+ All Categories

Tray

Date post: 30-Nov-2015
Category:
Upload: ragkiran
View: 60 times
Download: 1 times
Share this document with a friend
Description:
construction
Popular Tags:
35
Introduction: Once the process design stage ends, the equipment design begins. This stage of design converts process requirements into actual hardware. One of the most prominent hardwares used for mass transfer is tray. Tray columns are widely used in various types of mass transfer operations. All the simulation results, which predict a certain number of theoretical stages, can be converted to actual trays depending upon tray efficiency for a particular service. In any conventional tray vapour rises through the liquid pool on the tray deck and then disengages from the liquid in the space above the deck. Liquid enters the tray from a downcomer above and leaves via a downcomer below. Conventional Tray has three functional zones: Active area for mixing vapour and liquid: This is the zone where mass transfer occurs. Vapour space above the active area: This is the zone in which liquid is separated from vapour. Downcomer between trays. This zone has two functions, first moving liquid from one contacting tray to another and second disengaging vapour from liquid. Each of these zones takes up vertical and horizontal space in the tower. Selection Guide for Tray Column:
Transcript
Page 1: Tray

Introduction:

Once the process design stage ends, the equipment design begins. This stage of design converts process requirements into actual hardware.

One of the most prominent hardwares used for mass transfer is tray. Tray columns are widely used in various types of mass transfer operations. All the simulation results, which predict a certain number of theoretical stages, can be converted to actual trays depending upon tray efficiency for a particular service.

In any conventional tray vapour rises through the liquid pool on the tray deck and then disengages from the liquid in the space above the deck. Liquid enters the tray from a downcomer above and leaves via a downcomer below.

Conventional Tray has three functional zones:

Active area for mixing vapour and liquid: This is the zone where mass transfer occurs.

Vapour space above the active area: This is the zone in which liquid is separated from vapour.

Downcomer between trays. This zone has two functions, first moving liquid from one contacting tray to another and second disengaging vapour from liquid.

Each of these zones takes up vertical and horizontal space in the tower.

Selection Guide for Tray Column:

The factors discussed below influence the choice between trays & packings. As these are guidelines for selection of trays or packings for a particular service, it is recommended to analyze each design case on its own merit for selection.

Sr. No.

Page 2: Tray

System Favouring Tray Column System Favouring Packed Column

1

Solid handling Vaccum system

2

High liquid rate Low pressure drop application

Feed composition and

temperature

Revamps- The pressure drop

reduction

3

can be translated into capacity gain,

an

variable

energy gain or separation improvement.

4

Large diameter columns Small diameter columns< 900 mm

5

Page 3: Tray

Performance prediction is easy Corrosive system

6

Less weight saving in cost

of

Foaming system

foundations and supports

7

Interboilers, intercondensers, cooling Low liquid holdup for

reducing

colils, & side draw polymerisation and degradation.

8

High turn down requirements Batch Distillation

9

Chemical reactions

The industry, based on its experience, has standardised the type to be used in certain services. If this reference is not available the guideline as per Appendix 1 are to be used

Types of Tray

Page 4: Tray

The particular tray selection and its design can materially affect the performance of a given distillation, absorption, or stripping system. Each tray should be designed so as to give as efficient a contact between the vapour and liquid as possible, within reasonable economic limits.

Valve tray:

Valve trays are perforated sheet metal decks on which round, liftable valves are mounted. The vapour flows through valves which are installed parallel to the outlet weir. Valve trays combine high capacity and excellent efficiency with a wide operating range.

Advantages:

Excellent liquid/ vapour contacting.

Higher capacity.

Higher flexibility than sieve trays.

Can handle higher loadings.

Low-pressure drop than bubble cap.

Sieve tray:

Sieve trays are flat perforated plate in which vapour rises through small holes in tray floor, & bubbles through liquid in fairly uniform manner. They have comparable capacity as valve trays.

