+ All Categories
Home > Documents > UMTS Radio Parameter.ppt

UMTS Radio Parameter.ppt

Date post: 08-Nov-2015
Category:
Upload: william-m-arevalo
View: 24 times
Download: 6 times
Share this document with a friend
Popular Tags:
92
UMTS Radio Parameter ZTE University
Transcript
  • UMTS Radio ParameterZTE University

  • ContentUMTS Cell Selection and Reselection ParameterUMTS Intra-Frequency Handover ParameterUMTS Inter-Frequency Handover ParameterUMTS Inter-RAT Handover Parameter

  • Cell selection criteria-Rule SQqualmeasMeasured cell quality value. The quality of the received signal expressed in CPICH Ec/N0 (dB).QrxlevmeasMeasured cell RX level value. The quality of the received signal expressed in CPICH RSCP (dBm).QqualminMinimum required quality level in the cell (dB).QrxlevminMinimum required RX level in the cell (dBm).Pcompensationmax(UE_TXPWR_MAX_RACHP_MAX0)UE_TXPWR_MAX_RACHMaximum TX power level on RACH (dBm)P_MAXMaximum RF output power of the UE (dBm)Srxlev > 0 AND Squal > 0Squal Qqualmeas QqualminSrelev QrxlevmeasQrxlevminPcompensation

  • Camped Normally StateSelect and monitor the indicated PICH and PCH of the cell according to information sent in system information.Monitor relevant system information.Perform necessary measurements for the cell reselection evaluation procedure.Execute the cell reselection evaluation process.

  • Measurement rules for cell re-selectionIf Sx > SIntraSearch, UE does not measure intra-frequency cells.If Sx Sintersearch, UE does not measure inter-frequency cells.If Sx SSearchRat, UE does not measure inter-RAT cells.If Sx
  • Cell reselection criteria-Rule RQmeas,sQuality measurement result of serving cell.Qmeas,nQuality measurement result of neighbor cell.Qhyst1s Hysteresis value when measurement value is CPICH RSCP.Qhyst2s Hysteresis value when measurement value is CPICH Ec/No.Qoffset1s,n Offset of two cells when measurement value is CPICH RSCP.Qoffset2s,n Offset of two cells when measurement value is CPICH Ec/No.The new cell is better ranked than the serving cell during a time interval Treselection according to the R criteria.More than 1 second has elapsed since the UE camped on the current serving cell.Rs Qmeas,s + QhystsRn Qmeas,nQoffsets,n

  • Intra-Frequency Cell Re-Selection

  • Inter-RAT Cell Re-Selection

  • Quality measure for Cell Selection and Reselection

    Parameter NameQualMeasDescriptionThis parameter indicates the quality measure for cell selection and reselection.Range and Step1CPICH Ec/No2CPICH RSCPDefault Value1CPICH Ec/NoConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UltranCell->UltranCellXXX-> Cell Selection and Reselection -> Advanced Parameter Manager-> Measurement Quality for Cell Selection and Reselection

  • Minimum Required Quality Level in the Cell

    Parameter NameQQualMinDescriptionThis parameter indicates the minimum required quality level of the cell which satisfies the condition of being selected or reselected by UE. When the quality measure is CPICH Ec/No, only the measured quality of the cell is over Qqualmin can the cell be selected. Its -18dB by default.If value of the parameter is increased, its harder for the cell to satisfy the condition of being selected.If value of the parameter is decreased, its easier for the cell to satisfy the condition of being selected.Range and Step-240dB step 1dBDefault Value-18dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Minimum Required Quality Level in the Cell (Qqualmin)

  • Minimum Required Received Level in the Cell

    Parameter NameQRxLevMinDescriptionThis parameter indicates the minimum required received power level of the cell which satisfies the condition of being selected or reselected by UE. When the quality measure is CPICH RSCP, only the measured received power level of the cell is over Qrxlevmin can the cell be selected.If value of the parameter is increased, its harder for the cell to satisfy the condition of being selected.If value of the parameter is decreased, its easier for the cell to satisfy the condition of being selected.Range and Step-115-25dBm step 2dBmDefault Value-115dBmConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Minimum Required Received Level in the Cell (Qrxlevmin)

  • Maximum Allowed UL TX Power of RACH

    Parameter NameMaxRACHTxPwr DescriptionThis parameter indicates the maximum allowed UL transmission power of RACH.If value of configuration is increased, the maximum allowed UL transmission power of RACH increases.If value of configuration is decreased, the maximum allowed UL transmission power of RACH decreases.Range and Step-5033dBmDefault Value24dBmConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX-> Modify Advanced Parameter->PRACH-> Maximum Allowed UL TX Power of RACH(dBm)

  • Sintrasearch Configuration Tag

    Parameter NameSIntraSearchPreDescriptionThis parameter is a switch indicating whether Sintrasearch is configured or not. If the value is False, Sintrasearch is not configured to UE, and UE performs the intra-frequency measurement. If the value is True, Sintrasearch is configured to UE, and UE judges whether to perform the intra-frequency measurement. Range and Step0: Not configured to UE.1: Configured to UE.Default Value1: Configured to UE.Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> S-intrasearch Configuration Tag

