operating guidelines temperature correction factors Temperature Correction Factor
A temperature correction factor (TCF) is used to normalize the flowrate.
Example: A system running at 200 GPD @ 35°C with a CA membrane must now be normalized to 25°C.
From table: TCF=1.2894 The flowrate (or flux value) is divided by the TCF to obtain the normalized flow rate: Normalized flow = 200 gpd / 1.2894 = 155 gpd @ 25°C
TFM: Thin-Film Membrane.
Temperature Correction Factors @ 77°F (25°C)