Short circuit and overload protection Automatically charging battery at UPS omode Fan speed auto control when load varies Standard RS232 communication port Monitoring system USB/SNMP (optional) Emergency power o(EPO) External battery bank port Isolation transformer Manual bypass on 6 ~ 10 KVA Optional N+X redundancy parallel on 6 ~ 10KVA (to up 6 units in parallel) High frequency and true double-conversion DSP digital control technology Input power factor correction (PFC) Wide input voltage range (110V ~ 300V) Output power factor 0.9 Cold start (Turn on DC) Frequency auto-adaptive ECO mode operation for energy saving Selectable output voltage via LCD Selectable battery low voltage via LCD Automatically diagnose when starts Advanced battery management (ABM) CHARACTERISTICS UPS 6 & 10 KVA Rear Panel www. kenjitsuUSA. com Aplications To protect critical equipment telecommunications, computers, PLC, medical equipment, security systems, etc. AC Input terminals External battery bank port Breaker Outlet terminals Fan RS232 port 1 2 3 4 5 6 USB port EPO switch SNMP/AS400 port Manual bypass 7 8 9 10 6KVA & 10KVA 8 5 3 1 4 5 2 10 6 7 9 for High Availability Systems Uninterruptible power supply
Transcript

Short circuit and overload protection

Automatically charging battery at UPS off mode

Fan speed auto control when load varies

Standard RS232 communication port

Monitoring system USB/SNMP (optional)

Emergency power off (EPO)

External battery bank port

Isolation transformer

Manual bypass on 6 ~ 10 KVA

Optional N+X redundancy parallel on 6 ~ 10KVA

(to up 6 units in parallel)

High frequency and true double-conversion

DSP digital control technology

Input power factor correction (PFC)

Wide input voltage range (110V ~ 300V)

Output power factor 0.9

Cold start (Turn on DC)

Frequency auto-adaptive

ECO mode operation for energy saving

Selectable output voltage via LCD

Selectable battery low voltage via LCD

Automatically diagnose when starts

Advanced battery management (ABM)

CH

AR

AC

TER

ISTI

CS

UPS 6 & 10 KVA Rear Panel

www.kenjitsuUSA.com

AplicationsTo protect critical equipment telecommunications,

computers, PLC, medical equipment, security systems, etc.

AC Input terminals

External battery bank port

Breaker

Outlet terminals

Fan

RS232 port

1

2

3

4

5

6

USB port

EPO switch

SNMP/AS400 port

Manual bypass

7

8

9

10

6KVA & 10KVA

8

5

3

1 4

52

10

6 7

9

for High Availability Systems

Uninterruptible power supply

MODELCapacityINPUTInput voltageVoltage rangeFrequencyInput current (Max.)Power FactorTotal Harmonic Distortion (THDI)Bypass voltage rangeOUTPUT

Power Factor

Voltage accuracy Load crestTransfer time from AC mode to BAT modeTransfer time from BAT mode to AC modeEFFICIENCY Line mode BAT mode ECO modeBATTERY Battery type Quantity x CapacityDC voltage Backup timeCharger currentBattery bank external connector SYSTEM CONTROL & COMMUNICATION Communication port

ENVIRONMENT Operating temperatureRecommended temperatureStorage temperatureCoolingHumidityNoise levelPHYSICAL Dimension WxDxHWeight with internal batteries

KENJITSU UPS, POWER SAN SERIESPS6K

6KVA / 5400W

16 x (12/9AH)192V

18min 6s (50% load)

RS232; USB, SNMP card (optional)

Normal up to 1000m, 1% derating in every 100mLast generation IGBT, inverter & rectifier

1A / 3A / 5A / 8A (selectable)

0°C ~ 40°C15°C ~ 25°C15°C ~ 50°C

Fan speed auto control when load varies20 ~ 90% (non condensing)

≤55dB

115.2Kg 116.2Kg(262 x 690 x 735)

Graphics analyze; Switch on/off UPS system; Monitor UPS working status; History record and event log

Over-temp protection; Fan testing protection; Output short circuit protection

09min 0s (50% load)192V

16 x (12/9AH)

24A 45A

220V (L1 - L2, G)

≥0.98<5%

(180 - 255) ±5Vac 100% load

(115 - 295) ±5Vac (60% load); (155 - 295) ±5Vac (100% load) (50/60) Hz auto-adaptive ; (40 - 70Hz, ±0.5%)

(208/220/230/240) Vac Setting available via LCD(115/120/127)Vac Setting available via LCD

0.9

±1%3:1

0ms0ms

≥92% (Full! load & 100% charged batteries)≥91% (Full! load & 100% charged batteries)

≥98% (Full! load & 100% charged batteries)

Sealed lead add maintenance free battery (VLRA)

Full linear load <2%Full! Non-linear load <5%

105% - 125%: 3min; 125% - 150%: 30sec; >150%: 100ms;

10KVA / 9000WPS10K

Total Harmonic Distortion (THDv)

Inverter overload capability

TopologyAltitude

Software function

Protection

Voltage range

Anderson gray connector type (cover for connector)

AUTHORIZED DEALER:

www.kenjitsulatam.com


Recommended