8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 1/114
Airbridge BTS CDMA Base Station
V300
Common Alarm Reference
Issue 01
Date 2010-05-10
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 2/114
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any
assistance, please contact our local office or company headquarters.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: [email protected]
Copyright © Huawei Technologies Co., Ltd. 2010. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are the property of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, andrecommendations in this document do not constitute the warranty of any kind, express or implied.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 3/114
Contents
About This Document.....................................................................................................................1
1 Alarm Information.....................................................................................................................1-1
1.1 Alarm Ser ial Number......................................................................................................................................1-2
1.2 Alarm ID.........................................................................................................................................................1-21.3 Alarm Ty pe.....................................................................................................................................................1-2
1.4 Alarm Severity................................................................................................................................................1-2
1.5 Event Type......................................................................................................................................................1-3
2 Common Alarm Reference.......................................................................................................2-1
2.1 ALM-17016 OML Between Board and Main Processing Module Disconnected..........................................2-3
2.2 ALM-17035 Signal Loss at Reception Port of Optical Module......................................................................2-7
2.3 ALM-17038 Optical Port Not In-Position....................................................................................................2-10
2.4 ALM-17048 Version Mismatched Between FPGA Software and CPU Software........................................2-13
2.5 ALM-17082 PA Closed Due to Overtemperature.........................................................................................2-152.6 ALM-17132 Transmission Module Configuration Incompatible.................................................................2-18
2.7 ALM-17133 Contents of Configuration File Incorrect.................................................................................2-22
2.8 ALM-17229 Lightning Arrester of Power Supply Faulty.............................................................................2-24
2.9 ALM-17581 10 M Crystal Oscillator No Output..........................................................................................2-27
2.10 ALM-17586 Number of Locked Satellites Insufficient..............................................................................2-29
2.11 ALM-17587 Satellite Antenna Open-Circuit..............................................................................................2-32
2.12 ALM-17588 Satellite Antenna Short-Circuited..........................................................................................2-35
2.13 ALM-17855 BER of E1/T1 Link Too High................................................................................................2-38
2.14 ALM-17883 Transmission Module IP Address Conflicting.......................................................................2-41
2.15 ALM-18131 DRC Alarm of Private-Line Users.........................................................................................2-42
2.16 ALM-18132 PID Delay Alarm...................................................................................................................2-44
2.17 ALM-18136 DSP Main Clock Abnormal...................................................................................................2-46
2.18 ALM-18138 No Light from Transmission Port of Optical Module............................................................2-47
2.19 ALM-18139 Signal Loss at Reception Port of Optical Module..................................................................2-49
2.20 ALM-18140 Transmission Power Too High at Optical Module................................................................2-52
2.21 ALM-18141 Transmission Power Too Low at Optical Module.................................................................2-54
2.22 ALM-18142 Reception Power Too High at Optical Module......................................................................2-55
2.23 ALM-18143 Reception Power Too Low at Optical Module......................................................................2-58
2.24 ALM-18150 CSM5000 Failure Alarm........................................................................................................2-61
Airbridge BTS CDMA Base Station
Common Alarm Reference Contents
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
i
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 4/114
2.25 ALM-18151 All CSM5000 Failure Alarm..................................................................................................2-64
2.26 ALM-18160 CSM6700 Failure Alarm........................................................................................................2-67
2.27 ALM-18345 DAC Clock of Transmitting Channel Abnormal...................................................................2-69
2.28 ALM-18350 Main and Diversity DDCs Unavailable Synchronously........................................................2-70
2.29 ALM-18356 TRM Blocked Because of the Command..............................................................................2-72
2.30 ALM-18363 Voltage of Power Amplification Power Supply Too High....................................................2-73
2.31 ALM-18364 Voltage of Power Amplification Power Supply Too Low.....................................................2-74
2.32 ALM-18365 TRM Pre-Distortion Capture Over-Time...............................................................................2-77
2.33 ALM-18367 Ratio Between Reference Voltage and Feedback Voltage of Predistortion Module Out of Range
.............................................................................................................................................................................2-78
2.34 ALM-18368 Predistortion Module Feedback Signal Too Small................................................................2-80
2.35 ALM-18376 Communication Link Between Power Amplification Monitoring Board and TRM Disconnected
.............................................................................................................................................................................2-81
2.36 ALM-18392 Power Amplification Gain Abnormal....................................................................................2-84
2.37 ALM-18394 Power Amplification Over-Temperature...............................................................................2-86
2.38 ALM-18395 Power Amplification Closed..................................................................................................2-89
2.39 ALM-18400 Standing Wave Alarm............................................................................................................2-91
2.40 ALM-18525 RF Feedback PLL Unlocked..................................................................................................2-94
2.41 ALM-18526 RF Reverse PLL Unlocked....................................................................................................2-95
2.42 ALM-18527 RF Forward PLL Unlocked....................................................................................................2-97
Contents
Airbridge BTS CDMA Base Station
Common Alarm Reference
ii Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 5/114
Figures
Figure 2-1 Procedure for handling the ALM-17016............................................................................................2-5
Figure 2-2 Pr ocedure for handling the ALM-17035............................................................................................2-9
Figure 2-3 Pr ocedure for handling the ALM-17038..........................................................................................2-12
Figure 2-4 Pr ocedure for handling the ALM-17048..........................................................................................2-15
Figure 2-5 Pr ocedure for handling the ALM-17082..........................................................................................2-17
Figure 2-6 Pr ocedure for handling the ALM-17132..........................................................................................2-20
Figure 2-7 Pr ocedure for handling the ALM-17133 .........................................................................................2-23
Figure 2-8 Pr ocedure for handling the ALM-17229..........................................................................................2-26
Figure 2-9 Pr ocedure for handling the ALM-17581..........................................................................................2-28
Figure 2-10 Procedure for handling the ALM-17586........................................................................................2-31
Figure 2-11 Procedure for handling the ALM-17587........................................................................................2-34
Figure 2-12 Procedure for handling the ALM-17588........................................................................................2-37
Figure 2-13 Procedure for handling the ALM-17855........................................................................................2-40
Figure 2-14 Procedure for handling the ALM-18132........................................................................................2-45Figure 2-15 Procedure for handling the ALM-18138........................................................................................2-49
Figure 2-16 Procedure for handling the ALM-18139........................................................................................2-51
Figure 2-17 Procedure for handling the ALM-18142 .......................................................................................2-57
Figure 2-18 Procedure for handling the ALM-18143 .......................................................................................2-60
Figure 2-19 Procedure for handling the ALM-18150........................................................................................2-63
Figure 2-20 Procedure for handling the ALM-18151........................................................................................2-66
Figure 2-21 Procedure for handling the ALM-18160........................................................................................2-68
Figure 2-22 Procedure for handling the ALM-18350........................................................................................2-71
Figure 2-23 Procedure for handling the ALM-18364........................................................................................2-76
Figure 2-24 Procedure for handling the ALM-18376........................................................................................2-83
Figure 2-25 Procedure for handling the ALM-18392........................................................................................2-85
Figure 2-26 Procedure for handling the ALM-18394........................................................................................2-88
Figure 2-27 Procedure for handling the ALM-18395........................................................................................2-90
Figure 2-28 Procedure for handling the ALM-18400........................................................................................2-93
Airbridge BTS CDMA Base Station
Common Alarm Reference Figures
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iii
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 6/114
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 7/114
Tables
Table 1-1 Description of the alarm types.............................................................................................................1-2
Table 1-2 Description of the alarm severities.......................................................................................................1-2
Table 1-3 Description of the event types..............................................................................................................1-3
Airbridge BTS CDMA Base Station
Common Alarm Reference Tables
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
v
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 8/114
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 9/114
About This Document
Purpose
This document describes the meaning, corrective procedures, and reference information of
CDMA BTS common alarms.
Product Version
The following table lists the product version related to this document.
Product Name Product Version
BTS V300
Intended Audience
This document is intended for:
l System engineers
l Network shifts
Change HistoryInitial release.
Organization
1 Alarm Information
This topic describes the contents and the definitions contained in the alarm information. The
alarm information includes the alarm serial number, alarm ID, alarm type, alarm severity, and
event type.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference About This Document
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 10/114
This topic describes the common alarm information and the handling procedures.
Conventions
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
Indicates a hazard with a high level of risk, which if not
avoided,will result in death or serious injury.
Indicates a hazard with a medium or low level of risk, which
if not avoided, could result in minor or moderate injury.
Indicates a potentially hazardous situation, which if notavoided,could result in equipment damage, data loss,
performance degradation, or unexpected results.
Indicates a tip that may help you solve a problem or save
time.
Provides additional information to emphasize or supplement
important points of the main text.
General Conventions
The general conventions that may be found in this document are defined as follows.
Convention Description
Times New Roman Normal paragraphs are in Times New Roman.
Boldface Names of files, directories, folders, and users are in
boldface. For example, log in as user root.
Italic Book titles are in italics.
Courier New
Examples of information displayed on the screen are inCourier New.
Command Conventions
The command conventions that may be found in this document are defined as follows.
Convention Description
Boldface The keywords of a command line are in boldface.
Italic Command arguments are in italics.
About This Document
Airbridge BTS CDMA Base Station
Common Alarm Reference
2 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 11/114
Convention Description
[ ] Items (keywords or arguments) in brackets [ ] are optional.
{ x | y | ... } Optional items are grouped in braces and separated by
vertical bars. One item is selected.
[ x | y | ... ] Optional items are grouped in brackets and separated by
vertical bars. One item is selected or no item is selected.
{ x | y | ... }* Optional items are grouped in braces and separated by
vertical bars. A minimum of one item or a maximum of all
items can be selected.
[ x | y | ... ]* Optional items are grouped in brackets and separated by
vertical bars. Several items or no item can be selected.
GUI Conventions
The GUI conventions that may be found in this document are defined as follows.
Convention Description
Boldface Buttons, menus, parameters, tabs, window, and dialog titles
are in boldface. For example, click OK .
> Multi-level menus are in boldface and separated by the ">"
signs. For example, choose File > Create > Folder.
Keyboard Operations
The keyboard operations that may be found in this document are defined as follows.
Format Description
Key Press the key. For example, press Enter and press Tab.
Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt
+A means the three keys should be pressed concurrently.
Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means
the two keys should be pressed in turn.
Mouse Operations
The mouse operations that may be found in this document are defined as follows.
Airbridge BTS CDMA Base Station
Common Alarm Reference About This Document
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 12/114
Action Description
Click Select and release the primary mouse button without moving
the pointer.
Double-click Press the primary mouse button twice continuously andquickly without moving the pointer.
Drag Press and hold the primary mouse button and move the
pointer to a certain position.
About This Document
Airbridge BTS CDMA Base Station
Common Alarm Reference
4 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 13/114
1 Alarm Information
About This Chapter
This topic describes the contents and the definitions contained in the alarm information. The
alarm information includes the alarm serial number, alarm ID, alarm type, alarm severity, and
event type.
1.1 Alarm Serial Number
This topic describes the alarm serial number.
1.2 Alarm ID
This topic describes the alarm ID.
1.3 Alarm Ty pe
This topic describes the alarm types: fault alarm and event alarm.
1.4 Alarm Severity
This topic describes the alarm severities: critical, major, minor, and warning.
1.5 Event Ty pe
This topic describes the event types: power system, environment system, signaling system, trunk
system, hardware system, software system, running system, communication system, QoS, and
processing error.
Airbridge BTS CDMA Base Station
Common Alarm Reference 1 Alarm Information
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1-1
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 14/114
1.1 Alarm Serial Number
This topic describes the alarm serial number.
Alarm serial number is an integer ranging from 1 to 999999999. It is used cyclically to identify
alarms. In a numbering cycle, an alarm serial number identifies only one alarm. The alarms of
the same type but with different report sources or report time have different alarm serial numbers.
1.2 Alarm ID
This topic describes the alarm ID.
Alarm ID is an integer ranging from 1 to 32000. An alarm ID identifies only one alarm. The
alarms of the same type but with different report sources or report time have the same alarm IDs
and handling procedures.
1.3 Alarm Type
This topic describes the alarm types: fault alarm and event alarm.
Table 1-1 describes the alarm types.
Table 1-1 Description of the alarm types
Type Description
Fault alarm The fault alarm indicates the status of the equipment. When an alarm isgenerated, the status is set to a value. When the alarm is cleared, the status is
set to another value. The severity of the fault alarm is normally higher than
that of the event alarm. All fault alarms must be cleared.
