Small Battery Drive. For orthopaedic trauma applications. Ergonomic, lightweight design Compatible with a wide variety of attachments Variable speed trigger with instant reverse and oscillation
Transcript
Page 1: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

Small Battery Drive. For orthopaedictrauma applications.

Ergonomic, lightweight design

Compatible with a wide variety ofattachments

Variable speed trigger with instant reverse and oscillation

Page 2: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery
Page 3: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

Synthes 1

Small Battery Drive. For orthopaedic trauma applications.

The Small Battery Drive (532.010) is indicated for most orthopaedic trauma applications, including drilling, sawing,inserting K-wires, DHS, DCS and intramedullary reaming. Optimal performance can be achieved by selecting the appropriate battery for the specific application.

Features– Ergonomic, lightweight design

– Batteries retain life longer than autoclaved batteries

– Two battery sizes for wider range of indications

– Compatible with a wide variety of attachments

– Fully cannulated to 3.2 mm

– Variable speed trigger with instant reverse and oscillation

Specifications– Variable speed: 0–3,840 rpm

(max. speed varies by attachment)

– Maximum torque: 0–6.0 Nm (max. torque varies by attachment)

– Weight, including 12 V battery: 810 grams, including 14.4 V battery: 916 grams

– Cannulation: 3.2 mm

Specifications for batteries– Capacity: 0.5 Amp hours

– Type: NiCd

– Working temperature: 0°C to 50°C (32°F to 122°F)

– Discharge protection: prevents total battery discharge, significantly decreases memory effect, maintains battery capacity, and increases battery life

532.010

Battery Casing(532.002)

Mode switch turnsdrive off for safe attachment exchangeand selects “on” or“oscillation” mode

Page 4: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

12 V Battery (532.003)– Voltage: 12 VDC

– Charging time: 30 minutes maximum

– Indications include drilling, sawing,and inserting K-wires

14.4 V Battery (532.033)– Voltage: 14.4 VDC

– Charging time: 40 minutes maximum

– Indications include DHS, DCS, and intramedullary reaming

2 Synthes Small Battery Drive

Small Battery Drive. For orthopaedic trauma applications.

Sawing Drilling K-wire insertion

Reaming

Page 5: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

Small Battery Drive Synthes 3

Attachments for Small Battery Drive

532.011 Mini Quick Coupling

532.012 Stryker J-Latch Coupling

With 12 V battery:

Maximum speed: 3,200 rpm

Maximum torque: 0.5 Nm

With 14.4 V battery:

Maximum speed: 3,840 rpm

Maximum torque: 0.6 Nm

Accepts mini quick coupling or Stryker J-Latch drill bits

532.022 Quick Coupling for K-Wires

Cannulation: 3.2 mm (fully open)

With 12 V battery:

Maximum speed: 800 rpm

Maximum torque: 3.0 Nm

With 14.4 V battery:

Maximum speed: 900 rpm

Maximum torque: 2.3 Nm

To insert / remove Kirschner wires and guidepins 0.6 mm–3.2 mm in diameter (any length)

05.001.250 AO Quick Coupling for Drill Bits

Cannulation: 2.1 mm

Accepts cutting tools and instruments withthe AO quick coupling fitting

05.001.252 Small Chuck with Key

Cannulation: 3.3 mm

Accepts round and triangular shafts: up to 4.5 mm

* Performance specifications on file at Synthes.

Drilling speed attachments

The following drilling speed attachments are geared for amaximum drive speed of 1,200 rpm with the 12 V battery and 1,440 rpm with the 14.4 V battery. The maximum torque is 1.3 Nm with the 12 V battery and 1.6 Nm with the 14.4 V battery.*

Page 6: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

4 Synthes Small Battery Drive

05.001.253 Large Chuck with Key Cannulation: 3.3 mm

Accepts round and triangular shafts: up to 7.3 mm

* Performance specification on file at Synthes.

