+ All Categories
Home > Documents > State of Georgia S&St CttServer & Storage...

State of Georgia S&St CttServer & Storage...

Date post: 10-Jul-2020
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
57
State of Georgia S & St C t t Server & Storage Contract Technical Presentation April 2011 Technical Presentation
Transcript
Page 1: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

State of Georgia S & St C t tServer & Storage Contract

Technical PresentationApril 2011

Technical Presentation

Page 2: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Agenda & IntroductionContract Overview – Russ Boles

System x & BladeCenter Servers – Dave Laubscher

Power System Servers – Cindy Henricks

Storage Scott VenutiStorage – Scott Venuti

Slide 2

Page 3: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

D L b h

IBM System x and BladeCenter Update

Dave [email protected]

Page 4: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

x86 Trends

IBM Innovation

Systems & SolutionsSystems & Solutions

Slide 4

Page 5: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Processor Roadmap20102009 201120102009 2011

Dunnington (74xx)45nm

Nehalem EX (75xx)Nehalem EX (65xx)

45nm

Westmere EX32nm

7000 Series 4+ Socket

90, 130W

Intel Core Microarchitecture, Intel I/OAT, Dedicated high speed FSB

4-8 Core, QPI / Direct Attach Memory

95, 130W

6-10 Core, 4 QPI Links, 3MB L2/core

90, 130W

Nehalem EP (55xx)45nm

Westmere EP (56xx)32nm

5000 Series 2 Socket

QPI / Direct Attach Memory

60, 80, 130W

6 Core, 2MB L2/core

95, 130W

2xxx/6xxx6- Core

Istanbul45nm

Magny-Cours (6xxx)45nm

8-12- Core

Slide 5

Quad Core Six Core

2xxx/6xxx Series 79 (55), 115 (75) , 137 (105)W 79 (55), 115 (75) , 137 (105)W

> Six Core

Page 6: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Next Generation Intel® Xeon Processor

Westmere-EP Up to 6 cores / 12 threads per socket with Hyper threading

Based on 32nm process technologyBased on 32nm process technology

12 MB shared cache

Intel Turbo Boost Optimization

Two QPI Links (only 1 is coherent link) per socketTwo QPI Links (only 1 is coherent link) per socket

One integrated memory controller (IMC)

DDR3L support, three DDR channels per socket

Westmere-EX Up to 10 cores/ 20 threads per socket, Nehalem core, 45 nm process, 24MB shared L3

SMT ( H Th di )SMT (~Hyper-Threading)

Turbo Boost

Four QPI Links (3 coherent)

T i t t d t ll (IMC)

Slide 6

Two integrated memory controllers (IMC)

Four buffered memory channels per socket

Page 7: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Enhanced RAS Characteristics

Slide 7http://www.intel.com/Assets/en_US/PDF/whitepaper/323479.pdf

Page 8: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

x86 Trends

IBM Innovation

Systems & SolutionsSystems & Solutions

Slide 8

Page 9: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

IBM X-Architecture™A d i bl i t f b ildi IBM t i bilitA design blueprint for building proven IBM enterprise capability

into the industry-standard System x product line

Industry Standard Technologies

System x™

Ease of Use Industry Standard Technologies

System Storage™System z™POWER Systems™

iDataPlex™

BladeCenter®

VirtualizationScalabilityReliabilityEfficiency

Availability

Slide 9

Page 10: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

eX5 Portfolio - Systems for a Smarter Planet

Consolidation, virtualization, and database workloads being migrated off

System x3850 X5

database workloads being migrated off of proprietary hardware are demanding more addressability

4U / 4-Way

Powerful and scalable system allows some workloads to migrate onto 2 socket design that delivers enterprise

System x3690 X5

Broad coverage for most enterprise applications, server

Scalable

BladeCenter HX5

computing in a dense package

consolidation, virtualized workload enablement.

Demand for minimum footprint as well as integrated networking infrastructure has increased the growth of the blade form factor.

