+ All Categories
Home > Documents > the experts for your integrated fire protection systems · 2020. 12. 17. · Semco Maritime and...

the experts for your integrated fire protection systems · 2020. 12. 17. · Semco Maritime and...

Date post: 03-Feb-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
3
the experts for your integrated fire protection systems innovative consultancies safety engineering
Transcript
  • the experts for your integrated fire protection systems

    innovative consultancies safety engineering

  • Fire Safety Engineering & Consultancy Services

    Experience:INCOS Engineering personnel/engineers have worked for INMACO,

    Semco Maritime and Norfass with the first operating since 2002

    supplying Fire and Safety System to more than 70 FPSO’s / Offshore Oil

    & Gas Facilities. Some references are; Woodside Laminaria - Northern

    Endeavor – Okha - Vincent, ConocoPhillips Bayu-Undan, Marathon

    Alvheim, Maersk Peregrino, Bluewater AkoaMizu, TeekayPetrojarl Siri

    and FPSO (Knarr), PTTEP (TPOT) Montara, INPEX Icthys.

    Key personnel engineers with individually more than 25 years-

    experience and daily use of international standards including DNV,

    ABS, Lloyds, GL, BV, AS, ATEX, IECEX, ASME, API, ANSI, BS, ISO, NMD,

    NORSOK, NFPA, PED, SIL, SOLAS, UL, IMO etc.

    Capabilities:

    FEED / CONCEPTUAL ENGINEERING• Hazardous Area Evaluation, Fire Risk consideration, preparation of Fire Protection equipment / system specifications• Material and Corrosion Technology; advisory on suitable materials for Fire water Systems• Review of applicable environmental regulations/policies/guidelines and performance standards for foam concentrate selection

    BASIC ENGINEERING• Preparation of Fire Protection Plot Plans, Piping and Instrument Diagrams• Design of deluge distribution piping• Preparation of technical proposals from analysis of specification and standards, evaluating options/alternatives, designing/sizing• Fluid mechanic calculations: Pressure, flow rate, head losses, pump duties, (using software Pipenet, Bernoulli’s principles, Darcy-Weisbach and

    Hazen-Williams equations etc)• Nozzle/discharge equipment selection (coverage, throw/reach, foam expansion ratio)

    DETAILED ENGINEERING• Design of deluge, sprinkler, foam nozzles layout drawings• Perform Hydraulic calculations and balancing of deluge piping distribution systems• Foam concentrate proportioning calculations and proportioner’s selection• Write System functional specifications

    PRE-OPERATION• Installation and Commissioning Procedures• Generic Maintenance Strategies and Preventive Maintenance Programs• Equipment Operations Performance Standards and testing programs

    OPERATION• Optimisation of Operators Programs for Inspection, Testing, and Maintenance• Performance Strategy and testing procedures • Site surveys and review of facilities fire water systems • Provide specialised expertise in the design, testing and commissioning for fire protection

    systems (sprinklers, deluge, foam, hydrants, hose reels, gaseous systems etc)• Foam concentrate transition feasibility review• Life Extension Programs

    DE-COMMISSIONING• Environmental Management of Fire fighting Foam Policy• Fire fighting foam and fire water waste inevitably contain components that class as regulated