  • Intra-Frequency Measurement Trigger Threshold for Cell Reselection

    Parameter NameSintrasearchDescriptionThis parameter indicates the intra-frequency measurement triggering threshold for cell reselection (Sintrasearch) used by UE to judge whether intra-frequency measurement should be performed. When HCS is not used, if the quality of serving cell exceeds Sintrasearch, UE may choose to not perform intra-frequency measurement. If the quality of serving cell is not larger than Sintrasearch or if Sintrasearch is not configured, UE performs intra-frequency measurement. Sintrasearch is delivered to the UE, if its value is increased, its easier for the UE to trigger intra-frequency measurement. If value of the parameter is decreased, its harder for the UE to trigger intra-frequency measurement.Range and Step020dB Step 2dBDefault Value14dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Intra-Frequency Measurement Trigger Threshold for Cell Reselection (Sintrasearch)

  • Sintersearch Configuration Tag

    Parameter NameSInterSearchPreDescriptionThis parameter is a switch which indicates whether Sintersearch is configured or not. If the value is False, Sintersearch is not configured to UE, and UE performs the inter-frequency measurement. If the value is True, Sintersearch is configured to UE, and UE judges whether to perform the inter-frequency measurement.Range and Step0: Not configured to UE.1: Configured to UE.Default Value1: Configured to UE.Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> S-intersearch Configuration Tag

  • Inter-Frequency Measurement Trigger Threshold for Cell Reselection

    Parameter NameSintersearchDescriptionThis parameter indicates the inter-frequency measurement triggering threshold for cell reselection (Sintersearch) used by UE to judge whether inter-frequency measurement should be performed. When HCS is not used, if the quality of serving cell exceeds Sintersearch, UE may choose to not perform inter-frequency measurement. If the quality of serving cell is not larger than Sintersearch or if Sintersearch is not configured, UE performs inter-frequency measurement. When Sintersearch is delivered to the UE, if its value is increased, its easier for the UE to trigger inter-frequency measurement. If value of the parameter is decreased, its harder for the UE to trigger inter-frequency measurement.Range and Step020dB Step 2dBDefault Value10dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Inter-Frequency Measurement Trigger Threshold for Cell Reselection (Sintersearch)

  • Inter-system Information Configuration Tag

    Parameter NameOtherRATInfoPreDescriptionThis parameter is a switch indicating whether inter-RAT information parameters used for cell reselection are configured or not. If the value is False, inter-RAT information parameters are not configured to UE, and UE performs the inter-RAT measurement. If the value is True, inter-RAT information parameters are configured to UE, and UE judges whether to perform the inter-RAT measurement.Range and Step0: Not configured to UE.1: Configured to UE.Default Value1: Configured to UE.Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Inter-system Information Configuration Tag

  • Inter-System Measurement Trigger Threshold for Cell Reselection

    Parameter NameSsearch,RATDescriptionThis parameter indicates the inter-RAT measurement triggering threshold for cell reselection (Ssearch,RAT) used by UE to judge whether inter-RAT measurement should be performed. When HCS is not used, if the quality of serving cell exceeds Ssearch,RAT, UE may choose to not perform inter-RAT measurement. If the quality of serving cell is not larger than Ssearch,RAT or if Ssearch,RAT is not configured, UE performs inter-RAT measurement. When Ssearch,RAT is delivered to the UE, if its value is increased, its easier for the UE to trigger inter-RAT measurement. If value of the parameter is decreased, its harder for the UE to trigger inter-RAT measurement.Range and Step020dB Step 2dBDefault Value6dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Inter-System Measurement Trigger Threshold for Cell Reselection (Ssearch,RAT)

  • Reselection Hysteresis 1 of Serving Cell

    Parameter NameQhyst1sDescriptionThis parameter indicates the hysteresis value for FDD cells in case the quality measure for cell selection and reselection is set to CPICH RSCP. In cell-ranking criterion R of cell reselection, the R value of serving cell equals to the measured value plus the hysteresis value. If value of the parameter is increased, its harder to trigger cell reselection as the R value of the serving cell will increase. If value of the parameter is decreased, its easier to trigger cell reselection as the R value of the serving cell will decrease.Range and Step040dB step 2dBDefault Value10dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Reselection Hysteresis 1 of Serving Cell (Qhyst1s)

  • Reselection Hysteresis 2 of Serving Cell

    Parameter NameQhyst2sDescriptionThis parameter indicates the hysteresis value for FDD cells in case the quality measure for cell selection and reselection is set to CPICH Ec/No. In cell-ranking criterion R of cell reselection, the R value of serving cell equals to the measured value plus Qhyst2s. If value of the parameter is increased, its harder to trigger cell reselection as the R value of the serving cell will increase. If value of the parameter is decreased, its easier to trigger cell reselection as the R value of the serving cell will decrease.Range and Step040dB step 2dBDefault Value2dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UtranCell->UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX-> Modify Advanced Parameter-> Qhyst2s (dB)

