Kathryn Vandiver, vSAN ReadyLabs Engineering, VMware Vivek Sarathy, Non-Volatile Memory (NVM) Solutions Group, Intel STO1053BES #VMworld2017 #STO1053BES Redefine vSAN Deployments with Next Generation Intel® Xeon® processor, Intel® Optane™ and Intel® 3D NAND SSDs VMworld 2017 Content: Not for publication or distribution
Transcript
Page 1: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Kathryn Vandiver, vSAN ReadyLabs Engineering, VMwareVivek Sarathy, Non-Volatile Memory (NVM) Solutions Group, Intel

STO1053BES

#VMworld2017 #STO1053BES

Redefine vSAN Deployments with Next Generation Intel® Xeon® processor, Intel® Optane™ and Intel® 3D NAND SSDs

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 2: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

• This presentation may contain product features that are currently under development.

• This overview of new technology represents no commitment from VMware to deliver these features in any generally available product.

• Features are subject to change, and must not be included in contracts, purchase orders, or sales agreements of any kind.

• Technical feasibility and market demand will affect final delivery.

• Pricing and packaging for any new technologies or features discussed or presented have not been determined.

Disclaimer

#STO1053BES CONFIDENTIAL 2

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 3: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

3

Legal Notices and Disclaimers

Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software or service activation. Learn

more at intel.com, or from the OEM or retailer.

No computer system can be absolutely secure.

Tests document performance of components on a particular test, in specific systems. Differences in hardware, software, or configuration will affect

actual performance. Consult other sources of information to evaluate performance as you consider your purchase. For more complete information

about performance and benchmark results, visit http://www.intel.com/performance.

Cost reduction scenarios described are intended as examples of how a given Intel-based product, in the specified circumstances and

configurations, may affect future costs and provide cost savings. Circumstances will vary. Intel does not guarantee any costs or cost reduction.

This document contains information on products, services and/or processes in development. All information provided here is subject to change

without notice. Contact your Intel representative to obtain the latest forecast, schedule, specifications and roadmaps.

No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document.

Intel does not control or audit third-party benchmark data or the web sites referenced in this document. You should visit the referenced web site

and confirm whether referenced data are accurate.

Intel, the Intel logo, Xeon, Intel® Optane™, and 3D XPoint are trademarks of Intel Corporation in the U.S. and/or other countries.

*Other names and brands may be claimed as the property of others.

© 2017 Intel Corporation.

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 4: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Agenda

1 Business Overview

2 Emerging Technology and Trends

3 vSAN All Flash – Overview and Customer Adoption

4 vSAN on Next Gen Platform – Intel® Optane™ Technology

5 Manageability Improvements for Next Gen Intel based Platform

6 Summary

4#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 5: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Market Segmentation for Hardware

5

1. General Purpose

Rack Servers - General purpose workloads

BCA, Database, VDI, ROBO, DR, Test/Dev

2. Storage Dense

Rack Servers - Storage Heavy workloads

Archiving, video streaming, analytics

3. Compute Intensive

Blade Servers - Compute Heavy workloads

Web apps, HPC, real time analytics, In-memory DB

4. ComposableInfrastructure

Scaling storage & compute independently for disaggregated workloads

Data warehouses, Search engines databases, Log aggregation

vSAN for various customer workloads#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 6: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

vSAN Ready Node: Many Platform Choices to Maximize Flexibility

Many Platform Choices15 server vendors

164 platform choices

Flexible SupportIndividual vendor support

Single support from partner

Software FlexibilityBring your own software

Factory install software

Licensing OptionsBring your own license

Purchase license with platform

https://www.vmware.com/resources/compatibility/search.php?deviceCategory=vsan#STO1053BES CONFIDENTIAL 6

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 7: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

vSAN Hardware Enhancements in 2016 & 2017

7

Overview

➢ Enable high density vSAN ReadyNode™ with support for 512e

Drives – vSAN 6.5

➢ Certified Intel® Optane™ SSD as caching tier for vSAN

➢ LED Management for controllers & NVMe

➢ Revised caching guidelines for usage of larger capacity cache

drives in Q1, 2017

➢ Hardware Lifecycle Management: Automated controller

driver/firmware updates for major OEMs in Q1, 2017

Benefits

➢ Larger capacity on high density server configs supported only in

512e/4Kn format

➢ Better All Flash TCO* with improved caching guidelines

➢ Simplified and automated HW life cycle management

* https://vsansizer.vmware.com/vsansizing/html/dcScaleDeploymentsOptions.html#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 8: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Technology Trends

CPU densities

continues to

increase

Hi-Density Flash and

NVMe will dominate

Enterprise Storage

High speed

interconnect to keep

up with fast storage

Impact of Key Technology Trends on vSAN

• All Flash Market is growing at a rapid rate – 38% CAGR over last 5 years

• Enterprise customers are adopting slowly moving away from using magnetic drives

• Newer high speed storage & network interconnects are disrupting the HCI market.

