10001 BID Project No. 134-18 Woodville Tompkins HS Additions School Code 625-1605 Savannah-Chatham County Schools, Georgia Volume II of II October 9 th , 2019 P R O J E C T M A N U A L James W. Buckley & Associates, Inc. 7 East Congress Street, Suite 800 Savannah, Georgia 31401 Phone: (912) 447-1080 Fax: (912) 447-1060 Set No.
Transcript
  • 13

    10001

    BID Project No. 134-18

    Woodville Tompkins HS Additions School Code 625-1605

    Savannah-Chatham County Schools, Georgia Volume II of II October 9th, 2019

    P R O J E C T M A N U A L

    James W. Buckley & Associates, Inc. 7 East Congress Street, Suite 800

    Savannah, Georgia 31401 Phone: (912) 447-1080 Fax: (912) 447-1060

    Set No.

  • P R O J E C T M A N U A L F O R

    Woodville Tompkins HS Additions

    Chatham County, GA

    OWNER:

    Savannah- Chatham County Public School System

    208 Bull Street

    Savannah, Georgia 31401

    (912) 395-5600

    Fax: (912) 201-7648

    ARCHITECTS:

    James W. Buckley & Associates, Inc.

    7 East Congress Street, Suite 800

    Savannah, Georgia 31401

    (912) 447-1080

    Fax (912) 447-1060

    STRUCTURAL ENGINEER:

    Saussy Engineering.

    400E Johnny Mercer Blvd.

    P.O. Box 30597

    Savannah, Georgia 31410

    (912) 898-8255

    Fax (912) 898-1882

    MECHANICAL AND ELECTRICAL ENGINEER:

    Dulohery Weeks

    333 Commercial Drive

    Savannah, Georgia 31406

    (912) 355-0235

    Sustainable Design

    Warren R. Law P.E

    118 Palmetto Drive

    Rincon, Georgia 31326

    (912) 660-9079

    Project No. 127-17

    © 2019 James W. Buckley & Associates, Inc.

  • T A B L E O F C O N T E N T S

    Savannah Chatham County Public School System

    Woodville Tompkins HS Additions School Code 625-1605

    THE CONTRACTOR IS REQUIRED TO COMPARE THIS PROJECT MANUAL WITH THE INDEX

    BELOW FOR COMPLETENESS. IF ANY PAGES ARE MISSING OR ILLEGIBLE, IT IS HIS

    RESPONSIBILITY TO REQUEST REPLACEMENTS FROM THE ARCHITECT.

    VOLUME II of II

    DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

    SAMPLE SCCPSS SOLICITATION DOCUMENTS

    SAMPLE SCCPSS CONSTRUCTION CONTRACT AND GENERAL CONDITIONS

    DIVISION 01 - GENERAL REQUIREMENTS

    01 1000 SUMMARY

    01 2200 UNIT PRICES

    01 2300 ALTERNATES

    01 2500 SUBSTITUTION PROCEDURES

    01 2500.10 PRODUCTION SUBSTITUTION CHECKLIST

    01 2500.15 SUBSTITUTION REQUEST (Pre-Bid)

    01 2500.20 SUBSTITUTION REQUEST (Post-Bid)

