica schist ground water occurs in upper weathered zone & deep seated
fracture zone. In these rocks occurrence of deep seated fracture zones is very rare. Hence in this area for ground
water recharge, recharge ponds, open wells are most suitable structures.
As described in chapter 4, industry is already doing artificial recharge in nearby areas by means of construction,
rejuvenation of village ponds, check bunds & connecting open wells with the available rainwater runoff.
****
Page 371
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 1 1 16.9 46.3 3.2 225
15 3 1 2 16.3 47.4 2.3 230
15 3 1 3 16.0 48.1 0.5 315
15 3 1 4 15.3 50.6 0.0 360
15 3 1 5 15.9 50.5 0.3 360
15 3 1 6 16.9 49.7 2.5 270.3
15 3 1 7 16.5 47.3 4.3 220.4
15 3 1 8 16.3 45.8 3.2 312.5
15 3 1 9 17.2 43.2 0.7 230.1
15 3 1 10 17.3 42.7 3.2 225
15 3 1 11 19.2 42.1 1.6 45
15 3 1 12 21.6 41.5 0.9 337.5
15 3 1 13 24.8 41.1 1.2 215.4
15 3 1 14 25.3 40.6 0.0 90
15 3 1 15 26.0 40.2 2.6 45
15 3 1 16 25.5 39.5 0.8 315
15 3 1 17 23.2 40.3 1.3 312.5
15 3 1 18 21.6 40.6 3.1 225
15 3 1 19 20.4 43.4 0.0 270
15 3 1 20 19.8 44.5 0.2 225
15 3 1 21 19.2 45.6 0.5 90
15 3 1 22 17.1 46.3 0.0 130
15 3 1 23 17.0 48.4 2.3 220
15 3 1 24 16.9 48.9 0.3 157.5
15 3 2 1 16.2 49.2 0.0 157.5
15 3 2 2 16.4 49.7 0.2 225
15 3 2 3 15.3 50.2 0.0 247.5
15 3 2 4 15.2 50.6 0.5 218.3
15 3 2 5 16.9 52.4 0.0 360
15 3 2 6 17.6 54.6 0.9 220.5
15 3 2 7 17.3 53.1 1.3 225.3
15 3 2 8 18.6 56.7 0.3 225
15 3 2 9 18.3 55.3 0.1 270
15 3 2 10 19.4 53.8 0.6 215
15 3 2 11 20.5 50.6 0.5 182.3
15 3 2 12 20.7 48.6 0.1 360
15 3 2 13 21.6 30.6 0.3 230.1
15 3 2 14 22.4 33.8 3.2 225.4
15 3 2 15 23.8 29.1 0.5 90
15 3 2 16 24.0 29.4 6.2 225
15 3 2 17 23.1 30.6 2.6 230
15 3 2 18 22.6 39.5 1.3 272.3
15 3 2 19 22.1 38.1 2.8 280
15 3 2 20 19.5 40.6 0.0 22.5
15 3 2 21 18.3 41.8 0.2 157.5
15 3 2 22 17.6 42.6 0.6 157.5
15 3 2 23 16.6 50.6 0.0 156.2
15 3 2 24 16.3 52.9 0.0 157.5
15 3 3 1 15.4 60.9 1.6 270
15 3 3 2 14.6 70.6 0.0 135
15 3 3 3 14.5 73.6 2.4 46
15 3 3 4 14.3 84.2 1.5 48
15 3 3 5 14.1 80.6 1.3 45
15 3 3 6 13.9 69.6 1.9 45
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 3 7 14.4 60.6 0.0 337.5
15 3 3 8 14.9 52.3 0.0 157.5
15 3 3 9 15.6 50.7 0.0 135
15 3 3 10 16.7 49.6 2.3 230.1
15 3 3 11 18.4 40.2 0.1 135
15 3 3 12 20.8 39.4 0.0 67.5
15 3 3 13 23.5 38.6 0.0 45
15 3 3 14 26.7 32.1 1.6 225
15 3 3 15 27.1 33.6 0.3 315
15 3 3 16 25.3 30.6 0.0 80.2
15 3 3 17 24.6 27.6 0.0 75
15 3 3 18 24.2 29.6 2.7 225
15 3 3 19 22.0 33.8 3.2 230
15 3 3 20 21.3 36.9 1.9 312.5
15 3 3 21 20.3 40.9 0.0 157.5
15 3 3 22 19.6 52.9 0.0 292.5
15 3 3 23 19.4 59.1 1.3 315
15 3 3 24 18.2 60.9 0.0 157.5
15 3 4 1 16.2 66.3 1.6 270
15 3 4 2 15.3 69.2 1.8 225
15 3 4 3 15.2 70.6 2.3 215
15 3 4 4 14.6 72.6 0.0 178.4
15 3 4 5 14.3 76.6 0.0 45
15 3 4 6 14.0 69.1 0.0 112.5
15 3 4 7 15.6 53.6 3.2 275
15 3 4 8 16.9 40.3 0.0 157.5
15 3 4 9 17.2 39.2 1.2 265.1
15 3 4 10 19.3 29.4 0.0 157.5
15 3 4 11 20.2 30.6 1.5 225
15 3 4 12 22.6 25.9 3.2 220
15 3 4 13 24.9 20.6 2.6 215
15 3 4 14 26.4 18.6 0.0 312.5
15 3 4 15 28.3 17.9 0.8 67.5
15 3 4 16 27.7 17.2 0.0 315
15 3 4 17 26.4 26.1 0.3 360
15 3 4 18 25.3 25.7 1.0 225
15 3 4 19 22.7 35.9 0.0 337.5
15 3 4 20 21.5 40.9 1.5 218
15 3 4 21 17.9 49.2 1.6 225
15 3 4 22 16.3 50.6 2.1 225
15 3 4 23 15.2 55.6 0.0 135
15 3 4 24 15.3 56.9 2.3 230.1
15 3 5 1 15.4 60.7 2.6 270
15 3 5 2 14.6 66.5 0.0 337.5
15 3 5 3 14.2 70.6 0.7 157.5
15 3 5 4 13.6 79.2 0.2 157.5
15 3 5 5 12.2 60.9 0.5 157.5
15 3 5 6 13.6 50.9 3.3 225.7
15 3 5 7 14.6 45.6 0.0 360
15 3 5 8 16.2 40.9 0.1 135
15 3 5 9 17.2 38.74 0.2 182.3
15 3 5 10 18.6 33.9 0.0 157.5
15 3 5 11 19.3 30.6 0.7 67.5
15 3 5 12 22.3 29.7 2.3 220
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 5 13 23.6 28.1 1.5 225
15 3 5 14 23.4 22.7 0.6 292.5
15 3 5 15 24.9 25.9 0.7 247.5
15 3 5 16 26.4 23.4 0.6 292.5
15 3 5 17 28.1 20.7 1.5 230
15 3 5 18 26.2 26.9 1.4 215.7
15 3 5 19 25.1 29.1 2.3 315
15 3 5 20 24.2 33.5 1.1 225
15 3 5 21 23.9 39.7 1.3 230.4
15 3 5 22 22.1 43.8 0.7 45
15 3 5 23 21.0 40.6 2.3 90
15 3 5 24 20.9 49.1 1.9 225
15 3 6 1 19.6 50.3 3.3 220.3
15 3 6 2 17.3 60.3 2.7 225.7
15 3 6 3 16.4 63.69 0.0 337.5
15 3 6 4 15.6 78.6 0.0 247.5
15 3 6 5 14.7 75 0.0 247.5
15 3 6 6 15.3 60.9 0.0 315
15 3 6 7 16.5 59.5 0.0 315
15 3 6 8 18.9 50.6 0.0 50
15 3 6 9 19.0 43..6 2.3 45
15 3 6 10 22.1 33.8 0.0 360
15 3 6 11 22.6 30.9 0.0 360
15 3 6 12 24.6 29.4 0.5 45
15 3 6 13 28.3 28.6 2.6 225
15 3 6 14 30.1 26.2 2.5 270.5
15 3 6 15 30.5 25.6 3.2 230
15 3 6 16 29.4 22.6 0.3 215.3
15 3 6 17 24.3 23.4 2.1 225
15 3 6 18 24.0 35.9 0.9 215
15 3 6 19 21.3 40.9 1.3 225
15 3 6 20 20.9 46.6 2.4 225
15 3 6 21 19.3 50.1 0.5 46
15 3 6 22 18.4 59.9 0.8 45
15 3 6 23 17.6 63.5 1.2 220.1
15 3 6 24 16.2 69.5 0.0 360
15 3 7 1 16.9 50.3 0.0 135
15 3 7 2 16.5 60.3 0.0 135
15 3 7 3 16.1 63.69 0.0 157.5
15 3 7 4 16.0 68.1 0.0 157.5
15 3 7 5 15.4 59.1 1.2 271
15 3 7 6 15.2 60.9 0.0 360
15 3 7 7 17.6 59.5 0.0 360
15 3 7 8 18.3 50.6 0.0 172.5
15 3 7 9 18.9 43..6 3.2 275
15 3 7 10 22.6 33.8 0.0 90
15 3 7 11 23.1 30.9 0.0 45
15 3 7 12 24.3 29.4 0.0 157.5
15 3 7 13 28.3 28.6 0.6 175.4
15 3 7 14 30.6 26.2 1.6 215
15 3 7 15 27.4 25.6 4.2 225
15 3 7 16 27.3 22.6 0.6 45
15 3 7 17 26.2 19.2 1.3 219.2
15 3 7 18 25.8 35.9 3.2 225.3
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 7 19 25.3 40.9 0.3 45
15 3 7 20 24.7 46.6 0.7 45
15 3 7 21 24.3 50.1 5.0 225
15 3 7 22 23.2 59.9 0.2 270
15 3 7 23 20.3 63.5 0.3 270
15 3 7 24 19.6 69.5 0.0 312.5
15 3 8 1 18.3 63.4 2.0 215
15 3 8 2 17.6 66.2 2.3 225
15 3 8 3 17.8 59.2 0.5 35
15 3 8 4 17.1 57.2 3.6 272.3
15 3 8 5 16.0 55.1 2.5 230.1
15 3 8 6 16.9 53.6 0.0 80
15 3 8 7 17.6 48.2 1.6 225
15 3 8 8 17.2 43.2 0.0 247.5
15 3 8 9 18.6 39.1 3.6 226.4
15 3 8 10 19.2 33.2 1.8 225
15 3 8 11 20.6 29.2 1.6 45
15 3 8 12 23.9 28.8 0.9 45
15 3 8 13 26.2 30.9 1.2 225
15 3 8 14 30.3 33.7 0.0 112.5
15 3 8 15 29.4 20.6 2.6 219.4
15 3 8 16 29.1 19.8 3.2 225
15 3 8 17 27.6 17.6 2.8 230.1
15 3 8 18 26.1 29.6 3.1 275
15 3 8 19 25.9 37.6 0.0 67.5
15 3 8 20 24.6 39.1 0.0 45
15 3 8 21 23.1 43.9 0.5 270
15 3 8 22 22.1 47.1 1.6 45
15 3 8 23 21.9 44.6 2.3 225
15 3 8 24 20.3 39.4 1.3 230
15 3 9 1 19.6 33.6 2.6 270
15 3 9 2 18.7 39.7 1.2 157.5
15 3 9 3 17.1 40.9 1.6 157.5
15 3 9 4 17.6 41.6 0.5 45
15 3 9 5 16.2 40.9 0.8 292.5
15 3 9 6 17.4 38.6 3.2 225
15 3 9 7 18.6 39.1 1.3 219.2
15 3 9 8 19.2 33.6 1.2 247.5
15 3 9 9 20.6 30.6 2.3 270
15 3 9 10 21.3 29.4 0.8 112.5
15 3 9 11 22.7 28.1 0.5 157.5
15 3 9 12 23.6 22.6 0.2 270
15 3 9 13 27.3 20.6 6.2 225
15 3 9 14 29.8 19.4 1.2 218
15 3 9 15 29.2 18.6 0.5 247.5
15 3 9 16 27.4 15.5 1.8 225
15 3 9 17 25.0 13.8 1.5 225
15 3 9 18 20.4 12.8 1.3 230
15 3 9 19 19.5 16.5 0.2 247.5
15 3 9 20 18.6 20.9 1.3 45
15 3 9 21 18.3 23.9 1.5 45
15 3 9 22 18.2 28.7 0.6 230.2
15 3 9 23 17.3 30.9 0.0 247.5
15 3 9 24 16.7 39.4 1.5 270
Page 372
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 10 1 16.4 32.8 1.2 45
15 3 10 2 16.2 31.6 2.1 292.5
15 3 10 3 15.6 39.2 3.2 270
15 3 10 4 15.3 40.6 1.2 360
15 3 10 5 13.8 48.9 2.1 45
15 3 10 6 14.6 40.6 0.0 360
15 3 10 7 15.7 39.8 0.0 337.5
15 3 10 8 16.9 32.1 2.1 247.5
15 3 10 9 18.2 29.5 1.3 270
15 3 10 10 19.4 25.6 1.8 235
15 3 10 11 21.5 23.1 1.5 45
15 3 10 12 23.7 22.9 0.0 360
15 3 10 13 28.1 29.2 1.3 270.3
15 3 10 14 30.3 26.3 0.6 185.2
15 3 10 15 28.4 24.1 2.1 272
15 3 10 16 27.6 20.9 0.0 292.5
15 3 10 17 25.6 22.9 1.5 179.6
15 3 10 18 26.2 23.7 1.8 225
15 3 10 19 23.1 33.9 0.9 45
15 3 10 20 22.9 39.1 0.2 360
15 3 10 21 21.0 40.9 1.3 22.5
15 3 10 22 20.0 43.5 0.0 360
15 3 10 23 19.6 44.6 0.0 360
15 3 10 24 18.4 46.1 2.1 337.5
15 3 11 1 17.3 49.5 1.2 292.5
15 3 11 2 16.4 46.2 1.8 225
15 3 11 3 15.3 44.9 2.3 230
15 3 11 4 14.2 50.1 3.2 247.5
15 3 11 5 13.2 49.5 1.5 45
15 3 11 6 14.6 40.9 0.0 337.5
15 3 11 7 15.6 39.5 1.6 225
15 3 11 8 16.8 32.6 1.2 312.5
15 3 11 9 19.6 30.9 1.2 270
15 3 11 10 20.4 29.1 0.0 90
15 3 11 11 23.6 23.1 0.9 230.3
15 3 11 12 24.3 20.9 0.9 216.4
15 3 11 13 25.6 19.5 0.8 220.1
15 3 11 14 26.1 17.6 1.5 292.5
15 3 11 15 27.3 15.9 0.8 215
15 3 11 16 28.1 19 0.3 360
15 3 11 17 30.2 23.8 0.3 45
15 3 11 18 29.1 29.4 1.5 230
15 3 11 19 27.6 33.6 0.0 360
15 3 11 20 26.4 39.1 2.9 230
15 3 11 21 23.5 43.8 1.2 90
15 3 11 22 21.4 49.1 1.9 67.5
15 3 11 23 20.6 45.6 1.2 312.5
15 3 11 24 20.3 49.2 0.5 45
15 3 12 1 19.7 49.2 2.6 225
15 3 12 2 17.9 50.3 1.3 157.5
15 3 12 3 17.4 51.9 0.7 270
15 3 12 4 17.2 52.9 1.9 225
15 3 12 5 17.0 48.1 0.5 45
15 3 12 6 18.6 46.2 3.3 45
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 12 7 19.0 40.7 1.3 312.5
15 3 12 8 19.9 32.9 3.2 247.5
15 3 12 9 20.4 30.9 2.9 247.5
15 3 12 10 21.3 29.7 0.0 186.4
15 3 12 11 23.5 26.2 1.6 224.5
15 3 12 12 26.8 26.7 0.5 175.3
15 3 12 13 30.4 29.4 1.5 112.5
15 3 12 14 34.1 30.6 1.6 112.5
15 3 12 15 32.5 27.6 0.0 360
15 3 12 16 31.2 26.8 1.3 260
15 3 12 17 30.4 25.1 1.5 270
15 3 12 18 29.5 29.7 1.4 245.2
15 3 12 19 24.9 33.7 2.0 45
15 3 12 20 21.0 36.9 1.1 225
15 3 12 21 20.6 39.1 1.3 360
15 3 12 22 18.4 42.6 0.3 22.5
15 3 12 23 18.4 45.9 0.4 90
15 3 12 24 18.0 50.9 0.2 230
15 3 13 1 19.5 69.2 3.3 225
15 3 13 2 18.6 70.9 3.2 230
15 3 13 3 18.4 88.6 1.2 80
15 3 13 4 18.1 92.7 0.0 65
15 3 13 5 18.0 85.1 1.5 270
15 3 13 6 18.2 80.6 0.6 226.1
15 3 13 7 20.6 78.6 1.5 223.9
15 3 13 8 21.3 76.4 2.4 220.5
15 3 13 9 22.6 73.1 1.6 270
15 3 13 10 23.5 70.6 2.1 185
15 3 13 11 25.6 69.2 1.2 135
15 3 13 12 26.5 68.4 0.5 135
15 3 13 13 27.1 60.9 2.6 230
15 3 13 14 30.8 50.6 0.0 360
15 3 13 15 34.5 49.5 0.6 216
15 3 13 16 28.4 40.6 0.5 210
15 3 13 17 26.1 35.6 2.1 225
15 3 13 18 25.6 33.2 0.9 232
15 3 13 19 23.2 46.1 1.6 270
15 3 13 20 20.9 48.9 0.7 223.1
15 3 13 21 19.6 50.6 0.5 67.5
15 3 13 22 19.4 63.1 0.8 67.5
15 3 13 23 19.3 69.2 1.2 225
15 3 13 24 19.1 73.2 1.6 247.5
15 3 14 1 18.6 79.2 0.3 270
15 3 14 2 18.2 80.1 1.6 225
15 3 14 3 17.4 86.3 2.1 225
15 3 14 4 17.2 90.4 1.6 225
15 3 14 5 17.1 79.1 0.4 270
15 3 14 6 18.5 73.1 0.5 270
15 3 14 7 20.6 70 4.0 45
15 3 14 8 21.4 68.6 2.1 45
15 3 14 9 23.6 65.1 1.2 45
15 3 14 10 23.4 60.9 1.9 225
15 3 14 11 24.6 59.3 2.5 230
15 3 14 12 29.3 56.2 1.2 218
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 14 13 26.1 53.4 0.6 215
15 3 14 14 27.6 52..6 1.2 225
15 3 14 15 27.3 54.9 1.4 90
15 3 14 16 28.4 52.1 0.6 135
15 3 14 17 28.3 51.9 1.3 67.5
15 3 14 18 26.1 59.1 1.0 225
15 3 14 19 23.2 64.2 0.3 45
15 3 14 20 22.1 68.1 0.7 22.5
15 3 14 21 20.3 72.6 5.0 225
15 3 14 22 19.5 76.1 2.3 45
15 3 14 23 19.0 77.9 3.1 48
15 3 14 24 18.9 80.2 0.0 42
15 3 15 1 18.0 81.6 0.6 48
15 3 15 2 17.9 83.2 0.9 312
15 3 15 3 17.6 84.9 0.7 318
15 3 15 4 16.0 85.7 2.3 315
15 3 15 5 16.9 80 1.2 270
15 3 15 6 17.5 76.2 1.3 230
15 3 15 7 18.3 65.1 1.5 225
15 3 15 8 19.4 50.6 2.3 225
15 3 15 9 20.6 49.5 0.0 337.5
15 3 15 10 20.6 41.1 0.0 360
15 3 15 11 21.4 39.2 1.2 45
15 3 15 12 24.5 35.4 1.6 50
15 3 15 13 27.3 33.2 0.9 225
15 3 15 14 30.4 30.9 1.2 90
15 3 15 15 28.9 28.7 2.3 45
15 3 15 16 27.5 26.4 1.9 45
15 3 15 17 27.2 20.4 2.1 360
15 3 15 18 25.0 29 0.6 360
15 3 15 19 24.3 49.7 0.0 360
15 3 15 20 22.5 53.7 0.5 360
15 3 15 21 21.3 59.1 1.2 45
15 3 15 22 20.7 63.7 2.5 90
15 3 15 23 20.4 69.2 2.5 225
15 3 15 24 20.1 76.9 2.9 225
15 3 16 1 19.6 81.6 3.2 43
15 3 16 2 19.2 83.2 1.2 157.5
15 3 16 3 18.8 84.9 0.7 157.5
15 3 16 4 18.6 87.2 3.3 45
15 3 16 5 17.9 80 3.2 270
15 3 16 6 18.2 76.2 0.0 360
15 3 16 7 19.5 65.1 1.3 45
15 3 16 8 20.1 50.6 0.0 337.5
15 3 16 9 20.6 49.5 1.6 270
15 3 16 10 21.3 41.1 0.5 337.5
15 3 16 11 23.6 39.2 1.0 22.5
15 3 16 12 25.4 35.4 0.7 270
15 3 16 13 28.5 33.2 0.0 185
15 3 16 14 30.3 30.9 2.3 178
15 3 16 15 31.5 28.7 1.4 182
15 3 16 16 30.4 26.4 1.3 225
15 3 16 17 28.0 21.8 1.6 220
15 3 16 18 27.6 29 3.3 360
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 16 19 25.3 49.7 0.0 176.5
15 3 16 20 25.1 53.7 1.2 45
15 3 16 21 24.7 59.1 0.8 22.5
15 3 16 22 23.4 63.7 0.7 360
15 3 16 23 21.5 69.2 1.6 45
15 3 16 24 20.2 76.9 1.3 225
15 3 17 1 19.6 69.2 0.9 225
15 3 17 2 19.1 63.1 3.0 45
15 3 17 3 18.9 59.8 0.7 225
15 3 17 4 18.6 50.7 2.5 225
15 3 17 5 18.2 49.3 1.2 225
15 3 17 6 18.0 47.1 1.6 225
15 3 17 7 18.6 44.2 2.5 315
15 3 17 8 19.2 40.8 1.3 310
15 3 17 9 20.6 38.1 1.6 312
15 3 17 10 21.6 36.7 1.5 45
15 3 17 11 23.6 33 3.2 310
15 3 17 12 28.2 29.8 2.7 270
15 3 17 13 30.4 28.1 1.2 270
15 3 17 14 29.7 28.9 2.9 270
15 3 17 15 27.6 26.1 1.5 315
15 3 17 16 25.1 25.1 1.2 45
15 3 17 17 26.0 22.9 1.0 48
15 3 17 18 23.0 21.9 0.9 43
15 3 17 19 22.1 31.7 0.8 45
15 3 17 20 20.6 29.6 0.4 45
15 3 17 21 19.8 30.9 1.5 186.2
15 3 17 22 19.4 37.9 2.5 360
15 3 17 23 18.3 40.9 1.2 270
15 3 17 24 18.1 49.8 1.6 270
15 3 18 1 17.8 55.9 1.3 270
15 3 18 2 17.6 59.1 1.5 275
15 3 18 3 17.1 60.3 2.3 260
15 3 18 4 16.8 68.4 1.5 360
15 3 18 5 16.4 69.1 1.3 247.5
15 3 18 6 16.9 73.9 1.6 315
15 3 18 7 18.9 79.1 3.2 310
15 3 18 8 20.6 69.2 1.5 275
15 3 18 9 21.6 63.4 0.9 270
15 3 18 10 23.9 33.9 1.5 250
15 3 18 11 24.8 29.4 1.3 270
15 3 18 12 26.5 20.8 1.6 320
15 3 18 13 28.0 19.2 2.3 333
15 3 18 14 32.3 17.6 0.4 360
15 3 18 15 28.6 15.9 1.2 270
15 3 18 16 29.4 12.7 1.1 265
15 3 18 17 28.1 10.9 0.8 320.2
15 3 18 18 28.3 19.5 0.7 230
15 3 18 19 27.0 20.9 1.2 187.2
15 3 18 20 26.1 29.8 2.3 270
15 3 18 21 25.6 39.7 2.5 265
15 3 18 22 25.1 40.9 3.1 315
15 3 18 23 24.7 43.9 0.6 315
15 3 18 24 24.2 46.8 1.3 270
Page 373
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 19 1 23.8 48.1 1.9 360
15 3 19 2 23.5 53.1 0.0 337.5
15 3 19 3 22.9 56.9 4.5 225
15 3 19 4 22.3 59.1 3.6 225
15 3 19 5 22.1 55.1 0.7 45
15 3 19 6 21.8 50.9 1.6 45
15 3 19 7 21.6 40.9 1.9 45
15 3 19 8 21.3 38.1 2.1 48
15 3 19 9 21.2 36.2 0.7 50
15 3 19 10 24.3 30.9 2.5 270
15 3 19 11 26.7 25.6 2.0 265
15 3 19 12 28.4 22 2.1 268
15 3 19 13 32.6 19.7 1.9 270
15 3 19 14 36.4 15.2 1.5 315
15 3 19 15 38.5 13.9 1.1 315
15 3 19 16 38.3 12.7 2.3 174.2
15 3 19 17 35.4 10.9 0.0 270
15 3 19 18 32.6 16.9 0.0 45
15 3 19 19 31.8 19.7 0.4 90
15 3 19 20 30.6 23.6 1.2 221.2
15 3 19 21 29.5 29.7 1.6 225.6
15 3 19 22 28.4 33.9 1.5 270
15 3 19 23 27.2 36.7 1.3 315
15 3 19 24 26.5 39.1 2.1 45
15 3 20 1 26.1 42.4 0.8 270
15 3 20 2 25.8 49.1 0.9 312.5
15 3 20 3 25.3 52.8 1.3 225
15 3 20 4 25.1 61.9 0.0 45.6
15 3 20 5 24.8 50.9 0.0 337.5
15 3 20 6 24.3 49.8 1.6 225
15 3 20 7 24.9 43.7 0.0 42.3
15 3 20 8 25.2 39.7 2.3 225
15 3 20 9 26.4 35.1 0.0 43.2
15 3 20 10 28.5 33.9 2.8 225
15 3 20 11 29.6 36.1 0.0 112.5
15 3 20 12 32.3 29.7 2.1 90
15 3 20 13 36.7 23.4 0.3 67.5
15 3 20 14 39.5 20.9 1.6 90
15 3 20 15 38.4 18.6 0.0 67.5
15 3 20 16 33.6 15.9 0.6 90
15 3 20 17 34.0 11.9 0.5 90
15 3 20 18 32.0 16.9 0.6 360
15 3 20 19 30.0 19.7 0.6 67.5
15 3 20 20 29.4 23.8 0.7 270.5
15 3 20 21 28.7 26.7 3.3 90
15 3 20 22 27.6 39.4 0.0 67.5
15 3 20 23 27.3 43.9 0.0 270
15 3 20 24 26.7 40.6 3.1 360
15 3 21 1 26.4 48.7 0.7 360
15 3 21 2 26.1 50.9 0.8 270
15 3 21 3 25.9 51.9 0.0 247.5
15 3 21 4 25.7 52.7 0.0 247.5
15 3 21 5 24.8 53.9 1.2 45
15 3 21 6 24.9 55.9 1.5 225
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 21 7 26.3 49.7 0.0 270
15 3 21 8 28.1 45.1 0.2 270
15 3 21 9 30.2 43.9 1.3 292.5
15 3 21 10 32.5 39.7 0.0 360
15 3 21 11 35.6 35.8 0.0 67.5
15 3 21 12 36.4 30.9 1.0 45
15 3 21 13 37.2 29.1 1.5 230
15 3 21 14 38.2 32.5 0.6 185
15 3 21 15 37.4 22.9 2.4 173
15 3 21 16 37.9 18.9 1.6 225.5
15 3 21 17 37.3 15.9 3.1 156
15 3 21 18 36.4 12.1 1.3 230.1
15 3 21 19 35.7 20.9 2.3 231
15 3 21 20 34.1 33.4 1.5 220.1
15 3 21 21 33.2 29.7 0.0 360
15 3 21 22 32.7 25.9 1.5 270
15 3 21 23 32.1 32.9 0.9 270
15 3 21 24 31.5 40.6 0.6 125.8
15 3 22 1 30.4 48.7 1.3 45
15 3 22 2 29.7 50.9 2.7 48
15 3 22 3 29.4 51.9 1.2 46
15 3 22 4 28.6 52.7 1.3 48
15 3 22 5 26.3 53.9 0.0 337.5
15 3 22 6 27.0 62.2 2.3 225
15 3 22 7 28.5 49.7 1.1 247.5
15 3 22 8 28.9 45.1 0.0 337.5
15 3 22 9 27.4 43.9 0.9 270
15 3 22 10 29.6 39.7 1.5 315
15 3 22 11 29.2 35.8 3.3 22.5
15 3 22 12 30.6 30.9 1.4 135
15 3 22 13 31.4 29.1 0.8 210.5
15 3 22 14 34.6 32.5 0.6 337.5
15 3 22 15 36.9 22.9 2.2 127.5
15 3 22 16 35.9 18.9 0.0 135
15 3 22 17 36.1 15.9 1.6 225
15 3 22 18 35.9 12.1 0.6 360
15 3 22 19 31.2 20.9 1.5 225
15 3 22 20 30.6 33.4 1.6 230
15 3 22 21 30.4 29.7 1.2 112.5
15 3 22 22 29.6 25.9 0.6 157.5
15 3 22 23 29.4 32.9 0.8 270
15 3 22 24 28.5 40.6 0.6 225
15 3 23 1 27.3 41.9 1.3 312.5
15 3 23 2 27.1 42.6 1.2 270
15 3 23 3 26.6 43.8 1.8 225
15 3 23 4 26.3 46.7 0.6 270
15 3 23 5 25.7 47.9 1.2 230
15 3 23 6 25.2 43.0 2.3 218
15 3 23 7 26.4 39.7 0.9 225
15 3 23 8 26.7 35.6 1.3 231
15 3 23 9 27.1 30.2 2.5 230
15 3 23 10 30.2 29.6 1.9 225
15 3 23 11 31.6 22.7 1.3 221
15 3 23 12 32.0 19.8 0.8 67.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 23 13 33.4 18.9 2.7 112.5
15 3 23 14 34.6 15.0 1.5 45
15 3 23 15 35.1 12.9 1.4 360
15 3 23 16 36.2 10.6 2.4 316.2
15 3 23 17 35.6 9.2 1.5 45
15 3 23 18 34.1 15.9 2.0 320.7
15 3 23 19 32.4 20.9 1.0 112.5
15 3 23 20 31.6 36.7 1.1 67.5
15 3 23 21 30.1 46.9 0.6 112.5
15 3 23 22 29.5 47.3 1.3 112.5
15 3 23 23 28.4 40.9 1.3 157.5
15 3 23 24 27.3 39.4 0.5 247.5
15 3 24 1 26.5 41.9 1.2 312.5
15 3 24 2 26.2 42.6 1.7 247.5
15 3 24 3 25.4 43.8 1.6 219
15 3 24 4 24.3 46.7 2.3 225
15 3 24 5 24.1 47.9 2.8 215
15 3 24 6 24.6 43.0 1.5 218
15 3 24 7 25.7 39.7 1.7 270
15 3 24 8 26.4 35.6 1.1 225
15 3 24 9 27.5 30.2 0.0 43.2
15 3 24 10 28.9 29.6 3.2 270
15 3 24 11 30.6 22.7 0.7 90
15 3 24 12 33.5 19.8 0.6 22.5
15 3 24 13 35.6 18.9 2.4 112.5
15 3 24 14 38.4 15.0 1.7 225
15 3 24 15 37.8 12.9 2.8 360
15 3 24 16 36.3 10.6 1.3 45
15 3 24 17 35.2 8.4 2.3 50
15 3 24 18 34.7 15.9 1.5 52
15 3 24 19 32.4 20.9 1.9 45
15 3 24 20 31.6 36.7 1.3 90
15 3 24 21 30.5 46.9 1.8 45
15 3 24 22 29.3 47.3 1.5 48
15 3 24 23 26.0 40.9 2.3 225
15 3 24 24 25.6 39.4 3.2 45
15 3 25 1 23.6 32.9 1.2 292.5
15 3 25 2 23.9 33.7 0.7 135
15 3 25 3 23.7 35.9 1.5 45
15 3 25 4 23.6 36.7 0.5 49
15 3 25 5 23.4 35.1 0.9 45
15 3 25 6 23.6 30.9 1.2 45
15 3 25 7 26.1 29.7 0.0 53.1
15 3 25 8 27.8 25.9 1.3 270
15 3 25 9 28.1 26.4 1.5 268
15 3 25 10 29.0 22.1 2.1 225
15 3 25 11 30.6 20.9 1.0 22.5
15 3 25 12 31.3 16.8 1.3 225
15 3 25 13 32.4 19.1 1.2 292.5
15 3 25 14 33.6 15.2 0.7 247.5
15 3 25 15 35.6 13.4 3.2 270
15 3 25 16 37.1 12.7 3.3 292.5
15 3 25 17 33.2 11.9 0.5 22.5
15 3 25 18 32.1 15.9 1.5 315
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 25 19 30.6 19.7 2.3 22.5
15 3 25 20 29.5 20.9 0.8 67.5
15 3 25 21 28.4 26.7 1.5 90
15 3 25 22 27.6 29.1 1.8 46
15 3 25 23 26.1 30.7 1.3 48
15 3 25 24 25.3 33.7 3.2 225
15 3 26 1 25.0 34.6 2.1 220
15 3 26 2 24.6 36.7 1.8 215
15 3 26 3 24.4 38.1 1.3 225
15 3 26 4 24.0 45.2 2.1 225
15 3 26 5 23.9 48.9 1.6 228
15 3 26 6 24.6 36.2 1.5 45
15 3 26 7 26.1 33.7 0.7 337.5
15 3 26 8 27.3 30.9 1.4 312.5
15 3 26 9 28.9 26.8 1.9 157.5
15 3 26 10 30.2 20.9 1.8 157.5
15 3 26 11 32.6 19.4 2.5 135
15 3 26 12 34.5 18.2 1.1 56.2
15 3 26 13 36.8 15.6 1.2 90
15 3 26 14 39.3 14.3 1.4 292.5
15 3 26 15 38.6 13.8 1.2 90
15 3 26 16 38.1 12.0 1.6 247.5
15 3 26 17 37.0 16.9 2.5 45
15 3 26 18 36.0 15.7 0.8 45
15 3 26 19 33.2 19.0 1.6 50
