+ All Categories
Home > Documents > VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for...

VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for...

Date post: 30-Apr-2020
Category:
Upload: others
View: 26 times
Download: 0 times
Share this document with a friend
11
76 VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your VRV for best seasonal efficiency & comfort VRV configurator Software for simplified commissioning, configuration and customisation Night quiet mode Full inverter compressors Low noise function Sine wave DC inverter DC fan motor E-pass heat exchanger I demand function Manual demand function For detailed explanation of these functions refer to vrv iv technologies tab Air curtain Biddle Air curtain for VRV (CYV) Indoor units VRV type indoor units Ventilation Heat Reclaim ventilation (VAM/VKM) AHU connection kit Control systems 22 unique patented concept 76
Transcript
Page 1: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

76

VRV IV i-series heat pumpfor indoor installation

VRV IV standards:

Variable refrigerant temperatureCustomize your VRV for best seasonal efficiency & comfort

VRV configuratorSoftware for simplified commissioning, configuration and customisation

› Night quiet mode

› Full inverter compressors

› Low noise function

› Sine wave DC inverter

› DC fan motor

› E-pass heat exchanger

› I demand function

› Manual demand function

For detailed explanation of these functions refer to vrv iv technologies tab

Air curtainBiddle Air curtain for VRV (CYV)

Indoor unitsVRV type indoor units

VentilationHeat Reclaim ventilation (VAM/VKM)

AHU connection kit

Control systems

22

unique patentedconcept

76

Page 2: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

77

Invisible › Consider a wider range of properties because outdoor installation is not a factor

› Open for business sooner because getting building permits is simplified

Quiet › Highly suited to densely populated areas such as city centres thanks to their low operating sound

<

› Seamless integration into the surroundings as only the grille is visible

› No need for a roof installation or back alley installation

› Dedicated modes reduce sound further to comply with inner-city noise regulations

Lightweight parts can be installed by two people

Heat exchanger sound not louder

than a normal conversation

Compressor sound not louder

than a refrigerator

Out

door

Uni

t Pro

duct

Ran

ge

77

Page 3: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

78

Unrivalled flexibility thanks to the fact that the outdoor unit is split into two parts

12

Heat exchanger unit

Compressor unit

Max. 30 mMax. 70 m

VRV Indoor units

1. The heat exchanger can be installed in a false ceiling space.

2. The compressor is compact and easy to hide, this element can be installed at floor level, in a back office, storage room, technical area or in a kitchen.

1

2

Unique split outdoor unit for indoor installation

Compact and easy to hide, the compressor can be installed at floor level, in a back office, storage room, technical area or in a kitchen, while the

heat exchanger can be installed in a false ceiling space. This means that the air conditioning system is completely invisible and does not take up expensive commercial floor space.

This means that the air conditioning system is completely invisible and does not take up expensive commercial floor space.

78

Page 4: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

79

Invisible air suction and air discharge

Out

door

Uni

t Pro

duct

Ran

ge

79

Page 5: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

80

The problem solver for many installation issues

High flexibilty

The other way around: install the modules where if fits your customer, not where it is the best fit for the outdoor unit

If there is no flat roof or backgarden available for installation of the outdoor unit, VRV IV i-series offers the solution.

The suction and exhaust can be installed at the façade or at the rear of the building as the inverter fans allows ESP to be adjusted to the length of the ductwork.

The compressor module can be installed up to 30 m from the heat exchanger unit in a storage room, ....

Example 1

Flexible installation thanks to inverter fans

80

Page 6: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

81

SHOP

=

SHOP

Shorter pipe runs to the indoor units reduces installation costs compared to rooftop or back alley installation

Back alley or rooftop needs very long piping lengths › Long installation time › Additional cost › Capacity loss

VRV IV i-series can be installed close to the indoor units › Quicker installation › Lower cost › No capacity loss

No need for bulky and expensive sound countermeasures

To comply with city regulation countermeasures are needed for standard units › Expensive sound cages might be needed to reduce sound (standard outdoor unit sound = 50~60 dBA)

› Inside installation using expensive floor space

With VRV IV i-series you easily comply with city regulation without additional measures › Operation sound 47 dBA (flexible to install in corridor, shop area, …) or lower with attenuator

