WELCOME TO THE PRESENTATION ON STEAM TURBINE PROTECTIONS AND GOVERNING SYSTEMS AT ESCI, HYDERABAD BY BHEL – PS SR, CHENNAI 8-9 Dec, 2004
Transcript
Page 1: Utility Turbines

WELCOME TO THE PRESENTATION ON

STEAM TURBINE PROTECTIONS AND

GOVERNING SYSTEMS

AT

ESCI, HYDERABADBY

BHEL – PS SR, CHENNAI8-9 Dec, 2004

Page 2: Utility Turbines

CONTROLS OF LARGE UTILITY TURBINES

Presentation By

Srinivasan Selvaraj

Page 3: Utility Turbines

Main Control Systems Electro-Hydraulic Governing System (EH

TC) Turbine Stress Evaluator (TSE) LP Bypass Control System (LPBP) Gland Steam Control System (GSC) Protection System Turbovisory System (TSI) Automatic Turbine Tester (ATT)

Page 4: Utility Turbines

Electro-Hydraulic Governing System (EHTC)

Page 5: Utility Turbines

EHTC: Advantages Safe Operation of Turbine in

conjunction with Turbine Stress Evaluator (TSC)

Excellent Operation Reliability and Dependability

Low transient and steady state speed deviations

Page 6: Utility Turbines

EHTC: Advantages

Dependable control during load rejection

Reliable Operation in case of Isolated Grid

Page 7: Utility Turbines

Critical Measuring Devices Speed Probes (3 Nos.) and

associated circuit elements Load Transducers (3 Nos.) Electro-hydraulic Converter housed

in Governing Rack (1 No.) Position Feedback Transmitter of

EHC

Page 8: Utility Turbines

Control Loops

Speed Control Load Control Pressure Control

Page 9: Utility Turbines

Speed Control: Main Functions PD Controller Start Up & Shut Down of Turbine Synchronizing with grid Providing Min. Load Operation of Turbine over entire

range of Load in case of Load Controller Failure

Page 10: Utility Turbines

Load Control: Main Functions

PI Controller Provision of load reference

limiter Frequency influence option

Page 11: Utility Turbines

Pressure Control:Main Functions

PI Controller Initial pressure control Limit pressure control

Page 12: Utility Turbines

LOADCONT. PI

Governing Scheme for KWU Turbines

HYD

ELMIN

PRESSURECONT. PI

MAX

SPEEDCONT. PD

_

+

MINPrsu

m

++

+

_

+

PrtdPr

_

+NrtdNr

Nact

Pact

Pmax

Fact

Fref

_

+

_

+pREF

pACT

0

P

R

S

LIMIT PRES.

INIT. PRES.

MIN

Page 13: Utility Turbines

MIN

HYD

HYD

HYD

EL

SPEEDERGEAR

STARTING DEVICE

MIN

FROM ELECCONTROLLER

TO CONTROLVALVES

Governing Scheme for KWU Turbines

Page 14: Utility Turbines

Additional Functions

Tracking device option Load shedding relay Auto Synchronizer Isolated grid operation

Page 15: Utility Turbines

Tracking Device Functions

The starting device keeps varying automatically with variation in the position of EHC. In case the EHC fails the starting device will restrict the raise in the load.

Page 16: Utility Turbines

Load Shedding Relay Functions

During sudden load throw–off conditions, there will tendency for the speed to raise rapidly. To avoid such conditions the LSR gives a close command for closure of the control valves for a brief moment. The magnitude of load throw,time duration of closure of control valves are settable in the LSR.

Page 17: Utility Turbines

Auto synchronizer Functions

The auto synchronizer accepts Gen and Grid Potential transformer signals. To match the frequency and voltage of the Generator, the auto. Sync. Unit gives Speed raise/lower command to EHTC and voltage raise/lower command to AVR.After parameter matching the auto sync. Unit generates a command for Synchronizing the unit

Page 18: Utility Turbines

Auto synchronizer Functions

After parameter matching the auto sync. Unit generates a command for Synchronizing the unit

Page 19: Utility Turbines

Turbine Stress Evaluator (TSE)

Page 20: Utility Turbines

Turbine Stress Evaluator Compares thermal stress in the

monitored components with the permissible limits and generates margins.The temperature margin is fed to the set point controller – speed and load.

Derives start up criteria for ATRS

Page 21: Utility Turbines

TSE: Components Monitored Emergency stop valve. HP control valve. HP casing. HP shaft. IP shaft.