15 3 26 20 30.1 22.9 1.2 337.5
15 3 26 21 29.4 29.0 0.8 112.5
15 3 26 22 28.3 33.7 1.5 90
15 3 26 23 27.6 39.9 1.5 112.5
15 3 26 24 26.4 43.7 0.7 312.5
15 3 27 1 26.1 40.9 1.3 45
15 3 27 2 25.9 39.2 1.5 247.5
15 3 27 3 26.2 36.1 0.4 225
15 3 27 4 25.6 33.8 3.2 312.5
15 3 27 5 25.4 29.1 4.6 270
15 3 27 6 24.6 22.4 5.2 270
15 3 27 7 25.9 19.3 0.5 90
15 3 27 8 26.1 15.1 1.2 112.5
15 3 27 9 27.3 14.9 1.8 135
15 3 27 10 28.9 19.2 0.8 135
15 3 27 11 30.6 16.9 2.6 112.5
15 3 27 12 32.6 20.9 1.9 112.5
15 3 27 13 35.5 22.0 0.6 225
15 3 27 14 38.9 18.6 2.4 157.5
15 3 27 15 39.3 16.3 2.6 225
15 3 27 16 37.4 12.6 1.7 45
15 3 27 17 37.0 17.9 1.1 45
15 3 27 18 35.1 20.3 1.1 45
15 3 27 19 34.0 29.1 1.4 90
15 3 27 20 30.9 30.7 0.8 90
15 3 27 21 29.1 33.9 1.5 215
15 3 27 22 28.3 36.7 2.3 230
15 3 27 23 27.1 33.2 2.5 220
15 3 27 24 26.5 30.9 0.0 215
Page 374
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 28 1 25.0 39.7 1.3 315
15 3 28 2 24.6 40.9 0.6 225
15 3 28 3 24.3 43.1 0.7 225
15 3 28 4 24.0 44.9 0.4 112.5
15 3 28 5 23.5 40.9 0.0 292.5
15 3 28 6 25.6 37.1 2.6 270
15 3 28 7 26.9 36.1 1.3 135
15 3 28 8 28.1 29.9 1.5 157.5
15 3 28 9 29.3 28.1 0.7 45
15 3 28 10 30.1 20.9 1.0 337.5
15 3 28 11 32.9 19.7 0.7 67.5
15 3 28 12 34.6 18.1 1.3 270
15 3 28 13 35.6 15.6 0.7 45
15 3 28 14 36.9 13.7 1.8 45
15 3 28 15 37.8 12.9 2.5 270
15 3 28 16 37.6 8.4 1.0 45
15 3 28 17 36.4 15.9 0.9 270
15 3 28 18 35.1 16.7 0.6 270
15 3 28 19 30.2 19.0 0.7 360
15 3 28 20 28.0 26.6 1.4 22.5
15 3 28 21 27.6 27.0 1.9 22.5
15 3 28 22 26.1 33.8 1.2 270
15 3 28 23 25.3 36.0 1.9 265
15 3 28 24 25.9 39.7 0.5 270
15 3 29 1 25.1 35.6 0.6 45
15 3 29 2 24.6 33.2 0.9 45
15 3 29 3 25.1 29.1 2.4 45
15 3 29 4 26.2 23.8 0.0 292.5
15 3 29 5 26.6 22.8 1.2 312.5
15 3 29 6 26.4 20.9 0.0 182.3
15 3 29 7 26.9 19.7 0.0 292.5
15 3 29 8 28.6 20.9 0.0 337.5
15 3 29 9 29.3 21.6 3.9 225
15 3 29 10 30.4 20.9 0.0 45
15 3 29 11 32.6 18.4 1.3 337.5
15 3 29 12 31.3 15.6 1.2 90
15 3 29 13 33.5 14.6 1.5 45
15 3 29 14 36.8 12.9 1.3 112.5
15 3 29 15 38.4 11.9 1.4 135
15 3 29 16 35.1 9.2 2.1 247.5
15 3 29 17 34.6 16.9 1.7 22.5
15 3 29 18 33.2 19.0 0.0 67.5
15 3 29 19 32.1 20.9 3.3 67.5
15 3 29 20 29.4 17.6 1.5 230
15 3 29 21 26.3 21.1 1.6 270
15 3 29 22 25.1 22.6 2.5 265
15 3 29 23 24.9 20.7 2.3 250
15 3 29 24 24.6 21.9 1.6 271
15 3 30 1 24.0 28.8 1.2 275
15 3 30 2 23.7 29.1 1.3 270
15 3 30 3 23.4 31.9 1.6 265
15 3 30 4 23.1 32.2 2.8 270
15 3 30 5 23.4 30.6 2.5 270
15 3 30 6 23.6 30.6 2.9 225
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 3 30 7 25.2 29.7 1.9 225
15 3 30 8 25.9 25.7 2.1 230
15 3 30 9 26.4 21.1 1.5 225
15 3 30 10 28.3 19.7 0.6 230
15 3 30 11 30.2 17.6 1.6 218
15 3 30 12 31.6 15.2 1.6 90
15 3 30 13 32.6 13.0 0.6 67.5
15 3 30 14 36.4 10.8 0.3 157.5
15 3 30 15 34.2 9.7 1.3 90
15 3 30 16 33.5 8.0 1.6 225
15 3 30 17 32.8 13.4 1.5 230
15 3 30 18 31.2 16.6 1.4 90
15 3 30 19 30.4 19.9 1.3 22.5
15 3 30 20 29.3 27.6 0.0 22.5
15 3 30 21 28.1 26.4 0.0 90
15 3 30 22 27.4 23.8 2.3 50
15 3 30 23 27.2 29.8 1.5 157.5
15 3 30 24 26.5 30.3 2.3 45
15 3 31 1 26.3 28.8 1.5 360
15 3 31 2 26.1 29.1 1.9 270
15 3 31 3 25.8 31.9 0.8 270
15 3 31 4 25.4 32.2 2.1 312.5
15 3 31 5 24.6 39.4 3.0 310.5
15 3 31 6 24.3 30.6 2.8 270
15 3 31 7 25.6 29.7 0.6 270
15 3 31 8 25.9 25.7 1.2 270
15 3 31 9 26.4 21.1 4.1 315
15 3 31 10 28.6 19.7 1.5 360
15 3 31 11 30.6 17.6 0.7 135
15 3 31 12 31.2 15.2 1.8 135
15 3 31 13 34.5 13.0 3.6 90
15 3 31 14 37.1 10.8 3.6 67.5
15 3 31 15 36.4 9.7 3.4 315
15 3 31 16 35.3 8.0 1.5 270
15 3 31 17 33.0 13.4 2.1 315
15 3 31 18 30.3 16.6 1.4 40.5
15 3 31 19 28.6 19.9 0.6 337.5
15 3 31 20 27.6 27.6 0.0 315
15 3 31 21 26.3 26.4 0.4 337.5
15 3 31 22 25.8 23.8 3.2 45
15 3 31 23 25.4 29.8 1.5 135
15 3 31 24 24.7 30.3 2.1 337.5
15 4 1 1 21.4 33.1 2.3 157.5
15 4 1 2 21.6 34.9 2.1 337.5
15 4 1 3 22.3 38.4 1.9 270
15 4 1 4 21.6 39.1 0.7 312.5
15 4 1 5 20.3 36.6 0.6 312.5
15 4 1 6 21.3 32.8 0.6 270
15 4 1 7 22.3 30.9 1.5 360
15 4 1 8 23.4 28.7 2.3 22.5
15 4 1 9 25.3 25.1 1.2 292.5
15 4 1 10 28.3 24.9 3.3 225
15 4 1 11 29.1 22.0 0.7 90
15 4 1 12 30.1 20.9 1.3 90
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 1 13 31.6 17.6 1.4 135
15 4 1 14 32.6 12.7 1.7 135
15 4 1 15 35.6 10.9 3.6 53.2
15 4 1 16 36.1 8.2 1.7 42.3
15 4 1 17 35.1 9.9 0.5 67.5
15 4 1 18 34.3 16.5 1.7 22.5
15 4 1 19 33.2 19.7 2.1 360
15 4 1 20 32.1 20.6 2.3 275
15 4 1 21 30.3 26.3 0.9 67.5
15 4 1 22 29.1 29.1 3.3 270
15 4 1 23 28.4 30.7 2.1 225
15 4 1 24 26.5 32.9 0.6 223.4
15 4 2 1 25.1 38.7 3.2 270
15 4 2 2 24.3 35.1 1.5 157.5
15 4 2 3 23.1 34.6 0.5 157.5
15 4 2 4 22.3 40.1 1.5 67.5
15 4 2 5 22.6 35.6 1.2 315
15 4 2 6 23.0 32.7 1.3 315
15 4 2 7 24.6 29.0 1.3 270
15 4 2 8 25.6 21.0 3.2 265
15 4 2 9 26.1 30.9 1.6 225
15 4 2 10 27.8 31.6 3.2 45
15 4 2 11 29.0 30.9 0.7 157.5
15 4 2 12 30.6 29.1 2.7 112.5
15 4 2 13 34.5 30.9 2.0 45
15 4 2 14 38.2 19.7 1.4 48
15 4 2 15 36.7 15.6 2.3 231
15 4 2 16 36.3 19.9 0.8 43
15 4 2 17 36.0 26.6 2.6 90
15 4 2 18 35.0 26.1 1.6 292.5
15 4 2 19 34.9 30.7 1.2 22.5
15 4 2 20 33.1 33.9 2.1 225
15 4 2 21 26.1 35.1 0.7 337.5
15 4 2 22 25.3 36.7 1.5 90
15 4 2 23 26.6 39.1 0.0 337.5
15 4 2 24 26.1 28.6 1.2 270
15 4 3 1 28.6 20.9 1.3 270
15 4 3 2 28.1 21.1 0.3 157.5
15 4 3 3 28.6 23.3 0.0 135
15 4 3 4 27.6 20.9 1.2 292.5
15 4 3 5 27.9 18.8 0.0 22.5
15 4 3 6 27.6 19.7 1.7 315
15 4 3 7 28.0 18.8 2.3 45.3
15 4 3 8 29.1 15.3 2.3 225
15 4 3 9 29.4 14.6 1.2 270
15 4 3 10 30.6 13.7 1.3 90
15 4 3 11 31.6 15.3 1.5 48.2
15 4 3 12 32.8 14.1 2.3 45.9
15 4 3 13 35.9 19.7 2.1 225
15 4 3 14 39.4 16.0 1.9 220.3
15 4 3 15 40.2 15.5 1.3 360
15 4 3 16 36.3 13.0 1.9 360
15 4 3 17 33.2 12.7 1.0 360
15 4 3 18 30.3 16.9 0.7 360
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 3 19 28.9 19.7 0.0 360
15 4 3 20 27.6 20.9 0.4 45
15 4 3 21 26.8 19.2 1.3 218.4
15 4 3 22 24.3 17.6 3.2 225
15 4 3 23 23.1 19.9 0.0 157.5
15 4 3 24 22.1 16.6 1.2 312.5
15 4 4 1 21.3 25.6 1.2 292.5
15 4 4 2 23.6 33.4 2.1 292.5
15 4 4 3 22.1 40.6 2.1 247.5
15 4 4 4 22.7 45.9 2.6 157.5
15 4 4 5 22.4 52.4 1.5 292.5
15 4 4 6 23.1 48.8 1.3 272
15 4 4 7 24.6 42.2 0.0 337.5
15 4 4 8 25.9 37.7 1.3 270
15 4 4 9 26.1 29.1 2.1 225
15 4 4 10 27.8 28.1 1.5 275
15 4 4 11 28.3 26.4 0.0 360
15 4 4 12 32.4 25.3 0.0 292.5
15 4 4 13 35.5 27.1 2.5 268
15 4 4 14 38.9 30.9 3.6 274
15 4 4 15 39.8 28.6 3.1 270
15 4 4 16 37.5 24.6 2.5 272
15 4 4 17 34.3 23.8 1.6 276
15 4 4 18 31.2 43.9 0.0 360
15 4 4 19 29.4 44.8 0.0 337.5
15 4 4 20 26.5 42.1 0.0 45
15 4 4 21 25.1 40.6 3.7 270
15 4 4 22 24.6 39.1 0.6 312.5
15 4 4 23 23.6 38.9 1.1 312.5
15 4 4 24 23.4 37.4 0.7 292.5
15 4 5 1 24.6 36.1 1.3 225
15 4 5 2 24.3 40.8 1.2 312.5
15 4 5 3 24.9 43.6 0.0 45
15 4 5 4 23.6 48.7 0.0 157.5
15 4 5 5 23.8 52.2 1.3 312.5
15 4 5 6 24.6 39.4 0.6 247.5
15 4 5 7 25.6 42.1 0.5 270
15 4 5 8 26.1 32.8 0.0 45
15 4 5 9 27.3 33.6 0.7 270
15 4 5 10 27.6 35.1 0.0 292.5
15 4 5 11 30.2 37.9 0.5 312.5
15 4 5 12 33.4 38.1 1.2 312.5
15 4 5 13 36.3 31.0 1.1 157.5
15 4 5 14 38.9 25.1 0.3 312.5
15 4 5 15 40.2 23.2 1.6 67.5
15 4 5 16 37.3 15.6 1.3 67.5
15 4 5 17 35.7 26.6 2.5 220.3
15 4 5 18 33.2 29.7 1.6 315
15 4 5 19 31.8 30.2 0.0 337.5
15 4 5 20 30.3 42.9 0.0 337.5
15 4 5 21 25.0 40.6 0.5 135
15 4 5 22 24.6 39.1 1.3 157.5
15 4 5 23 25.6 35.1 0.7 292.5
15 4 5 24 26.1 33.0 1.5 315
Page 375
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 6 1 25.1 39.4 0.7 270
15 4 6 2 25.9 60.9 1.3 312.5
15 4 6 3 25.1 59.7 1.5 157.5
15 4 6 4 25.6 70.6 2.1 360
15 4 6 5 24.3 65.1 0.5 315
15 4 6 6 25.6 62.0 1.6 270
15 4 6 7 26.9 52.1 4.2 225
15 4 6 8 27.3 34.9 1.1 292.5
15 4 6 9 28.1 35.1 0.7 247.5
15 4 6 10 29.6 39.1 0.6 312.5
15 4 6 11 30.3 38.6 0.6 135
15 4 6 12 34.5 39.0 2.4 225
15 4 6 13 37.9 33.1 1.4 135
15 4 6 14 40.7 29.7 0.6 67.5
15 4 6 15 39.6 26.4 2.4 112.5
15 4 6 16 36.5 22.7 2.3 157.5
15 4 6 17 34.3 25.9 1.6 270
15 4 6 18 30.6 30.9 0.9 112.5
15 4 6 19 29.2 33.0 2.3 270
15 4 6 20 28.1 39.9 1.3 265
15 4 6 21 27.6 43.7 1.9 270
15 4 6 22 25.6 40.9 2.1 270
15 4 6 23 24.6 38.2 2.3 90
15 4 6 24 24.9 37.9 0.0 135
15 4 7 1 25.3 33.0 0.0 67.5
15 4 7 2 23.6 30.6 1.3 270
15 4 7 3 22.1 39.4 1.2 225
15 4 7 4 23.6 42.9 0.0 45
15 4 7 5 23.5 49.1 0.7 270
15 4 7 6 24.6 56.2 0.0 157.5
15 4 7 7 25.6 52.1 1.2 157.5
15 4 7 8 26.3 49.6 1.5 315
15 4 7 9 26.4 39.7 3.6 225
15 4 7 10 28.9 31.9 1.9 225
15 4 7 11 29.3 33.5 0.0 67.5
15 4 7 12 32.4 34.8 1.6 226
15 4 7 13 34.5 37.9 1.2 135
15 4 7 14 38.2 30.9 0.4 157.5
15 4 7 15 40.3 29.7 1.4 312.5
15 4 7 16 37.5 23.4 1.1 360
15 4 7 17 35.4 21.0 1.3 90
15 4 7 18 33.2 28.1 2.3 112.5
15 4 7 19 31.2 32.9 0.0 270
15 4 7 20 28.4 36.7 0.0 135
15 4 7 21 26.6 40.9 0.4 112.5
15 4 7 22 25.4 43.1 3.2 215
15 4 7 23 25.6 49.6 0.7 90
15 4 7 24 24.6 48.6 1.2 157.5
15 4 8 1 24.5 33.0 2.3 67.5
15 4 8 2 24.3 30.6 1.6 225
15 4 8 3 24.9 39.4 1.3 57.3
15 4 8 4 23.1 42.9 2.6 45
15 4 8 5 23.6 54.7 2.8 45
15 4 8 6 24.9 49.2 2.1 45
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 8 7 25.6 52.1 2.1 45
15 4 8 8 26.1 49.6 0.4 292.5
15 4 8 9 27.2 39.7 0.7 22.5
15 4 8 10 28.6 31.9 1.5 360
15 4 8 11 29.1 33.5 2.1 135
15 4 8 12 32.5 34.8 0.7 270
15 4 8 13 34.8 37.9 1.8 312.5
15 4 8 14 38.5 30.9 1.7 270
15 4 8 15 39.7 29.7 2.5 225
15 4 8 16 37.4 23.4 2.7 315
15 4 8 17 33.5 21.0 1.8 315
15 4 8 18 30.2 28.1 1.1 270
15 4 8 19 28.9 32.9 0.0 67.5
15 4 8 20 27.2 36.7 0.0 90
15 4 8 21 25.6 40.9 0.7 135
15 4 8 22 24.3 43.1 1.9 270
15 4 8 23 26.3 49.6 2.8 270
15 4 8 24 25.6 48.6 1.2 292.5
15 4 9 1 24.3 39.1 1.5 230
15 4 9 2 23.1 37.5 2.3 225
15 4 9 3 23.0 36.8 3.2 215
15 4 9 4 22.8 45.9 1.2 220
15 4 9 5 22.5 33.2 2.3 230
15 4 9 6 22.3 39.4 1.6 225
15 4 9 7 24.6 40.6 1.6 270
15 4 9 8 26.4 41.8 2.5 270
15 4 9 9 27.2 42.7 1.3 225
15 4 9 10 28.5 40.2 0.0 112.5
15 4 9 11 29.4 33.2 0.0 270
15 4 9 12 30.2 30.9 0.8 247.5
15 4 9 13 32.5 26.4 0.6 270
15 4 9 14 35.3 22.1 3.5 43.5
15 4 9 15 35.1 19.7 0.0 337.5
15 4 9 16 34.8 14.6 2.1 315
15 4 9 17 34.6 12.9 1.4 360
15 4 9 18 33.2 20.0 2.1 360
15 4 9 19 30.6 26.6 0.0 22.5
15 4 9 20 29.1 31.9 1.2 135
15 4 9 21 27.6 33.7 0.0 292.5
15 4 9 22 26.0 39.1 0.0 45
15 4 9 23 25.6 40.9 1.2 312.5
15 4 9 24 25.1 43.3 1.6 270
15 4 10 1 24.0 39.1 1.8 312.5
15 4 10 2 23.6 37.5 1.2 157.5
15 4 10 3 22.1 36.8 0.0 157.5
15 4 10 4 22.6 44.1 0.0 90
15 4 10 5 21.3 33.2 1.3 67.5
15 4 10 6 22.6 39.4 1.5 157.5
15 4 10 7 23.4 40.6 0.6 90
15 4 10 8 24.9 41.8 0.0 22.5
15 4 10 9 25.1 42.7 1.6 292.5
15 4 10 10 26.8 40.2 0.0 135
15 4 10 11 28.9 33.2 0.0 157.5
15 4 10 12 30.6 30.9 1.7 90
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 10 13 31.6 26.4 1.6 45
15 4 10 14 35.3 22.1 1.1 270
15 4 10 15 37.8 19.7 1.5 185
15 4 10 16 37.2 14.6 1.0 187.3
15 4 10 17 36.1 12.9 2.0 270.2
15 4 10 18 34.6 20.0 0.8 270
15 4 10 19 30.6 26.6 2.2 45.1
15 4 10 20 29.5 31.9 2.2 90
15 4 10 21 28.1 33.7 3.2 225
15 4 10 22 27.6 39.1 1.7 230
15 4 10 23 26.1 40.9 1.5 238
15 4 10 24 25.2 43.3 0.7 230
15 4 11 1 23.6 46.1 2.1 225
15 4 11 2 24.0 48.3 0.7 230
15 4 11 3 23.6 49.1 0.6 225
15 4 11 4 23.2 50.6 2.3 270
15 4 11 5 22.6 53.3 0.0 43.2
15 4 11 6 24.6 50.9 1.3 292.5
15 4 11 7 25.6 49.7 3.2 225
15 4 11 8 26.8 45.1 2.9 270
15 4 11 9 28.9 39.1 0.3 90
15 4 11 10 29.1 33.2 1.6 45
15 4 11 11 30.6 32.9 1.5 225
15 4 11 12 31.6 39.1 0.9 90
15 4 11 13 34.1 41.1 0.9 135
15 4 11 14 36.5 39.4 0.6 157.5
15 4 11 15 38.4 29.7 2.1 270
15 4 11 16 36.9 27.1 1.8 270
15 4 11 17 34.8 22.6 1.8 247.5
15 4 11 18 31.2 30.9 0.0 45
15 4 11 19 29.4 33.1 0.0 360
15 4 11 20 27.6 39.1 0.0 45
15 4 11 21 26.2 42.6 1.1 45
15 4 11 22 25.6 49.7 1.1 157.5
15 4 11 23 24.3 50.3 1.2 315
15 4 11 24 23.6 53.3 0.0 157.5
15 4 12 1 24.6 56.9 1.3 312.5
15 4 12 2 23.6 59.1 0.0 315
15 4 12 3 22.3 60.6 0.7 315
15 4 12 4 22.6 66.6 0.0 360
15 4 12 5 21.6 68.9 0.0 22.5
15 4 12 6 21.8 60.9 1.3 220
15 4 12 7 25.6 53.1 2.6 315
15 4 12 8 26.1 49.2 0.0 337.5
15 4 12 9 27.6 43.1 1.6 247.5
15 4 12 10 28.9 40.6 0.0 337.5
15 4 12 11 29.6 36.0 0.0 90
15 4 12 12 29.1 38.1 0.9 90
15 4 12 13 30.6 39.6 1.7 90
15 4 12 14 28.6 39.1 2.0 312.5
15 4 12 15 29.1 30.9 0.7 157.5
15 4 12 16 27.6 27.3 0.0 22.5
15 4 12 17 25.6 47.8 1.2 45
15 4 12 18 26.1 55.9 0.0 360
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 12 19 28.6 41.6 0.0 90
15 4 12 20 26.5 41.6 1.6 223.5
15 4 12 21 25.6 38.9 0.6 135
15 4 12 22 24.3 37.1 0.3 45
15 4 12 23 23.0 36.0 0.6 67.5
15 4 12 24 22.3 35.9 0.0 90
15 4 13 1 23.6 46.6 1.6 312.5
15 4 13 2 22.3 52.3 1.6 315.4
15 4 13 3 22.0 59.1 0.0 315
15 4 13 4 21.0 63.8 2.3 225
15 4 13 5 20.3 71.6 1.7 270
15 4 13 6 21.6 65.3 1.2 312.5
15 4 13 7 22.3 66.1 0.5 225
15 4 13 8 23.4 50.1 0.6 157.5
15 4 13 9 24.6 53.1 0.5 112.5
15 4 13 10 25.9 52.9 1.6 225
15 4 13 11 28.3 49.9 0.0 157.5
15 4 13 12 32.6 47.1 0.5 90
15 4 13 13 38.5 42.1 1.3 312.5
15 4 13 14 39.3 38.7 2.3 43.2
15 4 13 15 37.5 33.1 1.4 112.5
15 4 13 16 37.2 32.9 1.0 157.5
15 4 13 17 35.4 39.1 0.4 56.2
15 4 13 18 33.6 40.3 1.5 67.5
15 4 13 19 31.2 39.1 1.0 67.5
15 4 13 20 29.4 50.6 0.0 22.5
15 4 13 21 28.6 53.1 0.0 67.5
15 4 13 22 27.3 59.7 0.0 247.5
15 4 13 23 26.4 60.9 0.0 270
15 4 13 24 25.7 63.2 0.0 292.5
15 4 14 1 25.2 69.1 1.2 225
15 4 14 2 24.8 70.6 0.6 270
15 4 14 3 24.2 79.1 1.9 46.3
15 4 14 4 24.0 81.6 2.1 270
15 4 14 5 23.6 75.9 0.0 225
15 4 14 6 23.8 66.1 0.0 360
15 4 14 7 24.2 61.9 0.0 315
15 4 14 8 28.5 53.1 0.0 312.5
15 4 14 9 29.4 50.9 0.0 90
15 4 14 10 30.1 49.1 0.4 22.5
15 4 14 11 31.3 36.1 0.0 135
15 4 14 12 33.6 32.1 2.0 45
15 4 14 13 35.4 30.9 1.8 52.5
15 4 14 14 38.9 29.1 1.3 135
15 4 14 15 39.8 33.1 1.4 53.6
15 4 14 16 37.4 39.1 1.4 315
15 4 14 17 35.2 49.8 2.0 315
15 4 14 18 32.6 50.6 1.1 360
15 4 14 19 30.1 51 0.3 222.3
15 4 14 20 29.5 49.3 0.0 67.5
15 4 14 21 28.3 46.8 0.0 90
15 4 14 22 27.4 43.1 1.4 270
15 4 14 23 27.3 40.6 0.0 135
15 4 14 24 26.2 38.6 2.6 312.5
Page 376
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 15 1 35.7 56.9 0.7 312.5
15 4 15 2 35.2 59.1 0.0 292.5
15 4 15 3 32.6 60.6 0.0 315
15 4 15 4 31.5 66.6 0.5 312.5
15 4 15 5 30.6 63.2 0.3 270
15 4 15 6 29.8 60.9 0.6 157.5
15 4 15 7 30.2 53.1 2.3 223.5
15 4 15 8 31.5 49.2 2.6 230.5
15 4 15 9 31.9 43.1 0.0 90
15 4 15 10 32.4 40.6 1.3 53.2
15 4 15 11 33.5 36.0 0.4 135
15 4 15 12 35.6 38.1 2.3 225
15 4 15 13 37.3 39.6 0.6 247.5
15 4 15 14 39.4 39.1 3.2 270
15 4 15 15 40.2 30.9 1.4 292.5
15 4 15 16 40.8 25.7 1.7 312.5
15 4 15 17 38.4 47.8 1.2 270
15 4 15 18 36.2 55.9 2.3 52.8
15 4 15 19 34.3 41.6 1.2 53.4
15 4 15 20 31.2 41.6 0.0 90
15 4 15 21 31.0 38.9 1.6 247.5
15 4 15 22 30.7 37.1 0.4 292.5
15 4 15 23 30.4 36.0 0.0 315
15 4 15 24 29.6 35.9 0.0 46.3
15 4 16 1 29.1 39.6 1.2 270
15 4 16 2 31.9 40.6 0.5 45.6
15 4 16 3 31.6 43.9 0.6 90
15 4 16 4 31.0 54.9 2.1 316
15 4 16 5 31.2 52.6 0.0 337.5
15 4 16 6 32.6 32.8 0.0 90
15 4 16 7 33.2 33.9 0.0 22.5
15 4 16 8 33.6 34.8 0.0 256
15 4 16 9 36.6 35.6 0.0 360
15 4 16 10 39.6 36.1 0.0 183
15 4 16 11 41.6 35 0.3 49
15 4 16 12 42.9 33.9 0.7 53.2
15 4 16 13 43.4 32.1 2.3 43.1
15 4 16 14 43.0 20.9 0.4 46.6
15 4 16 15 40.3 17.3 0.0 67.5
15 4 16 16 39.5 18.6 1.3 312.5
15 4 16 17 38.2 38.9 1.0 112.5
15 4 16 18 37.6 39.1 0.6 312.5
15 4 16 19 35.6 40.6 0.0 157.5
15 4 16 20 36.0 38.8 3.2 270
15 4 16 21 32.0 36.1 1.2 225
15 4 16 22 32.6 35.9 0.0 315
15 4 16 23 32.1 33.2 0.0 360
15 4 16 24 32.9 32.9 0.6 312.5
15 4 17 1 32.8 40.3 0.5 247.5
15 4 17 2 28.9 42.6 0.6 247.5
15 4 17 3 28.4 46.9 0.0 186.4
15 4 17 4 28.1 49.1 1.6 224.5
15 4 17 5 28.0 52.3 0.0 175.3
15 4 17 6 29.3 55.9 0.0 112.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 17 7 30.6 49.6 0.0 112.5
15 4 17 8 32.6 32.4 1.3 225.3
15 4 17 9 33.5 30.9 0.0 360
15 4 17 10 35.6 38.9 0.0 360
15 4 17 11 37.1 40.6 1.0 245.2
15 4 17 12 39.0 30.9 0.0 45
15 4 17 13 41.9 29.1 1.3 337.5
15 4 17 14 43.6 20.6 2.4 360
15 4 17 15 40.6 12.6 1.5 22.5
15 4 17 16 39.1 29.1 1.7 90
15 4 17 17 39.1 31.9 2.4 360
15 4 17 18 38.1 36.7 0.8 270
15 4 17 19 37.1 42.9 1.6 270
15 4 17 20 36.8 49.6 1.3 270
15 4 17 21 35.2 46.2 0.0 337.5
15 4 17 22 33.2 45.2 2.3 270
15 4 17 23 32.6 43.2 0.0 157.5
15 4 17 24 32.6 41.9 1.3 135
15 4 18 1 30.6 40.6 0.0 157.5
15 4 18 2 28.9 39.1 1.7 315
15 4 18 3 28.4 38.1 0.0 185
15 4 18 4 27.6 37.9 1.3 229.5
15 4 18 5 26.3 32.6 0.0 135
15 4 18 6 27.9 33.7 0.0 179.2
15 4 18 7 28.6 36.1 0.0 360
15 4 18 8 30.6 37.9 0.7 360
15 4 18 9 33.6 39.8 0.5 315
15 4 18 10 35.9 29.1 1.5 320
15 4 18 11 37.1 22.6 0.7 321
15 4 18 12 39.0 20.7 1.2 315
15 4 18 13 41.9 18.9 2.3 316
15 4 18 14 43.6 13.2 1.1 67.5
15 4 18 15 40.1 10.6 3.0 67.5
15 4 18 16 38.3 6.7 2.8 247.5
15 4 18 17 37.1 16.7 1.1 247.5
15 4 18 18 36.2 19.2 0.6 270
15 4 18 19 37.1 33.5 0.5 225
15 4 18 20 36.8 29.1 0.6 225
15 4 18 21 35.2 25.4 1.2 225
15 4 18 22 26.9 26.1 0.6 270
15 4 18 23 27.1 26.9 0.2 270
15 4 18 24 28.0 25.1 0.0 315
15 4 19 1 28.1 23.1 0.0 315
15 4 19 2 28.6 20.9 2.3 225
15 4 19 3 28.1 19.5 1.5 135
15 4 19 4 27.6 18.4 0.0 157.5
15 4 19 5 27.3 17.6 0.6 90
15 4 19 6 28.0 15.3 0.0 135
15 4 19 7 29.1 14.2 1.7 225
15 4 19 8 30.6 13.2 0.0 90
15 4 19 9 34.6 11.9 0.3 135
15 4 19 10 36.6 10.9 0.0 67.5
15 4 19 11 37.1 9.8 0.3 360
15 4 19 12 39.6 8.6 0.0 45
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 19 13 40.1 7.2 1.4 22.5
15 4 19 14 41.1 8.3 0.4 360
15 4 19 15 40.6 8.4 0.0 360
15 4 19 16 38.6 9.6 0.7 270
15 4 19 17 36.1 15.6 1.0 312.5
15 4 19 18 35.6 19.7 0.3 292.5
15 4 19 19 34.6 20.2 0.6 247.5
15 4 19 20 33.2 21.9 2.3 360
15 4 19 21 32.6 23.6 0.5 315
15 4 19 22 30.6 25.9 0.9 270
15 4 19 23 33.1 26.7 2.1 315
15 4 19 24 33.6 30.9 0.6 247.5
15 4 20 1 30.3 36.6 1.3 225
15 4 20 2 29.3 30.6 0.0 337.5
15 4 20 3 29.9 29.4 1.6 215
15 4 20 4 28.1 16.4 1.2 220.3
15 4 20 5 28.3 15.1 1.6 226.1
15 4 20 6 29.6 14.6 0.8 230.2
15 4 20 7 30.6 13.9 2.3 90
15 4 20 8 29.1 15.6 0.0 45
15 4 20 9 31.6 15.3 0.0 45
15 4 20 10 34.6 14.3 0.8 360
15 4 20 11 36.0 13.2 2.2 360
15 4 20 12 39.9 10.9 1.8 360
15 4 20 13 40.2 14.4 0.4 360
15 4 20 14 40.6 10.6 0.0 45
15 4 20 15 38.1 5.4 0.9 90
15 4 20 16 39.2 11.1 0.7 225
15 4 20 17 38.6 12.9 2.3 225
15 4 20 18 37.6 13.3 0.0 312.5
15 4 20 19 36.2 15.6 0.0 157.5
15 4 20 20 38.1 12.3 0.7 157.5
15 4 20 21 37.6 14.6 0.8 312.5
15 4 20 22 36.2 15.3 0.5 231.2
15 4 20 23 35.3 13.2 0.9 225
15 4 20 24 34.1 15.6 1.3 215.6
15 4 21 1 33.6 16.9 1.2 216.4
15 4 21 2 30.3 19.5 0.7 220.3
15 4 21 3 28.1 23.6 0.6 272.4
15 4 21 4 26.9 26.6 0.0 22.5
15 4 21 5 26.4 23.1 2.1 270
15 4 21 6 26.0 22.8 1.2 316.4
15 4 21 7 27.9 20.9 0.8 320
15 4 21 8 28.6 19.7 0.6 312.3
15 4 21 9 31.0 16.3 1.6 225
15 4 21 10 33.6 14.2 0.0 184.2
15 4 21 11 36.6 15.6 1.5 360
15 4 21 12 38.0 16.9 0.9 182.4
15 4 21 13 41.9 19.1 1.8 45
15 4 21 14 41.3 18.6 2.0 22.5
15 4 21 15 40.2 15.2 1.0 360
15 4 21 16 39.2 14.3 0.0 312.5
15 4 21 17 38.1 11.7 2.2 225
15 4 21 18 37.6 12.9 0.7 225
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 21 19 36.5 15.6 0.0 312.5
15 4 21 20 37.6 19.4 2.1 225
15 4 21 21 38.6 19 1.9 225
15 4 21 22 37.6 22.9 1.1 225
15 4 21 23 36.2 25.6 0.6 225
15 4 21 24 35.3 29.1 0.0 360
15 4 22 1 34.1 21.3 0.0 360
15 4 22 2 30.6 22.6 0.0 337.5
15 4 22 3 30.5 24.6 0.7 45