Event alarm The event alarm indicates that an accidental event occurs when the equipment
is running. It indicates an instant status. Event alarms need not to be cleared
and some event alarms are regularly resent.
1.4 Alarm SeverityThis topic describes the alarm severities: critical, major, minor, and warning.
Table 1-2 describes the alarm severities.
Table 1-2 Description of the alarm severities
Severity Description
Critical The alarm of this severity affects the system services, and you must take
immediate actions. If the equipment or resource cannot be used, you must
restore it immediately. Even if the fault occurs during non-working time, you
also need to take immediate actions.
1 Alarm Information
Airbridge BTS CDMA Base Station
Common Alarm Reference
1-2 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 15/114
Severity Description
Major Alarm of this severity affects the quality of service (QoS) and you must take
immediate actions. If the QoS of the equipment or resource decreases, you
must restore the equipment or resource to recover its capability. You must take
immediate actions during the working time.
Minor Alarm of this severity does not affect the QoS. To avoid the fault with higher
severity, however, you need to take actions in proper time or observe the fault.
Warning Alarm of this severity indicates that errors may exist to affect the service.
Based on different errors, you must take different actions to handle the errors.
1.5 Event Type
This topic describes the event types: power system, environment system, signaling system, trunk
system, hardware system, software system, running system, communication system, QoS, and
processing error.
Table 1-3 describes the event types.
Table 1-3 Description of the event types
Type Description
Power
system
Alarms about the power system
Environme
nt system
Alarms about the environment of equipment room, such as the temperature,
humidity, and door status
Signaling
system
Alarms about the channel associated signaling (SS1) and the common channel
signaling (SS7)
Trunk
system
Alarms about the trunk circuits and the trunk boards
Hardware
system
Alarms about the board equipment such as the clock and the CPU
Software
system
Alarms about the software
Running
system
Alarms generated when the system is running
Communic
ation
system
Alarms about the communication system such as the communication between
the host and the BAM
QoS Alarms about the QoS
Processing
error
Alarms about other exceptions
Airbridge BTS CDMA Base Station
Common Alarm Reference 1 Alarm Information
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1-3
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 16/114
1 Alarm Information
Airbridge BTS CDMA Base Station
Common Alarm Reference
1-4 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 17/114
2 Common Alarm Reference
About This Chapter
This topic describes the common alarm information and the handling procedures.
2.1 ALM-17016 OML Between Board and Main Processing Module Disconnected
2.2 ALM-17035 Signal Loss at Reception Port of Optical Module
2.3 ALM-17038 Optical Port Not In-Position
2.4 ALM-17048 Version Mismatched Between FPGA Software and CPU Software
2.5 ALM-17082 PA Closed Due to Overtemperature
2.6 ALM-17132 Transmission Module Configuration Incompatible
2.7 ALM-17133 Contents of Configuration File Incorrect
2.8 ALM-17229 Lightning Arrester of Power Supply Faulty
2.9 ALM-17581 10 M Crystal Oscillator No Output
2.10 ALM-17586 Number of Locked Satellites Insufficient
2.11 ALM-17587 Satellite Antenna Open-Circuit
2.12 ALM-17588 Satellite Antenna Short-Circuited
2.13 ALM-17855 BER of E1/T1 Link Too High
2.14 ALM-17883 Transmission Module IP Address Conflicting
2.15 ALM-18131 DRC Alarm of Private-Line Users
2.16 ALM-18132 PID Delay Alarm
2.17 ALM-18136 DSP Main Clock Abnormal
2.18 ALM-18138 No Light from Transmission Port of Optical Module
2.19 ALM-18139 Signal Loss at Reception Port of Optical Module
2.20 ALM-18140 Transmission Power Too High at Optical Module
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-1
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 18/114
2.21 ALM-18141 Transmission Power Too Low at Optical Module
2.22 ALM-18142 Reception Power Too High at Optical Module
2.23 ALM-18143 Reception Power Too Low at Optical Module
2.24 ALM-18150 CSM5000 Failure Alarm
2.25 ALM-18151 All CSM5000 Failure Alarm
2.26 ALM-18160 CSM6700 Failure Alarm
2.27 ALM-18345 DAC Clock of Transmitting Channel Abnormal
2.28 ALM-18350 Main and Diversity DDCs Unavailable Synchronously
2.29 ALM-18356 TRM Blocked Because of the Command
2.30 ALM-18363 Voltage of Power Amplification Power Supply Too High
2.31 ALM-18364 Voltage of Power Amplification Power Supply Too Low
2.32 ALM-18365 TRM Pre-Distortion Capture Over-Time
2.33 ALM-18367 Ratio Between Reference Voltage and Feedback Voltage of Predistortion
Module Out of Range
2.34 ALM-18368 Predistortion Module Feedback Signal Too Small
2.35 ALM-18376 Communication Link Between Power Amplification Monitoring Board and
TRM Disconnected
2.36 ALM-18392 Power Amplification Gain Abnormal
2.37 ALM-18394 Power Amplification Over-Temperature
2.38 ALM-18395 Power Amplification Closed
2.39 ALM-18400 Standing Wave Alarm
2.40 ALM-18525 RF Feedback PLL Unlocked
2.41 ALM-18526 RF Reverse PLL Unlocked
2.42 ALM-18527 RF Forward PLL Unlocked
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-2 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 19/114
2.1 ALM-17016 OML Between Board and Main Processing Module Disconnected
Description
The ALM-17016 is reported when the operation and maintenance links (OML) between other
boards and the main processing module are interrupted.
Through the OML, the main processing module performs loading, configuration, maintenance,
and state management on other configured boards of the BTS. When the main processing module
detects that the OML between a board and the main processing module is interrupted, it reports
the alarm.
Through the alarm, you can find in time the interruption of the OML between the board and the
main processing module.
The main processing module of the BBU3606 is the CMPT, and that of other types of BTS is
the BCKM.
Attribute
Alarm ID Alarm Severity Alarm Type
17016 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated
Board ID ID of the board where the alarm is generated
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The impact of the ALM-17016 on the system is as follows:
l The board is unavailable after the alarm is reported.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-3
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 20/114
l The Service Maintenance System cannot operate and maintain the board.
l In the equipment panel of the Service Maintenance System, the board status is in gray
(offline).
System Actions
If the board where the alarm is generated is in position, the board is automatically reset and
restarted.
Possible Causes
The causes of the ALM-17016 are listed as follows:
l The BTS configuration data is incorrect.
l The actual slot number of the board is inconsistent with the configured board slot number.
l
The board is not installed or inserted tightly.l The board is not powered on.
l The board hardware or backplane is faulty.
The CCPM/CECM/HCPM/HECM provides transmission for the RF module. As a result, except
the previous causes, the following may also be the causes:
l The CCPM/CECM/HCPM/HECM is not started.
l The cable between the CCPM/CECM/HCPM/HECM and the RF module is faulty.
l The CCPM/CECM/HCPM/HECM is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-4 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 21/114
Figure 2-1 Procedure for handling the ALM-17016
Procedure
Step 1 Check whether the BTS configuration is correct.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-5
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 22/114
l If the BTS configuration data is wrong, modify the configuration data. Check whether the
alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to
2.
l If the configuration data is correct, go to 2.
Step 2 Check whether the planned slot is configured with a board.
If a board should be configured, configure the board. Check whether the alarm is cleared. If the
alarm is cleared, the procedure ends. If the alarm is not cleared, go to 3.
If the board is configured, go to 3.
Step 3 Check whether the CCPM/CECM/HCPM/HECM is available.
If the RF module is faulty, in the equipment panel of the Service Maintenance System, check
whether the CCPM/CECM/HCPM/HECM is available.
l If it is unavailable, go to 4.
l
If it is available, go to 5.
Step 4 Check whether the CCPM/CECM/HCPM/HECM is started.
View the board status from the equipment panel and check whether the CCPM/CECM/HCPM/
HECM is started.
l If the CCPM/CECM/HCPM/HECM is not started, start it. Check whether the alarm is
cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 5.
l If the board is started, go to 5.
Step 5 Bring the spare parts to the site and replace the faulty parts.
Bring the spare parts to the site and replace the faulty parts. Check whether the alarm is cleared.
If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 6. The spare partsare as follows:
l STDM/CCPM/CECM/HCPM/HECM/main processing module
l Cable
l Optical module
Step 6 Check whether the board is in position and whether the slot position is correct.
l If the board is not in position, insert the board to ensure that it is in the position. Check
whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not
cleared, go to 7.
l If the board is in position and the slot position is correct, go to 7.
Step 7 Check whether the cable is faulty.
If the STDM is faulty, remove and then insert the cable to check whether the cable is faulty.
l If the cable is faulty, replace the cable. Check whether the alarm is cleared. If the alarm is
cleared, the procedure ends. If the alarm is not cleared, go to 8.
l If the cable is operational, perform 8.
Step 8 Replace the faulty board.
To replace the board that reports the alarm, ref er to the BTS Site Maintenance Guide.
----End
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-6 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 23/114
Related Information
None.
2.2 ALM-17035 Signal Loss at Reception Port of OpticalModule
Description
When the optical receiving port of the optical module does not receive signals, the ALM-17035
is reported.
When the reception optical port of the optical module receives signals, the RF module/ODU
connected with the optical port function and the BTS is operational.
Through the alarm, you can find in time the fault at the receiving optical port of the opticalmodule.
Attribute
Alarm ID Alarm Severity Alarm Type
17035 Major Fault
ParametersName Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, HECM,
STDM, and ODU
Board ID ID of the board where the alarm is generatedl CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
l STDM (0)
l CMTR (0-5)
l ODU (0-17)
Subunit type Type of the subunit where the alarm is generated
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-7
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 24/114
Name Meaning
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The services carried by the sector carriers of the RF module that is connected to the optical port
are interrupted.
System Actions
None.
Possible Causes
The causes of ALM-17035 are listed as follows:
l The contact between the receiving port and the fiber is poor or the fiber is damaged.
l The STDM/CMTR/OMTR connected with the optical fiber is not powered on or the optical
module of the STDM/CMTR/OMTR is faulty.
l The ODU connected with the optical fiber is not powered on or the optical module of the
ODU is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-8 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 25/114
Figure 2-2 Procedure for handling the ALM-17035
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-9
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 26/114
Procedure
Step 1 Keep the spare parts ready.
The spare parts are as follows:
l STDM
l Optical module
Step 2 Check whether the fiber is connected to the receiving optical port.
l If the fiber is not connected to the receiving port, connect the fiber and go to 3.
l If the fiber is connected, go to 3.
Step 3 Remove and insert the fiber on the receiving optical port of the optical module.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is
not cleared, go to 4.
Step 4 Replace the optical fibers.
To replace the optical fiber, refer to the BTS Site Maintenance Guide. Check whether the alarm
is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 5.
Step 5 Check whether the ODU is powered on.
l If it is powered off, switch on the power switch. Check whether the alarm is cleared. If the
alarm is cleared, the procedure ends. If the alarm is not cleared, go to 6.
l If it is powered on, go to 6.
Step 6 Replace the ODU.
Step 7 Check whether the STDM/CMTR/OMTR is powered on.
l If it is powered off, switch on the power switch. Check whether the alarm is cleared. If the
alarm is cleared, the procedure ends. If the alarm is not cleared, go to 8.
l If it is powered on, go to 8.
Step 8 Replace the STDM/CMTR/OMTR.
To replace the STDM/CMTR/OMTR that reports the ALM-17035, refer to the BTS Site
Maintenance Guide.
----End
Related Information None.
2.3 ALM-17038 Optical Port Not In-Position
Description
When the small form-factor pluggable (SFP) interface of the specified port is not in position,
the ALM-17038 is reported.
The SFP interface is photoelectricity compatible. In the board, it is an electrical interface socket.The SFP interface transmits high-speed signals through different modules. The SFP interface
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-10 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 27/114
transmits the signals between the CECM/CCPM/HCPM/HECM and the STDM/CMTR. Only
when the SFP interface is normal, the services carried by the RF module are normal, and the
BTS is operational. When the SFP interface is not in position, the ALM-17038 is reported.
Through the alarm, you can find in time the fault in the SFP interface.