Slide 10

Page 11: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

MAX 5 Doubles Memory Capacity

MAX 5 Features:Expand memory capacityy yUp to double the number of memory DIMMs than the competitorsNo impact to memory latencyOver five times the memory capacity in two sockets vs. today’s leading two-socket systemsMAX5 b titi d t CPUMAX5 memory may be partitioned to CPUs or pooled

Provides the memory customers have neededProvides the memory customers have needed for database and virtualization – up to 100%

more virtual machines

Allows higher memory capacity to be reached

Slide 11

with less expensive DIMMs for more economical high end implementations

Page 12: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

eX5 is RIGHT for your workloads today, and it’s the only platform that can grow with your business

Memory Expansion 8P, 192DIMMand Scaling with MAX5 (1H 2011)

Native (QPI) Scaling4P, 32D

8P, 128DIMM

Memory Expansionwith MAX5

2P 40D

2P, 64DIMM4P, 96DIMM

Base System

2P, 40D

2P, 32DIMM4P, 64DIMM

Slide 12

2P, 16D

HX5 x3850 X5 x3690 X5

Page 13: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Maximize memoryThe new eX5 portfolio provides as much as twice the amount of

8-socket4-socket2-socket

memory as competitive systems

200200192

6TB

10096

128

2TB

3TB

3240

64 64

MM

s

18DIM

Slide 13

Page 14: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Minimize costEliminate the memory bottleneck and minimize VMware y

licensing costs

82%more VMs

Same 2S license cost 50%license cost

Same number of VMs

x3690 X5 with MAX5 x3690 X5 with MAX5

2S Non IBM server4S Non-IBM server

2S Non-IBM server

Slide 14

Software licensing costs for VMware Enterprise Plus Cost: $3,500 per processor. Memory is constrained before processors are fully utilized.

Page 15: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Minimize costReduce Microsoft SQL software licensing costs by 50 percent using

X5 t h leX5 technology

A 1,000 user SQL Server 2008 database using a two-socket Nehalem-EX system.

Non IBM Nehalem EX ser erNon-IBM Nehalem-EX server System x3690 X5 2-socket Nehalem-EX server

50%50%license cost

Same number of users

SQL Server 2008 Enterprise Edition licensing cost SQL Server 2008 Enterprise Edition licensing cost

US$100,000 US$50,000

Slide 15

Notes:All pricing shown is Microsoft List Pricing as of January 2010 per the pricing information on http://www.microsoft.com/sqlserver/2008/en/us/pricing.aspxPricing model used is per processor licensing which is based on $24,999 per physical socket on the server (logical cores are not counted)

Page 16: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Light Path DiagnosticsLocate and diagnose hardware problems quickly

Exclusive - Rapid Fault Isolation

avoiding or significantly reducing downtime

Works at hardware level – no OS required

Continued Enhancements• Innovative slide-out panel – rack servers

• Exclusive front cover panel – tower servers

• Remind Button• Remind Button

• Persistent Light Path

!.

Slide 16

Page 17: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

IBM Innovation in Energy Efficient Technologygy

Slide 17

Page 18: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Increased hardware utilization through Virtual Fabric

Virtual FabricAdapter

Virtual FabricvNIC 1 = 1Gb

vNIC 2 = 3.5Gb

vNIC 3 = 5GbFCoE = 5GbpvNIC 4 = 500Mb

vNIC 1 = 1Gb

vNIC 2 = 3.5Gb

vNIC 3 = 5Gb

vNIC 4 = 500Mb BNT Virtual Fabric 10Gb FCoE = 5Gb

Switch Module

System x Servers:

CNAvNIC

vNIC 1 = 1Gb

vNIC 2 = 3.5Gb

vNIC 4 = 500Mb

vNIC 3 = 5Gb

vNIC 1 = 1Gb

vNIC 2 = 3.5Gb

vNIC 4 = 500Mb

BNT RackSwitch™ G8124vNIC 3 = 5Gb

Slide 18

• Reducing switch, cable and adapter costs and achieving better energy efficiency• Allocate and adjust bandwidth based on actual requirements