15 4 22 4 29.0 23.1 0.0 156.3
15 4 22 5 28.3 20.9 0.0 165.4
15 4 22 6 31.2 19.4 1.3 270
15 4 22 7 33.2 18.4 0.3 270
15 4 22 8 34.6 16.5 0.0 315
15 4 22 9 35.6 18.7 0.0 315
15 4 22 10 36.1 15.6 0.0 320
15 4 22 11 37.3 14.3 2.3 315
15 4 22 12 38.6 11.3 2.0 318.5
15 4 22 13 39.1 10.6 1.4 45
15 4 22 14 40.6 11.9 2.5 186.2
15 4 22 15 39.2 10.9 1.1 360
15 4 22 16 39.1 7.4 0.9 312.5
15 4 22 17 38.6 11.6 2.0 312.5
15 4 22 18 37.6 13.5 0.0 270
15 4 22 19 38.6 15.7 0.0 292.5
15 4 22 20 36.1 19.4 0.0 157.5
15 4 22 21 35.1 20.3 1.2 360
15 4 22 22 34.6 22.6 0.7 247.5
15 4 22 23 33.0 24.6 0.0 360
15 4 22 24 32.1 22.1 0.0 22.5
15 4 23 1 31.3 24.6 0.6 360
15 4 23 2 34.1 23.1 0.0 22.5
15 4 23 3 30.6 27.9 0.0 360
15 4 23 4 29.4 28.1 0.0 315
15 4 23 5 28.0 30.9 0.0 320
15 4 23 6 30.1 23.5 0.0 333
15 4 23 7 31.2 20.9 0.0 360
15 4 23 8 33.2 18.4 3.2 312.3
15 4 23 9 34.6 22.9 2.1 315.5
15 4 23 10 36.6 19.4 1.5 320.2
15 4 23 11 39.1 17.6 0.8 225.1
15 4 23 12 41.0 16.5 0.0 220
15 4 23 13 41.5 12.6 0.0 360
15 4 23 14 40.9 13.4 1.6 312.6
15 4 23 15 39.1 10.6 0.0 360
15 4 23 16 37.3 7.2 1.4 315
15 4 23 17 37.3 5.1 0.3 270
15 4 23 18 36.9 12.6 0.0 360
15 4 23 19 35.2 14.9 0.0 337.5
15 4 23 20 35.6 16.7 0.0 225
15 4 23 21 34.1 19.2 0.0 225
15 4 23 22 35.1 20.7 1.3 315
15 4 23 23 34.6 23.6 1.3 315
15 4 23 24 33.0 25.4 0.0 337.5
Page 377
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 24 1 32.1 24.1 1.7 315
15 4 24 2 32.9 22.6 0.0 337.5
15 4 24 3 32.6 25.9 0.0 337.5
15 4 24 4 31.6 26.1 0.0 112.5
15 4 24 5 31.0 26.8 0.0 307.4
15 4 24 6 29.6 24.3 0.4 320.1
15 4 24 7 28.1 26.7 1.3 316.4
15 4 24 8 29.3 21.2 0.0 360
15 4 24 9 32.6 20.9 0.0 174.2
15 4 24 10 34.4 19.7 0.0 270
15 4 24 11 36.6 18.6 0.0 45
15 4 24 12 38.1 17.3 0.0 90
15 4 24 13 40.6 15.9 2.5 22.5
15 4 24 14 43.2 16.7 0.7 45
15 4 24 15 44.1 10.9 0.5 270
15 4 24 16 40.3 9.4 0.7 315
15 4 24 17 39.4 8.3 1.2 312.5
15 4 24 18 38.2 10.7 1.6 270
15 4 24 19 39.4 19.3 1.2 312.5
15 4 24 20 37.6 20.9 1.7 225
15 4 24 21 35.1 21.6 0.0 45.6
15 4 24 22 34.1 27.6 1.6 221.2
15 4 24 23 33.1 22.6 1.2 225
15 4 24 24 32.6 25.6 0.0 42.3
15 4 25 1 31.6 28.6 0.0 225
15 4 25 2 30.3 30.6 0.0 43.2
15 4 25 3 29.6 31.6 0.0 225
15 4 25 4 27.6 33.5 0.0 112.5
15 4 25 5 27.6 35.9 0.0 90
15 4 25 6 28.6 29.4 0.0 67.5
15 4 25 7 29.2 28.1 0.0 90
15 4 25 8 30.6 22.6 1.3 67.5
15 4 25 9 31.6 25.9 0.8 90
15 4 25 10 32.6 20 0.0 90
15 4 25 11 33.6 19.4 0.0 360
15 4 25 12 34.1 18.3 0.0 67.5
15 4 25 13 35.6 16.2 1.6 270.5
15 4 25 14 41.3 11.6 0.7 90
15 4 25 15 40.3 10.6 1.6 67.5
15 4 25 16 38.0 9.5 0.5 270
15 4 25 17 37.2 5.1 1.1 360
15 4 25 18 39.6 10.6 1.0 360
15 4 25 19 39.4 12.6 0.9 270
15 4 25 20 37.6 13.7 1.2 247.5
15 4 25 21 35.1 16.4 1.6 247.5
15 4 25 22 34.1 19.2 2.3 312.5
15 4 25 23 33.1 20.9 1.2 225
15 4 25 24 30.1 22.4 1.6 270
15 4 26 1 31.6 23.4 1.8 270
15 4 26 2 31.0 25.6 0.0 292.5
15 4 26 3 31.9 24.1 0.0 360
15 4 26 4 31.0 25.6 0.0 67.5
15 4 26 5 32.6 20.6 0.0 45
15 4 26 6 33.5 19.7 3.3 316.4
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 26 7 32.6 18.4 0.0 185
15 4 26 8 31.2 16.2 0.0 173
15 4 26 9 32.6 15.3 0.0 225.5
15 4 26 10 33.4 13.7 0.0 156
15 4 26 11 38.9 10.9 0.9 125.5
15 4 26 12 39.1 19.5 0.0 360
15 4 26 13 40.6 12.7 1.6 22.5
15 4 26 14 43.9 16.5 1.0 360
15 4 26 15 39.2 10.9 1.2 270
15 4 26 16 37.6 6.7 0.8 270
15 4 26 17 38.1 8.3 0.0 125.8
15 4 26 18 37.6 10.9 0.0 312.5
15 4 26 19 36.2 13.6 3.3 337.5
15 4 26 20 35.1 14.9 0.0 312.5
15 4 26 21 33.2 15.7 1.2 315
15 4 26 22 32.6 16.8 0.0 337.5
15 4 26 23 31.6 19.2 1.6 225
15 4 26 24 32.6 20.9 1.2 231.4
15 4 27 1 31.6 23.6 2.5 312.5
15 4 27 2 30.3 25.7 2.8 310.2
15 4 27 3 29.6 26.9 3.1 308.7
15 4 27 4 28.6 28.1 0.0 22.5
15 4 27 5 28.0 32.4 0.0 135
15 4 27 6 29.6 30.9 1.3 210.5
15 4 27 7 30.9 29.8 0.0 337.5
15 4 27 8 31.6 29 0.0 127.5
15 4 27 9 33.6 25.1 0.0 135
15 4 27 10 35.6 20.9 1.4 315.5
15 4 27 11 37.6 19.7 1.8 360
15 4 27 12 39.1 21.4 2.4 360
15 4 27 13 42.6 15.3 0.7 22.5
15 4 27 14 44.2 12.5 0.6 112.5
15 4 27 15 41.3 9.3 0.0 157.5
15 4 27 16 40.3 8.2 0.7 270
15 4 27 17 38.6 5.7 1.2 225
15 4 27 18 39.6 9.9 0.5 312.5
15 4 27 19 39.4 12.6 1.6 270
15 4 27 20 37.6 13.7 0.0 225
15 4 27 21 35.1 15.6 0.0 270
15 4 27 22 34.1 19.2 0.0 360
15 4 27 23 33.1 21.3 0.0 360
15 4 27 24 30.1 25.6 0.0 315
15 4 28 1 31.6 26.7 0.0 312.5
15 4 28 2 30.6 29.1 0.0 312.5
15 4 28 3 29.5 30.1 0.7 312.5
15 4 28 4 27.6. 31.9 1.2 312.5
15 4 28 5 28.6 32.6 0.0 67.5
15 4 28 6 29.6 30.9 0.0 112.5
15 4 28 7 30.6 29.7 0.0 45
15 4 28 8 31.6 28.6 0.0 360
15 4 28 9 32.6 25.1 3.3 316.2
15 4 28 10 33.6 22 0.0 45
15 4 28 11 32.1 20.9 0.6 320.7
15 4 28 12 35.6 19.7 1.0 112.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 28 13 37.4 15.6 1.3 67.5
15 4 28 14 40.9 14.3 1.1 112.5
15 4 28 15 41.1 12.9 2.6 112.5
15 4 28 16 38.6 10.9 1.6 157.5
15 4 28 17 37.1 7.2 1.0 247.5
15 4 28 18 36.2 9.4 0.6 312.5
15 4 28 19 35.9 7.6 0.0 247.5
15 4 28 20 30.6 10.6 0.0 292.5
15 4 28 21 32.6 12.3 0.0 337.5
15 4 28 22 33.2 15.6 0.0 22.5
15 4 28 23 30.6 16.7 1.2 247.5
15 4 28 24 29.6 19 1.3 270
15 4 29 1 28.6 20.6 0.0 225
15 4 29 2 26.5 23.4 0.0 43.2
15 4 29 3 25.6 25.9 1.5 270
15 4 29 4 23.2 26.7 0.3 90
15 4 29 5 23.9 34.3 0.0 22.5
15 4 29 6 24.6 33.7 0.0 112.5
15 4 29 7 25.9 31.9 0.0 312.5
15 4 29 8 26.1 32.6 0.0 360
15 4 29 9 28.6 30.9 0.0 315
15 4 29 10 30.7 29.1 1.2 270
15 4 29 11 32.6 27.6 1.6 315
15 4 29 12 37.2 23 0.0 337.5
15 4 29 13 40.6 22 1.9 90
15 4 29 14 42.9 19.8 0.0 312.5
15 4 29 15 39.6 17.6 2.1 312.5
15 4 29 16 37.6 15.5 2.3 157.5
15 4 29 17 36.6 13.2 0.0 312.5
15 4 29 18 36.1 7.1 0.6 292.5
15 4 29 19 35.3 13.7 0.0 135
15 4 29 20 35.5 19.2 0.0 45
15 4 29 21 35.1 20.9 0.0 312.5
15 4 29 22 34.3 22.9 0.7 312.5
15 4 29 23 33.9 26.4 0.0 312.5
15 4 29 24 32.6 28.7 0.0 53.1
15 4 30 1 32.8 29.3 0.0 270
15 4 30 2 30.3 30.9 0.0 183
15 4 30 3 29.5 31.6 3.3 225
15 4 30 4 28.6 32.8 1.0 22.5
15 4 30 5 28.6 39.4 1.2 225
15 4 30 6 29.3 33.2 3.3 292.5
15 4 30 7 29.9 29.4 1.5 247.5
15 4 30 8 30.6 25.6 0.7 270
15 4 30 9 31.6 23.1 0.0 292.5
15 4 30 10 31.9 22 1.3 22.5
15 4 30 11 32.6 19.5 2.4 315
15 4 30 12 35.7 18.3 2.3 22.5
15 4 30 13 38.6 17.74 1.2 67.5
15 4 30 14 40.9 18.6 1.4 90
15 4 30 15 41.6 16.9 3.4 312.5
15 4 30 16 40.6 18.9 1.8 312.5
15 4 30 17 39.6 19.6 0.0 90
15 4 30 18 38.1 20.7 0.0 22.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 4 30 19 37.6 21.8 0.0 157.5
15 4 30 20 36.2 22.6 1.2 270
15 4 30 21 35.9 23.6 0.0 135
15 4 30 22 34.6 25.9 0.0 22.5
15 4 30 23 33.5 26.1 1.2 312.5
15 4 30 24 32.6 29 0.0 337.5
15 5 1 1 30.6 29.3 1.6 312.5
15 5 1 2 28.6 30.9 0.0 157.5
15 5 1 3 26.5 31.6 0.0 157.5
15 5 1 4 25.6 30.6 0.0 135
15 5 1 5 24.0 29.4 0.0 56.2
15 5 1 6 25.6 23.1 0.0 90
15 5 1 7 26.9 29.4 1.5 270
15 5 1 8 28.6 25.6 0.0 90
15 5 1 9 31.6 23.1 1.6 247.5
15 5 1 10 33.4 22 1.2 312.5
15 5 1 11 36.6 19.5 0.0 270
15 5 1 12 34.6 18.3 1.2 360
15 5 1 13 38.6 17.74 0.4 337.5
15 5 1 14 41.5 18.6 0.0 112.5
15 5 1 15 40.6 16.9 0.0 90
15 5 1 16 38.2 7.6 0.0 112.5
15 5 1 17 39.0 19.6 1.2 312.5
15 5 1 18 38.6 20.7 0.0 315
15 5 1 19 37.6 21.8 0.0 247.5
15 5 1 20 36.5 22.6 0.7 225
15 5 1 21 35.6 23.6 1.3 312.5
15 5 1 22 34.6 25.9 0.1 270
15 5 1 23 33.5 26.1 0.2 270
15 5 1 24 32.6 29 0.0 90
15 5 2 1 30.4 20.1 0.0 112.5
15 5 2 2 28.6 19.6 0.0 135
15 5 2 3 26.5 13.5 0.0 135
15 5 2 4 24.3 22.1 0.0 112.5
15 5 2 5 23.6 20.9 0.0 112.5
15 5 2 6 25.6 19.5 1.2 225
15 5 2 7 25.9 18.2 0.0 157.5
15 5 2 8 26.4 16.3 1.4 225
15 5 2 9 27.9 14.2 2.1 228
15 5 2 10 33.3 15.9 0.0 315
15 5 2 11 36.6 15.7 0.0 315
15 5 2 12 39.6 11.2 0.0 90
15 5 2 13 40.6 10.9 0.0 90
15 5 2 14 43.5 9.3 0.0 22.5
15 5 2 15 41.6 8.2 0.0 90
15 5 2 16 40.6 10.6 0.0 157.5
15 5 2 17 39.5 13.9 0.0 270
15 5 2 18 38.1 14.9 1.2 315
15 5 2 19 36.2 20.9 1.3 225
15 5 2 20 35.6 22.3 1.6 225
15 5 2 21 33.2 19.4 0.0 112.5
15 5 2 22 30.6 18.3 0.0 292.5
15 5 2 23 28.9 17.2 0.5 270
15 5 2 24 27.6 16.7 1.3 315
Page 378
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 3 1 28.9 20.4 1.6 312
15 5 3 2 27.3 22.9 1.5 310
15 5 3 3 26.1 24.3 1.2 45
15 5 3 4 26.7 26.6 1.3 45
15 5 3 5 27.3 27.1 2.2 45
15 5 3 6 28.9 26 1.6 82
15 5 3 7 29.4 25.1 0.0 75
15 5 3 8 30.6 23 2.3 270
15 5 3 9 31.6 20.9 1.5 273
15 5 3 10 32.6 19.6 0.0 270
15 5 3 11 34.8 18.2 0.8 270
15 5 3 12 37.6 17.6 0.1 360
15 5 3 13 40.6 14 0.0 22.5
15 5 3 14 42.9 12.3 0.3 22.5
15 5 3 15 40.5 13 0.7 270
15 5 3 16 40.6 10.9 1.1 22.5
15 5 3 17 38.6 11.3 0.6 270
15 5 3 18 37.6 12.9 0.3 45
15 5 3 19 35.6 13.8 1.1 157.5
15 5 3 20 34.6 15.8 1.2 275
15 5 3 21 33.9 16.9 1.2 292.5
15 5 3 22 32.7 17.9 0.8 312.5
15 5 3 23 33.6 19.2 1.1 182.3
15 5 3 24 32.6 20.3 0.9 292.5
15 5 4 1 32.3 21.2 0.4 337.5
15 5 4 2 32.9 22.9 1.7 225
15 5 4 3 32.1 23.4 0.2 45
15 5 4 4 31.6 23.9 0.0 337.5
15 5 4 5 31.0 20.1 0.0 90
15 5 4 6 31.6 19.3 2.3 225
15 5 4 7 31.9 18.7 1.2 112.5
15 5 4 8 32.6 17.6 0.3 135
15 5 4 9 32.7 16.3 0.6 247.5
15 5 4 10 33.6 15.2 0.1 22.5
15 5 4 11 34.6 14 0.0 67.5
15 5 4 12 36.5 13.2 0.0 67.5
15 5 4 13 39.6 12.8 0.3 360
15 5 4 14 41.6 11.2 0.6 182.3
15 5 4 15 40.6 13.2 0.8 247.5
15 5 4 16 39.5 11.6 0.9 67.5
15 5 4 17 38.1 13.2 0.2 67.5
15 5 4 18 37.6 14.3 0.4 45
15 5 4 19 36.1 16.5 0.9 270
15 5 4 20 35.2 17.3 0.7 22.5
15 5 4 21 34.9 18.2 1.0 112.5
15 5 4 22 33.1 19.3 0.7 157.5
15 5 4 23 32.6 20.1 0.6 315
15 5 4 24 31.6 22.6 1.2 320
15 5 5 1 31.2 23.9 1.7 316
15 5 5 2 29.6 24.1 2.3 320
15 5 5 3 26.5 25.6 3.2 325
15 5 5 4 25.6 23.1 2.9 330
15 5 5 5 25.1 22 3.2 315
15 5 5 6 26.9 20.9 2.3 320
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 5 7 27.6 19.3 0.0 157.5
15 5 5 8 28.1 18.4 0.3 90
15 5 5 9 29.6 16.3 0.2 157.5
15 5 5 10 30.6 15.2 0.1 45
15 5 5 11 33.2 14 0.0 90
15 5 5 12 34.6 13.2 0.0 22.5
15 5 5 13 36.4 11.8 0.5 22.5
15 5 5 14 38.6 10.9 1.1 90
15 5 5 15 39.1 9.2 2.3 271.3
15 5 5 16 38.6 8.2 0.6 157.5
15 5 5 17 37.5 7.6 0.8 45
15 5 5 18 37.1 13.2 1.3 360
15 5 5 19 36.6 12.9 1.2 270
15 5 5 20 35.6 16.5 1.0 270
15 5 5 21 34.1 15.7 0.9 312.5
15 5 5 22 33.2 19.5 1.3 360
15 5 5 23 32.9 20.6 1.3 247.5
15 5 5 24 31.2 23.5 1.1 270
15 5 6 1 30.6 25.6 0.8 270
15 5 6 2 29.7 26.4 0.6 272
15 5 6 3 28.1 25.1 0.0 360
15 5 6 4 27.6 28.6 2.3 135
15 5 6 5 28.1 29.1 0.0 135
15 5 6 6 29.3 28.3 1.2 90
15 5 6 7 30.7 26.1 0.3 67.5
15 5 6 8 31.2 25 1.2 315
15 5 6 9 32.6 24.9 2.3 270
15 5 6 10 33.2 22.9 2.1 45
15 5 6 11 33.4 20.9 0.1 40.5
15 5 6 12 34.9 19.7 0.1 337.5
15 5 6 13 36.6 13.2 1.2 280
15 5 6 14 37.1 12.7 0.0 337.5
15 5 6 15 38.6 10.6 0.0 90
15 5 6 16 37.0 9.4 0.9 135
15 5 6 17 36.6 6.9 1.0 337.5
15 5 6 18 36.1 9.7 1.2 157.5
15 5 6 19 35.1 10.6 1.9 337.5
15 5 6 20 33.2 12.7 0.5 270
15 5 6 21 32.9 13.8 0.5 272
15 5 6 22 30.4 15.6 0.9 270
15 5 6 23 29.3 20.9 1.6 270
15 5 6 24 30.6 21.6 0.1 360
15 5 7 1 30.6 23.6 0.4 22.5
15 5 7 2 29.6 26.9 1.2 292.5
15 5 7 3 29.2 28.1 1.0 315
15 5 7 4 28.1 29.3 0.3 90
15 5 7 5 28.6 30.8 0.8 90
15 5 7 6 29.6 29.1 0.0 135
15 5 7 7 30.2 27.6 0.3 135
15 5 7 8 31.6 25.9 1.9 53.2
15 5 7 9 32.6 20.6 0.6 42.3
15 5 7 10 33.4 19.4 0.3 67.5
15 5 7 11 34.6 18.3 0.0 22.5
15 5 7 12 35.1 15.6 0.0 360
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 7 13 36.3 14.3 0.1 337.5
15 5 7 14 37.6 11 0.4 67.5
15 5 7 15 38.2 9.5 0.9 270
15 5 7 16 38.0 6.5 1.8 225
15 5 7 17 37.3 12.3 1.3 157.5
15 5 7 18 37.6 16.5 1.2 270
15 5 7 19 36.1 19.2 0.6 157.5
15 5 7 20 35.1 20.1 1.0 157.5
15 5 7 21 34.0 21.3 1.3 67.5
15 5 7 22 33.9 23.3 0.9 315
15 5 7 23 32.6 25.6 0.1 315
15 5 7 24 31.8 15.6 0.1 337.5
15 5 8 1 30.6 14.6 0.1 157.5
15 5 8 2 29.6 12.9 1.6 225
15 5 8 3 29.2 16.5 1.9 45
15 5 8 4 28.1 16.2 2.3 45
15 5 8 5 28.6 17.3 1.7 48
15 5 8 6 29.6 15.6 1.5 312.5
15 5 8 7 30.2 14.3 0.8 320
15 5 8 8 31.6 12 2.1 315
15 5 8 9 32.6 11.9 1.6 312
15 5 8 10 33.4 10.6 3.2 310
15 5 8 11 34.6 9.2 2.6 315
15 5 8 12 36.1 8.2 2.9 316
15 5 8 13 37.3 7.1 1.6 320
15 5 8 14 39.6 10.3 1.2 315
15 5 8 15 41.2 11.6 3.2 320
15 5 8 16 39.6 41.2 0.6 318
15 5 8 17 38.3 12.7 0.6 270
15 5 8 18 37.6 16.8 1.5 270
15 5 8 19 36.1 15.2 0.0 157.5
15 5 8 20 35.1 14.3 1.3 135
15 5 8 21 34.0 13.7 1.1 292.5
15 5 8 22 33.9 12.9 1.1 22.5
15 5 8 23 32.6 15.8 0.0 360
15 5 8 24 31.8 16.2 1.6 312.5
15 5 9 1 30.6 19.5 2.1 225
15 5 9 2 29.1 23.6 1.3 270
15 5 9 3 29.6 26.1 2.3 45
15 5 9 4 28.2 36.6 1.6 90
15 5 9 5 27.0 32.4 2.3 270
15 5 9 6 29.3 30 1.5 225
15 5 9 7 30.6 28.1 0.0 175.6
15 5 9 8 31.6 22.3 1.2 45
15 5 9 9 32.9 20.9 2.5 50
15 5 9 10 33.1 19.4 2.3 45
15 5 9 11 34.6 17.6 1.6 45
15 5 9 12 36.5 16.5 1.4 49
15 5 9 13 37.6 15.6 2.2 45
15 5 9 14 39.2 13.2 0.0 337.5
15 5 9 15 38.6 10.6 1.2 225
15 5 9 16 38.0 9.2 1.3 157.5
15 5 9 17 37.6 7.6 1.6 272.3
15 5 9 18 36.9 13.2 3.2 292.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 9 19 33.4 16.9 0.0 292.5
15 5 9 20 32.6 20.6 0.0 247.5
15 5 9 21 31.6 26.8 0.0 157.5
15 5 9 22 30.9 24.3 0.0 292.5
15 5 9 23 29.6 29 1.5 271.1
15 5 9 24 29.0 30.8 0.3 337.5
15 5 10 1 28.6 19.5 1.9 270
15 5 10 2 27.1 23.6 1.5 225
15 5 10 3 27.6 26.1 1.2 275
15 5 10 4 27.0 35.1 0.4 360
15 5 10 5 26.8 32.4 1.5 270.1
15 5 10 6 27.6 30 0.9 315
15 5 10 7 28.6 28.1 0.6 315
15 5 10 8 29.1 22.3 0.0 315
15 5 10 9 30.6 20.9 0.3 315
15 5 10 10 30.7 19.4 0.0 315
15 5 10 11 31.6 17.6 0.0 360
15 5 10 12 34.8 16.5 0.0 337.5
15 5 10 13 37.2 15.6 0.0 45
15 5 10 14 38.6 13.2 0.0 270
15 5 10 15 36.9 10.6 0.8 312.5
15 5 10 16 35.6 9.2 1.3 272.3
15 5 10 17 34.2 8.7 1.5 275.5
15 5 10 18 34.9 13.2 1.0 265.1
15 5 10 19 34.0 16.9 0.6 272
15 5 10 20 33.6 20.6 0.5 45
15 5 10 21 32.9 26.8 0.3 157.5
15 5 10 22 31.6 24.3 0.0 312.5
15 5 10 23 30.6 29 0.4 247.5
15 5 10 24 29.6 28.6 0.0 270
15 5 11 1 29.0 25.6 0.3 45
15 5 11 2 28.6 24.3 0.7 270
15 5 11 3 28.1 23.6 0.1 292.5
15 5 11 4 27.6 28.1 0.9 275
15 5 11 5 28.3 26.1 0.6 270
15 5 11 6 29.1 25.1 0.1 157.5
15 5 11 7 30.6 20.9 2.6 285
15 5 11 8 31.9 19.7 0.0 67.5
15 5 11 9 32.1 18.2 0.0 67.5
15 5 11 10 33.9 17.3 1.2 220.3
15 5 11 11 34.6 15.2 0.0 315
15 5 11 12 35.1 16.9 0.0 337.5
15 5 11 13 36.1 17.9 0.0 337.5
15 5 11 14 38.9 15 0.0 135
15 5 11 15 39.1 19.5 1.6 157.5
15 5 11 16 38.1 16 1.0 292.5
15 5 11 17 38.6 14.6 0.6 315
15 5 11 18 37.1 16.9 0.8 270
15 5 11 19 36.0 20.6 4.1 270
15 5 11 20 35.9 22.1 0.8 157.5
15 5 11 21 34.6 23.9 0.8 360
15 5 11 22 33.2 25.1 0.5 315
15 5 11 23 30.3 26.8 0.4 360
15 5 11 24 29.5 30.9 1.2 225
Page 379
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 12 1 28.5 32.6 0.6 270
15 5 12 2 28.6 33.4 1.5 271.5
15 5 12 3 28.4 34.9 1.4 275
15 5 12 4 27.6 36.1 0.1 135
15 5 12 5 27.0 42.6 0.6 225
15 5 12 6 28.9 36.1 0.1 135
15 5 12 7 29.0 35.9 0.5 67.5
15 5 12 8 30.6 30.2 0.1 112.5
15 5 12 9 31.6 29.1 0.0 157.5
15 5 12 10 34.6 27.6 1.4 270
15 5 12 11 35.9 26.1 0.0 112.5
15 5 12 12 36.1 25.9 0.1 157.5
15 5 12 13 38.6 22 1.5 45
15 5 12 14 39.2 20.9 2.1 49
15 5 12 15 37.3 15.1 2.6 45
15 5 12 16 38.6 14.6 0.3 90
15 5 12 17 37.6 12.9 0.1 135
15 5 12 18 36.9 15.6 0.3 67.5
15 5 12 19 36.5 19 0.9 270
15 5 12 20 35.1 20.6 1.6 225
15 5 12 21 34.0 22.9 0.3 45
15 5 12 22 33.9 25.6 2.5 270
15 5 12 23 32.0 29.1 0.0 157.5
15 5 12 24 33.6 30.6 0.6 157.5
15 5 13 1 31.9 32.6 1.2 275
15 5 13 2 31.6 33.4 3.7 225
15 5 13 3 31.2 34.9 1.1 225
15 5 13 4 30.3 36.1 0.0 67.5
15 5 13 5 31.6 33.1 1.9 270
15 5 13 6 32.9 36.1 0.0 135
15 5 13 7 33.5 35.9 1.9 157.5
15 5 13 8 35.6 30.2 2.3 272
15 5 13 9 36.2 29.1 0.0 360
15 5 13 10 34.6 27.6 0.1 90
15 5 13 11 35.9 26.1 0.0 112.5
15 5 13 12 36.1 25.9 2.6 270
15 5 13 13 38.6 22 1.1 135
15 5 13 14 41.9 20.9 0.0 112.5
15 5 13 15 42.3 15.1 0.0 67.5
15 5 13 16 39.7 14.6 0.0 90
15 5 13 17 38.6 12.9 0.0 157.5
15 5 13 18 37.6 15.6 1.0 67.5
15 5 13 19 36.5 19 0.9 225
15 5 13 20 35.1 20.6 0.9 57.3
15 5 13 21 34.0 22.9 0.3 157.5
15 5 13 22 33.9 25.6 1.4 225
15 5 13 23 32.0 29.1 0.3 48.9
15 5 13 24 33.6 30.6 0.1 53.2
15 5 14 1 31.9 32.6 0.2 292.5
15 5 14 2 30.3 33.9 0.3 22.5
15 5 14 3 29.1 35.9 1.0 360
15 5 14 4 28.3 40.6 0.0 135
15 5 14 5 29.0 46.9 0.6 270
15 5 14 6 30.6 39.1 0.0 312.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 14 7 31.7 35.6 0.7 270
15 5 14 8 32.6 30.9 3.2 225
15 5 14 9 33.6 29.4 0.1 157.5
15 5 14 10 34.6 26.1 1.8 270
15 5 14 11 35.9 23.1 1.6 270
15 5 14 12 37.5 20.9 0.5 67.5
15 5 14 13 39.6 19.4 0.4 90
15 5 14 14 40.3 18.7 0.4 135
15 5 14 15 41.6 16.5 2.6 270
15 5 14 16 39.6 15 1.3 270
15 5 14 17 37.2 16.9 1.6 292.5
15 5 14 18 36.6 19.7 1.7 247.5
15 5 14 19 35.5 22.4 1.6 360
15 5 14 20 35.1 26.8 1.3 157.5
15 5 14 21 36.2 29.1 1.2 157.5
15 5 14 22 35.2 30.9 1.5 157.5
15 5 14 23 34.0 33.8 0.0 157.5
15 5 14 24 33.9 38.7 1.3 270
15 5 15 1 30.6 19.5 0.6 270
15 5 15 2 29.3 23.6 0.8 225
15 5 15 3 30.8 26.1 0.0 112.5
15 5 15 4 29.6 34.6 1.5 270
15 5 15 5 29.0 32.4 2.3 247.5
15 5 15 6 30.6 30 1.5 270
15 5 15 7 31.7 28.1 0.2 43.5
15 5 15 8 32.6 22.3 0.0 337.5
15 5 15 9 33.9 20.9 0.4 315
15 5 15 10 34.0 19.4 0.6 360
15 5 15 11 37.1 17.6 0.2 360
15 5 15 12 38.6 16.5 0.1 22.5
15 5 15 13 39.1 15.6 0.0 135
15 5 15 14 42.3 13.2 2.4 292.5
15 5 15 15 41.3 10.6 0.2 45
15 5 15 16 40.8 9.2 2.5 312.5
15 5 15 17 39.1 16.5 1.3 270
15 5 15 18 38.6 13.2 1.5 312.5
15 5 15 19 38.6 23.7 0.5 157.5
15 5 15 20 37.1 20.6 0.3 157.5
15 5 15 21 36.2 26.8 0.1 90
15 5 15 22 35.6 24.3 0.1 67.5
15 5 15 23 34.1 29 0.0 157.5
15 5 15 24 33.2 28.6 0.3 90
15 5 16 1 32.8 20.4 0.7 22.5
15 5 16 2 29.3 22.9 1.3 292.5
15 5 16 3 30.8 24.3 0.2 135
15 5 16 4 29.6 26.6 0.3 157.5
15 5 16 5 29.0 27.1 0.3 90
15 5 16 6 30.6 26 1.2 312.5
15 5 16 7 31.7 25.1 0.8 270
15 5 16 8 32.6 23 1.2 185
15 5 16 9 33.9 20.9 1.4 187.3
15 5 16 10 34.0 19.6 1.3 270.2
15 5 16 11 37.1 18.2 2.3 270
15 5 16 12 38.6 17.6 0.3 45.1
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 16 13 39.1 14 0.4 90
15 5 16 14 40.3 12.3 1.0 270
15 5 16 15 41.3 13 1.0 45
15 5 16 16 40.8 7.1 1.2 315
15 5 16 17 39.1 11.3 1.5 312.5
15 5 16 18 38.6 12.9 1.3 51.3
15 5 16 19 38.6 13.8 0.6 90
15 5 16 20 37.1 15.8 0.8 90
15 5 16 21 36.2 16.9 1.7 270
15 5 16 22 35.6 17.9 0.3 43.2
15 5 16 23 34.1 19.2 0.8 292.5
15 5 16 24 33.2 20.3 1.6 225
15 5 17 1 32.8 17.6 0.7 270
15 5 17 2 31.6 17.9 0.9 90
15 5 17 3 31.2 18.6 0.9 45
15 5 17 4 30.8 19.8 0.2 337.5
15 5 17 5 31.6 18 1.2 90
15 5 17 6 31.9 19.6 1.3 135
15 5 17 7 32.6 18.6 1.1 157.5
15 5 17 8 33.6 17.6 1.1 270
15 5 17 9 34.6 15.6 2.3 270
15 5 17 10 36.5 16.2 1.1 247.5
15 5 17 11 38.1 16.9 1.1 45
15 5 17 12 39.0 17.6 1.6 360
15 5 17 13 40.9 14.6 1.2 45
15 5 17 14 42.6 13.9 1.2 45
15 5 17 15 42.6 11 1.1 157.5
15 5 17 16 43.1 10.9 2.1 315
15 5 17 17 41.2 8.6 0.9 157.5
15 5 17 18 40.6 6.3 1.1 312.5
15 5 17 19 39.3 9.3 0.6 315
15 5 17 20 38.1 10.6 0.7 315
15 5 17 21 37.6 11.9 0.7 360
15 5 17 22 36.2 13.7 0.8 22.5
15 5 17 23 35.4 15.9 1.2 220
15 5 17 24 34.1 16.8 3.2 315
15 5 18 1 33.6 17.9 0.4 337.5
15 5 18 2 32.3 19.2 2.1 247.5
15 5 18 3 31.6 23.5 0.6 337.5
15 5 18 4 30.2 26.5 0.9 90
15 5 18 5 30.6 28.1 0.8 90
15 5 18 6 31.5 20.9 0.6 90
15 5 18 7 32.0 19.4 1.2 312.5
15 5 18 8 33.4 18.3 0.0 157.5
15 5 18 9 34.1 16 0.6 22.5
15 5 18 10 35.6 13.2 0.0 22.5
15 5 18 11 36.2 10.8 1.2 360
15 5 18 12 37.1 9.4 0.0 90
15 5 18 13 40.6 15.6 0.0 337.5
15 5 18 14 42.1 16.9 0.3 135
