Below is a flowchart describing 40 CFR Part 60, Subpart KKKK. It will likely not be accessible using a screen reader. For the text of the statute/rule, please go to 40 CFR Part 60, Subpart KKKK (1 of 29) Start Do you own or operate an affected source that was constructed, modified or reconstructed after 02/18/2005? Does your stationary combustion turbine have a heat input at peak load equal to or greater than 10.7 gigajoules (10 MMBtu) per hour? §60.4300 §60.4305(a) Yes No No Yes Is the combustion turbine at an integrated gasification combined cycle electric utility steam generating unit subject to subpart Da of this part? §60.4310(c) 3 40 CFR Part 60, Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion turbine? §60.4320(a) No §60.4320(a) Is the output-based standard being used? 1 2 Yes NOx No 08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009 The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
Transcript
Page 1: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

Below is a flowchart describing 40 CFR Part 60, Subpart KKKK. It will likely not be accessible using a screen reader. For the text of the statute/rule, please go to

40 CFR Part 60, Subpart KKKK(1 of 29)

Start

Do you own or operate an affected

source that was constructed, modified or reconstructed after

02/18/2005?

Does your stationary

combustion turbine have a heat input at peak load equal to or

greater than 10.7 gigajoules (10 MMBtu) per

hour?

§60.4300

§60.4305(a)

Yes

No

NoYes

Is thecombustion turbine

at an integrated gasificationcombined cycle electric utility steam

generating unit subject tosubpart Da of this

part?

§60.4310(c)

3

40 CFR Part 60, Subpart KKKK does not apply

End

No

Yes

Yes

Is the affected source a heat recovery unit operating independent of the stationary

combustion turbine?

§60.4320(a)

No

§60.4320(a)

Is the output-based

standard being used?

12

Yes

NOx

No

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 2: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(2 of 29)

3

Are you operating an

emergency combustionturbine?

Yes

No

§60.4310(a)

Is your stationarycombustion turbine engaged

in research and development of equipment for both combustion turbine

emission control techniques andcombustion turbine efficiency

improvements?

§60.4310(b)No

4

Yes

Comply with the following:Standard

§60.4310(a)§60.4333(a)§60.4390(a)Reporting

§60.4390(a)

Comply with the following:Standard

§60.4310(b)§60.4333(a)§60.4390(b)Reporting

§60.4390(b)

30

Is theoperation a test

cell/stand?

§60.4310(d)No

40 CFR Part 60, Subpart KKKK does not apply

Yes End

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 3: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(3 of 29)

4 NOx

§60.4320(a)

Isthe output < 30

MW?

§60.4320(a)

20

5

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4333(a)Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Yes

Is the output-based

standard being used?

§60.4320(a)

6

Yes

22

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4333(a)Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

No

No

Yes

Are you operating aturbine that operates at < 75 percentof peak load or a turbine operating at

temperatures < 0 °F?

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 4: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(4 of 29)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4333(a)Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Is the output-based

standard being used?

§60.4320(a)

Yes

6

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4333(a)Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

21

No

38

20

39

22

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 5: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(5 of 29)

Is the turbineheat input at peak load

> 850 MMBtu/h?

Does the turbine fire only gaseous fuels

and > 50% of heat input is from natural gas?

5

Is the turbine heat input at peak load > 50

MMBtu/h?

7

8

No

13

No

Yes

Yes

Yes

No

§60.4320(a)

§60.4320(a)

§60.4320(a)

§60.4320(a)

No

Does the turbine fire only gaseous fuels and> 50% of heat input is from

natural gas?

Is the output-based

standard being used?

§60.4320(a)

Yes

Yes

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

18

17

No

22

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 6: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(6 of 29)

§60.4320(a)

§60.4320(a)

Was the turbine constructed after

02/18/2005?

Was the turbine constructed after

02/18/2005?

8

7

No

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Is the output-based

standard being used?

§60.4320(a)

9

No

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

10

Is the output-based

standard being used?

§60.4320(a)

11

No

Yes

No

12

Yes

Yes

Yes

22

22

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 7: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

Is the output-based

standard being used?

§60.4320(a)

Yes

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

18

17

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

No

22

20

40 CFR Part 60, Subpart KKKK(7 of 29)

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 8: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(8 of 29)

Is the output-based

standard being used?

§60.4320(a)

Yes

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

10

9

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

No

22

20

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 9: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

Is the output-based

standard being used?