Attribute
Alarm ID Alarm Severity Alarm Type
17038 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, HECM,
STDM, and CMTR
Board ID ID of the board where the alarm is generated:
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
l STDM (0)
l CMTR (0-5)
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The services configured in the SFP interface where the alarm is generated cannot be set up.
System Actions
None.
Possible Causes
The causes of the ALM-17038 are as follows:
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-11
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 28/114
l The SFP port is not installed.
l The SFP port is not connected properly.
l The SFP port is faulty.
Workflow
Figure 2-3 Procedure for handling the ALM-17038
Procedure
Step 1 Check the type of the SFP port and keep the spare parts ready.
The spare parts are as follows:
l Optical module
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-12 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 29/114
l Electrical module
Step 2 Check whether the SFP port is installed.
l If the SFP port is not installed, install it. Ensure that the installation is correct, and then go
to 3.l If it is installed, go to 3.
Step 3 Check whether the SFP port is installed correctly and observe the Tx indicator of the port.
l If the indicator is ON, check whether the alarm is cleared. If the alarm is not cleared, go to
4.
l If the indicator is OFF, go to 4.
Step 4 Remove and then insert the SFP port and observe the Tx indicator of the port.
l If the indicator is ON, check whether the alarm is cleared. If the alarm is not cleared, go to
5.
l If the indicator is OFF, go to 5.
Step 5 Replace the SFP port.
----End
Related Information
None.
2.4 ALM-17048 Version Mismatched Between FPGASoftware and CPU Software
Description
The ALM-17048 is reported when the version of the field programmable gate array (FPGA)
software of a board is not compatible with the version of the CPU software.
Only when the version of the board FPGA software matches the version of the CPU software,
the board can work normally. When the board is started, the CPU software automatically checks
the version of the FPGA software. When the CPU software detects that the FPGA softwareversion does not match the version of the CPU software, the ALM-17048 is reported.
Through the alarm, you can find in time the fault in the versions of the board FPGA software
and the CPU sof tware.
Attribute
Alarm ID Alarm Severity Alarm Type
17048 Critical Fault
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-13
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 30/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, HECM,
BCIM, CMPT, and STDM
Board ID ID of the board where the alarm is generated:
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)l HECM (0-5)
l BCIM (0-1)
l CMPT (0-1)
l STDM (0)
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The board where the alarm is generated is unavailable. The board cannot carry the services.
System Actions
None.
Possible Causes
In the board where the alarm is generated, the version of the FPGA software does not match theversion of the CPU software.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-14 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 31/114
Workflow
Figure 2-4 Procedure for handling the ALM-17048
Procedure
Step 1 Check and replace the board software of the BAM.
Check and replace the board software of the BAM based on the FPGA software and CPU
software versions described in the Version Configuration Information.
Step 2 Upgrade the FPGA software and the CPU software of the checked board.
Run the DLD CBTSSW command to upgrade the FPGA software and the CPU software of the
checked board.
----End
Related Information
The related commands are as follows:
DLD CBTSSW
2.5 ALM-17082 PA Closed Due to Overtemperature
Description
If the function of disabling the power amplification due to the BTS overtemperature is enabled,
the power amplification in the RF subrack is disabled when the baseband subrack temperature
exceeds the threshold of the temperature. At this time, the ALM-17082 is reported.
The BCKM/CMPT software monitors the board temperature in the baseband subrack in real
time. When the highest temperature of the board exceeds the threshold, the software disables
the power amplification of the RF subrack and reports the alarm to reduce the cabinet temperatureand protect the baseband modules.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-15
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 32/114
Through the alarm, you can know that the normal operation of the equipment is affected by the
overtemperature of the baseband subrack.
Attribute
Alarm ID Alarm Severity Alarm Type
17082 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: BCKM and CMPT
Board ID ID of the board where the alarm is generated: 0
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The services carried by the BTS are interrupted
System Actions
When the temperature of the baseband subrack is lower than the temperature threshold, the
BCKM software automatically enables the power amplification and reports that the alarm is
cleared.
Possible CausesThe causes of the ALM-17082 are as follows:
l The temperature threshold is set too low.
l The BTS fan is faulty.
l The ambient temperature is too high.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-16 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 33/114
Workflow
Figure 2-5 Procedure for handling the ALM-17082
Procedure
Step 1 Check whether the temperature threshold is reasonable.
Run the DSP CBTSCFG command to check whether the temperature threshold is reasonable.
l If the temperature threshold is unreasonable, reset it. Check whether the alarm is cleared. If
the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 2.
l If the temperature threshold is reasonable, go to 2.
Step 2 Check whether an alarm related to the BTS fan is generated.
Check whether the overtemperature alarm is generated in the fan module of the baseband
subrack.
l
If the alarm is generated, clear the alarm. Check whether the alarm is cleared. If the alarm iscleared, the procedure ends. If the alarm is not cleared, go to 3.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-17
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 34/114
l If the alarm does not exist, go to 4.
Step 3 After the alarm related to the BTS fan is cleared, wait for 30 minutes and then observe the result.
After the alarm related to the BTS fan is cleared for 30 minutes, check whether the ALM-17082
alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 4.
Step 4 Take measures to ensure that the temperature of the equipment room is normal.
----End
Related Information
The related commands are as follows:
DSP CBTSCFG
2.6 ALM-17132 Transmission Module ConfigurationIncompatible
Description
The alarm is reported when the transmission module (BCIM/CMPT) type is inconsistent with
the BTS configuration information.
After the main processing module receives the reset report from the transmission module, it
obtains the type of the transmission module and compares the type with the configuration
information. When the main processing module detects that the type of the transmission moduleis inconsistent with the BTS configuration information, it reports the alarm.
Through the alarm, you can find the fault of the hardware configuration of the transmission
module in time.
Attribute
Alarm ID Alarm Severity Alarm Type
17132 Major Fault/clear
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: BCIM and CMPT
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-18 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 35/114
Name Meaning
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The ALM-17132 has the following impacts on the system:
l The transmission module cannot work.
l
The OML is interrupted.l The services are interrupted.
System Actions
None.
Possible Causes
The causes of the ALM-17132 are as follows:
l The type of the transmission module is incompatible with the link group type.
l The BTS is configured to use the FE cable for transmission, but the BCIM type is
QC52BCIM.
l The board IP address is configured, but the BCIM type is QC52BCIM.
l The board route is configured, but the BCIM type is QC52BCIM.
l The BCIM type is incompatible with the time slot cross configuration information. The
QC54BCIM supports only the time slot cross of number 0 and number 1 links.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-19
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 36/114
Workflow
Figure 2-6 Procedure for handling the ALM-17132
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-20 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 37/114
Procedure
Step 1 Check whether the type of the transmission module is compatible with the link group type.
Check whether the BCIM type is compatible with the link group type.
l The QC52BCIM supports the UNI/IMA/FRAC IMAFRAC links.
l The QC54BCIM supports the PPP and the MLPPP links.
Check whether the BCIM type is compatible with the link group type.
l If they are not compatible, change the configuration information or refer to the BTS Site
Maintenance Guide to replace the board. Check whether the alarm is cleared. If the alarm is
cleared, the procedure ends. If the alarm is not cleared, go to 2.
l If they are compatible, go to 2.
Step 2 Check whether the BTS is configured to use the FE cable for transmission.
Check whether the BTS is configured as the FE mode if the board type is QC52BCIM.
l If the BTS is configured as the FE mode, refer to the BTS Site Maintenance Guide to replacethe board with the QC54BCIM or remove the FE configuration. Observe whether the alarm
is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 3.
l If the BTS is not configured to use the FE cable for transmission, go to 3.
If the board type is not QC52BCIM, go to 5.
Step 3 Check whether the board IP address is configured.
Check whether the board IP address is configured if the board type is QC52BCIM.
l If the IP address is configured, refer to the BTS Site Maintenance Guide to replace the board
or refer to the BTS Data Configuration Guide to reconfigure the BCIM. Observe whether
the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared,
go to 4.
l If the board is not configured with the IP address, go to 4.
If the board type is not QC52BCIM, go to 5.
Step 4 Check whether the board route is configured.
If the board type is QC52BCIM, check whether the board route is configured.
l If it is, refer to the BTS Site Maintenance Guide to replace the board with the QC54BCIM
or remove the routing configuration. Observe whether the alarm is cleared. If the alarm is
cleared, the procedure ends. If the alarm is not cleared, go to 5.
l If the route is not configured, go to 5.
If the board type is not QC52BCIM, go to 5.
Step 5 Change the configuration information or replace the board.
The relation between the type of the transmission module and the time slot cross configuration
is as follows:
l The QC52BCIM supports the timeslot cross configuration.
l The QC54BCIM only supports the external timeslot cross of the number 0 and number 1
links. When the number 1 link type is PPP or MLPPP, you cannot configure the time slot
cross to it.
Change the configuration information or refer to the BTS Site Maintenance Guide to replace the
board.
----End
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-21
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 38/114
Related Information
None.
2.7 ALM-17133 Contents of Configuration File Incorrect
Description
When the BTS configuration file is wrong, the ALM-17133 is reported.
When the BTS is reset, it reads and activates the configuration file in the BAM. Through a
command, the BTS can read, write, or activate the configuration file. If the BTS fails to read,
write, or activate the configuration file, the alarm is reported.
Through the alarm, you can find in time the fault in the contents of the BTS configuration file.
Attribute
Alarm ID Alarm Severity Alarm Type
17133 Major Fault/recovery
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: BCKM and CMPT
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The alarm causes failure to configure the boards and the service data of the BTS. As a result,
the BTS cannot operate properly.
System Actions
The BTS attempts to download and activate the configuration file in the BAM.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-22 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 39/114
Possible Causes
The causes of the ALM-17133 are as follows:
l The FLASH has no configuration file to be activated.
l The BTS fails to read the configuration file.
l The BTS fails to write the configuration file.
l The configuration file is wrong.
Workflow
Figure 2-7 Procedure for handling the ALM-17133
Procedure
Step 1 Reload and activate the configuration file.
Run the DLD CBTSSW command in the Service Maintenance System to reload and activate
the BTS configuration file.
l If the configuration file is activated, check whether the alarm is cleared. If the alarm is cleared,
the procedure ends. If the alarm is not cleared, go to 2.
l If the configuration file is not activated, go to 2.
Step 2 Check the versions.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-23
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 40/114
Check whether the version of the BCKM/CMPT software is consistent with the version of the
configuration file that fails to be activated.
l If the versions are consistent, go to 3.
l If the versions are inconsistent, replace the configuration file in the BAM and perform 1.
Step 3 Check the configuration command.
l If the configuration command is wrong, modify or replace the configuration file.
l If the configuration command is correct, the procedure ends.
----End
Related Information
The related command is as follows:
DLD CBTSSW
2.8 ALM-17229 Lightning Arrester of Power Supply Faulty
Description
The ALM-17229 is reported when the lightning arrester of the power supply is faulty or the
connection between the lightning arrester and the BTS is exceptional.
The lightning arrester of the power supply protects the BTS against lightning strikes.
Through the alarm, you can find in time the fault in the lightning arrester and the connection.
Attribute
Alarm ID Alarm Severity Alarm Type
17229 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: BCKM and CMPT
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-24 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 41/114
Name Meaning
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The impact of the ALM-17229 on the system is as follows:
l The power supply system, boards, and other equipment are damaged during the lightning
strike.
l The services are interrupted during the lightning strike.
System Actions
None.
Possible Causes
The causes of the ALM-17229 are as follows:
l The connection between the lightning arrester and the BTS is exceptional or the connecting
cable is faulty.
l The communication cable that connects to the STDM is interrupted.
l The lightning arrester is faulty.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-25
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 42/114
Workflow
Figure 2-8 Procedure for handling the ALM-17229
Procedure
Step 1 Keep the spare parts ready.Bring the spare parts to the site. The spare parts are as follows:
l lightning arrester
l Cable
Step 2 Connect the test cable to check whether the cable is faulty.
l If the cable is faulty, go to 3.
l If the alarm is cleared, the procedure ends.
Step 3 Remove and then insert the connecting cable.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm isnot cleared, go to 4.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-26 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 43/114
Step 4 Replace the connecting cable.
To replace the connecting cable, refer to the BTS3 Site Maintenance Guide. Check whether the
alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 5.
Step 5 Replace the lightning arrester.