15 5 18 15 40.6 10.2 0.3 45
15 5 18 16 38.9 9.1 0.2 67.5
15 5 18 17 39.6 6.3 0.9 356
15 5 18 18 38.6 19.2 0.8 22.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 18 19 39.1 20.9 0.0 67.5
15 5 18 20 38.2 23.4 1.4 90
15 5 18 21 37.0 26.9 0.0 67.5
15 5 18 22 36.9 26.1 0.0 337.5
15 5 18 23 37.6 27.1 2.3 225
15 5 18 24 38.2 28.6 0.0 360
15 5 19 1 37.6 30.2 0.7 46
15 5 19 2 37.2 31.6 0.7 52
15 5 19 3 37.6 32.9 2.3 315
15 5 19 4 36.5 36.35 3.2 45
15 5 19 5 37.6 38.1 2.1 50
15 5 19 6 38.1 32.1 1.9 45
15 5 19 7 39.2 30.9 2.1 51
15 5 19 8 38.1 29.1 0.0 50
15 5 19 9 37.9 27.2 0.0 315
15 5 19 10 38.1 25 1.2 235.6
15 5 19 11 39.2 22.8 1.2 215.4
15 5 19 12 40.6 20.9 1.4 22.5
15 5 19 13 40.3 18.7 0.4 360
15 5 19 14 42.8 16.5 2.3 315
15 5 19 15 41.3 15.2 2.1 337.5
15 5 19 16 40.6 8.8 3.1 22.5
15 5 19 17 39.2 13 3.0 337.5
15 5 19 18 38.1 16 1.6 360
15 5 19 19 37.6 19 0.7 360
15 5 19 20 38.6 23.1 0.0 22.5
15 5 19 21 39.1 26.9 0.0 45
15 5 19 22 39.8 28.1 0.0 360
15 5 19 23 39.7 32.1 2.3 270
15 5 19 24 38.2 33.9 1.6 229
15 5 20 1 37.6 30.2 1.3 218.5
15 5 20 2 8.2 31.6 0.0 22.5
15 5 20 3 38.6 32.9 1.2 45
15 5 20 4 37.1 36.35 1.9 48
15 5 20 5 36.6 38.1 2.3 45
15 5 20 6 37.6 32.1 1.6 312.5
15 5 20 7 37.2 30.9 1.4 225
15 5 20 8 38.6 29.1 0.0 247.5
15 5 20 9 39.1 27.2 0.8 315
15 5 20 10 40.6 25 0.0 247.5
15 5 20 11 39.2 22.8 1.2 292.5
15 5 20 12 38.1 20.9 0.0 90
15 5 20 13 40.6 18.7 3.1 43.2
15 5 20 14 40.6 16.5 2.7 45
15 5 20 15 39.5 15.2 0.0 90
15 5 20 16 38.1 10.7 0.3 67.5
15 5 20 17 37.6 13 2.2 90
15 5 20 18 38.6 16 0.0 90
15 5 20 19 39.1 19 0.6 67.5
15 5 20 20 37.1 23.1 0.5 67.5
15 5 20 21 39.1 26.9 0.0 360
15 5 20 22 38.6 28.1 0.0 360
15 5 20 23 37.0 32.1 1.2 225
15 5 20 24 37.6 33.9 1.2 225
Page 380
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 21 1 39.4 29.1 1.2 157.5
15 5 21 2 38.5 28.6 0.0 157.5
15 5 21 3 37.6 26.1 0.5 157.5
15 5 21 4 35.6 29.1 1.2 270
15 5 21 5 31.6 30.6 1.2 312.5
15 5 21 6 35.6 28.1 0.6 312.5
15 5 21 7 35.6 26.8 2.1 247.5
15 5 21 8 34.6 25.1 0.0 360
15 5 21 9 36.3 22.3 2.3 43.5
15 5 21 10 38.6 21.6 2.3 48.9
15 5 21 11 39.6 20.9 0.0 360
15 5 21 12 40.6 19.3 0.6 67.5
15 5 21 13 41.4 18.2 1.1 67.5
15 5 21 14 42.9 17.3 1.6 90
15 5 21 15 40.1 15.1 1.5 90
15 5 21 16 39.1 13.2 0.0 90
15 5 21 17 36.5 11.4 0.0 67.5
15 5 21 18 35.1 15.6 0.0 90
15 5 21 19 34.6 16.9 0.0 22.5
15 5 21 20 33.2 17.3 0.0 67.5
15 5 21 21 33.1 18.2 0.0 90
15 5 21 22 32.0 19 0.0 90
15 5 21 23 32.6 20.9 0.6 337.5
15 5 21 24 33.8 21.3 0.0 360
15 5 22 1 32.6 22.6 1.7 225
15 5 22 2 30.4 23.4 1.3 312.5
15 5 22 3 28.6 25.6 0.8 225
15 5 22 4 26.3 33.4 3.2 270
15 5 22 5 24.2 29.1 1.5 312.5
15 5 22 6 24.5 30.6 0.0 315
15 5 22 7 28.3 29.8 0.0 315
15 5 22 8 29.1 27.6 1.3 312.5
15 5 22 9 29.4 25.1 0.0 315
15 5 22 10 30.5 23.1 0.0 22.5
15 5 22 11 33.7 20.9 0.3 67.5
15 5 22 12 35.2 19.5 0.0 90
15 5 22 13 38.9 18.1 1.1 67.5
15 5 22 14 41.2 15.6 1.6 48.9
15 5 22 15 40.3 10.6 1.1 43
15 5 22 16 38.2 9.5 0.0 337.5
15 5 22 17 37.1 5.2 1.5 22.5
15 5 22 18 36.8 10.6 0.4 135
15 5 22 19 35.5 19.8 1.3 337.5
15 5 22 20 34.4 20.6 2.5 45
15 5 22 21 33.6 23.4 2.4 48
15 5 22 22 31.8 25.9 1.6 45
15 5 22 23 31.5 26.1 1.6 312.5
15 5 22 24 30.3 29.1 1.5 312.5
15 5 23 1 29.6 22.6 0.0 270
15 5 23 2 28.2 19.2 0.0 270
15 5 23 3 27.5 20.6 0.0 292.5
15 5 23 4 27.6 23.1 0.0 315
15 5 23 5 27.1 20.6 0.0 337.5
15 5 23 6 28.0 19.6 1.2 222.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 23 7 28.9 18.1 0.0 157.5
15 5 23 8 33.2 23.6 0.0 270
15 5 23 9 34.1 19.5 0.0 337.5
15 5 23 10 35.3 18.2 1.2 247.5
15 5 23 11 37.2 17.6 0.6 67.5
15 5 23 12 38.7 19.5 2.9 135
15 5 23 13 39.5 18.1 2.2 135
15 5 23 14 40.5 15.6 2.9 112.5
15 5 23 15 41.2 10.6 1.3 157.5
15 5 23 16 40.3 9.5 1.5 112.5
15 5 23 17 39.4 5.2 1.1 90
15 5 23 18 39.5 10.6 1.9 90
15 5 23 19 38.6 19.8 0.9 235
15 5 23 20 37.5 20.6 1.5 235
15 5 23 21 36.2 23.4 1.2 67.5
15 5 23 22 35.3 20.6 0.0 90
15 5 23 23 33.7 19.5 0.0 90
15 5 23 24 32.5 18.3 0.3 56.2
15 5 24 1 31.6 20.6 0.0 292.5
15 5 24 2 31.2 21.9 0.8 247.5
15 5 24 3 30.4 23.9 0.5 312.5
15 5 24 4 28.2 26.1 1.2 225
15 5 24 5 29.3 29.1 0.0 247.5
15 5 24 6 30.2 28.1 0.0 312.5
15 5 24 7 31.5 26.9 0.0 360
15 5 24 8 33.6 25 0.0 360
15 5 24 9 34.8 20.6 0.0 292.5
15 5 24 10 35.4 19.4 0.0 360
15 5 24 11 36.3 19.2 0.6 157.5
15 5 24 12 37.5 22.6 0.0 157.5
15 5 24 13 42.2 25.6 1.1 312.5
15 5 24 14 42.4 23.1 1.2 292.5
15 5 24 15 40.6 22 0.4 360
15 5 24 16 39.4 19.2 0.6 90
15 5 24 17 38.5 18.4 0.9 22.5
15 5 24 18 38.7 19.6 1.3 216.5
15 5 24 19 37.4 21.6 1.5 315
15 5 24 20 36.9 22.6 1.6 45
15 5 24 21 35.4 23.8 2.8 48
15 5 24 22 33.6 26.5 3.6 45
15 5 24 23 31.2 27.1 3.2 45
15 5 24 24 30.5 28.4 0.9 45
15 5 25 1 28.3 20.6 0.0 45
15 5 25 2 27.6 21.9 2.5 312.5
15 5 25 3 27.4 23.9 0.0 312.5
15 5 25 4 26.5 40.9 0.0 312.5
15 5 25 5 28.6 43.6 0.0 312.5
15 5 25 6 30.9 38.1 0.0 312.5
15 5 25 7 31.2 26.9 0.0 67.5
15 5 25 8 33.5 25 0.0 312.5
15 5 25 9 36.1 26.1 0.0 225
15 5 25 10 38.5 27.6 0.0 337.5
15 5 25 11 39.6 28.9 1.3 225
15 5 25 12 40.2 29.1 1.2 312.5
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 25 13 40.5 27.1 0.0 315
15 5 25 14 41.3 26.1 2.6 212.5
15 5 25 15 40.6 25 1.4 315
15 5 25 16 39.5 24.9 1.2 315
15 5 25 17 38.6 23.4 1.6 275
15 5 25 18 37.4 25.6 0.0 157.5
15 5 25 19 36.2 26.9 0.0 157.5
15 5 25 20 34.2 27.1 0.0 157.5
15 5 25 21 33.9 28.9 0.0 157.5
15 5 25 22 33.1 29.1 1.5 270
15 5 25 23 31.3 30.6 1.3 270
15 5 25 24 30.7 31.6 4.2 225
15 5 26 1 29.4 17.9 0.0 112.5
15 5 26 2 28.5 19.2 0.8 270
15 5 26 3 27.3 23.5 0.0 247.5
15 5 26 4 26.4 26.5 0.0 270
15 5 26 5 27.9 28.1 3.2 46.8
15 5 26 6 28.5 20.9 1.8 320
15 5 26 7 31.4 19.4 1.4 315
15 5 26 8 34.3 18.3 1.7 220.7
15 5 26 9 36.2 16 0.0 360
15 5 26 10 37.5 13.2 1.3 223.5
15 5 26 11 38.6 10.8 0.0 135
15 5 26 12 39.5 9.4 0.6 216
15 5 26 13 40.8 15.6 0.3 45
15 5 26 14 41.3 16.9 0.9 211.2
15 5 26 15 40.2 10.2 1.4 270
15 5 26 16 39.8 9.1 1.6 312.5
15 5 26 17 39.2 6.3 0.0 157.5
15 5 26 18 38.9 19.2 0.0 157.5
15 5 26 19 38.6 20.9 0.0 90
15 5 26 20 35.8 23.4 0.7 67.5
15 5 26 21 34.6 26.9 0.4 157.5
15 5 26 22 33.2 26.1 0.5 337.5
15 5 26 23 32.6 27.1 0.0 22.5
15 5 26 24 31.5 28.6 1.2 292.5
15 5 27 1 30.2 30.2 0.0 135
15 5 27 2 29.6 31.6 0.0 157.5
15 5 27 3 28.9 32.9 0.0 90
15 5 27 4 27.1 36.3 2.5 312.5
15 5 27 5 27.3 38.1 3.2 46.8
15 5 27 6 28.5 32.1 1.8 222.5
15 5 27 7 28.7 30.9 0.7 230.1
15 5 27 8 30.4 29.1 1.2 49.7
15 5 27 9 31.5 27.2 0.0 270
15 5 27 10 32.6 25 0.4 45.2
15 5 27 11 33.5 22.8 0.0 90
15 5 27 12 35.6 20.9 1.5 270
15 5 27 13 37.2 18.7 0.0 45
15 5 27 14 40.9 16.5 1.3 315
15 5 27 15 39.8 15.2 0.0 312.5
15 5 27 16 38.7 8.8 0.0 312.5
15 5 27 17 36.8 13 0.6 43.8
15 5 27 18 35.6 16 0.9 56.7
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 27 19 34.5 19 1.2 270
15 5 27 20 33.6 23.1 0.0 337.5
15 5 27 21 32.4 26.9 1.5 226.3
15 5 27 22 31.5 28.1 1.2 225
15 5 27 23 30.8 32.1 0.0 270
15 5 27 24 30.2 33.9 0.0 337.5
15 5 28 1 31.6 30.2 0.0 45
15 5 28 2 31.2 31.6 1.3 235.4
15 5 28 3 30.4 32.9 0.0 90
15 5 28 4 28.2 36.3 1.3 46.9
15 5 28 5 29.3 38.1 0.7 157.5
15 5 28 6 30.2 32.1 1.6 270
15 5 28 7 31.5 30.9 0.5 270
15 5 28 8 33.6 29.1 1.1 247.5
15 5 28 9 34.8 27.2 1.0 45
15 5 28 10 35.4 25 0.9 235.4
15 5 28 11 36.3 22.8 0.3 45
15 5 28 12 37.5 20.9 0.6 45
15 5 28 13 38.2 18.7 0.0 157.5
15 5 28 14 39.6 16.5 0.0 315
15 5 28 15 42.2 15.2 0.0 157.5
15 5 28 16 42.4 10.7 1.3 312.5
15 5 28 17 39.5 13 0.0 315
15 5 28 18 38.7 16 0.0 315
15 5 28 19 37.4 19 0.0 360
15 5 28 20 36.9 23.1 2.3 260
15 5 28 21 35.4 26.9 1.6 270
15 5 28 22 33.6 28.1 0.0 315
15 5 28 23 31.2 32.1 0.0 46.2
15 5 28 24 30.5 33.9 1.2 247.5
15 5 29 1 28.3 29.1 0.0 53.2
15 5 29 2 27.6 28.6 0.9 75.5
15 5 29 3 27.4 26.1 0.0 90
15 5 29 4 26.5 29.1 1.6 90
15 5 29 5 28.6 30.6 1.0 230.6
15 5 29 6 30.9 28.1 1.2 216.4
15 5 29 7 31.2 26.8 0.8 22.5
15 5 29 8 33.5 25.1 0.0 22.5
15 5 29 9 36.1 22.3 0.0 360
15 5 29 10 38.5 21.6 2.2 230.2
15 5 29 11 39.6 20.9 2.3 225.6
15 5 29 12 40.2 19.3 0.4 48.3
15 5 29 13 40.5 18.2 0.0 45
15 5 29 14 41.3 17.3 0.6 67.5
15 5 29 15 41.6 15.1 0.0 90
15 5 29 16 40.5 13.2 0.0 56.2
15 5 29 17 39.6 11.4 1.3 157.5
15 5 29 18 37.4 15.6 2.2 360
15 5 29 19 36.2 16.9 1.3 225
15 5 29 20 34.2 17.3 2.6 270
15 5 29 21 33.9 18.2 1.3 312.5
15 5 29 22 33.1 19 3.2 225
15 5 29 23 31.3 20.9 2.2 360
15 5 29 24 30.7 21.3 0.0 112.5
Page 381
Year Month Date Hour Temperature (°C) Relative Humidity (%) Wind Speed (m/s) Wind Direction (°)
15 5 30 1 29.4 22.6 1.2 225
15 5 30 2 28.5 23.4 1.8 57.3
15 5 30 3 27.3 25.6 2.4 90
15 5 30 4 26.4 33.4 0.7 229.8
15 5 30 5 27.9 29.1 0.6 90
15 5 30 6 28.5 30.6 0.0 112.5
15 5 30 7 31.4 29.8 0.7 157.5
15 5 30 8 34.3 27.6 1.2 90
15 5 30 9 36.2 25.1 0.5 67.5
15 5 30 10 37.5 23.1 0.0 67.5
15 5 30 11 38.6 20.9 2.2 360
15 5 30 12 39.5 19.5 0.0 67.5
15 5 30 13 40.8 18.1 2.6 247.5
15 5 30 14 41.3 15.6 3.2 270
15 5 30 15 40.2 10.6 0.0 292.5
15 5 30 16 39.8 9.5 0.0 52.3
15 5 30 17 39.2 5.2 1.5 270
15 5 30 18 38.9 10.6 0.7 48.3
15 5 30 19 38.6 19.8 0.4 52.8
15 5 30 20 35.8 20.6 0.0 45
15 5 30 21 34.6 23.4 0.0 360
15 5 30 22 33.2 25.9 1.3 270
15 5 30 23 32.6 26.1 2.2 360
15 5 30 24 31.5 29.1 3.2 315
15 5 31 1 30.2 29.1 4.2 320
15 5 31 2 29.6 28.6 0.6 312
15 5 31 3 28.9 26.1 1.0 45
15 5 31 4 27.1 29.1 1.3 49.8
15 5 31 5 27.3 30.6 1.1 52.3
15 5 31 6 28.5 28.1 2.6 52.3
15 5 31 7 28.7 26.8 1.6 49.5
15 5 31 8 30.4 25.1 1.0 315
15 5 31 9 31.5 22.3 0.6 360
15 5 31 10 32.6 21.6 0.0 270
15 5 31 11 33.5 20.9 0.5 67.5
15 5 31 12 35.6 19.3 0.0 90
15 5 31 13 37.2 18.2 0.0 56.2
15 5 31 14 39.8 17.3 0.0 135
15 5 31 15 42.3 15.1 1.6 312.5
15 5 31 16 38.7 13.2 1.3 49.3
15 5 31 17 36.8 11.4 0.0 292.5
15 5 31 18 35.6 15.6 0.0 315
15 5 31 19 34.5 16.9 2.1 312.5
15 5 31 20 33.6 17.3 2.6 270
15 5 31 21 32.4 18.2 2.2 43
15 5 31 22 31.5 19 0.0 157.5
15 5 31 23 30.8 20.9 0.0 157.5
15 5 31 24 30.2 21.3 0.0 90
Page 382
AMBIENT AIR QUALITY LOCATION: SA1 PROJECT SITE (Unit µg/m
3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3) 00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
01.03.2015 7.5 19.4 8.5 22.3 7.9 19.8 68.5 28.9 0.59 BDL
02.03.2015 7.7 18.9 8.7 25.3 8.2 19.2 69.7 30.5 0.63 BDL
08.03.2015 8.2 21.5 9.2 24.8 8.6 22.0 72.8 33.1 0.58 BDL
09.03.2015 7.6 21.6 9.3 23.6 7.9 21.9 68.1 32.8 0.66 BDL
15.03.2015 8.2 20.0 8.6 24.9 8.5 20.5 73.5 36.8 0.62 BDL
16.03.2015 7.9 22.3 9.5 23.0 8.4 22.6 69.5 34.7 0.53 BDL
22.03.2015 8.5 19.8 9.8 24.6 8.9 20.3 73.4 29.5 0.59 BDL
23.03.2015 7.9 21.5 8.6 26.3 8.3 21.9 75.9 33.6 0.62 BDL
29.03.2015 8.3 20.6 9.2 22.0 8.8 21.0 76.2 28.1 0.65 BDL
30.03.2015 8.8 19.3 9.8 23.5 9.2 19.6 72.5 30.2 0.59 BDL
05.04.2015 7.5 18.9 8.7 24.3 8.0 19.4 70.0 33.5 0.53 BDL
06.04.2015 7.7 22.3 9.5 25.6 8.2 22.7 69.4 34.8 0.62 BDL
12.04.2015 8.6 20.8 8.6 22.3 9.1 21.3 73.5 34.2 0.58 BDL
13.04.2015 8.0 21.9 8.9 26.1 8.4 22.3 74.6 35.9 0.64 BDL
19.04.2015 7.6 19.1 9.3 25.3 8.0 19.5 76.2 34.7 0.60 BDL
20.04.2015 7.9 21.3 9.8 23.5 8.3 21.7 72.3 29.0 0.53 BDL
26.04.2015 8.5 20.6 8.6 22.9 9.0 20.9 75.1 28.4 0.58 BDL
27.04.2015 8.3 21.8 8.9 25.8 8.8 22.3 74.6 33.0 0.60 BDL
03.05.2015 7.7 22.0 9.0 23.0 8.2 22.5 70.0 32.8 0.65 BDL
04.05.2015 8.3 22.3 8.6 24.6 8.7 22.7 69.2 34.7 0.53 BDL
10.05.2015 8.8 19.4 9.7 25.8 9.2 19.8 73.3 29.0 0.57 BDL
11.05.2015 7.6 20.6 8.5 24.1 8.0 20.9 71.9 31.4 0.65 BDL
17.05.2015 7.5 19.8 9.6 23.8 7.9 20.3 69.8 35.0 0.61 BDL
18.05.2015 7.7 20.6 9.7 24.6 8.2 20.9 75.1 33.4 0.56 BDL
24.05.2015 8.2 21.4 8.6 25.3 8.6 21.7 76.2 35.8 0.59 BDL
25.05.2015 8.3 22.0 9.2 26.3 8.9 20.5 71.5 36.4 0.62 BDL
SO2 NO2 PM10 PM2.5 CO
Max. 9.8 26.3 76.2 36.8 0.66
Min. 7.5 18.9 68.1 28.1 0.53
95%tile 9.7 25.8 76.2 36.3 0.65
98%tile 9.8 26.2 76.2 36.8 0.66
Page 383
AMBIENT AIR QUALITY
LOCATION: SA2 NIMBETI MINE SITE (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3) 00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
03.03.2015 7.5 20.6 9.0 23.4 8.0 20.9 72.3 30.2 0.56 BDL
04.03.2015 8.2 19.5 8.5 22.5 8.6 20.0 74.4 29.4 0.61 BDL
10.03.2015 7.6 18.4 9.3 24.9 7.9 18.9 81.0 38.1 0.54 BDL
11.03.2015 8.3 21.6 8.2 23.4 8.6 21.9 74.6 33.5 0.59 BDL
17.03.2015 7.3 22.0 9.2 21.7 7.7 22.5 75.8 36.4 0.52 BDL
18.03.2015 8.6 19.8 8.8 23.5 8.9 20.3 73.5 29.7 0.55 BDL
24.03.2015 8.2 21.6 9.0 25.4 8.7 21.9 75.8 37.1 0.60 BDL
25.03.2015 8.0 20.6 8.6 23.0 8.5 20.9 80.3 28.7 0.62 BDL
31.03.2015 7.2 21.9 9.2 24.7 7.7 22.3 71.0 35.9 0.54 BDL
01.04.2015 7.7 19.7 8.6 21.9 7.9 20.2 76.9 37.1 0.58 BDL
07.04.2015 8.3 20.0 9.6 23.6 8.6 20.4 77.2 29.7 0.60 BDL
08.04.2015 7.2 21.4 8.2 24.8 7.7 21.7 79.8 36.4 0.57 BDL
14.04.2015 8.5 19.6 8.8 25.0 9.0 19.9 77.1 34.8 0.53 BDL
15.04.2015 7.4 21.1 9.6 21.8 7.9 21.4 74.6 31.3 0.61 BDL
21.04.2015 8.1 20.6 9.3 22.5 8.6 20.9 72.1 29.5 0.58 BDL
22.04.2015 7.3 19.3 8.4 23.7 7.7 21.6 79.5 30.7 0.52 BDL
28.04.2015 8.6 21.9 9.1 24.1 8.9 22.3 70.1 38.0 0.59 BDL
29.04.2015 7.5 20.7 8.4 22.8 7.9 21.2 74.6 34.6 0.62 BDL
05.05.2015 8.0 21.6 9.0 23.2 8.5 21.9 73.8 37.5 0.55 BDL
06.05.2015 7.7 19.7 8.3 24.6 8.2 20.2 70.1 30.3 0.53 BDL
12.05.2015 8.2 20.8 9.4 25.0 8.6 21.2 73.5 29.4 0.61 BDL
13.05.2015 7.9 18.6 8.8 23.4 8.2 18.9 77.2 36.9 0.57 BDL
19.05.2015 7.2 20.4 9.3 22.3 7.6 20.9 76.1 38.1 0.62 BDL
20.05.2015 8.6 19.1 8.2 24.9 8.9 19.4 72.4 34.1 0.54 BDL
26.05.2015 7.9 21.3 9.1 21.7 8.2 21.6 80.2 33.5 0.59 BDL
27.05.2015 8.0 20.8 8.7 24.6 8.5 21.2 76.8 37.4 0.61 BDL
SO2 NO2 PM10 PM2.5 CO
Max. 9.6 25.4 81.0 38.1 0.62
Min. 7.2 18.4 70.1 28.7 0.52
95%tile 9.3 24.9 80.3 38.1 0.62
98%tile 9.5 25.0 80.7 38.1 0.62
AMBIENT AIR QUALITY
Page 384
LOCATION: SA3 Village Kundal (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3)
00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
05.03.2015 6.2 15.6 7.2 19.3 6.6 15.9 58.2 22.6 BDL BDL
06.03.2015 5.6 17.5 6.5 21.5 5.9 18.0 60.3 21.4 BDL BDL
12.03.2015 6.3 14.2 6.9 22.1 6.7 14.7 66.2 28.2 BDL BDL
13.03.2015 6.0 16.4 7.3 18.2 6.5 16.8 63.7 24.6 BDL BDL
19.03.2015 5.8 18.6 6.7 19.7 6.3 18.9 59.4 22.1 BDL BDL
20.03.2015 6.1 15.8 7.9 20.2 6.5 16.2 57.1 24.9 BDL BDL
26.03.2015 6.3 16.4 6.6 22.1 6.8 16.9 62.4 26.8 BDL BDL
27.03.2015 5.8 14.2 7.0 21.4 6.2 14.6 65.8 24.6 BDL BDL
02.04.2015 6.7 17.9 7.3 19.6 7.1 18.2 59.6 30.2 BDL BDL
03.04.2015 5.7 16.5 6.8 20.2 5.9 16.9 60.1 21.4 BDL BDL
09.04.2015 6.9 14.3 7.5 22.1 7.2 14.6 58.4 24.6 BDL BDL
10.04.2015 5.8 15.8 6.6 22.0 6.3 16.3 59.6 28.7 BDL BDL
16.04.2015 6.3 17.6 7.8 18.5 6.7 17.9 64.5 29.3 BDL BDL
17.04.2015 5.9 18.4 7.1 19.7 6.2 18.9 66.2 24.2 BDL BDL
23.04.2015 6.1 16.5 6.5 21.4 6.6 17.0 63.4 23.4 BDL BDL
24.04.2015 6.4 17.7 7.4 19.5 6.9 18.2 61.5 22.5 BDL BDL
30.04.2015 6.8 18.6 6.9 21.5 7.2 18.9 66.2 21.6 BDL BDL
01.05.2015 5.6 17.5 7.0 22.0 6.1 17.9 59.2 30.0 BDL BDL
07.05.2015 6.7 18.9 6.6 21.6 7.2 19.2 62.4 25.5 BDL BDL
08.05.2015 5.9 17.5 7.1 19.2 6.2 17.9 58.0 24.6 BDL BDL
14.05.2015 6.4 14.5 6.6 18.5 6.8 14.9 60.1 27.9 BDL BDL
15.05.2015 5.8 15.6 7.3 19.4 6.2 16.0 63.3 22.9 BDL BDL
21.05.2015 6.2 17.5 7.8 21.6 6.6 17.9 65.8 27.5 BDL BDL
22.05.2015 6.0 16.4 6.7 22.1 6.5 16.8 61.3 29.0 BDL BDL
28.05.2015 5.7 14.2 7.0 20.4 6.2 14.6 59.7 27.6 BDL BDL
29.05.2015 6.6 16.8 6.8 18.9 6.9 17.2 63.4 25.3 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 7.9 22.1 66.2 30.2
Min. 5.6 14.2 57.1 21.4
95%tile 7.4 22.0 66.2 29.8
98%tile 7.8 22.1 66.2 30.1
Page 385
AMBIENT AIR QUALITY
LOCATION: SA4 sampling station at 500 M (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3)
00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
01.03.2015 6.9 19.6 8.3 22.1 7.2 20.1 66.1 28.6 BDL BDL
02.03.2015 7.1 21.9 9.1 21.5 7.5 22.3 68.2 26.1 BDL BDL
08.03.2015 8.0 20.0 7.8 24.6 8.5 20.4 70.5 28.1 BDL BDL
09.03.2015 7.3 18.0 8.2 22.8 7.6 18.5 75.1 33.5 BDL BDL
15.03.2015 6.4 18.3 8.5 24.8 6.9 18.7 73.9 35.8 BDL BDL
16.03.2015 7.2 19.5 7.9 23.5 7.7 19.9 67.7 27.4 BDL BDL
22.03.2015 6.9 20.6 9.3 21.3 7.2 21.0 73.2 36.2 BDL BDL
23.03.2015 7.0 21.1 8.6 22.8 7.5 21.6 68.5 32.5 BDL BDL
29.03.2015 7.5 18.6 8.0 23.8 8.0 18.9 70.3 27.7 BDL BDL
30.03.2015 8.0 19.2 9.2 21.6 8.5 19.6 66.8 30.4 BDL BDL
05.04.2015 6.8 18.3 8.4 24.0 7.2 18.7 74.2 31.6 BDL BDL
06.04.2015 6.4 20.4 7.8 22.8 6.8 20.9 73.1 33.9 BDL BDL
12.04.2015 7.3 19.9 8.2 21.6 7.7 20.3 70.0 34.1 BDL BDL
13.04.2015 6.8 21.0 8.1 22.7 7.2 21.4 74.4 31.1 BDL BDL
19.04.2015 7.1 19.6 7.8 22.0 7.6 20.0 69.0 33.5 BDL BDL
20.04.2015 7.9 20.3 9.0 24.8 8.2 20.7 75.0 34.9 BDL BDL
26.04.2015 6.5 19.7 9.1 22.6 6.9 20.2 71.6 36.0 BDL BDL
27.04.2015 7.4 20.3 8.5 23.4 7.8 20.6 75.1 29.5 BDL BDL
03.05.2015 6.9 21.0 8.3 21.9 7.2 21.3 72.3 27.4 BDL BDL
04.05.2015 7.0 22.3 8.6 22.5 7.5 22.7 75.0 28.6 BDL BDL
10.05.2015 6.6 18.1 9.0 24.8 6.9 18.6 71.6 30.0 BDL BDL
11.05.2015 7.4 19.6 7.9 24.0 7.9 19.9 72.3 31.2 BDL BDL
17.05.2015 7.7 21.2 8.6 23.7 8.2 21.6 74.9 35.4 BDL BDL
18.05.2015 6.6 21.6 8.8 21.9 6.9 21.9 66.9 36.2 BDL BDL
24.05.2015 8.0 19.7 7.9 22.0 8.5 20.2 73.3 26.1 BDL BDL
25.05.2015 7.5 20.8 9.3 24.3 8.0 21.3 74.9 28.7 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 9.3 24.8 75.1 36.2
Min. 6.4 18.0 66.1 26.1
95%tile 9.1 24.4 75.1 36.2
98%tile 9.3 24.8 75.1 36.2
Page 386
AMBIENT AIR QUALITY
LOCATION: SA5 VILLAGE Kanyakheri (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3)
00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
03.03.2015 7.2 20.6 8.3 23.5 7.6 20.9 68.6 30.2 BDL BDL
04.03.2015 6.6 19.1 9.5 25.2 6.9 19.5 72.5 33.6 BDL BDL
10.03.2015 8.0 18.6 7.7 21.6 8.5 18.9 65.8 34.5 BDL BDL
11.03.2015 7.3 22.0 8.2 22.5 7.7 22.5 72.6 28.8 BDL BDL
17.03.2015 6.9 21.5 9.0 19.9 7.2 21.9 73.5 25.8 BDL BDL
18.03.2015 7.5 19.2 8.6 20.7 7.9 19.6 74.2 33.4 BDL BDL
24.03.2015 6.8 20.3 7.9 21.4 7.2 20.7 66.0 35.8 BDL BDL
25.03.2015 7.2 21.7 8.0 18.9 7.5 22.1 68.9 28.9 BDL BDL
31.03.2015 8.0 22.0 8.5 20.8 8.4 22.4 69.3 26.8 BDL BDL
01.04.2015 7.8 19.3 9.1 22.0 8.3 19.7 70.1 34.1 BDL BDL
07.04.2015 6.6 20.4 9.5 19.7 6.9 20.6 73.5 27.6 BDL BDL
08.04.2015 7.0 19.6 8.6 20.6 7.5 19.9 69.3 29.8 BDL BDL
14.04.2015 6.9 21.7 7.9 21.9 7.2 21.7 72.4 30.0 BDL BDL
15.04.2015 7.5 22.0 8.3 21.1 7.9 22.4 74.0 31.2 BDL BDL
21.04.2015 7.2 18.6 8.0 18.8 7.6 18.9 65.9 35.0 BDL BDL
22.04.2015 8.0 19.3 9.3 19.2 8.4 19.6 74.2 26.8 BDL BDL
28.04.2015 6.7 20.9 7.8 20.6 7.2 20.9 73.0 31.6 BDL BDL
29.04.2015 7.0 21.3 9.5 18.9 7.4 21.6 70.6 27.8 BDL BDL
05.05.2015 6.9 22.0 8.2 20.5 7.3 22.5 68.2 30.1 BDL BDL
06.05.2015 7.3 18.9 8.6 19.7 7.7 19.3 69.4 35.4 BDL BDL
12.05.2015 7.5 19.7 9.1 20.2 8.0 20.3 66.6 28.6 BDL BDL
13.05.2015 6.7 18.6 8.3 22.0 6.9 18.9 65.8 30.4 BDL BDL
19.05.2015 7.3 20.1 7.6 19.8 7.2 20.5 74.0 33.5 BDL BDL
20.05.2015 7.9 21.8 8.8 21.6 8.2 22.2 72.2 28.4 BDL BDL
26.05.2015 8.0 19.0 9.2 18.6 8.4 19.5 69.3 26.0 BDL BDL
27.05.2015 7.3 21.3 8.3 19.5 7.7 21.6 71.0 28.3 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 9.5 25.2 74.2 35.8
Min. 6.6 18.6 65.8 25.8
95%tile 9.2 22.5 74.2 35.3
98%tile 9.5 23.0 74.2 35.6
Page 387
AMBIENT AIR QUALITY
LOCATION: SA6 village Ganeshpura (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3)
00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