    01 2600 CONTRACT MODIFICATION PROCEDURES

    01 3100 PROJECT MANAGEMENT AND COORDINATION

    01 3200 CONSTRUCTION PROGRESS DOCUMENTATION

    01 3300 SUBMITTAL PROCEDURES

    01 3300.10 SUBMITTAL TRANSMITTAL

    01 4000 QUALITY REQUIREMENTS

    01 4100 REGULATORY REQUIREMENTS

    01 4100.01 NOTICE OF COMMEMCEMENT

    01 4100.02 CONTRACTOR AFFADAVIT

    01 4100.03 SUBCONTRACTOR AFFIDAVIT

    01 4100.04

    01 4100.05

    SUB CONTRACTOR AFFIDAVIT

    CHAPTER 17 SPECIAL INSPECTIONS

    01 5000 TEMPORARY FACILITIES AND CONTROLS

    01 6000 PRODUCT REQUIREMENTS

    01 6000.10 FORM CERTIFICATE OF MANUFACTURER

    01 6000.12 WARRANTY OF GENERAL CONTRACTOR

    01 6000.14 WARRANTY BY SUBCONTRACTOR TO GENERAL CONTRACTOR

  • 01 6000.16 SPECIAL EXTENDED WARRANTY

    01 6000.18 HAZARDOUS MATERIALS CERTIFICATE

    01 7300 EXECUTION

    01 7700 CLOSEOUT PROCEDURES

    01 7823 OPERATION AND MAINTENANCE DATA

    01 7839 PROJECT RECORD DOCUMENTS

    01 7900 DEMONSTRATION AND TRAINING

    DIVISION 02 - EXISTING CONDITIONS

    02 0600 GEOTECHNICAL DATA AND REPORT

    02 2210 BUILDING DEMOLITION

    DIVISION 03 - CONCRETE

    03 3000 CAST-IN-PLACE CONCRETE

    03 5110 CEMENTITIOUS WOOD-FIBER DECK

    03 5216 LIGHTWEIGHT INSULATING CONCRETE

    DIVISION 04 - MASONRY

    04 2000 UNIT MASONRY ASSEMBLIES

    DIVISION 05 - METALS

    05 1200

    05 2200

    STRUCTURAL STEEL

    STEEL JOIST

    05 4000 COLD-FORMED METAL FRAMING

    05 5010 METAL FABRICATIONS

    05 5130

    05 5150

    ALUMINUM PIPE RAILINGS

    EXTERIOR.FIXED WALL LADDERS

    DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

    06 1053 MISCELLANEOUS ROUGH CARPENTRY

    06 1600 SHEATHING

    06 2020 FINISH CARPENTRY

    06 4110 ARCHITECTURAL WOODWORK

    DIVISION 07 - THERMAL AND MOISTURE PROTECTION

    07 1500 VAPOR BARRIERS

    07 1613 POLYMER MODIFIED CEMENT WATERPROOFING

    07 2100

    07 2419

    BUILDING INSULATION

    EXTERIOR INSULATION AND FINISH SYSTEM

    07 2726 FLUID-APPLIED MEMBRANE AIR BARRIERS

    07 4011

    07 4100

    METAL ROOF & WALL PANELS

    BITUMINOUS DAMPPROOFING

    07 5410 POLYVINYL-CHLORIDE (PVC) ROOFING

  • 07 7100

    07 7200

    MANUFACTURED ROOF SPECIALTIES

    ROOF ACCESSORIES

    07 8410 THROUGH-PENETRATION FIRESTOP SYSTEMS

    07 9200 JOINT SEALERS

    07 9513 EXPANSION JOINT COVER ASSEMBLIES

    DIVISION 08 - OPENINGS

    08 1113 HOLLOW METAL DOORS AND FRAMES

    08 1416

    08 3050

    08 3325

    FLUSH WOOD DOORS

    ACCESS DOORS

    COILING COUNTER DOORS

    08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

    08 4413 GLAZED ALUMINUM CURTAIN WALLS

    08 7100 DOOR HARDWARE

    08 8000

    08 8300

    08 8813

    GLAZING

    MIRRORS

    FIRE RESISTANT GLAZING

    DIVISION 09 - FINISHES

    09 2216

    09 2226

    NON-STRUCTURAL METAL FRAMING

    DRYWALL GRID SYSTEMS

    09 2900 GYPSUM BOARD

    09 3000 TILING

    09 5100 ACOUSTICAL CEILINGS

    09 6400 WOOD FLOORING

    09 6420 ATHLETIC WOOD FLOORING

    09 6513 RESILIENT BASE AND ACCESSORIES

    09 6519

    09 6566

    RESILIENT TILE FLOORING

    RESILIENT ATHLETIC FLOORING

    09 6810

    09 8400

    09 8413

    CARPETING

    ACOUSTIC ROOM COMPONENTS

    SOUND-ABSORBING WALL UNITS

    09 9000 PAINTS AND COATINGS

  • VOLUME II of II

    DIVISION 10 - SPECIALTIES

    10 1000 VISUAL DISPLAY BOARDS

    10 1419 DIMENSIONAL LETTER SIGNAGE

    10 4150 ROOM SIGNAGE

    10 4410 FIRE PROTECTION SPECIALTIES

    10 5000 METAL LOCKERS

    10 6170

    10 7300

    UTILITY SHELVING

    ALUMINUM WALKWAY COVERS

    10 8000 TOILET, BATH AND MISCELLANEOUS ACCESSORIES

    DIVISION 11 - EQUIPMENT

    11 2300 COMMERCIAL LAUNDRY EQUIPMENT

    11 3100

    11 4010

    RESIDENTIAL EQUIPMENT

    FOOD SERVICE EQUIPMENT

    11 6500 INDOOR SCOREBOARD

    11 4185 GYMNASIUM EQUIPMENT

    DIVISION 12 - FURNISHINGS

    12 3551 MUSIC INSTRUMENT STORAGE

    12 4093 WINDOW SHADES

    12 6100 FIXED AUDIENCE SEATING

    12 6610 TELESCOPING STANDS

    DIVISION 21 - FIRE SUPPRESSION

    21 2010 FIRE PROTECTION SYSTEM

    DIVISION 22 - PLUMBING

    22 0110

    22 0120

    22 0210

    22 0220

    22 0230

    22 0240

    22 0310

    22 0320

    22 0330

    22 1110

    22 1210

    22 1410

    22 1610

    PLUMBING GENERAL PROVISIONS

    PLUMBING STANDARDS

    PLUMBING COORDINATION

    PLUMBING SUBMITTALS

    PLUMBING IDENTIFICATION

    PLUMBING WORK CLOSEOUT

    PLUMBING PIPE, TUBE AND FITTINGS

    PLUMBING HANGERS AND SUPPORTS

    PLUMBING EXCAVATION

    DOMESTIC WATER PIPING SYSTEM

    SOIL, WASTE, VENT, AND STORM PIPING SYSTEMS

    GAS PIPING SYSTEM

    PLUMBING PIPING SYSTEM INSULATION

  • 22 1710

    22 2210

    22 3110

    22 3210

    PLUMBING VIBRATION AND SEISMIC CONTROL

    WATER HEATERS

    PLUMBING FIXTURES

    ELECTRIC WATER COOLERS & DRINKING FOUNTAINS

    DIVISION 23 - HEATING VENTILATING AND AIR CONDITIONING

    23 0110 GENERAL MECHANICAL PROVISIONS

    23 0120

    23 0210

    23 0220

    23 0230

    23 0240

    23 0310

    23 0320

    23 1210

    23 2110

    23 2210

    23 2310

    23 3110

    23 4320

    23 5310

    23 6110

    23 8310

    23 9110

    23 9210

    MECHANICAL STANDARDS

    MECHANICAL COORDINATION

    MECHANICAL SUBMITTALS

    MECHANICAL IDENTIFICATION

    MECHANICAL WORK CLOSEOUT

    MECHANICAL PIPE, TUBE AND FITTINGS

    MECHANICAL HANGERS AND SUPPORTS

    MECHANICAL PIPING AND EQUIPMENT INSULATION

    DUCTWORK AND ACCESSORIES

    AIR DISTRIBUTION

    FANS

    ELECTRIC HEATERS

    AIR TREATMENT SYSTEMS

    AIR CONDITIONERS

    HEAT PUMPS

    ENERGY MANAGEMENT CONTROL SYSTEM

    MECHANICAL SOUND, VIBRATION, WIND AND SEISMIC CONTROL

    MECHANICAL TESTING, ADJUSTING, BALANCING

    DIVISION 26 - ELECTRICAL

    26 0100

    26 0120

    26 1010

    26 1020

    26 2010

    26 2020

    26 2021

    26 2030

    26 2040

    26 2042

    26 2044

    26 2047

    26 2049

    26 2080

    26 4000

    GENERAL PROVISIONS – ELECTRICAL

    ELECTRICAL SUBMITTALS

    RACEWAY SYSTEMS AND SUPPORTS

    CABLE TRAYS FOR LOW VOLTAGE SYSTEMS

    WIRES AND CABLES, 600V AND BELOW

    WIRING DEVICES

    SAFETY AND DISCONNECT SWITCHES

    LIGHTING FIXTURES

    MOTOR STARTERS

    PANELBOARDS

    SEPARATELY ENCLOSED CIRCUIT BREAKERS

    DRY TYPE TRANSFORMERS, 600V AND BELOW

    SURGE SUPPRESSORS/EHF NOISE FILTERS (SS/EHF)

    ELECTRICAL GROUNDING, 600V AND BELOW

    ELECTRICAL SEISMIC CONTROL

  • DIVISION 27 – COMMUNICATIONS

    27 0100 GENERAL PROVISIONS - COMMUNICATIONS AND ALARM SYSTEMS

    27 0120 COMMUNICATIONS AND ALARM SYSTEMS SUBMITTALS

    27 1010 INTELLIGENT FIRE ALARM SYSTEM

    27 2011 CABLE PLANT LABELING

    27 4010 INTERCOM SYSTEM

    27 4116 INTEGRATED AV COMMUNICATIONS

    27 5010 INTRUSION DETECTION SYSTEM

    27 9010 27 0910 WIRING METHODS FOR COMMUNICATIONS AND ALARM SYSTEMS

    DIVISION 31 – EARTHWORK

    31 1000 DEMOLITION, CLEARING, AND GRUBBING

    31 2300 31 2300 EARTHWORK

    31 2333 TRENCHING

    31 2500 EROSION SEDIMENTATION POLLUTION CONTROL PLAN

    31 2510 COMPREHENSIVE MONITORING PROGRAM

    31 3620 TERMITE CONTROL

    31 4000 SHORING AND UNDERPINNING

    DIVISION 32 – EXTERIOR IMPROVEMENTS

    32 1216 BITUMINOUS CONCRETE PAVEMENT

    32 1300. WALK, ROAD, AND APPURTENANCES

    32 1600 PLAIN CEMENT CONCRETE PAVEMENT

    32 1613 SIDEWALKS

    32 3113 VINYL COATED CHAIN LINK FENCING AND GATES

    32 8400 IRRIGATION SYSTEM

    32 9200 LAWNS AND GRASSES

    32 9300 TREES, PLANTS, AND GROUND COVER

    DIVISION 33 - UTILITIES

    33 1115 FIRE WATER DISTRIBUTION

    33 1116 SITE WATER DISTRIBUTION SYSTEMS

    33 3100 SANITARY SEWAGE SYSTEMS

    33 4000 STORM SEWAGE SYSTEM

    33 4210 CHAMBER STORM DISTRIBUTION SYSTEMS

    END OF TABLE OF CONTENTS

  • 134-18 Woodville Tompkins HS Additions

    VISUAL DISPLAY BOARDS 10 1000

    SECTION 10 1000

    VISUAL DISPLAY BOARDS

    PART 1 - GENERAL

    1.01 RELATED DOCUMENTS

    A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-

    1 Specification sections, apply to work of this Section.

    1.02 DESCRIPTION OF WORK

    A. Extent of chalkboards, markerboards and tackboards indicated on drawings.

    B. Types of chalkboards, markerboards and tackboards specified in Section include following:

    1. Porcelain enamel markerboards.

    2. Vinyl fabric-faced cork tackboards.

    3. Display strips

    1.03 QUALITY ASSURANCE

    A. Manufacturer: Furnish all chalkboards and tackboards by single manufacturer for entire project.

    B. Surface Burning Characteristics:

    1. Use only tackboards labeled and listed by testing and inspection agency acceptable to authorities

    having jurisdiction.

    2. Provide tackboard surfaces identical in composition to those with surface burning characteristics

    indicated below, determined by testing in compliance with ASTM E 84.

    a. Flame Spread: Not more than 25.

    b. Smoke Developed: Not more than 25.

    1.04 SUBMITTALS

    A. Shop Drawings:

    1. Submit shop drawings for each type chalkboard and tackboard.

    2. Include sections of typical trim members and dimensioned elevations.

    3. Show anchors, grounds, reinforcement, accessories, layout and installation details.

    B. Product Data: Submit manufacturer's technical data and installation instructions for each material and

    component part, including data substantiating that materials comply with requirements.

    C. Samples:

    1. Submit full range of color samples for each type chalkboard, tackboard, trim and accessory required.

    2. Provide 12" square samples of sheet materials and 12" lengths of trim members for color verification

    after selections made.

    D. Certification: Submit manufacturer's certification that materials furnished for Project comply with specified

    requirements.

  • 134-18 Woodville Tompkins HS Additions

    VISUAL DISPLAY BOARDS 10 1000

    1.05 SPECIAL PROJECT WARRANTY

    A. Porcelain Enamel Chalkboard/Markerboard Warranty:

    1. Furnish manufacturer's written warranty, agreeing to replace, for lifetime of building, porcelain

    enamel chalkboards which do not retain original writing and erasing qualities, become slick and

    shiny, or exhibit crazing, cracking or flaking; provided manufacturer's instructions with regard to

    handling, installation, protection and maintenance followed.

    2. Replacement limited to material replacement only; labor for removal and reinstallation not included.

    PART 2 - PRODUCTS

    2.01 ACCEPTABLE MANUFACTURERS

    A. Manufacturer: Subject to compliance with requirements, provide products of one of following:

    1. Manufacturers of Porcelain Enamel Markerboards:

    a. American Visual Display b. Claridge Products and

    Equipment, Inc.

    c. Best Rite

    d. Polyvision

    e. Best Rite f. New Line Products

    2. Manufacturers of Tackboards:

    a. American Visual Display. b. Claridge Products and

    Equipment, Inc.

    c. Polyvision d. BestRite

    2.02 MATERIALS

    A. Porcelain Enamel Chalkboards/Markerboards: Balanced, high pressure laminated porcelain enamel

    chalkboards of 3-ply construction consisting of facing sheet, core material and backing.

    1. Facing Sheet:

    a. 24-gage enameling grade steel sheet especially processed for temperatures used in coating porcelain on steel.

    b. Coat exposed face with 3-coat process consisting of primer, ground coat and color cover coat, and concealed face with 2-coat process consisting of primer and ground coat.

    c. Fuse cover and ground coats to steel at manufacturer's standard firing temperatures, but min. 1,200ºF (649ºC).

    2. Optional Proprietary Facing Sheet:

    a. Contractor's option to provide 24-gage "Vitracite", porcelain enamel clad, type 1 stretcher-leveled aluminized steel facing sheet, manufactured by Claridge Products and

    Equipment, Inc. in lieu of facing sheet construction specified above.

    b. Fuse porcelain enamel coating to sheet facing steel at approximately 1,000ºF (538ºC). 3. Cover Coat: Manufacturer's standard gloss finish cover coat for liquid markers, color selected by

    Architect from manufacturer's standards.

    4. Provide staffed markings on boards indicated to receive staff markings in band room.

    5. Core: Manufacturer's standard ⅜” thick particleboard core material, ANSI A208.1, Grade 1-M-1.

    6. Backing Sheet: Manufacturer's standard 0.005" thick aluminum sheet backing.

    7. Laminating Adhesive: Manufacturer's standard moisture-resistant thermoplastic type adhesive.

    B. Vinyl Fabric-Faced Tackboards:

    1. Mildew resistant, washable, vinyl fabric, FS CCC-W-408, Type II, laminated to ¼” thick cork sheet.

    2. Provide only fabric with max. flame spread rating of 25 when tested per ASTM E 84.

  • 134-18 Woodville Tompkins HS Additions

    VISUAL DISPLAY BOARDS 10 1000

    3. Provide color and texture scheduled or selected from manufacturer's standards.

    C. Metal Trim and Accessories:

    1. Fabricate frames and trim of min. 0.062" thick aluminum alloy, size and shape indicated, to suit type

    of installation.

    2. Provide straight, single length units wherever possible; keep joints to min.

    3. Miter corners to neat, hairline closure.

    4. Where size of boards or other conditions exist which require support in addition to normal trim,

    provide structural supports or modify trim as indicated, or as selected by Architect from

    manufacturer's standard structural support accessories to suit condition indicated.

