8
© Telect, Inc., All Rights Reserved, 3.1.12/rev.2 1.509.926.6000 :: telect.com 1 T1 Backhaul Connectivity Solution All Products :: Application Note Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments Communications service providers performing backhaul of T1 circuits from remote sites to COs, head ends or MTSOs Requirement for cost-effective demarcation, circuit testing, troubleshooting and maintenance The Solution: Telect’s 1 RU Customer Interface Panel (CIP) Telect’s CIP incorporates RJ48X interface ports, which passively loop back the T1 circuit when an RJ cable is not connected in the corresponding port. This enables the testing of the circuit from the NOC or head end to the Telect CIP and back. Using the loopback feature, the provider can perform pre-service testing before turning up the circuit. For simple, remote troubleshooting, the technician can remove the plug from the appropriate RJ jack, which will isolate the location of the problem to either transport or local. When connected to a DSX-1 panel, the provider can monitor both directions of the signal. All of this functionality is available in a 1 RU panel to help maximize limited space in remote applications. Deploy your T1 network element, and Telect provides all additional components required for the total solution (see pages 3-7). Customer Interface Panel: Telect part number 097-0128-0006 (with loopback functionality) or 097-0128-0007 (without loopback functionality).
Transcript
Page 1: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

1

T1 Backhaul Connectivity SolutionAll Products :: Application Note

Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node

The Application: T1 Demarcation and Testing in Backhaul Environments• Communications service providers performing backhaul of T1 circuits from remote sites to COs, head ends or MTSOs

• Requirement for cost-effective demarcation, circuit testing, troubleshooting and maintenance

The Solution: Telect’s 1 RU Customer Interface Panel (CIP)

Telect’sCIPincorporatesRJ48Xinterfaceports,whichpassivelyloopbacktheT1circuitwhenanRJcableisnotconnectedinthe corresponding port. This enables the testing of the circuit from the NOC or head end to the Telect CIP and back. Using the loopback feature, the provider can perform pre-service testing before turning up the circuit. For simple, remote troubleshooting, the technician canremovetheplugfromtheappropriateRJjack,whichwillisolatethelocationoftheproblemtoeithertransportorlocal.When connectedtoaDSX-1panel,theprovidercanmonitorbothdirectionsofthesignal.Allofthisfunctionalityisavailableina1RUpanel tohelpmaximizelimitedspaceinremoteapplications.DeployyourT1networkelement,andTelectprovidesalladditionalcomponentsrequired for the total solution (see pages 3-7).

CustomerInterfacePanel:Telectpartnumber097-0128-0006(withloopbackfunctionality)or097-0128-0007(withoutloopbackfunctionality).

Page 2: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

2

T1 Backhaul Connectivity SolutionAll Products :: Application Note

T1 Demarcation, Testing and Troubleshooting at the Backhaul Node

CIP Capabilities: Circuit Demarcation, Testing & Troubleshooting

28 RJ48X Interface Ports

• Simple connection to SONET/node device

• RJ48Xjacksenableremotetroubleshootingwithpassiveloopbackcapabilities(Telectpartnumber097-0128-0006)

• RJ48Cjacksavailableifloopbackfunctionalitynotrequired(097-0128-0007)

