2Soprema Group

20°C

I

20°C

IV

20°C

10°C

II

20°C

I

20°C

III

The floor heating with radiant panels is the system with the highest energetic efficiency widely spread in all European countries, which allows to design and build buildings in high Energy Class (Gold Class, Class A Plus etc.). The principle of operation of the system with radiating panels is based on the circulation of hot water at low temperature, typically between 30 ° C and 40 ° C, in a closed circuit, which is spread by covering a very high radiating surface.

The European Norm governing the design and installation of heating floor is EN 1264 (waterbased surface embedded heating and cooling system), which applies to all residential buildings, offices and other buildings the use of which corresponds or it is similar to that of residential buildings (eg. hotels, nursing houses, colleges, convents, barracks, etc.). This Norm covers the main definitions and their symbols, related to the installations with underfloor heating, fed with hot water, used in residential or similar. It does not apply to heating systems with wooden floor, while it can be used in the case where other heating means are used instead of water.

The Norm EN 1264 is structured into 5 parts:

• EN 1264-1: 2011 Definitions and symbols

• EN 1264-2: 2008, A1:2012 Floor heating: prove methods for the determination of the thermal output using calculation test methods • EN 1264-3: 2009: Dimensioning of both heating and cooling system - effective thickness• EN 1264-4: 2009 Installation

• EN 1264-5: 2008 Heating and cooling surfaces embadded in floors, ceilings and walls -Determination of the thermal output

The NORM EN 1264-4, at paragraph 4.1.2.2.1 table1, recommends what should be the minimum values of thermal resistance (RD) of the insulating panels used in the underfloor heating systems, distinguishing five different cases, based on the conditions existing under the heated rooms. These minimum values of thermal resistance (RD) translate in EFFECTIVE THICKNESSES reported in the following tables for the various types of insulating boards used.

FloorPossible vapour barrier

STIROFLOOR insulating board

Heating pipe

MeshConcrete deck

Floor

Perimetral band PERIFLOOR

AN EXAMPLE OF STRATIGRAPHY OF THE RADIANT PANEL

Minimum values of thermal resistance RD according to the Norm EN 1264-4

Heated room below or adjacent

Unheated orintermittent heated room

below, adjacent or directly on the ground

External air temperature below or adjacent

External design temperature

T ≥ 0 °C

External design temperature0°C > T ≥-5°C

External design temperature

-5°C > T ≥-15°C

Thermal Resistance

RD0,75 m2K/W 1,25 m2K/W 1,25 m2K/W 1,50 m2K/W 2,00 m2K/W

Page 3: The floor heating system with radiant panels

The floor heating system with radiant panels

3Soprema Group

TECKFLOOR

Pre-shaped EPS polystyrene insulation boards, CFC and HCFC free, joined to a high thickness thermoformed film with stubs and selvages on the semiperimeter, in accordance with Norm EN 13163, for the realization of heating system with radiant floors.

TECKFLOOR - B: 1400x800 mm

Pitch: 5

Technical properties Norm

EPS Class

Thickness of HIPS layer

Useful Width

Dimensional tolerance on thickness

Compressive strength at 10% max deformation

Declared thermal conductivity λD at 10°C

Useful Length

Pitch (wheelbase of laying)

Dimensional tolerance on length and width

Squareness

Diameter of heating pipe (recommended)

EN 13163

EN 823

EN 822

EN 823

EN 826

EN 12667

EN 822

-

EN 822

EN 824

-

TECKFLOOR - B

150

0,6

800

±2

≥150

0,034

1400

5

±0,6

±2

16 ÷18

120

0,6

800

±2

≥120

0,035

1400

5

±0,6

±2

16 ÷18

M.U.

-

mm

mm

mm

kPa

W/mK

mm

cm

%

mm/m

mm

TECKFLOOR - B

m2/boardProduct

1,12

1,12

1,12

1,12

1,12

1,12

1,12

Teckfloor - B 33

Teckfloor - B 63

Teckfloor - B 45

Teckfloor - B 90

Teckfloor - B 43

Teckfloor - B 70

Teckfloor - B 53

Boards n./pallet m2/pallet

14

6

10

4

10

6

8

15,68

6,72

11,20

4,48

11,20

6,72

8,96

TECKFLOOR - B

Values of thermal resistance RD of the insulating boards used in function of the effective thickness.(The effective thickness - “average effective thickness” was calculated according to the Norm EN 1264-3)

