® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Wireless Stairwell Fixture
369338b 1 06.04.12
®
Wireless Stairwell Fixture Solution
The stairwell fixture works with a Lutron Radio Powr SavrTM wireless occupancy sensor (sold separately) to save energy and lower energy costs. The easy-to-install fixture includes a preprogrammed dimming ballast and RF receiver that adjusts light levels based on stairwell occupancy.
Features
•Universalinputvoltage120/277V•Ballasthasoccupiedandunoccupiedlevelsthatcan
be preset to a specific location's code requirements for lighted stairwells
• IntegralwirelesscontroldevicewithRFreceiver• Integralfailsafedefaultstooccupiedlightlevelifsensoris
missing or malfunctioning•Rotarylockinglampholders•Alsoavailable:Emergencyballastbatterybackup•Fullyassembledfixturecomesreadytoinstall•Powerfactorgreaterthan0.9•Totalharmonicdistortion<10%•ClassAsoundrating•Novisiblelampflicker•ApprovedtoULandCSAstandards
Environment
•10to40°C(50to104°F)•Relativehumiditylessthan90%non-condensing•Forindooruseonly
RF Range (occupancy sensor to wireless control)
•60foot(18m)lineofsight•30foot(9m)throughnormalconstruction
Fixture Specifications
•Ceilingorwallsurfacemount•Housingandswitchbox:20gaugewhitehigh-
reflective powder coat steel Endcaps:18gaugewhitehigh-reflectivepowdercoat steel
•Lutronballastwithadjustablehigh-endoccupiedlevelandlow-endunoccupiedlevelwith2availablefactorydefaultsettings: 10%unoccupied;50%occupied
20%unoccupied;80%occupied•Prismaticacryliclens•120/277V universal input voltage•CompatiblewithallLutronRadioPowrSavrTM
wireless occupancy sensors
Lamps
•UseonlywithlampsconformingtotheIEC60081/60901specification;LutronrecommendsSylvania,GE,orPhilipslampsforproperdimmingperformance
•Refertolampmanufacturerforlampburn-in requirements
•Lampsarenotincludedwithfixture•2-foot,3-foot,and4-footfixturesavailable;1or2lamps Lampoptions:T8,T5HE,T5HO,reducedwattageT8
•8-footfixtureavailablein2-lampor4-lampT8only
Wireless control device
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Wireless Stairwell Fixture
369338b 2 06.04.12
®
· Press the tapswitch once to continue to the unoccupiedlightlevelsetting;seethetablebelowfor the approximate light levels as displayed by the LEDs.
· Press the tapswitch to save your light level settings and return the wireless control device to normal operation mode.
Note:Programmingmodewilltimeoutafter30seconds if no buttons are pressed on the wireless control device.
Programming and Functionality
The wireless control device can be programmed to performfourfunctions:
1.Burn-in. Pull out the air gap switch at the bottom of the wirelesscontroldevice.Thelightswillgotofullon(100%).Consultlampmanufacturerforrecommendedburn-inperiod.
2.Return to factory settings. To reset the occupied and unoccupied light levels to their factory settings, perform thefollowingsequenceusingthetapswitch: Tap3times,holdingthetapswitchdownonthethird
tap. The lights will cycle up and down. Releasethetapswitch,thenimmediatelytap3times. Thelightswillcycleupanddown3timestoverifyyouhave returned to factory settings.
Note: Returning the wireless control device to factory settings will disassociate the wireless control device from any associated sensors.
3.Associate with sensor. Press and hold the tapswitch onthewirelesscontroldevicefor6seconds,untiltheLEDsflash.Thenpressandholdthe"Off"or"LightsOn/Off"buttononthesensorfor6seconds,untilthelenson the sensor flashes orange. The sensor and lights will flash to confirm association.
4.Set desired occupied and unoccupied light levels. Press and hold the tapswitch and the up rocker at the sametimefor3secondstoenterprogrammingmode. · To set the desired occupied light level, use the up and
down rockers to raise or lower the light level. The table below shows the approximate light levels, as displayed bytheLEDs.
LED Display
= on = off
Occupied Setting
40% 50% 60% 70% 80% 90% 100%
Unoccupied Setting
1% 5% 10% 20% 30% 40% 50%
Tapswitch
UpRocker
DownRocker
Airgapswitch
LEDs
Note: To set reduced wattage T8lampstotheir10%lowendlight level, program the unoccupied light level of the wirelesscontroldeviceto1%.
Wireless control device
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Wireless Stairwell Fixture
369338b 3 06.04.12
®
Photometric Data
For detailed photometric data, see www.lutron.com
Candela Plot Candela Table
0 15 30
45
60
75
90
105
120 135 150 165 180
15 30
45
60
75
90
105
120 135 150 165
250
500
750
1000
4100 K Data Zonal Lumen Summary
4 foot 2-lamp 32 W T8 stairwell fixture Tested with clear prismatic lensLightOutput 4406Lumens
Wattage 58.84
Lumens/Watt 74.88
ColorTemperature 4100K
Zone Lumens % of Luminaire0-30 779 17.7
0-40 1301 29.5
0-60 2312 52.5
0-90 3403 77.2
90-180 1003 22.8
0-180 4406 100.0
0 90
0 937 937
5 929 946
15 900 981
25 841 979
35 748 883
45 619 750
55 429 614
65 195 588
75 79 575
85 23 497
90 1 426
Dimensions
513in(1299mm)
47^in(1218mm)
396in(1013mm)47 in (103mm)
73 in (181mm)
6in(22mm)KOprovided at end opposite the switch
1in(6mm)dia.mountinghole(4x)
(4-footfixtureshown)
44 in (111mm)
36 in (98mm)
6in(22mm)KOtyp.
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Wireless Stairwell Fixture
369338b 4 06.04.12
®
Ordering Guide
Select appropriate code in each column to complete model number. Example:FXSWXX12CP114U51XXXXWH
PRODUCT FAMILY TYPE SIZE LENS LAMPSLAMP TYPE/WATTAGE
REGION CONTROLS MOUNTING OPTIONS COLOR/FINISH
FXFixture
SWStairwell
XXStandard
121 x 2 ft
CPClear prismatic
11 lamp
1414 W T5HE, 2 ft
UUL—North America
5150% high end, 10% low end
XXStandard
XXNone
WHMatte white
131 x 3 ft
OAOpal acrylic
22 lamps
1717 W T8, 2 ft
8280% high end, 20% low end
E1T8 emergency ballast (not available for 2 ft fixture)
141 x 4 ft
44 lamps (1 x 8 ft only)
2424 W T5HO, 2 ft
E3T5HE emergency ballast (not available for 2 ft fixture)
181 x 8 ft
2121 W T5HE, 3 ft
E5T5HO emergency ballast (not available for 2 ft fixture)
2525 W T8, 3 ft
2828 W T5HE, 4 ft
3232 W T8, 4 ft
3939 W T5HO, 3 ft
5454 W T5HO, 4 ft
RW 25,28,30WT8reduced wattage, 4ft