  • Quality Offset 1 Between Serving Cell and Neighbouring Cell

    Parameter NameQoffset1s,nDescriptionThis parameter indicates the quality offset of the serving cell and neighbor cell when the quality measure is CPICH RSCP. This parameter is required when queues cells in the cell reselection rule. This parameter is broadcast to UE in SIB11. R of neighbor cell = measured signal quality of neighbor cell - this offset. If value of the parameter is increased, its harder to trigger cell reselection as the R value of the neighbor cell will decrease. If value of the parameter is decreased, its easier to trigger cell reselection as the R value of neighbor cell will probably increase.Range and StepOMCR-5050dBRNCD=P+500100Default Value0dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UltranCell->UltranCellXXX->Neighbouring Cell -> Advanced Parameter Manager-> Quality Offset 1(Qoffset1s,n ) Between Serving Cell and Neighbouring Cell Broadcasted in SIB11

  • Quality Offset 2 Between Serving Cell and Neighbouring Cell

    Parameter NameQoffset2s,nDescriptionThis parameter indicates the quality offset of the serving cell and neighbor cell when the quality measure is CPICH Ec/No. This parameter is required when queues cells in the cell reselection rule. This parameter is broadcast to UE in SIB11. R of neighbor cell = measured signal quality of neighbor cell - this offset. If value of the parameter is increased, its harder to trigger cell reselection as the R value of the neighbor cell will decrease. If value of the parameter is decreased, its easier to trigger cell reselection as the R value of neighbor cell will increase.Range and StepOMCR-5050dBRNCD=P+500100Default Value0dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UltranCell->UltranCellXXX-> Neighbouring Cell -> Advanced Parameter Manager-> Quality Offset 2(Qoffset2s,n ) Between Serving Cell and Neighbouring Cell Broadcasted in SIB11

  • Cell Reselection Timer Value

    Parameter NameTreselectionsDescriptionThis parameter indicates the cell reselection timer value. UE will reselect the new cell if the new cell is best ranked according to the criterion R during a time interval indicated by Treselection and the new cell can be selected as new serving cell only after extension of the reselection timer. If value of the parameter is increased, its harder to trigger cell reselection. If value of the parameter is decreased, its easier to trigger cell reselection.Range and Step031s step 1sDefault Value1sConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UltranCell-> UtranCellXX->Cell Selection and Reselection-> Cell Selection and ReselectionX->Advanced Parameter Manager -> Cell Reselection Timer Value (Treselections)

  • Cell Barred Indicator

    Parameter NameCellBarredIndDescriptionThis parameter is cell barred indicator. If the cell barred indicator is set to Barred, UEs are not permitted to select/re-select this cell, even for emergency calls.Range and Step1: Barred2: Not BarredDefault Value2: Not BarredConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UltranCell->UltranCellXXX->Cell Selection and Reselection -> Cell Selection and ReselectionX-> Advanced Parameter Manager-> Cell Barred Indicator

  • Measurement Priority of Neighboring Cell

    Parameter NameMeasPrioDescriptionThis parameter indicates the measurement priority of the neighboring cell. The highest priority is 0, the lowest priority is 2.Range and Step02Default Value0Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->UTRAN Cell -> UTRAN Cell xxx ->Neighbouring Cell -> Measurement Priority of Neighboring Cell

  • ContentUMTS Cell Selection and Reselection ParameterUMTS Intra-Frequency Handover ParameterUMTS Inter-Frequency Handover ParameterUMTS Inter-RAT Handover Parameter

  • Intra-Frequency Handover The intra-frequency handover can be triggered based on Ec/No or RSCP measurement through the parameter IntraMeasQuan.Active setMonitored setDetected set

  • Cell PriorityThe OMCR configuration parameter MeasPrio is used to define the priority of adjacent cells and includes three values:0: High priority1: Medium priority2: Low priority

    1

  • Intra-frequency measurement eventsA series of intra-frequency measurement events are defined in 3GPP as the judgment and trigger criteria for intra-frequency handover.Event 1A: A Primary CPICH enters the Reporting Range. Event 1B: A Primary CPICH leaves the Reporting Range. Event 1C: A Non-active Primary CPICH becomes better than an active Primary CPICH. Event 1D: The best cell changes.

  • Event 1AR1a: Refers to the reporting range of Event 1A. It is used to control the extent of difficulty in adding a cell into the active set.H1a: Refers to the reporting hysteresis of Event 1A. It is used to control the extent of difficulty in adding a cell into the active set.Mnew: Refers to measurement of the to-be-evaluated cell outside the active set.CIOnew: Refers to offset of cell outside active set in relation to other.Mi: Refers to the mean measurement value of other cells except the best cell in active set.NA: Refers to the number of other cells except the best cell in active set.Mbest: Refers to the measurement of the best cell in the active set.W: Refers to the weight proportion of the best cell to the rest cells in the active set in evaluation standards.

