June 10th, 2022
Members of the Siting CouncilConnecticut Siting Council10 Franklin SquareNew Britain, CT 06051
RE: Notice of Exempt Modification123 Palmer Road, Chaplin, CT 06235Latitude: 41.784528Longitude: -72.135694T-Mobile Site#: CT11508F - Anchor
Dear Ms. Bachman:
T-Mobile currently maintains six (6) antennas at the 117-foot level of the existing 146-foot monopole tower at123 Palmer Road in Chaplin, CT. The 146-foot monopole tower is owned and operated by American Tower.The property is owned by the Janet Bessette Revocable Living Trust. T-Mobile now intends to remove andreplace (3) antennas and add (3) antennas at the 117-foot level of the tower. These antennas will support 5Gservices.
Planned Modifications:Tower:Install New:(3) Ericsson AIR 6419 B41 Antennas(3) Commscope VV-65A-R1 Antennas(3) Radio 4460 B25 B66(2) 1.99” Hybrid Cables
To Be Removed:(3) APX18 Antennas(3) Radio 4415s(3) KRY 112 489/2 TMAs(3) KRY 112 144/2 TMAs(12) 1 ⅝” Coax
Ground:Install (1) 6160 Power Enclosure, and (1) B160 Battery Rack. Remove (6) RUS02 and (3) Diplexeres.
This facility was originally approved by the Council in Docket No. 211 on February 14, 2002. This modificationwill not break any of the conditions set forth in this approval.
Please accept this letter as notification pursuant to Regulations of Connecticut State Agencies§ 16- SOj-73, forconstruction that constitutes an exempt modification pursuant to R.C.S.A. § 16-50j-72(b)(2). In accordancewith R.C.SA. § 16-SOj-73, a copy of this letter is being sent to First Selectman Juan Roman III, Elected Official,and Jay Gigliotti, Zoning Enforcement Officer, as well as the tower and property owner.
The planned modifications to the facility fall squarely within those activities explicitly provided for inR.C.S;A. § 16-50j-72(b)(2).
1. The proposed modifications will not result in an increase in the height of the existing structure.
2. The proposed modifications will not require the extension of the site boundary.
3. The proposed modifications will not increase noise levels at the facility by six decibels or more, or to levelsthat exceed state and local criteria.
4. The operation of the replacement antennas will not increase radio frequency emissions at the facility to alevel at or above the Federal Communications Commission safety standard.
5. The proposed modifications will not cause a change or alteration in the physical or environmentalcharacteristics of the site.
6. The existing structure and its foundation can support the proposed loading.
For the foregoing reasons, T-Mobile respectfully submits that the proposed modifications to the abovereferenced telecommunications facility constitute an exempt modification underR.C.S.A. § 16-50j-72(b)(2).
Sincerely,
Eric BreunTranscend WirelessCell: 201-658-7728Email: [email protected]
Attachmentscc: Juan Roman III - First Selectman of ChaplinJay Gigliotti - Zoning Enforcement OfficerEverest Infrastructure Partners - Tower OwnerFrontier Communications - Property Owner
10 0 28 242 0
15 0 .0 1
20 0
20 0200
200
200
200
200
150
300
223.34
330
204
154111
268
19 3 .6 6 20 0 .2 8
36 5 .5 0
60 0
50
31 0
25 5
20 5
23 1 .3 5
21 0
11 6
21 0
21621285
357
488
206.72
206.72
548
92
22 5
27 7
20 0
20 0
20 0
20 0
27 2
31 8
222740 326 35023 024 524 7
200
249.73
578
220
245
15 0 .3 315 0
40 6 .0 222 0 .8 5
299
757
10 037 0
32 0
33 525 0
13 615 0 50 0 50 15 6 .5 5 30 0 11 8
311 25
91 510 0 25 7 22 5 16 4 21 6 .1 6
25 0
11 3 2
18 8.9
50 4.4 4
339.6
815
015
025
215
108
160
13 6
17 5
22 0
26 4
52
21 020 520 020 020 020 027 121 036 921 025 037 3
264
200
200
200
87
50 .8 8
154.55
71 0
69 0
53 9.2
13 0
561.8
212 .2
925
2 .3
209 .7
725
9 .04
150
150
351
7313 8
75 4
270
208
208
208
45 0
20 0
38 6539515 021 320 020 119 920 0606020 945 821 750
28 0
20 028 5
200
200
200200
200234.6
244.36
298
8 9 42
4 0 1 .8 5
2 2 5 .5
46
424
2 3 4
2 5 4
651
445
200
102
308±
170
200
150
275 0
1501 90
2 3 0
200
200
225
708
212
400
2 5 5
210307
2 05
202
317
403390
736
858
57
954
412
215216
192
329
241.7318
290.2
228 72
322155
155
109200
207
884
25 4 200 200
110100
40
160.3
111 .5 25
168
474
150
311
20 016 95652 010 04022 927 9
25 6
40 2 .8 4
20 0
58 0 .8 4
5021 0
42 8 .8 7
35 3 .2 2
79 .3 5
19 7.2 1
87 .4 723 7 .8 3
220
36 9323 9
20 5
21 0
21 0
21 0
20 6
24 0
31 5
20 415 0
33 924
3
23 .5 8 81 .3 5 10 0 .6 1 10 0 .6 124 3 .3 8
40 5 .6 7
446.84
10 0
23 4
234.11
10 342 0
210
450.96
20 0199.28
199.28
199.34
360.15
35 0
237.98
300.66
16 4 .7 1199.34
19 3 .3 8
199.34
267.67
37 6 .5
38 6 .3 5
111 4 .13
13 2 6 .6 1
13 3 7 .0 9
13 5 4 .1 7
32 430032 432 6 .8 9275.88
42 0 .3 3
26 7 .3
45 1 .7 3
80
198.62
62 7
34 1
70
18 6
20 0
89
25 5
27 4
14 0250
30 0
61 6
11 3 9
59
14 010 2
17 6
12557
151
22 9228
22 9
21 8
232.5
207.5
47 1 .1 3
72 6 .6 9
26 0 50 13 4
168
192
17095152151
291440
20 0
20 0
440
440
440
440
20 0
14 0
22 5 270
170
170
270
108176.14
120.13
390
35 8 .1 4
450
212.43
462.1
49 0 .6 9
67 3 .4 9
25 0 20 0452.45
449.78
440.84
15 1 .6 5
170.4
165.31
510 .4 632 5 .5 4
34 5 .5 5
750
1011.57
31 9 .9 6
352 .11
260 .28529.9
40
28 0
492.8
336.57
167.15
718.48
385.6394
300
300
31 0 300
654
335
25 8
372
865
470
180.12
701.42
25 2 .0 1
443.21
489.22
21 0420
43 4 .4 4
411 .9 8
540.96
18022 5
58
17 5 .8 3
24 1 31924 7
27 9
128
31229 6
294
87
16 1
17 0 170
204.09
301.56
436.17
250
595
114.98
748 135.25
14 0
82 8
31 9
21 9
99 .0
99 .0
107
10 7
23638 4 .5
150
150 100
36516 1
16 650
30
180
27 4
245
315
127
76 69.0
21725 0 270
27015 0
242
629.0
154
7015 6 .5 5
560
56 0
294
698
89 .011 8
329
366
36 1
23 2
35 6
927
37 5
200.31
67 1 .1 2
200
28 4
23 0
7121
0
30 222 2 54 .0 3
21 0
255
12 6
32531 9 .3 4
19 5 .1 4
12 6
12 5.0 6
49.7 7
775
775
22 5 19 0 .3 3
250
30 .2 5
59 .5 5
196.2
7
28 0 .5 6
24 6
70 0
44 4
43 2.6 3
12 7 .8 3 68 .030 .4 6
74 .2 2
11 8 .9 2
53.76
227 6
108 .9
416
9 .272
9 .15
258 .1
8
31 2 .4 3 14 7 .1 6
373 .0
2
26 8.7 4
18 1 .5
91 .9 9
261.6
13 1 .7
30 7 .6 3
408 .1
4
52 6 .0 7
65 9 .0 1 29 0
150
29 0
29 0
51 9
15 7.1 7
48 4.2 1
415 .6
5
28 7
59
203
29 3
30 0
12424 5
14 3
12 1
35 5
50
37 5
27 7
554
32 4
44 7
234
43 4
29 5
125
36 012 0
24 2
15 6
500
20 0
12 9 9
16 220 0
451
45 146 0
46 0
44 0
44 044 0
20 020 0
660
42 0
663
20 0
11 518 0
402
62 4
21 0 2
67 0
222
42 2
180
64
74 8
382
38 4
242
258
33 8
33 6
32 3
44 7
200
44 4
44 4
200
44 7
200
37 0
248.76
15 8
14 7
20 3
10 4
34 3
29 9 24 6 .8
259.2
28 0
30 0 32 5
33 6
18 5
41 2
45 2
30 2 .9 545 2 .8
20 2 .3
86.55
14 5 .1 7 56 7.2
15 7.3 5
14 5
561.8
14 6 .8 5
17 7 .2 4 10 0 24 0 .1 3
22 6 .1 6
181.18
152.45
25 6 .5 8
354 .7
6
83 .7 7
19 7.2 8
11 082 .8 317 5 .8 8
333.2 8
60 .1 5 13 1 .6 3
11 015 1 .0 3
15 0 .0 4
190 .2
3
35 8.7 1
34 3.4 423 2
.0 6
27 4 .0 6
17 0 .0 311 7 .8 2
11 2 .1 916 5 .2 4
119
15 023 1
84 3
83 3
90 9
31 2
260
311
203
30 1
31 2
208
208
31 224 316 5
36 7
31 9 20 5
23 2
34
64 2400
42 1
21 6
1867
1471
627
27 1211
60
667
1515
1527
42 0
20 4
310
117
55 0
39 8
237
19 9
434
43 9
20 0
440.1
44 0 .1
44 0 44 0
20 0 34 99
600 59 3
21 5 50
311
356
17 090
301
15 095
751
28 0
26 7
281
14 8
462
41 7
273
53
85
76
10 3
906 .93
9 0 7 .1 2
102
9 8 2 .2 6
9 9
325328.73 9 5 .2
294.1
257.2
2 6 7 .5
233223
272
718
9 67
807
427
684
118
2 0 9
117
1112
443
6 12
427
199
2 7 2
76 2 00
2 0 0
150
316
167
2 3 9
308
1 901 9 0150
200
4 01 9 4
1 5 4 200
1 4 1 1 4 5
351
199
260
324
1090
1170
3 7 0
190160
3 6 3
238
2 3 4
190
1 9 0
239
3 93
780
220
671891
2 9 1
242
5 4 6
37 5 0
75
1 4 3
173172 .89
2 1 2
4 5 1 .9 1
335.48
6 5 8 .9
510
6 6 0423±
641±
660
268
7 8
265 187
188
1 2 8 5 2 0 150
4 7 3
80
4 6 6
172 323
4 8 2 58
360
180
195
174
154
1 80
84 3 6 4
210
184187
3 6 5
135
564
36222
2 9 6570
310
385
16850
6 6
2 3 8
145
442
492
150
5 2 1
3 0 02 3 3
6 4 1
1263
96.0
1870
140 67
538
325
225
367
224 353
388
100
446
366
220
203
292
76
129 0
310
1550
1280.63
246 .06
464.84
264.45
492
172
506
396
306
208
416 104
150
746
27 7
446 303
214455
202
595
411
608
146
423
332
565
779
21521
217200
207
804
780
782
445
329
22
61
301
250
250
250
200 200
251 .7750
227.29
310 .97
479 .8 8
457 .87
132 .3534.3 4
200 .8890.6 8 100 .57
318.6
315
50
205 110
125
110
128
43225
189.2
374
59216
184
232
150
8 0 4
718
15 020 3
139
60
100
36 0
37 034 8
10 6
44 4 .9
23 7
10 0
285
20 0
10 0
20 0
230
55 0
80
24 038 4
860
29 0 11 0
25 4
22 4
718
364176
12 8
12 1 .0 6
93.5
10 7 .5 7 57 .2 412 5 .4 5
30 0
140 22 1
311
17 8
32 1
179
192
20 055 052 2
10 2
373
46 5
99 7
172
16 9
221
225
22 6
548
62 5
40 7.5 2
384230
53 8
35 7 .9 8
26 0 .2 4
14 9 .5
44 0
76 9 .1 8
15 8 .4 3
16 0
35 1 .8 7
11 026 2 .3 1
70
65 0
77 6 .9 9
12 9 .0 79013 4 .3 9
58 9 .0 8
42 0 .2 8
40 .6 2
37 5 .9 1
23 7 .3 8
23 9 .9 6
21 0
23 9 .9 6
65 .4 317 9 .1 9 17 9 .4 6
13 3 .2 4
10 0
56 4
17 0
275
250
50 1
33 0
22 0
34 2
440
29 4 67 7
29 3
69 6 .0
18 0
18 0
18 5
18 3
17 4
22 4
73 2
76 9
77 4
69 9 .0
21 7
15 0 260
43 1
50 8
35 020 755 4 43
2
55 0
44020 0
837
239.46
483.84
160.21
170.36287 .6 0
24 7 .2 514 2 .0 9
32 2 .1 5
212.04
767.79
474.77
73.5799.62
66.5793.39
94.61173.09
34 9 .3 214 5 .11
13 8 .4 173 .3 6
54 .7 4
22 4 .1 6
90 .5 530 .7 9
23 3 .5 9
147 .2 3
50
275
47 7.7 7
266 .9 5
285 .4
1
122 .4
5
568 .9
555
0 .64
719.0
4
24 4 .1 0 20 8 .4 4 16 8 .7 3 43 5 .4 0
70 .6 2 13 2 .9 1 20 5 .3 9 58
17 8 .7 4
38 .1 9
74.5 9
101 .3
917
9.10
11 7.8 1
47 3.1 7
Ross Rd
Linkkila LnMansfield
MansfieldMansfield
#125
#48
#122
#123
#360
#41
#49
#90 #31
#108
#111
#75
#222
#164
#288
#87
#240
#20
#63
#124
#176
#179
#120
#88
#101
#12
#8
#156
#171
#128
#66
#18
#57#203
#166
#278
#176
#26
#5
#232
#45
#146
#278
#21
#41
#51
#138
#112
#167
#67
#9
#20
#188#41
#69
#39
#8
#119
#17
#318
#75
#187
#195
#12
#184
#29
#56
#49
#119
#203
#11
#97
#41
#93
#21
#82
#137
#6
#117 & 95
#222
#18
#23
#47
#147
#68
#54
#18
#149
#100 #4
#175
#85
#241
#84
#15
#49
#109
#55
#188
#150
#193
#242
#50
#55
#63
#196
#19
#12#177
#171
#273
#5
#111
#93
#21
#65
#342
#13
#275
#192
#151
#263
#114
#32
#235
#69
#239
#171
#85
#150
#156
#304
#27
#189
#101
#69
#122
#109
#92
#211
#24
#80
#340
#92
#287
#35
#106
#250
#97
#45
#110
#322
#93
#99
#106 #78
#63
#251
#64
#20
#202
#26+30
#76
#27
#5
#280
#268
#150
#216
#58#66
#298
#28
#195
#80
#82
#216
#50
#323
#91
#168
#73
#25
#83
#215
#281
#315
#304
#74
#116
#311
#140
#212
#34
#139
#61
#149
#171
#160
#117
#28
#64
#85
#245
#13
#98
#9
#109
#9
#129
#144
#145
#134 #325
#121
#161
#10
#219
#147
#122
#209
#182
#179
#292
#161
#120
#251
#210
#204
#267
#259
#201
#181
#207
#186#239
#152
#153
#36
#330
#241
#129#310
#140
#85
#334
#135
#3
#22
#60
#28
#135
#133
#315
#22
#19
#170
#200
#16
#39 #29
#290
#376
#179
#51
#301
#184
#50
#295
#303
#18
#123
#42
#225
#262
#200
#187
#219
#214
#284
#47 #44
#260
#310
#256
#96
#184
#288
#12
#109
#36
#262
#114
#267
#43
#264
#258
#159
#31
#222
#244 #234
#223
#35
#2
#54
#350
#227#221
#203
#177
#144
#77
#106
#190
#405
#176
#57
#11
#46
#96
Stonehouse Brk
Natchaug RivNatchaug Riv
Natchau
g Riv
St onehouseBrk
Stonehouse Brk
Tu rne r B rk
Na tchaug R iv
Bu ttonball B rk
Turner Brk
Stonehouse Brk
Federal Rd
N Bedlam Rd
Miller Rd
Phoe
n ixv il l
e Rd
Palmer Rd
Bedlam Rd
S Bear Hill Rd
Ridge Rd
Canada Ln
England Rd
York Rd
Dianas Pool Rd
S Bear Hill Rd
S Bear Hill Rd
Palme
r Rd
Pa lm er R d
Ridge Rd
Phoe
n ixv il l
e Rd
P hoen
ix vil le
R d
S Bear H ill Rd
Cross Rd
Bedlam Rd
N Bedlam RdS Bedlam Rd
N Bedlam Rd
Palmer Rd
Bedlam Rd
Bedlam Rd
Davis Rd
Chaplin St
Palmer Rd
England Rd
Phoenixville Rd
Pa lmer Rd
Hall R
d
Mountain Laurel Ln
Davis Rd
Feder
al Rd
N Bedlam Rd
S Bedl
am Rd
Canada
Ln
Davis Rd
Miller Rd
55-37
55-32
55-54
55-34-1
55-57
55-27
55-42
55-48-2
55-3
55-61-2
55-41
55-7
55-3
55-8
55-53-8
55-49
55-61
55-53-6
55-13
55-49-1
55-3-2
55-5055-15
55-54-8
55-57-1
55-34
55-31
55-52
55-4755-14
55-56
55-14-1
55-56-1
55-24
55-36
55-44
55-24-2
55-54-2
55-9
55-30
55-27-A
55-3555-33
55-51-1
55-38
55-58
55-24-1
55-53-9
55-48-1
55-10
55-40
55-11
55-53-5
55-8-3
55-63
55-2
55-44-2
55-47-3
55-62
55-16
55-6
55-43
55-53-7
55-46
55-20
55-4
55-44-3
55-5555-12
55-54-5
55-60
55-44-1
55-48-3
55-39
55-17
55-61-1
55-62-1
55-47-1
55-54-3
55-26-1
55-54-6
55-19
55-47-4
55-61-3
55-18
55-47-2
55-53-3
55-51-2
55-53-1
55-53-2
55-53-4
55-8-1
55-54-4
55-48-4
55-55-2
55-25
55-54-1
55-26
55-23-155-8-5
55-8-2
55-20-2
55-8-7
55-8-6
55-23
55-45
55-20-1
55-8-8
55-59
55-29-155-1
55-22
55-28
55-5
55-30-1
55-29
!
55-21
!
55-50-1
!
55-43-1
!
55-12-1
82.13 AC
10.23 AC
9 AC
21 AC
42.75 AC 68.04 AC
2 AC
4 AC
26.5 AC
21.3 AC
12 AC
31.35 AC
18.5 AC
5 AC
5 AC
10 AC
25.5 AC
3 AC
9.5 AC
3 AC
3 AC10.4 AC
25.5 AC
6.5 AC
2 AC7.9 AC
2 AC 2 AC
2 AC
2 AC
2 AC
5.7 AC
2 AC
15.29 AC2 AC
3.7 AC
2 AC
11.25 AC
10.05 AC
2 AC
3.9 AC
5.47 AC
2.9 AC
10.66 AC
3.7 AC3.6 AC
2.83 AC
4.22 AC
1 AC
3.53 AC
2.9 AC
3.92 AC
8.9 AC 2.9 AC
7.16 AC
1 AC
3.02 AC
1 AC
3.37 AC
6.41 AC
2.1 AC
8.4 AC
1.7 AC
3.67 AC
4.41 AC
2.55 AC4.71 AC
2.38 AC
1.8 AC
1.6 AC
4.01 AC
1.7 AC
2.02 AC
2.23 AC
1.5 AC
4.31 AC
4.01 AC
2.07 AC1.5 AC
1.3 AC
2.03 AC
2.03 AC
3.01 AC1.98 AC
2.02 AC2.13 AC
1.75 AC
1.4 AC
2.13 AC
1.1 AC
1.57 AC
1.2 AC
2.61 AC
3.06 AC
2.56 AC
36.05 AC
1.33 AC
1.1 AC
2.29 AC
1.5 AC
2.31 AC
1.17 AC
1.3 AC
1.23 AC
2.29 AC
2.04 AC
2.04 AC
2.04 AC
0.6 AC
2.08 AC
2.04 AC
0.5 AC
0.55 AC
0.4 AC
0.7 AC
0.2 AC
0.49 AC
0.06 AC 0.01 AC
75 -66
57 -26 -2
75 -43
89 -30
57 -30
53 -29
53 -40
73 -34
73 -46
89 -23
71 -2
75 -44
57 -35
53 -80
57 -10
57 -26
73 -60
57 -36
53 -1-3
57 -29
57 -32
53 -90
73 -50 -1
53 -26
53 -76 -1
57 -36 -1
73 -1
53 -59
53 -28
73 -3873 -49
73 -2
53 -67
57 -24
91 -25 -2
57 -1
53 -76
91 -148
57 -37
53 -57 -1
91 -145
53 -27
91 -137 -4
91 -137 -3
57 -2
53 -58
53 -28 -1
57 -34
53 -25
57 -23
53 -67 -3
53 -37
73 -6
57 -39
91 -137 -1
53 -36
53 -35
53 -34
91 -137
75 -11
73 -4-1
57 -23 -1
53 -6
57 -37 -3
57 -27 -1
57 -28
91 -140
53 -33
73 -45 -5
53 -74
53 -24
73 -5-2
73 -3
73 -7
73 -4
91 -155
57 -29 -1
91 -126
53 -51
73 -45
53 -54
53 -50
73 -5-3
57 -30 -2
57 -37 -2
57 -30 -1
53 -67 -2
57 -21 -5
57 -21 -7
57 -8
53 -59 -1
53 -26 -2
53 -14
53 -44
93 -16 -4
57 -3853 -52
57 -28 -1
53 -32
91 -150 -4
57 -21 -6
53 -30 -2
75 -40 -1
75 -39
89 -25
57 -1153 -63 -1
71 -3
91 -147
91 -141
73 -5-1
53 -24 -1
53 -5
53 -48
73 -50
73 -47
57 -5-1
53 -21
93 -16 -1
53 -1
53 -76 -2
57 -21 -4
91 -144
53 -8
53 -4
53 -9
53 -20
53 -7
53 -30 -4
53 -68
91 -150 -1
57 -27
53 -18
57 -15
75 -37
91 -147 -1 91 -131
57 -21 -3 93 -16 -14
53 -30 -1
53 -60
57 -12
53 -12
89 -23
53 -38
93 -16 -11
57 -18
57 -21 -2
75 -1273 -35
93 -16 -2
73 -50 -2
53 -17
93 -16 -16
93 -16 -12
53 -11
91 -139 -1
53 -70
53 -57
53 -77
53 -23
53 -39
57 -21 -1
71 -1
75 -1
93 -16 -3
53 -1553 -19
73 -46 -1
53 -13
53 -3
53 -16
53 -17 -1
73 -7-1
93 -16 -13
93 -16 -5
53 -66
93 -16 -15
73 -47 -1
53 -47
57 -26 -3 53 -31
53 -28 -4
57 -37 -1
75 -28
91 -130
53 -53
53 -46
57 -26 -4
75 -29
57 -36 -2
73 -48
93 -16 -10
91 -137 -2
75 -40
91 -137 -5
53 -28 -2
91 -150 -2
53 -30 -3
53 -45
53 -40 -1
57 -41
53 -30 -5
75 -9
53 -59 -2
57 -24 -4
57 -4057 -14
53 -26 -1
57 -13
57 -24 -3
57 -24 -5
57 -25
93 -16 -9
73 -45 -4
53 -62 -1
57 -9
57 -7
53 -71
75 -7
53 -65
53 -26 -3
57 -6
57 -22
53 -72
53 -43
91 -27
53 -67 -3A
53-42
93 -78
75 -43 -2
53 -81 -3
53 -20 -1
53 -79
53 -22
75 -38
75 -4
91 -131 -1
73 -36 73 -37
53 -20 -2
75 -32
91 -137 -A
75 -5
57 -37 -4
57 -4
91 -146
91 -143
91 -151
75 -8-1
53 -6453 -55
75 -2
91 -129
73 -44 -2
57 -24 -1
91 -133
93 -16
91 -136
75 -34
57 -26 -1
91 -138
73 -44 -1
75 -36
57 -19
75 -8
53 -10
57 -31
91 -14991 -150 -3
57 -33
57 -3
53 -7553 -73
75 -33
53 -41
53 -70 -1
91 -142
57 -16
57 -44
75 -42
53 -18 -1
53 -61
73 -44
53 -62
75 -6
75 -35
53 -2
91 -128
75 -10
57 -24 -2
93 -15
75 -31
57 -5
53 -69
91 -153
57 -43
73 -43
53 -81 -4
93 -16 -6
53 -67 -4
91 -152
57 -42
75 -30
53 -83
75 -41
91 -149 -1
73 -45 -173 -45 -3
91 -160
91 -127
75 -3
53 -89
M A P N O .
55100 0 100 200 30050M E TE R S
400 0 400 800 1,200200FE E T
R EV ISED TO :
TH IS M A P IS FO R A S S E S SM E N T P U R P O S E S . IT IS N O T VA LID FO R L E G A L D E SC R IP T IO N O R C O N V EYA N C E .
TH E H O R IZ O N TA L D ATU M IS T H E C O N N E C TIC U T S TAT E P L AN EC O O R D IN ATE SY S T E M , N A D 8 3.
OC TO B ER 1, 2021
PR O P E RTY M AP S
C H APLINC O N N E C TIC U T
SC ALE : 1" = 400 'LEGENDPA R C EL AR E A 5.1 ACD IM EN SIO N 365SC ALED D IM EN S IO N 100±
EASE M EN T
TO W N L IN E
STR E AM
IN TE R M ITT EN T S TR EA M
C O N D O M IN IU M
W ATER BO D YC O M M O N O W N E R SH IP
IN D E X D IA G R A M
55
02
4 6 8
515557
71 7375
77
89 91 93
53 ³11 P leasant S tree t, Littleton , N H 03561800.322.4540 - w w w.ca i-tech .com
R E V I S E D A N D R E P R I N T E D B Y
Other ID: 55-54
CURRENT OWNER TOPO. UTILITIES STRT./ROAD LOCATION CURRENT ASSESSMENTDescription Code Appraised Value Assessed Value
SUPPLEMENTAL DATA
RES LAND 1-1 25,300 17,700
Total 25,300 17,700
CHAPLIN, CT6024
BESSETTE JANET L REVOCABLE LIVING TRUST
5 VICTORY LN
WILLIMANTIC, CT 06226Additional Owners:
VISIONGIS ID:
BK-VOL/PAGE SALE DATE q/u v/i SALE PRICE V.C. PREVIOUS ASSESSMENTS (HISTORY)102/ 97187/ 97660/ 633
10/03/201601/09/200701/25/1996
UU
VVV
000
010600
EXEMPTIONS OTHER ASSESSMENTS This signature acknowledges a visit by a Data Collector or AssessorYear Description Amount Code Description Number Amount Comm. Int.
