9
ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›” 75 ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ -๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ ๊ฑฐ๋™ ์ด์„ฑํฌ 1 ๏ฝฅ ๊น€์˜ํ˜ธ 2 ๏ฝฅ ์ตœ์„ฑ๋ชจ 3 * 1 ๊ณตํ•™๋ฐ•์‚ฌ, ํŠนํ—ˆ์ฒญ, ์‚ฌ๋ฌด๊ธฐ๊ธฐ์‹ฌ์‚ฌ๊ณผ, 2 ๊ณตํ•™๋ฐ•์‚ฌ, ใˆœ์ง€์Šน์ปจ์„คํ„ดํŠธ, ๊ธฐ์ˆ ์—ฐ๊ตฌ์†Œ, 3 ๊ต์ˆ˜, ์„œ์šธ์‹œ๋ฆฝ๋Œ€ํ•™๊ต, ๊ฑด์ถ•ํ•™๋ถ€ Structural Behavior of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm Lee, Seong Hui 1 , Kim, Young Ho 2 , Choi, Sung Mo 3 * 1 Ph.D, Office Equipment Examination Division, Korean Intellectual Property Office, DaeJeon, 35208, Korea 2 Ph.D, Institute of R&D, Jiseung Consultant Co., Ltd., Seoul, 06128, Korea 3 Professor, Department of Architectural Engineering, University of Seoul, Seoul, 02504, Korea Abstract - Existing tubes for concrete filled tubular structure are made through welding of four plates irrespective, but the production performance is poor and special welding technique is needed to weld the internal or through diaphragm. Accordingly, We developed a welded built-up square steel tube having a welding lines and a stiffeners at location out of stress concentration. The welded built-up square steel tube occurred a interference with stiffeners at the internal or through diaphragm, therefore researches of a external diaphragm for welded built-up square CFT column connections are needed for the purpose of avoidance of a interfere with stiffeners. In this study we suggest a design formulation for external diaphragm of the welded built-up square CFT external diaphragm connections. Four specimens were manufactured for a experimental test, then we analyzed the behaviors of the specimens. Keywords - Concrete filled steel tube, Cold forming, Stiffener, Beam-to-column, Width-thickness ratio Note.-Discussion open until October 31, 2016. This manuscript for this paper was submitted for review and possible publication on November 11, 2015; revised December 14, 2015; approved on January 13 2016. Copyright โ“’ 2016 by Korean Society of Steel Construction * Corresponding author. Tel. +82-2-6490-2759 Fax. +82-2-6490-2749 E-mail. [email protected] 1. ์„œ ๋ก  ์ตœ๊ทผ ์ง€๊ฐ€์˜ ์ƒ์Šน์œผ๋กœ ๊ณ ์ธต๊ฑด๋ฌผ์ด ์ฆ๊ฐ€ํ•˜๊ณ  ์žˆ์œผ๋ฉฐ, ๊ณต๊ธฐ ๋‹จ์ถ•๊ณผ ์ตœ๋Œ€ํ•œ์˜ ์ž„๋Œ€๋ฉด์ ์„ ํ™•๋ณดํ•˜๊ธฐ ์œ„ํ•ด ๋‹ค์–‘ํ•œ ๊ฑด์ถ•๊ณต ๋ฒ•๋“ค์ด ์ ์šฉ๋˜์–ด ์™”๋‹ค. ๊ทธ ์ค‘ ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „๊ฐ•๊ด€(CFT) ๊ตฌ์กฐ ๋Š” ๊ฐ•๊ด€์ด ๋‚ด๋ถ€ ์ฝ˜ํฌ๋ฆฌํŠธ์— ๋Œ€ํ•œ ๊ฑฐํ‘ธ์ง‘ ์—ญํ• ์„ ํ•  ๋ฟ ์•„๋‹ˆ๋ผ ์ฝ˜ํฌ๋ฆฌํŠธ๊ฐ€ ๊ฒฝํ™”๋œ ํ›„์—๋Š” ๊ฐ•๊ด€์ด ๋‚ด๋ถ€ ์ฝ˜ํฌ๋ฆฌํŠธ์˜ ํŒฝ์ฐฝ์„ ๊ตฌ์†ํ•˜๊ณ  ์ฝ˜ํฌ๋ฆฌํŠธ๊ฐ€ ๊ฐ•๊ด€์˜ ๊ตญ๋ถ€์ขŒ๊ตด์„ ์ง€์—ฐ์‹œ์ผœ ๊ตฌ์กฐ๋‚ด๋ ฅ ์„ ์ƒ์Šน์‹œํ‚ค๋Š” ์‹œ๊ณต์„ฑ๊ณผ ๊ตฌ์กฐ์„ฑ๋Šฅ์ด ์šฐ์ˆ˜ํ•œ ๊ตฌ์กฐ๋กœ ์ธ์‹๋˜ ์–ด ๋งŽ์€ ๊ณ ์ธต๊ฑด๋ฌผ์— ์ ์šฉ๋˜์–ด ์™”๋‹ค [1],[2] . ์ฝ˜ํฌ๋ฆฌํŠธ์ถฉ์ „ ๊ฐ•๊ด€(CFT)๊ธฐ๋‘ฅ์— ์‚ฌ์šฉ๋˜๋Š” ๊ฐํ˜•๊ฐ•๊ด€์€ ๊ฐ• ํŒ 4๊ฐœ์˜ ๋ชจ์„œ๋ฆฌ๋ฅผ ์šฉ์ ‘ํ•˜์—ฌ ์ œ์ž‘ํ•˜๋Š” ๋ฐ•์Šคํ˜• ๊ธฐ๋‘ฅ์ด ์ผ๋ฐ˜ ์ ์ด๋‚˜ ๋‘๊บผ์šด ๊ฐ•ํŒ์œผ๋กœ ์ œ์ž‘๋˜๋Š” ๊ฐ•๊ด€์€ ์ œ์ž‘ํšจ์œจ์ด ๋–จ์–ด ์งˆ ๋ฟ ์•„๋‹ˆ๋ผ ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜ ์ œ์ž‘ ์‹œ์—๋„ ํŠน๋ณ„ํ•œ ์šฉ์ ‘๊ธฐ ์ˆ ์ด ํ•„์š”ํ•˜์—ฌ ์ตœ๊ทผ ์–‡์€ ๊ฐ•ํŒ์„ ์ด์šฉํ•œ ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „๊ฐ•๊ด€ ๊ธฐ๋‘ฅ์„ ๊ฐœ๋ฐœํ•˜๊ธฐ ์œ„ํ•œ ์—ฐ๊ตฌ๊ฐ€ ์ˆ˜ํ–‰๋˜์–ด ์™”๋‹ค [3],[4],[5],[6],[7] . ๊ตญ ๋‚ด์—์„œ๋Š” ์ด์„ฑํฌ [8],[9],[10] ๊ฐ€ ์–‡์€ ๊ฐ•ํŒ์„ ์ ˆ๊ณกํ•œ ใ„ฑ์ž ํ˜•์ƒ์˜ ๋‹จ์œ„๋ถ€์žฌ๋ฅผ ์„œ๋กœ ์šฉ์ ‘ํ•˜๋˜ ๊ตญ๋ถ€์ขŒ๊ตด์„ ์ง€์—ฐ์‹œํ‚ค๋Š” ์œ„์น˜์— ์Šคํ‹ฐํ”„๋„ˆ๊ฐ€ ์œ„์น˜๋˜๋„๋ก ํ•œ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€์„ ๊ฐœ๋ฐœํ•˜๊ณ  ๊ตฌ์กฐ๊ฑฐ๋™์„ ํ‰๊ฐ€ํ•˜์˜€์œผ๋ฉฐ, ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€ ๊ธฐ๋‘ฅ-๋ณด ์ ‘ ํ•ฉ๋ถ€์˜ ํ˜•์‹์œผ๋กœ ์™ธ๋‹ค์ด์•„ํ”„๋žจ์„ ์ œ์•ˆํ•˜๊ณ  ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜ ์ธ์žฅ๋ ฅ์„ ๋ฐ›๋Š” ๋ถ€๋ถ„์„ ์ด์ƒํ™”ํ•œ ๋‹จ ์ˆœ์ธ์žฅ ์ ‘ํ•ฉ๋ถ€๋ฅผ ์ œ์ž‘ํ•˜์—ฌ ๊ตฌ์กฐ์‹คํ—˜์„ ์ˆ˜ํ–‰ํ•˜์˜€๋‹ค. ๊ทธ๋Ÿฌ๋‚˜ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ๊ฑฐ๋™์„ ๋ช…ํ™•ํžˆ ํŒŒ ์•…ํ•˜๊ธฐ ์œ„ํ•ด์„œ๋Š” ์‹ค๋Œ€ํ˜• ์‹คํ—˜์„ ์ˆ˜ํ–‰ํ•  ํ•„์š”๊ฐ€ ์žˆ์œผ๋ฉฐ, ๋ณธ ์—ฐ๊ตฌ์—์„œ๋Š” ์‹ค๋Œ€ํ˜• ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„ ๋žจ ์ ‘ํ•ฉ๋ถ€ ์‹คํ—˜์ฒด 4๊ฐœ๋ฅผ ์ œ์ž‘ํ•˜์—ฌ ๊ตฌ์กฐ์‹คํ—˜์„ ์ˆ˜ํ–‰ํ•˜๊ณ  ๊ตฌ Journal of Korean Society of Steel Construction Vol.28, No.2, pp.75-83, April, 2016 ISSN(print) 1226-363X ISSN(online) 2287-4054 DOI http://dx.doi.org/10.7781/kjoss.2016.28.2.075
Transcript
Page 1: Structural Behavior of Welded Built-up Square CFT Column ...

ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›” 75

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ ๊ฑฐ๋™

์ด์„ฑํฌ1๏ฝฅ๊น€์˜ํ˜ธ

2๏ฝฅ์ตœ์„ฑ๋ชจ

3*

1๊ณตํ•™๋ฐ•์‚ฌ, ํŠนํ—ˆ์ฒญ, ์‚ฌ๋ฌด๊ธฐ๊ธฐ์‹ฌ์‚ฌ๊ณผ,

2๊ณตํ•™๋ฐ•์‚ฌ, ใˆœ์ง€์Šน์ปจ์„คํ„ดํŠธ, ๊ธฐ์ˆ ์—ฐ๊ตฌ์†Œ,

3๊ต์ˆ˜, ์„œ์šธ์‹œ๋ฆฝ๋Œ€ํ•™๊ต, ๊ฑด์ถ•ํ•™๋ถ€

Structural Behavior of Welded Built-up Square CFT Column to Beam

Connections with External Diaphragm

Lee, Seong Hui1, Kim, Young Ho

2, Choi, Sung Mo

3*

1Ph.D, Office Equipment Examination Division, Korean Intellectual Property Office, DaeJeon, 35208, Korea

2Ph.D, Institute of R&D, Jiseung Consultant Co., Ltd., Seoul, 06128, Korea

3Professor, Department of Architectural Engineering, University of Seoul, Seoul, 02504, Korea

Abstract - Existing tubes for concrete filled tubular structure are made through welding of four plates irrespective, but the

production performance is poor and special welding technique is needed to weld the internal or through diaphragm. Accordingly,

We developed a welded built-up square steel tube having a welding lines and a stiffeners at location out of stress concentration.

The welded built-up square steel tube occurred a interference with stiffeners at the internal or through diaphragm, therefore

researches of a external diaphragm for welded built-up square CFT column connections are needed for the purpose of avoidance

of a interfere with stiffeners. In this study we suggest a design formulation for external diaphragm of the welded built-up square

CFT external diaphragm connections. Four specimens were manufactured for a experimental test, then we analyzed the

behaviors of the specimens.

Keywords - Concrete filled steel tube, Cold forming, Stiffener, Beam-to-column, Width-thickness ratio

Note.-Discussion open until October 31, 2016. This manuscript

for this paper was submitted for review and possible publication

on November 11, 2015; revised December 14, 2015; approved

on January 13 2016.

Copyright โ“’ 2016 by Korean Society of Steel Construction*

Corresponding author.

Tel. +82-2-6490-2759 Fax. +82-2-6490-2749

E-mail. [email protected]

1. ์„œ ๋ก 

์ตœ๊ทผ ์ง€๊ฐ€์˜ ์ƒ์Šน์œผ๋กœ ๊ณ ์ธต๊ฑด๋ฌผ์ด ์ฆ๊ฐ€ํ•˜๊ณ  ์žˆ์œผ๋ฉฐ, ๊ณต๊ธฐ

๋‹จ์ถ•๊ณผ ์ตœ๋Œ€ํ•œ์˜ ์ž„๋Œ€๋ฉด์ ์„ ํ™•๋ณดํ•˜๊ธฐ ์œ„ํ•ด ๋‹ค์–‘ํ•œ ๊ฑด์ถ•๊ณต

๋ฒ•๋“ค์ด ์ ์šฉ๋˜์–ด ์™”๋‹ค. ๊ทธ ์ค‘ ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „๊ฐ•๊ด€(CFT) ๊ตฌ์กฐ

๋Š” ๊ฐ•๊ด€์ด ๋‚ด๋ถ€ ์ฝ˜ํฌ๋ฆฌํŠธ์— ๋Œ€ํ•œ ๊ฑฐํ‘ธ์ง‘ ์—ญํ• ์„ ํ•  ๋ฟ ์•„๋‹ˆ๋ผ

์ฝ˜ํฌ๋ฆฌํŠธ๊ฐ€ ๊ฒฝํ™”๋œ ํ›„์—๋Š” ๊ฐ•๊ด€์ด ๋‚ด๋ถ€ ์ฝ˜ํฌ๋ฆฌํŠธ์˜ ํŒฝ์ฐฝ์„

๊ตฌ์†ํ•˜๊ณ  ์ฝ˜ํฌ๋ฆฌํŠธ๊ฐ€ ๊ฐ•๊ด€์˜ ๊ตญ๋ถ€์ขŒ๊ตด์„ ์ง€์—ฐ์‹œ์ผœ ๊ตฌ์กฐ๋‚ด๋ ฅ

์„ ์ƒ์Šน์‹œํ‚ค๋Š” ์‹œ๊ณต์„ฑ๊ณผ ๊ตฌ์กฐ์„ฑ๋Šฅ์ด ์šฐ์ˆ˜ํ•œ ๊ตฌ์กฐ๋กœ ์ธ์‹๋˜

์–ด ๋งŽ์€ ๊ณ ์ธต๊ฑด๋ฌผ์— ์ ์šฉ๋˜์–ด ์™”๋‹ค[1],[2]

.

์ฝ˜ํฌ๋ฆฌํŠธ์ถฉ์ „ ๊ฐ•๊ด€(CFT)๊ธฐ๋‘ฅ์— ์‚ฌ์šฉ๋˜๋Š” ๊ฐํ˜•๊ฐ•๊ด€์€ ๊ฐ•

ํŒ 4๊ฐœ์˜ ๋ชจ์„œ๋ฆฌ๋ฅผ ์šฉ์ ‘ํ•˜์—ฌ ์ œ์ž‘ํ•˜๋Š” ๋ฐ•์Šคํ˜• ๊ธฐ๋‘ฅ์ด ์ผ๋ฐ˜

์ ์ด๋‚˜ ๋‘๊บผ์šด ๊ฐ•ํŒ์œผ๋กœ ์ œ์ž‘๋˜๋Š” ๊ฐ•๊ด€์€ ์ œ์ž‘ํšจ์œจ์ด ๋–จ์–ด

์งˆ ๋ฟ ์•„๋‹ˆ๋ผ ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜ ์ œ์ž‘ ์‹œ์—๋„ ํŠน๋ณ„ํ•œ ์šฉ์ ‘๊ธฐ

์ˆ ์ด ํ•„์š”ํ•˜์—ฌ ์ตœ๊ทผ ์–‡์€ ๊ฐ•ํŒ์„ ์ด์šฉํ•œ ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „๊ฐ•๊ด€

๊ธฐ๋‘ฅ์„ ๊ฐœ๋ฐœํ•˜๊ธฐ ์œ„ํ•œ ์—ฐ๊ตฌ๊ฐ€ ์ˆ˜ํ–‰๋˜์–ด ์™”๋‹ค[3],[4],[5],[6],[7]

. ๊ตญ

๋‚ด์—์„œ๋Š” ์ด์„ฑํฌ[8],[9],[10]

๊ฐ€ ์–‡์€ ๊ฐ•ํŒ์„ ์ ˆ๊ณกํ•œ ใ„ฑ์ž ํ˜•์ƒ์˜

๋‹จ์œ„๋ถ€์žฌ๋ฅผ ์„œ๋กœ ์šฉ์ ‘ํ•˜๋˜ ๊ตญ๋ถ€์ขŒ๊ตด์„ ์ง€์—ฐ์‹œํ‚ค๋Š” ์œ„์น˜์—

์Šคํ‹ฐํ”„๋„ˆ๊ฐ€ ์œ„์น˜๋˜๋„๋ก ํ•œ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€์„ ๊ฐœ๋ฐœํ•˜๊ณ 

๊ตฌ์กฐ๊ฑฐ๋™์„ ํ‰๊ฐ€ํ•˜์˜€์œผ๋ฉฐ, ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€ ๊ธฐ๋‘ฅ-๋ณด ์ ‘

ํ•ฉ๋ถ€์˜ ํ˜•์‹์œผ๋กœ ์™ธ๋‹ค์ด์•„ํ”„๋žจ์„ ์ œ์•ˆํ•˜๊ณ  ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•

CFT ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜ ์ธ์žฅ๋ ฅ์„ ๋ฐ›๋Š” ๋ถ€๋ถ„์„ ์ด์ƒํ™”ํ•œ ๋‹จ

์ˆœ์ธ์žฅ ์ ‘ํ•ฉ๋ถ€๋ฅผ ์ œ์ž‘ํ•˜์—ฌ ๊ตฌ์กฐ์‹คํ—˜์„ ์ˆ˜ํ–‰ํ•˜์˜€๋‹ค. ๊ทธ๋Ÿฌ๋‚˜

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ๊ฑฐ๋™์„ ๋ช…ํ™•ํžˆ ํŒŒ

์•…ํ•˜๊ธฐ ์œ„ํ•ด์„œ๋Š” ์‹ค๋Œ€ํ˜• ์‹คํ—˜์„ ์ˆ˜ํ–‰ํ•  ํ•„์š”๊ฐ€ ์žˆ์œผ๋ฉฐ, ๋ณธ

์—ฐ๊ตฌ์—์„œ๋Š” ์‹ค๋Œ€ํ˜• ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„

๋žจ ์ ‘ํ•ฉ๋ถ€ ์‹คํ—˜์ฒด 4๊ฐœ๋ฅผ ์ œ์ž‘ํ•˜์—ฌ ๊ตฌ์กฐ์‹คํ—˜์„ ์ˆ˜ํ–‰ํ•˜๊ณ  ๊ตฌ

Journal of Korean Society of Steel Construction

Vol.28, No.2, pp.75-83, April, 2016

ISSN(print) 1226-363X ISSN(online) 2287-4054

DOI http://dx.doi.org/10.7781/kjoss.2016.28.2.075

Page 2: Structural Behavior of Welded Built-up Square CFT Column ...

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ ๊ฑฐ๋™

76 ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›”

Fig. 1. Detail of external diaphragm

Table 1. Calculation of external diaphragmโ€™s Width()

Column

(mm)

Beam flange

(mm)B/t ts/t /B

Diaphragm

(mm)

Width

()

Thick.

