CATALOGUE 03/2011
Gas boilers and condensing technology
CA
TALO
GU
E CATALOGUE
INDEX
HEAT PUMPS
AUDAX air/water inverter mono-phase heat pumps p. 6 System integrator electronic control for the management of integrated systems p. 7
LIGHT COMMERCIAL
VICTRIX 115 wall-hung modular condensing boiler for heating only p. 8 VICTRIX 90 wall-hung modular condensing boiler for heating only p. 9 VICTRIX 75 wall-hung modular condensing boiler for heating only p. 10 VICTRIX 50 wall-hung modular condensing boiler for heating only p. 11
CONDENSING BOILERS
WALL-HUNG WITH BUILT-IN STORAGE TANK
VICTRIX Zeus Superior kW with built-in stainless steel storage tank of 54 litres p. 12 VICTRIX Zeus with built-in stainless steel storage tank of 45 litres p. 13
WALL-HUNG COMBI AND HEATING ONLY
VICTRIX Superior kW hi-tech combi with “Aqua Celeris” p. 14 VICTRIX Superior kW X hi-tech heating only p. 15 VICTRIX compact combi p. 16 VICTRIX X compact heating only p. 17 VICTRIX R heating only, for open heating systems p. 18 EOLO Extra kW HP combi for outdoor installation, for high temperature systems p. 19
FLOOR-STANDING WITH BUILT-IN STORAGE TANK
HERCULES Condensing with built-in stainless steel storage tank of 120 litres p. 20
FLOOR-STANDING WITH BUILT-IN STORAGE TANK SOLAR SYSTEM READY
HERCULES Solar with built-in stainless steel storage tank of 200 litres, solar system ready p. 21
NEW
INDEXINDEX
TRADITIONAL BOILERS
WALL-HUNG WITH BUILT-IN STORAGE TANK
ZEUS Superior kW with built-in stainless steel storage tank of 60 litres p. 22 AVIO/ZEUS kW with built-in stainless steel storage tank of 45 litres p. 23
WALL-HUNG COMBI AND HEATING ONLY
MAIOR EOLO combi with “Aqua Celeris” p. 24 NIKE Mini 28 kW Special combi open chamber and conventional flue p. 25 MINI NIKE/EOLO compact instantaneous p. 26 MINI NIKE/EOLO X compact heating only p. 27 NIKE/EOLO Star combi with bithermal heat exchanger p. 28 EOLO Extra kW combi for outdoor installation p. 29
COMBI WATER HEATERS
JULIUS open chamber and conventional flue p. 30 CAESAR 14 / Super CAESAR 17 sealed chamber and fan assisted p. 31
STORAGE TANKS
IMMERSTOR p. 32
MULTI SYSTEM DISTRIBUTION MANIFOLDS
DIMV2 p. 33 DIMV2 TOP p. 34
FLUE SYSTEMS
“GREEN SERIES”
Flue systems for VICTRIX 50/75/90/115 p. 35 Flue system for condensing boilers < 35 kW Ø 60/100 p. 38 Flue system for condensing boilers < 35 kW Ø 80/80 p. 39 Ø 60 mm ducting system p. 40 Ø 80 mm flexible ducting system p. 42
“BLUE SERIES”
Flue systems for traditional boilers Ø 60/100 p. 44 Flue systems for traditional boilers Ø 80/80 p. 45 Flue systems for traditional boilers Ø 80/125 p. 47 Ø 80 mm ducting system p. 49
OPTIONS
Hydraulic system p. 52 Climatic regulation p. 60 Boiler and storage tank unit connection groups p. 64
INDEX OF CODES p. 65
During the life of a boiler, performance is influenced by external factors, e.g. water hardness, atmospheric agents, system limiting, etc.The published data refers to new products correctly installed and used, in accordance with local regulations. N.B. we recommend regular periodic maintenance of the appliance.