• Leverage hardware trends to deliver All Flash vSAN at the best $/IOP & $/Gig

#STO1053BES CONFIDENTIAL 8

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 9: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Intel® Xeon® Scalable Processors optimized for Storage

Platform

Performance

Server

Agility

Efficiency

at Scale

Platform to drive storage transformation

Intel Xeon

Processor

Intel Xeon

Processor

UPI

DDR4 DDR4

X16 PCIe

VMD VMD

ISA-LSPDKVROC

Memory Drive

Integrated Networking

RDMA

#STO1053BES CONFIDENTIAL 9

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 10: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Cost Delay MORELESSHIGHERLOWER

Intel Technology Innovations Fill the Memory and Storage Gap

Intel® Optane™

Technology

Higher

performance

Intel 3D NANDTechnology

Lower cost & higher

density

#STO1053BES CONFIDENTIAL 10

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 11: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Caching

DataPersistencevSAN

vSAN All Flash Today

11

• 2 Tier Architecture:

• Tier 1 Caching: High performance,

high endurance flash for caching

writes

• Tier 2 Data Persistence: Read

intensive, low endurance drives for

capacity

• Customer Adoption: Gaining significant

momentum, aligned with enterprise

adoption of flash, particularly NVMe

NVMeSSD NVDIMM

Capacity TierFlash Devices

Reads primarily from capacity tier

Writes cached first,Reads from capacity tier

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 12: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

NVMe Use Cases for vSAN All Flash

High Performance Caching & Capacity Device

NVMe Configurations for vSAN

✓ NVMe as Caching Tier for vSAN (2-4 NVMe as caching tier per server)

✓ NVMe as Capacity Tier for vSAN (7 NVMe capacity tier per cache device)

✓ ALL NVMe (caching & capacity) platforms (with PCIe switches, up to 24 drives per server)

Advantages:

✓ General trend of customers moving toward NVMe – better TCO*, more power efficiency, compact form factors and better error handling

✓ Good for Latency sensitive workloads such as OLTP/SQL, VDI – Full Clones

✓ Good for write intensive workloads requiring high IOPS – analytics, database, media streaming as an example

NVMe/PCIe

* https://estimator.intel.com/sddc12#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 13: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Based on Telemetry Data &Customer Surveys

Customer Adoption of vSAN All Flash

• 84% of customers are expected to adopt Purley within the next year

• Higher adoption of OEM’s who are offering all NVMe ReadyNodes

• Increase in VCG Listings and ReadyNodes with All Flash over Hybrid

Today: 65%

#STO1053BES CONFIDENTIAL 13

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 14: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Use Case

• vSAN All-Flash supporting over 1200+ stores

• Tier-1 Apps including store inventory management, customer portals, credit card

transaction processing, customer loyalty systems

• BCA like Microsoft SQL Server, Exchange, SharePoint

• 1.2 PB, 4000 VMs

• Supermarket chain across Denmark and Europe

• 1200+ stores

COOP

Challenges

• Competitive retail industry meant constant changes, IT need to respond fast

• Traditional storage, networking, maintenance very costly with limited staff

Benefits

• Standardization: Single, integrated VMware stack with full flexibility to grow

• Best TCO Compared to Any Other Vendor: best price/performance ratio

compared to storage vendors and Azure Cloud

• Performance Exceeding Expectations: Latency-sensitive business-critical

applications far exceeded performance goals

#STO1053BES CONFIDENTIAL 14

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 15: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Use Case

• Tier-1 OLTP applications like mission-critical billing and reservation systems on SQL

• 800TB – 1PB with 48 nodes across 4 clusters

• All-Flash for latency sensitive workloads

• Plans to move entire Tier-1 Apps to vSAN

• Apps are low compute/high capacity

“For airline apps, more important than IOPS

is reliably low latency, which we could

achieve with vSAN All-Flash”- Philipp Schwarzhuber, Director of SDDC

Hardware Platform

• Dell R730XD servers

Largest Airline in EuropeTier-1 Applications on vSAN

Challenges

• Standardization: SDDC initiative to standardize on Dell

• Meet demanding performance needs of billing and reservation systems

• Need cost savings and ease of scale with increasing application usage

Benefits

• Convergence of teams: team is less siloed, more productive and builds new skillsets

