+ All Categories
Home > Documents > WAN Technologies

WAN Technologies

Date post: 18-Jan-2016
Category:
Upload: nola
View: 21 times
Download: 1 times
Share this document with a friend
Description:
WAN Technologies. FRAME RELAY. Frame Relay: An Efficient and Flexible WAN Technology. Frame Relay has become the most widely used WAN technology in the world. Large enterprises, ISPs, and small businesses use Frame Relay, because of its price and flexibility. - PowerPoint PPT Presentation
27
WAN Technologies WAN Technologies FRAME RELAY
Transcript
Page 1: WAN Technologies

WAN TechnologiesWAN Technologies

FRAME RELAY

Page 2: WAN Technologies

Frame Relay: An Efficient and Flexible WAN Frame Relay: An Efficient and Flexible WAN TechnologyTechnology

Frame Relay has become the most widely used WAN technology in the world.

Large enterprises, ISPs, and small businesses use Frame Relay, because of its price and flexibility. Example: Chicago to New York

requires a speed of 256 kb/s. ◦Three other sites need a maximum speed of 48 kb/s connecting to the Chicago headquarters, ◦The connection between the New York and Dallas branch offices requires only 12 kb/s◦What options are possible?

Page 3: WAN Technologies

Solution 1: Using Leased Solution 1: Using Leased LinesLines

The Chicago and New York sites each use a dedicated T1 line (equivalent to 24 DS0 channels) to connect to the switch, while other sites use ISDN connections (56 kb/s). ◦Because the Dallas site connects with both New York and Chicago, it has two locally leased lines. ◦These lines are truly dedicated in that the network provider reserves that line for Span's own use.

Page 4: WAN Technologies

Problems with leased line Problems with leased line solutionsolution

◦Lack of efficiency: Of the 24 DSO channels

available in the T1 connection, the Chicago site only uses seven.

Some carriers offer fractional T1 connections in increments of 64 kb/s, but this requires a specialized multiplexer at the customer end to channelize the signals.

In this case, Span has opted for the full T1 service.

The New York site only uses five of its 24 DSOs.

Dallas needs to connect to Chicago and New York, there are two lines through the CO to each site

Page 5: WAN Technologies

Solution 2: Frame RelaySolution 2: Frame RelayFrame Relay is a more cost-effective option. With Frame Relay,

customers only pay for the local loop, and for the bandwidth they purchase from the network provider.

Distance between nodes is not important. with dedicated lines, customers pay for an end-to-end connection. That includes the local loop and the network link.

Frame Relay's shares bandwidth across a larger base of customers. Typically, a network provider can service 40 or more 56 kb/s customers over one T1 circuit.

Page 6: WAN Technologies

Frame Relay based WANFrame Relay based WAN When use Frame Relay to inter-connect LANs1.A router on each LAN is the DTE. 2.A serial connection, such as a T1/E1 leased line, connects the router to the Frame Relay switch of the carrier at the nearest POP(point of presence) for the carrier. 3.The Frame Relay switch is a DCE device. 4.Network switches move frames from one DTE across the network and deliver frames to other DTEs by way of DCEs.

Page 7: WAN Technologies

Virtual CircuitsVirtual Circuits The connection through a Frame

Relay network between two DTEs is called a virtual circuit (VC).

The circuits are virtual because there is no direct electrical connection from end to end.

With VCs, any single site can communicate with any other single site without using multiple dedicated physical lines.

VCs are identified by DLCIs (data link connection identifier).

DLCI values typically are assigned by the Frame Relay service provider.

Frame Relay DLCIs have local significance, which means that the values themselves are not unique in the Frame Relay WAN.

Page 8: WAN Technologies

Mapping Virtual CircuitsMapping Virtual Circuits In the figure, there is a VC between

the sending and receiving nodes. The VC follows the path A, B, C, and

D. Frame Relay creates a VC by storing

input-port to output-port mapping in the memory of each switch

As the frame moves across the network, Frame Relay labels each VC with a DLCI.

The DLCI is stored in the address field of every frame transmitted to tell the network how the frame should be routed.

The frame uses DLCI 102. It leaves the router (R1) using Port 0 and VC 102.

At switch A, the frame exits Port 1 using VC 432.

This process of VC-port mapping continues through the WAN until the frame reaches its destination at DLCI 201.

Page 9: WAN Technologies

Frame Relay TopologiesFrame Relay Topologies

Page 10: WAN Technologies

Star Topology (Hub and Star Topology (Hub and Spoke)Spoke)

The simplest WAN topology is a star. In this topology, Span Engineering has a

central site in Chicago that acts as a hub and hosts the primary services.

◦ The Span has grown and recently opened an office in San Jose. Using Frame Relay made this expansion relatively easy.

When implementing a star topology with Frame Relay, each remote site has an access link to the Frame Relay cloud with a single VC.

◦ The hub at Chicago has an access link with multiple VCs, one for each remote site.

The lines going out from the cloud represent the connections from the Frame Relay service provider and terminate at the customer premises.

Because Frame Relay costs are not distance related, the hub does not need to be in the geographical center of the network.