()

โ–ก400ร—6 H-500ร—200ร—10ร—16 67 2.67 0.33 135 16

โ–ก400ร—9 H-588ร—300ร—12ร—20 44 2.22 0.5 200 20

Table 2. Material properties of analysis model for simple tension

specimens

Locations typeFy

(Mpa)

(GPa)

(GPa)

Poissonโ€™s

ratio (ฮผ)

Steel tube SM490 325

210 2.1 0.3Diaphragm

SS400 235Flange of

beam

์กฐ๊ฑฐ๋™์„ ๋ถ„์„ํ•˜์˜€๋‹ค.

2. ์ ‘ํ•ฉ๋ถ€ ๋‚ด๋ ฅ

๋ณธ ์—ฐ๊ตฌ์—์„œ๋Š” ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ

์ ‘ํ•ฉ๋ถ€์˜ ์ƒ์„ธ๋ฅผ ๊ฒฐ์ •ํ•˜๊ธฐ ์œ„ํ•ด ๊ธฐ๋‘ฅ-๋ณด ํ”Œ๋žœ์ง€์˜ ์šฉ์ ‘์œ ๋ฌด

๋ฐ ๊ธฐ๋‘ฅ-๋‹ค์ด์•„ํ”„๋žจ์˜ ์šฉ์ ‘๋Ÿ‰์„ ๋ณ€์ˆ˜๋กœ ์œ ํ•œ์š”์†Œํ•ด์„์„ ์ˆ˜

ํ–‰ํ•˜๊ณ  ๊ธฐ์กด ๋‹ค์ด์•„ํ”„๋žจ ์„ค๊ณ„์‹(๋Œ€ํ•œ๊ฑด์ถ•ํ•™ํšŒ[11]

๋ฐ ์ผ๋ณธ๊ฑด

์ถ•ํ•™ํšŒ[12]

)์„ ๋ถ„์„ํ•˜์—ฌ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€

์˜ ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์„ค๊ณ„์‹์„ ์ œ์•ˆํ•˜๊ณ ์ž ํ•œ๋‹ค.

2.1 ์„ค๊ณ„์‹ ์ œ์•ˆ

๋Œ€ํ•œ๊ฑด์ถ•ํ•™ํšŒ[1] ๋ฐ ์ผ๋ณธ๊ฑด์ถ•ํ•™ํšŒ

[6]์˜ ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์„ค๊ณ„

์‹์€ ๊ฑด์ถ•๊ตฌ์กฐ๊ธฐ์ค€์˜ ์ผ๋ถ€๋กœ ์‚ฌ์šฉ๋˜๋Š” ํ—ˆ์šฉ์‘๋ ฅ๋„ ์„ค๊ณ„์‹์œผ

๋กœ ๋‹จ๊ธฐ์™€ ์žฅ๊ธฐ ํ•˜์ค‘์— ๋Œ€ํ•˜์—ฌ ์‹ 1, ์‹ 2์™€ ๊ฐ™์ด ๊ตฌ์„ฑ๋˜์–ด ์žˆ

๋‹ค. ๊ทธ๋Ÿฌ๋‚˜ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€์€ ์™ธ๋‹ค์ด์•„ํ”„๋žจ๊ณผ ๊ฐ•๊ด€์˜ ๋‘

๊ป˜๋น„(/t)๊ฐ€ 2.67๋กœ ํ—ˆ์šฉ๋ฒ”์œ„์— ํฌํ•จ๋˜์ง€ ์•Š์œผ๋ฏ€๋กœ ์•„๋ž˜์˜

์„ค๊ณ„์‹์„ ๊ทธ๋Œ€๋กœ ์ ์šฉํ•˜๋Š” ๊ฒƒ์€ ์ ํ•ฉํ•˜์ง€ ์•Š๋‹ค.

๋‹จ๊ธฐ :

(1)

์žฅ๊ธฐ : (2)

์ ์šฉ๋ฒ”์œ„ : โ‰ค โ‰ค , โ‰ค โ‰ค , โ‰ฅ

๋‹จ๊ธฐ : โ‰ฅ, ์žฅ๊ธฐ : โ‰ฅ

: ๋ณด ํ”Œ๋žœ์ง€์˜ ํ—ˆ์šฉ๋‚ด๋ ฅ

: ๋‹ค์ด์•„๋žจ์˜ ํ—ˆ์šฉ์‘๋ ฅ

: ๊ธฐ๋‘ฅ๊ฐ•๊ด€์˜ ํ—ˆ์šฉ์‘๋ ฅ

: ๋‹ค์ด์•„ํ”„๋žจ์˜ ์„ค๊ณ„ํ•ญ๋ณต๊ฐ•๋„

: ๊ธฐ๋‘ฅ๊ฐ•๊ด€์˜ ์„ค๊ณ„ํ•ญ๋ณต๊ฐ•๋„

๋”ฐ๋ผ์„œ ๊ฐํ˜•๊ฐ•๊ด€์˜ ์–‡์€ ๊ธฐ๋‘ฅ๋ฉด์œผ๋กœ ์ „๋‹ฌ๋˜๋Š” ๋‚ด๋ ฅ๋ถ€๋ฅผ

์‹ 2์—์„œ ์‚ญ์ œํ•˜๊ณ  ๋‹ค์ด์•„ํ”„๋žจ์˜ ๋‚ด๋ ฅ๋ถ€๋งŒ์œผ๋กœ ์„ค๊ณ„ํ•˜๋Š” ๊ฒƒ

์ด ๋ฐ”๋žŒ์งํ•˜๋ฉฐ ์ˆ˜์ •๋œ ์™ธ๋‹ค์ด์•„ํ”„๋žจ์˜ ๋‚ด๋ ฅ์‹์€ ์‹ 3๊ณผ ๊ฐ™

๋‹ค. ์‹ 3์— ๋”ฐ๋ผ โ–ก 400ร—6 ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ธฐ๋‘ฅ๊ณผ H-500ร—

200ร—10ร—16 ๋ณด์— ๋Œ€ํ•œ ๋‹ค์ด์•„ํ”„๋žจ ํญ()์€ 135mm, โ–ก

400ร—9 ๊ธฐ๋‘ฅ๊ณผ H-588ร—300ร—12ร—20 ๋ณด์— ๋Œ€ํ•œ ๋‹ค์ด์•„ํ”„๋žจ

ํญ()์€ 200mm์œผ๋กœ ์‚ฐ์ถœ๋˜์—ˆ๋‹ค.

์žฅ๊ธฐ : (3)

2.2 ์„ค๊ณ„์‹ ๊ฒ€์ฆ

์ œ์•ˆ๋œ ์„ค๊ณ„์‹์˜ ๊ฒ€์ฆ์„ ์œ„ํ•ด ๋ฒ”์šฉ ์œ ํ•œ์š”์†Œ ํ•ด์„ํ”„๋กœ๊ทธ

๋žจ์ธ ANSYS 10.0์„ ์‚ฌ์šฉํ•˜์—ฌ ๊ตฌ์กฐํ•ด์„์„ ์ˆ˜ํ–‰ํ•˜์˜€๋‹ค. ํ•ด

์„๋Œ€์ƒ์€ โ–ก 400ร—6(SM490) ๊ฐ•๊ด€๊ณผ H-500ร—200ร—10ร—16

๋ณด์˜ ์ƒ๋ถ€ ๋ณดํ”Œ๋žœ์ง€(PL-200ร—16)์— ๋‹ค์ด์•„ํ”„๋žจ ํญ()์ด

135mm์ธ ๋‹ค์ด์•„ํ”„๋žจ์ด ์ ‘ํ•ฉ๋œ ๋‹จ์ˆœ์ธ์žฅ ์ ‘ํ•ฉ๋ถ€๋กœ ํ•˜์˜€๋‹ค.

๊ฐ•์žฌ์˜ ์‘๋ ฅ-๋ณ€ํ˜•๋ฅ  ํŠน์„ฑ์€ VonMises์˜ ํ•ญ๋ณต๊ธฐ์ค€๊ณผ Bi-linear

Kinematic Hardening๋ชจ๋ธ์„ ์‚ฌ์šฉํ•˜๊ณ  ๊ฐ•์žฌ์˜ ํ•ญ๋ณต ํ›„์˜

์ ‘์„ ๊ณ„์ˆ˜()๋Š” ํƒ„์„ฑ๊ณ„์ˆ˜()์˜ 1/100๋กœ ๊ฐ€์ •ํ•˜์˜€๋‹ค. ์‚ฌ์šฉ

๋œ ์žฌ๋ฃŒ๋Š” Table 2์™€ ๊ฐ™์ด ์ผ๋ฐ˜์ ์ธ ๊ฐ•์žฌ์˜ ๊ฐ•๋„ ๊ฐ’์„ ์‚ฌ์šฉ

ํ•˜์˜€๋‹ค.

Page 3: Structural Behavior of Welded Built-up Square CFT Column ...

