+ All Categories
Home > Documents > XT Line Cabinets - X-TremeSeries · 1198 x 1654 x 631 mm 1178 x 1634 x 631 mm Net Volume Non...

XT Line Cabinets - X-TremeSeries · 1198 x 1654 x 631 mm 1178 x 1634 x 631 mm Net Volume Non...

Date post: 02-May-2018
Category:
Upload: voliem
View: 222 times
Download: 0 times
Share this document with a friend
6
Physical External Dimensions (WxHxD) 1200 x 1990 x 750 mm Internal Dimensions (WxHxD) Non Isolated Isolated 1198 x 1654 x 631 mm 1178 x 1634 x 631 mm Net Volume Non Isolated Isolated 1250 lt 1215 lt Weight (Depends on Configuration) 190 Kg Max. Load Capacity of a Shelf 50 Kg Height from Ground 30 mm Body Material Electrostatic Painted Steel, Stainless Steel Interior Panel Door Glass 24 mm Insulating Thermal Glass Shelves Stainless Steel (10 pcs.) Electrical Voltage 220 -240 V AC 50 Hz – 110 V AC 60 Hz (±10%) Current / Max Power 10 A – 16 A (Maximum) / 2200 W Max. Average Power Consumption 50 W / Hour (Depends on Configuration) Max Power Consumption / Hour (Depends on Configuration) Base Light N2 1th Dryer 2th Dryer 40° C Heater 60° C Heater XT Line Cabinets 10 W 58 W 5 W 750 W 750 W 1500 W 1500 W Operational Humidity Set Range 0,5% - 50% RH (0,5 % to Ambient) Temperature Set Range (Optional) 45 °C – 60 °C (Ambient to Set Value) Time to Reach to Set Humidity Level from Ambient <7 min. with one Dryer Number of Doors 4 or 2 Door Lock Automatic Locks with Password (Optional) Display & Control Panel Display Type Touch Screen LCD Panel Color Blue Backlight Type LED, White Number of Dots 240 x 128 (horizontal x vertical) Active Area 107,98 x 57,58 mm Control Panel Type Touch Screen LCD Panel Operating Force <100 g Durability >1.200.000 times pen selections (Force:250g, Speed:2cm/sec) Insulation Resistance >10 MΩ (DC 25 V) Linearity ≤ ±1,5% for both X and Y axis Measurements Relative Humidity Measure- ment Location Cabinet inside (Standard), Cabinet outside (Optional) Range 0 – 99 % RH Accuracy ± 0.3 % RH (0…20 % RH) ± 1.5 % RH (20…99% RH) (After Calibration) (Indoor Sensor) Resolution 0.01 % RH <10 % RH -- 0.1 %RH > 10% RH (Indoor Sensor) Temperature Measurement Location Cabinet inside (Standard), Cabinet outside (Optional) Range -20 - +90 °C Temperature Measurement Accuracy ± 0,5 °C (at 25 °C) Resolution 0.1 °C Date & Time Date (DD.MM.YY) and Time (hh.mm.ss) display with RTC XT Line Cabinets
Transcript

Physical

External Dimensions (WxHxD) 1200 x 1990 x 750 mm

Internal Dimensions (WxHxD)Non Isolated Isolated

1198 x 1654 x 631 mm 1178 x 1634 x 631 mm

Net VolumeNon Isolated Isolated

1250 lt 1215 lt

Weight (Depends on Configuration) 190 Kg

Max. Load Capacity of a Shelf 50 Kg

Height from Ground 30 mm

Body Material Electrostatic Painted Steel, Stainless Steel Interior Panel

Door Glass 24 mm Insulating Thermal Glass

Shelves Stainless Steel (10 pcs.)

Electrical

Voltage 220 -240 V AC 50 Hz – 110 V AC 60 Hz (±10%)

Current / Max Power 10 A – 16 A (Maximum) / 2200 W Max.