28 DS1 Ports

• Enables active monitoring at site

Frontview

64-Pin AMP Connectors

• Availableforfasterin-fieldconnections

• Includescrewlocksandcableties

• CompatiblewithT1nodedevicecabling

Wire-Wrap I/O Field

• Fortraditionalwire-wrapconnections

• Toprow—1-28transmit

• Bottomrow—1-28receive

19” or 23” mounting

Rearview

64-pinconnector:Circuits1-28—transmit

64-pinconnector:Circuits1-28—receive

Page 3: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

3

T1 Backhaul Connectivity SolutionAll Products :: Application Note

Application, Products and Parts

Remote Site EnclosureCore Connectivity Components

1. Customer Interface Panel (CIP): Enables demarcation and remote testing of circuits.

2. RUMultifunctionalPanel:Fiberopticandcopperconnectivityplatform that occupies minimal space.

3. GMTFusePanel:Providespowerdistributionandprotectionfor equipment in the enclosure.

4. RemoteSiteEnclosure:Durable,flexiblehousingsolutionforall equipment.

5. DCPower/RectifierSystem:RectifierandsystemcontrollerforsupplyingACpowerfeedtotheenclosure.

6. Fiber Optic, DS1 and/or DS3 Patch Cords: Required for connecting additional equipment in enclosure.

7. RJ48PatchCords:Forconnectionofcustomerinterfacepanel and radio/remote terminal equipment.

Page 4: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

4

T1 Backhaul Connectivity SolutionAll Products :: Application Note

1. T1/DS1 Customer Interface Panels

Features

• High-densitydemarcation/testingsolution

• RJ48Xjacksprovideautomaticloopbackcapabilities

• RJPortsmeetallkeystandards

• DS1/Bantamjacksprovideanon-intrusiveplatformfor circuit monitoring

• 64-pinfemaleconnectorsenablerapiddeploymentandsimple usage

• Completelyenclosedchassisprovidesrobustprotection for connections

Ordering Information

28-term.,RJ48Xjacks,withloopbackfunctionality 097-0128-000628-term.,RJ48Cjacks,noloopbackfunctionality 097-0128-0007

Specifications

Dimensions 19”Wx1.7”Hx5.9”D483mmx43mmx150mm

Weight 10lbs.(4.5kg)Material SteelTotal terminations 28RJ48,28DS1

RJ48X Schematic

Shorting bars(short removed oninsertion of plug)

RJ48Xjacksfeatureashortingbarbetweentransmitandreceivepinstoenableautomaticloopbackwhennopatchcordisinserted.RJ48Cjacksdonotincorporateshortingbars.

Page 5: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

5

T1 Backhaul Connectivity SolutionAll Products :: Application Note

2. 1 RU Modular Multifunction Panel

Features

• Deploywithfiberopticpatch/splicemoduleforterminationofincoming cable and connection to node device

• DSX-1,DSX-3andEthernetmodulesfitinthesamechassistomaximizespaceandenableversatileconnectivity

• 1 RU chassis accommodates 3 modules

• Choosemodulesasrequiredtofitthespecificrequirementsof the application

Ordering Information

Chassis,3modulecapacity ELF-0000-240012-portfiberpatch/splice ELF-SP12-SCPT8-term.DSX-1module ELF-1008-12001-term.DSX-3module ELF-3206-120016-term.RJ-RJpatchmodule ELF-9716-1900Additional module options are available. See Telect.com.

Specifications

ChassisDimensions 19”Wx1.75”Hx5”D

483mmx44mmx127mmWeight 5 lbs. (2.3 kg)Material SteelAgencycompliance(system) NEBS, ITU-TFiber Optic Patch/Splice ModuleDimensions 5.9”Wx1.7”Hx8”D

150mmx42mmx202mmWeight 2 lbs. (0.9 kg)Total terminations 12 patch, 12 splicePatch adapters SC/UPCDSX-1ModuleDimensions 6”Wx1.6”Hx5.5”D

152mmx42mmx140mmWeight 2.5 lbs. (1.1 kg)Total terminations 8Circuit access Front cross-connectCross-connectfield Wire-wrapNetworkelementfield BNCDSX-3ModuleDimensions 6”Wx1.6”Hx5”D

152mmx42mmx140mmWeight 2 lbs. (0.9 kg)Total terminations 2Circuit access Rear cross-connectCross-connectfield BNC connectorizedNetworkelementfield BNCEthernet ModuleDimensions 5.8”Wx1.6”Hx5”D

149mmx41mmx127mmWeight 2 lbs. (0.91 kg)Total terminations 16Circuit access Front cross-connectCross-connectfield RJ45CNetworkelementfield RJ45C

Page 6: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

6

T1 Backhaul Connectivity SolutionAll Products :: Application Note

3. Universal Voltage GMT Panels, ±24V/-48V

Features

• Essentialpowerdistributionsolutionfornodeequipment

• Universaloperatingvoltagehandles±24Vor-48V applicationsseamlessly

• Bayalarmstandardformajor/minoralarms

• Dual 100A input; up to 20A per GMT output

• Designed for UL and NEBS compliance

Ordering Information

Dual-feed10/10-position,white HPGMT10Dual-feed 10/10-position, black HPGMT10-BLKDual-feed15/15-position,white HPGMT15Dual-feed 15/15-position, black HPGMT15-BLKSingle-feed20-position,white HPGMT20SSingle-feed 20-position, black HPGMT20S-BLKSingle-feed30-position,white HPGMT30SSingle-feed 30-position, black HPGMT30S-BLK

Additionalconfigurationsareavailable.SeeTelect.com.