05.03.2015 6.3 19.5 7.1 20.7 6.8 20.0 58.1 26.5 BDL BDL
06.03.2015 5.6 20.7 8.5 23.5 5.9 21.2 63.5 31.6 BDL BDL
12.03.2015 7.0 17.2 6.7 24.1 7.4 17.6 64.8 23.5 BDL BDL
13.03.2015 6.9 19.6 7.8 20.6 7.4 19.9 66.4 25.6 BDL BDL
19.03.2015 5.7 21.0 7.5 21.5 5.9 21.5 59.0 28.9 BDL BDL
20.03.2015 6.0 18.3 8.1 23.6 6.5 18.8 60.1 30.2 BDL BDL
26.03.2015 6.8 17.5 6.9 21.4 7.2 18.0 63.4 31.6 BDL BDL
27.03.2015 5.9 19.8 7.0 20.9 6.2 20.1 65.4 27.8 BDL BDL
02.04.2015 6.1 20.3 8.3 24.5 6.5 20.6 68.2 30.3 BDL BDL
03.04.2015 5.8 18.2 6.9 23.5 6.2 18.5 66.9 24.6 BDL BDL
09.04.2015 6.3 19.3 8.5 21.6 6.6 19.6 58.1 25.1 BDL BDL
10.04.2015 7.0 20.0 6.7 20.4 7.5 20.5 64.2 24.6 BDL BDL
16.04.2015 6.5 21.0 7.5 22.2 7.0 21.6 66.5 29.3 BDL BDL
17.04.2015 5.6 18.5 7.0 24.0 5.9 18.9 65.4 31.0 BDL BDL
23.04.2015 6.0 17.3 8.3 21.6 6.5 17.6 67.8 25.8 BDL BDL
24.04.2015 5.9 18.5 6.9 22.4 6.3 19.0 67.7 24.6 BDL BDL
30.04.2015 7.0 20.1 8.2 24.0 7.4 21.5 66.5 31.3 BDL BDL
01.05.2015 6.6 21.0 7.6 18.0 6.9 21.5 64.3 28.5 BDL BDL
07.05.2015 5.9 18.5 6.9 18.5 6.3 19.0 63.4 23.6 BDL BDL
08.05.2015 6.3 20.4 7.1 19.3 6.7 20.9 60.0 27.7 BDL BDL
14.05.2015 6.7 21.6 7.9 21.6 7.2 21.9 59.3 30.1 BDL BDL
15.05.2015 5.8 19.6 8.0 22.7 6.2 20.0 61.2 24.6 BDL BDL
21.05.2015 6.0 17.3 7.0 23.8 6.4 17.7 66.9 23.8 BDL BDL
22.05.2015 5.8 20.2 8.1 24.0 6.2 20.6 68.2 31.5 BDL BDL
28.05.2015 8.0 18.6 7.6 21.6 8.5 19.0 61.2 32.2 BDL BDL
29.05.2015 7.4 20.3 7.9 22.9 7.9 20.7 59.3 29.1 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 8.5 24.5 68.2 32.2
Min. 5.6 17.2 58.1 23.5
95%tile 8.3 24.0 68.1 31.6
98%tile 8.5 24.1 68.2 31.9
Page 388
AMBIENT AIR QUALITY
LOCATION: SA7PATAN (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3)
00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
01.03.2015 5.9 17.6 7.2 20.5 6.3 18.0 59.3 23.5 BDL BDL
02.03.2015 6.1 18.2 8.0 19.7 6.6 18.7 60.1 29.6 BDL BDL
08.03.2015 5.8 16.8 6.7 22.4 6.2 17.4 57.0 30.3 BDL BDL
09.03.2015 7.0 20.0 7.0 20.3 7.4 20.5 67.1 25.4 BDL BDL
15.03.2015 6.5 18.5 8.2 23.1 7.0 18.9 59.5 22.9 BDL BDL
16.03.2015 5.5 17.3 6.9 19.8 6.1 17.6 58.2 24.7 BDL BDL
22.03.2015 6.3 19.5 7.3 21.5 6.7 20.0 57.6 28.2 BDL BDL
23.03.2015 6.9 17.1 7.5 23.0 7.3 17.5 62.4 29.5 BDL BDL
29.03.2015 5.7 20.0 6.7 22.4 6.1 20.4 65.8 23.4 BDL BDL
30.03.2015 7.0 18.9 8.0 20.6 7.5 19.3 66.6 25.6 BDL BDL
05.04.2015 5.6 17.6 6.8 22.2 5.9 17.9 62.2 24.8 BDL BDL
06.04.2015 6.3 18.7 7.2 23.1 6.8 19.2 64.1 27.7 BDL BDL
12.04.2015 6.1 16.8 8.2 20.8 6.5 17.2 63.3 24.3 BDL BDL
13.04.2015 5.9 17.9 6.9 19.7 6.2 18.3 65.4 26.1 BDL BDL
19.04.2015 6.5 19.3 7.2 21.6 7.0 19.7 67.1 27.9 BDL BDL
20.04.2015 7.0 17.5 7.5 20.4 7.5 17.9 58.5 30.1 BDL BDL
26.04.2015 5.7 18.2 8.0 23.0 6.1 18.6 59.2 23.0 BDL BDL
27.04.2015 6.8 19.0 6.8 22.3 7.2 19.5 60.6 25.3 BDL BDL
03.05.2015 6.0 16.9 7.1 20.7 6.5 17.3 62.1 28.4 BDL BDL
04.05.2015 5.8 18.7 7.9 19.9 6.2 19.0 62.0 24.1 BDL BDL
10.05.2015 6.3 17.2 6.7 20.1 6.6 17.6 64.2 28.9 BDL BDL
11.05.2015 7.0 19.0 7.0 21.3 7.4 19.3 57.9 29.0 BDL BDL
17.05.2015 5.9 16.8 8.0 23.0 6.3 17.2 59.4 22.9 BDL BDL
18.05.2015 5.5 18.6 7.5 21.6 5.9 19.0 59.7 24.6 BDL BDL
24.05.2015 6.4 20.0 7.8 19.9 6.8 20.4 61.1 25.0 BDL BDL
25.05.2015 6.9 17.6 6.7 20.5 7.2 17.9 57.0 27.3 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 8.2 23.1 67.1 30.3
Min. 5.5 16.8 57.0 22.9
95%tile 8.0 23.0 67.0 30.0
98%tile 8.1 23.1 67.1 30.2
Page 389
AMBIENT AIR QUALITY
LOCATION: SA8VILLAGE DEVGARH (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3) 00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
03.03.2015 6.2 18.5 6.9 21.6 6.7 19.0 59.2 24.5 BDL BDL
04.03.2015 5.8 20.1 8.0 23.4 6.2 20.5 57.6 30.6 BDL BDL
10.03.2015 6.9 16.8 7.3 22.8 7.3 17.2 65.4 32.1 BDL BDL
11.03.2015 5.8 18.6 8.5 20.2 6.2 19.0 68.4 24.5 BDL BDL
17.03.2015 7.1 16.0 7.3 19.8 7.5 16.5 59.0 23.6 BDL BDL
18.03.2015 6.2 19.8 8.1 24.0 6.7 20.2 61.5 26.2 BDL BDL
24.03.2015 5.8 20.0 7.2 23.7 6.2 20.4 65.0 28.6 BDL BDL
25.03.2015 6.5 15.5 8.4 22.6 7.0 16.0 63.4 30.4 BDL BDL
31.03.2015 5.9 19.2 6.9 20.1 6.2 19.7 66.6 31.7 BDL BDL
01.04.2015 6.3 17.3 7.6 21.3 6.7 17.8 60.1 24.6 BDL BDL
07.04.2015 5.8 16.7 7.8 22.5 6.2 17.1 59.9 23.6 BDL BDL
08.04.2015 6.1 18.5 6.4 24.8 6.5 19.0 61.4 30.9 BDL BDL
14.04.2015 7.0 16.4 8.0 22.7 7.4 16.8 64.2 31.4 BDL BDL
15.04.2015 6.5 19.6 8.2 23.4 7.0 20.2 63.0 25.8 BDL BDL
21.04.2015 5.9 20.0 7.3 19.9 6.2 20.5 67.4 24.6 BDL BDL
22.04.2015 6.0 15.9 8.1 22.4 6.3 16.3 64.3 26.0 BDL BDL
28.04.2015 6.7 17.6 7.6 23.9 7.2 18.0 58.5 24.3 BDL BDL
29.04.2015 7.1 19.8 6.9 21.1 7.5 20.2 68.4 27.8 BDL BDL
05.05.2015 5.8 17.3 8.5 20.6 6.2 17.7 57.6 29.3 BDL BDL
06.05.2015 7.0 16.0 7.7 19.8 7.4 16.5 61.3 30.4 BDL BDL
12.05.2015 6.1 17.3 7.2 20.3 6.6 17.6 65.8 32.0 BDL BDL
13.05.2015 5.8 18.5 6.9 23.2 6.2 19.0 60.4 31.4 BDL BDL
19.05.2015 6.3 19.8 8.2 24.8 6.7 20.2 59.8 28.7 BDL BDL
20.05.2015 6.7 20.0 7.9 19.9 7.2 20.5 62.7 24.8 BDL BDL
26.05.2015 7.1 16.4 8.5 21.4 7.5 16.9 66.3 26.7 BDL BDL
27.05.2015 6.0 15.5 7.7 22.8 6.4 16.1 68.0 28.6 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 8.5 24.8 68.4 32.1
Min. 5.8 15.5 57.6 23.6
95%tile 8.2 23.7 68.3 31.9
98%tile 8.5 24.4 68.4 32.1
Page 390
AMBIENT AIR QUALITY
LOCATION: SA9 VILLAGE RAS (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3) 00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
05.03.2015 6.2 16.9 7.6 20.5 6.8 17.3 65.9 28.6 BDL BDL
06.03.2015 5.8 18.5 8.5 24.6 6.2 19.0 63.1 34.2 BDL BDL
12.03.2015 7.0 20.1 9.0 22.7 7.5 20.5 63.4 25.9 BDL BDL
13.03.2015 6.5 18.6 7.9 25.1 7.0 18.9 73.1 28.6 BDL BDL
19.03.2015 5.9 17.4 8.1 21.8 6.2 17.9 66.5 25.1 BDL BDL
20.03.2015 6.2 19.0 7.2 23.5 6.7 19.4 68.4 34.2 BDL BDL
26.03.2015 7.2 16.2 8.3 22.3 7.5 16.7 69.1 29.5 BDL BDL
27.03.2015 5.8 18.5 8.8 20.0 6.2 18.9 70.0 26.2 BDL BDL
02.04.2015 7.5 19.7 7.6 21.7 8.0 20.1 71.6 28.4 BDL BDL
03.04.2015 6.3 20.0 8.0 23.6 6.8 20.4 72.9 30.1 BDL BDL
09.04.2015 6.1 16.9 9.0 24.5 6.5 17.4 68.2 33.5 BDL BDL
10.04.2015 5.9 18.6 8.8 23.8 6.2 18.9 64.1 25.1 BDL BDL
16.04.2015 7.2 20.1 7.6 22.9 7.5 20.5 63.2 28.9 BDL BDL
17.04.2015 6.5 18.5 7.3 25.0 7.0 19.0 70.2 26.6 BDL BDL
23.04.2015 5.9 16.8 8.6 20.9 6.2 17.2 73.1 28.4 BDL BDL
24.04.2015 6.3 17.9 9.0 23.5 6.7 18.2 66.3 26.5 BDL BDL
30.04.2015 7.2 19.1 7.3 24.6 7.5 19.4 63.1 25.6 BDL BDL
01.05.2015 6.6 20.0 8.0 22.2 6.9 20.4 67.7 28.5 BDL BDL
07.05.2015 5.9 18.6 8.2 25.0 6.2 19.0 69.0 25.1 BDL BDL
08.05.2015 6.3 19.5 7.9 24.7 6.7 19.9 72.5 30.0 BDL BDL
14.05.2015 6.8 20.1 9.0 23.6 7.3 20.5 70.8 32.6 BDL BDL
15.05.2015 7.2 17.8 8.5 24.5 7.6 18.3 72.2 34.2 BDL BDL
21.05.2015 7.0 19.7 8.8 22.8 7.5 20.2 65.4 31.6 BDL BDL
22.05.2015 6.4 20.0 7.6 25.0 7.0 20.4 69.9 25.6 BDL BDL
28.05.2015 7.5 16.8 7.2 24.0 8.0 17.2 70.2 27.7 BDL BDL
29.05.2015 6.4 18.5 8.7 23.7 6.9 19.0 71.6 28.0 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 9.0 25.1 73.1 34.2
Min. 5.8 16.2 63.1 25.1
95%tile 8.8 24.8 73.1 34.2
98%tile 9.0 25.0 73.1 34.2
Page 391
AMBIENT AIR QUALITY
LOCATION: SA10 VILLAGE NIMBETI (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3) 00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
01.03.2015 6.2 16.9 7.5 21.5 6.7 17.3 60.2 29.3 BDL BDL
02.03.2015 7.0 18.5 8.2 24.9 7.4 19.0 63.5 26.5 BDL BDL
08.03.2015 5.6 20.0 6.7 19.7 5.9 20.4 68.1 24.2 BDL BDL
09.03.2015 5.9 15.8 7.2 20.1 7.0 16.2 58.2 32.1 BDL BDL
15.03.2015 6.7 17.6 8.8 22.3 7.2 17.9 61.5 26.8 BDL BDL
16.03.2015 5.8 16.2 8.0 24.5 6.2 16.7 63.8 24.6 BDL BDL
22.03.2015 6.0 15.8 7.5 24.9 6.5 16.3 66.7 25.3 BDL BDL
23.03.2015 6.8 18.2 6.8 23.3 7.2 18.6 68.0 28.9 BDL BDL
29.03.2015 5.7 19.6 7.3 24.6 6.3 20.0 61.5 29.3 BDL BDL
30.03.2015 6.3 17.5 8.2 19.7 6.8 17.9 59.6 27.8 BDL BDL
05.04.2015 6.9 16.8 8.5 20.3 7.2 17.2 58.2 24.8 BDL BDL
06.04.2015 5.8 17.6 6.9 24.6 6.1 17.9 64.4 25.9 BDL BDL
12.04.2015 6.1 19.5 7.0 22.8 6.3 20.0 65.5 30.1 BDL BDL
13.04.2015 7.0 20.0 7.6 21.3 7.4 20.4 68.1 32.0 BDL BDL
19.04.2015 6.5 17.7 8.0 20.5 6.9 18.3 62.0 25.8 BDL BDL
20.04.2015 5.9 16.3 6.9 22.6 6.3 16.7 64.7 24.7 BDL BDL
26.04.2015 6.2 18.5 7.3 24.8 6.6 19.0 65.1 28.8 BDL BDL
27.04.2015 6.6 16.2 8.7 21.6 6.9 16.6 59.3 31.5 BDL BDL
03.05.2015 7.0 17.6 7.5 21.3 7.4 17.9 60.4 30.1 BDL BDL
04.05.2015 6.8 19.5 7.9 22.5 7.2 20.0 67.0 28.9 BDL BDL
10.05.2015 5.9 17.4 8.2 24.6 6.2 17.9 64.9 25.0 BDL BDL
11.05.2015 6.3 16.5 8.0 19.7 6.6 17.0 58.6 30.3 BDL BDL
17.05.2015 7.0 18.0 8.8 23.6 7.4 18.5 62.4 31.7 BDL BDL
18.05.2015 6.5 15.8 7.6 22.5 7.0 16.2 63.8 28.5 BDL BDL
24.05.2015 6.7 16.4 6.7 24.6 6.9 16.9 66.6 30.4 BDL BDL
25.05.2015 5.6 19.3 7.2 22.5 5.9 19.7 67.0 30.6 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 8.8 24.9 68.1 32.1
Min. 5.6 15.8 58.2 24.2
95%tile 8.3 24.6 68.1 31.9
98%tile 8.8 24.9 68.1 32.1
Page 392
AMBIENT AIR QUALITY
LOCATION: SA11 NEAR RESERVE FOREST (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/ m
3)
HC
(mg/ m3) 00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
03.03.2015 5.5 14.8 6.4 18.6 5.9 15.3 59.1 21.4 BDL BDL
04.03.2015 6.2 16.5 7.0 17.7 6.7 17.0 62.5 26.5 BDL BDL
10.03.2015 5.2 18.0 6.3 20.1 5.6 18.5 56.2 20.6 BDL BDL
11.03.2015 6.3 15.6 7.1 21.0 6.8 15.9 60.8 22.4 BDL BDL
17.03.2015 5.6 16.2 6.5 18.5 5.9 16.7 59.4 25.2 BDL BDL
18.03.2015 6.0 17.6 6.8 17.7 6.5 17.9 61.3 22.6 BDL BDL
24.03.2015 5.7 18.0 7.0 18.2 6.0 18.4 58.4 24.5 BDL BDL
25.03.2015 6.3 16.2 6.2 19.6 6.7 16.5 64.1 28.1 BDL BDL
31.03.2015 5.7 14.9 6.9 17.3 6.1 15.3 61.7 21.4 BDL BDL
01.04.2015 6.0 16.0 7.1 20.9 6.4 16.4 56.9 23.7 BDL BDL
07.04.2015 5.6 17.6 6.3 21.0 5.9 17.9 60.3 25.4 BDL BDL
08.04.2015 5.9 18.3 6.0 17.9 6.2 18.5 57.4 21.9 BDL BDL
14.04.2015 6.1 15.5 7.0 18.4 6.5 16.0 61.5 26.2 BDL BDL
15.04.2015 5.9 16.2 6.2 19.3 6.3 16.7 59.2 24.1 BDL BDL
21.04.2015 6.3 18.0 6.8 21.0 6.7 18.4 63.1 28.1 BDL BDL
22.04.2015 5.3 14.9 6.6 18.6 5.8 15.3 58.7 21.3 BDL BDL
28.04.2015 6.2 16.3 6.0 17.7 6.6 16.7 60.8 24.8 BDL BDL
29.04.2015 5.5 15.8 7.0 19.1 5.9 16.3 63.6 22.5 BDL BDL
05.05.2015 5.3 19.4 6.5 20.3 6.2 19.8 59.1 25.3 BDL BDL
06.05.2015 5.7 16.2 6.1 19.2 6.2 16.6 60.2 23.7 BDL BDL
12.05.2015 6.0 17.3 7.1 20.0 6.5 17.6 63.1 28.1 BDL BDL
13.05.2015 5.6 15.5 6.3 18.4 5.9 16.0 59.3 26.9 BDL BDL
19.05.2015 6.3 14.8 6.7 20.3 6.8 15.3 56.5 24.5 BDL BDL
20.05.2015 5.2 17.6 7.0 21.0 5.7 17.9 60.4 21.7 BDL BDL
26.05.2015 5.5 15.2 6.8 17.9 5.9 15.6 57.5 26.5 BDL BDL
27.05.2015 6.1 16.1 6.3 19.5 6.5 16.4 61.2 23.4 BDL BDL
SO2 NO PM10 PM2.5
Max. 7.1 21.0 64.1 28.1
Min. 5.2 14.8 56.2 20.6
95%tile 7.0 20.9 63.5 28.1
98%tile 7.1 21.0 63.9 28.1
Page 393
AMBIENT AIR QUALITY
LOCATION: SA12 VILLAGE BHIMGARH (Unit µg/m3)
DATE OF
MONITORING
CLOCK HOURS CO
(mg/
m3)
HC
(mg/ m3) 00 – 08 08 – 16 16-24 24
HOURS
PM10
24
HOURS
PM2.5 SO2 NO2 SO2 NO2 SO2 NO2
05.03.2015 6.1 18.6 8.5 22.5 6.4 19.0 70.6 30.2 BDL BDL
06.03.2015 5.9 17.8 9.0 25.1 6.3 18.3 67.3 29.4 BDL BDL
12.03.2015 7.0 21.2 7.3 21.0 7.4 21.4 74.1 32.5 BDL BDL
13.03.2015 6.2 18.6 7.9 22.5 6.5 19.0 69.5 34.1 BDL BDL
19.03.2015 7.1 20.5 8.1 25.1 7.6 20.9 64.2 28.1 BDL BDL
20.03.2015 6.3 19.6 8.8 22.8 6.7 19.9 72.8 33.6 BDL BDL
26.03.2015 5.9 21.0 7.7 23.5 6.3 21.4 69.2 29.4 BDL BDL
27.03.2015 6.5 18.3 7.0 25.1 7.0 18.8 73.5 35.1 BDL BDL
02.04.2015 6.0 17.9 8.6 21.0 6.5 18.2 65.6 32.6 BDL BDL
03.04.2015 7.1 20.5 7.1 22.6 7.4 20.9 72.9 29.5 BDL BDL
09.04.2015 6.7 19.0 8.6 23.4 7.1 19.5 67.4 31.7 BDL BDL
10.04.2015 6.0 19.6 7.5 24.9 6.4 19.9 65.9 33.4 BDL BDL
16.04.2015 5.9 18.2 8.2 25.0 6.2 18.6 69.5 32.2 BDL BDL
17.04.2015 6.5 19.5 9.0 21.0 6.9 19.9 71.3 35.1 BDL BDL
23.04.2015 6.7 20.3 7.4 22.6 7.2 20.7 73.2 33.6 BDL BDL
24.04.2015 6.1 18.2 7.8 24.6 6.5 18.6 68.5 29.4 BDL BDL
30.04.2015 6.6 21.2 7.3 22.8 6.9 21.6 66.4 28.3 BDL BDL
01.05.2015 7.0 17.8 8.9 24.7 7.4 18.3 64.9 31.8 BDL BDL
07.05.2015 6.3 20.3 7.5 25.1 6.8 20.7 67.3 33.6 BDL BDL
08.05.2015 6.7 22.0 8.6 21.4 6.9 22.5 70.2 35.0 BDL BDL
14.05.2015 6.9 18.4 7.9 22.8 7.3 18.9 68.6 29.4 BDL BDL
15.05.2015 7.3 19.6 8.0 23.4 7.8 20.0 65.4 32.3 BDL BDL
21.05.2015 6.9 20.7 7.6 24.7 7.3 21.3 71.5 34.9 BDL BDL
22.05.2015 7.2 18.6 7.4 23.6 7.7 18.9 73.3 33.8 BDL BDL
28.05.2015 5.9 19.7 8.3 22.4 6.3 20.2 69.8 30.4 BDL BDL
29.05.2015 6.8 20.4 9.0 21.3 7.3 24.9 71.2 29.5 BDL BDL
SO2 NO2 PM10 PM2.5
Max. 9.0 25.1 74.1 35.1
Min. 5.9 17.8 64.2 28.1
95%tile 8.8 25.0 73.5 35.1
98%tile 9.0 25.1 73.8 35.1
Page 394
A Note on Polluted River Stretches Identified by CPCB / MoEFCC in Rajasthan Region of India
Introduction
Central Pollution Control Board (CPCB) has established a network of monitoring locations on aquatic resources
across the country. For identification of the water bodies or their parts where water quality is at variance with
water quality criteria, it was felt important to measure water quality of that water body or its part.
Subsequently, through a wide network of water quality monitoring, water quality data are acquired. The data
thus obtained was analyzed statistically and compared with the water quality criteria with respect to BOD.
Criteria for Prioritization
The water quality data is analyzed and monitoring locations exceeding the water quality criteria are identified
as polluted locations with respect to risk. The degree of violation is w.r.t water quality criteria for drinking
water source with conventional treatment with respect to BOD. The polluted locations in a continuous
sequence are defined as Polluted River Stretches and categorized in five priority classes based on the
concentration of Biochemical Oxygen Demand (BOD) in mg/l as:
BOD level (mg/l.) Priority Class
Greater than 30 I
20 - 30 II
10 - 20 III
6 - 10 IV
3 - 6 V
Proposed Expansion of Integrated Cement Plant is located near Village: Ras, Tehsil: Jaitaran, District: Pali
(Rajasthan). Water Quality of rivers in Rajasthan is measured at 17 locations on 11 rivers and among them 14
locations is non-complying to the Water Quality Criteria mentioned above with respect to BOD. These 14
locations are on 8 rivers. The names of polluted rivers are Banas, Chambal, Chappi, Ghaggar, Kali Sindh,
Paravati, Jawai and Ujad. These eight rivers are identified under Priority classes as:
State Priority I Priority II Priority III Priority IV Priority V Total
Rajasthan 1 1 1 - 5 8
River (s) / Water Body within 10 km radius vicinity of the plant are:
1. Lilri River at an approx. distance of 2.0 km in North direction
2. Sukri River at an approx. distance of 8.0 Km in SSW direction
Lilri River is the main tributary of Guhiya River which originates in the hillocks near villages Khariyaniv and
Tharasani in Pali district and is not identified as polluted as per standards set by CPCB.
However, River Sukri comes into origin after confluence of Khari and Jawai River. Jawai River has been
identified as one of the eight Polluted Rivers, though the polluted stretch of the Jawai River as mentioned
below is falling at large distance from the project site.
Page 395
River Name Stretch identified BOD Range/
Max Value
Priority Towns identified
Jawai Jawai Dam Sena to
Galthani (approx. 10 Km of
Stretch)
3.4 V Sena, Galthani
The stretch of Jawai River is depicted below and does not fall within the vicinity of Proposed Expansion project
and is shown in figure given below:
Hence, it could be concluded that Plant site does not fall near to polluted stretch of River identified by the
CPCB / MoEFCC.
Reference:
a. “Monitoring of Indian National Aquatic Resources Series: MINARS/37 /2014-15” dated February 2015 of Central Pollution Control Board
(CPCB)
b. “Hydrology and Water Resources of India by Sharad K. Jain, Pushpendra K. Agarwal, Vijay”
Page 396
Form No. 19Prescribed Under Rule 14
(In respect of persons employed in occupations declared to be dangerous operations under section 87)
Name of Certifying Surgeon:
(1) Serial No.
(2) Deptt. & E.Code No. ~~.e~ p~ ']"'\ e.d/\,~~./\A,,()G-P
(3) Name of Employee M 'i'TND:J l.zo M~tl2...
(4) Sex : Male
«< (5) Age (on last birthday) 20 ~I'-:f'
(6) Date of employment on Present work: OS' NDv - UYD.3
(7) Date of leaving or transfer to other work:
(8) Reason of leaving transfer or other work:
(9) Name of job or occupation 1'1f' Q..~ '~oJ /~t:v
(10) Raw material or by product handled.
Investigations Result Normal Value
>- Blood Sugar:- {R} qQ. 6 70 -170 mg %
>- S. Cholesterol /30, ')- 130 -250 mg %
>- HDL Cholesterol l("2- r-: ')- 30 - 85 mg %
>- Triglyceride I l 6 r 8 30 - 150 mg %
>- LDL Up to 150mg%
>- VLDL Up to 50 mg %
>- URINE(R/M)
Blood Group: 0+-
Date: 3D I 0 I /2oC1,
~Signature of Employee
Mobile no. ~214~B2>Email ID: n\01"\o;'\<MY\DvL@)..5~ UcJ,{e1A,
Name of HOD: R' \< . B(2n~;6oJ.
Page 399
(11 ) Details of Medical Examination
(a) Pulse •.t~)~(b)
BP ~ Ii0~ """'"r;(c) RS '--N~
(d) CVS
(e) CNS
~j~(f) P/Abd.
Ht -- \1--0
Wt -- ::}-o
Cms (Without Shoe)
Kgs (With Clothes)BMI.. .'?.l:/.: b .
Chest - Full exp - '2J r Cms.
Full insp -:=:>0 Cms.
Abd -- :J 0 Cms.
Eye - R --
L-",;',,' ~
'(wlth'~lass I witb.OOtglass)
(g) Colour blindness :-
(h) Locomotor System:- ~~
(i) Spirometry Ear --
U) X-Ray
(k)
(I)
ECG
~.Smoker/N onsmoker
(m) Rig~nderiLeft Hander
(n) Height phobia e-r- J\1 ().--
(12) If suspended from work, State
Period of suspension with Detailed reasons.
(13) Re certified fit to resume duty on (with
Signature of certifying Surgeon)
(14) If certificate of Unfitness or suspension
Issued to worker.
(15) Signature with date of Certifying Surgeon.
Note: (1) Para (8) - Detailed summary of reasons for transfer or discharge should be stated.
(2) Para .(14) - Should be expressed as fit I unfit I suspended
I
Page 400
( I)
(2)
(3)
Ul )~
\)
(6)
) (7)
~8)
(9)
IMS/29/22/POIVII
Ed-O 1.ls·l.DT.27.0620 II
SI·IREE CEivlENT LTD, BANGUR crrv. Cement Plants including Power Plants
Form No. 19 (A)(Proscribed Under Rule 14)
(In J·~pec!..!!f...Pi~Qns_~I1'l.plol'edIn o~~l!.eJ~t!.2I1;SdeclAred to be ~.!rrH~~wol!.~o)2er$lt!ons updcr $~ctlo!!_.~21
I Nan1C:I·.C crti fy ing Surgeon • __ •._. .__ .. __. __ J
.,
Serial No.
Deptt, & E.Code Nu . p-M€ck(67P~)
rl"t fiNo.}' \CU\VI"RName of Employee
Sex fvlale
Age (on last birthday) "34- l(~
o 'C5-NOV- 2D 'O'C)Date of Joining
Date of leaving or transfer to other work:
R~ason of leaving transfer or other work:
Name ofjob or occupation MeCh~Y1~C~ V~ ~~~
'-:So\\a,{, ,-t-'\e.J~ \ r(10) Raw material or by product handled.
· ·-·--..·--·--·---· ·----·-----:--·---r--· · ·--· ·-·-_.Investivations Result Normal Value
.........._ __ __..b_ - ..-- ..- ..-.! "'-:c,' < '.' . -.... ...-- .»: Blood SLlgar:- {R} ! . '0"-- D 70··· 170 mg %..._-- - --. . --------t ..--..- -.--_ ..-- ---.--- ..-_ - - - _- -
:> Sv.Cholesterol ''2 ')..b' () 130 - 250 rng %---.------------_ ..---+-:> HDL Cholesterol .. --h.'G",. is .' 30 - 85 rng % .... .
- _-1--. __ - ---,- --.---.---.--------
:> Triglyceride .....__ ' ..yq.:_~ 30 -.150 mg %
.=~~t~E(~M)··-!···'~~t--t .....~tfo?_~!~-~_=~J-
oBlood Group:
Date: \b I!, 1201'
~Signature of Employee
Mobile no. <4<...1 Lt3?6~ B~E.m ail I~: mC\V\oi'(}.A~SWtu~~~
Name of HOD: R01/Y\ Ku ~ .