05.001.251 AO Screw Attachment Cannulation: 2.0 mm Accepts AO coupling screwdriver

The following reaming speed attachments are geared for a maximum speed of 384 rpm and a maximum torque of 6.0 Nm with the 14.4 V battery.* All reduction drive units allow intramedullary reaming with most IM nail systems.

Note: The reaming speed attachments should only be usedwith the 14.4 V battery for optimal performance.

Reaming speed attachments

Attachments for Small Battery Drive

Drilling speed attachments continued

Saw attachments

532.023 Oscillating Saw Attachment II

Maximum speed: With 12 V battery=

15,000 oscillations per minute

With 14.4 V battery= 18,000 oscillations per minute

532.026 Oscillating Saw Attachment, large

Maximum speed: With 12 V battery=

15,000 oscillations per minute

With 14.4 V battery= 18,000 oscillations per minute

532.021 Sagittal Saw Attachment

Maximum speed: With 12 V battery= 15,000 oscillations per minute

With 14.4 V battery= 18,000 oscillations per minute

Page 7: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

Small Battery Drive Synthes 5

05.001.254 Chuck with Key Cannulation: 3.2 mm Accepts round and triangular shafts:

up to 7.3 mm

532.015 Large Quick Coupling

Cannulation: 3.2 mm

Accepts DHS and DCS triple reamers, screwdriver shafts and cannulated drill bitswith large quick coupling fitting

532.017 AO Reduction Drive Unit

Cannulation: 3.2 mm

Accepts cutting tools and instruments withAO reaming fitting

532.018 Hudson Reduction Drive Unit

Cannulation: 3.2 mm

Accepts cutting tools and instruments withHudson fitting

532.019 Trinkle Reduction Drive Unit

Cannulation: 3.2 mm

Accepts cutting tools and instruments withTrinkle fitting

532.020 Modified Trinkle Reduction Drive Unit

Cannulation: 3.2 mm

Accepts cutting tools and instruments withmodified Trinkle fitting

Page 8: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

6 Synthes Small Battery Drive

Battery Pack Assembly

Batteries and battery charger– Advanced battery technology and

nonautoclavable batteries prevent total battery discharge, significantlydecrease memory effect, maintainbattery capacity, and increase battery life

– One battery charger for all Synthespower equipment batteries simplifiescharging process

– Intuitive assembly of battery pack

Battery pack assembly– Allows use of nonsterile batteries

to increase battery life

– Encloses battery within sterile field

Scrubbed person1 Hold the sterilized battery casing

and open the lid.

2 Place the sterilized battery insertionshield on the battery casing.

Circulating person3 Carefully insert the nonsterile battery

into the sterile battery casing.

4 Press firmly until it engages.

5 Remove the battery insertion shield.

Scrubbed person6 Close and lock the lid.

1 2

3 4

5

Circulatingperson

Circulatingperson

Scrubbed person

Scrubbed person

Scrubbed person

Scrubbed person

Scrubbed person

Circulatingperson

Page 9: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

Small Battery Drive Synthes 7

Small Battery Drive Set (105.955)

