+ All Categories
Home > Documents > Thermal-Driven 3D Floorplanning using Localized TSV Placement

Thermal-Driven 3D Floorplanning using Localized TSV Placement

Date post: 30-Dec-2015
Category:
Upload: consuelo-azura
View: 67 times
Download: 0 times
Share this document with a friend
Description:
Thermal-Driven 3D Floorplanning using Localized TSV Placement. Puskar Budhathoki , Andreas Henschel and Ibrahim (Abe) M. Elfadely IC Design & Technology (ICICDT), 2014. I. INTRODUCTION II. MOTIVATION III. PROBLEM FORMULATION IV. METHODOLOGY V. RESULT AND DISCUSSION - PowerPoint PPT Presentation
15
Thermal-Driven 3D Floorplanning using Localized TSV Placement Puskar Budhathoki, Andreas Henschel and Ibrahim (Abe) M. Elfadely IC Design & Technology (ICICDT), 2014
Transcript
Page 1: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

Thermal-Driven 3D Floorplanning using Localized TSV Placement

Puskar Budhathoki, Andreas Henschel and Ibrahim (Abe) M. Elfadely

IC Design & Technology (ICICDT), 2014

Page 2: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

I. INTRODUCTION II. MOTIVATION III. PROBLEM FORMULATION IV. METHODOLOGY V. RESULT AND DISCUSSION VI. CONCLUSIONS

Page 3: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

INTRODUCTION The complexity of physical design increases

with the exponential growth of circuit. 3D integration technology is a promising

technique to boost performance and reduce wirelength.

However, the critical challenge in 3D IC is thermal management.

Page 4: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

MOTIVATION Goplen et al [6] indicates that thermal TSVs

constitute an important path for vertical heat flow.

Lee et al [7] studies arrangement of thermal TSVs in multichip modules packaging and found that heat removal is directly proportional to the size of thermal via islands

Page 5: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

PROBLEM FORMULATION

multi-objective optimization problem, minimizing the occupied area of the floorplan (A), total wirelength (w) and number of signal TSVs ()

Page 6: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

METHODOLOGY Placement of thermal TSVs considers both

thermal effect as well as area impact of thermal TSVs.

Page 7: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

design flow

Page 8: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

A. Floorplanning A very recent CBL based floorplanning tool

(Corblivar [9]) is employed as floorplanning module which accounts for optimization of chip area, wirelength, and interconnects as well.

Page 9: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

B. Floorplanning/Thermal Management Interface This module converts CBL tuples and global

alignment sequence into Cartesian coordinates and generates an output format readable by the thermal simulation module.

Page 10: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

C. Thermal Simulation The HotSpot extension tool presented in [10]

allows modeling of thermal TSVs with related thermal resistivity and specific heat capacity values in specified (delimited) regions.

Page 11: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

D. Thermal Constraint Assessment and TSV Placement An iterative greedy approach is used in a grid

cell having maximum temperature and thermal TSVs are placed in passive substrate and bonding layer until the maximum temperature of each grid cell is below the predefined target temperature.

Page 12: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

is the previous conductivity of the grid cell, is the current temperature and is the target maximum temperature of the whole package chip.

is the maximum allowable TSV density in each grid cell, c is a user specified constant and is the thermal conductivity of TSVs.

Page 13: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

RESULT AND DISCUSSION

Page 14: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

RESULT AND DISCUSSION

Page 15: Thermal-Driven 3D  Floorplanning  using  Localized TSV  Placement

CONCLUSIONS Experimental results show that our approach

can optimize interconnect wirelength, chip area, number of TSV and hotspot temperatures simultaneously.


Recommended