  • Event 1A

  • Event 1BR1b: Refers to the reporting range of Event 1B. It is used to control the extent of difficulty in dropping a cell from the active.H1b: Refers to the reporting hysteresis of Event 1B. It is used to control the extent of difficulty in dropping a cell from the active set.Mold: Refers to measurement of the to-be-evaluated cell in the active set.CIOold: Refers to offset of cell in active set in relation to other cells.Mi: Refers to the mean measurement value of other cells except the best cell in active set.NA: Refers to the number of other cells except the best cell in active set.Mbest: Refers to the measurement of the best cell in the active set.W: Refers to the weight proportion of the best cell to the rest cells in the active set in evaluation standards.

  • Event 1B

  • Event 1C

    H1c: Refers to the reporting hysteresis of Event 1C. It is used to control the extent of difficulty in replacing a cell in the active set.Mnew: Refers to measurement of the to-be-evaluated cell outside the active set.MInAS: Refers to the cell with poorest quality in the active set.CIOnew: Refers to offset of the to-be-evaluated cell outside the active set in relation to other cells.CIOInAS: Refers to offset of cell with poorest quality in active set in relation to other cells.

  • Event 1C

  • Event 1D

    MNotbest: Refers to the measurement of the to-be-evaluated cell within or outside the active set.CIONotbest: Refers to the offset of the to-be-evaluated cell within the active set or outside the active set in relation to other cells.CIObest: Refers to offset of the to-be-evaluated cell in the active set in relation to other cells.Mbest: Refers to the measurement of the to-be-evaluated cell in the active set.H1d: Refers to Event 1D report hysteresis.

  • Event 1D

  • Cell Individual OffsetFor each cell that is monitored, an offset can be assigned with inband signalling. The offset can be either positive or negative. The offset is added to the measurement quantity before the MS dose evaluate while an event has occurred. Offset of neighbor cell parameter, CPICH Ec/No, can be set as the offset which MS pluses it to neighbor cell measurement result, CPICH Ec/No, before compares it with reporting principle value, Ec/No.Cell individual offsets can be regarded as the tool of moving cell edge.

  • Time-To-TriggerIf a to-be-evaluated cell meets the reporting range or threshold of certain event, the condition must be met within a period of time before the reporting of this event to avoid intra-frequency event misreport due to the fluctuation of radio quality.

    TrigTime[MAX_INTRA_MEAS_EVENT]

    RptRange [MAX_INTRA_MEAS_EVENT]

    Time

    Measurementquantity

    Reporting event 1A

    P CPICH 3

    P CPICH 1

    P CPICH 2

  • Intra-Frequency Handover

  • Measurement Priority of Neighboring Cell

    Parameter NameMeasPrioDescriptionThis parameter indicates the measurement priority of the neighbouring cell. The priority of the neighbouring cell can be set to 0, 1, or 2, of which, 0 represents the highest priority and 2 represents the lowest priority. The priority of the neighbouring is set by the configuration personnel according to the signal strength and distance of the neighboring cell.Range and Step02Default Value0Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->Neighbouring Cell-> Neighbouring Cell XXX-> Measurement Priority of Neighboring Cell

  • Report Criteria

    Parameter NameRptCrtDescriptionThis parameter indicates the reporting criteria of the intra-frequency measurement, including the event reporting criteria and the periodical reporting criteria.Range and Step1: Event Reporting Criteria2: Periodical Reporting CriteriaDefault ValueUE Event Report Parameters for CPICH Ec/No: Event Reporting CriteriaUE Event Report Parameters for CPICH RSCP: Event Reporting CriteriaConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Intra-frquence Measurement Configuration-> Report Criteria

  • Measurement Quantity

    Parameter NameMeasQuantityDescriptionThis parameter indicates the measurement quantity of the intra-frequency measurement that UE performs. Range and Step0CPICH Ec/No1CPICH RSCP2PathlossDefault ValueUE Event Report Parameters for CPICH Ec/No: CPICH Ec/NoUE Event Report Parameters for CPICH RSCP: CPICH RSCPConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Intra-frquence Measurement Configuration-> Measurement Quantity

  • Reporting Range Constant Event 1A/1B

    Parameter NameRptRangeDescriptionEvent 1A is easier to be triggered when the reporting range constant for event 1A is set to a larger value; and vice verse.Event 1B is easier to be triggered when the reporting range constant for event 1B is set to a smaller value; and vice verse.Range and Step014.5dBstep 0.5dBDefault ValueUE Event Report Parameters for CPICH Ec/No: [3,5,0,0,0,0,0]UE Event Report Parameters for CPICH RSCP: [6,8,0,0,0,0,0]Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Intra-frquence Measurement Configuration->Reporting Range Constant Event 1A/1B(dB)

