+ All Categories
Home > Documents > TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Date post: 16-Jan-2016
Category:
Upload: claude-jennings
View: 213 times
Download: 1 times
Share this document with a friend
34
TRANSPORTABLE STAND ALONE TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR MULTIGAS DETECTOR BM 25 BM 25
Transcript
Page 1: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

TRANSPORTABLE STAND ALONE TRANSPORTABLE STAND ALONE MULTIGAS DETECTORMULTIGAS DETECTOR

BM 25BM 25

Page 2: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

STAND ALONE DETECTOR:

BM25BM25• Rugged

• Has been specially designed for operation in harsh and corrosive environments

• High visibility and audible alarm• Fitted with a large flashing red LED

module • and 2 « loud hooters » : 103db/1m.

Page 3: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Safety in the field

• Designed for team protection:rescue teams…

• Area surveillance for mobile or short term works

• Used where fixed detection systems are inapropriate or not present

Page 4: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25 = rugged MX 2100 version

• Keep the MX2100 characteristics and other new functions :

• a new king of cells «serie 7/3 » • programmable relay outputs «gas and

fault alarms  »• 2 programmable 1/0 inputs• charger input• Trickle charge in EX areas• Safety perimeter

• RS485 or radio communication outputs ; (new developments).

Page 5: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25: description

Red flashing beacon(protected)

Loud hooters

protected buttons

2 connectors(outputs) on each

side of casing

LCD display

Carrying handle

sensors

Sizes:467x195x180mm (H P L)

Weight : 6.8 kgsIP 66

Page 6: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25: description

Page 7: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 :external connectorsright side

Left side

Relay outputs (default and gas) and 2 logic inputs (remote acknowledment and remote alarm)I/O RS485 (new development)

Charger (230ACVor 12 to 30 DCV)

Trickle charge input

Page 8: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Example of remote alarmExample of remote alarm 0 % CH4

GASGAS

ALARME1 20.9 % O2

15 : 05 : 290 ppm CO 0 ppm H2S

20.9 % O2

AL. TRANSFERT 0 ppm CO 0ppm H2S Message of remote

alarm

Page 9: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

GAS AL

STRAIGHT FORWARD

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarm transfert : activated

AL. TRANSF

Junction box

Page 10: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

STRAIGHT FORWARD

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarm transfert : activated

GAS ALAL. TRANSF

x

Page 11: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

AL. TRANSF

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarm transfert : activated

GAS AL

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

Page 12: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

AL. TRANSF

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

GAS AL

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

ACKNOLEDGEMENT

Page 13: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

Page 14: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF To acknowledge :

1/ open the loop

2/ acknowledge each BM25

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

Page 15: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

GAS AL

STAR INTERCONNECTION

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

GAS AL

AL. TRANSFERT

Page 16: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

AL. TRANSFERT

TREE INTERCONNECTION

Max. BM25 connected : 3 + 1

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

GAS AL

AL. TRANSFERTAL. TRANSFERT

Page 17: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Example of remote alarmExample of remote alarm ( logic inputs)

0 % CH4 20.9 % O2

AL. TRANSFERT

0 ppm CO0 ppm H2S

« manual call point »FUNCTION

Page 18: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : batteries

• Pack of NiMH batteries (7V2/9AH), rechargeable without opening

• Autonomy = according to the configuration :

• Up to 170h operations non-stop

• Or for example 90 hours with explo/O2 and 2 toxic cells.

• Recharged in less than :4h30mn.

Page 19: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : remote power supply

• It’s possible to trickle the BM25 in a classified zone linked with «a remote intrinsic safety power  » (with flammable and toxic cells only)

• For these reason,in this case and without alarm, the BM25 will work practically indefinitely !!

• But with alarm triggering,batteries will be discharged a bit.