.. Page 401
(11) Details of Medical Examination"
(8) Pulse 1< ) iI11!--
(b) BP' 11£ , 73
(c) RS~· ~
(d) CV~ _. ~&~
.Ht·· 'Tl.----.Cms (Without Sh()~)
Wt .~ 7 'l.- Kgs (With Clothes)
Chest- Full exp - 9 t ems.
Fullinsp - ~ ~ ems.
BMI .. " .
(g)
(h)
Colour blindness •. 1.;5}~+'vu..Locomotor System :- ~ .
~CJ ems.
R·- ~ IiL·- ('/~ V--
(with glass / without glass)
(e) CN~:; - vvv-VV) Abel --
CO P/Aod. _ \'V\.-:D Eye -·1
)J
(i) Sj irornetry Ear -- R- /0L-
U) X'RayI
r
(k) E(G
(I) History of .Addiction (I f any):- Smoking / Tobacco / Gurkha / any otlrcr fJJj
Ir
(m)
(n) I- eight phobia
( 12)
(0) Past / Family illness (Ifany) :- Diabetes / Hypertension / Epilepsy / any otherI· .
II
If suspended from work, State
Period 'of suspension with Dctai led reasons.
Re cer:.jfied fit to resume duty on (with
Signatrre of certifying Surgeon)
If certificate of Unfitness or suspension
lssuedto worker.
Signatjure with date of Certifying Suraeon./1 . ~
I.
r
(14)
( 15)
r.
(i3)
-------------------~------------------~------------~---------
Note; ( I) Para (8) Detailed sununarv of reasons for transfer or discharge should be sl;lled
(2) Parol ( I·~) Sholiid he r_'\pl,:~\t!d as lit j unfit suspended
.. Page 402
I MS/29/22/FORI I 2
Ed-O I ,Is-l ,OT.27.06.20 13
SHREECEMENTLTD, BANGURCITY »>:
Cement Plants including Power Plants ~
Form No. 19 (B)(Prescribed Under Rule 14)
(In respect of persons employed in occupations declared to be dangerous operations under section 87)
, [Ban~~_()fCeliifying Surgeon: Dr. Rak,esh Sharma ...- ..._J
I) Serial No.:- 2) Date:~ It...'42-0(7
:; ~:::a::o:ork:, -~-~:~--~~S/O ~ __~ ~ __~ _
5) Sex
7) Date of employment on present work: Q,.lYO::J
8) Date of leav ing or transfer to other work :wJI9) Nature of job or occupation : '
10) Raw material or by product handled .
Male 6) Age: yrs
1 I) Details of Medical Exarnination ;
12) Job Locationr-
a) Height : !~ ems b) Wt: 6 )J(gs BM] :
!\ ~h.>
c) Hb (Pallor) : Gm% d) Jaundice (Icterus) : Yes / No
e) Ear : Rt 0Y Lt(o/ f) Eye: Rt Ct'6 Lt Mj;
g) CYS ~ h) BP : J 1;-1fSI y- mmHg
i) Resp : ~() ml vi j) Locomotor / Other;- ~
k) Colour Blindness- YeslNo 1) Mo.No.:
IV\)l.s) Past/Personal/Familyjjistory of: Diabetes/ Hypertension/ Epilepsy! TB. / Asthma / Addiction, ..
14) Additional investigations (if any) :
15) Remarks/ Advice:
16) ]fsuspendedfrom work, State Period of suspension with Detailed reasons:
17) Re certified fit to resume duty on (with Signature of certifying Surgeon) !/f'V'O'
18) if certificate of Unfitness or suspension issued to worker:
19) Signature with date of Certifying Surgeon:. ~~.
(S' {If if . )''ignature 0 . certi 'ylng surgeon
I
Page 403
IMS/29/22/FORII 2
Ed-O 1,Is· 1,DT.27.06.20 13
SHREE CEMENT LTD, BANGUR CITYCement Plants including Power Plants
Form No. 19 (B)(Prescribed Under Rule 14)
(In respect of persons employed in occupations declared to be dangerous operations under section 87)
-I
Name of Certi in Sur eon: Dr. Rakesh.Sl;a_r_m_a ~
c.~ ~ ~.l61) Serial No.:-. ~ d/Y7 ~ 2) Date:s r rs 1201-(
3) Contractor:-, r: ~ at,.1.J'4) Name of Worker ... -~l19!~-s/o ---------~--------------'il1J-----
5) Sex Male 6) Age: .. ~ ..2-..yrs
7) Date of employment on present work:
8) Date of leaving or transfer to other work:
9) Nature of job or occupation: A-~ PM,10) Raw material or by product handled
11) Details of Medical Examination:
12)Job Location'-
a) Height:' T-:)cms
c) Hb (Pallor): ,~~, Gm%
e) Ear : Rt tD Lt @g) CVS : ~.~ 'Si) Resp : u..'SO ml /
k) Colour Blindness-Yes~
b) Wt:~ Kgs
d) Jaundice (Icterus) :
f) Eye: Rt ~} ~ Lt c J ~
h) BP :,z.l-; ~~ mmHg ,
j) Locomotor / Other ;- ~
I) Mo.No.: Cf 0 ~ cr ( f \) G s'-
BM! :
Yes/N~
13) Past/Personal/Family history of: Dia~tes/ Hypertension/ Epilepsy / T.B. / Asthma / Addiction ... _~ .
14) Additional investigations (if any) :
15) Remarks / Advice:
16) If suspended from work, State Period of suspension with Detailed reasons: r~17) Re certified fit to resume duty on (with Signature of certifying Surgeon)
18) If certificate of Unfitness or suspension issued to worker:
19) Signature with date of Certifying Surgeon:
~~,.t'{f~(Signat - of work man) (Signature of certifying surgeon)
r Page 404
,hffiSHREE CEMENT LIMITED
BANGUR NAGAR, BEAWAR, RAJASTHAN
ENVIRONMENT POLICY
,/ Efficient use of natural resources, energy, plant & equipment.
'/ Reduction in emissions, noise, waste and greenhouse gases.
,/ Promotion to reuse and recycling wastes.
'/ Continual improvement in environment management with proper systems to
prevent, mitigate and control environmental impacts due to operations across
the value chain and in local community.
Building awareness amongst all stakeholders including employees,
customers, vendors etc. on environmental issues.
C omp liance o f relevant environmental legi slations.
Signature
Ramakant Sharrtr Director
Date: 30th June 2015
Page 405
"*\
ENVIRONMENT MAIIAGEMENT SYSTEM
1. LEGAL & OTHER REQUIREMENTS
a. We have established and maintained a procedure to identiff, access and
update legal and other requirements to which we subscribe, that are
applicable to the environmental aspects/ impacts and Occupational Healthand Safety Hazards (OHS) / Risks of our products, activities and servicesrespectively. The list of legal and other requirements applicable to ouroperations are maintained separately and are communicated to ourstakeholders. Main legal requirements are as follows:
,/ Environmental acts & rules,/ Mines acts & rules./ Factory acts & rules,/ Boiler acts & rules
2. OPERATIONAL CONTROL PROCEDURES
We have identified our operations and activities that are associated withEnvironmental aspects and OHS risks in line with our EnvironmentalPolicy. We plan these activities, including maintenance in order to ensurethey are carried out under specified conditions by:
'/ Establishing and maintaining SOPs to check out the deviations fromEMS.
'/ These procedures define the criteria to ensure that activities areperformed under specified conditions, complying to legal and otherrequirements also:
o Communication of SOPs related to significant environmental aspects/ OH&S risk of operations, goods, equipment and services purchasedandlor used, to our stakeholders.
' To rpduce Environment Impact / OH&S Hazard,with the applicationof SOPs considering their adaptati.on to the human capabilities byproper designing of work place, process and to take precaution whileinstallation of machinery.
,tr$ixsr
.l
t WPage 406
I
a
l
,tr$jltsro To review Control Measures and SOPs on regular intervals,
effectiveneSSandtobringinchangesthatareidentified&neceSSaryto implement.
i
b. Relevant Operation Control Measures
'/ Limestone mines operation- Water sprinkling on the haulage roadwhile transporting the limestone, use of enclosed belt .oru.yors forraw material transportation and emission control at transfer points.
'/ Clinkerization- Storage of raw meal, petcoke and clinker in silos;using ESPs and bag houses/ bag filters and clinker bulk loading.
'/ cement Grinding & Packing- cyclones, Bag Filters, ny ashhandling, automatic bag filing machines, using conveyor belts fortransportation of bags, use of tarpaulin in the truck transportation andwagon loading.
'/ Storage in yard- Proper preservation by covering tarpaulin shed etc.. '/ Utitity operation- Murrug.ment of waste/used oit, oily wastes and
waste water management.
'/ General- Dust control by good housekeeping & maintenance, use ofdust "extraction and recycling systems to remove dust from workareas, contractor activities and task observations.
'/ use of proper personal protective equipment (ppE).
3. ROLES & RESPONSIBILITIES
We have established, implemented and maintained EMS to meet itsrequirements at all of our locations within the organizational boundaries.Roles and responsibilities of various personnel, who manage, perform andverift the activities and their impacts on environment and,/or OH&S havebeen defined by the top management.
a- President (Works)- President (Works) will review and ensure theimplementation of EMS related activities as per the schedules & SOPs.He will coillmunicate with the board of directors on all issues related toEMS.
b. Unit ffeaAs- Unit Heads will ensure and review the implementation ofEMS at regular intervals and provide all required resources to the
8'
I
)na'"
Page 407
thtjr"="timplementation team. They will report the progress of EMS to the
President (Works).
c. Vice President (Environment)- He will ensure all the compliances as
per environment legislation. He'll report to President (Works) about the
new legislative requirements and ensure proper implementation of EMS.
EMS Implementation Team- It'll be comprising of multi-disciplinaryprofessionals from all departments who'll coordinate with EMSImplementation Team and layout the implementations regarding EMS on the
floor. The team will be responsible for all the activities and fulfillment ofrequirements of EMS and shall also be authoized and responsible for:
'/ Coordinate with all unit heads for EMS at respective locations.
'/ Implementation of EMS by establishment & maintenance of itsrequirements aligning with environment policy.
'/ Arrangement of all necessary resources to operate the management
system as per the SOPs.
'/ Ensure the review of the system at regular intervals
'/ Reporting of EMS performance to unit heads and V.P.
Environment for further actions for improvement.
ORGANIZATIONAL STRUCUTRE
President (Works)
EMS Implementation Team
Board of Directors
Vice - President (Env.) Unit Heads
qil*.t fr,ry
Page 408
!
!-
I
ttltJx""*I
I
4. COMMUNICATION
a. Communication with Board of Directors
President (Works) is responsible to communicate the issues related to EMS
and non-conformance of the system, to the top management including board
of directors.
b. Internal Communication
It should be ensured by the top management that appropriate internal
communication are established and maintained within the organization.
Communication can be made any of the means like verbal & wriuen or may
be through fax, intranet, e-mails, notice boards etc.
c. Participation and consultation
Top management must ensure consultation with the employees and
workers, over changes in work place such as introduction of new &modified equipment, materials etc.
All employees and workers are to be involved and represented indevelopment, implementation and review of EMS policy, itsobjectives and decisions on implementation of SOPs to manage &control environmental aspects and OH&S risks as per the mode and
nature of activity and incident I accident investigations..
'/ Contractors shall be consulted wherever the changes affect theirOH&S.
d. Bxternal Communication
EMS coordinator is responsible for receiving, documentation and respond tothe communications from external parties to review their concerns/
suggestions and dealing with public authorities for emergency preparedness
and other relevant issues shall be conducted.
W
t-I
I
Page 409
By Speed Post
'"
'.~. . "" \.,' ~ :.-' ~...;','~;~~',.,.• . l'-{fl ~~r,i:' .::~~.~~~
. No. J-11015/226/2015-IA.II (M) .
,.il'. Government of India
',M'I-1ifstryof Environment, Forest & Climate Change
Impact Assessment Division
***Indira Paryavaran Bhavan,
Vayu Wing, 3rd
Floor, Aliganj,
Jor Bagh Road, New Delhi-110 003
Dated: 11th August, 2015
To
/ M/ s Shree Cement Ltd.Bangur Nagar, Post Box No. 33,
Beawar - 305 901 Rajasthan
Tel. No. 01462 - 228101-6; Fax: 01462228117/228119
Email: [email protected]
Sub.:- Enhancement of Limestone production in Captive Limestone mine from
19.6 million TPA to 25.3 million TPA (ROM) of limestone by M/s Shree
Cement Ltd., located at village (s)-Nimbeti and Jawangarh, Tehsil-
Jaitaran, District-Pali, Rajasthan (750ha)-TOR regarding.
Ref:- Online proposal no. IA/RJ/MIN/27659/2015.
Sir,
This has reference to above mentioned proposal for determining the Terms of
Reference (TOR) for undertaking detailed EIA study for the purpose of obtaining
environmental clearance in accordance with the provisions of the EIA Notification,
2006. For this purpose, the Proponent had submitted information in the prescribed
format (Form-1) along with a Pre-feasibility Report. The proposal was considered by
the Reconstituted Expert Appraisal Committee in its 35th meeting held during June
24th-26th, 2015.
2. The existing mine lease area is 750 ha. Mining Lease was granted wide letter
no. P-3(65/ Khan/Group-1/91 dated 06.08.1996 and Mining Operation was started on
13 June 1997. The mining method is open cast Mechanized with maximum bench
height of 12 m and minimum bench width of 20 m. Controlled blasting, wet drilling/dry
drilling with dust collector, high capacity HEMM, crushing and haulage are being/ will
be practiced. Ultimate pit slope is proposed to be kept at 45°. Over burden and inter
burden is being stacked/will be stacked at earmarked area(s) and backfilled in worked
out pit. Water spray in crusher is being/ will be practiced. Controlled blasting using
shock tube detonator is being /wlll be used. Rock breaker is being /wtll be used in
place of secondary blasting. The haul roads are being /will be kept wide to support
two-way traffic and properly maintained by road compactor and regular water
spraying. Garland drains and de-silting pit are made all around the OB dumps. Waste
water generated from office toilets is being disposed through soak pit via septic tank.
Work shop discharge is being used for dust suppression after removal of oil and
grease. The total waste generation in Quarry would be 302.0 million tones. Waste
Page 1 of8
Page 422
disposal is being done by end tipping method and will be continued in future also while
forming terraces of 12m in height.
3. The capital cost of expansion of mines would be Rs. 2530 Lakhs. Existing water
consumption is 380 and after proposed expansion, it will be 500 KLD, which will be
sourced from the groundwater and rain water collected in mine pit. Permission for
withdrawal of ground water for plant, mines & colony has already been granted by
CGWA vide letter no. 21-4(12)/ WR/ CGWA/ 2005- 616 dated 23rd May, 2011, 21-
4(12)/ WR/ CGWA/ 2005-1220 dated 12th July, 2013 and 21-4(12 -B)/ WR/ CGWA/
2005- 255 dated 11th February, 2014. There is no National Park, Wildlife Sanctuary,
Biosphere Reserve, Wildlife corridors, Tiger/Elephant Reserves etc. within 10 km radius
of the mine site. There are 2 Reserved (approx 8.3 km in West direction and approx
9.7 km in SE direction) respectively and 1 protected forest (approx 3.5 km in SSE
direction) within the 10 km radius from mine site.
4. The Project Proponent mentioned that they had collected base line data since
Maa:!L2D15 ann requested to-use the baseline.data.of pre-monsoon season i.e. March-
2015 - May 2015. The Committee deliberated the issues and based on the request
made by the Project Proponent w.r.t. collection of base line data, the Committee
agreed for the same.
5. Based on the information content in the documents submitted and the
presentation made before the Committee for mining projects, the following TOR are
prescribed for undertaking detailed EIA study:-
1) Year-wise production details since 1994 should be given, clearly stating the
highest production achieved in anyone year prior to 1994. It may also be
categorically informed whether there had been any increase in production after
the EIA Notification 1994 came into force, w.r.t. the highest production
achieved prior to 1994.
2) A copy of the document in support of the fact that the Proponent is the rightful
lessee of the mine should be given.
3) All documents including approved mine plan, EIA and Public Hearing should be
compatible with one another in terms of the mine lease area, production levels,
waste generation and its management, mining technology etc. and should be
in the name of the lessee.
4) All corner coordinates of the mine lease area, superimposed on a High
Resolution Imaqerv/toposheet, topographic sheet, geomorphology and geology
of the area should be provided. Such an Imagery of the proposed area should
clearly show the land use and other ecological features of the study area (coreand buffer zone).
5) Information should be provided in Survey of India Toposheet in 1:50,000 scale
indicating geological map of the area, geomorphology of land forms of the
area, existing minerals and mining history of the area, important water bodies,
streams and rivers and soil characteristics.
6) Details about the land proposed for mining activities should be given with
information as to whether mining conforms to the land use policy of the State;
Page 2 of S
Page 423
land diversion for mining should have approval from State land use board or
the concerned authority.
7) It should be clearly stated whether the proponent Company has a well laid
down Environment Policy approved by its Board of Directors? If so, it may be
spelt out in the EIA Report with description of the prescribed operating
process/procedures to bring into focus any infringementjdeviationjviolation of
the environmental or forest norms/ conditions? The hierarchical system or
administrative order of the Company to deal with the environmental issues and
for ensuring compliance with the EC conditions may also be given. The system
of reporting of non-compliances / violations of environmental norms to the
Board of Directors of the Company and/or shareholders or stakeholders at
large, may also be detailed in the EIA Report.
8) Issues relating to Mine Safety, including subsidence study in case of
underground mining and slope study in case of open cast mining, blasting
study etc. should be detailed. The proposed safeguard measures in each case
should also be provided.
9) The study rea will comprise of 10 km zone around the mine lease from lease
periphery and the data contained in the EIA such as waste generation etc.
should be for the life of the mine / lease period.
10) Land use of the study area delineating forest area, agricultural land, grazing
land, wildlife sanctuary, national park, migratory routes of fauna, water bodies,
human settlements and other ecological features should be indicated. Land use
plan of the mine lease area should be prepared to encompass preoperational,
operational and post operational phases and submitted. Impact, if any, of
change of land use should be given.
11) Details of the land for any Over Burden Dumps outside the mine lease, such as
extent of land area, distance from mine lease, its land use, R&R issues, if any,
should be given.
12) A Certificate from the Competent Authority in the State Forest Department
should be provided, confirming the involvement of forest land, if any, in the
project area. In the event of any contrary claim by the Project Proponent
regarding the status of forests, the site may be inspected by the State Forest
Department along with the Regional Office of the Ministry to ascertain the
status of forests, based on which, the Certificate in this regard as mentioned
above be issued. In all such cases, it would be desirable for representative of
the State Forest Department to assist the Expert Appraisal Committees.
13) Status of forestry clearance for the broken up area and virgin forestland
involved in the Project including deposition of net present value (NPV) and
compensatory' afforestation (CA) should be indicated. A copy of the forestry
clearance should also be furnished.
14) Implementation status of recognition of forest rights under the Scheduled
Tribes and other Traditional Forest Dwellers (Recognition of Forest Rights) Act,
2006 should be indicated.
Page 3 of8
Page 424
15) The vegetation in the RF / PF areas in the study area, with necessary details,
should be given.
16) A study shall be got done to ascertain the impact of the Mining Project on
wildlife of the study area and details furnished. Impact of the project on the
wildlife in the surrounding and any other protected area and accordingly,
detailed mitigative measures required, should be worked out with cost
implications and submitted.
17) Location of National Parks, Sanctuaries, Biosphere Reserves, Wildlife Corridors,
Ramsar site Tiger/Elephant Reserves/(existing as well as proposed), if any,
within 10 km of the mine lease should be clearly indicated, supported by a
location map duly authenticated by Chief Wildlife Warden. Necessary clearance,
as may be applicable to such projects due to proximity of the ecologically
sensitive areas as mentioned above, should be obtained from the Standing
Committee of National Board of Wildlife and copy furnished.
18) A detailed biological study of the study area [core zone and buffer zone (10 km
radius of the periphery of the mine lease)] shall be carried out. Details of flora
and fauna, endangered, endemic and RET Species duly authenticated,
separately for core and buffer zone should be furnished based on such primary
field survey, clearly indicating the Schedule of the fauna present. In case of
any scheduled-I fauna found in the study area, the necessary plan alongwith
budgetary provisions for their conservation should be prepared in consultation
with State Forest and Wildlife Department and details furnished. Necessary
allocation of funds for implementing the same should be made as part of the
project cost.
19) Proximity to Areas declared as 'Critically Polluted' or the Project areas likely to
come under the 'Aravali Range', (attracting court restrictions for mining
operations), should also be indicated and where so required, clearance
certifications from the prescribed Authorities, such as the SPCBor State Mining
Dept. Should be secured and furnished to the effect that the proposed mining
activities could be considered.
20) Similarly, for coastal Projects, A CRZ map duly authenticated by one of the
authorized agencies demarcating LTL. HTL, CRZ area, location of the mine
lease w.r.t CRZ, coastal features such as mangroves, if an should beftJrnished: (Note: The Mining-Projects railing under CRZ Would also need to
obtain approval of the concerned Coastal Zone Management Authority).
21) R&R Plan/compensation details for the Project Affected People (PAP) should be
furnished. While preparing the R&R Plan, the relevant State/National
Rehabilitation & Resettlement Policy should be kept in view. In respect of SCs
/STs and other weaker sections of the society in the study area, a need based
sample survey, family-wise, should be undertaken to assess their
requirements, and action programmes prepared and submitted accordingly,
integrating the sectoral programmes of line departments of the State
Government. It may be clearly brought out whether the village(s) located in
the mine lease area will be shifted or not. The issues relating to shifting of
village(s) including their R&R and socio-economic aspects should be discussedin the Report.
Page 4 of'S
Page 425
(
22) One season (non-monsoon) [i.e. March - May (Summer Season); October -
December (post monsoon season) ; December - February (winter season)]
primary baseline data on ambient air quality as per CPCB Notification of 2009,
water quality, noise level, soil and flora and fauna shall be collected and the
AAQ and other data so compiled presented date-wise in the EIA and EMP
Report. Site-specific meteorological data should also be collected. The location
of the monitoring stations should be such as to represent whole of the study
area and justified keeping in view the pre-dominant downwind direction and
location of sensitive receptors. There should be at least one monitoring station
within 500 m of the mine lease in the pre-dominant downwind direction. The
mineralogical composition of PMlO, particularly for free silica, should be given.
23) Air quality modeling should be carried out for prediction of impact of the
project on the air quality of the area. It should also take into account the
impact of movement of vehicles for transportation of mineral. The details of the
model used and input parameters used for modeling should be provided. The
air quality contours may be shown on a location map clearly indicating the
location of the site, location of sensitive receptors, if any, and the habitation.
The wind roses showing pre-dominant wind direction may also be indicated on
the map.
24) The water requirement for the Project, its availability and source should be
furnished. A detailed water balance should also be provided. Fresh water
requirement for the Project should be indicated.
25) Necessary clearance from the Competent Authority for drawl of requisite
quantity of water for the Project should be provided.
26) Description of water conservation measures proposed to be adopted in the
Project should be given. Details of rainwater harvesting proposed in the
Project, if any, should be provided.
27) Impact of the Project on the water quality, both surface and groundwater,
should be assessed and necessary safeguard measures, if any required, should
be provided.
28) Based on actual monitored data, it may clearly be shown whether working will
intersect groundwater. Necessary data and documentation in this regard may
be provided. In case the working will intersect groundwater table, a detailed
Hydro Geological Study should be undertaken and Report furnished. The
Report inter-alia, shall include details of the aquifers present and impact of
mining activities on these aquifers. Necessary permission from Central Ground
Water Authority for working below ground water and for pumping of ground
water should also be obtained and copy furnished.
29) Details of any stream, seasonal or otherwise, passing through the lease area
and modification / diversion proposed, if any, and the impact of the same on
the hydrology should be brought out.
Page 5 of8
Page 426
30) Information on site elevation, working depth, groundwater table etc. Should be
provided both in AMSL and bgl. A schematic diagram may also be provided for
the same.
31) A time bound Progressive Greenbelt Development Plan shall be prepared in a
tabular form (indicating the linear and quantitative coverage, plant species and
time frame) and submitted, keeping in mind, the same will have to be
executed up front on commencement of the Project. Phase-wise plan of
plantation and compensatory afforestation should be charted clearly indicating
the area to be covered under plantation and the species to be planted. The
details of plantation already done should be given. The plant species selected
for green belt should have greater ecological value and should be of good
utility value to the local population with emphasis on local and native species
and the species which are tolerant to pollution.
32) Impact on local transport infrastructure due to the Project should be indicated.
Projected increase in truck traffic as a result ef the- Project in the present road
network (including those outside the Project area) should be worked out,
indicating whether it is capable of handling the incremental load. Arrangement
for improving the infrastructure, if contemplated (including action to be taken
by other agencies such as State Government) should be covered. Project
Proponent shall conduct Impact of Transportation study as per Indian Road
Congress Guidelines.
33) Details of the onsite shelter and facilities to be provided to the mine workers
should be included in the EIA Report.
34) Conceptual post mining land use and Reclamation and Restoration of mined out
areas (with plans and with adequate number of sections) should be given in
the EIA report.
35) Occupational Health impacts of the Project should be anticipated and the
proposed preventive measures spelt out in detail. Details of pre-placement:
medical examination and periodical medical examination schedules should be
incorporated in the EMP. The project specific occupational health mitigation
measures with required facilities proposed in the mining area may be detailed.
36) Public health implications of the Project and related activities for the population
in the impact zone should be systematically evaluated and the proposed
remedial measures should be detailed along with budgetary allocations.
37) Measures of socio economic significance and influence to the local community
proposed to be provided by the Project Proponent should be indicated. As far
as possible, quantitative dimensions may be given with time frames for
implementation.
38) Detailed environmental management plan (EMP) to mitigate the environmental
impacts which, should inter-alia include the impacts of change of land use, loss
of agricultural and grazing land, if any, occupational health impacts besides
other impacts specific to the proposed Project.
Page 6 of8
Page 427
"
39) Public Hearing points raised and commitment of the Project Proponent on the
same along with time bound Action Plan with budgetary provisions to
implement the same should be provided and also incorporated in the final
EIA/EMP Report of the Project.
40) Details of litigation pending against the project, if any, with direction /order
passed by any Court of Law against the Project should be given.
41) The cost of the Project (capital cost and recurring cost) as well as the cost
towards implementation of EMP should be clearly spelt out.
42) A Disaster management Plan shall be prepared and included in the EIA/EMP
Report.
43) Benefits of the Project if the Project is implemented should be spelt out. The
benefits of the Project shall clearly indicate environmental, social, economic,
employment potential, etc.
44) Piezometer time series data.
45) Status of compliance of earlier EC and status of Action Plan on the issues
raised during earlier Public Hearing.
46) Green belt development status.
6. Besides the above, the below mentioned general points are also to be
followed: -
a) All documents to be properly referenced with index and continuous page
numbering.
b) Where data are presented in the Report especially in Tables, the period in
which the data were collected and the sources should be indicated.
c) Project Proponent shall enclose all the analysis/testing reports of water, air,
soil, noise etc. using the MoEF&CC/NABL accredited laboratories. All the
original analysis/testing reports should be available during appraisal of the
Project.
d) Where the documents provided are in a language other than English, an
English translation should be provided.
e) The Questionnaire for environmental appraisal of mining projects as devised
earlier by the Ministry shall also be filled and submitted.
f) While preparing the EIA report, the instructions for the Proponents and
instructions for the Consultants issued by MoEF vide a.M. No. J-
11013/41/2006-IA.II(I) dated 4th August, 2009, which are available on the
website of this Ministry, should be followed.
g) Changes, if any made in the basic scope and project parameters (as submitted
in Form-I and the PFR for securing the TOR) should be brought to the attention
of MoEF&CC with reasons for such changes and permission should be sought,
as the TOR may also have to be altered. Post Public Hearing changes in
structure and content of the draft EIA/EMP (other than modifications arising
out of the P.H. process) will entail conducting the PH again with the revised
documentation.
Page 7 of8
Page 428
h) As per the circular no. J-11011/618/2010-IA.II(I) dated 30.5.2012, certified
report of the status of compliance of the conditions stipulated in the
environment clearance for the existing operations of the project, should be
obtained from the Regional Office of Ministry of Environment, Forest and
Climate Change, as may be applicable.
i) The EIA report should also include (i) surface plan of the area indicating
contours of main topographic features, drainage and mining area, (ii)
geological maps and sections and (iii) sections of the mine pit and external
dumps, if any, clearly showing the land features of the adjoining area.
7. The EIA report should also include (i) surface plan of the area indicating
contours of main topographic features, drainage and mining area, (ii) geological maps
and sections and (iii) sections of the mine pit and external dumps, if any, clearly
showing the land features of the adjoining area.
8. The prescribed TORs would be valid for a period of three years for submission of
the EIA/EMP reports, as per the O.M. No. J-11013/41/2006-IA.II(I) dated 22.3.2010,
22.08.2014, 08.10.2014 and 07.11.2014.
9. After preparing the draft EIA (as per the generic structure prescribed in
Appendix- III of the EIA Notification, 2006) covering the above mentioned issues, the
proponent will get the public hearing conducted and take further necessary action for
obtaining environmental clearance in accordance with the procedure prescribed under
the EIA Notification, 2006.
. YOUr faithfully,
~ ~~'-~
(Dr. U. Sridharan)
Director (S)
Copy to:
1). The Secretary, Ministry of Mines, Government of India, Shastri Bhawan, New
Delhi
2). The Secretary, Department of Mines & Geology, Government of Rajasthan
Secretariat, Jaipur.
3). The Secretary, Department of Environment, Government of Rajasthan,
Secretariat, Jaipur.
4). The Secretary, Department of Forest, Government of Rajasthan, Secretariat,
Jaipur. -
5). The Additional Principal Chief Conservator of Forests, Ministry of
Environment, Forest and Climate Change, Regional Office (CZ), Kendriya
Bhawan, s= Floor, Sector "H", Aliganj, Lucknow - 226020.
6). The Member Secretary, Rajasthan State Pollution Control Board, 4,
Institutional area, Jhalana, Doongri, Jaipur.
7). The Controller General, Indian Bureau of Mines, Indira Bhavan, Civil Lines,
Nagpur - 440 001
8). The District Collector, Pali District, State of Rajasthan.
9). Guard File. /'10). MoEFwebsite.
(Dr. U. Sridharan)
Director (S)
Page 8 of8
\ <
J
Page 429
Solid Sample Analysis
Test Report No. : 15/04/2016Issue DateEK0/EV-SL/112/090416
TEST REPORT
Sample Description
Sample Received on
09/04/2016 To 15/04/2016
RESULTS
09/04/2016
500 gmSample Quantity
Shree Cement Limited
Bangaur City
P.O RAS- 306107
Tehsil- Jaitaram
Issued To
Distt- Pali (Rajasthan)
Analysis Duration
SOP-S/50
Sample Drawn on 08/04/2016
Coal
EPEPL(Mr. Harish Kumar)Sample Drawn by
Sampling Plan & Procedure
NormalEnvironmental Condition
Remark (if any) NA
NASampling Location
PARAMETERS.No. Results UnitsTest Methods
Chromium Total (as Cr)1 4.55 mg/kgICP - MS
Lead (as Pb)2 4.88 mg/kgICP - MS
Mercury (as Hg)3 0.09 mg/kgICP - MS
Arsenic (as As)4 0.18 mg/kgICP - MS
Notes :
1. The results given above are ralated to the tested sample, as received & mentioned parameters.
The customer asked for the above tests only.
2. This test report will not be generated again, either wholly or in part, without written permission of the Laboratory.
3. This test report will not be use for any publicity/legal purpose.
4. This test samples will be disposed off after two weeks from the date of issue of test report, unless until specified by the customer.
Sample received for biological tests will be destroyed after 7 days from the date of issue of test report.
5. Responsibility of the Laboratory is limited to the invoiced amount only.
**End of Report**
Authorized Signatory
For EKO PRO ENGINEERS PVT. LTD
Page No. 1/1Page 430
Solid Sample Analysis
Test Report No. : 15/04/2016Issue DateEK0/EV-SL/113/090416
TEST REPORT
Sample Description
Sample Received on
09/04/2016 To 15/04/2016
RESULTS
09/04/2016
500 gmSample Quantity
Shree Cement Limited
Bangaur City
P.O RAS- 306107
Tehsil- Jaitaram
Issued To
Distt- Pali (Rajasthan)
Analysis Duration
SOP-S/50
Sample Drawn on 08/04/2016
Pet Coke
EPEPL(Mr. Harish Kumar)Sample Drawn by
Sampling Plan & Procedure
NormalEnvironmental Condition
Remark (if any) NA
NASampling Location
PARAMETERS.No. Results UnitsTest Methods
Chromium Total (as Cr)1 6.25 mg/kgICP - MS
Lead (as Pb)2 4.12 mg/kgICP - MS
Mercury (as Hg)3 0.12 mg/kgICP - MS
Arsenic (as As)4 0.32 mg/kgICP - MS
Notes :
1. The results given above are ralated to the tested sample, as received & mentioned parameters.
The customer asked for the above tests only.
2. This test report will not be generated again, either wholly or in part, without written permission of the Laboratory.
3. This test report will not be use for any publicity/legal purpose.
4. This test samples will be disposed off after two weeks from the date of issue of test report, unless until specified by the customer.
Sample received for biological tests will be destroyed after 7 days from the date of issue of test report.
