Now the Success® Injection System can inject Thermoflex™ acetal resin. Simply purchase a Success® adopter kit. No cartridge required!
Thermoflex™ acetal resin delivers 19 tooth colors, 3 tissue colors, excellent retention and durable performance.
Complete Laboratory Solutions
Success® FRS Injection System
Thermoflex™ Acetal Resin for Tooth-Colored Clasp
Lucitone® 199 High Impact Denture Base
Biosil ® f Cobalt Chrome RPD Alloy
Lucitone® 199 High Impact Denture FRS Denture
High ImpactSuperior Strength
No Beryllium, No NickelBiocompatiableResilence Cobalt Chrome Alloy
QC-20 PermaSoft ® Soft Denture Liner
Triad Material Isolant
For injecting acrylic and FRS denturesUltra-high impact denture base resinPourable resinFRS flexible denture fabricationTooth-colored clasp Quick cure denture base acrylic for aesthetic full and partial denturesSelf-Cure acrylic repair material Durable silicone based soft liner. (Used either on clinical or lab sides)VLC material for various indicationsSelf-curing orthodontic resin for the preparation of removable orthodontic appliancesSeparating solutionAll purpose modelling and base-plate waxCobalt Chrome RPD alloy
Success ® FRS Injection SystemLucitone ® 199Lucitone ® Fas-Por Lucitone ® FRS MaterialThermoflexTM Acetal Resin QC 20Rapid Repair PermaSoft ® Soft Denture Liner TriadOrthresinIsolantModeling waxesBiosil ® f
Dentacryl® Shade Guide in an attractive presentation plastic holder is suitable for reference use in both the Dental Surgery and in the laboratory. Available in nine popular shades.
TeethA natural looking tooth in popular moulds and shades. Modern production techniques resulting in quality products. Built-in fluorescence - just the same as natural teeth. Auto-setting posteriors G,K, and O for easier articulation.
This system uses novel Biomechanical concepts to fulfill the desire, voice by many patients, for the best possible reconstruction of their original physiognomy and their natural speech pattern. It helps create high-quality “Comfort dentures” with excellent aesthetics, phonetic and functional properties, restoring the patients’ quality of life.
The positional stability of the denture on its denture bed is also greatly improved. Pressure sores - and the ensuring need for denture adjustment at chairside - are reduced to a minimum.
Freely interacting articulation concept.
Performace
FE-Set-up System
ConventionalAcrylic Material HXL Material
Single CrossLinked Polymer
Double CrossLinked Polymer
Shade conversion chart
Dentacryl®
HXL Material
Shade System
And unlike the normal acrylic teeth, HXL teeth are able to mimic the gradual wear of tooth enamel, while delivering outstanding occlusal integrity and long-lasting aesthetics.
The low wear feature is due to a proprietary chemistry that employs an complex polymer. This is formed with highly double cross link call “HXL”.
15B4
01 02 03 04 05 G4 G6 G8A1 A2 A3 A3.5 A4 B1 B2 B3Vita
Dentacryl® HXL
Natural fluorescence even under ultra-violet light, which means better aesthetics than other acrylic teeth.
Precision moulded and hand finished to give superior strength and durability.
Special posteriors SA and SB have freely interacting cusps. Whether on a fixed articulator or a fully adjustable articulator a well balanced occlusion is more quickly achieved.
3 types of posterior mould available in graduated sizes with a natural buccal contour and a reduced basal profile. This keeps bulk and grinding to a minimum.
Dentacryl® HXL have Special Incisal Blending.
Far exceed international as well as British Standards (B.S. No. 3990 and ISO No. 3336.)
This mold chat is in accordance with ISO3336
Posteriors
Articulation TableUPPER LOWER TRAD AUTO SPECIAL
4 21 AA G SA/SB7 31 AA G SA/SB8 51 AB K14 41 AB/AA G/K SA/SB16 41 AB/AA G/K SA/SB18 51 AB/AC K/O20 61 AC O30 51 AB/AC K/O34 75 AB O36 75 AB K/O37 91 AD O38 75 AC/AB O40 91 AD O48 51 AB K/O52 91 AD G/O
Traditional Autoset Special
Dentacryl® HXL (100% Highly Crossed Linked)
45.2 9.5 8.25
A B C
31.2 8.25 4.5
33.0 9.0 5.1
32.4 9.0 4.9
34.4 9.5 5.4
35.9 9.75 5.6
34.0 10.25 4.9
38.6 11.75 5.6
42.9 10.0 7.9
49.4 11.5 9.0
47.7 10.5 8.6
43.9 10.25 8.25
44.6 10.5 8.0
49.4 12.25 9.0
45.0 10.0 8.1
39.5 8.5 7.6
42.2 10.0 7.75
46.9 10.5 8.5
54.0 12.5 10
42.8 8.2 7.7
43.5 10.0 8.1
51
3051
91
21
41
51
91
61
75
75
91
51
31
41
75
47.9 10.75 8.8
The measurements indicated under each mould number are in millimetres. A, the width of the set of 6 (flat) B, the length of the central (minus neck)C, the width of the central.
The Posterior mould measurement indicates the mesio-distal dimension in millimetres of the four left upper teeth (D)
UpperAnteriors
LowerAnteriors
Posteriors
28.9 Special
Special30.2
31.4
33.2
29.75
30.0
31.8
Upper Anteriors Lower AnteriorsTraditional Mould
Autoset Mould
Special Mould
The principle of natural aesthetic harmony between face form and maxillary anterior tooth arrangement supports that there are four basic form classifications observed in nature. This theory has been well demonstrated by clinical research and extensive application in many private dental offices. For each of these categories, there is a workable corresponding basic anterior tooth arrangement.
Similarly, modifications appearing in the basic face form may be reflected by corresponding modifications in the anterior arrangement. The Dentacryl® mould system incorporates the aesthetics principle into each lifelike mould form which replicates human dentition.
Below, we describe and illustrate the four face forms. A suggested procedure is to use the Trubyte Tooth Indicator (#98981, pictured at left) to classify the patient by face form.
Trubyte classifies these forms even more stringently into seven category breakdown for even finer patient facial definition as demonstrated in the Mould Chart to follow.
In the Square Face, the sides of the face from the hairline to the levels of the condyles to the angles of the jaw are straight and parallel.
The Square Face
In the Square Tapering Face, the sides of the head are parallel from the condyles upward. From the condyles downward along the sides of the face, the outline tapers in to the angles of the jaw.
The Square Tapering Face
The Ovoid Face is widest through the center at the level of the condyles. It curves upward and downward to form an oval outline.
The Ovoid Face
The Tapering Face is widest at the hairline and narrowest at the angels of the jaw. The lines converge in toward the jaw.
The Tapering Face
Basic Facial FormsTrubyte Tooth Indicator
A B C D D
SA
SB
21
31
41
51
61
75
91
52
8
4
16
18
37
20
34
36
40
48
7
14
38
AA
AB
AC
AD
G
K
O
- Dentacryl ® HXL Posterior AA/AB/AC/AD is functional cusp inclination- Dentacryl ® HXL Posterior G/K/O is 10-12o cusp inclination- Dentacryl ® HXL Posterior SA/SB is 0-5o cusp inclination