Page 1/5
VT2-L • Rev. 2/6/20202233 rue de l’Aviation, Dorval, QC H9P 2X6
514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.standardpro.com
VT2-L2' LED VAPOUR TIGHTFeature rich contractor selectA luminaire ideal for a variety of industrial, commercial and residential applications. Installed either indoors or outside. Intended for applications where moisture and/or dust may be present. Ideal for garages and stairwell applications.
• Applications1 − Industrial facilities − Stairwells − Parking garages − Exterior retail areas − Transportation − Pedestrian tunnels
• Construction
Housing − Lightweight, flexible, durable and sealed polycarbonate construction
− Integral gasket forms uniform, long-life seal around the entire enclosure
− Reinforced plastic lens latch clips
− Sealed strain relief/cable gland kit included
− Power connection is easily accomplished through pre-drilled hole at one end of the housing that comes populated with a wet location watertight gland
LensThe UV stabilized polycarbonate lens with LED diffusing pigment is impervious to rust or rot and is unaffected by extreme temperatures.
• LINKThis unit can be used as an emergency backup unit powered by battery.
Please view the LINK brochure for more details on this technology.
• Specifications − Easy to clean and service − LED technology for long term energy savings
Driver − 120 V, 120 V-277 V and 347 V − 0-10 V dimming driver standard (down to 1%)
Ambient Temperature
-40°C to +40°C standard LINK : -40°C to +35°C
MountingStainless steel mounting hardware for wall, ceiling or suspended mounting.
• Compliances − Suitable for damp & wet locations − IP65 − 1 500 PSI: High pressure hose down test (1.3 gallon per minute for 3 minutes at 1.5-2.0' from the unit ) to maintain the integrity of the fixture. No water ingress is allowed
− Meets requirements of ICES-005 for class A products
− cETL − cULus2
FEATURES AND SPECIFICATIONS
quickship
linkcompatible
LED�xture
wet location
65
IP
005ICES
OVERVIEWLight source LED
Watts (W) 20 - 42
Lumen output (lm) 2 339 - 4 997
Efficiency (lm/W) 107 - 125
Color temperature (K) 3 500, 4 000, 5 000
CRI 80+
Weight (lbs) 4.35
1 Not recommended for car wash applications2 Certified for quick ship product only
Project: Type:
Date:Catalogue #:Drawn by :
Page 2/5
VT2-L • Rev. 2/6/20202233 rue de l’Aviation, Dorval, QC H9P 2X6
514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.standardpro.com
Data is based upon tests performed in a controlled environment. Actual performance can vary depending on operating conditions. All products are subject to change or may be discontinued any time without notice.
VT2-L
TECHNICAL SPECIFICATION TABLE
VT2 L
Series Lamp type Lumen package(lm)
Volts(V)
Color temp.(K)
Options
VT2 L - LED S1 S2
2 4004 600
W -A -H -
120-277120347
35K -40K -50K -
3 5004 0005 000
AC -L6 -L10 -SS - OS¹ -DL2 -DIM1-DIM23 -KV -TP4 -RMB -05-RMB-075 -
RMP-05 -RMP-075 -PVPM-05 -PVPM-075 -PVM -EH -CH -EL5 -
Aviation cable 6' cable length10' cable lengthStainless steel latchesOccupancy sensorAC and Emergency backup (from 0°C - 25°C) 120 V, 120-277 V0-10 V internal dimming wires ready to connectLine voltage dimming driver 120 V10k V Surge protectorVandal resistant screwsFor rigid mono point on a bracket with 3/4" (1/2 npt)For rigid mono point on bracket with 1" (3/4 npt) center hole drilled on bracketRigid mono point with 3/4" (1/2 npt) center hole drilled in luminaireRigid mono point with 1" (3/4 npt) center hole drilled in luminairePivot mount bracket with 3/4" (1/2 npt) drilled on bracketPivot mount bracket with 1" (3/4 npt) drilled on bracketPivot mount brackets (surface mount)End hole 7/8"Center hole 7/8"LINK
1 To see available options, please consult the occupancy sensors section. 2 DL option is not compatible with OS (internal). 3 DIM2 option is not compatible with OS (internal).4 1 tamper proof bit provided with order. For additional tamper proof bits, see accessories.5 The LINK Emergency Power conversion module is not compatible with the following options: DL, EH, OS (external).