Page 19: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

x86 Trends

IBM Innovation

Systems & SolutionsSystems & Solutions

Slide 19

Page 20: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Dynamic Infrastructure with System x & BladeCenter“Fit for Purpose”Fit for Purpose

Enterprise

Server Consolidation, Virtualization

iDataPlex

p

BladeCenter

Infrastructure Simplification

Virtualization

Web 2.0, HPC

Scale Out

Scal

eU

p Simplification, Application

Serving

HPC, Grid, Energy

Efficiency

Scale Out

Stand alone & Multiple

Applications

Slide 20

Rack and Tower

Page 21: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

x3850 X5: 4-socket 4U x86 (Nehalem EX) platform

(2x) 1975W Rear Access Hot Swap, Redundant P/S

(8x) Memory Cards for 64 DIMMs –8 1066MHz DDR3 DIMMs per card 6x - PCIe Gen2 Slots

(+2 additional)

2x 10Gb Ethernet Adapter

(+2 additional)

(4x) Intel Xeon CPU’s

RAID (0/1) standard

2x 60mm Hot Swap Fans

(8x) Gen2 2.5” Drives or

(2x) 120mm Hot Swap Fans

RAID (0/1) standard, RAID 5/6 Optional

DVD Drive

Slide 21

( )2 FlashPacks

Dual USB Light Path Diagnostics

DVD Drive

Page 22: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

x3690 X5: 2-socket 2U (Nehalem EX) platform

(1x) x16 (full height, full length or (2x) x8 (1 full size, 1 full height / half length)

(2x) PCIe x8 Low Profile(1x) PCIe x4 Low Profile for RAID

Scaling ports

(4x) N+N 675W Rear Access Hot Swap Redundant P/S

32 x DDR3 Memory DIMMs16 in upper mezzanine (pictured)16 below

Light Path Diagnostics

8x Memory Buffers

DVD Drive

(16x) Gen2 2.5” Drives or3 FlashPacks

(4x) 60mm Hot Swap Fans

Dual USB

Slide 22

3 FlashPacks

Page 23: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

MAX5 for x3690 X5 and x3850 X5

Lightpath Diagnostics

Hot swap fans System removes from chassis for easy access

32 Memory DIMMs

chassis for easy access

QPI Ports

Firehawk Chipset

EXA Ports

p

QPI attaches to systems

EXA Scalability to other memory drawers

Slide 2323

Memory Buffers

drawers

Page 24: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Dynamic Infrastructure with System x & BladeCenter“Fit for Purpose”Fit for Purpose

Enterprise

Server Consolidation, Virtualization

iDataPlex

p

BladeCenter

Infrastructure Simplification

Virtualization

Web 2.0, HPC

Scale Out

Scal

eU

p Simplification, Application

Serving

HPC, Grid, Energy

Efficiency

Scale Out

Stand alone & Multiple

Applications

Slide 24

Rack and Tower

Page 25: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

System x High Volume Portfolio

x3650 M3The Ultimate Business

x3550 M3General Business

x3500 M3 Business Critical

x3400 M3General Business with

Exceptional quality, value, performance and ease of use from the trusted leader

x3755 M34 Sockets with The Ultimate Business

Critical ServerGeneral Business Compact Server

Business Critical Tower Server

General Business with Enterprise Features

4 Sockets with 2 Socket Economics

x3250 M3x3620 M3 x3200 M3x3630 M3 x3250 M3Big Performance

at Entry Value

x3620 M3The Value

Storage Server

x3200 M3Entry Value

Business Engine

x3630 M3The Storage

Dense Server

Leadership Brand, Quality & Service

Delivering Value

Leading Technology

Slide 25

Delivering ValueEasy to Deploy, Manage & Service

Page 26: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

System x3630 M32-Socket, 2U, storage-rich

Maximizing internal storage density for companies on tight budgets2U St Ri h S

A New Approach Delivering Lowest Cost per Terabyte

, , g

2U Storage Rich Sever –High capacity, choice of low cost 3.5” HDDs or 2.5” HDDs, supporting up to 28TB storage, provides large storage capacity without going external