Average Power Consumption 50 W / Hour (Depends on Configuration)

Max Power Consumption / Hour (Depends on Configuration) Base Light N2 1th Dryer 2th Dryer 40° C Heater60° C Heater

XT Line Cabinets 10 W 58 W 5 W 750 W 750 W 1500 W 1500 W

Operational

Humidity Set Range 0,5% - 50% RH (0,5 % to Ambient)

Temperature Set Range (Optional) 45 °C – 60 °C (Ambient to Set Value)

Time to Reach to Set Humidity Level from Ambient <7 min. with one Dryer

Number of Doors 4 or 2

Door Lock Automatic Locks with Password (Optional)

Display & Control Panel

Display

Type Touch Screen LCD Panel

Color Blue

Backlight Type LED, White

Number of Dots 240 x 128 (horizontal x vertical)

Active Area 107,98 x 57,58 mm

Control Panel

Type Touch Screen LCD Panel

Operating Force <100 g

Durability >1.200.000 times pen selections (Force:250g, Speed:2cm/sec)

Insulation Resistance >10 MΩ (DC 25 V)

Linearity ≤ ±1,5% for both X and Y axis

Measurements

Relative Humidity Measure-ment

Location Cabinet inside (Standard), Cabinet outside (Optional)

Range 0 – 99 % RH

Accuracy ± 0.3 % RH (0…20 % RH) ± 1.5 % RH (20…99% RH) (After Calibration) (Indoor Sensor)

Resolution 0.01 % RH <10 % RH -- 0.1 %RH > 10% RH (Indoor Sensor)

Temperature MeasurementLocation Cabinet inside (Standard), Cabinet outside (Optional)

Range -20 - +90 °C

Temperature MeasurementAccuracy ± 0,5 °C (at 25 °C)

Resolution 0.1 °C

Date & Time Date (DD.MM.YY) and Time (hh.mm.ss) display with RTC

XT Line Cabinets

Alarm Functions

Alarm Type Standard Internal Buzzer, Optional Alarm Light Bar

Alarm Duration Adjustable, Internal Buzzer: 5-255 sec. Alarm L. Bar: 1-60 min.

Humidity Level Alarm Adjustable Offset: 0% - 40% Adjustable Time After Door Close: 1 – 60 minutes Temperature Level Alarm

Door Left Open Alarm Adjustable Time to Alarm: 10 – 240 seconds

Environmental

Relative Humidity 1% - 90% RH

Temperature 15 °C – 30 °C

Protection Class IP 20

Optional Features

Secondary Dehumidifier Unit (Optional)

Advantage 60 % decrease in time to reach to set humidity level

Usage As Standby, Sharing Drying Task With Intervals

Heater (Optional)

Capacity 2 x 750 W

Heating Type Electrical, Heating Elements and Fans

Insulation Material Elastomeric Rubber Foam, Thermal Conductivity <0,036 W/mK

Control Automatic

Lighting (Optional)

Location Interior

Capacity & Type 58 W, Fluorescent daylight

Control Automated: Display Touch, Motion Sensor or Door Open Triggered

Light ON Time After Last Trigger, Adjustable: 0 – 240 minutes

Automatic Door Lock (Op-tional)

Number of Locks 1 Lock at each Door

Lock Type Solenoid Controlled, Open / Locked Status Monitoring

Control Access Code Used as Password

Shelve Capacity

Material Stainless Steel

Maximum / Cabinet 42 pcs. (2 in a row)

Minimum Shelf Height 60 mm

Mounting/Demounting Easy with Shelf Holder Parts, No Tools Required

Customized Storage Options (Depends on Customers’ Requirement)

Sliding Drawers

Sliding Feeder Holders

Outdoor Sensor (Optional)

Location Integrated to Body on Top of Right Side of Cabinet

Measurement Relative Humidity, Temperature

Specifications Same as Cabinet Inside Sensor Except Accuracy of ± 1.5 %Rh

Alarm Light Bar (Optional)

Type Buzzer and Two Colored Lights, Magnetic Base

Buzzer Noise Level 70 dB (A)

Light Type and Colors Yellow and red, 12 V, 5 W lamps

Shape and Visibility Cylindrical, 360° View

Mounting Easy Attachable With Magnetic Base Plate, Built-In Screw Holes

Connection 4-Pin XLR Connector Behind Cabinet

Datalogger Card with Memory (Optional)

Memory Capacity: 4MB

Total Logging Time Capacity

Record 15 sec. Interval

Record 30 sec. Interval Record 45 sec. Interval Record 60 sec. Interval

22 days 18 hours 8 minutes

45 days 12 hours 16 minutes

68 days 6 hours 24 minutes

91 days 0 hours 32 minutes

Communication Port (Optional)

USB (AF Type) Connector Right Side of the Cabinet (Optional)

Çetin Emeç Bul. 1333. Sk. No.5Öveçler 06460 Ankara-TÜRKİYETel: 0.312.472 20 60Web: [email protected]

Manufactured by;

Çamlıca Mahallesi, Anadolu Bulvarı No:16Regnum Ticaret Merkezi, B Blok No: 5/1 06200 Yenimahalle / ANKARA - TURKEY

Web: [email protected]

Body Material Electrostatic Painted Steel, Stainless Steel Interior Panel

Door Glass 24 mm Insulating Thermal Glass

Shelves -

XS Line CabinetsXS-300 XS-450 Stainless Steel (2pcs.)

