+ All Categories
Home > Documents > US Department of Energy DOE: Sustainability Plan 2010

US Department of Energy DOE: Sustainability Plan 2010

Date post: 07-Apr-2018
Category:
Upload: linda-louise
View: 220 times
Download: 0 times
Share this document with a friend

of 92

Transcript
  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    1/92

    Strategic

    SustainabilityPerformancePlanReportto:TheCouncilonEnvironmentalQualityTheOfficeofManagementandBudgetJune2,2010

    U.S.DepartmentofENERGY

    UnitedStatesDepartmentofEnergyWashington,DC20585

    StrategicSustainabilityPerformancePlanDiscoveringSustainableSolutionstoPowerandSecureAmericasFuture

    ReporttoTheWhiteHouseCouncilonEnvironmentalQualityandOfficeofManagementandBudgetSeptember

    2010

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    2/92

    DepartmentofEnergy

    ii

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    3/92

    DepartmentofEnergy

    iii

    DepartmentofEnergy

    StrategicSustainabilityPerformancePlan

    DiscoveringSustainableSolutions

    toPowerandSecureAmericasFuture

    TableofContents

    Section1:DepartmentPolicyandStrategy.................................................. 1

    I.DepartmentPolicyStatement ................................................................. 1

    II.SustainabilityandtheDepartmentsMission......................................... 2

    III.GreenhouseGasReductionGoals ......................................................... 4

    IV.PlanImplementation............................................................................. 6

    V.EvaluatingReturnonInvestment......................................................... 10

    VI.Transparency....................................................................................... 12

    Section2: PerformanceReview&AnnualUpdate .................................... 13

    I. SummaryofAccomplishments ............................................................. 13

    II.GoalPerformanceReview .................................................................... 17

    1. GOAL: Scope1&2GreenhouseGasReduction ............................. 19

    2. GOAL: Scope3GreenhouseGasReduction.................................... 33

    3. GOAL: ComprehensiveGreenhouseGasInventory........................ 37

    4. GOAL: HighPerformanceSustainableDesign(HPSB)..................... 38

    5. GOAL: RegionalandLocalPlanning ................................................ 43

    6. GOAL: WaterUseEfficiencyandManagement .............................. 46

    7. GOAL: PollutionPreventionandWasteElimination....................... 50

    8. GOAL: SustainableAcquisition ....................................................... 57

    9. GOAL: ElectronicStewardshipandDataCenters ........................... 61

    10.GOAL: DepartmentInnovation....................................................... 65

    Section3:DepartmentSelfEvaluation....................................................... 69

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    4/92

    DepartmentofEnergy

    iv

    Appendices

    Appendix1:Abbreviations........................................................................... 75

    Appendix2:SustainabilityGovernance ....................................................... 77

    Appendix

    3:

    Federal

    Energy

    Management

    Program.................................... 78

    Appendix4:CurrentDOEProjects............................................................... 81

    Appendix5:SummaryofDOEOrders.......................................................... 84

    Appendix6:SourceDocumentReferences.................................................. 87

    ListofTables

    Table1:CriticalPlanningCoordination.......................................................... 9

    Table2:EnergyIntensityProgress............................................................... 13

    Table3:RenewableEnergyProgress ........................................................... 13Table4:WaterIntensityProgress................................................................ 14

    Table5: DOEsFY2009PerformanceinMeetingEPACT2005andEO13423

    Requirements ............................................................................... 15

    Table6:Goal1PlanningTable..................................................................... 33

    Table7:Goal2PlanningTable..................................................................... 36

    Table8:Goal4PlanningTable..................................................................... 43

    Table9:Goal6PlanningTable..................................................................... 49

    Table10:Goal7PlanningTable................................................................... 57

    Table11:Goal8PlanningTable................................................................... 61Table12: Goal9PlanningTable.................................................................. 65

    Table13:EnergySavingsPerformanceContractscurrentlyinplace(1999

    2010)............................................................................................. 83

    ListofFigures

    Figure1: EstimatedDOE2008Scope1and2Greenhouse

    GasInventorybySource................................................................ 4

    Figure2: TotalEnergyUseforDOERealProperty ...................................... 20

    Figure3:EnergyIntensityFY03FY09........................................................... 21

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    5/92

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    6/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page2

    II.SustainabilityandtheDepartmentsMissionSustainabilityisfundamentaltotheDepartmentofEnergysresearchmissionand

    operationsasreflectedintheDepartmentsStrategicPlan. Ouroverarchingmissionis

    todiscoverthesolutionstopowerandsecureAmericasfuture. Weareimplementing

    ourmissionthroughthreestrategicgoals:

    Innovation,tomaintainU.S.globalleadershipinscienceandengineering

    Energy,tobuildacompetitiveandsustainablecleanenergyeconomytosecure

    Americasenergyfuture

    Security,toreducenucleardangersandenvironmentalrisks

    Toaccomplishitsmission,theDepartmentfocusesonachievinganumberofambitious

    strategicpriorities. DOEinvestsinsciencetoachievetransformationaldiscoveries. Itis

    pursuingclean,secureenergy,byreducingourdependenceonoilandchangingthe

    landscapeofenergydemandandsupply. TheDepartmentispositioningtheU.S.tolead

    onclimatechangetechnologyandscience. DOEadvanceseconomicprosperityby

    creatinggreenjobsandincreasingtheNationscompetitiveness. Itcleansupthe

    environmentallegacyleftbynuclearweaponsandnuclearenergyresearchprograms,

    andworkstoprotectnationalsecuritybymaintainingthenationsnucleardeterrentand

    preventingnuclearproliferation.

    TheDOEStrategicSustainabilityPerformancePlan(SSPP)isfundamentallybasedonthe

    Departmentsmission,vision,andstrategicplan. ItisthroughthesesynergiesthatDOE

    willmeetthegoalsofalltheapplicablegreeningthegovernmentexecutiveordersand

    statutes.

    1

    Innovation. Thisstrategicgoalcoversbasicandappliedresearchinscientificprograms

    thatincludebioscience,environmentalandclimatescience,advancedmaterials,and

    eventhefundamentalnatureofmatterandenergyattheatomicandmolecularscales.

    Energyrelatedresearchsupportsthegoalsofalowcarbon,energyefficienteconomy

    throughtransformationalbreakthroughs. Inaddition,DOEconstructsandoperatesthe

    worldspremierscientificfacilitiesandinstrumentsthatresearchersdependonto

    extendthefrontiersofscienceandtechnology.

    Energy. CleanenergyandsustainabilitylieatthecoreoftheDepartmentsmission.

    DOEcontributestoacompetitive,lowcarboneconomythroughscientific

    breakthroughsleadingtonewtechnologiesthatenhanceenergyefficiencyand

    1KeyExecutiveOrdersandstatutesinclude:EO13514FederalLeadershipinEnvironmental,Energy,and

    EconomicPerformance(2009);EO13423StrengtheningFederalEnvironmental,Energy,and

    TransportationManagement(2007);NationalEnergyConservationPolicyActof1978;EnergyPolicyActof

    1992;EnergyPolicyActof2005;EnergyIndependenceandSecurityActof2007.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    7/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page3

    productivitywhilebringingclean,reliable,andaffordableenergytechnologiestothe

    marketplace.

    TheDepartmentchampionssustainabilityinitiativesinsuchdiverseareasasvehicleand

    fueltechnologies,buildingtechnologies,renewableenergytechnologies,andenergy

    efficiencyandstorage. Inaddition,DOEpromotesnuclearpowerasaresourcecapable

    ofmeetingtheNationsenergy,environmentalandnationalsecurityneedsbyresolving

    technicalandregulatorybarriersthroughresearch,developmentanddemonstration.

    DOEalsoleadsnationaleffortstomodernizetheelectricgrid,enhancesecurityand

    reliabilityoftheenergyinfrastructure,andfacilitaterecoveryfromdisruptionsofenergy

    supply.DOEisinvolvedinadvancingcarboncaptureandstorage(CCS)technologies,

    whichcanplayanimportantroleinreducingdomesticGHGemissionswhilepreserving

    theoptionofusinganabundantdomesticfossilenergyresource. DOEiscommittedto

    integratingtheresultsoftheseinitiativesintoouroperationstoachievethegoalsofthe

    relevantEOsandstatutes.

    Security. IssuesofnuclearsafetyandsecurityareatoppriorityasDOEtransformsthe

    Nationsnuclearweaponsstockpileandsupportinginfrastructuretobemoreresponsive

    tothethreatsofthe21stCentury. TheDepartmenthasprovenitsabilitytointegrate

    sustainabilityintoitsnationalsecuritymissionthroughsucheffortsasdesigningand

    operatingsustainablebuildings,despiteoperationalconstraintsthatmaylimit

    opportunitiesforconventionalresourceconservationinthisarea.

    TheDepartmentisalsoresponsibleforthelargestnuclearenvironmentalcleanup

    projectintheworldandiscommittedtocompletingthismissioninasustainable

    manner. TheDepartmentmanagesitspostclosureenvironmentalresponsibilitiesto

    reducewastesitefootprints,ensuresthefutureprotectionofhumanhealthandthe

    environment,andincreasesthenumberoflegacymanagementcustodyandcontrol

    sitesinbeneficialreuse.

    AlthoughthenatureoftheDepartmentsstockpilesecurityandenvironmentalcleanup

    responsibilitiesposechallenges,DOEiscommittedtofindingopportunitieswithinits

    portfoliotoachieveandexceedthesustainabilitygoals.

    DOEwilladdressthesechallengesbypursuingthefollowingkeyobjectives:

    Fosteringacultureofenergyefficiencyandsustainability

    Improvingdataqualitytoinformoperationsanddecisionmaking

    OptimizingallocationofresourcestoachieveEOgoalswhilesafeguardingthe

    mission

    Applyingthebestsustainabilitypractices

    Adoptingemerging,promisingtechnologies

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    8/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page4

    III.GreenhouseGasReductionGoalsTheDepartmentsestimatedScope1and2FY2008baselineis4.6millionmetrictons

    (mT)CO2e(Figure1). AsofMay2010,therewere87buildingsandstructuresscheduled

    forcompletionbyFY2020(indevelopmentatCD2orabove). Althoughsomeofthese

    facilitieswillreplaceolder,lessefficientoperations,thisnewconstructioncould

    increasetheDepartmentsGHGleveltoatleast5.5millionmTCO2e/year. Despitethis

    potentialincreaseinemissions,DOEwillidentifyopportunitiestooffsetthese

    operationswhilestrivingtomeetitsGHGreductiongoals. TheDepartmentalso

    identifiedanestimatedbaselineof748,000mTCO2eforitsScope3FY2008baseline.

    DOE GHG Emissions by Source

    0.0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    Electricity Fossil Fuel Fugitive Gas Transportation

    Emissions(MillionmTCO2

    e)

    Figure1: EstimatedDOE2008Scope1and2GreenhouseGasInventorybySource

    TheDepartmentestablishedthefollowingGHGemissionreductiongoalsforfiscalyear

    (FY)2020:

    ReducingScope1and2GHGby28%(1.3M mTCO2efromtheFY2008baseline)

    ReducingScope3GHGby13%(97,000mTCO2efromtheFY2008baseline)

    DOEsstrategytoachievethesetargetstakesfulladvantageoftheextenttowhich

    emissionsarelinkedtochangesinotherrelatedperformanceparameters,particularly

    energy. ForScope1and2emissions,theDepartmentwill:

    Prioritizeinvestmentinefficiencymeasuresandinfrastructureimprovements

    basedoncarbonintensity

    Reducetheuseofpetroleumbasedfuels

    Deployoperationsandmaintenancebestpractices

    Installassetlevelmetering

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    9/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page5

    Assessandupgradeitsrealpropertyportfoliotomeetthehighperformance

    sustainablebuildingprinciples

    Reducenoncarbondioxide(CO2)fugitiveemissions,specificallysulfur

    hexafluoride(SF6)

    AssessthefeasibilityofusingDOEfacilitiesastechnologyinnovationsitesfor

    carboncaptureandsequestrationorbeneficialreuse.