Advantages:

Page 5: Tray

Simple construction Low entrainment,

low cost Low maintenance cost

Low fouling tendency

Disadvantages:

Less-flexible to varying loads than

other two types

Bubble cap tray:

Vapour rises through risers or uptakes into bubble cap, out through slots as bubbles into surrounding liquid on tray. It is mainly used in special applications.

Advantages:

Moderate capacity

Most flexible (high & low vap. & liquid rates)

Can provide excellent turndown.

Disadvantages:

High entrainment, High fouling tendency

High cost,

High pressure drop

Dual flow trays:

A dual flow tray is a sieve tray with no downcomers. This tray operates with liquid continuously weeping through the holes. Due to the absence of downcomers, dual flow tray gives more tray area hence a

Page 6: Tray

greater capacity than any of the common tray types. They are ideal for revamp where if some efficiency can be sacrificed for more capacity. They are least expensive to make and easiest to install and maintain.

Dual Flow Tray Baffle Tray

Baffle trays:

For a baffle tray column the gas flows upwards through the baffle openings and in doing so contacts the liquid showering down from one baffle to the next. Baffle tray columns have almost same flooding capacity as cross flow trays. Types of baffles used are disc & donut and segmental baffles for various column diameters.

Dual flow and baffle trays are used for fouling applications, solid / slurry handling services, corrosive services.

Proprietary types of trays:

MD Trays – Linde / UOP,

Ripple Trays – Stone & Webster Engg. Corp.

Rectangular Valve (BDH),

ValveGrid (MVG/SVG),

SHELL HIFI, ConSep Trays – SulzerBallast Tray,

Flexitray, Bi-FRAC, SUPERFRAC and ULTRAFRAC Trays – Koch-Glitsch Engg.Co., Tunnel Trays- Montz,

Nye trays- Nye Engg Co,

Comparison between Common Conventional Trays.

Page 7: Tray

Sr. Factors Sieve Tray Valve Tray Bubble-Cap Tray Dual-Flow Tray

No.

1 Capacity High High

Moderately High

Very High

2 Efficiency High High

Moderately High

Least

3 Turndown ~50% ~25-30%

10%

Least

4 Entrainment Moderate Moderate

High

Low to moderate

5 Pressure Drop Moderate Moderate

High

Page 8: Tray

Low to Moderate

6 Cost Low ~1.2 times

~ 2-3 times of sieve

Least

sieve trays

trays

7 Maintenance Low Low to

Relatively High

Low

Moderate

8 Fouling Low Low to High: Tends to collect Extremely Low

Tendency Moderate Solids

9 Effects of Low Low to High Very Low

Corrosion moderate

Proprietary, Some information

Design Available.Instability

10 Well Known but readily Well Known

information can occur in large

available

dia. (>8 feet)

Page 9: Tray

Often used Where high Extremely low Liquid Capacity revamps,

Main flow & Where

11 when turndownturndown is Highly fouling and

Application leakage must be

is not critical required corrosive services

minimized

Tray Parameters

a) No. of passes (Np):

The numbers of flowpaths of liquid on tray are 1, 2, 3 or 4 as per liquid capacity requirement of column. From a capacity viewpoint, a liquid rate greater than 6 gpm / inch of weir (weir loading), is the rate at which a higher number of flow paths should be considered. The maximum allowable weir loading is 13 gpm/in of weir length. If the weir loading exceeds this the tray needs redesign with higher number of passes.

b) Tray Spacing (S):

Tray spacing is the distance between two trays. Generally tray spacing ranges from 8 to 36 inches (200 mm to 900 mm). Prime factor in setting tray spacing is the economic trade-off between column height and column diameter. Most columns have 600 mm tray spacing. Cryogenic columns have tray spacing of 200-300 mm.

c) Outlet Weirs (hw):

An outlet weir maintains a desired liquid level on the tray. As the liquid leaves the contacting area of the tray, it flows over the tray weir to enter into the downcomer.