์ด์„ฑํฌ๏ฝฅ ๊น€์˜ํ˜ธ๏ฝฅ ์ตœ์„ฑ๋ชจ

ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›” 77

Fig. 2. Load-disp. relations of analysis specimens

(a) Welding of Column-Beam Flange(O), Welding of

Column-Diaphragm(O)

(b) Welding of Column-Beam Flange(X), Welding of

Column-Diaphragm(O)

Fig. 3. Stress distribution

(a) Plan view

(b) Side view

Fig. 4. HBC-1, 3

(a) Plan view

(b) Side view

Fig. 5. HBC-2(No diaphragm in the lower flange of beam)

๊ธฐ๋‘ฅ๊ณผ ๋ณด ํ”Œ๋žœ์ง€์˜ ์šฉ์ ‘์œ ๋ฌด, ๊ธฐ๋‘ฅ๊ณผ ๋‹ค์ด์•„ํ”„๋žจ์˜ ์šฉ์ ‘

์œ ๋ฌด๋ฅผ ๋ณ€์ˆ˜๋กœ ํ•ด์„์„ ์ˆ˜ํ–‰ํ•˜์—ฌ Fig. 2์— ํ•ด์„๋Œ€์ƒ์˜ ํ•˜์ค‘-

๋ณ€์œ„๊ด€๊ณ„๋ฅผ ๋‚˜ํƒ€๋‚ด๊ณ  Fig. 3์— ๋ณดํ”Œ๋žœ์ง€ ํ•ญ๋ณตํ•˜์ค‘์—์„œ Von

Mises ์‘๋ ฅ๋ถ„ํฌ๋ฅผ ๋‚˜ํƒ€๋‚ด์—ˆ๋‹ค. ํ•ด์„๊ฒฐ๊ณผ์—์„œ ๊ธฐ๋‘ฅ๊ณผ ๋‹ค์ด

์•„ํ”„๋žจ์˜ ์šฉ์ ‘์€ ์ ‘ํ•ฉ๋ถ€์˜ ๋‚ด๋ ฅ๊ณผ ๊ฐ•์„ฑ์— ํฐ ์˜ํ–ฅ์„ ๋ฏธ์น˜๋Š”

๋ฐ˜๋ฉด ๊ธฐ๋‘ฅ๊ณผ ๋ณด ํ”„๋žœ์ง€์˜ ์šฉ์ ‘์œ ๋ฌด๋Š” ์ ‘ํ•ฉ๋ถ€์˜ ๋‚ด๋ ฅ๊ณผ ๊ฐ•์„ฑ

์— ์˜ํ–ฅ์ด ์ ์€ ๊ฒƒ์œผ๋กœ ๋‚˜ํƒ€๋‚ฌ์œผ๋ฉฐ, ๋ณดํ”Œ๋žœ์ง€ ํ•˜์ค‘์„ ๋‹ค์ด์•„

ํ”„๋žจ์˜ ๋‚ด๋ ฅ๋งŒ์œผ๋กœ ์ €ํ•ญํ•˜๋„๋ก ์„ค๊ณ„ํ•˜๋Š” ์ œ์•ˆ๋œ ์„ค๊ณ„์‹(์‹ 1

๋ฐ ์‹ 2)์€ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ

๋ถ€์˜ ์„ค๊ณ„์‹์œผ๋กœ ์‚ฌ์šฉ์ด ๊ฐ€๋Šฅํ•˜๋‹ค๊ณ  ํŒ๋‹จ๋œ๋‹ค.

3. ์‹ค ํ—˜

3.1 ์‹คํ—˜์ฒด ๊ณ„ํš

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€ ์‹คํ—˜์ฒด๋Š” ๋ณดํ”„๋žœ์ง€์˜

ํ•ญ๋ณต๊ฐ•๋„๋ฅผ ๊ธฐ์ค€์œผ๋กœ ์œ„ 2.1์—์„œ ์ œ์•ˆํ•œ ๋‹ค์ด์•„ํ”„๋žจ ์„ค๊ณ„์‹

Page 4: Structural Behavior of Welded Built-up Square CFT Column ...

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ ๊ฑฐ๋™

78 ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›”

Table 3. Specimens of column-beam connections

SpecimensColumn

[SM490]

Beam

[SS400]

Diaphragm[SS400]Welding of

column-beam flangeWelding of

Diaphragm-

Column

30MPa

Conโ€™c in the

columnupper lowerwidth

(mm)

Thick.

(mm)upper lower

HBC-1 โ–ก-400ร—6 H-500ร—200ร—10ร—16 O O 135 16 X X O Filled

HBC-2 โ–ก-400ร—6 H-500ร—200ร—10ร—16 O X 135 16 X O O Filled

HBC-3 โ–ก-400ร—6 H-500ร—200ร—10ร—16 O O 135 16 X X O Non-Filled

HBC-4 โ–ก-400ร—9 H-588ร—300ร—12ร—20 O O 200 20 X X O Filled

(a) Plan view

(b) Side view

Fig. 6. HBC-4

Fig. 7. Setting plan of Specimens

(a) Location of LVDT

(b) Strain gage(upper) (c) Strain gage(lower)

(d) Strain gage(front) (e) Strain gage(side)

Fig. 8. Location of Strain gage and LVDT

(์‹ 3)์„ ์ด์šฉํ•˜์—ฌ ๋ณด ํ•˜๋ถ€ํ”Œ๋žœ์ง€์˜ ์™ธ๋Œ€์ด์•„ํ”„๋žจ ์กด์žฌ์œ ๋ฌด,

์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „์œ ๋ฌด, ๋ณด ํ”Œ๋žœ์ง€์™€ ๊ฐ•๊ด€์˜ ํญ๋น„๋ฅผ ๋ณ€์ˆ˜๋กœ 4๊ฐœ

์˜ ์‹คํ—˜์ฒด๋ฅผ ์ œ์ž‘ํ•˜์˜€๋‹ค. ์‹คํ—˜์ฒด์— ์‚ฌ์šฉ๋œ ๊ฐ•์ข…์€ ๊ธฐ๋‘ฅ์€

SM490, ๋ณด์™€ ๋‹ค์ด์•„ํ”„๋žจ์€ SS400๊ฐ•์žฌ๋ฅผ ์‚ฌ์šฉํ•˜์˜€๋‹ค. ์‹คํ—˜

์ฒด ์ œ์ž‘์— ์žˆ์–ด์„œ ๊ธฐ๋‘ฅ๊ณผ ๋ณด ํ”Œ๋žœ์ง€ ์šฉ์ ‘์„ ์ œ์™ธํ•œ ๋ชจ๋“  ์šฉ์ ‘

๋ถ€๋Š” E71T-1 ร˜1.6mm ์ „๊ทน๋ด‰์„ ์‚ฌ์šฉํ•œ FCAW (Flux-Cored

Arc Welding)์œผ๋กœ ์šฉ์ ‘ํ•˜์˜€์œผ๋ฉฐ, ๊ฐ•๊ด€๊ณผ ๋ณด ํ”Œ๋žœ์ง€ ์šฉ์ ‘๋ถ€

๋Š” E7018 ร˜1.8mm ์ „๊ทน๋ด‰์„ ์‚ฌ์šฉํ•œ SMAW(Shielded Metal

Arc Welding)์œผ๋กœ ์šฉ์ ‘ํ•˜์˜€๋‹ค. ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€์— ์ถฉ์ „

๋˜๋Š” ์ฝ˜ํฌ๋ฆฌํŠธ๋Š” 28์ผ ์••์ถ•๊ฐ•๋„๊ฐ€ 30MPa๊ฐ€ ๋˜๋„๋ก ๊ณ„ํšํ•˜

์˜€์œผ๋ฉฐ, ์‹คํ—˜์ฒด์˜ ๋ฆฌ์ŠคํŠธ ๋ฐ ์ƒ์„ธ์น˜์ˆ˜๋Š” Table 3 ๋ฐ Fig. 4

๋‚ด์ง€ Fig. 6์— ๋‚˜ํƒ€๋‚ด์—ˆ๋‹ค.

3.2 ์‹คํ—˜์ฒด ์„ธํŒ… ๋ฐ ๊ฐ€๋ ฅ๋ฐฉ๋ฒ•

์‹คํ—˜์ฒด ์„ธํŒ…์€ Fig. 7๊ณผ ๊ฐ™์ด ๊ธฐ๋‘ฅ ์ƒ โ€ค ํ•˜ ๋๋‹จ ํ”Œ๋ ˆ์ดํŠธ

๋ฅผ ๋ฐ˜๋ ฅ๋ฒฝ์— ์„ค์น˜ํ•œ ํžŒ์ง€์— ์—ฐ๊ฒฐํ•˜๊ณ  ๊ฐ€๋ ฅ ์ ์— ์ƒ โ€ค ํ•˜ ๋ฐ˜๋ณต

Page 5: Structural Behavior of Welded Built-up Square CFT Column ...

์ด์„ฑํฌ๏ฝฅ ๊น€์˜ํ˜ธ๏ฝฅ ์ตœ์„ฑ๋ชจ

ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›” 79

Fig. 9. Setting scene of Specimens

Table 4. Results of material Property tests

Spec-

imenstype

Thick.

(mm)

(MPa)

(MPa)

(%)

Elong.

(%)

Steel

tube

SM

490

6 384 487 78.8 23.9

9 431 533 80.1 22.7

Dia-

phragm

SS

400

16 298 423 70.4 31.5

20 302 432 69.9 22.9

Hbeam-

web

10 356 499 71.3 25.1

12 303 419 72.3 27.5

Hbeam-

flange

16 338 498 67.8 25.6

20 275 406 67.7 29.8

Table 5. Concrete Compressive Strength

Concrete

specimens

7 day strength

(MPa)

14 day strength

(MPa)

28 day strength

(Mpa)

Average 13.70 17.05 22.05

(a) HBC-1

(b) HBC-2

(c) HBC-3

(d) HBC-4

Fig. 10. Load-disp. relations of Specimens

๊ฐ€๋ ฅ์ด ๊ฐ€๋Šฅํ•œ 2,000kN๊ธ‰ ์—‘์ธ„์—์ดํ„ฐ๋ฅผ ๋ถ€์ฐฉํ•˜์˜€๋‹ค. ๋˜ํ•œ

๊ฐ€๋ ฅ ์‹œ ๋ณด์˜ ํšก์ขŒ๊ตด ๋ฐฉ์ง€๋ฅผ ์œ„ํ•œ ์ขŒ๊ตด ๋ฐฉ์ง€๋Œ€๋ฅผ ๊ฐ€๋ ฅ์ ์—์„œ

์•ˆ์ชฝ๋ฐฉํ–ฅ์œผ๋กœ 1m๊ฐ€๋Ÿ‰ ๋–จ์–ด์ง„ ์ง€์ ์— ์–‘์ชฝ์œผ๋กœ ์„ค์น˜ํ•˜์˜€๋‹ค.