› No floor space is used as units can be installed in false ceiling, against the wall, …

Example 2

Example 3

short distance

Other VRF Other VRFVRV IV i-series VRV IV i-seriestechnicalaera

stock

stock

soundcage

kitchen

kitchen

More floor spaceReduced floor space Expensive counter measures No additional measures needed

Out

door

Uni

t Pro

duct

Ran

ge

81

Page 7: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

82

Patented V-shape heat exchanger for best surface to volume ratio

Patented perforated

and insulated partition plate

Reduces conductivity and

prevents cold bridges

Standard delivered filter

› with the unit to prevent dirt from entering the heat exchanger

Only 400mm high Fits easily in any false ceiling

8patents

Super efficient centrifugal fans

› Over 50% efficiency increase compared to sirocco fan › Patented backward- curved blade

technology › More pressure increase

Optimised air flow and temperature distribution

› Best performance for defrost (tested in high humidity down to -20°C).

82

Page 8: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

83

Compressor unit with rotating switchbox Flexible and easy to install

Only

77 kg

No drain connection needed › Thanks to natural evaporation › Minimized cold surface to reduce

dew formation › Fast and easy installation

Rotating switchbox

› For easy access to all compressor parts

Non welded bottom casing › Avoids any corrosion risk

Flexibility by back and top refrigerant connection possibility

Small footprint › Maximizes useable floor space (600 x 550 mm) › Can easily be mounted in a storage room, back office, …

Tube-in-tube subcool heat exchanger › This patented heat

exchanger increases the capacity of the system by ensuring optimal state of refrigerant in the heat exchanger module. This in turn increases overall efficiency.

Out

door

Uni

t Pro

duct

Ran

ge

83

Page 9: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

84

SB.RKXYQ5T

Outdoor system SB.RKXYQ 5T 8TSystem Compressor unit RKXYQ5T RKXYQ8T

Heat exchanger unit RDXYQ5T RDXYQ8TCapacity range HP 5 8Cooling capacity Nom. 35°CDB kW 14.0 22.4Heating capacity Nom. 6°CWB kW 14.0 22.4

Max. 6°CWB kW 16.0 -Power input - 50Hz Cooling Nom. 35°CDB kW 4.38 -

Heating Nom. 6°CWB kW 3.68 -Max. 6°CWB kW 4.71 -

EER at nom. capacity 35°CDB kW/kW 3.20 -COP at nom. capacity 6°CWB kW/kW 3.80 -

at max. capacity 6°CWB kW/kW 3.40 -Maximum number of connectable indoor units 10 (1) (1)Indoor index connection

Min. 62.5 100Nom. - -Max. 162.5 260

Fan External static pressure

Max. Pa 150 150Nom. Pa 60 -

Operation range Cooling Min.~Max. °CDB -5~46 -5~46Heating Min.~Max. °CWB -20~15.5 -20~15.5Temperature around casing

Min. °CDB 5 5Max. °CDB 35 35

Piping connections Between Compressor module (CM) and heat exchanger module (HM)

Liquid OD mm 12.7 12.7Gas OD mm

19.1 22.2

Between Compressor module (CM) and indoor units (IU)

Liquid OD mm 9.5 9.52

Gas OD mm 15.9 19.1

Total piping length System Actual m 140 300 (1) Actual number of units depends on the indoor unit type (VRV DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤ 130%).

Outdoor unit modulecompressor module heat exchanger module

RKXYQ5T RKXYQ8T RDXYQ5T RDXYQ8TDimensions Unit Height/Width/Depth mm 701/600/554 701/760/554 397/1,456/1,044 397/1,456/1,044Weight Unit kg 77 100 97 107Fan Type - - Centrifugal Centrifugal

Air flow rate Cooling Nom. m³/min - - 55 -Discharge direction - - Discharge duct Discharge duct

Sound power level Cooling Nom. dBA - - - -Sound pressure level Cooling Nom. dBA 47 56 47 -Refrigerant Type R-410A R-410A R-410A R-410A