XS-600 XS-900 Stainless Steel (5 pcs.)

Physical

External Dimensions (WxHxD)

XS Line Cabinets

XS-300 606 x 1128 x 750 mm

XS-450 606 x 1128 x 1050 mm

XS-600 606 x 1990 x 750 mm

XS-900 606 x 1990 x 1050 mm

Internal Dimensions (WxHxD) Non Isolated Isolated

XS Line Cabinets

XS-300 604 x 792 x 630 mm 584 x 772 x 630 mm

XS-450 604 x 792 x 930 mm 584 x 772 x 930 mm

XS-600 604 x 1654 x 630 mm 584 x 1634 x 630 mm

XS-900 604 x 1654 x 930 mm 584 x1634 x 930 mm

Net Volume Non Isolated Isolated

XS Line Cabinets

XS-300 300 lt 285 lt

XS-450 440 lt 420 lt

XS-600 625 lt 600 lt

XS-900 925 lt 890 lt

Weight (Depends on Configuration)

XS Line Cabinets

XS-300 90 Kg

XS-450 115 Kg

XS-600 134 Kg

XS-900 160 Kg

Max. Load Capacity of a Shelf 50 Kg

Height from Ground 30 mm

Display

Type Graphic LCD with Backlight

Color Blue

Backlight Type LED, White

Number of Dots 240 x 128 (horizontal x vertical)

Active Area 107,98 x 57,58 mm

Electrical

Voltage 220 -240 V AC 50 Hz – 110 V AC 60 Hz (±10%)

Current / Max Power 10 A – 16 A (Maximum) / 2200 W Max.

Average Power Consumption 50 W / Hour (Depends on Configuration)

Max Power Consumption / Hour

(Depends on Configuration)Base Light N2 1th Dryer 2th Dryer 40° C Heater 60° C Heater

XS Line Cabinets

XS-300 10 W - 5 W 750 W - 1500 W 1500 W

XS-450 10 W - 5 W 750 W - 1500 W 1500 W

XS-600 10 W - 5 W 750 W - 1500 W 1500 W

XS-900 10 W - 5 W 750 W - 1500 W 1500 W

Operational

Humidity Set Range 0,5%-50% RH ( %0,5 to Ambient)

Temperature Set Range (Optional) 20 °C – 45 °C (Optional 60 °C) (Ambient to Set Value)

Time to Reach to Set Humidity Level from Ambient <7 min. with one Dryer

Number of DoorsXS – 300 / 600 1

XS – 450 / 900 2

Door Lock Automatic Locks with Password (Optional)

XS Line Cabinets

Control Panel

Type Touch Screen LCD Panel

Operating Force <100 g

Durability >1.200.000 times pen selections (Force:250g, Speed:2cm/sec)

Insulation Resistance >10 MΩ (DC 25 V)

Linearity ≤ ±1,5% for both X and Y axis

Display & Control Panel

Measurements

Relative Humidity Measurement

Location Cabinet inside (Standard), Cabinet outside (Optional)

Range 0 – 99 % RH

Accuracy ± 0.3 % RH (0…20 % RH) ± 1.5 % RH (20…99% RH) (After Calibration) (Indoor Sensor)

Resolution 0.01 % RH <10 % RH -- 0.1 %RH > 10% RH (Indoor Sensor)

Temperature Measurement

Location Cabinet inside (Standard), Cabinet outside (Optional)

Range -20 - +90 °C

Temperature Measurement

Accuracy ± 0,5 °C (at 25 °C)

Resolution 0.1 °C

Date & Time Date (DD.MM.YY) and Time (hh.mm.ss) display with RTC

Alarm Functions

Alarm Type Standard Internal Buzzer, Optional Alarm Light Bar

Alarm DurationAdjustable, Internal Buzzer: 5-255 sec. Alarm Light Bar: 1-60 min.