    Explorelowcarbon,nextgenerationenergytechnologiessuchasfuelcells,

    cogeneration,biomass,otherrenewabletechnologiesandadditional

    technologiesasdeveloped.

    TheDepartmentofEnergymaintainsoneofakindmissionessentialfacilities

    (accelerators,lightsources,nuclearprocesses,petroleumreservesandsupercomputing

    facilities)thatareinherentlyenergyand/orwaterintensive.Toaddresstheseunique

    sustainabilityissues,theDepartmentwillestablishinternalexperttransformation

    teams,accountabletoeachUnderSecretary,todetermineopportunitiestoimprovethe

    energy

    and

    water

    use

    efficiency

    of

    these

    facilities.

    The

    Department

    will

    establish

    a

    processtoaccountfor,andreporttheirenergy,waterandGHGcontribution/reduction

    concurrentwithitsnormalfacilitiesportfolio. DOEwillconductinternaldepartmental

    discussionstodeterminehowgoalswillbemetwithoutaffectingmission

    accomplishment.

    ToreduceitsScope3emissions,theDepartmentwill:

    Expandtheuseofteleconferencing,videoconferencing,andwebbased

    meetingstoreduceemployeeairtravel

    Reduce

    transmission

    and

    distribution

    (T&D)

    losses

    through

    on

    site

    power

    generation

    Reducewastegenerationbyincreasingsustainablepurchasingandrecycling

    ThefullbenefitofalleffortstoreduceGHGemissionswillberealizedwhenthe

    Departmentscorporatecultureembracesthefullrangeofsustainablepractices. Tothis

    end,theDepartmentisstrengtheningitscommitmenttoresourceconservationasa

    corevalue. AllDOEorganizations,includingtheirFederalandcontractorpersonnel,are

    expectedtoexhibitsustainablebehavior,whichcontributestothisSSPP.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    10/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page6

    IV.PlanImplementationa.InternalCoordinationandCommunication

    TheDepartmentestablishedagovernancemodel(seeAppendix2)topreparetheSSPP

    andbeginimplementationoftheEO. Themodelreflectsthedecentralizednatureof

    DOEsoperationalactivities,anddrawsinthemaximumamountofinternalexpertise

    andoperationalperformancedata. Itprovidesbroadrepresentationfrom

    Headquarters,DOEsites,andDOEcontractors,andfosterseffectivecommunicationand

    coordination. Themodel,graphicallyillustratedinAppendix2,includesthefollowing

    elements:

    SeniorSustainabilitySteeringCommittee(SSSC). TheDeputySecretaryistheSeniorSustainabilityOfficer(SSO)andchairsthiscommitteecomprisedofthe

    UnderSecretaries,ChiefFinancialOfficer(CFO),GeneralCounsel(GC),Director

    oftheOfficeofManagement,ChiefHealth,SafetyandSecurityOfficer,andthe

    AssistantSecretaryforEnergyEfficiencyandRenewableEnergy. TheSSSCaligns

    DOEbusinesspracticeswiththegoalsoftheEOsandrelatedstatutes.

    SustainabilityIntegrationTeam(SIT). ThecommitteeiscochairedbyaseniormanagerfromHeadquartersandfromFieldOperations,andincludes

    representativesfromvariousDOEorganizations. WorkingGroupcochairs

    participateinSITdiscussions. TheSITsupervisedthedevelopmentoftheinitial

    SSPP. ThisteamdiscussedandresolvedissuesrelatingtotheSSPPhoweverhad

    nolineauthoritytodirectorimplementpolicy. Thefunctionandorganizational

    placementoftheSITissubjecttochange.

    WorkingGroups(WG). WorkingGroupsarecomprisedofmembersfromHeadquarters

    and

    from

    Field

    Operations.

    They

    provide

    subject

    matter

    expertise

    totheSIT.

    ImplementationandcoordinationoftheSSPPwilloccurthroughexistingDOElinesof

    authority. Inaddition,theFieldManagementCouncil,NationalLaboratoryDirectors

    Council,EnergyFacilitiesContractorsOperationsGroup,communitiesofpractice,

    assistancenetworksandworkinggroupswillenhancethecommunicationofPlan

    implementation. TheDepartmentsdirectivessystemwillincorporateand

    institutionalizeimplementationproceduresbywhichDOEwillmeetSSPPgoals.

    Forlongtermimplementationandoversight,theDepartmentwillestablisha

    SustainabilityPerformanceOffice(SPO)tocoordinatecorporateoversight,foster

    behaviorchange,evaluateperformance,facilitateinformationmanagement,andreport

    progresstowardsustainabilitygoals. TheSPOwillsupporttheDeputySecretaryintheir

    roleastheSSO,aswellastheUnderSecretaries,DOEsites,andotherofficesas

    appropriate. TheSPOwillbestaffedwithfulltimeequivalentseniorlevelprofessionals.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    11/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page7

    b.CoordinationandDisseminationofthePlantotheField

    TheSSPPwasdevelopedwithsignificantparticipationfromHeadquarterselements,

    fieldrepresentatives,andDOEcontractors. Assuch,alargenumberofkeypersonnel,

    representingacrosssectionoftheDepartment,wereinvolvedinthediscussions,

    analysesanddecisionmakingassociatedwiththisPlan.

    Atthesitelevel,theDepartmentwillbuildontheEnvironmentalManagementSystem

    (EMS)process,requiredbyEO13423andalreadyinplaceatitssites,toimplementthe

    goalsarticulatedinthisPlan.

    c.Leadership&Accountability

    TheSecretaryispersonallycommittedtoachievingtheEOandstatutorytargetsandis

    leadingtheefforttochangetheDepartmentsculturetointegratesustainabilityintoall

    DOEoperationaldecisions. TheSecretarysdesignationoftheDeputySecretaryasSSO

    demonstratestheDepartmentshighlevelcommitmenttosustainability. Inaddition,

    the

    establishment

    of

    the

    SSSC

    and

    the

    designation

    of

    the

    SSO

    as

    its

    chair,

    ensures

    continuedseniorlevelattentiontoachievingsustainabilitygoals. Further,senior

    leaders,managers,staff,andDOEcontractorswillbeheldaccountablecommensurate

    withtheirresponsibilitiesforperformanceundertheEOsandrelatedstatutes.

    ThethreeUnderSecretarieswillbeaccountableforallplanning,resourcing,

    implementation,andreportingtoachievesustainabilitygoalswithintheirorganizations.

    Internalsustainabilityscorecardswillassessthelevelofsuccessateachlevelofthe

    Department(individualsites,programs,andUnderSecretary). Thesescorecardswillbe

    reviewedbytheSSOtoevaluateperformanceanddeterminebestpathstoward

    meetingsustainabilitygoalsonaregularbasis.

    d.DepartmentPolicyandPlanningIntegration

    TheDepartmenthasseveralmechanismsinplacewithinwhichtheSSPPwillbe

    integratedwithexistingpolicyandplanningefforts. Forexample,theSSPPisakey

    initiativewithintheEnergygoaloftheDepartmentsStrategicPlan. Executionofthe

    SSPPwillalsobeintegratedintotheDepartmentsperformanceplanning,budget

    formulationandexecutionprocesses. Inaddition,theSSPPwillbelinkedtopolicy

    initiativesprimarilyemanatingfromtheDOEOfficeofEnergyEfficiencyandRenewable

    Energy. Table1providesdetailedinformationonthelinkagetootherpolicyand

    planningmechanisms.

    e.DepartmentBudgetIntegration

    ConsistentwiththeobjectivesofEO13514,theDepartmentiscommittedtofurther

    integratingtheprinciplesofsustainabilityintoitsdecisionmakingandbudget

    developmentprocesses. Theannualbudgetprocesswillbeinformedbythegoalsofthe

    SSPP,startingattheUnderSecretarylevelandprogressingthroughtheProgram

    SecretarialOffices(PSO)tothesites. FutureinternalDOEbudgetguidancewillinclude

    informationontheimportanceofsustainability,GHGemissionsreduction,andresource

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    12/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page8

    conservation. TheDepartmentwillalignitssitelevelenvironmental,energy,andreal

    propertyplanningsystemstoelevatesustainabilityinsitemanagementandbudgeting

    processes.

    Workingwiththeirprogramoffices,siteswillcontinuetoutilizeenergysavings

    performancecontracts(ESPC)andutilityenergyservicecontracts(UESC)aspractical.

    ESPCprojectsthatrequireappropriatedfundingpaymentsmaybesubmittedthrough

    theDOEbudgetprocess.

    f.MethodsforEvaluationofProgress

    DOEwillutilize,integrate,andstreamlineexistingDepartmentdatacollection

    mechanismstoevaluateprogresstowardmeetinggoalsfromEOsandrelatedstatutes,

    including:

    PollutionPreventionTrackingandReportingSystem(PPTRS),collectsenvironmental,

    purchasing,

    and

    best

    practices

    data.

    EnergyManagementSystemversion4(EMS4),collectssiteenergyandwaterconsumptionandcosts.

    FederalAutomotiveStatisticalTool(FAST),collectsfleetinventoryandfueluse. ConsolidatedEnergyDataReport(CEDR),collectsadditionaldataonmetering

    requirements,wateruse,renewableenergygenerationandpurchases,and

    sustainablebuildings.

    SiteSustainabilityPlanPerformanceReporting,collectsdataonsiteidentifiedsustainabilityprojectsandsupportsEnergyIndependenceandSecurityAct(EISA)

    Section432compliance.

    IntegratedFacilities

    Infrastructure

    (IFI)

    Crosscut,

    identifies

    the

    resource

    requirementsassociatedwithTenYearSitePlanimplementation.

    TenYearSitePlans(TYSP),collectsplannedadditionsorchangestotherealpropertyportfolio.

    FacilitiesInformationManagementSystem(FIMS),collectsdataconcerningrealpropertyattributesanduse.

    DOEwilldevelopandpromulgateinternalDOESustainabilityScorecardstotrackprogram

    andsiteperformancetowardsmeetingtheSSPPgoals. Thisscorecardwillbedeveloped

    anddisseminatedforinternalreviewandcommentduringthefirstpartofFY2011. DOE

    willalsoprepareDOEssemiannualreporttoOMBandCEQinresponsetothe

    sustainabilityscorecardprocess.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    13/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page9

    Table1:CriticalPlanningCoordination

    ThefollowingtableshowsthelongtermintegratingrelationshipbetweentheSSPPand

    otherplanningandreportingeffortsusedbyDOE. AYesmeanstheSSPPhasbeen

    integratedintothesubjectreport,Pmeansitwillbeintegratedwithinthenextfiscal

    year,Nomeansithasnotyetbeenplannedforintegration,andN/Ameans

    integrationisnotapplicableornotappropriate.