Charge kg 2 4 - -TCO₂eq 4.2 8.4 - -

GWP 2,087.5 2,087.5 - -Power supply Phase/Frequency/Voltage Hz/V 3N~/50/380-415 3N~/50/380-415 1N~/50/220-240 1N~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 16 - 10 -

VRV IV heat pump for indoor installation

The invisible VRV

› Unique VRV heat pump for indoor installation

› Unrivalled flexibility because the unit is split up into two elements: the heat exchanger and the compressor

Heat exchanger unit

VRV Indoor units

Compressor unit

Max. 70 m

Max. 30 m

› Highly suited to densely populated areas thanks to the low operation sound and seamless integration into surrounding architecture as only the grille is visible

SB.RKXYQ-T

› Incorporates VRV IV standards & technologies: Variable Refrigerant Temperature, VRV configurator and full inverter compressors

› Lightweight units (max. 97kg) can be installed by two people › Unique V-shape heat exchanger results in compact dimensions (h/e unit only 400mm high) allowing false ceiling installation, while ensuring top efficiency

› Super efficient centrifugal fans (over 50% efficiency increase compared to sirocco fan)

› Small footprint compressor unit (600 x 550 mm) maximizing useable floor space

› Contains all standard VRV features

8HP launch 2nd half 2016

*Note: blue cells contain preliminary data

84

Page 10: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

85

Detailed technical drawings

RDXYQ-T

RKXYQ-T

9

8

7

6

5

4

3

2

1

No.

VP25

Part name Remark

A

705

Drain outlet

Liquid pipe connection portGas pipe connection port

Wiring intake (high voltage wiring)Wiring intake (low voltage wiring)

Hook

View A

149

239

45

255

1498

1456

1044

25

117

102

659

716

Ø 12.7 brazing connectionØ 19.1 brazing connection

Service door

123

4

5

6

7

8

9 (4x)

62

63

27

397

67 1196

Air suction sideAir discharge side

Suspension position

99

Susp

ensi

on p

ositi

on

Power supply connectionTransmission wiring connection

26

298

RDXYQ5T7V1B

2D098826

8

7

6

5

4

3

2

1

No. Part name Remark

426

Liquid pipe connection portGas pipe connection portLiquid pipe connection portGas pipe connection port

Handle

Wiring intake (high voltage wiring)Wiring intake (low voltage wiring)

55

59

85

88 120

337

365

54

57

15516

1

2

3

4

5

6

7

8

Ø 9.5 brazing connectionØ 15.9 brazing connection

Ø 12.7 brazing connectionØ 19.1 brazing connection

Knockout hole.

554

600

701

A

4x O17

Foundation bolt hole

Pitch of foundation bolt holes

Pitch of foundation bolt holes

View A

101

57

118

Power supply connectionTransmission wiring connection

Pipe routing hole

Heat exchanger unit

Indoor unit

RKXYQ5T7Y1B

3D098827

9

8

7

6

5

4

3

2

1

No.

VP25

Part name Remark

A

705

Drain outlet

Liquid pipe connection portGas pipe connection port

Wiring intake (high voltage wiring)Wiring intake (low voltage wiring)

Hook

View A

149

239

45

255

1498

1456

1044

25

117

102

659

716

Ø 12.7 brazing connectionØ 19.1 brazing connection

Service door

123

4

5

6

7

8

9 (4x)

62

63

27

397

67 1196

Air suction sideAir discharge side

Suspension position

99

Susp

ensi

on p

ositi

on

Power supply connectionTransmission wiring connection

26

298

RDXYQ5T7V1B

2D098826

Out

door

Uni

t Pro

duct

Ran

ge

85

Page 11: VRV IV i-series heat pump. Daikin/1. VRV/2. Outdoor Units/2... · VRV IV i-series heat pump for indoor installation VRV IV standards: Variable refrigerant temperature Customize your

86

Detailed technical drawings

RDXYQ-T

RKXYQ-T

10 or more 10 or more

10 o

r mor

e50

0 o

r mor

e

Top view

Front view

10 o

r mor

e

RKXYQ5T7Y1B

3D098835

Air suction side

Air discharge side

10 o

r mor

e

50 or more

100

or m

ore

500 or more

100

or m

ore

RDXYQ5T7V1B

3D098834

86


Recommended