7
Equipment tag: P-23202 B Motor Data: AC induction motor, horizontal Motor Speed 2980 rpm No of Poles 2 Lf: 49.6 Hz 150 kW DE bearing 6316 C4 frequencies: BPFO BPFI FTF BSF 2X BSF 153 244 19.1 102 205 NDE bearing 6316 C4 frequencies: BPFO BPFI FTF BSF 2X BSF 153 244 19.1 102 205
Transcript
Page 1:  · Web viewAuthor Mohammed Abdullah Ali Al-Obaidi Created Date 07/09/2020 09:53:00 Last modified by Mohammed Al-Obaidi ...

Equipment tag: P-23202 BMotor Data:AC induction motor, horizontalMotor Speed 2980 rpmNo of Poles 2Lf: 49.6 Hz150 kWDE bearing 6316 C4 frequencies:

BPFO BPFI FTF BSF 2X BSF153 244 19.1 102 205

NDE bearing 6316 C4 frequencies:BPFO BPFI FTF BSF 2X BSF153 244 19.1 102 205

Page 2:  · Web viewAuthor Mohammed Abdullah Ali Al-Obaidi Created Date 07/09/2020 09:53:00 Last modified by Mohammed Al-Obaidi ...

Condition history of the motor:

Page 3:  · Web viewAuthor Mohammed Abdullah Ali Al-Obaidi Created Date 07/09/2020 09:53:00 Last modified by Mohammed Al-Obaidi ...

Condition history of the pump:

Page 4:  · Web viewAuthor Mohammed Abdullah Ali Al-Obaidi Created Date 07/09/2020 09:53:00 Last modified by Mohammed Al-Obaidi ...

Findings:

A. Pump Parameters:

B. High MOH/MIH observed:

C. Misalignment is suspected due to the following symptoms:1. 1X & 2X peaks of the motor running speed are dominant in the fft of MOH & MIH.

MIH Spectrum:

2X of motor

Page 5:  · Web viewAuthor Mohammed Abdullah Ali Al-Obaidi Created Date 07/09/2020 09:53:00 Last modified by Mohammed Al-Obaidi ...

MOH Spectrum:

2. The horizontal cross phase measurement across the coupling is ~30 degree. In combination with the high peaks of the spectra in point 1 (misalignment symptom), it maight be indicating that the phase is shifted from the radial to the axial direction.The Axial cross phase measurement has shown a 174 degree phase shift across the coupling. As a companion to the point 1, this axial phase shift is much indicative of the misalignment.

2X of motor

Page 6:  · Web viewAuthor Mohammed Abdullah Ali Al-Obaidi Created Date 07/09/2020 09:53:00 Last modified by Mohammed Al-Obaidi ...

D. The lube oil of the pump is to the proper level.E. The last greasing for the motors was done on 03.2020. bearing grease starvation is suspected

due to the following indications:1. smearing (high-pitched) sound can be heard from the motor.2. Pulses are observed in the time waveform signal which might be an indication of a

bearing lubrication problem. And also it is a sign that the bearing is subjecting to shocks (that is also could be a misalignment effect on the bearing) The following TWF captured from MIH

F. The mechanical seal: large salt accomulation on the gland.

Recommendations:

1. M6 notification will be created to change the monitoring frequency to 2 weekly.2. M1 notification will be created to clean the mechancial seal gland on pump switch off

opportunity.3. Greasing the motor bearings may decrease the vibration. Grease shot should be accompanied

by live vibration monitoring of MIH/MOH. Greasing should be stopped if the vibration will be increased.

4. Before checking/rectifying the misalignment, live vibration monitoring of the MOH/MIH during the switch off to verify if the 1x & 2X peaks are motor running speed peaks or electrical fault peaks (line frequency peaks Lf/2XLf).

5. The misalignment to be verified then rectified.6. If high vibration is observed after the alignment, motor solo run test should be carried out for

further investigation.


Recommended