3630 M3x3630 M3

Processor Support two 40W-95W Westmere processors, up to 2.66GHz (4-core) & 2.93GHz (6-core)Support two 80W Xeon 5500 Series Processors, up to 2.26GHz (4-core)

Memory Support 2DPC @ 1333MHz for Westmere CPU SKUSupport 12 RDIMM (1.5V and 1.35V) up to 96 GB of memorySupport 12 RDIMM (1.5V and 1.35V), up to 96 GB of memory

StorageSupport up to 14x 3.5" Hot Swap SAS/SATA HDDs or up to 28x 2.5" Hot Swap SAS/SATA HDDsSupport SAS/SATA (Allow mixing different drives), up to 28TB diskSupport 6Gbps RAID infrastructure – backplane, RAID card

ModelD fi iti

Support Westmere and select Nehalem CPU SKUsS t 6Gb RAID d t H t S d lDefinition Support 6Gbps RAID adapter on Hot Swap models

Power Supply Redundant power supply base 1x675W (Added PSU options for field upgrade to redundancy)

System Mngt IBM Tools support – IBM Director, ToolsCenter, and IMM

Service WW Enablement (3 year onsite world class support standard)

Slide 26

( y pp )

Workloads Backup server, Web 2.0, Imagery, Video/Photo sharing, On-line gaming, Blog, Messaging, Web searching, Video recording, Mail server (Notes and Exchange), Transactional data, File/Print

Page 27: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

The Dual-Socket 2U IBM x3620 M3

Provides a value offering that balances cost and function

Cost Optimized Alternative Dual-Socket 2U Server

Choice of SW or full HW advanced RAIDBasic or full redundancy, LV, 80, and 95W procs, SS SATA or HS SASSS SATA or HS SAS

x3620 M3

Processor Support two 40W-95W Westmere processors, up to 2.66GHz (4-core) & 2.93GHz (6-core)Support two 80W Xeon 5500 Series Processors, up to 2.26GHz (4-core)

Support 2DPC @ 1333MHz for Westmere CPU SKUMemory Support 2DPC @ 1333MHz for Westmere CPU SKUSupport 12 RDIMM (1.5V and 1.35V), up to 96 GB of memory

StorageSupport up to 4x 3.5" Simple Swap SATA HDDs or up to 8x 3.5" Hot Swap SAS/SATA HDDsSupport SAS/SATA (Allow mixing different drives), up to 16TB diskSupport 6Gbps RAID infrastructure – backplane, RAID card

ModelDefinition

Support Westmere and select Nehalem CPU SKUsSupport SW RAID for Simple Swap modelSupport 6Gbps RAID and low cost 3Gbps RAID adapter on Hot Swap models

Power Supply Redundant power supply base 1x675W (Added PSU options for field upgrade to redundancy)

Slide 27

System Mngt IBM Tools support – IBM Director, ToolsCenter, and IMM

Service WW Enablement (3 year onsite world class support standard)

Page 28: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Dynamic Infrastructure with System x & BladeCenter“Fit for Purpose”Fit for Purpose

Enterprise

Server Consolidation, Virtualization

iDataPlex

BladeCenter

Infrastructurep

Virtualization

Web 2.0, HPC Infrastructure

Simplification, Application

Serving

Scale Out

Scal

eU

pHPC, Grid, Energy

Efficiency

Scale Out

Stand alone & Multiple

Applications

Slide 28

Rack and Tower

Page 29: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

iDataPlex – Innovative Design

Rotated the rack 90 degrees• Doubles the density in same

footprint p• Half depth, front-access servers

- Low air-flow impedance• Greater cross-section for RDHx

100 U Rack100 U Rack• 16 Vertical U for switches and

PDU’s

1200mm4 4

1280mm

TOne

600mm (840mm w/RDHx)