Humidity Level Alarm Adjustable Offset: 0% - 40% Adjustable Time After Door Close: 1 – 60 minutes Temperature Level Alarm

Door Left Open Alarm Adjustable Time to Alarm: 10 – 240 seconds

Environmental

Relative Humidity 1% - 90% RH

Temperature 15 °C – 30 °C

Protection Class IP 20

Optional Features

Secondary Dehumidifier Unit (Optional)

Advantage 60 % decrease in time to reach to set humidity level

Usage As Standby, Sharing Drying Task With Intervals

Heater (Optional)

Capacity 2 x 750 W

Heating Type Electrical, Heating Elements and Fans

Insulation Material Elastomeric Rubber Foam, Thermal Conductivity <0,036 W/mK

Control Automatic

Lighting (Opti-onal)

Location Interior

Capacity & Type 58 W, Fluorescent daylight

Control Automated: Display Touch, Motion Sensor or Door Open Triggered

Light ON Time After Last Trigger, Adjustable: 0 – 240 minutes

Automatic Door Lock (Optional)

Number of Locks 1 Lock at each Door

Lock Type Solenoid Controlled, Open / Locked Status Monitoring

Control Access Code Used as Password

Shelve

Capacity

Material Stainless Steel

Maximum / Cabinet XS 300-450 9 pieces.

600-900 21 pieces.

Minimum Shelf Height 60 mm

Mounting/Demounting Easy with Shelf Holder Parts, No Tools Required

Customized Storage Options(Depends on Customers’ Requirement)Sliding Drawers

Sliding Feeder Holders

Outdoor Sensor (Optional)

Location Integrated to Body on Top of Right Side of Cabinet

Measurement Relative Humidity, Temperature

Specifications Same as Cabinet Inside Sensor Except Accuracy of ± 1.5 %Rh

Alarm Light Bar (Optional)

Type Buzzer and Two Colored Lights, Magnetic Base

Buzzer Noise Level 70 dB (A)

Light Type and Colors Yellow and red, 12 V, 5 W lamps

Shape and Visibility Cylindrical, 360° View

Mounting Easy Attachable With Magnetic Base Plate, Built-In Screw Holes

Connection 4-Pin XLR Connector Behind Cabinet

Datalogger Card with Memory (Optional)

Memory Capacity: 4MB

Total Logging Time Capacity

Record 15 sec. Interval Record 30 sec. Interval

Record 45 sec. Interval

Record 60 sec. Interval

22 days 18 hours 8 minutes

45 days 12 hours 16 minutes

68 days 6 hours 24 minutes

91 days 0 hours 32 minutes

Communication Port (Optional) USB (AF Type) Connector Right Side of the Cabinet (Optional)

Çetin Emeç Bul. 1333. Sk. No.5Öveçler 06460 Ankara-TÜRKİYETel: 0.312.472 20 60Web: [email protected]

Manufactured by;

Çamlıca Mahallesi, Anadolu Bulvarı No:16Regnum Ticaret Merkezi, B Blok No: 5/1 06200 Yenimahalle / ANKARA - TURKEY

Web: [email protected]

XL Line Cabinets

Physical

External Dimensions (WxHxD) 1200 x 1990 x 1050 mm

Internal Dimensions (WxHxD)Non Isolated Isolated

1198 x 1654 x 931 mm 1178x1634x911

Net VolumeNon Isolated Isolated

1840 lt 1805 lt

Weight (Depends on Configuration) 280 Kg

Max. Load Capacity of a Shelf 50 Kg

Height from Ground 30 mm

Body Material Electrostatic Painted Steel, Stainless Steel Interior Panel

Door Glass 24 mm Insulating Thermal Glass

Shelves Stainless Steel (10 pcs.)

Electrical

Voltage 220 -240 V AC 50 Hz – 110 V AC 60 Hz (±10%)

Current / Max Power 10 A – 16 A (Maximum) / 2200 W Max.

Average Power Consumption 50 W / Hour (Depends on Configuration)

Max Power Consumption / Hour(Depends on Configuration)

Base Light N2 1th Dryer 2th Dryer 40° C Heater 60° C Heater

XL Line Cabinets 10 W 58 W 5 W 750 W 750 W 1500 W 1500 W

Operational

Humidity Set Range 0,5% - 50% RH (0,5 % to Ambient)

Temperature Set Range (Optional) 45 °C – 60 °C (Ambient to Set Value)

Time to Reach to Set Humidity Level from Ambient <7 min. with one Dryer

Number of Doors 2 - 4

Door Lock Automatic Locks with Password (Optional)

