4
VITOSOL 300 Vacuum tube solar collector utilizing the heat pipe principle to harness solar energy VITOSOL 300 Model SP3 Vacuum tube solar collector for vertical, or angled installation on sloped or flat roofs To produce domestic hot water, or to supplement low-temperature heating systems or swimming pools via a heat exchanger, as well as the generation of process heat. Technical Data Manual Model Nos. and Pricing: see Price List Meets the requirements of the German “Blue Angel” certificate of environmental excellence to RAL UZ 73. Certified in accordance with DIN ISO 9001. SPF quality seal from the Solar Energy Testing and Research Institute in Rapperswil, Switzerland. 5167 567 v1.2 02/2006
Transcript

VITOSOL 300Vacuum tube solar collector utilizing the

heat pipe principle to harness solar energy

VITOSOL 300 Model SP3

Vacuum tube solar collector

for vertical, or angled installation onsloped or flat roofs

To produce domestic hot water, or to supplementlow-temperature heating systems or swimming pools via a heatexchanger, as well as the generation of process heat.

Technical Data ManualModel Nos. and Pricing: see Price List

Meets the requirements of the German “Blue Angel”certificate of environmental excellence to RAL UZ 73.

Certified in accordance with DIN ISO 9001.

SPF quality seal from the Solar Energy Testing andResearch Institute in Rapperswil, Switzerland.

5167 567 v1.2 02/2006

Product Information

2

Vitosol 300Model SP3

The benefits at a glance:

H High level of operational reliability and along service life thanks to the use ofhigh-grade, corrosion-resistant materialssuch as borosilicate solar glass, copperand stainless steel. Durable, vacuum-tightglass-to-metal seals.

H Extremely high efficiency thanks to theSol-titanium coated absorber; the vacuumcollector tubes greatly reduce heat losses.

H Superior heat utilization by the patented“Duotec” double-pipe heat exchangerwhich almost completely encloses thecondensers for better heat transfer.

H Flexible connection between vacuum tubeand condenser due to a corrugated pipe.The individual tubes can be rotated foroptimum alignment to the sun.

H Straight-forward installation and servicethanks to dry connection of collectortubes. Individual tubes can be installedand disassembled without having to drainthe solar system.

H Fast installation times due to provenplug-in system for the connection ofseveral collectors to form one collectorpanel (max. surface area 65 ft.2 / 6 m2).

H Vacuum tube design outperformsconventional flat-plate collectors in cold,cloudy or windy conditions. Ideally suitedfor year round energy collection in coldweather climates.

H Built-in temperature limiter inside thecondenser controls the heat flow at veryhigh collector temperatures, protecting theheat transfer fluid.

LegendDuotec double-pipe heat exchangerBronze flexible couplingSol-titanium coated absorber plateHeat pipeInsulation

Construction and function

Vitosol 300 vacuum tube solar collectorsare available as two models:H 2m2 with 20 tubesH 3m2 with 30 tubes

Built into each vacuum tube is a Sol-titaniumcoated copper absorber, ensuring a highabsorption rate of solar radiation and lowemission of thermal radiation.

A heat pipe filled with an evaporator liquid isplaced on the absorber and connected to thecondenser in the Duotec double-pipe heatexchanger via a flexible coupling.A so-called ”dry connection” between theheat pipe and the heat exchanger allowspipes to be rotated or replaced even whenthe installation is filled and under pressure.Solar energy is transferred to the heat pipe,causing the liquid to evaporate. The vaporrises into the condenser. Heat is conveyed to

Duotec double-pipeheat exchangerCondenserAbsorberHeat pipeVacuum glass tube

Vitosol 300 - vacuum tube collector basedon the heat pipe principle

the passing heat transfer medium (glycol /water) by the double-pipe heat exchangercontaining the condenser; this causes thevapor to condense. The condensate flowsback into the heat pipe and the process isrepeated.

The angle of inclination of the collector mustbe at least 25°, in order to guarantee acirculation of the evaporator liquid in theheat exchanger. Corrections for deviationsfrom south can be made by rotating thevacuum tubes.

By means of flexible and insulatedconnection pipes sealed with O-rings severalcollectors can be joined to form a totalcollector surface area of up to 65 ft.2 /6 m2.

A connection kit with clamping ringconnections facilitates the attachment of thecollector panel to the piping of the solarcircuit.The collector temperature sensor is installedin a sensor mounting clip directly on theDuotec heat exchanger inside theconnection housing of the collector.