  • Hysteresis

    Parameter NameHysteresisDescriptionThis parameter indicates the hysteresis when judging whether to trigger the event. This parameter avoids the change of the trigger status due to very small change. This parameter is related to the measurement quantity and the event type.Range and Step07.5dBstep 0.5dBDefault ValueUE Event Report Parameters for CPICH Ec/No: [0,0,4,4,2,2,4]UE Event Report Parameters for CPICH RSCP: [4,4,6,6,4,4,6]Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Intra-frquence Measurement Configuration-> Hysteresis

  • Weight for Event 1A/1B

    Parameter NameWDescriptionThis parameter is used for the quality judgment of event 1A and 1B. This parameter indicates the weight of the best cell in the quality judgment and is related to the measurement quantity and the event type.Range and Step0.02.0step 0.1Default ValueUE Event Report Parameters for CPICH Ec/No: [0.0 0.0 0.0 0.0 0.0 0.0 0.0]UE Event Report Parameters for CPICH RSCP: [0.0 0.0 0.0 0.0 0.0 0.0 0.0]Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Intra-frquence Measurement Configuration-> Weight for Event 1A/1B

  • Time to Trigger

    Parameter NameTrigTimeDescriptionThis parameter indicates the time difference between the time that the event generation is detected and the time that the event is reported. The event is triggered and the measurement report is reported only when the event generation is detected and still meets the requirements of event triggering after Time to trigger.Range and Step0 10 20 40 60 80 100 120 160200 240 320 640 1280 2560 5000msDefault ValueUE Event Report Parameters for CPICH Ec/No: [200,640,320,320,200,200,320]msUE Event Report Parameters for CPICH RSCP: [200,200,200,200,200,200,200]msConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Intra-frquence Measurement Configuration-> Time to Trigger(ms)

  • ContentUMTS Cell Selection and Reselection ParameterUMTS Intra-Frequency Handover ParameterUMTS Inter-Frequency Handover ParameterUMTS Inter-RAT Handover Parameter

  • Carrier evaluation standard

    Qfrequency j: Refers to active set quality of carrier j, that is, the measurement result of carrier j.Mfrequency j: Refers to the physical measurement value of the active set of carrier j.Mi j: Refers to the physical measurement value of cell i of carrier j.NA j: Refers to the number of cells (excluding best cell) in the active set of carrier j.MBest j: Refers to the measurement result of the best cell in the active set of carrier j.Wj: Refers to the weight of the best cell in the active set of carrier j during carrier measurement.

  • Inter-frequency measurement eventsA series of inter-frequency measurement events are defined in 3GPP as the judgment and trigger criteria for inter-frequency handover:Event 2A: The best carrier frequency changes. Event 2B: The quality of working carrier frequency is lower than a threshold and that of non-working carrier frequency is higher than a threshold. Event 2C: The quality of non-working carrier frequency is higher than a threshold. Event 2D: The quality of working carrier frequency is lower than a threshold. Event 2E: The quality of non-working carrier frequency is lower than a threshold.Event 2F: The quality of working carrier frequency is higher than a threshold.

  • Event 2A

    QNotBest: Refers to the measurement result of current non-best carrier frequency.QBest: Refers to the measurement result of current best carrier frequency.H2a: Refers to handover decision hysteresis parameter of Event 2A.

  • Event 2A

  • Event 2B

    QNon used: Refers to the measurement result of current non-working carrier frequency.TNon used 2b: Refers to the absolute threshold of good quality of non-working carrier frequency in Event 2B decision.H2b: Refers to handover decision hysteresis parameter of Event 2B.QUsed: Refers to the measurement result of current working carrier frequency.TUsed 2b: Refers to the absolute threshold of poor quality of working carrier frequency in Event 2B decision.and

  • Event 2B

  • Event 2C

    QNon used: Refers to the measurement result of current non-working carrier frequency.TNon used 2c: Refers to the absolute threshold of good quality of non-working carrier frequency in Event 2C decision.H2c: Refers to handover decision hysteresis parameter of Event 2C.

  • Event 2C

  • Event 2D

    QUsed: Refers to the measurement result of current working carrier frequency.TUsed 2d: Refers to the absolute threshold of poor quality of working carrier frequency in Event 2D decision.H2d: Refers to handover decision hysteresis parameter of Event 2D.

  • Event 2E

    QNon used: Refers to the measurement result of current non-working carrier frequency.TNon used 2e: Refers to the absolute threshold of good quality of non-working carrier frequency in Event 2E decision.H2e: Refers to handover decision hysteresis parameter.

  • Event 2F

    QUsed: Refers to the measurement result of current working carrier frequency.TUsed 2f: Refers to the absolute threshold of poor quality of working carrier frequency in Event 2F decision.H2f: Refers to handover decision hysteresis parameter of Event 2F.

  • Event of inter-frequency handoverThe same cell can only use one of Event 2A, Event 2B and Event 2C to trigger inter-frequency handover. Which of the three events will be used is based on the inter-frequency handover recommendation strategy parameter InterHoTactic.

  • Handling of Event 2EAll non-working carrier frequencies report Event 2E, indicating that radio quality of all inter-frequency adjacent cells is poor and UMTS system quality deteriorates. Issue the Inter-RAT measurement Event 3A/3C.