๋ณ€์œ„๊ณ„์™€ ๋ณ€ํ˜•๋ฅ  ๊ฒŒ์ด์ง€๋Š” ์‹คํ—˜์ฒด์˜ ์ „์ฒด์ ์ธ ๊ฑฐ๋™๊ณผ ๋ณ€

ํ˜•๋ฅ ์„ ํ‰๊ฐ€ํ•˜๊ธฐ ์œ„ํ•ด Fig. 8๊ณผ ๊ฐ™์ด ์„ค์น˜ํ•˜์˜€์œผ๋ฉฐ, ์‹คํ—˜์ฒด

์„ธํŒ…์žฅ๋ฉด์€ Fig. 9๊ณผ ๊ฐ™๋‹ค.

ํ•˜์ค‘์˜ ๊ฐ€๋ ฅ ๋ฐฉ๋ฒ•์€ Seismic Provisions for Structural

Steel Buildings[13]

์˜ ์ ‘ํ•ฉ๋ถ€ ๋‚ด์ง„์„ฑ๋Šฅํ‰๊ฐ€๋ฅผ ์œ„ํ•œ Cyclic

Loading Program์„ ์‚ฌ์šฉํ•˜์˜€๋‹ค.

3.3 ์‹คํ—˜๊ฒฐ๊ณผ

3.3.1 ์žฌ๋ฃŒ์‹œํ—˜๊ฒฐ๊ณผ

์‹คํ—˜์ฒด ์ œ์ž‘์— ์‚ฌ์šฉ๋œ ์žฌ๋ฃŒ์˜ ๊ธฐ๊ณ„์  ์„ฑ์งˆ์„ ์•Œ์•„๋ณด๊ธฐ ์œ„

ํ•˜์—ฌ KS B0801 ๊ทœ์ค€์— ๋”ฐ๋ผ ๊ฐ๊ฐ 3๊ฐœ์”ฉ ์ธ์žฅ ์‹œํ—˜ํŽธ์„ ์ ˆ์ทจ

ํ•˜์—ฌ ์ธ์žฅ ์‹œํ—˜์„ ์ˆ˜ํ–‰ํ•˜์˜€๋‹ค. ๋ณธ ์‹คํ—˜์— ์‚ฌ์šฉ๋œ ์žฌ๋ฃŒ๋Š” SS400

์˜ ๋‘๊ป˜ 10mm, 12mm, 16mm, 20mm์™€ SM490์˜ ๋‘๊ป˜

6mm, 9mm์˜ ๊ฐ•์žฌ์ด๋‹ค. ๊ฐ ์‹œํ—˜ํŽธ์˜ ์‹œํ—˜๊ฒฐ๊ณผ๋Š” Table 4

์— ๋‚˜ํƒ€๋‚ด์—ˆ์œผ๋ฉฐ, ์ฝ˜ํฌ๋ฆฌํŠธ ๊ณต์‹œ์ฒด์— ๋Œ€ํ•œ 28์ผ ์••์ถ•๊ฐ•๋„์˜

์‹œํ—˜๊ฒฐ๊ณผ๋ฅผ Table 5์— ๋‚˜ํƒ€๋‚ด์—ˆ๋‹ค.

3.3.2 ๊ตฌ์กฐ์‹คํ—˜๊ฒฐ๊ณผ

๊ฐ ์‹คํ—˜์ฒด์˜ ์—‘์ธ„์—์ดํ„ฐ์˜ ๊ฐ€๋ ฅ์ ์— ์ˆ˜์ง๋ฐฉํ–ฅ์œผ๋กœ ์„ค์น˜

ํ•œ ๋ณ€์œ„๊ณ„ 1๊ณผ ํ•˜์ค‘๊ณผ์˜ ๊ด€๊ณ„๋ฅผ Fig. 10์— ์„ค๊ณ„ํ•ญ๋ณตํ•˜์ค‘

(), ์„ค๊ณ„์ „์†Œ์„ฑํ•˜์ค‘()์™€ ํ•จ๊ป˜ ๋‚˜ํƒ€๋‚ด์—ˆ๋‹ค. ์—ฌ๊ธฐ์„œ ๊ฐ•

Page 6: Structural Behavior of Welded Built-up Square CFT Column ...

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ ๊ฑฐ๋™

80 ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›”

Table 6. Test results

Spec-imens

The initial

stiffness(kN/mm)

(kN)

(kN)

Yield resistance of spec-

imens

(kN)

Ultimate resistance of Spec-

imens

(kN)

Failure mode

+ - + -

HBC-

14.98

128 146

134 140 207 231Diaphragm

failure

HBC-

23.76 123 35 189 75

lower beam-

diaphragmjoint

failure

HBC-

34.12 107 126 179 184

Diaphragmfailure

HBC-

49.45 270 301 221 200 311 312

Diaphragmfailure

๊ด€๊ณผ ๋ณด์˜ ํฌ๊ธฐ๊ฐ€ ๋‹ค๋ฅธ HBC-4์™€ ํ•˜๋ถ€์— ๋‹ค์ด์•„ํ”„๋žจ์„ ์„ค์น˜

ํ•˜์ง€ ์•Š์€ HBC-2๋ฅผ ์ œ์™ธํ•˜๊ณ  ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „ ์œ /๋ฌด์— ๊ด€๊ณ„

์—†์ด ๋น„์Šทํ•œ ๊ฑฐ๋™์„ ๋‚˜ํƒ€๋‚ด์—ˆ์œผ๋ฉฐ, ๊ฐ ์‹คํ—˜์ฒด์˜ ๊ฑฐ๋™์€ ์•„๋ž˜

์™€ ๊ฐ™๋‹ค.

(1) HBC-1์˜ ๊ฑฐ๋™

HBC-1์€ ๊ฐ€๋ ฅ์ด ์‹œ์ž‘๋˜๊ณ  Step-3๊นŒ์ง€๋Š” ์™ธ๊ด€์ƒ์œผ๋กœ ์•„

๋ฌด ๋ณ€ํ™”๊ฐ€ ์ผ์–ด๋‚˜์ง€ ์•Š์•˜์œผ๋ฉฐ Step-4์—์„œ๋Š” ๋ณด ํ”Œ๋žœ์ง€์˜ ๊ฒ‰

ํ‘œ๋ฉด์ด ๋ฒ—๊ฒจ์ง€๋ฉด์„œ ์•ฝ๊ฐ„์˜ ๋น„ํ‹€๋ฆผ์œผ๋กœ ์ธํ•œ ์†Œ๋ฆฌ๊ฐ€ ๋ฐœ์ƒํ•˜

๊ธฐ ์‹œ์ž‘ํ•˜์˜€๋‹ค. Step-7์˜ 1์‚ฌ์ดํด(0.03rad)์—์„œ +๋ฐฉํ–ฅ์˜

์ตœ๋Œ€๋‚ด๋ ฅ์— ๋„๋‹ฌํ•˜์˜€์œผ๋ฉฐ ๋ฐ˜๋ณต๊ฐ€๋ ฅ์— ์˜ํ•œ ์™ธ๋‹ค์ด์•„ํ”„๋žจ์˜

ํœจ์ด ์œก์•ˆ์œผ๋กœ ๊ด€์ฐฐ๋˜์—ˆ๋‹ค. ๋‹ค์Œ์œผ๋กœ Step-8์˜ 2์‚ฌ์ดํด

(0.04rad)์˜ -๋ฐฉํ–ฅ์—์„œ ์ตœ๋Œ€๋‚ด๋ ฅ์— ๋„๋‹ฌํ•˜์˜€์œผ๋ฉฐ, Step-9

์˜ 1์‚ฌ์ดํด์—์„œ ์ƒ๋ถ€ ์˜ค๋ฅธ์ชฝ ๋‹ค์ด์•„ํ”„๋žจ์˜ ๊ฐ•๊ด€๊ณผ ๋งž๋‹ฟ์•„ ์žˆ

๋Š” ์šฉ์ ‘๋ถ€ ๋ชจ์„œ๋ฆฌ ๋์—์„œ ๊ท ์—ด์ด ๋ฐœ์ƒํ•œ ํ›„ 2์‚ฌ์ดํด์—์„œ ์™ธ

๋‹ค์ด์•„ํ”„๋žจ์˜ ๋Œ€๊ฐ์„  ๋ฐฉํ–ฅ์œผ๋กœ ํŒŒ๋‹จ์ด ๋ฐœ์ƒํ•˜๋ฉฐ ์ตœ์ข…์ ์ธ

ํŒŒ๊ดด์— ์ด๋ฅด๋ €๋‹ค.

Fig. 11. HBC-1 (cracking at lower diaphragm during 0.05rad)

(2) HBC-2

HBC-2๋Š” +๋ฐฉํ–ฅ ๊ฐ€๋ ฅ์‹œ Step-3์˜ 6์‚ฌ์ดํด(0.0075rad)