----End
Related Information
None.
2.9 ALM-17581 10 M Crystal Oscillator No Output
Description
The ALM-17581 is reported when the clock module of the BCKM/CMPT cannot detect the
output clock signal of the 10 MHz voltage controlled oscillator.
Through the alarm, you can find in time the fault in the output clock signal of the 10 MHz voltage
controlled oscillator.
Attribute
Alarm ID Alarm Severity Alarm Type
17581 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CLK module of the main
processing module
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated: default subunit type
Subunit ID ID of the subunit where the alarm is generated: default subunit ID
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-27
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 44/114
Impact on the System
When the ID of the board that reports the alarm is 0 (active BCKM/CMPT), the impact of the
ALM-17587 on the system is as follows:
l If the BTS is started, the BCKM/CMPT cannot provide the system clock for the BTS after reporting the alarm. The BTS cannot operate.
l If the BTS is not started, the BTS cannot operate after the BCKM/CMPT reports the alarm.
When the ID of the board that reports the alarm is 1 (standby BCKM/CMPT), the BTS services
are not affected. The BCKM/CMPT hot backup function, however, is not available.
System Actions
If the active BCKM/CMPT reports the alarm and the standby BCKM/CMPT is configured, the
system automatically triggers the active/standby switchover when the clock of the standby
BCKM/CMPT is in the locked state or within the hold capability.
Possible Causes
The 10 MHz crystal oscillator of the BCKM/CMPT is faulty.
Workflow
Figure 2-9 Procedure for handling the ALM-17581
Procedure
Step 1 Keep the spare parts ready.
Bring the BCKM/CMPT to the site.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-28 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 45/114
Step 2 Remove and then insert the BCKM/CMPT.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is
not cleared, go to 3.
Step 3 Replace the BCKM/CMPT.
To replace the BCKM/CMPT that reports the ALM-17581, refer to the BTS Site Maintenance
Guide.
----End
Related Information
None.
2.10 ALM-17586 Number of Locked Satellites Insufficient
Description
The ALM-17586 is reported when the satellites locked by the main processing module (BCKM/
CMPT) satellite receiver are insufficient.
The following situations cause the insufficient satellites locked by the BCKM/CMPT satellite
receiver:
l When the satellites traced by the BCKM/CMPT satellite receiver are insufficient, the
BCKM/CMPT fails to obtain the satellite position because of the bad geometric position
such as small satellite elevation even if the traced satellites are sufficient. As a result, the
BTS system clock performance is affected and the alarm is generated.
l When the system clock does not have the hold capability, the alarm is reported if the
satellites traced by the BCKM/CMPT satellite receiver are insufficient or the position
cannot be obtained.
l When the system clock has the hold capability, the alarm is reported if the satellites traced
by the BCKM/CMPT satellite receiver are insufficient or the position cannot be obtained
in the hold time.
Through the alarm, you can find the fault of the insufficient satellites locked by the BCKM/
CMPT satellite receiver.
NOTE
The situations of insufficient satellites traced are as follows:
l The traced satellites are fewer than four in the case of the GLONASS not-in-position hold.
l The traced satellites are fewer than five in the case of the GPS/GLONASS not-in-position hold.
l The traced satellites are fewer than one or two in the case of the satellite receiver in-position hold.
Attribute
Alarm ID Alarm Severity Alarm Type
17586 Minor Fault
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-29
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 46/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CLK module of the main
processing module
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated: default subunit type
Subunit ID ID of the subunit where the alarm is generated: default subunit ID
Impact on the System
When the ID of the board that reports the alarm is 0 (active BCKM/CMPT), the impact of the
ALM-17586 on the system is as follows:
l If the BTS is started, the clock performance cannot be ensured after the BCKM/CMPT
reports the alarm. The QoS of the BTS is affected.
l If the BTS is not started and the BTS clock reference source is configured with only the board clock, the BTS cannot operate after the BCKM/CMPT reports the alarm
l If the BTS is not started and the BTS clock reference source is configured with an internal
clock, the BTS can operate after the clock is switched to the internal clock. The clock
performance, however, cannot be ensured and the QoS of the BTS is affected.
When the ID of the board that reports the alarm is 1 (standby BCKM/CMPT), the BTS services
are not affected. The BCKM/CMPT hot backup function, however, is not available.
System Actions
If the active BCKM/CMPT reports the alarm and the standby BCKM/CMPT is configured, the
system automatically triggers the active/standby switchover when the clock of the standby
BCKM/CMPT is in the locked state or within the hold capability.
Possible Causes
The causes of the ALM-17586 are as follows.
l When the GPS/GLONASS is installed, the working mode of the BCKM/CMPT satellite
receiver is configured with GLONASS only.
l The BCKM/CMPT satellite receiver is exceptional.
l The interference and the obstructions exist around the satellite antenna.
l The BCKM/CMPT satellite receiver is ineffective.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-30 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 47/114
Workflow
Figure 2-10 Procedure for handling the ALM-17586
Procedure
Step 1 Keep the spare parts ready.
Bring the BCKM/CMPT to the site.
Step 2 Check the working mode of the BCKM/CMPT satellite receiver.
Run the DSP CBTSCFG command to query the working mode of the BTS satellite receiver.
Check whether the working mode of the BCKM/CMPT satellite receiver is GLONASS only.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-31
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 48/114
l If the working mode is GLONASS only, run the SET CBTSCLKSRCMODE command to
change the working mode to GPS+GLONASS. Check whether the alarm is cleared. If the
alarm is cleared, the procedure ends. If the alarm is not cleared, go to 3.
l If the working mode is not GLONASS only, go to 3.
Step 3 Reset the satellite receiver and wait for about 30 minutes.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is
not cleared, go to 5.
Step 4 Replace the BCKM/CMPT.
To replace the BCKM/CMPT that reports the ALM-17586, refer to the BTS Site Maintenance
Guide. Check whether the alarm is cleared.
l If the alarm is cleared, the procedure ends.
l If the alarm is not cleared, go to 5.
Step 5 Reinstall the antenna.
Reinstall the antenna according to the installation guide.
----End
Related Information
The related commands are as follows:
DSP CBTSCFG
SET CBTSCLKSRCMODE
2.11 ALM-17587 Satellite Antenna Open-Circuit
Description
l The ALM-17587 is reported when the cable between the BCKM/CMPT satellite receiver
and the satellite antenna is disconnected.
l The ALM-17587 is also reported when the BCKM/CMPT detects that the feed current in
the cable that connects the satellite receiver and the satellite antenna is small and the satellite
receiver cannot trace the satellite.
Through the alarm, you can find in time the fault in the open circuit of the cable connection
between the satellite receiver and the satellite antenna.
Attribute
Alarm ID Alarm Severity Alarm Type
17587 Minor Fault
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-32 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 49/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CLK module of the main
processing module
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated: default subunit type
Subunit ID ID of the subunit where the alarm is generated: default subunit ID
Impact on the System
When the ID of the board that reports the alarm is 0 (active BCKM/CMPT), the impact of the
ALM-17587 on the system is as follows:
l If the BTS is started, the system is not affected in the hold time because the system clock
has the hold capability. If the hold time expires, the QoS of the BTS is affected.
l
If the BTS is not started and the BTS clock reference source is configured with only the board clock, the BTS cannot operate after the BCKM/CMPT reports the alarm
l If the BTS is not started and the BTS clock reference source is configured with an internal
clock, the BTS can operate after the clock is switched to the internal clock. The clock
performance, however, cannot be ensured and the QoS of the BTS is affected.
When the ID of the board that reports the alarm is 1 (standby BCKM/CMPT), the BTS services
are not affected. The standby BCKM/CMPT clock can provide the BCKM/CMPT hot backup
function in the hold time when the active BCKM/CMPT is faulty. The BCKM/CMPT hot backup
function, however, is not available when the hold time expires.
System Actions
If the active BCKM/CMPT whose clock cannot be held reports the alarm and the standby
BCKM/CMPT is configured, the system automatically triggers the active/standby switchover
when the clock of the standby BCKM/CMPT is in the locked state or within the hold capability.
If the active BCKM/CMPT whose clock can be held reports the alarm, the system clock is held
after the alarm is reported. After the active BCKM/CMPT clock hold time expires and the
standby BCKM/CMPT is configured, the system automatically triggers the active/standby
switchover when the clock of the standby BCKM/CMPT is in the locked state or within the hold
capability.
Possible Causes
The causes of the ALM-17587 are as follows.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-33
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 50/114
l The GPS antenna is not installed correctly.
l The GPS feeder is damaged or connected insecurely, or the cable between the GPS receiver
and the BCKM/CMPT front panel is damaged.
l The lightning arrester is ineffective.
Workflow
Figure 2-11 Procedure for handling the ALM-17587
Procedure
Step 1 Keep the spare parts ready.
The spare parts are as follows:
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-34 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 51/114
l GPS feeder
l White cables in the board
l Lightning arrester
Step 2 Check whether the installation environment of the GPS antenna is proper.
The items for the installation environment of the GPS antenna are as follows:
l The installation location is open without high buildings around.
l It is far from the small adjunct buildings of the rooftop.
l The usable installation area is large.
l The antenna upward vertical angle is greater than 90°.
l It is far from the electromagnetic signal sources that are similar to the operating band of the
GPS (1.575 GHz).
Check whether the installation environment of the GPS antenna is proper.
l If the GPS antenna is not installed correctly, handle the problems that exist in the installation.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm
is not cleared, go to 3.
l If the GPS antenna is installed correctly, go to 3.
Step 3 Check whether the GPS feeder is intact and correctly connected.
l If the GPS feeder is damaged or connected insecurely, refer to the BTS Site Maintenance
Guide to replace the feeder and ensure that the connection is reliable. Check whether the
alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to
4.
l If the GPS feeder is securely connected, go to 4.
Step 4 Check whether the lightning arrester is ineffective.
l If the lightning arrester is ineffective, refer to the BTS Site Maintenance Guide to replace
the lightning arrester.
l If the lightning arrester is normal, the procedure ends.
----End
Related Information
None.
2.12 ALM-17588 Satellite Antenna Short-Circuited
Description
The ALM-17588 is reported when the main processing module detects that the feed current in
the cable that connects the satellite receiver and the satellite antenna is large.
Through the alarm, you can find in time the fault in the short circuit of the cable connection
between the satellite receiver and the satellite antenna.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-35
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 52/114
Attribute
Alarm ID Alarm Severity Alarm Type
17588 Minor Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CLK module of the main processing module
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated: default subunit type
Subunit ID ID of the subunit where the alarm is generated: default subunit ID
Impact on the System
When the ID of the board that reports the alarm is 0 (active BCKM/CMPT), the impact of the
ALM-17588 on the system is as follows:
l If the BTS is started, the system is not affected in the hold time because the system clock
has the hold capability. If the hold time expires, the QoS of the BTS is affected.
l If the BTS is not started and the BTS clock reference source is configured with only the
board clock, the BTS cannot operate after the BCKM/CMPT reports the alarm
l If the BTS is not started and the BTS clock reference source is configured with an internal
clock, the BTS can operate after the clock is switched to the internal clock. The clock
performance, however, cannot be ensured and the QoS of the BTS is affected.
When the ID of the board that reports the alarm is 1 (standby BCKM/CMPT), the BTS services
are not affected
The standby BCKM/CMPT clock can provide the BCKM/CMPT hot backup function in the
hold time. The BCKM/CMPT hot backup function, however, is not available when the hold time
expires.
System Actions
If the active BCKM/CMPT whose clock cannot be held reports the alarm and the standby
BCKM/CMPT is configured, the system automatically triggers the active/standby switchover when the clock of the standby BCKM/CMPT is in locked state or within the hold capability.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-36 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 53/114
If the active BCKM/CMPT whose clock can be held reports the alarm, the system clock is held
after the alarm is reported. After the active BCKM/CMPT clock hold time expires and the
standby BCKM/CMPT is configured, the system automatically triggers the active/standby
switchover when the clock of the standby BCKM/CMPT is in locked state or within the hold
capability.
Possible Causes
The GPS antenna is inundated or the GPS feeder is damaged.
Workflow
Figure 2-12 Procedure for handling the ALM-17588
Procedure
Step 1 Keep the spare parts ready.