Display & Control Panel

Display

Type Graphic LCD with Backlight

Color Blue

Backlight Type LED, White

Number of Dots 240 x 128 (horizontal x vertical)

Active Area 107,98 x 57,58 mm

Control Panel

Type Touch Screen LCD Panel

Operating Force <100 g

Durability >1.200.000 times pen selections (Force:250g, Speed:2cm/sec)

Insulation Resistance >10 MΩ (DC 25 V)

Linearity ≤ ±1,5% for both X and Y axis

Measurements

Relative Humidity Measurement

Location Cabinet inside (Standard), Cabinet outside (Optional)

Range 0 – 99 % RH

Accuracy ± 0.3 % RH (0…20 % RH) ± 1.5 % RH (20…99% RH) (After Calibration) (Indoor Sensor)

Resolution 0.01 % RH <10 % RH -- 0.1 %RH > 10% RH (Indoor Sensor)

Temperature Measurement

Location Cabinet inside (Standard), Cabinet outside (Optional)

Range -20 - +90 °C

Accuracy ± 0,5 °C (at 25 °C)

Resolution 0.1 °C

Date & Time Date (DD.MM.YY) and Time (hh.mm.ss) display with RTC

Alarm Functions

Alarm Type Standard Internal Buzzer, Optional Alarm Light Bar

Alarm Duration Adjustable, Internal Buzzer: 5-255 sec. Alarm L. Bar: 1-60 min.

Humidity Level Alarm Adjustable Offset: 0% - 40% Adjustable Time After Door Close: 1 – 60 minutes Temperature Level Alarm

Door Left Open Alarm Adjustable Time to Alarm: 10 – 240 seconds

Environmental

Relative Humidity 1% - 90% RH

Temperature 15 °C – 30 °C

Protection Class IP 20

Optional Features

Secondary Dehumidifier Unit (Optional)

Advantage 60 % decrease in time to reach to set humidity level

Usage As Standby, Sharing Drying Task With Intervals

Heater (Optional)

Capacity 2 x 750 W

Heating Type Electrical, Heating Elements and Fans

Insulation Material Elastomeric Rubber Foam, Thermal Conductivity <0,036 W/mK

Control Automatic

Lighting (Optional)

Location Interior

Capacity & Type 58 W, Fluorescent daylight

Control Automated: Display Touch, Motion Sensor or Door Open Triggered

Light ON Time After Last Trigger, Adjustable: 0 – 240 minutes

Automatic Door Lock (Optional)

Number of Locks 1 Lock at each Door

Lock Type Solenoid Controlled, Open / Locked Status Monitoring

Control Access Code Used as Password

ShelveCapacity

Material Stainless Steel

Maximum / Cabinet 42 pcs. (2 in a row)

Minimum Shelf Height 60 mm

Mounting/Demounting Easy with Shelf Holder Parts, No Tools Required

Customized Storage Options(Depends on Customers’ Requirement)

Sliding Drawers

Sliding Feeder Holders

Outdoor Sensor (Optional)

Location Integrated to Body on Top of Right Side of Cabinet

Measurement Relative Humidity, Temperature

Specifications Same as Cabinet Inside Sensor Except Accuracy of ± 1.5 %Rh

Alarm Light Bar (Optional)

Type Buzzer and Two Colored Lights, Magnetic Base

Buzzer Noise Level 70 dB (A)

Light Type and Colors Yellow and red, 12 V, 5 W lamps

Shape and Visibility Cylindrical, 360° View

Mounting Easy Attachable With Magnetic Base Plate, Built-In Screw Holes

Connection 4-Pin XLR Connector Behind Cabinet

Datalogger Card with Memory (Optional)

Memory Capacity: 4MB

Total Logging Time Capacity

Record 15 sec. Interval Record 30 sec. Interval Record 45 sec. Interval Record 60 sec. Interval

22 days18 hours8 minutes

45 days12 hours16 minutes

68 days6 hours24 minutes

91 days0 hours32 minutes

Communication Port (Optional)

USB (AF Type) Connector Right Side ofß the Cabinet (Optional)

Çetin Emeç Bul. 1333. Sk. No.5Öveçler 06460 Ankara-TÜRKİYETel: 0.312.472 20 60Web: [email protected]

Manufactured by;

Çamlıca Mahallesi, Anadolu Bulvarı No:16Regnum Ticaret Merkezi, B Blok No: 5/1 06200 Yenimahalle / ANKARA - TURKEY

Web: [email protected]


Recommended