    OriginatingReport/Plan

    Scope1&2GHG

    Reduction

    Scope3GHGReduction

    DevelopandMaintain

    AgencyComprehensive

    GHGInventory

    High

    Performance

    SustainableDesign/

    GreenBuildings

    RegionalandLocal

    Planning

    WaterUseEfficiencyand

    Management

    PollutionPreventionand

    WasteElimination

    SustainableAcquisition

    ElectronicStewardship

    andDataCenters

    DepartmentInnovation

    GPRAStrategicPlan Yes Yes N/A Yes P P P P Yes Yes

    CircularA11300s N/A N/A N/A No N/A N/A N/A Yes No N/A

    AnnualEnergyData

    ReportYes Yes Yes N/A N/A Yes N/A N/A N/A N/A

    EISASection432Facility

    Evaluations/Project

    Reporting

    Yes N/A N/A No N/A Yes N/A N/A Yes Yes

    Budget P P P P P P P P P P

    AssetManagementPlan

    /3YearTimelineP N/A N/A No N/A N/A N/A N/A N/A N/A

    CircularA11Exhibit53s N/A N/A N/A N/A N/A N/A N/A No No N/A

    OMB

    Scorecards

    N/A

    N/A

    N/A

    Yes

    N/A

    Yes

    N/A

    Yes

    Yes

    N/A

    DOE'sAnnualFederal

    FleetReporttoCongress

    andthePresident

    Yes N/A Yes N/A Yes N/A N/A Yes N/A Yes

    DataCenter

    ConsolidationPlanN/A N/A N/A P N/A N/A N/A P P P

    Environmental

    ManagementSystemYes P P Yes No Yes Yes Yes Yes P

    SiteSustainabilityPlans P P P Yes P Yes P Yes P No

    HighPerformanceand

    SustainableBuildings

    ImplementationPlan

    P N/A N/A Yes P Yes N/A P N/A N/A

    Affirmative

    ProcurementPlanfor

    GreenPurchasing

    No P N/A Yes No Yes Yes Yes Yes No

    USClimateChange

    TechnologyProgram

    StrategicPlan(2006)

    Yes Yes Yes Yes Yes N/A N/A Yes Yes Yes

    FederalGHGAccounting

    &ReportingGuidanceYes Yes Yes N/A N/A Yes Yes Yes N/A Yes

    FederalProcurement

    DataSystemN/A N/A N/A P N/A N/A N/A Yes P N/A

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    14/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page10

    V.EvaluatingReturnonInvestmentTheDepartmentwillestablishaprocesstoprioritizeprojectsthatmostcosteffectively

    meettheSSPPsenergyandenvironmentalgoals,whilegeneratingthegreatestcost

    savingsforDOEasitexecutesitsmission. Eachprojectconsideredforfundingwillbe

    evaluatedfirstoneconomicReturnonInvestment(ROI)andthenonanROIthat

    includesenvironmentalandsocialbenefits. DOEwillcalculatetheROIofresource

    conservationandGHGreductionprojectsasdescribedbelow.

    FinancialROIisoneofseveralkeyfactorsinprioritizingprojectsanddeterminingthe

    abilitytoimplementtheseprojects(especiallyfordirectappropriationproposals). In

    additiontothecomponentsofROI,DOEmayconsider(althoughisnotlimitedto)the

    followingcriteriawhenassessingprojects:

    CostperunitcontributiontotheSSPPenergyandenvironmentalgoals

    Program/siteprioritiesandfutureplansinsupportofitsmissions

    Localandregionalplanningfactors

    Currentsiteinfrastructureandplannednewconstruction

    Siteenergyorwaterconsumptionandcosttrends

    Publicvisibility(DOEplacesvalueonshowcasingtechnologiesdeveloped

    throughitsresearchefforts)

    Riskmanagementconsideration(e.g.,environmentalremediationfrom

    unplannedspillsandreleases)

    Safetyandhealth

    Continuityofoperations

    Socialcostofcarbon(SCC)

    a.EconomicLifecycleCost/ReturnonInvestment

    Whenevaluatingproposedprojects,DOEwillusearigorouscostbenefitanalysisfor

    selectingprojectsandinitiatives. ReturnonInvestmentandNetPresentValue

    (NPV)willbecalculatedperOMBCircularA94GuidelinesandDiscountRatesfor

    BenefitsCostAnalysisofFederalPrograms. Otherfinancialcalculationsmaybe

    performedtodeterminepaybackperiod,internalrateofreturn(IRR),andproject

    costeffectivenesswithregardtoGHG,energyandwatersavingsovertime.

    b.SocialCosts&Benefits

    BeyondafinancialROI,theDepartmentwillconsiderthesocialcostsofGHG

    emissionsandthebenefitsofabatement. ThesesocialcostswillfactorintotheROI

    analysisthroughtheuseofanominalSCCasprovidedinSocialCostofCarbonfor

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    15/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page11

    RegulatoryImpactAnalysisunderEO12866.2 The2010SCCvalueof$21.40per

    mTCO2ewillbeusedasanadditionalprojectreviewfactorafteranNPVandother

    financialanalysesarecompleted,anditsvaluewillbeadjustedovertimetoreflect

    inflationandotherrelevantescalationrates.

    c.EnvironmentalCosts&Benefits

    DOEwillcontinuetofactorenvironmentalcostsandbenefitsintoitsROIanalysis.

    PreviousstatutesandEOsmandatingresourceconservationprovideastrong

    frameworktoguidetheDepartmentscontinuingeffortstoreduceitscollective

    environmentalimpact. DOEwillapplylifecycleanalysistoactionswith

    environmentalimpactstorevealtheproportionalityoftheirimplementationcosts

    totheircontributiontotheSSPPenergyandenvironmentalgoals.

    d.MissionSpecificCosts&Benefits

    ManycoreDOEactivitiesarehighlyenergyintensive. Scientifictools(suchas

    accelerators,

    synchrotron

    light

    sources,

    reactors

    and

    supercomputers),

    materials

    developmentprocesses,andenvironmentalremediation(suchastankwaste

    treatment),requirereadyaccesstoreliableenergyandbackuppoweratreasonable

    costs. DOEwilltakeproactivestepstoaddresstheenergysupplysourcesatthese

    facilitiestomaximizeGHGreductionopportunities.

    Incompletingitsenvironmentalresponsibilities,DOEwillconsideropportunitiesto

    acceleratedeactivationanddecommissioning(D&D)ofexcessfacilitiesaswellas

    opportunitiestodeploymoresustainableD&Dtechnologiessuchasinsitu

    decommissioning. DOEwillalsocontinuetoincorporategreenremediation

    practicesintoitsenvironmentalcleanupprogram.

    Inaddition,DOEwillevaluatetheuseofmissionspecificresearch,suchasenergy

    efficiencyandrenewableenergy,forprojectsthatcanbedemonstratedatDOE

    sites. SuchdemonstrationscanputDOEresearchintopractice,increaseDOEenergy

    savingsandrenewableenergy,andpotentiallyreduceassociatedcostsforDOEand

    commercialtechnologytransfer.

    e.Operations&MaintenanceandDeferredInvestments

    DOEsitemanagersareresponsibleforimplementingeffectiverealproperty

    managementprocessesandproperapplicationofoperationsandmaintenance(O&M)

    funds.

    Maintenance

    and

    repair

    activities

    are

    prioritized

    based

    on

    many

    factors

    including

    safety,qualityoflife,protectionofassets,andprotectionoftheenvironment. The

    Departmentmaintainsabacklogofdeferredmaintenance(i.e.,maintenanceactivities

    thatweredeferredbeyondtheiroptimaltimeforexecution). Certaindeferred

    2See

    http://www1.eere.energy.gov/buildings/appliance_standards/commercial/pdfs/smallmotors_tsd/sem_fin

    alrule_appendix15a.pdf

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    16/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page12

    maintenanceresultsinincreasedenergyusageandgeneratesadditionalrepaircosts

    (e.g.,aleakingroofwilldamageinternalbuildingcomponentsifnotfixed). Site

    Managerswillconsiderenergy,waterandGHGreductionopportunitieswhen

    prioritizingmaintenance,repairanddeferredmaintenanceactivities.

    f.ClimateChangeRiskandVulnerability

    ClimatechangeisexpectedtoaffecttheUnitedStatesinanumberofways.

    Warmingoceanswillraisesealevels,whichcouldleadtonegativeconsequencesfor

    DOEcoastalsites. Climatechangemayalsochangepatternsofrainfall,resultingin

    greaterwaterscarcityinpartsofthecountry. Increasedwaterscarcityposesthe

    greatestrisktoDOEsitesthatrelyonlargeamountsofwaterforwasteprocessing

    andpowergeneration,particularlythoseindrierregionsofthecountry. Climate

    changemayalsoincreasethefrequencyandintensityofstorms,whichmayleadto

    greaterpotentialdamagetoDOEsitesandanincreasedlikelihoodofpowerloss,

    localizedflooding,andotherthreatstobusinesscontinuityandinfrastructure. DOE

    will

    study

    and

    consider

    these

    concerns

    as

    environmental

    factors

    when

    evaluating

    projectprioritization.

    g.AlternativeFundingApproaches

    TheDepartmentutilizesthirdpartyfinancingmechanismssuchasESPCsandUESCs

    tofinanceenergyefficiencyandconservationmeasures. Byusingtheseapproaches,

    theDepartmentleveragesprivatesectorfinancingandexpertise. Whenentering

    intoalternativefinancingarrangements,DOEwillworktoensurereasonablecost

    savingsestimates,properprojectimplementation,soundcontractoversight,and

    accuratemeasurementandverificationofsavings.

    VI.TransparencyTheDepartmentcommitstotransparentcommunicationonsustainabilitywithboth

    internalandexternalaudiences. KeepingstakeholdersapprisedofDOEprogressand

    resultsisconsistentwithDOEsOpenGovernmentPlan3andisessentialtoachievingthe

    requisiteculturalchangeneededtointegratesustainabilityasaDepartmentcorevalue.

    TheDepartmentwillengageintwowayinternalcommunicationtoinformcontinuous

    improvementintheimplementationoftheEOsandrelatedstatutes. Thiswillinclude

    gatheringdataandoperationalexperiencefromDOEprogramsandsitesthrough

    reportingprocesses,anddisseminationofinternalscorecards.

    InformationwillbeaccessiblethroughDOEswebsitewheretheSSPP,andassociated

    milestones/performanceinformation,willbeposted. DOEwillprovideperiodicupdates

    onthestatusofprograms,initiativesandaccomplishmentsassociatedwiththeSSPP.

    3http://www.energy.gov/open/documents/DOE_OGI_Plan_07Apr2010.pdf

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    17/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page13

    Section2: PerformanceReview&AnnualUpdate

    I. SummaryofAccomplishmentsThe

    Department

    has

    made

    considerable

    progress

    in

    its

    sustainability

    efforts

    under

    the

    requirementsofEO13423andrelatedstatutes. Theseaccomplishmentsare

    summarizedbelowandincludediscussionofsuccessfulprograms,lessonslearnedand

    anticipatedchallenges.

    ProgresstowardFacilityEnergyandWaterGoals

    InFY2009,DOEreporteda17.4%decreaseinenergyintensitycomparedtoFY2003for

    facilitiessubjecttothestatutorygoalof12%,asnotedinTable2. Thisreductionincludes

    purchasesof778billionBritishThermalUnits(Btu)ofrenewableenergy. Withoutthese

    purchases,DOEsreductionis14%,stillsurpassingthe12%goalfortheyear.