    5. Clear Anodized Finish: Exposed aluminum trim, accessories and fasteners with manufacturer's

    standard satin anodized finish with clear anodic coating complying with AA requirements for Class II

    Architectural Coating (AA-A31).

    6. Chalktray: Furnish manufacturer's standard continuous box type aluminum chalktray with slanted

    front and cast aluminum end closures for each chalkboard.

    7. Map Rail: Furnish map rail at top of each unit, complete with following accessories:

    a. Display Rail: Provide continuous cork display rail approximately 2" wide, as indicated, integral with map rail.

    b. End Stops: Provide one end stop at each end of map rail. c. Map Hooks: Provide 2 map hooks with flexible metal clips for each 4' of map rail or faction

    thereof.

    d. Flagholder: Provide one flagholder for each room. e.

    D. Metal Display Strip:

    1. Fabricate of min. 0.062" thick aluminum alloy, with continuous cork insert, approximately 2" wide,

    having following accessories.

    a. End Stops: Provide one end stop at each end of map rail. b. Map Hooks: Provide 2 map hooks for each 2' of map rail or fraction thereof.

    2. Provide straight, single length units wherever possible; keep joints to min.

    3. Miter corners to neat, hairline closure.

    4. Finish: Clear Anodized Finish:

    a. Exposed aluminum trim, accessories and fasteners with manufacturer's standard satin anodized finish with clear anodic coating complying with AA requirements for Class II

    Architectural Coating (AAA31).

    2.03 FABRICATION

    A. Porcelain Enamel Chalkboards/Markerboards: Laminate facing sheet and backing sheet to core material

    under pressure with manufacturer's recommended flexible, waterproof adhesive.

    B. Assembly:

    1. Provide 4'-0" high units except as otherwise indicated.

    2. Provide factory-assembled chalkboard and tackboard units, except where field-assembled units

    required.

    3. Make joints only where total length exceeds max. manufactured length.

    4. Fabricate with min. number of joints, balanced around center of board, as acceptable to Architect.

    5. Provide manufacturer's standard vertical joint system between abutting sections of chalkboard.

    6. Provide manufacturer's standard mullion trim at joints between chalkboard and tackboard.

  • 134-18 Woodville Tompkins HS Additions

    VISUAL DISPLAY BOARDS 10 1000

    PART 3 - EXECUTION

    3.01 PREPARATION

    A. Field Measurements: Take field measurements prior to preparation of shop drawings and fabrication where possible, to ensure proper fitting of work.

    1. Allow for trimming and fitting wherever taking of field measurements before fabrication might delay work.

    3.02 INSTALLATION

    A. Deliver factory-built units completely assembled in one piece without joints, whenever possible. 1. Where dimensions exceed panel size, provide 2 or more pieces of equal length as acceptable to

    Architect.

    2. When overall dimensions require delivery in separate units, prefit components at factory, disassemble for delivery, and make final joints at site.

    3. Use splines at joints to maintain surface alignment.

    B. Install units in locations and mounting heights indicated and in accordance with manufacturer's instructions. 1. Keep perimeter lines straight, plumb, and level. 2. Provide all grounds, clips, backing materials, adhesives, brackets, anchors, trim and accessories

    necessary for complete installation.

    3. Install using both clips and adhesive

    C. Coordinate job-site assembled units with grounds, trim, and accessories. 1. Join all parts with neat, precision fit.

    3.03 ADJUST AND CLEAN

    A. Verify that accessories required for each unit properly installed and operating units function properly.

    B. Clean units in accordance with manufacturer's instructions.

    END OF SECTION 10 1000

  • 134-18 Woodville Tompkins HS Additions

    DIMENSIONAL LETTER SIGNAGE 10 1419

    SECTION 10 1419

    DIMENSIONAL LETTER SIGNAGE

    PART 1 - GENERAL

    1.1 RELATED DOCUMENTS

    A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

    1.2 SUMMARY

    A. Section Includes: 1. Dimensional Characters. 2. Fabricated Interior Custom Logo (Auditorium) 3. Fabricated Exterior Custom Logo (Gym)

    1.3 DEFINITIONS

    A. Illuminated: Illuminated by lighting source integrally constructed as part of the sign unit.

    1.4 COORDINATION

    A. Furnish templates for placement of electrical service embedded in permanent construction by other installers.

    1.5 ACTION SUBMITTALS

    A. Product Data: For each type of product.

    B. Shop Drawings: For dimensional letter signs. 1. Include fabrication and installation details and attachments to other work. 2. Show sign mounting heights, locations of supplementary supports to be provided by

    others, and accessories.

    3. Show message list, typestyles, graphic elements, and layout for each sign at least 4. Show locations of electrical service connections. 5. Include diagrams for power, signal, and control wiring.

    C. Samples for Initial Selection: For each type of sign assembly, exposed component, and exposed finish.

    1. Include representative Samples of available typestyles and graphic symbols.

    D. Samples for Verification: For each type of sign assembly showing all components and with the required finish(es), in manufacturer's standard size unless otherwise indicated and as follows:

  • 134-18 Woodville Tompkins HS Additions

    DIMENSIONAL LETTER SIGNAGE 10 1419

    1. Dimensional Characters: Half-size Sample max 9 inch of dimensional character.

    E. Sign Schedule: Use same designations specified or indicated on Drawings or in a sign schedule.

    F. Delegated-Design Submittal: 1. Include structural analysis calculations for signs indicated to comply with design loads;

    signed and sealed by the qualified professional engineer responsible for their preparation.

    1.6 INFORMATIONAL SUBMITTALS

    A. Qualification Data: For Installer and manufacturer.

    B. Sample Warranty: For special warranty.

    1.7 CLOSEOUT SUBMITTALS

    A. Maintenance Data: For signs to include in maintenance manuals.

    1.8 QUALITY ASSURANCE

    A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.

    1.9 FIELD CONDITIONS

    A. Field Measurements: Verify locations of electrical service embedded in permanent construction by other installers by field measurements before fabrication, and indicate measurements on

    Shop Drawings.

    1.10 WARRANTY

    A. Special Warranty: Manufacturer agrees to repair or replace components of signs that fail in materials or workmanship within specified warranty period.

    1. Failures include, but are not limited to, the following: a. Deterioration of finishes beyond normal weathering. b. Separation or delamination of sheet materials and components.

    2. Warranty Period: Five years from date of Substantial Completion.

    PART 2 - PRODUCTS

    2.1 DIMENSIONAL LETTER SIGNS, GENERAL

    A. All letters signs logo provided by same manufacture

  • 134-18 Woodville Tompkins HS Additions

    DIMENSIONAL LETTER SIGNAGE 10 1419

    1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

    a. ACE Sign Systems, Inc. b. Allen Markings International. c. APCO Graphics, Inc. d. A. R. K. Ramos Signage Systems. e. ASI Sign Systems, Inc. f. Diskey Sign Company. g. Gemini Incorporated. h. Matthews International Corporation; Bronze Division. i. Metal Arts; Division of L & H Mfg. Co. j. Metallic Arts. k. Seton Identification Products. l. Southwell Company (The).

    2.2 PERFORMANCE REQUIREMENTS

    A. Delegated Design: Engage a qualified professional engineer, as defined in Section 014000 "Quality Requirements," to design sign structure and anchorage of rooftop dimensional

    character sign type(s) to withstand design loads.

    B. Thermal Movements: For exterior fabricated channel dimensional characters, allow for thermal movements from ambient and surface temperature changes.

    1. Temperature Change: 120 deg F , ambient; 180 deg F , material surfaces.

    C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.

    2.3 DIMENSIONAL CHARACTERS

    A. Exterior letters and custom logo mounted to building. Characters shall have uniform faces, sharp corners, and precisely formed lines and profiles, and as follows:

    1. Location on exterior masonry wall outside gym entrance: “WOLVERINES” 2. Character Material: Cut Aluminum 3. Character Height: 14” 4. Font: Architectural, Impact (MS Word) 5. Profile Flat 6. Thickness: Manufacturer’s standard 7. Custom Logo: Owner’s supplied graphic 8. Logo Material: Same as dimensional characters 9. Logo size: Approximately 6’-0” x 6’-0” 10. Finishes: Anodized 11. Mounting: Projecting studs. Standoff wall approx 2”

    B. Cast Characters Interior letters. Characters shall have uniform faces, sharp corners, and precisely formed lines and profiles, and as follows:

    http://www.specagent.com/LookUp/?uid=123456827785&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827786&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827787&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827788&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827789&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827790&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827791&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827792&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827793&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827794&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827795&mf=04&src=wdhttp://www.specagent.com/LookUp/?uid=123456827796&mf=04&src=wd

  • 134-18 Woodville Tompkins HS Additions

    DIMENSIONAL LETTER SIGNAGE 10 1419

    1. Location above display cases in Gym Lobby 300: “W O L V E R I N E N A T I O N” 2. Character Material: Cut Aluminum 3. Character Height: 10” 4. Font: Architectural, Impact (MS Word) 5. Profile Flat 6. Thickness: Manufacturer’s standard 7. Finishes: Anodized 8. Mounting: Projecting studs. Standoff wall approx ½”

    C. Cast interior lettering and custom logo. Characters shall have uniform faces, sharp corners, and precisely formed lines and profiles, and as follows:

    1. Location in corridor 349 adjacent to door 349.1 2. Material: Cut Aluminum 3. Font: Architectural, Calibri (MS Word) 4. Profile Flat 5. Thickness: Manufacturer’s standard 6. Custom Logo: Owner’s supplied graphic cut from aluminum panel. 7. Logo size: Approximately 18”x54” 8. Finishes: Anodized 9. Mounting: Projecting studs. Standoff wall approx ½”

    2.4 DIMENSIONAL CHARACTER MATERIALS

    A. Aluminum Castings: ASTM B 26/B 26M, alloy and temper recommended by sign manufacturer for casting process used and for type of use and finish indicated.

    B. Aluminum Sheet and Plate: ASTM B 209 alloy and temper recommended by aluminum producer and finisher for type of use and finish indicated.

