Indian Bank, Zonal Office, Ahmedabad invites quotations for AMC (Annual Maintenance Contract) of Fire Alarm System, Burglar Alarm System and Portable/Modular Fire extinguisher already installed in our
branches and offices.
You are requested to submit the same in a sealed envelope super scribing as "QUOTATION FOR AMC
OF SYSTEM as per attached format.
Please Note that:
(i) Quotation may be dropped in the box kept at Zonal Office, Indian Bank, Rudra Arcade, Second Floor, Helmet Circle, Memnagar, Ahmedabad - 09.
(i) Last date for submission of quotation is 28 Oct 2020.(ii) Award of contract will be with effect from 01.11.2020 for one year.(iv) Bids will be opened on 29.10.2020 at 03.00 PM by the tender opening committee in front of the bidders
who wished to be present during tender opening.(iv) The firm submitting bids must have official set up in Gujarat state.
(v) The firm must have the past experience of above systems in banking sector, documentary proof i.e.
Purchase Order/Service Order shall be submitted along with the bids.
(iv) Bank has the right to amend/postpone/cancellation of the bidding process.(v)All entries in the bid form should be legible and filled correctly. If the space for furnishing information is insufficient, a separate sheet duly signed by the authorized signatory may be attached.
Date: 07.10.2020
MAINTENANCE SCHEDULE FIRE ALARM SYSTEM& BURGLAR ALARM SYSTEM
1. Terms & Conditions for COMPREHENSIVE AMC:
The firm will maintain all the Fire Alarm System already installed in our branches under the Zone on
quarterly basis at branch location.
The firm will repair and/or replace the faulty parts without claiming any extra charges.
Faulty parts are inclusive of Alarm Panel, Battery, Sensors, Hooters etc.
2. Above comprehensive AMC will NOT include:
Relocation of Alarm System in full or in part.
Replacing or change of any working part (Panel/ Battery/Sensors, etc.) as per Bank's requirement.
3. Terms & Conditions for NON-COMPREHENSIVE AMC.
The firm will carry out the Preventive Maintenance of the system. All small and minor parts to be repaired/replaced without claiming extra charges (Major parts such
as Controi Panel, Sensors, Hooters, Battery are excluded)
Four visits in an interval of 90days are mandatory.
4. Above AMC will be for a period of one year from 01.11.2020 to 31.10.2021.
5. All break downs/faults in systems will be attended immediately within 48 hours and NO Extra
6. AMC of Alarm Systems those are under warranty period will not be covered in above AMC.
7. In casea system is required to be taken to the workshop for major repair, a spare service unit to be
payment will be made for such break down calls.
provided and installed and should function until the original unit is replaced.
8. The AMC will be valid for one year. Based on market rate of products, the rate will be reviewed by
the bank and if both parties agree on same then the contract can be extended for further period of
another year or more.
9 The firm should have adequate technician and well equipped service center in Ahmedabad and/or other cities of Gujarat to attend breakdown calls in shortest possible time, the addresses of the service center provided by the firm will be verified by the Bank.
10. If the services provided by the firm is found to be unsatisfactory or if at any point of time during the
contract it is found that the information provided by firm is false, the Bank reserves the right to
terminate the contract.
QuOTATION FOR COMPREHENSIVE/NON-cOMPREHENSIVE AMC OF FIRE ALARM SYSTEM & BURGLAR ALARMSYSTEM AND RATE CHART OF EQUIPMENTS
Basic Price Cost including
taxes, service
charge,transportation
charge,(excluding GST)
Sl.
No.
Item description Taxes(Otherthan
GST, if
any)
Qty.
2 Zone Fire Alarm Control Panel with auto dialer Make- Agni
4 Zone Fire Alarm Control Panel with
auto dialer Make- Agni 4 Zone Burglar Alarm Control Panel with
auto dialer, Make-Securico6 Zone Burglar Alarm Control Panel with
auto dialer,Make- Securico 12 V Rechargeable BatteryOptical Smoke Detector Heat detectorExternalHooterPanicSwitch
1.
2.
3.
4.
5.
6.
7.
8
9.
10. MagneticSensor 11. PIR Sensor
12. Response Indicator 13. Manual Call Point
14.