APPRAISED VALUE SUMMARY
NOTES
Net Total Appraised Parcel Value 25,300
000
25,3000
25,300
Appraised Bldg. Value (Card)
RECORD OF OWNERSHIP
2015-ADJ ACREAGE PER SURVEY MAPVOL 12 PG 14
BESSETTE JANET L REVOCABLE LIVING TRUSTBESSETTE JANET L
2016-REMOVED COMMERICAL LAND
LESSEE RESPONSIBLE
CELL TOWER LAND LEASE VALUE= 1500 X 12=
18,000-(10% EXP)=16,200/.09 CAP= 180,000
C
BUILDING PERMIT RECORDPermit ID Issue Date Type Description Amount Insp. Date % Comp. Date Comp. Comments Date ID Cd. Purpose/Result18-67E18-54E
10/26/201810/09/2018
ELEL
ElectricElectric
13,50020,000
00
GENERATORANTENNAS REPL
04/24/201802/16/2016
JWAO
4145
Change - Field ReviewChange - Value Change Town
LAND LINE VALUATION SECTION
Census Tr.Survey #
DV Map #Call Back
DV Lot #
X
Appraised XF (B) Value (Bldg)Appraised OB (L) Value (Bldg)Appraised Land Value (Bldg)Special Land Value
Total Appraised Parcel ValueValuation Method:
Total:ASSESSING NEIGHBORHOOD
Type ISVISIT/ CHANGE HISTORY
ASSOC PID#
Adjustment: 0
Type
Yr. Code Assessed Value Yr. Code Assessed Value Yr. Code Assessed Value1-1 22,900 2012 6-2 8,400 2008
20082008
1-11-15-2
159,000104,900
45,900
Total: 22,900 Total: Total:
2017
NBHD/ SUB0001/A
NBHD Name Street Index Name Tracing Batch
8,400 309,800
B#11
Total Card Land Units:
100100
Use Code
UseDescription
Resid VacantResid Vacant
Zone D Front Depth2.008.23
UnitsACAC
AC10.23 Parcel Total Land Area:
3,100.003,100.00
1.00001.0000
I.Factor
Unit Price S.A.
00
10.23 AC
1.00001.0000
AcreAcre
C.Factor
1.000.75
ST.Idx Adj.
0.000.00
Total Land Value:
TOPO
Notes- AdjSpecial Pricing
Adj. Unit Price Land Value6,200
19,100
25,300
DiscDisc
Property Location: 123 PALMER RD MAP ID: 55/ 54/ / /Bldg #: 1 of 1 Card 1 of 1 Print Date: 12/11/2018 12:41Vision ID: 622 Account #
Parcel DescriptionB000626
Bldg Name: State Use: 100Sec #: 1 ofof 1
S AdjFact
1.001.00
Spec Use Spec Calc
No Photo On Record
Model
CONSTRUCTION DETAILElement Cd. Ch. Description
COST/MARKET VALUATION
BUILDING SUB-AREA SUMMARY SECTIONCode
Ttl. Gross Liv/Lease Area:
OB-OUTBUILDING & YARD ITEMS(L) / XF-BUILDING EXTRA FEATURES(B)
00 Vacant
MIXED USE
Element Cd. Ch. DescriptionCONSTRUCTION DETAIL (CONTINUED)
Property Location: 123 PALMER RD MAP ID: 55/ 54/ / /Bldg #: 1 of 1 Card 1 of 1 Print Date: 12/11/2018 12:41Vision ID: 622 Account #
Parcel DescriptionB000626
Bldg Name: State Use: 100Sec #: 1 ofof 1
Code100
DescriptionResid Vacant
Percentage100
Description Living Area Gross Area
0 0
Eff. Area Unit Cost Undeprec. Value
Adj. Base Rate: 0.00
AYB
Dep CodeRemodel RatingYear RemodeledDep %Functional ObslncExternal ObslncCost Trend FactorCondition% CompleteOverall % CondApprais ValDep % OvrDep Ovr CommentMisc Imp OvrMisc Imp Ovr CommentCost to Cure OvrCost to Cure Ovr Comment
0
0
0
Code SubDescription Sub Descript L/B Units Unit Price Yr Gde Dp Rt Cnd %Cnd Apr Value
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
G-001
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
TITLE SHEET
0 FOR CONSTRUCTION ADE 06/02/22
0
LOCATION MAPVICINITY MAP
Know what's below. Call before you dig.
R
COMPLIANCE CODE PROJECT SUMMARY PROJECT DESCRIPTION
UTILITY COMPANIES
SHEET INDEXSHEET
NO: DESCRIPTION: REV: DATE: BY:
G-001 TITLE SHEET 0 06/02/22 ADE
G-002 GENERAL NOTES 0 06/02/22 ADE
C-101 DETAILED SITE PLAN 0 06/02/22 ADE
C-102 DETAILED GROUND PLAN 0 06/02/22 ADE
C-201 TOWER ELEVATION 0 06/02/22 ADE
C-401 ANTENNA INFORMATION & SCHEDULE 0 06/02/22 ADE
C-501 CONSTRUCTION DETAILS 0 06/02/22 ADE
E-501 GROUNDING DETAILS 0 06/02/22 ADE
R-601 SUPPLEMENTAL
R-602 SUPPLEMENTAL
R-603 SUPPLEMENTAL
R-604 SUPPLEMENTAL
R-605 SUPPLEMENTAL
R-606 SUPPLEMENTAL
R-607 SUPPLEMENTAL
MOUNT MODIFICATION SHEETS
SITE LOCATION
SITE ADDRESS:
123 PALMER ROAD
CHAPLIN, CT 06235-2416
COUNTY: WINDHAM
GEOGRAPHIC COORDINATES:
LATITUDE: 41.784528
LONGITUDE: -72.135694
GROUND ELEVATION: 504' AMSL
ATC SITE NAME: CT CHAPLIN SOUTH CTATC SITE NUMBER: 411216T-MOBILE SITE NAME: CT508//VERIZON CHAPLINT-MOBILE SITE NUMBER: CT11508FSITE ADDRESS: 123 PALMER ROAD
CHAPLIN, CT 06235-2416
PROJECT TEAM
TOWER OWNER:
AMERICAN TOWER10 PRESIDENTIAL WAY
WOBURN, MA 01801
PROPERTY OWNER:
JANET L BESSETTE123 PALMER ROAD CHAPLIN, CT 06235
ENGINEER:
POWER OF DESIGN GROUP, LLC11490 BLUEGRASS PKWY
LOUISVILLE, KY 40299
POWER COMPANY: NORTHEAST UTILITY SERVICESPHONE: (800) 592-2000
TELEPHONE COMPANY: UNKNOWNPHONE:UNKNOWN
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
PROJECT LOCATION DIRECTIONS91N-WILBUR CROSS HWY CT-15 VIA EXIT 29 TOWARDS I-84/E
HARTFORD/BOSTON. CT -15N/WILBUR CROSS HWY BECOMESUS-6E/I-84/WILBUR CROSS HWY 1.6 MI/MERGE ONTO I-384 E VIA EXIT59 TOWARD PROVIDENCE 8.5 MI/TURN SLIGHT LT ONTO US-6/CT-66.CONTINUE TO FOLLOW US-6 E9.2 MI. TURNLT ONTO PHOENIXVILLERD/CT-198 1.2 MI/TURN LT ON RIDGE RD. TURN LT ON PALMER RD.SITE IS THE SECOND DRIVEWAY ON THE LT AFTER WHITE HOUSEMAILBOX #119. GATE COMBO 4667. T1'S MOUNTED IN OUTDOOR
HOFFMAN BOX
1. THE FACILITY IS UNMANNED.2. A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE
A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE.3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND
DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE.4. NO SANITARY SEWER, POTABLE WATER OR TRASH
DISPOSAL IS REQUIRED.5. HANDICAP ACCESS IS NOT REQUIRED.6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS
AN ELIGIBLE FACILITIES REQUEST ENTITLES TOEXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS AMODIFICATION OF AN EXISTING WIRELESS TOWER THATINVOLVES THE COLLOCATION REMOVAL AND/ORREPLACEMENT OF TRANSMISSION EQUIPMENT THAT ISNOT SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (B)(7).
PROJECT NOTES
THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASEDAND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW:
REMOVE (3) ANTENNA(s), (3) RRU(s), (6) TMA(s), AND (12) COAXCABLE(s)
INSTALL (6) ANTENNA(s), (3) RRU(s), (2) HYBRID CABLE(s) ANDMOUNT MODIFICATIONS
EXISTING (3) ANTENNA(s), (3) RRU(s), AND (1) HYBRID CABLE(s) TOREMAIN
GROUND WORK:
EXISTING (1) RBS 6201 ODE CABINET, (2) BB 6630, AND (1) DUG20 TOREMAIN
INSTALL (1) ERICSSON 6160 CABINET, (1) B160 CABINET, (2) RP 6651,(1) PSU 4813 vR4A VOLTAGE BOOSTER, (1) CSR IXRE V2 ROUTERAND POWER CONDUIT FROM EXISTING PPC TO PROPOSED 6160CABINET
REMOVE (6) RUS02 B2 AND (3) DIPLEXERS
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLEDIN ACCORDANCE WITH THE CURRENT EDITIONS OF THEFOLLOWING CODES AS ADOPTED BY THE LOCALGOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS ISTO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TOTHESE CODES.
1. 2018 CT STATE BUILDING CODE/ 2015 IBCW/ CT AMENDMENTS
2. 2018 CT STATE BUILDING CODE/ 2017 NECW/ CT AMENDMENTS
3. LOCAL BUILDING CODE4. CITY/COUNTY ORDINANCES
APPLICANT:
T-MOBILE4 SYLVAN WAY
PARSIPPANY, NJ 07054
T-MOBILE ANCHOR AMENDMENT PLAN67D5D998E ODE+6160 CONFIGURATION
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
G-002
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
GENERAL NOTES
0 FOR CONSTRUCTION ADE 06/02/22
0
GENERAL CONSTRUCTION NOTES:1. OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THE
CONTRACTOR WILL INSTALL
A. BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUNDBUILD/CO-LOCATE ONLY)
B. AC/TELCO INTERFACE BOX (PPC)C. ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC
TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION)D. TOWERS, MONOPOLESE. TOWER LIGHTINGF. GENERATORS & LIQUID PROPANE TANKG. ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTINGH. ANTENNAS (INSTALLED BY OTHERS)I. TRANSMISSION LINEJ. TRANSMISSION LINE JUMPERSK. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITSL. TRANSMISSION LINE GROUND KITSM. HANGERSN. HOISTING GRIPSO. BTS EQUIPMENT
2. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THECOMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCHMATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FOR PLATFORM,ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES,COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS ANDDISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER,CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS ANDRUBBER MATTING, REBAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS,MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES ANDALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TOTHE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FORPERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIREDPERMITS.
3. ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCALCODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTIONSPECIFICATIONS.
4. CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUNDUTILITIES PRIOR TO START OF CONSTRUCTION.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIREDINSPECTIONS.
6. ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, ANDSITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALLDISCREPANCIES REPORTED TO THE ENGINEER.
7. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS.
8. DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESSOTHERWISE NOTED.
9. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTIONSAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
10. CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDEDFOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING,ANCHOR BOLTS, ETC.
11. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDSDRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK.
12. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING ORNONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILEREP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALLREQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING.
13. EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HISWORK WITH THE WORK OF OTHERS.
14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THISPROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTIONOF THE T-MOBILE CONSTRUCTION MANAGER.
15. ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURINGINSTALLATION USING A SILICONE SEALANT.
16. WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET,CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORDIMMEDIATELY.
17. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETEAND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT.
18. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OFEACH DAY.
19. CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWERCORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OFOTHER OCCUPANTS OF THE FACILITY.
20. CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC)WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK.
21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDEDSHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALLALL ITEMS PROVIDED.
22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIREDPERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THECONTRACTOR.
23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILESPECIFICATIONS AND REQUIREMENTS.
24. CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW ANDAPPROVAL PRIOR TO FABRICATION.
25. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'SSPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND ASSHOWN IN THESE PLANS.
26. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTIONMEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FORCOORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.
27. CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OFPOURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS ORSEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW ANDAPPROVAL.
28. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITHALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALLNECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICESSUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING,TRENCH BOXES/SLOPING, BARRIERS, ETC.
29. THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES ANDSUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANYDAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HISREPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THISCONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HISWORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HISEXPENSE TO THE OWNER'S SATISFACTION.
30. ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNERBY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIPSHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BYTHE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BEREPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL ISOBTAINED.
31. IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OFMATERIALS LISTED HEREINAFTER BY MANUFACTURER’S NAMES AND/ORMANUFACTURER’S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERSAS SPECIFIED.
32. T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE WAREHOUSE,NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTEDAND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACETHE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BERESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP.
33. T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANYEQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITHTHE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THEEQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THEREQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TOT-MOBILE OR THEIR ARCHITECT/ENGINEER.
SPECIAL CONSTRUCTIONANTENNA INSTALLATION NOTES:
1. WORK INCLUDED:
A. ANTENNA AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER ASEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNAINSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS.ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OFPERSONNEL.
B. INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILESPECIFICATIONS.
C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS.
D. INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE.
E. CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USINGANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCYDOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER.SWEEP TESTS SHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTINGRECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICEAND BE BOUND AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION.
F. INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS ANDEQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALLCONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'SREQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OFENTRY PORT LOCATION UNLESS OTHERWISE STATED.
G. ANTENNA AND COAXIAL CABLE GROUNDING:
2. ALL EXTERIOR #6 GREEN GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BEWEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OREQUAL.
3. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF
COAXIAL CABLE (NOT WITHIN BENDS)
ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESECONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATCENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN.
FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING ORANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR
APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLERESPONSIBILITY OF THE GENERAL CONTRACTOR.
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S 0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S 0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S 0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S
X X
X X X X X X
XX
XX
XX
XX
XX
XX
XX
XX
X
XXXXXXXXXXXXXXXXX
XX
XX
XX
XX
XX
XX
XX
XX
X
X X X X X X X X X
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
C-101
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
DETAILED SITE PLAN
0 FOR CONSTRUCTION ADE 06/02/22
0
1 DETAILED SITE PLAN
GRAPHIC SCALE
( IN FEET )1 UNIT = 10 FEET
105010
SITE PLAN NOTES:
1. THIS SITE PLAN REPRESENTS THE BESTPRESENT KNOWLEDGE AVAILABLE TO THEENGINEER AT THE TIME OF THIS DESIGN. THECONTRACTOR SHALL VISIT THE SITE PRIOR TOCONSTRUCTION AND VERIFY ALL EXISTINGCONDITIONS RELATED TO THE SCOPE OF WORKFOR THIS PROJECT.
2. ICE BRIDGE, CABLE LADDER, COAX PORT, ANDCOAX CABLE ARE SHOWN FOR REFERENCEONLY. CONTRACTOR SHALL CONFIRM THEEXACT LOCATION OF ALL PROPOSED ANDEXISTING EQUIPMENT AND STRUCTURESDEPICTED ON THIS PLAN. BEFORE UTILIZINGEXISTING CABLE SUPPORTS, COAX PORTS,INSTALLING NEW PORTS OR ANY OTHEREQUIPMENT, CONTRACTOR SHALL VERIFY ALLASPECTS OF THE COMPONENTS MEET THE ATCSPECIFICATIONS.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTORTO COORDINATE WITH THE T-MOBILEREPRESENTATIVE AND LOCAL UTILITY COMPANYFOR THE INSTALLATION OF CONDUITS,CONDUCTORS, BREAKERS, DISCONNECTS, ORANY OTHER EQUIPMENT REQUIRED FORELECTRICAL SERVICE. ALL ELECTRICAL WORKSHALL BE PERFORMED IN ACCORDANCE WITHLATEST EDITION OF THE STATE AND NATIONALCODES, ORDINANCES AND REGULATIONSAPPLICABLE TO THIS PROJECT.
LEGEND
AUTOMATIC TRANSFER SWITCHATS
DISCONNECTDELECTRICALEFIBERF
BOLLARDB
GENERATOR RECEPTACALGHAND HOLE, VAULTHH, VICE BRIDGEIBKENTROX BOXK
GENERATORGEN
METERMLIGHTING CONTROLLC
PULL BOXPBPOWER POLEPPTELCOTTRANSFORMERTRN
X CHAINLINK FENCE
GROUNDING TEST WELL
CELL SITE CABINETCSC
PROPOSED CABLE LENGTH:
1. ESTIMATED LENGTH OF PROPOSED CABLE IS 172'.ESTIMATED LENGTH OF CABLE WAS PROVIDED BYCUSTOMER OR CALCULATED BY ADDING THE RADCENTER AND THE DISTANCE FROM THE SHELTERENTRY PLATE TO THE TOWER (ALONG THE ICEBRIDGE) AND A SAFETY FACTOR MEASUREMENT OF15% (OF THE TWO PREVIOUS VALUES), CDS DEFERTO GREATEST CABLE LENGTH.
2. ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. IF ADEQUATE SPACEEXISTS, ROUTE CABLES THROUGH ENTRY PORTHOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXITPORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE,ATTACH CABLES USING STAND-OFF ADAPTERSMOUNTED TO TOWER USING STAINLESS STEELBANDING. ADEQUATELY SECURE CABLES USINGEITHER APPROPRIATELY SIZED STAINLESS STEELSNAP-INS OR MOUNTING HARDWARE AND BRACKETSAS SPECIFIED BY CABLE MANUFACTURER.
(12) 1 5/8" COAX CABLES(TO BE REMOVED)
(MODIFIED AS REQUIRED FOR UPGRADEFROM 67D94E TO 67D5D998E ODE+6160CONFIGURATION)
PROPOSED (2) 6X24 4AWG (1.99") HYBRID CABLES(ROUTED PER PROPOSED CABLE LENGTH NOTE 2)
(REFER TO PROPOSED CABLE LENGTH NOTE ON THIS PAGE)
1R-601
2C-102
4E-501
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
C-102
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
DETAILED GROUNDPLAN
SITE PLAN NOTES:
1. CONTRACTOR TO VERIFY THERE IS NO LIVE AAV FIBER RUNNING THROUGH EXISTING DEADEQUIPMENT. IF SO, THIS WILL NEED TO BE RERUN THROUGH CONDUIT PRIOR TO REMOVINGDEAD 2G (6201 CABS) EQUIPMENT.
2. ALL OPEN PORTS NEED TO BE SEALED / WEATHERPROOFED PROPERLY
3. ALL UNNEEDED / EXCESS EQUIPMENT AND GARBAGE TO BE REMOVED FROM EQUIPMENT AREA.DISPOSE OF MATERIALS PROPERLY OFF SITE.
T-MOBILE CM APPROVAL REQUIRED BEFORE INSTALLING CABINETS.ALL ABOVE GROUND CONDUIT LESS THAN 6" CAN BE LFMC.ALL ABOVE GROUND CONDUIT OVER 6" MUST BE RGS.ALL PVC CONDUIT MUST BE BURIED.
1 EXISTING GROUND EQUIPMENT LAYOUT 2 PROPOSED GROUND EQUIPMENT LAYOUT
GRAPHIC SCALE55
( IN FEET )1 UNIT = 5 FEET
0 2.5GRAPHIC SCALE
55
( IN FEET )1 UNIT = 5 FEET
0 2.5
(12) 1 5/8" COAX CABLES(TO BE REMOVED)
PROPOSED(2) 6X24 4AWG (1.99")HYBRID CABLES
(TO BE REMOVED)
(3) EXISTING DIPLEXERS(TO BE REMOVED)
PROPOSED ENCLOSURE6160 CABINET
1R-604
PROPOSED B160BATTERY CABINET
1R-606PROPOSED (2) RP 6651, (1) PSU
4813 vR4A VOLTAGE BOOSTER,AND (1) CSR IXRE V2 ROUTER
1R-603
1R-605
1'-0"8"
PROPOSED POWER CONDUITFROM EXISTING PPC TO
PROPOSED 6160 CABINET
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
C-201
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
TOWER ELEVATION
0 FOR CONSTRUCTION ADE 06/02/22
01 TOWER ELEVATIONSCALE: N.T.S.
TOWER NOTE:1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
CONFIRM WITH THE PROJECT MANAGER THATTHEY HAVE THE MOST RECENT VERSION OF THESTRUCTURAL ANALYSIS BEFORE COMMENCINGWORK. EXISTING AND PROPOSED TOWERAPPURTENANCES, MOUNTS, AND ANTENNAS ARESHOWN BASED ON THE STRUCTURAL ANALYSIS.
2. WHERE APPLICABLE, ALL NEW ANTENNAS,EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BEPAINTED/SOCKED TO MATCH EXISTING EQUIPMENTIN ACCORDANCE WITH FAA, JURISDICTION, AND/OROTHER LOCAL REQUIREMENTS.
3. ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. IF ADEQUATE SPACEEXISTS, ROUTE CABLES THROUGH ENTRY PORTHOLE, UP INSIDE OF MONOPOLE, AND THROUGHEXIT PORT HOLE. IF ROUTING OUTSIDE THEMONOPOLE, ATTACH CABLES USING STAND-OFFADAPTERS MOUNTED TO TOWER USING STAINLESSSTEEL BANDING. ADEQUATELY SECURE CABLESUSING EITHER APPROPRIATELY SIZED STAINLESSSTEEL SNAP-INS OR MOUNTING HARDWARE ANDBRACKETS AS SPECIFIED BY CABLEMANUFACTURER.
4. TOWER ELEVATIONS ARE MEASURED FROM TOPOF BASE PLATE TO MATCH STRUCTURALANALYSIS. ELEVATIONS DO NOT REFLECT TRUEABOVE GROUND LEVEL (A.G.L.)
5. TOWER ELEVATION DEPICTION MAY NOT REFLECTALL EQUIPMENT INCLUDED IN STRUCTURALANALYSIS. REFER TO STRUCTURAL ANALYSIS FORFULL TOWER LOADING.
PER MOUNT ANALYSIS COMPLETED BYAMERICAN TOWER CORP., DATED APRIL 27, 2022,THE EXISTING MOUNT MUST BE MODIFIED TOADEQUATELY SUPPORT THE PROPOSEDLOADING. THE MOUNT MODIFICATION DETAILEDAT THE END OF THIS PLAN SET, MUST BEINSTALLED PRIOR TO THE INSTALLATION OF THEPROPOSED ANTENNAS AND OTHER EQUIPMENT.
2C-401
PROPOSED T-MOBILEEQUIPMENT & MOUNT
MODIFICATIONS
1C-401
PROPOSED T-MOBILERAD CENTER @ 117'
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
C-401
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
ANTENNA INFORMATION& SCHEDULE
0 FOR CONSTRUCTION ADE 06/02/22
0
1 EXISTING ANTENNA PLANSCALE: N.T.S. 2 FINAL ANTENNA PLAN
SCALE: N.T.S.
3 EQUIPMENT SCHEDULES
FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY
MODEL NUMBER STATUS COAX HYBRID STATUS
(2) 6X24 (1.99") ADD
EXISTING FIBER DISTRIBUTION/OVP BOX EXISTING CABLING SUMMARY
MODEL NUMBER STATUS COAX HYBRID STATUS
(12) 1-5/8" RMV
CABLE LENGTHS FOR JUMPERS
JUNCTION BOX TO RRU: 15'RRU TO ANTENNA: 10'
1. CONFIRM WITH T-MOBILE REPFOR APPLICABLEUPDATES/REVISIONS ANDMOST RECENT RFDS FOR NSNCONFIGURATION (CONFIG). GCTO CAP ALL UNUSED PORTS.
2. CONFIRM SPACING OFPROPOSED EQUIP DOES NOTCAUSE TOWER CONFLICTSNOR IMPEDE TOWER CLIMBINGPEGS.
NOTES
STATUS ABBREVIATIONS
RMV: TO BE REMOVED: TO REMAIN
REL: TO BE RELOCATEDADD: TO BE ADDED
FINAL ANTENNA SCHEDULELOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY
SECTOR RAD AZ POS ANTENNA BAND MECH/ELECD-TILT STATUS ADDITIONAL TOWER
MOUNTED EQUIPMENT STATUS
ALPHA 117' 60°
A1 AIR 6419 B41 L2500/N2500 0°/2°,2° ADDA2 VV-65A-R1 L2100/L1900/G1900 0°/2°,2° ADD 4460 B25+B66 ADDA3
A4
BETA 117' 180°
B1 AIR 6419 B41 L2500/N2500 0°/2°,2° ADDB2 VV-65A-R1 L2100/L1900/G1900 0°/2°,2° ADD 4460 B25+B66 ADDB3
B4
GAMMA 117' 300°
C1 AIR 6419 B41 L2500/N2500 0°/2°,2° ADDC2 VV-65A-R1 L2100/L1900/G1900 0°/2°,2° ADD 4460 B25+B66 ADDC3
C4
EXISTING ANTENNA SCHEDULELOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY
SECTOR RAD AZ POS ANTENNA BAND MECH/ELECD-TILT STATUS ADDITIONAL TOWER
MOUNTED EQUIPMENT STATUS
APXV18-206517S-C-A20 L1900/G1900 0°/2° RMV KRY 112 489/2 RMV
4415 B66KRY 112 144/2
RMVRMV
APXV18-206517S-C-A20 L1900/G1900 0°/2° RMV KRY 112 489/2 RMV
4415 B66KRY 112 144
2
RMVRMV
APXV18-206517S-C-A20 L1900/G1900 0°/2° RMV KRY 112 489/2 RMV
4415 B66KRY 112 144
2
RMVRMV
PER MOUNT ANALYSIS COMPLETED BYAMERICAN TOWER CORP., DATED APRIL 27, 2022,THE EXISTING MOUNT MUST BE MODIFIED TOADEQUATELY SUPPORT THE PROPOSEDLOADING. THE MOUNT MODIFICATION DETAILEDAT THE END OF THIS PLAN SET, MUST BEINSTALLED PRIOR TO THE INSTALLATION OF THEPROPOSED ANTENNAS AND OTHER EQUIPMENT.