NEW
NEW
NEW
• 3 mono-phase versions
• Hot/cold reversible functioning
• Combinable with external storage tank
• Combinable with gas heating boiler
• Inverter rotary compressor
• Electronic thermal expansion valve
• Equipped with modulating fan
• R410A refrigerant gas
• Weekly thermostat for hot/cold functioning (optional)
HE
AT
PU
MP
S
HE
AT
PU
MP
S
AUDAXAir/water inverter mono-phase heat pumps
HYDRAULIC KITS
Type Code
Wall mounting brackets for AUDAX 6-8 kW 3.022154
Connection kit with anti-vibration flexible pipes and shut-off knobs 3.021526
Distribution manifold kit for 2 mixed zones 3.021527
Distribution manifold kit for 1 mixed zone 3.021528
Sanitary priority 3-way valve kit 3.020633
12 litre system expansion vessel kit 3.011679
Integration electric resistance kit for AUDAX 3.021525
Additional 5 kW electric resistance kit for UB 1000-1500 3.020862
Additional 3 kW electric resistance kit for UB 200-300-500 3.020861
Dehumidifier kit 3.021529
Dehumidifier back frame kit 3.022146
Dehumidifier front grille kit 3.022147
Model Dimensions(H x W x P) mm
Empty appliance weight kg
6 kW 864 x 950 x 413 84
8 kW 864 x 950 x 413 92
10 kW 1382 x 1160 x 401 122
Data referred to the following conditions: heating air/water temperature 7°/6°/30°/35° cooling air/water temperature 35°/24°/23°/18°
NB: The technical data are not definitive and may be subject to change.
Model Code Heating output kW
Cooling output kW
COP(heating)
EER(cooling)
Supply tension Refrigerant gas
AUDAX 6 kW 3.021457 6,0 6,0 3,95 4,30 Mono-phase 230V R410A
AUDAX 8 kW 3.021458 7,7 8,0 3,90 3,75 Mono-phase 230V R410A
AUDAX 10 kW 3.021459 10,0 9,8 4,00 4,00 Mono-phase 230V R410A
nEW
System integrator
Electronic control with microprocessor for the management of integrated systems. It can manage complex systems, for example a boiler, a heat pump and a solar thermal system; the integrator makes an economic convenience calculation, deciding whether to activate the boiler or the heat pump according to the respective efficiency parameters. In particular, the system integrator can calculate the COP (Coefficient of Performance) of the heat pump and compare it to a minimum value of functional convenience. In order to make such evaluations, it acquires a series of inlet parameters, among which the external temperature and the system inlet set temperature.
Electronic control for the management of integrated systems
THERMOREGULATING KITS
Main grid
1
2
3
4
5
6
7
8
KeySystem controllerHERCULES Solar 26 AUDAX heat pumpFlat-plate collectorsDehumidifier wall recessed Photovoltaic modulesInverter3-way diverter valve
Integrated system with AUDAX and HERCULES Solar 26
Type Code
System controller 3.021522
System controller expansion kit 3.021547
Type Code
Weekly thermostat for hot/cold functioning 3.021521
Zone controller 3.021523
Temperature/humidity active sensor kit 3.021524
12345678
76
• Heat output of 111 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Modulating heat output from 25 to 100%
• Possible indoor or outdoor installation
• Double NTC probe for optimum temperature control
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Possibility of installation in cascade (up to 8 appliances)
• Hydraulic options and flue systems for cascade installations(up to 3 appliances)
• Possibility to connect a separate storage tank unit
• Standard frost protection up to -5 °C
• Heat output of 90 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Modulating heat output from 25 to 100%
• Possible indoor or outdoor installation
• Double NTC probe for optimum temperature control
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Possibility of installation in cascade (up to 8 appliances)
• Hydraulic options and flue systems for cascade installations(up to 3 appliances)
• Possibility to connect a separate storage tank unit
• Standard frost protection up to -5 °C
LIG
HT
CO
MM
ER
CIA
L
LIG
HT
CO
MM
ER
CIA
L
VICTRIX 115 VICTRIX 90Wall-hung modular condensing boiler for heating only Wall-hung modular condensing boiler for heating only
Dimensions(H x W x P) mm
Empty appliance weight kg
1010 x 600 x 610 105,5
Dimensions(H x W x P) mm
Empty appliance weight kg
1010 x 600 x 610 97,5
The price of VICTRIX 115 boiler does not include the “Green Series” flue kit, to be ordered separately. The price of VICTRIX 90 boiler does not include the “Green Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only. For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS MAIN FLUE KITS
MAIN OPTIONS MAIN OPTIONS
Type Code
Terminal horizontal outlet kit Ø 80 3.015255
Terminal vertical outlet kit Ø 80 3.015256
Type Code
Terminal horizontal outlet kit Ø 80 3.015255
Terminal vertical outlet kit Ø 80 3.015256
Type Code
External probe 3.015266
Cascade and zones regulator 3.015244
Zone manager 3.015264
Type Code
External probe 3.015266
Cascade and zones regulator 3.015244
Zone manager 3.015264
Model CodeN.G.L.P.G.
