+ All Categories
Home > Documents > U-Charge® XPmesa-tec.com/wp-content/uploads/2014/05/Mesa_Valence_U-Charge_BMS.pdfU-Charge® Battery...

U-Charge® XPmesa-tec.com/wp-content/uploads/2014/05/Mesa_Valence_U-Charge_BMS.pdfU-Charge® Battery...

Date post: 12-Oct-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
2
U-Charge® Battery Management Systems are designed to enable multiple system implementation options and advanced command and control ability. The BMS is compatible with U-Charge® XP battery modules. U-Charge® XP Battery Management System (BMS) Specifications Model Part No. U-BMS-LV 10V - 150V 1004443 U-BMS-HV 100V - 450V 1004440 U-BMS-SHV 350V - 700V 1004437 Dimensions (LxWxH) mm 188mm x 157mm x 42mm ** Dimensions (LxWxH) inches 7.4 x 6.18 x 1.65 ** Weight kg 0.55kg Weight Ibs 1.12Ibs External communication CAN 2.0b, 125, 250, 500 Kbit/s, standard frames Communications to battery modules RS-485 w/Valence protocol External control signals Control signal for line, pre-charge & charger contactors Monitoring parameters State-of-charge, error codes, system pack balance Isolation Chassis to battery insulation measurement Operating humidity 5% - 95%, non-condensing Mechanical enclosure IP56, UL 94V-0 (4x) 5 mm mounting holes Certifications FCC Class B, CE www.valence.com U-Charge® Battery Management Systems (BMS) are designed for use with U-Charge® XP battery modules. The BMS provides numerous system integration options facilitating temperature, voltage, current and state-of-charge monitoring. One single BMS is capable of managing up to 48 U-Charge® XP battery modules in 12V,18V or 36V configurations. U-Charge® Battery Modules offer twice the run-time at nearly half the weight of similar sized lead-acid batteries, offering outstanding intrinsic safety, excellent float and cycle life resulting in low cost of ownership. Thousands of U-Charge systems have been deployed since 2006, across numerous motive and energy storage applications. Monitoring, temperature, voltage, current, SOC status One U-BMS can manage multiple battery modules* CANbus communications for control and management Digital and analog I/O Battery-to-battery balance control Drive train pre-charge control Control of up to 4 contactors System ground isolation verification Sleep mode when key signal ‘OFF’ Overview Features ** incl. mounting tabs and protrusion of connectors
Transcript
Page 1: U-Charge® XPmesa-tec.com/wp-content/uploads/2014/05/Mesa_Valence_U-Charge_BMS.pdfU-Charge® Battery Management Systems are designed to enable multiple system implementation options

U-Charge® Battery Management Systems are designed to enable multiple system implementation options and advanced command and control ability. The BMS is compatible with U-Charge® XP battery modules.

U-Charge® XP Battery Management System (BMS)

SpecificationsModel Part No.

U-BMS-LV 10V - 150V 1004443

U-BMS-HV 100V - 450V 1004440

U-BMS-SHV 350V - 700V 1004437

Dimensions (LxWxH) mm 188mm x 157mm x 42mm **

Dimensions (LxWxH) inches 7.4 x 6.18 x 1.65 **

Weight kg 0.55kg

Weight Ibs 1.12Ibs

External communication CAN 2.0b, 125, 250, 500 Kbit/s, standard frames

Communications to battery modules RS-485 w/Valence protocol

External control signals Control signal for line, pre-charge & charger contactors

Monitoring parameters State-of-charge, error codes, system pack balance

Isolation Chassis to battery insulation measurement

Operating humidity 5% - 95%, non-condensing

Mechanical enclosure IP56, UL 94V-0 (4x) 5 mm mounting holes

Certifications FCC Class B, CE

www.valence.com

U-Charge® Battery Management Systems (BMS) are designed for use with U-Charge® XP battery modules.

The BMS provides numerous system integration options facilitating temperature, voltage, current and state-of-charge monitoring. One single BMS is capable of managing up to 48 U-Charge® XP battery modules in 12V,18V or 36V configurations.

U-Charge® Battery Modules offer twice the run-time at nearly half the weight of similar sized lead-acid batteries, offering outstanding intrinsic safety, excellent float and cycle life resulting in low cost of ownership. Thousands of U-Charge systems have been deployed since 2006, across numerous motive and energy storage applications.

Monitoring, temperature, voltage, current, SOC statusOne U-BMS can manage multiple battery modules*CANbus communications for control and management Digital and analog I/O Battery-to-battery balance controlDrive train pre-charge controlControl of up to 4 contactorsSystem ground isolation verificationSleep mode when key signal ‘OFF’

Overview Features

** incl. mounting tabs and protrusion of connectors

Page 2: U-Charge® XPmesa-tec.com/wp-content/uploads/2014/05/Mesa_Valence_U-Charge_BMS.pdfU-Charge® Battery Management Systems are designed to enable multiple system implementation options

Module Management Specifications

With Insulation Measurement

12 Volt U-Charge® XP 48

18 Volt U-Charge® XP 32

36 Volt U-Charge® XP 16

For further information:

Refer to U-Charge® Battery Modules datasheet

Without Insulation Measurement

1000 V DC series string limit or 70 module limit in series or parallel

Corporate HeadquartersNorth America Sales12303 Technology Blvd.Suite 950Austin, Texas 78727USA

Tel (888) VALENCE or +1 (512) 527-2900Fax +1 (512) 527-2910Email [email protected]

Performance may vary depending on, but not limited to cell usage and application. If cell is used outside specifications, performance will diminish. All specifications are subject to change without notice. All information provided herein is believed, but not guaranteed, to be current and accurate. Copyright © 2005-2012 Valence Technology, Inc.

Tell us about your application at: www.valence.com Aug 2012BMS Datasheet

EMEA SalesUnit 63 Mallusk Enterprise ParkMallusk Co.AntrimNorthern IrelandBT36 4GN

Tel +44(0) 28 9084 5400Fax +44(0) 28 9083 8912Email [email protected]

U-BMS-LV operates at 10V - 150V U-BMS-HV operates at 100V - 450VU-BMS-SHV operates at 350V - 700V


Recommended