§60.4320(a)

Yes

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

12

11

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

No

22

20

40 CFR Part 60, Subpart KKKK(9 of 29)

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 10: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(10 of 29)

Was the turbine constructed after

02/18/2005?

§60.4320(a)

13

Is the turbineused for electric

generation?

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

15

Does the turbine fire only gaseous fuels and> 50% of heat input is from

natural gas?

§60.4320(a)

Yes

§60.4320(a)

No

Yes

16

No

Is the output-based

standard being used?

§60.4320(a)

Yes

Yes

21

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

No

14

No

20

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 11: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(11 of 29)

Is the output-based

standard being used?

§60.4320(a)

Yes

NoComply with the following:

Standard§60.4320(a)-Table 1

§60.4320(a)-(b)§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

16

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4333(a)Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Is the output-based

standard being used?

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

No

Yes

23

§60.4320(a)

14

22

20

20

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 12: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(12 of 29)

15

Is the turbineused for electric

generating?

§60.4320(a)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Is the output-based

standard being used?

§60.4320(a)

Yes

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Is the output-based

standard being used?

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Comply with the following:Standard

§60.4320(a)-Table 1§60.4320(a)-(b)

§60.4325§60.4333(a)

Monitoring/Testing[T][G]§60.4400(a)

[T]§60.4400(b), [T](b)(1), [T](b)(4)[T]§60.4400(b)(6)

Yes

No

No

No

Yes

§60.4320(a)

20

20

21

23

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 13: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(13 of 29)

20

Are NOxemissions controlledusing water or steam

injection?

§60.4335(a)

Is a CMS used to monitor

fuel consumption and water/steam to fuel

ratio?

Yes

Comply with the following:Standard

§60.4335(a)Monitoring/Testing

§60.4335(a)[G]§60.4355(a)

[T]§60.4400(b)(3)Recordkeeping

§60.4335(a)[G]§60.4355(a)

Reporting§60.4375(a)

§60.4380, [G](a)§60.4395

25

§60.4335(a)

Is heatrecovered from

the turbine?

§60.4350(f)(2)

26Yes

No

Comply with the following:Standard

§60.4335(b)(1)[G]§60.4345

Monitoring/Testing§60.4335(b)(1)[G]§60.4345

§60.4350(a)-(f)[T]§60.4400(b)(5)[T][G]§60.4405Recordkeeping

[G]§60.4345§60.4350(b)Reporting

[G]§60.4345§60.4350(d)§60.4375(a)

§60.4380, [G](b)§60.4395

Yes

No

Is aNOx CEMS

used?

27

No

Yes

No

§60.4335(b),§60.4340(b)

30

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 14: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(14 of 29)

21

Are NOxemissions controlledusing water or steam

injection?

§60.4335(a)

Is a CMS used to monitor

fuel consumption and water/steam to fuel

ratio?

Yes

Comply with the following:Standard

§60.4335(a)Monitoring/Testing

§60.4335(a)[G]§60.4355(a)

[T]§60.4400(b)(3)Recordkeeping

§60.4335(a)[G]§60.4355(a)

Reporting§60.4375(a)

§60.4380, [G](a)§60.4395

28

§60.4335(a)

Is heatrecovered from

the turbine?

§60.4350(f)(2)

Yes

No

Comply with the following:Standard

§60.4335(b)(1)[G]§60.4345

Monitoring/Testing§60.4335(b)(1)[G]§60.4345

§60.4350(a)-(f)[T]§60.4400(b)(5)[T][G]§60.4405Recordkeeping

[G]§60.4345§60.4350(b)Reporting

[G]§60.4345§60.4350(d)§60.4375(a)

§60.4380, [G](b)§60.4395

Yes

No

Is aNOx CEMS

used?

No

No

30

26

§60.4335(b),§60.4340(b)

27

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 15: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(15 of 29)

22

Are NOxemissions controlledusing water or steam

injection?

§60.4335(a)

Is a CMS used to monitor

fuel consumption and water/steam to fuel

ratio? Yes

Comply with the following:Standard

§60.4335(a)Monitoring/Testing

§60.4335(a)[G]§60.4355(a)

[T]§60.4400(b)(3)Recordkeeping

§60.4335(a)[G]§60.4355(a)

Reporting§60.4375(a)

§60.4380, [G](a)§60.4395

§60.4335(a)

Is heatrecovered from

the turbine?