    Table2:EnergyIntensityProgress

    EnergyManagementRequirement FY2003Btu/GSF FY2009Btu/GSF %Change2003 2009 FY2009GoalTarget

    Reductionoffacilityenergy

    intensity

    225,483 186,355 17.4% 12.0%

    Thereductioninenergyintensityistheresultofenergyconservationmeasures,reduced

    missionrelatedactivitiesandthedownsizingofsomeoperationsandfacilities. As

    manpowerisreducedandfacilitiesareclosed,effortstoconsolidateoperationsand

    minimizeenergyuseinvacatedbuildingswillcontinue.

    DuringFY2009,DOEsitesuseofrenewableelectricenergywas4.7%oftotalelectricity

    use,surpassingthegoalof3%forFY2009(seeTable3). OfDOEstotal236Gigawatt

    hours(GWH)ofrenewableelectricityuse,225GWHcamefromnewrenewableenergy

    (RE)sources(developedafterJanuary1,1999).

    Table3:RenewableEnergyProgress

    RenewableEnergyRequirement RenewableElectricityUse

    (MWH)

    TotalElectric

    Use

    (MWH)

    REas%of

    TotalElectric

    Use

    FY2009Goal

    Target

    Eligible

    renewable

    electricity

    use

    asapercentageoftotal

    electricityuse

    235,945.0

    4,971,650.0

    4.7%

    3.0%

    InFY2009,DOEfacilitiesgeneratedabout1,900MWHofrenewableelectricityfrom141

    onsiteprojects,orapproximately0.8%ofDOEstotalofeligiblerenewableenergy

    (purchasesarethemainsource). Inadditiontorenewableelectricenergy,DOEused

    46.2billionBtuofrenewablebiomassgasandthermalenergyinFY2009. Eight

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    18/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page14

    renewablethermalenergyprojects,notcountedunderthestatutoryrenewableenergy

    goal,produced182billionBtuofenergy.

    ThereareseveralsignificantprojectsbeingpursuedorunderwaythatwillincreaseRE

    generatedatDOEsites. Constructionstartedonabiomasscogenerationplantatthe

    SavannahRiverSite,whichwillreplaceanexistingoldandinefficientcoalplant,and

    saveanestimated100,000metrictonsofCO2annually4and1.4billiongallonsofwater.

    TwoadditionalbiomasssteamplantsareunderconstructionatSavannahRiver,

    replacingexistingfossilfuelfiredplantsandreducingthemilesofsteampipingneeded

    tomovetheheat. Abiomasssteamgenerationplantisscheduledtobeoperationalin

    2011atOakRidgeNationalLaboratory(ORNL). Itwillreplacefouragingnaturalgas

    firedboilersandreduceannualCO2emissionsbyover55,000metrictons,alongwith

    significantreductionsinairpollutants. TheNationalEnergyTechnology

    Laboratoryinstalledsatellitebiomasslowpressuresteamandhotwaterboilersin

    variousDOEbuildingsatitsPittsburgh,Pennsylvaniasite,replacingtheexistinglandlord

    operated

    coal

    fired

    high

    pressure

    central

    steam

    plant.

    DOE

    will

    continue

    to

    identify

    renewableenergyprojectsand/ortechnologydemonstrationsatsitesthatcan

    contributetosustainabilitygoals.

    AsshowninTable4,DOEsitesreporteda2.6%decreaseinwaterintensityforFY2009

    comparedtoFY2007,howeverthisdoesnotmeetthe4%reductionrequiredbyEO

    13423. Theintensityreductionoverthepastyearispartiallyduetoreducedmission

    relatedactivities,implementationofbestmanagementpracticesandwater

    conservationmeasures(e.g.,leakdetectionandrepair).

    Table4:WaterIntensityProgress

    WaterIntensityReductionGoal FY2007Gallon/GSF

    FY2009

    Gallon/GSF

    %Change

    2007 2009

    FY2009Goal

    Target

    Reductioninpotablewater

    consumptionintensity

    64.8 63.1 2.60% 4.00%

    DOErecognizesthepotentialtosavemoneyandnaturalresourcesthroughwater

    conservation. DOEencouragesitsfieldofficesandsitestoincludewatermanagement

    planswithintheirfacilitymanagementplans. DOEwillworktoincreaseefforts

    associatedwithwaterconservationasdescribedinGoal6.

    TheDepartmentrecentlyfundedmanyfacilityefficiencyimprovementsthroughits

    aggressiveuseofESPCs. Theseinvestmentstotaled$139millioninFY2008and$176

    4ThoughtheplantunderconstructionisestimatedtoresultintheGHGsavingsmentioned,thecontractor

    hasretainedrightstothecarboncredits,sotheGHGsavingsmaynotcounttowardDOEsGHG

    reductiongoals. TherenewableenergyattributesofthegenerationareretainedbyDOEunderthe

    contract,sotheprojectwillcounttowardtheDepartmentsrenewableenergygoal.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    19/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page15

    millioninFY2009(33%and43%ofannualfacilityenergycosts,respectively). DOEwill

    continuetopursuealternativefinanceprojectsasappropriate.

    ProgresstowardFleetTransportationGoals

    DOEdemonstratescompliancewithrequirementstodecreasepetroleumuse,increase

    useofalternativevehiclefuels,andtheotherrequirementsforcoveredfleetvehiclesas

    showninTable5.

    Table5: DOEsFY2009PerformanceinMeetingEPACT2005andEO13423Requirements

    Authority/

    Mandate PerformanceMeasure Goal/Requirement

    DOEPerformance

    inFY2009

    EnergyPolicy

    Act(EPACT)

    1992

    Alternativefuelvehicle

    (AFV)acquisitions

    75%ofthe733covered

    lightdutyvehicles(LDV)

    acquiredinFY2009mustbe

    AFVs

    Acquired1,237AFVsand

    earned169additional

    credits1

    foratotalof

    1,406creditsor192%of

    covered

    acquisitions.

    Compliant

    EO13423 Reduceconsumptionof

    subject2petroleumby2%

    annuallythroughtheendof

    FY2015fromFY2005

    baseline3

    Reduceconsumptionof

    subjectpetroleumtobelow

    FY2009targetof6,798,690

    gasolinegallonequivalents

    (GGE)

    Reducedconsumptionof

    subjectpetroleumto

    6,185,765GGE(8.3%

    belowtheFY2009

    target).Compliant

    Increaseannualalternative

    fuelconsumptionby10%

    (compoundedannually)

    throughtheendofFY2015

    fromFY2005baseline2

    Increasealternativefuel

    consumptionequaltoor

    aboveFY2009targetof

    913,276GGE

    Increasedalternativefuel

    consumptionto

    1,307,721GGE(43.2%

    overtheFY2009target).

    Compliant

    EPACT2005,

    Section701

    AlternativefueluseinAFVs OperatealldualfuelAFVs

    onalternativefuelunless

    theAFVisgrantedawaiver

    forfuelavailabilityorcost

    Used340GGEof

    alternativefuelpernon

    waivereddualfuelAFV.

    Compliant

    1Creditsearnedforbiodieseluse.

    2Subjectpetroleumincludesthepetroleumusedinalllightduty,mediumduty,andheavyduty

    vehicles,unlesssuchvehiclesareexemptedfromEO13423(e.g.,lawenforcement,emergency,and

    militarytacticalvehicles,andvehiclesoperatedoutsideoftheU.S.).3DOEsFY2005subjectpetroleumbaselineis7,389,881GGEandFY2005alternativefuelbaselineis

    623,779GGE.

    TheDepartmentcontinuestotransformitsvehiclefleettoutilizealternativefuels. In

    ordertofurtherreduceGHGemissionsfrompetroleumuse,DOEisexploringoptionsto

    transformitsfleet. InApril2010,DOEannouncedthatitwillleverageEO13514to

    doubleitshybridvehiclefleet. Replacing850DOEvehicleswithhybridvehicleswill

    bringthetotalnumberofhybridsattheDepartmentto985,whileDOEcontinuesto

    reducetheoverallsizeofitsvehiclefleet.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    20/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page16

    ProgresstowardOtherSustainabilityGoals

    InFY2009,DOEattainedastatusofGreenonthreeoutoffourenvironmental

    stewardshipperformancemetricsontheOMBscorecard: EnvironmentalManagement

    Systems(EMS),AffirmativeProcurementProgram,andElectronicStewardship.

    ThroughitsongoingimplementationofrobustsitelevelEMS,DOEinstitutionalizedan

    effectiveframeworkforimplementingsustainabilitythroughoutthecomplex. Allsites

    havefullyimplementedEMS,mostofwhichalreadyaddressmanyEO13514goals.

    EnvironmentalManagementSystemsprovideastructureforthesitelevelcrosscutting

    andmultifunctionalcoordinationnecessarytoplanfor,andachieve,theDepartments

    sustainabilitygoals.

    DOEcontinueditsleadershipinFederalelectronicsstewardshipinFY2009. Over97%of

    computersleasedorpurchasedbyDOEwereElectronicProductEnvironmental

    AssessmentTool(EPEAT)registered;over95%ofDOEsitesextendedlifespansof

    computers

    and

    monitors

    to

    at

    least

    48

    months;

    and

    over

    99%

    of

    DOE

    end

    of

    life

    or

    surpluselectronicswerereusedorrecycled. Inaddition,over90%ofDOEsites,

    representingover95%ofDOEFederalandcontractorpersonnel,employedpower

    managementoncomputersandmonitors.

    DuringFY2009DOEwasunabletodemonstrateimplementationofFederalGuiding

    PrinciplesforSustainableDesign(GP)in3%ofitsnew,existingandleasedenduring

    buildingslargerthan5,000squarefeet. DOEsstatuschangedfromGreentoRed

    withonly1.2%ofeligiblebuildingsmeetingtheGP. DOEhascommittedtocompletinga

    largenumberofbuildinglevelevaluations(FY20112012),andwillcontinuenumerous

    projectstobringadditionalbuildingsintoGPconformance. TheDepartmentisclosely

    monitoringthiseffort,andwillcontinuetoprovidetechnicalsupportandtrainingtoits

    ProgramOfficesandsitestoincreasetherateatwhichbuildingscanmeettheGPs.

    DOEsiteshavealreadyimplementedseveralgreenwastemanagementsystems. All

    siteshaverecyclingprogramsinplace,reportinginFY2009a49%diversionofwaste

    Departmentwide. Twentyonesiteshaverecyclingprogramsthatcovercompostable

    andorganicmaterials,divertingover10,000metrictonsfromlandfillsinFY2009.

    DOEpurchasesofrecycledcontentproductsexceeded$38MinFY2009. Sitesreported

    anincreaseinthevarietyandnumberofsitespurchasingbiobasedproducts,andover

    98%

    of

    DOE

    Federal

    and

    contractor

    personnel

    reported

    preferences

    for,

    and

    purchases

    of,ENERGYSTARproducts. Sitesalsoreportedapreferenceforandpurchaseof

    FederalEnergyManagementProgram(FEMP)designatedandWaterSenselabeled

    products.

    FederalEnergyManagementProgramActivities

    UniqueamongotherFederalagenciesisthecoordinatingandsupportroleofDOEs

    FederalEnergyManagementProgram(FEMP). FEMPsmissionistofacilitatethe

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    21/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page17

    FederalGovernment'simplementationofsound,costeffectiveenergymanagementand

    investmentpracticestoenhancethenation'senergysecurityandenvironmental

    stewardship. Giventhestrongassociationbetweengreenhousegas(GHG)emissions

    andenergymanagement,FEMPhasbeenspecificallytaskedunderEO13514toprovide

    criticalsupporttotheWhiteHouseCouncilonEnvironmentalQuality(CEQ)in

    implementingtheOrderincludingprovidingdetailedrecommendationsforGHG

    accountingandreporting,guidanceonFederalfleetmanagement,technicalassistance

    toagencies,andchairingseveralinteragencyworkinggroups. Currently,FEMPalsohas

    akeyroleinsupportingDOEsinternalsustainabilityefforts. FurtherdetailsonFEMPs

    Governmentwideandinternalsupportroles,recentactivities,andaccomplishments

    relatedtoEO13514areprovidedinAppendix3.