TECKFLOOR - B: 1400x800 mm (stub 23 mm)

ProductCLASS 120 CLASS 150

EFFECTIVE thickness (mm)Norm 1264-3

RD

(m2K/W)EFFECTIVE thickness (mm)

Norm 1264-3RD

(m2K/W)

Teckfloor - B 33 (10 + stub) 13,9 0,35 13,9 0,40

Teckfloor - B 43 (20 + stub) 23,9 0,65 23,9 0,70

Teckfloor - B 45 (22 + stub) 26,3 0,75 26,3 0,75

Teckfloor - B 53 (30 + stub) 33,9 0,95 33,9 0,95

Teckfloor - B 63 (40 + stub) 43,9 1,25 43,9 1,25

Teckfloor - B 70 (48 + stub) 52,5 1,50 52,5 1,50

Teckfloor - B 90 (67 + stub) 70,0 2,00 70,0 2,05

The values of RD in orange cells are the minimum values established by the Norm EN 1264-4

Page 4: The floor heating system with radiant panels

The floor heating system with radiant panels

4Soprema Group

The values of RD in orange cells are the minimum values established by the Norm EN 1264-4

STIROFLOOR

Thermoformed expanded polystyrene boards, CFC and HCFC free, with a high-impact polystyrene film (HIPS), with stubs and interlocking, according to the European Norm EN 13163, for the realization of heating systems with radiant floors.

Useful dimensions: 1200x700 mm

Pitch: 5

Technical properties Norm

EPS Class

Useful Width

Dimensional tolerance on thickness

Compressive strength at 10% max deformation

Declared thermal conductivity λD at 10°C

Useful Length

Pitch (wheelbase of laying)

Dimensional tolerance on length and width

Squareness

Diameter of heating pipe (recommended)

EN 13163

EN 822

EN 823

EN 826

EN 12667

EN 822

-

EN 822

EN 824

-

STIROFLOOR 200STIROFLOOR 150

200

700

± 2

≥200

0,033

1200

5

± 0,6

± 2

16÷18

150

700

± 2

≥150

0,034

1200

5

± 0,6

± 2

16÷18

M.U.

-

mm

mm

kPa

W/mK

mm

cm

%

mm/m

mm

STIROFLOOR 150 - 200

m2/boardProduct

0,84

0,84

0,84

0,84

0,84

0,84

0,84

Stirofloor 35

Stirofloor 60

Stirofloor 43

Stirofloor 70

Stirofloor 40

Stirofloor 65

Stirofloor 50

Board n./pallet m2/pallet

20

10

14

8

16

9

12

16,80

8,40

11,76

6,72

13,44

7,56

10,08

STIROFLOOR 150 - 200: mm 1200x700 (stub 20 mm)

ProductCLASS 150 CLASS 200

EFFECTIVE thickness (mm)Norm 1264-3

RD

(m2K/W)EFFECTIVE thickness (mm)

Norm 1264-3RD

(m2K/W)

Stirofloor 35 (15+stub) 18,1 0,50 18,1 0,55

Stirofloor 40 (20+stub) 22,0 0,65 22,0 0,65

Stirofloor 43 (23,5+stub) 25,5 0,75 25,5 0,75

Stirofloor 50 (30+stub) 32,0 0,90 32,0 0,95

Stirofloor 60 (40+stub) 42,5 1,25 42,5 1,25

Stirofloor 65 (45+stub) 47,0 1,35 47,0 1,40

Stirofloor 70 (50+stub) 52,0 1,50 51,0 1,55

Packaging in cardboard boxeswith two-sides openingand cross straps.

The boxes areput on EPSplanks.

Values of thermal resistance RD of the insulating boards used in function of the effective thickness.(The effective thickness - “average effective thickness” was calculated according to the Norm EN 1264-3)

Page 5: The floor heating system with radiant panels

The floor heating system with radiant panels

5Soprema Group

The values of RD in orange cells are the minimum values established by the Norm EN 1264-4

Technical properties

EPS Class

Useful Width

Dimensional tolerance on thickness

Compressive strength at 10% max deformation

Declared thermal conductivity λD at 10°C

Useful Length

Pitch (wheelbase of laying)

Dimensional tolerance on length and width

Squareness

Diameter of heating pipe (recommended)

PAVIFLOOR

Thermoformed expanded polystyrene boards, CFC and HCFC free, with a high-impact polystyrene film (HIPS), with stubs and interlocking, according to the European Norm EN 13163, for the realization of heating systems with radiant floors.

