4
Document type: Created: Page: SERVICE BULLETIN (2009-04-01) Page 1 of 4 THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB 2009 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN |. Technical Service Bulletin no. 11 Created by: Lab.gruppen AB Service Department Date: 090401 Reference no: PLM Series DLP board Affected models Following models are affected by this technical service bulletin: PLM 10000Q PLM 14000 Affected boards/modules DLP403b, DLP403c DLP404a, DLP404b, DLP404c DLP405a-F01 Symptom Display says “analogue input fault”. Solution Check soldering at transformer, see picture. Re-solder pins at transformer. Note The soldering can look ok but when checking close one or more pins at the transformer is not properly soldered. See pictures for example.
Transcript
Page 1: Technical Service Bulletin no. 11 - Lab.gruppendownloads.labgruppen.com/Service Bulletin 2009 no 11_PLM Series … · Created by: Lab.gruppen AB Service Department Date: 090401 Reference

Document type: Created: Page:

SERVICE BULLETIN (2009-04-01) Page 1 of 4

THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB

2009 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN |.

Technical Service Bulletin no. 11 Created by: Lab.gruppen AB Service Department Date: 090401 Reference no: PLM Series DLP board

Affected models

Following models are affected by this technical service bulletin:

PLM 10000Q

PLM 14000

Affected boards/modules

DLP403b, DLP403c

DLP404a, DLP404b, DLP404c

DLP405a-F01

Symptom

Display says “analogue input fault”.

Solution

Check soldering at transformer, see picture. Re-solder pins at transformer.

Note

The soldering can look ok but when checking close one or more pins at the transformer is not

properly soldered. See pictures for example.

Page 2: Technical Service Bulletin no. 11 - Lab.gruppendownloads.labgruppen.com/Service Bulletin 2009 no 11_PLM Series … · Created by: Lab.gruppen AB Service Department Date: 090401 Reference

Document type: Created: Page:

SERVICE BULLETIN (2009-04-01) Page 2 of 4

THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB

2009 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN |.

Pictures valid for all models of boards

Examples of unsoldered pins

Page 3: Technical Service Bulletin no. 11 - Lab.gruppendownloads.labgruppen.com/Service Bulletin 2009 no 11_PLM Series … · Created by: Lab.gruppen AB Service Department Date: 090401 Reference

Document type: Created: Page:

SERVICE BULLETIN (2009-04-01) Page 3 of 4

THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB

2009 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN |.

Page 4: Technical Service Bulletin no. 11 - Lab.gruppendownloads.labgruppen.com/Service Bulletin 2009 no 11_PLM Series … · Created by: Lab.gruppen AB Service Department Date: 090401 Reference

Document type: Created: Page:

SERVICE BULLETIN (2009-04-01) Page 4 of 4

THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB

2009 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN |.

Part numbers

Model 115V part number 230V part number

PLM 10000Q - -

PLM 14000 - -

History

Date Created By Status Bulletin no. Comment

090401 JF SHARP 11