1200mm

446 x 520m

446 x 520m

1020mm

444 x 700mm

444 x 700mm

1050mm

Two Standard 19” Racks

iDataPlex Rack

Slide 29

w/RDHx)mm

mm

m

Page 30: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Dynamic Infrastructure with System x & BladeCenter“Fit for Purpose”Fit for Purpose

Enterprise &

Server Consolidation, Virtualization

iDataPlex

p

BladeCenter

Infrastructure Simplification

Virtualization

Web 2.0, HPC

Scale Out

Scal

eU

p Simplification, Application

Serving

HPC, Grid, Energy

Efficiency

Scale Out

Stand alone Applications

Slide 30

Rack and Tower

Page 31: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Extend blade benefits to your entire businessChassis tailored to your specific needs…

New Models withNew Models with 2320W PS

Upgrades for existing BC E

New More efficient 2980W PS

IBM BladeCenter EEnterprise, best energy,

best density IBM BladeCenter TRuggedized

IBM BladeCenter S

Upgrades for existing BC H

IBM BladeCenter HTRuggedized,

high performance

IBM BladeCenter HHigh performance

IBM BladeCenter SDistributed, small office,

easy to configure

110v Power!

A common set of blades

A common set of industry-standard switches and I/O fabrics

Slide 31

A common management infrastructurehttp://www.80plus.org/manu/psu/psu_detail.aspx?id=111&type=1

Page 32: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

IBM BladeCenter x86 Blade Servers HS12

Most affordable blade for single-threaded apps

HS22“No Compromise” Enterprise Blade

HS22VHigh performance virtualization blade

1 Socket 2 Socket 2 Socket

New!

1 SocketProc: Xeon QCMem: 6 DIMM / 24GBHDD: 2 HS

Key Features

2 SocketProc: Xeon QCMem: 12 DIMM / 192GBHDD: 2 HS

Key Features

2 SocketProc: Xeon QCMem: 18 DIMM / 288GBSSD: 2

y• 2 hot-swap HDDs• SAS/SATA/SSD• Optional battery backed cache

• Max mem per socket

y• 2 HS HDDs with choice of SAS or SSD• Large memory on a blade• Embedded hypervisor• Battery-backed cache option• IMM

Key Features• 2P, 18 DIMMs• 2 SSDs in 30mm• Embedded hypervisor• Maximum memory• IMM

Sample Applications

• E-mail / CollaborationH t d Cli t

Sample Applications• Virtualization• E-mail/CollaborationH t d Cli t

Sample Applications

Vi t li ti

Slide 32

• Hosted Client• Web Serving

• Hosted Client• Web Serving

• Virtualization• E-mail/Collaboration• Hosted Client• Web Serving

Page 33: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

HS22 Blade Optional RAID 5w/ battery-backedwrite back cache

“No compromise” next generation enterprise blade

Internal USB(Embedded Hypervisor)

write-back cache

Dual GbE LOM(5709S)

2x Intel Xeon 5600 Processors(Westmere EP)

(Embedded Hypervisor) (5709S)

What makes the HS22 special?What makes the HS22 special?

Additional FeaturesIMM & UEFI

p•Uses Tylersburg 36 chipset (vs. Tylersburg-24)•More PCI lanes for expansion (x8 vs x4)•Support for more 10G networks

p•Uses Tylersburg 36 chipset (vs. Tylersburg-24)•More PCI lanes for expansion (x8 vs x4)•Support for more 10G networks

2 I/O E i Sl t

IMM & UEFILight Path Diagnostics

TPM 1.2Expansion blades

BCE, BCH, BCS, BCHT

pp•Supports 130W processors

pp•Supports 130W processors

2 I/O Expansion Slots(1x CIOv + 1x CFFh)

Slide 33

2x hot-swap drive bays(SAS or Solid State)

12x VLP DDR3 Memory(192GB Max / 1333MHz Max)

Page 34: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

HS22V DetailMax memory DP blade for virtualization and HPCMax memory DP blade for virtualization and HPC

Internal USB(Embedded Hypervisor)

Dual 1GbE LOM

2x EPProcessors

What makes the HS22V special?•Uses Tylersburg 36 chipset•Supports 130W processors•Internal SSDs HW RAID protected