• OPEX improvement: Day-to-day operations are lean and efficient

• Easy to scale: grow with unpredictable airline business

#STO1053BES CONFIDENTIAL 15

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 16: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Use Case

• SDDC Initiative to go 100% HCI with All-Flash

• 48 Node Cluster managing 500TB capacity

• All-Flash for latency sensitive Financial Apps running DB2

• Leading global financial services firm

• Providing Investment banking, securities,

wealth management, and services

Leading Global Financial Services Firm

Challenges

• Standardization: SDDC initiative to standardize on All Flash

• Financial Apps (business critical) & Desktop Virtualization

• Tier 1 workloads requiring high performance / low latency for DB2 and VDI

Benefits

• VSAN All Flash delivers highest performance on NVMe at the lowest price

• Ease of management

• Scalable All Flash VDI solution for Full Clones

Large Financial Institute

#STO1053BES CONFIDENTIAL 16

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 17: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Intel® Optane™ and Intel® 3D NAND SSDs for vSAN

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 18: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

18

5-8x faster at low Queue

Depths1

Vast majority of applications

generate low QD storage

workloads

1. Common Configuration - Intel 2U Server System, OS CentOS 7.2, kernel 3.10.0-327.el7.x86_64, CPU 2 x Intel® Xeon® E5-2699 v4 @ 2.20GHz (22 cores), RAM 396GB DDR @ 2133MHz. Configuration – Intel®

Optane™ SSD DC P4800X 375GB and Intel® SSD DC P3700 1600GB. Performance – measured under 4K 70-30 workload at QD1-16 using fio-2.15.

Intel® Optane™ Breakthrough Performance

Tests document performance of components on a particular test, in specific systems. Differences in hardware, software, or configuration will affect actual performance.

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 19: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Intel® Optane™ Storage Performance Characterization

Higher is better

Low

er

is b

etter

10x latency reduction

▪ < 10usec latency †

100x QoS improvement

▪ < 200usec 99.999th r/w †

Latency vs. Load: NAND SSD vs. Intel® Optane™ SSD (Intel® SSD DC P3700 vs. Intel® Optane™ SSD DC P4800X)

† vs. NAND based SSD

QD

~12

19#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 20: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Intel® 3D NAND SSDs. Optimized for Capacity and Cost

Arr

ay

Smaller FG cell

Architectural efficiency (CMOS under array)

Scale to bigger capacities

Manufacturing efficiency

More

GBper wafer

Advantages

up to

20%higher areal density1

#STO1053BES CONFIDENTIAL 20

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 21: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

21

Intel® 3D NAND SSDs. Optimized for Power-Efficient Capacity

48U Open Rack with 12 kw Budget

Compute and Networking

50%of rack space*

50%of rack space*

U.2 15mm 2 TB at 25 W 720 TB, 9 kW

25%of power budget*

75%of power budget*

U.2 7mm 4 TB Intel SSD DC P4501 Series at 10W, 1.44

PB, 3.6 kW

OR

25%of power budget*

30%of power budget*

45%of power budget

SAVED! *

Sources – Intel and Facebook. Facebook Lightening JBOF: https://code.facebook.com/posts/989638804458007/introducing-lightning-a-flexible-nvme-jbof/. Intel – Specifications for Intel® SSD DC P3520 and Intel® SSD

DC P4501. Each rack populates 24U with 15 4TB drives in each rack unit. Storage on the P3520 48U rack consumes 9kW (24U x 15 SSDs/U x 25W/drive max power of U.2 form factor for power budget) while the P4501

rack consumes 3.6kW (24U x 15 SSDs/U x 10W/drive).

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 22: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

22

vSphere vSAN

vSAN Datastore

NVMe NVMe

Cache

Capacity

All Writes are served by the Cache Tier

– Absorbs the bulk of the write rate from the application

– Data is de-staged or drained from Write Cache to

Capacity Tier only when needed, extending the life of

the capacity tier

– Deduplication / compression occurs in the de-staging

process

Reads are served directly from the Capacity Tier

• Read performance from capacity flash is more than

sufficient.