§60.4350(f)(2)No

Comply with the following:Standard

§60.4335(b)(1)[G]§60.4345

Monitoring/Testing§60.4335(b)(1)[G]§60.4345

§60.4350(a)-(f)[T]§60.4400(b)(5)[T][G]§60.4405Recordkeeping

[G]§60.4345§60.4350(b)Reporting

[G]§60.4345§60.4350(d)§60.4375(a)

§60.4380, [G](b)§60.4395

Yes

No

Is aNOx CEMS

used?

No

Yes

No

Is the turbine for mechanical drive

applications?29Yes

Yes

No

30 26

27

§60.4335(b),§60.4340(b)

§60.4350(f)(3)

28

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 16: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(16 of 29)

23

Are NOxemissions controlledusing water or steam

injection?

§60.4335(a)

Is a CMS used to monitor

fuel consumption and water/steam to

fuel ratio?

Yes

Comply with the following:Standard

§60.4335(a)Monitoring/Testing

§60.4335(a)[G]§60.4355(a)

[T]§60.4400(b)(3)Recordkeeping

§60.4335(a)[G]§60.4355(a)

Reporting§60.4375(a)

§60.4380, [G](a)§60.4395

§60.4335(a)

Is heatrecovered from

the turbine?

§60.4350(f)(2)

Yes

No

Comply with the following:Standard

§60.4335(b)(1)[G]§60.4345

Monitoring/Testing§60.4335(b)(1)[G]§60.4345

§60.4350(a)-(f)[T]§60.4400(b)(5)[T][G]§60.4405Recordkeeping

[G]§60.4345§60.4350(b)Reporting

[G]§60.4345§60.4350(d)

§60.4380, [G](b)§60.4395

Yes

No

Is aNOx CEMS

used?§60.4335(b),§60.4340(b)

No

Yes

No

30

26

27

29

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 17: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(17 of 29)

Is combined gross energy output

apportioned?

§60.4333(b)(2)

Comply with the following:Standard

§60.4333(b)(1)Monitoring/Testing

§60.4333(b)(1)

Comply with the following:Standard

§60.4333(b)(2)Reporting

§60.4333(b)(2)

Comply with the following:Monitoring/Testing[T]§60.4400(b)(2)

Yes

Is aduct burner

used?

Does the affected unit utilize

a common steam header with one or more combustion

turbines? §60.4333(b)

26

Yes

§60.4400(b)(2)

Yes

No

No

No

30

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 18: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(18 of 29)

25

Is the affected unit combined heat

and power?

§60.4335(b)(4)

Comply with the following:Monitoring/Testing[T]§60.4400(b)(2)

Is the affected unit

combined cycle? §60.4350(f)(2)

Does the affected unit utilize a

common steam header with one or more combustion

turbines?

§60.4333(b)

Is combined gross energy output

apportioned?

§60.4333(b)(2)

Comply with the following:Standard

§60.4333(b)(2)Reporting

§60.4333(b)(2)

Comply with the following:Standard

§60.4333(b)(1)Monitoring/Testing

§60.4333(b)(1)

Comply with the following:Monitoring/Testing

§60.4350(g)

Is aduct burner

used?

§60.4400(b)(2)

Yes

Yes

No

No

Comply with the following:Monitoring/Testing

§60.4350(h)

No

No

30

30

30

Yes

YesYes

No

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 19: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(19 of 29)

Comply with the following:

Monitoring/Testing[T]§60.4400(b)(2)

Is the affected unit

combined cycle?

§60.4350(f)(2)

Doesthe affected unit utilize

a common steam header with one or more combustion

turbines?

§60.4333(b)

Is combined gross energy output

apportioned?

§60.4333(b)(2)

Comply with the following:Standard

§60.4333(b)(2)Reporting

§60.4333(b)(2)

Comply with the following:Standard

§60.4333(b)(1)Monitoring/Testing

§60.4333(b)(1)

Comply with the following:Monitoring/Testing§60.4350(f)(1), (g)

Is aduct burner

used? §60.4400(b)(2)

28

Comply with the following:Standard

§60.4335(b)(2), (b)(3)Monitoring/Testing§60.4335(b)(2), (b)(3)

Is the affected unit combined heat

and power?

§60.4335(b)(4)

No

Comply with the following:Standard

§60.4335(b)(4)Monitoring/Testing

§60.4335(b)(4)§60.4350(f)(2), (h)

Yes

Yes

Yes

No

No

No

Yes

No

Comply with the following:Monitoring/Testing§60.4350(f)(2), (h)

Yes

30

30

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 20: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(20 of 29)

Comply with the following:Monitoring/Testing[T]§60.4400(b)(2)

Is the affected unit

combined cycle?