5167

567

v1.2

Technical Data

3

Technical DataModel SP3

2m2SP33m2

Number of tubes 20 30

Gross area ft.2 / m2 30.5 / 2.83 45.6 / 4.24

Absorber surface area ft.2 / m2 22 / 2.05 33 / 3.07

Aperture area*1 ft.2 / m2 22.7 / 2.11 34.1 / 3.17

DimensionsWidth (a)

Height (b)

Depth (c)

inchesmminchesmminchesmm

55¾141978½19964¾122

83¾212678½19964¾122

Optical efficiency*2 % 82.5 82.5

Heat loss coefficient U1Heat loss coefficient U2

W/(m2⋅K)W/(m2⋅K)

1.190.009

1.190.009

Thermal capacity kJ(m2⋅K) 5.4 5.4

Weight lbs / kg 99 / 45 150 / 68

Fluid capacity(heat transfer medium)

USGltr

0.321.2

0.481.8

Maximum working pressure*3 psigbar

876

876

Maximum stagnation temperature*4 ºF / ºC 302 / 150 302 / 150

Connection ∅ inchesmm

¾22

¾22

Space requirement for flatroof installations ft.2 / m2 approx. 15.6 / 1.45 approx. 20.5 / 1.9

Requirements for installation surface andanchorage

Roof construction with adequate load capacity for prevailing wind forcesMinimum angle of inclination: 25º

*1 Used when sizing the system.*2 Based on the absorber surface area.*3 In sealed systems, operating pressure of at least 22 psig + 0.45 psig x static head (ft.) / 1.5 bar + 0.1 bar x static head (m) must be

present in the collectors in cold condition.*4 The stagnation temperature is the temperature which applies to the hottest point of the collector at a global radiation intensity of

3412 Btu/h / 1000 W when no heat is conducted by the heat transfer medium.

5167

567

v1.2

CRCS

2.6” / 65 mm Ø

CR Collector return (inlet)CS Collector supply (outlet)

Standard Equipment

Viessmann Manufacturing Company Inc.750 McMurray RoadWaterloo, Ontario • N2V 2G5 • CanadaTel. (519) 885-6300 • Fax (519) 885-0887www.viessmann.ca • [email protected]

Viessmann Manufacturing Company (U.S.) Inc.45 Access RoadWarwick, Rhode Island • 02886 • USATel. (401) 732-0667 • Fax (401) 732-0590www.viessmann-us.com • [email protected]

x4

x2

4

Standard equipment

The following are packaged in separatecartons:– Insulated distribution header withinstallation railsand Technical Literature

– Vacuum tubes (10 per box)

Accessories (individually packaged,depending on order):- Mounting accessories- Connecting pipes with insulation- General connection set- Solar-Divicon (pumping station for collectorcircuit)

- Vitotronic differential control- Air separator- Quick-acting air vent valve with tee andclamping ring connection

- System filling manifold- Solar hand pump- Solar expansion tank- Safety pressure relief valve- Heat transfer medium- Antifreeze tester- Set of spare parts (assortment of smallparts which may be misplaced duringinstallation of collectors)

Heat transfer medium

Tyfocor non-toxic liquid for solar heatingsystems with active anti-corrosion andanti-ageing protection.Frost protection: to -31°F / -35°CSpecific gravityat 68°F / 20°C: 1.032 to 1.035 g/cm3 to

ASTM D 1122Viscosityat 68°F / 20°C: 6.5 to 8.0 mm2/s to

DIN 51562pH value: 7.5 to 8.5 to

ASTM D 1287Color: transparent, blue-greenContainer: 5.3 USG / 20 ltr. in a

disposable container

Accessories

General connection setRequired to connect solar collector tosystem piping. One set required per collectorarray - max. 65 ft.2 / 6 m2

Part No. 7188 914

Pipe connection setRequired to connect multiple solar collectorsPart No. 7188 920

Sloped roof hardware kitRequired for direct-mounting of collector toshingled roofPart No. Z003 335

Flat roof hardwarePart No. 7188 862

Solar DiviconPreassembled pumping station for solarcollector circuit.Includes: system pump (2 sizes), pressuregage, 2 thermometers, 2 ball valves,pressure relief valve, flow meter and foaminsulation cover.Part No. 7133 454 (for PS10)

7133 455 (for PS20)

Vitosolic 200Electronic differential temperature controlfor solar heatingPart No. 7134 552

Main menu:Actual valuesReportsSolar

5167

567

v1.2

Printedon

environm

entally

friend

ly(rec

ycledan

drecy

clab

le)pa

per.

Tec

hnical

inform

ation

subjec

tto

chan

gewitho

utno

tice

0

20

4060

80

100

120 0

20

4060

80

100

120


Recommended