ENERGY SYSTEMS ® Contents Actual Situation Page 2 Our Ambition Page 3 aeteba Solar-Cooling-System Page 4 Possible Applications Page 5 Charts Page 6 Questionnaire Page 11 Solar cooling Save energy Reduce costs Raise yield
Transcript

ENERGY SYSTEMS

®

Contents

Actual Situation Page 2

Our Ambition Page 3

aeteba Solar-Cooling-System Page 4

Possible Applications Page 5

Charts Page 6

Questionnaire Page 11

Solar coolingSave energy

Reduce costs

Raise yield

2

ENERGY SYSTEMS

®

Actual situation

• Tremendously rising prices for primary energy

• Worldwide increasing CO2 emission

• Limited resources

• Statutory provisions concerning energy saving

3

ENERGY SYSTEMS

®

Our Ambition

• To reduce running costs

• To reduce CO2 emission

• To prevent resources

• To capitalize sensibly on available energy

4

ENERGY SYSTEMS

®

The aeteba Solar-Cooling-SystemProduction of 340 kW renewable Energy with only 6 kW conventional energy

400 m² of solar collectors is needed

to produce of 100 kW cooling capacity.

At the same time there is an output of 240kW heating capacity.

All this renewable energy can be produced with only 6 kW conventional energy.

5

ENERGY SYSTEMS

®

Possible applications

• Office and administration buildings

• Hotels, particularly those with SPAs

• Indoor swimming pools

• Gymnasiums, fitness centres

• Production buildings

• Malls and stores

• And Other fields of application

6

ENERGY SYSTEMS

®

Benefits of aeteba Solar-Cooling-Systems

• Triple system utilization: hot water, heating, cooling

• Low operating costs

• Active environmental protection through reduced CO2 emission

• Proven technology

• Long service life of major components

Phase match of cooling need and insolation.

The chart points out clearly that at high solar irridation there is a high need for cooling.

Globale Einstrahlung - Global insolation

Kühlbedarf - Need for cooling

Heizbedarf - Need for heating

Mrz - Mar

Mai - May

Okt - Oct

Dez - Dec

7

ENERGY SYSTEMS

®

Comparison of production costs of energy (both warmth and cooling energy)

The represented costscontain only the costs forthe energy-sources.

All effective energy in aeteba Solar-Cooling-System is provided by thesun.

Pumps are only needed forthe distribution of theenergy flux.

This is why warmth an coldis produced at unbeatablelow costs.

20,0 Cent/kWh

17,1 Cent/kWh

0,5 Cent/kWh

0,0

5,0

10,0

15,0

20,0

25,0

Period

of

20 Y

ears

Specific

energ

ycosts

Cent/kW

h

Compressionchiller

COP 2,75

+

Boiler

Efficiency 0,85

Heat pump

COP 4

+

Boiler

Efficiency 0,85

aeteba-system

8

ENERGY SYSTEMS

®

Saving of energy-costs over 20 years

Compared aeteba Solar-Cooling-System and conventional technologiesthere is a cost cuttingalready in the first year.

The average cost savingover 20 years is about53.000,- € per year.

- €

200.000 €

400.000 €

600.000 €

800.000 €

1.000.000 €

1.200.000 €

1.400.000 €

1.600.000 €

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Re

turn

s in

Years

9

ENERGY SYSTEMS

®

Amortization of invest

The investment costs areamortized within about 7 years.

-250.000 €

-200.000 €

-150.000 €

-100.000 €

-50.000 €

- €

50.000 €

100.000 €

1 2 3 4 5 6 7 8 9

Re

turn

s in

Years

10

ENERGY SYSTEMS

®

aeteba GmbH

An der Alten Spinnerei 1

D - 83059 Kolbermoor

Telephone +49 8031 _ 8091300

Fax +49 8031 _ 8091318

E-mail [email protected]

www.aeteba.de

CEO Günter Kimmig

Handelsregister B Traunstein HRB 17721

Do you want to learn more about solar cooling?

Please call us, we will be happy to provide you with

more information.

Together, we will dive deeply into the pool of

technical possibilities.

11

ENERGY SYSTEMS

®

Questionnaire

Bases for calculation

→ FAX +49 (8031) 80913-18

For a first and short estimate of your personnal savings please fill in this form:

Kind of building/Adress: ____________________________________________________

Floor space: _______ m²

Available space for collectors: □ Gable roof □ Flat roof □ open air ground

Energy source: □ Fuel □ Gas □ PowerPrice: ___ €/kWh ___ €/kWh ___ €/kWh

NeedHeating ___ kWCooling ___ kW