§60.4350(f)(2)

Doesthe affected unit utilize

a common steam header with one or more combustion

turbines?

§60.4333(b)

Is combined gross energy output

apportioned?

§60.4333(b)(2)

Comply with the following:Standard

§60.4333(b)(2)Reporting

§60.4333(b)(2)

Comply with the following:Standard

§60.4333(b)(1)Monitoring/Testing

§60.4333(b)(1)

Comply with the following:Monitoring/Testing§60.4350(f)(1), (g)

Is aduct burner

used? §60.4400(b)(2)

29

Comply with the following:Standard

§60.4335(b)(2), (b)(3)Monitoring/Testing§60.4335(b)(2), (b)(3)

§60.4350(f)(3)

Is the affected unit combined heat

and power?

§60.4335(b)(4)

Comply with the following:Standard

§60.4335(b)(4)Monitoring/Testing

§60.4335(b)(4)§60.4350(f)(2), (h)

Yes

Yes

Yes

No

No

Yes

No

Comply with the following:Monitoring/Testing§60.4350(f)(2), (h)

Yes

30

30

No

No

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 21: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(21 of 29)

Comply with the following:Monitoring/Testing

[T]§60.4340(a)Reporting

§60.4375(b)

Is the unit regulated under

Part 75 and monitoring using methodology under

Appendix E to Part 75?

Comply with the following:Monitoring/Testing§60.4340(b)(2)(i)-(iii)

[G]§60.4355(a)[T]§60.4410

Recordkeeping[G]§60.4355(a)

[T]§60.4410Reporting

§60.4375(a)§60.4380, [G](c)

§60.4395

Comply with the following:Monitoring/Testing§60.4340(b)(2)(iv)

§60.4355(b)[T]§60.4410

Recordkeeping§60.4355(b)[T]§60.4410Reporting

§60.4375(a)§60.4380, [G](c)

§60.4395No

§60.4340(b)(2)(iv)

Yes

Are annualcompliance tests used to show continuous

compliance?

§60.4340(a)

Yes

27

No

30

30

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 22: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(22 of 29)

Comply with the following:Monitoring/Testing

[T]§60.4340(a)Reporting

§60.4375(b)

38

NoIs a

NOx CEMSused?

Yes

§60.4335(b),§60.4340(b)

Comply with the following:Standard

§60.4335(b)(1)[G]§60.4345

Monitoring/Testing§60.4335(b)(1)[G]§60.4345

§60.4350(a)-(c), (e)-(f), (h)[T]§60.4400(b)(5)[T][G]§60.4405Recordkeeping

[G]§60.4345§60.4350(b)Reporting

[G]§60.4345§60.4375(a)

§60.4380, [G](b)§60.4395

30

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 23: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(23 of 29)

Comply with the following:Monitoring/Testing

[T]§60.4340(a)Reporting

§60.4375(b)

39

NoIs a

NOx CEMSused?

Yes

§60.4335(b),§60.4340(b)

Comply with the following:Standard

§60.4335(b)(1)[G]§60.4345

Monitoring/Testing§60.4335(b)(1)[G]§60.4345

§60.4350(a)-(c), (e)-(f), (h)[T]§60.4400(b)(5)[T][G]§60.4405Recordkeeping

[G]§60.4345§60.4350(b)Reporting

[G]§60.4345§60.4375(a)

§60.4380, [G](b)§60.4395

Is the turbine for mechanical drive

applications?

Yes

NoComply with the following:

Monitoring/Testing§60.4350(f)(2)

Comply with the following:Monitoring/Testing

§60.4350(f)(3)30

§60.4350(f)(3)

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 24: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(24 of 29)

30 SO2

§60.4330(b)

Is the turbine located in a noncontinental area or in a

continental area for which the Administrator has determined does not have access to natural gas

and that the removal of sulfur compounds would do more environmental

harm than benefit?

36

Yes

Is the output based standard

being used?

No

Comply with the following:Standard

§60.4330(b)(1)§60.4333(a)[G]§60.4385

Monitoring/Testing§60.4415(a)

Comply with the following:Standard

§60.4330(b)(2)§60.4333(a)

Monitoring/Testing§60.4415(a)

Yes

§60.4330(b)(1)

35

32

No

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 25: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(25 of 29)

36

Is the turbine burning

at least 50% biogas on a calendar

basis?

