USA WWW.FRIJADO.COM Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014 INSTALLATION MANUAL - NOTICE - This manual is prepared for the use of trained Service Technicians and should not be used by those not properly qualified. If you have atten- ded a training for this product, you may be qualified to perform all the procedures in this manual. This manual is not intended to be all encompassing. If you have not attended training for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the ne- cessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should be performed by a trained technician. Reproduction or other use of this Manual, without the express written consent of Fri-Jado, is prohibited. TDR - ROTISSERIE OVEN MODELS TDW - WARMER MODELS MODELS TDR 5 M TDR 8 M TDW 5 M TDW 8 M TDR 5 P eco TDR 8 P eco TDW 5 P TDW 8 P Model TDR 5 M Model TDR 8 P eco
Transcript
  • USAWWW.FRIJADO.COM Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    INSTALLATION MANUAL

    - NOTICE -This manual is prepared for the use of trained Service Technicians and should not be used by those not properly qualified. If you have atten-

    ded a training for this product, you may be qualified to perform all the procedures in this manual.

    This manual is not intended to be all encompassing. If you have not attended training for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the ne-cessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments

    and skills should be performed by a trained technician.

    Reproduction or other use of this Manual, without the express written consent of Fri-Jado, is prohibited.

    TDR - ROTISSERIE OVEN MODELSTDW - WARMER MODELS

    MODELS

    TDR 5 MTDR 8 MTDW 5 MTDW 8 M

    TDR 5 P eco

    TDR 8 P eco

    TDW 5 PTDW 8 P

    Model TDR 5 M Model TDR 8 Peco

  • Page 2 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

  • TABLE OF CONTENTS

    Page 3 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    VersionsVersion Issue date

    dd/mm/yy

    Remarks

    03/2012 01/03/2012 First release.02/2014 01/02/2014 TDR P and TDRW added.

  • Page 4 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    Index .......................................................................................................................................................... 4

    General technical data .............................................................................................................................. 5

    Installation procedures ............................................................................................................................. 6Unpacking the unit ................................................................................................................................ 6Location .................................................................................................................................................. 7Electrical supply ..................................................................................................................................... 8Legs / Castors .......................................................................................................................................... 9Tethering of the unit ............................................................................................................................. 9Test run ................................................................................................................................................. 10Heat extraction of the rotisserie ......................................................................................................... 10Instructions for operators .................................................................................................................... 10

    Placing and connecting of the models .................................................................................................. 12TDR 5 M Pass Through ........................................................................................................................ 12TDR 5 P Pass Through .......................................................................................................................... 13TDR 8 M Pass Through ......................................................................................................................... 14TDR 8 P Pass Through .......................................................................................................................... 15TDR 5 + 5 M Pass Through ................................................................................................................... 16TDR 5 + 5 P Pass Through .................................................................................................................... 17TDR 8 + 8 M Pass Through ................................................................................................................... 18TDR 8 + 8 P Pass Through .................................................................................................................... 19TDRW 5 M Pass Through ..................................................................................................................... 20TDRW 5 P Pass Through ....................................................................................................................... 21TDRW 8 M Pass Through ..................................................................................................................... 22TDRW 8 P Pass Through ....................................................................................................................... 23TDR 5 M and TDR 5 P Pass Through on base ...................................................................................... 24TDR 8 M and TDR 8 P Pass Through on base ...................................................................................... 25TDW 5 M Pass Through ....................................................................................................................... 26TDW 5 P Pass Through ......................................................................................................................... 27TDW 8 M Pass Through ....................................................................................................................... 28TDW 8 P Pass Through ......................................................................................................................... 29

    INDEX

  • Page 5 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    GENERAL TECHNICAL DATA

    GENERAL TECHNICAL DATA

    This manual covers the TDR series rotisserie ovens and the TDW series warmers. Ovens and

    warming cabinets come in two sizes. Ovens and warmers will also be delivered in stacked

    versions.

    • TDR5–Ovenwith5spits(15to20chickens)or5baskets(15chickens).

    • TDR8-Ovenwith8spits(28to35chickens)or7baskets(28chickens).

    • TDW5-Warmingcabinet25to30chickens.

    • TDW8-Warmingcabinet35to40chickens.

    Alloftheinformation,illustrationsandspecificationscontainedinthismanualarebasedon

    thelatestproductinformationavailableatthetimeofprinting.

    Type TDR 5 TDW 5 TDR 7 TDW 7

    Power(W) 6600 2800 10500 3500

    Fusesneededwithpowerconnec-tion208V,3~60Hz(3phaseswithoutzero)

    3x20A _ 3x40A 3x20A

    Fusesneededwithpowerconnec-tion208V,1N~60Hz(1phasewithzero)

    _ 1x15A _ _

    Standardplugfromfactory NEMA15-30P NEMA6-15P NEMA15-50P NEMA15-20P

    Stackedcabinets:eachcabinetcomeswithseparatepowercord!!