Specifications

ElectricalNominal voltage ±24to-48VDCInput rating 100AMaximum inputinterrupt device

125A

Maximum outputprotection device

20A

Powerdissipation(fullload) 12WperbusMechanicalDimensions 17”Wx1.72”Hx12”D

432mmx44mmx305mmWeight 9lbs.(4.1kg)Material Cold-rolled steelFinish PowdercoatMounting 19” or 23”EnvironmentalTemperature -5° to 55° CHumidity 0 to 90%,non-condensingConnectionsInput terminals Dualstud,1/4”on5/8”centersOutput terminals Screwterminal,#6Chassis ground Dualstud,#10on5/8”centersAlarmsAlarm indicators Power,fuse,bayalarmAlarmtype Form CAlarm connector 0.045”squarepinRelaycontactratings 0.6Aat48VDC;1Aat120

VACComplianceAgency NEBS 3, UL, CUL, CE

Page 7: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

7

T1 Backhaul Connectivity SolutionAll Products :: Application Note

4. Outdoor Enclosures

Features

• Broadrangeofconfigurationsavailable

• Engineeredasstandalonecabinetsorasfullyintegratedsolu-tionswithequipmentpre-installed

• Modular component-based design enables extensive customizationtofitthespecificsoftheapplication

• Engineered,constructedandbuiltatTelect’scentrallylocatedfacilitytoexpeditedeliveryanddeployment

• Standardsizeslistedbelow:contactTelectforoptions,specsand ordering information

Ordering Information

TME45RUenhancedseismicmodularenclosureTMEstandardmodularenclosures(40RU,32RU,24RU)TWE25RUwall-mount/pad-mountenclosureAdditionalconfigurationsareavailable.SeeTelect.com.

5. DC Power Systems

Chooseindividualrectifierandsystemcontrollercomponents,orfullyintegratedpowersystemsthatfeatureahigh-density design and can be pre-installed in a Telect enclosure for immediatedeployment.

Ordering Information

Configurablerectifiersystemcaninclude:• 48V/1800Wor48V/900Wrectifiers

• Systemcontroller

• I/O board

ContactTelectfordetailedspecificationsandorderinginformation.

TelectTWE25RUenclosure.

6. & 7. Patch Cords

RequiredforconnectionsbetweenCIP,nodedeviceandmultifunctionpanelwithintheenclosure.

DS1/Bantam Patch CordsDS1/Bantam, 3 ft. 040-1000-003DS1/Bantam, 5 ft. 040-1000-005DS3/Coax Patch CordsDS3/Coax, 3 ft. 043-0922-003DS3/Coax, 6 ft. 043-0922-006Fiber Optic Patch CordsSC/UPCSMfiber,1m F12-SSG-M001-0SC/UPCSMfiber,3m F12-SSG-M003-0RJ Patch Cords, Crossover Wiring Scheme2-pairRJpatchcord,3ft. 902-23DD-0016-0032-pairRJpatchcord,5ft. 902-23DD-0016-005RJ Patch Cords, Standard Wiring Scheme2-pairRJpatchcord,3ft. 902-23DD-0004-0032-pairRJpatchcord,5ft. 902-23DD-0004-005

Page 8: T1 Backhaul Connectivity Solution - Telect · T1 Backhaul Connectivity Solution ... , which will isolate the location of the problem to either transport or ... Use this table to create

© Telect, Inc., All Rights Reserved, 3.1.12/rev.21.509.926.6000 :: telect.com

8

T1 Backhaul Connectivity SolutionAll Products :: Application Note

Build a Solution

Use this table to create a list of part numbers required for your solution.Quantity Description Part Number


Recommended