    C. Aluminum Extrusions: ASTM B 221 alloy and temper recommended by aluminum producer and finisher for type of use and finish indicated.

    D. Paints and Coatings for Sheet Materials: Inks, dyes, and paints that are recommended by manufacturer for optimum adherence to surface and are UV and water resistant for colors and

    exposure indicated.

    2.5 ACCESSORIES

    A. Fasteners and Anchors: Manufacturer's standard as required for secure anchorage of signage, noncorrosive and compatible with each material joined, and complying with the following:

    1. Use concealed fasteners and anchors unless indicated to be exposed. 2. For exterior exposure, furnish stainless-steel devices unless otherwise indicated.

    3. Sign Mounting Fasteners:

    a. Concealed Studs: Concealed (blind), threaded studs welded or brazed to back of sign material, screwed into back of sign assembly, or screwed into tapped lugs cast

    integrally into back of cast sign material, unless otherwise indicated.

  • 134-18 Woodville Tompkins HS Additions

    DIMENSIONAL LETTER SIGNAGE 10 1419

    b. Projecting Studs: Threaded studs with sleeve spacer, welded or brazed to back of sign material, screwed into back of sign assembly, or screwed into tapped lugs cast

    integrally into back of cast sign material, unless otherwise indicated.

    2.6 FABRICATION

    A. General: Provide manufacturer's standard sign assemblies according to requirements indicated. 1. Preassemble signs and assemblies in the shop to greatest extent possible. Disassemble

    signs and assemblies only as necessary for shipping and handling limitations. Clearly

    mark units for reassembly and installation; apply markings in locations concealed from

    view after final assembly.

    2. Mill joints to a tight, hairline fit. Form assemblies and joints exposed to weather to resist water penetration and retention.

    3. Comply with AWS for recommended practices in welding and brazing. Provide welds and brazes behind finished surfaces without distorting or discoloring exposed side. Clean

    exposed welded and brazed connections of flux, and dress exposed and contact surfaces.

    4. Conceal connections if possible; otherwise, locate connections where they are inconspicuous.

    5. Internally brace signs for stability and for securing fasteners. 6. Provide rebates, lugs, and brackets necessary to assemble components and to attach to

    existing work. Drill and tap for required fasteners. Use concealed fasteners where

    possible; use exposed fasteners that match sign finish.

    7. Castings: Fabricate castings free of warp, cracks, blowholes, pits, scale, sand holes, and other defects that impair appearance or strength. Grind, wire brush, sandblast, and buff

    castings to remove seams, gate marks, casting flash, and other casting marks before

    finishing.

    2.7 GENERAL FINISH REQUIREMENTS

    A. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

    B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of

    approved Samples and are assembled or installed to minimize contrast.

    C. Directional Finishes: Run grain with long dimension of each piece and perpendicular to long dimension of finished trim or border surface unless otherwise indicated.

    D. Organic, Anodic, and Chemically Produced Finishes: Apply to formed metal after fabrication but before applying contrasting polished finishes on raised features unless otherwise indicated.

    2.8 ALUMINUM FINISHES

    A. Color Anodic Finish: AAMA 611, AA-M12C22A42/A44, Class I, 0.018 mm or thicker.

    1. Color: Clear

  • 134-18 Woodville Tompkins HS Additions

    DIMENSIONAL LETTER SIGNAGE 10 1419

    PART 3 - EXECUTION

    3.1 EXAMINATION

    A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of signage

    work.

    B. Verify that sign-support surfaces are within tolerances to accommodate signs without gaps or irregularities between backs of signs and support surfaces unless otherwise indicated.

    C. Verify that electrical service is correctly sized and located to accommodate signs.

    D. Proceed with installation only after unsatisfactory conditions have been corrected.

    3.2 INSTALLATION

    A. General: Install signs using mounting methods indicated and according to manufacturer's written instructions.

    1. Install signs level, plumb, true to line, and at locations and heights indicated, with sign surfaces free of distortion and other defects in appearance.

    2. Before installation, verify that sign surfaces are clean and free of materials or debris that would impair installation.

    3. Corrosion Protection: Coat concealed surfaces of exterior aluminum in contact with grout, concrete, masonry, wood, or dissimilar metals, with a heavy coat of bituminous

    paint.

    B. Mounting Methods: 1. Projecting Studs: Using a template, drill holes in substrate aligning with studs on back of

    sign. Remove loose debris from hole and substrate surface.

    a. Masonry Substrates: Fill holes with adhesive. Leave recess space in hole for displaced adhesive. Place spacers on studs, place sign in position, and push until

    spacers are pinched between sign and substrate, embedding the stud ends in holes.

    Temporarily support sign in position until adhesive fully sets.

    b. Thin or Hollow Surfaces: Place spacers on studs, place sign in position with spacers pinched between sign and substrate, and install washers and nuts on stud

    ends projecting through opposite side of surface, and tighten.

    2. Back Bar and Brackets: Remove loose debris from substrate surface and install backbar or bracket supports in position so that signage is correctly located and aligned.

    3.3 ADJUSTING AND CLEANING

    A. Remove and replace damaged or deformed characters and signs that do not comply with specified requirements. Replace characters with damaged or deteriorated finishes or

    components that cannot be successfully repaired by finish touchup or similar minor repair

    procedures.

    B. Remove temporary protective coverings and strippable films as signs are installed.

  • 134-18 Woodville Tompkins HS Additions

    DIMENSIONAL LETTER SIGNAGE 10 1419

    C. On completion of installation, clean exposed surfaces of signs according to manufacturer's written instructions, and touch up minor nicks and abrasions in finish. Maintain signs in a clean

    condition during construction and protect from damage until acceptance by Owner.

    END OF SECTION 10 1419

  • 134-18 Woodville Tompkins HS Additions

    SIGNAGE AND PLAQUES 10 4150

    SECTION 10 4150

    SIGNAGE

    PART 1 - GENERAL

    1.01 RELATED DOCUMENTS

    A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-

    1 Specification sections, apply to work of this Section.

    1.02 DESCRIPTION OF WORK

    A. Extent of Room signs .

    1.03 QUALITY ASSURANCE

    A. Uniformity of Manufacturer: For each sign form and graphic image process indicated, furnish products of

    single manufacturer.

    1.04 SUBMITTALS

    A. Shop Drawings:

    1. Submit shop drawings for fabrication and erection of specialty signs.

    2. Include plans, elevations, and large scale details of sign wording and lettering layout.

    3. Show anchorages and accessory items.

    4. Submit min. four (4) copies of complete list itemizing all rooms showing room name and number,

    including disabled accessibility signs.

    (a) Indicate door number where sign located or other identifying designation.

    (b) Indicated number of lines and size of sign required for text required.

    (c) Utilize room names and numbers shown on drawings for initial submittal.

    (d) After review of initial submittal by Architect and Owner, submit final list for review and

    approval.

    B. Product Data: Submit manufacturer's technical data and installation instructions for each type of sign

    required.

    C. Samples:

    1. Submit samples of each sign form and material showing finishes, colors, surface textures and

    qualities of manufacturer and design of each sign component including graphics.

    2. Submit full-size sample units.

    3. Acceptable units may be installed as part of Work.

    1.05 REFERENCE STANDARDS

    A. Disability Compliance: Meet requirements of Georgia Code Chapter 120-3-20 "Accessibility Code for

    Buildings and Facilities”.

  • 134-18 Woodville Tompkins HS Additions

    SIGNAGE AND PLAQUES 10 4150

    PART 2 - PRODUCTS

    2.01 ACCEPTABLE MANUFACTURERS

    A. Manufacturer: Subject to compliance with requirements, provide products of one of following:

    1. Manufacturers of Panel Signs:

    (a) Allenite, A Division of Allen

    Marking Products, Inc.

    (b) Andco Industries Corp.

    (c) American Graphics, Inc.

    (d) Amerson Engraving Co.

    (e) Architectural Graphics, Inc.

    (f) Architectural Sign Systems,

    Inc.

    (g) ASI Sign Systems, Inc.

    (h) Best Manufacturing Co.

    (i) Bayuk Graphic

    (j) Mohawk Sign Systems.

    (k) Multi-Graphics, Inc.

    (l) N-Tect, Inc.

    (m) Sign Productions, Inc.

    (n) Spanjer Brothers, Inc.

    (o) The Supersine Company.

    (p) Vomar Products, Inc.

    2.02 MATERIALS

    A. Plastic Laminate: High pressure engraving stock with face and core plies in contrasting colors, in finishes and

    color combinations indicated or, if not indicated, selected by Architect from manufacturer's standards.

    B. Fasteners: Unless otherwise indicated, concealed fasteners fabricated from metals non-corrosive to either

    sign material or mounting surface.

    C. Anchors and Inserts:

    1. Non-ferrous metal or hot-dipped galvanized anchors and inserts for exterior installations and

    elsewhere as required for corrosion resistance.

    2. Toothed steel or lead expansion bolt devices for drilled-in-place anchors.

    3. Inserts, as required, set into concrete or masonry work.

    2.03 PANEL SIGNS, ROOM SIGNS

    A. Fabricate panel signs to comply with requirements indicated for materials, thicknesses, finishes, colors,

    designs, shapes, sizes and details of construction.

    B. Produce smooth, even, level sign panel surfaces, constructed to remain flat under installed condition within

    tolerance of +1/16" measured diagonally.

    C. Unframed Panel Signs: Fabricate unframed panel signs with edges mechanically and smoothly finished to

    conform with following requirements:

    1. Edge Condition: Square cut.

    2. Edge Color for Plastic Laminate: Same as background.

    3. Corner Condition: Rounded to radius indicated.

    D. Graphic Image Process:

    1. Graphic Content and Style: Provide sign copy to comply with requirements indicated for sizes,

    styles, spacing, content, positions, materials, finishes and colors of letters, numbers, symbols and

    other graphic devices.

    2. Pictograms:

    (a) All pictograms based on international symbols and those developed by U. S. Department of

    Transportation.

    (b) Accompany by verbal and braille description below pictogram.