Heat outputkW
Efficiency at nominal heat output
Protectionindex
80-60 °C 50-30 °C 40-30 °C
VICTRIX 115 1 I 3.0204263.020426GPL 111,0 98,4% 106,8% 108,7% IPX5D
Model CodeN.G.L.P.G.
Heat outputkW
Efficiency at nominal heat output
Protectionindex
80-60 °C 50-30 °C 40-30 °C
VICTRIX 90 1 l 3.0204253.020425GPL 90,0 97,5% 106,0% 108,7% IPX5D
For the complete list of the option kits and of the flue system kits for VICTRIX 115 boiler see the second section of the catalogue. For the complete list of the option kits and of the flue system kits for VICTRIX 90 boiler see the second section of the catalogue.
98
• Heat output of 72,6 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Modulating heat output from 25 to 100%
• Possible indoor or outdoor installation
• Double NTC probe for optimum temperature control
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Possibility of installation in cascade (up to 8 appliances)
• Hydraulic options and flue systems for cascade installations(up to 3 appliances)
• Possibility to connect a separate storage tank unit
• Standard frost protection up to -5 °C
• Heat output of 50 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Modulating heat output from 20 to 100%
• Possible indoor or outdoor installation
• Double NTC probe for optimum temperature control
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Possibility of installation in cascade (up to 8 appliances)
• Hydraulic options and flue systems for cascade installations(up to 3 appliances)
• Possibility to connect a separate storage tank unit
• Standard frost protection up to -5 °C
LIG
HT
CO
MM
ER
CIA
L
LIG
HT
CO
MM
ER
CIA
L
VICTRIX 75 VICTRIX 50Wall-hung modular condensing boiler for heating only Wall-hung modular condensing boiler for heating only
Dimensions(H x W x P) mm
Empty appliance weight kg
950 x 600 x 525 68,0
Dimensions(H x W x P) mm
Empty appliance weight kg
950 x 600 x 525 63,0
The price of VICTRIX 75 boiler does not include the “Green Series” flue kit, to be ordered separately. The price of VICTRIX 50 boiler does not include the “Green Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only. For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS MAIN FLUE KITS
MAIN OPTIONS MAIN OPTIONS
Type Code
Terminal horizontal outlet kit Ø 80 3.015255
Terminal vertical outlet kit Ø 80 3.015256
Horizontal concentric kit Ø 80/125 3.015242
Type Code
Terminal horizontal outlet kit Ø 80 3.015255
Terminal vertical outlet kit Ø 80 3.015256
Horizontal concentric kit Ø 80/125 3.015242
Type Code
External probe 3.015266
Three-way valve kit 3.015223
Hydraulic manifold kit 3.015224
Type Code
External probe 3.015266
Three-way valve kit 3.015223
Hydraulic manifold kit 3.015224
Model CodeN.G.L.P.G.
Heat outputkW
Efficiency at nominal heat output
Protectionindex
80-60 °C 50-30 °C 40-30 °C
VICTRIX 75 3.0185113.018511GPL 72,6 97,3% 104,5% 107,0% IPX5D
Model CodeN.G.L.P.G.
Heat outputkW
Efficiency at nominal heat output
Protectionindex
80-60 °C 50-30 °C 40-30 °C
VICTRIX 50 3.0163593.016359GPL 50,0 98,5% 106,0% 107,0% IPX5D
For the complete list of the option kits and of the flue system kits for VICTRIX 75 boiler see the second section of the catalogue. For the complete list of the option kits and of the flue system kits for VICTRIX 50 boiler see the second section of the catalogue.