Intel® Optane™ SSD provides benefit for low latency

and high performing transactional workloads

Caching and Persistent Tiers with All Flash

SSD SSD

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 23: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Evaluator Group Study with Intel® Optane™ SSD and Intel® Xeon® Scalable Processor

▪ Real-world application profiles

Tests utilized “Application Workloads”

▪ IOmark-VM = General Database and Server VM

▪ HammerDB TPC-C = High Performance Database

Two Different Application Workload Profiles

#STO1053BES CONFIDENTIAL 23

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 24: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Up to 10x Performance w/ Latest HCI Technology on vSAN

24

80

288

480

800 800

1120

0

200

400

600

800

1000

1200

IOmark-VM’s

SSD + HDD

NVMe + SSD

All-NVMe

Optane + S3520

Optane + P4500

Optane + P4500( No Dedupe)

IOmark-VM Performance: 4-Node HC

Optane + NVMe1st Gen NVMeHybrid HCI

Hybrid HCI

1st Gen NVME

Optane + NVMe

https://www.evaluatorgroup.com/document/intel-next-generation-technology-powering-new-performance-levels/#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 25: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Up to 9x Better Price/Performance with Latest HCI Technology on vSAN

25

$2,048

$675 $545

$293 $302 $237

$0

$500

$1,000

$1,500

$2,000

$2,500

$ / IOmark-VM-HC

SSD + HDD

NVMe + SSD

All-NVMe

Optane + S3520

Optane + P4500

Optane + P4500( No Dedupe)

Price / Performance: 4-Node HC

Optane NVMe1st Gen NVMeHybrid HCI

Hybrid HCI

1st Gen NVMe

Optane NVMe

https://www.evaluatorgroup.com/document/intel-next-generation-technology-powering-new-performance-levels/

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 26: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

vSAN Database Results (Running a TPC-C “like” workload)

• Nearly 2X better performance and 2X lower price / performance

– 89% higher TPM Performance

– 44% lower cost per TPM

26

$0.05

4,828,595

9,116,024

-

1,000,000

2,000,000

3,000,000

4,000,000

5,000,000

6,000,000

7,000,000

8,000,000

9,000,000

10,000,000

Total TPM

Total TPM for 4-Node vSAN

P4600+P4500

Optane+P4500

$0.03

$-

$0.01

$0.01

$0.02

$0.02

$0.03

$0.03

$0.04

$0.04

$0.05

$0.05

$ / TPM HC

$ / TPM 4-Node vSAN

P4600+P4500

Optane+P4500

https://www.evaluatorgroup.com/document/intel-next-generation-technology-powering-new-performance-levels/

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 27: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

HCIBench Tests:Up to 3x lower latency with Latest HCI Technology

*Other names and brands names may be claimed as the property of others

27

System Configuration: 4 Node vSAN* Cluster. Per Node configuration: A:Supermicro* SuperServer 2028U-TN24R4T+ Dual Intel® Xeon® E5-2687Wv4 (12 Core @ 3.0 Ghz), B. Supermicro* SuperServer 2029U-TN24R4T+ Dual Intel® Xeon® scalebale processor, Supermicro* Server Board, 256 GB DDR4 RAM, Boot Drive, 1x Intel® SSD DC S3710 Series (200 GB, 2.5”), vSAN Cluster: Virtual SAN SSDs - 2 Disk Groups comprised of 2x Intel® SSD DC P4800x Series (375GB, 2.5” SFF), 8x Intel® SSD DC P4500 Series (4 TB, 2.5” SFF), vSAN Cluster: Virtual SAN SSDs - 2 Disk Groups comprised of 2x Intel® SSD DC P3700 Series (400GB, 2.5” SFF), 8x Intel® SSD DC P3520 Series (2 TB, 2.5” SFF),

Server: Supermicro* 2028U-TN24R4T with

2 x Intel® Xeon® E5

:

Cache Tier:

2x Intel® SSD DC P3700 @ 400 GB

Transition

to

New Intel® Technology

based vSAN

2xup to

Increase Storage

Efficiency

Capacity Tier:

8x Intel® SSD DC P3520 @ 2TB

Server: Supermicro 2029U-TN24R4T with

2 x Intel® Xeon® Scalable Processor

Cache Tier:

2x Intel® SSD DC P4800x @ 375 GB

Capacity Tier:

8x Intel® SSD DC P4500 @ 4TB

3xup to

Lower

Latency

A B

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 28: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Manageability Improvements for Next Gen Intel® based platform

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 29: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

29

Storage at Scale Requires Efficiency

Simple, Reliable and

Manageable

IT Efficiency starts with reliable and serviceable solutions

Storage inspired Intel® Xeon® Platforms enable efficiency to

manage data at scale

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 30: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

30

Efficiency Challenge: Lack of Reliability & Serviceability

Did your vSAN node PSOD due to surprise PCIe* SSD removal?