    wastes that require special handling, treatment and disposal

    Base Scenario 2Geoman Consulting Pty

    PIPENET Schematic Page 1 of 1Wednesday, January 29, 2020

    FW-0

    32

    113

    115

    116

    118

    FW-020

    120

    121

    FW-0

    35

    123

    125

    126

    128

    FW-023

    130

    131

    132

    133

    134

    135

    FW-6

    16

    117

    124

    127

    136

    FW-617

    138

    139

    FW-1994FW-1993FW-1992

    FW-0

    26

    129

    137

    140

    141

    FW-014

    143

    144

    145

    146

    147

    148

    FW-017

    150

    151

    152

    153

    FW-0

    29

    155

    156157

    158

    159

    160

    FW-016

    162

    163

    164

    165

    FW-0

    28

    167

    168

    169

    170

    171

    172

    FW-718

    175

    FW-7

    15

    180

    181

    182

    183

    184

    185

    186

    187

    188

    FW-0091 FW-0092 FW-0093

    FW-1981 FW-1982

    FW-00913FW-00911FW-00910FW-0095

    FW-1983

    FW-1985

    FW-1985

    FW-0094

    FW-1984

    FW-612

    FW-6

    13

    177

    178

    FW-0096

    174

    FW-0099FW-0098FW-0097

    190FW

    -007

    FW-005

    FW-003

    FW-001

    195196

    197 198

    FW-171

    FW-171

    FW-171

    FW-172

    FW-172

    FW-172

    201

    202

    203 204 205 206

    FW-0

    0920

    FW-00920 FW-00915FW-00919 FW-00914

    FW-00914

    FW-00914FW-00912

    FW-00916

    FW-1

    991

    FW-1991

    FW-00918 FW-00917

    FW-00921

    1

    2

    4

    5

    6 7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    3

    60

    61

    222324

    25

    26

    27

    28

    29

    30

    31

    32

    33 34 35 36

    36

    37 38

    39

    40

    41

    42

    43

    21

    44

    44

    45

    20

    20

    46

    46

    47

    1

    2

    4 3 5

    P-001-A

    P-001-D

    P-002-B

    P-002-A

    P-001-B

    P-001-C

    DXV-071

    DXV-131

    DXV-141

    DXV-161

    DXV

    -162

    DXV

    -142

    DXV

    -132

    DXV

    -072

    DXV-041

    DXV-051

    DXV-061

    DXV

    -042

    DXV

    -052

    DXV

    -062

    DXV-111

    DXV-121

    DXV-151

    DXV

    -112

    DXV

    -122

    DXV

    -152

    DXV-201

    DXV-090

    DXV-091

    DXV

    -202

    DXV

    -093

    DXV

    -092

    DXV-211

    DXV-221

    DXV-231

    DXV-021

    DXV-011

    DXV-081

    DXV-101

    DXV

    -212

    DXV

    -222

    DXV

    -232

    DXV

    -022

    DXV

    -012

    DXV

    -082

    DXV

    -102

    STAINER

    STAINER STAINER STAINER

    STAINER STAINER

    STAINER

    STAINER

    STAINER

    STAINER

    STAINER

    STAINER

    STAINER

    STAINER

    STAINER

    STAINER

    schroeder valve schroeder valve

    Water Spray Calculation for 792-DXV-0019 (LNG Train) Geoman Consulting Pty

    PIPENET Schematic Page 1 of 1Wednesday, January 29, 2020

    DELUGE VALVE791-DXV-0019

    L-601-P-001

    L-601-V-004

    L-601-V-008

    L-601-V-001

    From Bypass Line

    FW733 1GA1 10391

    FW734 1GA1 100395

    F808-1GA1 10606

    F731- 1GA1 10682

    FW732 1GA1 10688 FW732-1GA1 10684

    FW785 1GA1 10060

    FW785 1GA1 10425

    FW733 1GA1/03 10394

    Demand 7434 l/min @ 7.54barg using INPEX layout

    INCOS use the globally recognised computer program “PIPENET” for hydraulic calculations.

    Specifically intended for the design of fire protection systems. PIPENET Spray/Sprinkler complies with the NFPA13, NFPA15 and NFPA16 rules. The module is used for designing a wide range of fire protection systems i.e. sprinkler, deluge, ring-main, and foam solution.

    The result of the hydraulic design process is a written report discussing the results from the computer calculations, a noded isometric drawing, and the actual printout of the hydraulic report. Our Engineers have experience in evaluating the results obtained from the calculation program, and will give recommendations needed to obtain the most balanced and efficient fire water distribution system.

    Safety design is a process defined as the integration of hazard identification and risk assessment methods early in the design process to eliminate or minimise the risks of injury throughout the life of a structure being designed. Safe design is everybody’s business - from clients to designers to constructors.

    Subject matter experts within Active Fire Protection Systems.

    In summary we ensure the facts and details are correct so that

    the project’s/program’s deliverables will meet the needs of the

    stakeholders, legislation, policies, standards, and best practices.

    FEED /ConceptualEngineering

    BasicEngineering

    DetailedEngineering Pre-Operation Operation

    De-commisioning

  • Maintenance Engineering

    PREVENTIVE MAINTENANCE

    Planned and meticulous maintenance of facility assets,

    equipment and infrastructure is the key component to

    continuous and sustained operations in the field.

    Incos Engineering Programmed Service & Maintenance

    provides assurances to the customer that all is being

    done to provide continuous uninterrupted operation by

    maximising functional reliability and effectiveness of the

    safety critical Firewater system.

    SAFETY, SAFETY, SAFETY!

    Potential hazards in the oil and gas industry are well-

    documented. Accidents lead to safety incidents and loss of

    production that can damage entire regions. Safety must be

    an integral element in every facet of industry operation.

    Common sense tells us that proper maintenance of oil

    and gas processing facilities is key, in today’s tight energy

    market, to ensure continuous, uninterrupted operation.

    PLANT RELIABILITY

    Ensuring minimal damage to the environment is caused as a result of oil and gas operations. Reliability and safety go hand-in-hand,

    making sure that major incidents with the potential to affect the workforce and wider community occur as infrequently as possible.

    Poor plant reliability also causes uncertainty among both investors and customers, ultimately impacting on the bottom line.

    www.incos-e.com

    +61 8 6252 [email protected] Ernest Clark RoadCanning Vale, Western Australia, 6155

    ABN: 91 629 733 508 | Trading as: INCOS EngineeringOffshore Oil & Gas, Onshore Petrochemical Industries and Marine Support

    the experts for your integrated fire protection systems