ORDERING GUIDE
Lumenpackage
Watts
(W)
Volts
(V)
3 500 K 4 000 K 5 000 K CRI LifeL70(hrs)
Tested hours LM-80 (hrs)
Powerfactor
THD
(%)Lumen
(lm)Efficiency
(lm/W)Lumen
(lm)Efficiency
(lm/W)Lumen
(lm)Efficiency
(lm/W)
S1 20 120-277 2 339 117 2 429 121 2 507 125 80+ 180 500 10 000 0.99 7
S2 42 347 4 485 107 4 657 111 4 997 119 80+ 180 500 10 000 0.99 7
QUICK SHIP AND TECHNICAL SPECIFICATION TABLE 1
Part number
Watts
(W)
Volts
(VAC)
Color temp. (K)2
Lumen output (lm)3
Efficiency
(lm/W)
CRI Life L70
(hrs)4
Tested hoursLM-80(hrs)4
Dimming
(V)
Power factor
THD
(%)
VT2-LS1-W/40K 20 120-277 4 000 2 400 120 80+ 180 500 10 000 0-10 0.99 7
1 QUICK SHIP: Product availability is subject to change without notice. Please contact your Stanpro customer service representative to confirm inventory levels at time of order. 2 Typical color temperature range: +/- 5 %. 3 Lumen values are derived from photometric testing. Initial lumens range: +/- 10 %. 4 Life hours are derived from IESNA LM-80-08 testing report and projected per IESNA TM-21-11 extrapolations.
LINK TECHNICAL SPECIFICATION TABLELumen
packageLINK Watts (W)
3 500 K 4 000 K 5 000 KLINK
lumen output (lm)LINK
lumen output (lm)LINK
lumen output (lm)
S111
1 342 1 393 1 438S2 1 342 1 393 1 438
ACCESSORIES (order separately)
Part number
Type
HAR06-TPBIT-UDR Tamper proof 2" Steel Power Bit
Page 3/5
VT2-L • Rev. 2/6/20202233 rue de l’Aviation, Dorval, QC H9P 2X6
514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.standardpro.com
Data is based upon tests performed in a controlled environment. Actual performance can vary depending on operating conditions. All products are subject to change or may be discontinued any time without notice.
OCCUPANCY SENSORS
ON-OFF SENSORS
Detection - On at (Detection Area) % during (Hold Time) min. Off
Part number Position Volts(V)
Technology Height(ft)
Detection Area (%)
Hold time(min)
Daylight min level (lux)
Remote1 Location2
(°C)
OSE-PO-0301 External 120-347 PIR 20-40 100 20 NA Dry, -10 to +40
OSE-PO-0501 External 120-347 PIR 15-40 100 15 3 000 OSI-FSIR-100 Dry, 0 to +40
OSE-PO-0502 External 120-347 PIR 15-40 100 15 3 000 Dry, 0 to +40
OSE-PO-0701 External 120-277 PIR 20 100 15 NA Wet, -40 to +40
OSE-PO-0801 External 347 PIR 20 100 15 NA Wet, -40 to +40
OSI-FO-0301 Internal 120-277 High frequency 32 max 100 20 Disable Dry and wet, -25 to +40
OSI-FO-0601 Internal 120-347 High frequency 25 max 100 30 Disable OSI-RC-MH02 Dry and wet, -35 to +40
OSI-FO-0602 Internal 120-347 High frequency 25 max 100 15 Disable OSI-RC-MH02 Dry and wet, -35 to +40
OSI-FO-0603 Internal 120-347 High frequency 25 max 100 15 100 OSI-RC-MH02 Dry and wet, -35 to +40
BI-LEVEL SENSORS
Detection - On at (Detection Area) % during (Hold Time) min., then (Stand-by Dim level) %
Part number Position Volts(V)
Technology Height(ft)
Detection Area (%)
Hold time(min)
Stand-by Dim level (%)
Daylight min level (lux)
Remote1 Location2
(°C)
OSI-FB-0301 Internal 120-277 High Frequency 32 max 100 20 30 Disable Dry and wet, -25 to +40
OSI-FB-0302 Internal 120-277 High Frequency 32 max 100 20 10 Disable Dry and wet, -25 to +40
OSI-FB-0303 Internal 120-277 High Frequency 32 max 100 20 50 Disable Dry and wet, -25 to +40
OSE-FB-0402 External 120-347 High Frequency 50 max 100 20 30 50 OSI-RC-MH10 Wet, -35 to +40
OSI-FB-0603 Internal 120-347 High Frequency 25 max 100 15 40 Disable OSI-RC-MH02 Dry and wet, -35 to +40
OSI-FB-0604 Internal 120-347 High Frequency 25 max 100 30 40 Disable OSI-RC-MH02 Dry and wet, -35 to +40
OSI-FB-0605 Internal 120-347 High Frequency 25 max 100 15 30 Disable OSI-RC-MH02 Dry and wet, -35 to +40
OSI-FB-0606 Internal 120-347 High Frequency 25 max 100 15 10 Disable OSI-RC-MH02 Dry and wet, -35 to +40
TRI-LEVEL SENSORS
Detection - On at (Detection Area) % during (Hold Time) min., then (Stand-by Dim level) % during (Stand-by period) min. Off
Part number Position Volts(V)
Technology Height(ft)
Detection Area (%)
Hold time(min)
Stand-by Dim level (%)
Stand-by period (min)
Daylight min level (lux)
Remote1 Location2
(°C)
OSI-FT-0301 Internal 120-277 High Frequency 32 max 100 20 30 10 Disable Dry and wet, -25 to +40
OSE-FT-0402 External 120-347 High Frequency 50 max 100 30 30 10 50 OSI-RC-MH10 Wet, -35 to +40
OSI-FT-0601 Internal 120-347 High Frequency 25 max 100 30 30 10 Disable OSI-RC-MH02 Dry and wet, -35 to +401 To be ordered separately.2 Min and max ambient temperature of the fixture with the specific sensor. Please verify fixture temperature on the first page for compatibility with sensor.