  • Inter-Frequency Handover

  • Inter-Frequency HandoverEc_f1Ec_f22Dt2F2D2F2A2DRSCP

  • Measurement Priority of Neighboring Cell (Inter)

    Parameter NameMeasPrio(Inter)DescriptionThe priority of a neighbouring cell can be set to 0, 1, and 2, of which, 0 represents the highest priority and 2 represents the lowest priority. The priority of the neighbouring is set by the configuration personnel according to the signal strength and the distance of the neighboring cell.Range and Step02Default Value0Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->Neighbouring Cell-> Neighbouring Cell XXX->Measurement Priority of Neighboring Cell

  • Report Criteria (Inter)

    Parameter NameRptCrt(Inter)DescriptionThis parameter indicates the criteria of reporting the inter-frequency measurement, including the Event Reporting and periodical reporting.Range and Step1: Inter-frequency Event Reporting Criteria2: Periodical Reporting CriteriaDefault ValueUE Inter-frequency Event Report Parameters for CPICH Ec/No: Inter-frequency Event Reporting CriteriaUE Inter-frequency Event Report Parameters for CPICH RSCP: Inter-frequency Event Reporting CriteriaConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-frquence Measurement Configuration-> Report Criteria

  • Measurement Quantity (Inter)

    Parameter NameMeasQuantity(Inter)DescriptionThis parameter indicates the measurement quantity of the inter-frequency measurement that UE performs. Range and Step0 CPICH Ec/No1 CPICH RSCPDefault ValueUE Inter-frequency Event Report Parameters for CPICH Ec/No: CPICH Ec/NoUE Inter-frequency Event Report Parameters for CPICH RSCP: CPICH RSCPConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-frquence Measurement Configuration-> Measurement Quantity

  • Weight of the Currently Used Frequency for 2A/2B/2D/2F

    Parameter NameWusedDescriptionThis parameter is used for quality judgment of the currently used carrier frequency. It indicates the weight of the best RNC in the quality judgment (only for event 2a/2b/2d/2f) and is related to the measurement quantity and the event type.Range and Step0.02.0step 0.1Default ValueUE Inter-frequency Event Report Parameters for CPICH Ec/No: [0.0, 0.0, 0.0,0.0,0.0,0.0]UE Inter-frequency Event Report Parameters for CPICH RSCP: [0.0, 0.0, 0.0,0.0,0.0,0.0]Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Modify Advanced Parameter->UE Inter-frequence Measurement Configuration-> Weight of the Currently Used Frequency for 2A/2B/2D/2F

  • Absolute Threshold of the Quality of the Currently Used Frequency for 2B/2D/2F

    Parameter NameThreshUsedFreqDescriptionThis parameter indicates the absolute threshold that should be configured for event 2b/2d/2f.In the case of event 2D, the less the threshold configured, the more difficult the event 2D been triggered. In the case of event 2F, the less the threshold configured, the easier the event 2F been triggered.Range and StepCPICH RSCP-115-25dBm step 1dBmCPICH Ec/No-240dB step 1dBDefault ValueUE Inter-frequency Event Report Parameters for CPICH Ec/No: [-24,-13, -24,-13,-24,-8]dBUE Inter-frequency Event Report Parameters for CPICH RSCP: [-115,-95, -115,-95,-115,-80]dBmConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Modify Advanced Parameter->UE Inter-frequence Measurement Configuration-> Absolute Threshold of the Quality of the Currently Used Frequency for 2B/2D/2F

  • Hysteresis (Inter)

    Parameter NameHysteresis(Inter)DescriptionThis parameter indicates the hysteresis used when judging whether to trigger the event. This parameter avoids the trigger status change due to very small change. Different events are configured separately and the events can be configured with different values. Range and Step014.5dB step 0.5dBDefault ValueUE Inter-frequency Event Report Parameters for CPICH Ec/No: [4,4,4,4,4,4]dBUE Inter-frequency Event Report Parameters for CPICH RSCP: [4,4,4,4,4,4]dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Modify Advanced Parameter->UE Inter-frequence Measurement Configuration-> Hysteresis(dB)

  • Time to Trigger (Inter)

    Parameter NameTrigTime(Inter)DescriptionThis parameter indicates the time difference between the time that the event generation is detected and the time that the event is reported. The event is triggered and the measurement report is reported only when the event generation is detected and still meets the requirements of event triggering after Time to trigger. Range and Step0 10 20 40 60 80 100 120 160 200 240 320 640 1280 2560 5000msDefault ValueUE Inter-frequency Event Report Parameters for CPICH Ec/No: [100,100,100,640,100,640]UE Inter-frequency Event Report Parameters for CPICH RSCP: [100,100,100,640,100,640]Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Modify Advanced Parameter->UE Inter-frequency Measurement Configuration-> Time to Trigger(ms)