    (c) Required Pictograms:

  • 134-18 Woodville Tompkins HS Additions

    SIGNAGE AND PLAQUES 10 4150

    (1) Accessibility Symbol.

    (d) Pictogram plaques same as interior door plaques.

    (e) Refer to drawing at end of this Section.

    3. Characters: Meet ADA requirements for proportion of height and width and height and stroke width.

    (a) Characters: "Helvetica" Medium C, all same height, minimum 1".

    (b) Braille: Provide below characters.

    4. Sign Size: Min. 6" x 6" but as required to maintain min. 1" between lettering and edge.

    5. Sand-cut or Machine-cut Engraved Copy - Raised Characters:

    (a) Sand-cut or machine-cut background to produce raised letters, numbers, symbols and other

    graphic devices on sign panel on face indicated to provide precisely formed copy, with

    background incised to uniform depth.

    (b) If machine cut, use high speed cutters mechanically linked to master templates in

    pantographic system or equivalent process capable of producing characters of style indicated

    with sharply formed edges.

    (c) Plastic Laminate: Cut through exposed face ply of plastic laminate sheet to expose

    contrasting core ply.

    (d) Produce copy to provide min. indentation depth of 1/32" and min, stroke width of ¼".

    6. Name Slot:

    (a) Window: Clear plastic over slot for insertion of plastic strip containing copy by Owner.

    (1) Required only at Corridor or Passage door locations of staff occupied areas.

    (2) Size: 1" clear height, ⅞" viewing height x width of sign.

    (3) As indicated.

    (4) Provide back-coated .020" thick rigid vinyl insert 1/6" less than height of slot x full

    width of slot.

    (5) Locate on sign as directed by Architect.

    E. Copy Content:

    1. Refer to Part 3 of this Section for locations.

    2. Room Identification Signs:

    (a) Room name, characters and braille

    (b) Room number, characters and braille

    3. Disabled Accessible Toilet Signs:

    (a) Accessibility symbol

    (b) Text "MEN", "WOMEN", "BOYS", "GIRLS" or "TOILET" as applicable, characters and

    braille

    (c) See drawing at end of this Section.

    2.04 FINISHES

    A. Colors and Surface Textures: For exposed sign material that requires selection of materials with integral or

    applied colors, surface textures or other characteristics related to appearance, provide color matches indicated,

    or if not indicated, as selected by Architect from manufacturer's standards.

    2.05 Field-Applied, Vinyl-Character Sign Prespaced characters die cut from 3- to 3.5-mil thick, weather-resistant

    vinyl film with release liner on the back and carrier film on the front for on-site alignment and application.

    PART 3 - EXECUTION

  • 134-18 Woodville Tompkins HS Additions

    SIGNAGE AND PLAQUES 10 4150

    3.01 LOCATIONS

    A. Room Identification:

    1. Provide one sign for every interior door location except disabled accessible toilets.

    2. Install signs on wall at latch side of doors outside of space identified, centered 60" above finished

    floor.

    B. Disabled Accessible Toilets:

    1. Provide one sign for every battery or individual toilet room containing provisions for disabled.

    2. Install signs on wall at push/pull or latch side of door outside of toilet, centered 60" above finished

    floor.

    C. Exterior mechinacel rooms provide die cut vinyl sign with 3” tall letters White ( Apply to door)

    3.02 INSTALLATION

    A. General: Use mounting methods of type described and in compliance with manufacturer's instructions, unless

    otherwise indicated.

    B. Install sign units level, plumb and at height indicated, with sign surfaces free from distortion or other defects

    of appearance.

    C. Wall-Mounted Panel Signs:

    1. Attach panel signs to wall surfaces using methods indicated below:

    (a) Mechanical Fasteners:

    (1) Where above methods not practical, provide screws and plastic shields or similar

    devices, size and type recommended by manufacturer.

    (2) Color of exposed portion of fastener match sign surface it penetrates.

    (b) If exposed fasteners used, color of exposed portion of fastener to match plaque and provide

    neat and uniform appearance.

    3.03 CLEANING AND PROTECTION

    A. At completion of installation, clean soiled sign surfaces in accordance with manufacturer's instructions.

    1. Protect units from damage until acceptance by Owner.

    END OF SECTION 10 4150

  • 134-18 Woodville Tompkins HS Additions

    FIRE PROTECTION SPECIALTIES 10 4410

    SECTION 10 4410

    FIRE PROTECTION SPECIALTIES

    PART 1 - GENERAL

    1.1 RELATED DOCUMENTS

    A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

    1.2 SUMMARY

    A. Section Includes:

    1. Fire-protection cabinets for the following:

    a. Portable fire extinguisher. b. Portable fire extinguisher Cabinets c. Portable fire extinguisher, Brackets

    1.3 ACTION SUBMITTALS

    A. Product Data: For each type of product.

    1. Show door hardware, cabinet type, trim style, and panel style. Include roughing-in dimensions and details showing recessed-, semirecessed-, or surface-mounting method

    and relationships of box and trim to surrounding construction.

    2. Show location of knockouts for hose valves.

    B. Shop Drawings: For fire-protection cabinets.

    1. Include plans, elevations, sections, details, and attachments to other work.

    C. Samples: For each type of exposed finish required.

    D. Samples for Initial Selection: For each type of exposed finish required.

    E. Samples for Verification: For each type of exposed finish required, prepared on samples 6 by 6 inches (150 by 150 mm) square.

    F. Product Schedule: For fire-protection cabinets. Indicate whether recessed, semirecessed, or surface mounted. Coordinate final fire-protection cabinet schedule with fire-extinguisher

    schedule to ensure proper fit and function.[ Use same designations indicated on Drawings.]

  • 134-18 Woodville Tompkins HS Additions

    FIRE PROTECTION SPECIALTIES 10 4410

    1.4 CLOSEOUT SUBMITTALS

    A. Maintenance Data: For fire-protection cabinets to include in maintenance manuals.

    1.5 COORDINATION

    A. Coordinate sizes and locations of fire-protection cabinets with wall depths.

    B. Drawing Type Designations

    1. Type "A": Specified extinguisher contained in specified cabinet. 2. Type "B": Specified extinguisher supported by specified bracket.

    1.6 WARRANTY

    A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace fire extinguishers that fail in materials or workmanship within specified warranty

    period.

    1. Failures include, but are not limited to, the following: a. Failure of hydrostatic test according to NFPA 10 when testing interval required by

    NFPA 10 is within the warranty period.

    b. Faulty operation of valves or release levers.

    2. Warranty Period: Six years from date of Substantial Completion.

    B.

    PART 2 - PRODUCTS

    2.1 MANUFACTURERS

    A. Source Limitations: Obtain fire-protection cabinets, accessories, and fire extinguishers from single source from single manufacturer.

    2.2 PORTABLE, HAND-CARRIED FIRE EXTINGUISHERS

    A. NFPA Compliance: Fabricate and label fire extinguishers to comply with NFPA 10, "Portable Fire Extinguishers."

    B. Fire Extinguishers: Type, size, and capacity for each fire-protection cabinet and mounting bracket indicated.

    1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

    a. Babcock-Davis. b. Fire End & Croker Corporation. c. Kidde Residential and Commercial Division.

    http://www.specagent.com/Lookup?ulid=703http://www.specagent.com/Lookup?uid=123457127333http://www.specagent.com/Lookup?uid=123457127321http://www.specagent.com/Lookup?uid=123457127323

  • 134-18 Woodville Tompkins HS Additions

    FIRE PROTECTION SPECIALTIES 10 4410

    d. Larsens Manufacturing Company. e. Nystrom, Inc. f. Pyro-Chem; Tyco Fire Suppression & Building Products. g. Strike First Corporation of America (The).

    2. Source Limitations: Obtain fire extinguishers, fire-protection cabinets, and accessories, from single source from single manufacturer.

    3. Valves: Manufacturer's standard. 4. Handles and Levers: Manufacturer's standard. 5. Instruction Labels: Include pictorial marking system complying with NFPA 10,

    Appendix B, and bar coding for documenting fire-extinguisher location, inspections,

    maintenance, and recharging.

    C. Multipurpose Dry-Chemical Type in Aluminum Container: UL-rated 4-A:60-B:C, 10-lb nominal capacity, with monoammonium phosphate-based dry chemical in enameled-aluminum

    container.

    D. Purple-K Dry-Chemical Type in Aluminum Container: UL-rated 120-B:C, 20-lb nominal capacity, with potassium bicarbonate-based dry chemical in enameled-aluminum container.

    E. Mounting Brackets: Manufacturer's standard galvanized steel, designed to secure fire extinguisher to wall or structure, of sizes required for types and capacities of fire extinguishers

    indicated, with plated or black baked-enamel finish.

    2.3 FIRE-PROTECTION CABINET

    A. Fire-Rated Fire-Protection Cabinets: Listed and labeled to comply with requirements in ASTM E814 for fire-resistance rating of walls where they are installed.

    B. Cabinet Type: Suitable for fire extinguisher.

    1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

    a. Fire-End & Croker Corporation. b. JL Industries, Inc.; a division of the Activar Construction Products Group. c. Larsens Manufacturing Company. d. Modern Metal Products, Division of Technico Inc. e. Nystrom, Inc. f. Potter Roemer LLC.

    C. Cabinet Construction: Nonrated and fire rated.

    1. Fire-Rated Cabinets: Construct fire-rated cabinets with double walls fabricated from 0.043-inch- thick cold-rolled steel sheet lined with minimum 5/8-inch- thick fire-barrier

    material. Provide factory-drilled mounting holes.

    D. Cabinet Material: Steel sheet. 1. Shelf: Same metal and finish as cabinet.

    E. Recessed Cabinet:

    http://www.specagent.com/Lookup?uid=123457127324http://www.specagent.com/Lookup?uid=123457127331http://www.specagent.com/Lookup?uid=123457127329http://www.specagent.com/Lookup?uid=123457127332http://www.specagent.com/Lookup?ulid=699http://www.specagent.com/Lookup?uid=123457098410http://www.specagent.com/Lookup?uid=123457098411http://www.specagent.com/Lookup?uid=123457098412http://www.specagent.com/Lookup?uid=123457098409http://www.specagent.com/Lookup?uid=123457098415http://www.specagent.com/Lookup?uid=123457098408

  • 134-18 Woodville Tompkins HS Additions

    FIRE PROTECTION SPECIALTIES 10 4410

    1. Exposed Flat Trim: One-piece combination trim and perimeter door frame overlapping surrounding wall surface, with exposed trim face and wall return at outer edge

    (backbend).