(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)
(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)
(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)
(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)
PROPOSED AIR 6419 B41 ANTENNA(1 PER SECTOR) (TYP. 3)
PROPOSED 4460 B25+B66 RRU(1 PER SECTOR) (TYP. 3)
PROPOSED VV-65A-R1 ANTENNA(1 PER SECTOR) (TYP. 3)
A1
A2
A4
B1B2B4
C1
C2
C4
AZ.=
ALPHA60°
AZ.= BE
TA180°
AZ.=GAMMA
300°
PROPOSED MOUNT MODIFICATIONS(REFER TO SHEETS AT THE END OFTHIS PLAN SET)
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
C-501
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
CONSTRUCTIONDETAILS
0 FOR CONSTRUCTION ADE 06/02/22
0
3 PROPOSED RRU MOUNTING DETAIL - TYPICALSCALE: N.T.S.
TO BE REPLACED WITH PROPOSED 2-3/8" O.D. X 96" LONGIF REQUIRED TO ACCOMMODATE PROPOSED MOUNTING BRACKET
1 PROPOSED ANTENNA MOUNTING DETAIL - TYPICALSCALE: N.T.S.
PROPOSED 2-3/8" O.D. X 96" LONG
PROPOSED ANTENNA
2 PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICALSCALE: N.T.S.
PROPOSED RRU MOUNT LOCATION (OPTION 2)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)
PROPOSED RRU MOUNT LOCATION (OPTION 1)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)
PROPOSED RRU MOUNT LOCATION (OPTION 3)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
E-501
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
GROUNDING DETAILS
0 FOR CONSTRUCTION ADE 06/02/22
0
NOTES:
1. THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHTADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THECONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THECONSTRUCTION MANAGER OF ANY CONFLICTS.
2. SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATESTEDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHENNATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN.
PROPOSED CONNECTOR ANDWEATHERPROOFING KIT
1 TYPICAL ANTENNA GROUNDING DIAGRAMSCALE: N.T.S.
PROPOSED ANTENNA
PROPOSED JUMPER
PROPOSED WEATHERPROOFING KIT
2E-501
3E-501
GROUND BAR MOUNTEDNEAR/BELOW ANTENNA(TO BE INSTALLED IFREQUIRED)
#6 AWG STRANDED CUWIRE WITH GREEN, 600V,THWN INSULATION
ANTENNA CABLE TOCABINET (TYP.)
PROPOSED CABLEGROUND KIT
PROPOSED #6 AWGSTRANDED CU
WIRE WITH GREEN, 600V,THWN INSULATION
TO PROPOSED RRUGROUND LUG (TYP.)
DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECTGROUND WIRE DOWN TO GROUND BAR.CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PARTNUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS.
2 CABLE GROUND KIT CONNECTION DETAILSCALE: N.T.S.
TO ANTENNA
TO EQUIPMENT
TO GROUND BAR
ANTENNA CABLE 2 1/2"Ø MAX
GROUNDING KIT PER CABLEMANUFACTURER'S RECOMMENDATIONS(ANDREW OR APPROVED EQUAL)
#6 AWG STRANDED COPPER GROUNDWIRE (GROUNDED TO GROUND BAR)
GROUND KIT NOTES:1.
2.
1/4" X 4" X 6" GROUND BAR(ERICO P/N: EGBA14406CC OR EQUAL)
3 TOWER GROUND BAR DETAILSCALE: N.T.S.
GROUND BAR NOTES:
1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS,WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S).
2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER.
3/8" SS LOCK WASHER(EACH SIDE)
TWO-HOLE LUG, TO BE USEDWITH #2 AWG BCW(LOWER TOWER GROUNDBAR ONLY)
3/8" X 1-1/2" SS BOLT(EACH SIDE)
OCPD SIZE WIRE SIZE GROUND SIZE CONDUIT SIZE
80A/2P 2#3 AWG #8 AWG 1-1/4"
100/2P 2#2 AWG #8 AWG 1-1/4"
125A/2P 2#1 AWG #8 AWG 1-1/2"
150A/2P 2#1/0 AWG #8 AWG 1-1/2"
ELECTRICAL NOTES:
1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATEWITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITYCOMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS,BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENTREQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORKSHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OFTHE STATE AND NATIONAL CODES, ORDINANCES ANDREGULATIONS APPLICABLE TO THIS PROJECT.
2. ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUNDEQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASEDON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE.CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HASSUFFICIENT SPACE FOR PROPOSED BREAKER. PROPOSED CABLEAND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART.
3. FOR SPECIFIC CABINET / ANCILLARY EQUIPMENT WIRINGREQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULDREFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FORTHIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITHLOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS &PRACTICES.
4 CABINET GROUNDING DETAILSCALE: N.T.S.
PROPOSED CABINET
#2 AWG STRANDED GREENINSULATED COPPER CONDUCTOR
06/03/2022
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
R-601
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
SUPPLEMENTAL2 ANTENNA CONFIGURATION
SCALE: NOT TO SCALE
NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDEDBY REQUEST OF CUSTOMER WITHOUT EDIT.
1 CABINET CONFIGURATIONSCALE: NOT TO SCALE
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
R-602
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
SUPPLEMENTAL
1 EQUIPMENT DETAILSSCALE: NOT TO SCALE
A
B
C
FRONT VIEW
TOP VIEW
SIDE VIEW
C
ERICSSON
FRONT VIEWSIDW VIEW
A
C B
TOP VIEW
RRU SPECIFICATIONS
RRU MODEL A B CWEIGHT
(LBS)
RADIO 4460 B25+B66 19.6" 15.7" 12.1" 109.0
ANTENNA SPECIFICATIONS
ANTENNA MODEL A B CWEIGHT
(LBS)
AIR6449 B41 33.1" 20.6" 8.6" 104.0
VV-65A-R1 54.7" 12.1" 4.6" 23.8
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
R-603
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
SUPPLEMENTAL
NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.
·
·
2.5" KNOCKOUTS w/ RIGID CONDUIT, LB CONDUIT BODYFOR ALARM CABLE & TEMP SENSOR ROUTING. CONDUITMUST BE PROPERLY SECURED TO PREVENT DAMAGE
2.5" KNOCKOUTS w/ RIGID CONDUIT, LB CONDUITBODY FOR BATTERY CABLE CONDUIT MUST BEPROPERLY SECURED TO PREVENT DAMAGE
2.5" KNOCKOUTS w/ RIGID CONDUIT, LB CONDUIT BODYFOR AAV FIBER OPTIC CABLE w/NID POWER. CONDUITMUST BE PROPERLY SECURED TO PREVENT DAMAGE
2.5" KNOCKOUTS w/ RIGID CONDUIT, LBCONDUIT BODY FOR MICROWAVE. CONDUITMUST BE PROPERLY SECURED TO PREVENTDAMAGE
2.5" KNOCKOUTS LOWER REARINTENDED FOR HYBRID/MLE CABLES
CABINET GROUND POINTS
2.5" KNOCKOUT w/ RIGID CONDUIT, LBCONDUIT BODY FOR AC POWER. CONDUITMUST BE PROPERLY SECURED TO PREVENTDAMAGE
2.5" KNOCKOUT UNUSED FORDEDICATED CIRCUIT TO SERVICEOUTLET
2.5" KNOCKOUTS w/ RIGID CONDUIT, LRCONDUIT BODY WILL BE USED FORINTER-BASEBAND CONNECTION RUNNINGCONDUIT TO LEGACY 6131,6201, ODE ORMUAC CABINETS FOR I. CONDUIT MUST BEPROPERLY SECURED TO PREVENT DAMAGE
CABINET LOWER 4" PLINTH CAN BEREMOVED FOR ADDITIONAL 12" PLINTH
CABINET GROUND POINT
63"
4"
33.6"
8" 25.6"
CABINET GROUND POINT5/8" PLUG TO BE PUNCHED TO 1.5" FORGPS/GNSS w/ 1" RIGID CONDUIT & LLCONDUIT BODY
4" R
EAR
CLE
ARAN
CE
25.6"
25.6
"
DOORCLOSED
25" D
OO
R O
PEN
25.6"
25.6
"
2.5"
17"
5"
22.5"
27"
(OPTIONAL) 2.5" DC POWERKNOCKOUT TO B160
(OPTIONAL) 2.5" KNOCKOUT w/ LB CONDUITBODY FOR ALARM & TEMP SENSOR ROUTINGTO B160
“”
”
(ALTERNATE) 1" CONDUIT w/ PULLING ELBOW TO PPC.(GENERATOR, PPC, ATS & TOWER ALARMS)
1" LB CONDUIT BODY TO 1" CONDUIT TO PPC.(GENERATOR, PPC, ATS & TOWER ALARMS)
2.5" KNOCKOUT UNUSED FORDEDICATED CIRCUIT TO SERVICEOUTLET
1 ERICSSON 6160 SITE SUPPORT CABINET SPECIFICATIONSSCALE: N.T.S.
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
R-604
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
SUPPLEMENTAL
DC POWER CABLES(SHOWN IN RED)
GROUND CABLES(SHOWN IN GREEN)
INTERNAL GROUND BAR
FIBER CABLES (SHOWN INYELLOW)
ETHERNET CABLES(SHOWN IN BLUE)
RECTIFIERS
CABLE CHASE
1U DCDU
BACKHAUL ROUTER
BASEBAND
EXPANSION SPACE (BB,MW, & VB)
VOLTAGE BOOSTER
SPACE INTENTIONALLY LEFTBLANK TO BE ABLE TO WORK ONINTERNAL CABLING & FOR SPD'SON THE BOTTOM
ACCESS SLOTS
DC DISTRIBUTION
20-60VDC15A
DCINPUT +12V
DCPSU250W
20-60VDC15A
DCINPUT +12V
DCPSU250W
PS1 PS2 NOKIA7250 IXR-E
24SFP +8SFP28
2QSFP28
ResetSD
Card PS2PS1 Stat Fan LOC USB MgmtConsole
1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18 19 2120 2322 24 25 26 27 28 3029 31 32 33 34
1PPS
20-60VDC15A
DCINPUT +12V
DCPSU250W
20-60VDC15A
DCINPUT +12V
DCPSU250W
PS1 PS2 NOKIA7250 IXR-E
24SFP +8SFP28
2QSFP28
ResetSD
Card PS2PS1 Stat Fan LOC USB MgmtConsole
1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18 19 2120 2322 24 25 26 27 28 3029 31 32 33 34
1PPS
NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.
1 ERICSSON 6160 CABINET DETAILSSCALE: N.T.S.
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
R-605
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
SUPPLEMENTAL
RETURN BUS BAR
-48V BUS
DC DISTRIBUTIONBREAKERS (21)
ALRM BOARD IB2
ALRM BOARD EIBRECTIFIERS (1-9)
POWER CONTROLLER
DC DISTRIBUTION UNIT
MAIN LOAD CONNECTORSMAIN LOAD CONNECTORS
PRIORITY LOAD CONNECTORS
LLVD2 #1-6CB SLOT #7-12LLVD1 #1-6CB SLOT #1-6
BLVD #1-6CB SLOT #13-21
NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.
1 ERICSSON 6160 ELECTRICAL DETAILSSCALE: N.T.S.
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
R-606
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
SUPPLEMENTAL
NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.
1 ERICSSON B160 BATTERY CABINET SPECIFICATIONSSCALE: N.T.S.
2.5" KNOCKOUTS w/ RIGID CONDUIT, LBCONDUIT BODY FOR ALARM CABLE & TEMPSENSOR ROUTING. CONDUIT MUST BEPROPERLY SECURED TO PREVENT DAMAGE
2.5" KNOCKOUTS w/ RIGID CONDUIT, LBCONDUIT BODY FOR BATTERY CABLE CONDUITMUST BE PROPERLY SECURED TO PREVENTDAMAGE
CABINET GROUND POINTS
(OPTIONAL) 2.5" DC POWERKNOCKOUTS TO 6160
(OPTIONAL) 2.5" KNOCKOUTS FOR ALARM &TEMP SENSOR ROUTING TO 6160
CABINET GROUND POINT
63"
29.5"
27.5"2"
CABINET GROUND POINT
4" R
EAR
CLE
ARAN
CE
2'-1 5/8"
27.5
"26
.5"
25A AUX BREAKERS, FANS,LIGHTS, ETC.
ALARM BOX, PRELABLED
3X BATTERY SHELVES, UP TO200A HR, w/ PREINSTALLEDHEATERS
BATTERY RACK
BATTERY RACK
BATTERY RACK
BATTERY VIBRATIONMOUNTS
·
·
“”
”
3 x 300A BREAKERS
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
SHEET NUMBER: REVISION:
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
R-607
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: 7442
THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR
WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES
TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT
NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.
CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED
CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY
THE LATEST VERSION.
DATE DRAWN: 06/02/22
ATC JOB NO:
CT508//VERIZON CHAPLINCUSTOMER ID:
14071468
CT11508FCUSTOMER #:
T Mobile ©
411216
ATC SITE NAME:CT CHAPLIN SOUTH CT
CT508//VERIZON CHAPLIN
123 PALMER ROADCHAPLIN, CT 06235-2416
ATC SITE NUMBER:
SITE ADDRESS:
T-MOBILE SITE NAME:
11490 BLUEGRASS PKWYLOUISVILLE, KY 40299
502-437-5252
DOPPOWEROF DESIGN
SRETTAP.E
KM
CITCENOCFOE
TS
L I C E N S E D
PROFES I NA ENGINR
ATN
UT
AR ON
S O L
EE
No. 31284
0 FOR CONSTRUCTION ADE 06/02/22
0
SUPPLEMENTAL
1 MOUNT ANALYSIS
NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMERWITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNTANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THECONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TOVERIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONSTRUCTION.
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
<<w=175; h=175; n=BLANK - SIG; a=11>>
PROJECT LOCATIONGEOGRAPHIC COORDINATES
LATITUDE: 41.784528
LONGITUDE: -72.135694
PROJECT TEAM
TOWER OWNERAMERICAN TOWER
10 PRESIDENTAL WAY
WOBURN, MA 01801
ENGINEERED BYATC TOWER SERVICES
3500 REGENCY PARKWAY, SUITE 100
CARY, NC 27518
CARRIER INFORMATIONCARRIER: T-MOBILE
CARRIER SITE NAME: CT508//VERIZON CHAPLIN
CARRIER SITE NUMBER: CT11508F
SHEET SHEET TITLE REV.G-002 IBC GENERAL NOTES & MOUNT MODIFICATION INSPECTION 0S-101 MODIFICATION PROFILE 0R-901 SUPPLEMENTAL 0R-902 SUPPLEMENTAL 0R-903 SUPPLEMENTAL 0R-904 SUPPLEMENTAL 0
PROJECT DESCRIPTIONTHE PROJECT DEPICTED IN THESE PLANS ARE BASED ON THERECOMMENDATIONS OUTLINED IN THE STRUCTURAL ANALYSIS COMPLETEDUNDER ENGINEERING PROJECT NUMBER 14071468_C8_01 DATED 04/04/22.SATISFACTORY COMPLETION OF THE WORK INDICATED IN THESE PLANS WILLRESULT IN THE STRUCTURE MEETING THE REQUIREMENTS OF THESPECIFICATIONS UNDER WHICH THE STRUCTURAL WAS COMPLETED.
PROJECT NOTETHE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLEFACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C.§ 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THATINVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OFTRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDERCFR § 1.6100 (B)(7).
COMPLIANCE CODEALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED INACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES ASADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESEPLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESECODES.
1. ANSI/TIA/EIA: STRUCTURAL STANDARDS (222-H EDITION)
2. INTERNATIONAL BUILDING CODE (2018 IBC)
3. CONNECTICUT STATE BUILDING CODE (2018)
SITE NAME:SITE NUMBER:
ATC PROJECT NUMBER:SITE ADDRESS:
CT CHAPLIN SOUTH CT41121614071468_C9_04123 PALMER RDCHAPLIN, CT 06235
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.
DESCRIPTIONREV. DATEBY
ATC SITE NUMBER:
ATC SITE NAME:
SITE ADDRESS:
ATC JOB NO:
DRAWN BY:
APPROVED BY:
DATE DRAWN:
SHEET NUMBER: REVISION:
411216
CT CHAPLIN SOUTH CT
CONNECTICUT
123 PALMER RDCHAPLIN, CT 06235
KJ
MCC
04/29/2214071468_C9_04
G-001
A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: PEC.0001553
COVER
0 FIRST ISSUE KJ 04/29/22
0
VICINITY MAP LOCATION MAP
PALMER RD
SITE LOCATION
PLEASE CONTACT [email protected] ORAMERICAN TOWER NOC AT 877-518-6937 FOR ASSISTANCE
BIRD WATCH SITE:MOUNT REINFORCEMENT DRAWINGS
PREPARED FOR T-MOBILE
RIDGE RD
PHO
ENIX
VILL
E RD
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
<<w=175; h=175; n=BLANK - SIG; a=11>>
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.
DESCRIPTIONREV. DATEBY
ATC SITE NUMBER:
ATC SITE NAME:
SITE ADDRESS:
ATC JOB NO:
DRAWN BY:
APPROVED BY:
DATE DRAWN:
SHEET NUMBER: REVISION:
411216
CT CHAPLIN SOUTH CT
CONNECTICUT
123 PALMER RDCHAPLIN, CT 06235
KJ
MCC
04/29/2214071468_C9_04
G-002
A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: PEC.0001553
IBC GENERAL NOTES &MOUNT MODIFICATION
INSPECTION
0 FIRST ISSUE KJ 04/29/22
0
MAXIMUM ALLOWABLE ANGLE CLIP
1.5 X LMAX.
L
AREA OF ANGLETO BE CLIPPED
GENERAL1. ALL WORK TO BE COMPLETED PER APPLICABLE LOCAL, STATE, FEDERAL CODES AND
ORDINANCES AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS FOR WIRELESSTOWER SITES. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND ABIDING BYALL REQUIRED PERMITS.
2. ALL WORK INDICATED ON THESE DRAWINGS SHALL BE PERFORMED BY QUALIFIEDCONTRACTORS EXPERIENCED IN TOWER AND FOUNDATION CONSTRUCTION.
3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY OF ANYINSTALLATION INTERFERENCES. ALL NEW WORK SHALL ACCOMMODATE EXISTINGCONDITIONS. DETAILS NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL FOLLOWSIMILAR DETAILS FOR THIS JOB.
4. ANY SUBSTITUTIONS SHALL CONFORM TO THE REQUIREMENTS OF THESE NOTES ANDSPECIFICATIONS, AND SHOULD BE SIMILAR TO THOSE SHOWN. ALL SUBSTITUTIONSSHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVALPRIOR TO FABRICATION.
5. ANY MANUFACTURED DESIGN ELEMENTS SHALL CONFORM TO THE REQUIREMENTS OFTHESE NOTES AND SPECIFICATIONS AND SHOULD BE SIMILAR TO THOSE SHOWN.THESE DESIGN ELEMENTS MUST BE STAMPED BY AN ENGINEER PROFESSIONALLYREGISTERED IN THE STATE OF THE PROJECT, AND SUBMITTED TO THE ENGINEER OFRECORD FOR APPROVAL PRIOR TO FABRICATION.
6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL CODES AND OSHA SAFETYREGULATIONS.
7. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALLMISCELLANEOUS SHORING, BRACING, TEMPORARY SUPPORTS, ETC. NECESSARY, PERANSI/TIA-322 AND ANSI/ASSE A10.48, TO PROVIDE A COMPLETE AND STABLESTRUCTURE AS SHOWN ON THESE DRAWINGS.
8. CONTRACTOR'S PROPOSED INSTALLATION SHALL NOT INTERFERE, NOR DENY ACCESSTO, ANY EXISTING OPERATIONAL AND SAFETY EQUIPMENT.
STRUCTURAL STEEL1. ALL DETAILING, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM
TO THE AISC SPECIFICATIONS, LATEST EDITION.
2. ALL EXPOSED STRUCTURAL STEEL MEMBERS SHALL BE HOT-DIPPED GALVANIZEDAFTER FABRICATION PER ASTM A123. EXPOSED STEEL HARDWARE AND ANCHORBOLTS SHALL BE GALVANIZED PER ASTM A153 OR B695.
3. ALL U-BOLTS SHALL BE ASTM A36 OR EQUIVALENT, WITH LOCKING DEVICE, UNLESSNOTED OTHERWISE.
4. FIELD CUT EDGES, EXCEPT DRILLED HOLES, SHALL BE GROUND SMOOTH.
5. ALL FIELD CUT SURFACES, FIELD DRILLED HOLES & GROUND SURFACES WHEREEXISTING PAINT OR GALVANIZATION REMOVAL WAS REQUIRED SHALL BE REPAIREDWITH (2) BRUSHED COATS OF ZRC GALVILITE COLD GALVANIZING COMPOUND PERASTM A780 AND MANUFACTURERS RECOMMENDATIONS.
6. ALL STRUCTURAL STEEL EMBEDDED IN THE CONCRETE SHALL BE APPLIED WITH (2)BRUSHED COATS OF POLYGUARD CA-14 MASTIC OR EQUIVALENT. REFER TO THEMANUFACTURER SPECIFICATIONS FOR SURFACE PREPARATION AND APPLICATION.APPLICATION OF POLYGUARD 400 WRAP IS NOT ESSENTIAL.
7. CONTRACTOR SHALL PERFORM WORK ON ONLY ONE (1) TOWER FACE ANDREPLACE/REINFORCE ONE (1) BOLT/MEMBER AT A TIME.
8. ALL FIELD DRILLED HOLES TO BE USED FOR FIELD BOLTING INSTALLATION SHALL BESTANDARD HOLES, AS DEFINED BY AISC, UNLESS NOTED OTHERWISE.
PAINT1. AS REQUIRED, CLEAN AND PAINT PROPOSED STEEL ACCORDING TO FAA ADVISORY
CIRCULAR AC 70/7460-1L.
WELDING1. ALL WELDING TO BE PERFORMED BY AWS CERTIFIED WELDERS AND CONDUCTED IN ACCORDANCE
WITH THE LATEST EDITION OF THE AWS WELDING CODE D1.1.
2. ALL WELDS SHALL BE INSPECTED VISUALLY. IF DIRECTED BY ENGINEER OF RECORD, 25% OF WELDSSHALL BE INSPECTED WITH DYE PENETRANT OR MAGNETIC PARTICLE (100% IF REJECTABLE DEFECTSARE FOUND) TO MEET THE ACCEPTANCE CRITERIA OF AWS D1.1. REPAIR ALL WELDS AS NECESSARY.
3. INSPECTION SHALL BE PERFORMED BY AN AWS CERTIFIED WELD INSPECTOR.
4. ALL ELECTRODES TO BE LOW HYDROGEN, MATCHING FILLER AND/OR BASE METAL, PER AWS D1.1,UNLESS NOTED OTHERWISE.
5. IN CASES WHERE BASE METAL GRADE IS UNKNOWN, ALL WELDING ON LATTICE TOWERS SHALL BEDONE WITH E70XX ELECTRODES; ALL WELDING ON POLE STRUCTURES SHALL BE DONE WITH E80XXELECTRODES, UNLESS NOTED OTHERWISE.
6. PRIOR TO FIELD WELDING GALVANIZED MATERIAL, CONTRACTOR SHALL GRIND OFF GALVANIZING 1/2"BEYOND ALL FIELD WELD SURFACES. AFTER WELD AND WELD INSPECTION IS COMPLETE, REPAIR ALLGROUND AND WELDED SURFACES WITH ZRC GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780AND MANUFACTURERS RECOMMENDATIONS.
BOLT TIGHTENING PROCEDURE1. STRUCTURAL CONNECTIONS TO BE ASSEMBLED AND INSPECTED IN ACCORDANCE WITH RCSC
SPECIFICATIONS.
2. FLANGE BOLTS SHALL BE INSTALLED AND TIGHTENED USING DIRECT TENSION INDICATING (DTI)SQUIRTER WASHERS. DTI SQUIRTER WASHERS ARE TO BE INSTALLED AND ORIENTED / TIGHTENED PERMANUFACTURER SPECIFICATIONS TO ACHIEVE DESIRED LEVEL OF BOLT PRE-TENSION.
3. IN LIEU OF USING DTI SQUIRTER WASHERS, FLANGE BOLTS MAY BE TIGHTENED USING AISC / RCSC"TURN-OF-THE-NUT" METHOD, PENDING APPROVAL BY THE ENGINEER OF RECORD (EOR). TIGHTENFLANGE BOLTS USING THE CHART BELOW:
BOLT LENGTHS UP TO AND INCLUDING FOUR DIAMETERS1/2" BOLTS UP TO AND INCLUDING 2.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT5/8" BOLTS UP TO AND INCLUDING 2.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT3/4" BOLTS UP TO AND INCLUDING 3.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT7/8" BOLTS UP TO AND INCLUDING 3.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1" BOLTS UP TO AND INCLUDING 4.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-1/8" BOLTS UP TO AND INCLUDING 4.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-1/4" BOLTS UP TO AND INCLUDING 5.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-3/8" BOLTS UP TO AND INCLUDING 5.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-1/2" BOLTS UP TO AND INCLUDING 6.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT
BOLT LENGTHS OVER FOUR DIAMETERS BUT NOT EXCEEDING EIGHT DIAMETERS1/2" BOLTS 2.25 TO 4.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT5/8" BOLTS 2.75 TO 5.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT3/4" BOLTS 3.25 TO 6.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT7/8" BOLTS 3.75 TO 7.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1" BOLTS 4.25 TO 8.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-1/8" BOLTS 4.75 TO 9.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-1/4" BOLTS 5.25 TO 10.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-3/8" BOLTS 5.75 TO 11.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-1/2" BOLTS 6.25 TO 12.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT
BOLT TIGHTENING PROCEDURE (CONTINUED)4. SPLICE BOLTS SUBJECT TO DIRECT TENSION SHALL BE INSTALLED AND TIGHTENED AS PER
SECTION 8.2.1 OF THE AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490BOLTS", LOCATED IN THE AISC MANUAL OF STEEL CONSTRUCTION. THE INSTALLATIONPROCEDURE IS PARAPHRASED AS FOLLOWS:
FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES AND TIGHTENED BY ONEOF THE METHODS DESCRIBED IN SUBSECTION 8.2.1 THROUGH 8.2.4.
8.2.1 TURN-OF-NUT PRETENSIONINGBOLTS SHALL BE INSTALLED IN ALL HOLES OF THE CONNECTION AND BROUGHT TO ASNUG TIGHT CONDITION AS DEFINED IN SECTION 8.1, UNTIL ALL THE BOLTS ARESIMULTANEOUSLY SNUG TIGHT AND THE CONNECTION IS FULLY COMPACTED.FOLLOWING THIS INITIAL OPERATION ALL BOLTS IN THE CONNECTION SHALL BETIGHTENED FURTHER BY THE APPLICABLE AMOUNT OF ROTATION SPECIFIED ABOVE.DURING THE TIGHTENING OPERATION THERE SHALL BE NO ROTATION OF THE PART NOTTURNED BY THE WRENCH. TIGHTENING SHALL PROGRESS SYSTEMATICALLY.
5. ALL OTHER BOLTED CONNECTIONS SHALL BE BROUGHT TO A SNUG TIGHT CONDITION AS DEFINEDIN SECTION 8.1 OF THE SPECIFICATION.
ALL BOLT HOLES SHALL BE ALIGNED TO PERMIT INSERTION OF THE BOLTS WITHOUTUNDUE DAMAGE TO THE THREADS. BOLTS SHALL BE PLACED IN ALL HOLES WITHWASHERS POSITIONED AS REQUIRED AND NUTS THREADED TO COMPLETE THEASSEMBLY. COMPACTING THE JOINT TO THE SNUG-TIGHT CONDITION SHALL PROGRESSSYSTEMATICALLY FROM THE MOST RIGID PART OF THE JOINT. THE SNUG-TIGHTENEDCONDITION IS THE TIGHTNESS THAT IS ATTAINED WITH A FEW IMPACTS OF AN IMPACTWRENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCHTO BRING THE CONNECTED PLIES INTO FIRM CONTACT.
MODIFICATION INSPECTION NOTESTHE MOUNT MODIFICATION INSPECTION (MMI) PROCEDURE IS INTENDED TO CONFIRM THAT CONSTRUCTION ANDINSTALLATION MEETS ENGINEERING DESIGN, ATC PROCEDURES AND ATC STANDARD SPECIFICATIONS FORWIRELESS TOWER SITES.
TO ENSURE THAT THE REQUIREMENTS OF THE MMI ARE MET, IT IS VITAL THAT THE GENERAL CONTRACTOR SUBMITALL REQUIRED PHOTOGRAPHS AND DRAWINGS TO AMERICAN TOWER CORPORATION (ATC).
GENERAL CONTRACTORTHE GENERAL CONTRACTOR IS REQUIRED TO:
· REVIEW THE REQUIREMENTS OF THE MMI CHECKLIST.
· UNDERSTAND ALL INSPECTION REQUIREMENTS.
THE GENERAL CONTRACTOR SHALL PERFORM AND RECORD THE INSPECTION RESULTS INACCORDANCE WITH THE REQUIREMENTS OF THE MMI CHECKLIST.
MOUNT MODIFICATION INSPECTION CHECKLIST
INSPECTION DOCUMENT DESCRIPTION INSPECTION TESTINGREQUIRED RESPONSIBILITY
ON-SITE COLD GALVANIZING VERIFICATION PHOTOGRAPHIC EVIDENCE OF COLD GALVANIZATION TYPE AND APPLICATION IN ALL APPLICABLE LOCATIONS TO BE INCLUDED WITHIN THE MMIREPORT GC
GC AS-BUILT DRAWINGS WITHCONSTRUCTION RED-LINES
"AS-BUILT" DRAWINGS INDICATING ANY APPROVED CHANGES TO ENGINEERED PLANS TO MMI FOR APPROVAL/REVIEW ANDINCLUSION IN MMI REPORT GC
PHOTOGRAPHSPHOTOGRAPHIC EVIDENCE OF MOUNT MODIFICATION INSPECTION, ON SITE REMEDIATION, AND ITEMS FAILING INSPECTION &REQUIRING FOLLOW UP TO BE INCLUDED WITHIN THE MMI REPORT. COMPLETE PHOTO LOG IS TO BE SUBMITTED WITHIN MMIREPORT.
GC
TABLE KEY:MMI - MOUNT MODIFICATION INSPECTIONGC - GENERAL CONTRACTORATC - AMERICAN TOWER CORPORATION
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
<<w=175; h=175; n=BLANK - SIG; a=11>>
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.
DESCRIPTIONREV. DATEBY
ATC SITE NUMBER:
ATC SITE NAME:
SITE ADDRESS:
ATC JOB NO:
DRAWN BY:
APPROVED BY:
DATE DRAWN:
SHEET NUMBER: REVISION:
411216
CT CHAPLIN SOUTH CT
CONNECTICUT
123 PALMER RDCHAPLIN, CT 06235
KJ
MCC
04/29/2214071468_C9_04
S-101
A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: PEC.0001553
MODIFICATION PROFILE
0 FIRST ISSUE KJ 04/29/22
0
NOTES:1. CONTRACTOR TO INSTALL MOUNT MODIFICATIONS PER THE MANUFACTURERS SPECIFICATION.
MODIFICATIONS SHALL NOT OBSTRUCT, INTERFERE, OR BLOCK EXISTING SAFETY CLIMB SYSTEM.IF ANY OF THESE OCCURS DURING INSTALLATION CONTACT THE AMERICAN TOWER PMI [email protected]
2. IN THE EVENT A PROPOSED MODIFICATION PART LISTED IN THE DRAWINGS IS NOT AVAILABLE, ANAPPROVED EQUIVALENT CAN BE SUBSTITUTED. FOR APPROVAL OF EQUIVALENT PART ORQUESTIONS PLEASE CONTACT AMERICAN TOWER PMI INBOX AT [email protected].
SAFETY CLIMB LOCATION
MOUNT MODIFICATIONFRONT VIEW
MOUNT MODIFICATIONISOMETRIC VIEW
MOUNT MODIFICATIONTOP VIEW
PROPOSEDSITE PRO 1 HANDRAIL REINFORCEMENT KIT
[PRK-SFS]
7'-3"2'
-0"
PROPOSEDSITE PRO 1 HANDRAIL REINFORCEMENT KIT
[PRK-SFS]
PROPOSEDSITE PRO 1 HANDRAIL REINFORCEMENT KIT
[PRK-SFS]
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
<<w=175; h=175; n=BLANK - SIG; a=11>>
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.
DESCRIPTIONREV. DATEBY
ATC SITE NUMBER:
ATC SITE NAME:
SITE ADDRESS:
ATC JOB NO:
DRAWN BY:
APPROVED BY:
DATE DRAWN:
SHEET NUMBER: REVISION:
411216
CT CHAPLIN SOUTH CT
CONNECTICUT
123 PALMER RDCHAPLIN, CT 06235
KJ
MCC
04/29/2214071468_C9_04
R-901
A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: PEC.0001553
SUPPLEMENTAL
0 FIRST ISSUE KJ 04/29/22
0
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
<<w=175; h=175; n=BLANK - SIG; a=11>>
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.
DESCRIPTIONREV. DATEBY
ATC SITE NUMBER:
ATC SITE NAME:
SITE ADDRESS:
ATC JOB NO:
DRAWN BY:
APPROVED BY:
DATE DRAWN:
SHEET NUMBER: REVISION:
411216
CT CHAPLIN SOUTH CT
CONNECTICUT
123 PALMER RDCHAPLIN, CT 06235
KJ
MCC
04/29/2214071468_C9_04
R-902
A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: PEC.0001553
SUPPLEMENTAL
0 FIRST ISSUE KJ 04/29/22
0
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
<<w=175; h=175; n=BLANK - SIG; a=11>>
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.
DESCRIPTIONREV. DATEBY
ATC SITE NUMBER:
ATC SITE NAME:
SITE ADDRESS:
ATC JOB NO:
DRAWN BY:
APPROVED BY:
DATE DRAWN:
SHEET NUMBER: REVISION:
411216
CT CHAPLIN SOUTH CT
CONNECTICUT
123 PALMER RDCHAPLIN, CT 06235
KJ
MCC
04/29/2214071468_C9_04
R-903
A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: PEC.0001553
SUPPLEMENTAL
0 FIRST ISSUE KJ 04/29/22
0
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
<<w=175; h=175; n=BLANK - SIG; a=11>>
Cop
yrig
ht ©
20
22 A
TC IP
LLC
, All
Rig
hts
Res
erve
d.
THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.
DESCRIPTIONREV. DATEBY
ATC SITE NUMBER:
ATC SITE NAME:
SITE ADDRESS:
ATC JOB NO:
DRAWN BY:
APPROVED BY:
DATE DRAWN:
SHEET NUMBER: REVISION:
411216
CT CHAPLIN SOUTH CT
CONNECTICUT
123 PALMER RDCHAPLIN, CT 06235
KJ
MCC
04/29/2214071468_C9_04
R-904
A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY
SUITE 100CARY, NC 27518
PHONE: (919) 468-0112COA: PEC.0001553
SUPPLEMENTAL
0 FIRST ISSUE KJ 04/29/22
0
DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Post Modification Mount Analysis Report
ATC Site Name : CT Chaplin South CT, CT
ATC Site Number : 411216
Engineering Number : 14071468_C9_04
Mount Elevation : 116 ft
Carrier : T-Mobile
Carrier Site Name : CT508//Verizon Chaplin
Carrier Site Number : CT11508F
Site Location : 123 Palmer Road
Chaplin, CT 06235-2416
41.78454665 , -72.13571997
County : Windham
Date : April 27, 2022
Max Usage : 45%
Result : Contingent Pass
Prepared By:
Mitchell Chen
Structural Engineer II
Reviewed By:
COA: PEC.0001553
Eng. Number 14071468_C9_04 April 27, 2022
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Table of Contents Introduction ....................................................................................................................................................... 1 Supporting Documents ..................................................................................................................................... 1 Analysis ............................................................................................................................................................... 1 Conclusion .......................................................................................................................................................... 1 Application Loading ........................................................................................................................................... 2 Structure Usages................................................................................................................................................ 2 Mount Layout .................................................................................................................................................... 3 Equipment Layout ............................................................................................................................................. 4 Standard Conditions ........................................................................................................................................... 7 Calculations .......................................................................................................................................... Attached
Eng. Number 14071468_C9_04 April 27, 2022
Page 1
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Introduction
The purpose of this report is to summarize results of the mount analysis performed for T-Mobile at 116 ft. Supporting Documents
Specifications Sheet Site Pro 1 RMQP-496-HK, dated May 23, 2021
Radio Frequency Data Sheet RFDS ID #CT11508F, dated March 2, 2022
Reference Photos Site photos from 2020
Analysis
This mount was analyzed using American Tower Corporation’s Mount Analysis Program and RISA-3D
Basic Wind Speed: 120 mph (3-Second Gust)
Basic Wind Speed w/ Ice: 50 mph (3-Second Gust) w/ 1.00'' radial ice concurrent
Codes: ANSI/TIA-222-H
Exposure Category: B
Risk Category: II
Topographic Factor Procedure: Method 2
Feature: Flat
Crest Height (H): 0 ft
Crest Length (L): 0 ft
Spectral Response: Ss = 0.185, S1 = 0.055
Site Class: D - Stiff Soil
Live Loads: Lm = 500 lbs * Based on experience, it has been determined that the Lv load cases will not control over Lm load cases in platform mount analyses. Therefore, these load cases have been excluded from this analysis.
Conclusion
Based on the analysis results, the antenna mount meets the requirements per the applicable codes listed above provided the modifications listed below are completed:
• Install modification per ATC Drawing #14071468_C9_04
If you have any questions or require additional information, please contact American Tower via email at [email protected]. Please include the American Tower site name, site number, and engineering number in the subject line for any questions.
Eng. Number 14071468_C9_04 April 27, 2022
Page 2
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Application Loading
Mount Centerline
(ft)
Equipment Centerline
(ft) Qty Equipment Manufacturer & Model
116.0 117.0
3 Commscope VV-65A-R1
3 Ericsson AIR 6419 B41
3 RFS APXVAARR24_43-U-NA20
3 Ericsson Radio 4449 B71 B85A
3 Ericsson 4460 BAND 2/25
Structure Usages
Structural Component Controlling Usage Pass/Fail
Horizontals 28% Pass
Tie-Backs 10% Pass
Mount Pipes 45% Pass
Connection Check 15% Pass
Eng. Number 14071468_C9_04 April 27, 2022
Page 3
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Mount Layout
Eng. Number 14071468_C9_04 April 27, 2022
Page 4
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Equipment Layout
Mount Pipe A Mount Pipe B
Mount Pipe C Mount Pipe D
Eng. Number 14071468_C9_04 April 27, 2022
Page 5
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Equipment Layout Cont'd.
Mount Pipe E Mount Pipe F
Mount Pipe G Mount Pipe H
Eng. Number 14071468_C9_04 April 27, 2022
Page 6
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Equipment Layout Cont'd.
Mount Pipe I Mount Pipe J
Mount Pipe K Mount Pipe L
Eng. Number 14071468_C9_04 April 27, 2022
Page 7
A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com
Standard Conditions
All engineering services performed by A.T. Engineering Service, PLLC are prepared on the basis that the information used is current and correct. This information may consist of, but is not limited to the following:
• Information supplied by the client regarding equipment, mounts and feed line loading
• Information from drawings, design and analysis documents, and field notes in the possession of A.T. Engineering Service, PLLC
It is the responsibility of the client to ensure that the information provided to A.T. Engineering Service, PLLC and used in the performance of our engineering services is correct and complete. American Tower assumes that all structures were constructed in accordance with the drawings and specifications. All connections are to be verified for condition and tightness by the installation contractor preceding any changes to the appurtenance mounting system and/or equipment attached to it. Unless explicitly agreed by both the client and A.T. Engineering Service, PLLC, all services will be performed in accordance with the current revision of ANSI/TIA-222. Installation of all equipment and steel should be confirmed not to cause tower conflicts nor impede the tower climbing pegs. All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. A.T. Engineering Service, PLLC is not responsible for the conclusions, opinions and recommendations made by others based on the information supplied herein.
Site Number:
Project Number:
Carrier:
Mount Elevation:
Date:
Velocity Pressure Coefficient Kz 1.03 Short Period DSRAP SDS
Topographic Factor Kzt 1.00 1 Second DSRAP SD1
Rooftop Wind Speed-up Factor Ks 1.00 Importance Factor I
Shielding Factor Ka 0.90 Response Modification Coefficient R
Ground Elevation Factor Ke 0.98 Seismic Response Coefficient CS
Wind Direction Probability Factor Kd 0.95 Amplification Factor A
Basic Wind Speed V 120 mph Total Weight W lbs
Velocity Pressure qz 35.5 psf Total Shear Force VS lbs
Height Escalation Factor Kiz 1.13 Horizontal Seismic Load Eh lbs
Thickness of Radial Glaze Ice Tiz 1.13 in Vertical Seismic Load Ev lbs
Height Depth Weight EPAN EPAT
in in lbs sqft sqft
54.7 4.6 23.8 5.93 1.43
36.3 9.0 83.3 6.32 1.82
95.9 8.7 127.9 20.24 3.48
15.0 10.5 75.0 1.65 1.31
19.6 12.1 109.0 2.56 1.98
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A
Mount Analysis Force Calculations
411216
14071468_C9_04
T-Mobile
116 ft
4/27/2022
114.4
Wind & Ice Load Calculations
Commscope VV-65A-R1
Equipment
1.0
0.088
0.197
Seismic Load Calculations
286.1
286.1
2899.8
1.0
0.099
2.0
sqft
2.22
Model #
Antenna Calculations (Elevations per Application/RFDS)*
7.33
EPANi
7.45
22.68
2.23
2.42
4.49
1.84
Ericsson AIR 6419 B41
RFS APXVAARR24_43-U-NA20
Ericsson Radio 4449 B71 B85A
#N/A
2.62
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
Ericsson 4460 BAND 2/25 3.27
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
EPATiWidth
in
12.1
20.9
24.0
13.2
15.7
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
sqft
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
* Equipment with EPA values N/A were not considered in the mount analysis
Site Number:
Project Number:
Carrier:
Mount Elevation:
Date:
Controlling Load Combination 11
Node Label N002
Force in X Fx -974.4 lbs
Force in Y Fy -173.9 lbs
Force in Z Fz 1615.0 lbs
Moment about X Mx -212.6 lb-ft
Moment about Y My 1289.8 lb-ft
Moment about Z Mz -127.8 lb-ft
Bolt Quantity n 4
Bolt Diameter DB 5/8 in
Bolt Edge Distance e 1 in
Bolt Grade A325
Bolt Fy FyB 92 ksi
Bolt Fu FuB 120 ksi Standoff Type
Applied Shear Vu 0.22 k Standoff Member
Applied Tension Tu 1.91 k Member Edge Distance E 2 in
Tensile Strength φTn 20.3 k Member Width w 4 in
Interaction Capacity (Tu+Vu)/φTn 10% Pass Member Thickness t 0.250 in
Member Grade A53 Gr. B
Member Fy FyM 35 ksi
Plate Height H 8 in Member Fu FuM 60 ksi
Plate Width W 8 in Weld Size a 1/4 in
Plate Thickness T 1/2 in Weld Length l 16.0 in
Plate Grade A36 Applied Load Pu 3.8 k
Plate Fy FyP 36 ksi Weld Strength φRn 44.5 k
Plate Fu FuP 58 ksi Weld Capacity Pu/φRn 9% Pass
Shear Capacity φVn 26.9 k
Applied Moment Mu 3.8 k-in Minimum Base Metal Thickness 0.206 in
Flexural Strength φMn 26.1 k-in Controlling Base Metal Thickness 0.250 in
Flexural Capacity Mu/φMn 15% Pass Base Metal Result
Moment Arm b 1.00 in Minimum Thickness tmin 0.14 in
Effective Moment Arm b' 0.69 in No Prying Thickness tnp 0.19 in
Tributary Length p 2.75 in Min Bolt Strength Thickness tc 0.62 k-in
Effective Edge Distance a' 1.31 in Prying Action Bolt Tension Tup 0.00 k
Prying Action Considerations
Acceptable
A.T. Engineering Service, PLLC
411216
14071468_C9_04
T-Mobile
116 ft
4/27/2022
Plate Flexural Capacity
Mount-to-Tower Connection Analysis
Applied Loads from RISA 3D
Bolt Shear and Tensile Capacity
Weld and Base Metal Capacity
Tube
HSS4x4x4
v1.1
CompanyDesignerJob NumberModel Name
::::
American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT
Checked By : -
4/27/202210:16:31 AM
RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 1
CompanyDesignerJob NumberModel Name
::::
American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT
Checked By : -
4/27/202210:16:31 AM
RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 2
CompanyDesignerJob NumberModel Name
::::
American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT
Checked By : -
4/27/202210:16:31 AM
RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 3
CompanyDesignerJob NumberModel Name
::::
American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT
Checked By : -
4/27/202210:16:31 AM
RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 4
CompanyDesignerJob NumberModel Name
::::
American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT
Checked By : -
4/27/202210:16:31 AM
RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 5
CompanyDesignerJob NumberModel Name
::::
American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT
Checked By : -
4/27/202210:16:31 AM
RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 6
CompanyDesignerJob NumberModel Name
::::
American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT
Checked By : -
4/27/202210:16:31 AM
RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 7
Basic Load Cases
BLC Description Category Y Gravity Nodal Point Distributed Surface(Plate/Wall)1 D DL -1 242 Di IL 24 60 33 W 0 WL 24 964 W 30 WL 48 1925 W 60 WL 48 1926 W 90 WL 24 997 W 120 WL 48 1928 W 150 WL 48 1929 W 180 WL 24 96
10 W 210 WL 48 19211 W 240 WL 48 19212 W 270 WL 24 9913 W 300 WL 48 19214 W 330 WL 48 19215 Wi 0 WL 24 9616 Wi 30 WL 48 19217 Wi 60 WL 48 19218 Wi 90 WL 24 9919 Wi 120 WL 48 19220 Wi 150 WL 48 19221 Wi 180 WL 24 9622 Wi 210 WL 48 19223 Wi 240 WL 48 19224 Wi 270 WL 24 9925 Wi 300 WL 48 19226 Wi 330 WL 48 19227 Ws 0 WL 24 9628 Ws 30 WL 48 19229 Ws 60 WL 48 19230 Ws 90 WL 24 9931 Ws 120 WL 48 19232 Ws 150 WL 48 19233 Ws 180 WL 24 9634 Ws 210 WL 48 19235 Ws 240 WL 48 19236 Ws 270 WL 24 9937 Ws 300 WL 48 19238 Ws 330 WL 48 19239 Ev -Y ELY 6040 Eh -Z ELZ 6041 Eh -X ELX 6042 Lm (1) LL 143 Lm (2) LL 144 Lm (3) LL 145 Lm (4) LL 146 Lm (5) LL 147 Lm (6) LL 148 Lm (7) LL 149 Lm (8) LL 150 Lm (9) LL 151 Lm (10) LL 152 Lm (11) LL 153 Lm (12) LL 1
TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334
This report was prepared for American Tower Corporation by
Structural Analysis ReportStructure : 146 ft Monopole
ATC Site Name : CT Chaplin South CT,CT
ATC Site Number : 411216
Engineering Number : 14071468_C3_03
Proposed Carrier : T-MOBILE
Carrier Site Name : CT508//Verizon Chaplin
Carrier Site Number : CT11508F
Site Location : 123 Palmer RoadChaplin, CT 06235-241641.7845, -72.1357
County : Windham
Date : May 3, 2022
Max Usage : 72%
Result : Pass
Prepared By:
Ravi Siddharth RajaCLS
Reviewed By:
Digitally signed by David W Chickering Date: 2022.05.03 16:54:28 -04'00'
Eng. Number 14071468_C3_03May 3, 2022
Page. 2
TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334
Table of Contents
Introduction...................................................................................................................................3Supporting Documents ..................................................................................................................3Analysis ..........................................................................................................................................3Conclusion .....................................................................................................................................3Existing and Reserved Equipment..................................................................................................4Equipment to be Removed ............................................................................................................4Proposed Equipment .....................................................................................................................4Structure Usages............................................................................................................................5Foundations ...................................................................................................................................5Deflection and Sway* ....................................................................................................................5Standard Conditions ......................................................................................................................6Calculations …………………………………………………………..Attached
Eng. Number 14071468_C3_03May 3, 2022
Page. 3
TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334
IntroductionThe purpose of this report is to summarize results of a structural analysis performed on the 146 ft Monopole to reflect the change in loading by T-MOBILE.
Supporting Documents
Tower Drawings EEI Project #12120 Rev. 2, dated November 21, 2003Foundation Drawing EEI Project #12120 Rev. 3, dated December 18, 2003Geotechnical Report GEOServices Project #31-151287M, dated September 8, 2015Mount Analysis ATC Project# 14071468_C8_01, dated April 4, 2022Mount Modifications ATC Project# 14071468_C9_04, dated April 29, 2022
AnalysisThe tower was analyzed using American Tower Corporation’s tower analysis software. This program considers an elastic three-dimensional model and second-order effects per ANSI/TIA-222.
Basic Wind Speed: 120 mph (3-second gust)Basic Wind Speed w/ Ice: 50 mph (3-second gust) w/ 1.00" radial ice concurrentCode: ANSI/TIA-222-H / 2015 IBC / 2018 Connecticut State Building CodeExposure Category: BRisk Category: IITopographic Factor Procedure: Method 1Topographic Category: 1Crest Height (H): 0 ftCrest Length (L): 0 ft Spectral Response: Ss = 0.18, S1 = 0.06Site Class: D - Stiff Soil - Default
ConclusionBased on the analysis results, the structure meets the requirements per the applicable codes listed above. The tower and foundation can support the equipment as described in this report.
If you have any questions or require additional information, please contact American Tower via email at [email protected]. Please include the American Tower site name, site number, and engineering number in the subject line for any questions.
Eng. Number 14071468_C3_03May 3, 2022
Page. 4
TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334
Existing and Reserved Equipment
Elev.1 (ft) Qty Equipment Mount Type Lines Carrier
3 Samsung MT6407-77A
6 Andrew SBNHH-1D65B2 Antel LPA-80063/4CF
148.0
4 Antel LPA-80080/4CF ___3 Samsung B5/B13 RRH-BR04C2 Raycap RC3DC-3315-PF-48147.03 Samsung B2/B66A RRH-BR049
Triangular Low Profile Platform
(18) 1 5/8" Coax(2) 1 5/8" Hybriflex VERIZON WIRELESS
6 Alcatel-Lucent RRH2x50-083 Alcatel-Lucent 1900 MHz 4X45 RRH3 Alcatel-Lucent TD-RRH8x20-25 w/ Solar Shield3 RFS APXVTM14-ALU-I203 Commscope NNVV-65B-R4
137.0
1 Generic GPS
Triangular Platform with Handrails
(4) 1 1/4" HybriflexCable
(7) 1 5/8" CoaxSPRINT NEXTEL
3 CCI OPA65R-BU8D3 CCI DMP65R-BU8D3 Allgon 7770.003 Ericsson RRUS 4449 B5, B123 Ericsson RRUS 4478 B143 Ericsson Radio 8843 - B2 + B66A3 Raycap DC6-48-60-18-8F
128.0
6 Powerwave Allgon LGP21401
Triangular Platform with Handrails
(2) 0.39" (10mm)Fiber Trunk
(6) 0.78" (19.7mm)8 AWG 6
(6) 1 5/8" Coax(3) 2" conduit
AT&T MOBILITY
117.0 3 RFS APXVAARR24_43-U-NA20 Triangular Platform with Handrails - T-MOBILE
3 Fujitsu TA08025-B6043 Fujitsu TA08025-B6053 Commscope FFVV-65B-R2
105.0
1 Raycap RDIDC-9181-PF-48
Triangular Platform with Handrails
(1) 1.60" (40.6mm)Hybrid DISH WIRELESS L.L.C.
63.0 1 Generic GPS Stand-Off (1) 1/2" Coax AT&T MOBILITY
Equipment to be Removed
Elev.1 (ft) Qty Equipment Mount Type Lines Carrier
3 Ericsson KRY 112 144/13 Ericsson KRY 112 489/23 RFS APXV18-206517
116.0
3 Ericsson Radio 4449 B12,B71
-(1) 1 5/8" (1.63"-
41.3mm) Fiber(12) 1 5/8" Coax
T-MOBILE
Proposed EquipmentElev.1 (ft) Qty Equipment Mount Type Lines Carrier
3 Ericsson Radio 4449 B71 B85A3 Ericsson 4460 BAND 2/253 Commscope VV-65A-R1
117.0
3 Ericsson AIR 6419 B41
Triangular Platform with Handrails
(1) 1 1/4" HybriflexCable
(2) 1.99" (50.7mm)Hybrid
T-MOBILE
1 Contracted elevations are shown for appurtenances within contracted installation tolerances. Appurtenances outside of contract limits are shown at installed elevations.
Install proposed lines inside the pole shaft.
Eng. Number 14071468_C3_03May 3, 2022
Page. 5
TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334
Structure Usages
Structural Component Controlling Usage Pass/Fail
Anchor Bolts 55% PassShaft 67% Pass
Base Plate 51% Pass
Foundations
ReactioComponent Original Design Reactions
Factored Design Reactions* Analysis Reactions % of Design
Moment (Kips-Ft) 3157.8 4263.0 3064.9 72%Shear (Kips) 30.5 41.2 27.7 67%
* The design reactions are factored by 1.35 per ANSI/TIA-222-H, Sec. 15.6.2
The structure base reactions resulting from this analysis are acceptable when compared to those shown on the original structure drawings, therefore no modification or reinforcement of the foundation will be required.
Deflection and Sway*
AntennaElevation
(ft)Antenna Carrier Deflection
(ft)
Sway (Rotation)
(°)Ericsson Radio 4449 B71 B85A
Ericsson 4460 BAND 2/25RFS APXVAARR24_43-U-NA20
Ericsson AIR 6419 B41117.0
Commscope VV-65A-R1
T-MOBILE 1.040 1.020
*Deflection and Sway was evaluated considering a design wind speed of 60 mph (3-Second Gust) per ANSI/TIA-222-H
Eng. Number 14071468_C3_03May 3, 2022
Page. 6
TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334
Standard Conditions
All engineering services performed by A.T. Engineering Service, PLLC are prepared on the basis that the information used is current and correct. This information may consist of, but is not limited to the following:
• Information supplied by the client regarding antenna, mounts and feed line loading
• Information from drawings, design and analysis documents, and field notes in the possession of A.T. Engineering Service, PLLC
It is the responsibility of the client to ensure that the information provided to A.T. Engineering Service, PLLC and used in the performance of our engineering services is correct and complete.
All assets of American Tower Corporation, its affiliates, and subsidiaries (collectively “American Tower”) are inspected at regular intervals. Based upon these inspections and in the absence of information to the contrary, American Tower assumes that all structures were constructed in accordance with the drawings and specifications.
Unless explicitly agreed by both the client and A.T. Engineering Service, PLLC, all services will be performed in accordance with the current revision of ANSI/TIA-222.
All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. A.T. Engineering Service, PLLC is not responsible for the conclusions, opinions and recommendations made by others based on the information supplied herein.
JOB INFORMATIONAsset : 411216, CT Chaplin South CT Height : 146 ftClient : T-MOBILE Base Width : 54.5Code : ANSI/TIA-222-H Shape : 18 Sides
© 2007 - 2020 by ATC LLC. All rights reserved. Page 1 of 2 Model ID : 28148 Scenario : 208553 5/3/2022 15:08:12
SITE PARAMETERSNominal Wind: 120 mph wind with no ice Topo Category: 1
Ice Wind: 50 mph wind with 1" radial Topo Method: Method 1
Base Elev (ft): 0.00 Taper : 0.22000(In/ft) Topo Feature:
Structure Class: II Exposure : B Ss : 0.185 S1 : 0.055
SECTION PROPERTIES
ShaftSection
Length(ft)
Diameter (in)
Thick(in)
Joint Type
OverlapLength
(in) Shape
Steel Grade
(ksi)
Across Flats
Top Bottom
1 53.080 42.82 54.50 0.375 0.000 18 Sides 652 51.540 33.46 44.80 0.312 Slip Joint 74.000 18 Sides 653 52.463 23.50 35.04 0.250 Slip Joint 59.000 18 Sides 65
DISCRETE APPURTENANCE
AttachElev (ft)
ForceElev (ft) Qty Description
146.0 147.0 3 Samsung B2/B66A RRH-BR049146.0 147.0 3 Samsung B5/B13 RRH-BR04C146.0 147.0 2 Raycap RC3DC-3315-PF-48146.0 148.0 3 Samsung MT6407-77A146.0 148.0 4 Antel LPA-80080/4CF ___146.0 148.0 2 Antel LPA-80063/4CF146.0 148.0 6 Andrew SBNHH-1D65B146.0 146.0 1 Generic Flat Low Profile Platf137.5 137.5 1 Generic Round Platform with Ha137.0 137.0 1 Generic GPS137.0 137.0 6 Alcatel-Lucent RRH2x50-08137.0 137.0 3 Alcatel-Lucent 1900 MHz 4X45 R137.0 137.0 3 Alcatel-Lucent TD-RRH8x20-25 w137.0 137.0 3 RFS APXVTM14-ALU-I20137.0 137.0 3 Commscope NNVV-65B-R4128.0 126.0 6 Powerwave Allgon LGP21401128.0 126.0 3 Raycap DC6-48-60-18-8F128.0 128.0 3 Ericsson Radio 8843 - B2 + B66128.0 128.0 3 Ericsson RRUS 4478 B14128.0 128.0 3 Ericsson RRUS 4449 B5, B12128.0 126.0 3 Allgon 7770.00128.0 128.0 1 Generic Mount Reinforcement128.0 128.0 3 CCI DMP65R-BU8D128.0 128.0 3 CCI OPA65R-BU8D128.0 128.0 1 Generic Round Platform with Ha117.0 117.0 3 Ericsson Radio 4449 B71 B85A117.0 117.0 3 Ericsson 4460 BAND 2/25117.0 117.0 3 Commscope VV-65A-R1117.0 117.0 3 Ericsson AIR 6419 B41117.0 117.0 3 RFS APXVAARR24_43-U-NA20116.0 116.0 2 Generic Mount Reinforcement116.0 116.0 1 Generic Round Platform with Ha105.0 105.0 1 Raycap RDIDC-9181-PF-48105.0 105.0 3 Fujitsu TA08025-B605105.0 105.0 3 Fujitsu TA08025-B604105.0 105.0 3 Commscope FFVV-65B-R2105.0 105.0 1 Generic Round Platform with Ha75.0 75.0 1 Generic Flat Stand-Off63.0 63.0 1 Generic GPS63.0 63.0 1 Generic Flat Stand-Off
JOB INFORMATIONAsset : 411216, CT Chaplin South CT Height : 146 ftClient : T-MOBILE Base Width : 54.5Code : ANSI/TIA-222-H Shape : 18 Sides
© 2007 - 2020 by ATC LLC. All rights reserved. Page 2 of 2 Model ID : 28148 Scenario : 208553 5/3/2022 15:08:12
LINEAR APPURTENANCEElev
From (ft)Elev
To (ft) Description Exp To Wind
0.0 149.0 1 5/8" Coax No0.0 148.0 1 5/8" Coax No0.0 147.0 1 5/8" Hybriflex No0.0 137.0 1 5/8" Coax No0.0 137.0 1 1/4" Hybriflex Cable No0.0 128.0 2" conduit No0.0 128.0 1 5/8" Coax No0.0 128.0 0.78" (19.7mm) 8 AWG 6 No0.0 128.0 0.39" (10mm) Fiber Trunk No0.0 117.0 1.99" (50.7mm) Hybrid No0.0 117.0 1 1/4" Hybriflex Cable No0.0 105.0 1.60" (40.6mm) Hybrid No0.0 63.0 1/2" Coax Yes
LOAD CASES1.2D + 1.0W 120 mph wind with no ice0.9D + 1.0W 120 mph wind with no ice1.2D + 1.0Di + 1.0Wi 50 mph wind with 1" radial ice1.2D + 1.0Ev + 1.0Eh Seismic0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL)1.0D + 1.0W 60 mph Wind with No Ice
REACTIONS
Load CaseMoment
(kip-ft)Shear(Kip)
Axial(Kip)
1.2D + 1.0W 3064.77 27.74 56.180.9D + 1.0W 3016.64 27.72 42.131.2D + 1.0Di + 1.0Wi 785.58 7.19 74.181.2D + 1.0Ev + 1.0Eh 177.40 1.41 56.400.9D - 1.0Ev + 1.0Eh 173.88 1.41 39.151.0D + 1.0W 679.02 6.20 46.85
DISH DEFLECTIONS
Load CaseAttach
Elev (ft)Deflection
(in)Rotation
(deg)
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 1 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
ANALYSIS PARAMETERS
Location: Windham County,CT Height: 146 ft
Type and Shape: Taper, 18 Sides Base Diameter: 54.50 in
Manufacturer: EEI Top Diameter: 23.50 in
Kd (non-service): 0.95 Taper: 0.2200 in/ft
Ke: 0.98 Rotation: 0.000o
ICE & WIND PARAMETERS
Exposure Category: B Design Wind Speed w/o Ice: 120 mph
Risk Category: II Design Wind Speed w/Ice: 50 mph
Topo Factor Procedure: Method 1 Operational Wind Speed: 60 mph
Topographic Category: 1 Design Ice Thickness: 1.00 in
Crest Height: 0 ft HMSL: 505.00 ft
SEISMIC PARAMETERS
Analysis Method: Equivalent Lateral Force Method
Site Class: D - Stiff Soil Period Based on Rayleigh Method (sec): 2.71
TL (sec): 6 P: 1 Cs: 0.030
Ss: 0.185 S1: 0.055 Cs Max: 0.030
Fa: 1.600 Fv: 2.400 Cs Min: 0.030
Sds: 0.197 Sd1: 0.088
LOAD CASES
1.2D + 1.0W 120 mph wind with no ice 0.9D + 1.0W 120 mph wind with no ice 1.2D + 1.0Di + 1.0Wi 50 mph wind with 1" radial ice 1.2D + 1.0Ev + 1.0Eh Seismic 0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL) 1.0D + 1.0W 60 mph Wind with No Ice
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 2 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
SHAFT SECTION PROPERTIES
Bottom.
Top
Sect Info
Length(ft)
Thick(in)
Fy(ksi)
JointType
Slip Joint
len (in)Weight
(lb)Dia (in)
Elev(ft)
Area (in2)
Ix(in4)
W/t Ratio
D/t Ratio
Dia (in)
Elev (in)
Area (in2)
Ix(in4)
W/tRatio
D/t Ratio
Taper (in/ft)
1-18 53.08 0.3750 65 0.00 10,380 54.50 0.000 64.42 23,843.5 24.22 145.33 42.82 53.08 50.52 11,499.1 18.72 114.19 0.22002-18 51.54 0.3125 65 Slip 74.00 6,753 44.80 46.910 44.13 11,035.0 23.87 143.37 33.46 98.45 32.88 4,564.6 17.47 107.08 0.22003-18 52.46 0.2500 65 Slip 59.00 4,111 35.04 93.537 27.61 4,222.5 23.31 140.17 23.50 146.00 18.45 1,259.8 15.16 94.00 0.2200
Shaft Weight 21,244DISCRETE APPURTENANCE PROPERTIES
AttachElev
(ft) Description Qty Ka
VertEcc(ft)
. No Ice . . Ice .Weight
(lb)EPAa
(sf)Orientation
FactorWeight
(lb)EPAa
(sf)Orientation
Factor
146.00 Samsung MT6407-77A 3 0.80 2.000 81.60 4.709 0.61 149.48 5.721 0.61146.00 Samsung B5/B13 RRH-BR04C 3 0.80 1.000 70.30 1.875 0.50 108.40 2.476 0.50146.00 Samsung B2/B66A RRH-BR049 3 0.80 1.000 84.40 1.875 0.50 126.89 2.476 0.50146.00 Raycap RC3DC-3315-PF-48 2 0.80 1.000 32.00 3.781 0.50 104.86 4.663 0.50146.00 Generic Flat Low Profile Platf 1 1.00 0.000 1875.00 26.100 1.00 2414.37 38.815 1.00146.00 Antel LPA-80080/4CF ___ 4 0.80 2.000 12.00 5.399 0.62 95.71 3.166 0.62146.00 Antel LPA-80063/4CF 2 0.80 2.000 20.00 6.142 0.82 149.92 6.819 0.82146.00 Andrew SBNHH-1D65B 6 0.80 2.000 50.70 8.173 0.69 167.56 10.058 0.69137.50 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3572.46 43.385 1.00137.00 RFS APXVTM14-ALU-I20 3 0.75 0.000 56.20 6.342 0.66 147.29 7.783 0.66137.00 Commscope NNVV-65B-R4 3 0.75 0.000 77.40 12.271 0.64 243.62 14.126 0.64137.00 Alcatel-Lucent TD-RRH8x20-25 w 3 0.75 0.000 70.00 4.046 0.50 132.52 4.924 0.50137.00 Alcatel-Lucent 1900 MHz 4X45 R 3 0.75 0.000 60.00 2.322 0.50 113.31 3.037 0.50137.00 Alcatel-Lucent RRH2x50-08 6 0.75 0.000 52.90 1.701 0.50 92.10 2.272 0.50137.00 Generic GPS 1 1.00 0.000 10.00 0.900 1.00 29.36 1.323 1.00128.00 CCI OPA65R-BU8D 3 0.75 0.000 76.50 18.089 0.63 302.96 20.514 0.63128.00 CCI DMP65R-BU8D 3 0.75 0.000 95.70 17.871 0.63 318.92 20.291 0.63128.00 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3563.75 43.254 1.00128.00 Generic Mount Reinforcement 1 1.00 0.000 200.00 7.500 1.00 327.10 12.417 1.00128.00 Allgon 7770.00 3 0.75 -2.000 35.00 5.508 0.65 116.75 6.183 0.65128.00 Ericsson RRUS 4449 B5, B12 3 0.75 0.000 71.00 1.969 0.50 113.33 2.582 0.50128.00 Ericsson RRUS 4478 B14 3 0.75 0.000 59.90 1.842 0.50 96.21 2.431 0.50128.00 Ericsson Radio 8843 - B2 + B66 3 0.75 0.000 71.90 1.650 0.50 112.36 2.206 0.50128.00 Raycap DC6-48-60-18-8F 3 0.75 -2.000 20.00 1.260 0.50 54.58 1.692 0.50128.00 Powerwave Allgon LGP21401 6 0.75 -2.000 14.10 1.104 0.50 30.49 1.573 0.50117.00 RFS APXVAARR24_43-U-NA20 3 0.75 0.000 127.90 20.243 0.63 383.62 22.659 0.63117.00 Ericsson AIR 6419 B41 3 0.75 0.000 83.30 6.322 0.63 181.88 7.424 0.63117.00 Commscope VV-65A-R1 3 0.75 0.000 23.80 5.928 0.63 100.28 7.308 0.63117.00 Ericsson 4460 BAND 2/25 3 0.75 0.000 109.00 2.564 0.50 166.57 3.250 0.50117.00 Ericsson Radio 4449 B71 B85A 3 0.75 0.000 75.00 1.650 0.50 114.17 2.203 0.50116.00 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3554.12 43.108 1.00116.00 Generic Mount Reinforcement 2 1.00 0.000 200.00 7.500 1.00 325.95 12.373 1.00105.00 Commscope FFVV-65B-R2 3 0.75 0.000 70.80 12.271 0.64 232.41 14.074 0.64105.00 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3541.61 42.920 1.00105.00 Raycap RDIDC-9181-PF-48 1 0.75 0.000 21.90 1.867 0.50 58.50 2.446 0.50105.00 Fujitsu TA08025-B604 3 0.75 0.000 63.90 1.962 0.50 101.40 2.554 0.50105.00 Fujitsu TA08025-B605 3 0.75 0.000 75.00 1.962 0.50 115.29 2.554 0.5075.00 Generic Flat Stand-Off 1 1.00 0.000 187.50 6.300 1.00 270.26 8.236 1.0063.00 Generic Flat Stand-Off 1 1.00 0.000 187.50 6.300 1.00 268.91 8.204 1.0063.00 Generic GPS 1 1.00 0.000 10.00 0.900 1.00 27.88 1.291 1.00
Totals Num Loadings: 40 105 18,425.90 31,510.24LINEAR APPURTENANCE PROPERTIES
Load Case Azimuth (deg) : 90.00
ElevFrom
(ft)
ElevTo(ft) Qty Description
CoaxDia(in)
CoaxWt
(lb/ft) Flat
MaxCoax/
Row
DistBetweenRows(in)
DistBetweenCols(in)
Azimuth (deg)
DistFromFace
(in)Exposed To Wind Carrier
0.00 149.00 6 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N VERIZON WIREL0.00 148.00 12 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N VERIZON WIREL0.00 147.00 2 1 5/8" Hybriflex 1.98 1.3 N 0 0 0 0 0 N VERIZON WIREL0.00 137.00 7 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N SPRINT NEXTEL0.00 137.00 4 1 1/4" Hybriflex Cabl 1.54 1 N 0 0 0 0 0 N SPRINT NEXTEL0.00 128.00 6 0.78" (19.7mm) 8 AWG 0.78 0.59 N 0 0 0 0 0 N AT&T MOBILITY
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 3 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
ElevFrom
(ft)
ElevTo(ft) Qty Description
CoaxDia(in)
CoaxWt
(lb/ft) Flat
MaxCoax/
Row
DistBetweenRows(in)
DistBetweenCols(in)
Azimuth (deg)
DistFromFace
(in)Exposed To Wind Carrier
0.00 128.00 6 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N AT&T MOBILITY0.00 128.00 3 2" conduit 2.38 3.65 N 0 0 0 0 0 N AT&T MOBILITY0.00 128.00 2 0.39" (10mm) Fiber Tr 0.39 0.06 N 0 0 0 0 0 N AT&T MOBILITY0.00 117.00 2 1.99" (50.7mm) Hybrid 1.99 1.9 N 0 0 0 0 0 N T-MOBILE0.00 117.00 1 1 1/4" Hybriflex Cabl 1.54 1 N 0 0 0 0 0 N T-MOBILE0.00 105.00 1 1.60" (40.6mm) Hybrid 1.6 2.34 N 1 0 0 0 0 N DISH WIRELESS0.00 63.00 1 1/2" Coax 0.63 0.15 N 1 1 1 180 1 Y AT&T MOBILITY
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 4 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
SEGMENT PROPERTIES(Max Len: 5.ft) .
Seg TopElev (ft)
Description Thick(in)
Flat Dia(in)
Area(in2)
Ix(in4)
W/t Ratio
D/t Ratio
F'y (ksi)
S(in3)
Z(in3)
Weight (lb)
0.00 0.3750 54.500 64.420 23,843.50 24.22 145.33 72.9 861.7 0.0 0.0 5.00 0.3750 53.400 63.111 22,418.80 23.70 142.40 73.5 826.9 0.0 1,084.9
10.00 0.3750 52.300 61.801 21,052.10 23.18 139.47 74.1 792.8 0.0 1,062.6 15.00 0.3750 51.199 60.492 19,742.10 22.66 136.53 74.7 759.5 0.0 1,040.3 20.00 0.3750 50.099 59.182 18,487.60 22.15 133.60 75.4 726.8 0.0 1,018.1 25.00 0.3750 48.999 57.873 17,287.30 21.63 130.66 76 694.9 0.0 995.8 30.00 0.3750 47.899 56.563 16,140.20 21.11 127.73 76.6 663.7 0.0 973.5 35.00 0.3750 46.799 55.254 15,045.00 20.59 124.80 77.2 633.2 0.0 951.2 40.00 0.3750 45.698 53.944 14,000.50 20.08 121.86 77.8 603.4 0.0 928.9 45.00 0.3750 44.598 52.635 13,005.50 19.56 118.93 78.4 574.4 0.0 906.7 46.91 Bot - Section 2 0.3750 44.177 52.134 12,637.60 19.36 117.81 78.6 563.4 0.0 341.1 50.00 0.3750 43.498 51.325 12,058.80 19.04 115.99 79 546.0 0.0 1,003.3 53.08 Top - Section 1 0.3125 43.445 42.781 10,055.80 23.10 139.03 74.2 455.9 0.0 985.6 55.00 0.3125 43.023 42.362 9,763.20 22.86 137.67 74.5 447.0 0.0 278.1 60.00 0.3125 41.923 41.271 9,028.00 22.24 134.15 75.2 424.2 0.0 711.5 63.00 0.3125 41.263 40.616 8,605.10 21.87 132.04 75.7 410.8 0.0 418.0 65.00 0.3125 40.822 40.179 8,330.70 21.62 130.63 76 401.9 0.0 274.9 70.00 0.3125 39.722 39.088 7,670.20 21.00 127.11 76.7 380.3 0.0 674.3 75.00 0.3125 38.622 37.997 7,045.60 20.38 123.59 77.4 359.3 0.0 655.8 80.00 0.3125 37.522 36.906 6,455.80 19.76 120.07 78.2 338.9 0.0 637.2 85.00 0.3125 36.422 35.815 5,899.90 19.14 116.55 78.9 319.1 0.0 618.6 90.00 0.3125 35.321 34.723 5,376.90 18.52 113.03 79.6 299.8 0.0 600.1 93.54 Bot - Section 3 0.3125 34.543 33.951 5,026.30 18.08 110.54 80.1 286.6 0.0 413.2 95.00 0.3125 34.221 33.632 4,885.80 17.90 109.51 80.3 281.2 0.0 305.1 98.45 Top - Section 2 0.2500 33.961 26.749 3,840.70 22.54 135.85 74.9 222.7 0.0 708.6
100.00 0.2500 33.621 26.479 3,725.60 22.30 134.48 75.2 218.3 0.0 140.1 105.00 0.2500 32.521 25.606 3,369.10 21.53 130.08 76.1 204.0 0.0 443.1 110.00 0.2500 31.421 24.733 3,036.20 20.75 125.68 77 190.3 0.0 428.2 115.00 0.2500 30.321 23.860 2,725.90 19.97 121.28 77.9 177.1 0.0 413.4 116.00 0.2500 30.100 23.685 2,666.50 19.82 120.40 78.1 174.5 0.0 80.9 117.00 0.2500 29.880 23.511 2,607.90 19.66 119.52 78.3 171.9 0.0 80.3 120.00 0.2500 29.220 22.987 2,437.50 19.20 116.88 78.8 164.3 0.0 237.3 125.00 0.2500 28.120 22.114 2,170.20 18.42 112.48 79.7 152.0 0.0 383.7 128.00 0.2500 27.460 21.590 2,019.60 17.96 109.84 80.3 144.9 0.0 223.1 130.00 0.2500 27.020 21.241 1,923.20 17.65 108.08 80.6 140.2 0.0 145.7 135.00 0.2500 25.920 20.368 1,695.70 16.87 103.68 81.6 128.9 0.0 354.0 137.00 0.2500 25.480 20.019 1,610.00 16.56 101.92 81.9 124.5 0.0 137.4 137.50 0.2500 25.370 19.932 1,589.00 16.48 101.48 82 123.4 0.0 34.0 140.00 0.2500 24.820 19.495 1,486.90 16.09 99.28 82.5 118.0 0.0 167.7 145.00 0.2500 23.719 18.622 1,295.90 15.32 94.88 82.6 107.6 0.0 324.3 146.00 0.2500 23.499 18.448 1,259.80 15.16 94.00 82.6 105.6 0.0 63.1
Totals: 21,243.7
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 5 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Load Case: 1.2D + 1.0W 120 mph wind with no ice 24 IterationsGust Response Factor: 1.10Dead load Factor: 1.20Wind Load Factor: 1.00
CALCULATED FORCES
SegElev
(ft)
PuFY (-)(kips)
VuFX (-)(kips)
TuMY
(ft-kips)
MuMZ
(ft-kips)
MuMX
(ft-kips)
ResultantMoment(ft-kips)
PhiPn
(kips)
PhiVn
(kips)
PhiTn
(ft-kips)
PhiMn
(ft-kips)
TotalDeflect
(in)Rotation
(deg) Ratio
0.00 -56.18 -27.74 0.00 -3,064.8 0.00 3,064.77 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.6645.00 -54.47 -27.47 0.00 -2,926.1 0.00 2,926.07 4,176.31 1,107.59 5,304.49 4,560.00 0.1 -0.18 0.655
10.00 -52.79 -27.21 0.00 -2,788.7 0.00 2,788.71 4,123.50 1,084.61 5,086.68 4,408.26 0.38 -0.36 0.64615.00 -51.13 -26.94 0.00 -2,652.7 0.00 2,652.69 4,069.26 1,061.63 4,873.43 4,257.44 0.86 -0.54 0.63620.00 -49.50 -26.68 0.00 -2,518.0 0.00 2,517.99 4,013.58 1,038.65 4,664.74 4,107.62 1.53 -0.73 0.62625.00 -47.91 -26.41 0.00 -2,384.6 0.00 2,384.62 3,956.47 1,015.67 4,460.63 3,958.90 2.39 -0.92 0.61530.00 -46.33 -26.14 0.00 -2,252.6 0.00 2,252.56 3,897.92 992.68 4,261.08 3,811.39 3.46 -1.11 0.60435.00 -44.79 -25.86 0.00 -2,121.8 0.00 2,121.85 3,837.94 969.70 4,066.09 3,665.19 4.72 -1.3 0.59140.00 -43.28 -25.57 0.00 -1,992.5 0.00 1,992.53 3,776.52 946.72 3,875.67 3,520.38 6.19 -1.5 0.57845.00 -41.81 -25.35 0.00 -1,864.7 0.00 1,864.67 3,713.67 923.74 3,689.82 3,377.07 7.86 -1.69 0.56446.91 -41.24 -25.20 0.00 -1,816.2 0.00 1,816.17 3,689.24 914.95 3,619.91 3,322.65 8.56 -1.77 0.55950.00 -39.79 -24.98 0.00 -1,738.4 0.00 1,738.40 3,649.39 900.76 3,508.54 3,235.36 9.74 -1.89 0.54953.08 -38.38 -24.79 0.00 -1,661.5 0.00 1,661.46 2,857.95 750.80 2,924.98 2,537.94 11.01 -2.02 0.66955.00 -37.86 -24.59 0.00 -1,613.9 0.00 1,613.86 2,840.65 743.45 2,867.97 2,497.68 11.83 -2.09 0.66160.00 -36.62 -24.32 0.00 -1,490.9 0.00 1,490.92 2,794.59 724.30 2,722.13 2,393.44 14.15 -2.32 0.63763.00 -35.66 -23.91 0.00 -1,418.0 0.00 1,417.95 2,766.27 712.81 2,636.46 2,331.31 15.65 -2.46 0.62265.00 -35.15 -23.70 0.00 -1,370.1 0.00 1,370.13 2,747.10 705.15 2,580.10 2,290.09 16.7 -2.55 0.61270.00 -33.95 -23.37 0.00 -1,251.6 0.00 1,251.63 2,698.18 686.00 2,441.88 2,187.75 19.49 -2.77 0.58675.00 -32.56 -22.80 0.00 -1,134.8 0.00 1,134.81 2,647.83 666.85 2,307.46 2,086.52 22.52 -3 0.55780.00 -31.41 -22.45 0.00 -1,020.8 0.00 1,020.84 2,596.04 647.70 2,176.84 1,986.48 25.77 -3.21 0.52785.00 -30.29 -22.10 0.00 -908.6 0.00 908.59 2,542.81 628.54 2,050.03 1,887.74 29.25 -3.43 0.49490.00 -29.21 -21.78 0.00 -798.1 0.00 798.11 2,488.15 609.39 1,927.03 1,790.40 32.95 -3.63 0.45993.54 -28.46 -21.59 0.00 -721.1 0.00 721.07 2,448.63 595.85 1,842.32 1,722.45 35.69 -3.77 0.43295.00 -27.98 -21.41 0.00 -689.5 0.00 689.47 2,432.06 590.24 1,807.83 1,694.56 36.86 -3.83 0.42098.45 -26.88 -21.19 0.00 -615.5 0.00 615.53 1,802.83 469.45 1,429.40 1,251.05 39.68 -3.96 0.509
100.00 -26.59 -20.98 0.00 -582.8 0.00 582.76 1,791.36 464.71 1,400.69 1,230.45 40.97 -4.02 0.490105.00 -22.06 -18.45 0.00 -477.9 0.00 477.86 1,753.33 449.39 1,309.86 1,164.33 45.29 -4.22 0.425110.00 -21.22 -18.08 0.00 -385.6 0.00 385.61 1,713.87 434.07 1,222.08 1,099.03 49.81 -4.41 0.365115.00 -20.41 -17.83 0.00 -295.2 0.00 295.20 1,672.98 418.74 1,137.35 1,034.64 54.51 -4.57 0.299116.00 -16.91 -15.84 0.00 -277.4 0.00 277.37 1,664.63 415.68 1,120.76 1,021.88 55.47 -4.6 0.283117.00 -15.40 -13.59 0.00 -261.5 0.00 261.54 1,656.22 412.62 1,104.30 1,009.16 56.43 -4.62 0.270120.00 -14.95 -13.30 0.00 -220.8 0.00 220.76 1,630.65 403.42 1,055.65 971.26 59.36 -4.7 0.238125.00 -14.22 -12.98 0.00 -154.3 0.00 154.26 1,586.89 388.10 977.01 908.99 64.34 -4.81 0.180128.00 -9.28 -8.22 0.00 -115.3 0.00 115.32 1,559.94 378.91 931.28 872.20 67.38 -4.87 0.139130.00 -9.05 -7.98 0.00 -98.9 0.00 98.87 1,541.69 372.78 901.40 847.93 69.42 -4.9 0.123135.00 -8.48 -7.70 0.00 -59.0 0.00 58.99 1,495.06 357.46 828.84 788.18 74.58 -4.95 0.081137.00 -7.06 -5.90 0.00 -43.6 0.00 43.58 1,476.01 351.33 800.67 764.66 76.66 -4.97 0.062137.50 -4.12 -4.43 0.00 -40.6 0.00 40.63 1,471.21 349.80 793.70 758.82 77.18 -4.97 0.057140.00 -3.89 -4.18 0.00 -29.6 0.00 29.55 1,447.00 342.14 759.33 729.83 79.78 -4.99 0.043145.00 -3.41 -3.95 0.00 -8.7 0.00 8.67 1,383.54 326.82 692.86 666.26 85.01 -5.01 0.016146.00 0.00 -3.64 0.00 -4.7 0.00 4.72 1,370.57 323.76 679.93 653.76 86.06 -5.01 0.007
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 6 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Load Case: 0.9D + 1.0W 120 mph wind with no ice 24 IterationsGust Response Factor: 1.10Dead load Factor: 0.90Wind Load Factor: 1.00
CALCULATED FORCES
SegElev
(ft)
PuFY (-)(kips)
VuFX (-)(kips)
TuMY
(ft-kips)
MuMZ
(ft-kips)
MuMX
(ft-kips)
ResultantMoment(ft-kips)
PhiPn
(kips)
PhiVn
(kips)
PhiTn
(ft-kips)
PhiMn
(ft-kips)
TotalDeflect
(in)Rotation
(deg) Ratio
0.00 -42.13 -27.72 0.00 -3,016.6 0.00 3,016.64 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.6515.00 -40.82 -27.41 0.00 -2,878.1 0.00 2,878.06 4,176.31 1,107.59 5,304.49 4,560.00 0.09 -0.18 0.642
10.00 -39.54 -27.10 0.00 -2,741.0 0.00 2,741.03 4,123.50 1,084.61 5,086.68 4,408.26 0.37 -0.35 0.63215.00 -38.28 -26.79 0.00 -2,605.6 0.00 2,605.56 4,069.26 1,061.63 4,873.43 4,257.44 0.84 -0.53 0.62220.00 -37.04 -26.49 0.00 -2,471.6 0.00 2,471.61 4,013.58 1,038.65 4,664.74 4,107.62 1.5 -0.72 0.61225.00 -35.82 -26.19 0.00 -2,339.2 0.00 2,339.18 3,956.47 1,015.67 4,460.63 3,958.90 2.35 -0.9 0.60130.00 -34.63 -25.88 0.00 -2,208.3 0.00 2,208.26 3,897.92 992.68 4,261.08 3,811.39 3.4 -1.09 0.58935.00 -33.45 -25.57 0.00 -2,078.8 0.00 2,078.84 3,837.94 969.70 4,066.09 3,665.19 4.64 -1.28 0.57740.00 -32.30 -25.25 0.00 -1,951.0 0.00 1,950.98 3,776.52 946.72 3,875.67 3,520.38 6.08 -1.47 0.56345.00 -31.19 -25.01 0.00 -1,824.7 0.00 1,824.74 3,713.67 923.74 3,689.82 3,377.07 7.72 -1.66 0.54946.91 -30.76 -24.84 0.00 -1,776.9 0.00 1,776.89 3,689.24 914.95 3,619.91 3,322.65 8.41 -1.74 0.54450.00 -29.66 -24.62 0.00 -1,700.2 0.00 1,700.21 3,649.39 900.76 3,508.54 3,235.36 9.57 -1.86 0.53453.08 -28.59 -24.42 0.00 -1,624.4 0.00 1,624.39 2,857.95 750.80 2,924.98 2,537.94 10.81 -1.98 0.65155.00 -28.19 -24.19 0.00 -1,577.5 0.00 1,577.51 2,840.65 743.45 2,867.97 2,497.68 11.62 -2.05 0.64360.00 -27.25 -23.91 0.00 -1,456.6 0.00 1,456.55 2,794.59 724.30 2,722.13 2,393.44 13.89 -2.28 0.61963.00 -26.52 -23.49 0.00 -1,384.8 0.00 1,384.82 2,766.27 712.81 2,636.46 2,331.31 15.36 -2.41 0.60565.00 -26.13 -23.25 0.00 -1,337.8 0.00 1,337.84 2,747.10 705.15 2,580.10 2,290.09 16.39 -2.5 0.59570.00 -25.21 -22.90 0.00 -1,221.6 0.00 1,221.58 2,698.18 686.00 2,441.88 2,187.75 19.13 -2.72 0.56975.00 -24.16 -22.31 0.00 -1,107.1 0.00 1,107.10 2,647.83 666.85 2,307.46 2,086.52 22.09 -2.93 0.54180.00 -23.29 -21.95 0.00 -995.5 0.00 995.54 2,596.04 647.70 2,176.84 1,986.48 25.27 -3.15 0.51185.00 -22.44 -21.58 0.00 -885.8 0.00 885.81 2,542.81 628.54 2,050.03 1,887.74 28.68 -3.35 0.47990.00 -21.61 -21.26 0.00 -777.9 0.00 777.90 2,488.15 609.39 1,927.03 1,790.40 32.3 -3.55 0.44493.54 -21.05 -21.07 0.00 -702.7 0.00 702.71 2,448.63 595.85 1,842.32 1,722.45 34.98 -3.69 0.41895.00 -20.68 -20.88 0.00 -671.9 0.00 671.89 2,432.06 590.24 1,807.83 1,694.56 36.12 -3.75 0.40698.45 -19.86 -20.67 0.00 -599.8 0.00 599.77 1,802.83 469.45 1,429.40 1,251.05 38.88 -3.88 0.492
100.00 -19.63 -20.45 0.00 -567.8 0.00 567.81 1,791.36 464.71 1,400.69 1,230.45 40.15 -3.93 0.474105.00 -16.26 -17.98 0.00 -465.6 0.00 465.58 1,753.33 449.39 1,309.86 1,164.33 44.37 -4.13 0.411110.00 -15.62 -17.61 0.00 -375.7 0.00 375.67 1,713.87 434.07 1,222.08 1,099.03 48.8 -4.31 0.353115.00 -15.01 -17.37 0.00 -287.6 0.00 287.61 1,672.98 418.74 1,137.35 1,034.64 53.39 -4.46 0.289116.00 -12.42 -15.45 0.00 -270.2 0.00 270.24 1,664.63 415.68 1,120.76 1,021.88 54.33 -4.49 0.273117.00 -11.33 -13.24 0.00 -254.8 0.00 254.79 1,656.22 412.62 1,104.30 1,009.16 55.27 -4.52 0.260120.00 -10.99 -12.95 0.00 -215.1 0.00 215.08 1,630.65 403.42 1,055.65 971.26 58.14 -4.6 0.229125.00 -10.44 -12.64 0.00 -150.3 0.00 150.34 1,586.89 388.10 977.01 908.99 63.01 -4.7 0.173128.00 -6.81 -8.00 0.00 -112.4 0.00 112.42 1,559.94 378.91 931.28 872.20 65.98 -4.76 0.134130.00 -6.65 -7.76 0.00 -96.4 0.00 96.43 1,541.69 372.78 901.40 847.93 67.97 -4.79 0.118135.00 -6.22 -7.49 0.00 -57.6 0.00 57.65 1,495.06 357.46 828.84 788.18 73.01 -4.84 0.078137.00 -5.19 -5.73 0.00 -42.7 0.00 42.66 1,476.01 351.33 800.67 764.66 75.04 -4.86 0.060137.50 -3.01 -4.33 0.00 -39.8 0.00 39.80 1,471.21 349.80 793.70 758.82 75.55 -4.86 0.055140.00 -2.84 -4.08 0.00 -29.0 0.00 28.98 1,447.00 342.14 759.33 729.83 78.1 -4.88 0.042145.00 -2.49 -3.86 0.00 -8.6 0.00 8.59 1,383.54 326.82 692.86 666.26 83.21 -4.9 0.015146.00 0.00 -3.64 0.00 -4.7 0.00 4.72 1,370.57 323.76 679.93 653.76 84.24 -4.9 0.007
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 7 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Load Case: 1.2D + 1.0Di + 1.0Wi 50 mph wind with 1" radial ice 24 IterationsGust Response Factor: 1.10 Ice Dead Load Factor 1.00Dead load Factor: 1.20 Ice Importance Factor 1.00Wind Load Factor: 1.00
CALCULATED FORCES
SegElev
(ft)
PuFY (-)(kips)
VuFX (-)(kips)
TuMY
(ft-kips)
MuMZ
(ft-kips)
MuMX
(ft-kips)
ResultantMoment(ft-kips)
PhiPn
(kips)
PhiVn
(kips)
PhiTn
(ft-kips)
PhiMn
(ft-kips)
TotalDeflect
(in)Rotation
(deg) Ratio
0.00 -74.18 -7.19 0.00 -785.6 0.00 785.58 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.1845.00 -72.28 -7.11 0.00 -749.7 0.00 749.66 4,176.31 1,107.59 5,304.49 4,560.00 0.02 -0.05 0.182
10.00 -70.39 -7.04 0.00 -714.1 0.00 714.09 4,123.50 1,084.61 5,086.68 4,408.26 0.1 -0.09 0.17915.00 -68.51 -6.97 0.00 -678.9 0.00 678.87 4,069.26 1,061.63 4,873.43 4,257.44 0.22 -0.14 0.17620.00 -66.66 -6.90 0.00 -644.0 0.00 644.01 4,013.58 1,038.65 4,664.74 4,107.62 0.39 -0.19 0.17325.00 -64.83 -6.83 0.00 -609.5 0.00 609.50 3,956.47 1,015.67 4,460.63 3,958.90 0.61 -0.24 0.17030.00 -63.03 -6.76 0.00 -575.4 0.00 575.35 3,897.92 992.68 4,261.08 3,811.39 0.89 -0.28 0.16735.00 -61.26 -6.68 0.00 -541.6 0.00 541.55 3,837.94 969.70 4,066.09 3,665.19 1.21 -0.33 0.16440.00 -59.52 -6.60 0.00 -508.1 0.00 508.13 3,776.52 946.72 3,875.67 3,520.38 1.58 -0.38 0.16045.00 -57.80 -6.54 0.00 -475.1 0.00 475.12 3,713.67 923.74 3,689.82 3,377.07 2.01 -0.43 0.15646.91 -57.16 -6.50 0.00 -462.6 0.00 462.60 3,689.24 914.95 3,619.91 3,322.65 2.19 -0.45 0.15550.00 -55.56 -6.44 0.00 -442.5 0.00 442.54 3,649.39 900.76 3,508.54 3,235.36 2.49 -0.48 0.15253.08 -54.00 -6.39 0.00 -422.7 0.00 422.70 2,857.95 750.80 2,924.98 2,537.94 2.82 -0.52 0.18655.00 -53.42 -6.33 0.00 -410.4 0.00 410.43 2,840.65 743.45 2,867.97 2,497.68 3.03 -0.54 0.18360.00 -51.95 -6.26 0.00 -378.8 0.00 378.77 2,794.59 724.30 2,722.13 2,393.44 3.62 -0.59 0.17763.00 -50.77 -6.16 0.00 -360.0 0.00 359.98 2,766.27 712.81 2,636.46 2,331.31 4 -0.63 0.17365.00 -50.20 -6.10 0.00 -347.7 0.00 347.67 2,747.10 705.15 2,580.10 2,290.09 4.27 -0.65 0.17070.00 -48.79 -6.01 0.00 -317.2 0.00 317.18 2,698.18 686.00 2,441.88 2,187.75 4.98 -0.71 0.16375.00 -47.12 -5.86 0.00 -287.2 0.00 287.15 2,647.83 666.85 2,307.46 2,086.52 5.75 -0.76 0.15580.00 -45.76 -5.76 0.00 -257.9 0.00 257.87 2,596.04 647.70 2,176.84 1,986.48 6.58 -0.82 0.14885.00 -44.44 -5.66 0.00 -229.1 0.00 229.07 2,542.81 628.54 2,050.03 1,887.74 7.47 -0.87 0.13990.00 -43.14 -5.57 0.00 -200.8 0.00 200.78 2,488.15 609.39 1,927.03 1,790.40 8.41 -0.92 0.13093.54 -42.24 -5.51 0.00 -181.1 0.00 181.08 2,448.63 595.85 1,842.32 1,722.45 9.11 -0.96 0.12295.00 -41.71 -5.46 0.00 -173.0 0.00 173.01 2,432.06 590.24 1,807.83 1,694.56 9.41 -0.97 0.11998.45 -40.46 -5.40 0.00 -154.2 0.00 154.15 1,802.83 469.45 1,429.40 1,251.05 10.12 -1.01 0.146
100.00 -40.12 -5.34 0.00 -145.8 0.00 145.80 1,791.36 464.71 1,400.69 1,230.45 10.45 -1.02 0.141105.00 -33.86 -4.68 0.00 -119.1 0.00 119.11 1,753.33 449.39 1,309.86 1,164.33 11.55 -1.07 0.122110.00 -32.81 -4.57 0.00 -95.7 0.00 95.72 1,713.87 434.07 1,222.08 1,099.03 12.7 -1.12 0.106115.00 -31.78 -4.49 0.00 -72.9 0.00 72.89 1,672.98 418.74 1,137.35 1,034.64 13.89 -1.16 0.090116.00 -27.09 -3.92 0.00 -68.4 0.00 68.39 1,664.63 415.68 1,120.76 1,021.88 14.14 -1.16 0.083117.00 -24.15 -3.42 0.00 -64.5 0.00 64.48 1,656.22 412.62 1,104.30 1,009.16 14.38 -1.17 0.079120.00 -23.57 -3.33 0.00 -54.2 0.00 54.22 1,630.65 403.42 1,055.65 971.26 15.12 -1.19 0.070125.00 -22.62 -3.23 0.00 -37.6 0.00 37.57 1,586.89 388.10 977.01 908.99 16.39 -1.22 0.056128.00 -14.53 -2.06 0.00 -27.9 0.00 27.88 1,559.94 378.91 931.28 872.20 17.16 -1.23 0.041130.00 -14.21 -1.98 0.00 -23.8 0.00 23.76 1,541.69 372.78 901.40 847.93 17.67 -1.24 0.037135.00 -13.43 -1.90 0.00 -13.8 0.00 13.84 1,495.06 357.46 828.84 788.18 18.98 -1.25 0.027137.00 -10.71 -1.48 0.00 -10.0 0.00 10.04 1,476.01 351.33 800.67 764.66 19.5 -1.26 0.020137.50 -6.81 -1.05 0.00 -9.3 0.00 9.30 1,471.21 349.80 793.70 758.82 19.63 -1.26 0.017140.00 -6.47 -0.97 0.00 -6.7 0.00 6.67 1,447.00 342.14 759.33 729.83 20.29 -1.26 0.014145.00 -5.79 -0.90 0.00 -1.8 0.00 1.80 1,383.54 326.82 692.86 666.26 21.62 -1.26 0.007146.00 0.00 -0.77 0.00 -0.9 0.00 0.90 1,370.57 323.76 679.93 653.76 21.88 -1.26 0.001
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 8 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Load Case: 1.0D + 1.0W 60 mph Wind with No Ice 23 IterationsGust Response Factor: 1.10Dead load Factor: 1.00Wind Load Factor: 1.00
CALCULATED FORCES
SegElev
(ft)
PuFY (-)(kips)
VuFX (-)(kips)
TuMY
(ft-kips)
MuMZ
(ft-kips)
MuMX
(ft-kips)
ResultantMoment(ft-kips)
PhiPn
(kips)
PhiVn
(kips)
PhiTn
(ft-kips)
PhiMn
(ft-kips)
TotalDeflect
(in)Rotation
(deg) Ratio
0.00 -46.85 -6.20 0.00 -679.0 0.00 679.02 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.1555.00 -45.49 -6.13 0.00 -648.0 0.00 648.01 4,176.31 1,107.59 5,304.49 4,560.00 0.02 -0.04 0.153
10.00 -44.16 -6.07 0.00 -617.3 0.00 617.34 4,123.50 1,084.61 5,086.68 4,408.26 0.08 -0.08 0.15115.00 -42.84 -6.00 0.00 -587.0 0.00 587.00 4,069.26 1,061.63 4,873.43 4,257.44 0.19 -0.12 0.14820.00 -41.55 -5.94 0.00 -557.0 0.00 556.98 4,013.58 1,038.65 4,664.74 4,107.62 0.34 -0.16 0.14625.00 -40.28 -5.87 0.00 -527.3 0.00 527.29 3,956.47 1,015.67 4,460.63 3,958.90 0.53 -0.2 0.14330.00 -39.04 -5.81 0.00 -497.9 0.00 497.91 3,897.92 992.68 4,261.08 3,811.39 0.77 -0.25 0.14135.00 -37.81 -5.74 0.00 -468.9 0.00 468.87 3,837.94 969.70 4,066.09 3,665.19 1.05 -0.29 0.13840.00 -36.61 -5.67 0.00 -440.2 0.00 440.15 3,776.52 946.72 3,875.67 3,520.38 1.37 -0.33 0.13545.00 -35.43 -5.62 0.00 -411.8 0.00 411.79 3,713.67 923.74 3,689.82 3,377.07 1.74 -0.37 0.13246.91 -34.98 -5.59 0.00 -401.0 0.00 401.03 3,689.24 914.95 3,619.91 3,322.65 1.89 -0.39 0.13050.00 -33.81 -5.54 0.00 -383.8 0.00 383.79 3,649.39 900.76 3,508.54 3,235.36 2.16 -0.42 0.12853.08 -32.66 -5.49 0.00 -366.7 0.00 366.74 2,857.95 750.80 2,924.98 2,537.94 2.44 -0.45 0.15655.00 -32.27 -5.44 0.00 -356.2 0.00 356.20 2,840.65 743.45 2,867.97 2,497.68 2.62 -0.46 0.15460.00 -31.29 -5.38 0.00 -329.0 0.00 328.98 2,794.59 724.30 2,722.13 2,393.44 3.13 -0.51 0.14963.00 -30.51 -5.29 0.00 -312.8 0.00 312.83 2,766.27 712.81 2,636.46 2,331.31 3.46 -0.54 0.14565.00 -30.13 -5.24 0.00 -302.2 0.00 302.25 2,747.10 705.15 2,580.10 2,290.09 3.69 -0.56 0.14370.00 -29.18 -5.16 0.00 -276.0 0.00 276.05 2,698.18 686.00 2,441.88 2,187.75 4.31 -0.61 0.13775.00 -28.06 -5.03 0.00 -250.2 0.00 250.24 2,647.83 666.85 2,307.46 2,086.52 4.98 -0.66 0.13180.00 -27.16 -4.95 0.00 -225.1 0.00 225.08 2,596.04 647.70 2,176.84 1,986.48 5.7 -0.71 0.12485.00 -26.27 -4.87 0.00 -200.3 0.00 200.31 2,542.81 628.54 2,050.03 1,887.74 6.47 -0.76 0.11790.00 -25.39 -4.80 0.00 -175.9 0.00 175.94 2,488.15 609.39 1,927.03 1,790.40 7.29 -0.8 0.10993.54 -24.79 -4.76 0.00 -159.0 0.00 158.96 2,448.63 595.85 1,842.32 1,722.45 7.89 -0.83 0.10295.00 -24.41 -4.72 0.00 -152.0 0.00 151.99 2,432.06 590.24 1,807.83 1,694.56 8.15 -0.85 0.10098.45 -23.51 -4.67 0.00 -135.7 0.00 135.69 1,802.83 469.45 1,429.40 1,251.05 8.77 -0.88 0.122
100.00 -23.29 -4.62 0.00 -128.5 0.00 128.47 1,791.36 464.71 1,400.69 1,230.45 9.06 -0.89 0.118105.00 -19.43 -4.07 0.00 -105.4 0.00 105.35 1,753.33 449.39 1,309.86 1,164.33 10.01 -0.93 0.102110.00 -18.74 -3.98 0.00 -85.0 0.00 85.02 1,713.87 434.07 1,222.08 1,099.03 11.01 -0.97 0.088115.00 -18.07 -3.93 0.00 -65.1 0.00 65.09 1,672.98 418.74 1,137.35 1,034.64 12.05 -1.01 0.074116.00 -15.05 -3.49 0.00 -61.2 0.00 61.16 1,664.63 415.68 1,120.76 1,021.88 12.26 -1.01 0.069117.00 -13.66 -3.00 0.00 -57.7 0.00 57.67 1,656.22 412.62 1,104.30 1,009.16 12.48 -1.02 0.065120.00 -13.29 -2.93 0.00 -48.7 0.00 48.68 1,630.65 403.42 1,055.65 971.26 13.12 -1.04 0.058125.00 -12.67 -2.86 0.00 -34.0 0.00 34.02 1,586.89 388.10 977.01 908.99 14.22 -1.06 0.045128.00 -8.25 -1.81 0.00 -25.4 0.00 25.44 1,559.94 378.91 931.28 872.20 14.9 -1.07 0.034130.00 -8.05 -1.76 0.00 -21.8 0.00 21.82 1,541.69 372.78 901.40 847.93 15.35 -1.08 0.031135.00 -7.56 -1.70 0.00 -13.0 0.00 13.03 1,495.06 357.46 828.84 788.18 16.49 -1.09 0.022137.00 -6.26 -1.30 0.00 -9.6 0.00 9.64 1,476.01 351.33 800.67 764.66 16.95 -1.1 0.017137.50 -3.72 -0.98 0.00 -9.0 0.00 8.99 1,471.21 349.80 793.70 758.82 17.06 -1.1 0.014140.00 -3.51 -0.92 0.00 -6.5 0.00 6.54 1,447.00 342.14 759.33 729.83 17.64 -1.1 0.011145.00 -3.10 -0.87 0.00 -1.9 0.00 1.93 1,383.54 326.82 692.86 666.26 18.79 -1.11 0.005146.00 0.00 -0.81 0.00 -1.1 0.00 1.06 1,370.57 323.76 679.93 653.76 19.02 -1.11 0.002
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 9 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
EQUIVALENT LATERAL FORCES METHOD ANALYSIS (Based on ASCE7-16 Chapters 11, 12 and 15)
Spectral Response Acceleration for Short Period (SS): 0.185
Spectral Response Acceleration at 1.0 Second Period (S1): 0.055
Long-Period Transition Period (TL – Seconds): 6
Importance Factor (Ie): 1.000
Site Coefficient Fa: 1.600
Site Coefficient Fv: 2.400
Response Modification Coefficient (R): 1.500
Design Spectral Response Acceleration at Short Period (Sds): 0.197
Design Spectral Response Acceleration at 1.0 Second Period (Sd1): 0.088
Seismic Response Coefficient (Cs): 0.030
Upper Limit CS: 0.030
Lower Limit CS: 0.030
Period based on Rayleigh Method (sec): 2.710
Redundancy Factor (p): 1.000
Seismic Force Distribution Exponent (k): 2.000
Total Unfactored Dead Load: 46.850 k
Seismic Base Shear (E): 1.410 k
1.2D + 1.0Ev + 1.0Eh Seismic
Segment
Height AboveBase
(ft)Weight
(lb)Wz
(lb-ft) Cvx
HorizontalForce
(lb)
VerticalForce
(lb)
40 145.5 80 1,703 0.004 5 10039 142.5 411 8,347 0.019 27 50938 138.75 211 4,064 0.009 13 26237 137.25 43 804 0.002 3 5336 136 192 3,544 0.008 11 23835 132.5 489 8,593 0.020 27 60734 129 200 3,327 0.008 11 24833 126.5 363 5,808 0.013 19 45032 122.5 617 9,256 0.021 30 76531 118.5 377 5,297 0.012 17 46830 116.5 132 1,788 0.004 6 16329 115.5 132 1,765 0.004 6 16428 112.5 671 8,486 0.019 27 83127 107.5 685 7,920 0.018 25 85026 102.5 712 7,480 0.017 24 88225 99.2267 223 2,198 0.005 7 27724 96.7267 894 8,367 0.019 27 1,10823 94.2683 384 3,410 0.008 11 47622 91.7683 603 5,081 0.012 16 74821 87.5 869 6,653 0.015 21 1,07720 82.5 887 6,040 0.014 19 1,10019 77.5 906 5,442 0.012 17 1,12318 72.5 925 4,860 0.011 16 1,14617 67.5 943 4,297 0.010 14 1,16916 64 382 1,567 0.004 5 47415 61.5 580 2,193 0.005 7 71914 57.5 981 3,244 0.007 10 1,21613 54.04 382 1,115 0.002 4 47312 51.54 1,152 3,059 0.007 10 1,42711 48.4567 1,170 2,747 0.006 9 1,45010 45.9567 444 938 0.002 3 5519 42.5 1,176 2,125 0.005 7 1,4588 37.5 1,199 1,685 0.004 5 1,4867 32.5 1,221 1,289 0.003 4 1,513
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 10 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Segment
Height AboveBase
(ft)Weight
(lb)Wz
(lb-ft) Cvx
HorizontalForce
(lb)
VerticalForce
(lb)
6 27.5 1,243 940 0.002 3 1,5415 22.5 1,265 641 0.002 2 1,5684 17.5 1,288 394 0.001 1 1,5963 12.5 1,310 205 0.000 1 1,6242 7.5 1,332 75 0.000 0 1,6511 2.5 1,354 8 0.000 0 1,679Samsung B5/B13 RRH-BR04C 146 211 4,496 0.010 14 261Samsung B2/B66A RRH-BR049 146 253 5,397 0.012 17 314Raycap RC3DC-3315-PF-48 146 64 1,364 0.003 4 79Samsung MT6407-77A 146 245 5,218 0.012 17 303Antel LPA-80080/4CF ___ 146 48 1,023 0.002 3 59Antel LPA-80063/4CF 146 40 853 0.002 3 50Andrew SBNHH-1D65B 146 304 6,484 0.015 21 377Generic Flat Low Profile Platform 146 1,875 39,968 0.091 128 2,324Generic Round Platform with Handrails 137.5 2,500 47,266 0.108 151 3,099Generic Round Platform with Handrails 128 2,500 40,960 0.093 131 3,099Generic Round Platform with Handrails 116 2,500 33,640 0.077 108 3,099Generic Round Platform with Handrails 105 2,500 27,562 0.063 88 3,099Generic GPS 137 10 188 0.000 1 12Generic GPS 63 10 40 0.000 0 12Alcatel-Lucent RRH2x50-08 137 317 5,957 0.014 19 393Alcatel-Lucent 1900 MHz 4X45 RRH 137 180 3,378 0.008 11 223Alcatel-Lucent TD-RRH8x20-25 w/ Solar Shield 137 210 3,941 0.009 13 260RFS APXVTM14-ALU-I20 137 169 3,164 0.007 10 209Commscope NNVV-65B-R4 137 232 4,358 0.010 14 288Powerwave Allgon LGP21401 128 85 1,386 0.003 4 105Raycap DC6-48-60-18-8F 128 60 983 0.002 3 74Ericsson Radio 8843 - B2 + B66A 128 216 3,534 0.008 11 267Ericsson RRUS 4478 B14 128 180 2,944 0.007 9 223Ericsson RRUS 4449 B5, B12 128 213 3,490 0.008 11 264Allgon 7770.00 128 105 1,720 0.004 6 130Generic Mount Reinforcement 128 200 3,277 0.008 10 248Generic Mount Reinforcement 116 400 5,382 0.012 17 496CCI DMP65R-BU8D 128 287 4,704 0.011 15 356CCI OPA65R-BU8D 128 230 3,760 0.009 12 284Ericsson Radio 4449 B71 B85A 117 225 3,080 0.007 10 279Ericsson 4460 BAND 2/25 117 327 4,476 0.010 14 405Commscope VV-65A-R1 117 71 977 0.002 3 88Ericsson AIR 6419 B41 117 250 3,421 0.008 11 310RFS APXVAARR24_43-U-NA20 117 384 5,252 0.012 17 476Raycap RDIDC-9181-PF-48 105 22 241 0.000 1 27Fujitsu TA08025-B604 105 192 2,113 0.005 7 238Fujitsu TA08025-B605 105 225 2,481 0.006 8 279Commscope FFVV-65B-R2 105 212 2,342 0.005 7 263Generic Flat Stand-Off 75 188 1,055 0.002 3 232Generic Flat Stand-Off 63 188 744 0.002 2 232
46,855 439,379 1.000 1,406 58,075
0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL)
Segment
Height AboveBase
(ft)Weight
(lb)Wz
(lb-ft) Cvx
HorizontalForce
(lb)
VerticalForce
(lb)
40 145.5 80 1,703 0.004 5 6939 142.5 411 8,347 0.019 27 35438 138.75 211 4,064 0.009 13 18237 137.25 43 804 0.002 3 3736 136 192 3,544 0.008 11 16535 132.5 489 8,593 0.020 27 42134 129 200 3,327 0.008 11 17233 126.5 363 5,808 0.013 19 31232 122.5 617 9,256 0.021 30 53131 118.5 377 5,297 0.012 17 32530 116.5 132 1,788 0.004 6 113
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 11 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Segment
Height AboveBase
(ft)Weight
(lb)Wz
(lb-ft) Cvx
HorizontalForce
(lb)
VerticalForce
(lb)
29 115.5 132 1,765 0.004 6 11428 112.5 671 8,486 0.019 27 57727 107.5 685 7,920 0.018 25 59026 102.5 712 7,480 0.017 24 61325 99.2267 223 2,198 0.005 7 19224 96.7267 894 8,367 0.019 27 77023 94.2683 384 3,410 0.008 11 33022 91.7683 603 5,081 0.012 16 51921 87.5 869 6,653 0.015 21 74820 82.5 887 6,040 0.014 19 76419 77.5 906 5,442 0.012 17 78018 72.5 925 4,860 0.011 16 79617 67.5 943 4,297 0.010 14 81216 64 382 1,567 0.004 5 32915 61.5 580 2,193 0.005 7 49914 57.5 981 3,244 0.007 10 84413 54.04 382 1,115 0.002 4 32812 51.54 1,152 3,059 0.007 10 99111 48.4567 1,170 2,747 0.006 9 1,00710 45.9567 444 938 0.002 3 3829 42.5 1,176 2,125 0.005 7 1,0128 37.5 1,199 1,685 0.004 5 1,0317 32.5 1,221 1,289 0.003 4 1,0516 27.5 1,243 940 0.002 3 1,0705 22.5 1,265 641 0.002 2 1,0894 17.5 1,288 394 0.001 1 1,1083 12.5 1,310 205 0.000 1 1,1272 7.5 1,332 75 0.000 0 1,1461 2.5 1,354 8 0.000 0 1,166Samsung B5/B13 RRH-BR04C 146 211 4,496 0.010 14 181Samsung B2/B66A RRH-BR049 146 253 5,397 0.012 17 218Raycap RC3DC-3315-PF-48 146 64 1,364 0.003 4 55Samsung MT6407-77A 146 245 5,218 0.012 17 211Antel LPA-80080/4CF ___ 146 48 1,023 0.002 3 41Antel LPA-80063/4CF 146 40 853 0.002 3 34Andrew SBNHH-1D65B 146 304 6,484 0.015 21 262Generic Flat Low Profile Platform 146 1,875 39,968 0.091 128 1,614Generic Round Platform with Handrails 137.5 2,500 47,266 0.108 151 2,151Generic Round Platform with Handrails 128 2,500 40,960 0.093 131 2,151Generic Round Platform with Handrails 116 2,500 33,640 0.077 108 2,151Generic Round Platform with Handrails 105 2,500 27,562 0.063 88 2,151Generic GPS 137 10 188 0.000 1 9Generic GPS 63 10 40 0.000 0 9Alcatel-Lucent RRH2x50-08 137 317 5,957 0.014 19 273Alcatel-Lucent 1900 MHz 4X45 RRH 137 180 3,378 0.008 11 155Alcatel-Lucent TD-RRH8x20-25 w/ Solar Shield 137 210 3,941 0.009 13 181RFS APXVTM14-ALU-I20 137 169 3,164 0.007 10 145Commscope NNVV-65B-R4 137 232 4,358 0.010 14 200Powerwave Allgon LGP21401 128 85 1,386 0.003 4 73Raycap DC6-48-60-18-8F 128 60 983 0.002 3 52Ericsson Radio 8843 - B2 + B66A 128 216 3,534 0.008 11 186Ericsson RRUS 4478 B14 128 180 2,944 0.007 9 155Ericsson RRUS 4449 B5, B12 128 213 3,490 0.008 11 183Allgon 7770.00 128 105 1,720 0.004 6 90Generic Mount Reinforcement 128 200 3,277 0.008 10 172Generic Mount Reinforcement 116 400 5,382 0.012 17 344CCI DMP65R-BU8D 128 287 4,704 0.011 15 247CCI OPA65R-BU8D 128 230 3,760 0.009 12 197Ericsson Radio 4449 B71 B85A 117 225 3,080 0.007 10 194Ericsson 4460 BAND 2/25 117 327 4,476 0.010 14 281Commscope VV-65A-R1 117 71 977 0.002 3 61Ericsson AIR 6419 B41 117 250 3,421 0.008 11 215RFS APXVAARR24_43-U-NA20 117 384 5,252 0.012 17 330Raycap RDIDC-9181-PF-48 105 22 241 0.000 1 19Fujitsu TA08025-B604 105 192 2,113 0.005 7 165Fujitsu TA08025-B605 105 225 2,481 0.006 8 194Commscope FFVV-65B-R2 105 212 2,342 0.005 7 183Generic Flat Stand-Off 75 188 1,055 0.002 3 161Generic Flat Stand-Off 63 188 744 0.002 2 161
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 12 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Segment
Height AboveBase
(ft)Weight
(lb)Wz
(lb-ft) Cvx
HorizontalForce
(lb)
VerticalForce
(lb)
46,855 439,379 1.000 1,406 40,320
1.2D + 1.0Ev + 1.0Eh Seismic
CALCULATED FORCES
Seg Elev
(ft)
PuFY (-)(kips)
VuFX (-)(kips)
TuMY
(ft-kips)
MuMZ
(fr-kips)
MuMx
(ft-kips)
ResultantMoment(ft-kips)
PhiPn
(kips)
PhiVn
(kips)
PhiTn
(kips)
PhiMn
(kips)
TotalDeflect
(in)Rotation
(deg) Ratio
0.00 -56.40 -1.41 0.00 -177.40 0.00 177.40 4,227.69 1,130.57 5,527 4,712.55 0.00 0.00 0.055.00 -54.74 -1.42 0.00 -170.35 0.00 170.35 4,176.31 1,107.59 5,304 4,560.00 0.01 -0.01 0.05
10.00 -53.12 -1.43 0.00 -163.25 0.00 163.25 4,123.50 1,084.61 5,087 4,408.26 0.02 -0.02 0.0515.00 -51.52 -1.44 0.00 -156.11 0.00 156.11 4,069.26 1,061.63 4,873 4,257.44 0.05 -0.03 0.0520.00 -49.96 -1.44 0.00 -148.93 0.00 148.93 4,013.58 1,038.65 4,665 4,107.62 0.09 -0.04 0.0525.00 -48.41 -1.45 0.00 -141.71 0.00 141.71 3,956.47 1,015.67 4,461 3,958.90 0.14 -0.05 0.0530.00 -46.90 -1.45 0.00 -134.47 0.00 134.47 3,897.92 992.68 4,261 3,811.39 0.20 -0.07 0.0535.00 -45.42 -1.45 0.00 -127.21 0.00 127.21 3,837.94 969.70 4,066 3,665.19 0.28 -0.08 0.0540.00 -43.96 -1.45 0.00 -119.95 0.00 119.95 3,776.52 946.72 3,876 3,520.38 0.36 -0.09 0.0545.00 -43.41 -1.46 0.00 -112.68 0.00 112.68 3,713.67 923.74 3,690 3,377.07 0.46 -0.10 0.0546.91 -41.96 -1.45 0.00 -109.89 0.00 109.89 3,689.24 914.95 3,620 3,322.65 0.50 -0.10 0.0450.00 -40.53 -1.44 0.00 -105.42 0.00 105.42 3,649.39 900.76 3,509 3,235.36 0.57 -0.11 0.0453.08 -40.06 -1.44 0.00 -100.97 0.00 100.97 2,857.95 750.80 2,925 2,537.94 0.65 -0.12 0.0555.00 -38.84 -1.44 0.00 -98.21 0.00 98.21 2,840.65 743.45 2,868 2,497.68 0.70 -0.12 0.0560.00 -38.12 -1.43 0.00 -91.03 0.00 91.03 2,794.59 724.30 2,722 2,393.44 0.84 -0.14 0.0563.00 -37.40 -1.43 0.00 -86.73 0.00 86.73 2,766.27 712.81 2,636 2,331.31 0.93 -0.15 0.0565.00 -36.23 -1.42 0.00 -83.87 0.00 83.87 2,747.10 705.15 2,580 2,290.09 0.99 -0.15 0.0570.00 -35.09 -1.41 0.00 -76.78 0.00 76.78 2,698.18 686.00 2,442 2,187.75 1.16 -0.17 0.0575.00 -33.73 -1.39 0.00 -69.74 0.00 69.74 2,647.83 666.85 2,307 2,086.52 1.34 -0.18 0.0580.00 -32.63 -1.38 0.00 -62.78 0.00 62.78 2,596.04 647.70 2,177 1,986.48 1.53 -0.19 0.0485.00 -31.55 -1.36 0.00 -55.90 0.00 55.90 2,542.81 628.54 2,050 1,887.74 1.74 -0.21 0.0490.00 -30.80 -1.34 0.00 -49.11 0.00 49.11 2,488.15 609.39 1,927 1,790.40 1.97 -0.22 0.0493.54 -30.33 -1.34 0.00 -44.36 0.00 44.36 2,448.63 595.85 1,842 1,722.45 2.13 -0.23 0.0495.00 -29.22 -1.31 0.00 -42.40 0.00 42.40 2,432.06 590.24 1,808 1,694.56 2.20 -0.23 0.0498.45 -28.94 -1.30 0.00 -37.89 0.00 37.89 1,802.83 469.45 1,429 1,251.05 2.37 -0.24 0.05
100.00 -28.06 -1.28 0.00 -35.88 0.00 35.88 1,791.36 464.71 1,401 1,230.45 2.45 -0.24 0.05105.00 -23.31 -1.13 0.00 -29.49 0.00 29.49 1,753.33 449.39 1,310 1,164.33 2.71 -0.26 0.04110.00 -22.48 -1.10 0.00 -23.86 0.00 23.86 1,713.87 434.07 1,222 1,099.03 2.98 -0.27 0.04115.00 -22.31 -1.09 0.00 -18.36 0.00 18.36 1,672.98 418.74 1,137 1,034.64 3.27 -0.28 0.03116.00 -18.55 -0.95 0.00 -17.27 0.00 17.27 1,664.63 415.68 1,121 1,021.88 3.33 -0.28 0.03117.00 -16.53 -0.87 0.00 -16.32 0.00 16.32 1,656.22 412.62 1,104 1,009.16 3.39 -0.28 0.03120.00 -15.76 -0.83 0.00 -13.72 0.00 13.72 1,630.65 403.42 1,056 971.26 3.56 -0.29 0.02125.00 -15.31 -0.81 0.00 -9.55 0.00 9.55 1,586.89 388.10 977 908.99 3.87 -0.29 0.02128.00 -10.02 -0.56 0.00 -7.11 0.00 7.11 1,559.94 378.91 931 872.20 4.05 -0.30 0.02130.00 -9.41 -0.53 0.00 -5.98 0.00 5.98 1,541.69 372.78 901 847.93 4.18 -0.30 0.01135.00 -9.17 -0.52 0.00 -3.31 0.00 3.31 1,495.06 357.46 829 788.18 4.49 -0.30 0.01137.00 -7.74 -0.44 0.00 -2.27 0.00 2.27 1,476.01 351.33 801 764.66 4.61 -0.30 0.01137.50 -4.38 -0.26 0.00 -2.05 0.00 2.05 1,471.21 349.80 794 758.82 4.65 -0.30 0.01140.00 -3.87 -0.23 0.00 -1.39 0.00 1.39 1,447.00 342.14 759 729.83 4.80 -0.30 0.01145.00 -3.77 -0.23 0.00 -0.23 0.00 0.23 1,383.54 326.82 693 666.26 5.12 -0.30 0.00146.00 0.00 -0.21 0.00 0.00 0.00 0.00 1,370.57 323.76 680 653.76 5.18 -0.30 0.00
0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL)
CALCULATED FORCES
Seg Elev
(ft)
PuFY (-)(kips)
VuFX (-)(kips)
TuMY
(ft-kips)
MuMZ
(fr-kips)
MuMx
(ft-kips)
ResultantMoment(ft-kips)
PhiPn
(kips)
PhiVn
(kips)
PhiTn
(kips)
PhiMn
(kips)
TotalDeflect
(in)Rotation
(deg) Ratio
0.00 -39.15 -1.41 0.00 -173.88 0.00 173.88 4,227.69 1,130.57 5,527 4,712.55 0.00 0.00 0.055.00 -38.01 -1.42 0.00 -166.84 0.00 166.84 4,176.31 1,107.59 5,304 4,560.00 0.01 -0.01 0.05
10.00 -36.88 -1.42 0.00 -159.77 0.00 159.77 4,123.50 1,084.61 5,087 4,408.26 0.02 -0.02 0.0515.00 -35.77 -1.43 0.00 -152.66 0.00 152.66 4,069.26 1,061.63 4,873 4,257.44 0.05 -0.03 0.0520.00 -34.68 -1.43 0.00 -145.53 0.00 145.53 4,013.58 1,038.65 4,665 4,107.62 0.09 -0.04 0.0425.00 -33.61 -1.43 0.00 -138.39 0.00 138.39 3,956.47 1,015.67 4,461 3,958.90 0.14 -0.05 0.0430.00 -32.56 -1.43 0.00 -131.23 0.00 131.23 3,897.92 992.68 4,261 3,811.39 0.20 -0.06 0.04
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 13 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
Seg Elev
(ft)
PuFY (-)(kips)
VuFX (-)(kips)
TuMY
(ft-kips)
MuMZ
(fr-kips)
MuMx
(ft-kips)
ResultantMoment(ft-kips)
PhiPn
(kips)
PhiVn
(kips)
PhiTn
(kips)
PhiMn
(kips)
TotalDeflect
(in)Rotation
(deg) Ratio35.00 -31.53 -1.43 0.00 -124.06 0.00 124.06 3,837.94 969.70 4,066 3,665.19 0.27 -0.08 0.0440.00 -30.52 -1.43 0.00 -116.90 0.00 116.90 3,776.52 946.72 3,876 3,520.38 0.36 -0.09 0.0445.00 -30.14 -1.43 0.00 -109.74 0.00 109.74 3,713.67 923.74 3,690 3,377.07 0.45 -0.10 0.0446.91 -29.13 -1.42 0.00 -107.00 0.00 107.00 3,689.24 914.95 3,620 3,322.65 0.49 -0.10 0.0450.00 -28.14 -1.42 0.00 -102.61 0.00 102.61 3,649.39 900.76 3,509 3,235.36 0.56 -0.11 0.0453.08 -27.81 -1.41 0.00 -98.25 0.00 98.25 2,857.95 750.80 2,925 2,537.94 0.63 -0.12 0.0555.00 -26.96 -1.41 0.00 -95.53 0.00 95.53 2,840.65 743.45 2,868 2,497.68 0.68 -0.12 0.0560.00 -26.47 -1.40 0.00 -88.50 0.00 88.50 2,794.59 724.30 2,722 2,393.44 0.82 -0.14 0.0563.00 -25.97 -1.40 0.00 -84.29 0.00 84.29 2,766.27 712.81 2,636 2,331.31 0.90 -0.14 0.0565.00 -25.15 -1.39 0.00 -81.50 0.00 81.50 2,747.10 705.15 2,580 2,290.09 0.97 -0.15 0.0570.00 -24.36 -1.37 0.00 -74.57 0.00 74.57 2,698.18 686.00 2,442 2,187.75 1.13 -0.16 0.0475.00 -23.42 -1.36 0.00 -67.70 0.00 67.70 2,647.83 666.85 2,307 2,086.52 1.31 -0.18 0.0480.00 -22.65 -1.34 0.00 -60.92 0.00 60.92 2,596.04 647.70 2,177 1,986.48 1.50 -0.19 0.0485.00 -21.91 -1.32 0.00 -54.22 0.00 54.22 2,542.81 628.54 2,050 1,887.74 1.70 -0.20 0.0490.00 -21.39 -1.31 0.00 -47.62 0.00 47.62 2,488.15 609.39 1,927 1,790.40 1.92 -0.21 0.0493.54 -21.06 -1.30 0.00 -43.00 0.00 43.00 2,448.63 595.85 1,842 1,722.45 2.08 -0.22 0.0395.00 -20.29 -1.27 0.00 -41.11 0.00 41.11 2,432.06 590.24 1,808 1,694.56 2.15 -0.23 0.0398.45 -20.09 -1.26 0.00 -36.73 0.00 36.73 1,802.83 469.45 1,429 1,251.05 2.31 -0.23 0.04
100.00 -19.48 -1.24 0.00 -34.78 0.00 34.78 1,791.36 464.71 1,401 1,230.45 2.39 -0.24 0.04105.00 -16.18 -1.09 0.00 -28.58 0.00 28.58 1,753.33 449.39 1,310 1,164.33 2.64 -0.25 0.03110.00 -15.60 -1.06 0.00 -23.13 0.00 23.13 1,713.87 434.07 1,222 1,099.03 2.91 -0.26 0.03115.00 -15.49 -1.06 0.00 -17.80 0.00 17.80 1,672.98 418.74 1,137 1,034.64 3.19 -0.27 0.03116.00 -12.88 -0.92 0.00 -16.74 0.00 16.74 1,664.63 415.68 1,121 1,021.88 3.24 -0.27 0.02117.00 -11.47 -0.84 0.00 -15.83 0.00 15.83 1,656.22 412.62 1,104 1,009.16 3.30 -0.27 0.02120.00 -10.94 -0.81 0.00 -13.31 0.00 13.31 1,630.65 403.42 1,056 971.26 3.47 -0.28 0.02125.00 -10.63 -0.79 0.00 -9.27 0.00 9.27 1,586.89 388.10 977 908.99 3.77 -0.28 0.02128.00 -6.95 -0.55 0.00 -6.90 0.00 6.90 1,559.94 378.91 931 872.20 3.95 -0.29 0.01130.00 -6.53 -0.52 0.00 -5.81 0.00 5.81 1,541.69 372.78 901 847.93 4.07 -0.29 0.01135.00 -6.37 -0.51 0.00 -3.22 0.00 3.22 1,495.06 357.46 829 788.18 4.37 -0.29 0.01137.00 -5.37 -0.43 0.00 -2.21 0.00 2.21 1,476.01 351.33 801 764.66 4.50 -0.29 0.01137.50 -3.04 -0.25 0.00 -1.99 0.00 1.99 1,471.21 349.80 794 758.82 4.53 -0.29 0.01140.00 -2.68 -0.23 0.00 -1.35 0.00 1.35 1,447.00 342.14 759 729.83 4.68 -0.29 0.00145.00 -2.62 -0.22 0.00 -0.22 0.00 0.22 1,383.54 326.82 693 666.26 4.99 -0.29 0.00146.00 0.00 -0.21 0.00 0.00 0.00 0.00 1,370.57 323.76 680 653.76 5.05 -0.29 0.00
ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H
CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03
©2007 - 2020 by ATC LLC. All rights reserved. Page 14 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17
ANALYSIS SUMMARY
Reactions . . Max Usage .
Load Case
ShearFX
(kips)
ShearFZ
(kips)
AxialFY
(kips)
MomentMX
(ft-kips)
MomentMY
(ft-kips)
MomentMZ
(ft-kips)Elev
(ft)Interaction
Ratio
1.2D + 1.0W 27.74 0.00 56.18 0.00 0.00 3064.77 53.08 0.670.9D + 1.0W 27.72 0.00 42.13 0.00 0.00 3016.64 53.08 0.651.2D + 1.0Di + 1.0Wi 7.19 0.00 74.18 0.00 0.00 785.58 53.08 0.191.2D + 1.0Ev + 1.0Eh 1.46 0.00 56.40 0.00 0.00 177.40 53.08 0.050.9D - 1.0Ev + 1.0Eh 1.43 0.00 39.15 0.00 0.00 173.88 53.08 0.051.0D + 1.0W 6.20 0.00 46.85 0.00 0.00 679.02 53.08 0.16
ASSET: CODE: ANSI/TIA-222-H
CUSTOMER: ENG NO: 14071468_C3_03
Task ID: 167152 Page 1 of 2 5/3/2022 15:08:23
BASE PLATE ANALYSIS @ 0 FT
PLATE PARAMETERS (ID# 3478)
Diameter: 69 in
Shape: Round
Thickness: 1.75 in
Grade: A572-60
Yield Strength: 60 ksi
Tensile Strength: 75 ksi
Rod Detail Type: d
Clear Distance 3.375 in
Base Weld Size: 0.125 in
Orientation Offset: - °
Analysis Type: Plastic
Neutral Axis: 270 °
ANCHOR ROD PARAMETERS
Class Arrangement Quantity Diameter(in)
Circle(in) Grade Fy
(ksi)Fu
(ksi)Spacing
(in)Offset
(°)
Original[ID# 8063]
Radial 16 2.25 63 A615-75 75 100 - -
ANCHOR ROD GEOMETRY AND APPLIED LOADS --- ORIGINAL (16) 2.25"ø [ID 8063]
Position Radians X(in)
Y(in)
Moment Arm(in)
Inertia(in4)
Axial Load(k)
Shear Load(k)
1 0.393 29.10 12.06 27.890 2526.992 128.19 1.06
2 0.785 22.27 22.27 21.346 1480.625 128.19 1.95
3 1.178 12.06 29.10 11.552 434.259 128.19 2.55
4 1.571 0.00 31.50 0.000 0.839 128.19 2.76
5 1.963 -12.06 29.10 -11.552 434.258 -114.14 2.55
6 2.356 -22.27 22.27 -21.346 1480.624 -114.14 1.95
7 2.749 -29.10 12.06 -27.890 2526.992 -114.14 1.06
8 3.142 -31.50 0.00 -30.188 2960.411 -114.14 0.00
9 3.534 -29.10 -12.06 -27.890 2526.991 -114.14 1.06
10 3.927 -22.27 -22.27 -21.346 1480.624 -114.14 1.95
11 4.320 -12.06 -29.10 -11.552 434.258 -114.14 2.55
12 4.712 0.00 -31.50 0.000 0.839 128.19 2.76
13 5.105 12.06 -29.10 11.552 434.258 128.19 2.55
14 5.498 22.27 -22.27 21.346 1480.625 128.19 1.95
15 5.890 29.10 -12.06 27.890 2526.991 128.19 1.06
16 6.283 31.50 0.00 30.188 2960.411 128.19 0.00
REACTION DISTRIBUTION
Component ID MomentMu (k-ft)
Axial LoadPu (k)
ShearVu (k) Moment Factor
Pole 54.5"ø x 0.375" (18 Sides) 3064.8 56.18 27.74 1.000
Bolt Group Original (16) 2.25"ø 3064.8 - 27.74 1.000
TOTALS 3064.77 56.18 27.74
411216, CT Chaplin South CT
T-MOBILE
ASSET: CODE: ANSI/TIA-222-H
CUSTOMER: ENG NO: 14071468_C3_03
Task ID: 167152 Page 2 of 2 5/3/2022 15:08:23
COMPONENT PROPERTIES
Component IDGross Area
(in2)Net Area
(in2)Individual Inertia
(in4)Moment of Inertia
(in4)Threads/in
Pole 54.5"ø x 0.375" (18 Sides) 63.4413 - - 23234.51 -
Bolt Group Original (16) 2.25"ø 3.9761 3.2477 0.8393 23690.00 4.5
EXTERNAL BASE PLATE BEND LINE ANALYSIS @ 0 FT
POLE PROPERTIES PLATE PROPERTIES
Flat-to-Flat Diameter: 54.62 in Neutral Axis: 270 °
Point-to-Point Diameter: 55.47 in Bend Line Lower Limit: 5.655 rad
Flat Width: 9.632 in Bend Line Upper Limit: 0.628 rad
Flat Radians: 0.349 rad
Bend LineChord Length
(in)Additional Length
(in)Section Modulus
(in3)Applied Moment
Mu (k-in)Moment Capacity
φMn (k-in)Ratio
Flat 37.733 0.00 28.889 614.0 1560.0 0.394
Corner 36.482 0.00 27.932 427.0 1508.3 0.283
Circumferential 51.481 0.00 39.415 1089.3 2128.4 0.512
PLASTIC ANCHOR ROD ANALYSIS
Class Group Quantity Rod Diameter(in)
Applied Axial LoadPu (k)
Applied Shear LoadVu (k)
Compressive CapacityφPn (k)
Ratio
Original 16 2.25 128.1 2.8 243.6 0.549
411216, CT Chaplin South CT
T-MOBILE
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 1/15
Section 1 - Site Information
Section 2 - Existing Template Images
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
Site ID: CT11508FStatus: FinalVersion: 3Project Type: AnchorApproved: 3/1/2022 4:27:24 PMApproved By: [email protected] Modified: 3/1/2022 4:27:24 PMLast Modified By: [email protected]
Site Name: CT508//Verizon ChaplinSite Class: MonopoleSite Type: Structure Non BuildingPlan Year: 2022Market: CONNECTICUT CTVendor: EricssonLandlord: Verizon Wireless
Latitude: 41.78461418Longitude: -72.13554480Address: 121 Palmer RoadCity, State: Chaplin, CTRegion: NORTHEAST
RAN Template: 67D5D998E ODE+6160 AL Template: 67D5998E_1xAIR+1OP+1QP
Sector Count: 3 Antenna Count: 9 Coax Line Count: 0 TMA Count: 0 RRU Count: 6
----- This section is intentionally blank. -----
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 2/15
Section 3 - Proposed Template Images
67D5998E_1xAIR+1OP+1QP.JPG
Notes:
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 3/15
Section 4 - Siteplan Images
----- This section is intentionally blank. -----
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 4/15
Section 5 - RAN Equipment
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
Existing RAN EquipmentTemplate: 67D94E
Enclosure 1
Enclosure Type RBS 6201 ODE
Baseband DUG20 BB 6630 BB 6630G1900 L2100
L1900L700L600
N600
Hybrid CableSystem Ericsson 6x12 HCS *Select Length & AWG*
Radio RUS02 B2 (x 3 ) RUS02 B2 (x 3 )G1900 L1900
Proposed RAN EquipmentTemplate: 67D5D998E ODE+6160
Enclosure 1 2 3 4
Enclosure Type RBS 6201 ODE Ancillary Equipment (Ericsson) Enclosure 6160 AC V1 B160
Baseband BB 6630 DUG20 BB 6630 RP 6651 RP 6651L2100
L1900
G1900 L700
L600N600
N2500 L2500
Hybrid CableSystem Ericsson 6x12 HCS *Select Length
& AWG*
Ericsson Hybrid Trunk 6/24 4AWG50m
PSU 4813 vR4A (Kit)
Ericsson Hybrid Trunk 6/24 4AWG50m
Transport System CSR IXRe V2 (Gen2)
Remove and return all cabinet radios from existing base station cabinet.
Upgrade 6201 breaker to 125A.
Add (1) Enclosure 6160.
Add (1) iXRe Router to new Enclosure 6160.
Add (1) RP 6651 for N2500 to new Enclosure 6160.
Add (1) RP 6651 for L2500 to new Enclosure 6160.
Add (1) PSU4813 Voltage Booster to new Enclosure 6160.
Add (1) Battery Cabinet B160.
Existing : (1) 6x12,
Remove all Coax,
Add (1) 6X24 HCS terminating at the Enclosure 6160. And (1) 6x24 terminating at 6201. Connect DC for the AIR6419 B41 to the PSU4813 Voltage Booster.
RAN Scope of Work:
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 5/15
Section 6 - A&L Equipment
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
Existing Template: 67D94E_1DP+1OPProposed Template: 67D5998E_1xAIR+1OP+1QP
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 6/15
Sector 1 (Existing) view from behindCoverage Type A - Outdoor Macro
Antenna 1 2 3 4
Antenna Model RFS - APXV18-206517S-C-A20 (Dual)
Empty Antenna Mount (Emptymount)
Empty Antenna Mount (Emptymount)
RFS - APXVAARR24_43-U-NA20 (Octo)
Azimuth 60 60
M. Tilt 0 0
Height 118 118
Ports P1 P2 P3 P4 P5
Active Tech. L1900 G1900 L700
L600
N600
L700
L600
N600
L2100
Dark Tech.
Restricted Tech.
Decomm. Tech.
E. Tilt 2 2 2 2 2
Cables 1-5/8" Coax - 145 ft. (x2) CoaxJumper(x2)
CoaxJumper(x2)
1-5/8"Coax- 145ft.(x2)
TMAs Generic Twin Style 1A - PCS(AtAntenna)
EricssonTwinStyle1BX-KRY112144/2(AtAntenna)
Diplexers /Combiners
Radio Radio4449B71+B85 (AtAntenna)
Radio4415B66A (AtCabinet)
SHARED
Radio4449B71+B85 (AtAntenna)
Sector Equipment
Unconnected Equipment:
Replace LB Dual in Position 4 with (1) LB/MB Octo. Add (1) Radio 4449 B71+B12 to Position 4 for L600 and L700.
Add (1) AWS TMA to Position 4. Connect Coaxial Lines and AWS TMA in Position 4 to Mid-Band Ports of LB/MB Octo. Ensure to cascade all 3 octo rets to 4449 for L21 control
Scope of Work:
*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 7/15
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 8/15
Sector 1 (Proposed) view from behindCoverage Type A - Outdoor Macro
Antenna 1 2 3 4
Antenna Model AIR 6419 B41 (Active Antenna -Massive MIMO)
Commscope_VV-65A-R1 (Quad) Empty Antenna Mount (Emptymount)
RFS - APXVAARR24_43-U-NA20 (Octo)
Azimuth 60 60 60
M. Tilt 0 0 0
Height 118 118 118
Ports P1 P2 P3 P4 P5 P6 P7 P8
Active Tech. L2500 N2500 L2500 N2500 L2100 L1900
G1900
L2100 L1900
G1900
L700
L600
N600
L700
L600
N600
Dark Tech.
Restricted Tech.
Decomm. Tech.
E. Tilt 2 2 2 2
Cables Fiber Jumper(x2)
Fiber Jumper(x2)
Coax Jumper(x2)
Fiber Jumper
Coax Jumper(x2)
Fiber Jumper
CoaxJumper(x2)
FiberJumper
CoaxJumper(x2)
FiberJumper
TMAs
Diplexers /Combiners
Radio Radio 4460B25+B66 (AtAntenna)
Radio4449B71+B85 (AtAntenna)
SHARED Radio 4460
B25+B66 (AtAntenna)
SHARED
Radio4449B71+B85 (AtAntenna)
Sector Equipment
Unconnected Equipment:
There will be Three antennae per sector.
Remove all TMAs.
Remove all diplexers.
Remove all Coaxial Lines.
Replace Antenna APXV18 from Position 1 with (1) AIR6419 B41 for L2500 and N2500.
Install (1) mid-band Quad VV-65A-R1 in Position 2 .
Add (1) Radio 4460 B25+B66 for L2100, L1900 (Both carriers), and GSM to Position 2 at antenna.
Remove Radio 4415 B66A from position 4 at antenna.
Ensure RET control is enabled for all technology layers according to the Design Documents
Scope of Work:
*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 9/15
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
Sector 2 (Existing) view from behindCoverage Type A - Outdoor Macro
Antenna 1 2 3 4
Antenna Model RFS - APXV18-206517S-C-A20 (Dual)
Empty Antenna Mount (Emptymount)
Empty Antenna Mount (Emptymount)
RFS - APXVAARR24_43-U-NA20 (Octo)
Azimuth 180 180
M. Tilt 0 0
Height 118 118
Ports P1 P2 P3 P4 P5
Active Tech. L1900 G1900 L700
L600
N600
L700
L600
N600
L2100
Dark Tech.
Restricted Tech.
Decomm. Tech.
E. Tilt 2 2 2 2 2
Cables 1-5/8" Coax - 145 ft. (x2) CoaxJumper(x2)
CoaxJumper(x2)
1-5/8"Coax- 145ft.(x2)
TMAs Generic Twin Style 1A - PCS(AtAntenna)
EricssonTwinStyle1BX-KRY112144/2(AtAntenna)
Diplexers /Combiners
Radio Radio4449B71+B85 (AtAntenna)
Radio4415B66A (AtCabinet)
SHARED
Radio4449B71+B85 (AtAntenna)
Sector Equipment
Unconnected Equipment:
Replace LB Dual in Position 4 with (1) LB/MB Octo. Add (1) Radio 4449 B71+B12 to Position 4 for L600 and L700.
Add (1) AWS TMA to Position 4. Connect Coaxial Lines and AWS TMA in Position 4 to Mid-Band Ports of LB/MB Octo. Ensure to cascade all 3 octo rets to 4449 for L21 control
Scope of Work:
*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 10/15
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32… 11/15
Sector 2 (Proposed) view from behindCoverage Type A - Outdoor Macro
Antenna 1 2 3 4
Antenna Model AIR 6419 B41 (Active Antenna -Massive MIMO)
Commscope_VV-65A-R1 (Quad) Empty Antenna Mount (Emptymount)
RFS - APXVAARR24_43-U-NA20 (Octo)
Azimuth 180 180 180
M. Tilt 0 0 0
Height 118 118 118
Ports P1 P2 P3 P4 P5 P6 P7 P8
Active Tech. L2500 N2500 L2500 N2500 L2100 L1900
G1900
L2100 L1900
G1900
L700
L600
N600
L700
L600
N600
Dark Tech.
Restricted Tech.
Decomm. Tech.
E. Tilt 2 2 2 2
Cables Fiber Jumper(x2)
Fiber Jumper(x2)
Coax Jumper(x2)
Fiber Jumper
Coax Jumper(x2)
Fiber Jumper
CoaxJumper(x2)
FiberJumper
CoaxJumper(x2)
FiberJumper
TMAs
Diplexers /Combiners
Radio Radio 4460B25+B66 (AtAntenna)
Radio4449B71+B85 (AtAntenna)
SHARED Radio 4460
B25+B66 (AtAntenna)
SHARED
Radio4449B71+B85 (AtAntenna)
Sector Equipment
Unconnected Equipment:
There will be Three antennae per sector.
Remove all TMAs.
Remove all diplexers.
Remove all Coaxial Lines.
Replace Antenna APXV18 from Position 1 with (1) AIR6419 B41 for L2500 and N2500.
Install (1) mid-band Quad VV-65A-R1 in Position 2 .
Add (1) Radio 4460 B25+B66 for L2100, L1900 (Both carriers), and GSM to Position 2 at antenna.
Remove Radio 4415 B66A from position 4 at antenna.
Ensure RET control is enabled for all technology layers according to the Design Documents
Scope of Work:
*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 12/15
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
Sector 3 (Existing) view from behindCoverage Type A - Outdoor Macro
Antenna 1 2 3 4
Antenna Model RFS - APXV18-206517S-C-A20 (Dual)
Empty Antenna Mount (Emptymount)
Empty Antenna Mount (Emptymount)
RFS - APXVAARR24_43-U-NA20 (Octo)
Azimuth 300 300
M. Tilt 0 0
Height 118 118
Ports P1 P2 P3 P4 P5
Active Tech. L1900 G1900 L700
L600
N600
L700
L600
N600
L2100
Dark Tech.
Restricted Tech.
Decomm. Tech.
E. Tilt 2 2 2 2 2
Cables 1-5/8" Coax - 145 ft. (x2) CoaxJumper(x2)
CoaxJumper(x2)
1-5/8"Coax- 145ft.(x2)
TMAs Generic Twin Style 1A - PCS(AtAntenna)
EricssonTwinStyle1BX-KRY112144/2(AtAntenna)
Diplexers /Combiners
Radio Radio4449B71+B85 (AtAntenna)
Radio4415B66A (AtCabinet)
SHARED
Radio4449B71+B85 (AtAntenna)
Sector Equipment
Unconnected Equipment:
Replace LB Dual in Position 4 with (1) LB/MB Octo. Add (1) Radio 4449 B71+B12 to Position 4 for L600 and L700.
Add (1) AWS TMA to Position 4. Connect Coaxial Lines and AWS TMA in Position 4 to Mid-Band Ports of LB/MB Octo. Ensure to cascade all 3 octo rets to 4449 for L21 control
Scope of Work:
*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 13/15
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 14/15
Sector 3 (Proposed) view from behindCoverage Type A - Outdoor Macro
Antenna 1 2 3 4
Antenna Model AIR 6419 B41 (Active Antenna -Massive MIMO)
Commscope_VV-65A-R1 (Quad) Empty Antenna Mount (Emptymount)
RFS - APXVAARR24_43-U-NA20 (Octo)
Azimuth 300 300 300
M. Tilt 0 0 0
Height 118 118 118
Ports P1 P2 P3 P4 P5 P6 P7 P8
Active Tech. L2500 N2500 L2500 N2500 L2100 L1900
G1900
L2100 L1900
G1900
L700
L600
N600
L700
L600
N600
Dark Tech.
Restricted Tech.
Decomm. Tech.
E. Tilt 2 2 2 2
Cables Fiber Jumper(x2)
Fiber Jumper(x2)
Coax Jumper(x2)
Fiber Jumper
Coax Jumper(x2)
Fiber Jumper
CoaxJumper(x2)
FiberJumper
CoaxJumper(x2)
FiberJumper
TMAs
Diplexers /Combiners
Radio Radio 4460B25+B66 (AtAntenna)
Radio4449B71+B85 (AtAntenna)
SHARED Radio 4460
B25+B66 (AtAntenna)
SHARED
Radio4449B71+B85 (AtAntenna)
Sector Equipment
Unconnected Equipment:
There will be Three antennae per sector.
Remove all TMAs.
Remove all diplexers.
Remove all Coaxial Lines.
Replace Antenna APXV18 from Position 1 with (1) AIR6419 B41 for L2500 and N2500.
Install (1) mid-band Quad VV-65A-R1 in Position 2 .
Add (1) Radio 4460 B25+B66 for L2100, L1900 (Both carriers), and GSM to Position 2 at antenna.
Remove Radio 4415 B66A from position 4 at antenna.
Ensure RET control is enabled for all technology layers according to the Design Documents
Scope of Work:
*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.
3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02
https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 15/15
Section 7 - Power Systems Equipment
RAN Template:67D5D998E ODE+6160
A&L Template:67D5998E_1xAIR+1OP+1QP
CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)
PORs: Anchor_Phase 3
Existing Power Systems Equipment----- This section is intentionally blank. -----
Proposed Power Systems EquipmentEnclosure 1
Enclosure Type Enclosure 6160 AC V1
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
RADIO FREQUENCY EMISSIONS ANALYSIS REPORT
EVALUATION OF HUMAN EXPOSURE POTENTIAL
TO NON-IONIZING EMISSIONS
T-Mobile Existing Facility
Site ID: CT11508F
CT508//Verizon Chaplin
123 Palmer Road
Chaplin, Connecticut 06235
May 25, 2022
EBI Project Number: 6222003373
Site Compliance Summary
Compliance Status: COMPLIANT
Site total MPE% of FCC general population
allowable limit:
29.14%
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
May 25, 2022
T-Mobile Attn: Jason Overbey, RF Manager 35 Griffin Road South Bloomfield, Connecticut 06002
Emissions Analysis for Site: CT11508F - CT508//Verizon Chaplin
EBI Consulting was directed to analyze the proposed T-Mobile facility located at 123 Palmer Road in Chaplin, Connecticut for the purpose of determining whether the emissions from the Proposed T-Mobile Antenna Installation located on this property are within specified federal limits.
All information used in this report was analyzed as a percentage of current Maximum Permissible Exposure (% MPE) as listed in the FCC OET Bulletin 65 Edition 97-01and ANSI/IEEE Std C95.1. The FCC regulates Maximum Permissible Exposure in units of microwatts per square centimeter (µW/cm2). The number of µW/cm2 calculated at each sample point is called the power density. The exposure limit for power density varies depending upon the frequencies being utilized. Wireless Carriers and Paging Services use different frequency bands each with different exposure limits; therefore, it is necessary to report results and limits in terms of percent MPE rather than power density.
All results were compared to the FCC (Federal Communications Commission) radio frequency exposure rules, 47 CFR 1.1307(b)(1) – (b)(3), to determine compliance with the Maximum Permissible Exposure (MPE) limits for General Population/Uncontrolled environments as defined below.
General population/uncontrolled exposure limits apply to situations in which the general population may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Therefore, members of the general population would always be considered under this category when exposure is not employment related, for example, in the case of a telecommunications tower that exposes persons in a nearby residential area.
Public exposure to radio frequencies is regulated and enforced in units of microwatts per square centimeter (μW/cm2). The general population exposure limits for the 600 MHz and 700 MHz frequency bands are approximately 400 μW/cm2 and 467 μW/cm2, respectively. The general population exposure limit for the 1900 MHz (PCS), 2100 MHz (AWS) and 11 GHz frequency bands is 1000 μW/cm2. Because each carrier will be using different frequency bands, and each frequency band has different exposure limits, it is necessary to report percent of MPE rather than power density.
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
Occupational/controlled exposure limits apply to situations in which persons are exposed as a consequence of their employment and in which those persons who are exposed have been made fully aware of the potential for exposure and can exercise control over their exposure. Occupational/controlled exposure limits also apply where exposure is of a transient nature as a result of incidental passage through a location where exposure levels may be above general population/uncontrolled limits (see below), as long as the exposed person has been made fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means.
Additional details can be found in FCC OET 65.
CALCULATIONS
Calculations were done for the proposed T-Mobile Wireless antenna facility located at 123 Palmer Road in Chaplin, Connecticut using the equipment information listed below. All calculations were performed per the specifications under FCC OET 65. Since T-Mobile is proposing highly focused directional panel antennas, which project most of the emitted energy out toward the horizon, all calculations were performed assuming a lobe representing the maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was focused at the base of the tower. For this report, the sample point is the top of a 6-foot person standing at the base of the tower.
For all calculations, all equipment was calculated using the following assumptions:
1) 2 LTE channels (600 MHz Band) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel.
2) 1 NR channel (600 MHz Band) was considered for each sector of the proposed installation. This Channel has a transmit power of 80 Watts.
3) 2 LTE channels (700 MHz Band) were considered for each sector of the proposed installation.
These Channels have a transmit power of 30 Watts per Channel.
4) 4 GSM channels (PCS Band - 1900 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel.
5) 2 LTE channels (PCS Band - 1900 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 60 Watts per Channel.
6) 2 LTE channels (AWS Band – 2100 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 60 Watts per Channel.
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
7) 1 LTE Traffic channel (LTE 1C and 2C BRS Band - 2500 MHz) was considered for each sector of the proposed installation. This Channel has a transmit power of 60 Watts.
8) 1 LTE Broadcast channel (LTE 1C and 2C BRS Band - 2500 MHz) was considered for each
sector of the proposed installation. This Channel has a transmit power of 20 Watts. 9) 1 NR Traffic channel (BRS Band - 2500 MHz) was considered for each sector of the proposed
installation. This Channel has a transmit power of 120 Watts. 10) 1 NR Broadcast channel (BRS Band - 2500 MHz) was considered for each sector of the
proposed installation. This Channel has a transmit power of 40 Watts.
11) All radios at the proposed installation were considered to be running at full power and were uncombined in their RF transmissions paths per carrier prescribed configuration. Per FCC OET Bulletin No. 65 - Edition 97-01 recommendations to achieve the maximum anticipated value at each sample point, all power levels emitting from the proposed antenna installation are increased by a factor of 2.56 to account for possible in-phase reflections from the surrounding environment. This is rarely the case, and if so, is never continuous.
12) For the following calculations, the sample point was the top of a 6-foot person standing at the base of the tower. The maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was used in this direction. This value is a very conservative estimate as gain reductions for these particular antennas are typically much higher in this direction.
13) The antennas used in this modeling are the Ericsson AIR 6419 for the 2500 MHz / 2500 MHz
/ 2500 MHz / 2500 MHz channel(s), the Commscope VV-65A-R1 for the 1900 MHz / 1900 MHz / 2100 MHz channel(s), the RFS APXVAARR24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz channel(s) in Sector A, the Ericsson AIR 6419 for the 2500 MHz / 2500 MHz / 2500 MHz / 2500 MHz channel(s), the Commscope VV-65A-R1 for the 1900 MHz / 1900 MHz / 2100 MHz channel(s), the RFS APXVAARR24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz channel(s) in Sector B, the Ericsson AIR 6419 for the 2500 MHz / 2500 MHz / 2500 MHz / 2500 MHz channel(s), the Commscope VV-65A-R1 for the 1900 MHz / 1900 MHz / 2100 MHz channel(s), the RFS APXVAARR24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz channel(s) in Sector C. This is based on feedback from the carrier with regard to anticipated antenna selection. All Antenna gain values and associated transmit power levels are shown in the Site Inventory and Power Data table below. The maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was used for all
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
calculations. This value is a very conservative estimate as gain reductions for these particular antennas are typically much higher in this direction.
14) The antenna mounting height centerline of the proposed antennas is 117 feet above ground level (AGL).
15) Emissions values for additional carriers were taken from the Connecticut Siting Council active database. Values in this database are provided by the individual carriers themselves.
16) All calculations were done with respect to uncontrolled / general population threshold limits.
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
T-Mobile Site Inventory and Power Data
Sector: A Sector: B Sector: C Antenna #: 1 Antenna #: 1 Antenna #: 1
Make / Model: Ericsson AIR 6419 Make / Model: Ericsson AIR 6419 Make / Model: Ericsson AIR 6419
Frequency Bands: 2500 MHz / 2500 MHz / 2500 MHz /
2500 MHz Frequency Bands:
2500 MHz / 2500 MHz / 2500 MHz /
2500 MHz Frequency Bands:
2500 MHz / 2500 MHz / 2500 MHz /
2500 MHz
Gain: 22.05 dBd / 15.55 dBd / 22.05 dBd /
15.55 dBd Gain:
22.05 dBd / 15.55 dBd / 22.05 dBd /
15.55 dBd Gain:
22.05 dBd / 15.55 dBd / 22.05 dBd /
15.55 dBd Height (AGL): 117 feet Height (AGL): 117 feet Height (AGL): 117 feet
Channel Count: 4 Channel Count: 4 Channel Count: 4 Total TX Power (W): 240.00 Watts Total TX Power (W): 240.00 Watts Total TX Power (W): 240.00 Watts
ERP (W): 31,011.95 ERP (W): 31,011.95 ERP (W): 31,011.95 Antenna A1 MPE %: 9.05% Antenna B1 MPE %: 9.05% Antenna C1 MPE %: 9.05%
Antenna #: 2 Antenna #: 2 Antenna #: 2
Make / Model: Commscope VV-65A-R1 Make / Model: Commscope VV-65A-
R1 Make / Model: Commscope VV-65A-R1
Frequency Bands: 1900 MHz / 1900 MHz / 2100 MHz
Frequency Bands: 1900 MHz / 1900 MHz / 2100 MHz
Frequency Bands: 1900 MHz / 1900 MHz / 2100 MHz
Gain: 15.55 dBd / 15.55 dBd / 16.05 dBd Gain: 15.55 dBd / 15.55
dBd / 16.05 dBd Gain: 15.55 dBd / 15.55 dBd / 16.05 dBd
Height (AGL): 117 feet Height (AGL): 117 feet Height (AGL): 117 feet Channel Count: 8 Channel Count: 8 Channel Count: 8
Total TX Power (W): 360.00 Watts Total TX Power (W): 360.00 Watts Total TX Power (W): 360.00 Watts ERP (W): 13,446.73 ERP (W): 13,446.73 ERP (W): 13,446.73
Antenna A2 MPE %: 3.92% Antenna B2 MPE %: 3.92% Antenna C2 MPE %: 3.92% Antenna #: 3 Antenna #: 3 Antenna #: 3
Make / Model: RFS
APXVAARR24_43-U-NA20
Make / Model: RFS
APXVAARR24_43-U-NA20
Make / Model: RFS
APXVAARR24_43-U-NA20
Frequency Bands: 600 MHz / 600 MHz /
700 MHz Frequency Bands:
600 MHz / 600 MHz / 700 MHz
Frequency Bands: 600 MHz / 600 MHz /
700 MHz
Gain: 12.95 dBd / 12.95 dBd / 13.35 dBd Gain: 12.95 dBd / 12.95 dBd
/ 13.35 dBd Gain: 12.95 dBd / 12.95 dBd / 13.35 dBd
Height (AGL): 117 feet Height (AGL): 117 feet Height (AGL): 117 feet Channel Count: 5 Channel Count: 5 Channel Count: 5
Total TX Power (W): 200.00 Watts Total TX Power (W): 200.00 Watts Total TX Power (W): 200.00 Watts ERP (W): 4,059.02 ERP (W): 4,059.02 ERP (W): 4,059.02
Antenna A3 MPE %: 2.83% Antenna B3 MPE %: 2.83% Antenna C3 MPE %: 2.83%
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
Site Composite MPE % Carrier MPE %
T-Mobile (Max at Sector A): 15.80% Verizon 4.16% AT&T 5.97% Sprint 3.21%
Site Total MPE % : 29.14%
T-Mobile MPE % Per Sector
T-Mobile Sector A Total: 15.80% T-Mobile Sector B Total: 15.80% T-Mobile Sector C Total: 15.80%
Site Total MPE % : 29.14%
• NOTE: Totals may vary by approximately 0.01% due to summation of remainders in calculations.
T-Mobile Maximum MPE Power Values (Sector A)
T-Mobile Frequency Band / Technology (Sector A)
# Channels
Watts ERP (Per
Channel)
Height (feet)
Total Power Density
(µW/cm²)
Frequency (MHz)
Allowable MPE (µW/cm²)
Calculated % MPE
T-Mobile 2500 MHz LTE 1C & 2C Traffic
1 9619.47 117.0 28.07 2500 MHz LTE 1C & 2C
Traffic 1000 2.81%
T-Mobile 2500 MHz LTE 1C & 2C Broadcast
1 717.84 117.0 2.09 2500 MHz LTE 1C & 2C
Broadcast 1000 0.21%
T-Mobile 2500 MHz NR Traffic 1 19238.94 117.0 56.14 2500 MHz NR Traffic 1000 5.61%
T-Mobile 2500 MHz NR Broadcast 1 1435.69 117.0 4.19 2500 MHz NR
Broadcast 1000 0.42%
T-Mobile 1900 MHz GSM 4 1076.77 117.0 12.57 1900 MHz GSM 1000 1.26%
T-Mobile 1900 MHz LTE 2 2153.53 117.0 12.57 1900 MHz LTE 1000 1.26%
T-Mobile 2100 MHz LTE 2 2416.30 117.0 14.10 2100 MHz LTE 1000 1.41%
T-Mobile 600 MHz LTE 2 591.73 117.0 3.45 600 MHz LTE 400 0.86%
T-Mobile 600 MHz NR 1 1577.94 117.0 4.60 600 MHz NR 400 1.15%
T-Mobile 700 MHz LTE 2 648.82 117.0 3.79 700 MHz LTE 467 0.81%
Total: 15.80%
EBI Consulting
environmental | engineering | due diligence
21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311
Summary
All calculations performed for this analysis yielded results that were within the allowable limits for general population exposure to RF Emissions.
The anticipated maximum composite contributions from the T-Mobile facility as well as the site composite emissions value with regards to compliance with FCC’s allowable limits for general population exposure to RF Emissions are shown here:
T-Mobile Sector Power Density Value (%) Sector A: 15.80% Sector B: 15.80% Sector C: 15.80%
T-Mobile Maximum MPE % (Sector A):
15.80%
Site Total: 29.14%
Site Compliance Status: COMPLIANT
The anticipated composite MPE value for this site assuming all carriers present is 29.14% of the allowable FCC established general population limit sampled at the ground level. This is based upon values listed in the Connecticut Siting Council database for existing carrier emissions.
FCC guidelines state that if a site is found to be out of compliance (over allowable thresholds), that carriers over a 5% contribution to the composite value will require measures to bring the site into compliance. For this facility, the composite values calculated were well within the allowable 100% threshold standard per the federal government.