Bring the GPS feeder to the site.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-37
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 54/114
Step 2 Connect the BCKM/CMPT by using the standby antenna and cable.
l If the alarm is cleared, you can infer that the original GPS feeder is short-circuited. Go to
4.
l If the alarm is not cleared, go to 3.
Step 3 Disconnect the feeder and the GPS antenna and the feeder and the GPS receiver.
After the connections are interrupted, use a multimeter to measure the impedance between the
shielded layer and the core wire of the feeder.
l If the impedance is more than several megaohms, you can infer that the GPS feeder is not
short-circuited.
l If the impedance is less than several megaohms, you can infer that the original GPS feeder
is short-circuited. Go to 4.
Step 4 Replace the feeder and protect the GPS antenna system against the water.
----End
Related Information
None.
2.13 ALM-17855 BER of E1/T1 Link Too High
Description
When the bit error rate (BER) of the E1/T1 link exceeds the threshold, the ALM-17855 is
reported.
The transmission module measures the BER of the E1/T1 link every 10 minutes. If the BER is
higher than the threshold, the transmission module reports the alarm.
Through the alarm, you can find the fault in the BER of the E1/T1 link in time.
Attribute
Alarm ID Alarm Severity Alarm Type
17855 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: BCIM and CMPT
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-38 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 55/114
Name Meaning
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
1
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the E1/T1 link where the alarm is generated, with the value ranging from
0 to 7
Impact on the System
The impact of the ALM-17855 on the system is as follows:
l The quality of the voice services carried by the link is decreased or the calls are dropped.
l The transmission rate of the data service carried by the link decreases or the transmission
is interrupted.
System Actions
None.
Possible Causes
The causes of the ALM-17855 are as follows:
l
Poor contact of the E1/T1 link l Bad grounding performance of the E1/T1 cable
l Damaged shielded layer of the E1/T1 cable
l Faulty transmission network
l Inconsistent configuration of the impedance
l High BER of the optical transmission link
l High BER of the E1/T1 link
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-39
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 56/114
Workflow
Figure 2-13 Procedure for handling the ALM-17855
Procedure
Step 1 Check whether the optical transmission link is normal.
l If the optical transmission link is exceptional, improve the transmission quality of the optical
transmission link. Check whether the alarm is cleared. If the alarm is cleared, the procedure
ends. If the alarm is not cleared, go to 2.
l If the optical transmission link is normal, go to 2.
Step 2 Check whether the E1/T1 cable and its shielded layer are normal.
Check whether the grounding of the E1/T1 cable is normal and whether the shielded layer of
the cable is damaged.
l If the connection is exceptional, clear the fault caused by the poor contact or the damage on
the cable. Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 3.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-40 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 57/114
l If the connection is normal, go to 3.
Step 3 Contact the transmission engineers to check whether the equipment or transmission cable is
normal.
----End
Related Information
None.
2.14 ALM-17883 Transmission Module IP AddressConflicting
Description
The ALM-17883 is reported when the IP address of the FE port of the QC54BCIM conflicts
with the IP address of other equipment in the same network segment.
Through the alarm, you can find in time the fault in the IP address of the FE port of the BCIM.
Attribute
Alarm ID Alarm Severity Alarm Type
17883 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: BCIM
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
3
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the FE port where the alarm is generated, with the value ranging from 0
to 1
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-41
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 58/114
Impact on the System
The data transmission through the FE port is interrupted. As a result, the services carried over
the FE port are interrupted.
System Actions
None.
Possible Causes
The IP address of the FE port of the BCIM conflicts with the IP address of other equipment in
the network.
Procedure
Step 1 Run the DSP CBTSFEPORTINFO command. Check whether the configured IP address of theFE port is consistent with the planned IP address.
If they are not consistent, run the RMV CBTSFEPORT command to delete the old address of
the FE port, and then run the ADD CBTSFEPORT command to add a new IP address to the FE
port.
Step 2 If they are consistent, the corrective procedure ends.
----End
Related Information
The related commands are as follows:
DSP CBTSFEPORTINFO
RMV CBTSFEPORT
ADD CBTSFEPORT
2.15 ALM-18131 DRC Alarm of Private-Line Users
Description
The ALM-18131 is reported when the CECM/HECM detects that the data rate of download
service does not meet the requirement of the subscription rate owing to the poor quality of the
air interface.
The CECM/HECM periodically checks the data rate control (DRC) of private-line users. When
the CECM/HECM detects that the download rate indicated by the DRC value is less than eight
times as big as the subscription rate, the CECM/HECM considers that the air interface
interference is large and reports the alarm. When the CECM/HECM detects that the download
rate indicated by the DRC value reaches eight times as big as the subscription rate, the alarm is
cleared.
Through the alarm, you can find the fault in time in the DRC download speed of private-lineusers.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-42 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 59/114
Attribute
Alarm ID Alarm Severity Alarm Type
18131 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CECM and HECM
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the SystemThe quality of the forward air interface is poor and the subscription speed of private-line users
cannot be ensured.
System Actions
None.
Possible Causes
The quality of the radio channel environment decreases.
Procedure
Step 1 Check the radio channel environment of the area in which the dedicated subscriber is located.
Clear the factors that may cause interference.
Step 2 Degrade the dedicated subscriber to a common subscriber so that the MS can receive the radio
signals in good quality from the BTS.
----End
Related Information
None.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-43
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 60/114
2.16 ALM-18132 PID Delay Alarm
DescriptionWhen the delay of BCMCS service data packet exists in the Abis interface, the ALM-18132 is
reported.
When the CECM/HECM is started, it identifies the delay alarm threshold through the process
identity (PID) of the miscellaneous parameter that is used to configure the broadcast information
flow. When the PID delay exceeds the threshold, the CECM/HECM reports the alarm. After
five minutes, the alarm is cleared if the PID delay is smaller than the threshold.
Through the alarm, you can find in time the fault in the delay of the BCMCS service data.
Attribute
Alarm ID Alarm Severity Alarm Type
18132 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CECM and HECM
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The quality of the BCMCS services decreases or the BCMCS services are interrupted.
System Actions
None.
Possible Causes
The causes of the ALM-18132 are as follows:
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-44 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 61/114
l The BSC or the BTS clock is faulty.
l The delay of the Abis link is long.
Workflow
Figure 2-14 Procedure for handling the ALM-18132
Procedure
Step 1 Check whether the clock alarms exist in the CLK module of the main processing module.l If the clock alarms exist, clear the alarms. Check whether the ALM-18132 is cleared. If the
alarm is cleared, the procedure ends. If the ALM-18132 is not cleared, go to 2.
l If the clock alarms do not exist, go to 2.
Step 2 Check whether the clock alarms exist in the BSC.
l If the clock alarms exist, clear the alarms. Check whether the ALM-18132 is cleared. If the
alarm is cleared, the procedure ends. If the ALM-18132 is not cleared, go to 3.
l If the clock alarms do not exist, go to 3.
Step 3 Check whether the transmission alarms exist.
l If the transmission alarms exist, clear the alarms.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-45
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 62/114
l If the transmission alarms do not exist, the procedure ends.
----End
Related Information
None.
2.17 ALM-18136 DSP Main Clock Abnormal
Description
When the digital signal processor (DSP) main clock of the CECM/HECM is exceptional, the
ALM-18136 is reported.
The CECM/HECM periodically checks the register of the FPGA clock signal alarm to determine
whether the 80 MHz clock is faulty. If the 80 MHz clock is faulty, the DSP main clock signal
is exceptional and the alarm is reported.
The alarm is associated with the 25 MHz clock alarm, 60 MHz clock alarm, and 125 MHz clock
alarm. When the ALM-18136 is reported, you can infer that other clocks are also faulty. Only
the 80 MHz clock alarm and the DSP main clock alarm, however, are reported.
Through the alarm, you can check in time whether the DSP main clock is exceptional.
Attribute
Alarm ID Alarm Severity Alarm Type
18136 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CECM and HECM
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-46 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 63/114
Impact on the System
The services carried by the CECM are interrupted.
System Actions None.
Possible Causes
The causes of the ALM-18136 are as follows:
l The crystal oscillator of the signal board is faulty.
l The DSP chip is faulty.
Procedure
Step 1 Check the FPGA clock signal alarm register. Determine whether the 80 MHz clock is faulty.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the CECM/HECM that reports
the ALM-18136.
Step 2 If the equipment of the peer end is normal, the procedure ends.
----End
Related Information
None.
2.18 ALM-18138 No Light from Transmission Port of OpticalModule
Description
The ALM-18138 is reported when the CCPM/CECM/HCPM/HECM detects that the Tx port of
the optical module has no transmit optical power and the optical module of the CCPM/CECM
is in position.
For the configured optical port, the CCPM/CECM/HCPM/HECM periodically checks the status
register of the optical port. By checking the status register of the optical port, the CCPM/CECM/
HCPM/HECM determines whether the fault of no transmitted optical power exists.
Through the alarm, you can check in time whether the optical module is normal.
Attribute
Alarm ID Alarm Severity Alarm Type
18138 Major Fault
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-47
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 64/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, and
HECM
Board ID ID of the board where the alarm is generated
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
Subunit type Type of the subunit where the alarm is generated
Subunit ID Optical port of the board where the alarm is generated, with the value ranging
from 0 to 2
Impact on the System
The impact of the ALM-18138 on the system is as follows:
l The peer end equipment of the optical port is unavailable.
l The services are interrupted.
System Actions
None.
Possible Causes
The optical module of the CCPM/CECM/HCPM/HECM is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-48 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 65/114
Workflow
Figure 2-15 Procedure for handling the ALM-18138
Procedure
Step 1 Remove and then insert the optical module.
l Check whether the alarm is cleared. If the alar m is cleared, the procedure ends.
l If the alarm is not cleared, go to 2.
Step 2 Replace the optical module.
To replace the faulty optical module that reports the ALM-18138, refer to the BTS Site
Maintenance Guide.
----End
Related Information
None.
2.19 ALM-18139 Signal Loss at Reception Port of OpticalModule
Description
The ALM-18139 is reported when the optical module detects that the optical signals received
at the receiving port are lost and the optical module of the CCPM/CECM/HCPM/HECM is in
position.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-49
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 66/114
When the CCPM/CECM/HCPM/HECM is powered on, it periodically checks the status of the
optical module and the fiber. If the CCPM/CECM/HCPM/HECM detects that the received
signals of the optical module are lost, it reports the alarm.
Through the alarm, you can find in time the fault in the fiber or the optical module of the local
end or the peer end.
Attribute
Alarm ID Alarm Severity Alarm Type
18139 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, and
HECM
Board ID ID of the board where the alarm is generated
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The ALM-18139 has the following impacts on the system:
l The optical channel of the optical module cannot carry services. As a result, the
communication between the local end equipment and the peer end equipment is interrupted.
l After the fault occurs, all the service requests carried by the fiber fail.
System Actions
None.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-50 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 67/114
Possible Causes
The causes of ALM-18139 are as follows:
l The fiber of the local end or the peer end is not connected tightly to the optical module.
l The fiber type of the local end or the peer end is incompatible with the optical module.
l The optical module of the local end of the CCPM/CECM/HCPM/HECM is faulty and
cannot identify the optical signals.
l The optical port or the optical module of the peer end equipment is faulty and cannot
transmit optical signals.
Figure 2-16 Procedure for handling the ALM-18139
Procedure
Step 1 Check whether the fiber of the local end is connected tightly to the optical module.
l If they are not connected tightly, insert the fiber into the port of the optical module. Check
whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not
cleared, go to 2.
l If they are connected tightly, go to 2.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-51
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 68/114
Step 2 Check whether the optical module and the fiber type of the local end are compatible.
l If they are incompatible, refer to the BTS Site Maintenance Guide to replace the local optical
module that reports the ALM-18139. Check whether the alarm is cleared. If the alarm is
cleared, the procedure ends. If the alarm is not cleared, go to 3.
l If they are compatible, go to 3.
Step 3 Check whether the fiber of the peer end is connected tightly to the optical module.
l If they are not connected tightly, insert the fiber into the port of the optical module. Check
whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not
cleared, go to 4.
l If they are connected tightly, go to 4.
Step 4 Check whether the optical module and fiber type of the peer end are compatible.
l If they are incompatible, refer to the BTS Site Maintenance Guide to replace the peer optical
module that reports the ALM-18139.
l If they are compatible, the procedure ends.