Useful dimensions: 1350x750 mm

Pitch: 7,5

Norm

EN 13163

EN 822

EN 823

EN 826

EN 12667

EN 822

-

EN 822

EN 824

-

PAVIFLOOR 200PAVIFLOOR 150

200

750

± 2

≥200

0,033

1350

7,5

± 0,6

± 2

16÷18

150

750

± 2

≥150

0,034

1350

7,5

± 0,6

± 2

16÷18

M.U.

-

mm

mm

kPa

W/mK

mm

cm

%

mm/m

mm

PAVIFLOOR 150 - 200

m2/boardProduct

1,0125

1,0125

1,0125

1,0125

1,0125

1,0125

Pavifloor 47

Pavifloor 72

Pavifloor 60

Pavifloor 50

Pavifloor 90

Pavifloor 63

n.board/pallet m2/pallet

13

8

10

10

6

9

13,162

8,100

10,125

10,125

6,075

9,112

Values of thermal resistance RD of the insulating boards used in function of the effective thickness.(The effective thickness - “average effective thickness” was calculated according to the Norm EN 1264-3)

PAVIFLOOR 150 - 200: mm 1350x750 (stub 20 mm)

ProductCLASS 150 CLASS 200

EFFECTIVE thickness (mm)Norm 1264-3

RD

(m2K/W)EFFECTIVE thickness (mm)

Norm 1264-3RD

(m2K/W)

Pavifloor 47 (27 + stub) 25,6 0,75 25,6 0,75

Pavifloor 50 (30 + stub) 29,3 0,85 29,3 0,85

Pavifloor 60 (40 + stub) 39,3 1,15 39,3 1,15

Pavifloor 63 (43 + stub) 42,5 1,25 42,5 1,25

Pavifloor 72 (52 + stub) 51,3 1,50 51,3 1,55

Pavifloor 90 (70 + stub) 69,3 2,00 69,3 2,10

Packaging in cardboard boxeswith two-sides openingand cross traps.

The boxes areput on EPSplanks.

Page 6: The floor heating system with radiant panels

The floor heating system with radiant panels

6Soprema Group

The values of RD in orange cells are the minimum values established by the Norm EN 1264-4

STIROFLEX EPS - XPS

Roll length (m)Product

12

6

8

10

5

6

Stiroflex 20

Stiroflex 42,5

Stiroflex 30

Stiroflex 25,5

Stiroflex 52,5

Stiroflex 40

m2/roll

12

6

8

10

5

6

Dimensional tolerance on thickness

Dimensional tolerance on length and width

± 2 ± 2

± 0,6% ± 0,6%

± 2

± 0,6%

EN 823

EN 822

mm

mm

STIROFLEX

Rolls consisting of pre-cut extruded or expanded polystyrene foam in complementary slats according to the Norm EN 13163 and EN 13164 with outer covering with aluminated polyethylene film, with longitudinal adhesive selvedge, screen printed with regular meshes to facilitate the laying of the pipe heating.

STIROFLEX - EPS: with EPS staves

STIROFLEX - XPS: with XPS staves

Technical properties

EPS Class

Useful Width

Declared thermal conductivity λD at 10°C

Compressive strength at 10% max deformation

Useful Length

STIROFLEX EPS STIROFLEX XPSSTIROFLEX EPS

200 -

1 1

0,033

≥ 200

thick. 20 - 0,037thick. 30 - 0,033thick. 40 - 0,033thick. 50 - 0,034

thick. 20 - ≥ 400thick. 30 - ≥ 250thick. 40 - ≥ 250thick. 50 - ≥ 300

4 ÷ 12 4 ÷ 12

150

1

0,034

≥ 150

4 ÷ 12

Norm

EN 13163

EN 822

EN 12667

EN 826

EN 822

M.U.