๊นŒ์ง€๋Š” ํƒ„์„ฑ์ ์ธ ๊ฑฐ๋™์„ ๋ณด์˜€๊ณ  ๊ทธ ์ดํ›„๋กœ๋Š” ํƒ„์†Œ์„ฑ ๊ฑฐ๋™์„

๋ณด์ด๋ฉด์„œ ๋‚ด๋ ฅ์ด ์ƒ์Šนํ•˜์˜€๋‹ค. ์‹คํ—˜์ฒด์˜ ๋‚ด๋ ฅ์€ +๋ฐฉํ–ฅ ๊ฐ€๋ ฅ

์‹œ 0.03rad ์ดํ›„ ์ผ์ •ํ•˜๊ฑฐ๋‚˜ ์†Œํญ ์ƒ์Šนํ•˜์˜€์ง€๋งŒ -๋ฐฉํ–ฅ ๊ฐ€๋ ฅ

์‹œ์—๋Š” 0.03rad ์ดํ›„ ๋‚ด๋ ฅ์ด ๊ฐ์†Œํ•˜๋Š” ๊ฒฝํ–ฅ์„ ๋ณด์˜€๋‹ค. Step-7

์˜ 1์‚ฌ์ดํด(0.03rad)์˜ -๋ฐฉํ–ฅ ๊ฐ€๋ ฅ ์‹œ ํ•˜๋ถ€ ํ”Œ๋žœ์ง€ ์šฉ์ ‘ ๋ถ€

๋๋‹จ์—์„œ ๊ฐ•๊ด€๋ฉด์˜ ํŒŒ๋‹จ์ด ์‹œ์ž‘๋˜์—ˆ๊ณ  Step-8์˜ 2์‚ฌ์ดํด

(0.04rad)์—์„œ ๊ฐ•๊ด€ ๋ฉด์ด 5cm๊ฐ€๋Ÿ‰ ํŒŒ๋‹จ ๋˜์—ˆ์œผ๋ฉฐ ์ƒ๋ถ€ ์™ธ๋‹ค

์ด์•„ํ”„๋žจ์€ ์•ฝ๊ฐ„์˜ ํœจ ๋ณ€ํ˜•์„ ๋ณด์˜€๋‹ค. ์‹คํ—˜์ฒด๋Š” ๊ฐ™์€ ๋‚ด๋ ฅ์„

์œ ์ง€ํ•˜๋ฉฐ ๊ฑฐ๋™ํ•˜๋‹ค๊ฐ€ Step-10์˜ 2์‚ฌ์ดํด์—์„œ ํ•˜๋ถ€ ํ”Œ๋žœ์ง€

์™€ ๋งž๋‹ฟ์•„ ์žˆ๋Š” ๊ฐ•๊ด€๋ฉด์ด ์ฝ˜ํฌ๋ฆฌํŠธ ์†์— ๋ฌปํ˜€์žˆ๋Š” ์•ต์ปค์™€ ๋ถ„

๋ฆฌ๋˜๋ฉด์„œ ์ตœ์ข…์ ์ธ ํŒŒ๊ดด์— ๋„๋‹ฌํ•˜์˜€๋‹ค.

Fig. 12. HBC-2 (failure at lower steel tube during 0.06rad)

(3) HBC-3

HBC-3์€ Step-3(0.0075rad)๊นŒ์ง€๋Š” ํƒ„์„ฑ๊ฑฐ๋™์„ ๋ณด์ด

๋‹ค ๊ทธ ์ดํ›„๋กœ๋Š” ํƒ„์†Œ์„ฑ๊ฑฐ๋™์œผ๋กœ ์ง„ํ–‰๋˜์—ˆ๋‹ค. ์ดํ›„ Step-7

์˜ 2์‚ฌ์ดํด์—์„œ ์ƒ โ€ค ํ•˜๋ถ€ ๋‹ค์ด์•„ํ”„๋žจ์˜ ํœจ์ด ์œก์•ˆ์œผ๋กœ ๊ด€์ฐฐ

๋˜์—ˆ์œผ๋ฉฐ ๋ฐ˜๋ณต๋œ ํœจ์— ๋”ฐ๋ฅธ ํŒŒ๊ดด๊ฐ€ Step-8์˜ 2์‚ฌ์ดํด์—์„œ

์ƒ๋ถ€ ์˜ค๋ฅธ์ชฝ ๋‹ค์ด์•„ํ”„๋žจ์˜ ํŒŒ๋‹จ์œผ๋กœ ์‹คํ—˜์ด ์ข…๋ฃŒ๋˜์—ˆ๋‹ค.

Fig. 13. HBC-3 (failure at upper diaphragm during 0.04rad)

Page 7: Structural Behavior of Welded Built-up Square CFT Column ...

์ด์„ฑํฌ๏ฝฅ ๊น€์˜ํ˜ธ๏ฝฅ ์ตœ์„ฑ๋ชจ

ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›” 81

(a) HBC-1

Fig. 17. M-ฮธ relations of specimens after 0.04rad

(4) HBC-4

HBC-4์€ Step 4 ์ดํ›„๋กœ ํƒ„์†Œ์„ฑ๊ฑฐ๋™์„ ๋ณด์˜€์œผ๋ฉฐ ์ตœ๋Œ€๋‚ด๋ ฅ

์€ +๋ฐฉํ–ฅ ๋ฐ -๋ฐฉํ–ฅ ๊ฐ€๋ ฅ ์‹œ ๋ชจ๋‘ Step7์˜ 2์‚ฌ์ดํด(0.03rad)

์—์„œ ๋‚˜ํƒ€๋‚ฌ๋‹ค. Step8์˜ 1์‚ฌ์ดํด์—์„œ ๋ณด ํ”Œ๋žœ์ง€์™€ ํ•˜๋ถ€ ์™ธ

๋‹ค์ด์•„ํ”„๋žจ์ด ๋งŒ๋‚˜๋Š” ๊ฒฝ๊ณ„์„ ์—์„œ ์–‘์ชฝ ์™ธ๋‹ค์ด์•„ํ”„๋žจ ๋ชจ๋‘

๊ท ์—ด์ด ๋ฐœ์ƒํ•˜์˜€๊ณ  Step9์˜ 1์‚ฌ์ดํด์—์„œ ๋‹ค์ด์•„ํ”„๋žจ์˜ ์™„์ „

ํŒŒ๋‹จ ๋ฐ ์ „ํƒ„ ํƒญ ์šฉ์ ‘๋ถ€๊ฐ€ ํŒŒ๋‹จ ๋จ์œผ๋กœ์จ ์‹คํ—˜์ด ์ข…๋ฃŒ๋˜์—ˆ๋‹ค.

Fig. 14. HBC-4 (failure at lower diaphragm during 0.04rad)

4. ๋ถ„์„ ๋ฐ ๊ณ ์ฐฐ

4.1 ์ดˆ๊ธฐ๊ฐ•์„ฑ

๊ฐ ์‹คํ—˜์ฒด์˜ ์ดˆ๊ธฐ๊ฐ•์„ฑ ๊ฐ’์„ Fig. 15์— ๋‚˜ํƒ€๋‚ด์—ˆ๋‹ค. HBC-1

์„ ๋ฌด์ถฉ์ „ ์‹คํ—˜์ฒด์ธ HBC-3๊ณผ ๋น„๊ตํ•˜๋ฉด ๋‚ด๋ถ€์— ์ฝ˜ํฌ๋ฆฌํŠธ๊ฐ€

์ถฉ์ „์ด ๋˜์—ˆ์„ ๊ฒฝ์šฐ ์ดˆ๊ธฐ๊ฐ•์„ฑ ๊ฐ’์ด ์†Œํญ ์ƒ์Šนํ•จ์„ ์•Œ ์ˆ˜ ์žˆ๊ณ 

์ด๋Š” ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜ ๋ฐ˜๋ณต ๊ฐ€๋ ฅ ์‹œ ๋‚ด๋ถ€์— ์กด์žฌํ•˜๋Š” ์•ต์ปค

์™€ ์ฝ˜ํฌ๋ฆฌํŠธ์™€์˜ ํ•ฉ์„ฑํšจ๊ณผ์— ๊ธฐ์ธํ•œ ๊ฒƒ์œผ๋กœ ํŒ๋‹จ๋œ๋‹ค. ๋ณด ํ”Œ

๋žœ์ง€์™€ ๋‹ค์ด์•„ํ”„๋žจ์˜ ํญ๊ณผ ๋‘๊ป˜๋ฅผ ์ฆ๊ฐ€์‹œํ‚จ HBC-4์˜ ์ดˆ๊ธฐ

๊ฐ•์„ฑ์€ HBC-1์— ๋น„ํ•ด 1.9๋ฐฐ๋กœ ํฌ๊ฒŒ ๋‚˜ํƒ€๋‚ฌ๋‹ค.

Fig. 15. Comparison of specimenโ€™s initial stiffness)

4.2 ์ตœ๋Œ€๋‚ด๋ ฅ

Fig. 16์€ ๊ฐ ์‹คํ—˜์ฒด์˜ ์ตœ๋Œ€๋‚ด๋ ฅ์„ ๋น„๊ตํ•˜๊ธฐ ์œ„ํ•ด ๋ฐ˜๋ณต๊ฐ€

๋ ฅ ์‹คํ—˜ ๊ฒฐ๊ณผ๋ฅผ ๋‹จ์กฐ๊ฐ€๋ ฅ ์‹คํ—˜ ๊ฒฐ๊ณผ์˜ ํ˜•์ƒ๊ณก์„ ์œผ๋กœ ๊ทผ์‚ฌํ™”

ํ•˜์—ฌ ํ•˜์ค‘-๋ณ€์œ„ ๊ด€๊ณ„๋กœ ๋‚˜ํƒ€๋‚ธ ๊ฒƒ์ด๋‹ค. ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „ํ˜•์ธ

HBC-1์˜ +๋ฐฉํ–ฅ ์ตœ๋Œ€๋‚ด๋ ฅ(207kN)์€ ๋ฌด์ถฉ์ „ ์‹คํ—˜์ฒด HBC-3

์˜ +๋ฐฉํ–ฅ ์ตœ๋Œ€๋‚ด๋ ฅ(179kN)์— ๋น„ํ•ด 28kN ์ƒ์Šนํ•˜์˜€๊ณ  ํ•˜๋ถ€

์— ๋‹ค์ด์•„ํ”„๋žจ์ด ์„ค์น˜๋˜์ง€ ์•Š์€ HBC-2๋„ +๋ฐฉํ–ฅ ๊ฐ€๋ ฅ ์‹œ ๋ณด

ํ”Œ๋žœ์ง€๊ฐ€ ๊ฐ•๊ด€๋ฉด์— ๊ฐ€ํ•˜๋Š” ์••์ถ•๋ ฅ์„ ๋‚ด๋ถ€ ์ฝ˜ํฌ๋ฆฌํŠธ๊ฐ€ ์ €ํ•ญ

ํ•˜๊ธฐ ๋•Œ๋ฌธ์— ์ƒํ•˜๋™ํ˜• ์‹คํ—˜์ฒด์˜ ๊ฒฐ๊ณผ์™€ ๋น„์Šทํ•œ 189kN์˜ ์ตœ

๋Œ€๋‚ด๋ ฅ์„ ๋ฐœํœ˜ํ•˜์˜€๋‹ค. ๊ฐ•๊ด€์˜ ๋‘๊ป˜, ๋ณด์˜ ํฌ๊ธฐ ๋ฐ ์™ธ๋‹ค์ด์•„

ํ”„๋žจ ํญ์„ ์ฆ๊ฐ€์‹œํ‚จ HBC-4๋Š” +๋ฐฉํ–ฅ ๊ฐ€๋ ฅ์‹œ 311kN์˜ ์ตœ๋Œ€

๋‚ด๋ ฅ์„ ๋‚˜ํƒ€๋‚ด์—ˆ๋‹ค.