----End
Related Information
The related commands are as follows:
DSP CBTSBRDVER
DSP CBTSBRDSPECSTAT
2.20 ALM-18140 Transmission Power Too High at OpticalModule
Description
The ALM-18140 is reported when the optical module detects that the transmission power at the
receiving port is too high and the optical module of the CCPM/CECM/HCPM/HECM is in
position.
The fault detection of the optical module shows that the transmission power is too high. No
matter whether the fiber is connected, the optical module reports the alarm as soon as the module
detects the fault.
Through the alarm, you can find in time the fault in the transmission power of the optical module.
Attribute
Alarm ID Alarm Severity Alarm Type
18140 Major Fault
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-52 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 69/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, and
HECM
Board ID ID of the board where the alarm is generated
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
Subunit type Type of the subunit where the alarm is generated
Subunit ID Optical port of the board where the alarm is generated, with the value ranging
from 0 to 2
Impact on the System
The impact of the ALM-18140 on the system is as follows:
l The services carried by the fiber that is connected to the optical module are interrupted.
l After the fault occurs, all the service requests carried by the fiber fail.
System Actions
None.
Possible CausesThe optical module of the local end is faulty.
Procedure
Step 1 Check the optical module.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the local optical module that
reports the ALM-18140.
Step 2 If it is normal, the procedure ends.
----End
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-53
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 70/114
Related Information
The related commands are as follows:
DSP CBTSBRDVER
DSP CBTSBRDSPECSTAT
2.21 ALM-18141 Transmission Power Too Low at OpticalModule
Description
The ALM-1814 is reported when the optical module detects that the transmission power at the
receiving port is too low and the optical module of the CCPM/CECM/HCPM/HECM is in
position.
The fault detection of the optical module shows that the transmission power is too low. No matter
whether the fiber is connected, the optical module reports the alarm as soon as the module detects
the fault.
Through the alarm, you can find in time the fault in the transmission power of the optical module.
Attribute
Alarm ID Alarm Severity Alarm Type
18141 Minor Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, and
HECM
Board ID ID of the board where the alarm is generated
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
Subunit type Type of the subunit where the alarm is generated
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-54 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 71/114
Name Meaning
Subunit ID Optical port of the board where the alarm is generated, with the value ranging
from 0 to 2
Impact on the System
The strength of the optical signals received by the optical module of the peer end is too low. As
a result, the services carried by the fiber that is connected to the optical module are interrupted.
After the fault occurs, all the service request carried by the fiber fail.
System Actions
None.
Possible Causes
The optical module of the local end is faulty.
Procedure
Step 1 Check the optical module.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the local optical module that
reports the ALM-18141.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
2.22 ALM-18142 Reception Power Too High at OpticalModule
Description
The ALM-18142 is reported when the CCPM/CECM/HCPM/HECM detects that the power of
the signal received from the receiving port of the optical module is too high.
Through the alarm, you can check in time whether the optical fiber is damaged or the optical
module is faulty.
Attribute
Alarm ID Alarm Severity Alarm Type
18142 Minor Fault
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-55
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 72/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, and
HECM
Board ID ID of the board where the alarm is generated
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
Subunit type Type of the subunit where the alarm is generated
Subunit ID Optical port of the board where the alarm is generated, with the value ranging
from 0 to 2
Impact on the System
The impact of the ALM-18142 on the system is as follows:
l The components of the optical module are faulty.
l The services are interrupted.
System Actions
None.
Possible Causes
The causes of the ALM-18142 are as follows:
l The optical module and the optical module type are incompatible.
l The optical module and the optical fiber type are incompatible.
l The optical module of the local end is faulty.
l The optical port of the peer end equipment is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-56 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 73/114
Workflow
Figure 2-17 Procedure for handling the ALM-18142
Procedure
Step 1 Check whether the optical module and the optical module type are compatible.
l If they are incompatible, refer to the BTS Site Maintenance Guide to replace the optical
module that reports the ALM-18142. Check whether the alarm is cleared. If the alarm is
cleared, the procedure ends. If the alarm is not cleared, go to 2.
l If they are compatible, go to 2.
Step 2 Check whether the optical module and the optical fiber type are compatible.
l If they are incompatible, refer to the BTS Site Maintenance Guide to replace the optical fiber.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm
is not cleared, go to 3.
l If they are compatible, go to 3.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-57
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 74/114
Step 3 Check whether the optical module of the local end is faulty.
l If it is faulty, refer to the BTS Site Maintenance Guide to replace the local optical module
that reports the ALM-18142. Check whether the alarm is cleared. If the alarm is cleared, the
procedure ends. If the alarm is not cleared, go to 4.
l If it is normal, go to 4.
Step 4 Check whether the optical port of the peer end equipment is faulty.
l If the equipment of the peer end is faulty, clear the fault of it.
l If the equipment of the peer end is normal, the procedure ends.
----End
Related Information
None.
2.23 ALM-18143 Reception Power Too Low at OpticalModule
Description
The ALM-18143 is reported when the CCPM/CECM/HCPM/HECM detects that the power of
the signal received from the receiving port of the optical module is too low.
The CCPM/CECM/HCPM/HECM can retrieve the information about the rate of the configuredoptical port. The information is saved in I2C. The CCPM/CECM/HCPM/HECM determines
whether to report the alarm based on the flag bit of the low receiving power received from the
optical port. In normal cases, the flag bit is 0. When the power of the optical port is too low, the
flag bit is 1 and the CCPM/CECM reports the alarm.
Through the alarm, you can check in time whether the optical fiber is damaged or the optical
module is faulty.
Attribute
Alarm ID Alarm Severity Alarm Type
18143 Minor Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-58 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 75/114
Name Meaning
Board type Type of the board where the alarm is generated: CCPM, CECM, HCPM, and
HECM
Board ID ID of the board where the alarm is generated
l CCPM (0-5)
l CECM (0-5)
l HCPM (0-5)
l HECM (0-5)
Subunit type Type of the subunit where the alarm is generated
Subunit ID Optical port of the board where the alarm is generated, with the value ranging
from 0 to 2
Impact on the System
The impact of the ALM-18143 on the system is as follows:
l The equipment at the peer end cannot work.
l The services are interrupted.
System Actions
None.
Possible Causes
The causes of the ALM-18143 are as follows:
l The receiving optical fiber and the transmitting optical fiber of the local end or the peer
end are connected incorrectly or insecurely.
l The optical module and the optical fiber type are incompatible or the optical fiber is
disconnected.
l The optical module of the local end is faulty.
l The optical module of the CCPM/CECM/HCPM/HECM is faulty.
l The optical port of the peer end equipment is faulty.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-59
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 76/114
Workflow
Figure 2-18 Procedure for handling the ALM-18143
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-60 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 77/114
Procedure
Step 1 Check whether the receiving and transmitting optical fibers of the local end are connected
correctly.
l
If the optical fibers are connected incorrectly, reconnect them. Check whether the alarm iscleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 2.
l If the optical fibers are connected correctly, go to 2.
Step 2 Check whether the optical fibers are connected tightly.
l If the optical fibers are not connected tightly, reconnect them. Check whether the alarm is
cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 3.
l If the optical fibers are connected properly, go to 3.
Step 3 Check whether the optical module and the optical fiber type are compatible.
l If they are incompatible, refer to the BTS Site Maintenance Guide to replace the optical fiber.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarmis not cleared, go to 4.
l If they are compatible, go to 4.
Step 4 Check whether the optical module of the local end is faulty.
l If it is faulty, refer to the BTS Site Maintenance Guide to replace the local optical module
that reports the ALM-18143. Check whether the alarm is cleared. If the alarm is cleared, the
procedure ends. If the alarm is not cleared, go to 5.
l If it is normal, go to 5.
Step 5 Check whether the CCPM/CECM/HCPM/HECM is faulty.
l
If it is faulty, refer to the BTS Site Maintenance Guide to replace the CCPM/CECM/HCPM/HECM that reports the ALM-18143. If the alarm is not cleared, go to 6.
l If it is normal, go to 6.
Step 6 Check whether the equipment of the peer end is faulty.
l If the equipment of the peer end is faulty, clear the fault of it.
l If the equipment of the peer end is normal, the procedure ends.
----End
Related Information
None.
2.24 ALM-18150 CSM5000 Failure Alarm
Description
When the CSM5000 chip on the CCPM is faulty, the ALM-18150 is reported.
When the CCPM is started, all the CSM5000 chips on the CCPM perform self-check. If the
check fails, the ALM-18150 is reported.
Through the ALM-18150, the faulty CSM5000 chip on the CCPM can be located in time.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-61
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 78/114
Attribute
Alarm ID Alarm Severity Alarm Type
18150 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
2
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The impact of the ALM-18150 on the system is as follows:
l The faulty chip cannot be used for the radio resource allocation.
l The CE resources assigned on the forward and reverse channels of the CCPM is reduced.
l The maximum number of the accessed users decreases.
l The system reports that the CCPM must be replaced.
System Actions
None.
Possible Causes
The causes of the ALM-18150 are as follows:
l The input clock of the chip on the backplane is exceptional.
l The CSM5000 chip is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-62 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 79/114
Workflow
Figure 2-19 Procedure for handling the ALM-18150
Procedure
Step 1 Check whether the input clock of the backplane is exceptional.
l If the input clock of the backplane is exceptional, refer to the BTS Maintenance Guide to
replace the BCKM that reports the ALM-18150. Check whether the alarm is cleared. If the
alarm is cleared, the procedure ends. If the alarm is not cleared, go to 2.
l If the input clock of the backplane is normal, go to 2.
Step 2 Check whether the CCPM is exceptional.
l If the CCPM is exceptional, refer to the BTS Maintenance Guide to replace the CCPM that
reports the ALM-18150.
l If the CCPM is normal, the procedure ends.
----End
Related Information
The related commands are as follows:
DSP CBTSBRDVER
DSP CBTSLOG
DSP CBTSBRDSTAT
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-63
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 80/114
2.25 ALM-18151 All CSM5000 Failure Alarm
Description
When all the CSM5000 chips on the CCPM are faulty, the ALM-18151 is reported.
After the CCPM is operational, all the CSM500 chips on the CCPM perform self-check. If the
check fails, the ALM-18151 is reported.
Through the ALM-18151, the faulty CSM5000 chip on the CCPM can be located in time.
Attribute
Alarm ID Alarm Severity Alarm Type
18151 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated:
CCPM
Board ID ID of the board where the alarm is generated:
l CCPM (0-2)
l CECM (0-2)
Subunit type Type of the subunit where the alarm is
generated
Subunit ID ID of the subunit where the alarm is generated
ID of start circuit ID of E1 logic start circuit of blocked trunk
circuits, with the value ranging from 0 to 65535
Number of blocked circuits Value range: 0 to 65535
Whether to block all circuits of the signaling
point
The meanings of values 0 and 1 are as follows:
l 0: No
l 1: Yes
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-64 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 81/114
Name Meaning
Whether to block multiple circuits The meanings of values 0 and 1 are as follows:
l 0: No
l 1: Yes
Whether to block all circuits within the
permissible range
The meanings of values 0 and 1 are as follows:
l 0: No
l 1: Yes
Circuit bit Indicated by hex, with the value ranging from
0 to 0xFFFFFFFF
For example, when the circuits 1 to 3 are
blocked, the circuit bit is 0x70000000.
Fault cause 07 H (OAM&P intervention), 20 H (equipment
fault) or 21 H (no available radio resources)
Impact on the System
All the chips on the CCPM are unavailable. Therefore, the CCPM cannot bear any service.
System Actions
The CCPM/CECM is started after eight minutes and checks the chips again.
Possible Causes
The causes of the ALM-18151 are as follows:
l The input clock of the chip on the backplane is faulty.
l All the CSM5000 chips are faulty.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-65
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 82/114
Workflow
Figure 2-20 Procedure for handling the ALM-18151
Procedure
Step 1 Check whether the input clock on the backplane is normal.
l If the input clock of the backplane is exceptional, refer to the BTS Maintenance Guide to
replace the BCKM that reports the ALM-18151. Check whether the ALM-18151 is cleared.
If the alarm is cleared, the procedure ends. If the ALM-18151 is not cleared, go to 2.
l If the input clock of the backplane is normal, go to 2.