Page 10: Tray

d) Downcomer Clearance (hcl):

This is the vertical distance between the tray floor and the bottom edge of the downcomer apron. The Normalpractice is to use a downcomer clearance of 1/2 inch less than the overflow weir height to provide a static liquid seal

e) Inlet Weirs & Recessed Seal Pans:

Inlet weirs and recessed seal pans are primarily used for achieving a downcomer seal in cases where a potential positive sealing problem exists and clearance under downcomer is limited

f) Downcomers:

Passage of liquid from the top tray to the bottom of tray occurs via downcomers. Downcomers are conduits having circular, segmental, or rectangular cross sections that convey liquid from upper tray to a lower tray in a distillation column.

g) Downcomer width (Chord height, WDC):

It is maximum horizontal distance between tower wall and weir.

h) Flow path length (FPL):

Page 11: Tray

Flow path length is the distance between the inlet downcomer & outlet downcomer. The minimum limit for flow path length is 400 mm in order to provide good contacting between vapour and liquid. This is also necessary for the mechanical reason of providing tray manway.

i) Tray deck thickness (t):

Trays normally used in commercial service need a minimum material thickness to provide structural strength (personnel walk on them during installation) and corrosion allowance. A thickness of 10 to 12 gauge (2.5 to 3.5 mm) is customary for carbon steel, while 12 to 14 gauge (1.9 to 2.5 mm) is used for stainless steel trays (in general no C.A. for SS)

j) Hole pitch (P):

Centre to centre distance between holes is called pitch. Normal practice is to use a hole pitch to hole diameter ratio between 2.2 to 3.8.

k) System (Derating) factors:

Derating factors are often closely related to the foaming tendency of the system. Higher the foaming tendency, the lower is the Derating factor. System factors are used in three of the rating correlations (jet flood, down comer backup flood, down comer choke) to account for system effects on hydraulic capacity limits. It includes both foaming effects and high vapour density.

Page 12: Tray

l) Bubbling (Active) Area (AB):

Bubbling area is the column area, which is actually available for vapour bubbling through liquid. It can be defined as column area minus downcomer areas, downcomer seal & large calming zones.

m) % Hole Area:

This is the ratio of hole area to bubbling area. The default practice is to target a hole area of 8 to 10 % of bubbling area for pressure services. The acceptable range for percentage hole area is 5 % to 15 %. However for some critical services, we can go % hole area up to 17-17.5% provided that weeping is under control. Hole areas below 5 % are not used.

n) Anti jump baffles:

Anti jump baffles plates suspended vertically above centre or off centre downcomers, which stops liquid jumping from one deck onto the opposite deck, flow path

Tray Hydraulic Parameters

Following are the some important output parameters of tray hydraulics.

Page 13: Tray

a) Flood:

Jet Flood:

In spray regime operation flooding is brought about by excessive vapour flow, causing excessive liquid to be entrained in the vapour up the column. In froth and emulsion flows regimes operation excessive froth entrainment in the vapour up the column causes jet flooding.

Down-comer Back-up Flood:

Occurs when the pressure available for a given height of liquid and froth in the downcomer cannot overcome the total pressure drop across the tray This pressure imbalance causes the froth in the downcomer to start backing-up until it reaches the tray above, causing an increased accumulation of liquid on it. It requires high liquid and vapour loads.