-

Thickness of insulation layer 20 - 25,5 - 30 - 40 - 42,5 - 52,5 20 - 30 - 40 - 5020 - 25,5 - 30 - 40 - 42,5 - 52,5 EN 823mm

m

W/mK

kPa

m

Thermal resistance values RD of the insulating boards used depending on the thickness

STIROFLOOR EPS - XPS

ProductSTIROFLEX EPS STIROFLEX EPS STIROFLEX XPS

150 RD

(m2K/W) 200 RD

(m2K/W) - RD

(m2K/W)

Stiroflex 20 20 0,55 20 0,60 20 0,55

Stiroflex 25,5 25,5 0,75 25,5 0,75 25,5 0,75

Stiroflex 30 30 0,85 30 0,90 30 0,90

Stiroflex 40 40 1,15 40 1,20 40 1,20

Stiroflex 42,5 42,5 1,25 42,5 1,25 42,5 1,25

Stiroflex 52,5 52,5 1,50 52,5 1,55 52,5 1,50

STIROFLEX - EPS STIROFLEX - XPS

Packaging inoverlapping rolls

Page 7: The floor heating system with radiant panels

The floor heating system with radiant panels

7Soprema Group

PERIFLOOR

Polyethylene perimeter adhesive tape with closed cells with flashing and precut with the connecting flap in transparent polyethylene, with function of absorption of floor expansions.

Technical properties Norm

Density

Dinamic Rigidity

Compressive strength 25% deform.

Declared thermal conductivity λD at 10 °C

Dimensions

Water absorption after 7 days immersion

DIN 53420 ISO 845

DIN 52214

DIN 53421 ISO 844

DIN 52612 ISO 8301

DIN 53570 ISO 1923

DIN 53433 ISO 2896

PERIFLOOR

20

50

0,02

0,045

Thickness 8 mm - Length 50 m - Height 150 mm

< 2

M.U.

Kg/m3

Mn/m3

N/mm2

W/mK

mm

Vol.%

PERIFLOOR

Roll length (m)Thickness (mm)

508

Tape height (mm) n. rolls/sack m2/sack

150 8 60

EN 82250 m75Length

GEMAFONExtruded expanded polyethylene rolls for under-floor acoustic insulation. They have a yellow colour, with closed cells.

Application

• Acoustic insulation of floating floors

NormGEMAFON STR M.U.GEMAFON STechnical properties

EN 8235 mm5Thickness

EN 822150 mm1500Width

ISO 84520 Kg/m320Density

Length

Width

Thickness

Pitch

1250

750

0,6 - 0,8 - 1,0

50

mm EN 822

mm EN 822

mm EN 823

mm -

Technical properties Shell M.U. Norm

SHELLHigh thickness rigid thermoformed film.

Page 8: The floor heating system with radiant panels

The floor heating system with radiant panels

8Soprema Group

GEMATHERM XC5L GEMATHERM XC7Ln.boards/pallet n.boards/palletThickness Thickness

8 8

5

3

5

3

7

4

7

4

50 50

80

120

80

120

60

100

60

100

m2/package m2/packagem2/pallet m2/pallet

6,00 6,00

3,75

2,25

3,75

2,25

5,25

3,00

5,25

3,00

72,00 72,00

45,00

31,50

45,00

31,50

63,00

36,00

63,00

36,00

GEMATHERM XC5 - XC7

Extruded polystyrene insulating boards, with closed cells, produced with CO2, with a Euro Class E fire behaviour, CE marking according to the Norm EN 13164, EPD/LCA Environmental Declaration and Climate Declaration, with very high compressive strength for heating with radiant floors in industrial underfloors (500 kPa- 700 kPa)

GEMATHERM - XC5L: compressive strength ≥ 500 Kpa

GEMATHERM - XC7L: compressive strength ≥ 700 Kpa

very highcompressive strength

500kPa

700kPa

XC 7XC 5

Smooth with skinSmooth with skin

Board type L-ship lapped I -square edged D-tongue & grooved

Dimensions

Length (mm)

Width (mm)

Thickness (mm)

Technical properties

Compressive strength

at 10% deformation

Water absorption by immersion after 28 days

Surface finishing

Water absorption by diffusion

Water vapour diffusion resistance µ

Freeze-thaw resistance

W/mK

M.U.

kPa

kPa

Vol. %

-

Vol. %

-

Vol. %

Euro class

EN 12667

Norm

EN 826

EN 1606

EN 12087

-

EN 12088

EN 12086

EN 12091

EN 13501-1 Fire behaviour

Thermal conductivity λD at 10°C

with 25 years aging

Compressive creep

CS(10) 700CS(10) 500

CC (2/1,5/50) 250CC (2/1,5/50) 175

CC (2/1,5/50) 200 •

WL (T) 0,7WL (T) 0,7

WD (V) 3WD (V) 3

150150

FTCD 1FTCD 1

E *E *

50-60 mm 0,03480÷300 mm 0,036

50-60 mm 0,03480÷300 mm 0,036

50 ÷ 300 (±3)50 ÷ 300 (±3)