    Netweight(lbs) 287 220 408 331

    Grossweight(lbs) 335 265 476 388

    Height(inch) 353/4” 353/4” 413/4” 413/4”

    Width(inch) 33” 33” 391/4” 391/4”

    Depth(inch) 303/8” 303/8” 35” 35”

    • Standardsetoftools.

    • Metricwrenches,socketsandhexsocketkeywrenches.

    • Multi-meterandACcurrentclampmeter.

    • Temperaturetester.

    • Insulationvaluetester(Megger).

    • FieldServiceGroundingKit.

    X

    Y

    GZ

    G

    X

    Y

    G

    Z

    XY

    G

    Z

  • Page 6 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    INSTALLATION PROCEDURES

    INSTALLATION PROCEDURES

    • Unpackingoftheunit.

    • Removethepalletundertheunitwiththehelpofaforklift.

    • Puttheunitonhislocation.

    • Checkifthereisenoughfreespacearoundtheunit(seeinstallationdrawing).

    • Checktheelectricalsupply.

    • Tetheringoftheunit.

    • TDR:Makeatestrunon482°F.

    • TDW:Makeatestrunon210°F.

    • Giveinstructionstotheoperator.

    UNPACKING THE UNITImmediatelyafterunpackingtheoven,checkforpossibleshippingdamage.Iftheovenisfound

    tobedamaged,savethepackagingmaterialandcontactthecarrierwithin15daysofdelivery.

  • Page 7 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    INSTALLATION PROCEDURES

    LOCATION

    Thestandardwaytoremovetherotisserieor

    warmerfromapalletiswithaforklift.See

    pictures.Opendoorandremovethedrawer.

    Lifttheunitfrompalletandputtheunitin

    itsplace.

    Note: when lifting a stacked unit, always use

    the drawer of the bottom unit.

    Anotherpossibilityistodisassemblethepal-

    let.ForthepalletoftheTDR8followthe

    procedureonthephoto.

    REMOVAL OF PALLET

    Toavoidshort-circuiting,theunitsmaynotbe

    usedoutdoors.Placingunderascreenisallo-

    wed.

  • 1 2 3

    NL1

    1 2 3

    L2L1 L3

    Page 8 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    INSTALLATION PROCEDURES

    Priortoinstallation,testtheelectricalservicetoassurethatitcorrespondswiththespecificati-

    onsonthemachinedataplatelocatedontherightsidepanelnearthecontrols.Theconnecting

    cablefortheunitmustbeequippedwithanapprovedplugconnection.Ifuseistobemadeofa

    permanentconnection,theconnectingcablemustbeconnectedtoamanualon/offswitchthat

    isinstalledneartheunitinaclearvisiblemanner.

    ELECTRICAL SUPPLY

    IMPORTANT: Makesureyoulea-vesufficientspacearoundtherotisserieorwarmertoeasilyremoveorinserttherotor.Ifthebasehas(rotating)wheels,theflooronwhichitrestsmustbelevel.

    Theovenmustbeinstalledonalevelsurface.Theinstallationlocationmustallowadequate

    clearancesforservicingandproperoperation.

    Theconnectingcablefortheunitmustbeequippedwithanapprovedplugconnection.Ifuse

    istobemadeofapermanentconnection,theconnectingcablemustbeconnectedtoamanual

    on/offswitchthatisinstalledneartheunitinaclearvisiblemanner.

    For a single-phase 208 V ~ circuit with neutral, the unit must be connected according to the figure below.

    For a 3-phase 208 V ~ circuit without neutral, the unit must be connected according to the figure below.

    208 V, 1N ~ 50...60 Hz208 V, 3 ~ 50...60 Hz

  • Page 9 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    INSTALLATION PROCEDURES

    Eachovenandwarmerisfurnishedon115/16”legs.Stackedmodelsarefurnishedwith2swivel

    and2lockingswivelcastors.Acastor-equippedstandwithconvenientstoragedrawerisavaila-

    ble;theovenismountedontopofthestand.

    LEGS / CASTORS

    TETHERING OF THE UNIT

    (FormodelTDR5andTDR8unitswhenstackedorplacedonbasewithcastors)

    Warning:Safetystandardsrequirethat,whenthisapplianceisproperlyconnectedtotheelec-

    tricalpowersupplyusingflexibleconduit,adequatemeansbeprovidedtolimitmovementof

    theappliancewithoutdependingonortransmittingstresstotheelectricalconduit.Thismeans

    that,aspartoftheinstallation,thebaseorbottomunitofstackedmodelsmustbesecuredto

    thebuildingstructure(typicallyeitherwallorfloor)tolimitthemovementoftheappliance

    and,thus,helpingtopreventdamagetotheconduitduringcleaning,maintenanceandservice

    operations.