Downcomer Choke Flood:

The mechanism by which this type of flooding occurs is one related to frictional pressure losses in the downcomer becoming excessive. In addition, the vapour carried into the downcomer must separate from the liquid and then flow counter-current to the liquid entering the downcomer. When the combination of vapour exiting and the liquid entering becomes excessive, the downcomer entrance is choked causing the liquid to backup on the tray. It requires relatively high liquid rates, surpassing a velocity limitation on the downcomer.

b) Weeping/Dumping

The pressure exerted by the vapour is insufficient to hold up the liquid on the tray. Therefore, liquid starts to leak through perforations.

c) Pressure Drop:

Page 14: Tray

Pressure drop is an important consideration while designing a tray. It becomes more critical for the vacuum systems than the high-pressure systems. The tray pressure drop is viewed as the sum of the pressure drop through the valves or sieves and pressure drop through the aerated liquid on the tray deck.

d) Turndown ratio:

Turndown ratio defines the range of vapour load between which the column can operate without substantially affecting its’ primary separation objective (i.e. fractionation efficiency) or over which acceptable tray performance is achieved. The tray efficiency stays at or above the design value throughout the turndown range.

Tray Sizing

The sizing procedure is an iterative calculation. A preliminary design is set, and then refined by checking against the performance correlations until an adequate design is achieved. The sizing calculations are performed at the point where column loading is expected to be highest and lowest for each section, i.e.,

i) The top tray

ii) Above every feed, product drawoff, or point of heat addition or removal.

iii) Below every feed, product drawoff, or point of heat addition or removal.

iv) The bottom tray.

v) At any point in the column where the calculated vapour or liquid loading peaks

Page 15: Tray

The sizing is done at all above load points and also detailed sizing is checked at all above load points. All design parameters given in the design procedure below are calculated at all above load points at turndown and turn-up loads so that the feasibility of design for varied loads is tested.

a) Preliminary determination of tower area:

The methods used for determining tower diameter are:

“C” Factor Method

Nomograph Method

FRI Tray design handbook

However in this technical guideline we are describing method using C-Factor Method.

C-Factor Method:

The following calculations are done at all the loading points mentioned above and diameters are found separately. If the difference in calculated diameter at different sections exceeds 20 percent, different diameters for the sections are likely to be economical. The section having different diameter should be at least 20ft in length else same diameter can be maintained.

i. Tray Area

Assume appropriate values for following parameters (based on system requirements) for preliminary diameter calculation.

dH = Hole diameter, inches (¼ to ½ inch) S = Tray spacing, inches (18 – 24″)

hct = Clear Liquid height at the transition from the froth to spray regime, in of liquid.

Page 16: Tray

Assumption: The starting values for these can be dH=1/4″, S=24″, h ct=2″

Calculate C-Factor (CSB) using following Kister and Haas Correlation:

ii. Flood Velocity Calculation

This is the velocity of upward vapour at which liquid droplets are suspended. Calculate Flood Velocity (uN) using following equation:

iii. Net Area Calculation

The net area represents smallest area available for vapour flow in the inter-tray spacing. Calculate Net Area (AN) from the flood velocity using following equation: Assume the column is to be designed for 80% of flood.

iv. Downcomer Area Calculation Calculate downcomer area (AD) from clear liquid velocity in downcomer using following formula:

Where,

QL = Liquid Flow Rate, ft3/s

Page 17: Tray

VCL = Clear Liquid Velocity in Downcomer

Value of VCL obtained from table below. No derating factor is required for this calculation, as VCL values have taken care of foaming

Table: Recommended VCL values for different foaming tendencies

Foaming Example

VCL in downcomer, ft/s

18-in

24-in

30-in

Tendency

Spacing

Spacing

Spacing

Low Low pressure (<100-psia) light hydrocarbon, 0.4-0.5 0.5-0.6

0.5-0.6

Page 18: Tray

stabilizers, air-water simulators

Medium Oil systems, crude oil distillation, absorbers, 0.3-0.4 0.4-0.5

0.4-0.5

med. pressure (100-300 psia) hydrocarbon

High Amine, glycerine, glycols, high-pressure 0.2-0.25 0.2-

0.2-0.3

(>300-psi) light hydrocarbons 0.25

v. Tower Diameter Calculation

TotalTowerArea (AT) = AD + AN

b) Preliminary tray layout:

A Preliminary layout is needed as layout influences the column size.

