+ All Categories
Transcript
Page 1: Arrowhead APACHE Anti-Siphon Frost Proof Lawn Faucet...Arrowhead APACHE Anti-Siphon Frost Proof Lawn Faucet WARNING: When using a self-closing nozzle, always relieve pressure in the

4 5 5 S E R I E S

Arrowhead APACHE Anti-SiphonFrost Proof Lawn Faucet

WARNING: When using a self-closing nozzle,always relieve pressure in the hose upon watershutoff to activate drainage of faucet.

USAM A D E I N

5147 Alhambra Ave., Los Angeles, CA 90032 323 221-9137, fax 323 221-2579 www.arrowheadbrass.comFor over 70 years, Arrowhead Brass has been known for quality products manufactured and assembled in the USA.

BRASS PRODUCTS, LLC

®

Soft Grip HandleGreen powder coated to help battle corrosionand stainless steel screw

BonnetOne piece with O-ring seal

Acme ThreadIn top of valve away from sandand other impurities in water

“No-Kink”Functional design

Wrench PadsTo keep from abusing body of valve

3/4" L Hard Copper Newly designed solder wellsto pool the 95/5 solder

1/4" L Hard Copper (Internal) Connects stem and seat and insures against deterioration from harsh water chemicals

Health Protection In the event of back siphonage due to a drop ininlet pressure, the vacuum breaker will intake airthrough the ports to break the siphoning action.Any water trying to make its way back to thepotable water supply due to back siphonage orback pressure will be blocked at the point of theback flow preventer/vacuum breaker and drainharmlessly to the ground through the air ports.

The Arrowhead “Apache” hydrant hastaken the best of the old ideas andcombined them in a new way to giveyou a tough, long-lasting and sturdydesign. We use Type L hard copper forour housing and operating rod. Thenewly designed solder wells aroundthe nipple and the base of the bodyassure the pooling of the 95/5 solderfor an absolute solid solder joint. We have taken the historically provenstandard type vacuum breaker andput it back on the hose connectionend of the hydrant. This was notpossible to do in the past and still getthe desired drainage for freeze

Western legend tells of a fierce peoplesurviving on spirit and grit. A resilientclan ready and willing to protect theirown at any cost. These people wereknown as the Apache. You too canstand ready to protect your tribe withthe all new Arrowhead “Apache” Anti-Siphon Frost Proof Lawn Faucet. Thishydrant is built to take the punishmentyou can give it. Built tough to givelong lasting protection against backflow and back pressure. Built solid toprotect your health. Yet built with aconscience to be user friendly. The“Apache” stands ready to protect yourfamily at all times.

protection. Retaining the air vent fromour previous design and using it incombination with a drain has takencare of that problem. After watershutoff, air is allowed to enter thevalve body which in turn will let theremining water in the hydrantevacuate through the drain thusproviding you freeze protection.Finally the “Apache” is designed to beuser friendly. Should the need arise forhydrant repair, all parts may bedismantled with household tools.

1019

IAPMO Listed

ASSE 1019

Pat. #4,909,270

Freeze ProtectionWater from hydrant will drain in a steadygentle stream for approximately 15-20seconds after hydrant is turned off.

Page 2: Arrowhead APACHE Anti-Siphon Frost Proof Lawn Faucet...Arrowhead APACHE Anti-Siphon Frost Proof Lawn Faucet WARNING: When using a self-closing nozzle, always relieve pressure in the

1

2

3 4 5 6

15

16 17 192018

21

WARNING : When using a self-closing nozzle,always relieve pressure in the hose upon watershuto to activate drainage of faucet.

4 5 5 S E R I E S

5147 Alhambra Ave., Los Angeles, CA 90032 323 221-9137, fax 323 221-2579 www.arrowheadbrass.comFor over 70 years, Arrowhead Brass has been known for quality products manufactured and assembled in the USA.

BRASS PRODUCTS, LLC

®

1 Stainless Steel Screw 82 Oval Handle - green 113 O-Ring Bonnet 61CA

4 Bonnet Washer

62F1

metS gniR-O5

RO1gniR-O6

7 Air Vent Plunger 768 Plunger Seat Washer 779 Air Vent Underbody 75

10 Air Vent Cap 7411 Drain Plunger 5412 Drain Plunger Washer 5513 Drain Plunger Spring 5614 Drain Housing 5715 Back Flow prevented Body 58A16 Stainless Steel Spring 58B

C85regnulP7118 Plunger Seal 58D19 Diaphragm 58E20 Brass Disc 58F

21 Stem (length desired)

5rehsaW taeSSeat Washer Screw 6

62

Illus. # Description Part #

IAPMO Listed

ASSE 1019

Pat. #4,909,270

455BFP04 Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 4”

455BFP04LK Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 4”, Loose Key

455BFP06 Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 6”

455BFP06LK Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 6”, Loose Key

455BFP08 Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 8”

455BFP08LK Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 8”, Loose Key

455BFP10 Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 10”

455BFP10LK Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 10”, Loose Key

455BFP12 Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 12”

455BFP12LK Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 12”, Loose Key

455BFP14 Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 14”

455BFP14LK Apache Anti-Siphon Frost Free Hydrant 1/2” FIP or 3/4”MIP x 14”, Loose Key

456BFP04 Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 4”

456BFP04LK Apache Anti-Siphon Fr ost Fr ee Hydrant 1/2” CopperSweat or 1/2” MIP x 4”, Loose Key

456BFP06 Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 6”

456BFP06LK Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 6”, Loose Key

456BFP08 Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 8”

456BFP08LK Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 8”, Loose Key

456BFP10 Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 10”

456BFP10LK Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 10”, Loose Key

456BFP12 Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 12”

456BFP12LK Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 12”, Loose Key

456BFP14 Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 14”

456BFP14LK Apache Anti-Siphon Frost Free Hydrant 1/2” CopperSweat or 1/2” MIP x 14”, Loose Key

459BFP04 Apache Anti-Siphon Frost Free Hydrant PEX x 4”459BFP06 Apache Anti-Siphon Frost Free Hydrant PEX x 6”459BF008 Apache Anti-Siphon Frost Free Hydrant PEX x 8”459BFP10 Apache Anti-Siphon Frost Free Hydrant PEX x 10”459BFP12 Apache Anti-Siphon Frost Free Hydrant PEX x 12”459BFP14 Apache Anti-Siphon Fr ost Fr ee Hydrant PEX x 14”

NOITPIRCSED.ON LEDOMNOITPIRCSED.ON LEDOM

1 2 3 4 5 6

15

16 17 19

2018

11

10

9

8

7

12

13

14

2121

PK1430

PK1440PK1370

or 58BFPCHR

PK1290

PK5004 through PK5014Full stem length minus 4”

Includes 22 & 23

PK5004 through PK5014Full stem length minus 4.25”

PK50_ _ Full Length minus 4.25”

PK1430

PK1440

58BFPCHRPK1370

Graphite Packing (old style) 3


Top Related