FRIEDRICH.COM THE EXPERTS IN ROOM AIR CONDITIONING
Thru-the-wall Air Conditioners
WallMaster® SeriesThe only perfect fit in 27” sleeves.
WallMaster®
COMMERCIAL GRADE
Thru-the-wall Air Conditioners
A perfect fit in Friedrich and Fedders A & B 27” sleeves
Select MODE, FAN SPEED, MONEY SAVER®, adjust TEMPERATURE and set the TIMER.
FITS SLEEVES 16 3/4" HIGH X 27" WIDE
Installation Features
• Mountsflushwiththeexteriorwallforaneatappearance
• Idealforthickerwallinstallations,wheresidefinsdon’tfit
• Firmgriphandlesonthechassisforeasyinstallationandremovalfromwallsleeve
• Adirectreplacementfor27”sleevesincludingFeddersAandB*.Sleevemeasures27”Wx163/4”H
Safety & Security
• EntryGard™anti-intrusionprotectionsecureschassistosleevetodeter‘kick-in’intrusion
• Powercordcurrentleakageprotected
• ULlistedforsafeoperation
• Insectbarrier
Comfort & Convenience
• Newdesignmakescontrolsmoreaccessible
• Remotecontrol
• 24-hourtimer
• SmartFanauto-adjustsfanspeedtomaintaindesiredtemperature
• Checkfilterreminder
• 3-speedfan
• Auto restart
• Electronicdefrostcontrol
• Individuallyadjustablelouversdirecttheairflowwhereyouneedit
• Washable,antimicrobialfilter
Energy Management
• MoneySaver®settingcyclesthefanwiththecompressor
• ENERGY STAR®qualifiedmodels
• R-410Arefrigerant
Durability & Quality
• Rotarycompressorprovidesquiet,dependableperformance
• Premiumaluminumexteriorgrille
• Denseblowerinsulationblocksoutdoornoise
• Rifledcoppertubing
• Impactresistantfrontcover
• Hightechfinswithsinewavelancedlouversincreaseenergyefficiencybyincreasingsurfaceareaforheatexchange
Optional Accessories
• AGarchitecturalgrilleforusewithWSEsleeve
• Baffleadapterkitforusewithdeepsleeveinstallations(FeddersBsleeves)
• Drainkitforcondensatedisposal
• Internaldrainkitfornewconstructionapplicationswherecondensatedrainsystemisbuilt-in
• WSE sleeveshipswithinsideandoutsidesteelweatherpanelsandstandardexteriorgrille
ADJUSTABLE LOUVERS
*InstallationinFeddersBsleeverequiresabaffleadapterkit-BAK.
ChassisrequiresWSEsleeve(soldandshippedseparately)
Sleeve DimensionsFriedrich
WSE SleeveFedders A Sleeve
Fedders B Sleeve
Height(inches) 16 3/4 16 3/4 16 3/4
Width(inches) 27 27 27
Depth(inches) 16 3/4 16 3/4 19 3/4
FITS EXISTING FEDDERS SLEEVES.
OPTIONAL ACCESSORIES
Height Width DepthHeight
of FrontWidth of
Front
Depth with
Front
Minimum Extension Into Room
with Front
Chassis 15 3/4" 26 1/2" 21" 17 1/4" 27 1/2" 23 1/4" 7 1/2"
CHASSIS DIMENSIONS
IMPORTANT: OperatingtheairconditionerwithincorrectreargrilleorwithoutBaffleAdapterKit(on193/4”deepsleeve)willrecirculatedischargeairandcausecompressoroverloadtotrip.Thiswillcausetheunittoshutdowntemporarilyandmayleadtoprematurecompressorfailure.
CORRECT Vertical Louvers
INCORRECT Horizontal Louvers
WallMaster® WSE Sleeve Exterior Grilles
OptionalArchitecturalGrille-AGPremiumextrudedaluminumgrille.
StandardGrillePremium,stampedsteelgrillewithpowdercoatpaint.ShipswithWSEsleeve.Galvanizedsteelinnerandouterweatherpanelsalsoshipwithsleeve.
Installation AccessoriesDK/DrainKitInstalledatthebackoftheunitandallowsforattachmenttocondensatedisposalsystem,ifnecessaryordesired.
