For Internal Use: FI.PK.FIT.317_WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_Guide_Rev1.indd
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
3.
Unit shown for illustration purposes only.
2.1.
Unit shown for illustration purposes only.
Side view Side view
Unit shown for illustration purposes only.
Traditional / ClassicCornice
Stepped Traditional / ClassicCornice
Traditional / Classic Cornice 1. Straight cut - Pages 1-4 2. External mitre joint - Pages 5-8 3. Internal mitre joint - Page 9-11
Contents:
4. Final Fit - Page 22
Stepped Traditional / Classic Cornice 1. Straight cut - Pages 12- 14 2. External mitre joint - Pages 15-18 3. Internal mitre joint - Page 19-21
Straight Cut Internal Mitre
External Mitre
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 1
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Throughout the following installation guide the parts that make up this stacked traditional/classic cornice will be labelled as per the illustration on the left. Please note part D is applicable on the classic cornice only.
BEFORE YOU START
INSTALLATION SHOULD BE
PERFORMED BY A COMPETENT
PERSON ONLY.
THIS PRODUCT COULDBE DANGEROUSIF INCORRECTLY
INSTALLED
B A
C
D
Please note the stacked traditional/classic cornice should be fully assembled at
ground level then lifted into position.
200
mm
Classic Cornice Maximum height
126
mm
Classic Cornice Minimum height
200m
m
Traditional Cornice Maximum height
Please note that the stacked traditional/classic cornice has a minimum and
maximum height limitation as below.
Unit shown for illustration purposes only.
Side view
Traditional / Classic Cornice Pages 1 - 11
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 2
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Measurement
Step 1.Measure the distance from each end of the wall units.
Step 2.Apply the measurment to part A and cut to size.
Measurement
A
A Apply measurement to this face
Step 3.Measure the inside face of part A.
Step 4.Apply measurement to the front edge of part B.
Apply measurement to this face
B
Viewed from behind
Straight Length
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 3
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
B
Step 5.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.
A
A
B
Step 6.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked cornice will be positioned. Please refer to the minimum and maximum positions on page 1
Stacked cornice is adjustable along part A
MeasurementStep 7.Measure the outside face of part A.
A
B
Viewed from behind
Please note: if part C sits lower then part A then part A should be
cut down to size.
A CCut
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 4
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Apply measurement to this face
Step 8.Apply measurement to the inside face of part C and cut to size.
Step 9.Apply adhesive to the back of part C. Fix part C into position using 30mm screws.
Step 10.If using the classic traditional cornice repeat steps 7-9. Make sure the top face of part D is touching the bottom face of part C.
Apply measurement to this face
DInside Face
Viewed from behind
A
C
DFlush
C
C
A
B
Adhesive
Viewed from behind
C
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 5
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
AMeasurement
Inside Face
Step 13.Measure the inside face of part A (from the wall to the internal mitre).
Measurement
Apply measurement to this face
A
Step 11.Measure the distance from the wall to the front face of the decor end.
Step 12.Apply the measurement to part A and cut to size. Mitre cut the front edge (that will line up with the doors) at a 45° angle.
Plan View
Measurement
A
Viewed from behind
External Mitre Joint
Example of external mitre joint.Unit shown for illustration purposes only.
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 6
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 15.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.
Step 16.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked cornice will be positioned. Please refer to the minimum and maximum positions on page 1
Stacked cornice is adjustable along part A
Viewed from behind
B
B
Apply measurement to this face
Step 14.Apply measurement to the front edge of part B, mitre at a 45° angle.
A
Please note: if part C sits lower then part A then part A should be
cut down to size.
A CCut
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 7
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 18.Apply measurement to the inside face of part C and cut to size. Part C should be mitred at a 45° angle, make sure to add extra material to the measurement in order to achieve the required mitre joint (see illustration right).
Apply measurement to this faceC
Viewed from behind
Measurement Extra for mitre
C
A
B Plan View
Viewed from behind
Step 19.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.
C
B
Adhesive
Measurement BStep 17.Measure the outside face of part A.
A
A
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 8
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 20.If using the classic cornice repeat steps 17-19. Make sure the top face of part D is touching the bottom face of part C.
Apply measurement to this face
DInside Face
Viewed from behind
A
C
DFlush
Step 21.Repeat steps 11 - 20 to build the next adjoining cornice.
Step 22.Apply mitre adhesive to each of the mitred joints and fix together. Make sure all the mitred joints are aligned properly.
Viewed from behind
Mitre Adhesive
Assembly should be carried out at ground level and lifted into place in one piece.
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 9
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Ai Aii
Measurement Measurement
Step 23.Take measurements from the outside face of the units to the adjacent corner points (as per illustration on the left). The front face of part A must be flush with the front face of the doors
A
DO
OR
Flus
h
Step 25.Screw through the inside face of part Ai into Aii using 30mm screws fixing both parts together.
Step 24.Cut parts A to size
Aii
AiAii
Ai
Viewed from behind
Internal Mitre Joint
Example of internal mitre joint.Unit shown for illustration purposes only.
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 10
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
B B
Measurement
Measurement
Step 26.Measure the inside face of parts A as per the illustrationabove. Apply these measurements to parts B and cut to size.
AA
Step 27.Fix parts A and B together using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.
BB
Measurement Measurement
Step 28.Measure the outside face of part A
A A
Viewed from behind
Aii Ai
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 11
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 30.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.
Step 31.If using the classic cornice repeat steps 28-30. Make sure the top face of part D is touching the bottom face of part C.
Apply measurement to this face
DInside Face
Viewed from behind
A
C
DFlush
Apply measurement to this faceC
Viewed from behind
Measurement
CPlan View
Step 29.Apply measurements to the inside face of part C and cut to size. Part C should be mitred at a 45° angle.