Step 2 Check whether the CCPM is exceptional.
l If the CCPM is exceptional, refer to the BTS Maintenance Guide to replace the CCPM that
reports the ALM-18151.
l If the CCPM is normal, the procedure ends.
----End
Related Information
The related commands are as follows:
DSP CBTSBRDVER
DSP CBTSLOG
DSP CBTSBRDSTAT
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-66 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 83/114
2.26 ALM-18160 CSM6700 Failure Alarm
Description
When the CSM6700 chip on the CCPM is faulty, the ALM-18150 is reported.
When the CCPM is started, all the CSM6700 chips on the CCPM perform self-check. If the
check fails, the ALM-18150 is reported.
Through the ALM-18150, the faulty CSM6700 chip on the CCPM can be located in time.
Attribute
Alarm ID Alarm Severity Alarm Type
18150 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: CCPM
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The impact of the ALM-18160 on the system is as follows:
l The faulty chip cannot be used for the radio resource allocation.
l The CE resources assigned on the forward and reverse channels of the CCPM is reduced.
l The maximum number of the accessed users decreases.
l The system reports that the CCPM must be replaced.
System Actions
None.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-67
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 84/114
Possible Causes
The causes of the ALM-18160 are as follows:
l The input clock of the chip on the backplane is exceptional.
l The CSM6700 chip is faulty.
Workflow
Figure 2-21 Procedure for handling the ALM-18160
Procedure
Step 1 Check whether the input clock on the backplane is normal.
l If the input clock of the backplane is exceptional, refer to the BTS Site Maintenance Guide
to replace the BCKM that reports the ALM-18160. Check whether the alarm is cleared. If
the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 2.
l If the input clock of the backplane is normal, go to 2.
Step 2 Check whether the CCPM is exceptional.
l If the CCPM is exceptional, refer to the BTS Site Maintenance Guide to replace the CCPM
that reports the ALM-18160.
l If the CCPM is normal, the procedure ends.
----End
Related Information
The related commands are as follows:
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-68 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 85/114
DSP CBTSBRDVER
DSP CBTSLOG
DSP CBTSBRDSTAT
2.27 ALM-18345 DAC Clock of Transmitting ChannelAbnormal
Description
When the digital analog converter (DAC) of the STDM/CMTR/OMTR detects the unlocked
phase-locked loop (PPL), the ALM-18345 is reported.
Through the alarm, you can find in time the fault in the DAC of the transmission channel.
Attribute
Alarm ID Alarm Severity Alarm Type
18345 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated
Subunit type Type of the subunit where the alarm is generated
Subunit ID Forward channel of the STDM where the alarm is generated, with the value
ranging from 0 to 2
Impact on the System
The services supported by the sectors where the DAC is located are interrupted.
System Actions
None.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-69
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 86/114
Possible Causes
The STDM/CMTR/OMTR is faulty.
ProcedureStep 1 Check the STDM/CMTR/OMTR.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the STDM/CMTR/OMTR that
reports the ALM-18345.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
2.28 ALM-18350 Main and Diversity DDCs UnavailableSynchronously
Description
When the digital down change (DDC) of the receiving main and diversity fails at the same time,
the ALM-18350 is reported.
Through the alarm, you can find in time the fault in the DDC of the receiving main and diversity.
Attribute
Alarm ID Alarm Severity Alarm Type
18350 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-70 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 87/114
Name Meaning
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The services of the sector carrier where the STDM/CMTR/OMTR is located are interrupted.
System Actions
None.
Possible Causes
The cause of the ALM-18350 is that the DDCs of the main and diversity of the STDM/CMTR/OMTR are faulty.
Workflow
Figure 2-22 Procedure for handling the ALM-18350
Procedure
Step 1 Reset the STDM/CMTR/OMTR.
l Check whether the alarm is cleared. If the alarm is cleared, the procedure ends.
l If the alarm is not cleared, go to 2.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-71
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 88/114
Step 2 Power off the RF module.
Step 3 Replace the STDM/CMTR/OMTR.
To replace the STDM/CMTR/OMTR that reports the ALM-18350, refer to the BTS Site
Maintenance Guide.
----End
Related Information
None.
2.29 ALM-18356 TRM Blocked Because of the Command
Description
When the sector carriers of the BTS are caused by the user command, the ALM-18356 is
reported.
Through the alarm, you can find in time the fault in the carrier blocking caused by the user
command.
Attribute
Alarm ID Alarm Severity Alarm Type
18356 Warning Fault/recovery
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
If the sector carriers of the BTS are blocked, the services carried by this sector carriers areinterrupted.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-72 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 89/114
System Actions
None.
Possible CausesThe sector carries of the BTS are blocked by the user command.
Procedure
Step 1 Open the LMT Service Maintenance System.
Step 2 Run the UBL CBTSSECTORCARRIER command to unblock the corresponding sector carriers.
----End
Related InformationThe related commands are as follows:
UBL CBTSSECTORCARRIER
2.30 ALM-18363 Voltage of Power Amplification PowerSupply Too High
Description
The software checks the voltage of the SPAM/CMPA/OMPA power supply in real time. When
the voltage of the SPAM power supply exceeds 34 V, the ALM-18363 is reported. When the
voltage of the SPAM power supply is lower than 30 V, the alarm is cleared. When the voltage
of the CMPA/OMPA power supply exceeds 30 V, the ALM-18363 is reported. When the voltage
of the CMPA/OMPA power supply is lower than 28.5 V, the alarm is cleared.
Through the alarm, you can find in time the fault in the voltage of the SPAM/CMPA/OMPA
power supply.
Attribute
Alarm ID Alarm Severity Alarm Type
18363 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-73
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 90/114
Name Meaning
Board type Type of the board where the alarm is generated: SPAM, CMPA, and OMPA
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The SPAM/CMPA/OMPA is powered off, no power is output, and the services carried by the
sector are interrupted.
System Actions
After the alarm related to the overvoltage of the SPAM/CMPA/OMPA power supply is
generated, the system powers off the SPAM/CMPA/OMPA automatically.
Possible Causes
The causes of the ALM-18363 are as follows:
l The power supply module is faulty.
l The SPAM/CMPA/OMPA is faulty.
Procedure
Step 1 Check the output voltage of the power supply module.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the SPAM/CMPA/OMPA that
reports the ALM-18363.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
2.31 ALM-18364 Voltage of Power Amplification PowerSupply Too Low
Description
The software checks the voltage of the SPAM/CMPA/OMPA power supply. When the voltageof the SPAM power supply is less than 20.8 V, the ALM-18364 is reported. When the voltage
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-74 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 91/114
of the SPAM power supply exceeds 25 V, the alarm is cleared. When the voltage of the CMPA/
OMPA power supply is lower than 21 V, the ALM-18364 is reported. When the voltage of the
CMPA/OMPA power supply exceeds 25 V, the alarm is cleared.
Through the alarm, you can find in time the fault in the voltage of the SPAM/CMPA/OMPA
power supply.
Attribute
Alarm ID Alarm Severity Alarm Type
18364 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: SPAM, CMPA, and OMPA
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The SPAM/CMPA/OMPA is powered off, no power is output, and the services carried by the
sector are interrupted.
System ActionsAfter the ALM-18364 is generated, the system powers off the SPAM/CMPA/OMPA
automatically.
Possible Causes
The causes of the ALM-18364 are as follows:
l The voltage of the battery supplying power is too low.
l The power supply module is overloaded.
l The power supply module is faulty.
l The SPAM/CMPA/OMPA is faulty.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-75
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 92/114
Workflow
Figure 2-23 Procedure for handling the ALM-18364
Procedure
Step 1 Check whether the undervoltage is caused by power failure.
l If the undervoltage is caused by power failure, confirm the ALM-18364 after the power is
supplied. Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If
the alarm is not cleared, go to 2.
l If the undervoltage is not caused by power failure, go to 2.
Step 2 Check whether the power supply modules are insufficient.
l If the power supply modules are insufficient, add the power supply modules. Check whether
the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared,
go to 3.
l If the power supply modules are sufficient, go to 3.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-76 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 93/114
Step 3 Replace the power supply module.
To replace the power supply module that reports the ALM-18364, refer to the BTS Site
Maintenance Guide.
l If the alarm is cleared, the procedure ends.
l If the alarm is not cleared, go to 4.
Step 4 Replace the SPAM/CMPA/OMPA.
To replace the SPAM/CMPA/OMPA that reports the ALM-18364, refer to the BTS Site
Maintenance Guide.
----End
Related Information
None.
2.32 ALM-18365 TRM Pre-Distortion Capture Over-Time
Description
When the pre-distortion module is faulty and the data sampling expires, the ALM-18365 is
reported.
Through this alarm, you can find in time the fault in the acquisition time of the pre-distortion
module.
Attribute
Alarm ID Alarm Severity Alarm Type
18365 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-77
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 94/114
Name Meaning
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The specifications for the transmission signal are affected and the call quality may be decreased.
System Actions
None.
Possible Causes
The STDM/CMTR/OMTR is faulty.
Procedure
Step 1 Check the STDM/CMTR/OMTR.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the STDM/CMTR/OMTR that
reports the ALM-18365.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
2.33 ALM-18367 Ratio Between Reference Voltage andFeedback Voltage of Predistortion Module Out of Range
Description
The pre-distortion module checks the ratio of the reference power to the feedback power in real
time. When the ratio exceeds the permissible range, the ALM-18367 is reported.
Through this alarm, you can timely find the fault in the ratio of reference voltage to the feedback
voltage of the STDM/CMTR/OMTR pre-distortion module.
Attribute
Alarm ID Alarm Severity Alarm Type
18367 Major Fault
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-78 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 95/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The specifications for the transmission signal are affected and the call quality may be decreased.
System Actions
None.
Possible Causes
The STDM is faulty.
Procedure
Step 1 Check the STDM/CMTR/OMTR.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the STDM/CMTR/OMTR that
reports the ALM-18367.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-79
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 96/114
2.34 ALM-18368 Predistortion Module Feedback Signal TooSmall
Description
The pre-distortion module checks the strength of the feedback signal in real time. When the
strength of the feedback signal is less than the threshold of the power required for the operation
of the pre-distortion module, the ALM-18368 is reported.
Through this alarm, you can find in time the fault in the feedback signal of the STDM/CMTR/
OMTR pre-distortion module.
Attribute
Alarm ID Alarm Severity Alarm Type
18368 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The specifications for the transmission signal are affected and the call quality may be decreased.
System Actions
None.
Possible Causes
The STDM is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-80 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 97/114
Procedure
Step 1 Check the STDM/CMTR/OMTR.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the STDM/CMTR/OMTR that
reports the ALM-18368.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
2.35 ALM-18376 Communication Link Between Power
Amplification Monitoring Board and TRM Disconnected
Description
The SPAM communicates with the STDM through the serial port. When the communication
between the SPAM monitoring board and the STDM fails, the ALM-18376 is reported. The
CMPA/OMPA communicates with the CMTR/OMTR through the serial port. When the
communication between them fails, the ALM-18376 is reported.
Through this alarm, you can check whether the communication between the STDM/CMTR/
OMTR and the SPAM/CMPA/OMPA monitoring board is normal.
Attribute
Alarm ID Alarm Severity Alarm Type
18376 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-81
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 98/114
Name Meaning
Subunit ID ID of the subunit where the alarm is generated, with the value of 0xff
Impact on the System
The information about the SPAM/CMPA/OMPA cannot be reported. Therefore, the output
power of the SPAM/CMPA/OMPA cannot be monitored.
System Actions
None.
Possible Causes
The causes of the ALM-18376 are as follows:
l The connection between the STDM and the serial port of the SPAM monitoring board is
exceptional.
l The connection between the CMTR and the serial port of the CMPA monitoring board is
exceptional.
l The connection between the OMTR and the serial port of the OMPA monitoring board is
exceptional.
l The SPAM/CMPA/OMPA monitoring board is faulty.
l The STDM/CMTR/OMTR is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-82 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 99/114
Workflow
Figure 2-24 Procedure for handling the ALM-18376
Procedure
Step 1 Power off the RF module.
Step 2 Reconnect the serial cable between the RF module and the PA module.
Power on the RF module after the connection is normal. Check whether the alarm is cleared. If
the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 3.
Step 3 Power off the RF module.
Step 4 Replace the SPAM/CMPA/OMPA.