1110
• Heat outputs of 26 and 32 kW
• Wide liquid crystal backlit display
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Heat exchanger with high circulation
• 3 star marking of sanitary comfort
• Stainless steel storage tank with capacity of 54 litres
• Stainless steel condensing module
• Modulating heat output from 20 to 100%
• Modulating system pump
• Adjustable system by-pass
• Optimum seasonal performances thanks to thermoregulationoptions such as Super CAR, CARV2 and external probe
• Standard frost protection up to -5 °C
• Heat output of 26 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Stainless steel storage tank with capacity of 45 litres
• Modulating heat output from 12 to 100%
• Control panel with handy digital display and traditional knobs
• Adjustable system by-pass
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optional connection group
• Optimum seasonal performances thanks to thermoregulationoptions such as CARV2, CAR Universal and external probe
• Standard frost protection up to -5 °C
WA
LL-H
UN
G C
ON
DE
NS
ING
WA
LL-H
UN
G C
ON
DE
NS
ING
VICTRIX Zeus Superior kW VICTRIX ZeusWall-hung condensing boiler with built-in stainless steel storage tank of 54 litres
Wall-hung condensing boiler with built-in stainless steel storage tank of 45 litres
Model CodeN.G.L.P.G.
Heat output kW Storagetankcapacity
Efficiency at nominal heat output
Protectionindex
D.H.W. production(∆t 30 °C)
First ContinuousC.H. D.H.W. 80-60 °C 40-30 °C 10 min service
VICTRIX Zeus26 1 I
3.0203193.020319GPL 23,6 26,0 45 litres 96,9% 107,5% IPX4D 156 litres 12,4 l/min
Model CodeN.G.L.P.G.
Heat output kW Storagetankcapacity
Efficiency at nominal heat output
Sanitarycomfort(EN 13203-1)
Protectionindex
D.H.W. production(∆t 30 °C)
First ContinuousC.H. D.H.W. 80-60 °C 40-30 °C 10 min service
VICTRIX ZeusSuperior 26 kW
3.0191903.019190GPL 21,0 25,8 54 litres 96,7% 106,5% IPX5D 160 litres 13,1 l/min
VICTRIX ZeusSuperior 32 kW
3.0191913.019191GPL 32,0 32,0 54 litres 96,9% 107,3% IPX5D 192 litres 15,8 l/min
The price of VICTRIX Zeus 26 boiler does not include the “Green Series” flue kit, to be ordered separately.
The price of VICTRIX Zeus Superior kW boilers do not include the “Green Series” flue kit, to be ordered separately.
For the complete list of the option kits and of the flue system kits for VICTRIX Zeus Superior kW boiler see the second section of the catalogue.
For the complete list of the option kits and of the flue system kits for VICTRIX Zeus 26 boiler see the second section of the catalogue.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN FLUE KITS
MAIN OPTIONS
MAIN OPTIONS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
Connection kit 3.020505Type Code
Super CAR (modulating remote control) 3.016577
External probe 3.014083
Relay board kit 3.015350
Model Dimensions(H x W x P) mm
Empty appliance weight kg
26 kW 900 x 600 x 466 70,1
32 kW 900 x 600 x 466 72,8
Dimensions(H x W x P) mm
Empty appliance weight kg
870 x 580 x 380 61,3
1312
• Heat output of 32 kW
• Wide liquid crystal backlit display
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Heat exchanger with high circulation
• 3 star marking of sanitary comfort
• Modulating heat output from 20 to 100%
• “Aqua Celeris” patented system
• Modulating system pump
• Adjustable system by-pass
• Optimum D.H.W. performances thanks to the flow regulator
• Optimum seasonal performances thanks to thermoregulationoptions such as Super CAR, CARV2 and external probe
• Standard frost protection up to -3 °C
• Heat output of 32 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Heat exchanger with high circulation
• Modulating heat output from 20 to 100%
• Wide liquid crystal backlit display
• Pre-arranged for connection to Immerstor range
• Modulating system pump
• Adjustable system by-pass
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optimum seasonal performances thanks to thermoregulationoptions such as Super CAR, CARV2 and external probe
• Standard frost protection up to -3 °C
WA
LL-H
UN
G C
ON
DE
NS
ING
WA
LL-H
UN
G C
ON
DE
NS
ING
VICTRIX Superior kW VICTRIX Superior kW XWall-hung combi condensing boiler with “Aqua Celeris” Wall-hung condensing boiler for heating only
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Sanitarycomfort(EN 13203-1)
Protectionindex
D.H.W.production(∆t 30 °C)
80-60 °C 40-30 °C
VICTRIX Superior32 kW
3.0191033.019103GPL 32,0 98,0% 105,7% IPX5D 15,3 l/min
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Protectionindex
80-60 °C 40-30 °C
VICTRIX Superior32 kW X
3.0191043.019104GPL 32,0 98,0% 105,7% IPX5D
The price of VICTRIX Superior 32 kW X boiler does not include the “Green Series” flue kit, to be ordered separately.The price of VICTRIX Superior 32 kW boiler does not include the “Green Series” flue kit, to be ordered separately.