Page 19: Tray

Downcomer Layout:

Check the % of Downcomer area with respect to tower area:

The Fractional area should around 10% but avoid less than 8% in normal circumstances. Note that AD should in no circumstance be less that 5% of AT

Net Area (AN):

The total tower cross-section area AT less the area at the top of the downcomer (sometime refer to as free area, the term free area.)

The net area represents the smallest area available for vapour flow in the inter-tray spacing.

AN = AT - AD

Bubbling (Active) area (AB):

The total cross-section area AT less the area at the inlet & outlet downcomer is called as bubbling area.

AB = AT - ADT - ADB

Page 20: Tray

Below figure shows the Typical Tray Layout.

Weir Length and Downcomer Width: SinglePass Tray:

The calculation of Weir Length and Downcomer Width involves geometrical relationship between downcomer area, downcomer width, and downcomer length.

Following Figure shows downcomer geometry:

Calculate downcomer width and weir length using following method

? = sin-1(h/R)

w = 2*R COS (?) or w = 2*(R2 – h2)0.5

?/2 = ?/2 - ?

Sector area = ASECT = ? R2 * ? / (2 * ?)

Area of triangle (ABC) = ATRI. = w*h/2

Page 21: Tray

Where,

Lw = Weir Length = w* (1-fractional weir blockage)

wdc = Downcomer Width = R -h

AD = Adc = Downcomer Area

Fractional weir blockage is the fraction of total weir length that is available for liquid flow by using picket and fence type of weir. Blocked (Picket fence) weirs are used for handling low liquid loading.

Down-comer area

AD = ASECT- ATRI

Two Pass Tray:

Two pass trays have alternating arrangements of one center-downcomer and two side-downcomers.

The side downcomer area can be calculated as that for single pass tray. It should be noted that side down-comers are on both sides.

Center downcomer calculations can be done as follows in similar manner as side down-comer:

Page 22: Tray

? = sin-1 (h/R)

w = 2*R COS (?1) or w = 2*(R2 – h2)0.5

? = 2*(?/2- ?)

Sector area = ASECT = ? R2 * ? / (2 * ?)

Area of center downcomer = Area of circle -2*area of sector + 2*Area of Triangle Area of downcomer = ?*R2 – 2* ASECT + h1*w1

In case of more than two pass trays we have to define one more parameter, i.e. off-center downcomer location from centerline. This needs to be done on a case-by-case basis.

Liquid Flow Path Length (FPL):

ForSinglePassTray:

FPL= (tray diameter) minus (side DC width of the tray) minus (bottom width of DC of tray above)

Page 23: Tray

Where,

w1dc

=

Downcomer width (Centre downcomer, Bottom of Downcomer)

w2dc

=

Downcomer width (Side downcomer, Top of Downcomer)

w3dc

=

Downcomer width (Centre downcomer, Top of Downcomer)

w4dc

=

Downcomer width (Side downcomer, Bottom of Downcomer)

Page 24: Tray

C) Detailed Design

Flooding Check:

The flooding check is performed using following Correlations:

Kister and Haas correlation.

Downcomer choke-Koch correlation

Fair’s correlation

Smith et al. correlation

1. Jet Flood: Kister and Haas correlation

This correlation possess following advantage:

- It gives a close approximation to the effects of physical properties, operating variable, and tray geometry on the flood point.

- It describes spray regime entrainment.

- It was derived from a much wider database of commercial and pilot-scale column data.

- It can predict sieve and valve tray entrainment flooding within ± 15 and ± 20 percent respectively.

