SINGLETechnical Data BookBig Ceiling for Colombia (R410A, 60Hz, C/O)
Model : AC036KNCDKC/CB (ODU : AC036KXADKC/CB)
RemarkDateModificationVersion
Ver.1.0 Release SINGLE Big Ceiling for Colombia (R410A, 60Hz, C/O) TDB ’16.09.30.
History
(1) (2) (3) (4) (5) (6) (7) (8) Buyer
Nomenclature
Indoor Units
Model Names
AC CB036 K N C D K C
(1) ClassificationAC SINGLE
(2) Capacity
(3) Version
(4) Product Type
kBtu/h (3 digits)
F
H
J
2013
2014
2015
K 2016
N Indoor Unit
X Outdoor Unit
(5) Product Notation4 4Way Cassette S
N 4Way Cassette(600x600)
L
M
M
C
J
LSP Duct
MSP Duct
LSP Duct
Ceiling
Console
(6) FeatureF
P
D
S
Flagship
Premium
Deluxe
Standard
(7) Rating VoltageC
K
208~230V, 60Hz, 1Ф
220~240V, 50/60Hz, 1Ф
(8) ModeH
C
Heat Pump (R410A)
Cooling Only (R410A)
(1) (2) (3) (4) (5) (6) (7) (8) Buyer
Nomenclature
Outdoor Units
Model Names
AC CB036 K X A D K C
(1) ClassificationAC SINGLE
(2) Capacity
(3) Version
(4) Product Type
kBtu/h (3 digits)
F
H
J
2013
2014
2015
K 2016
N Indoor Unit
X Outdoor Unit
(5) Product NotationA INV+SIDE+General Temp.
B Non-INV+SIDE+General Temp.
4
C
4Way Cassette Only
Ceiling Only
(6) FeatureF
P
D
S
Flagship
Premium
Deluxe
Standard
(7) Rating VoltageE
K
G
220~240V, 50Hz, 1Ф
220~240V, 50/60Hz, 1Ф
380~415V, 50Hz, 3Ф
(8) ModeH
C
Heat Pump (R410A)
Cooling Only (R410A)
Contents
1 Specifications
2345678
Capacity tableDimensional drawing (Indoor)Electrical wiring diagram (Indoor)Sound pressure level (Indoor)Temperature and air flow distribution (Indoor)Electrical wiring diagram (Outdoor)Sound pressure level (Outdoor)
91011
Piping diagram (Outdoor)Dimensional drawing (Outdoor)Capacity correction (Outdoor)
SpecificationsBig Ceiling
1
NOTE
* Specifications may be subject to change without prior notice.1) Nominal capacity are based on ( Refrigerant Piping : 5m(16.4ft), Level Differences : 0m(0ft) ); . Cooling : Indoor temp. 27ºC DB, 19ºC WB (80.6ºF DB, 66.2ºF WB) / Outdoor temp. 35ºC DB, 24ºC WB (95ºF DB, 75.2ºF WB) . Heating : Indoor temp. 20ºC DB, 15ºC WB (68°F DB, 59°F WB) / Outdoor temp. 7ºC DB, 6ºC WB (44.6°F DB, 42.8°F WB)2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.3) These products contain R410A which is fluorinated greenhouse gas.