I - LI - L

XC 7XC 5

1250 (±5)1250 (±5)

600 (±3)600 (±3)

• Thicknesses mm 120 - 140 - 160 * E-d2 for multilayer products

Page 9: The floor heating system with radiant panels

The floor heating system with radiant panels

9Soprema Group

SIRAPOR

White-coloured expanded polystyrene insulation boards, made with virgin polystyrene.They are certified by I.I.P. (Italian Institute of Plastics), according to the Norm EN 13163, with CE marking, EPD Environmental Declaration and Climate Declaration.

NEOSTIR

Grey-coloured expanded polystyrene insulation boards, Class 100 and 150 RF, with improved lambda over the usual EPS, according to the Norm EN 13163, with CE Marking.

Class

Dimensions

1000 - 2000 - 4000 1000 - 2000 - 2900

Dimensions SIRAPOR NEOSTIR

Length (mm)

500 - 1000 - 1200 500 - 1000 Width (mm)

20 ÷ 300 20 ÷ 300 Thickness (mm)

Technical properties NormM.U.SIRAPOR NEOSTIR

Water vapour diffusion resistance µ

Dimensional stability at 70°C for 48 h

Compressive strength at 10% deformation

Thermal conductivity λD

at 10°C

Cohesion

Fire behaviour

- Thickness

- Length

- Width

Regulation of products IIP-UNI involves taking direct samples to customers.

Climate Declaration EPDCLIM

ATE D

ECLARATION - ISO 14025

LCA - LIFE CYCLE ASSESSMEN

T

200150 150100 10070

40-10030-70 30-7030-70 30-7020-40

CS (10) 200CS (10) 150 CS (10) 150CS (10) 100 CS (10) 100CS (10) 70

0,0330,034 0,0310,036 0,0310,039

DS (70,-) 1DS (70,-) 1 DS (70,-) 1DS (70,-) 1 DS (70,-) 1DS (70,-) 1

TR 300TR 200 TR 200TR 150 TR 150TR 100

EE EE EE

T2 (±2)

T2 (±2)

T2 (±2)

T2 (±2)

T2 (±2)

T2 (±2)

L3 (±0,6)

L3(±0,6)

L3(±0,6)

L3(±0,6)

L3(±0,6)

L3 (±0,6)

W3(±0,6)

W3 (±0,6)

W3 (±0,6)

W3(±0,6)

W3(±0,6)

W3 (±0,6)

EN 12086-

EN 826kPa

EN 12667W/mK

EN 1604%

EN 1607kPa

EN 13501-1Euro class

EN 823mm

-

EN 822%

EN 822%

Page 10: The floor heating system with radiant panels

The floor heating system with radiant panels

10Soprema Group

TMS® is an insulation product with ACERMI (France) certificate and Marking

Advantages

TMS®is interlocking milled on all four sides: in this way thermal bridges are limited. Pontage on adjacent board joints is not bonded.

TMS® is a board with high rigidity and density: this allows an easier cut, limiting dust and trash in building sites.

TMS® has French Classification SC1 a2 Ch: suitable for installation in all loading repartition caps and with all heating systems.

TMS® surface coatings are resistant to steam.

TMS® is flat and rigid: this facilitates the movements in building sites and the installation is quick, thanks to simplified interlocking on all fours sides.

TMS® is screen-printed on squares of 10 cm. to facilitate cutting, the tile pattern and laying of heating elements.

TMS® has got good thermo-acoustic performances (see adjacent table according the French Norm).

TMS® has the best thermal conductivity and the best performance/thickness ratio in the market.