This correlation possess following restriction:

Sr.no. Factors Applicability

Page 25: Tray

1 Flooding Mechanism Entrainment (Jet) flood only

2 Tray Type Sieve or Valve trays only

3 Pressure 1.5-500 psia

4 Gas Velocity 1.5-13 ft/s

5 Liquid Load 0.5-12 gpm/in of outlet weir

6 Gas Density 0.03-10 lb/ft3

7 Liquid Density 20-75 lb/ft3

8 Surface Tension5-80 dyne/cm

9 Liquid Viscosity 0.05-2.0 cP

10 Tray Spacing 14-36 in

11 Hole Diameter 1/8-1 in

12 Fractional Hole Area 0.06-0.20

13 Weir Height 0-3 in

Steps to calculate % Flooding using Kister and Haas correlation:

i. Calculate Weir Load (QL):

Liquid Load describes the flux of liquid across the tray.

Page 26: Tray

ii. Clear Liquid height at the transition from the froth to spray ((hct)

2. Jet Flood: Fair’s correlation

The Fair correlation has been standard of the industry for entrainment flood prediction. Fair’s correlation tends to be conservative, especially at high pressure and liquid rate.

This correlation possess following restriction:

Sr.No

Factors Applicability

1

Flooding Mechanism Entrainment (Jet) flood only

2

Tray Type Sieve Tray, Valve and Bubble-cap Tray

3

Hole size Hole£ ½ in (sieve tray)

Page 27: Tray

Weir height < 15% Tray Spacing

Steps to calculate % Flood using Fair’s correlation:

i. Calculate flow parameter

3. Down-comer choke-Koch correlation:

This is the more conservative correlation for checking Down-comer Design. Steps to calculate % Load Utilization using Kister and Haas correlation:

4. Hydraulic checks

Hydraulic check involves checking following parameters:

Page 28: Tray

- Flow Regime

- Entrainment

- Downcomer residence time

- Pressure Drop

- Downcomer backup

ii.Determination of Flow Regime

Froth Regime

This is the most commonly encountered flow regime in operating columns. The froth formed under this regime is described as one where the size and shape of bubbles is non-uniform and with rather large size distribution, as well as travelling at varying velocities. The liquid surface is either wavy or it presents oscillations. This is a liquid continuous flow regime.

Spray Regime

This regimes occurs at relatively high vapour velocities (i.e. large vapour flow rates) and low liquid loads, characteristics which are typical of vacuum systems. The vapour velocity is so large, that the liquid phase is completely disrupted and is no longer a continuous phase on top of the tray; liquid is a dispersed phase present only in the form of drops, and therefore the continuous phase is the vapour.

Emulsion Regime

Page 29: Tray

This flow regime is typically encountered in high-pressure systems and relatively high liquid loads. The shearing action of the high velocity liquid “tears off” the vapour bubbles leaving the orifices on the tray. Most of the gas is emulsified in small bubbles within the liquid, with the mixture behaving as a uniform two-phase fluid, obeying the Francis weir formula. This is a liquid continuous flow regime.

The determination of regime on tray given below is only for information and has no use in sizing.

ii. Froth-Emulsion Transition Check

This correlation is applicable for Sieve trays only.

The value of actual flow parameter is calculated as below:

If the value of actual flow parameter exceeds 0.0208 then the regime of operation is emulsion.

iii. Froth-Spray Transition Check:

Porter and Jenkins correlation for the froth to spray transition.

Page 30: Tray

Where,

Lw – weir length in inches, AB – Active area ft2

p – pitch in inches

hc – clear liquid height, inches

5. Entrainment:

If entrainment is excessive, column diameter or tray spacing are usually increased. As recommended value, the entrainment from the tray should not exceed about 0.10 lb liquid entrained per pound of liquid flow.

Methods to determine Entrainment:

Fair’s entrainment correlation

This method holds good for froth and emulsion regime. However it is less accurate for spray regime. For a trays operating at a high liquid to vapour ratio, 0.1 lb of liquid entrained per pound of liquid is an excessive quantity of entrained liquid.

Kister and Haas Correlation

Page 31: Tray

This method is used for Spray Regime; Es is entrainment lb of liquid / lb of vapour.


Recommended