What makes the HS22V special?•Uses Tylersburg 36 chipset•Supports 130W processors•Internal SSDs HW RAID protected

Same I/O as HS22(1x CIOv + 1x CFFh)

Additional Features

pp

2x 1.8” SSDNHS RAID 0/1

Additional FeaturesIMM & UEFIPState CappingTPM 1.2Light Path DiagnosticsPCI E i Bl d

Slide 34

NHS RAID 0/118x VLP DDR3 Memory

(288GB Max / 1333MHz Max)

PCI Expansion Blade2DPC @ 1333MHz

Page 35: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

HX5 Blade

2x Intel Nehalem-EX

16x VLP DDR3 Memory

2x SSD drives (1.8”)

2x Intel Nehalem EXProcessors

Dual & redundant

I/O and Power

Slide 35

2x IO Expansion Slots(1x CIOv + 1x CFFh)

Page 36: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

HX5 4-Socket Blade4x IO Expansion Slots

4x Intel Xeon 7500

4x IO Expansion Slots(2x CIOv + 2x CFFh)

32x VLP DDR3 Memory (16 per node)4x SSD drives (1.8”)

(2 per node)

4x Intel Xeon 7500Series CPUs(2 per node)

16x memory buffers

2x 30mm nodes

(8 per node)

HX5 ConfigurationsAdditional Features

Scale Connector

Slide 36

g2S, 16D, 8 I/O ports, 30m

4S, 32D, 16 I/O ports, 60mm

Internal USB for embedded hypervisorDual & redundant I/O and PowerIMM & UEFI

Page 37: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

MAX5 for HX5MAX5

HX5

6x memory buffersFireHawk

6 SMI lanes4 QPI ports3 scalability ports

Slide 37

24x VLP DDR3 memoryHX5+MAX5 Configurations2S, 40D, 8 I/O ports, 60m

3 scalability ports

Page 38: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Why IBM BladeCenter?

Open Architecture

Investment Protection

Flexibility & Choice

Open Networking

Total Cost Implications

Slide 38

Page 39: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Flexible and open I/O from an ecosystem of partners

Standard Speed Switches High Speed Switches

of partners

Standard SpeedIO Expansion Card

High SpeedIO Expansion Card

Ethernet – Fibre Channel – InfiniBand – FCoE – SAS – iSCSI – Virtual Fabric

Slide 39

Page 40: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Cisco Nexus 400ISwitch Features:

14 ports provide 10Gb to each blade6 uplinks at 10Gb - SFP+ basedLow LatencySeamlessly integrates with Nexus family of productsManagement via CiscoWorks orManagement via CiscoWorks or DCNM

Investment Protection: 1Gb and 10Gb auto-negotiation1Gb and 10Gb auto negotiationWorks with both 1Gb and 10Gb adapters on the serverConnects to 1Gb or 10Gb ports using ith SFP SFP d l i theither SFP or SFP+ modules in the

uplinks ports Future Proof:

Optional upgrade to IO Convergence

Slide 40

Optional upgrade to IO Convergence through a license key

Page 41: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Cisco Nexus FamilyCisco Nexus FamilyComplete data center class switching portfolioConsistent data center operating system across all platformsp g y pInfrastructure scalability, transport flexibility and operational manageability

Nexus 7000(M d l S it h

Nexus 2000Nexus 5000

(Modular Switch Platform)

Nexus 1000V(Virtual Switch) Nexus 4000

(Blade Switch)

1K1KCisco Nexus 1000V

2008

x86

(Fabric Extender)

Nexus 5000(Fixed Config

Switch)

(Blade Switch)

NX-OS Data Center Operating System

Slide 41

Data Center Network Manager

Page 42: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Converged NetworkingC Fibre Uplink to StorageCisco 5010 Switch

Cisco 4001i 10Gb Twinax Uplink to 5010

SwitchUplink to 5010

Slide 42

Advanced Management Modules

Page 43: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

BNT Virtual Fabric 10Gb SwitchFIRST FCoE Ready Switch for blades!