Big CeilingAC036KNCDKC/CBAC036KXADKC/CB
- COOLING ONLYkW 2.73 / 9.82 / 11.14
Btu/h 9,300 / 33,500 / 38,000US RT 0.78 / 2.79 / 3.17
kW -Btu/h -US RT -
0.65 / 3.30 / 4.70-
4.00 / 16.00 / 21.50-
A 26.7A 30- 2.98
(Btu/h)/W 10.15- -
Energy Grade (C) EEnergy Grade (H) -
Φ, mm 9.52Φ, inch 3/8"Φ, mm 15.88Φ, inch 5/8"
m 50ft 164m 30ft 98- -- 0.75 ~ 1.25- R410A- -kg 1.5lbs 3.31
Φ, #, V, Hz 1,2,220-240,60- Sirroco
Output x n W 153 x 1CMM 26.00 / 23.00 / 19.00CFM 918 / 812 / 671
Min / Std / Max mmAq -Drain Φ,mm VP25 (OD 32,ID 25)
High / Mid / Low 48 / 44 / 40Cooling -
kg 33.0lbs 72.75kg 39.0lbs 85.98mm 1,350 x 235 x 675inch 53.15 x 9.25 x 26.57mm 1,439 x 321 x 758inch 56.65 x 12.64 x 29.84
- -kg -lbskg -lbsmm -inchmm -inch
- -mm/liter/h -
Air Filter - -Φ, #, V, Hz 1,2,220-240,60
- Tw in BLDC Rotary- UG8T300FUBJU
kW 2.82Oil - PVE
CMM 50.00CFM 1,766
Cooling 52Cooling -
kg 62.0lbs 136.69kg 66.0lbs 145.51mm 880 x 967 x 320inch 34.65 x 38.07 x 12.60mm 1,047 x 1,045 x 415inch 41.22 x 41.14 x 16.34ºC -15~50ºF 5 ~ 122ºC -ºF -
dB(A)Sound Pow er Level
ExternalDimension
Net Weight
Shipping Weight
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
OutdoorUnit
Pow er Supply
Compressor
TypeModelOutput
Type
Fan Air Flow Rate Cooling
Sound DataSound Pressure Level
OperatingTemp. Range
Cooling
Heating
Shipping Dimensions (W×H×D)
AdditionalAccessories
Drain pumpDrain pumpMax. Lifting Height / Displacement
dB(A)Sound Pow er Level
ExternalDimension
Net Weight
Shipping Weight
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
IndoorUnit
Pow er Supply
Fan
TypeMotor
Air Flow Rate High / Mid / Low
External Static PressureDrain Pipe
Sound DataSound Pressure Level
Panel Size
Panel model
Panel Net Weight
Shipping Weight
Net Dimensions (W×H×D)
FieldWiring
Pow er Source WireTransmission Cable
Refrigerant
TypeControl Method
Factory Charging
PipingConnections
Liquid Pipe
Gas Pipe
InstallationLimitation
Max. Length (Outdoor to indoor)
Max. Height (Betw een ID/OD)
EnergyEfficiency
EER (Nominal Cooling)EER (Nominal Cooling, US)COP (Nominal Heating)
Energy Grade
Cooling (Min / Std / Max)A
Heating (Min / Std / Max)MCAMFA
Type
Model NameIndoor UnitOutdoor Unit
System
Mode
Capacity
Cooling (Min / Std / Max)
Heating (Min / Std / Max)
Pow er
Pow er Input(Nominal)
Cooling (Min / Std / Max)kW
Heating (Min / Std / Max)Current Input(Nominal)
Capacity tableBig CeilingAC036JNCDKC/CB + AC036JXADKC/CB
Cooling TC(Total Capacity), SHC(Sensible Heat Capacity), PI(Power Input)
* Capacity table may be subject to change without prior notice.
1) Capacities are based on following conditions;
. Refrigerant piping length : 5m(16.4ft) / Level difference : 0m(0ft).
2
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 33.30 26.60 1.58 34.10 27.30 1.62 34.90 28.00 1.66 35.80 28.60 1.70 36.25 28.95 1.72 36.70 29.30 1.74 37.50 30.00 1.78
21 38.10 30.50 2.67 39.10 31.20 2.73 40.00 32.00 2.80 41.00 32.80 2.87 41.50 33.20 2.91 42.00 33.60 2.94 43.00 34.40 3.01
35 32.50 26.00 3.14 33.30 26.70 3.22 34.20 27.30 3.30 33.50 25.80 3.30 35.40 28.35 3.42 35.80 28.70 3.46 36.70 29.40 3.54
43 25.70 20.50 2.98 26.30 21.00 3.05 26.90 21.60 3.13 27.60 22.10 3.20 27.95 22.35 3.24 28.30 22.60 3.28 28.90 23.20 3.36
50 18.20 14.60 2.57 18.70 14.90 2.63 19.10 15.30 2.69 19.60 15.70 2.76 19.85 15.90 2.80 20.10 16.10 2.83 20.60 16.40 2.89
14 (WB) 16 (WB) 18 (WB) 19 (WB) 20 (WB) 22 (WB) 24 (WB)Outdoor
temperature(ºC, DB)
Indoor temperature (ºC)
20 (DB) 22 (DB) 25 (DB) 27 (DB) 28 (DB) 30 (DB) 32 (DB)
Electrical wiring diagramBig Ceiling
4
AC036KNCDKC/CB
NOTE1. This wiring diagram applies only to the indoor unit.2. Symbols show as follow; BLK : black, RED : red, BLU : blue, WHT:white, YEL : yellow, BRN : brown, SKY : sky-blue, GRN : green3. For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remotecontroller transmission F3-F4.4. Protective earth(screw)