1
PER
METER
PER
METER
Cable
15. PVC Conduit pipe
16. Installation Charges, if any
17. Yearly Comprehensive AMC charges for 1 yr
Existing 2/4 Zone Fire Alarm System system already installed in our
Branches/Offices Yearly Non-Comprehensive AMC
charges for Existing 2/4 Zone Fire Alarm System system already installed in our
Branches/offices Buy Back Price for 2 Zone Fire Alarm
Control Panel
18. 1Yr
19. 1
20. Buy Back Price for 4 Zone Fire Alarm
Control Panel
Place:
Date:
Signature of authorized signatory With Seal
MAINTENANCE SCHEDULE FIRE EXTINGUISHERS
TheAMC Will be Non-Comprehensive: (A) Periodicity of Refiling/Testing of Existing and New Fire ExtinguisherS
| Type of extinguisher 01
02 ABC type fire extinguisher 03
04 Automatic Modular type fire extinguisherNote:- a. Initial weight should be taken while installation/ after refilling & recorded in presence of
Branch staff b. After every two Year, examine the gas mass/ weight of CO2 fire extinguisher. If there is loss of more than 10% of Original weight, then it should be recharged.
Sr. Periodicity 02 Years
03 Years
03-05 Years 05 Years
Dry Chemical Powder (DCP) BC type extinguisher
CO2 type fire extinguisher
(B) guidelines issued in BIS 2190:2010.
Refilling and Maintenance work: Maintenance of fire extinguisher should be carried out as per
All fire extinguishers must be discharged/ emptied before refilling of fire extinguishers. The demonstration of fire extinguishers will be given to staff members of branches and offices also Replacement of old gas catridge and extinguishing media of the fire extinguisher. All fire extinguishers and refills and spare parts must confirm to performance and construction specifications as laid down IS 15683:2006 as amended from time to time by BIS. Proper cleaning of interior and exterior of fire extinguisher, polish the painted portion with wax polish, the brass/gun metal parts with metal polish, chromium plated parts with silver polish and plastic components to be thoroughly washed with soap solution and sun dried. Record of maintenance, inspection and testing of all fire extinguishers should be handed over to concurred office/branch.
Checking of nozzles, port hole, vent hole, cap assembly, syphon tube, safety pin/clip, discharge pipe etc.
Checking wall bracket/ fire stand of fire extinguishers
Checking coloring of fire extinguisher, if required then take a prior approval for same by zonalsecurity office/Branch. After refilling paste inspection card to the body of the extinguishers indicating the serialnumber, date of refilling, next due date for refilling, due date for hydraulic testing etc. Ensure that all joints are fully tightened and nozzle, vent hole etc. are free of dust/dirt. Operating instructions of fire extinguishers are legible and facing outward and in good visiblecondition.
Checking of pressure gauge reading or indicator, it should be in operating range only.Hydraulic Pressure test, wherever due should be carried out in conformity with the procedure and periodic laid down in BIS 2190:2010. If fire extinguisher are fails in Hydraulic testing then it will be replaced by new one after getting approval by Zonal Office.
(i) (ii)
iv
(v
vi)
(vii
(vii)
(ix)
x) xi)
(xii) xiii)
QuOTATION FOR AMC (NON-COMPREHENSIVE) OF PORTABLE/MODULAR FIRE EXTINGUISHERS AND RATE CHART OF EQUIPMENTS
Qty Cost including taxes, service charge,
transportation charge, installation cost if any
(excluding GST)
Item description capacity SI.
No.
| 2 kg 1 ABC Mono Ammonium Phosphate base
powder (manual) ABC Mono Ammonium Phosphate base
powder (manual) ABC Mono Ammonium Phosphate base 6 kg
powder (manual) ABC Mono Ammonium Phosphate base 5 Kg
powder (Automatic) DCP (BC) Type CO2 (BC) Type CO2 (BC) Type
1.
2. 4 kg
3. 1
4.
5. 6.
7.
5 Kg 3.2 kg 4.5 Kg
REFILLING AND HYDRAULIC PRESSURE TESTING
1
Extinguisher Type Capacity Qty KG
Job 1 Charges for Refiling of
extinguishers, travelling expenses etc.
refilling work including service
charge, sale tax, octroi if any or DCP
any government tax etc.
8. fire 2
3.2 KG 4.5 KG
KG
KG
2 KG
4 KG
6 KG 2 KG 3.2 KG
| 4.5 KG
KG
5 KG 2 KG
4 KG
6 KG
labour cost, for CO2
5
ABC
1
Charges for Hydraulic Pressure
Testing. 9.
CO2
1
DCP
ABC
1
Job Extinguisher Type Capacity AMC charge per branch Different Yearly Non- Comprehensive
AMC charges per branch 10. CO2, DCP, ABC
capacity BUY BACK
11. Buy back of C02 Type 2 kg/3.2 kg/ 45 kg 12.
13. Buy back of Water Co2 9 Ltr 14. Buy back of ABC Type 4 kg/5 kg 15. Buy Back of Ceasefire, Safex ABC type 1kg/2kg
01 01
01
01
01
Buy back of DCP Type 4 kg /5 kg
Place:Date:
Signature of authorized signatory With Seal