Page 11: WAN Technologies

Before a router is able to transmit data over Frame Relay, it needs to know which local DLCI maps to the Layer 3 address of the remote destination.

This address-to-DLCI mapping can be static or dynamic mapping.

Dynamic Mapping (Inverse ARP) Dynamic Inverse ARP relies on the presence of a direct point-to-

point connection between two ends and Inverse ARP to resolve a next hop network protocol address to a local DLCI value.

The Inverse Address Resolution Protocol (ARP) obtains Layer 3 addresses of other stations from Layer 2 addresses, such as the DLCI in Frame Relay networks.

Frame Relay Address Mapping – Frame Relay Address Mapping – Dynamic MappingDynamic Mapping

Page 12: WAN Technologies

Frame Relay Address Mapping-Static Frame Relay Address Mapping-Static MappingMappingStatic Mapping (Inverse ARP) static mapping maps the next hop protocol address to

a local DLCI hub-and-spoke topology uses static address mapping

on the spoke routers to provide spoke-to-spoke reachability

Page 13: WAN Technologies

Frame Relay address Frame Relay address mappingmapping

Static Mapping

Page 14: WAN Technologies

Configuring FRConfiguring FR

Page 15: WAN Technologies

Configuring FR (contd.)Configuring FR (contd.)

Page 16: WAN Technologies

Configure a static Frame Relay Configure a static Frame Relay mapmap

Page 17: WAN Technologies

Frame Relay NBMA topologyFrame Relay NBMA topology

Page 18: WAN Technologies

Frame Relay Frame Relay SubinterfacesSubinterfaces

Page 19: WAN Technologies

Solving Reachability Issues: Solving Reachability Issues: SubinterfacesSubinterfaces

Frame Relay can partition a physical interface into multiple virtual interfaces called subinterfaces.

To enable the forwarding of broadcast routing updates in a Frame Relay network, you can configure the router with logically assigned subinterfaces

Point-to-point - A single point-to-point subinterface establishes one PVC connection to another physical interface or subinterface on a remote router.

Each pair of the point-to-point routers is on its own subnet, and each point-to-point subinterface has a single DLCI.

Multipoint - A single multipoint subinterface establishes multiple PVC connections to multiple physical interfaces or subinterfaces on remote routers.

Page 20: WAN Technologies

Frame Relay subinterfaces ensures that a physical interface is treated as multiple virtual interfaces.

To create a subinterface, Specify the port number, followed by a period (.) and the subinterface number.

◦R1(config-if)#interface serial 0/0/0.103 point-to-point◦To make troubleshooting easier, use the DLCI as the subinterface number. ◦You must also specify whether the interface is point-to-point or point-to-multipoint using either the multipoint or point-to-point keyword.

The DLCI is also required for multipoint subinterfaces for which Inverse ARP is enabled.

◦R1(config-subif)#frame-relay interface-dlci 103.◦DLCI number is not required for multipoint subinterfaces configured with static frame relay maps. ◦The DLCI range from 16 to 991.

Configuring Frame Relay Configuring Frame Relay SubinterfacesSubinterfaces

Page 21: WAN Technologies

Configuring Frame Relay SubinterfacesConfiguring Frame Relay Subinterfaces

In the figure, R1 has two point-to-point subinterfaces, each on a different subnet.

◦s0/0.0.102 connects to R2, ◦s0/0/0.103 connects to R3. ◦Step 1. Remove any network layer

address assigned to the physical interface. ◦Step 2. Configure Frame Relay encapsulation

on the physical interface encapsulation frame-relay.

◦Step 3. For each of the PVCs, create a subinterface. ◦Step 4. Configure an IP address for the

interface and set the bandwidth.◦Step 5. Configure the local DLCI on the subinterface using the frame-relay interface-dlci <>

Page 22: WAN Technologies

Example: Point-to-point sub-Example: Point-to-point sub-interfacesinterfaces

Use the frame-relay interface-dlci for local DLCI on the subinterface

Page 23: WAN Technologies

Bandwidth controlBandwidth control

Page 24: WAN Technologies

The following commands can be used to help verify frame relay configuration

–Show interfaces–Show frame-relay lmi–Show frame-relay pvc ###–Show frame-relay map

Use the following command to help troubleshoot a frame relay configuration

–Debug frame-relay lmi

Troubleshooting Frame Troubleshooting Frame RelayRelay

Page 25: WAN Technologies

Verifying FR configuration.Verifying FR configuration.

Page 26: WAN Technologies

SummarySummaryFrame relay is the most widely used WAN

technology because it:–Provides greater bandwidth than leased line–Reduces cost because it uses less equipment–Easy to implement

Frame relay is associated with layer 2 of the OSI model and encapsulates data packets in a frame relay frame

Frame relay is configured on virtual circuits–These virtual circuits may be identified by a DLCI

Frame relay uses inverse ARP to map DLCI to IP addresses

Page 27: WAN Technologies

SummarySummaryConfiguring frame relay requires

–Enable frame relay encapsulation–Configuring either static or dynamic mapping–Considering split horizon problems that develop when multiple VCs are placed on a single physical interface


Recommended