Page 20: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Remote power supply in a Remote power supply in a classified zone classified zone

Intrinsically safe remote

power supply

ZONE 0

Zone 0 Safety zone

BM 25

Page 21: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: smart blocks• 1 and 2= mini toxic or O2

smart block of cell• 3= médium toxic or O2 • 4= EXPLO smart block

of cell• 5= médium or series 3/7

(new developments).

4 1

2

35

Note: without a block somewhere, take in place adummy cell to keep the index of protection (IP66).

Page 22: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: smart blocks• All the cells are:

• « plug in » easy connexion

• smart because fitted with a memory of characteristics (type of detected gas, unit, scale, sérial number, usure rate etc…

• Pre-calibrated

• Interchangeable.

Page 23: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: smart blocks• Channel 5 can be fitted

with either a medium cell or a big model (series 3)

• Note: BM 25 is fitted with 5 channels but can make a gestion of 4 only!

• For this reason if you use the channel N° 5, the 1 st will be automatically inhibited and the cell deactived !

4 1

2

35

Page 24: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: explosible smart-blocks

• This channel is obligatory connected with a flammable cell for detection of major explo.gas and 2 types of cell can be used :

• catalytic or• catalytic/catharometric .

Page 25: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: explosible smart-blocks

• « universal »: catalytic cell

• Scale of measurement = 0 to 100% LEL

• « Non ambiguity measurement message » if the signal is tooà high > 100% LEL

• Choice of detected explo. gas (preprogrammed list)

• choice of a special type « all the gas »: the new cell, recently developped by Oldham, will indicate a correct concentration of the explo. gas detected whatever the type and in spite of a unic calibration with CH4 (different curves of explo. gases are very closed).

• catalytic/catharometric cell:

• Scale of measurement = 0 to 100%LEL / 0 to 100% gas/ volume with an automatic commutation of scale

• Note: to use this « LEL/volume » version, it’s obligatory to equip the BM25 with an oxygen cell !

Cellule explo classiqueLEL

Reading

100%

50%

0%

CH4

Butane

H2NH3

GPL

LEL

10% Max.

Page 26: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25:avaible smart blocksBM25:avaible smart blocks

Page 27: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 OPTIONS

Page 28: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : pumping system

• Avaible in option: the BM25 can be fitted with an included electric pump

• Associated with a remote sampling system (cap of cells and different king of probes)

• automatic working pump if a cap fixed….

gaz

Page 29: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Optical IR linking Optical IR linking forfor COM 2100 COM 2100

• An IR port located on the right side of BM25 allows the linking to a PC

• serial RS232 or USB cables are avaible 

• COM 2100 software will recognize automatically a linking to a BM25 or to MX2100

• common software MX2100/BM25.

Page 30: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

modules of communicationmodules of communication

• Each following modules wil be installed on demand in the instrument, outputs will be avaible on right side:

• RS485• 4 to 20 mA• CATEX ( TOTAL)• Others on demand ….

Page 31: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25 in the field = example of option (legs)

Semi-portable or permanently installed

Page 32: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : CERTIFICATIONS : CERTIFICATIONS

• BM25 (fitted with cells) it’s approved intrinsically safety category 1 category 1 (very high level of safety)

• So usable in zones 0 ! usable in zones 0 !• ATEX II 1 GD EEx ia IIC T4 (except with CO2)

• ATEX I M1 (mines)• Other certifications running: INDIA,

RUSSIA, CHINA …

Page 33: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 = very high level of = very high level of safety !safety !

• The BM25 BM25 is a is a Categorie 1 instrument Categorie 1 instrument and can be used in zones zones 00 and directly in the tank

• Using without sampling systems

• And with remote informations of alarms…

Page 34: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : examples of : examples of applicationsapplications

• industrial and maintenance sites

• for manipulations of dangerous substances

• chemical fire brigades

• in tunnels, in confined spaces , in sewers …

• wastewater stations

• Aircraft maintenance workshops

• Coal mines

• In storage tanks, underground storage tanks…


Recommended