Sound Pressure LevelBig Ceiling
Unit: dB(A)
Model
AC036KNCDKC/CB (ODU : AC036KXADKC/CB)
NoteSpecifications may be subject to change without prior notice.Sound pressure level is obtained in an anechoic room.Sound pressure level is a relative value, depending on the distance and acoustic environment.Sound pressure level may differ depending on operation condition.dBA = A-weighted sound pressure levelReference acoustic pressure 0 dB= 20 uPa
NC curve1) AC036KNCDKC/CB (ODU : AC036KXADKC/CB)
5
High Low
48 40
63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz)
10
15
20
25
30
35
40
45
50
55
Sou
nd p
ress
ure
leve
l(dB
)
Temperature and air flow distributionBig CeilingAC036KNCDKC/CB
(1) Cooling air velocity distribution Discharge angle (Default) : 32º
(2) Cooling Temperature distribution Discharge angle (Default) : 32º
6
Electrical wiring diagramOutdoor unit
7
AC036KXADKC/CB
NOTE1. This wiring diagram applies only to the outdoor unit.2. Symbols show as follow; BLK : black, RED : red, BLU : blue, WHT:white, YEL : yellow, BRN : brown, SKY : sky-blue, GRN : green3. For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remotecontroller transmission F3-F4.4. Protective earth(screw)
Sound Pressure LevelOutdoor unit
Unit: dB(A)
Model
AC036KXADKC/CB (IDU : AC036KNCDKC/CB)
NoteSpecifications may be subject to change without prior notice.Sound pressure level is obtained in an anechoic room.Sound pressure level is a relative value, depending on the distance and acoustic environment.Sound pressure level may differ depending on operation condition.dBA = A-weighted sound pressure levelReference acoustic pressure 0 dB= 20 uPa
NC curve1) AC036KXADKC/CB (IDU : AC036KNCDKC/CB)
8
Cooling
52
1.5m
1m
Front
Microphone
63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz)
20
25
30
35
40
45
50
55
60
Sou
nd p
ress
ure
leve
l(dB
)
Piping diagramOutdoor unit
9
AC036KXADKC/CB
Electronic ExpansionValve - Main
(E_M)
ThermistorCond Out(T_CO)
OutdoorFan
Motor 1(OFM1)
ThermistorAmbient(T_A)
Heat ExchangerIndoor Unit (HX_ID)
Indoor Fan Motor(IFM)
AC036KNCDKC/CB
Model
15.88(5/8")
Service Valve - Gas pipe(SV_G)
Service Valve - Liquid pipe(SV_L)
HeatExchanger
Main(HX_M)
ThermistorIndoor Room
(T_IR)Thermistor
IDUheat
exchangerMid
(T_IM)
ThermistorIDUheat
exchanger In(T_II)
Indoor UnitOutdoor Unit
Liquid pipeconnection port
Ø A
Gas pipeconnection port
Ø B
9.52(3/8")
ThermistorDischarge
pipe(T_D)
Compressor(COMP)
A B
Filter
Thermistor Compressor
Top(T_CT)
Dimensional drawingOutdoor unitAC036KXADKC/CB
10
Units : mm / inches
Table of descriptions1 Refrigerant gas pipe 7
2 Refrigerant liquid pipe 8
3 Power & Comm. wiring conduits 9
4 10
5 11
6 12
880 [2'-10 3/4"]
645[2'-1 1/2"]
125[5"]
364
[1'-2
1/4
"]
340
[1'-1
1/2
"]
52 [2"]
101
[4"]
12 [1/2"]
578[1'-10 3/4"]
965
[3'-2
"]
503
[1'-7
3/4
"]
128
[5"]
70 [2
3/4
"]
320[1'-0 1/2"]
Capacity correctionOutdoor unitAC036KNCDKC/CB + AC036KXADKC/CB
Cooling
11
Pipe Length (m)5 10 15 20 25 30 35 40 45 50
Leve
l Diff
eren
ce (m
)
302520151050-5
-10-15-20-25-30
-----
1.001.001.00
-----
----
0.990.990.990.980.98
----
---
0.970.970.970.970.960.960.96
---
--
0.960.960.960.960.960.950.950.950.94
--
-0.950.950.950.950.950.950.940.940.930.930.93
-
0.940.940.940.940.940.940.940.940.940.930.930.930.92
0.920.920.920.920.920.920.920.920.920.910.910.910.90
0.910.910.910.910.910.910.910.910.910.900.900.890.89
0.890.890.890.890.890.890.890.890.870.870.870.860.86
0.870.870.870.870.870.870.870.870.870.860.860.850.85
2016. 09. Ver. 1.0
Samsung Electronics Co., LTD.B2B PM / SEHead Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677Website : www.samsung.com btsp.samsunggsbn.com Email : [email protected] and data in this book may subject to change without prior notice.