Page 22: Utility Turbines

TSE: Measuring Points Surface and mid wall temperatures of

ESV (Ti & Tm) Surface and mid wall temperatures of

HPCV Surface and mid wall temperatures of

HP casing. Derived value for HP and IP shaft

temperatures from specified locations in respective casings.

Page 23: Utility Turbines

TSE: Operating Modes Three modes viz., fast, normal,

slow available. The increased fatigue rate

associated with fast mode can be compensated by more slow mode operation.

Page 24: Utility Turbines

TSE: Margins For any component, the difference Ti –Tm

represents the actual thermal stresses. Depending on the value of Tm and

operating mode the permissible value of thermal stress is determined.

From the difference between the permissible stress and prevailing actual stress the margin is derived.

Page 25: Utility Turbines

TSE: Margins The margins of different

components are provided in the Bar graph form in the TSE monitor.

The reference variable derived from the minimum margin acts directly on the turbine control system.

Page 26: Utility Turbines
Page 27: Utility Turbines
Page 28: Utility Turbines
Page 29: Utility Turbines
Page 30: Utility Turbines

LP Bypass Control System (LPBP)

Page 31: Utility Turbines

LPBP system: Main FeaturesEnables alternative path for dumping steam from RH outlet to condenser bypassing IP and LP turbine.Maintains RH pressure from a criteria representing the HP turbine flow.Works in conjunction with HP bypass systems and when necessitated by the system.

Page 32: Utility Turbines

LPBP system: Main FeaturesProvides fixed and variable set point.Protects the condenser by water injection.Hydraulically protects the system when the water injection press. is v low or condenser press. is v high

Page 33: Utility Turbines

LPBP system: Pressure controlProcess variable for control loop is acquired from Press. Transmitter in RH line.Two set values viz. Fixed set point and variable set points are formed and maximum value is used as reference.

Page 34: Utility Turbines

LPBP system: Pressure controlFixed set point is varied with push button in the control desk.Variable set point is derived from I stage pressure of HP turbine which is an indicative parameter of steam flow.Manual operation of valves is possible with push buttons in the control desk.

Page 35: Utility Turbines

LPBP Scheme for KWU turbines

PTf(x)

Fixedsetpoint

MAX

PT

PICont.

Valve Lift PID

RH press

I stg. press

+

To EHC

From EHC LVDT

+

-

-

Page 36: Utility Turbines

Gland Steam Control System (GSC)

Page 37: Utility Turbines

Gland Steam Pressure Control Maintains the Gland steam header

pressure at required value. Provided with two control valves

viz. seal steam control valve and gland steam control valve.

Process variable is the header pressure from a transmitter.

Page 38: Utility Turbines

Gland Steam Pressure Control The electro-hydraulic actuator

have inbuilt pump and it is powered by separate power supply.

In the event of pump failure,the valve remains stay put.

Page 39: Utility Turbines

GSPC Scheme for KWU turbines

PT

PICont.

GS headerpress

+

-

Setpoint. f(x)

EHC

f(x)EHC

Seal steam valve

Leak steam valve

Cont.output 100

CommandTo

Valve

100

0

Seal steam valveLeak steam valve

Page 40: Utility Turbines

Protection Systems

Page 41: Utility Turbines

Protection Systems

Electrical Protection Systems

Hydraulic Protection Systems

Page 42: Utility Turbines

Electrical Protection Systems Emergency PB (UCB) Lub Oil Pressure Very Low (2 out of

3) Fire Protection Trip Turbine Trip from ATRS Axial Shift Very High (2 out of 3) Over-speed Trip MFT Relay Acted from Boiler (2 out of

3)

Page 43: Utility Turbines

Electrical Protection Systems

Generator Protection Trip Vacuum Low Trip HP Exhaust Temperature Very High(2 out

of 3) Generator Cold Gas Temperature Very High Exciter Hot Air Temperature Very High Liquid Level in Generator Bushing Very

High (2 out of 3)

Page 44: Utility Turbines

Hydraulic Protection Systems

Over-speed Trip 1 & 2 Vacuum Low Trip Axial Shift Hand Trip Lever 1 & 2

Page 45: Utility Turbines

Features of Protection Systems Cyclic Test done periodically for each

Trip input Fault at input level will be annunciated Testing can be done online 2 out of 3 logic ensures reliability and

avoid spurious trippings 2 separate Processor Units realize the

Protection Logic with dedicated IOs.