To replace the SPAM/CMPA/OMPA that reports the ALM-18376, refer to the BTS Site
Maintenance Guide. After the connection is normal, power on the RF module. Check whether
the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go
to 5.
Step 5 Power off the RF module.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-83
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 100/114
Step 6 Replace the STDM/CMTR/OMTR.
To replace the STDM/CMTR/OMTR that reports the ALM-18376, refer to the BTS Site
Maintenance Guide.
----End
Related Information
None.
2.36 ALM-18392 Power Amplification Gain Abnormal
Description
The SPAM/CMPA/OMPA can control the gain. When the gain of the SPAM/CMPA/OMPA
exceeds the permissible range, the ALM-18392 is reported.
Through the alarm, you can find in time the fault in the gain of the SPAM/CMPA/OMPA.
Attribute
Alarm ID Alarm Severity Alarm Type
18392 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID For the STDM, it is the ID of the subunit where the alarm is generated, with the
value ranging from 0 to 2
Impact on the System
The transmit power of the sector carrier of the SPAM/CMPA/OMPA is exceptional and the BTScoverage is affected.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-84 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 101/114
System Actions
None.
Possible CausesThe causes of the ALM-18392 are as follows:
l The RF connection between the STDM and the SPAM is faulty.
l The RF connection between the CMTR and the CMPA is faulty.
l The RF connection between the OMTR and the OMPA is faulty.
l The SPAM/CMPA/OMPA is faulty.
l The STDM/CMTR/OMTR detection circuit is faulty.
Workflow
Figure 2-25 Procedure for handling the ALM-18392
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-85
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 102/114
Procedure
Step 1 Power off the RF module.Step 2 Reconnect the RF cable between the RF module and the PA module.
Power on the RF module and wait for 20 minutes.
l Check whether the alarm is cleared. If the alarm is cleared, the procedure ends.
l If the alarm is not cleared, go to 3.
Step 3 Power off the RF module.
Step 4 Replace the SPAM/CMPA/OMPA.
Refer to the BTS Site Maintenance Guide to replace the SPAM/CMPA/OMPA that reports the
ALM-18392. Ensure that the connection between the RF module and the PA module is proper.
Then power on the RF module and wait for 20 minutes. Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 5.
Step 5 Power off the RF module.
Step 6 Replace the STDM/CMTR/OMTR.
To replace the STDM/CMTR/OMTR that reports the ALM-18392, refer to the BTS Site
Maintenance Guide.
----End
Related Information
None.
2.37 ALM-18394 Power Amplification Over-Temperature
Description
If the operating temperature of the SPAM/CMPA/OMPA is too high, the components are
affected. When the operating temperature of the SPAM/CMPA/OMPA is too high, the
ALM-18394 is reported.
Attribute
Alarm ID Alarm Severity Alarm Type
18394 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-86 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 103/114
Name Meaning
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID For the STDM, it is the ID of the subunit where the alarm is generated, with the
value ranging from 0 to 2
Impact on the System
After the ALM-18394 is reported, the system reduces the output power automatically. Therefore,
the BTS coverage is affected. If the operating temperature increases continuously, the SPAM/
CMPA/OMPA may be powered off.
System Actions
None.
Possible Causes
The causes of the ALM-18394 are as follows:
l The ambient temperature is too high.
l The fan rotation speed is exceptional and the heat dissipation is ineffective.
l The SPAM/CMPA/OMPA is faulty.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-87
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 104/114
Workflow
Figure 2-26 Procedure for handling the ALM-18394
Procedure
Step 1 Check whether the ambient temperature of the equipment room is normal.
l If the ambient temperature of the equipment room is exceptional, take measures to lower the
ambient temperature. Check whether the alarm is cleared. If the alarm is cleared, the
procedure ends. If the alarm is not cleared, go to 2.
l If the ambient temperature of the equipment room is normal, go to 2.
Step 2 Check whether a fan failure alarm is generated.
l If a fan failure alarm exists, remove the fan and check whether something blocks the fan.
(1) If something blocks the fan, remove it. Check whether the alarm is cleared. If the alarm
is cleared, the procedure ends. If the alarm is not cleared, go to 4.
(2) If nothing blocks the fan, go to 3.
l If a fan failure alarm is not generated, check whether the fan rotation speed is exceptional.
(1) If the fan rotation speed is exceptional, go to 3.
(2) If the fan rotation speed is normal, go to 4.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-88 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 105/114
Step 3 Replace the fan.
To replace the fan, refer to the BTS Site Maintenance Guide. Check whether the alarm is cleared.
If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 4.
Step 4 Power on the RF module.
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is
not cleared, go to 5.
Step 5 Power off the RF module.
Step 6 Replace the SPAM/CMPA/OMPA.
Refer to the BTS Site Maintenance Guide to replace the SPAM/CMPA/OMPA that reports the
ALM-18394.
----End
Related Information None.
2.38 ALM-18395 Power Amplification Closed
Description
When the SPAM/CMPA/OMPA is in position, the ALM-18395 is reported if the SPAM/CMPA/
OMPA is powered off.
Through this alarm, you can find in time the status of the SPAM/CMPA/OMPA.
Attribute
Alarm ID Alarm Severity Alarm Type
18395 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-89
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 106/114
Name Meaning
Subunit ID For the STDM, it is the ID of the subunit where the alarm is generated, with the
value ranging from 0 to 2
Impact on the System
After the PA module is powered off, it has no output power. The services on the sector carrier
of STDM/CMTR/OMTR are interrupted.
System Actions
None.
Possible CausesThe causes of the ALM-18395 are as follows:
l The temperature of the SPAM/CMPA/OMPA is too high.
l The power supply voltage of the SPAM/CMPA/OMPA is abnormal.
Workflow
Figure 2-27 Procedure for handling the ALM-18395
Procedure
Step 1 Check whether the temperature of the SPAM/CMPA/OMPA exceeds 95℃.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-90 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 107/114
l If the temperature of the SPAM/CMPA/OMPA exceeds 95℃, see ALM-18394 Power
Amplification Over-Temperature to clear the fault. Check whether the alarm is cleared. If
the alarm is cleared, the procedure ends. If the alarm is not cleared, go to 2.
l If the temperature of the SPAM/CMPA/OMPA is lower than 95℃, go to 2.
Step 2 Check whether the alarm related to the SPAM/CMPA/OMPA power exception is generated.
l If the alarm related to the overvoltage or undervoltage of the SPAM/CMPA/OMPA power
supply is generated, see ALM-18364 Voltage of Power Amplification Power Supply Too
Low and ALM-18363 Voltage of Power Amplification Power Supply Too High to clear the
alarm. Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the
alarm is not cleared, the procedure ends.
l If the alarm related to the overvoltage or undervoltage of the SPAM power supply is not
generated, the procedure ends.
----End
Related Information
None.
2.39 ALM-18400 Standing Wave Alarm
Description
The voltage standing wave ratio (VSWR) is measured in real time based on the ratio of transmit
power to the reflection power. If the VSWR exceeds the threshold, the ALM-18400 is reported.
Through the alarm, you can find in time the fault in the VSWR.
Attribute
Alarm ID Alarm Severity Alarm Type
18400 Major Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-91
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 108/114
Name Meaning
Subunit type Type of the subunit where the alarm is generated
Subunit ID For the STDM, it is the ID of the subunit where the alarm is generated, with thevalue ranging from 0 to 2
Impact on the System
The transmit power of the sector carrier decreases and the BTS coverage is affected.
System Actions
None.
Possible Causes
The causes of the ALM-18400 are as follows:
l The VSWR of the antenna system is too high.
l The connection between the jumper and the STDM/CMTR/OMTR is exceptional.
l The STDM/CMTR/OMTR is faulty.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-92 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 109/114
Workflow
Figure 2-28 Procedure for handling the ALM-18400
Procedure
Step 1 Power off the RF module.
Step 2 Reconnect the jumper of the antenna system to the STDM/CMTR/OMTR.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-93
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 110/114
Check whether the alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is
not cleared, go to 3.
Step 3 Check whether the VSWR of the antenna system is normal.
l If the VSWR is exceptional, check the antenna system and clear the fault. Check whether the
alarm is cleared. If the alarm is cleared, the procedure ends. If the alarm is not cleared, go to
5.
l If the VSWR is normal, check the connection between the jumper at the top of the cabinet
and the STDM/CMTR/OMTR. Check whether the alarm is cleared. If the alarm is cleared,
the procedure ends. If the alarm is not cleared, go to 5.
Step 4 Check whether the VSWR is greater than 2.5.
Check the VSWR at the power input port of the STDM/CMTR/OMTR.
l If the VSWR is greater than 2.5, refer to the BTS Site Maintenance Guide to replace the
STDM/CMTR/OMTR that reports the ALM-18400.
l If the VSWR is less than 2.5, perform 5.
Step 5 Power off the RF module.
Step 6 Replace the STDM/CMTR/OMTR.
To replace the STDM/CMTR/OMTR that reports the ALM-18400, refer to the BTS Site
Maintenance Guide.
----End
Related Information
None.
2.40 ALM-18525 RF Feedback PLL Unlocked
Description
If the phase-locked loop (PLL) of the STDM/CMTR/OMTR in the RF feedback channel is
unlocked, the related service is interrupted. When the PLL of the RF feedback channel is
unlocked, the ALM-18525 is reported.
Through this alarm, you can find in time the fault in the RF PLL unlocked.
Attribute
Alarm ID Alarm Severity Alarm Type
18525 Critical Fault
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-94 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 111/114
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The services of the sector carrier where the STDM/CMTR/OMTR is located are interrupted.
System Actions
None.
Possible CausesThe STDM is faulty.
Procedure
Step 1 Check the STDM/CMTR/OMTR.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the STDM/CMTR/OMTR that
reports the ALM-18525.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
2.41 ALM-18526 RF Reverse PLL Unlocked
Description
If the phase-locked loop (PLL) of the STDM/CMTR/OMTR in the RF reverse channel is
unlocked, the related service is interrupted. When the PLL of the RF reverse channel is unlocked,the ALM-18526 is reported.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-95
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 112/114
Through this alarm, you can find in time the fault in the RF reverse PPL unlocked.
Attribute
Alarm ID Alarm Severity Alarm Type
18526 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The services of the sector carrier where the STDM/CMTR/OMTR is located are interrupted.
System Actions
None.
Possible Causes
The STDM is faulty.
Procedure
Step 1 Check the STDM/CMTR/OMTR. If it is faulty, refer to the BTS Site Maintenance Guide to
replace the STDM/CMTR/OMTR that reports the ALM-18526.
Step 2 If the it is normal, the procedure ends.
----End
Related Information
None.
2 Common Alarm Reference
Airbridge BTS CDMA Base Station
Common Alarm Reference
2-96 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-05-10)
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 113/114
2.42 ALM-18527 RF Forward PLL Unlocked
Description
If the phase-locked loop (PLL) of the STDM/CMTR/OMTR in the RF forward channel is
unlocked, the related service is interrupted. When the PLL of the RF forward channel is unlocked,
the ALM-18527 is reported.
Through this alarm, you can find in time the fault in the RF forward PLL unlocked.
Attribute
Alarm ID Alarm Severity Alarm Type
18527 Critical Fault
Parameters
Name Meaning
BTS name Name of the BTS where the alarm is generated
BTS ID ID of the BTS where the alarm is generated
Board type Type of the board where the alarm is generated: STDM, CMTR, and OMTR
Board ID ID of the board where the alarm is generated, with the value ranging from 0 to
5
Subunit type Type of the subunit where the alarm is generated
Subunit ID ID of the subunit where the alarm is generated
Impact on the System
The services of the sector carrier where the STDM/CMTR/OMTR is located are interrupted.
System Actions
None.
Possible Causes
The STDM/CMTR/OMTR is faulty.
Airbridge BTS CDMA Base Station
Common Alarm Reference 2 Common Alarm Reference
Issue 01 (2010-05-10) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-97
8/3/2019 BTS Common Alarm Reference (V300_01)
http://slidepdf.com/reader/full/bts-common-alarm-reference-v30001 114/114
Procedure
Step 1 Check the STDM/CMTR/OMTR.
If it is faulty, refer to the BTS Site Maintenance Guide to replace the STDM/CMTR/OMTR that
reports the ALM-18527.
Step 2 If it is normal, the procedure ends.
----End
Related Information
None.
2 Common Alarm Reference