    F. Cabinet Trim Material: Aluminum sheet.

    G. Door Material: Aluminum sheet.

    H. Door Style: Fully glazed panel with frame.

    I. Door Glazing: Tempered float glass (clear).

    J. Door Hardware: Manufacturer's standard door-operating hardware of proper type for cabinet type, trim style, and door material and style indicated.

    1. Provide projecting door pull and friction latch. 2. Provide manufacturer's standard hinge, permitting door to open 180 degrees.

    K. Accessories:

    1. Mounting Bracket: Manufacturer's standard steel, designed to secure fire extinguisher to fire-protection cabinet, of sizes required for types and capacities of fire extinguishers

    indicated, with plated or baked-enamel finish.

    2. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as directed by Architect.

    a. Identify fire extinguisher in fire-protection cabinet with the words "FIRE EXTINGUISHER."

    1) Location: Applied to cabinet door. 2) Application Process: Silk-screened. 3) Lettering Color: Black. 4) Orientation: Vertical.

    L. Materials: 1. Aluminum: ASTM B221 for extruded shapes and aluminum sheet, with strength and

    durability characteristics of not less than Alloy 6063-T5 for aluminum sheet.

    a. Finish: Clear anodic. 2. Tempered Float Glass: ASTM C1048, Kind FT, Condition A, Type I, Quality q3, 3 mm

    thick, Class 1 (clear).

    PART 3 - EXECUTION

    3.1 EXAMINATION

    A. Examine walls and partitions for suitable framing depth and blocking where recessed cabinets will be installed.

    B. Proceed with installation only after unsatisfactory conditions have been corrected.

  • 134-18 Woodville Tompkins HS Additions

    FIRE PROTECTION SPECIALTIES 10 4410

    3.2 PREPARATION

    A. Prepare recesses for recessed fire-protection cabinets as required by type and size of cabinet and trim style.

    3.3 INSTALLATION

    A. General: Install fire-protection cabinets in locations and at mounting heights indicated or, if not indicated, at height indicated below:

    1. Fire-Protection Cabinets: 42 inches above finished floor to top of fire extinguisher.

    B. Fire-Protection Cabinets: Fasten cabinets to structure, square and plumb. 1. Unless otherwise indicated, provide recessed fire-protection cabinets. If wall thickness is

    inadequate for recessed cabinets, provide semirecessed fire-protection cabinets.

    2. Provide inside latch and lock for break-glass panels. 3. Fasten mounting brackets to inside surface of fire-protection cabinets, square and plumb.

    C. General: Install fire extinguishers and mounting brackets in locations indicated and in compliance with requirements of authorities having jurisdiction.

    1. Mounting Brackets: Top of fire extinguisher to be at 42 inches above finished floor.

    D. Mounting Brackets: Fasten mounting brackets to surfaces, square and plumb, at locations indicated.

    1.

    3.4 ADJUSTING AND CLEANING

    A. Remove temporary protective coverings and strippable films, if any, as fire-protection cabinets are installed unless otherwise indicated in manufacturer's written installation instructions.

    B. Adjust fire-protection cabinet doors to operate easily without binding. Verify that integral locking devices operate properly.

    C. On completion of fire-protection cabinet installation, clean interior and exterior surfaces as recommended by manufacturer.

    D. Touch up marred finishes, or replace fire-protection cabinets that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by fire-

    protection cabinet and mounting bracket manufacturers.

    E. Replace fire-protection cabinets that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures.

    END OF SECTION 10 4410

  • 134-18 Woodville Tompkins HS Additions

    METAL LOCKERS 10 5000

    SECTION 10 5000

    METAL LOCKERS

    PART 1 - GENERAL

    1.1 RELATED DOCUMENTS

    A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

    1.2 SUMMARY

    A. Section Includes: 1. Heavy-duty metal lockers. 2. Athletic metal lockers.

    1.3 ACTION SUBMITTALS

    A. Product Data: For each type of product indicated. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for each type of

    metal locker.

    B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

    1. Show locker trim and accessories. 2. Include locker identification system and numbering sequence.

    C. Samples for Initial Selection: For units with factory-applied color finishes.

    1.4 INFORMATIONAL SUBMITTALS

    A. Qualification Data: For qualified Installer.

    B. Warranty: Sample of special warranty.

    1.5 CLOSEOUT SUBMITTALS

    A. Maintenance Data: For adjusting, repairing, and replacing locker doors and latching mechanisms to include in maintenance manuals.

  • 134-18 Woodville Tompkins HS Additions

    METAL LOCKERS 10 5000

    1.6 QUALITY ASSURANCE

    A. Installer Qualifications: Manufacturer's authorized representative who is trained and approved for installation of units required for this Project.

    B. Source Limitations: Obtain metal lockers and accessories from single source from single manufacturer.

    C. Preinstallation Conference: Conduct conference at Project site.

    1.7 DELIVERY, STORAGE, AND HANDLING

    A. Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for their installation.

    1.8 PROJECT CONDITIONS

    A. Field Measurements: Verify actual dimensions of recessed openings by field measurements before fabrication.

    1.9 COORDINATION

    A. Coordinate sizes and locations of concrete bases for metal lockers.

    B. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of work specified in other Sections to ensure that metal lockers can be supported and

    installed as indicated.

    1.10 WARRANTY

    A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish,

    within specified warranty period.

    1. Failures include, but are not limited to, the following: a. Structural failures. b. Faulty operation of latches and other door hardware.

    2. Damage from deliberate destruction and vandalism is excluded. 3. Warranty Period for Knocked-Down Metal Lockers: Two years from date of Substantial

    Completion.

    4. Warranty Period for All-Welded Metal Lockers: 10 years from date of Substantial Completion.

  • 134-18 Woodville Tompkins HS Additions

    METAL LOCKERS 10 5000

    PART 2 - PRODUCTS

    2.1 MATERIALS

    A. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for exposed applications.

    B. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; with A60 zinc-iron, alloy (galvannealed) coating designation.

    C. Extruded Aluminum: ASTM B 221 , alloy and temper recommended by aluminum producer and manufacturer for type of use and finish indicated.

    D. Steel Tube: ASTM A 500, cold rolled.

    E. Fasteners: Zinc- or nickel-plated steel, slotless-type, exposed bolt heads; with self-locking nuts or lock washers for nuts on moving parts.

    F. Anchors: Material, type, and size required for secure anchorage to each substrate. 1. Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors.

    2.2 ATHLETIC METAL LOCKERS

    1. Products: Fully welded, Athletic Metal Lockers :Subject to compliance with requirements, provide one of the following:

    2. Art Metal Products; 3. DeBourgh Mfg. Co.; 4. List Industries Inc.; Marquis Protector. 5. Lyon Workspace Products, LLC; 6. Penco Products, Inc.; 7. Republic

    B. Locker Arrangement: As indicated on Drawings 1. Location Boys and Girls PE lockers; double-tier arrangement. Each 12 x 12 x 36 High

    total 72” high.

    2. Boys and girls Varsity Lockers; Each double-tier 24 x 24 x 36 high total 72” high.

    C. Material: Cold-rolled steel sheet.

    D. Body: Assembled by welding components together. Fabricate from unperforated steel sheet with thicknesses as follows:

    1. Tops and Bottoms: 14-gauge nominal thickness, with single bend at edges. 2. Backs: 14 gauge-inch nominal thickness. 3. Shelves: 14 gauge-inch nominal thickness, with double bend at front and single bend at

    sides and back.

    E. Unperforated Sides: Fabricated from 0.048-inch nominal-thickness steel sheet.

    F. Perforated Sides: Fabricated from 0.060-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations.

    http://www.specagent.com/LookUp/?ulid=711&mf=95&src=wdhttp://www.specagent.com/LookUp/?ulid=712&mf=95&src=wdhttp://www.specagent.com/LookUp/?uid=123456793854&mf=95&src=wdhttp://www.specagent.com/LookUp/?uid=123456793855&mf=95&src=wdhttp://www.specagent.com/LookUp/?uid=123456793856&mf=95&src=wdhttp://www.specagent.com/LookUp/?uid=123456793857&mf=95&src=wdhttp://www.specagent.com/LookUp/?uid=123456793858&mf=95&src=wd

  • 134-18 Woodville Tompkins HS Additions

    METAL LOCKERS 10 5000

    G. Frames: Channel formed; fabricated from 0.060-inch nominal-thickness steel sheet or 0.097-inch nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom

    main frames factory welded into vertical main frames. Form continuous, integral door strike

    full height on vertical main frames.

    1. Cross Frames for Double-Tier and Triple-Tier Lockers: Channel formed and fabricated from same material as main frames; welded to vertical main frames.

    H. Reinforced Bottoms: Structural channels, formed from 0.075-inch nominal-thickness steel sheet; welded to front and rear of side-panel frames.

    I. Perforated Doors: One piece; fabricated from 0.075-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at

    vertical edges and with right-angle single bend at horizontal edges and latch point (bottom) and

    right-angle single bend at remaining edges for box lockers.

    1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 15 inches wide; welded to inner face of doors.

    J. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed;

    fabricated to swing 180 degrees

    1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches high. Provide no fewer than three hinges for each door more than 42 inches high.

    2. Continuous Hinges: Manufacturer's standard, steel; side or top mounted as required by locker configuration.

    3. Hinges: Manufacturer's standard, steel continuous or knuckle type.

    K. Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond face of door; pry and vandal resistant.