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 31: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

31

Which SSD Needs Replacement? Whoops!

These tiny LEDs

are critical

important.

Efficiency Challenge: Lack of Reliability & Serviceability

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 32: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Intel® Volume Management Device

PCIeRoot Complex

Operating System Operating System

Intel® Xeon® E5v4 Processor

Intel® Xeon® Scalable

ProcessorPCIe Root Complex

Intel® VMD

PCIeSSDs

PCIeSSDs

After Intel® VMDBefore Intel® VMD

32

– Intel® VMD is a new technology to enhance solutions with PCIe* storage

– Benefit for VMware* vSAN

– Intel® VMD enables:

• Isolating fault domains for device surprise hot-plug and error handling

• Provide consistent framework for managing LEDs

• Simplify PCIe storage software stacks

Intel® VMD enables customers to simplify and harden solutions using PCIe storage.

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 33: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

vSAN NVMe SSDs Hot Plug and LED Management

33

Without Intel® VMD

Supported in vSAN:

• Hot Insert: Supported if the server platform

supports PCIe Hot Plug

• Prepared Hot Removal: Needs user

management operations to hot remove

NVMe SSDs

Not Supported in vSAN:

• Surprise Hot Plug Removal

• Surprise Hot Insert

• LED Management for NVMe SSDs

With Intel® VMD

Benefit to vSAN:

• Surprise Hot Plug Removal ✓

• Surprise Hot Insert ✓

• LED Management for NVMe SSDs ✓

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 34: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Intel® NVMe SSDs Firmware Auto Update

34

vSphere vSAN

vSAN DatastoreNVMe NVMe ….. NVMe…..

Intel® SSD Data Center Tool

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 35: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

#STO1053BES CONFIDENTIAL 35

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 36: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

What’s next with Intel® NVMe SSDs and vSAN?

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 37: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

37

“Ruler” form factor for Intel® SSDs.

Designed from the ground up to optimize rack efficiency, the new Ruler

Form Factor delivers unparalleled Space-Efficient Capacity,

Operationally- Efficient Design and Scalable Manageability.

“Ruler” form factor for Intel® SSD DC P4500 available by end of 2017.

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 38: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

1PB IN 42u W/2 TB HDDs

Enabling up to 1PB of storage in a 1U server rack

Opening up new use cases in

datacenter storage with disruptive

total cost of ownership

Storage

Capacity

1PB in 1U Intel® 3D NAND SSD, 32TB

ruler in 2018

38#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 39: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

“Ruler” form factor for Intel® SSDs with vSAN - (Future)

“Ruler” form factor for

Intel® SSDs

NVMe Over Fabric

✓ Scale compute and storage independently (disaggregated)

✓ Expand storage (dynamically) to serve compute blades

Workloads for disaggregated storage

✓ Data warehouses, Search databases, Log aggregation, analytics

NVMeOF

EthernetFabric

PCIe

Switch

Compute

Blades

Next Gen

NVMe/PCIe

#STO1053BES CONFIDENTIAL 39

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 40: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

Summary:

40

Jointly committed to delivering vSAN HCI

solutions built on cutting-edge Intel® Flash

Technology

Intel® Optane™ and Intel ® Xeon™

Scalable Processors Delivers All Flash

vSAN at the best $/IOP, $/Gig and low

latency

Breakthrough performance for HCI

Higher responsiveness to meet today’s

modern workload needs

Intel ® Optane ™ SSD andIntel® SSD DC P4500

Intel ® Xeon ™ Scalable Platforms

https://www.evaluatorgroup.com/document/intel-next-generation-technology-powering-new-performance-levels/

#STO1053BES CONFIDENTIAL

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 41: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

VMworld 2017 Content: Not fo

r publication or distri

bution

Page 42: STO1053BES Redefine vSAN Deployments with Next · PDF fileTests document performance of components on a particular test, ... Scaling storage & compute ... adoption of flash, particularly

VMworld 2017 Content: Not fo

r publication or distri

bution


Recommended