Fig. 16. Comparison of specimenโ€™s ultimate resistance

4.3 ์ ‘ํ•ฉ๋ถ€์˜ ๋‚ด์ง„์„ฑ๋Šฅ

๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€๋Š” ์ง€์ง„ ๋ฐœ์ƒ์‹œ ๊ฑด๋ฌผ์— ์ž…๋ ฅ๋˜๋Š” ์—๋„ˆ์ง€

๋ฅผ ํก์ˆ˜ํ•  ์ˆ˜ ์žˆ๋„๋ก ์ผ์ •ํ•œ ์†Œ์„ฑ๋ณ€ํ˜•๋Šฅ๋ ฅ์ด ํ™•๋ณด๋˜์–ด์•ผ ํ•œ

๋‹ค. ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๋‚ด

์ง„ ์„ฑ๋Šฅ์„ ๋ถ„์„์„ ์œ„ํ•ด ๊ฐ ์‹คํ—˜์ฒด์˜ ๋ชจ๋ฉ˜ํŠธ ํšŒ์ „๊ฐ ๊ณก์„ ์„

Fig. 17์— ๋‚˜ํƒ€๋‚ด์—ˆ์œผ๋ฉฐ, HBC-4๊ฐ€ ๋‹ค์†Œ ๋ถˆ์•ˆ์ •ํ•œ ์ด๋ ฅ์„

๋‚˜ํƒ€๋‚ด๋Š” ์ ์„ ์ œ์™ธํ•˜๊ณ  ๋‚˜๋จธ์ง€ ์‹คํ—˜์ฒด ๋ชจ๋‘ 0.04rad์ด์ƒ์˜

Page 8: Structural Behavior of Welded Built-up Square CFT Column ...

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐ ๊ฑฐ๋™

82 ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›”

(b) HBC-2

(c) HBC-3

(d) HBC-4

Fig. 17. M-ฮธ relations of specimens after 0.04rad (Continued)

์†Œ์„ฑ๋ณ€ํ˜•๋Šฅ๋ ฅ์„ ๋ฐœํœ˜ํ•˜๋Š” ๊ฒƒ์œผ๋กœ ํ™•์ธ๋˜์–ด ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•

CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€๋Š” ๊ฐ•์ง„์ง€์—ญ์— ์‚ฌ์šฉ๋˜๋Š”

SMF์ ‘ํ•ฉ๋ถ€๋กœ์„œ์˜ ์‚ฌ์šฉ์ด ๊ฐ€๋Šฅํ•  ๊ฒƒ์œผ๋กœ ํŒ๋‹จ๋œ๋‹ค.

5. ๊ฒฐ ๋ก 

์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์— ๋Œ€ํ•˜

์—ฌ ๊ธฐ๋‘ฅ๊ณผ ๋ณด ํ”Œ๋žœ์ง€ ์šฉ์ ‘์œ ๋ฌด, ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „์œ ๋ฌด, ๋ณด ํ”Œ๋žœ

์ง€์™€ ๊ฐ•๊ด€์˜ ํญ๋น„๋ฅผ ๋ณ€์ˆ˜๋กœ 4๊ฐœ์˜ ์‹คํ—˜์ฒด๋ฅผ ์ œ์ž‘ํ•˜์—ฌ ๊ตฌ์กฐ

์‹คํ—˜์„ ์ˆ˜ํ–‰ํ•˜๊ณ  ๊ตฌ์กฐ๊ฑฐ๋™์„ ๋ถ„์„ํ•œ ๊ฒฐ๊ณผ ์•„๋ž˜์˜ ๊ฒฐ๋ก ์„ ์–ป

์—ˆ๋‹ค.

(1) ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๋ฐ˜

๋ณต๊ฐ€๋ ฅ ์‹คํ—˜๊ฒฐ๊ณผ ๊ธฐ๋‘ฅ๊ณผ ๋ณดํ”Œ๋žœ์ง€์˜ ์šฉ์ ‘์—†์ด ๋‹ค์ด์•„ํ”„

๋žจ๋งŒ์œผ๋กœ ๋ณดํ”Œ๋žœ์ง€์˜ ํ•˜์ค‘์„ ๊ธฐ๋‘ฅ์— ์ „๋‹ฌํ•˜๋Š” ์‹คํ—˜์ฒด์ธ

HBC-1, HBC-3 ๋ฐ HBC-4์˜ ์ตœ๋Œ€๋‚ด๋ ฅ์€ ์„ค๊ณ„ํ•˜์ค‘ ์ด

์ƒ์˜ ๋†’์€ ๋‚ด๋ ฅ์„ ๋ฐœํœ˜ํ•˜์˜€๋‹ค. ๋˜ํ•œ ๋ชจ๋“  ์‹คํ—˜์ฒด์—์„œ ๋‹ค

์ด์•„ํ”„๋žจ์ด ํŒŒ๋‹จ๋œ Step9์˜ ์ธต๊ฐ„๋ณ€์œ„๊ฐ 0.05rad์—์„œ

๊ธฐ๋‘ฅ์˜ ๋ณ€ํ˜•์€ ๋ฐœ์ƒํ•˜์ง€ ์•Š์•˜์œผ๋ฉฐ ์ ‘ํ•ฉ๋ถ€์˜ ๋ณ€ํ˜•์€ ๋Œ€๋ถ€

๋ถ„ ์™ธ๋‹ค์ด์•„ํ”„๋žจ์—์„œ ๋ฐœ์ƒํ•˜๊ฒŒ ๋˜๋ฏ€๋กœ ๊ธฐ๋‘ฅ์—๋Š” ํฐ ์˜ํ–ฅ

์ด ์—†๋Š” ๊ฒƒ์œผ๋กœ ํŒ๋‹จ๋œ๋‹ค.

(2) HBC-2๋Š” ๋ณด ํ•˜๋ถ€ ํ”Œ๋žœ์ง€์™€ ๋งž๋‹ฟ์•„ ์žˆ๋Š” ๊ฐ•๊ด€์ด ์ฝ˜ํฌ๋ฆฌ

ํŠธ ์†์— ๋ฌปํ˜€ ์žˆ๋Š” ์•ต์ปค์™€ ๋ถ„๋ฆฌ๋˜๋Š” ํŒŒ๊ดด๊ฑฐ๋™์„ ๋‚˜ํƒ€๋‚ด

๋ฉด์„œ ๋ณด์˜ ์„ค๊ณ„์ „์†Œ์„ฑ ํ•˜์ค‘์˜ 51%์˜ ์ตœ๋Œ€๋‚ด๋ ฅ์„ ๋ฐœํœ˜ํ•˜

๋Š” ๊ฒƒ์œผ๋กœ ๋‚˜ํƒ€๋‚ฌ๋‹ค.

(3) HBC-2๋ฅผ ์ œ์™ธํ•œ HBC-1, HBC-3 ๋ฐ HBC-4 ์‹คํ—˜์ฒด์—

์„œ ์•ˆ์ •์ ์ธ ํƒ„์†Œ์„ฑ ๊ฑฐ๋™์„ ๋ณด์˜€์œผ๋ฉฐ Seismic Provisions

(2005)์—์„œ ์ œ์‹œํ•œ SMF์˜ ๋ชจ๋ฉ˜ํŠธ ํšŒ์ „๊ฐ์„ฑ๋Šฅ์ธ 0.04rad

๋ฅผ ๋งŒ์กฑํ•˜๋Š” ๊ฒƒ์œผ๋กœ ๋‚˜ํƒ€๋‚ฌ๋‹ค.

๋”ฐ๋ผ์„œ, ๋ณธ ์—ฐ๊ตฌ์—์„œ ์ œ์•ˆํ•œ ์™ธ๋‹ค์ดํ”„๋žจ ์„ค๊ณ„์‹์€ SM490

โ–ก-400ร—6 ๋ฐ โ–ก-400ร—9 ๊ธฐ๋‘ฅ, SS400 H-500ร—200ร—10ร—

16 ๋ฐ H-588ร—300ร—12ร—20 ๋ณด๋ฅผ ์‚ฌ์šฉํ•œ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜• CFT

๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ์„ค๊ณ„์‹์œผ๋กœ ์‚ฌ์šฉ์ด ๊ฐ€๋Šฅํ• 

๊ฒƒ์œผ๋กœ ํŒ๋‹จ๋œ๋‹ค.

์ฐธ๊ณ ๋ฌธํ—Œ(References)

[1] ์œ ์˜์ฐฌ(1997) ์ฝ˜ํฌ๋ฆฌํŠธ์ถฉ์ „ ๊ฐํ˜•๊ฐ•๊ด€ ๊ตฌ์กฐ์˜ ๊ฑฐ๋™์— ๊ด€ํ•œ

์—ฐ๊ตฌ, ํ•œ์–‘๋Œ€ํ•™๊ต ๋Œ€ํ•™์›.

Yoo Y.C. (1997) Behavior of Concrete-Filled Square

Steel Tubular Structures, Graduate School, Hanyang

University, Korea (in Korean).

[2] ์ด์„ฑ๋„, ๊น€ํ•„์ค‘, ๊น€๊ทœ์„(2004) ๊ฐํ˜•๊ฐ•๊ด€ ๊ธฐ๋‘ฅ-Hํ˜•๊ฐ• ๋ณด์˜

์ ‘ํ•ฉ๋ถ€ ๋‚ด๋ ฅํ‰๊ฐ€ -์™ธ์ธกํ˜• ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€๋ฅผ ์ค‘์‹ฌ์œผ๋กœ-,

ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ๋…ผ๋ฌธ์ง‘, ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ, ์ œ16๊ถŒ, ์ œ1ํ˜ธ,

pp. 11-20.

Lee, S.D., Kim, P.J., and Kim, K.S. (2004) The Strength of

Square Steel Tubular Column to H-beam Connections -

Focused on the Connections with Outside-type Diaphragm -,

Journal of Korean Society of Steel Construction, KSSC,

Vol.16, No.1, pp.11-20 (in Korean).

[3] Uy, B. (2001) Local and Postlocal Buckling of Fabricated

Steel and Composite Cross Sections, Journal of Structural

Engineering, ASCE, Vol.127, No.6, pp.666-677.

[4] Matsui, C. (1985) Strength and Behavior of Frames with

Concrete Filled Square Steel Tubular Columns Under

Page 9: Structural Behavior of Welded Built-up Square CFT Column ...

์ด์„ฑํฌ๏ฝฅ ๊น€์˜ํ˜ธ๏ฝฅ ์ตœ์„ฑ๋ชจ

ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ ๋…ผ๋ฌธ์ง‘ ์ œ28๊ถŒ ์ œ2ํ˜ธ(ํ†ต๊ถŒ ์ œ141ํ˜ธ) 2016๋…„ 4์›” 83

์š” ์•ฝ : ๊ธฐ์กด ์ฝ˜ํฌ๋ฆฌํŠธ์ถฉ์ „ ๊ฐํ˜•๊ฐ•๊ด€(CFT) ๊ตฌ์กฐ์— ์‚ฌ์šฉํ•˜๋Š” ๊ฐํ˜•๊ฐ•๊ด€์€ 4๊ฐœ์˜ ํŒ์„ ์šฉ์ ‘ํ•˜์—ฌ ์ œ์ž‘ํ•˜๋Š” ๋ฐ•์Šค์นผ๋Ÿผ์ด ์ผ๋ฐ˜์ ์ด๋‹ค. ๊ทธ๋Ÿฌ๋‚˜

์ด๋Ÿฌํ•œ ๊ฐ•๊ด€์€ ์ œ์ž‘ํšจ์œจ์ด ์ €ํ•˜๋˜๋ฉฐ, ๋˜ํ•œ ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์—๋Š” ๋‚ด์ธก ๋‹ค์ด์•„ํ”„๋žจ๊ณผ ๊ด€ํ†ต ๋‹ค์ด์•„ํ”„๋žจ์„ ์šฉ์ ‘ํ•˜๋Š”๋ฐ ํŠน์ˆ˜ํ•œ ์šฉ์ ‘๊ธฐ์ˆ ์ด ํ•„์š”ํ•˜

๋‹ค. ๋”ฐ๋ผ์„œ, ์–‡์€ ๊ฐ•ํŒ์„ ์ ˆ๊ณกํ•˜๋Š” ๋ฐฉ์‹์œผ๋กœ ์‘๋ ฅ์ง‘์ค‘ ์œ„์น˜์˜ ์šฉ์ ‘์„ ํ”ผํ•˜๊ณ , ๋‹จ๋ฉดํšจ์œจ์ด ๊ทน๋Œ€ํ™”๋œ ๋‚ด๋ถ€์•ต์ปค ๋Œ์ถœํ˜•์˜ ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€์„

๊ฐœ๋ฐœํ•˜๊ฒŒ ๋˜์—ˆ๋‹ค. ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•๊ฐ•๊ด€์€ ๊ฐ•๊ด€๋‚ด๋ถ€์— ์Šคํ‹ฐํ”„๋„ˆ๊ฐ€ ์„ค์น˜๋˜์–ด ๋‚ด์ธก ๋‹ค์ด์•„ํ”„๋žจ๊ณผ ๊ด€ํ†ต ๋‹ค์ด์•„ํ”„๋žจ๊ณผ ๊ฐ„์„ญ์ด ๋ฐœ์ƒํ•˜๊ฒŒ ๋˜๋ฏ€๋กœ ๋ณธ

์—ฐ๊ตฌ์—์„œ๋Š” ์šฉ์ ‘์กฐ๋ฆฝ ๊ฐํ˜•CFT ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€๋กœ ์™ธ๋‹ค์ด์•„ํ”„๋žจํ˜•์‹์„ ์ฑ„ํƒํ•˜๊ณ  ์™ธ๋‹ค์ด์•„ํ”„๋žจ์˜ ์„ค๊ณ„์‹์„ ์ œ์•ˆํ•˜์˜€์œผ๋ฉฐ, ๊ธฐ๋‘ฅ-๋ณด ์ ‘ํ•ฉ๋ถ€์˜

๊ฑฐ๋™์„ ํŒŒ์•…ํ•˜๊ธฐ ์œ„ํ•ด ์‹ค๋Œ€ํ˜• 4๊ฐœ ์‹คํ—˜์ฒด๋ฅผ ์ œ์ž‘ํ•˜์—ฌ ๊ตฌ์กฐ๊ฑฐ๋™ ๋ฐ ๋‚ด๋ ฅ์„ ๋ถ„์„ํ•˜์˜€๋‹ค.

ํ•ต์‹ฌ์šฉ์–ด : ์ฝ˜ํฌ๋ฆฌํŠธ ์ถฉ์ „๊ฐ•๊ด€, ๋ƒ‰๊ฐ„์„ฑํ˜•, ์Šคํ‹ฐํ”„๋„ˆ, ๋ณด๊ธฐ๋‘ฅ, ํญ๋‘๊ป˜๋น„

Earthquake Loading, Proceedings of International Specialty

Conference on Concrete Filled Steel Tubular Structures,

Harbin, pp. 104-111.

[5] Liang, Q.Q., Uy, B., and Liew, J.Y.R. (2006) Nonlinear

Analysis of Concrete-Filled Thin-Walled Steel Box

Columns with Local Buckling Effects, Journal of

Constructural Steel Research, Vol.62, No.6, pp.581-591.

[6] Liang, Q.Q., Uy, B., and Liew, J.Y.R. (2007) Local

Buckling of Steel Plates in Concrete-Filled Thin-Walled

steel tubular beam-columns, Journal of Constructional

Steel Research, Vol.63, pp.396-405.

[7] Tao, Z., Han, L.H., and Wang, Z.B. (2005) Experimental

Behaviour of Stiffened Concrete-Filled Thin-Walled

Hollow Steel Structural (HSS) Stub Columns, Journal of

Constructional Steel Research, Vol.61, pp.962-983.

[8] ์ด์„ฑํฌ, ์ •ํ—Œ๋ชจ, ๊น€๋Œ€์ค‘, ๊น€์ง„ํ˜ธ, ์ตœ์„ฑ๋ชจ(2008) ์šฉ์ ‘์กฐ๋ฆฝ

๊ฐํ˜• CFT ๊ธฐ๋‘ฅ-๋ณด ์™ธ๋‹ค์ด์•„ํ”„๋žจ ์ ‘ํ•ฉ๋ถ€์˜ ๊ตฌ์กฐํŠน์„ฑ, ํ•œ๊ตญ

๊ฐ•๊ตฌ์กฐํ•™ํšŒ๋…ผ๋ฌธ์ง‘, ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ, ์ œ20๊ถŒ, ์ œ6ํ˜ธ, pp.

711-722.

Lee, S.H., Jung, H.M., Kim, D.J., Kim, J.H., and Choi,

S.M. (2008) Structural Characteristics of Welded Built-up

Square CFT Column to Beam Connections with External

Diaphragm, Journal of Korean Society of Steel

Construction, KSSC, Vol.20, No.6, pp.711-722 (in

Korean).

[9] ์ด์„ฑํฌ, ์ตœ์˜ํ™˜, ์—ผ๊ฒฝ์ˆ˜, ๊น€์ง„ํ˜ธ, ์ตœ์„ฑ๋ชจ(2008) ์šฉ์ ‘์กฐ๋ฆฝ

๊ฐํ˜• CFT ๋‹จ์ฃผ์˜ ๊ตฌ์กฐํŠน์„ฑ์— ๊ด€ํ•œ ์‹คํ—˜์  ์—ฐ๊ตฌ, ํ•œ๊ตญ๊ฐ•๊ตฌ

์กฐํ•™ํšŒ๋…ผ๋ฌธ์ง‘, ํ•œ๊ตญ๊ฐ•๊ตฌ์กฐํ•™ํšŒ, ์ œ20๊ถŒ, ์ œ5ํ˜ธ, pp. 645-653.

Lee, S.H., Choi, Y.H., Yeom, K.S., Kim, J.H., and Choi,

S.M. (2008) An Experimental Study on Structural Perfor-

mance of Welded Built-up Square CFT Stub Columns,

Journal of Korean Society of Steel Construction, KSSC,

Vol.20, No.5, pp.645-653 (in Korean).

[10] Lee, S.H., Yang, I.S., and Choi, S.M.(2010) Structural

Characteristics of Welded Built-Up Square CFT

Column-To-Beam Connections with External Diaphragms,

Steel and Composite Structures, SCS, Vol.10, No.3,

pp.261-279.

[11] ๋Œ€ํ•œ๊ฑด์ถ•ํ•™ํšŒ(2004) ์ฝ˜ํฌ๋ฆฌํŠธ์ถฉ์ „ ๊ฐ•๊ด€๊ตฌ์กฐ ์„ค๊ณ„ ๋ฐ ์‹œ๊ณต

๋งค๋‰ด์–ผ, ๋Œ€ํ•œ๊ฑด์ถ•ํ•™ํšŒ.

AIK.(2004) Manual on Design and Construction of

Concrete Filled Steel Tube Structures, AIK, Korea (in

Korean)

[12] AIJ(1997) Recommendations for Design and Construction

of Concrete Filled Steel Tubular Structures, AIJ (in

Japanese).

[13] AISC(2002) Seismic Provisions for Structural Steel

Buildings, AISC.