5. Responsibility of the Laboratory is limited to the invoiced amount only.
**End of Report**
Authorized Signatory
For EKO PRO ENGINEERS PVT. LTD
Page No. 1/1Page 431
Solid Sample Analysis
Test Report No. : 15/04/2016Issue DateEK0/EV-SL/110/090416
TEST REPORT
Sample Description
Sample Received on
09/04/2016 To 15/04/2016
RESULTS
09/04/2016
500 gmSample Quantity
Shree Cement Limited
Bangaur City
P.O RAS- 306107
Tehsil- Jaitaram
Issued To
Distt- Pali (Rajasthan)
Analysis Duration
SOP-S/50
Sample Drawn on 08/04/2016
Laterite
EPEPL(Mr. Harish Kumar)Sample Drawn by
Sampling Plan & Procedure
NormalEnvironmental Condition
Remark (if any) NA
NASampling Location
PARAMETERS.No. Results UnitsTest Methods
Chromium Total (as Cr)1 5.12 mg/kgICP - MS
Lead (as Pb)2 1.63 mg/kgICP - MS
Mercury (as Hg)3 0.16 mg/kgICP - MS
Arsenic (as As)4 0.27 mg/kgICP - MS
Notes :
1. The results given above are ralated to the tested sample, as received & mentioned parameters.
The customer asked for the above tests only.
2. This test report will not be generated again, either wholly or in part, without written permission of the Laboratory.
3. This test report will not be use for any publicity/legal purpose.
4. This test samples will be disposed off after two weeks from the date of issue of test report, unless until specified by the customer.
Sample received for biological tests will be destroyed after 7 days from the date of issue of test report.
5. Responsibility of the Laboratory is limited to the invoiced amount only.
**End of Report**
Authorized Signatory
For EKO PRO ENGINEERS PVT. LTD
Page No. 1/1Page 432
Solid Sample Analysis
Test Report No. : 15/04/2016Issue DateEK0/EV-SL/114/090416
TEST REPORT
Sample Description
Sample Received on
09/04/2016 To 15/04/2016
RESULTS
09/04/2016
500 gmSample Quantity
Shree Cement Limited
Bangaur City
P.O RAS- 306107
Tehsil- Jaitaram
Issued To
Distt- Pali (Rajasthan)
Analysis Duration
SOP-S/50
Sample Drawn on 08/04/2016
Gypsum
EPEPL(Mr. Harish Kumar)Sample Drawn by
Sampling Plan & Procedure
NormalEnvironmental Condition
Remark (if any) NA
NASampling Location
PARAMETERS.No. Results UnitsTest Methods
Chromium Total (as Cr)1 3.11 mg/kgICP - MS
Lead (as Pb)2 1.48 mg/kgICP - MS
Mercury (as Hg)3 0.08 mg/kgICP - MS
Arsenic (as As)4 0.13 mg/kgICP - MS
Notes :
1. The results given above are ralated to the tested sample, as received & mentioned parameters.
The customer asked for the above tests only.
2. This test report will not be generated again, either wholly or in part, without written permission of the Laboratory.
3. This test report will not be use for any publicity/legal purpose.
4. This test samples will be disposed off after two weeks from the date of issue of test report, unless until specified by the customer.
Sample received for biological tests will be destroyed after 7 days from the date of issue of test report.
5. Responsibility of the Laboratory is limited to the invoiced amount only.
**End of Report**
Authorized Signatory
For EKO PRO ENGINEERS PVT. LTD
Page No. 1/1Page 433
Solid Sample Analysis
Test Report No. : 15/04/2016Issue DateEK0/EV-SL/115/090416
TEST REPORT
Sample Description
Sample Received on
09/04/2016 To 15/04/2016
RESULTS
09/04/2016
500 gmSample Quantity
Shree Cement Limited
Bangaur City
P.O RAS- 306107
Tehsil- Jaitaram
Issued To
Distt- Pali (Rajasthan)
Analysis Duration
SOP-S/50
Sample Drawn on 08/04/2016
Fly Ash
EPEPL(Mr. Harish Kumar)Sample Drawn by
Sampling Plan & Procedure
NormalEnvironmental Condition
Remark (if any) NA
NASampling Location
PARAMETERS.No. Results UnitsTest Methods
Chromium Total (as Cr)1 2.52 mg/kgICP - MS
Lead (as Pb)2 1.76 mg/kgICP - MS
Mercury (as Hg)3 0.96 mg/kgICP - MS
Arsenic (as As)4 0.48 mg/kgICP - MS
Notes :
1. The results given above are ralated to the tested sample, as received & mentioned parameters.
The customer asked for the above tests only.
2. This test report will not be generated again, either wholly or in part, without written permission of the Laboratory.
3. This test report will not be use for any publicity/legal purpose.
4. This test samples will be disposed off after two weeks from the date of issue of test report, unless until specified by the customer.
Sample received for biological tests will be destroyed after 7 days from the date of issue of test report.
5. Responsibility of the Laboratory is limited to the invoiced amount only.
**End of Report**
Authorized Signatory
For EKO PRO ENGINEERS PVT. LTD
Page No. 1/1Page 434
Solid Sample Analysis
Test Report No. : 15/04/2016Issue DateEK0/EV-SL/111/090416
TEST REPORT
Sample Description
Sample Received on
09/04/2016 To 15/04/2016
RESULTS
09/04/2016
500 gmSample Quantity
Shree Cement Limited
Bangaur City
P.O RAS- 306107
Tehsil- Jaitaram
Issued To
Distt- Pali (Rajasthan)
Analysis Duration
SOP-S/50
Sample Drawn on 08/04/2016
Slag
EPEPL(Mr. Harish Kumar)Sample Drawn by
Sampling Plan & Procedure
NormalEnvironmental Condition
Remark (if any) NA
NASampling Location
PARAMETERS.No. Results UnitsTest Methods
Chromium Total (as Cr)1 9.16 mg/kgICP - MS
Lead (as Pb)2 2.25 mg/kgICP - MS
Mercury (as Hg)3 0.14 mg/kgICP - MS
Arsenic (as As)4 0.93 mg/kgICP - MS
Notes :
1. The results given above are ralated to the tested sample, as received & mentioned parameters.
The customer asked for the above tests only.
2. This test report will not be generated again, either wholly or in part, without written permission of the Laboratory.
3. This test report will not be use for any publicity/legal purpose.
4. This test samples will be disposed off after two weeks from the date of issue of test report, unless until specified by the customer.
Sample received for biological tests will be destroyed after 7 days from the date of issue of test report.
5. Responsibility of the Laboratory is limited to the invoiced amount only.
**End of Report**
Authorized Signatory
For EKO PRO ENGINEERS PVT. LTD
Page No. 1/1Page 435
~ 02932-231616
Regional office
Rajasthan State Pollution Control BoardSA-6, Mandia Road Industrial Area, Pali - Marwar.
No. RPCBIRO PalilL2-::>tf Dated: ('J, 111 12013
The Group Incharge (Mines),
Rajasthan State Pollution Control Board,
4, Institutional Area, Jhalana Dungari
Jaipur - 3020 04
Sub: Regarding non applicability of MOE&F Office Memorandum dated 15/3/2010 with respect
to the critically polluted area of Pali district for the site of the Integrated Cement Plant,
Power Plant and Nimbeti Limestone Mining of MIs Shree Cement Limited situated near
Village Ras,Tehsil1aitaran, District - Pali (Rajasthan).
Ref. : 1. Your letter no. F- Tech (C-144)/RPCB/CPMl424, dated 22.08.2013
2. The Shree Cement Ltd. letter no. SCLIRASlEnv/2012-13/12209, dated 26.09.2013
Dear Sir,
Apropos above and subsequent site visit carried by the undersigned on dated 08-10-2013, it is
informed that the distance of proposed Integrated Cement Plant, Power Plant and Nimbeti
Limestone Mining project from the critically polluted area 1 industrial cluster in Pali district are as
following: -
A. Existing Industrial Area :-
1. Mandia Road
2. Punayata Road
3. Sumerpur Road
Approx 102 KM
Approx 102 KM
Approx 102 KM
B. Pali Town : 102 KM.
* The distance of Sumerpur town is approx. 171 KM from the proposed project. The Road leading
towards Sumerpur Town is termed as Sumerpur Road viz. Pali - Sumerpur Road, near Pali, which is
approx. 102 KM from the site.
Therefore, looking to the aforesaid distances from the Shree Cement Units and Nimbeti Limestone
Mine site, there is no possibility of additional pollution load due to the proposed project on the
aforesaid critically polluted areas of the industrial clusters of the Pali district.
Enc\.: Copy of the verified location map of project with
respect to critically polluted area in Pali district.
Yours Faithfully
~o//r-J
~
(R. B. Maurya)
Regional Officeropy to: MIs Shree Cement Ltd,
Village-Ras.Tehsil-Jaitaran, District - Pali (Rajasthan).
~k~Region ffiCer
c.Q')'1]b~ JV6t?7.'1'
I~~~~~~~~,tfTF""
Page 436
[English Translation] Ph. 02932-231616
REGIONAL OFFICE
Rajasthan State Pollution Control Board
SA-6,Mandia Road Industrial Area, Pali
S.No. RSPCB/R.O. PALI/881 Date: 23.5.2016
Member Secretary,
Rasthan State Pollution Control Board,
Jaipur
Sub:- Details of Public Hearing conducted on 20.4.2016 for obtaining environmental Clearance for M/s. Shree
Cement P.O. Box No. 33 Bangur Nagar, Beawar, District Ajmer for Proposed expansion of Integrated Cement
Plant- Clinker (11.2 to 15.0 MTPA) Cement (8.8 to 13.2 MTPA), WHRS (68 to 90 MW), Captive power plant (180
MW), Synthetic Gypsum (1560 TPD) and DG Sets (1000 to 2000 KVA) at village: Ras, Tehsil: Jaitaran, District:
Pali.
Sir,
With reference to the aforesaid subject, we would like to inform you that Public Hearing for M/s. Shree Cement
Ltd. P.O. Box No. 33 Bangur Nagar, Beawar, District Ajmer for obtaining Environment Clearance for expansion
of Integrated Cement Plant - Clinker (11.2 to 15.0 MTPA) Cement (8.8 to 13.2 MTPA), WHRS (68 to 90 MW),
Captive power plant (180 MW), Synthetic Gypsum (1560 TPD) and DG Sets (1000 to 2000 KVA) at Village: Ras,
Tehsil: Jaitaran, District: Pali has been Conducted on 20.4.2016 at 3.00 PM. at Office of Sub Divisional Officer
Jaitaran, District Pali (Rajasthan). Signed copy of the details of Public Hearing Proceedings (Minutes) and
Videography CD (2 copy) and Photography (CD and Album) is enclosed for information and further action.
Enclosure: As above
Yours faithfully,
(Rajiv Pareek)
Regional Officer
RSPCB, Pali
S.No. RSPCB/R.O. Pali/ Date:__________
1. District Collector, Pali is informed and for further action enclosed C.D. & Photograph (C.D & Album).
2. Additional District Collector, Pali is informed & for further action enclosed CD & Photograph (CD &
Album)
3. A.C.P. RSPCB., Jaipur for uploading on board website the details of Public hearing Proceeding
(Minutes) in compliance with Board Headquarter vide Letter no. F. Tech (P-0158) RPCB/CPM/837 Dated
9.8.2011.
4. M/s. Shree Cement Ltd. P.O. Box No. 33, Bangur Nagar, Beawar, Ajmer at Village - Ras, Tehsil -Jaitaran
for necessary further action.
Regional Officer
RSPCB, Pali
Page 447
Public Hearing Proceedings
Public hearing for Environmental Clearance of proposed expansion of Integrated Cement Plant - Clinker (11.2 to
15.0 MTPA) Cement (8.8 to 13.2 MTPA), WHRS (68 to 90 MW), Captive power plant (180 MW), Synthetic
Gypsum (1560 TPD) and DG Sets (1000 to 2000 KVA) at Village: Ras, Tehsil: Jaitaran, District: Pali by M/s. Shree
Cement Ltd. has been Conducted on 20.4.2016 at 3.00 PM. at Office of Sub Divisional Officer Jaitaran, District
Pali (Rajasthan).
Details of the person present in public hearing alongwith their signature is attached as Annex ure "A".
Advertisement regarding Public hearing conduction was published in 18.3.2016 edition of Daink Bhaskar and
Daink Navajyoti. During the Public hearing detail discussion was carried out on the written memos received
which is clear by the working description. Photocopy of which is Annexed in Annexure B. Detail of Public
hearing as follows:-
First of all Mr. Rajiv Pareek Regional Officer, gives the brief description of the Project and invited Sh. Rakesh
Bhargav to give details of the project to the public and Respected District Magistrate Sh. Kumar Pal Gautam on
the stage.
• Sh. Rakesh Bhargav, V.P. (Environment) welcomes all the dignitaries on the stage and all the visitors
from different villages a nd gave the details of executive summary of the expansion of integrated
Cement plant which is as follows:-
� Clinker - 11.2 to 15.0 MTPA
� Cement - 8.8 to 13.2 MTPA
� WHRS - 68 MW to 90 MW
Shri Bhargav tells that following Management systems are followed by Shree Cement:
• ISO 9001 - Quality Management System
• SA 8000 - Social Accountability
• ISO 14001 - Environment Management System
• ISO 50001 - Energy Resource Management
• OHSAS 18001 - Occupational Health and Safety Evaluation
He tells that now a days there is increase in global temperature, so it is our responsibility to decrease the
emission of CO2 and utilizing energy from Waste heat and other energy sources. Shree Cement Ltd. is
committed to decrease Co2 emission.
• He said that we want to increase the production of clinker from 11.2 to 15.0 MTPA. For that
expansion in 9 and 10 unit will be done and unit 11 with 2.6 Million metric tonnes per annum
capacity will be established. Also for increasing cement production from 8.8 to 13.2 Million metric
tonnes VRM and Ball mill will be installed, 180 MW of Captive Power Plant will be installed,
increase in capacity of WHRS from 68 MW to 90 MW, expansion in D.G. Set Capacity from 1000 to
Page 448
2000 KVA, 1560 tonnes per day of synthetic Gypsum Unit and in 40 hectare area near village
Bhagatpura township of builtup area of 136766 Square meter.
• For all this we got TOR letter on 11th
February, 2015, via letter No. J 11011/343/2012-1A 11(I) dated 1th
Feb., 2016 from Ministry of Environment, Forest and Climate change, New Delhi. Baseline study
period was from March to May 2015.
• Advertisement regarding Public hearing was published in two news papers Navjyoti and Dainik
Bhaskar on 18th
March, 2016.
• Environmental status of the study area is shown in the presentation which is as. Reserved forest in
South -South East direction 5 Km. away and protected forest 9.9 Km. South East direction.
� Basic requirement of the project are as follows:-
• Total water requirement of plant, mines and Bhagatpura Colony is 4000 Cubic meter per day.
• Total energy requirement which is 158.9 MW for that we have CPP, WRHS and grid. D.G. Sets are
available for emergency back up of plant.
• Additional manpower requirement is 100 and total man power available after the expansion will
be 1393.
• Total cost of the proposed expansion will be 755 crores. Cost for Environment protection measure
will be 51 Crore and recurring cost will be 1 crore per annum
� Giving details of Production process he tells -
• Cement Plant, With Pre heater and Pre Calcinator technology, Cement Plant is based on dry
process technology for cement and clinker Production.
• Power Plant is based on air cooled condenser technology.
• Waste Heat released from Clinker unit is used for production of energy without fuel.
• Lime Stone which is the major raw material will be taken from the captive limestone mines by
conveyor belt. Other raw materials like Laterite, Gypsum, Coal, Pet Coke, fly Ash, Lead Zinc
slag and Clinker will be transported from outside by road and rail.
It is important to mention over here is that no waste is generated in our premises and if it is generated
than it is given to authorized CPCB recyclers.
Noise, Air, Surafce Water and Soil analysis has been done at various places which is shown in the
picture.
� Description of baseline study of environment is as follows:-
• At 12 places comprehensive Air quality analysis was done and the analysis of various particles
found in dust are shown in the picture which is as follows:-
� PM10 - 56.2 to 81.0 microgram per Cubic Meter (mg/m3)
� PM 2.5 - 20.6 to 38.1 microgram per Cubic Meter (mg/m3)
� So2 - 5.2 to 98 microgram per Cubic Meter (mg/m3)
Page 449
� NO x - 14.2 to 26.3 microgram per Cubic Meter (mg/m3)
Results found are far less than the prescribed standards:-
• Selected 12 Noise analysis areas description is as follows:-
� Noise level at day time 50.2 to 63.2 Leq dB (A)
� Noise level at Night time 3 9.4 to 57.1 Leq dB(A)
• Collection of samples was done at 9 places for ground water quality in which TDS varies from
978 to 1489 mg/l, PH varies from 7.08 to 7.56, total hardness varies from 360.80 to 581.12 mg/l.
• Soil quality analysis shows that pH varies from 7.26 to 8.01, organic carbon from 0.40 to 0.67
%, Nitrogen from 174.89 to 223.98 Kg per hectare and phosphorus from 14.93 to 19.08 Kg. per
hectare.
� He told that what impact will occur on the environment due to this expansion. For knowing this they
are calculating maximum incremental concentration,the details of which is given in the figure. All the
pollutants will be within prescribed standard.
� While ana lysing Environmental Mana gement plan he sa id that.
• For air quality management bag house will be installed in kiln, coal mill and cement will and
ESP in clinker cooler will be installed
• Bag filters will be installed at every transportation points.
• Vacuum Sweeping will be done and paved road will be constructed.
• Clinker, cement and fly ash will be stored in silos
• Gypsum, coal and pet coke will be stored is covered sheds.
� While Descr ibing the Noise Management he said-
• Proper maintenance, oiling and greasing of machines at regular interval are done to keep the
noise level low.
• Personal protective equipments like Ear muffs and ear plugs will be provided to all employees
working in high noise generating areas.
• Compressor and Turbine will be established in closed building.
• Green Belt of appropriate width has been developed all along the plant boundary and will be
further enhanced
• Regular monitoring of noise level is being/ will be carried out and corrective measures in
concerned machinery will be adopted accordingly to the possible extent
� While Descr ibing the green belt development he said:-
• Out of the total existing plant area (i.e. 187.56 ha), about 63.8 ha (i.e. 34% of the total existing
plant area) has already been developed under green belt / plantation.
Page 450
• Additional 38.5 ha (33 %) will be further developed under green belt/ plantation for new
proposed area in order to reduce dust & noise pollution levels & to increase aesthetic beauty
of the area.
• Presently there are 164972 numbers of saplings in 63.8 hectare area.
• SCL is now proposing to develop 1000 trees and shrubs/ hectare in new proposed area.
Shri Rakesh Bhargav said as shown in figure, green belt is being/ will be developed in plant premises and
near by villages.
� While focusing on solid and hazardous waste management he said that Shree Cement is not
generating any waste and we are using wastes of other industries in our plant. All ash generated in
power houses is used for production of cement.
Sludge from STP plant is used of as manure for development of green belt. As per Ministry guideline
waste generated from other units like paint sludge, automobile, ETP sludge, phosphate sludge, CETP
sludge etc is used as A.F.R. waste oil generated is sold to CPCB authorised recyclers.
� He said on water management that
• No waste water is generated.
• We have installed STP
• Waste water from R.O. is used in synthetic gypsum plant and water will be used for dust
suppression and ash quenching.
• Rain water harvesting is done within the plant premises.
� Giving description of occupational Health and safely he said that Shree Cement as given in figure is
maintaining healthy and safe working environment for workers. These methods are same as given in
mines.
� Details of C.S.R. done by Shree cement are as follows-
• As given in figure we are doing more work on education of children.
• Under women's empowerment and skill development program, training of Sewing, hand
embroidery, Beauty parlour and speaking is given. In 2014 around 200 peoples get benefit
from this
• We provide support in marriage of B.P.L. Families. We provide aid of Rs. 25000 to girls with
age of more than 18 years for selected families. In 2015-16 we support in marriage of 26 girls.
• We have made women's self help groups which are 9 in number in which total number of
women is 108. Total saving of the group is Rs. 3,40,019 and bank loan for 5 groups is Rs.
4,85,000.
• Under save girl child campaign we have supported B.P.L. families for fixed deposits of Rs.
5,000 for 18 years and this amount can be withdrawn only when the girl attains 18 years of
age. In 2015-16, 13 girls are benefitted by this.
Page 451
• Under Youth Employment training, we are providing training of low budget Toilets, Plumber
mason and mobile repairing to the youth. Till now around 209 people get benefitted from
this.
• Under drinking water plan, we supply drinking water in summer season. Around 450 students
from Govt. School of Kheda, Bhagatpura and Bhimgarh are getting benefits from this.
• Under Drinking water supply scheme, we have installed tube wells, submersible motor,
underground pipeline, as mentioned in the figure and around 1100 peoples got benefit from
this.
• Under agriculture and horticulture development program, with the help of Government
Agriculture and horticulture department, we provide subsidy to farmers for Agricultural
equipments like sprinkler set, sprayers, chaff cutter etc. In 2015-16 around 95 farmers was
benefitted by this program.
• We also distribute seeds under which in 2015-16 around 743 farmers was benefitted.
• Under sapling distribution program , we distribute saplings of fruits bearing plants which
includes mainly Pomegranate (Anar). Ber, Nimbu, Bail patra, Genda and plants providing
shades. Around 12870 and 4652 plants (saplings) were distributed in year 2014-15 and 2015-16
respectively.
• Shree Cement is working for strengthening and self employment of farmers, for that we take
farmers to Krishi Vigyan Kendra, Ajmer and trained them for organic farming. Its seems from
the picture that farmers are benefitted from this tour. Around 874 farmers are benefitted
from this till now.
• We organized meeting regarding planning and awareness at village level, which create
awareness among vi llagers about the different developmental issues. From the given pictures
it is clear that villagers involvement in this program is very much. In these meetings issues like
agriculture issue, livestock management, land are discussed. For this we have organised 10
awareness camps.
• Regarding livestock management he said that from this picture it is clear that to prevent
animals from disease, we provide vaccination and we aware people for that. Till now 11574
animals are benefitted.
• Giving detail regarding natural Resource Management he told how Shree Cement is making
dams and anicut for conservation of water . He display the pictures of dams and Anicut
made by Shree Cement.
• He displays the pictures of social and religious programmes supported by Shree Cement.
Page 452
• Under infrastructure development program, 11 hathai sheds are constructed. To improve the
health facilities in nearby villages Sub Health Centres are constructed in village Bhimgarh and
Bhagatpura.
• In nearby villages 12 Multipurpose community centres are constructed. Also in Jawangarh,
Bhimgarh and Ja gtiya, boundary wall has been constructed of four government schools.
• At 18 places in nearby villages roads have been constructed and around 6000 meter have
been constructed in 12 villages. In 2015-16 in Butiwas and Pratap Nagar Cemented road is
constructed. In Six different government schools s ix different additional classroom are
constructed. 23 water tanks - Pyau are constructed in different villages till now. Seven culverts
are constructed in five villages and repairing of one pipe culvert at Jawangarh in year 2015-16
has been done.
• 18 khelis are constructed for animals.
• Under- Employee self service sa fety School and social awareness program, school safety
awareness program, Computer Education in schools, Drawing training for engineering etc are
organised and rallies are organized on anti-tabacco day and AIDS Day.
� Therefore it is very clear, how Shree Cement is working for society by creating awareness programmes
and how people are benefitted.
� Elucidating about the awards received by Shree Cement Shri Rakesh Bhargav shows photographs that
they have received awards from different Government and non-government organisations. It shows
clearly that Shree Cement is working towards Control of Pollution.
• In 2012 Mother Teresa Award for Corporate Citizenship was awarded
• In 2013 Corporate Governance Award for Best C.S.R. Practices
• In 2014-15 Bhamashah Award was given
• In 2015, FICCI CSR award for best C.S.R. Practices
� This Shows that we are full filling our C.S.R. responsibilities very well. Then w hile mentioning news
coverage, he told that it is all in front of you how and where Shree Cement is working a nd with this he
thanks to all the villa gers for listening him peacefully and complete the presentation.
� After this Honourable Collector Shri Kumar Pal Gautam Ji said after listening to complete description if
any one has any suggestion or want to say something about this proposed expansion he/she can say it.
1. On this one villager stands up and said that due to Shree Cement development along with
employment opportunity has increased in the area. No one should have any objection with the
proposed expansion of this project.
2. Villagers said that due to Shree Cement drinking water problems of the area has been solved and
people are getting employment nearby their homes.
3. Along with this Shree Cement helps in construction of schools and hospitals in villages.
Page 453
4. Villagers told that they are satisfied by Plantation and C.S.R. activities done by Shree Cement and
there is no problem of pollution.
5. Some villagers raised objections for pollution from Cement plant in verbal and written application
which is enclosed with this proceedings.
� During Public hearing applications are received from following which are enclosed here:-
Details of Application received during public hearing held on 20.4.2016
S.No. Name and Address
1. Shri Ajeet Singh, Village: Babra, Amar Singh r/o Ras, Javan Singh, vi llage: Andheri Dewri,
Tehsil: Jaitaran, Pali
2. Tej Singh Gurjar, Village: Ras, Tehsil: Jaitaran, Pali
3. Pappu Kathat, Mangla Paras Kathat, Chaina, Village: Bhagatpura Tehsil: Jaitaran, Pali
4. Paras, Ugmaram, Raju Bhai, Bhakar, Paima, Raju, Village: Bairuji Ki Dhani, Tehsil: Jaitaran, Pali
5. Kaluram, Rajasthan Situ Union, Jaitaran, Pali
6. Puran Singh, Govind, Rakesh, Seema, Suva Lal, Village: Butiwas Jaitaran, Pali
7. Lunaram Tanwar Ex-Director, Agricultural Product Market Committee, Jaitaran, Pali
8. Raj Kathat, Arjun Kathat, Jaitaran, Pali
9. Kaluram Gurjar, Village: Nimbeti, Jaitaran, Pali
10. Shiv Lal Gurjar, Village: Gopaldara (Babra) Jaitaran, Pali
11. Dayalram Gurjar, Village: Kheda (Ras), Jaitaran, Pali
12. Rekha Tailor, Pratapi, Jaitaran, Pali
13. Arvind Singh (State General Secretary) Janta Adhikar and Village Development Center, Village
:Sevariya, Jaitaran, Pali
14. Rasa Singh Rawat (Panchayat Committee member), Ward No. 13, Gram Panchayat Ras-
Sevariya, Jaitaran Pali
Rajeev Pareek Kumar Pal Gautam
(Regional Officer) ( District Collector )
Raja sthan State Pollution Pali (Rajasthan)
Control Board, Pali (Rajasthan).
Page 454
Raiasthan
RAJASTHANSTATE POLLUTION CONTROLBOARD
4, Institutional Area, Jhalana Doongari, Jaipur-302 004
Phone: 0141-5159600,5159695Fax: 0141-5159697
www.rpcb.nic.in
Revised Authorization
./File No: F(HSW)/PALI(jaitaran)/1(1}/2008-2009/913-915 Dater- 24/06/2015
Unit Id 489
Mis Shree Cement Ltd.~~ngur Nagar, Post Box No. 33, AndheriDeori Tehsil:Masuda
District:Ajmer
Sub» Authorization for operating a facility for Collection, Disposal, Generation, Reception,
Storage, Treatment of Hazardous Wastes Under Hazardous Waste (Management,
Handling and Transboundary Movement) Rules, 2008.
Ref:- Your application dated: 20/06/2013 received on 02/07/2013 and subsequent corresponde
Sir
Number of authorization RPCB/HWM/2015-2016/SWMC/HSW /25.
2 Vice President (Environment) of M/s Shree Cement Ltd. is hereby granted an
authorization under Rule 5 (4) of Hazardous Waste (Management, Handling and
Transboundary Movement) Rules, 2008 made under the Environment
(Protection) Act, 1986 to operate a facility for Collection, Disposal, Generation,
Reception, Storage, Treatment of Hazardous waste on the premises situated at
Premises of M/s Shree Cement Ltd" Ras District: Patio
3 The authorization is granted for the Collection, Disposal. Generation, Reception, Storage,
Treatment of hazardous waste of following categories in the premises of the industry only.
SNo Type of Category Quantity/ Hazardous Waste
Hazardous wasteSch Code
Unit Disposal Practice
1 Phosphate sludge 50.00 Utilization for co) 12.5
TPD processing
2 Process Wastes, residues and 150.00 Utilization for co
sludges ) 21.1TON/DAY processing
3 Chemical sludge from waste 50.00 Utilization for co
water treatment I 34.3TPD processing
4 Used/ spent oil . 300.00 Sales to RegisteredI 5.1
KLA Recycler
5 Tyre Chips 500.00 Utilization for co
I OWOlTON/DAY processing
4 The authorization shall be in force for period from 20/06/2013 to 30/05/2018 .
Page 1 of4
Page 461
RAJASTHANSTATE POLLUTION CONTROLBOARD
4, Institutional Area, Jhalana Doongari, 'aipur-302 004
Phone: 0141-5159600,5159695Fax: 0141-5159697
www.rpcb.nic.in
Revised Authorization
RMlsthf!D
File No: F(HSW)/PALI(Jaitaran)/1(1)/2008-2009/913-915 Date» 24/06/2015
Unit Id 489
5 That this authorization shall ceased to be valid & shall be liable to be revoked
without any further notice in case of refusal/expiry of consent to operate under
the provrsions of Water(Prevention and Control of Pollution) Act,1974 and
Air(Prevention and Control of Pollution)Act,1981 by the State Board.
6 That no recycling/re-processing of the hazardous waste covered under schedule
IV shall be carried without prior valid registration with Competent Authority as
recycler/ re-processor of hazardous waste under the rule 8 of the HW (M,H
TM)Rules,2008.
7 That in case of any expansion or change in process or product or change in mode
/ practice of disposal of hazardous waste or its quantity, industr-y shall obtain
fresh Authorization.
U That the authorization shall be treated valid with valid Consent to Operate under
Water Act/Air Act.
9 That the industry shall utilize Paint Sludge from Automobile sector (Hazardous
Waste cat 21.1), Phosphate Sludge (Hazardous Waste cat. 12.5) and ETP Sludge
(Hazardous Waste Cat. 34.3) for co-processing as per the regular permission
granted by the CPCB vide its letter no. B-33014/H-34/2009/PCI-II/5252 dated
20/09/2011 and letter no B-33014/2012/PCI-II/1576 dated 24/05/2013
respectively. The unit shall comply with all the conditions of regular permission
issued by CPCB vide the aforesaid letters.
10 That no other hazardous waste shall be utilized for co-processing as a
supplementary resource or for energy recovery, or after processing without
prior & valid approval Central Pollution Control Board under the rule 11 of the
HW(M,H &TM) Rules 2008.
11 That the industry shall comply the procedure and norms for collection,
transportation, storage, record keeping, air poUutJon control requirements,
emission standards, monitoring requirements as specified in the Guidelines 011
Co-processing in Cement/Power/Steel Industry issued by CPCB in Feb. 2010.
12 That this authorization shall ceased to be valid & shall be revoked without any
further notice in case of refusal/expiry of approval for utilization of hazardous
waste as a supplementary resource or for energy recovery, or after processing
under Rule 11 issued by the Central Pollution Control Board.
13 The authorization IS subject to the conditions stated at Annexure "A" enclosed with the
authorization letter and the such conditions as may be specified in the Rules for the time
being forced under the Environmental (Protection) Act, 1986.
Page 2 of 4
Page 462
RAJASTHANSTATE POLLUTION CONTROLBOARD
4, Institutional Area, Jhalana Doongari, Jaipur-302 004
Phone: 0141-5159600,S159695Fax: 0141-5159697
www.rpcb.nic.in
Revised Authorization
Raltlslhap
File No: F(HSW)/PALI(Jaitaran)/1(1)/2008-Z009/913-915 Dater- 24/06/2015
Unit Id 489
14 The unit has to display and maintain the data online outside the factory main gate in lIindi
& English both on a 6'X 4' display board in the manner & format prescribed at Annexure
"B" and the report of the Compliance along with photograph shall be submitted to this
office & Regional Office. time to time.
15 That the annual
submitted to the
reports/returns in the form prescribed under the Rules shall 1)('
Board by 30th June of every year and records of hazardous waste
Generation, handling & management shall be maintained according to the provisions of
the Hazardous Waste (Management. Handling and Transboundary Movement) Rules, 2008
and shown & submitted to the Board as and when asked for.
16 The hazardous waste should not be stored for a period beyond 90 days, failing which the
authorization shall deemed to be revoked.
17 It shall be ensured that the Hazardous waste is handled, managed & disposed of strictly
in accordance with the Hazardous Waste (Management. Handling and Transboundary
Movement) Rules. 2008. Non compliance of the Rules or any of the conditions contained
10 the authonzanon shall be tantamount to automatic cancellation/revocation of the
authorization.
18 The operator of the facility shall liable to· comply any other conditions as per the
guidelines isssued by the MoEF or CPCB or State Board related to collection, disposal,
reception, storage & treatment of hazardous waste.
19 That this revised authorization letter shall supercede the earlier authorization letter no
2013-2014/SWMC/HSW /84/3031-3033 dated 18/07/2013
20 That Authorization is issued under the provisions of Hazardous Waste
(Management ,Handling and Transboundary Movement) Rules, 2008 from the
environmental angle only, and does not absolve the project proponent from the
other statutory obligations prescribed under any other law or any other
instrument in force. The sole and complete responsibility, to comply with
conditions laid down in all other for the time-being in force, rests with the
industry/unit/project proponent.
21 That this Authorization shall not, in any way, adversely affect or jeopardize the legal
proceeding, if any, instituted in the past or that could be instituted agamt you by the
State Board for violation of the provisions of the Act or the Rules made thereunder.
Page 3 of 4
Page 463
R@jasthap
RAJASTHAN STATE POLLUTION CONTROL BOARD
4, Institutional Area, Jhalana Doongari, Jaipur-302 004
Phone:0141-5159600,5159695Fax:0141-S159697
www.rpcb.nic.in
Revised Authorization
FileNo: F(HSW)/PALI(Jaitaran)/1(1)/Z008-Z009/913-915 Date» 24/06/2015
Unit Id 489
This bears the approval of the competent authority.