Viewed from behind
C
B
AAdhesive
C
For final fitting instruction please turn to page 22
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 12
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Please note that the stepped traditional/classic Cornice has a minimum and
maximum height limitation see below.
Measurement
Step33.Measure the distance from each end of the wall units.
Step 34.Apply the measurement to part A and cut to size.
A Apply measurement to this face
Step 35.Measure the inside face of part A.
Measurement
A
Viewed from behind
219
mm
219
mm
145
mm
Traditional Cornice Maximum height Classic Cornice Maximum height Classic Cornice Minimum height
Stepped Traditional / Classic Cornice
Pages 12 - 21
Unit shown for illustration purposes only.
Side view
Straight Length
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 13
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 36.Apply measurement to the front edge of part B.
Apply measurement to this face
B
Step 37.Placing parts A on top of parts B fix together using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws. Make sure there is a 21mm from the front of part A to the front of part B.
A
B
Step 38.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked Cornice will be positioned. Please refer to the minimum and maximum positions on page 12
Stacked Cornice is adjustable along part A
B
AViewed from behind
B
A
21mm
Please note: if part C sits lower then part A then part A should be
cut down to size.
A CCut
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 14
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Measurement
AB
Step 39.Measure the outside face of part A.
Step 40.Apply measurement to the inside face of part C and cut to size.
Viewed from behind
Step 41.Apply adhesive to the back of part C. Fix part C into position using 30mm screws.
C
A
B
Adhesive
C
Apply measurement to this faceC
Step 42.If using the classic traditional Cornice repeat steps 39-41. Make sure the top face of part D is touching the bottom face of part C.
Apply measurement to this face
DInside Face
Viewed from behind
A
C
DFlush
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 15
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Measurement
Apply measurement to this face
Step 43.Measure the distance from the wall to the front face of the decor end.
Step 44.Apply the measurement to part A and cut to size. Mitre cut the front edge (that will line up with the doors) at a 45° angle.
Plan View
Measurement
A
Step 45.Measure the outside face of part A (from the wall to the external mitre) and add 21mm.
Measurement +21mm
A
OUTSIDE FACE
External Mitre Joint
Example of external mitre joint.Unit shown for illustration purposes only.
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 16
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 47.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.
Make sure there is a 21mm gap between the front faces of parts A and B.
Viewed from behind
B
B
Apply measurement to this face
Step 46.Apply measurement to the front edge of part B, mitre at a 45° angle.
A
Step 48.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked Cornice will be positioned. Please refer to the minimum and maximum positions on page 12
Stacked Cornice is adjustable along part A
B
A
21mm
Please note: if part C sits lower then part A then part A should be
cut down to size.
A CCut
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 17
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 50.Apply measurement to the inside face of part C and cut to size. Part C should be mitred at a 45° angle, make sure to add extra material to the measurement in order to achieve the required mitre joint (see illustration right).
Apply measurement to this faceC
Viewed from behind
Measurement Extra for mitre
C
A
B
Plan View
Viewed from behind
Step 51.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.
C
B
Adhesive
Measurement
BStep 49.Measure the outside face of part A.
A
A
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 18
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 52.If using the classic cornice repeat steps 49-51. Make sure the top face of part D is touching the bottom face of part C.
Apply measurement to this face
DInside Face
Viewed from behind
A
C
DFlush
Step 53.Repeat steps 43 - 51 to build the next adjoining cornice.
Step 54.Apply mitre adhesive to each of the mitred joints and fix together. Make sure all the mitred joints are aligned properly.
Viewed from behind
Mitre Adhesive
Assembly should be carried out at ground level and lifted into place in one piece.
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 19
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Ai Aii
Measurement Measurement
Step 55.Take measurements from the outside face of the units to the adjacent corner points (as per illustration on the left). The front face of part A must be flush with the front face of the doors
A
DO
OR
Flus
h
Step 57.Screw through the inside face of part Ai into Aii using 30mm screws fixing both parts together.
Step 56.Cut parts A to size
AiAii
AiiAi
Viewed from behind
Internal Mitre Joint
Example of internal mitre joint.Unit shown for illustration purposes only.
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 20
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 58.Measure the outside face of parts A as per the illustration above.
B
Viewed from behind
Measurement
AiiAiMeasurement
Apply measurement to this face
B
Measurement Extra for
mitre
B
Plan View
Step 59.Apply measurement to the front face of part B and cut to size. Part B should be mitred at a 45° angle, make sure to add extra material to the measurement in order to achieve the required mitre joint (see illustration above).
B
A
21mm
Step 60.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 15mm screws.
Make sure there is a 21mm gap between the front faces of parts A and B.
B
Aii Ai
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 21
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 61.Measure the outside face of part A.
Measurement Measurement
A A
Step 64.If using the classic cornice moulding repeat steps 61-63. Make sure the top face of part D is touching the bottom face of part C.
Apply measurement to this face
DInside Face
Viewed from behind
A
C
DFlush
Apply measurement to this faceC
Viewed from behind
Step 63.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.
Adhesive
Viewed from behind
C
B
A
Measurement
CPlan View
Step 62.Apply measurements to the inside face of part C and cut to size. Part C should be mitred at a 45° angle.
For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 22
STACKED TRAD/CLASSICCORNICE
FITTING GUIDE
Step 66.Secure the stacked cornice in place by screwing up through the unit top fixed shelves into part B using 30mm screws. Conceal the screw heads using the screw caps provided.
Do
or/
Dec
or
end
Part A
Flus
h
Final Fit
Step 65.Lift the assembled stacked cornice onto the top of the wall units making sure the outside face of Part A is flush with the decor end/doors. Please note this step should be carried out by a minimum of two people.