BNT Virtual Fabric 10Gb Switch

14 down & 10-ports of Uplink bandwidth at less $500 per portp p $ p pConsumes 75W of power – less than a regular light bulb!Investment Protected:

Can connect to 1Gb or 10Gb datacenter infrastructure (1G or 10G (uplinks)Can support 1Gb or 10Gb adaptersCan support convergence network traffic (via future firmware upgrade)upgrade)

Throughput performance no longer an issueUp to 40 ports (10Gb each) per BladeCenter H chassisUp to 40Gb per blade serverp p

Simplified Management over 10GbSerial over LAN & cKVM support

Slide 43

Page 44: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

VMready with BNTVirtual Machine Aware Networking: VMready

Measure and manage VM trafficAssign network parameters per Virtual MachineConsistent network settings during VM migrationsSwitch Resident code – nothing to change on the g gserverWorks with all hypervisorsShipping in production since Feb 2009Shipping in production since Feb 2009• BLADE OS 6.1 provides 2nd gen VMready with VMware

integration

Slide 44 44

Page 45: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

New Brocade Converged Solution

Brocade Converged 10GbE Switch Module

Brocade 2-port 10GbE Converged Network Adapter

The First integrated Converged Switch with Enet and FC Ports in same package

Multi-protocol support (10GbE, CEE, FCoE, FC and SW iSCSI) for maximum IO flexibility

Dynamic Ports on Demand (DPOD) provides scalability so you buy only what you needDynamic Ports on Demand (DPOD) provides scalability so you buy only what you need

More ports, more bandwidth, and greater flexibility than HP’s FlexFabric or Cisco UCS

Slide 45

Page 46: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

IBM BladeCenter Open FabricIBM BladeCenter Open FabricAn integrated server I/O portfolio providing a comprehensive

set of interconnects and smart management tools

Supported interconnects: Management Software:EthernetFibre ChannelSerial Attached SCSI (SAS)

BladeCenter Open Fabric ManagerIBM Systems Director

Serial Attached SCSI (SAS)iSCSIInfiniBand

Tivoli® Intelligent OrchestratorBNT SmartConnect

Slide 46

Supported across virtually ALL chassis, blades and switches

Page 47: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

What’s the problem?

LANLUN

MAC MAC WWN WWNMAC MAC WWN WWN

X X X X

Slide 47

Page 48: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Blade Deployment Made Easy

BOFM B i Ad d M t M d l b d Fi O ti

What is Open Fabric Manager?

BOFM Basic: Advanced Management Module based Firmware OptionI/O address assignment for initial blade deployment and re-deployment

Slot-based I/O address assignment – Enet MAC, FC WWNs, SAS WWNs, FC boot

targets and SAS boot targets

Pre-assignment allows LAN/SAN configuration prior to blade installation

Automatic re-assignment on blade swap (aka blade rip/replace)

Slide 4848

Page 49: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Open Fabric Manager BladeCenter

WW

N

1W

WN

2

WW

N

3

WW

N

4ManagementModuleManagementModule Boot

Blade 1 Blade 1

Switc

h

Boot

LUN

Blade 2 Blade 2

rpris

e SA

N S

.

Boot

LUN

Ente

r

. .

. . .

Blade 14 Blade 14

Slide 49

Fibre Channel World Wide Namesare assigned to blade slot by AMM

QLogic, Cisco, Brocade Switch Module

Page 50: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Open Fabric Manager - BasicBladeCenter

WW

N

3

WW

N

4ManagementModuleManagementModule Boot

Blade 1 Blade 1 WW

N

1W

WN

2

Switc

h

Boot

LUN

Blade 2 Blade 2

rpris

e SA

N S

.

SpareBlade SpareBlade

Boot

LUN

WW

N

3W

WN

4

Ente

r

. .

. . .

Blade 14 Blade 14

Slide 50

Fibre Channel World Wide Namesare assigned to blade slot by AMM

QLogic, Cisco, Brocade Switch Module

Page 51: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Blade Deployment Made Easy

BOFM B i Ad d M t M d l b d Fi O ti

What is Open Fabric Manager?