Yours Sincerely
Grouplncharge
CopyTor-
1 Regio I Officer, Regional Office, Rajasthan State Pollution Control BoardPali to
e compliance of conditions
2
Page 4 of 4
Page 464
\ ) u.
J
TERMS AND CONDITIONS OF AUJfHORISATION
( I) The authorization shall comply with the provision of the Environment (Protection) Act, 1986 and the rules made
there UI der.
(2) The autt orization or its renewal shall be produced for inspection at the request of an officer authorized b~ ~hl'
SPCB..
(3) The person authorized for hazardous waste management shall not rent, lend, sell transfer or otherwise transport tlw
hazardoi s waste without obtainirg prior permission of the SPCB.
(4) All) una rtnorized change in personnel, equipment and working conditions as mentioned in the application b~ til...·
person authorized shall constitute a breach of his authorization.
t 5 I It is duty of the authorized person to take prior permission of the SPCB before closing down the facility
(01 An apptication tor the renewal ofan authorization shall be made as laid down 111 Rule 5 (6) (ii)
(7) The occ rpier and operator of the authorized facility shall maintain records of its operations and send annu.u
returns to the SPCS' in the specif-ed Form 4 respectively.
18\ Before transferring ownership or operation of a facility during its operating life. Or of a disposal facilir, during th,
post closure care period, the owner or operator must seek prior permission of the $PCB and must nOlit) the nl'\\
'occupier' or 'operator' in writing of the requirements of this authorization. The new occupier or operator ,h,d.
comply with all applicable requirements of the authorization granted to the facility.
(9) Before a1 occupier or operator transports. Treats, stores, or disposes off any hazardous waste. Occupier or operator
of a facility must conduct a detai ed physical and chemical analysis ofa representative sample of the waste as per ,I
written waste analysis plan to be developed and followed by the Occupier or Operator of a facility and appro- n1
by the S )eB. At the minimum, this waste analysis must contain all the information which must be known to treat.
store or dispose off the waste. At the minimum. 'the waste analysis plan must specify:
a. The parameters for which each hazardous waste will be analyzed and the rationale for the selection of tnc-«:
para meters.
h. The sampling method to obtain a representative sample of the waste to be analyzed.
c The test method. which will be used to test these parameters.
d. The laboratory in which the analysis s to be carried out.
c.' The frequency with which ':he initial analysis of the waste will be reviewed or repeated to ensure li1.ll lIJ,
analvsis is accurate and up :0 date. (The analysis must be repeated as necessary to ensure thai it IS <llTU\"ll
and up to date. At the minimum, the analysis must be repeated. wherever there is a change if' tile procevs ,:1111
opel ation generating the hazardous waste.)
( 10) For 01'1'- site facilities. the occupier or operator must inspect and if necessary, analyze each hazardous " :ht.
consignr ient received at the facility to determine whether it matches with the identify of the waste specified (1(1 ih,
accompanying manifest.
I II) Ihe occupier and operator must orevent i.nknown entry and minimize the possibility for the unauthorized t:ntr~ ,'1
persons or livestock onto the active portions of his (her) facility. There should be an appropriate 24 I'lllll
surveillance system, a natural and artificial barrier surrounding the active portion of the facility. and a means I,
control entry at all times through the gales. Signs with the legend "Danger- unauthorized personnel keep out" muxt
he posted at each entrance to active portion ofa facility. The legend must be written in English and 111 Vernacular
Language predominant in the area surrounding the facility and must be legible from a distance orat least IOIll
( J 2) The occupier or operator must develop and maintain a written schedule tor inspecting all monitoring equlpmellt
safety and emergency equipment, security devices and equipment that are important lor preventing delt:<..:\\I\g.101
responding to environmental or human health hazards. The schedule must identify the type of problems to look tOI
during ihe periodic inspection by the occupier/operator and frequency of inspection to each item of schedule 11'1
mspectic n details including date and time of inspection, name of the inspector. observations during mspecuor •.
nature and details of any repairs or other remedial actions shall be recorded and such records shall he maintained
101' at least 3 years.
I IJ) ,\11 the Iscility personnel must be well informed about the hazardous waste management procedure relevant I' -:.:
positiorn in which they arc em): loyed. A II the facility personnel must be trained to ensure that thc~ are able t·
respond effectively to ernergenc es by familiarizing them with the emergency procedures. emergency equipment
operations and communication 01' alarm systems,
Page I 01'3
Page 465
•
. ,It
(14) Facilities must be established, tasted periodically and maintained to minimize the possibility ola fir,
any unplanned sudden or non-sudden release or hazardous waste to air, soil, sub surface or surface
could threaten human health or environment.
(15) Wherever and whenever hazardous material is being handled, all personnel involved in thc operation 11.
immediate access to an internal alarm or emergency communication device, such a; a telephone capable 01
for external assistance.
( 16) The occupier or operator of' the facility must maintain aisle space to allow the unobstructed move men'.
personnel and equipments to any area of the facility in an emergency.
( 17) The occupier of operator of the facility must make arrangements, as appropriate for the type of waste handled at
the facility, '
a. To familiarize police, fire departments and emergency response terms with the layout of the facility. properties 01
hazardous waste handled at the facility and associated hazards and possible evacuation routes.
b. To familiarize local hospitals with the properties cf hazardous waste handled and the type of injuries or illnessc-,
this could result from fires, explosions or releases at the facility.
(18) Each occupier or operator of the facility must develop, implement, maintain and keep up to date, a conungency
plan designed to minimize impacts on human health or the environment from fires explosions or any unplanned
sudden or non- sudden release of hazardous waste to air, soi or water environment.
The contingency plan must include.
a, Arrangements agreed to by local police departments fire departments hospitals State and local crnergcr«; \
response terms to coordinate emergency services
b. List of names, addresses and phone numbers of all persons qua Iified to act as emergency coordinator who IS
responsible for all emergency response measures.
c. List of all emergency equipment at the facility, lind
d. Evacuation plan for facility personnel where there is a possibility that evacuation could be necessary
fL@sponation and recet,tion of hazardous wastes:
( 19) An occupier or operator who transports or offers for transportation, hazardous wastes for off-site treatment.
storage or disposal, must prepare a manifest, in six copies, and must designate on the manifest one facility which 1\
permitted to handle the waste described on the mani fest.
(20) The occupier/operator who offers the wastes for transportation must:
a. Sign the manifest certification by hand
b. Obtain hand-written signature of the transporter and the <late of acceptance.
c. Retain one copy and send one copy to the SPCB, and
d. Give the remaining copies of the manifest to the transporter for necessary action Is per manifest system
(21) Before transporti ng of hazardous waste or offering hazardous waste for transportation off-site. the
occupier/operator must package the waste in accorcance with the requirements 10 respect of packaging, labelmg
and marking.
(7.2) An occupier/ operator shall not offer for transport or receive hazardous wastes from a transporter who has 11111
received an authorization, for transport of hazardous wastes, fom the SPCB.
(13) A transporter must not accept hazardous waste from a generator unless it is accompanied by a manifest signed [n
the generator. The transporter must sign and date the manifest acknowledging accept snce of the hazardous wast«
from the generator and ensure that the manifest accompanies the hazardous waste.
(24) A transporter who delivers a hazardous waste to the designated facility, indicated in t ie manifest must obtain lhL
date ofthe delivery and handwritten signature of the operator of the designated facilit. on the mani fest. rCl<\\1lnne
copy of the manifest for a period of three years and give the remaining copies of thl manifest to lhe ueslgll<llc(\
facility.
(25) In the event of an accident and discharge of hazardous waste during transportation. the transporter must take
appropriate immediate action to protect human healtl and the environment, (e.g. notil ~ to SpeB. local police and
district administration, build a dyke to contain the discharge area) and must clean up t:le discharge as requiremem
and approved by the State Board,
(26) If a facility receives hazardous waste accompanied by a manifest, the operator must Sign and date each cop)' or themanifest to certify that the hazardous waste as per the manifest was received.
I r-RM.-S.i\NP CONDITIONS OF AUTHORISATION Page 2"f3
Page 466
a. Record any significant discrepancy in the Manifest.
b. Immediately give the transporter at lest one copy of the signed manifest.
c. Within 15 days from the date of delivery send a copy of the signed manifest to the generator and 1(' 1!1"
-,P<'B/PCC.
d. Retain at the facility a copy of each manifest.
C!.7) Manifest discrepancies are differences between the quantities or type of hazardous waste desrgnuted on I~,t'
man ires. and the quantity or type of hazardous waste a facility actually receives.
(2X) If the gmcratorlSPCBss do not get back the signed manifest from the designed facility , generator has 10 brrng 1111
to the notice of SPCBs and appropriate action has to be initiated by the SPCBs to identi fy and recut ~ th~'
deficiency.
(29) A transporter should engage drivers, pro v ided with special training for handling and transport of hazardous \\ ilSt.:,
Vehicle.: transporting the hazardous wastes and shall carry the Transport Emergency (TREM) card, In the event ,)1
accidental spillage during transport the instructions of the TREM card has to be followed.
(30) Driver I 'aining shall, at the mini num, include:
a. US( of the manifest system
b. US( of emcrgency equipment, such as fire extinguisher, gas mask, first aid etc
c. Procedure to be followed in case of an emergency during transit
d. USl ofTREM card
C\ \) If the transporter cannot delive. the hazardous waste in accordance with the requirements he must contact :/H'
generate r for further directions.
13.~) The trar sporter should ensure that ignitable, reactive or non-compatible waste are not transported along \\ Ith Ihl
other wr.ste. The transport vehicle should have proper lining cover, cushioning, shock absorbers etc.
IIA0JQI"LNG ,II,]\D STORAGE OF HA2-ARDQ.US WASTES
(].») Oil-site uorage of the hazardous waste shall be permitted for a maximum period of90 days, maximum quanuiy "I
10 LOne; 01' a truck load, whichever is less, unless otherwise specially permitted. It must be stored 111 .11i
environmentally sound manner ie. in isolated location away from the plant operational area,
(.\.1) The off-site storage at a hazardo rs waste treatment, storage and disposal facility shall be permitted for a minimun:
period ai required for economical and efficient treatment/disposal of the hazardous wastes,
\3~) The stOIage facility should have an appropriate containment system as per the "Spill Prevention, Control ,111'1
Counter Measures Pian", approved by the SPCB,
;:Ill) Each container holding hazardous wastes shall be marked "HAZARDOUS WASTF" in red color. both if' F,lIgll~h,
Hindi and in Vernacular language (s)
(37) The occ rpier or operator must take precautions to prevent accidental ignition or reaction of Ignitable or reacu «
wastes, !,uch waste must be separated and protected from sources of ignition or reaction including, out not III "l~' ..
(0. open flames, smoking. cutting and welding, hot surfaces, frictional heat, water, sparks, radiant hear eli ...
(38) The containment system in the storage area should be designed and operated to
a, Have an underlying base free from cracks and sufficiently impervious to contain leachate an) leaks, ~rilh ':IL'
b. Ora nand remove liquids which may result from leak, spill or precipitation.
(.." Contain at least 1-% of the volume of containers or the largest container whichever is higher
d. "Ru i-on" into the containment syster i should be prevented
e. l luve a slump or collection area to collect any leak, spill or precipitation and provision for Immediate trall~llI
01' t~ e same to prevent overflow of the collection system,
(39) Hazardo JS wastes must not be placed in tanks for storage/treatment. Otherwise. it could cause the LUn~ P' it< 11,\·:,'
(0 rupture. leak, corrode and fail before the end of its intended life, Uncovered tanks must be operated 10 ensure _,\
least 60 ern free board.
(40) The was e oil 01' spend/used oil will be sold/auctioned only to the refiner having valid registration With Milmt;'
of Environment and Forest Government of India/Central Pollution Control Board, Deihl as actual user He ShUll!-!
also have valid authorization under Hazardous waste management rules and also consent under Air and Water \~.(
Issteu I'I')m the related State Board,
Environmental Engineer S\\ 1\H. I
Page 'J of I
Page 467
Revised Authorization
Rajasthan
RAJASTHAN STATE POLLUTION CONTROL BOARD
4, Institutional Area, Jhalana Doongari, Jaipur-302 004
Phone: 0141-5159600,5159695Fax: 0141-5159697
File No: F(HSW)/PaIiOaitaran)/13(1)/2015-2016/1738-1740 Date:- 11/08/2015
Unit Id 59871
M/s Shree Cement Limited s
Village Ras, Tehsil.laitaran
District: Pali
Sub:- Authorization for operating a facility for Collection, Disposal, Reception, Storage,
Treatment of Hazardous Wastes Under Hazardous Waste (Management, Handling and
Transboundary Movement) Rules, 2008.
Ref:- Your application dated: 05/01/2015 received on 15/01/2015 and subsequent corresponde
Sir
1 Number of authorization RPCB/HWM/2015-2016/SWMC/HSW /54.
2 Vice President (Environment) of M/s Shree Cement Limited s is hereby granted an
authorization under Rule 5 (4) of Hazardous Waste (Management, Handling and
Transboundary Movement) Rules, 2008 made under the Environment
(Protection) Act, 1986 to operate a facility for Collection, Disposal, Reception,
Storage, Treatment of Hazardous waste on the premises situated at Village Ras,
Tehsil [aitaran, District: Pali.
3 The authorization is granted for the Collection, Disposal, Reception, Storage, Treatment
of hazardous waste of following categories in the premises of the industry only.
SNo Type of Category Quantity/ Hazardous Waste
Hazardous wasteSch Code
Unit Disposal Practice
1 waste/residues containing oil 200.00 CoProcessing in
(Grinding Waste) I 5.2TPM Cement kiln
2 Wastes / residues containing 200.00 CoProcessing in
oil (Oilsoaked cotton) I 5.2TPM Cement kiln
4 The authorization shall be in force for period from 11/08/2015 to 31/07/2020 .
5 That this authorization shall ceased to be valid & shall be liable to be revoked
without any furthor notice in case of refusal/expiry of consent to operate under
the provisions of Water(Prevention and Control of Pollution) Act,1974 and
Air(Prevention and Control of Pollution)Act,1981 by the State Board.
6 That no recycling/re-processing of the hazardous waste covered under schedule
IV shall be carried without prior valid registration with Competent Authority as
recycler/ re-processor of hazardous waste under the rule 8 of the HW (M,H TM)
Rules, 2008
Page 1 of 3
Page 471
RAJASTHAN STATE POLLUTION CONTROL BOARD
4, Institutional Area, Jhalana Doongari, Jaipur-302 004
Phone: 0141-5159600,5159695Fax: 0141-5159697
Rajasthan
Revised Authorization
File No: F(HSW)/PaliOaitaran)/13(1)/2015-2016/1738-1740 Date.- 11/08/2015
Unit Id 59871
7 That no other hazardous waste shall be utilized for co-processing as a
supplementary resource or for energy recovery, or after processing without
prior valid approval of Centratj.Potlution, Contra .Board- u-..~..G~.-the rul- "'1-UI .he
HW (M,H TM) Rules,2008.
8 That in case of any expansion or change in process or product or change in mode
/ practice of disposal of hazardous waste or its quantity, industry shall obtain
fresh Authorization.
9 That the authorization shall be treated valid with valid Consent to
Operate under Water Act/Air Act.
10 That the industry shall utilize grinding waste and oil soaked cotton (Hazardous
Waste Cat.S.2) of M/s Gillette India Limited, Bhiwadi for co-processing in cement
kiln as per the regular permission granted by the CPCB vide its letter no.
B-33014/201S/PCI-II/ dated 04/06/2015. The unit shall comply with all the
conditions of regular permission issued by CPCB vide the aforesaid letter.
11 That the industry shall comply the procedure and norms for collection,
transportation, storage, record keeping, air pollution control requirements,
emission standards, monitoring requirements as specified in the Guidelines on
Co-processing in Cement/Power/Steel Industry issued by CPCB in Feb. 2010.
12 That this authorization shall ceased to be valid and shall be :revoked without any
further notice in case of refusal/expiry of approval for utilization of hazardous
waste as a supplementary resource or for energy recovery, or after processing
und -tJilllei1 issued. by the Central Pollution Control Boar.
13 The authorization is subject to the conditions stated at Annexure "An enclosed with the
authorization letter and the such conditions as may be specified in the Rules for the time
being forced under the Environmental (Protection) Act, 1986.
14 The unit has to display and maintain the data online outside the factory main gate in Hindi
& English both on a 6'X 4' display board in the manner & format prescribed at Annexure
"B" and the report of the Compliance along with photograph shall be submitted to this
office & Regional Office, time to time.
15 That the annual reports/returns in the form prescribed under the Rules shall be
submitted to the Board by 30th June of every year and records of hazardous waste
Generation, handling & management shall be maintained according to the provisions of
the Hazardous Waste (Management, Handling and Transboundary Movement) Rules, 2008
and shown & submitted to the Board as and when asked for.
16 The hazardous waste should not be stored for a period beyond 90 days, failing which the
authorization shall deemed to be revoked.
Page 472
Rajasthan
RAJASTHAN STATE POLLUTION CONTROL BOARD
4, Institutional Area, Jhalana Doongari, Jaipur-302 004
Phone: 0141-5159600,5159695Fax: 0141-5159697
Revised Authorization
File No: F(HSW)/PaliOaitaran)/13(1)/2015-2016/1738-1740 Date:- 11/08/2015
Unit ld 59871
17 It shall be ensured that the Hazardous waste is handled, managed & disposed of strictly
in accordance with the Hazardous Waste (Management, Handling and Transboundary
Movement) Rules, 20Q8. Non- compliance of the Rules or any of the conditions contained
in 'the authorization shall be tantamount to automatic cancellation/revocation of the
authorization.
18 The operator of the facility shall liable to comply any other conditions as per the
guidelines isssued by the MoEF or CPCB or State Board related to collection, disposal,
reception, storage & treatment of hazardous waste.
19 That this revised authorization letter shall supercede the earlier authorization letter no
2015-2016/SWMC/HSW /51/1693-1695 dated 05/08/2015
20 That Authorization is issued under the provisions of Hazardous Waste
(Management ,Handling and Transboundary Movement) Rules, 2008 from the
environmental angle only, and does not absolve the project proponent from the
other statutory obligations prescribed under any other law or any other
instrument in force. The sole and complete responsibility, to comply with
conditions laid down in all other for the time-being in force,rests with the
industry/unit/project proponent.
21 That this Authorization shall not, in any way, adversely affect or jeopardize the legal
proceeding, if any, instituted in the past or that could be instituted againt you by the
State Board for violation of the provisions of the Act or the Rules-made thereunder.
This bears the approval of the competent authority.
Yours Sincerely
Group Incharge
CopyTo:-
1
2
cer, Regional Office, Rajasthan State Pollution Control B
Page 3 of 3
Page 473
,."
TERMS AND CONDITIONS OF AU'lrHORISATION
( I) The authorization shall comply with the provision of the Environment (Protection) Act, 1986 and the rules made
there under.
(2) The autr orization or its renewal shall be produced for inspection at the request of an officer authorized b) tht:
SpeB..
(3) The person authorized for hazardous waste management shall not rent, lend, sell transfer or otherwise transport the
hazardot s waste without obtaining prior permission of the spes.
(4) Ally una.nhorized change in personnel, equipment and working conditions as mentioned in the application b! the
person authorized shall constitute a breach of his authorization.
(5) It is duty of the authorized person to take prior permission of the spes before closing down the facility.
(6) An application tor the renewal of an authorization shall be made as laid down in Rule 5 (6) (ii).
(7) The occupier and operator of the authorized facility shall maintain records of its operations and send annua.
returns to the spes in the specified Form 4 respectively. '
nn Before transferring ownership or operation of a facility during its operating life. Or of a disposal facility dunng tht:
post closure care period, the owner or operator must seek prior permission of the spes and must notify the ne«
'occupier" or 'operator' in writing of the requirements of this authorization. The new occupier or operator sh,dl
comply with all applicable requirements of the authorization granted to the facility.
(9) Before an occupier or operator transports, Treats, stores, or disposes off any hazardous waste. Occupier or operator
of a facil ity must conduct a detai .ed physical and chemical analysis of a representative sample of the waste as per ,I
written waste analysis plan to be developed and followed by the Occupier or Operator of a facility and approved
by the S )CB. At the minimum, this waste analysis must contain all the information which must be known to treat.
store or dispose off the waste. At the minimum, the waste analysis plan must specify:
a. The parameters for which each hazardous waste will be analyzed and the rationale tor the selection of thexc
para meters.
h. The sampling method to obtain a representative sample of the waste to he analyzed,
c. The test method. which will be used to test these parameters.
d." The laboratory in which the analysis is to be carried out.
e. The frequency with which .he initial analysis of the waste will be reviewed or repeated to ensure thu: IhL
anal ysis is accurate and up :0 date. {The analysis must be repeated as necessary to ensure that it i~ al'('LII'~llL
and up to date. At the minimum, the analysis must be repeated. wherever there is a change in the procevs ",hi
opei ation generati ng the hazardous waste.)
(10) For off- site facilities, the occupier or operator must inspect and if necessary, analyze each hazardous c'. ,I,lL'
consignrient received at the facility to determine whether it matches with the identify of the waste specified on lhl
aCC0ll1p2nying manifest.
( II) Fhe occupier and operator must orevent t.nknown entry and minimize the possibil ity for the unauthorized elitr~ ,,;
persons or Iivestock onto the active portions of his (her) facility. There should be an appropriate ~4 I'PUI
surveillance system, a natural and artificial barrier surrounding the active portion or the facility, and a mean, (,.
control entry at all times through the gates. Signs with the legend "Danger- unauthorized personnel keep out" must
he posted at each entrance to active portion ofa facility. The legend must be written in English and inVernacul.a
Language predominant in the area surrounding the facility and must be legible from a distance of at least 10m.
(12) The occupier or operator must develop and maintain a written schedule for inspecting all monitoring equipment.
safety and emergency equipment, security devices and equipment that are important for preventing detecting or
responding to environmental or human health hazards, The schedule must identify the type of problems to look fOI
Juring the periodic inspection by the occupier/operator and frequency of inspection to each item of schedule. Th.
inspection details including date and time of inspection, name of the inspector. observations during inspection.
nature and details of any repairs or other remedial actions shall be recorded and such records shall be maintamcd
for at least 3 years.
(IJ) All the ticility personnel must be well informed about the hazardous waste management procedure relevant l') "c
positions in which they are ernp loyed. All the facility personnel must be trained to ensure that the) are ahlv l"
respond effectively to emergencies by familiarizing them with the emergency procedures. emergency cquipr tcr-t
operations and communication O!' alarm systems.
Page I of3
Page 474
:
i'(14) Facilities must be established, tasted periodically and maintained to minimize the possibility of a fire. explosion ur
any unplanned sudden or non-sudden re ease or hazardous waste to air, soil, sub surface or surface wa.er which
could threaten·human health or environment.
(IS) Wherever and whenever hazardous material is being handled, all personnel involved in the operation must have
immediate access to an internal alarm or emergency communication device, such a; a telephone capable of cal'ing
for external' assistance.
(16) The occupier or operator of'tbe facility must maintain aisle space to allow the unobstructed movement 01
personnel and equipments to any area of the facility in an emergency.
( 17) The occupier of operator of the facility must make arrangements, as appropriate for the type of waste handled at
the facility, .
a. To familiarize police, fire departments and emergency response terms with the layout of the facility, properties 01
hazardous waste handled at the facility and associated hazards and possible evacuation routes.
b. To familiarize local hospitals with the properties of hazardous waste handled and the type of injuries or iilnesses.
this could result from fires, explosions or releases at t~ facility.
(18) Each occupier or operator of the facility must develop, im olement, maintain and keep up to date, a contingency
plan designed to minimize impacts on human health or the environment from tires, explosions or any unplanned
sudden or non- sudden release of hazardous waste to air, soi, or water environment.
The contingency plan must include.
a. Arrangements agreed to by local police departments fire departments hospitals. State and local ernergencv
response terms to coordinate emergency services .
b. List of names, addresses and phone numbers elf all persons qualified to act as f mergency coordinator who is
responsible for all emergency response measures.
c. List of all emergency equipment at the facility, and
d. Evacuation plan for facility personnel where there is a possibility that evacuation could be necessary.
:r.r.ansportalion and reception of hazardous wastes:
( 19) An occupier or operator who transports or offers for transportation, hazardous wastes for off-site treatment.
storage or disposal, must prepare a manifest, in six copies, and must designate on the manifest one facility which j,
permitted to handle the waste described on the manifest. .
(20) The occupier/operator who offers the wastes for transportation must:
a. Sign the manifest certification by hand
b. Obtain hand-written signature of the transporter and the date of acceptance.
c. Retain one copy and send one copy to the SPCB, and
d. Give the remaining copies of the manifest to the transporter for necessary action a.s per manifest system.
(21) Before transporting of hazardous waste or offering hazardous waste for transportation off-site. the
occupier/operator must package the waste in accordance with the requirements in respect of packaging, labeling
and marking.
(22) An occupier/ operator shall not.offer for transport or receive hazardous wastes from a transporter who has not
received an authorization, for transport of hazardous wastes, from the SPCB.
(23) A transporter must not accept hazardous waste from a generator unless it is accompanied by a manifest signed h)
the generator. The transporter must sign and date the manifest acknowledging acceptance of the hazardous waste
from the generator and ensure that the manifest accompanies the hazardous waste.
(24) A transporter who delivers a hazardous waste to the designated facility, indicated in t.ie manifest. must obtain the
date of the delivery and handwritten signature of the operator of the designated facllity on the manifest. retain one
copy of the manifest for a period of three. years and give the remaining copies of the manifest to the designated
facility.
(25) In the event of an accident and discharge of hazardous waste during transportation. the transporter must take
appropriate immediate action to protect human health and the environment, (e.g. notify to SPCB. local police and
district administration, build a dyke to contain the discharge area) and must clean up the discharge as requirement
and approved by the State Board.
(26) If a facility receives hazardous waste accompanied by a manifest, the operator must Sign and date each copy of the
manifest to certify that the hazardous waste as per the manifest was received.
I]~RM.s.ANP CONDITIONS OF AUTHORISATION Page 2 of)
\ Page 475
.f-
«4) F.dH'i" must be ""bH,h,d, tasted periodi ca liy and m'i''''i,od to mi,imi", the ,o"ibi(ity of, fire "p(o,i,,,",
any unplanned sudden or non-sudden re ease or !!azardous waste to air, soil, sub sur/ace or surface wa.er whicl:could threaten'human health or environment.
(15) Wherever and whenever hazardous material is being handled, all personnel inval'led in the operation must ha, ~
immooi•••• cces to an im"",( alarm o"m""n",. 'ommoni,,,io, device, such a s a tel ephone capable or cal i;>,tor external' assistance.
(t 6) The o'''opi'' " operator or the f.dHty must main ta in aisle space '0 allow the onob","'''d rnovemem 01personnel and equipments to any area of the facility in an emergency.
( 17) The occupier of operator of the facility must make arrangements, as appropriate telr the type of waste handled althe facility, .
a. To familiarize police, fire departments and emergency response terms with the laycu: of the I'acility, properties ofhazardou's waste handled at the facility and associated hazards and possible evacua(i:ln routes.
b. To familiarize local hospitals with the properties of hazardous waste handled and the type of inj'uries or illnesses.this could result from fires, explosions or releases at the facility,
( 18) E.", ","pi" 00 operate- of the f,dlity must d'''iop, irn '(,m,m, main ta in and keep up <0 d.", a 'On'i"eo"
plan designed to minimize impacts on human health or the environment from tires, explosions or any unplanncdsudden or non- sudden release of hazardous waste to air, soi, or water environment.
The contingency plan must include.
a. Arrangements agreed to by local police departments tire departments hospitals. State and local emergen!:)response terms to coordinate emergency servic(!s
b. List of names, addresses and phone numbers of all pen:ons qualified to act as emergency Coordinator who isresponsible for all emergency response measures.
c. List of all emergency equipment at the facility, and
d. Evacuation plan for facility personnel where there is a possibility that evacuation could be necessary.Transportation and rece.Qtion of hazardous wastes:
( 19) An Occupier or operator who transports or offers for trar,sportation, hazardous wastes for off-site treatment.
storage or disposal, must prepare a manifest, in six copies, and must designate on the manifest one facility which i~permitted to handle the waste described on the manifest. .
(20) The occupier/operator who offers the wastes for transportation must:
a. Sign the manifest certification by hand
b. Obtain hand-written signature of the transporter and the date of acceptance.c. Retain one copy and send one copy to the SpeB, and
d. Give the remaining copies of the manifest to the t.ransporter for necessary action •.s per manifest system.
(21) Before transporting of hazardous waste or o::lering hazardous waste for transportation off-site. the
Occupier/operator must package the waste in accordance with the requirements in respect of packaging, labelingand marking.
(22) An occupier/ operator shall not .offe:' for transport or receive hazardous wastes from a transporter who has nO!received an authorization, for transport of hazardous wastes, from the Spe8.
(23) A .'n,pOt'" must OOf ""p' hazardous w,,,, froma , en crator unless it is "'Om"",,',d by a moo ifest signed h,
the generator. The transporter must sign and date the manifef.t acknowledging accept~nce of the hazardous \.\llstefrom the generator and ensure that the manifest accompanies the hazardous waste.
(24) A transporter who delivers a hazardous waste to the dt:signatt:d facility, indicated in tie manifest. must obtain the
date of the delivery and handwritten signature of the operator of the designated facilit:, On the manifest. retain one
copy of the manifest for a period of three years and give the remaining copies of the manifest to the designatedfacility.
(25) In the event of an accident and di.scharge of hazardous waste during transportatior:. the transporter must take
appropriate immediate action to protect human health and the enVironment, (e.g. nOlifj to spes. local police and
district administration, build a dyke to contain the discharge area) and must clean up the discharge as requirementand approved. by the: State Board.
(26) If a facility receives hazardous waste accompanied by a manifest, the operator must Sign and datc each copy ofthemanifest to certify that the hazardous waste as per the manifest was received.
IJ;:RMliND CQNQIT~.l\UTHQRISArrQN
Page 2 oD
Page 476
0. Record any significant discrepancy in the Mani'f-est.
b. Immediately give the transporter at lest one copy ofthe signed manifest.
c. Within 15 days from the elate of delivery send a copy of the signed manifest to the generator and 10 t!1I
speB/PCC.
d. Retain at the facility a copy of each manifest.
\27) Manifest discrepancies are dit]erences between the quantities or type of hazardous waste designated on lh,
munifes: and the quantity or type of hazardous waste a facility actually receives.
l2l{) If the gencrator/Sj'Clsss do not get back the signed manifest from the designed facility, generator has to bring till:'
to the notice of SPCBs and appropriate action has to be initiated by the SPCBs to identi fy and reel! t) the
deficiency. .
(29) A transporter should engage drivers, provided with special training for handling and transport of hazardous \-\astc-,
Vehicle; transporting the hazardous wastes and shall carry the Transport Emergency (TREM) card. In the event ,)1
accidental spillage during transport the instructions of the TREM card has to be followed.
(30) Driver t 'aining shall, at the minimum, include:
a. USE or the manifest system
b. Use of emergency equipment, such as fire extinguisher. gas mask, first aid etc.
c. Pro cedure to be followed in case of an emergency during transit
d. Use of TREM card
(31) [f the transporter cannot deliver the hazardous waste in accordance with the requirements he must contact tnl'
generator for further directions.
(32) The trar sporter should ensure that ignitable, reactive or non-compatible waste are not transported along With thl
other wsste, The transport vehicle should have proper lining cover, cushioning, shock absorbers etc.
!:!.bl-JD"'LNG1.ND STORAGE OF HAZARDCWS WASTES
(33) On-site .torage of the hazardous waste shall be permitted for a maximum period of 90 days, maximum quaruiu 01
10 tones or a truck load, whichever is less, unless otherwise specially permitted. 1t must be stored m .111
en vironrnentally sound manner i e., in isolated location away from the plant operational area.
(:l4) The off-site storage at a hazardo is waste treatment, storage and disposal facility shall be permitted for a mmnnum
period a; required for economics I and efficient treatment/disposal ofthe hazardous wastes.
(35) The storage facility should have an appropriate containment system as per the "Spill Prevention. COlltrol ,111<1
Counter Measures Plan", approved by the SPCS.
(:Ill) Each container holding hazardous wastes shall be marked "HAZARDOUS WASTE". in red color. both in I-.Ilglt~h.
Hindi and in Vernacular language (s)
(37) The occ rpier or operator must take precautions to prevent accidental ignition or reaction of ignitable ur reucu- ,.
wastes. Such waste must be separated and protected from sources of ignition or reaction including, but nOI limited
to. open names, smoking, cutting and welding, hot surfaces, frictional heat, water, sparks. radiant heal etc.
(38) The containment system in the storage area should be designed and operated to :
a. Have an underlying base free from cracks and sufficiently impervious to contain leachate any leaks, spill:, ·~k·
b. Dra nand remove liquids which may result from leak. spill or precipitation.
c. Contain at least 1-% of the volume ofcontainers or the largest container whichever is higher
d. "Run-on" into the containment system should be prevented
e. Have a slump or collection area to collect any leak, spill or precipitation and provision for immediate transfer
ot' tt e same to prevent overflow of the collection system.
(3'1) Hazardois wastes must not be placed in tanks for storage/treatment. Otherwise, it could cause the tank or its 1111!.!r
to rupture, leak, corrode and fail before the end of its intended life. Uncovered tanks must be operated to ensure .u
least 60 ern free board.
(40) The wase oil or spend/used oil will be sold/auctioned: only to the refiner having valid registration with tvlinlSI.'
of Environment and Forest Government cf India/Central Pollution Control Board, Delhi as actual user. He ,h(Juk!
also have valid authorization under Hazardous waste management rules and also consent under Air and Water /\,:1.
Issued fr om the related State Board.
Environmental Engillct'r (SW Me)
Page 477