37No

Yes

Comply with the following:Standard

§60.4330(a)(3)§60.4333(a)[G]§60.4385

Monitoring/Testing§60.4415(a)

32

§60.4330(a)(3)

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 26: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(26 of 29)

37 SO2

Is the output based standard

being used?

32

§60.4330(a)(2)

Is the fuel demonstrated not to exceed the emission

limitation?§60.4365

Comply with the following:Standard

§60.4330(a)(2)§60.4333(a)

Monitoring/Testing§60.4415(a)

Comply with the following:Standard

§60.4330(a)(1)§60.4333(a)[G]§60.4385

Monitoring/Testing§60.4415(a)

Comply with the following:Monitoring/Testing

§60.4365, (b)Recordkeeping

§60.4365(b)

Comply with the following:Monitoring/Testing

§60.4365, (a)Recordkeeping

§60.4365(a)

Is representative fuel sampling used for

demonstration?

§60.4365(b)

Is sulfur content of the fuel periodically

determined?

§60.4415(a)(1)

31

Yes

NoIs SO diluent gas

2

monitoring used for the performance test?

§60.4415(a)(3)

Comply with the following:Monitoring/Testing

[T]§60.4415(a)(3)

Yes

Comply with the following:Monitoring/Testing

[T]§60.4415(a)(2)

No

End

No

Yes

Comply with the following:Standard

[G]§60.4385

No

Yes

No

35

Yes

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 27: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(27 of 29)

31

Is gaseous fuel used?

Is liquid fuel used?

Comply with the following:Monitoring/Testing[T]§60.4415(a)(1)(ii)

Comply with the following:Monitoring/Testing[T]§60.4415(a)(1)(i)

Yes

Yes

End

§60.4415(a)(1)(ii)

§60.4415(a)(1)(i)

§60.4415(a)(1)

Is liquid fuel used?

§60.4415(a)(1)(i)

34

Comply with the following:Monitoring/Testing

[T]§60.4370(a)[T]§60.4415(a)(1)(i)

Is gaseous fuel used?

§60.4415(a)(1)(ii)

Comply with the following:Monitoring/Testing[T]§60.4415(a)(1)(ii)

Is sulfur content of the fuel periodically

determined?

33

No

Yes

No

Yes

End

Comply with the following:Monitoring/Testing

[T]§60.4415(a)(1)Reporting

§60.4375(a)

Comply with the following:Monitoring/Testing

§65.4360[T]§60.4415(a)(1)

Reporting§60.4375(a)

No

No

No

Yes

32

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 28: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(28 of 29)

End

Is SO diluent gas 2

monitoring used for the performance test?

§60.4415(a)(3)

Comply with the following:Monitoring/Testing

[T]§60.4415(a)(3)

Yes

Comply with the following:Monitoring/Testing

[T]§60.4415(a)(2)

Is liquid fuel used?

§60.4370(a)

33

No

No

No

Comply with the following:Monitoring/Testing

§60.4370(a)

§60.4370(b)

Yes34Is gaseous fuel used?

Yes

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 29: TCEQ - 40 CFR Part 60, Subpart KKKK; Flowchart · Subpart KKKK does not apply End No Yes Yes Is the affected source a heat recovery unit operating independent of the stationary combustion

40 CFR Part 60, Subpart KKKK(29 of 29)

Is fuel supplied with

intermediate bulk storage?

§60.4370(b)

Is a custom fuel monitoring schedule used?

§60.4370(c)

End

Comply with the following:Monitoring/Testing

§60.4370(b)Recordkeeping

§60.4370(b)

Is the720-hour fuel

sampling in Appendix D to Part 75

used? §60.4370(c)(2)

Yes

Comply with the following:Monitoring/Testing§60.4370(c), [G](c)(2)

Recordkeeping§60.4370(c)Reporting

§60.4370(c)

Yes

Is themonitoring in §60.4370(c)(1)

used?

End

§60.4370(c)(1)

No

Comply with the following:Monitoring/Testing§60.4370(c), [G](c)(1)

Recordkeeping§60.4370(c)Reporting

§60.4370(c)

Comply with the following:Monitoring/Testing

§60.4370(c)Recordkeeping

§60.4370(c)Reporting

§60.4370(c)

Yes

No

Yes

34

No

08/09/2016 From 40 CFR Part 60, Subpart KKKK, Amended 03/20/2009The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***