1”
1. Cut the automatic door bottom (ADB) to the size needed. Leave 1/16” (1.6 mm) clearance on each end.
2. Place the ADB on the door. All surface and semi-mortised units must be mounted on the push side of the door (side where the door stop is).
3. Fasten with screws provided. The adjusting brass nut must be on the hinge side and should not be adjusted until the unit has been mounted.
4. Optimum clearance between door bottom unit and floor or sill is 3/8” (9.5 mm). For model #369 clearance is 5/8” (15.9 mm).
5. Final adjustment to control the drop of the automatic door bottom can be made once the unit is installed, by turning the adjusting brass nut in or out. Open and close the door while adjusting the brass nut to get the desired seal with the floor or sill. Do not over adjust.
TRIMMING INSTRUCTIONS Trim from LOCK SIDE ONLY
Set screw
Maximum cut should NOT be closer than 1” (25.4 mm) to the set screw or 3.5" for models 367, 368, and 369.
Adjusting brass nut must be on HINGE SIDE
#8 x 1.500"(31.8)SMS.722"(18.3)
1.793"(45.5)
#8 x 1.500"(38.1) SMS
1.901"(48.3)
.916"(23.3)#8 x 1.500"(38.1) SMS#8 x 1.500"(38.1) SMS
1.901"(48.3)
.916"(23.3)
Steel Plate
Magnet
1.901"(48.3)
.916"(23.3)
Max. E�ective Drop.875"(22.2)
1.750"(44.5)
.719"(18.3)
1.750"(44.5)
1.00"(24.5)
Max. E�ective Drop.875"(22.2)
Max. E�ective Drop.875"(22.2)
.375"(9.5)
#351AA#351BK
#351D#351G
#361AA#361B#361D#361G
#365AA#365BK#365D#365FS#365G
#367AA#367BK#367D#367G
End Cap for #351End Cap for #361, #365, #367Surface-Mounted
Installation Instructions
Surface-Mounted Automatic Door Bottom With Watershed Option
L Note: #8361 Locking Key can’t be used with end caps.
2.81"(71.4)
0.94"(23.8)
#8361 Locking Key
#366A
#141A
OPTIONS
End CapFor #362, #366, #368installed with #141
Positive Pressure Tested Gasketing Materials For Fire Doors.For application to hollow metal type fire doors rated up to 3 hours, fiberglass or wood composite type fire doors rated up to 1-1/2 hours and wood type fire doors rated up to 20 minutes. Category J
.722"(18.3)
1.793"(45.5)
1.901"(48.3)
1.901"(48.3)
Steel Plate
Magnet
1.901"(48.3)
.916"(23.3).916"(23.3).916"(23.3)
1.750"(44.5)
.719"(18.3)
1.750"(44.5)
1.00"(24.5)#8x1.500"(38.1) SMS #8 x 1.500"(38.1) SMS#8 x1.500"(38.1) SMS #8 x 1.500"(38.1) SMS
Max. E�ective Drop.875"(22.2)
Max. E�ective Drop.875"(22.2) Max. E�ective Drop.875"(22.2)
.375"(9.5)
Semi-Mortised#352AA#352BK
#352D#352G
#362AA#362BK#362D#362G
#366AA#366BK#366D#366G
#368AA#368BK#368D#368G
End Cap for #352 End Cap for #362,# 366, #368
* Listing applicable for all models except #7350
#6x.750"(19.1) #6x.750"(19.1)
.705"(17.9)
.375"(9.5) 1.250"
(31.8)
Steel Plate
.371"(9.4)
1.575"(40.0)
.924"(23.5)
.371"(9.4)
1.575"(40.0)
Max. E�ective Drop.875"(22.2)
.924"(23.5)
.371"(9.4)
1.575"(40.0)
.924"(23.5)
1.250"(31.8)
2.250"(57.2)
1.50"(38.1)
1.750"(44.5)
1.50"(38.1)
1.498"(38.0) 1.378"
(35.0)
.595"(15.1)
#6x.750"(19.1) #6x.750"(19.1)Max. E�ective Drop
.875"(22.2)Max. E�ective Drop
.875"(22.2)
Magnet
Mortised #350AA #7350AA #364AA#364FS
End Cap for #350, #360, #364, #369
#360AA#320AA
End Cap for #320
#369AA
Suggested door cutout C\v" x 1>\zn"
Suggested door cutout 1" x 1B\,"
Suggested door cutout 1" x 1B\,"
Suggested door cutout 1" x 1B\,"
Suggested door cutout 11/16”x17/16”
Models 321, 323 Automatic Door Bottoms - Handed
.4375”
.598”
1.563”
1.969”
ø
End Caps for #321
(50.0)
(39.7)
(15.2)
Surface-Mounted
#321AAHanded
(L.H. shown)
.595"(15.1)
Neoprene
Zeroquiet seal
.062"(1.6)
Max. drop.750"(19.1)
#8 x 1.50”(38.1) TPHSMS
2.00"(50.8)
Mortised
#323AHanded (L.H. shown)
Max. drop.750"(19.1)
.595"(15.1)
Zeroquiet seal
Neoprene
.062"(1.6)
#6 x .750”(19.1) PPHSDS
1.458"(37.0)
.375"(9.5)
*
* Max. cut should not closer than 1” (25.4mm) to the set screw.
TRIMMING INSTRUCTIONS
After the unit has been mounted, thread the adjusting nut out until the seal contacts the floor/sill when the door is closed. Take care not to thread the adjusting too far out as that can damage the door bottom.
FINAL ADJUSTMENT
NOTE: Handing must be determined prior to trimming.
TO INSTALL:
1 Surface mounted unit must be mounted on the push side of the door stop (side where the door stop is).
2 The brass adjusting nut must be on the hinge side and should not be adjusted until the unit has been mounted.
3 Leave 1/16" (1.6) clearance on each end.
4 Optimum clearance between door bottom unit andfloor or sill is 3/8" (9.5).
Positive Pressure Tested Gasketing Materials For Fire Doors. For application to hollow metal type fire doors rated up to 3 hours, fiberglass or wood composite type fire doors rated up to 1-1/2 hours and wood type fire doors rated up to 20 minutes. Category J
4.25
5.500
FRONT
Additional Notes: Revision History Revision Description:D > Revised artwork
1. None A B C D E F
xxxxx 062679
MaterialWhite Paper
Edited By Approved By EC Number Release Date
J. Ellis M. Roberts 062679 03-27-19
Notes1. printed two sides2. printed black3. tolerance ± .134. printed in country may vary5. drawings not to scale
Title
Zero automatic door bottoms installation instructionCreation Datexx-xx-xx
Number
47255399Revision
DCreated ByX. XXXXX
Activity3899 Hancock Expwy
Security, CO 80911 © Allegion 2019Software: InDesign CS6
8.500
11.000
BEGINNING SHEET FOLDED SHEET
FRONT