    Atetherbracket,asshownonthedrawingbelow,isprovidedwiththebaseorstackingkit.

    Basedontheroutingoftheflexibleconduit,thebracketmustbeinstalledalongwiththecaster

    toonecornerofthebaseusingthehardwareprovided.Theremainingopenholeinthecenter

    ofthetetherbracketistobeusedtosecureoneendofthetether(locallysuppliedchain,cable,

    etc.).Theotherendofthetetheristobesecuredtoananchoringpointinthebuildingstruc-

    ture.

    Note: Length of tether must be shorter than the flexible conduit to make sure that during appli-

    ance movement, no stress is transmitted to the conduit.

    Warning:Followinginstallation,checktoconfirmthat,whentheapplianceismovedtothe

    limitsofthetetherineachdirection,nostressistransmittedtotheelectricalconduit.

  • Page 10 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    INSTALLATION PROCEDURES

    Afterinstallationoftherotisserieorwarmer,theoperatoroftheunithastobeinstructed.

    Theinstructionhastocoverthefollowingsubjects:

    • Programmingandoptions.

    • Workingoftheunit.

    • Freespaceofunitforcoolingofdrivemotorandblowers.

    • Reviewtheusermanual.

    • Periodicalmaintenance:

    o Cleaningoffanplateeverymonth.

    • Howtoreactforinformationorservicecalls.

    INSTRUCTIONS FOR OPERATORS

    Theovenmustbeburnedintoreleaseanyodorsthatmightresultfromheatingthenewoven

    surfaces.Operatetheovenatmaximumtemperaturesettingof482°Ffor30minutesandthe

    warmeron210°F.Smokewithanunplaesantodourwillnormallybegivenoffduringthisburn-

    inperiod.

    TEST RUN

    Althoughanextractionhoodisnotprescribed,itcouldbedesiredthatahoodisplacedover

    therotisserie.TheTDR8producesabout350cfwatervapourandtheTDR5about200cf.When

    placingtherotisserieunderanextractionhoodyouhavetoconsiderthefollowingguidelines:

    -Theminimumcapacityoftheextractionhoodhastobe25000cf/h.

    -Theextractionhoodhastoextendminimumby8”onallsidesoftherotisserie.

    -Theextractionhoodhastohaveafreehight,abovetherotisserie,ofaminimumof12”.

    -Therotisseriehastobeaccessibleforservicepurposes.

    -Theextractionhoodhastobeslopingontheinsideforthecondensationtorundown.Around

    thehoodtherehastobeagutterwithaconnectionforthewatertorundownadrain.

    HEAT EXTRACTION OF THE ROTISSERIE

  • Page 11 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

  • Page 12 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    Description belonging to the lables on the drawingsLabel Description

    1 Power cable, length 70” *

    2 Exhaust opening

    3 Space between a rotisserie and a wall or ceiling

    4 Location for socket

    *) length is measured from the point where the cables coms out of the unit

    TDR 5 M PASS THROUGH

    PLACING AND CONNECTING OF THE MODELS

  • Page 13 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 5 P PASS THROUGH

  • Page 14 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 8 M PASS THROUGH

  • Page 15 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 8 P PASS THROUGH

  • Page 16 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 5 + 5 M PASS THROUGH

  • Page 17 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 5 + 5 P PASS THROUGH

  • Page 18 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 8 + 8 M PASS THROUGH

  • Page 19 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 8 + 8 P PASS THROUGH

  • Page 20 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDRW 5 M PASS THROUGH

  • Page 21 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDRW 5 P PASS THROUGH

  • Page 22 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDRW 8 M PASS THROUGH

  • Page 23 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDRW 8 P PASS THROUGH

  • Page 24 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 5 M AND TDR 5 P PASS THROUGH ON BASE

  • Page 25 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDR 8 M AND TDR 8 P PASS THROUGH ON BASE

  • Page 26 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDW 5 M PASS THROUGH

  • Page 27 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDW 5 P PASS THROUGH

  • Page 28 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDW 8 M PASS THROUGH

  • Page 29 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    PLACING AND CONNECTING

    TDW 8 P PASS THROUGH

  • Page 30 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    EMPTY PAGE

  • Page 31 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014

    EMPTY PAGE

  • For technical support call: 877 374-5236For parts call: 877 392-7851

    Fri-Jado Inc. •1401 Davey Road • Sweet 100 • Woodridge, IL. 60517 • USA • tel. 630-630-7950 • fax 630-689-11424 • toll free 877-FRI-JADO • [email protected] • www.frijado.com


Recommended