  • Inter- frequency Handover Tactic

    Parameter NameInterHoTacticDescriptionThis parameter indicates the event that is used to trigger the inter-frequency handover. The default value of the parameter is 2A, that is, the handover can be triggered when the conditions for best carrier frequency change are satisfied.Range and Step0: Algorithm Deciding1: 2A Event Trigger2: 2B Event Trigger3: 2C Event TriggerDefault Value1: 2A Event TriggerConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->Modify Advanced Parameter->Utran Cell-> Inter- frequency Handover Tactic

  • Share Cover Indication

    Parameter NameShareCoverDescriptionThis parameter describes the neighboring relationship of the current cell and the neighboring cell. The relationship between the neighbouring cell and the current cell may be Neighbor, Overlap, Covers, or Contained in.Range and Step0: Neighbor1: Overlap2: Covers3: Contained inDefault Value0: NeighborConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->Neighbouring Cell->Neighbouring Cell XXX -> Share Cover Indication

  • Inter Frequency or Inter RAT Handover Switch

    Parameter NameIfOrRatHoSwchDescriptionThis parameter indicates how to perform neighbor measurement if a cell has both inter-frequency and inter-RAT cells as its neighbors.Range and Step0: Turn off Inter-frequency and Inter-RAT Handover1: Only Inter Frequency2: Only Inter Rat3: Inter Frequency is Prior to Inter RatDefault Value3: Inter Frequency is Prior to Inter RatConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->Modify Advanced Parameter->Utran Cell->Inter Frequency or Inter RAT Handover Switch

  • ContentUMTS Cell Selection and Reselection ParameterUMTS Intra-Frequency Handover ParameterUMTS Inter-Frequency Handover ParameterUMTS Inter-RAT Handover Parameter

  • Inter-RAT measurement events3GPP defies a series of Inter-RAT measurement events. An UE reports the corresponding events when defined conditions are met.3A: The currently used UTRAN carrier quality is lower than a threshold, and the quality of other radio systems is higher than a threshold. It is used for decision of Inter-RAT handover.3C: The quality of other radio systems is higher than a threshold. It can be used for Inter-RAT handover decision.

  • Event 3A

    Qused: indicates the estimated quality of the used frequency of the UTRAN.Tused: indicates the absolute threshold of the currently used frequency difference.H3a: is the hysteresis parameter for 3A event decision.MOther RAT: is the quality measurement result of other systems.CIOOther RAT: is the quality offset of other system cells.TOther RAT: is the absolute threshold of other systems.and

  • Event 3C

    MOther RAT: is the quality measurement result of other systems.CIOOther RAT: is the quality offset of other system cells.TOther RAT: is the absolute threshold of other systems.H3c: is the hysteresis parameter for 3C event decision.

  • Inter-RAT HandoverThe RNC transmits the 2D ad 2F event configuration to the UE when the service is set up. If the UE reports a 2D event, that is, the current carrier is in poor signal quality, the UE reports a 2E event after inter-frequency measurement is started (that is, the signal quality of the measured inter-frequency neighboring cell is also poor), the RNC needs to configure and start Inter-RAT measurement 3A or 3C event to the UE, and then performs the corresponding decision process for Inter-RAT handover according to the 3A, or 3C event subsequently reported by the UE.

  • Inter-RAT Handover

  • Inter-RAT HandoverEc_f1GSM2Dt2F2D2F3A2D3A(G)RSCP3A(W)

  • Inter-frequency + Inter-RAT HandoverEc_f1GSMEc_f22Dt2F2D2F2E3A2D2E3A(G)3A(W)RSCP

  • Measurement Priority of Neighboring GSM Cell

    Parameter NameMeasPrio(Rat)DescriptionThis parameter indicates the measurement priority of the neighboring cell. 0 presents the highest priority and 2 presents the lowest priority. This parameter should be configured by the network planning engineer according to the actual conditions of the current network, including the quality and geographic position of the inter-RAT neighbouring cell.Range and Step02Default Value0Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->GSM Neighbouring Cell->GSM Neighbouring Cell XXX-> Measurement Priority of Neighboring GSMCell

  • Report Criteria

    Parameter NameRptCrt(Rat)DescriptionThis parameter indicates the criteria of reporting the inter-RAT measurement, including the Event Reporting and Periodical Reporting.Range and Step1: Inter-RAT Event Reporting Criteria2: Periodical Reporting CriteriaDefault ValueUE Event Report Parameters for Own System CPICH Ec/No: Inter-RAT Event Reporting CriteriaUE Event Report Parameters for Own System CPICH RSCP: Inter-RAT Event Reporting CriteriaConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-Rat Measurement Configuration Information-> Report Criteria

  • UTRAN Measurement quantity

    Parameter NameOwnMeasQuantityDescriptionThis parameter indicates the measurement quantity of the inter-RAT measurement that UE performs. After a new inter-RAT measurement configuration index is added, the measurement quantity is fixed when the function of the set of the inter-RAT measurement parameters is selected.Range and Step0: CPICH Ec/No1: CPICH RSCPDefault ValueUE Event Report Parameters for Own System CPICH Ec/No: CPICH Ec/NoUE Event Report Parameters for Own System CPICH RSCP: CPICH RSCPConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-Rat Measurement Configuration Information->UTRAN Measurement quantity