    1. Multipoint Latching: Finger-lift latch control designed for use with built-in combination locks, built-in cylinder locks, or padlocks; positive automatic latching and prelocking.

    a. Latch Hooks: Equip doors 48 inches and higher with three latch hooks and doors less than 48 inches high with two latch hooks; fabricated from 0.120-inch nominal-

    thickness steel sheet; welded to full-height door strikes; with resilient silencer on

    each latch hook.

    b. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism and moving components isolated to prevent metal-to-metal contact, and incorporating a

    prelocking device that allows locker door to be locked while door is open and then

    closed without unlocking or damaging lock or latching mechanism.

    L. Door Handle and Latch for Box Lockers: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

    M. Combination Padlocks: Provided by Owner.

    N. Equipment: Equip each metal locker with identification plate and the following unless otherwise indicated:

    1. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks.

    2. Double-Tier Units: One double-prong ceiling hook and two single-prong wall hooks.

  • 134-18 Woodville Tompkins HS Additions

    METAL LOCKERS 10 5000

    O. Accessories: 1. Continuous Sloping Tops: Fabricated from 0.048-inch nominal-thickness steel sheet,

    with a pitch of approximately 20 degrees.

    a. Closures: Vertical-end type.

    2. Recess Trim: Fabricated from 0.048-inch nominal-thickness steel sheet. 3. Filler Panels: Fabricated from 0.048-inch nominal-thickness steel sheet. 4. Boxed End Panels: Fabricated from 0.060-inch nominal-thickness steel sheet.

    P. Finish: Baked enamel or powder coat. 1. Color(s): As selected by Architect from manufacturer's full range.

    2.3 FABRICATION

    A. Fabricate metal lockers square, rigid, and without warp and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs.

    1. Form body panels, doors, shelves, and accessories from one-piece steel sheet unless otherwise indicated.

    2. Provide fasteners, filler plates, supports, clips, and closures as required for complete installation.

    B. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments. Factory weld frame

    members of each metal locker together to form a rigid, one-piece assembly.

    C. All-Welded Construction: Factory preassemble metal lockers by welding all joints, seams, and connections; with no bolts, nuts, screws, or rivets used in assembly of main locker groups.

    Factory weld main locker groups into one-piece structures. Grind exposed welds flush.

    D. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

    E. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 3/8 inch high.

    F. Continuous Sloping Tops: Fabricated in lengths as long as practical, without visible fasteners at splice locations; finished to match lockers.

    1. Sloping-top corner fillers, mitered.

    G. Recess Trim: Fabricated with minimum 2-1/2-inch face width and in lengths as long as practical; finished to match lockers.

    H. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel.

    I. Boxed End Panels: Fabricated with 1-inch- wide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers.

    1. Provide one-piece panels for double-row (back-to-back) locker ends.

    J. Finished End Panels: Designed for concealing unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers.

  • 134-18 Woodville Tompkins HS Additions

    METAL LOCKERS 10 5000

    1. Provide one-piece panels for double-row (back-to-back) locker ends.

    K. Center Dividers: Full-depth, vertical partitions between bottom and shelf; finished to match lockers.

    2.4 STEEL SHEET FINISHES

    A. Factory finish steel surfaces and accessories except stainless-steel and chrome-plated surfaces.

    B. Baked-Enamel Finish: Immediately after cleaning, pretreating, and phosphatizing, apply manufacturer's standard thermosetting baked-enamel finish. Comply with paint manufacturer's

    written instructions for application, baking, and minimum dry film thickness.

    C. Powder-Coat Finish: Immediately after cleaning and pretreating, electrostatically apply manufacturer's standard, baked-polymer, thermosetting powder finish. Comply with resin

    manufacturer's written instructions for application, baking, and minimum dry film thickness.

    PART 3 - EXECUTION

    3.1 EXAMINATION

    A. Examine walls, floors, and support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.

    B. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work.

    C. Proceed with installation only after unsatisfactory conditions have been corrected.

    3.2 INSTALLATION

    A. General: Install level, plumb, and true; shim as required, using concealed shims. 1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more

    than 36 inches o.c. Using concealed fasteners, install anchors through backup reinforcing

    plates, channels, or blocking as required to prevent metal distortion.

    2. Anchor single rows of metal lockers to walls near top and bottom of lockers. 3. Anchor back-to-back metal lockers to floor.

    B. Knocked-Down Metal Lockers: Assemble with standard fasteners, with no exposed fasteners on door faces or face frames.

    C. All-Welded Metal Lockers: Connect groups together with standard fasteners, with no exposed fasteners on face frames.

    D. Equipment and Accessories: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates.

    1. Attach hooks with at least two fasteners. 2. Attach door locks on doors using security-type fasteners.

  • 134-18 Woodville Tompkins HS Additions

    METAL LOCKERS 10 5000

    3. Identification Plates: Identify metal lockers with identification indicated on Drawings. a. Attach plates to each locker door, near top, centered, with at least two aluminum

    rivets.

    b. Attach plates to upper shelf of each open-front metal locker, centered, with a least two aluminum rivets.

    4. Attach recess trim to recessed metal lockers with concealed clips. 5. Attach filler panels with concealed fasteners. Locate filler panels where indicated on

    Drawings.

    6. Attach sloping-top units to metal lockers, with closures at exposed ends. 7. Attach boxed end panels with concealed fasteners to conceal exposed ends of

    nonrecessed metal lockers.

    8. Attach finished end panels with fasteners only at perimeter to conceal exposed ends of nonrecessed metal lockers.

    3.3 ADJUSTING, CLEANING, AND PROTECTION

    A. Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding.

    B. Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit use during construction.

    C. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by locker

    manufacturer.

    END OF SECTION 10500

  • 134-18 Woodville Tompkins HS Additions

    UTILITY SHELVING 10 6170

    SECTION 10 6170

    UTILITY SHELVING

    PART 1 - GENERAL

    1.01 RELATED DOCUMENTS

    A. Drawings and general provisions of Contract, including General and Supplementary Conditions and

    Division 1 Specification sections, apply to work of this Section.

    1.02 DESCRIPTION

    A. Work Included: Install pre-manufactured wood storage shelving labeled on drawing as miscellaneous

    shelving.

    B. Provide within a 2” of wall and 12” latch side of doors to all elevations (4) walls.

    1. Janitors closets only provide one (1) unit 72” tall five (5) shelves 42” long

    1.03 SUBMITTALS

    A. Shop Drawings:

    1. Submit shop drawings for storage units, identified with location, materials and finishes.

    2. Indicate materials, methods of assembly and jointing, thickness of parts, location and type of

    hardware.

    3. Take measurements at the site for space where each item is to be placed.

    B. Product Data: Submit manufacturer’s detailed product description. Indicate unit construction including

    finishes.

    1.04 DELIVERY, STORAGE AND HANDLING

    A. Deliver storage units only after building is enclosed and wet operations in building are completed.

    B. Protect finished surfaces from soiling and damage during handling and installation.

    PART 2 - PRODUCTS

    2.01 ACCEPTABLE MANUFACTURERS

    A. Excalibur Shelving Systems

    B. Palmetto Shelving Systems, Inc. (803) 781-9955

    C. Leonard Peterson, “Reagent , storage system”

    2.02 MATERIALS AND COMPONENTS

    A. Uptights: Hemlock or Douglas Fir (1-5/8” x 1-5/8”)

    1. 3/8” x 5/8” deep plow entire length of stiles to receive shelf end channels with 3/16” drilled holes on

    1” centers. Uptights to be sufficient height for shelving to be 84” high.

    2. Stiles are to be locked together with three or more cross members mortised glued and pinned into the

    stiles.

  • 134-18 Woodville Tompkins HS Additions

    UTILITY SHELVING 10 6170

    3. All components are to be machined smooth with all outside corners eased.

    B. Shelves: ¾” pine shelf materials are to be machined to accept roll formed steel end channels shaped to fit

    over each end of the shelf and to rest on the shelf support pins. Finger joints are not acceptable.

    C. Shelf Support Pins: Non rusting alloy, 3/16” diameter x 1-14” long, 5/16” diameter head.

    D. “X” Braces: Two 18 gauge galvanized ¾” steel straps with holes punched at each end. Rivet straps at

    centers. One “X” brace required every three (3) sections.

    E. Back Panels: All back-to-back units for book storage to have 1/8” Abitibi S2S tempered hardboard back

    panels.

    F. Kickboard: Provide a 4” pine kickboard for each unit.

    G. Finish: Factory seal & lacquer (site finish is not acceptable)

    2.03 FABRICATION

    A. Manufacturer shelving in sizes as necessary to fit wall-to-wall as indicated on the drawings. Gaps in excess

    of 2” are not acceptable.

    B. Where dead corners are indicated on drawings, solid end panels will be required.

    C. Shelves shall not exceed 42” in length in general storage areas and 36” in book storage rooms. Shelves less

    than ¾” thick must be pre-approved (sample required) and may not exceed 30” in length.

    D. Unless otherwise indicated, all units shall receive 5 shelves over 84” high.

    PART 3 - EXECUTION

    3.01 SURFACE CONDITIONS

    A. Examine the areas and conditions under which work of this Section will be performed. Correct conditions

    detrimental to timely and proper completion of the work. Do not proceed until satisfactory conditions are

    corrected.

    3.02 INSTALLATION

    A. Install in strict accordance with manufacturer’s current instructions and approved shop drawings.

    B. Anchor all wall units.

    END OF SECTION 10670

  • 134-18 Woodville Tompkins HS Additions

    ALUMINUM WALKWAY COVERS 10 7300

    SECTION 10 7300

    ALUMINUM WALKWAY COVERS

    PART 1 - GENERAL

    1.1 SUMMARY

    A. Section includes Aluminum Walkway Covers and wall-mounted Canopy

    1.2 ACTION SUBMITTALS

    A. Product Data: For each type of product. 1. Include construction details, material descriptions, dimensions of individual components

    and profiles, operating characteristics, fittings, accessories, and finishes for Walkways

    and Canopies

    B. Delegated-Design Submittal: For Aluminum Walkway covers and wall mounted Canopies

    C. Delegated Design: Engage a qualified professional engineer, as defined in Section 014000 "Quality Requirements," to design Aluminum walkway covers and wall hung canopies

    assemblies.

    D. Structural Performance: Flagpole assemblies, including anchorages and supports, shall withstand design loads indicated within limits and under conditions indicated.