Graphic Case60.550.010 Base Assembly for Small Battery Drive

Graphic Case

60.550.011 Lid for Small Battery Drive Graphic Case

60.550.012 Attachment Rack for Small Battery DriveGraphic Case

60.550.013 Insert Tray for 12 V Battery Casings

60.550.016 Insert Tray for Small Battery Drive Handpiece and Radiolucent Drive

Instruments05.001.250 AO Quick Coupling for Drill Bits

05.001.253 Large Chuck with Key, Drilling Speed

05.001.204 Universal Battery Charger II

532.002 Battery Casing, for 12 V Battery, 2 ea.

532.003 Small Battery Drive 12 V Battery, 2 ea.

532.004 Battery Insertion Shield, 2 ea.

532.010 Small Battery Drive

532.011 Mini Quick Coupling

532.012 Stryker J-Latch Coupling

532.015 Large Quick Coupling

532.021 Sagittal Saw Attachment

532.022 Quick Coupling for K-Wires

60.550.013

60.550.010, 60.550.011 and 60.550.012

60.550.016

Page 10: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

8 Synthes Small Battery Drive

Graphic Case60.550.010 Base Assembly for Small Battery Drive

Graphic Case

60.550.011 Lid for Small Battery Drive Graphic Case

60.550.012 Attachment Rack for Small Battery Drive Graphic Case

60.550.013 Insert Tray for 12 V Battery Casings

60.550.014 Insert Tray for 14.4 V Battery Casings

60.550.016 Insert Tray for Small Battery Drive Handpiece and Radiolucent Drive

Instruments05.001.250 AO Quick Coupling for Drill Bits

05.001.253 Large Chuck with Key, Drilling Speed

05.001.204 Universal Battery Charger II

532.002 Battery Casing, for 12 V Battery, 2 ea.

532.003 Small Battery Drive 12 V Battery, 2 ea.

532.004 Battery Insertion Shield, 2 ea.

532.010 Small Battery Drive

532.011 Mini Quick Coupling

532.012 Stryker J-Latch Coupling

532.015 Large Quick Coupling

532.017 AO Reduction Drive

532.021 Sagittal Saw Attachment

532.022 Quick Coupling for K-Wires

532.031 Adaptor for Radiolucent Drive

532.032 Small Battery Drive Casing, for 14.4 V Battery, 2 ea.

532.033 Small Battery Drive 14.4 V Battery, 2 ea.

Small Battery Drive with 14.4 V Battery Pack Set (105.954)

60.550.01460.550.013

60.550.010, 60.550.011 and 60.550.012

60.550.016

Page 11: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

Small Battery Drive Synthes 9

511.30

Instruments05.001.108 Light Adaptor for Small Battery Drive, for Electric Pen Drive

05.001.251 AO Screw Attachment

05.001.252 Small Chuck with Key, Drilling Speed

05.001.254 Large Chuck with Key, Reaming Speed

310.93K Replacement Key for Small Chuck with Key(05.001.252)

510.19 Replacement Key for Large Chucks(05.001.253 and 05.001.254)

511.30 Radiolucent Drive

519.40 Cleaning Brush

519.97 Autoclavable Oil

532.023 Oscillating Saw Attachment II

532.026 Oscillating Saw Attachment, large

532.018 Hudson Reduction Drive Unit

532.019 Trinkle Reduction Drive Unit

532.020 Modified Trinkle Reduction Drive Unit

Graphic Case60.550.015 Insert Tray for Small Battery Drive Adaptor

for Electric Pen Drive60.550.017 Insert Tray for Two Small Battery Drive

Handpieces60.550.018 Label Sheet for Small Battery Drive Set

Attachment Rack

690.525 Small Graphic Case for Small Battery Drive Set

690.576.04 Grommets for Attachment Rack for Small Battery Drive Graphic Case, 4 pack

Service and Extended Warranty ProgramsW1.105.955 One-Year Extended Warranty and Service

Program, for Small Battery Drive Set

W3.105.955 Three-Year Extended Warranty and ServiceProgram, for Small Battery Drive Set

Also Available

05.001.252

Page 12: Small Battery Drive. For orthopaedic trauma applications.synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes...Small Battery Drive. For orthopaedic trauma applications. The Small Battery

Synthes Anspach4500 Riverside DrivePalm Beach Gardens, FL 33410Telephone: (561) 627-1080To order: (800) 327-6887Fax: (800) 327-6661E-mail: [email protected]

Synthes (Canada) Ltd.2566 Meadowpine BoulevardMississauga, Ontario L5N 6P9Telephone: (905) 567-0440To order: (800) 668-1119Fax: (905) 567-3185

www.synthes.comwww.anspach.com

© 2002 Synthes, Inc. or its affiliates. All rights reserved. DCS, DHS and Synthes are trademarks of Synthes, Inc. or its affiliates. Printed in U.S.A. 1/12 J3992-F


Recommended