TMS® CHARACTERISTICS

THICKNESS 25 30 40 48 52 56 68 80 100 120

Thermal resistance RD (m2.K/W)

1,00 1,30 1,85 2,20 2,40 2,60 3,15 3,70 4,65 5,55

Specifications for ground application

SC1 a2 Ch for thicknesses 21-120 mmSC1 b1

for thicknesses 21-100 mm

Critical resistance to compression

Rcs = 105 kPa

Min./max. ds1,3 % / 1,7 % for thicknesses 25 and 30 mm

1,3 % / 1,6 % for thicknesses 40 and 120 mm

ACERMI certification n° 08/006/481

Dimensions (length x width): 1200 x 1000 mm Squares of 10 cm with grooves on 4 sides

A product with exceptional technical and economic advantages

THERMO-ACOUSTIC INSULATIONTMS®

56 mmTMS®

120 mm

TMS®

48 mmTMS®

100 mm

+ Vélaphone®

Classification (DTU 52.10) SC1 a2 Ch SC1 a2 Ch SC2 a4 A Ch SC2 a4 A Ch

Impact noise reduction: ∆Lw 18 dB 19 dB 20 dB 22 dB

Air noise reduction: Rw (C ; Ctr)

∆(Rw + C)58 (-2 ; -7) dB

+ 6 dB57 (-2 ; -7) dB

+ 5 dB59 (-2 ; -8) dB

+ 7 dB61 (-3 ; -10) dB

+ 6 dB

THERMO-ACOUSTIC PERFORMANCESSingle or associated with a sub-thin layer of acoustic Vélaphone® range, TMS® ensures thermal and acoustic comfort on slabs as written in the table below

These solutions improve the acoustics by reducing impact noise transmission and air noise in individual houses or group homes

TECHNICAL TIPSCutCuts are made with usual cutting instruments

LayingThe panels are laid with staggered joints, interlocking them each other to limit the thermal bridges. Plumbing or heating coils are mounted directly on the panels. Provide for joints pontage with a waterproof adhesive in the case of underfloor heating systems.

Vertical jointsPut on the perimeter of vertical walls a polyethylene peripheral adhesive strip Efirive before the laying of TMS® panels on the horizontal floor.

TMS

TMS is a polyurethane foam consisting of a multilayer coating on both faces, screen-printed with a 100 mm pitch to facilitate the eventual installation of the pipe, for thermal insulation with radiant floor or on a floating pavement.

Application

• thermal insulation underfloor

Page 11: The floor heating system with radiant panels

The floor heating system with radiant panels

11Soprema Group

VELAPHONE FIBRE 22Anti-impact noise sound insulation in rolls for underfloor, consisting of a polyester fiber coupled with a bituminous support, with CSTB Certificate - thin acoustic substrate (France).

Application

• Residential underfloor

Advantages

• Excellent levels of acoustic antic-impact noise insulation

• High resistance to walkability and tear

• Quick and easy installation

• Rotproof

• Easy to cut and useful for any kind of surface

• Possibility of outdoor storage

Adaptation phase and cut of the roll Pallettized rolls for outdoor storageRealization of vertical turn

Technical data and packaging

Anti-impact noise reduction index ∆Lw

Thickness (mm) Lenght (mm) Width (m) m2/rollN. rolls/pallet

m2/pallet

Dimensions pallet (cm)

Weight/roll (kg)

22 dB Norm EN ISO 140-8

3,3 20 1 20 16 320 113x113x120 ca. 13

Note: directions and information on the characteristics and tips for installation of our products, while reflecting the tests performed and the most recent technological know-how, cannot be regarded as a guarantee on the desired final result. Therefore the user should check, assuming the

consequent and exclusive responsibility, the compatibility of the products ordered with the intended use and their proper installation, in order not to impair its performance. For more information, please contact our Customer Service.

Page 12: The floor heating system with radiant panels

Sirap Insulation s.r.l.Commercial andaccounting dpt.

via Kennedy, 5425028 Verolanuova(BS) - Italia

T. +39. 030.9368.342F. +39. 030.9368.257

www.sirapinsulation.com

Orders processing dpt.

25028 Verolanuova(BS) - ItaliaT. +39. 030.9368.625F. +39. 030.9368.626

33078 S. Vito al Tagliamento(PN) - ItaliaT. +39. 0434.849723F. +39. 0434.85285

Production plants

via Kennedy, 48/5025028 Verolanuova(BS) - ItaliaT. +39. 030.9368.690F. +39. 030.9368.626

via Forgaria, 9 - z.i. Ponterosso33078 S. Vito al Tagliamento(PN) - ItaliaT. +39. 0434.849711F. +39. 0434.85285

ing

lese

- 2

K /

E1 /

Giu

gn

o 2

016

Visit our website


Recommended