    1. Wind Loads: Determine according to NAAMM FP 1001. Basic wind speed for Project location is See structural drawings

    2. Design Data: Design calculations bearing the seal of a Registered Professional Engineer, licensed in the state where the project is located. Design calculations shall state that the

    canopy system design complies with the wind requirements of ASCE 7, the stability

    criteria of applicable building code, and all other governing criteria.

    3. Concrete Footings: Design footings capable of wind uplift and other loads. Show size and reinforcing required.

    E. SYSTEM DESCRIPTION

    F. Protective cover shall be all welded extruded aluminum system complete with internal drainage. Non-welded systems are not acceptable. Roll formed deck is not acceptable. Expansion joints

    shall be included to accommodate temperature changes of 120°F. Expansion joints shall have

    no metal-to-metal contact.

    1. Non-welled systems are not acceptable. 2. Bents larger than 12’-6” in the shortest dimension may be shipped KD. All other frames

    must be welded.

    3. Comply with the wind requirements of ASCE 7. 4. Provide an all welded extruded aluminum system complete with internal drainage. Non-

    welded systems are not acceptable.

  • 134-18 Woodville Tompkins HS Additions

    ALUMINUM WALKWAY COVERS 10 7300

    5. Provide expansion joints to accommodate temperature changes of 120 degrees F. Provide expansion joints with no metal to metal contact.

    6. Grout: Compressive strength of 2000 psi, minimum.

    1.3 QUALITY ASSURANCE

    A. A. Manufacturer Qualifications: At least ten years of experience in the design, fabrication, and erection of extruded aluminum canopy systems.

    1.4 CLOSEOUT SUBMITTALS

    A. Operation and Maintenance Data: For Walkways and Canopies to include in operation and maintenance manuals.

    PART 2 - PRODUCTS

    2.1 ALUMINUM WALL MOUNTED CANOPIES

    A. Manufactured aluminum canopies. wall mounted

    1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

    a. Mitchell Metals b. TVM- Tennessee Valley Metals c. Perfection d. Dittmer Architectural Aluminum

    B. General: 1. Shop Assembly: Assemble components in shop to greatest extent possible to minimize

    field assembly.

    2. Welding: In accordance with ANSI/AWS D1.2. 3. Bent Construction: Factory assemble beams to columns to form one-piece rigid bents.

    Where used make welds smooth and uniform using an inert gas shielded arc. Perform

    suitable edge preparation to assure 100% penetration. Grind welds only where interfering

    with adjoining structure to allow for flush connection. Field welding is not permitted.

    Rigid mechanical joints can be used if supported by engineering calculations and/or

    testing.

    4. Gutter Frame Construction: Factory assemble gutter fascia frames to form a one-piece welded frame. Make welds smooth and uniform using an inert gas shielded arc. Perform

    suitable edge preparation to assure 100% penetration. Grind welds only where interfering

    with adjoining structure to allow for flush connection. Field welding is not permitted.

    Gutter frames constructed by mechanically fastening components together are not

    acceptable.

    5. Deck Construction: Fabricate from extruded modules that interlock in a self-flashing manner. Positively fasten interlocking joints creating a monolithic structural unit capable

    of developing the full strength of the sections. The fastenings must have minimum shear

    http://www.specagent.com/Lookup?ulid=9060

  • 134-18 Woodville Tompkins HS Additions

    ALUMINUM WALKWAY COVERS 10 7300

    strength of 350 pounds each. Assemble deck with sufficient camber to offset dead load

    deflection.

    C. Columns: Provide radius-cornered tubular extrusions with cutout and internal diverter for drainage where indicated. Circular downspout opening in column not acceptable.

    D. Beams: Provide open-top tubular extrusion, top edges thickened for strength and designed to receive deck members in self-flashing manner.

    E. Deck: Extruded self-flashing sections interlocking into a composite unit. Provide welded plate closures at deck ends.

    F. Fascia: Manufacturer’s standard shape. Provide fascia splices where continuous runs of fascia are jointed. Locate splices to be in line with bents and fasten in place on hidden or non-vertical

    surfaces.

    G. Arches: For barrel vault protective covers, provide sharp-cornered tubular extrusions.

    H. Hanger Assemblies: Provide extruded aluminum hanger rods in manufacturer’s standard shapes and sized to meet the loads seen by canopy.

    2.2 Factory Finishing:

    A. Roof Deck: Finish designations prefixed by AA comply with system established by the AAMA for designating aluminum finishes.

    1. High performance Organic Coating Finish: AA-C12C42R1x (Chemical Finish: cleaned with inhibited chemicals; Chemical Finish: acid-chromate-fluoride-phosphate conversion

    coating; Organic Coating: as specified below). Prepare, pretreat, and apply coating to

    exposed metal surfaces to comply with coating and resin manufacturer’s written

    instructions.

    a. Fluoropolymer Two-Coat Coating System: Manufacturer’s standard two-coat, thermocured system consisting of specially formulated inhibitive primer and

    fluoropolymer color topcoat containing not less than 70 percent polyvinylidene

    fluoride resin by weight; complying with AAMA 2605.

    B. Columns Beams and Fascia Class I, Clear Anodic Finish: AA-M12C22A41 (Mechanical Finish: non-specular as fabricated; Chemical Finish: etched, medium matted, Anodic Coating:

    Architectural Class I, clear coating 0.7 mils or thicker),complying with AAMA 611.

    PART 3 - EXECUTION

    3.1 WALL MOUNT CANOPY INSTALLATION

    A. General: Install Canopies where shown and according to Shop Drawings and manufacturer's written instructions.

  • 134-18 Woodville Tompkins HS Additions

    ALUMINUM WALKWAY COVERS 10 7300

    B. Mounting Brackets and Bases: Anchor brackets and bases securely to structural support with fasteners as indicated on Shop Drawings.

    C. Erect canopy true to line, level, and plumb.

    D. B. Provide hairline miters and fitted joints.

    3.2 WALKWAY COVERS

    A. Verification of Conditions: Verify that all concrete, masonry, and roofing work in the vicinity is complete and cleaned.

    B. Erect protective cover true to line, level, and plumb. Protect aluminum columns embedded in concrete with clear acrylic. Fill downspout columns with grout to the discharge level to prevent

    standing water. Install weep holes at top of concrete in non-draining columns to remove

    condensation.

    C. Provide hairline miters and fitted joints.

    3.3 CLEANING

    A. A. Clean all canopy components promptly after installation.

    B. Protect materials during and after installation.

    END OF SECTION 10 7300

  • 134-18 Woodville Tompkins HS Additions

    TOILET, BATH AND MISCELLANEOUS ACCESSORIES 10 8000

    SECTION 10 8000

    TOILET, BATH AND MISCELLANEOUS ACCESSORIES

    PART 1 - GENERAL

    1.01 SUMMARY

    A. Related Work Specified Elsewhere:

    1. Drawings, General and Supplementary Conditions, Division-1 Specification sections, apply this

    Section.

    B. Work Included in this Section:

    1. Toilet Accessories:

    a. Mirrors (M).

    b. Paper Towel Dispenser (PTD).

    c. Toilet Tissue Dispenser (TTD).

    d. Paper Towel Receptacle (PTR).

    e. Soap Dispenser (SD).

    f. Grab Bar (GB).

    g. Electric Hand Dryer (EHD)

    2. Miscellaneous Accessories:

    a. Mop and Broom Holder (MBH).

    b. Baby Changing Station ( BCS)

    c. Defibrillator (AED)

    3. Bath and Shower Accessories:

    a. Soap Tray (ST)

    b. Towel Pin (TP)

    c. Robe Hook (RH)

    d. Shower Curtain Rod (SCR)

    e. Shower Curtain and Hooks (SCH)

    f. Folding Shower Seat (FS)

    1.02 QUALITY ASSURANCE

    A. Inserts, Anchorages: Furnish devices to be set in concrete or masonry; coordinate delivery with other

    work.

    B. Accessory Locations: Coordinate with other work to avoid interference, assure proper operation, servicing

    of accessories.

    1.03 SUBMITTALS

    A. Product Data: Manufacturer's technical data, installation instructions for each unit.

    B. Samples: Full-size samples of units to Architect for review of design, operation; acceptable samples

    returned to Contractor for use in Project.

    C. Shop Drawings: Setting drawings, templates, instructions, directions for installation of anchorage

    devices, cut-out requirements in other work.

  • 134-18 Woodville Tompkins HS Additions

    TOILET, BATH AND MISCELLANEOUS ACCESSORIES 10 8000

    PART 2 - PRODUCTS

    2.01 ACCEPTABLE MANUFACTURERS

    A. Manufacturer: Subject to compliance with requirements, provide toilet accessories by one of following:

    1. General Accessories:

    a. American Specialties, Inc.

    b. Bobrick Washroom Equipment, Inc.

    c. Bradley Corp.

    2.02 MATERIALS, GENERAL

    A. Stainless Steel: AISI Type 302/304, No. 4 finish, 22 gage (.034") min. unless otherwise indicated.

    B. Brass: Leaded and unleaded, flat products, FS QQ-B-613; Rods, shapes, forgings, flat products with finished

    edges, FS QQ-B-626.

    C. Sheet Steel: Cold rolled, commercial quality ASTM A 366, 20-gage (.040") min., unless otherwise indicated;

    surface preparation, metal pretreatment for applied finish.

    D. Galvanized Steel Sheet: ASTM A 527, G60.

    E. Galvanized Steel Mounting Devices: ASTM A 153, hot-dip galvanized after fabrication.

    F. Fasteners: Screws, bolts, other devices, of same material as unit or galvanized steel where concealed.

    2.03 FABRICATION

    A. General:

    1. No names labels permitted on exposed faces.

    2. On interior surface not exposed to view or on back surface, identify item by printed, waterproof label

    or stamped nameplate with manufacturer's name, product model number.

    B. Surface-Mounted Units, General:

    1. Except where otherwise indicated, fabricate units with tight seams, joints, roll exposed edges.

    2. Hang doors, access panels with full length stainless steel piano hinge.

    3. Conceal anchor


Recommended