4
The Seetru Change-Over Valve - Switch Over between parallel safety valves without interrupng operaon. Used when plant shutdown is impossible or undesirable Visit Our Website: www.seetru.com Features & Benefits: Designed in accordance with BS EN 378 Pressure drops with 10.0 mm bore SRV in accordance with BS EN 13136 Compact and easy to use design Seat leakage beer than Class V (IEC60534-4) Ventable outlets for safe removal of safety valves Lockable handle (oponal padlock available) Impossible to isolate both safety valves Designed for ease of maintenance, and failsafe correct assembly Robust Construcon Broad Compability Can be fied with a Bursng Disc • Patented Design Can be supplied degreased for oxygen
Transcript
Page 1: The Seetru Change-Over Valveour change-over valve to be fittedto a wide variety of systems. Two relief valves must be fitted to the COV10 before operating the change-over mechanism,

The Seetru Change-Over Valve- Switch Over between parallel safety valves without interrupting operation. Used when plant shutdown is impossible or undesirable

Visit Our Website: www.seetru.com

Features & Benefits:• Designed in accordance with BS EN 378

• Pressure drops with 10.0 mm bore SRV in accordance with BS EN 13136

• Compact and easy to use design

• SeatleakagebetterthanClassV(IEC60534-4)

• Ventable outlets for safe removal of safety valves

• Lockablehandle(optionalpadlockavailable)

• Impossibletoisolatebothsafetyvalves

• Designed for ease of maintenance, and failsafe

correct assembly

• RobustConstruction

• BroadCompatibility

• CanbefittedwithaBurstingDisc

• Patented Design

• Can be supplied degreased for oxygen

Page 2: The Seetru Change-Over Valveour change-over valve to be fittedto a wide variety of systems. Two relief valves must be fitted to the COV10 before operating the change-over mechanism,

Overview:

This valve is used if a plant shutdown is impossible or undesirable for process, engineering or commercial reasons. With change-overvalvesitispossibletoswitchoverbetweenparallelsafetyvalveswithoutinterruptingoperation,sothatmaintenance work can be carried out on each safety valve in turn.

Operating Instructions

Quality & Approvals

InstallationO&MInstructions

TechnicalInformation

Media

Literature Downloads

Recruitment

About Us

Our Distributors

Enquiry FormSeetru Limited, Albion Dockside Works, Bristol, BS1 6UT, England.

website: www.seetru.com |tel:+44(0)1179306100|email:[email protected]

Product Specifications: Adaptor Options:

TheCOV10hasbeendesigned tobeasefficientaspossiblewhile delivering the same robust and reliable constructionyou have come to expect from Seetru. To complete the unit, Seetrusupplyarangeoffittingsandadaptorswhichallowforourchange-overvalvetobefittedtoawidevarietyofsystems.

Two relief valves must be fitted to the COV10 before operating the change-over mechanism, one duty and one standby.

To change over from a duty to a standby safety relief valve (SRV): -

1. Unlockhandleiflockingdevicefitted(recommended).2. StartinginamotionawayfromthedutySRV,rotatehandlethrough180°,eitherclockwiseoranticlockwisedependentuponstartstartingposition.3. Oncefullyrotated,lockinpositioniflockingdevicefitted(recommended).4. IfthenowstandbySRVistoberemove:withcaution,un-tightenventnutofstandbyChange-overarmby1to2revolutionstoexhausttrappedfluidfrom

change-overarm.5. Oncetrappedfluidhasde-pressurised,re-tightenventplugwithatighteningtorqueof3.0Nm.6. Remove the standby SRV.7. Theusermayplugthevacantoutletifdesired,howeversufficientsafetyprocedures(forexampleLockoutTagout)mustbeinplacetopreventinadv

inadvertentchangeover,thusrenderingthesystemun-protectedagainstexcessivepressure.Iftheoutletisplugged,ventarmofpressure,aspreviouslydescribed, prior to removal.

System Connections - ½” to 1” BSP, BSPT & NPT

Valve Connections: - ½”NPTor3/4”BSP(withorwithoutorienta-

tors)Change-Over Valve Kv: - 10.0(Cv=11.5)

Materials of Construction: - Stainless Steel with either Carbon or Stainless Steel

Adaptors / Orientators

Seat Material: - 25%CarbonfilledP.T.F.E.

Temperature: - -196°Cto200°C

Max Design Pressure: - 75barg.

Material Certification: - BSENISO102043.1Pressure Retaining Parts

(OptionalExtra)

Safety Valve Orifice Size: - Upto10mm(FullLiftType)

Maximum Safety ValveSet Pressure:

- 75.0barg.

Page 3: The Seetru Change-Over Valveour change-over valve to be fittedto a wide variety of systems. Two relief valves must be fitted to the COV10 before operating the change-over mechanism,

Materials Of Construction

This valve is used if a plant shutdown is impossible or undesirable for process, engineering or commercial reasons. With change-overvalvesitispossibletoswitchoverbetweenparallelsafetyvalveswithoutinterruptingoperation,sothatmaintenance work can be carried out on each safety valve in turn.

Other Products & Services:

Seetru Products

• Safety Relief Valves

• Stock Safety Valves (QuickDelivery)

• LGS® Safety Valves (Liquid,Gas&Steam)

• Auxiliary Valves

• Liquid Level Contents Gauges

• Window Sight Glasses

Quality & Approvals

InstallationO&MInstructions

TechnicalInformation

Media

Literature Downloads

Recruitment

About Us

Our Distributors

Enquiry Form

Flanged Safety Valves

A comprehensive range available

through our sister company Leser UK

Please visit the LESER Website:

www.leser.com

Contact LeserUK

Seetru Engineering Services

• SafetyValveTesting&Certification

• On-SiteServices

• TruTest®In-SituValveTesting

• SafetyValveReconditioning

Visit the SES Website to view all services:

http://ses.seetru.com

Seetru Limited, Albion Dockside Works, Bristol, BS1 6UT, England.

website: www.seetru.com |tel:+44(0)1179306100|email:[email protected]

Example of COV10 with Inline Valve

1 Components Materials

2 InletOrientator St.Stl

3 COV10 St.Stl / PTFE

4 RP10 Valve SafetyValve&MaterialsToSuitApplication


Recommended