  • Weight of the UTRAN System for 3A

    Parameter NameW(Rat)DescriptionThis parameter indicates the weight of the best cell in the quality judgment of event 3a. It is used in judging the quality of the UTRAN system in inter-RAT measurement.Range and Step[0.0, 2.0], step 0.1Default ValueUE Event Report Parameters for Own System CPICH Ec/No: [0, -, -, -]UE Event Report Parameters for Own System CPICH RSCP: [0, -, -, -]Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-RAT Measurement Configuration Information->Weight of the UTRAN System for 3A

  • Absolute Threshold of the Quality of UTRAN Cell for 3A

    Parameter NameThresh(Rat)DescriptionThis parameter indicates the absolute threshold of the UTRAN cell quality that is used by UE to judge event 3a. The range and unit of the parameter are related to the measurement quantity of the cells of the UTRAN system. The smaller the value configured, the more difficult the event 3a been reported.Range and StepCPICH RSCP: [-115, -25] dBm, step 1dBmCPICH Ec/No: [-24, 0] dB, step 1dBDefault ValueUE Event Report Parameters for Own System CPICH Ec/No: [-6, -24,-24,-24]UE Event Report Parameters for Own System CPICH RSCP: [-95, -115,-115,-115]Configuration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-RAT Measurement Configuration Information->Absolute Threshold of the Quality of UTRAN Cell for 3A

  • Absolute Threshold of the Quality of Other RAT for 3A/3B/3C

    Parameter NameThreshSysDescriptionThis parameter indicates the absolute threshold used when judging the quality of other RAT configured for event 3a/3b/3c. The value range and unit of this parameter are related to the measurement quantity of the cells of other systems. At present, the measurement quantity can only be GSM Carrier RSSI of the GSM system, which corresponds to the CPICH RSCP of the UMTS system. Range and StepCPICH RSCP -115-25dBm step 1dBmCPICH Ec/No -240 dB step 1dBDefault ValueUE Event Report Parameters for Own System CPICH Ec/No: [-90, -95, -95, -115] dBmUE Event Report Parameters for Own System CPICH RSCP: [-90, -95, -95, -115] dBmConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-RAT Measurement Configuration Information-> Absolute Threshold of the Quality of Other RAT for 3A/3B/3C

  • Hysteresis(Rat)

    Parameter NameHysteresis(Rat)DescriptionThis parameter indicates the hysteresis used when judging whether the event meets the conditions of been triggered. This parameter is related to the measurement quantity and the event type. If a small hysteresis is configured, the corresponding event will be reported in a high probability; and vice versa.Range and Step[0., 7.5] dB, step 0.5 dBDefault ValueUE Event Report Parameters for Own System CPICH Ec/No: [4,4,2,4] dBUE Event Report Parameters for Own System CPICH RSCP: [4,4,4,4] dBConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-RAT Measurement Configuration Information-> Hysteresis

  • Time to Trigger(Rat)

    Parameter NameTrigTime(Rat)DescriptionThis parameter indicates the time difference between the time that the event generation is detected and the time that the event is reported. The event can be triggered and reported only when the event is detected and still meets all requirements of event triggering after Time to trigger. The larger the value is, the stricter the judgment is for the event to be triggered. Range and Step(0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000) msDefault ValueUE Event Report Parameters for Own System CPICH Ec/No: [100,100,100,100] msUE Event Report Parameters for Own System CPICH RSCP: [100,100,100,100] msConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management-> Modify Advanced Parameter->UE Inter-RAT Measurement Configuration Information-> Time to Trigger

  • Inter-Rat Handover Tactic

    Parameter NameRatHoTacticDescriptionEvent 3C can be triggered when the quality of the inter-RAT carrier frequency signal is higher than a certain value. In contrast, the trigger of event 3A requires an additional condition, that is, the quality of the carrier frequency signal of the current RAT must be less than a certain value. Hence, the inter-RAT handover can be triggered more easily when the parameter is set to 3C Event Trigger.Range and Step0: Algorithm Deciding1: 3A Event Trigger2: 3C Event TriggerDefault Value1: 3A Event TriggerConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->Modify Advanced Parameter->Utran Cell->Inter-RAT Handover Tactic

  • Share Cover Indication

    Parameter NameGsmShareCoverDescriptionThis parameter indicates the neighboring relationship of the current cell and GSM neighboring cell, including Neighbor, Overlap, Covers, and Contained in.Range and Step0: Neighbor1: Overlap2: Covers3: Contained inDefault Value0: NeighborConfiguration PathView->Configuration Management->RNC NE->RNC Radio Resource Management->Utran Cell->Utran Cell XXX->GSM Neighbouring Cell-> GSM Neighbouring Cell XXX ->Share Cover Indication

  • **


Recommended