    II.GoalPerformanceReviewTheStrategy. To

    achieve

    the

    goals

    outlined

    in

    this

    plan,

    and

    achieve

    the

    Secretary

    of

    EnergysintenttodemonstrateSustainableScience,theDepartmentwillorganizeits

    managementandimplementationeffortsinfourmajorareas. First,DOEwillstrengthen

    itsinternalmanagementstructuretoenhancedecisionmaking,analysisand

    accountability,withsignificantresponsibilitiesdelegatedtotheUnderSecretariesbut

    performancetrackedcentrally. Second,theDepartmentwillundertakeawholesale

    assessmentofitssustainabilityposture,collectingcriticalenergyandefficiencydata

    acrosstheentirecomplexinordertoinformfutureinvestmentsdecisions. Third,the

    Departmentwillputinplacearobustgoalattainmentandperformancemanagement

    systembasedonmetering,benchmarkinganddocumentedefficiencygains. Finally,in

    recognitionthatgoalattainmentis,attheendoftheday,aquestionnotonlyof

    technologyanddata,butofleadership,theDepartmentwillestablishdedicatedefforts

    tochangeindividualandcollectivebehaviorthroughincentiveprogramsandperiodic

    reportingtotheDepartmentsuppermostmanagement. Allofthiswillbe

    accomplishedasrapidlyaspossiblewhilemaintainingacommitmenttopublic

    transparencyandmissionaccomplishment.

    DOEOrganization.UndertheDeputySecretary(whoisalsotheSSO)aretheUnder

    SecretaryforNuclearSecurity,theUnderSecretaryforScience,andtheUnderSecretary

    forEnergy. ProgramSecretarialOfficesreporttotheUnderSecretaries. TheNational

    NuclearSecurityAdministration(NNSA)isalignedundertheUnderSecretaryforNuclear

    Security. TheOfficeofScienceisalignedundertheUnderSecretaryforScience. All

    othermajorPSOsarealignedundertheUnderSecretaryforEnergy. TheManagement

    PSO,whichisresponsiblefortheHeadquartersoffices,andthefourPowerMarketing

    AdministrationsworkdirectlyfortheOfficeoftheSecretary. AllDOEsitesarealigned

    underaPSO.

    NewPositions. DOEwillestablishaSustainabilityPerformanceOffice(SPO)toassistthe

    SSOintheperformanceofthisplan. Theofficewillfocusondatacollection,analysis,

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    22/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page18

    reporting,providingexpertiseasnecessary,andotherdutiesasassigned. TheSPOmay

    requirenewFTEs. TheFY2011SSPPwillprovideamoredetaileddiscussionofmission,

    andorganizationalplacementofthisoffice.

    EnvironmentalManagementSystems. DOEwillcontinuetouseitsexistingEMSasthe

    overarchingplanningandmanagementprocesstoachievethesustainabilitygoalsofthe

    EOsandrelatedstatutes. TheDeputySecretaryorderedtheDepartmenttointegrateits

    environmentalandenergymanagementdirectives,includingconformanceto

    InternationalStandardsOrganization(ISO)14001astheDepartmentsstandardfor

    environmentalmanagementsystemsandtherequirementsofEO13514. The

    DepartmentwillpromulgateanOrderinFY2011torequiresitestorevisetheirEMS,as

    necessary,toincorporateactivitiesandprogramstomeetthegoalsandtargets

    identifiedinthisSSPP,toensureconformancewiththeISO14001standard,andto

    provideannualreportstoHeadquartersontheirprogressinachievingtheEOandSSPP

    goals. TheDepartmentwillalsousethisnewOrdertoalignitscorporatepoliciesand

    requirements

    to

    support

    the

    integration

    of

    energy

    use

    reduction

    and

    environmental

    sustainabilityintositeoperationsandactivities.

    SustainabilityTransformationTeams. DOEwillleverageitsscientificexpertisebydirectingtheDOENationalLaboratoriesandsitestocollectivelycollaborateusingthe

    fullsuiteofresourcesattheirdisposal(includingtheexpertiseoflaboratoryscientists

    andengineers)todevelopinnovative,crosscuttingstrategiesformeetingtheExecutive

    Ordergoals. TheSustainabilityTransformationTeamswillaggressivelyaddressDOE

    operations,includinghighenergymissionspecificequipmentandfacilities,toidentify

    opportunitiestoimprovesustainabilityandachievemissionrequirements.The

    strategiesrecommendedbytheTransformationTeamswillbereportedtothecognizant

    UnderSecretariesforusebyallDOEsites. Thesestrategieswillbeintegratedwithand

    alignwiththeSitesongoingsustainabilityplanningefforts.

    SSPPRollOut. TheSSPPwillbeintroducedtoDOEpersonnelthroughawell

    coordinatedrollout. Activitieswillinclude:

    DistributionofamemofromtheSSOtoDOEpersonnelintroducingtheSSPP

    PublicationandpublicdistributionoftheSSPPonaDOEwebsite

    ConveningaGHGsummitofseniorDOEleadership(toincludelaboratoryChief

    OperatingOfficersandChiefFinancialOfficers)

    Verificationthatenergyconservationandrecyclingareincludedinallnewemployeeorientationprograms

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    23/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page19

    1. GOAL: Scope1&2GreenhouseGasReduction

    TheDepartmentsoverarchingmissionistodiscoverthesolutionstopoweringand

    securingAmericasfuture. Assuch,theDepartmenthasdevelopedprogramsand

    fundingapproachesandhasinvestedinarangeoftechnologiesthatincrease

    efficiency,produceclean,renewableenergy,andimprovetransportationefficiency.

    Overtheyears,manysuchtechnologiesweredemonstratedandusedatDOEsites.

    TheseweredeployedunderDOEOrder430.2BandpriorOrders. DOEwillexpand

    theseactivitiesforEO13514withreductionofGHGemissionsastheintegrating

    performancemetrictoincreaseitssustainability.

    EO13514directedeachagencytoselectacombinedScope1and2GHGemissions

    reductiongoal. TheDepartmentselectedacombinedScope1and2GHGemissions

    reductiongoalof28%(fromDOEsFY2008baseline). ToreachthisgoalDOEwill:

    a.

    Improve

    the

    energy

    efficiency

    of

    processes,

    buildings,

    and

    facilities

    b.Increasetheamountofrenewableenergyused,withemphasison

    developmentofrenewableenergygenerationonDOEsites

    c.Reducethefossilfueluseofthevehiclefleet

    d.ReducenonCO2fugitivegasemissionsthatproduceGHG

    Eachofthesestrategiesisdiscussedbelow.

    a. EnergyEfficiencyinProcessesandFacilities:ReduceFacilityEnergy

    Intensity

    DOEsrealpropertyportfolioincludesover10,000buildingsandtrailers

    representingmorethan126Mgrosssquarefeet(GSF)ofofficebuildings,

    laboratories,stagingfacilities,andwarehousesat47majorsitesacrossthe

    country5.

    i.GoalDescriptionEISA2007,asamendedbytheNationalEnergyConservationPolicyAct

    (NECPA),requiresa30%energyintensityreductionforfederalfacilitiesby

    2015(relativetoa2003baseline). Thisgoalisconsistentwiththegoalsetin

    Section2aofEO13423andisincludedinSection1.b.1ofDOEOrder430.2B.

    5DOEcurrentlyownsapproximately22MGSFofspacethatisoutgranted,orleasedtothirdpartiesover

    whichtheDepartmenthasnooperationalormanagementcontrol.Becausetheoutgrantedfacilitiesarenot

    underDOEsoperationalcontrol,theyarenotincludedinDOEsScope1and2GHGinventoryortheSSPP.

    ExamplesincludetheU.S.EnrichmentCorporationsPortsmouth,OhioandPaducah,Kentucky.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    24/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page20

    ii.CurrentStatusFigures2and3illustrateDOEstotalenergyuseandenergyintensity,

    respectively,forDOEsrealpropertyportfoliofrom2003to2009. Thecharts

    showenergysubjecttothe30%energyintensitygoalandtotalenergyuse

    (whichincludesenergyexcludedfromthegoal).

    BytheendofFY2009,DOEhadachievedanenergyintensityreductionof

    14%(17.4%ifRenewableEnergyCertificates[RECs]areincluded). The

    majorityofenergyconservationprojectshavebeenperformedthroughthe

    leveragingofESPCcontracts,aswellastheimplementationofbestpractices

    anddemandsidemanagement.

    DOE Energy Use 2003-2009

    -

    5,000

    10,000

    15,000

    20,000

    25,000

    30,000

    35,000

    2003 2004 2005 2006 2007 2008 2009

    EnergyUse(10^9BTU)

    Goal Subject Buildings Energy Total Energy (Goal Subject + Exc luded)

    Figure2: TotalEnergyUseforDOERealProperty

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    25/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page21

    DOEEnergyIntensityFY0309

    180,000

    185,000

    190,000

    195,000

    200,000

    205,000

    210,000

    215,000

    220,000

    225,000

    230,000

    235,000

    240,000

    245,000

    250,000

    255,000

    260,000

    265,000

    270,000

    275,000

    2003 2004 2005 2006 2007 2008 2009

    EnergyIntensity,

    BTU/SF

    RequiredEnergyIntensity (EI)EIforGoalSubjectEnergyw/oRECsandSourceEnergyCreditEIforGoalSubjectEnergyw/RECsandSouceEnergyCreditEIforAllEnergywithoutRECsorSourceEnergyCredit

    Figure3:EnergyIntensityFY03FY09

    iii.SpecialConsiderationsAchievingScope1and2GHGreductiontargetsforFY2020willbemore

    challengingthansimplymeetingtheenergyintensityreductiontarget.

    NECPAallowsfortheexclusionofcertainprocessesandfacilitiesfromthe

    energyintensitycalculation. However,theGHGemissionsoftheseloadsare

    notexcludedunderEO13514,andarecurrentlysubjecttothe28%GHG

    reductiongoal.

    DOEcontinuestolookforwaystoreduceprocessloadsatexcludedfacilities

    withoutadverselyaffectingthemissionoftheDepartmentanditsfacilities.

    TheSustainabilityTransformationTeamswillexamineinnovativeapproaches

    toachievingmissiongoalsinalignmentwithSSPPgoals.

    iv.ImplementationMethodsWhilesufficientprojectstomeettheenergyintensitygoalarestillbeing

    identified,

    the

    Department

    will

    focus

    on

    the

    following

    actions:

    Conductingprocessassessments,andenergyandrecommissioning

    audits

    Meteringprocessesandindividualbuildingsforperformance

    diagnostics

    Benchmarkingbuildingperformance,withinternalandexternal

    disclosure

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    26/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page22

    Implementingprojects(energyconservationmeasures[ECM])to

    includerecommissioningofbuildings

    Asapriority,DOEwillconductsiteassessmentsandenergyauditson

    facilitiesandprocessenergyuse. Theseauditsandassessmentswillbeused

    toidentifyprojectstosupportallthegoalsofthisplan,toincludeenergy

    efficiency,coolroofs,andpotentialimplementationofcombinedheatand

    power(CHP)units(withorwithoutbiomassfuels). Theseauditswillcoincide

    withauditsrequiredbySection432ofEISA2007andaDOEsurveyofenergy

    andwaterefficiencytechnologiesinstalledateachsite.

    Overtime,buildingsdepartfromtheirdesignbehaviors. Thesedeviations

    mayoccurfromoperatorintervention,sensordegradationorequipment

    malfunction. Thereturnofabuildingsoperatingsystemstotheirdesign

    conditionwilloftenresultinimprovedenergyefficiency.DOEwillperform

    recommissioning

    assessments

    on

    75%

    of

    its

    buildings

    (in

    terms

    of

    energy

    use)

    asapriority,andwillidentifybuildingsmostinneedofrecommissioning

    measures.

    DOEwillestablishtwospecialpurposeteamstoapply,andassistsite

    personnellearnaboutstateoftheartwaterandenergyauditingtechniques.

    OneteamwillbeformedfromDOEsIndustrialProgramsOfficeandwill

    focusonprocessandindustrialassessments. Amongothertopics,thisteam

    willlookforappropriateopportunitiestoapplyCHPtechnology,andwill

    assistintheperformanceofboilerassessmentstoimproveboilerefficiency

    tofullcompliancewithEPAproposedrulesforboilertuneups/audits. The

    secondteamwillbeformedfromDOEsBuildingTechnologiesProgram

    Officeandwillfocusonbuildingenergy,waterandrecommissioning

    assessments. Lowornocostcorrectivemeasureswillbeimplementedin

    thenearterm,whereascorrectivemeasureswithlargerimpactwillbe

    addressedinfuturebudgetsubmissions. Theseteamswillprovide

    assessmentsandtechnicalassistancetosites,programs,SPOandtheUnder

    Secretariestoenablesharingoftechnicalexpertise,publicandprivatebest

    practices,andaccesstostateoftheartindustrialprocessandbuilding

    assessments.

    Metering

    is

    critical

    to

    resource

    control,

    as

    well

    as

    measurement

    and

    verification(M&V)ofimplementedECMs. Itiscurrentlyestimatedthatonly

    40%ofDOEsbuildingsareindividuallymeteredforelectricity.6 NECPA,as

    amendedbyEPAct2005,requirestheinstallationofelectricalmetersby

    2012,withadvancedelectricalmeterstothemaximumextentpracticable.

    6Meteringguidancecanbefoundat:http://www1.eere.energy.gov/femp/pdfs/adv_metering.pdf

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    27/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page23

    EISA2007mandatesappropriatebuildinglevelmeteringofnaturalgasand

    steamby2016.Electricalmeterinstallationwillremainaneartermpriority.

    DOEwillreevaluate,updateandpromulgateinternalmeteringguidance.

    Siteswilladjusttheirmeteringplansaccordingly.

    ThemajorityofDOEbuildingsfallintooneoftwogroups: amultibuilding

    facility(oftencalledacampus),orstandalonebuildings. DOEsmetering

    philosophydiffersbetweenthesetwogroupsandisdiscussedbelow.

    1) Multibuildingsites

    Forunmeteredbuildingsandprocesses,DOEwillinstallelectricity

    meterssothatatleast90%ofthemultibuildingfacility(interms

    ofenergyuse)ismetered.

    Forunmeteredbuildingsandprocesses,DOEwillinstallnatural

    gasandsteammeters,asappropriate,sothatatleast90%ofthe

    multi

    building

    facility

    (in

    terms

    of

    energy

    use)

    is

    metered.

    2)Standalonebuildings,suchasheadquartersbuildingsinWashington

    DCand GermantownMD,thatarenotpartofmultibuildingfacilitieswill

    bemeteredforelectricity,naturalgas,andsteam,andbenchmarked

    throughmonthlyreportingofenergyuse.

    Toincreasetransparencyofenergyandbuildingperformanceinformation,

    theDepartmentwillusemeteringdataforbenchmarkingpurposes.

    Benchmarkingisakeyenergyefficiencymanagementtool. Itallowsfacility

    managerstocompareindividualbuildingperformancetosimilarbuildings,

    andallowscomparisontothebuildingsperformanceinpreviousyears. DOE

    willbenchmarkallindividuallymeteredbuildingsinEnergyStarPortfolio

    ManagertoallowDOEdecisionmakerstoanalyzebuildingenergyuseona

    building,site,orportfolioleveltobetterinformcorporatebudgetdecisions.

    UnderDOEOrder430.2B,DOEsitesannuallysubmitdataonthestatusof

    theiractualandpotentialenergyefficiencyandrenewableenergyprojects.

    Currently,DOEhasover100projectsundercontractforacombined

    investmentofabout$500M(withabout$340MofthatunderESPCcontract).

    Anadditional35projectsareindevelopment(meaningtheyarepreparingto

    solicitbids). DOEwillcontinuetoidentifyanddevelopenergyefficiencyand

    renewableenergyprojects(toincludebuildingcommissioningand

    recommissioning)toreducetheenergycostandfootprintofthevarious

    sites. AsummaryofenergyprojectsunderwayisprovidedinAppendix4.

    Overthelongterm,theDepartmentwillreducefacilityenergyintensityby:

    Installingenergyimprovementsinexistingbuildings(equipment

    upgrades;improvingmaintenance,commissioningprocedures,and

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    28/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page24

    operatingprocedures,retrofittingwithcoolroofs7andENERGY

    STARmaterialsandapplianceswhereappropriate,andbuilding

    envelopeimprovements)

    Constructionofnewbuildingsthatarehighlyefficientandfollowthe

    GPofsustainability(seeGoal4)

    Disposingexcessrealpropertyinventory

    Reductionofprocessenergyloadswherepractical

    Utilizationofadvancedbuildingmeteringforrealtimecontroland

    display,andtoencourageenergyefficientpracticesamong

    employeesthroughawardsandincentives

    UtilizationofDOEfacilitiesforenergydemonstrationprojectsand

    emergingtechnologiesforcommercialuse

    Systematicconsiderationofenergyreductionasafactorinthe

    decisionprocessformaintenanceandrepair

    Rebenchmarkingindividuallymeteredbuildings(annually)tocompare

    buildingperformancetopeersandtopastyears. Buildingenergy

    performancebenchmarkswillbepublicallydisclosed

    Reverifying(periodically)thatgreenbuildingscontinuetomeet

    greenbuildingcertifications

    RecognizinghighestperformingbuildingswithSecretarialAwards.

    Reducingtheenergyintensityofexistingfacilitieswillcontinuetobeamajor

    componentofthesustainabilitystrategy. Purchasedelectricityaccountsfor

    approximately60%ofDOEsScope1and2GHGinventory.

    ExistingFacilities. Numerous

    opportunities

    exist

    to

    improve

    the

    energy

    efficiencyofexistingbuildings. Theseinclude:

    Installingmoreefficientequipmentorbetterequipmentcontrols

    Improvingmaintenance,commissioning,andoperatingprocedures)

    Retrofittingbuildingswithcoolroofs

    UsingENERGYSTARmaterialsandappliances

    Improvingthebuildingenvelope(insulation,windows,and

    weatherization)

    FacilityDeactivationandDecommissioning. DOEwillcontinuetodisposeof

    assetsnolongerneededforcurrentorfuturemission. Facilitiesidentifiedfor

    disposition,butnotremovedwilloperateatminimalenergylevelssoasto

    preventfurtherenvironmentaldegradation.

    7SeeSecretaryofEnergymemoofJune1,2010: InstallationofCoolRoofsonDepartmentofEnergy

    Buildings

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    29/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page25

    From2003through2009,DOEconductedD&Dproceduresonabout2.1M

    GSFperyear(averagingabout400buildings/year). Forplanningpurposes,it

    isassumedthatabout2MGSFperyearofbuildinginventorywillbe

    decommissionedanddisposedofeachyearfromFY2010throughFY2020.

    TheDepartmentusesaoneforonepolicy,whichstatesthatforevery

    squarefootofnewconstruction,onesquarefootofsimilarbuildingtype

    mustberemoved.8

    NewConstruction. DOEOrder430.2Brequiresallnewconstructionand

    majorrenovationsunder$5MtocomplywiththeGP,andbuildingsabove

    thatthresholdtoachieveLeadershipinEnergyandEnvironmentalDesign

    (LEED)Goldcertification,ifithadnotreachedcriticaldecision2(CD2)

    beforeOctober1,2008. BothLEEDGoldcriteriaandtheGPanalyzeand

    scoreenergyefficiency,waterefficiency,andenergysavingstrategies. Asof

    May2010,thereare87buildingsandstructuresscheduledforcompletionby

    FY

    2020

    (in

    development

    at

    CD

    2

    or

    above).

    These

    buildings

    will

    add

    in

    excessof6MGSFandconsumeover800,000MWHofelectricityandover

    400Mcubicfeetofnaturalgaseachyear.

    Asanticipatedconstructionofnewfacilitiesmayincreasefutureenergy

    consumption,theDepartmentisensuringfacilitiesaredesignedandbuiltto

    operateasefficientlyaspossiblewhileachievingmissiongoals. Increased

    energyconsumptionwillbeoffsetbyincreasedrenewableenergy

    generation,energyefficiency,andRECprocurement,asnecessary.

    v.DepartmentLeadforGoalThethreeUnderSecretariesareresponsibleformeetingthetargettoinclude

    theplanning,budgeting,development,implementationandoversight.9

    vi.PositionsAspreviouslydescribed,DOEplanstoestablishanSPO.

    DOEwillconductatrainingneedsassessmentofallDOEdesignatedenergy

    managersanddevelopastrategyforaddressingnotedshortfalls. DOEwill

    requiretheFacilityEnergyManagerofeveryDOEsitetoattainaCertified

    EnergyManagerqualification. TheEnergyManagerpositiononallsiteswith

    8HouseReport109086EnergyandWaterDevelopmentAppropriationsBill,2006.

    http://thomas.loc.gov/cgibin/cpquery/R?cp109:FLD010:@1(hr086)

    9ThethreeUnderSecretariesareresponsibleforeachoftheiroperations,theDOEOfficeofManagement

    (MA)isresponsibleforthetwoHeadquartersbuildings,theDOEOfficeofHealth,SafetyandSecurity

    (HSS)isresponsiblefortheNationalTrainingCenter,andeachAdministratorofaPowerMarketing

    Administrationisindividuallyresponsiblefortheirorganization.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    30/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page26

    greaterthan5millionsquarefeetofbuildingsshallbeafulltimeposition

    focusedonwater,energyandGHGmanagement.

    b.RenewableElectricityInstallation&Use

    AnumberofDOEsitesarelocatedinareaswithabundantrenewableenergy

    resources(toincludesolarinNewMexico,windinTexasandIdaho,and

    biomassinSouthCarolina). Evenbeforethecurrentgroupofstatutesand

    ExecutiveOrders,DOEledtheNationinthedevelopmentofrenewable

    energy.

    i.GoalDescriptionEPAct2005requiresfederalagenciestoensurethatnolessthan5%ofits

    electricenergycomesfromrenewablesourcesfrom20102012,andthatno

    lessthan7.5%befromrenewableelectricsourcesinFY2013andbeyond.

    EO

    13423

    requires

    that

    at

    least

    half

    of

    the

    required

    renewable

    energy

    come

    fromnew(post1999)renewableenergysources,andencourages

    departmentstoinstallrenewableenergygenerationonsiteforusebythe

    site.

    ii.CurrentStatusMostDOEsiteshaveinstalledandusesomeformofrenewablepower. The

    largerscalerenewableelectricityinstallationsarelocatedinColorado,

    includingalmost2MWfromphotovoltaic(PV)arraysandupto4MWfrom

    windturbines. DOEhassmallerprojectsinotherlocations,includingrooftop

    PVarraysinWashingtonDC,geothermalpowerinWyoming,anddish

    SterlingsolarpowersystemsinNewMexico. Additionallargescaleprojects

    beingdevelopedonDOEpropertyincludeamajorbiomasspoweredco

    generationplantinSouthCarolinaanda37MWPVsysteminNewYork.

    AtthebeginningofFY2010,DOEreceived0.16%ofitselectricalenergyfrom

    onsiterenewablesources. ByFY2011,DOEexpectstoaddanother0.5%of

    renewableelectricity,primarilyfromwindenergyattheNationalRenewable

    EnergyLaboratory(NREL). Anadditional4.4%ofonsiterenewableelectric

    power(primarilyfromthebiomasspoweredCHPplantattheSavannahRiver

    Site)isexpectedtobeonlinebytheendofFY2012,foratotalof5.1%of

    DOEs

    electricity

    consumption

    coming

    from

    renewable

    sources.

    iii.SpecialConsiderationsManypotentialalternativelyfinancedorPPAprojectsdonotmeetNPVor

    ROIcriteriabecauseofthelimitedcontractingperiodscurrentlyauthorized

    fortheseprojects. ExpandingthecontractedperiodforPPAscouldexpand

    commercialinterestindevelopingandfinancingrenewableenergyprojects.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    31/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page27

    DOEwillworktodeterminehowthisperiodcouldbeexpandedforfuture

    negotiation.

    LargebulkenergycontractshaveallowedDOEsitestoobtainhighly

    favorableenergyratesinmanyregionsofthecountry. Onapurelyeconomic

    basis,manyrenewableenergytechnologiesmaynotbeabletocompetewith

    thislowcostofenergy,howeverrenewableenergyhasmanybenefits.

    Movingforward,theDepartmentwilltakesocialandenvironmentalcosts

    intoconsiderationwhendeterminingthebestmixofenergysourcesand

    negotiatingfutureutilitycontracts.

    DOEownsandcontrolslargetractsoflandthathavebeenreclaimedafter

    industrialcleanup. Muchofthislandrequireslongtermmonitoringandis

    notcurrentlysuitableforunconstraineddevelopment. DOEwillexaminethe

    feasibilityofusingthislandforfutureREproduction. TheDepartmentis

    pursuing

    Enhanced

    Use

    Leasing

    (EUL)

    authority

    to

    improve

    opportunities

    to

    makethislandusefulwithoutinterferingwiththelongtermmonitoring

    effort.

    iv.ImplementationMethodsRenewableenergyassessmentreportsforalargenumberofDOEsiteswere

    completedinthe20072009timeframe. Asufficientnumberofprojects

    wereidentifiedtomeettheREgoalfromonsiteprojects,however,few

    projectswerefoundtohaveapositiveNPVorROIatthattime. DOEwill

    continuetoevaluatethemorepromisingprojectsfordevelopmentwhile

    researchingfavorablenewprojects.

    IntheneartermDOEwill:

    Conductsitesurveysandidentifynewprojects

    CollaboratewithotherFederalagenciestoleverageopportunitiesand

    bestpractices

    Developandconstructrenewableenergyprojectsasappropriate

    PurchasegreenpowertomeetstatutoryandEOgoalsasnecessary

    Workwithotheragenciestodeterminebestpracticesforalternative

    financingmechanisms.

    SiteassessmentsandenergyauditswillenableDOEtoidentifynew,more

    promisingprojects. Inthepast,manyrenewableenergyprojectscouldnot

    competeagainstthelowcostofgridsuppliedenergy. Factorsthatincrease

    thelocalcostofelectricity(suchasacarbontax,gridcongestion,ornew

    billingstructure)maysignificantlychangethefinancialviabilityofrenewable

    energyprojects. Assuch,additionalassessmentswillbeconductedeach

    yeartoinvestigatethetechnicalandeconomicfeasibilityofnewprojectsor

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    32/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page28

    toreevaluatethefinancialviabilityofanexistingproposalwherelocal

    factorsmayhavechanged.

    DOEfundsthedevelopmentofmanynewREtechnologies. TheDepartment

    willevaluateitssitestodeterminetheirpotentialtoperformlargescale

    demonstrationand/orinstallationofnewREandEEtechnologies

    Whilemostpreviouslargeprojectswerefundedusingalternativefinancing

    methods,otherpromisingprojectsmayneedacombinationofappropriated

    andalternativefundingtobeconsideredfordevelopment. Inaddition,DOE

    willevaluatetheuseofrenewableenergyPPAsinthewesternUnitedStates

    forperiodslongerthan10years(throughtheWesternAreaPower

    Administration).

    DuringtheperiodFY20122020,DOEwilldemonstrateleadershipby

    achieving

    the

    following

    goals:

    Produceatleast7.5%ofitselectricityfromonsitesources(eliminate

    theneedtobuygreenpower)

    Cofireallcoalfedboilerswithbiomasstothemaximumextent

    possible(whereaneconomicsourceofbiomassisavailable)

    ConductlargescaledemonstrationofpromisingREtechnologiesat

    DOEsites

    v.DepartmentLeadforGoalThethreeUnderSecretariesareresponsibleformeetingthetargettoinclude

    theplanning,budgeting,development,implementationandoversight.

    vi.PositionsAspreviouslydescribed,DOEplanstoestablishanSPO.

    c. Fleet

    DOEmaintainsadiversefleetofvehicles. Whilesomearepassenger

    vehicles,othersaremedium andheavydutytrucksorarespecialpurpose

    vehicles. Attheendof2009,theDOEfleetconsistedof14,279vehicles

    managedby96reportingorganizationsdistributedthroughouttheUnited

    States. Thisfleetincluded5,067E85capablevehicles,213compressed

    naturalgasvehicles,135hybrids,13liquidnaturalgas,andthreeliquid

    petroleumgasvehicles.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    33/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page29

    i.GoalDescriptionEISA2007andEO13423requirea2%peryearreductioninfleetpetroleum

    usethroughFY2015(fromaFY2005baseline). EO13514incorporatesthis

    requirementandextendsitto2020,foranoverallreductionof30%. EISA

    2007alsorequiresfederalagenciestoincreasetheuseofnonpetroleum

    fuelsby10%annually. EISA2007,EO13423andEO13514allprovide

    directionforfederalagenciestopurchaselowGHGemittingvehicles,

    includingalternativefuelvehicles.

    ii.CurrentStatusDOEcurrentlymeetsallannualrequirementsofthelawandthevariousEOs.

    DOEhasalreadymetthe2013milestoneforalternativefueluse.

    iii.SpecialConsiderationsThecommencementorcompletionofalargeenvironmentalmanagement

    activity

    (which

    frequently

    uses

    a

    significant

    number

    of

    heavy

    duty

    vehicles)

    maydriveDOEsfuelstatisticsupordownbyasignificantpercentage. Asa

    result,petroleumfuelusagenumberswillfluctuatealongatrendline.

    WhileDOEmetthepetroleumreductiongoalin2009,manyprojectswill

    startandstopbeforeFY2020. TodateDOEhasnotreducedfuelusage

    enoughtoensurethefluctuationremainsbelowtherequiredlimit,andthus

    willdetermineandundertakeadditionalmeasurestoensurecontinued

    compliance.

    DOEhasalargeproportionofmediumandheavydutyvehicles,almost

    threetimestheproportionofotherFederalagencies. Whilefewcost

    effectivefuelsavingsoptionscurrentlyexist,DOEwillconsidershiftingto

    biofuelswherepossible,andwillcloselyexaminepotentialsolutionsinthe

    researchanddevelopmentpipelineandmovetoadoptthemwhere

    appropriate.

    iv.ImplementationMethodsDOEistakinglarge,boldstepstoreachthevariousgoals:

    ReplacetheIdahoNationalLaboratory(INL)dieselbusfleet

    UseaGeographicInformationSystemoptimizationtooltoguide

    relocationoflightweightvehicles

    Purchasehybridelectricvehicles(HEV)

    RelocateE85capablevehicles

    Developinfrastructuretosupportelectricvehicles(EV)andplugin

    hybridelectricvehicles(PHEV)

    Increaseuseofbiodieselfordieselfueledvehicles

    Downsizetosmallervehicleswherefeasible

    Conductdrivertraining

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    34/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page30

    Eliminateunnecessaryvehiclesinthefleet

    TheDOEbusfleetatINLisamajorconsumerofpetroleumdieselfuel. DOE

    intendstoreplacethesebuseswithnewbusespoweredbycompressed

    naturalgas. Doingso,DOEwillgreatlyreduceitspetroleumuse,increaseits

    useofalternativefuels,andenticeemployeeswhocurrentlydrivetothesite

    totakethebus(reducingScope3GHGemissions). Thetimingandmethod

    toconductthisreplacementiscurrentlyunderevaluation.

    TheDepartmentofEnergyisfundingdevelopmentofafleetoptimization

    toolbyNREL. Thistoolwilloptimizethedeploymentofalternativefuel

    vehiclestomaximizetheiruseofalternativefuels;andtooptimizethefleet

    vehicleinventorytoensuremissionneedsaremetwiththeappropriatesize

    andnumberofvehicles. DOEintendstousethisprograminthe

    managementofitslightvehiclefleet.

    DOEhascommittedtoacquiringalargenumberofHEVs. Thesevehicles,

    withbetterfueleconomythanthevehiclestheyreplace,willreducethe

    Departmentspurchaseofgasoline. DOEwillreplace850gasolinevehicles

    withHEVsinthenearfuture.

    InparallelwiththepurchaseoftheseHEVs,DOEwillrelocateitsE85

    capablevehiclesintoregionsofthecountrywhereE85ismore

    commerciallyavailable. Whereneeded,DOEwillinstallfillingstationson

    siteorataconvenientlocationtosupporttherelocationofE85vehicles.

    TheseactionswillincreaseaccessofE85capablevehiclestoE85fuels,

    increasingtheDepartmentsuseofalternativefuels.

    DOErecognizesthatEVandPHEVwillbeavailableinthenearfuture. In

    preparationforthesevehicles,DOEwillestablishaprogramtoencourage

    theinstallationofelectricchargingstationsforsiteuse,andforuseby

    commuters. Wherepossible,thisprogramwouldbetiedtotheinstallation

    ofonsiterenewableenergygeneration. TheseactionswouldreduceDOEs

    purchaseofpetroleumfuelsandwouldprovideanincentiveforcommuting

    employeestopurchaseelectriccapablevehicles(EVorPHEV),reducing

    Scope3emissions.

    DOEalsowillconducttrainingofpotentialdriverstohelpthemdevelop

    skillsandbehaviorstomaximizethefueleconomyofthesevehicles. This

    trainingwillbeprovidedtobothfederalandsitecontractoremployees.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    35/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page31

    v.DepartmentLeadforGoalThethreeUnderSecretariesareresponsibleformeetingthetargetto

    includetheplanning,budgeting,development,implementationand

    oversight.

    vi.PositionsAspreviouslydescribed,DOEplanstoestablishanSPO.

    d. FugitiveEmissions

    i.GoalDescriptionDOEwillreduceGHGemissionsfromnonCO2sources,andwillsetspecific

    yearlyreductionmilestonesinthenearfuture.

    ii.CurrentStatusDOEs

    non

    CO2

    GHG

    emissions

    comprise

    an

    estimated

    14%

    of

    the

    DOE

    Scope

    1and2GHGinventory. Theseestimatesarebeingvalidatedwhileanew

    processisdevelopedtotrackfugitiveemissions. ThemajorityoftheseGHG

    emissionsarefromofSF6gasreleases,whereSF6iscommonlyusedasan

    electricinsulator(dielectricmedium)inhighvoltageelectricalequipment.

    Itsreleaseisattributedtothreecauses: maintenance,equipmentfailure,

    andgasseepage. Releaseestimatesarebasedonhistoricalpurchasing

    documentsandnotbydirectmonitoringforleakage. Assuch,these

    estimatesdonotdifferentiatebetweenthevariouscausesofleakageorthe

    fluctuatinginventoryofgasinthesubjectequipment.

    iii.SpecialConsiderationsOver95%oftheSF6emissionscomefromninesites,withover80%coming

    fromjustfoursites. DOEwillworktodeterminehowbesttoreduceSF6

    emissions. Reductioneffortswillbetargetedtothesespecificsites.

    iv.ImplementationPlanDOEwilladdressSF6emissionsthroughatwofoldapproach:

    ReduceSF6releasedduringmaintenanceactions

    Findanalternativedielectricmediumthatisecofriendlyandprovides

    comparableorsuperiorelectricalinsulationperformance

    Reducingmaintenanceemissionswillbeaccomplishedwithcaptureand

    storageequipment,developingprocedurestorecaptureandthenreuseSF6

    recoveredduringmaintenanceactions,developingtraining,anddeploying

    theSF6captureprogramatkeyDOEsites. Thenecessarycaptureequipment

    iscommerciallyavailable.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    36/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page32

    AFugitiveGasWorkingGroupwillbeestablishedtoshareinformationand

    monitoring/controltechnologyamongstthosesiteswithsuchgases. This

    groupwillalsobetaskedtolookforanenvironmentallyfriendlyreplacement

    material. Ifnosuchmaterialcanbefound,DOEwillconsiderproviding

    supportforthedevelopmentofanecofriendlyreplacementmaterial.

    v.DepartmentLeadforGoalThethreeUnderSecretaries,withassistancefromtheOfficeofProcurement

    AssistanceManagementandtheOfficeofHealth,SafetyandSecurity,are

    responsiblefortargetplanning,budgeting,development,implementationand

    oversight.

    vi.PositionsAspreviouslydescribed,DOEplanstoestablishanSPO.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    37/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page33

    Table6:Goal1PlanningTable10

    2. GOAL: Scope3GreenhouseGasReduction

    TherearemanycategoriesofScope3GHGemissions. ForthePlansubmittedin

    June2010onlythreecategoriesareconsidered: employeetravel,contracted

    wastedisposal,andtransmissionanddistributionlossesfrompurchased

    electricity. Whilereductionactionsforeachcategoryareseparate,they

    primarilyfocusonchanginghumandecisions: findwaystoperformlesstravel,

    10Fundingamountsprovidedarestrictlyestimatesandaresubjecttochange.

    SCOPE1&2GHGTARGETUnit

    FY10

    FY11

    FY12

    FY13

    FY14

    FY15

    FY16

    .

    FY20

    EnergyIntensityReduction

    Goals.

    BTU/SF

    reduced

    from

    FY03baseyear)%

    15%

    18%

    21%

    24%

    27%

    30%

    hold

    hold

    PlannedEnergyIntensity

    Reduction. (BTU/SFreduced

    fromFY03baseyear)

    % 18% 19% 21% 24% 27% 30% hold hold

    Meterbuildingandprocesses

    onmultibuildingsitesfor

    electricity(%ofenergyuseon

    eachsite)

    % 20% 75% 90% hold hold hold hold holdBuildings

    Meterbuildingsandprocesses

    onmultibuildingsitesfor

    naturalgas,steamandchill

    water(%ofresourceuseon

    eachsite)

    % 5% 10% 25% 50% 75% 90% hold hold

    RenewableElectricityGoals

    (Percentofelectricityfrom

    renewablesources)

    % 5% 5% 5% 7.5% hold hold hold hold

    Renewables

    PlannedRenewableElectricity

    Use (Percentofelectricityfrom

    renewablesources)

    % 5% 5% 5% 7.5% hold hold hold hold

    PetroleumUseReduction

    Targets (Percentreduction

    fromFY05baseyear)

    % 10% 12% 14% 16% 18% 20% 22% 30%

    PlannedPetroleumUse

    Reduction(Percentreduction

    fromFY05baseyear)

    % 15% 18% 21% 24% 27% 30% hold hold

    AlternativeFuelUseinFleet

    AFVTarget(Percentincrease

    fromFY05baseyear)

    % 61% 77% 95% 114% 136% 159% hold holdFleet

    PlannedAlternativeFuelUsein

    FleetAFV(Percentincreasefrom

    FY05baseyear)

    % 125% 142% 159% hold hold hold hold hold

    Scope1&2 ReductionTarget

    (reducedfromFY08baseyear)% 2% 2% 0% 4% 8% 12% 17% 28

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    38/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page34

    producelesswaste,anduselesselectricity. FutureScope3GHGreportingis

    expectedtorequireexpandingthereportedcategoriesofemissions,thus

    adjustingDOEsoverallreductiongoalaccordingly.

    i.GoalDescriptionAfterreviewingthepreliminaryDOEScope3GHGinventoryforFY2008and

    anticipatingtheimpactoftravelandrecyclinglikelytobeputinplace,DOEset

    Scope3GHGreductiongoalsasfollows:

    Federalemployeetravel: 12%

    Contractedwastedisposal(wastenotcurrentlyrecycledorreused):12%

    TransmissionandDistributionlossesfrompurchasedenergy: 16%

    Pendingtheinclusionofnewcategories,theoverallDOEScope3GHGreduction

    goalis13%. Asnewcategoriesareaddedinsubsequentyears,theoverallgoal

    will

    change.

    ii.DepartmentStatusDOEsScope3GHGemissionsforFY2008wereestimatedtobejustunder

    750,000mTCO2e. ThisestimateincludesthecategoriescomprisingScope3

    emissionsasprescribedandrequiredbytheWhiteHousesCouncilon

    EnvironmentalQuality(CEQ)andtheOfficeofManagementandBudget(OMB)

    for2010:

    Federalemployeebusinessairandgroundtravel

    Employeecommute

    Contractedsolidwastedisposal

    Contractedwastewaterdischarge

    Transmission&Distribution(T&D)lossesrelatedtopurchasedelectricity

    iii.SpecialConsiderationsDOEconsistsofabout15,000Federalemployees. However,contractorsmanage

    andoperateDOEsitesunderagovernmentowned,contractoroperated(GOCO)

    model. Theyconsistofabout70,000personnelwhoperformfunctionsatDOE

    sitesindirectsupportoftheDOEmission. DOEelectedtoincludetheseprime

    contractoractivitiesinitsScope3calculations. Primecontractorsnotassociated

    withsiteoperations,aswellasallsubcontractors,internsandvisitorsarenot

    includedinDOEsScope3calculations.

    iv.ImplementationMethodsAchievementofthereductiongoalsrequiresacombinationofpolicyand

    behaviorchange. Implementationmethodsforeachcategoryaredescribed

    below.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    39/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page35

    BusinessAirTravel

    Increasinguseofwebbasedmeetings

    Reducingairtravel,exceptwherenecessaryformissionaccomplishment

    DOEwillconductaninternalsurveytodeterminewhereadditional

    bandwidthandequipmentareneededtosupportanincreaseinwebbased

    meetings. Oncetherequiredequipmenthasbeenorderedandinstalled,

    DOEwillreassesstheneedforandcriteriausedtoapproveairtravel.

    Effortswillbemadetoreduceoreliminateshortrange(

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    40/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page36

    Introducingenvironmentallyfocusedproductpackagingrequirements

    Increasingreusabilityorrecyclabilityrequirementsinprocurementpractices

    ActionsinsupportofcontractedwastedisposalareaddressedunderGoal7

    and8ofthisPlan. Siteswillcontinuetoencourageemployeestorecycleand

    reusematerials.

    ContractedWasteWaterTreatment

    EncouragingTelecommuting

    DOEwillsurveyallsitestodeterminetheapplicabilityandimplementationof

    existingtelecommutingpolicy. UponcompletionofthissurveyDOEwill

    reviewand,ifneeded,reviseitsexistingtelecommutingpolicy.

    TransmissionandDistributionLosses

    Increasingonsitegenerationofelectricity

    Increasingpurchasesofgreenenergy

    Actionstoreducetheneedtopurchaseelectricityfromthegridinclude

    reductionofneed(energyefficiency)andincreaseoflocalsupply(local

    generation). TheseissuesareaddressedinGoal1.

    v.DepartmentLeadforGoalThethreeUnderSecretariesareresponsibleformeetingthetargettoinclude

    theplanning,budgeting,development,implementationandoversight.

    vi.PositionsAspreviouslydescribed,DOEplanstoestablishanSPO.Table7:Goal2PlanningTable

    11

    SCOPE3GHGTARGET Units FY10 FY11 FY12 FY13 FY14 . FY20

    OverallAgencyScope3

    ReductionTarget(reduced

    fromFY08baseyear)

    % 0% 1% 2% 3% 4% 13%

    SubTargetforFederal

    EmployeeTravel% 0% 1% 2% 3% 4% . 12%

    SubTargetforContracted

    WasteDisposal %

    0%

    1%

    2%

    4%

    6%

    .

    12%

    SubTargetforTransmission

    andDistributionLossesfrom

    PurchasedEnergy

    % 0% 0% 1% 3% 5% . 16%

    11Fundingamountsprovidedarestrictlyestimatesandaresubjecttochange.

  • 8/4/2019 US Department of Energy DOE: Sustainability Plan 2010

    41/92

    DepartmentofEnergy|2010

    StrategicSustainabilityPerformancePlan|Page37

    3. GOAL: ComprehensiveGreenhouseGasInventory

    ThedevelopmentofacomprehensiveGHGinventoryiscriticallydependentonthe

    accuracyandcompletenessoftheinputdata. DOEwillrefinecurrentdatacollection

    methodstoacquirethedataneededtoproduceacomplete,accurateand

    sustainableinventory.

    i.GoalDescriptionDOEisrequiredtoprovideacomprehensiveinventoryofScope1,2,and

    specifiedScope3emissionstotheCEQChairandOMBDirectorbyJanuary2011

    andannuallythereafter.

    ii.CurrentStatusDOEsitesreportfuelandutilitypurchasingdataintoaDOEdatabase(EMS4).

    This

    data

    is

    used

    to

    develop

    an

    inventory

    of

    GHG

    emissions

    from

    electric

    and

    carbonbasedfuels. NonCO2basedGHGemissionsaretrackedthroughadhoc

    datacallstodeterminethepurchasehistoryandquantityofknownGHG

    emittingsubstances. Thehistoricalcontextofmanypastpurchasesremains

    unknown;henceGHGemissionreportsfromthesesubstancesareonly

    estimates.

    Scope3GHGemissionsfromFederalemployeeairtravelwerebasedondata

    accessiblethroughGSA. Contractorairtraveldatawascollectedviaadatacall.

    DatarequestedbytheCEQprovidedScope3GHGTargetingTool(gallonsoffuel

    forrentalcars,milestravelledforpersonallyownedvehicles,bus,rail,subway)

    wasnotavailable. Instead,DOEderivedthisinformationfromtravelclaim

    informationretainedforFY2008. DatarequestedbytheScope3GHGTargeting


Recommended