BOFM Basic: Advanced Management Module based Firmware OptionI/O address assignment for initial blade deployment and re-deployment

Slot-based I/O address assignment – Enet MAC, FC WWNs, SAS WWNs, FC boot

targets and SAS boot targets

Pre-assignment allows LAN/SAN configuration prior to blade installation

Automatic re-assignment on blade swap (aka blade rip/replace)

BOFM Advanced Upgrade: Standalone Utility or IBM SystemsDirector ExtExt

I/O Address assignment plus policy based automation

Creates standby blade pools – Event Action Plans

Provides I/O parameter and VLAN migration

Slide 5151

Provides I/O parameter and VLAN migration

to standby blades in case of blade failure

Page 52: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Open Fabric Manager - AdvancedBladeCenter

WW

N

1

WW

N

2ManagementModuleManagementModule Boot

Blade 1 Blade 1

Switc

h

Boot

LUNWW

N

1W

WN

2

Blade 2 Blade 2

rpris

e SA

N S

.

WW

N

3W

WN

4

Boot

LUN

Ente

r

. .

SpareSpare

. . .

Blade 14 Blade 14 SpareBlade SpareBlade

Slide 52

Fibre Channel World Wide Namesare assigned to blade slot by AMM

QLogic, Cisco, Brocade Switch Module

Page 53: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Advanced Open Fabric Manager Failover Scenarios

Example 1: Intra-Chassis FailoverExample 3: Inter and Intra-Chassis Failover

Scenarios

Fully Automated F ilFailoverSupports up to 100 chassis

Multiple Blade Source Pool with Single Standby Pool

chassisManage up 1400 blade fail-over poolpDirector Extension or Stand-alone

fi ticonfigurationsNetwork and storage switch independent

Slide 53

Multiple Blade Source Pool with Multiple Blade Standby Pool

Example 2: Multi-Blade Standby Pool

Cross Chassis Source and Standby Blade Pools

switch independent

Page 54: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Dynamic Infrastructure with System x & BladeCenter“Fit for Purpose”Fit for Purpose

Enterprise &

Server Consolidation, Virtualization

iDataPlex

p

BladeCenter

Infrastructure Simplification

Virtualization

Web 2.0, HPC

Scale Out

Scal

eU

p Simplification, Application

Serving

HPC, Grid, Energy

Efficiency

Scale Out

Stand alone Applications

Slide 54

Rack and Tower

Page 55: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Ci d H i k

IBM Power System Server Update

Cindy HenricksPower Systems Specialist

Page 56: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Power 7 Systems Portfolio

Power 780Power 795

Power 770

Power 750

Power 755Power 700

Power 755

HPCHPC

701 & 702Power 710

Power 720Power 730

Slide 5656

Power 740

Page 57: State of Georgia S&St CttServer & Storage Contractpur.doas.ga.gov/TGM/SWC_Contracts/SWC90813_02_Presentation.pdf · Istanbul 45nm Magny-Cours (6xxx) 45nm 8-12- Core Slide 5 Quad Core

Processor Technology Roadmap

POWER8

POWER6POWER7

45 nm

POWER4

POWER5130 nm

65 nm

Dual Core Chip Multi Processing

Dual CoreEnhanced ScalingSMTDi t ib t d S it h

Dual CoreHigh Frequencies Virtualization +Memory Subsystem +

Multi CoreOn-Chip eDRAM Power Optimized CoresM S b t

180 nm

Chip Multi ProcessingDistributed SwitchShared L2Dynamic LPARs (32)

Distributed Switch +Core Parallelism +FP Performance +Memory bandwidth +Virtualization

Memory Subsystem +Altivec Instruction RetryDyn Energy MgmtSMT +Protection Keys

Mem Subsystem ++SMT++Reliability +VSM & VSX (AltiVec)Protection Keys+

Concept Phase

Slide 57

2001 2004 2007 2010


Recommended