For more settings visit www.standardpro.com/documentation/technical-information/
C
VT2-L
Page 4/5
VT2-L • Rev. 2/6/20202233 rue de l’Aviation, Dorval, QC H9P 2X6
514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.standardpro.com
Data is based upon tests performed in a controlled environment. Actual performance can vary depending on operating conditions. All products are subject to change or may be discontinued any time without notice.
MOUNTING TYPE
SUSPENDED(standard)
– V hooks included – Can be suspended with cable or chain
(provided by others)
SURFACE(standard)
– Surface ceiling brackets included
RMB-05Rigid mono point on a bracket with 3/4" (1/2npt)
– Rigid mono point (with bracket support)– Bracket can be predrilled for 1/2'' or 3/4'' NPT,
select appropriate compatible size. Should additional hole on top of luminaire be required, select CH option. (stem provided by others)
RMB-075Rigid mono point on bracket with 1" (3/4npt) center hole drilled on bracket
RMP-05Rigid mono point with 3/4" (1/2npt) center hole drilled in luminaire
– Rigid mono point (pipe through luminaire)– Luminaire can be predrilled for 1/2" or 3/4" NPT,
select appropriate compatible size. A waterproof hub will be provided to preserve IP rating of the fixture. (Stem provided by others)
RMP-075Rigid mono point with 1" (3/4npt) center hole drilled in luminaire
PVPM-05Pivot mount bracket with 3/4" (1/2npt) drilled on bracket
– Two pivot mount brackets installed on rigid mount bracket support. Bracket can be predrilled for 1/2" or 3/4" NPT, select appropriate compatible size. Should additional hole on top of luminaire be required, select desired CH option. (Stem provided by others)
PVPM-075Pivot mount bracket with 1" (3/4npt) drilled on bracket
PVMPivot mount brackets (surface mount)
– Two pivot mount brackets attached to ceiling mount brackets provided with luminaire (surface mount)
18-5/8"
26-3/4"
3-3/4"
6-3/4"
18-5/8"
26-3/4"
3-3/4"
6-3/4"
18-5/8"
26-3/4"
3-3/4"
6-3/4"
DIMENSIONS
Page 5/5
VT2-L • Rev. 2/6/20202233 rue de l’Aviation, Dorval, QC H9P 2X6
514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.standardpro.com
Data is based upon tests performed in a controlled environment. Actual performance can vary depending on operating conditions. All products are subject to change or may be discontinued any time without notice.
Illuminance at a distanceZonal lumen summary
Zonal lumen summary
Polar candela distribution
Center beam fc Beam width
1.7' 266 4.5' 5.3'3.3' 70.6 8.8' 10.3'5.0' 30.8 13.4' 15.6'6.7' 17.1 17.9' 20.9'8.3' 11.2 22.2' 25.9'
10.0' 7.69 26.7' 31.2'
Vert. spread: 106.4° Horiz. spread: 114.6°
PHOTOMETRIC DATA1
VT2-LS1-(H/W)/40K • 2 428.9 lm
VT2-LS2-(H/W)/40K • 4 656.2 lm
Polar candela distribution Illuminance at a distance
Center beam fc Beam width
1.7' 510 4.5' 5.3'3.3' 135 8.8' 10.3'5.0' 59.0 13.4' 15.6'6.7' 32.8 17.9' 20.9'8.3' 21.4 22.2' 25.9'
10.0' 14.7 26.7' 31.2'
Vert. spread: 106.4° Horiz. spread: 114.6°
1 Complete IES files available on our website.
180° 170° 160° 150° 140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°30°20°10°VA: 0°- 0° H
- 90° H
- 22.5° H
- 45° H - 67.5° H
780
650
520
390
260
130
CD: 0
130
260
390
520
650
780
Zone Lumens % Fixture0-30 597.9 24.60-40 974.1 40.10-60 1 707.0 70.360-90 587.4 24.270-100 375.3 15.590-120 121.9 50-90 2 294.4 94.590-180 134.5 5.50-180 2 428.9 100
Zone Lumens % Fixture0-30 1 146.1 24.60-40 1 867.3 40.10-60 3 272.4 70.360-90 1 126.0 24.270-100 719.5 15.590-120 233.6 50-90 4 398.4 94.590-180 257.8 5.50-180 4 656.2 100
180° 170° 160° 150° 140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°30°20°10°VA: 0°- 0° H
- 90° H
- 22.5° H
- 45° H - 67.5° H
1500
1250
1000
750
500
250
CD: 0
250
500
750
1000
1250
1500
VT2-L
Text Field 2031: Page 1:
Text Field 2033: Page 1:
Text Field 2032: Page 1:
Text Field 2035: Page 1:
Text Field 2034: Page 1:
Text Field 1043: Text Field 1041: Text Field 1040: Text Field 1038: