June 10th, 2022 Members of the Siting Council Connecticut Siting Council 10 Franklin Square New Britain, CT 06051 RE: Notice of Exempt Modification 123 Palmer Road, Chaplin, CT 06235 Latitude: 41.784528 Longitude: -72.135694 T-Mobile Site#: CT11508F - Anchor Dear Ms. Bachman: T-Mobile currently maintains six (6) antennas at the 117-foot level of the existing 146-foot monopole tower at 123 Palmer Road in Chaplin, CT. The 146-foot monopole tower is owned and operated by American Tower. The property is owned by the Janet Bessette Revocable Living Trust. T-Mobile now intends to remove and replace (3) antennas and add (3) antennas at the 117-foot level of the tower. These antennas will support 5G services. Planned Modifications: Tower: Install New: (3) Ericsson AIR 6419 B41 Antennas (3) Commscope VV-65A-R1 Antennas (3) Radio 4460 B25 B66 (2) 1.99” Hybrid Cables To Be Removed: (3) APX18 Antennas (3) Radio 4415s (3) KRY 112 489/2 TMAs (3) KRY 112 144/2 TMAs (12) 1 ” Coax
Transcript

June 10th, 2022

Members of the Siting CouncilConnecticut Siting Council10 Franklin SquareNew Britain, CT 06051

RE: Notice of Exempt Modification123 Palmer Road, Chaplin, CT 06235Latitude: 41.784528Longitude: -72.135694T-Mobile Site#: CT11508F - Anchor

Dear Ms. Bachman:

T-Mobile currently maintains six (6) antennas at the 117-foot level of the existing 146-foot monopole tower at123 Palmer Road in Chaplin, CT. The 146-foot monopole tower is owned and operated by American Tower.The property is owned by the Janet Bessette Revocable Living Trust. T-Mobile now intends to remove andreplace (3) antennas and add (3) antennas at the 117-foot level of the tower. These antennas will support 5Gservices.

Planned Modifications:Tower:Install New:(3) Ericsson AIR 6419 B41 Antennas(3) Commscope VV-65A-R1 Antennas(3) Radio 4460 B25 B66(2) 1.99” Hybrid Cables

To Be Removed:(3) APX18 Antennas(3) Radio 4415s(3) KRY 112 489/2 TMAs(3) KRY 112 144/2 TMAs(12) 1 ⅝” Coax

Ground:Install (1) 6160 Power Enclosure, and (1) B160 Battery Rack. Remove (6) RUS02 and (3) Diplexeres.

This facility was originally approved by the Council in Docket No. 211 on February 14, 2002. This modificationwill not break any of the conditions set forth in this approval.

Please accept this letter as notification pursuant to Regulations of Connecticut State Agencies§ 16- SOj-73, forconstruction that constitutes an exempt modification pursuant to R.C.S.A. § 16-50j-72(b)(2). In accordancewith R.C.SA. § 16-SOj-73, a copy of this letter is being sent to First Selectman Juan Roman III, Elected Official,and Jay Gigliotti, Zoning Enforcement Officer, as well as the tower and property owner.

The planned modifications to the facility fall squarely within those activities explicitly provided for inR.C.S;A. § 16-50j-72(b)(2).

1. The proposed modifications will not result in an increase in the height of the existing structure.

2. The proposed modifications will not require the extension of the site boundary.

3. The proposed modifications will not increase noise levels at the facility by six decibels or more, or to levelsthat exceed state and local criteria.

4. The operation of the replacement antennas will not increase radio frequency emissions at the facility to alevel at or above the Federal Communications Commission safety standard.

5. The proposed modifications will not cause a change or alteration in the physical or environmentalcharacteristics of the site.

6. The existing structure and its foundation can support the proposed loading.

For the foregoing reasons, T-Mobile respectfully submits that the proposed modifications to the abovereferenced telecommunications facility constitute an exempt modification underR.C.S.A. § 16-50j-72(b)(2).

Sincerely,

Eric BreunTranscend WirelessCell: 201-658-7728Email: [email protected]

Attachmentscc: Juan Roman III - First Selectman of ChaplinJay Gigliotti - Zoning Enforcement OfficerEverest Infrastructure Partners - Tower OwnerFrontier Communications - Property Owner

10 0 28 242 0

15 0 .0 1

20 0

20 0200

200

200

200

200

150

300

223.34

330

204

154111

268

19 3 .6 6 20 0 .2 8

36 5 .5 0

60 0

50

31 0

25 5

20 5

23 1 .3 5

21 0

11 6

21 0

21621285

357

488

206.72

206.72

548

92

22 5

27 7

20 0

20 0

20 0

20 0

27 2

31 8

222740 326 35023 024 524 7

200

249.73

578

220

245

15 0 .3 315 0

40 6 .0 222 0 .8 5

299

757

10 037 0

32 0

33 525 0

13 615 0 50 0 50 15 6 .5 5 30 0 11 8

311 25

91 510 0 25 7 22 5 16 4 21 6 .1 6

25 0

11 3 2

18 8.9

50 4.4 4

339.6

815

015

025

215

108

160

13 6

17 5

22 0

26 4

52

21 020 520 020 020 020 027 121 036 921 025 037 3

264

200

200

200

87

50 .8 8

154.55

71 0

69 0

53 9.2

13 0

561.8

212 .2

925

2 .3

209 .7

725

9 .04

150

150

351

7313 8

75 4

270

208

208

208

45 0

20 0

38 6539515 021 320 020 119 920 0606020 945 821 750

28 0

20 028 5

200

200

200200

200234.6

244.36

298

8 9 42

4 0 1 .8 5

2 2 5 .5

46

424

2 3 4

2 5 4

651

445

200

102

308±

170

200

150

275 0

1501 90

2 3 0

200

200

225

708

212

400

2 5 5

210307

2 05

202

317

403390

736

858

57

954

412

215216

192

329

241.7318

290.2

228 72

322155

155

109200

207

884

25 4 200 200

110100

40

160.3

111 .5 25

168

474

150

311

20 016 95652 010 04022 927 9

25 6

40 2 .8 4

20 0

58 0 .8 4

5021 0

42 8 .8 7

35 3 .2 2

79 .3 5

19 7.2 1

87 .4 723 7 .8 3

220

36 9323 9

20 5

21 0

21 0

21 0

20 6

24 0

31 5

20 415 0

33 924

3

23 .5 8 81 .3 5 10 0 .6 1 10 0 .6 124 3 .3 8

40 5 .6 7

446.84

10 0

23 4

234.11

10 342 0

210

450.96

20 0199.28

199.28

199.34

360.15

35 0

237.98

300.66

16 4 .7 1199.34

19 3 .3 8

199.34

267.67

37 6 .5

38 6 .3 5

111 4 .13

13 2 6 .6 1

13 3 7 .0 9

13 5 4 .1 7

32 430032 432 6 .8 9275.88

42 0 .3 3

26 7 .3

45 1 .7 3

80

198.62

62 7

34 1

70

18 6

20 0

89

25 5

27 4

14 0250

30 0

61 6

11 3 9

59

14 010 2

17 6

12557

151

22 9228

22 9

21 8

232.5

207.5

47 1 .1 3

72 6 .6 9

26 0 50 13 4

168

192

17095152151

291440

20 0

20 0

440

440

440

440

20 0

14 0

22 5 270

170

170

270

108176.14

120.13

390

35 8 .1 4

450

212.43

462.1

49 0 .6 9

67 3 .4 9

25 0 20 0452.45

449.78

440.84

15 1 .6 5

170.4

165.31

510 .4 632 5 .5 4

34 5 .5 5

750

1011.57

31 9 .9 6

352 .11

260 .28529.9

40

28 0

492.8

336.57

167.15

718.48

385.6394

300

300

31 0 300

654

335

25 8

372

865

470

180.12

701.42

25 2 .0 1

443.21

489.22

21 0420

43 4 .4 4

411 .9 8

540.96

18022 5

58

17 5 .8 3

24 1 31924 7

27 9

128

31229 6

294

87

16 1

17 0 170

204.09

301.56

436.17

250

595

114.98

748 135.25

14 0

82 8

31 9

21 9

99 .0

99 .0

107

10 7

23638 4 .5

150

150 100

36516 1

16 650

30

180

27 4

245

315

127

76 69.0

21725 0 270

27015 0

242

629.0

154

7015 6 .5 5

560

56 0

294

698

89 .011 8

329

366

36 1

23 2

35 6

927

37 5

200.31

67 1 .1 2

200

28 4

23 0

7121

0

30 222 2 54 .0 3

21 0

255

12 6

32531 9 .3 4

19 5 .1 4

12 6

12 5.0 6

49.7 7

775

775

22 5 19 0 .3 3

250

30 .2 5

59 .5 5

196.2

7

28 0 .5 6

24 6

70 0

44 4

43 2.6 3

12 7 .8 3 68 .030 .4 6

74 .2 2

11 8 .9 2

53.76

227 6

108 .9

416

9 .272

9 .15

258 .1

8

31 2 .4 3 14 7 .1 6

373 .0

2

26 8.7 4

18 1 .5

91 .9 9

261.6

13 1 .7

30 7 .6 3

408 .1

4

52 6 .0 7

65 9 .0 1 29 0

150

29 0

29 0

51 9

15 7.1 7

48 4.2 1

415 .6

5

28 7

59

203

29 3

30 0

12424 5

14 3

12 1

35 5

50

37 5

27 7

554

32 4

44 7

234

43 4

29 5

125

36 012 0

24 2

15 6

500

20 0

12 9 9

16 220 0

451

45 146 0

46 0

44 0

44 044 0

20 020 0

660

42 0

663

20 0

11 518 0

402

62 4

21 0 2

67 0

222

42 2

180

64

74 8

382

38 4

242

258

33 8

33 6

32 3

44 7

200

44 4

44 4

200

44 7

200

37 0

248.76

15 8

14 7

20 3

10 4

34 3

29 9 24 6 .8

259.2

28 0

30 0 32 5

33 6

18 5

41 2

45 2

30 2 .9 545 2 .8

20 2 .3

86.55

14 5 .1 7 56 7.2

15 7.3 5

14 5

561.8

14 6 .8 5

17 7 .2 4 10 0 24 0 .1 3

22 6 .1 6

181.18

152.45

25 6 .5 8

354 .7

6

83 .7 7

19 7.2 8

11 082 .8 317 5 .8 8

333.2 8

60 .1 5 13 1 .6 3

11 015 1 .0 3

15 0 .0 4

190 .2

3

35 8.7 1

34 3.4 423 2

.0 6

27 4 .0 6

17 0 .0 311 7 .8 2

11 2 .1 916 5 .2 4

119

15 023 1

84 3

83 3

90 9

31 2

260

311

203

30 1

31 2

208

208

31 224 316 5

36 7

31 9 20 5

23 2

34

64 2400

42 1

21 6

1867

1471

627

27 1211

60

667

1515

1527

42 0

20 4

310

117

55 0

39 8

237

19 9

434

43 9

20 0

440.1

44 0 .1

44 0 44 0

20 0 34 99

600 59 3

21 5 50

311

356

17 090

301

15 095

751

28 0

26 7

281

14 8

462

41 7

273

53

85

76

10 3

906 .93

9 0 7 .1 2

102

9 8 2 .2 6

9 9

325328.73 9 5 .2

294.1

257.2

2 6 7 .5

233223

272

718

9 67

807

427

684

118

2 0 9

117

1112

443

6 12

427

199

2 7 2

76 2 00

2 0 0

150

316

167

2 3 9

308

1 901 9 0150

200

4 01 9 4

1 5 4 200

1 4 1 1 4 5

351

199

260

324

1090

1170

3 7 0

190160

3 6 3

238

2 3 4

190

1 9 0

239

3 93

780

220

671891

2 9 1

242

5 4 6

37 5 0

75

1 4 3

173172 .89

2 1 2

4 5 1 .9 1

335.48

6 5 8 .9

510

6 6 0423±

641±

660

268

7 8

265 187

188

1 2 8 5 2 0 150

4 7 3

80

4 6 6

172 323

4 8 2 58

360

180

195

174

154

1 80

84 3 6 4

210

184187

3 6 5

135

564

36222

2 9 6570

310

385

16850

6 6

2 3 8

145

442

492

150

5 2 1

3 0 02 3 3

6 4 1

1263

96.0

1870

140 67

538

325

225

367

224 353

388

100

446

366

220

203

292

76

129 0

310

1550

1280.63

246 .06

464.84

264.45

492

172

506

396

306

208

416 104

150

746

27 7

446 303

214455

202

595

411

608

146

423

332

565

779

21521

217200

207

804

780

782

445

329

22

61

301

250

250

250

200 200

251 .7750

227.29

310 .97

479 .8 8

457 .87

132 .3534.3 4

200 .8890.6 8 100 .57

318.6

315

50

205 110

125

110

128

43225

189.2

374

59216

184

232

150

8 0 4

718

15 020 3

139

60

100

36 0

37 034 8

10 6

44 4 .9

23 7

10 0

285

20 0

10 0

20 0

230

55 0

80

24 038 4

860

29 0 11 0

25 4

22 4

718

364176

12 8

12 1 .0 6

93.5

10 7 .5 7 57 .2 412 5 .4 5

30 0

140 22 1

311

17 8

32 1

179

192

20 055 052 2

10 2

373

46 5

99 7

172

16 9

221

225

22 6

548

62 5

40 7.5 2

384230

53 8

35 7 .9 8

26 0 .2 4

14 9 .5

44 0

76 9 .1 8

15 8 .4 3

16 0

35 1 .8 7

11 026 2 .3 1

70

65 0

77 6 .9 9

12 9 .0 79013 4 .3 9

58 9 .0 8

42 0 .2 8

40 .6 2

37 5 .9 1

23 7 .3 8

23 9 .9 6

21 0

23 9 .9 6

65 .4 317 9 .1 9 17 9 .4 6

13 3 .2 4

10 0

56 4

17 0

275

250

50 1

33 0

22 0

34 2

440

29 4 67 7

29 3

69 6 .0

18 0

18 0

18 5

18 3

17 4

22 4

73 2

76 9

77 4

69 9 .0

21 7

15 0 260

43 1

50 8

35 020 755 4 43

2

55 0

44020 0

837

239.46

483.84

160.21

170.36287 .6 0

24 7 .2 514 2 .0 9

32 2 .1 5

212.04

767.79

474.77

73.5799.62

66.5793.39

94.61173.09

34 9 .3 214 5 .11

13 8 .4 173 .3 6

54 .7 4

22 4 .1 6

90 .5 530 .7 9

23 3 .5 9

147 .2 3

50

275

47 7.7 7

266 .9 5

285 .4

1

122 .4

5

568 .9

555

0 .64

719.0

4

24 4 .1 0 20 8 .4 4 16 8 .7 3 43 5 .4 0

70 .6 2 13 2 .9 1 20 5 .3 9 58

17 8 .7 4

38 .1 9

74.5 9

101 .3

917

9.10

11 7.8 1

47 3.1 7

Ross Rd

Linkkila LnMansfield

MansfieldMansfield

#125

#48

#122

#123

#360

#41

#49

#90 #31

#108

#111

#75

#222

#164

#288

#87

#240

#20

#63

#124

#176

#179

#120

#88

#101

#12

#8

#156

#171

#128

#66

#18

#57#203

#166

#278

#176

#26

#5

#232

#45

#146

#278

#21

#41

#51

#138

#112

#167

#67

#9

#20

#188#41

#69

#39

#8

#119

#17

#318

#75

#187

#195

#12

#184

#29

#56

#49

#119

#203

#11

#97

#41

#93

#21

#82

#137

#6

#117 & 95

#222

#18

#23

#47

#147

#68

#54

#18

#149

#100 #4

#175

#85

#241

#84

#15

#49

#109

#55

#188

#150

#193

#242

#50

#55

#63

#196

#19

#12#177

#171

#273

#5

#111

#93

#21

#65

#342

#13

#275

#192

#151

#263

#114

#32

#235

#69

#239

#171

#85

#150

#156

#304

#27

#189

#101

#69

#122

#109

#92

#211

#24

#80

#340

#92

#287

#35

#106

#250

#97

#45

#110

#322

#93

#99

#106 #78

#63

#251

#64

#20

#202

#26+30

#76

#27

#5

#280

#268

#150

#216

#58#66

#298

#28

#195

#80

#82

#216

#50

#323

#91

#168

#73

#25

#83

#215

#281

#315

#304

#74

#116

#311

#140

#212

#34

#139

#61

#149

#171

#160

#117

#28

#64

#85

#245

#13

#98

#9

#109

#9

#129

#144

#145

#134 #325

#121

#161

#10

#219

#147

#122

#209

#182

#179

#292

#161

#120

#251

#210

#204

#267

#259

#201

#181

#207

#186#239

#152

#153

#36

#330

#241

#129#310

#140

#85

#334

#135

#3

#22

#60

#28

#135

#133

#315

#22

#19

#170

#200

#16

#39 #29

#290

#376

#179

#51

#301

#184

#50

#295

#303

#18

#123

#42

#225

#262

#200

#187

#219

#214

#284

#47 #44

#260

#310

#256

#96

#184

#288

#12

#109

#36

#262

#114

#267

#43

#264

#258

#159

#31

#222

#244 #234

#223

#35

#2

#54

#350

#227#221

#203

#177

#144

#77

#106

#190

#405

#176

#57

#11

#46

#96

Stonehouse Brk

Natchaug RivNatchaug Riv

Natchau

g Riv

St onehouseBrk

Stonehouse Brk

Tu rne r B rk

Na tchaug R iv

Bu ttonball B rk

Turner Brk

Stonehouse Brk

Federal Rd

N Bedlam Rd

Miller Rd

Phoe

n ixv il l

e Rd

Palmer Rd

Bedlam Rd

S Bear Hill Rd

Ridge Rd

Canada Ln

England Rd

York Rd

Dianas Pool Rd

S Bear Hill Rd

S Bear Hill Rd

Palme

r Rd

Pa lm er R d

Ridge Rd

Phoe

n ixv il l

e Rd

P hoen

ix vil le

R d

S Bear H ill Rd

Cross Rd

Bedlam Rd

N Bedlam RdS Bedlam Rd

N Bedlam Rd

Palmer Rd

Bedlam Rd

Bedlam Rd

Davis Rd

Chaplin St

Palmer Rd

England Rd

Phoenixville Rd

Pa lmer Rd

Hall R

d

Mountain Laurel Ln

Davis Rd

Feder

al Rd

N Bedlam Rd

S Bedl

am Rd

Canada

Ln

Davis Rd

Miller Rd

55-37

55-32

55-54

55-34-1

55-57

55-27

55-42

55-48-2

55-3

55-61-2

55-41

55-7

55-3

55-8

55-53-8

55-49

55-61

55-53-6

55-13

55-49-1

55-3-2

55-5055-15

55-54-8

55-57-1

55-34

55-31

55-52

55-4755-14

55-56

55-14-1

55-56-1

55-24

55-36

55-44

55-24-2

55-54-2

55-9

55-30

55-27-A

55-3555-33

55-51-1

55-38

55-58

55-24-1

55-53-9

55-48-1

55-10

55-40

55-11

55-53-5

55-8-3

55-63

55-2

55-44-2

55-47-3

55-62

55-16

55-6

55-43

55-53-7

55-46

55-20

55-4

55-44-3

55-5555-12

55-54-5

55-60

55-44-1

55-48-3

55-39

55-17

55-61-1

55-62-1

55-47-1

55-54-3

55-26-1

55-54-6

55-19

55-47-4

55-61-3

55-18

55-47-2

55-53-3

55-51-2

55-53-1

55-53-2

55-53-4

55-8-1

55-54-4

55-48-4

55-55-2

55-25

55-54-1

55-26

55-23-155-8-5

55-8-2

55-20-2

55-8-7

55-8-6

55-23

55-45

55-20-1

55-8-8

55-59

55-29-155-1

55-22

55-28

55-5

55-30-1

55-29

!

55-21

!

55-50-1

!

55-43-1

!

55-12-1

82.13 AC

10.23 AC

9 AC

21 AC

42.75 AC 68.04 AC

2 AC

4 AC

26.5 AC

21.3 AC

12 AC

31.35 AC

18.5 AC

5 AC

5 AC

10 AC

25.5 AC

3 AC

9.5 AC

3 AC

3 AC10.4 AC

25.5 AC

6.5 AC

2 AC7.9 AC

2 AC 2 AC

2 AC

2 AC

2 AC

5.7 AC

2 AC

15.29 AC2 AC

3.7 AC

2 AC

11.25 AC

10.05 AC

2 AC

3.9 AC

5.47 AC

2.9 AC

10.66 AC

3.7 AC3.6 AC

2.83 AC

4.22 AC

1 AC

3.53 AC

2.9 AC

3.92 AC

8.9 AC 2.9 AC

7.16 AC

1 AC

3.02 AC

1 AC

3.37 AC

6.41 AC

2.1 AC

8.4 AC

1.7 AC

3.67 AC

4.41 AC

2.55 AC4.71 AC

2.38 AC

1.8 AC

1.6 AC

4.01 AC

1.7 AC

2.02 AC

2.23 AC

1.5 AC

4.31 AC

4.01 AC

2.07 AC1.5 AC

1.3 AC

2.03 AC

2.03 AC

3.01 AC1.98 AC

2.02 AC2.13 AC

1.75 AC

1.4 AC

2.13 AC

1.1 AC

1.57 AC

1.2 AC

2.61 AC

3.06 AC

2.56 AC

36.05 AC

1.33 AC

1.1 AC

2.29 AC

1.5 AC

2.31 AC

1.17 AC

1.3 AC

1.23 AC

2.29 AC

2.04 AC

2.04 AC

2.04 AC

0.6 AC

2.08 AC

2.04 AC

0.5 AC

0.55 AC

0.4 AC

0.7 AC

0.2 AC

0.49 AC

0.06 AC 0.01 AC

75 -66

57 -26 -2

75 -43

89 -30

57 -30

53 -29

53 -40

73 -34

73 -46

89 -23

71 -2

75 -44

57 -35

53 -80

57 -10

57 -26

73 -60

57 -36

53 -1-3

57 -29

57 -32

53 -90

73 -50 -1

53 -26

53 -76 -1

57 -36 -1

73 -1

53 -59

53 -28

73 -3873 -49

73 -2

53 -67

57 -24

91 -25 -2

57 -1

53 -76

91 -148

57 -37

53 -57 -1

91 -145

53 -27

91 -137 -4

91 -137 -3

57 -2

53 -58

53 -28 -1

57 -34

53 -25

57 -23

53 -67 -3

53 -37

73 -6

57 -39

91 -137 -1

53 -36

53 -35

53 -34

91 -137

75 -11

73 -4-1

57 -23 -1

53 -6

57 -37 -3

57 -27 -1

57 -28

91 -140

53 -33

73 -45 -5

53 -74

53 -24

73 -5-2

73 -3

73 -7

73 -4

91 -155

57 -29 -1

91 -126

53 -51

73 -45

53 -54

53 -50

73 -5-3

57 -30 -2

57 -37 -2

57 -30 -1

53 -67 -2

57 -21 -5

57 -21 -7

57 -8

53 -59 -1

53 -26 -2

53 -14

53 -44

93 -16 -4

57 -3853 -52

57 -28 -1

53 -32

91 -150 -4

57 -21 -6

53 -30 -2

75 -40 -1

75 -39

89 -25

57 -1153 -63 -1

71 -3

91 -147

91 -141

73 -5-1

53 -24 -1

53 -5

53 -48

73 -50

73 -47

57 -5-1

53 -21

93 -16 -1

53 -1

53 -76 -2

57 -21 -4

91 -144

53 -8

53 -4

53 -9

53 -20

53 -7

53 -30 -4

53 -68

91 -150 -1

57 -27

53 -18

57 -15

75 -37

91 -147 -1 91 -131

57 -21 -3 93 -16 -14

53 -30 -1

53 -60

57 -12

53 -12

89 -23

53 -38

93 -16 -11

57 -18

57 -21 -2

75 -1273 -35

93 -16 -2

73 -50 -2

53 -17

93 -16 -16

93 -16 -12

53 -11

91 -139 -1

53 -70

53 -57

53 -77

53 -23

53 -39

57 -21 -1

71 -1

75 -1

93 -16 -3

53 -1553 -19

73 -46 -1

53 -13

53 -3

53 -16

53 -17 -1

73 -7-1

93 -16 -13

93 -16 -5

53 -66

93 -16 -15

73 -47 -1

53 -47

57 -26 -3 53 -31

53 -28 -4

57 -37 -1

75 -28

91 -130

53 -53

53 -46

57 -26 -4

75 -29

57 -36 -2

73 -48

93 -16 -10

91 -137 -2

75 -40

91 -137 -5

53 -28 -2

91 -150 -2

53 -30 -3

53 -45

53 -40 -1

57 -41

53 -30 -5

75 -9

53 -59 -2

57 -24 -4

57 -4057 -14

53 -26 -1

57 -13

57 -24 -3

57 -24 -5

57 -25

93 -16 -9

73 -45 -4

53 -62 -1

57 -9

57 -7

53 -71

75 -7

53 -65

53 -26 -3

57 -6

57 -22

53 -72

53 -43

91 -27

53 -67 -3A

53-42

93 -78

75 -43 -2

53 -81 -3

53 -20 -1

53 -79

53 -22

75 -38

75 -4

91 -131 -1

73 -36 73 -37

53 -20 -2

75 -32

91 -137 -A

75 -5

57 -37 -4

57 -4

91 -146

91 -143

91 -151

75 -8-1

53 -6453 -55

75 -2

91 -129

73 -44 -2

57 -24 -1

91 -133

93 -16

91 -136

75 -34

57 -26 -1

91 -138

73 -44 -1

75 -36

57 -19

75 -8

53 -10

57 -31

91 -14991 -150 -3

57 -33

57 -3

53 -7553 -73

75 -33

53 -41

53 -70 -1

91 -142

57 -16

57 -44

75 -42

53 -18 -1

53 -61

73 -44

53 -62

75 -6

75 -35

53 -2

91 -128

75 -10

57 -24 -2

93 -15

75 -31

57 -5

53 -69

91 -153

57 -43

73 -43

53 -81 -4

93 -16 -6

53 -67 -4

91 -152

57 -42

75 -30

53 -83

75 -41

91 -149 -1

73 -45 -173 -45 -3

91 -160

91 -127

75 -3

53 -89

M A P N O .

55100 0 100 200 30050M E TE R S

400 0 400 800 1,200200FE E T

R EV ISED TO :

TH IS M A P IS FO R A S S E S SM E N T P U R P O S E S . IT IS N O T VA LID FO R L E G A L D E SC R IP T IO N O R C O N V EYA N C E .

TH E H O R IZ O N TA L D ATU M IS T H E C O N N E C TIC U T S TAT E P L AN EC O O R D IN ATE SY S T E M , N A D 8 3.

OC TO B ER 1, 2021

PR O P E RTY M AP S

C H APLINC O N N E C TIC U T

SC ALE : 1" = 400 'LEGENDPA R C EL AR E A 5.1 ACD IM EN SIO N 365SC ALED D IM EN S IO N 100±

EASE M EN T

TO W N L IN E

STR E AM

IN TE R M ITT EN T S TR EA M

C O N D O M IN IU M

W ATER BO D YC O M M O N O W N E R SH IP

IN D E X D IA G R A M

55

02

4 6 8

515557

71 7375

77

89 91 93

53 ³11 P leasant S tree t, Littleton , N H 03561800.322.4540 - w w w.ca i-tech .com

R E V I S E D A N D R E P R I N T E D B Y

Other ID: 55-54

CURRENT OWNER TOPO. UTILITIES STRT./ROAD LOCATION CURRENT ASSESSMENTDescription Code Appraised Value Assessed Value

SUPPLEMENTAL DATA

RES LAND 1-1 25,300 17,700

Total 25,300 17,700

CHAPLIN, CT6024

BESSETTE JANET L REVOCABLE LIVING TRUST

5 VICTORY LN

WILLIMANTIC, CT 06226Additional Owners:

VISIONGIS ID:

BK-VOL/PAGE SALE DATE q/u v/i SALE PRICE V.C. PREVIOUS ASSESSMENTS (HISTORY)102/ 97187/ 97660/ 633

10/03/201601/09/200701/25/1996

UU

VVV

000

010600

EXEMPTIONS OTHER ASSESSMENTS This signature acknowledges a visit by a Data Collector or AssessorYear Description Amount Code Description Number Amount Comm. Int.

APPRAISED VALUE SUMMARY

NOTES

Net Total Appraised Parcel Value 25,300

000

25,3000

25,300

Appraised Bldg. Value (Card)

RECORD OF OWNERSHIP

2015-ADJ ACREAGE PER SURVEY MAPVOL 12 PG 14

BESSETTE JANET L REVOCABLE LIVING TRUSTBESSETTE JANET L

2016-REMOVED COMMERICAL LAND

LESSEE RESPONSIBLE

CELL TOWER LAND LEASE VALUE= 1500 X 12=

18,000-(10% EXP)=16,200/.09 CAP= 180,000

C

BUILDING PERMIT RECORDPermit ID Issue Date Type Description Amount Insp. Date % Comp. Date Comp. Comments Date ID Cd. Purpose/Result18-67E18-54E

10/26/201810/09/2018

ELEL

ElectricElectric

13,50020,000

00

GENERATORANTENNAS REPL

04/24/201802/16/2016

JWAO

4145

Change - Field ReviewChange - Value Change Town

LAND LINE VALUATION SECTION

Census Tr.Survey #

DV Map #Call Back

DV Lot #

X

Appraised XF (B) Value (Bldg)Appraised OB (L) Value (Bldg)Appraised Land Value (Bldg)Special Land Value

Total Appraised Parcel ValueValuation Method:

Total:ASSESSING NEIGHBORHOOD

Type ISVISIT/ CHANGE HISTORY

ASSOC PID#

Adjustment: 0

Type

Yr. Code Assessed Value Yr. Code Assessed Value Yr. Code Assessed Value1-1 22,900 2012 6-2 8,400 2008

20082008

1-11-15-2

159,000104,900

45,900

Total: 22,900 Total: Total:

2017

NBHD/ SUB0001/A

NBHD Name Street Index Name Tracing Batch

8,400 309,800

B#11

Total Card Land Units:

100100

Use Code

UseDescription

Resid VacantResid Vacant

Zone D Front Depth2.008.23

UnitsACAC

AC10.23 Parcel Total Land Area:

3,100.003,100.00

1.00001.0000

I.Factor

Unit Price S.A.

00

10.23 AC

1.00001.0000

AcreAcre

C.Factor

1.000.75

ST.Idx Adj.

0.000.00

Total Land Value:

TOPO

Notes- AdjSpecial Pricing

Adj. Unit Price Land Value6,200

19,100

25,300

DiscDisc

Property Location: 123 PALMER RD MAP ID: 55/ 54/ / /Bldg #: 1 of 1 Card 1 of 1 Print Date: 12/11/2018 12:41Vision ID: 622 Account #

Parcel DescriptionB000626

Bldg Name: State Use: 100Sec #: 1 ofof 1

S AdjFact

1.001.00

Spec Use Spec Calc

No Photo On Record

Model

CONSTRUCTION DETAILElement Cd. Ch. Description

COST/MARKET VALUATION

BUILDING SUB-AREA SUMMARY SECTIONCode

Ttl. Gross Liv/Lease Area:

OB-OUTBUILDING & YARD ITEMS(L) / XF-BUILDING EXTRA FEATURES(B)

00 Vacant

MIXED USE

Element Cd. Ch. DescriptionCONSTRUCTION DETAIL (CONTINUED)

Property Location: 123 PALMER RD MAP ID: 55/ 54/ / /Bldg #: 1 of 1 Card 1 of 1 Print Date: 12/11/2018 12:41Vision ID: 622 Account #

Parcel DescriptionB000626

Bldg Name: State Use: 100Sec #: 1 ofof 1

Code100

DescriptionResid Vacant

Percentage100

Description Living Area Gross Area

0 0

Eff. Area Unit Cost Undeprec. Value

Adj. Base Rate: 0.00

AYB

Dep CodeRemodel RatingYear RemodeledDep %Functional ObslncExternal ObslncCost Trend FactorCondition% CompleteOverall % CondApprais ValDep % OvrDep Ovr CommentMisc Imp OvrMisc Imp Ovr CommentCost to Cure OvrCost to Cure Ovr Comment

0

0

0

Code SubDescription Sub Descript L/B Units Unit Price Yr Gde Dp Rt Cnd %Cnd Apr Value

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

G-001

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

TITLE SHEET

0 FOR CONSTRUCTION ADE 06/02/22

0

LOCATION MAPVICINITY MAP

Know what's below. Call before you dig.

R

COMPLIANCE CODE PROJECT SUMMARY PROJECT DESCRIPTION

UTILITY COMPANIES

SHEET INDEXSHEET

NO: DESCRIPTION: REV: DATE: BY:

G-001 TITLE SHEET 0 06/02/22 ADE

G-002 GENERAL NOTES 0 06/02/22 ADE

C-101 DETAILED SITE PLAN 0 06/02/22 ADE

C-102 DETAILED GROUND PLAN 0 06/02/22 ADE

C-201 TOWER ELEVATION 0 06/02/22 ADE

C-401 ANTENNA INFORMATION & SCHEDULE 0 06/02/22 ADE

C-501 CONSTRUCTION DETAILS 0 06/02/22 ADE

E-501 GROUNDING DETAILS 0 06/02/22 ADE

R-601 SUPPLEMENTAL

R-602 SUPPLEMENTAL

R-603 SUPPLEMENTAL

R-604 SUPPLEMENTAL

R-605 SUPPLEMENTAL

R-606 SUPPLEMENTAL

R-607 SUPPLEMENTAL

MOUNT MODIFICATION SHEETS

SITE LOCATION

SITE ADDRESS:

123 PALMER ROAD

CHAPLIN, CT 06235-2416

COUNTY: WINDHAM

GEOGRAPHIC COORDINATES:

LATITUDE: 41.784528

LONGITUDE: -72.135694

GROUND ELEVATION: 504' AMSL

ATC SITE NAME: CT CHAPLIN SOUTH CTATC SITE NUMBER: 411216T-MOBILE SITE NAME: CT508//VERIZON CHAPLINT-MOBILE SITE NUMBER: CT11508FSITE ADDRESS: 123 PALMER ROAD

CHAPLIN, CT 06235-2416

PROJECT TEAM

TOWER OWNER:

AMERICAN TOWER10 PRESIDENTIAL WAY

WOBURN, MA 01801

PROPERTY OWNER:

JANET L BESSETTE123 PALMER ROAD CHAPLIN, CT 06235

ENGINEER:

POWER OF DESIGN GROUP, LLC11490 BLUEGRASS PKWY

LOUISVILLE, KY 40299

POWER COMPANY: NORTHEAST UTILITY SERVICESPHONE: (800) 592-2000

TELEPHONE COMPANY: UNKNOWNPHONE:UNKNOWN

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

PROJECT LOCATION DIRECTIONS91N-WILBUR CROSS HWY CT-15 VIA EXIT 29 TOWARDS I-84/E

HARTFORD/BOSTON. CT -15N/WILBUR CROSS HWY BECOMESUS-6E/I-84/WILBUR CROSS HWY 1.6 MI/MERGE ONTO I-384 E VIA EXIT59 TOWARD PROVIDENCE 8.5 MI/TURN SLIGHT LT ONTO US-6/CT-66.CONTINUE TO FOLLOW US-6 E9.2 MI. TURNLT ONTO PHOENIXVILLERD/CT-198 1.2 MI/TURN LT ON RIDGE RD. TURN LT ON PALMER RD.SITE IS THE SECOND DRIVEWAY ON THE LT AFTER WHITE HOUSEMAILBOX #119. GATE COMBO 4667. T1'S MOUNTED IN OUTDOOR

HOFFMAN BOX

1. THE FACILITY IS UNMANNED.2. A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE

A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE.3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND

DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE.4. NO SANITARY SEWER, POTABLE WATER OR TRASH

DISPOSAL IS REQUIRED.5. HANDICAP ACCESS IS NOT REQUIRED.6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS

AN ELIGIBLE FACILITIES REQUEST ENTITLES TOEXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS AMODIFICATION OF AN EXISTING WIRELESS TOWER THATINVOLVES THE COLLOCATION REMOVAL AND/ORREPLACEMENT OF TRANSMISSION EQUIPMENT THAT ISNOT SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (B)(7).

PROJECT NOTES

THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASEDAND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW:

REMOVE (3) ANTENNA(s), (3) RRU(s), (6) TMA(s), AND (12) COAXCABLE(s)

INSTALL (6) ANTENNA(s), (3) RRU(s), (2) HYBRID CABLE(s) ANDMOUNT MODIFICATIONS

EXISTING (3) ANTENNA(s), (3) RRU(s), AND (1) HYBRID CABLE(s) TOREMAIN

GROUND WORK:

EXISTING (1) RBS 6201 ODE CABINET, (2) BB 6630, AND (1) DUG20 TOREMAIN

INSTALL (1) ERICSSON 6160 CABINET, (1) B160 CABINET, (2) RP 6651,(1) PSU 4813 vR4A VOLTAGE BOOSTER, (1) CSR IXRE V2 ROUTERAND POWER CONDUIT FROM EXISTING PPC TO PROPOSED 6160CABINET

REMOVE (6) RUS02 B2 AND (3) DIPLEXERS

ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLEDIN ACCORDANCE WITH THE CURRENT EDITIONS OF THEFOLLOWING CODES AS ADOPTED BY THE LOCALGOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS ISTO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TOTHESE CODES.

1. 2018 CT STATE BUILDING CODE/ 2015 IBCW/ CT AMENDMENTS

2. 2018 CT STATE BUILDING CODE/ 2017 NECW/ CT AMENDMENTS

3. LOCAL BUILDING CODE4. CITY/COUNTY ORDINANCES

APPLICANT:

T-MOBILE4 SYLVAN WAY

PARSIPPANY, NJ 07054

T-MOBILE ANCHOR AMENDMENT PLAN67D5D998E ODE+6160 CONFIGURATION

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

G-002

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

GENERAL NOTES

0 FOR CONSTRUCTION ADE 06/02/22

0

GENERAL CONSTRUCTION NOTES:1. OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THE

CONTRACTOR WILL INSTALL

A. BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUNDBUILD/CO-LOCATE ONLY)

B. AC/TELCO INTERFACE BOX (PPC)C. ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC

TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION)D. TOWERS, MONOPOLESE. TOWER LIGHTINGF. GENERATORS & LIQUID PROPANE TANKG. ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTINGH. ANTENNAS (INSTALLED BY OTHERS)I. TRANSMISSION LINEJ. TRANSMISSION LINE JUMPERSK. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITSL. TRANSMISSION LINE GROUND KITSM. HANGERSN. HOISTING GRIPSO. BTS EQUIPMENT

2. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THECOMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCHMATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FOR PLATFORM,ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES,COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS ANDDISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER,CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS ANDRUBBER MATTING, REBAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS,MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES ANDALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TOTHE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FORPERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIREDPERMITS.

3. ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCALCODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTIONSPECIFICATIONS.

4. CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUNDUTILITIES PRIOR TO START OF CONSTRUCTION.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIREDINSPECTIONS.

6. ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, ANDSITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALLDISCREPANCIES REPORTED TO THE ENGINEER.

7. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS.

8. DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESSOTHERWISE NOTED.

9. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTIONSAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.

10. CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDEDFOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING,ANCHOR BOLTS, ETC.

11. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDSDRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK.

12. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING ORNONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILEREP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALLREQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING.

13. EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HISWORK WITH THE WORK OF OTHERS.

14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THISPROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTIONOF THE T-MOBILE CONSTRUCTION MANAGER.

15. ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURINGINSTALLATION USING A SILICONE SEALANT.

16. WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET,CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORDIMMEDIATELY.

17. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETEAND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT.

18. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OFEACH DAY.

19. CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWERCORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OFOTHER OCCUPANTS OF THE FACILITY.

20. CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC)WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK.

21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDEDSHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALLALL ITEMS PROVIDED.

22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIREDPERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THECONTRACTOR.

23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILESPECIFICATIONS AND REQUIREMENTS.

24. CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW ANDAPPROVAL PRIOR TO FABRICATION.

25. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'SSPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND ASSHOWN IN THESE PLANS.

26. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTIONMEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FORCOORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.

27. CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OFPOURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS ORSEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW ANDAPPROVAL.

28. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITHALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALLNECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICESSUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING,TRENCH BOXES/SLOPING, BARRIERS, ETC.

29. THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES ANDSUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANYDAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HISREPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THISCONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HISWORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HISEXPENSE TO THE OWNER'S SATISFACTION.

30. ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNERBY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIPSHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BYTHE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BEREPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL ISOBTAINED.

31. IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OFMATERIALS LISTED HEREINAFTER BY MANUFACTURER’S NAMES AND/ORMANUFACTURER’S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERSAS SPECIFIED.

32. T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE WAREHOUSE,NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTEDAND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACETHE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BERESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP.

33. T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANYEQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITHTHE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THEEQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THEREQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TOT-MOBILE OR THEIR ARCHITECT/ENGINEER.

SPECIAL CONSTRUCTIONANTENNA INSTALLATION NOTES:

1. WORK INCLUDED:

A. ANTENNA AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER ASEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNAINSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS.ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OFPERSONNEL.

B. INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILESPECIFICATIONS.

C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS.

D. INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE.

E. CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USINGANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCYDOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER.SWEEP TESTS SHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTINGRECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICEAND BE BOUND AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION.

F. INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS ANDEQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALLCONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'SREQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OFENTRY PORT LOCATION UNLESS OTHERWISE STATED.

G. ANTENNA AND COAXIAL CABLE GROUNDING:

2. ALL EXTERIOR #6 GREEN GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BEWEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OREQUAL.

3. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF

COAXIAL CABLE (NOT WITHIN BENDS)

ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESECONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATCENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN.

FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING ORANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR

APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLERESPONSIBILITY OF THE GENERAL CONTRACTOR.

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S 0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S 0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S 0D2908-SM4X15STUD 0D2908-SM4X15STUDM6X200C8112A-S

X X

X X X X X X

XX

XX

XX

XX

XX

XX

XX

XX

X

XXXXXXXXXXXXXXXXX

XX

XX

XX

XX

XX

XX

XX

XX

X

X X X X X X X X X

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

C-101

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

DETAILED SITE PLAN

0 FOR CONSTRUCTION ADE 06/02/22

0

1 DETAILED SITE PLAN

GRAPHIC SCALE

( IN FEET )1 UNIT = 10 FEET

105010

SITE PLAN NOTES:

1. THIS SITE PLAN REPRESENTS THE BESTPRESENT KNOWLEDGE AVAILABLE TO THEENGINEER AT THE TIME OF THIS DESIGN. THECONTRACTOR SHALL VISIT THE SITE PRIOR TOCONSTRUCTION AND VERIFY ALL EXISTINGCONDITIONS RELATED TO THE SCOPE OF WORKFOR THIS PROJECT.

2. ICE BRIDGE, CABLE LADDER, COAX PORT, ANDCOAX CABLE ARE SHOWN FOR REFERENCEONLY. CONTRACTOR SHALL CONFIRM THEEXACT LOCATION OF ALL PROPOSED ANDEXISTING EQUIPMENT AND STRUCTURESDEPICTED ON THIS PLAN. BEFORE UTILIZINGEXISTING CABLE SUPPORTS, COAX PORTS,INSTALLING NEW PORTS OR ANY OTHEREQUIPMENT, CONTRACTOR SHALL VERIFY ALLASPECTS OF THE COMPONENTS MEET THE ATCSPECIFICATIONS.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTORTO COORDINATE WITH THE T-MOBILEREPRESENTATIVE AND LOCAL UTILITY COMPANYFOR THE INSTALLATION OF CONDUITS,CONDUCTORS, BREAKERS, DISCONNECTS, ORANY OTHER EQUIPMENT REQUIRED FORELECTRICAL SERVICE. ALL ELECTRICAL WORKSHALL BE PERFORMED IN ACCORDANCE WITHLATEST EDITION OF THE STATE AND NATIONALCODES, ORDINANCES AND REGULATIONSAPPLICABLE TO THIS PROJECT.

LEGEND

AUTOMATIC TRANSFER SWITCHATS

DISCONNECTDELECTRICALEFIBERF

BOLLARDB

GENERATOR RECEPTACALGHAND HOLE, VAULTHH, VICE BRIDGEIBKENTROX BOXK

GENERATORGEN

METERMLIGHTING CONTROLLC

PULL BOXPBPOWER POLEPPTELCOTTRANSFORMERTRN

X CHAINLINK FENCE

GROUNDING TEST WELL

CELL SITE CABINETCSC

PROPOSED CABLE LENGTH:

1. ESTIMATED LENGTH OF PROPOSED CABLE IS 172'.ESTIMATED LENGTH OF CABLE WAS PROVIDED BYCUSTOMER OR CALCULATED BY ADDING THE RADCENTER AND THE DISTANCE FROM THE SHELTERENTRY PLATE TO THE TOWER (ALONG THE ICEBRIDGE) AND A SAFETY FACTOR MEASUREMENT OF15% (OF THE TWO PREVIOUS VALUES), CDS DEFERTO GREATEST CABLE LENGTH.

2. ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. IF ADEQUATE SPACEEXISTS, ROUTE CABLES THROUGH ENTRY PORTHOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXITPORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE,ATTACH CABLES USING STAND-OFF ADAPTERSMOUNTED TO TOWER USING STAINLESS STEELBANDING. ADEQUATELY SECURE CABLES USINGEITHER APPROPRIATELY SIZED STAINLESS STEELSNAP-INS OR MOUNTING HARDWARE AND BRACKETSAS SPECIFIED BY CABLE MANUFACTURER.

(12) 1 5/8" COAX CABLES(TO BE REMOVED)

(MODIFIED AS REQUIRED FOR UPGRADEFROM 67D94E TO 67D5D998E ODE+6160CONFIGURATION)

PROPOSED (2) 6X24 4AWG (1.99") HYBRID CABLES(ROUTED PER PROPOSED CABLE LENGTH NOTE 2)

(REFER TO PROPOSED CABLE LENGTH NOTE ON THIS PAGE)

1R-601

2C-102

4E-501

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

C-102

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

DETAILED GROUNDPLAN

SITE PLAN NOTES:

1. CONTRACTOR TO VERIFY THERE IS NO LIVE AAV FIBER RUNNING THROUGH EXISTING DEADEQUIPMENT. IF SO, THIS WILL NEED TO BE RERUN THROUGH CONDUIT PRIOR TO REMOVINGDEAD 2G (6201 CABS) EQUIPMENT.

2. ALL OPEN PORTS NEED TO BE SEALED / WEATHERPROOFED PROPERLY

3. ALL UNNEEDED / EXCESS EQUIPMENT AND GARBAGE TO BE REMOVED FROM EQUIPMENT AREA.DISPOSE OF MATERIALS PROPERLY OFF SITE.

T-MOBILE CM APPROVAL REQUIRED BEFORE INSTALLING CABINETS.ALL ABOVE GROUND CONDUIT LESS THAN 6" CAN BE LFMC.ALL ABOVE GROUND CONDUIT OVER 6" MUST BE RGS.ALL PVC CONDUIT MUST BE BURIED.

1 EXISTING GROUND EQUIPMENT LAYOUT 2 PROPOSED GROUND EQUIPMENT LAYOUT

GRAPHIC SCALE55

( IN FEET )1 UNIT = 5 FEET

0 2.5GRAPHIC SCALE

55

( IN FEET )1 UNIT = 5 FEET

0 2.5

(12) 1 5/8" COAX CABLES(TO BE REMOVED)

PROPOSED(2) 6X24 4AWG (1.99")HYBRID CABLES

(TO BE REMOVED)

(3) EXISTING DIPLEXERS(TO BE REMOVED)

PROPOSED ENCLOSURE6160 CABINET

1R-604

PROPOSED B160BATTERY CABINET

1R-606PROPOSED (2) RP 6651, (1) PSU

4813 vR4A VOLTAGE BOOSTER,AND (1) CSR IXRE V2 ROUTER

1R-603

1R-605

1'-0"8"

PROPOSED POWER CONDUITFROM EXISTING PPC TO

PROPOSED 6160 CABINET

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

C-201

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

TOWER ELEVATION

0 FOR CONSTRUCTION ADE 06/02/22

01 TOWER ELEVATIONSCALE: N.T.S.

TOWER NOTE:1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO

CONFIRM WITH THE PROJECT MANAGER THATTHEY HAVE THE MOST RECENT VERSION OF THESTRUCTURAL ANALYSIS BEFORE COMMENCINGWORK. EXISTING AND PROPOSED TOWERAPPURTENANCES, MOUNTS, AND ANTENNAS ARESHOWN BASED ON THE STRUCTURAL ANALYSIS.

2. WHERE APPLICABLE, ALL NEW ANTENNAS,EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BEPAINTED/SOCKED TO MATCH EXISTING EQUIPMENTIN ACCORDANCE WITH FAA, JURISDICTION, AND/OROTHER LOCAL REQUIREMENTS.

3. ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. IF ADEQUATE SPACEEXISTS, ROUTE CABLES THROUGH ENTRY PORTHOLE, UP INSIDE OF MONOPOLE, AND THROUGHEXIT PORT HOLE. IF ROUTING OUTSIDE THEMONOPOLE, ATTACH CABLES USING STAND-OFFADAPTERS MOUNTED TO TOWER USING STAINLESSSTEEL BANDING. ADEQUATELY SECURE CABLESUSING EITHER APPROPRIATELY SIZED STAINLESSSTEEL SNAP-INS OR MOUNTING HARDWARE ANDBRACKETS AS SPECIFIED BY CABLEMANUFACTURER.

4. TOWER ELEVATIONS ARE MEASURED FROM TOPOF BASE PLATE TO MATCH STRUCTURALANALYSIS. ELEVATIONS DO NOT REFLECT TRUEABOVE GROUND LEVEL (A.G.L.)

5. TOWER ELEVATION DEPICTION MAY NOT REFLECTALL EQUIPMENT INCLUDED IN STRUCTURALANALYSIS. REFER TO STRUCTURAL ANALYSIS FORFULL TOWER LOADING.

PER MOUNT ANALYSIS COMPLETED BYAMERICAN TOWER CORP., DATED APRIL 27, 2022,THE EXISTING MOUNT MUST BE MODIFIED TOADEQUATELY SUPPORT THE PROPOSEDLOADING. THE MOUNT MODIFICATION DETAILEDAT THE END OF THIS PLAN SET, MUST BEINSTALLED PRIOR TO THE INSTALLATION OF THEPROPOSED ANTENNAS AND OTHER EQUIPMENT.

2C-401

PROPOSED T-MOBILEEQUIPMENT & MOUNT

MODIFICATIONS

1C-401

PROPOSED T-MOBILERAD CENTER @ 117'

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

C-401

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

ANTENNA INFORMATION& SCHEDULE

0 FOR CONSTRUCTION ADE 06/02/22

0

1 EXISTING ANTENNA PLANSCALE: N.T.S. 2 FINAL ANTENNA PLAN

SCALE: N.T.S.

3 EQUIPMENT SCHEDULES

FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY

MODEL NUMBER STATUS COAX HYBRID STATUS

(2) 6X24 (1.99") ADD

EXISTING FIBER DISTRIBUTION/OVP BOX EXISTING CABLING SUMMARY

MODEL NUMBER STATUS COAX HYBRID STATUS

(12) 1-5/8" RMV

CABLE LENGTHS FOR JUMPERS

JUNCTION BOX TO RRU: 15'RRU TO ANTENNA: 10'

1. CONFIRM WITH T-MOBILE REPFOR APPLICABLEUPDATES/REVISIONS ANDMOST RECENT RFDS FOR NSNCONFIGURATION (CONFIG). GCTO CAP ALL UNUSED PORTS.

2. CONFIRM SPACING OFPROPOSED EQUIP DOES NOTCAUSE TOWER CONFLICTSNOR IMPEDE TOWER CLIMBINGPEGS.

NOTES

STATUS ABBREVIATIONS

RMV: TO BE REMOVED: TO REMAIN

REL: TO BE RELOCATEDADD: TO BE ADDED

FINAL ANTENNA SCHEDULELOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY

SECTOR RAD AZ POS ANTENNA BAND MECH/ELECD-TILT STATUS ADDITIONAL TOWER

MOUNTED EQUIPMENT STATUS

ALPHA 117' 60°

A1 AIR 6419 B41 L2500/N2500 0°/2°,2° ADDA2 VV-65A-R1 L2100/L1900/G1900 0°/2°,2° ADD 4460 B25+B66 ADDA3

A4

BETA 117' 180°

B1 AIR 6419 B41 L2500/N2500 0°/2°,2° ADDB2 VV-65A-R1 L2100/L1900/G1900 0°/2°,2° ADD 4460 B25+B66 ADDB3

B4

GAMMA 117' 300°

C1 AIR 6419 B41 L2500/N2500 0°/2°,2° ADDC2 VV-65A-R1 L2100/L1900/G1900 0°/2°,2° ADD 4460 B25+B66 ADDC3

C4

EXISTING ANTENNA SCHEDULELOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY

SECTOR RAD AZ POS ANTENNA BAND MECH/ELECD-TILT STATUS ADDITIONAL TOWER

MOUNTED EQUIPMENT STATUS

APXV18-206517S-C-A20 L1900/G1900 0°/2° RMV KRY 112 489/2 RMV

4415 B66KRY 112 144/2

RMVRMV

APXV18-206517S-C-A20 L1900/G1900 0°/2° RMV KRY 112 489/2 RMV

4415 B66KRY 112 144

2

RMVRMV

APXV18-206517S-C-A20 L1900/G1900 0°/2° RMV KRY 112 489/2 RMV

4415 B66KRY 112 144

2

RMVRMV

PER MOUNT ANALYSIS COMPLETED BYAMERICAN TOWER CORP., DATED APRIL 27, 2022,THE EXISTING MOUNT MUST BE MODIFIED TOADEQUATELY SUPPORT THE PROPOSEDLOADING. THE MOUNT MODIFICATION DETAILEDAT THE END OF THIS PLAN SET, MUST BEINSTALLED PRIOR TO THE INSTALLATION OF THEPROPOSED ANTENNAS AND OTHER EQUIPMENT.

(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)

(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)

(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)

(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)

PROPOSED AIR 6419 B41 ANTENNA(1 PER SECTOR) (TYP. 3)

PROPOSED 4460 B25+B66 RRU(1 PER SECTOR) (TYP. 3)

PROPOSED VV-65A-R1 ANTENNA(1 PER SECTOR) (TYP. 3)

A1

A2

A4

B1B2B4

C1

C2

C4

AZ.=

ALPHA60°

AZ.= BE

TA180°

AZ.=GAMMA

300°

PROPOSED MOUNT MODIFICATIONS(REFER TO SHEETS AT THE END OFTHIS PLAN SET)

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

C-501

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

CONSTRUCTIONDETAILS

0 FOR CONSTRUCTION ADE 06/02/22

0

3 PROPOSED RRU MOUNTING DETAIL - TYPICALSCALE: N.T.S.

TO BE REPLACED WITH PROPOSED 2-3/8" O.D. X 96" LONGIF REQUIRED TO ACCOMMODATE PROPOSED MOUNTING BRACKET

1 PROPOSED ANTENNA MOUNTING DETAIL - TYPICALSCALE: N.T.S.

PROPOSED 2-3/8" O.D. X 96" LONG

PROPOSED ANTENNA

2 PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICALSCALE: N.T.S.

PROPOSED RRU MOUNT LOCATION (OPTION 2)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)

PROPOSED RRU MOUNT LOCATION (OPTION 1)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)

PROPOSED RRU MOUNT LOCATION (OPTION 3)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

E-501

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

GROUNDING DETAILS

0 FOR CONSTRUCTION ADE 06/02/22

0

NOTES:

1. THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHTADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THECONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THECONSTRUCTION MANAGER OF ANY CONFLICTS.

2. SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATESTEDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHENNATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN.

PROPOSED CONNECTOR ANDWEATHERPROOFING KIT

1 TYPICAL ANTENNA GROUNDING DIAGRAMSCALE: N.T.S.

PROPOSED ANTENNA

PROPOSED JUMPER

PROPOSED WEATHERPROOFING KIT

2E-501

3E-501

GROUND BAR MOUNTEDNEAR/BELOW ANTENNA(TO BE INSTALLED IFREQUIRED)

#6 AWG STRANDED CUWIRE WITH GREEN, 600V,THWN INSULATION

ANTENNA CABLE TOCABINET (TYP.)

PROPOSED CABLEGROUND KIT

PROPOSED #6 AWGSTRANDED CU

WIRE WITH GREEN, 600V,THWN INSULATION

TO PROPOSED RRUGROUND LUG (TYP.)

DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECTGROUND WIRE DOWN TO GROUND BAR.CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PARTNUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS.

2 CABLE GROUND KIT CONNECTION DETAILSCALE: N.T.S.

TO ANTENNA

TO EQUIPMENT

TO GROUND BAR

ANTENNA CABLE 2 1/2"Ø MAX

GROUNDING KIT PER CABLEMANUFACTURER'S RECOMMENDATIONS(ANDREW OR APPROVED EQUAL)

#6 AWG STRANDED COPPER GROUNDWIRE (GROUNDED TO GROUND BAR)

GROUND KIT NOTES:1.

2.

1/4" X 4" X 6" GROUND BAR(ERICO P/N: EGBA14406CC OR EQUAL)

3 TOWER GROUND BAR DETAILSCALE: N.T.S.

GROUND BAR NOTES:

1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS,WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S).

2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER.

3/8" SS LOCK WASHER(EACH SIDE)

TWO-HOLE LUG, TO BE USEDWITH #2 AWG BCW(LOWER TOWER GROUNDBAR ONLY)

3/8" X 1-1/2" SS BOLT(EACH SIDE)

OCPD SIZE WIRE SIZE GROUND SIZE CONDUIT SIZE

80A/2P 2#3 AWG #8 AWG 1-1/4"

100/2P 2#2 AWG #8 AWG 1-1/4"

125A/2P 2#1 AWG #8 AWG 1-1/2"

150A/2P 2#1/0 AWG #8 AWG 1-1/2"

ELECTRICAL NOTES:

1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATEWITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITYCOMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS,BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENTREQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORKSHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OFTHE STATE AND NATIONAL CODES, ORDINANCES ANDREGULATIONS APPLICABLE TO THIS PROJECT.

2. ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUNDEQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASEDON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE.CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HASSUFFICIENT SPACE FOR PROPOSED BREAKER. PROPOSED CABLEAND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART.

3. FOR SPECIFIC CABINET / ANCILLARY EQUIPMENT WIRINGREQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULDREFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FORTHIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITHLOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS &PRACTICES.

4 CABINET GROUNDING DETAILSCALE: N.T.S.

PROPOSED CABINET

#2 AWG STRANDED GREENINSULATED COPPER CONDUCTOR

06/03/2022

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

R-601

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

SUPPLEMENTAL2 ANTENNA CONFIGURATION

SCALE: NOT TO SCALE

NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDEDBY REQUEST OF CUSTOMER WITHOUT EDIT.

1 CABINET CONFIGURATIONSCALE: NOT TO SCALE

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

R-602

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

SUPPLEMENTAL

1 EQUIPMENT DETAILSSCALE: NOT TO SCALE

A

B

C

FRONT VIEW

TOP VIEW

SIDE VIEW

C

ERICSSON

FRONT VIEWSIDW VIEW

A

C B

TOP VIEW

RRU SPECIFICATIONS

RRU MODEL A B CWEIGHT

(LBS)

RADIO 4460 B25+B66 19.6" 15.7" 12.1" 109.0

ANTENNA SPECIFICATIONS

ANTENNA MODEL A B CWEIGHT

(LBS)

AIR6449 B41 33.1" 20.6" 8.6" 104.0

VV-65A-R1 54.7" 12.1" 4.6" 23.8

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

R-603

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

SUPPLEMENTAL

NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.

·

·

2.5" KNOCKOUTS w/ RIGID CONDUIT, LB CONDUIT BODYFOR ALARM CABLE & TEMP SENSOR ROUTING. CONDUITMUST BE PROPERLY SECURED TO PREVENT DAMAGE

2.5" KNOCKOUTS w/ RIGID CONDUIT, LB CONDUITBODY FOR BATTERY CABLE CONDUIT MUST BEPROPERLY SECURED TO PREVENT DAMAGE

2.5" KNOCKOUTS w/ RIGID CONDUIT, LB CONDUIT BODYFOR AAV FIBER OPTIC CABLE w/NID POWER. CONDUITMUST BE PROPERLY SECURED TO PREVENT DAMAGE

2.5" KNOCKOUTS w/ RIGID CONDUIT, LBCONDUIT BODY FOR MICROWAVE. CONDUITMUST BE PROPERLY SECURED TO PREVENTDAMAGE

2.5" KNOCKOUTS LOWER REARINTENDED FOR HYBRID/MLE CABLES

CABINET GROUND POINTS

2.5" KNOCKOUT w/ RIGID CONDUIT, LBCONDUIT BODY FOR AC POWER. CONDUITMUST BE PROPERLY SECURED TO PREVENTDAMAGE

2.5" KNOCKOUT UNUSED FORDEDICATED CIRCUIT TO SERVICEOUTLET

2.5" KNOCKOUTS w/ RIGID CONDUIT, LRCONDUIT BODY WILL BE USED FORINTER-BASEBAND CONNECTION RUNNINGCONDUIT TO LEGACY 6131,6201, ODE ORMUAC CABINETS FOR I. CONDUIT MUST BEPROPERLY SECURED TO PREVENT DAMAGE

CABINET LOWER 4" PLINTH CAN BEREMOVED FOR ADDITIONAL 12" PLINTH

CABINET GROUND POINT

63"

4"

33.6"

8" 25.6"

CABINET GROUND POINT5/8" PLUG TO BE PUNCHED TO 1.5" FORGPS/GNSS w/ 1" RIGID CONDUIT & LLCONDUIT BODY

4" R

EAR

CLE

ARAN

CE

25.6"

25.6

"

DOORCLOSED

25" D

OO

R O

PEN

25.6"

25.6

"

2.5"

17"

5"

22.5"

27"

(OPTIONAL) 2.5" DC POWERKNOCKOUT TO B160

(OPTIONAL) 2.5" KNOCKOUT w/ LB CONDUITBODY FOR ALARM & TEMP SENSOR ROUTINGTO B160

“”

(ALTERNATE) 1" CONDUIT w/ PULLING ELBOW TO PPC.(GENERATOR, PPC, ATS & TOWER ALARMS)

1" LB CONDUIT BODY TO 1" CONDUIT TO PPC.(GENERATOR, PPC, ATS & TOWER ALARMS)

2.5" KNOCKOUT UNUSED FORDEDICATED CIRCUIT TO SERVICEOUTLET

1 ERICSSON 6160 SITE SUPPORT CABINET SPECIFICATIONSSCALE: N.T.S.

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

R-604

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

SUPPLEMENTAL

DC POWER CABLES(SHOWN IN RED)

GROUND CABLES(SHOWN IN GREEN)

INTERNAL GROUND BAR

FIBER CABLES (SHOWN INYELLOW)

ETHERNET CABLES(SHOWN IN BLUE)

RECTIFIERS

CABLE CHASE

1U DCDU

BACKHAUL ROUTER

BASEBAND

EXPANSION SPACE (BB,MW, & VB)

VOLTAGE BOOSTER

SPACE INTENTIONALLY LEFTBLANK TO BE ABLE TO WORK ONINTERNAL CABLING & FOR SPD'SON THE BOTTOM

ACCESS SLOTS

DC DISTRIBUTION

20-60VDC15A

DCINPUT +12V

DCPSU250W

20-60VDC15A

DCINPUT +12V

DCPSU250W

PS1 PS2 NOKIA7250 IXR-E

24SFP +8SFP28

2QSFP28

ResetSD

Card PS2PS1 Stat Fan LOC USB MgmtConsole

1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18 19 2120 2322 24 25 26 27 28 3029 31 32 33 34

1PPS

20-60VDC15A

DCINPUT +12V

DCPSU250W

20-60VDC15A

DCINPUT +12V

DCPSU250W

PS1 PS2 NOKIA7250 IXR-E

24SFP +8SFP28

2QSFP28

ResetSD

Card PS2PS1 Stat Fan LOC USB MgmtConsole

1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18 19 2120 2322 24 25 26 27 28 3029 31 32 33 34

1PPS

NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.

1 ERICSSON 6160 CABINET DETAILSSCALE: N.T.S.

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

R-605

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

SUPPLEMENTAL

RETURN BUS BAR

-48V BUS

DC DISTRIBUTIONBREAKERS (21)

ALRM BOARD IB2

ALRM BOARD EIBRECTIFIERS (1-9)

POWER CONTROLLER

DC DISTRIBUTION UNIT

MAIN LOAD CONNECTORSMAIN LOAD CONNECTORS

PRIORITY LOAD CONNECTORS

LLVD2 #1-6CB SLOT #7-12LLVD1 #1-6CB SLOT #1-6

BLVD #1-6CB SLOT #13-21

NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.

1 ERICSSON 6160 ELECTRICAL DETAILSSCALE: N.T.S.

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

R-606

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

SUPPLEMENTAL

NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDEDAT THE REQUEST OF THE CUSTOMER WITHOUT EDIT.

1 ERICSSON B160 BATTERY CABINET SPECIFICATIONSSCALE: N.T.S.

2.5" KNOCKOUTS w/ RIGID CONDUIT, LBCONDUIT BODY FOR ALARM CABLE & TEMPSENSOR ROUTING. CONDUIT MUST BEPROPERLY SECURED TO PREVENT DAMAGE

2.5" KNOCKOUTS w/ RIGID CONDUIT, LBCONDUIT BODY FOR BATTERY CABLE CONDUITMUST BE PROPERLY SECURED TO PREVENTDAMAGE

CABINET GROUND POINTS

(OPTIONAL) 2.5" DC POWERKNOCKOUTS TO 6160

(OPTIONAL) 2.5" KNOCKOUTS FOR ALARM &TEMP SENSOR ROUTING TO 6160

CABINET GROUND POINT

63"

29.5"

27.5"2"

CABINET GROUND POINT

4" R

EAR

CLE

ARAN

CE

2'-1 5/8"

27.5

"26

.5"

25A AUX BREAKERS, FANS,LIGHTS, ETC.

ALARM BOX, PRELABLED

3X BATTERY SHELVES, UP TO200A HR, w/ PREINSTALLEDHEATERS

BATTERY RACK

BATTERY RACK

BATTERY RACK

BATTERY VIBRATIONMOUNTS

·

·

“”

3 x 300A BREAKERS

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

SHEET NUMBER: REVISION:

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

R-607

SEAL:

DESCRIPTIONREV. DATEBY

ATC TOWER SERVICES, LLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: 7442

THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FOR

WHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATES

TO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECT

NOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.

CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIED

CARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BY

THE LATEST VERSION.

DATE DRAWN: 06/02/22

ATC JOB NO:

CT508//VERIZON CHAPLINCUSTOMER ID:

14071468

CT11508FCUSTOMER #:

T Mobile ©

411216

ATC SITE NAME:CT CHAPLIN SOUTH CT

CT508//VERIZON CHAPLIN

123 PALMER ROADCHAPLIN, CT 06235-2416

ATC SITE NUMBER:

SITE ADDRESS:

T-MOBILE SITE NAME:

11490 BLUEGRASS PKWYLOUISVILLE, KY 40299

502-437-5252

DOPPOWEROF DESIGN

SRETTAP.E

KM

CITCENOCFOE

TS

L I C E N S E D

PROFES I NA ENGINR

ATN

UT

AR ON

S O L

EE

No. 31284

0 FOR CONSTRUCTION ADE 06/02/22

0

SUPPLEMENTAL

1 MOUNT ANALYSIS

NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMERWITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNTANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THECONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TOVERIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONSTRUCTION.

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

<<w=175; h=175; n=BLANK - SIG; a=11>>

PROJECT LOCATIONGEOGRAPHIC COORDINATES

LATITUDE: 41.784528

LONGITUDE: -72.135694

PROJECT TEAM

TOWER OWNERAMERICAN TOWER

10 PRESIDENTAL WAY

WOBURN, MA 01801

ENGINEERED BYATC TOWER SERVICES

3500 REGENCY PARKWAY, SUITE 100

CARY, NC 27518

CARRIER INFORMATIONCARRIER: T-MOBILE

CARRIER SITE NAME: CT508//VERIZON CHAPLIN

CARRIER SITE NUMBER: CT11508F

SHEET SHEET TITLE REV.G-002 IBC GENERAL NOTES & MOUNT MODIFICATION INSPECTION 0S-101 MODIFICATION PROFILE 0R-901 SUPPLEMENTAL 0R-902 SUPPLEMENTAL 0R-903 SUPPLEMENTAL 0R-904 SUPPLEMENTAL 0

PROJECT DESCRIPTIONTHE PROJECT DEPICTED IN THESE PLANS ARE BASED ON THERECOMMENDATIONS OUTLINED IN THE STRUCTURAL ANALYSIS COMPLETEDUNDER ENGINEERING PROJECT NUMBER 14071468_C8_01 DATED 04/04/22.SATISFACTORY COMPLETION OF THE WORK INDICATED IN THESE PLANS WILLRESULT IN THE STRUCTURE MEETING THE REQUIREMENTS OF THESPECIFICATIONS UNDER WHICH THE STRUCTURAL WAS COMPLETED.

PROJECT NOTETHE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLEFACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C.§ 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THATINVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OFTRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDERCFR § 1.6100 (B)(7).

COMPLIANCE CODEALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED INACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES ASADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESEPLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESECODES.

1. ANSI/TIA/EIA: STRUCTURAL STANDARDS (222-H EDITION)

2. INTERNATIONAL BUILDING CODE (2018 IBC)

3. CONNECTICUT STATE BUILDING CODE (2018)

SITE NAME:SITE NUMBER:

ATC PROJECT NUMBER:SITE ADDRESS:

CT CHAPLIN SOUTH CT41121614071468_C9_04123 PALMER RDCHAPLIN, CT 06235

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.

DESCRIPTIONREV. DATEBY

ATC SITE NUMBER:

ATC SITE NAME:

SITE ADDRESS:

ATC JOB NO:

DRAWN BY:

APPROVED BY:

DATE DRAWN:

SHEET NUMBER: REVISION:

411216

CT CHAPLIN SOUTH CT

CONNECTICUT

123 PALMER RDCHAPLIN, CT 06235

KJ

MCC

04/29/2214071468_C9_04

G-001

A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: PEC.0001553

COVER

0 FIRST ISSUE KJ 04/29/22

0

VICINITY MAP LOCATION MAP

PALMER RD

SITE LOCATION

PLEASE CONTACT [email protected] ORAMERICAN TOWER NOC AT 877-518-6937 FOR ASSISTANCE

BIRD WATCH SITE:MOUNT REINFORCEMENT DRAWINGS

PREPARED FOR T-MOBILE

RIDGE RD

PHO

ENIX

VILL

E RD

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

AutoCAD SHX Text
Know what's
AutoCAD SHX Text
below.
AutoCAD SHX Text
Call
AutoCAD SHX Text
before you dig.
AutoCAD SHX Text
R

<<w=175; h=175; n=BLANK - SIG; a=11>>

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.

DESCRIPTIONREV. DATEBY

ATC SITE NUMBER:

ATC SITE NAME:

SITE ADDRESS:

ATC JOB NO:

DRAWN BY:

APPROVED BY:

DATE DRAWN:

SHEET NUMBER: REVISION:

411216

CT CHAPLIN SOUTH CT

CONNECTICUT

123 PALMER RDCHAPLIN, CT 06235

KJ

MCC

04/29/2214071468_C9_04

G-002

A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: PEC.0001553

IBC GENERAL NOTES &MOUNT MODIFICATION

INSPECTION

0 FIRST ISSUE KJ 04/29/22

0

MAXIMUM ALLOWABLE ANGLE CLIP

1.5 X LMAX.

L

AREA OF ANGLETO BE CLIPPED

GENERAL1. ALL WORK TO BE COMPLETED PER APPLICABLE LOCAL, STATE, FEDERAL CODES AND

ORDINANCES AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS FOR WIRELESSTOWER SITES. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND ABIDING BYALL REQUIRED PERMITS.

2. ALL WORK INDICATED ON THESE DRAWINGS SHALL BE PERFORMED BY QUALIFIEDCONTRACTORS EXPERIENCED IN TOWER AND FOUNDATION CONSTRUCTION.

3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY OF ANYINSTALLATION INTERFERENCES. ALL NEW WORK SHALL ACCOMMODATE EXISTINGCONDITIONS. DETAILS NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL FOLLOWSIMILAR DETAILS FOR THIS JOB.

4. ANY SUBSTITUTIONS SHALL CONFORM TO THE REQUIREMENTS OF THESE NOTES ANDSPECIFICATIONS, AND SHOULD BE SIMILAR TO THOSE SHOWN. ALL SUBSTITUTIONSSHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVALPRIOR TO FABRICATION.

5. ANY MANUFACTURED DESIGN ELEMENTS SHALL CONFORM TO THE REQUIREMENTS OFTHESE NOTES AND SPECIFICATIONS AND SHOULD BE SIMILAR TO THOSE SHOWN.THESE DESIGN ELEMENTS MUST BE STAMPED BY AN ENGINEER PROFESSIONALLYREGISTERED IN THE STATE OF THE PROJECT, AND SUBMITTED TO THE ENGINEER OFRECORD FOR APPROVAL PRIOR TO FABRICATION.

6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL CODES AND OSHA SAFETYREGULATIONS.

7. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALLMISCELLANEOUS SHORING, BRACING, TEMPORARY SUPPORTS, ETC. NECESSARY, PERANSI/TIA-322 AND ANSI/ASSE A10.48, TO PROVIDE A COMPLETE AND STABLESTRUCTURE AS SHOWN ON THESE DRAWINGS.

8. CONTRACTOR'S PROPOSED INSTALLATION SHALL NOT INTERFERE, NOR DENY ACCESSTO, ANY EXISTING OPERATIONAL AND SAFETY EQUIPMENT.

STRUCTURAL STEEL1. ALL DETAILING, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM

TO THE AISC SPECIFICATIONS, LATEST EDITION.

2. ALL EXPOSED STRUCTURAL STEEL MEMBERS SHALL BE HOT-DIPPED GALVANIZEDAFTER FABRICATION PER ASTM A123. EXPOSED STEEL HARDWARE AND ANCHORBOLTS SHALL BE GALVANIZED PER ASTM A153 OR B695.

3. ALL U-BOLTS SHALL BE ASTM A36 OR EQUIVALENT, WITH LOCKING DEVICE, UNLESSNOTED OTHERWISE.

4. FIELD CUT EDGES, EXCEPT DRILLED HOLES, SHALL BE GROUND SMOOTH.

5. ALL FIELD CUT SURFACES, FIELD DRILLED HOLES & GROUND SURFACES WHEREEXISTING PAINT OR GALVANIZATION REMOVAL WAS REQUIRED SHALL BE REPAIREDWITH (2) BRUSHED COATS OF ZRC GALVILITE COLD GALVANIZING COMPOUND PERASTM A780 AND MANUFACTURERS RECOMMENDATIONS.

6. ALL STRUCTURAL STEEL EMBEDDED IN THE CONCRETE SHALL BE APPLIED WITH (2)BRUSHED COATS OF POLYGUARD CA-14 MASTIC OR EQUIVALENT. REFER TO THEMANUFACTURER SPECIFICATIONS FOR SURFACE PREPARATION AND APPLICATION.APPLICATION OF POLYGUARD 400 WRAP IS NOT ESSENTIAL.

7. CONTRACTOR SHALL PERFORM WORK ON ONLY ONE (1) TOWER FACE ANDREPLACE/REINFORCE ONE (1) BOLT/MEMBER AT A TIME.

8. ALL FIELD DRILLED HOLES TO BE USED FOR FIELD BOLTING INSTALLATION SHALL BESTANDARD HOLES, AS DEFINED BY AISC, UNLESS NOTED OTHERWISE.

PAINT1. AS REQUIRED, CLEAN AND PAINT PROPOSED STEEL ACCORDING TO FAA ADVISORY

CIRCULAR AC 70/7460-1L.

WELDING1. ALL WELDING TO BE PERFORMED BY AWS CERTIFIED WELDERS AND CONDUCTED IN ACCORDANCE

WITH THE LATEST EDITION OF THE AWS WELDING CODE D1.1.

2. ALL WELDS SHALL BE INSPECTED VISUALLY. IF DIRECTED BY ENGINEER OF RECORD, 25% OF WELDSSHALL BE INSPECTED WITH DYE PENETRANT OR MAGNETIC PARTICLE (100% IF REJECTABLE DEFECTSARE FOUND) TO MEET THE ACCEPTANCE CRITERIA OF AWS D1.1. REPAIR ALL WELDS AS NECESSARY.

3. INSPECTION SHALL BE PERFORMED BY AN AWS CERTIFIED WELD INSPECTOR.

4. ALL ELECTRODES TO BE LOW HYDROGEN, MATCHING FILLER AND/OR BASE METAL, PER AWS D1.1,UNLESS NOTED OTHERWISE.

5. IN CASES WHERE BASE METAL GRADE IS UNKNOWN, ALL WELDING ON LATTICE TOWERS SHALL BEDONE WITH E70XX ELECTRODES; ALL WELDING ON POLE STRUCTURES SHALL BE DONE WITH E80XXELECTRODES, UNLESS NOTED OTHERWISE.

6. PRIOR TO FIELD WELDING GALVANIZED MATERIAL, CONTRACTOR SHALL GRIND OFF GALVANIZING 1/2"BEYOND ALL FIELD WELD SURFACES. AFTER WELD AND WELD INSPECTION IS COMPLETE, REPAIR ALLGROUND AND WELDED SURFACES WITH ZRC GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780AND MANUFACTURERS RECOMMENDATIONS.

BOLT TIGHTENING PROCEDURE1. STRUCTURAL CONNECTIONS TO BE ASSEMBLED AND INSPECTED IN ACCORDANCE WITH RCSC

SPECIFICATIONS.

2. FLANGE BOLTS SHALL BE INSTALLED AND TIGHTENED USING DIRECT TENSION INDICATING (DTI)SQUIRTER WASHERS. DTI SQUIRTER WASHERS ARE TO BE INSTALLED AND ORIENTED / TIGHTENED PERMANUFACTURER SPECIFICATIONS TO ACHIEVE DESIRED LEVEL OF BOLT PRE-TENSION.

3. IN LIEU OF USING DTI SQUIRTER WASHERS, FLANGE BOLTS MAY BE TIGHTENED USING AISC / RCSC"TURN-OF-THE-NUT" METHOD, PENDING APPROVAL BY THE ENGINEER OF RECORD (EOR). TIGHTENFLANGE BOLTS USING THE CHART BELOW:

BOLT LENGTHS UP TO AND INCLUDING FOUR DIAMETERS1/2" BOLTS UP TO AND INCLUDING 2.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT5/8" BOLTS UP TO AND INCLUDING 2.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT3/4" BOLTS UP TO AND INCLUDING 3.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT7/8" BOLTS UP TO AND INCLUDING 3.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1" BOLTS UP TO AND INCLUDING 4.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-1/8" BOLTS UP TO AND INCLUDING 4.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-1/4" BOLTS UP TO AND INCLUDING 5.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-3/8" BOLTS UP TO AND INCLUDING 5.5 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT1-1/2" BOLTS UP TO AND INCLUDING 6.0 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT

BOLT LENGTHS OVER FOUR DIAMETERS BUT NOT EXCEEDING EIGHT DIAMETERS1/2" BOLTS 2.25 TO 4.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT5/8" BOLTS 2.75 TO 5.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT3/4" BOLTS 3.25 TO 6.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT7/8" BOLTS 3.75 TO 7.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1" BOLTS 4.25 TO 8.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-1/8" BOLTS 4.75 TO 9.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-1/4" BOLTS 5.25 TO 10.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-3/8" BOLTS 5.75 TO 11.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT1-1/2" BOLTS 6.25 TO 12.0 INCH LENGTH +1/2 TURN BEYOND SNUG TIGHT

BOLT TIGHTENING PROCEDURE (CONTINUED)4. SPLICE BOLTS SUBJECT TO DIRECT TENSION SHALL BE INSTALLED AND TIGHTENED AS PER

SECTION 8.2.1 OF THE AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490BOLTS", LOCATED IN THE AISC MANUAL OF STEEL CONSTRUCTION. THE INSTALLATIONPROCEDURE IS PARAPHRASED AS FOLLOWS:

FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES AND TIGHTENED BY ONEOF THE METHODS DESCRIBED IN SUBSECTION 8.2.1 THROUGH 8.2.4.

8.2.1 TURN-OF-NUT PRETENSIONINGBOLTS SHALL BE INSTALLED IN ALL HOLES OF THE CONNECTION AND BROUGHT TO ASNUG TIGHT CONDITION AS DEFINED IN SECTION 8.1, UNTIL ALL THE BOLTS ARESIMULTANEOUSLY SNUG TIGHT AND THE CONNECTION IS FULLY COMPACTED.FOLLOWING THIS INITIAL OPERATION ALL BOLTS IN THE CONNECTION SHALL BETIGHTENED FURTHER BY THE APPLICABLE AMOUNT OF ROTATION SPECIFIED ABOVE.DURING THE TIGHTENING OPERATION THERE SHALL BE NO ROTATION OF THE PART NOTTURNED BY THE WRENCH. TIGHTENING SHALL PROGRESS SYSTEMATICALLY.

5. ALL OTHER BOLTED CONNECTIONS SHALL BE BROUGHT TO A SNUG TIGHT CONDITION AS DEFINEDIN SECTION 8.1 OF THE SPECIFICATION.

ALL BOLT HOLES SHALL BE ALIGNED TO PERMIT INSERTION OF THE BOLTS WITHOUTUNDUE DAMAGE TO THE THREADS. BOLTS SHALL BE PLACED IN ALL HOLES WITHWASHERS POSITIONED AS REQUIRED AND NUTS THREADED TO COMPLETE THEASSEMBLY. COMPACTING THE JOINT TO THE SNUG-TIGHT CONDITION SHALL PROGRESSSYSTEMATICALLY FROM THE MOST RIGID PART OF THE JOINT. THE SNUG-TIGHTENEDCONDITION IS THE TIGHTNESS THAT IS ATTAINED WITH A FEW IMPACTS OF AN IMPACTWRENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCHTO BRING THE CONNECTED PLIES INTO FIRM CONTACT.

MODIFICATION INSPECTION NOTESTHE MOUNT MODIFICATION INSPECTION (MMI) PROCEDURE IS INTENDED TO CONFIRM THAT CONSTRUCTION ANDINSTALLATION MEETS ENGINEERING DESIGN, ATC PROCEDURES AND ATC STANDARD SPECIFICATIONS FORWIRELESS TOWER SITES.

TO ENSURE THAT THE REQUIREMENTS OF THE MMI ARE MET, IT IS VITAL THAT THE GENERAL CONTRACTOR SUBMITALL REQUIRED PHOTOGRAPHS AND DRAWINGS TO AMERICAN TOWER CORPORATION (ATC).

GENERAL CONTRACTORTHE GENERAL CONTRACTOR IS REQUIRED TO:

· REVIEW THE REQUIREMENTS OF THE MMI CHECKLIST.

· UNDERSTAND ALL INSPECTION REQUIREMENTS.

THE GENERAL CONTRACTOR SHALL PERFORM AND RECORD THE INSPECTION RESULTS INACCORDANCE WITH THE REQUIREMENTS OF THE MMI CHECKLIST.

MOUNT MODIFICATION INSPECTION CHECKLIST

INSPECTION DOCUMENT DESCRIPTION INSPECTION TESTINGREQUIRED RESPONSIBILITY

ON-SITE COLD GALVANIZING VERIFICATION PHOTOGRAPHIC EVIDENCE OF COLD GALVANIZATION TYPE AND APPLICATION IN ALL APPLICABLE LOCATIONS TO BE INCLUDED WITHIN THE MMIREPORT GC

GC AS-BUILT DRAWINGS WITHCONSTRUCTION RED-LINES

"AS-BUILT" DRAWINGS INDICATING ANY APPROVED CHANGES TO ENGINEERED PLANS TO MMI FOR APPROVAL/REVIEW ANDINCLUSION IN MMI REPORT GC

PHOTOGRAPHSPHOTOGRAPHIC EVIDENCE OF MOUNT MODIFICATION INSPECTION, ON SITE REMEDIATION, AND ITEMS FAILING INSPECTION &REQUIRING FOLLOW UP TO BE INCLUDED WITHIN THE MMI REPORT. COMPLETE PHOTO LOG IS TO BE SUBMITTED WITHIN MMIREPORT.

GC

TABLE KEY:MMI - MOUNT MODIFICATION INSPECTIONGC - GENERAL CONTRACTORATC - AMERICAN TOWER CORPORATION

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

<<w=175; h=175; n=BLANK - SIG; a=11>>

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.

DESCRIPTIONREV. DATEBY

ATC SITE NUMBER:

ATC SITE NAME:

SITE ADDRESS:

ATC JOB NO:

DRAWN BY:

APPROVED BY:

DATE DRAWN:

SHEET NUMBER: REVISION:

411216

CT CHAPLIN SOUTH CT

CONNECTICUT

123 PALMER RDCHAPLIN, CT 06235

KJ

MCC

04/29/2214071468_C9_04

S-101

A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: PEC.0001553

MODIFICATION PROFILE

0 FIRST ISSUE KJ 04/29/22

0

NOTES:1. CONTRACTOR TO INSTALL MOUNT MODIFICATIONS PER THE MANUFACTURERS SPECIFICATION.

MODIFICATIONS SHALL NOT OBSTRUCT, INTERFERE, OR BLOCK EXISTING SAFETY CLIMB SYSTEM.IF ANY OF THESE OCCURS DURING INSTALLATION CONTACT THE AMERICAN TOWER PMI [email protected]

2. IN THE EVENT A PROPOSED MODIFICATION PART LISTED IN THE DRAWINGS IS NOT AVAILABLE, ANAPPROVED EQUIVALENT CAN BE SUBSTITUTED. FOR APPROVAL OF EQUIVALENT PART ORQUESTIONS PLEASE CONTACT AMERICAN TOWER PMI INBOX AT [email protected].

SAFETY CLIMB LOCATION

MOUNT MODIFICATIONFRONT VIEW

MOUNT MODIFICATIONISOMETRIC VIEW

MOUNT MODIFICATIONTOP VIEW

PROPOSEDSITE PRO 1 HANDRAIL REINFORCEMENT KIT

[PRK-SFS]

7'-3"2'

-0"

PROPOSEDSITE PRO 1 HANDRAIL REINFORCEMENT KIT

[PRK-SFS]

PROPOSEDSITE PRO 1 HANDRAIL REINFORCEMENT KIT

[PRK-SFS]

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

AutoCAD SHX Text
EXISTING PLATFORM
AutoCAD SHX Text
CLIMBING PEGS WITH SAFETY CABLE
AutoCAD SHX Text
EXISTING TOWER
AutoCAD SHX Text
EXISTING PLATFORM
AutoCAD SHX Text
EXISTING PLATFORM
AutoCAD SHX Text
EXISTING PLATFORM

<<w=175; h=175; n=BLANK - SIG; a=11>>

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.

DESCRIPTIONREV. DATEBY

ATC SITE NUMBER:

ATC SITE NAME:

SITE ADDRESS:

ATC JOB NO:

DRAWN BY:

APPROVED BY:

DATE DRAWN:

SHEET NUMBER: REVISION:

411216

CT CHAPLIN SOUTH CT

CONNECTICUT

123 PALMER RDCHAPLIN, CT 06235

KJ

MCC

04/29/2214071468_C9_04

R-901

A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: PEC.0001553

SUPPLEMENTAL

0 FIRST ISSUE KJ 04/29/22

0

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

<<w=175; h=175; n=BLANK - SIG; a=11>>

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.

DESCRIPTIONREV. DATEBY

ATC SITE NUMBER:

ATC SITE NAME:

SITE ADDRESS:

ATC JOB NO:

DRAWN BY:

APPROVED BY:

DATE DRAWN:

SHEET NUMBER: REVISION:

411216

CT CHAPLIN SOUTH CT

CONNECTICUT

123 PALMER RDCHAPLIN, CT 06235

KJ

MCC

04/29/2214071468_C9_04

R-902

A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: PEC.0001553

SUPPLEMENTAL

0 FIRST ISSUE KJ 04/29/22

0

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

<<w=175; h=175; n=BLANK - SIG; a=11>>

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.

DESCRIPTIONREV. DATEBY

ATC SITE NUMBER:

ATC SITE NAME:

SITE ADDRESS:

ATC JOB NO:

DRAWN BY:

APPROVED BY:

DATE DRAWN:

SHEET NUMBER: REVISION:

411216

CT CHAPLIN SOUTH CT

CONNECTICUT

123 PALMER RDCHAPLIN, CT 06235

KJ

MCC

04/29/2214071468_C9_04

R-903

A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: PEC.0001553

SUPPLEMENTAL

0 FIRST ISSUE KJ 04/29/22

0

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

<<w=175; h=175; n=BLANK - SIG; a=11>>

Cop

yrig

ht ©

20

22 A

TC IP

LLC

, All

Rig

hts

Res

erve

d.

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONAS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTYOF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BERESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY AREPREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER ISSTRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALLREMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOTTHE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THEENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEWOF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALLDIMENSIONS AND ADVISE AMERICAN TOWER OF ANYDISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING ISSUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICANTOWER.

DESCRIPTIONREV. DATEBY

ATC SITE NUMBER:

ATC SITE NAME:

SITE ADDRESS:

ATC JOB NO:

DRAWN BY:

APPROVED BY:

DATE DRAWN:

SHEET NUMBER: REVISION:

411216

CT CHAPLIN SOUTH CT

CONNECTICUT

123 PALMER RDCHAPLIN, CT 06235

KJ

MCC

04/29/2214071468_C9_04

R-904

A.T. ENGINEERING SERVICE, PLLC3500 REGENCY PARKWAY

SUITE 100CARY, NC 27518

PHONE: (919) 468-0112COA: PEC.0001553

SUPPLEMENTAL

0 FIRST ISSUE KJ 04/29/22

0

DigiSigner Document ID: 289aeaa1-0ba9-459c-b1af-5906f783ae5c

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Post Modification Mount Analysis Report

ATC Site Name : CT Chaplin South CT, CT

ATC Site Number : 411216

Engineering Number : 14071468_C9_04

Mount Elevation : 116 ft

Carrier : T-Mobile

Carrier Site Name : CT508//Verizon Chaplin

Carrier Site Number : CT11508F

Site Location : 123 Palmer Road

Chaplin, CT 06235-2416

41.78454665 , -72.13571997

County : Windham

Date : April 27, 2022

Max Usage : 45%

Result : Contingent Pass

Prepared By:

Mitchell Chen

Structural Engineer II

Reviewed By:

COA: PEC.0001553

Eng. Number 14071468_C9_04 April 27, 2022

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Table of Contents Introduction ....................................................................................................................................................... 1 Supporting Documents ..................................................................................................................................... 1 Analysis ............................................................................................................................................................... 1 Conclusion .......................................................................................................................................................... 1 Application Loading ........................................................................................................................................... 2 Structure Usages................................................................................................................................................ 2 Mount Layout .................................................................................................................................................... 3 Equipment Layout ............................................................................................................................................. 4 Standard Conditions ........................................................................................................................................... 7 Calculations .......................................................................................................................................... Attached

Eng. Number 14071468_C9_04 April 27, 2022

Page 1

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Introduction

The purpose of this report is to summarize results of the mount analysis performed for T-Mobile at 116 ft. Supporting Documents

Specifications Sheet Site Pro 1 RMQP-496-HK, dated May 23, 2021

Radio Frequency Data Sheet RFDS ID #CT11508F, dated March 2, 2022

Reference Photos Site photos from 2020

Analysis

This mount was analyzed using American Tower Corporation’s Mount Analysis Program and RISA-3D

Basic Wind Speed: 120 mph (3-Second Gust)

Basic Wind Speed w/ Ice: 50 mph (3-Second Gust) w/ 1.00'' radial ice concurrent

Codes: ANSI/TIA-222-H

Exposure Category: B

Risk Category: II

Topographic Factor Procedure: Method 2

Feature: Flat

Crest Height (H): 0 ft

Crest Length (L): 0 ft

Spectral Response: Ss = 0.185, S1 = 0.055

Site Class: D - Stiff Soil

Live Loads: Lm = 500 lbs * Based on experience, it has been determined that the Lv load cases will not control over Lm load cases in platform mount analyses. Therefore, these load cases have been excluded from this analysis.

Conclusion

Based on the analysis results, the antenna mount meets the requirements per the applicable codes listed above provided the modifications listed below are completed:

• Install modification per ATC Drawing #14071468_C9_04

If you have any questions or require additional information, please contact American Tower via email at [email protected]. Please include the American Tower site name, site number, and engineering number in the subject line for any questions.

Eng. Number 14071468_C9_04 April 27, 2022

Page 2

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Application Loading

Mount Centerline

(ft)

Equipment Centerline

(ft) Qty Equipment Manufacturer & Model

116.0 117.0

3 Commscope VV-65A-R1

3 Ericsson AIR 6419 B41

3 RFS APXVAARR24_43-U-NA20

3 Ericsson Radio 4449 B71 B85A

3 Ericsson 4460 BAND 2/25

Structure Usages

Structural Component Controlling Usage Pass/Fail

Horizontals 28% Pass

Tie-Backs 10% Pass

Mount Pipes 45% Pass

Connection Check 15% Pass

Eng. Number 14071468_C9_04 April 27, 2022

Page 3

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Mount Layout

Eng. Number 14071468_C9_04 April 27, 2022

Page 4

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Equipment Layout

Mount Pipe A Mount Pipe B

Mount Pipe C Mount Pipe D

Eng. Number 14071468_C9_04 April 27, 2022

Page 5

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Equipment Layout Cont'd.

Mount Pipe E Mount Pipe F

Mount Pipe G Mount Pipe H

Eng. Number 14071468_C9_04 April 27, 2022

Page 6

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Equipment Layout Cont'd.

Mount Pipe I Mount Pipe J

Mount Pipe K Mount Pipe L

Eng. Number 14071468_C9_04 April 27, 2022

Page 7

A.T. Engineering Service, PLLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468.0112 Office - 919.466.5414 Fax - www.americantower.com

Standard Conditions

All engineering services performed by A.T. Engineering Service, PLLC are prepared on the basis that the information used is current and correct. This information may consist of, but is not limited to the following:

• Information supplied by the client regarding equipment, mounts and feed line loading

• Information from drawings, design and analysis documents, and field notes in the possession of A.T. Engineering Service, PLLC

It is the responsibility of the client to ensure that the information provided to A.T. Engineering Service, PLLC and used in the performance of our engineering services is correct and complete. American Tower assumes that all structures were constructed in accordance with the drawings and specifications. All connections are to be verified for condition and tightness by the installation contractor preceding any changes to the appurtenance mounting system and/or equipment attached to it. Unless explicitly agreed by both the client and A.T. Engineering Service, PLLC, all services will be performed in accordance with the current revision of ANSI/TIA-222. Installation of all equipment and steel should be confirmed not to cause tower conflicts nor impede the tower climbing pegs. All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. A.T. Engineering Service, PLLC is not responsible for the conclusions, opinions and recommendations made by others based on the information supplied herein.

Site Number:

Project Number:

Carrier:

Mount Elevation:

Date:

Velocity Pressure Coefficient Kz 1.03 Short Period DSRAP SDS

Topographic Factor Kzt 1.00 1 Second DSRAP SD1

Rooftop Wind Speed-up Factor Ks 1.00 Importance Factor I

Shielding Factor Ka 0.90 Response Modification Coefficient R

Ground Elevation Factor Ke 0.98 Seismic Response Coefficient CS

Wind Direction Probability Factor Kd 0.95 Amplification Factor A

Basic Wind Speed V 120 mph Total Weight W lbs

Velocity Pressure qz 35.5 psf Total Shear Force VS lbs

Height Escalation Factor Kiz 1.13 Horizontal Seismic Load Eh lbs

Thickness of Radial Glaze Ice Tiz 1.13 in Vertical Seismic Load Ev lbs

Height Depth Weight EPAN EPAT

in in lbs sqft sqft

54.7 4.6 23.8 5.93 1.43

36.3 9.0 83.3 6.32 1.82

95.9 8.7 127.9 20.24 3.48

15.0 10.5 75.0 1.65 1.31

19.6 12.1 109.0 2.56 1.98

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

#N/A #N/A #N/A #N/A #N/A

Mount Analysis Force Calculations

411216

14071468_C9_04

T-Mobile

116 ft

4/27/2022

114.4

Wind & Ice Load Calculations

Commscope VV-65A-R1

Equipment

1.0

0.088

0.197

Seismic Load Calculations

286.1

286.1

2899.8

1.0

0.099

2.0

sqft

2.22

Model #

Antenna Calculations (Elevations per Application/RFDS)*

7.33

EPANi

7.45

22.68

2.23

2.42

4.49

1.84

Ericsson AIR 6419 B41

RFS APXVAARR24_43-U-NA20

Ericsson Radio 4449 B71 B85A

#N/A

2.62

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

Ericsson 4460 BAND 2/25 3.27

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

EPATiWidth

in

12.1

20.9

24.0

13.2

15.7

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

sqft

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

#N/A

* Equipment with EPA values N/A were not considered in the mount analysis

Site Number:

Project Number:

Carrier:

Mount Elevation:

Date:

Controlling Load Combination 11

Node Label N002

Force in X Fx -974.4 lbs

Force in Y Fy -173.9 lbs

Force in Z Fz 1615.0 lbs

Moment about X Mx -212.6 lb-ft

Moment about Y My 1289.8 lb-ft

Moment about Z Mz -127.8 lb-ft

Bolt Quantity n 4

Bolt Diameter DB 5/8 in

Bolt Edge Distance e 1 in

Bolt Grade A325

Bolt Fy FyB 92 ksi

Bolt Fu FuB 120 ksi Standoff Type

Applied Shear Vu 0.22 k Standoff Member

Applied Tension Tu 1.91 k Member Edge Distance E 2 in

Tensile Strength φTn 20.3 k Member Width w 4 in

Interaction Capacity (Tu+Vu)/φTn 10% Pass Member Thickness t 0.250 in

Member Grade A53 Gr. B

Member Fy FyM 35 ksi

Plate Height H 8 in Member Fu FuM 60 ksi

Plate Width W 8 in Weld Size a 1/4 in

Plate Thickness T 1/2 in Weld Length l 16.0 in

Plate Grade A36 Applied Load Pu 3.8 k

Plate Fy FyP 36 ksi Weld Strength φRn 44.5 k

Plate Fu FuP 58 ksi Weld Capacity Pu/φRn 9% Pass

Shear Capacity φVn 26.9 k

Applied Moment Mu 3.8 k-in Minimum Base Metal Thickness 0.206 in

Flexural Strength φMn 26.1 k-in Controlling Base Metal Thickness 0.250 in

Flexural Capacity Mu/φMn 15% Pass Base Metal Result

Moment Arm b 1.00 in Minimum Thickness tmin 0.14 in

Effective Moment Arm b' 0.69 in No Prying Thickness tnp 0.19 in

Tributary Length p 2.75 in Min Bolt Strength Thickness tc 0.62 k-in

Effective Edge Distance a' 1.31 in Prying Action Bolt Tension Tup 0.00 k

Prying Action Considerations

Acceptable

A.T. Engineering Service, PLLC

411216

14071468_C9_04

T-Mobile

116 ft

4/27/2022

Plate Flexural Capacity

Mount-to-Tower Connection Analysis

Applied Loads from RISA 3D

Bolt Shear and Tensile Capacity

Weld and Base Metal Capacity

Tube

HSS4x4x4

v1.1

CompanyDesignerJob NumberModel Name

::::

American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT

Checked By : -

4/27/202210:16:31 AM

RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 1

CompanyDesignerJob NumberModel Name

::::

American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT

Checked By : -

4/27/202210:16:31 AM

RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 2

CompanyDesignerJob NumberModel Name

::::

American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT

Checked By : -

4/27/202210:16:31 AM

RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 3

CompanyDesignerJob NumberModel Name

::::

American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT

Checked By : -

4/27/202210:16:31 AM

RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 4

CompanyDesignerJob NumberModel Name

::::

American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT

Checked By : -

4/27/202210:16:31 AM

RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 5

CompanyDesignerJob NumberModel Name

::::

American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT

Checked By : -

4/27/202210:16:31 AM

RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 6

CompanyDesignerJob NumberModel Name

::::

American Tower Corp.Mitchell.Chen14071468_C9_04411216, CT Chaplin South CT

Checked By : -

4/27/202210:16:31 AM

RISA-3D Version 19 [ R3D. T-MOBILE @ 411216, CT Chaplin … Page 7

Basic Load Cases

BLC Description Category Y Gravity Nodal Point Distributed Surface(Plate/Wall)1 D DL -1 242 Di IL 24 60 33 W 0 WL 24 964 W 30 WL 48 1925 W 60 WL 48 1926 W 90 WL 24 997 W 120 WL 48 1928 W 150 WL 48 1929 W 180 WL 24 96

10 W 210 WL 48 19211 W 240 WL 48 19212 W 270 WL 24 9913 W 300 WL 48 19214 W 330 WL 48 19215 Wi 0 WL 24 9616 Wi 30 WL 48 19217 Wi 60 WL 48 19218 Wi 90 WL 24 9919 Wi 120 WL 48 19220 Wi 150 WL 48 19221 Wi 180 WL 24 9622 Wi 210 WL 48 19223 Wi 240 WL 48 19224 Wi 270 WL 24 9925 Wi 300 WL 48 19226 Wi 330 WL 48 19227 Ws 0 WL 24 9628 Ws 30 WL 48 19229 Ws 60 WL 48 19230 Ws 90 WL 24 9931 Ws 120 WL 48 19232 Ws 150 WL 48 19233 Ws 180 WL 24 9634 Ws 210 WL 48 19235 Ws 240 WL 48 19236 Ws 270 WL 24 9937 Ws 300 WL 48 19238 Ws 330 WL 48 19239 Ev -Y ELY 6040 Eh -Z ELZ 6041 Eh -X ELX 6042 Lm (1) LL 143 Lm (2) LL 144 Lm (3) LL 145 Lm (4) LL 146 Lm (5) LL 147 Lm (6) LL 148 Lm (7) LL 149 Lm (8) LL 150 Lm (9) LL 151 Lm (10) LL 152 Lm (11) LL 153 Lm (12) LL 1

TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334

This report was prepared for American Tower Corporation by

Structural Analysis ReportStructure : 146 ft Monopole

ATC Site Name : CT Chaplin South CT,CT

ATC Site Number : 411216

Engineering Number : 14071468_C3_03

Proposed Carrier : T-MOBILE

Carrier Site Name : CT508//Verizon Chaplin

Carrier Site Number : CT11508F

Site Location : 123 Palmer RoadChaplin, CT 06235-241641.7845, -72.1357

County : Windham

Date : May 3, 2022

Max Usage : 72%

Result : Pass

Prepared By:

Ravi Siddharth RajaCLS

Reviewed By:

Digitally signed by David W Chickering Date: 2022.05.03 16:54:28 -04'00'

Eng. Number 14071468_C3_03May 3, 2022

Page. 2

TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334

Table of Contents

Introduction...................................................................................................................................3Supporting Documents ..................................................................................................................3Analysis ..........................................................................................................................................3Conclusion .....................................................................................................................................3Existing and Reserved Equipment..................................................................................................4Equipment to be Removed ............................................................................................................4Proposed Equipment .....................................................................................................................4Structure Usages............................................................................................................................5Foundations ...................................................................................................................................5Deflection and Sway* ....................................................................................................................5Standard Conditions ......................................................................................................................6Calculations …………………………………………………………..Attached

Eng. Number 14071468_C3_03May 3, 2022

Page. 3

TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334

IntroductionThe purpose of this report is to summarize results of a structural analysis performed on the 146 ft Monopole to reflect the change in loading by T-MOBILE.

Supporting Documents

Tower Drawings EEI Project #12120 Rev. 2, dated November 21, 2003Foundation Drawing EEI Project #12120 Rev. 3, dated December 18, 2003Geotechnical Report GEOServices Project #31-151287M, dated September 8, 2015Mount Analysis ATC Project# 14071468_C8_01, dated April 4, 2022Mount Modifications ATC Project# 14071468_C9_04, dated April 29, 2022

AnalysisThe tower was analyzed using American Tower Corporation’s tower analysis software. This program considers an elastic three-dimensional model and second-order effects per ANSI/TIA-222.

Basic Wind Speed: 120 mph (3-second gust)Basic Wind Speed w/ Ice: 50 mph (3-second gust) w/ 1.00" radial ice concurrentCode: ANSI/TIA-222-H / 2015 IBC / 2018 Connecticut State Building CodeExposure Category: BRisk Category: IITopographic Factor Procedure: Method 1Topographic Category: 1Crest Height (H): 0 ftCrest Length (L): 0 ft Spectral Response: Ss = 0.18, S1 = 0.06Site Class: D - Stiff Soil - Default

ConclusionBased on the analysis results, the structure meets the requirements per the applicable codes listed above. The tower and foundation can support the equipment as described in this report.

If you have any questions or require additional information, please contact American Tower via email at [email protected]. Please include the American Tower site name, site number, and engineering number in the subject line for any questions.

Eng. Number 14071468_C3_03May 3, 2022

Page. 4

TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334

Existing and Reserved Equipment

Elev.1 (ft) Qty Equipment Mount Type Lines Carrier

3 Samsung MT6407-77A

6 Andrew SBNHH-1D65B2 Antel LPA-80063/4CF

148.0

4 Antel LPA-80080/4CF ___3 Samsung B5/B13 RRH-BR04C2 Raycap RC3DC-3315-PF-48147.03 Samsung B2/B66A RRH-BR049

Triangular Low Profile Platform

(18) 1 5/8" Coax(2) 1 5/8" Hybriflex VERIZON WIRELESS

6 Alcatel-Lucent RRH2x50-083 Alcatel-Lucent 1900 MHz 4X45 RRH3 Alcatel-Lucent TD-RRH8x20-25 w/ Solar Shield3 RFS APXVTM14-ALU-I203 Commscope NNVV-65B-R4

137.0

1 Generic GPS

Triangular Platform with Handrails

(4) 1 1/4" HybriflexCable

(7) 1 5/8" CoaxSPRINT NEXTEL

3 CCI OPA65R-BU8D3 CCI DMP65R-BU8D3 Allgon 7770.003 Ericsson RRUS 4449 B5, B123 Ericsson RRUS 4478 B143 Ericsson Radio 8843 - B2 + B66A3 Raycap DC6-48-60-18-8F

128.0

6 Powerwave Allgon LGP21401

Triangular Platform with Handrails

(2) 0.39" (10mm)Fiber Trunk

(6) 0.78" (19.7mm)8 AWG 6

(6) 1 5/8" Coax(3) 2" conduit

AT&T MOBILITY

117.0 3 RFS APXVAARR24_43-U-NA20 Triangular Platform with Handrails - T-MOBILE

3 Fujitsu TA08025-B6043 Fujitsu TA08025-B6053 Commscope FFVV-65B-R2

105.0

1 Raycap RDIDC-9181-PF-48

Triangular Platform with Handrails

(1) 1.60" (40.6mm)Hybrid DISH WIRELESS L.L.C.

63.0 1 Generic GPS Stand-Off (1) 1/2" Coax AT&T MOBILITY

Equipment to be Removed

Elev.1 (ft) Qty Equipment Mount Type Lines Carrier

3 Ericsson KRY 112 144/13 Ericsson KRY 112 489/23 RFS APXV18-206517

116.0

3 Ericsson Radio 4449 B12,B71

-(1) 1 5/8" (1.63"-

41.3mm) Fiber(12) 1 5/8" Coax

T-MOBILE

Proposed EquipmentElev.1 (ft) Qty Equipment Mount Type Lines Carrier

3 Ericsson Radio 4449 B71 B85A3 Ericsson 4460 BAND 2/253 Commscope VV-65A-R1

117.0

3 Ericsson AIR 6419 B41

Triangular Platform with Handrails

(1) 1 1/4" HybriflexCable

(2) 1.99" (50.7mm)Hybrid

T-MOBILE

1 Contracted elevations are shown for appurtenances within contracted installation tolerances. Appurtenances outside of contract limits are shown at installed elevations.

Install proposed lines inside the pole shaft.

Eng. Number 14071468_C3_03May 3, 2022

Page. 5

TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334

Structure Usages

Structural Component Controlling Usage Pass/Fail

Anchor Bolts 55% PassShaft 67% Pass

Base Plate 51% Pass

Foundations

ReactioComponent Original Design Reactions

Factored Design Reactions* Analysis Reactions % of Design

Moment (Kips-Ft) 3157.8 4263.0 3064.9 72%Shear (Kips) 30.5 41.2 27.7 67%

* The design reactions are factored by 1.35 per ANSI/TIA-222-H, Sec. 15.6.2

The structure base reactions resulting from this analysis are acceptable when compared to those shown on the original structure drawings, therefore no modification or reinforcement of the foundation will be required.

Deflection and Sway*

AntennaElevation

(ft)Antenna Carrier Deflection

(ft)

Sway (Rotation)

(°)Ericsson Radio 4449 B71 B85A

Ericsson 4460 BAND 2/25RFS APXVAARR24_43-U-NA20

Ericsson AIR 6419 B41117.0

Commscope VV-65A-R1

T-MOBILE 1.040 1.020

*Deflection and Sway was evaluated considering a design wind speed of 60 mph (3-Second Gust) per ANSI/TIA-222-H

Eng. Number 14071468_C3_03May 3, 2022

Page. 6

TTE PLLC ▪ 319 Chapanoke Road, Suite 118, Raleigh, NC 27603 ▪ Office: (405) 348-5742 ▪ Fax: (405) 341-6334

Standard Conditions

All engineering services performed by A.T. Engineering Service, PLLC are prepared on the basis that the information used is current and correct. This information may consist of, but is not limited to the following:

• Information supplied by the client regarding antenna, mounts and feed line loading

• Information from drawings, design and analysis documents, and field notes in the possession of A.T. Engineering Service, PLLC

It is the responsibility of the client to ensure that the information provided to A.T. Engineering Service, PLLC and used in the performance of our engineering services is correct and complete.

All assets of American Tower Corporation, its affiliates, and subsidiaries (collectively “American Tower”) are inspected at regular intervals. Based upon these inspections and in the absence of information to the contrary, American Tower assumes that all structures were constructed in accordance with the drawings and specifications.

Unless explicitly agreed by both the client and A.T. Engineering Service, PLLC, all services will be performed in accordance with the current revision of ANSI/TIA-222.

All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. A.T. Engineering Service, PLLC is not responsible for the conclusions, opinions and recommendations made by others based on the information supplied herein.

JOB INFORMATIONAsset : 411216, CT Chaplin South CT Height : 146 ftClient : T-MOBILE Base Width : 54.5Code : ANSI/TIA-222-H Shape : 18 Sides

© 2007 - 2020 by ATC LLC. All rights reserved. Page 1 of 2 Model ID : 28148 Scenario : 208553 5/3/2022 15:08:12

SITE PARAMETERSNominal Wind: 120 mph wind with no ice Topo Category: 1

Ice Wind: 50 mph wind with 1" radial Topo Method: Method 1

Base Elev (ft): 0.00 Taper : 0.22000(In/ft) Topo Feature:

Structure Class: II Exposure : B Ss : 0.185 S1 : 0.055

SECTION PROPERTIES

ShaftSection

Length(ft)

Diameter (in)

Thick(in)

Joint Type

OverlapLength

(in) Shape

Steel Grade

(ksi)

Across Flats

Top Bottom

1 53.080 42.82 54.50 0.375 0.000 18 Sides 652 51.540 33.46 44.80 0.312 Slip Joint 74.000 18 Sides 653 52.463 23.50 35.04 0.250 Slip Joint 59.000 18 Sides 65

DISCRETE APPURTENANCE

AttachElev (ft)

ForceElev (ft) Qty Description

146.0 147.0 3 Samsung B2/B66A RRH-BR049146.0 147.0 3 Samsung B5/B13 RRH-BR04C146.0 147.0 2 Raycap RC3DC-3315-PF-48146.0 148.0 3 Samsung MT6407-77A146.0 148.0 4 Antel LPA-80080/4CF ___146.0 148.0 2 Antel LPA-80063/4CF146.0 148.0 6 Andrew SBNHH-1D65B146.0 146.0 1 Generic Flat Low Profile Platf137.5 137.5 1 Generic Round Platform with Ha137.0 137.0 1 Generic GPS137.0 137.0 6 Alcatel-Lucent RRH2x50-08137.0 137.0 3 Alcatel-Lucent 1900 MHz 4X45 R137.0 137.0 3 Alcatel-Lucent TD-RRH8x20-25 w137.0 137.0 3 RFS APXVTM14-ALU-I20137.0 137.0 3 Commscope NNVV-65B-R4128.0 126.0 6 Powerwave Allgon LGP21401128.0 126.0 3 Raycap DC6-48-60-18-8F128.0 128.0 3 Ericsson Radio 8843 - B2 + B66128.0 128.0 3 Ericsson RRUS 4478 B14128.0 128.0 3 Ericsson RRUS 4449 B5, B12128.0 126.0 3 Allgon 7770.00128.0 128.0 1 Generic Mount Reinforcement128.0 128.0 3 CCI DMP65R-BU8D128.0 128.0 3 CCI OPA65R-BU8D128.0 128.0 1 Generic Round Platform with Ha117.0 117.0 3 Ericsson Radio 4449 B71 B85A117.0 117.0 3 Ericsson 4460 BAND 2/25117.0 117.0 3 Commscope VV-65A-R1117.0 117.0 3 Ericsson AIR 6419 B41117.0 117.0 3 RFS APXVAARR24_43-U-NA20116.0 116.0 2 Generic Mount Reinforcement116.0 116.0 1 Generic Round Platform with Ha105.0 105.0 1 Raycap RDIDC-9181-PF-48105.0 105.0 3 Fujitsu TA08025-B605105.0 105.0 3 Fujitsu TA08025-B604105.0 105.0 3 Commscope FFVV-65B-R2105.0 105.0 1 Generic Round Platform with Ha75.0 75.0 1 Generic Flat Stand-Off63.0 63.0 1 Generic GPS63.0 63.0 1 Generic Flat Stand-Off

JOB INFORMATIONAsset : 411216, CT Chaplin South CT Height : 146 ftClient : T-MOBILE Base Width : 54.5Code : ANSI/TIA-222-H Shape : 18 Sides

© 2007 - 2020 by ATC LLC. All rights reserved. Page 2 of 2 Model ID : 28148 Scenario : 208553 5/3/2022 15:08:12

LINEAR APPURTENANCEElev

From (ft)Elev

To (ft) Description Exp To Wind

0.0 149.0 1 5/8" Coax No0.0 148.0 1 5/8" Coax No0.0 147.0 1 5/8" Hybriflex No0.0 137.0 1 5/8" Coax No0.0 137.0 1 1/4" Hybriflex Cable No0.0 128.0 2" conduit No0.0 128.0 1 5/8" Coax No0.0 128.0 0.78" (19.7mm) 8 AWG 6 No0.0 128.0 0.39" (10mm) Fiber Trunk No0.0 117.0 1.99" (50.7mm) Hybrid No0.0 117.0 1 1/4" Hybriflex Cable No0.0 105.0 1.60" (40.6mm) Hybrid No0.0 63.0 1/2" Coax Yes

LOAD CASES1.2D + 1.0W 120 mph wind with no ice0.9D + 1.0W 120 mph wind with no ice1.2D + 1.0Di + 1.0Wi 50 mph wind with 1" radial ice1.2D + 1.0Ev + 1.0Eh Seismic0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL)1.0D + 1.0W 60 mph Wind with No Ice

REACTIONS

Load CaseMoment

(kip-ft)Shear(Kip)

Axial(Kip)

1.2D + 1.0W 3064.77 27.74 56.180.9D + 1.0W 3016.64 27.72 42.131.2D + 1.0Di + 1.0Wi 785.58 7.19 74.181.2D + 1.0Ev + 1.0Eh 177.40 1.41 56.400.9D - 1.0Ev + 1.0Eh 173.88 1.41 39.151.0D + 1.0W 679.02 6.20 46.85

DISH DEFLECTIONS

Load CaseAttach

Elev (ft)Deflection

(in)Rotation

(deg)

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 1 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

ANALYSIS PARAMETERS

Location: Windham County,CT Height: 146 ft

Type and Shape: Taper, 18 Sides Base Diameter: 54.50 in

Manufacturer: EEI Top Diameter: 23.50 in

Kd (non-service): 0.95 Taper: 0.2200 in/ft

Ke: 0.98 Rotation: 0.000o

ICE & WIND PARAMETERS

Exposure Category: B Design Wind Speed w/o Ice: 120 mph

Risk Category: II Design Wind Speed w/Ice: 50 mph

Topo Factor Procedure: Method 1 Operational Wind Speed: 60 mph

Topographic Category: 1 Design Ice Thickness: 1.00 in

Crest Height: 0 ft HMSL: 505.00 ft

SEISMIC PARAMETERS

Analysis Method: Equivalent Lateral Force Method

Site Class: D - Stiff Soil Period Based on Rayleigh Method (sec): 2.71

TL (sec): 6 P: 1 Cs: 0.030

Ss: 0.185 S1: 0.055 Cs Max: 0.030

Fa: 1.600 Fv: 2.400 Cs Min: 0.030

Sds: 0.197 Sd1: 0.088

LOAD CASES

1.2D + 1.0W 120 mph wind with no ice 0.9D + 1.0W 120 mph wind with no ice 1.2D + 1.0Di + 1.0Wi 50 mph wind with 1" radial ice 1.2D + 1.0Ev + 1.0Eh Seismic 0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL) 1.0D + 1.0W 60 mph Wind with No Ice

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 2 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

SHAFT SECTION PROPERTIES

Bottom.

Top

Sect Info

Length(ft)

Thick(in)

Fy(ksi)

JointType

Slip Joint

len (in)Weight

(lb)Dia (in)

Elev(ft)

Area (in2)

Ix(in4)

W/t Ratio

D/t Ratio

Dia (in)

Elev (in)

Area (in2)

Ix(in4)

W/tRatio

D/t Ratio

Taper (in/ft)

1-18 53.08 0.3750 65 0.00 10,380 54.50 0.000 64.42 23,843.5 24.22 145.33 42.82 53.08 50.52 11,499.1 18.72 114.19 0.22002-18 51.54 0.3125 65 Slip 74.00 6,753 44.80 46.910 44.13 11,035.0 23.87 143.37 33.46 98.45 32.88 4,564.6 17.47 107.08 0.22003-18 52.46 0.2500 65 Slip 59.00 4,111 35.04 93.537 27.61 4,222.5 23.31 140.17 23.50 146.00 18.45 1,259.8 15.16 94.00 0.2200

Shaft Weight 21,244DISCRETE APPURTENANCE PROPERTIES

AttachElev

(ft) Description Qty Ka

VertEcc(ft)

. No Ice . . Ice .Weight

(lb)EPAa

(sf)Orientation

FactorWeight

(lb)EPAa

(sf)Orientation

Factor

146.00 Samsung MT6407-77A 3 0.80 2.000 81.60 4.709 0.61 149.48 5.721 0.61146.00 Samsung B5/B13 RRH-BR04C 3 0.80 1.000 70.30 1.875 0.50 108.40 2.476 0.50146.00 Samsung B2/B66A RRH-BR049 3 0.80 1.000 84.40 1.875 0.50 126.89 2.476 0.50146.00 Raycap RC3DC-3315-PF-48 2 0.80 1.000 32.00 3.781 0.50 104.86 4.663 0.50146.00 Generic Flat Low Profile Platf 1 1.00 0.000 1875.00 26.100 1.00 2414.37 38.815 1.00146.00 Antel LPA-80080/4CF ___ 4 0.80 2.000 12.00 5.399 0.62 95.71 3.166 0.62146.00 Antel LPA-80063/4CF 2 0.80 2.000 20.00 6.142 0.82 149.92 6.819 0.82146.00 Andrew SBNHH-1D65B 6 0.80 2.000 50.70 8.173 0.69 167.56 10.058 0.69137.50 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3572.46 43.385 1.00137.00 RFS APXVTM14-ALU-I20 3 0.75 0.000 56.20 6.342 0.66 147.29 7.783 0.66137.00 Commscope NNVV-65B-R4 3 0.75 0.000 77.40 12.271 0.64 243.62 14.126 0.64137.00 Alcatel-Lucent TD-RRH8x20-25 w 3 0.75 0.000 70.00 4.046 0.50 132.52 4.924 0.50137.00 Alcatel-Lucent 1900 MHz 4X45 R 3 0.75 0.000 60.00 2.322 0.50 113.31 3.037 0.50137.00 Alcatel-Lucent RRH2x50-08 6 0.75 0.000 52.90 1.701 0.50 92.10 2.272 0.50137.00 Generic GPS 1 1.00 0.000 10.00 0.900 1.00 29.36 1.323 1.00128.00 CCI OPA65R-BU8D 3 0.75 0.000 76.50 18.089 0.63 302.96 20.514 0.63128.00 CCI DMP65R-BU8D 3 0.75 0.000 95.70 17.871 0.63 318.92 20.291 0.63128.00 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3563.75 43.254 1.00128.00 Generic Mount Reinforcement 1 1.00 0.000 200.00 7.500 1.00 327.10 12.417 1.00128.00 Allgon 7770.00 3 0.75 -2.000 35.00 5.508 0.65 116.75 6.183 0.65128.00 Ericsson RRUS 4449 B5, B12 3 0.75 0.000 71.00 1.969 0.50 113.33 2.582 0.50128.00 Ericsson RRUS 4478 B14 3 0.75 0.000 59.90 1.842 0.50 96.21 2.431 0.50128.00 Ericsson Radio 8843 - B2 + B66 3 0.75 0.000 71.90 1.650 0.50 112.36 2.206 0.50128.00 Raycap DC6-48-60-18-8F 3 0.75 -2.000 20.00 1.260 0.50 54.58 1.692 0.50128.00 Powerwave Allgon LGP21401 6 0.75 -2.000 14.10 1.104 0.50 30.49 1.573 0.50117.00 RFS APXVAARR24_43-U-NA20 3 0.75 0.000 127.90 20.243 0.63 383.62 22.659 0.63117.00 Ericsson AIR 6419 B41 3 0.75 0.000 83.30 6.322 0.63 181.88 7.424 0.63117.00 Commscope VV-65A-R1 3 0.75 0.000 23.80 5.928 0.63 100.28 7.308 0.63117.00 Ericsson 4460 BAND 2/25 3 0.75 0.000 109.00 2.564 0.50 166.57 3.250 0.50117.00 Ericsson Radio 4449 B71 B85A 3 0.75 0.000 75.00 1.650 0.50 114.17 2.203 0.50116.00 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3554.12 43.108 1.00116.00 Generic Mount Reinforcement 2 1.00 0.000 200.00 7.500 1.00 325.95 12.373 1.00105.00 Commscope FFVV-65B-R2 3 0.75 0.000 70.80 12.271 0.64 232.41 14.074 0.64105.00 Generic Round Platform with Ha 1 1.00 0.000 2500.00 27.200 1.00 3541.61 42.920 1.00105.00 Raycap RDIDC-9181-PF-48 1 0.75 0.000 21.90 1.867 0.50 58.50 2.446 0.50105.00 Fujitsu TA08025-B604 3 0.75 0.000 63.90 1.962 0.50 101.40 2.554 0.50105.00 Fujitsu TA08025-B605 3 0.75 0.000 75.00 1.962 0.50 115.29 2.554 0.5075.00 Generic Flat Stand-Off 1 1.00 0.000 187.50 6.300 1.00 270.26 8.236 1.0063.00 Generic Flat Stand-Off 1 1.00 0.000 187.50 6.300 1.00 268.91 8.204 1.0063.00 Generic GPS 1 1.00 0.000 10.00 0.900 1.00 27.88 1.291 1.00

Totals Num Loadings: 40 105 18,425.90 31,510.24LINEAR APPURTENANCE PROPERTIES

Load Case Azimuth (deg) : 90.00

ElevFrom

(ft)

ElevTo(ft) Qty Description

CoaxDia(in)

CoaxWt

(lb/ft) Flat

MaxCoax/

Row

DistBetweenRows(in)

DistBetweenCols(in)

Azimuth (deg)

DistFromFace

(in)Exposed To Wind Carrier

0.00 149.00 6 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N VERIZON WIREL0.00 148.00 12 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N VERIZON WIREL0.00 147.00 2 1 5/8" Hybriflex 1.98 1.3 N 0 0 0 0 0 N VERIZON WIREL0.00 137.00 7 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N SPRINT NEXTEL0.00 137.00 4 1 1/4" Hybriflex Cabl 1.54 1 N 0 0 0 0 0 N SPRINT NEXTEL0.00 128.00 6 0.78" (19.7mm) 8 AWG 0.78 0.59 N 0 0 0 0 0 N AT&T MOBILITY

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 3 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

ElevFrom

(ft)

ElevTo(ft) Qty Description

CoaxDia(in)

CoaxWt

(lb/ft) Flat

MaxCoax/

Row

DistBetweenRows(in)

DistBetweenCols(in)

Azimuth (deg)

DistFromFace

(in)Exposed To Wind Carrier

0.00 128.00 6 1 5/8" Coax 1.98 0.82 N 0 0 0 0 0 N AT&T MOBILITY0.00 128.00 3 2" conduit 2.38 3.65 N 0 0 0 0 0 N AT&T MOBILITY0.00 128.00 2 0.39" (10mm) Fiber Tr 0.39 0.06 N 0 0 0 0 0 N AT&T MOBILITY0.00 117.00 2 1.99" (50.7mm) Hybrid 1.99 1.9 N 0 0 0 0 0 N T-MOBILE0.00 117.00 1 1 1/4" Hybriflex Cabl 1.54 1 N 0 0 0 0 0 N T-MOBILE0.00 105.00 1 1.60" (40.6mm) Hybrid 1.6 2.34 N 1 0 0 0 0 N DISH WIRELESS0.00 63.00 1 1/2" Coax 0.63 0.15 N 1 1 1 180 1 Y AT&T MOBILITY

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 4 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

SEGMENT PROPERTIES(Max Len: 5.ft) .

Seg TopElev (ft)

Description Thick(in)

Flat Dia(in)

Area(in2)

Ix(in4)

W/t Ratio

D/t Ratio

F'y (ksi)

S(in3)

Z(in3)

Weight (lb)

0.00 0.3750 54.500 64.420 23,843.50 24.22 145.33 72.9 861.7 0.0 0.0 5.00 0.3750 53.400 63.111 22,418.80 23.70 142.40 73.5 826.9 0.0 1,084.9

10.00 0.3750 52.300 61.801 21,052.10 23.18 139.47 74.1 792.8 0.0 1,062.6 15.00 0.3750 51.199 60.492 19,742.10 22.66 136.53 74.7 759.5 0.0 1,040.3 20.00 0.3750 50.099 59.182 18,487.60 22.15 133.60 75.4 726.8 0.0 1,018.1 25.00 0.3750 48.999 57.873 17,287.30 21.63 130.66 76 694.9 0.0 995.8 30.00 0.3750 47.899 56.563 16,140.20 21.11 127.73 76.6 663.7 0.0 973.5 35.00 0.3750 46.799 55.254 15,045.00 20.59 124.80 77.2 633.2 0.0 951.2 40.00 0.3750 45.698 53.944 14,000.50 20.08 121.86 77.8 603.4 0.0 928.9 45.00 0.3750 44.598 52.635 13,005.50 19.56 118.93 78.4 574.4 0.0 906.7 46.91 Bot - Section 2 0.3750 44.177 52.134 12,637.60 19.36 117.81 78.6 563.4 0.0 341.1 50.00 0.3750 43.498 51.325 12,058.80 19.04 115.99 79 546.0 0.0 1,003.3 53.08 Top - Section 1 0.3125 43.445 42.781 10,055.80 23.10 139.03 74.2 455.9 0.0 985.6 55.00 0.3125 43.023 42.362 9,763.20 22.86 137.67 74.5 447.0 0.0 278.1 60.00 0.3125 41.923 41.271 9,028.00 22.24 134.15 75.2 424.2 0.0 711.5 63.00 0.3125 41.263 40.616 8,605.10 21.87 132.04 75.7 410.8 0.0 418.0 65.00 0.3125 40.822 40.179 8,330.70 21.62 130.63 76 401.9 0.0 274.9 70.00 0.3125 39.722 39.088 7,670.20 21.00 127.11 76.7 380.3 0.0 674.3 75.00 0.3125 38.622 37.997 7,045.60 20.38 123.59 77.4 359.3 0.0 655.8 80.00 0.3125 37.522 36.906 6,455.80 19.76 120.07 78.2 338.9 0.0 637.2 85.00 0.3125 36.422 35.815 5,899.90 19.14 116.55 78.9 319.1 0.0 618.6 90.00 0.3125 35.321 34.723 5,376.90 18.52 113.03 79.6 299.8 0.0 600.1 93.54 Bot - Section 3 0.3125 34.543 33.951 5,026.30 18.08 110.54 80.1 286.6 0.0 413.2 95.00 0.3125 34.221 33.632 4,885.80 17.90 109.51 80.3 281.2 0.0 305.1 98.45 Top - Section 2 0.2500 33.961 26.749 3,840.70 22.54 135.85 74.9 222.7 0.0 708.6

100.00 0.2500 33.621 26.479 3,725.60 22.30 134.48 75.2 218.3 0.0 140.1 105.00 0.2500 32.521 25.606 3,369.10 21.53 130.08 76.1 204.0 0.0 443.1 110.00 0.2500 31.421 24.733 3,036.20 20.75 125.68 77 190.3 0.0 428.2 115.00 0.2500 30.321 23.860 2,725.90 19.97 121.28 77.9 177.1 0.0 413.4 116.00 0.2500 30.100 23.685 2,666.50 19.82 120.40 78.1 174.5 0.0 80.9 117.00 0.2500 29.880 23.511 2,607.90 19.66 119.52 78.3 171.9 0.0 80.3 120.00 0.2500 29.220 22.987 2,437.50 19.20 116.88 78.8 164.3 0.0 237.3 125.00 0.2500 28.120 22.114 2,170.20 18.42 112.48 79.7 152.0 0.0 383.7 128.00 0.2500 27.460 21.590 2,019.60 17.96 109.84 80.3 144.9 0.0 223.1 130.00 0.2500 27.020 21.241 1,923.20 17.65 108.08 80.6 140.2 0.0 145.7 135.00 0.2500 25.920 20.368 1,695.70 16.87 103.68 81.6 128.9 0.0 354.0 137.00 0.2500 25.480 20.019 1,610.00 16.56 101.92 81.9 124.5 0.0 137.4 137.50 0.2500 25.370 19.932 1,589.00 16.48 101.48 82 123.4 0.0 34.0 140.00 0.2500 24.820 19.495 1,486.90 16.09 99.28 82.5 118.0 0.0 167.7 145.00 0.2500 23.719 18.622 1,295.90 15.32 94.88 82.6 107.6 0.0 324.3 146.00 0.2500 23.499 18.448 1,259.80 15.16 94.00 82.6 105.6 0.0 63.1

Totals: 21,243.7

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 5 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Load Case: 1.2D + 1.0W 120 mph wind with no ice 24 IterationsGust Response Factor: 1.10Dead load Factor: 1.20Wind Load Factor: 1.00

CALCULATED FORCES

SegElev

(ft)

PuFY (-)(kips)

VuFX (-)(kips)

TuMY

(ft-kips)

MuMZ

(ft-kips)

MuMX

(ft-kips)

ResultantMoment(ft-kips)

PhiPn

(kips)

PhiVn

(kips)

PhiTn

(ft-kips)

PhiMn

(ft-kips)

TotalDeflect

(in)Rotation

(deg) Ratio

0.00 -56.18 -27.74 0.00 -3,064.8 0.00 3,064.77 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.6645.00 -54.47 -27.47 0.00 -2,926.1 0.00 2,926.07 4,176.31 1,107.59 5,304.49 4,560.00 0.1 -0.18 0.655

10.00 -52.79 -27.21 0.00 -2,788.7 0.00 2,788.71 4,123.50 1,084.61 5,086.68 4,408.26 0.38 -0.36 0.64615.00 -51.13 -26.94 0.00 -2,652.7 0.00 2,652.69 4,069.26 1,061.63 4,873.43 4,257.44 0.86 -0.54 0.63620.00 -49.50 -26.68 0.00 -2,518.0 0.00 2,517.99 4,013.58 1,038.65 4,664.74 4,107.62 1.53 -0.73 0.62625.00 -47.91 -26.41 0.00 -2,384.6 0.00 2,384.62 3,956.47 1,015.67 4,460.63 3,958.90 2.39 -0.92 0.61530.00 -46.33 -26.14 0.00 -2,252.6 0.00 2,252.56 3,897.92 992.68 4,261.08 3,811.39 3.46 -1.11 0.60435.00 -44.79 -25.86 0.00 -2,121.8 0.00 2,121.85 3,837.94 969.70 4,066.09 3,665.19 4.72 -1.3 0.59140.00 -43.28 -25.57 0.00 -1,992.5 0.00 1,992.53 3,776.52 946.72 3,875.67 3,520.38 6.19 -1.5 0.57845.00 -41.81 -25.35 0.00 -1,864.7 0.00 1,864.67 3,713.67 923.74 3,689.82 3,377.07 7.86 -1.69 0.56446.91 -41.24 -25.20 0.00 -1,816.2 0.00 1,816.17 3,689.24 914.95 3,619.91 3,322.65 8.56 -1.77 0.55950.00 -39.79 -24.98 0.00 -1,738.4 0.00 1,738.40 3,649.39 900.76 3,508.54 3,235.36 9.74 -1.89 0.54953.08 -38.38 -24.79 0.00 -1,661.5 0.00 1,661.46 2,857.95 750.80 2,924.98 2,537.94 11.01 -2.02 0.66955.00 -37.86 -24.59 0.00 -1,613.9 0.00 1,613.86 2,840.65 743.45 2,867.97 2,497.68 11.83 -2.09 0.66160.00 -36.62 -24.32 0.00 -1,490.9 0.00 1,490.92 2,794.59 724.30 2,722.13 2,393.44 14.15 -2.32 0.63763.00 -35.66 -23.91 0.00 -1,418.0 0.00 1,417.95 2,766.27 712.81 2,636.46 2,331.31 15.65 -2.46 0.62265.00 -35.15 -23.70 0.00 -1,370.1 0.00 1,370.13 2,747.10 705.15 2,580.10 2,290.09 16.7 -2.55 0.61270.00 -33.95 -23.37 0.00 -1,251.6 0.00 1,251.63 2,698.18 686.00 2,441.88 2,187.75 19.49 -2.77 0.58675.00 -32.56 -22.80 0.00 -1,134.8 0.00 1,134.81 2,647.83 666.85 2,307.46 2,086.52 22.52 -3 0.55780.00 -31.41 -22.45 0.00 -1,020.8 0.00 1,020.84 2,596.04 647.70 2,176.84 1,986.48 25.77 -3.21 0.52785.00 -30.29 -22.10 0.00 -908.6 0.00 908.59 2,542.81 628.54 2,050.03 1,887.74 29.25 -3.43 0.49490.00 -29.21 -21.78 0.00 -798.1 0.00 798.11 2,488.15 609.39 1,927.03 1,790.40 32.95 -3.63 0.45993.54 -28.46 -21.59 0.00 -721.1 0.00 721.07 2,448.63 595.85 1,842.32 1,722.45 35.69 -3.77 0.43295.00 -27.98 -21.41 0.00 -689.5 0.00 689.47 2,432.06 590.24 1,807.83 1,694.56 36.86 -3.83 0.42098.45 -26.88 -21.19 0.00 -615.5 0.00 615.53 1,802.83 469.45 1,429.40 1,251.05 39.68 -3.96 0.509

100.00 -26.59 -20.98 0.00 -582.8 0.00 582.76 1,791.36 464.71 1,400.69 1,230.45 40.97 -4.02 0.490105.00 -22.06 -18.45 0.00 -477.9 0.00 477.86 1,753.33 449.39 1,309.86 1,164.33 45.29 -4.22 0.425110.00 -21.22 -18.08 0.00 -385.6 0.00 385.61 1,713.87 434.07 1,222.08 1,099.03 49.81 -4.41 0.365115.00 -20.41 -17.83 0.00 -295.2 0.00 295.20 1,672.98 418.74 1,137.35 1,034.64 54.51 -4.57 0.299116.00 -16.91 -15.84 0.00 -277.4 0.00 277.37 1,664.63 415.68 1,120.76 1,021.88 55.47 -4.6 0.283117.00 -15.40 -13.59 0.00 -261.5 0.00 261.54 1,656.22 412.62 1,104.30 1,009.16 56.43 -4.62 0.270120.00 -14.95 -13.30 0.00 -220.8 0.00 220.76 1,630.65 403.42 1,055.65 971.26 59.36 -4.7 0.238125.00 -14.22 -12.98 0.00 -154.3 0.00 154.26 1,586.89 388.10 977.01 908.99 64.34 -4.81 0.180128.00 -9.28 -8.22 0.00 -115.3 0.00 115.32 1,559.94 378.91 931.28 872.20 67.38 -4.87 0.139130.00 -9.05 -7.98 0.00 -98.9 0.00 98.87 1,541.69 372.78 901.40 847.93 69.42 -4.9 0.123135.00 -8.48 -7.70 0.00 -59.0 0.00 58.99 1,495.06 357.46 828.84 788.18 74.58 -4.95 0.081137.00 -7.06 -5.90 0.00 -43.6 0.00 43.58 1,476.01 351.33 800.67 764.66 76.66 -4.97 0.062137.50 -4.12 -4.43 0.00 -40.6 0.00 40.63 1,471.21 349.80 793.70 758.82 77.18 -4.97 0.057140.00 -3.89 -4.18 0.00 -29.6 0.00 29.55 1,447.00 342.14 759.33 729.83 79.78 -4.99 0.043145.00 -3.41 -3.95 0.00 -8.7 0.00 8.67 1,383.54 326.82 692.86 666.26 85.01 -5.01 0.016146.00 0.00 -3.64 0.00 -4.7 0.00 4.72 1,370.57 323.76 679.93 653.76 86.06 -5.01 0.007

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 6 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Load Case: 0.9D + 1.0W 120 mph wind with no ice 24 IterationsGust Response Factor: 1.10Dead load Factor: 0.90Wind Load Factor: 1.00

CALCULATED FORCES

SegElev

(ft)

PuFY (-)(kips)

VuFX (-)(kips)

TuMY

(ft-kips)

MuMZ

(ft-kips)

MuMX

(ft-kips)

ResultantMoment(ft-kips)

PhiPn

(kips)

PhiVn

(kips)

PhiTn

(ft-kips)

PhiMn

(ft-kips)

TotalDeflect

(in)Rotation

(deg) Ratio

0.00 -42.13 -27.72 0.00 -3,016.6 0.00 3,016.64 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.6515.00 -40.82 -27.41 0.00 -2,878.1 0.00 2,878.06 4,176.31 1,107.59 5,304.49 4,560.00 0.09 -0.18 0.642

10.00 -39.54 -27.10 0.00 -2,741.0 0.00 2,741.03 4,123.50 1,084.61 5,086.68 4,408.26 0.37 -0.35 0.63215.00 -38.28 -26.79 0.00 -2,605.6 0.00 2,605.56 4,069.26 1,061.63 4,873.43 4,257.44 0.84 -0.53 0.62220.00 -37.04 -26.49 0.00 -2,471.6 0.00 2,471.61 4,013.58 1,038.65 4,664.74 4,107.62 1.5 -0.72 0.61225.00 -35.82 -26.19 0.00 -2,339.2 0.00 2,339.18 3,956.47 1,015.67 4,460.63 3,958.90 2.35 -0.9 0.60130.00 -34.63 -25.88 0.00 -2,208.3 0.00 2,208.26 3,897.92 992.68 4,261.08 3,811.39 3.4 -1.09 0.58935.00 -33.45 -25.57 0.00 -2,078.8 0.00 2,078.84 3,837.94 969.70 4,066.09 3,665.19 4.64 -1.28 0.57740.00 -32.30 -25.25 0.00 -1,951.0 0.00 1,950.98 3,776.52 946.72 3,875.67 3,520.38 6.08 -1.47 0.56345.00 -31.19 -25.01 0.00 -1,824.7 0.00 1,824.74 3,713.67 923.74 3,689.82 3,377.07 7.72 -1.66 0.54946.91 -30.76 -24.84 0.00 -1,776.9 0.00 1,776.89 3,689.24 914.95 3,619.91 3,322.65 8.41 -1.74 0.54450.00 -29.66 -24.62 0.00 -1,700.2 0.00 1,700.21 3,649.39 900.76 3,508.54 3,235.36 9.57 -1.86 0.53453.08 -28.59 -24.42 0.00 -1,624.4 0.00 1,624.39 2,857.95 750.80 2,924.98 2,537.94 10.81 -1.98 0.65155.00 -28.19 -24.19 0.00 -1,577.5 0.00 1,577.51 2,840.65 743.45 2,867.97 2,497.68 11.62 -2.05 0.64360.00 -27.25 -23.91 0.00 -1,456.6 0.00 1,456.55 2,794.59 724.30 2,722.13 2,393.44 13.89 -2.28 0.61963.00 -26.52 -23.49 0.00 -1,384.8 0.00 1,384.82 2,766.27 712.81 2,636.46 2,331.31 15.36 -2.41 0.60565.00 -26.13 -23.25 0.00 -1,337.8 0.00 1,337.84 2,747.10 705.15 2,580.10 2,290.09 16.39 -2.5 0.59570.00 -25.21 -22.90 0.00 -1,221.6 0.00 1,221.58 2,698.18 686.00 2,441.88 2,187.75 19.13 -2.72 0.56975.00 -24.16 -22.31 0.00 -1,107.1 0.00 1,107.10 2,647.83 666.85 2,307.46 2,086.52 22.09 -2.93 0.54180.00 -23.29 -21.95 0.00 -995.5 0.00 995.54 2,596.04 647.70 2,176.84 1,986.48 25.27 -3.15 0.51185.00 -22.44 -21.58 0.00 -885.8 0.00 885.81 2,542.81 628.54 2,050.03 1,887.74 28.68 -3.35 0.47990.00 -21.61 -21.26 0.00 -777.9 0.00 777.90 2,488.15 609.39 1,927.03 1,790.40 32.3 -3.55 0.44493.54 -21.05 -21.07 0.00 -702.7 0.00 702.71 2,448.63 595.85 1,842.32 1,722.45 34.98 -3.69 0.41895.00 -20.68 -20.88 0.00 -671.9 0.00 671.89 2,432.06 590.24 1,807.83 1,694.56 36.12 -3.75 0.40698.45 -19.86 -20.67 0.00 -599.8 0.00 599.77 1,802.83 469.45 1,429.40 1,251.05 38.88 -3.88 0.492

100.00 -19.63 -20.45 0.00 -567.8 0.00 567.81 1,791.36 464.71 1,400.69 1,230.45 40.15 -3.93 0.474105.00 -16.26 -17.98 0.00 -465.6 0.00 465.58 1,753.33 449.39 1,309.86 1,164.33 44.37 -4.13 0.411110.00 -15.62 -17.61 0.00 -375.7 0.00 375.67 1,713.87 434.07 1,222.08 1,099.03 48.8 -4.31 0.353115.00 -15.01 -17.37 0.00 -287.6 0.00 287.61 1,672.98 418.74 1,137.35 1,034.64 53.39 -4.46 0.289116.00 -12.42 -15.45 0.00 -270.2 0.00 270.24 1,664.63 415.68 1,120.76 1,021.88 54.33 -4.49 0.273117.00 -11.33 -13.24 0.00 -254.8 0.00 254.79 1,656.22 412.62 1,104.30 1,009.16 55.27 -4.52 0.260120.00 -10.99 -12.95 0.00 -215.1 0.00 215.08 1,630.65 403.42 1,055.65 971.26 58.14 -4.6 0.229125.00 -10.44 -12.64 0.00 -150.3 0.00 150.34 1,586.89 388.10 977.01 908.99 63.01 -4.7 0.173128.00 -6.81 -8.00 0.00 -112.4 0.00 112.42 1,559.94 378.91 931.28 872.20 65.98 -4.76 0.134130.00 -6.65 -7.76 0.00 -96.4 0.00 96.43 1,541.69 372.78 901.40 847.93 67.97 -4.79 0.118135.00 -6.22 -7.49 0.00 -57.6 0.00 57.65 1,495.06 357.46 828.84 788.18 73.01 -4.84 0.078137.00 -5.19 -5.73 0.00 -42.7 0.00 42.66 1,476.01 351.33 800.67 764.66 75.04 -4.86 0.060137.50 -3.01 -4.33 0.00 -39.8 0.00 39.80 1,471.21 349.80 793.70 758.82 75.55 -4.86 0.055140.00 -2.84 -4.08 0.00 -29.0 0.00 28.98 1,447.00 342.14 759.33 729.83 78.1 -4.88 0.042145.00 -2.49 -3.86 0.00 -8.6 0.00 8.59 1,383.54 326.82 692.86 666.26 83.21 -4.9 0.015146.00 0.00 -3.64 0.00 -4.7 0.00 4.72 1,370.57 323.76 679.93 653.76 84.24 -4.9 0.007

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 7 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Load Case: 1.2D + 1.0Di + 1.0Wi 50 mph wind with 1" radial ice 24 IterationsGust Response Factor: 1.10 Ice Dead Load Factor 1.00Dead load Factor: 1.20 Ice Importance Factor 1.00Wind Load Factor: 1.00

CALCULATED FORCES

SegElev

(ft)

PuFY (-)(kips)

VuFX (-)(kips)

TuMY

(ft-kips)

MuMZ

(ft-kips)

MuMX

(ft-kips)

ResultantMoment(ft-kips)

PhiPn

(kips)

PhiVn

(kips)

PhiTn

(ft-kips)

PhiMn

(ft-kips)

TotalDeflect

(in)Rotation

(deg) Ratio

0.00 -74.18 -7.19 0.00 -785.6 0.00 785.58 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.1845.00 -72.28 -7.11 0.00 -749.7 0.00 749.66 4,176.31 1,107.59 5,304.49 4,560.00 0.02 -0.05 0.182

10.00 -70.39 -7.04 0.00 -714.1 0.00 714.09 4,123.50 1,084.61 5,086.68 4,408.26 0.1 -0.09 0.17915.00 -68.51 -6.97 0.00 -678.9 0.00 678.87 4,069.26 1,061.63 4,873.43 4,257.44 0.22 -0.14 0.17620.00 -66.66 -6.90 0.00 -644.0 0.00 644.01 4,013.58 1,038.65 4,664.74 4,107.62 0.39 -0.19 0.17325.00 -64.83 -6.83 0.00 -609.5 0.00 609.50 3,956.47 1,015.67 4,460.63 3,958.90 0.61 -0.24 0.17030.00 -63.03 -6.76 0.00 -575.4 0.00 575.35 3,897.92 992.68 4,261.08 3,811.39 0.89 -0.28 0.16735.00 -61.26 -6.68 0.00 -541.6 0.00 541.55 3,837.94 969.70 4,066.09 3,665.19 1.21 -0.33 0.16440.00 -59.52 -6.60 0.00 -508.1 0.00 508.13 3,776.52 946.72 3,875.67 3,520.38 1.58 -0.38 0.16045.00 -57.80 -6.54 0.00 -475.1 0.00 475.12 3,713.67 923.74 3,689.82 3,377.07 2.01 -0.43 0.15646.91 -57.16 -6.50 0.00 -462.6 0.00 462.60 3,689.24 914.95 3,619.91 3,322.65 2.19 -0.45 0.15550.00 -55.56 -6.44 0.00 -442.5 0.00 442.54 3,649.39 900.76 3,508.54 3,235.36 2.49 -0.48 0.15253.08 -54.00 -6.39 0.00 -422.7 0.00 422.70 2,857.95 750.80 2,924.98 2,537.94 2.82 -0.52 0.18655.00 -53.42 -6.33 0.00 -410.4 0.00 410.43 2,840.65 743.45 2,867.97 2,497.68 3.03 -0.54 0.18360.00 -51.95 -6.26 0.00 -378.8 0.00 378.77 2,794.59 724.30 2,722.13 2,393.44 3.62 -0.59 0.17763.00 -50.77 -6.16 0.00 -360.0 0.00 359.98 2,766.27 712.81 2,636.46 2,331.31 4 -0.63 0.17365.00 -50.20 -6.10 0.00 -347.7 0.00 347.67 2,747.10 705.15 2,580.10 2,290.09 4.27 -0.65 0.17070.00 -48.79 -6.01 0.00 -317.2 0.00 317.18 2,698.18 686.00 2,441.88 2,187.75 4.98 -0.71 0.16375.00 -47.12 -5.86 0.00 -287.2 0.00 287.15 2,647.83 666.85 2,307.46 2,086.52 5.75 -0.76 0.15580.00 -45.76 -5.76 0.00 -257.9 0.00 257.87 2,596.04 647.70 2,176.84 1,986.48 6.58 -0.82 0.14885.00 -44.44 -5.66 0.00 -229.1 0.00 229.07 2,542.81 628.54 2,050.03 1,887.74 7.47 -0.87 0.13990.00 -43.14 -5.57 0.00 -200.8 0.00 200.78 2,488.15 609.39 1,927.03 1,790.40 8.41 -0.92 0.13093.54 -42.24 -5.51 0.00 -181.1 0.00 181.08 2,448.63 595.85 1,842.32 1,722.45 9.11 -0.96 0.12295.00 -41.71 -5.46 0.00 -173.0 0.00 173.01 2,432.06 590.24 1,807.83 1,694.56 9.41 -0.97 0.11998.45 -40.46 -5.40 0.00 -154.2 0.00 154.15 1,802.83 469.45 1,429.40 1,251.05 10.12 -1.01 0.146

100.00 -40.12 -5.34 0.00 -145.8 0.00 145.80 1,791.36 464.71 1,400.69 1,230.45 10.45 -1.02 0.141105.00 -33.86 -4.68 0.00 -119.1 0.00 119.11 1,753.33 449.39 1,309.86 1,164.33 11.55 -1.07 0.122110.00 -32.81 -4.57 0.00 -95.7 0.00 95.72 1,713.87 434.07 1,222.08 1,099.03 12.7 -1.12 0.106115.00 -31.78 -4.49 0.00 -72.9 0.00 72.89 1,672.98 418.74 1,137.35 1,034.64 13.89 -1.16 0.090116.00 -27.09 -3.92 0.00 -68.4 0.00 68.39 1,664.63 415.68 1,120.76 1,021.88 14.14 -1.16 0.083117.00 -24.15 -3.42 0.00 -64.5 0.00 64.48 1,656.22 412.62 1,104.30 1,009.16 14.38 -1.17 0.079120.00 -23.57 -3.33 0.00 -54.2 0.00 54.22 1,630.65 403.42 1,055.65 971.26 15.12 -1.19 0.070125.00 -22.62 -3.23 0.00 -37.6 0.00 37.57 1,586.89 388.10 977.01 908.99 16.39 -1.22 0.056128.00 -14.53 -2.06 0.00 -27.9 0.00 27.88 1,559.94 378.91 931.28 872.20 17.16 -1.23 0.041130.00 -14.21 -1.98 0.00 -23.8 0.00 23.76 1,541.69 372.78 901.40 847.93 17.67 -1.24 0.037135.00 -13.43 -1.90 0.00 -13.8 0.00 13.84 1,495.06 357.46 828.84 788.18 18.98 -1.25 0.027137.00 -10.71 -1.48 0.00 -10.0 0.00 10.04 1,476.01 351.33 800.67 764.66 19.5 -1.26 0.020137.50 -6.81 -1.05 0.00 -9.3 0.00 9.30 1,471.21 349.80 793.70 758.82 19.63 -1.26 0.017140.00 -6.47 -0.97 0.00 -6.7 0.00 6.67 1,447.00 342.14 759.33 729.83 20.29 -1.26 0.014145.00 -5.79 -0.90 0.00 -1.8 0.00 1.80 1,383.54 326.82 692.86 666.26 21.62 -1.26 0.007146.00 0.00 -0.77 0.00 -0.9 0.00 0.90 1,370.57 323.76 679.93 653.76 21.88 -1.26 0.001

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 8 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Load Case: 1.0D + 1.0W 60 mph Wind with No Ice 23 IterationsGust Response Factor: 1.10Dead load Factor: 1.00Wind Load Factor: 1.00

CALCULATED FORCES

SegElev

(ft)

PuFY (-)(kips)

VuFX (-)(kips)

TuMY

(ft-kips)

MuMZ

(ft-kips)

MuMX

(ft-kips)

ResultantMoment(ft-kips)

PhiPn

(kips)

PhiVn

(kips)

PhiTn

(ft-kips)

PhiMn

(ft-kips)

TotalDeflect

(in)Rotation

(deg) Ratio

0.00 -46.85 -6.20 0.00 -679.0 0.00 679.02 4,227.69 1,130.57 5,526.88 4,712.55 0 0 0.1555.00 -45.49 -6.13 0.00 -648.0 0.00 648.01 4,176.31 1,107.59 5,304.49 4,560.00 0.02 -0.04 0.153

10.00 -44.16 -6.07 0.00 -617.3 0.00 617.34 4,123.50 1,084.61 5,086.68 4,408.26 0.08 -0.08 0.15115.00 -42.84 -6.00 0.00 -587.0 0.00 587.00 4,069.26 1,061.63 4,873.43 4,257.44 0.19 -0.12 0.14820.00 -41.55 -5.94 0.00 -557.0 0.00 556.98 4,013.58 1,038.65 4,664.74 4,107.62 0.34 -0.16 0.14625.00 -40.28 -5.87 0.00 -527.3 0.00 527.29 3,956.47 1,015.67 4,460.63 3,958.90 0.53 -0.2 0.14330.00 -39.04 -5.81 0.00 -497.9 0.00 497.91 3,897.92 992.68 4,261.08 3,811.39 0.77 -0.25 0.14135.00 -37.81 -5.74 0.00 -468.9 0.00 468.87 3,837.94 969.70 4,066.09 3,665.19 1.05 -0.29 0.13840.00 -36.61 -5.67 0.00 -440.2 0.00 440.15 3,776.52 946.72 3,875.67 3,520.38 1.37 -0.33 0.13545.00 -35.43 -5.62 0.00 -411.8 0.00 411.79 3,713.67 923.74 3,689.82 3,377.07 1.74 -0.37 0.13246.91 -34.98 -5.59 0.00 -401.0 0.00 401.03 3,689.24 914.95 3,619.91 3,322.65 1.89 -0.39 0.13050.00 -33.81 -5.54 0.00 -383.8 0.00 383.79 3,649.39 900.76 3,508.54 3,235.36 2.16 -0.42 0.12853.08 -32.66 -5.49 0.00 -366.7 0.00 366.74 2,857.95 750.80 2,924.98 2,537.94 2.44 -0.45 0.15655.00 -32.27 -5.44 0.00 -356.2 0.00 356.20 2,840.65 743.45 2,867.97 2,497.68 2.62 -0.46 0.15460.00 -31.29 -5.38 0.00 -329.0 0.00 328.98 2,794.59 724.30 2,722.13 2,393.44 3.13 -0.51 0.14963.00 -30.51 -5.29 0.00 -312.8 0.00 312.83 2,766.27 712.81 2,636.46 2,331.31 3.46 -0.54 0.14565.00 -30.13 -5.24 0.00 -302.2 0.00 302.25 2,747.10 705.15 2,580.10 2,290.09 3.69 -0.56 0.14370.00 -29.18 -5.16 0.00 -276.0 0.00 276.05 2,698.18 686.00 2,441.88 2,187.75 4.31 -0.61 0.13775.00 -28.06 -5.03 0.00 -250.2 0.00 250.24 2,647.83 666.85 2,307.46 2,086.52 4.98 -0.66 0.13180.00 -27.16 -4.95 0.00 -225.1 0.00 225.08 2,596.04 647.70 2,176.84 1,986.48 5.7 -0.71 0.12485.00 -26.27 -4.87 0.00 -200.3 0.00 200.31 2,542.81 628.54 2,050.03 1,887.74 6.47 -0.76 0.11790.00 -25.39 -4.80 0.00 -175.9 0.00 175.94 2,488.15 609.39 1,927.03 1,790.40 7.29 -0.8 0.10993.54 -24.79 -4.76 0.00 -159.0 0.00 158.96 2,448.63 595.85 1,842.32 1,722.45 7.89 -0.83 0.10295.00 -24.41 -4.72 0.00 -152.0 0.00 151.99 2,432.06 590.24 1,807.83 1,694.56 8.15 -0.85 0.10098.45 -23.51 -4.67 0.00 -135.7 0.00 135.69 1,802.83 469.45 1,429.40 1,251.05 8.77 -0.88 0.122

100.00 -23.29 -4.62 0.00 -128.5 0.00 128.47 1,791.36 464.71 1,400.69 1,230.45 9.06 -0.89 0.118105.00 -19.43 -4.07 0.00 -105.4 0.00 105.35 1,753.33 449.39 1,309.86 1,164.33 10.01 -0.93 0.102110.00 -18.74 -3.98 0.00 -85.0 0.00 85.02 1,713.87 434.07 1,222.08 1,099.03 11.01 -0.97 0.088115.00 -18.07 -3.93 0.00 -65.1 0.00 65.09 1,672.98 418.74 1,137.35 1,034.64 12.05 -1.01 0.074116.00 -15.05 -3.49 0.00 -61.2 0.00 61.16 1,664.63 415.68 1,120.76 1,021.88 12.26 -1.01 0.069117.00 -13.66 -3.00 0.00 -57.7 0.00 57.67 1,656.22 412.62 1,104.30 1,009.16 12.48 -1.02 0.065120.00 -13.29 -2.93 0.00 -48.7 0.00 48.68 1,630.65 403.42 1,055.65 971.26 13.12 -1.04 0.058125.00 -12.67 -2.86 0.00 -34.0 0.00 34.02 1,586.89 388.10 977.01 908.99 14.22 -1.06 0.045128.00 -8.25 -1.81 0.00 -25.4 0.00 25.44 1,559.94 378.91 931.28 872.20 14.9 -1.07 0.034130.00 -8.05 -1.76 0.00 -21.8 0.00 21.82 1,541.69 372.78 901.40 847.93 15.35 -1.08 0.031135.00 -7.56 -1.70 0.00 -13.0 0.00 13.03 1,495.06 357.46 828.84 788.18 16.49 -1.09 0.022137.00 -6.26 -1.30 0.00 -9.6 0.00 9.64 1,476.01 351.33 800.67 764.66 16.95 -1.1 0.017137.50 -3.72 -0.98 0.00 -9.0 0.00 8.99 1,471.21 349.80 793.70 758.82 17.06 -1.1 0.014140.00 -3.51 -0.92 0.00 -6.5 0.00 6.54 1,447.00 342.14 759.33 729.83 17.64 -1.1 0.011145.00 -3.10 -0.87 0.00 -1.9 0.00 1.93 1,383.54 326.82 692.86 666.26 18.79 -1.11 0.005146.00 0.00 -0.81 0.00 -1.1 0.00 1.06 1,370.57 323.76 679.93 653.76 19.02 -1.11 0.002

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 9 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

EQUIVALENT LATERAL FORCES METHOD ANALYSIS (Based on ASCE7-16 Chapters 11, 12 and 15)

Spectral Response Acceleration for Short Period (SS): 0.185

Spectral Response Acceleration at 1.0 Second Period (S1): 0.055

Long-Period Transition Period (TL – Seconds): 6

Importance Factor (Ie): 1.000

Site Coefficient Fa: 1.600

Site Coefficient Fv: 2.400

Response Modification Coefficient (R): 1.500

Design Spectral Response Acceleration at Short Period (Sds): 0.197

Design Spectral Response Acceleration at 1.0 Second Period (Sd1): 0.088

Seismic Response Coefficient (Cs): 0.030

Upper Limit CS: 0.030

Lower Limit CS: 0.030

Period based on Rayleigh Method (sec): 2.710

Redundancy Factor (p): 1.000

Seismic Force Distribution Exponent (k): 2.000

Total Unfactored Dead Load: 46.850 k

Seismic Base Shear (E): 1.410 k

1.2D + 1.0Ev + 1.0Eh Seismic

Segment

Height AboveBase

(ft)Weight

(lb)Wz

(lb-ft) Cvx

HorizontalForce

(lb)

VerticalForce

(lb)

40 145.5 80 1,703 0.004 5 10039 142.5 411 8,347 0.019 27 50938 138.75 211 4,064 0.009 13 26237 137.25 43 804 0.002 3 5336 136 192 3,544 0.008 11 23835 132.5 489 8,593 0.020 27 60734 129 200 3,327 0.008 11 24833 126.5 363 5,808 0.013 19 45032 122.5 617 9,256 0.021 30 76531 118.5 377 5,297 0.012 17 46830 116.5 132 1,788 0.004 6 16329 115.5 132 1,765 0.004 6 16428 112.5 671 8,486 0.019 27 83127 107.5 685 7,920 0.018 25 85026 102.5 712 7,480 0.017 24 88225 99.2267 223 2,198 0.005 7 27724 96.7267 894 8,367 0.019 27 1,10823 94.2683 384 3,410 0.008 11 47622 91.7683 603 5,081 0.012 16 74821 87.5 869 6,653 0.015 21 1,07720 82.5 887 6,040 0.014 19 1,10019 77.5 906 5,442 0.012 17 1,12318 72.5 925 4,860 0.011 16 1,14617 67.5 943 4,297 0.010 14 1,16916 64 382 1,567 0.004 5 47415 61.5 580 2,193 0.005 7 71914 57.5 981 3,244 0.007 10 1,21613 54.04 382 1,115 0.002 4 47312 51.54 1,152 3,059 0.007 10 1,42711 48.4567 1,170 2,747 0.006 9 1,45010 45.9567 444 938 0.002 3 5519 42.5 1,176 2,125 0.005 7 1,4588 37.5 1,199 1,685 0.004 5 1,4867 32.5 1,221 1,289 0.003 4 1,513

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 10 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Segment

Height AboveBase

(ft)Weight

(lb)Wz

(lb-ft) Cvx

HorizontalForce

(lb)

VerticalForce

(lb)

6 27.5 1,243 940 0.002 3 1,5415 22.5 1,265 641 0.002 2 1,5684 17.5 1,288 394 0.001 1 1,5963 12.5 1,310 205 0.000 1 1,6242 7.5 1,332 75 0.000 0 1,6511 2.5 1,354 8 0.000 0 1,679Samsung B5/B13 RRH-BR04C 146 211 4,496 0.010 14 261Samsung B2/B66A RRH-BR049 146 253 5,397 0.012 17 314Raycap RC3DC-3315-PF-48 146 64 1,364 0.003 4 79Samsung MT6407-77A 146 245 5,218 0.012 17 303Antel LPA-80080/4CF ___ 146 48 1,023 0.002 3 59Antel LPA-80063/4CF 146 40 853 0.002 3 50Andrew SBNHH-1D65B 146 304 6,484 0.015 21 377Generic Flat Low Profile Platform 146 1,875 39,968 0.091 128 2,324Generic Round Platform with Handrails 137.5 2,500 47,266 0.108 151 3,099Generic Round Platform with Handrails 128 2,500 40,960 0.093 131 3,099Generic Round Platform with Handrails 116 2,500 33,640 0.077 108 3,099Generic Round Platform with Handrails 105 2,500 27,562 0.063 88 3,099Generic GPS 137 10 188 0.000 1 12Generic GPS 63 10 40 0.000 0 12Alcatel-Lucent RRH2x50-08 137 317 5,957 0.014 19 393Alcatel-Lucent 1900 MHz 4X45 RRH 137 180 3,378 0.008 11 223Alcatel-Lucent TD-RRH8x20-25 w/ Solar Shield 137 210 3,941 0.009 13 260RFS APXVTM14-ALU-I20 137 169 3,164 0.007 10 209Commscope NNVV-65B-R4 137 232 4,358 0.010 14 288Powerwave Allgon LGP21401 128 85 1,386 0.003 4 105Raycap DC6-48-60-18-8F 128 60 983 0.002 3 74Ericsson Radio 8843 - B2 + B66A 128 216 3,534 0.008 11 267Ericsson RRUS 4478 B14 128 180 2,944 0.007 9 223Ericsson RRUS 4449 B5, B12 128 213 3,490 0.008 11 264Allgon 7770.00 128 105 1,720 0.004 6 130Generic Mount Reinforcement 128 200 3,277 0.008 10 248Generic Mount Reinforcement 116 400 5,382 0.012 17 496CCI DMP65R-BU8D 128 287 4,704 0.011 15 356CCI OPA65R-BU8D 128 230 3,760 0.009 12 284Ericsson Radio 4449 B71 B85A 117 225 3,080 0.007 10 279Ericsson 4460 BAND 2/25 117 327 4,476 0.010 14 405Commscope VV-65A-R1 117 71 977 0.002 3 88Ericsson AIR 6419 B41 117 250 3,421 0.008 11 310RFS APXVAARR24_43-U-NA20 117 384 5,252 0.012 17 476Raycap RDIDC-9181-PF-48 105 22 241 0.000 1 27Fujitsu TA08025-B604 105 192 2,113 0.005 7 238Fujitsu TA08025-B605 105 225 2,481 0.006 8 279Commscope FFVV-65B-R2 105 212 2,342 0.005 7 263Generic Flat Stand-Off 75 188 1,055 0.002 3 232Generic Flat Stand-Off 63 188 744 0.002 2 232

46,855 439,379 1.000 1,406 58,075

0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL)

Segment

Height AboveBase

(ft)Weight

(lb)Wz

(lb-ft) Cvx

HorizontalForce

(lb)

VerticalForce

(lb)

40 145.5 80 1,703 0.004 5 6939 142.5 411 8,347 0.019 27 35438 138.75 211 4,064 0.009 13 18237 137.25 43 804 0.002 3 3736 136 192 3,544 0.008 11 16535 132.5 489 8,593 0.020 27 42134 129 200 3,327 0.008 11 17233 126.5 363 5,808 0.013 19 31232 122.5 617 9,256 0.021 30 53131 118.5 377 5,297 0.012 17 32530 116.5 132 1,788 0.004 6 113

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 11 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Segment

Height AboveBase

(ft)Weight

(lb)Wz

(lb-ft) Cvx

HorizontalForce

(lb)

VerticalForce

(lb)

29 115.5 132 1,765 0.004 6 11428 112.5 671 8,486 0.019 27 57727 107.5 685 7,920 0.018 25 59026 102.5 712 7,480 0.017 24 61325 99.2267 223 2,198 0.005 7 19224 96.7267 894 8,367 0.019 27 77023 94.2683 384 3,410 0.008 11 33022 91.7683 603 5,081 0.012 16 51921 87.5 869 6,653 0.015 21 74820 82.5 887 6,040 0.014 19 76419 77.5 906 5,442 0.012 17 78018 72.5 925 4,860 0.011 16 79617 67.5 943 4,297 0.010 14 81216 64 382 1,567 0.004 5 32915 61.5 580 2,193 0.005 7 49914 57.5 981 3,244 0.007 10 84413 54.04 382 1,115 0.002 4 32812 51.54 1,152 3,059 0.007 10 99111 48.4567 1,170 2,747 0.006 9 1,00710 45.9567 444 938 0.002 3 3829 42.5 1,176 2,125 0.005 7 1,0128 37.5 1,199 1,685 0.004 5 1,0317 32.5 1,221 1,289 0.003 4 1,0516 27.5 1,243 940 0.002 3 1,0705 22.5 1,265 641 0.002 2 1,0894 17.5 1,288 394 0.001 1 1,1083 12.5 1,310 205 0.000 1 1,1272 7.5 1,332 75 0.000 0 1,1461 2.5 1,354 8 0.000 0 1,166Samsung B5/B13 RRH-BR04C 146 211 4,496 0.010 14 181Samsung B2/B66A RRH-BR049 146 253 5,397 0.012 17 218Raycap RC3DC-3315-PF-48 146 64 1,364 0.003 4 55Samsung MT6407-77A 146 245 5,218 0.012 17 211Antel LPA-80080/4CF ___ 146 48 1,023 0.002 3 41Antel LPA-80063/4CF 146 40 853 0.002 3 34Andrew SBNHH-1D65B 146 304 6,484 0.015 21 262Generic Flat Low Profile Platform 146 1,875 39,968 0.091 128 1,614Generic Round Platform with Handrails 137.5 2,500 47,266 0.108 151 2,151Generic Round Platform with Handrails 128 2,500 40,960 0.093 131 2,151Generic Round Platform with Handrails 116 2,500 33,640 0.077 108 2,151Generic Round Platform with Handrails 105 2,500 27,562 0.063 88 2,151Generic GPS 137 10 188 0.000 1 9Generic GPS 63 10 40 0.000 0 9Alcatel-Lucent RRH2x50-08 137 317 5,957 0.014 19 273Alcatel-Lucent 1900 MHz 4X45 RRH 137 180 3,378 0.008 11 155Alcatel-Lucent TD-RRH8x20-25 w/ Solar Shield 137 210 3,941 0.009 13 181RFS APXVTM14-ALU-I20 137 169 3,164 0.007 10 145Commscope NNVV-65B-R4 137 232 4,358 0.010 14 200Powerwave Allgon LGP21401 128 85 1,386 0.003 4 73Raycap DC6-48-60-18-8F 128 60 983 0.002 3 52Ericsson Radio 8843 - B2 + B66A 128 216 3,534 0.008 11 186Ericsson RRUS 4478 B14 128 180 2,944 0.007 9 155Ericsson RRUS 4449 B5, B12 128 213 3,490 0.008 11 183Allgon 7770.00 128 105 1,720 0.004 6 90Generic Mount Reinforcement 128 200 3,277 0.008 10 172Generic Mount Reinforcement 116 400 5,382 0.012 17 344CCI DMP65R-BU8D 128 287 4,704 0.011 15 247CCI OPA65R-BU8D 128 230 3,760 0.009 12 197Ericsson Radio 4449 B71 B85A 117 225 3,080 0.007 10 194Ericsson 4460 BAND 2/25 117 327 4,476 0.010 14 281Commscope VV-65A-R1 117 71 977 0.002 3 61Ericsson AIR 6419 B41 117 250 3,421 0.008 11 215RFS APXVAARR24_43-U-NA20 117 384 5,252 0.012 17 330Raycap RDIDC-9181-PF-48 105 22 241 0.000 1 19Fujitsu TA08025-B604 105 192 2,113 0.005 7 165Fujitsu TA08025-B605 105 225 2,481 0.006 8 194Commscope FFVV-65B-R2 105 212 2,342 0.005 7 183Generic Flat Stand-Off 75 188 1,055 0.002 3 161Generic Flat Stand-Off 63 188 744 0.002 2 161

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 12 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Segment

Height AboveBase

(ft)Weight

(lb)Wz

(lb-ft) Cvx

HorizontalForce

(lb)

VerticalForce

(lb)

46,855 439,379 1.000 1,406 40,320

1.2D + 1.0Ev + 1.0Eh Seismic

CALCULATED FORCES

Seg Elev

(ft)

PuFY (-)(kips)

VuFX (-)(kips)

TuMY

(ft-kips)

MuMZ

(fr-kips)

MuMx

(ft-kips)

ResultantMoment(ft-kips)

PhiPn

(kips)

PhiVn

(kips)

PhiTn

(kips)

PhiMn

(kips)

TotalDeflect

(in)Rotation

(deg) Ratio

0.00 -56.40 -1.41 0.00 -177.40 0.00 177.40 4,227.69 1,130.57 5,527 4,712.55 0.00 0.00 0.055.00 -54.74 -1.42 0.00 -170.35 0.00 170.35 4,176.31 1,107.59 5,304 4,560.00 0.01 -0.01 0.05

10.00 -53.12 -1.43 0.00 -163.25 0.00 163.25 4,123.50 1,084.61 5,087 4,408.26 0.02 -0.02 0.0515.00 -51.52 -1.44 0.00 -156.11 0.00 156.11 4,069.26 1,061.63 4,873 4,257.44 0.05 -0.03 0.0520.00 -49.96 -1.44 0.00 -148.93 0.00 148.93 4,013.58 1,038.65 4,665 4,107.62 0.09 -0.04 0.0525.00 -48.41 -1.45 0.00 -141.71 0.00 141.71 3,956.47 1,015.67 4,461 3,958.90 0.14 -0.05 0.0530.00 -46.90 -1.45 0.00 -134.47 0.00 134.47 3,897.92 992.68 4,261 3,811.39 0.20 -0.07 0.0535.00 -45.42 -1.45 0.00 -127.21 0.00 127.21 3,837.94 969.70 4,066 3,665.19 0.28 -0.08 0.0540.00 -43.96 -1.45 0.00 -119.95 0.00 119.95 3,776.52 946.72 3,876 3,520.38 0.36 -0.09 0.0545.00 -43.41 -1.46 0.00 -112.68 0.00 112.68 3,713.67 923.74 3,690 3,377.07 0.46 -0.10 0.0546.91 -41.96 -1.45 0.00 -109.89 0.00 109.89 3,689.24 914.95 3,620 3,322.65 0.50 -0.10 0.0450.00 -40.53 -1.44 0.00 -105.42 0.00 105.42 3,649.39 900.76 3,509 3,235.36 0.57 -0.11 0.0453.08 -40.06 -1.44 0.00 -100.97 0.00 100.97 2,857.95 750.80 2,925 2,537.94 0.65 -0.12 0.0555.00 -38.84 -1.44 0.00 -98.21 0.00 98.21 2,840.65 743.45 2,868 2,497.68 0.70 -0.12 0.0560.00 -38.12 -1.43 0.00 -91.03 0.00 91.03 2,794.59 724.30 2,722 2,393.44 0.84 -0.14 0.0563.00 -37.40 -1.43 0.00 -86.73 0.00 86.73 2,766.27 712.81 2,636 2,331.31 0.93 -0.15 0.0565.00 -36.23 -1.42 0.00 -83.87 0.00 83.87 2,747.10 705.15 2,580 2,290.09 0.99 -0.15 0.0570.00 -35.09 -1.41 0.00 -76.78 0.00 76.78 2,698.18 686.00 2,442 2,187.75 1.16 -0.17 0.0575.00 -33.73 -1.39 0.00 -69.74 0.00 69.74 2,647.83 666.85 2,307 2,086.52 1.34 -0.18 0.0580.00 -32.63 -1.38 0.00 -62.78 0.00 62.78 2,596.04 647.70 2,177 1,986.48 1.53 -0.19 0.0485.00 -31.55 -1.36 0.00 -55.90 0.00 55.90 2,542.81 628.54 2,050 1,887.74 1.74 -0.21 0.0490.00 -30.80 -1.34 0.00 -49.11 0.00 49.11 2,488.15 609.39 1,927 1,790.40 1.97 -0.22 0.0493.54 -30.33 -1.34 0.00 -44.36 0.00 44.36 2,448.63 595.85 1,842 1,722.45 2.13 -0.23 0.0495.00 -29.22 -1.31 0.00 -42.40 0.00 42.40 2,432.06 590.24 1,808 1,694.56 2.20 -0.23 0.0498.45 -28.94 -1.30 0.00 -37.89 0.00 37.89 1,802.83 469.45 1,429 1,251.05 2.37 -0.24 0.05

100.00 -28.06 -1.28 0.00 -35.88 0.00 35.88 1,791.36 464.71 1,401 1,230.45 2.45 -0.24 0.05105.00 -23.31 -1.13 0.00 -29.49 0.00 29.49 1,753.33 449.39 1,310 1,164.33 2.71 -0.26 0.04110.00 -22.48 -1.10 0.00 -23.86 0.00 23.86 1,713.87 434.07 1,222 1,099.03 2.98 -0.27 0.04115.00 -22.31 -1.09 0.00 -18.36 0.00 18.36 1,672.98 418.74 1,137 1,034.64 3.27 -0.28 0.03116.00 -18.55 -0.95 0.00 -17.27 0.00 17.27 1,664.63 415.68 1,121 1,021.88 3.33 -0.28 0.03117.00 -16.53 -0.87 0.00 -16.32 0.00 16.32 1,656.22 412.62 1,104 1,009.16 3.39 -0.28 0.03120.00 -15.76 -0.83 0.00 -13.72 0.00 13.72 1,630.65 403.42 1,056 971.26 3.56 -0.29 0.02125.00 -15.31 -0.81 0.00 -9.55 0.00 9.55 1,586.89 388.10 977 908.99 3.87 -0.29 0.02128.00 -10.02 -0.56 0.00 -7.11 0.00 7.11 1,559.94 378.91 931 872.20 4.05 -0.30 0.02130.00 -9.41 -0.53 0.00 -5.98 0.00 5.98 1,541.69 372.78 901 847.93 4.18 -0.30 0.01135.00 -9.17 -0.52 0.00 -3.31 0.00 3.31 1,495.06 357.46 829 788.18 4.49 -0.30 0.01137.00 -7.74 -0.44 0.00 -2.27 0.00 2.27 1,476.01 351.33 801 764.66 4.61 -0.30 0.01137.50 -4.38 -0.26 0.00 -2.05 0.00 2.05 1,471.21 349.80 794 758.82 4.65 -0.30 0.01140.00 -3.87 -0.23 0.00 -1.39 0.00 1.39 1,447.00 342.14 759 729.83 4.80 -0.30 0.01145.00 -3.77 -0.23 0.00 -0.23 0.00 0.23 1,383.54 326.82 693 666.26 5.12 -0.30 0.00146.00 0.00 -0.21 0.00 0.00 0.00 0.00 1,370.57 323.76 680 653.76 5.18 -0.30 0.00

0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL)

CALCULATED FORCES

Seg Elev

(ft)

PuFY (-)(kips)

VuFX (-)(kips)

TuMY

(ft-kips)

MuMZ

(fr-kips)

MuMx

(ft-kips)

ResultantMoment(ft-kips)

PhiPn

(kips)

PhiVn

(kips)

PhiTn

(kips)

PhiMn

(kips)

TotalDeflect

(in)Rotation

(deg) Ratio

0.00 -39.15 -1.41 0.00 -173.88 0.00 173.88 4,227.69 1,130.57 5,527 4,712.55 0.00 0.00 0.055.00 -38.01 -1.42 0.00 -166.84 0.00 166.84 4,176.31 1,107.59 5,304 4,560.00 0.01 -0.01 0.05

10.00 -36.88 -1.42 0.00 -159.77 0.00 159.77 4,123.50 1,084.61 5,087 4,408.26 0.02 -0.02 0.0515.00 -35.77 -1.43 0.00 -152.66 0.00 152.66 4,069.26 1,061.63 4,873 4,257.44 0.05 -0.03 0.0520.00 -34.68 -1.43 0.00 -145.53 0.00 145.53 4,013.58 1,038.65 4,665 4,107.62 0.09 -0.04 0.0425.00 -33.61 -1.43 0.00 -138.39 0.00 138.39 3,956.47 1,015.67 4,461 3,958.90 0.14 -0.05 0.0430.00 -32.56 -1.43 0.00 -131.23 0.00 131.23 3,897.92 992.68 4,261 3,811.39 0.20 -0.06 0.04

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 13 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

Seg Elev

(ft)

PuFY (-)(kips)

VuFX (-)(kips)

TuMY

(ft-kips)

MuMZ

(fr-kips)

MuMx

(ft-kips)

ResultantMoment(ft-kips)

PhiPn

(kips)

PhiVn

(kips)

PhiTn

(kips)

PhiMn

(kips)

TotalDeflect

(in)Rotation

(deg) Ratio35.00 -31.53 -1.43 0.00 -124.06 0.00 124.06 3,837.94 969.70 4,066 3,665.19 0.27 -0.08 0.0440.00 -30.52 -1.43 0.00 -116.90 0.00 116.90 3,776.52 946.72 3,876 3,520.38 0.36 -0.09 0.0445.00 -30.14 -1.43 0.00 -109.74 0.00 109.74 3,713.67 923.74 3,690 3,377.07 0.45 -0.10 0.0446.91 -29.13 -1.42 0.00 -107.00 0.00 107.00 3,689.24 914.95 3,620 3,322.65 0.49 -0.10 0.0450.00 -28.14 -1.42 0.00 -102.61 0.00 102.61 3,649.39 900.76 3,509 3,235.36 0.56 -0.11 0.0453.08 -27.81 -1.41 0.00 -98.25 0.00 98.25 2,857.95 750.80 2,925 2,537.94 0.63 -0.12 0.0555.00 -26.96 -1.41 0.00 -95.53 0.00 95.53 2,840.65 743.45 2,868 2,497.68 0.68 -0.12 0.0560.00 -26.47 -1.40 0.00 -88.50 0.00 88.50 2,794.59 724.30 2,722 2,393.44 0.82 -0.14 0.0563.00 -25.97 -1.40 0.00 -84.29 0.00 84.29 2,766.27 712.81 2,636 2,331.31 0.90 -0.14 0.0565.00 -25.15 -1.39 0.00 -81.50 0.00 81.50 2,747.10 705.15 2,580 2,290.09 0.97 -0.15 0.0570.00 -24.36 -1.37 0.00 -74.57 0.00 74.57 2,698.18 686.00 2,442 2,187.75 1.13 -0.16 0.0475.00 -23.42 -1.36 0.00 -67.70 0.00 67.70 2,647.83 666.85 2,307 2,086.52 1.31 -0.18 0.0480.00 -22.65 -1.34 0.00 -60.92 0.00 60.92 2,596.04 647.70 2,177 1,986.48 1.50 -0.19 0.0485.00 -21.91 -1.32 0.00 -54.22 0.00 54.22 2,542.81 628.54 2,050 1,887.74 1.70 -0.20 0.0490.00 -21.39 -1.31 0.00 -47.62 0.00 47.62 2,488.15 609.39 1,927 1,790.40 1.92 -0.21 0.0493.54 -21.06 -1.30 0.00 -43.00 0.00 43.00 2,448.63 595.85 1,842 1,722.45 2.08 -0.22 0.0395.00 -20.29 -1.27 0.00 -41.11 0.00 41.11 2,432.06 590.24 1,808 1,694.56 2.15 -0.23 0.0398.45 -20.09 -1.26 0.00 -36.73 0.00 36.73 1,802.83 469.45 1,429 1,251.05 2.31 -0.23 0.04

100.00 -19.48 -1.24 0.00 -34.78 0.00 34.78 1,791.36 464.71 1,401 1,230.45 2.39 -0.24 0.04105.00 -16.18 -1.09 0.00 -28.58 0.00 28.58 1,753.33 449.39 1,310 1,164.33 2.64 -0.25 0.03110.00 -15.60 -1.06 0.00 -23.13 0.00 23.13 1,713.87 434.07 1,222 1,099.03 2.91 -0.26 0.03115.00 -15.49 -1.06 0.00 -17.80 0.00 17.80 1,672.98 418.74 1,137 1,034.64 3.19 -0.27 0.03116.00 -12.88 -0.92 0.00 -16.74 0.00 16.74 1,664.63 415.68 1,121 1,021.88 3.24 -0.27 0.02117.00 -11.47 -0.84 0.00 -15.83 0.00 15.83 1,656.22 412.62 1,104 1,009.16 3.30 -0.27 0.02120.00 -10.94 -0.81 0.00 -13.31 0.00 13.31 1,630.65 403.42 1,056 971.26 3.47 -0.28 0.02125.00 -10.63 -0.79 0.00 -9.27 0.00 9.27 1,586.89 388.10 977 908.99 3.77 -0.28 0.02128.00 -6.95 -0.55 0.00 -6.90 0.00 6.90 1,559.94 378.91 931 872.20 3.95 -0.29 0.01130.00 -6.53 -0.52 0.00 -5.81 0.00 5.81 1,541.69 372.78 901 847.93 4.07 -0.29 0.01135.00 -6.37 -0.51 0.00 -3.22 0.00 3.22 1,495.06 357.46 829 788.18 4.37 -0.29 0.01137.00 -5.37 -0.43 0.00 -2.21 0.00 2.21 1,476.01 351.33 801 764.66 4.50 -0.29 0.01137.50 -3.04 -0.25 0.00 -1.99 0.00 1.99 1,471.21 349.80 794 758.82 4.53 -0.29 0.01140.00 -2.68 -0.23 0.00 -1.35 0.00 1.35 1,447.00 342.14 759 729.83 4.68 -0.29 0.00145.00 -2.62 -0.22 0.00 -0.22 0.00 0.22 1,383.54 326.82 693 666.26 4.99 -0.29 0.00146.00 0.00 -0.21 0.00 0.00 0.00 0.00 1,370.57 323.76 680 653.76 5.05 -0.29 0.00

ASSET: 411216, CT Chaplin South CT CODE: ANSI/TIA-222-H

CUSTOMER: T-MOBILE ENG NO: 14071468_C3_03

©2007 - 2020 by ATC LLC. All rights reserved. Page 14 of 14 Model Id : 28148 Scenario Id: 208553 5/3/2022 15:08:17

ANALYSIS SUMMARY

Reactions . . Max Usage .

Load Case

ShearFX

(kips)

ShearFZ

(kips)

AxialFY

(kips)

MomentMX

(ft-kips)

MomentMY

(ft-kips)

MomentMZ

(ft-kips)Elev

(ft)Interaction

Ratio

1.2D + 1.0W 27.74 0.00 56.18 0.00 0.00 3064.77 53.08 0.670.9D + 1.0W 27.72 0.00 42.13 0.00 0.00 3016.64 53.08 0.651.2D + 1.0Di + 1.0Wi 7.19 0.00 74.18 0.00 0.00 785.58 53.08 0.191.2D + 1.0Ev + 1.0Eh 1.46 0.00 56.40 0.00 0.00 177.40 53.08 0.050.9D - 1.0Ev + 1.0Eh 1.43 0.00 39.15 0.00 0.00 173.88 53.08 0.051.0D + 1.0W 6.20 0.00 46.85 0.00 0.00 679.02 53.08 0.16

ASSET: CODE: ANSI/TIA-222-H

CUSTOMER: ENG NO: 14071468_C3_03

Task ID: 167152 Page 1 of 2 5/3/2022 15:08:23

BASE PLATE ANALYSIS @ 0 FT

PLATE PARAMETERS (ID# 3478)

Diameter: 69 in

Shape: Round

Thickness: 1.75 in

Grade: A572-60

Yield Strength: 60 ksi

Tensile Strength: 75 ksi

Rod Detail Type: d

Clear Distance 3.375 in

Base Weld Size: 0.125 in

Orientation Offset: - °

Analysis Type: Plastic

Neutral Axis: 270 °

ANCHOR ROD PARAMETERS

Class Arrangement Quantity Diameter(in)

Circle(in) Grade Fy

(ksi)Fu

(ksi)Spacing

(in)Offset

(°)

Original[ID# 8063]

Radial 16 2.25 63 A615-75 75 100 - -

ANCHOR ROD GEOMETRY AND APPLIED LOADS --- ORIGINAL (16) 2.25"ø [ID 8063]

Position Radians X(in)

Y(in)

Moment Arm(in)

Inertia(in4)

Axial Load(k)

Shear Load(k)

1 0.393 29.10 12.06 27.890 2526.992 128.19 1.06

2 0.785 22.27 22.27 21.346 1480.625 128.19 1.95

3 1.178 12.06 29.10 11.552 434.259 128.19 2.55

4 1.571 0.00 31.50 0.000 0.839 128.19 2.76

5 1.963 -12.06 29.10 -11.552 434.258 -114.14 2.55

6 2.356 -22.27 22.27 -21.346 1480.624 -114.14 1.95

7 2.749 -29.10 12.06 -27.890 2526.992 -114.14 1.06

8 3.142 -31.50 0.00 -30.188 2960.411 -114.14 0.00

9 3.534 -29.10 -12.06 -27.890 2526.991 -114.14 1.06

10 3.927 -22.27 -22.27 -21.346 1480.624 -114.14 1.95

11 4.320 -12.06 -29.10 -11.552 434.258 -114.14 2.55

12 4.712 0.00 -31.50 0.000 0.839 128.19 2.76

13 5.105 12.06 -29.10 11.552 434.258 128.19 2.55

14 5.498 22.27 -22.27 21.346 1480.625 128.19 1.95

15 5.890 29.10 -12.06 27.890 2526.991 128.19 1.06

16 6.283 31.50 0.00 30.188 2960.411 128.19 0.00

REACTION DISTRIBUTION

Component ID MomentMu (k-ft)

Axial LoadPu (k)

ShearVu (k) Moment Factor

Pole 54.5"ø x 0.375" (18 Sides) 3064.8 56.18 27.74 1.000

Bolt Group Original (16) 2.25"ø 3064.8 - 27.74 1.000

TOTALS 3064.77 56.18 27.74

411216, CT Chaplin South CT

T-MOBILE

ASSET: CODE: ANSI/TIA-222-H

CUSTOMER: ENG NO: 14071468_C3_03

Task ID: 167152 Page 2 of 2 5/3/2022 15:08:23

COMPONENT PROPERTIES

Component IDGross Area

(in2)Net Area

(in2)Individual Inertia

(in4)Moment of Inertia

(in4)Threads/in

Pole 54.5"ø x 0.375" (18 Sides) 63.4413 - - 23234.51 -

Bolt Group Original (16) 2.25"ø 3.9761 3.2477 0.8393 23690.00 4.5

EXTERNAL BASE PLATE BEND LINE ANALYSIS @ 0 FT

POLE PROPERTIES PLATE PROPERTIES

Flat-to-Flat Diameter: 54.62 in Neutral Axis: 270 °

Point-to-Point Diameter: 55.47 in Bend Line Lower Limit: 5.655 rad

Flat Width: 9.632 in Bend Line Upper Limit: 0.628 rad

Flat Radians: 0.349 rad

Bend LineChord Length

(in)Additional Length

(in)Section Modulus

(in3)Applied Moment

Mu (k-in)Moment Capacity

φMn (k-in)Ratio

Flat 37.733 0.00 28.889 614.0 1560.0 0.394

Corner 36.482 0.00 27.932 427.0 1508.3 0.283

Circumferential 51.481 0.00 39.415 1089.3 2128.4 0.512

PLASTIC ANCHOR ROD ANALYSIS

Class Group Quantity Rod Diameter(in)

Applied Axial LoadPu (k)

Applied Shear LoadVu (k)

Compressive CapacityφPn (k)

Ratio

Original 16 2.25 128.1 2.8 243.6 0.549

411216, CT Chaplin South CT

T-MOBILE

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 1/15

Section 1 - Site Information

Section 2 - Existing Template Images

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

Site ID: CT11508FStatus: FinalVersion: 3Project Type: AnchorApproved: 3/1/2022 4:27:24 PMApproved By: [email protected] Modified: 3/1/2022 4:27:24 PMLast Modified By: [email protected]

Site Name: CT508//Verizon ChaplinSite Class: MonopoleSite Type: Structure Non BuildingPlan Year: 2022Market: CONNECTICUT CTVendor: EricssonLandlord: Verizon Wireless

Latitude: 41.78461418Longitude: -72.13554480Address: 121 Palmer RoadCity, State: Chaplin, CTRegion: NORTHEAST

RAN Template: 67D5D998E ODE+6160 AL Template: 67D5998E_1xAIR+1OP+1QP

Sector Count: 3 Antenna Count: 9 Coax Line Count: 0 TMA Count: 0 RRU Count: 6

----- This section is intentionally blank. -----

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 2/15

Section 3 - Proposed Template Images

67D5998E_1xAIR+1OP+1QP.JPG

Notes:

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 3/15

Section 4 - Siteplan Images

----- This section is intentionally blank. -----

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 4/15

Section 5 - RAN Equipment

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

Existing RAN EquipmentTemplate: 67D94E

Enclosure 1

Enclosure Type RBS 6201 ODE

Baseband DUG20 BB 6630 BB 6630G1900 L2100

L1900L700L600

N600

Hybrid CableSystem Ericsson 6x12 HCS *Select Length & AWG*

Radio RUS02 B2 (x 3 ) RUS02 B2 (x 3 )G1900 L1900

Proposed RAN EquipmentTemplate: 67D5D998E ODE+6160

Enclosure 1 2 3 4

Enclosure Type RBS 6201 ODE Ancillary Equipment (Ericsson) Enclosure 6160 AC V1 B160

Baseband BB 6630 DUG20 BB 6630 RP 6651 RP 6651L2100

L1900

G1900 L700

L600N600

N2500 L2500

Hybrid CableSystem Ericsson 6x12 HCS *Select Length

& AWG*

Ericsson Hybrid Trunk 6/24 4AWG50m

PSU 4813 vR4A (Kit)

Ericsson Hybrid Trunk 6/24 4AWG50m

Transport System CSR IXRe V2 (Gen2)

Remove and return all cabinet radios from existing base station cabinet.

Upgrade 6201 breaker to 125A.

Add (1) Enclosure 6160.

Add (1) iXRe Router to new Enclosure 6160.

Add (1) RP 6651 for N2500 to new Enclosure 6160.

Add (1) RP 6651 for L2500 to new Enclosure 6160.

Add (1) PSU4813 Voltage Booster to new Enclosure 6160.

Add (1) Battery Cabinet B160.

Existing : (1) 6x12,

Remove all Coax,

Add (1) 6X24 HCS terminating at the Enclosure 6160. And (1) 6x24 terminating at 6201. Connect DC for the AIR6419 B41 to the PSU4813 Voltage Booster.

RAN Scope of Work:

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 5/15

Section 6 - A&L Equipment

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

Existing Template: 67D94E_1DP+1OPProposed Template: 67D5998E_1xAIR+1OP+1QP

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 6/15

Sector 1 (Existing) view from behindCoverage Type A - Outdoor Macro

Antenna 1 2 3 4

Antenna Model RFS - APXV18-206517S-C-A20 (Dual)

Empty Antenna Mount (Emptymount)

Empty Antenna Mount (Emptymount)

RFS - APXVAARR24_43-U-NA20 (Octo)

Azimuth 60 60

M. Tilt 0 0

Height 118 118

Ports P1 P2 P3 P4 P5

Active Tech. L1900 G1900 L700

L600

N600

L700

L600

N600

L2100

Dark Tech.

Restricted Tech.

Decomm. Tech.

E. Tilt 2 2 2 2 2

Cables 1-5/8" Coax - 145 ft. (x2) CoaxJumper(x2)

CoaxJumper(x2)

1-5/8"Coax- 145ft.(x2)

TMAs Generic Twin Style 1A - PCS(AtAntenna)

EricssonTwinStyle1BX-KRY112144/2(AtAntenna)

Diplexers /Combiners

Radio Radio4449B71+B85 (AtAntenna)

Radio4415B66A (AtCabinet)

SHARED

Radio4449B71+B85 (AtAntenna)

Sector Equipment

Unconnected Equipment:

Replace LB Dual in Position 4 with (1) LB/MB Octo. Add (1) Radio 4449 B71+B12 to Position 4 for L600 and L700.

Add (1) AWS TMA to Position 4. Connect Coaxial Lines and AWS TMA in Position 4 to Mid-Band Ports of LB/MB Octo. Ensure to cascade all 3 octo rets to 4449 for L21 control

Scope of Work:

*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 7/15

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 8/15

Sector 1 (Proposed) view from behindCoverage Type A - Outdoor Macro

Antenna 1 2 3 4

Antenna Model AIR 6419 B41 (Active Antenna -Massive MIMO)

Commscope_VV-65A-R1 (Quad) Empty Antenna Mount (Emptymount)

RFS - APXVAARR24_43-U-NA20 (Octo)

Azimuth 60 60 60

M. Tilt 0 0 0

Height 118 118 118

Ports P1 P2 P3 P4 P5 P6 P7 P8

Active Tech. L2500 N2500 L2500 N2500 L2100 L1900

G1900

L2100 L1900

G1900

L700

L600

N600

L700

L600

N600

Dark Tech.

Restricted Tech.

Decomm. Tech.

E. Tilt 2 2 2 2

Cables Fiber Jumper(x2)

Fiber Jumper(x2)

Coax Jumper(x2)

Fiber Jumper

Coax Jumper(x2)

Fiber Jumper

CoaxJumper(x2)

FiberJumper

CoaxJumper(x2)

FiberJumper

TMAs

Diplexers /Combiners

Radio Radio 4460B25+B66 (AtAntenna)

Radio4449B71+B85 (AtAntenna)

SHARED Radio 4460

B25+B66 (AtAntenna)

SHARED

Radio4449B71+B85 (AtAntenna)

Sector Equipment

Unconnected Equipment:

There will be Three antennae per sector.

Remove all TMAs.

Remove all diplexers.

Remove all Coaxial Lines.

Replace Antenna APXV18 from Position 1 with (1) AIR6419 B41 for L2500 and N2500.

Install (1) mid-band Quad VV-65A-R1 in Position 2 .

Add (1) Radio 4460 B25+B66 for L2100, L1900 (Both carriers), and GSM to Position 2 at antenna.

Remove Radio 4415 B66A from position 4 at antenna.

Ensure RET control is enabled for all technology layers according to the Design Documents

Scope of Work:

*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32-… 9/15

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

Sector 2 (Existing) view from behindCoverage Type A - Outdoor Macro

Antenna 1 2 3 4

Antenna Model RFS - APXV18-206517S-C-A20 (Dual)

Empty Antenna Mount (Emptymount)

Empty Antenna Mount (Emptymount)

RFS - APXVAARR24_43-U-NA20 (Octo)

Azimuth 180 180

M. Tilt 0 0

Height 118 118

Ports P1 P2 P3 P4 P5

Active Tech. L1900 G1900 L700

L600

N600

L700

L600

N600

L2100

Dark Tech.

Restricted Tech.

Decomm. Tech.

E. Tilt 2 2 2 2 2

Cables 1-5/8" Coax - 145 ft. (x2) CoaxJumper(x2)

CoaxJumper(x2)

1-5/8"Coax- 145ft.(x2)

TMAs Generic Twin Style 1A - PCS(AtAntenna)

EricssonTwinStyle1BX-KRY112144/2(AtAntenna)

Diplexers /Combiners

Radio Radio4449B71+B85 (AtAntenna)

Radio4415B66A (AtCabinet)

SHARED

Radio4449B71+B85 (AtAntenna)

Sector Equipment

Unconnected Equipment:

Replace LB Dual in Position 4 with (1) LB/MB Octo. Add (1) Radio 4449 B71+B12 to Position 4 for L600 and L700.

Add (1) AWS TMA to Position 4. Connect Coaxial Lines and AWS TMA in Position 4 to Mid-Band Ports of LB/MB Octo. Ensure to cascade all 3 octo rets to 4449 for L21 control

Scope of Work:

*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 10/15

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e32… 11/15

Sector 2 (Proposed) view from behindCoverage Type A - Outdoor Macro

Antenna 1 2 3 4

Antenna Model AIR 6419 B41 (Active Antenna -Massive MIMO)

Commscope_VV-65A-R1 (Quad) Empty Antenna Mount (Emptymount)

RFS - APXVAARR24_43-U-NA20 (Octo)

Azimuth 180 180 180

M. Tilt 0 0 0

Height 118 118 118

Ports P1 P2 P3 P4 P5 P6 P7 P8

Active Tech. L2500 N2500 L2500 N2500 L2100 L1900

G1900

L2100 L1900

G1900

L700

L600

N600

L700

L600

N600

Dark Tech.

Restricted Tech.

Decomm. Tech.

E. Tilt 2 2 2 2

Cables Fiber Jumper(x2)

Fiber Jumper(x2)

Coax Jumper(x2)

Fiber Jumper

Coax Jumper(x2)

Fiber Jumper

CoaxJumper(x2)

FiberJumper

CoaxJumper(x2)

FiberJumper

TMAs

Diplexers /Combiners

Radio Radio 4460B25+B66 (AtAntenna)

Radio4449B71+B85 (AtAntenna)

SHARED Radio 4460

B25+B66 (AtAntenna)

SHARED

Radio4449B71+B85 (AtAntenna)

Sector Equipment

Unconnected Equipment:

There will be Three antennae per sector.

Remove all TMAs.

Remove all diplexers.

Remove all Coaxial Lines.

Replace Antenna APXV18 from Position 1 with (1) AIR6419 B41 for L2500 and N2500.

Install (1) mid-band Quad VV-65A-R1 in Position 2 .

Add (1) Radio 4460 B25+B66 for L2100, L1900 (Both carriers), and GSM to Position 2 at antenna.

Remove Radio 4415 B66A from position 4 at antenna.

Ensure RET control is enabled for all technology layers according to the Design Documents

Scope of Work:

*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 12/15

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

Sector 3 (Existing) view from behindCoverage Type A - Outdoor Macro

Antenna 1 2 3 4

Antenna Model RFS - APXV18-206517S-C-A20 (Dual)

Empty Antenna Mount (Emptymount)

Empty Antenna Mount (Emptymount)

RFS - APXVAARR24_43-U-NA20 (Octo)

Azimuth 300 300

M. Tilt 0 0

Height 118 118

Ports P1 P2 P3 P4 P5

Active Tech. L1900 G1900 L700

L600

N600

L700

L600

N600

L2100

Dark Tech.

Restricted Tech.

Decomm. Tech.

E. Tilt 2 2 2 2 2

Cables 1-5/8" Coax - 145 ft. (x2) CoaxJumper(x2)

CoaxJumper(x2)

1-5/8"Coax- 145ft.(x2)

TMAs Generic Twin Style 1A - PCS(AtAntenna)

EricssonTwinStyle1BX-KRY112144/2(AtAntenna)

Diplexers /Combiners

Radio Radio4449B71+B85 (AtAntenna)

Radio4415B66A (AtCabinet)

SHARED

Radio4449B71+B85 (AtAntenna)

Sector Equipment

Unconnected Equipment:

Replace LB Dual in Position 4 with (1) LB/MB Octo. Add (1) Radio 4449 B71+B12 to Position 4 for L600 and L700.

Add (1) AWS TMA to Position 4. Connect Coaxial Lines and AWS TMA in Position 4 to Mid-Band Ports of LB/MB Octo. Ensure to cascade all 3 octo rets to 4449 for L21 control

Scope of Work:

*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 13/15

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 14/15

Sector 3 (Proposed) view from behindCoverage Type A - Outdoor Macro

Antenna 1 2 3 4

Antenna Model AIR 6419 B41 (Active Antenna -Massive MIMO)

Commscope_VV-65A-R1 (Quad) Empty Antenna Mount (Emptymount)

RFS - APXVAARR24_43-U-NA20 (Octo)

Azimuth 300 300 300

M. Tilt 0 0 0

Height 118 118 118

Ports P1 P2 P3 P4 P5 P6 P7 P8

Active Tech. L2500 N2500 L2500 N2500 L2100 L1900

G1900

L2100 L1900

G1900

L700

L600

N600

L700

L600

N600

Dark Tech.

Restricted Tech.

Decomm. Tech.

E. Tilt 2 2 2 2

Cables Fiber Jumper(x2)

Fiber Jumper(x2)

Coax Jumper(x2)

Fiber Jumper

Coax Jumper(x2)

Fiber Jumper

CoaxJumper(x2)

FiberJumper

CoaxJumper(x2)

FiberJumper

TMAs

Diplexers /Combiners

Radio Radio 4460B25+B66 (AtAntenna)

Radio4449B71+B85 (AtAntenna)

SHARED Radio 4460

B25+B66 (AtAntenna)

SHARED

Radio4449B71+B85 (AtAntenna)

Sector Equipment

Unconnected Equipment:

There will be Three antennae per sector.

Remove all TMAs.

Remove all diplexers.

Remove all Coaxial Lines.

Replace Antenna APXV18 from Position 1 with (1) AIR6419 B41 for L2500 and N2500.

Install (1) mid-band Quad VV-65A-R1 in Position 2 .

Add (1) Radio 4460 B25+B66 for L2100, L1900 (Both carriers), and GSM to Position 2 at antenna.

Remove Radio 4415 B66A from position 4 at antenna.

Ensure RET control is enabled for all technology layers according to the Design Documents

Scope of Work:

*A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword.

3/2/22, 9:13 AM CT11508F_Anchor_3_2022-03-02

https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/92725a42-3579-48bf-a645-6276dcc659d2?layoutId=7603ef58-db33-4e3… 15/15

Section 7 - Power Systems Equipment

RAN Template:67D5D998E ODE+6160

A&L Template:67D5998E_1xAIR+1OP+1QP

CT11508F_Anchor_3Print Name: Preliminary (RFDS_For_Scoping)

PORs: Anchor_Phase 3

Existing Power Systems Equipment----- This section is intentionally blank. -----

Proposed Power Systems EquipmentEnclosure 1

Enclosure Type Enclosure 6160 AC V1

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

RADIO FREQUENCY EMISSIONS ANALYSIS REPORT

EVALUATION OF HUMAN EXPOSURE POTENTIAL

TO NON-IONIZING EMISSIONS

T-Mobile Existing Facility

Site ID: CT11508F

CT508//Verizon Chaplin

123 Palmer Road

Chaplin, Connecticut 06235

May 25, 2022

EBI Project Number: 6222003373

Site Compliance Summary

Compliance Status: COMPLIANT

Site total MPE% of FCC general population

allowable limit:

29.14%

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

May 25, 2022

T-Mobile Attn: Jason Overbey, RF Manager 35 Griffin Road South Bloomfield, Connecticut 06002

Emissions Analysis for Site: CT11508F - CT508//Verizon Chaplin

EBI Consulting was directed to analyze the proposed T-Mobile facility located at 123 Palmer Road in Chaplin, Connecticut for the purpose of determining whether the emissions from the Proposed T-Mobile Antenna Installation located on this property are within specified federal limits.

All information used in this report was analyzed as a percentage of current Maximum Permissible Exposure (% MPE) as listed in the FCC OET Bulletin 65 Edition 97-01and ANSI/IEEE Std C95.1. The FCC regulates Maximum Permissible Exposure in units of microwatts per square centimeter (µW/cm2). The number of µW/cm2 calculated at each sample point is called the power density. The exposure limit for power density varies depending upon the frequencies being utilized. Wireless Carriers and Paging Services use different frequency bands each with different exposure limits; therefore, it is necessary to report results and limits in terms of percent MPE rather than power density.

All results were compared to the FCC (Federal Communications Commission) radio frequency exposure rules, 47 CFR 1.1307(b)(1) – (b)(3), to determine compliance with the Maximum Permissible Exposure (MPE) limits for General Population/Uncontrolled environments as defined below.

General population/uncontrolled exposure limits apply to situations in which the general population may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Therefore, members of the general population would always be considered under this category when exposure is not employment related, for example, in the case of a telecommunications tower that exposes persons in a nearby residential area.

Public exposure to radio frequencies is regulated and enforced in units of microwatts per square centimeter (μW/cm2). The general population exposure limits for the 600 MHz and 700 MHz frequency bands are approximately 400 μW/cm2 and 467 μW/cm2, respectively. The general population exposure limit for the 1900 MHz (PCS), 2100 MHz (AWS) and 11 GHz frequency bands is 1000 μW/cm2. Because each carrier will be using different frequency bands, and each frequency band has different exposure limits, it is necessary to report percent of MPE rather than power density.

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

Occupational/controlled exposure limits apply to situations in which persons are exposed as a consequence of their employment and in which those persons who are exposed have been made fully aware of the potential for exposure and can exercise control over their exposure. Occupational/controlled exposure limits also apply where exposure is of a transient nature as a result of incidental passage through a location where exposure levels may be above general population/uncontrolled limits (see below), as long as the exposed person has been made fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means.

Additional details can be found in FCC OET 65.

CALCULATIONS

Calculations were done for the proposed T-Mobile Wireless antenna facility located at 123 Palmer Road in Chaplin, Connecticut using the equipment information listed below. All calculations were performed per the specifications under FCC OET 65. Since T-Mobile is proposing highly focused directional panel antennas, which project most of the emitted energy out toward the horizon, all calculations were performed assuming a lobe representing the maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was focused at the base of the tower. For this report, the sample point is the top of a 6-foot person standing at the base of the tower.

For all calculations, all equipment was calculated using the following assumptions:

1) 2 LTE channels (600 MHz Band) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel.

2) 1 NR channel (600 MHz Band) was considered for each sector of the proposed installation. This Channel has a transmit power of 80 Watts.

3) 2 LTE channels (700 MHz Band) were considered for each sector of the proposed installation.

These Channels have a transmit power of 30 Watts per Channel.

4) 4 GSM channels (PCS Band - 1900 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel.

5) 2 LTE channels (PCS Band - 1900 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 60 Watts per Channel.

6) 2 LTE channels (AWS Band – 2100 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 60 Watts per Channel.

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

7) 1 LTE Traffic channel (LTE 1C and 2C BRS Band - 2500 MHz) was considered for each sector of the proposed installation. This Channel has a transmit power of 60 Watts.

8) 1 LTE Broadcast channel (LTE 1C and 2C BRS Band - 2500 MHz) was considered for each

sector of the proposed installation. This Channel has a transmit power of 20 Watts. 9) 1 NR Traffic channel (BRS Band - 2500 MHz) was considered for each sector of the proposed

installation. This Channel has a transmit power of 120 Watts. 10) 1 NR Broadcast channel (BRS Band - 2500 MHz) was considered for each sector of the

proposed installation. This Channel has a transmit power of 40 Watts.

11) All radios at the proposed installation were considered to be running at full power and were uncombined in their RF transmissions paths per carrier prescribed configuration. Per FCC OET Bulletin No. 65 - Edition 97-01 recommendations to achieve the maximum anticipated value at each sample point, all power levels emitting from the proposed antenna installation are increased by a factor of 2.56 to account for possible in-phase reflections from the surrounding environment. This is rarely the case, and if so, is never continuous.

12) For the following calculations, the sample point was the top of a 6-foot person standing at the base of the tower. The maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was used in this direction. This value is a very conservative estimate as gain reductions for these particular antennas are typically much higher in this direction.

13) The antennas used in this modeling are the Ericsson AIR 6419 for the 2500 MHz / 2500 MHz

/ 2500 MHz / 2500 MHz channel(s), the Commscope VV-65A-R1 for the 1900 MHz / 1900 MHz / 2100 MHz channel(s), the RFS APXVAARR24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz channel(s) in Sector A, the Ericsson AIR 6419 for the 2500 MHz / 2500 MHz / 2500 MHz / 2500 MHz channel(s), the Commscope VV-65A-R1 for the 1900 MHz / 1900 MHz / 2100 MHz channel(s), the RFS APXVAARR24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz channel(s) in Sector B, the Ericsson AIR 6419 for the 2500 MHz / 2500 MHz / 2500 MHz / 2500 MHz channel(s), the Commscope VV-65A-R1 for the 1900 MHz / 1900 MHz / 2100 MHz channel(s), the RFS APXVAARR24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz channel(s) in Sector C. This is based on feedback from the carrier with regard to anticipated antenna selection. All Antenna gain values and associated transmit power levels are shown in the Site Inventory and Power Data table below. The maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was used for all

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

calculations. This value is a very conservative estimate as gain reductions for these particular antennas are typically much higher in this direction.

14) The antenna mounting height centerline of the proposed antennas is 117 feet above ground level (AGL).

15) Emissions values for additional carriers were taken from the Connecticut Siting Council active database. Values in this database are provided by the individual carriers themselves.

16) All calculations were done with respect to uncontrolled / general population threshold limits.

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

T-Mobile Site Inventory and Power Data

Sector: A Sector: B Sector: C Antenna #: 1 Antenna #: 1 Antenna #: 1

Make / Model: Ericsson AIR 6419 Make / Model: Ericsson AIR 6419 Make / Model: Ericsson AIR 6419

Frequency Bands: 2500 MHz / 2500 MHz / 2500 MHz /

2500 MHz Frequency Bands:

2500 MHz / 2500 MHz / 2500 MHz /

2500 MHz Frequency Bands:

2500 MHz / 2500 MHz / 2500 MHz /

2500 MHz

Gain: 22.05 dBd / 15.55 dBd / 22.05 dBd /

15.55 dBd Gain:

22.05 dBd / 15.55 dBd / 22.05 dBd /

15.55 dBd Gain:

22.05 dBd / 15.55 dBd / 22.05 dBd /

15.55 dBd Height (AGL): 117 feet Height (AGL): 117 feet Height (AGL): 117 feet

Channel Count: 4 Channel Count: 4 Channel Count: 4 Total TX Power (W): 240.00 Watts Total TX Power (W): 240.00 Watts Total TX Power (W): 240.00 Watts

ERP (W): 31,011.95 ERP (W): 31,011.95 ERP (W): 31,011.95 Antenna A1 MPE %: 9.05% Antenna B1 MPE %: 9.05% Antenna C1 MPE %: 9.05%

Antenna #: 2 Antenna #: 2 Antenna #: 2

Make / Model: Commscope VV-65A-R1 Make / Model: Commscope VV-65A-

R1 Make / Model: Commscope VV-65A-R1

Frequency Bands: 1900 MHz / 1900 MHz / 2100 MHz

Frequency Bands: 1900 MHz / 1900 MHz / 2100 MHz

Frequency Bands: 1900 MHz / 1900 MHz / 2100 MHz

Gain: 15.55 dBd / 15.55 dBd / 16.05 dBd Gain: 15.55 dBd / 15.55

dBd / 16.05 dBd Gain: 15.55 dBd / 15.55 dBd / 16.05 dBd

Height (AGL): 117 feet Height (AGL): 117 feet Height (AGL): 117 feet Channel Count: 8 Channel Count: 8 Channel Count: 8

Total TX Power (W): 360.00 Watts Total TX Power (W): 360.00 Watts Total TX Power (W): 360.00 Watts ERP (W): 13,446.73 ERP (W): 13,446.73 ERP (W): 13,446.73

Antenna A2 MPE %: 3.92% Antenna B2 MPE %: 3.92% Antenna C2 MPE %: 3.92% Antenna #: 3 Antenna #: 3 Antenna #: 3

Make / Model: RFS

APXVAARR24_43-U-NA20

Make / Model: RFS

APXVAARR24_43-U-NA20

Make / Model: RFS

APXVAARR24_43-U-NA20

Frequency Bands: 600 MHz / 600 MHz /

700 MHz Frequency Bands:

600 MHz / 600 MHz / 700 MHz

Frequency Bands: 600 MHz / 600 MHz /

700 MHz

Gain: 12.95 dBd / 12.95 dBd / 13.35 dBd Gain: 12.95 dBd / 12.95 dBd

/ 13.35 dBd Gain: 12.95 dBd / 12.95 dBd / 13.35 dBd

Height (AGL): 117 feet Height (AGL): 117 feet Height (AGL): 117 feet Channel Count: 5 Channel Count: 5 Channel Count: 5

Total TX Power (W): 200.00 Watts Total TX Power (W): 200.00 Watts Total TX Power (W): 200.00 Watts ERP (W): 4,059.02 ERP (W): 4,059.02 ERP (W): 4,059.02

Antenna A3 MPE %: 2.83% Antenna B3 MPE %: 2.83% Antenna C3 MPE %: 2.83%

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

Site Composite MPE % Carrier MPE %

T-Mobile (Max at Sector A): 15.80% Verizon 4.16% AT&T 5.97% Sprint 3.21%

Site Total MPE % : 29.14%

T-Mobile MPE % Per Sector

T-Mobile Sector A Total: 15.80% T-Mobile Sector B Total: 15.80% T-Mobile Sector C Total: 15.80%

Site Total MPE % : 29.14%

• NOTE: Totals may vary by approximately 0.01% due to summation of remainders in calculations.

T-Mobile Maximum MPE Power Values (Sector A)

T-Mobile Frequency Band / Technology (Sector A)

# Channels

Watts ERP (Per

Channel)

Height (feet)

Total Power Density

(µW/cm²)

Frequency (MHz)

Allowable MPE (µW/cm²)

Calculated % MPE

T-Mobile 2500 MHz LTE 1C & 2C Traffic

1 9619.47 117.0 28.07 2500 MHz LTE 1C & 2C

Traffic 1000 2.81%

T-Mobile 2500 MHz LTE 1C & 2C Broadcast

1 717.84 117.0 2.09 2500 MHz LTE 1C & 2C

Broadcast 1000 0.21%

T-Mobile 2500 MHz NR Traffic 1 19238.94 117.0 56.14 2500 MHz NR Traffic 1000 5.61%

T-Mobile 2500 MHz NR Broadcast 1 1435.69 117.0 4.19 2500 MHz NR

Broadcast 1000 0.42%

T-Mobile 1900 MHz GSM 4 1076.77 117.0 12.57 1900 MHz GSM 1000 1.26%

T-Mobile 1900 MHz LTE 2 2153.53 117.0 12.57 1900 MHz LTE 1000 1.26%

T-Mobile 2100 MHz LTE 2 2416.30 117.0 14.10 2100 MHz LTE 1000 1.41%

T-Mobile 600 MHz LTE 2 591.73 117.0 3.45 600 MHz LTE 400 0.86%

T-Mobile 600 MHz NR 1 1577.94 117.0 4.60 600 MHz NR 400 1.15%

T-Mobile 700 MHz LTE 2 648.82 117.0 3.79 700 MHz LTE 467 0.81%

Total: 15.80%

                  EBI Consulting 

                                                             environmental | engineering | due diligence    

21 B Street, Burlington, MA 01803      .         Tel: (781) 273.2500       .        Fax:  (781) 273.3311 

 

Summary

All calculations performed for this analysis yielded results that were within the allowable limits for general population exposure to RF Emissions.

The anticipated maximum composite contributions from the T-Mobile facility as well as the site composite emissions value with regards to compliance with FCC’s allowable limits for general population exposure to RF Emissions are shown here:

T-Mobile Sector Power Density Value (%) Sector A: 15.80% Sector B: 15.80% Sector C: 15.80%

T-Mobile Maximum MPE % (Sector A):

15.80%

Site Total: 29.14%

Site Compliance Status: COMPLIANT

The anticipated composite MPE value for this site assuming all carriers present is 29.14% of the allowable FCC established general population limit sampled at the ground level. This is based upon values listed in the Connecticut Siting Council database for existing carrier emissions.

FCC guidelines state that if a site is found to be out of compliance (over allowable thresholds), that carriers over a 5% contribution to the composite value will require measures to bring the site into compliance. For this facility, the composite values calculated were well within the allowable 100% threshold standard per the federal government.