IDK/InternalDrainKitNewconstructionapplicationswhereacondensatedrainsystemhasbeenbuiltintothewallinterior.
BAK/BaffleAdapterKitNecessarywheninstallinginasleevedeeperthan163/4"deep,suchasFeddersBsleeve (193/4"deep).
Model Height Width Depth
Depth with
Front
Minimum Extension
Outside
Thru-the-wall Finished Hole
Height Width Max. Depth
WSESleeve 16 3/4" 27" 16 3/4" 24 1/4" 9/16" 17 1/4" 27 1/4" 15 5/16"
WSE SLEEVE DIMENSIONS
SPECIFICATIONS
BRO_WM_ALL_2016Rev.1 PrintedinUSA
ENERGY STAR® models
HEATING PERFORMANCE: Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating perfor-mance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.
Heat Pump heating information (shown in red) indicates heat pump heating performance. Electric Heat heating information (shown in red) indicates electric heat strip performance. For Heat Pump electric heating performance refer to corresponding Electric Heat model.
LISTEDROOM AIR CONDITIONERS
183H
Power cords are located on front left of WallMaster models.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® models meet the ENERGY STAR® guidelines for energy efficiency.The consumer, through the AHAM Room Air Conditioner Certification Program, can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.EER is the unit’s Energy Efficiency Ratio; CEER is the unit’s Combined Energy Efficiency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on a electricity cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
WallMaster®
Model Number
Circuit Rating
Breaker or T-D Fuse
Plug Face
(NEMA#)
Power Cord
Length (ft.)
WallOutlet
Appearance
WS08D10A,WS10D10AandWS12D10A.
125V-15A 5-15P 6
WS10D30A,WS12D30AandWS15D30A.
250V-15A 6-15P 6
WE10D33,WE12D33andWE15D33A. WY12D33A.
250V-20A 6-20P 6
Model
Carton Dimensions Inches
Height Width Depth
WallMaster®
WSESleeve 18" 27 1/4" 18"
Chassis 193/8" 305/8" 27 1/2"
FriedrichAirConditioningCo.l 10001ReunionPlace,Suite500l SanAntonio,TX78216l 877.599.5665l www.friedrich.com
PLUG FACE/CIRCUIT RATING
Model Cooling Btu Heating BtuVolts Rated
Cooling Amps
Cooling Watts
Heating Watts
Heating Amps EER CEER
Estimated Yearly Energy
Cost COP
Moisture Removal
Pints per Hr. CFM
Net Wt Lbs
Ship Wt Lbs
Cooling Only
WS08D10A 8000 — 115 6.3 748 — — 10.7 10.6 $67 — 1.8 250 93 97
WS10D10A 9700 — 115 8.0 990 — — 9.8 9.7 $89 — 2.4 260 103 107
WS10D30A 10000/9900 — 230/208 4.4/4.6 935/925 — — 10.7/10.7 10.6/10.6 $84 — 2.7 260 101 105
WS12D10A 12000 — 115 10.8 1224 — — 9.8 9.7 $110 — 3.5 295 112 116
WS12D30A 12000/11700 — 230/208 5.5/5.8 1224/1194 — — 9.8/9.8 9.7/9.7 $110 — 3.5 290 109 113
WS15D30A 14500/14300 — 230/208 6.7/7.2 1543/1521 — — 9.4/9.4 9.3/9.3 $140 — 4.8 290 119 123
Cooling with Heat Pump
WY12D33A 11300/11000 8900/8700 230/208 5.5/5.6 1215/1183 1119/1082 5.0/5.3 9.3/9.3 9.3/9.3 $109 2.3/2.3 3.4 275 111 115
Cooling with Electric Heat
WE10D33 10000/9800 11000/9100 230/208 4.5/4.9 1020/1000 3550/2950 16.0/14.7 9.8/9.8 9.7/9.7 $92 — 1.5 260 104 108
WE12D33 12000/11700 11000/9100 230/208 5.5/5.8 1224/1194 3550/2950 16.0/14.7 9.8/9.8 9.7/9.7 $110 — 3.5 290 107 111
WE15D33A 14500/14300 11000/9100 230/208 6.7/7.2 1543/1521 3550/2950 16.0/14.7 9.4/9.4 9.3/9.3 $140 — 4.8 290 119 123