Page 46: Utility Turbines

Features of Protection Systems Data of both processors matched

through Serial Communication and discrepancy annunciated

2 separate Solenoids provided in Hydraulic System for redundancy

First cause of trip will be annunciated

Online Testing of Final Tripping elements through ATT

Page 47: Utility Turbines

Resetting of Protection

Turbine Trip Solenoid stays in energised condition until the following conditions are fulfilled. Command from individual Trip ceases Both ESVs Closed Trip Oil Pressure less than 2 kg/sq.cm

Page 48: Utility Turbines

Turbovisory System (TSI)

Page 49: Utility Turbines

Absolute bearing vibration Absolute shaft vibration Axial shift Relative expansion – HP Relative expansion – IP Relative expansion – LP Overall expansion

Turbovisory Instruments

Page 50: Utility Turbines

Automatic Turbine Tester (ATT)

Page 51: Utility Turbines

Individual testing of each turbine protective devices.

Pretest ensures substitute devices. Monitoring of program steps for

execution within a certain time. Interruption if trip is initiated. Automatic reset of program after a

fault.

ATT : Features

Page 52: Utility Turbines

Sub group – Safety Devices. Sub group – HP/IP valves.

Automatic Turbine Tester

Page 53: Utility Turbines

Remote trip device 1 & 2. Over speed trip device 1 & 2. Low vacuum trip device. Thrust bearing trip.

ATT: Safety devices

Page 54: Utility Turbines

HP stop & control valve 1 HP stop & control valve 2 IP stop & control valve 1 IP stop & control valve 2

ATT: HP/IP Valves

Page 55: Utility Turbines

Release condition for start All protective device in operating

condition.

1st step command Checking of Provision of control fluid

for enabling test

ATT: LOGICS for safety devices

Page 56: Utility Turbines

Release condition for 2nd step Pressure before changeover valve >

5 kg/sq cm.

2nd step command Takes care of over speed trip-1

during test.

ATT: LOGICS for safety devices

Page 57: Utility Turbines

Release condition for 3rd step Pressure before changeover valve < 2

kg/sq cm. Pressure between sol. valve >5 kg/sq

cm.

3rd step command Takes care of over speed trip-2 during

test.

ATT: LOGICS for safety devices

Page 58: Utility Turbines

Release condition for 4th step Pressure between sol. valve <2

kg/sq cm. 4th step command Provision of control fluid.

ATT: LOGICS for safety devices

Page 59: Utility Turbines

Release condition for 5th step Pressure before changeover valve

>5 kg/sq cm. 5th step command Changeover valve to test position.

ATT: LOGICS for safety devices

Page 60: Utility Turbines

Release condition for 6th step Trip oil Pressure >5 kg/sq cm. Changeover valve test position. Aux startup fluid < 2 kg/sq cm. 6th step command Testing of remote trip device 1 & 2.

ATT: LOGICS for safety devices

Page 61: Utility Turbines

7th step command Testing of over speed trip device 1

& 2. 8th step command Testing of low vacuum trip device9th step command Testing of thrust bearing trip device

ATT: LOGICS for safety devices

Page 62: Utility Turbines

Start conditions All stop valves 100 % position Load controller in action Load < 66.6 % Trip oil pressure > 2 kg

ATT: LOGICS for valves

Page 63: Utility Turbines

Step I command Control valves - HP & IP Step II command Stop valves – HP & IP

ATT: LOGICS for valves

Page 64: Utility Turbines

Automatic Turbine Run-up System

(ATRS)

Page 65: Utility Turbines

Automatic Turbine Run-up System (ATRS) Acquisition, analysis and collation of

various parameters during Startup Sequential Control of Drives Unit Synchronization and Minimum

Load Operation Organised and hierarchically arranged

as Sub Group Control (SGC), Sub-loop Control (SLC), and Control Interface

Page 66: Utility Turbines

ATRS: Functional Group

S L C (Tu rn in g G e a r)

S L C (A O P 1)

S L C (A O P 2)

S L C (E O P )

S L C (JO P )

S G C (O il)

S L C (C E P )

S L C (V a c . P u m p)

S L C (V a c . B rk r)

S G C (C o n d & E va c)

S L C (D ra in s )

W a rm U p C o n tro lle r

S ta rtin g D e v ice

S e t P o in t D e v ice(S p ee d & L oa d)

A u to syn ch ro n iser

S G C (T u rb in e)

A T R S

Page 67: Utility Turbines

THANK YOU !