For the complete list of the option kits and of the flue system kits for VICTRIX Superior 32 kW boiler see the second section of the catalogue.
For the complete list of the option kits and of the flue system kits for VICTRIX Superior 32 kW X boiler see the second section of the catalogue.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITSMAIN FLUE KITS
MAIN OPTIONSMAIN OPTIONS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
Storage tank connection kit 3.019213
Type Code
Super CAR (modulating remote control) 3.016577
External probe 3.014083
Relay board kit 3.015350
Solar valve 3.018911
Dimensions(H x W x P) mm
Empty appliance weight kg
830 x 440 x 350 47,5
Dimensions(H x W x P) mm
Empty appliance weight kg
800 x 440 x 350 53,5
1514
• Heat output of 26 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Modulating heat output from 12 to 100%
• Control panel with digital display
• Compact dimensions
• Light weight
• Automatic system by-pass
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optional connection group
• Optimum seasonal performances thanks to thermoregulationoptions such as CARV2 and external probe
• Standard frost protection up to -5 °C
• Heat outputs of 24 and 12 kW
• High efficiency and low pollutant emissions thanks to condensingtechnology
• Control panel with digital display
• Compact dimensions
• Automatic system by-pass
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Possibility to connect the boiler to Immerstor range
• Optimum seasonal performances thanks to thermoregulationoptions such as CARV2, CAR Universal and external probe
• Standard frost protection up to -5 °C
• Optional connection group
VICTRIX VICTRIX XWall-hung compact combi condensing boiler Wall-hung compact condensing boiler for heating only
Model CodeN.G.L.P.G.
Heat output kW Efficiency at nominal heat output
Protectionindex
D.H.W.production(∆t 30 °C)
C.H. D.H.W. 80-60 °C 40-30 °C
VICTRIX 26 2 I 3.0221083.022108GPL 23,6 26,0 97,8% 108,1% IPX4D 12,4 l/min
The price of VICTRIX 26 boilers do not include the “Green Series” flue kit, to be ordered separately.
For the complete list of the option kits and of the flue system kits for VICTRIX 26 boiler see the second section of the catalogue.
For the complete list of the option kits and of the flue system kits for VICTRIX X boiler see the second section of the catalogue.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
The price of VICTRIX X boiler does not include the “Green Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN OPTIONS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
Connection kit 3.017495
Storage tank connection kit 3.022193
WA
LL-H
UN
G C
ON
DE
NS
ING
WA
LL-H
UN
G C
ON
DE
NS
ING
Dimensions(H x W x P) mm
Empty appliance weight kg
780 x 440 x 250 39,0
MAIN OPTIONS
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
Connection kit 3.017494
Solar valve 3.018911
Solar probe kit 3.021452
Model Dimensions(H x W x P) mm
Empty appliance weight kg
X 24 738 x 440 x 250 37,6
X 12 738 x 440 x 250 36,5
Model CodeN.G.L.P.G.
Heat output kW Efficiency at nominal heat output
Protectionindex
C.H. D.H.W. 80-60 °C 40-30 °C
VICTRIX X 24 2 I 3.0221093.022109GPL 23,6 26,0 97,8% 108,1% IPX4D
VICTRIX X 12 2 I 3.0221103.022110GPL 12,0 12,0 97,7% 107,0% IPX4D
1716
• Heat output of 24 kW
• High efficiency and low pollutant emissions thanks to condensing technology
• Designed for open heating systems
• Control panel with digital display
• Compact dimensions
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optimum seasonal performances thanks to thermoregulation options such as CARV2, CAR Universal and external probe
• Standard frost protection up to -5 °C
VICTRIX RWall-hung heating only condensing boiler, for open heating systems
The price of VICTRIX R boilers do not include the “Green Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
WA
LL-H
UN
G C
ON
DE
NS
ING
Dimensions(H x W x P) mm
Empty appliance weight kg
738 x 440 x 250 45,0
MAIN OPTIONS
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
For the complete list of the option kits and of the flue system kits for VICTRIX R boiler see the second section of the catalogue.
• Heat outputs of 24 and 30 kW
• Designed for high temperature heating systems
• Pre-arranged for functioning in multi-zone heating systems
• Control board equipped with functional knobs
• Automatic system by-pass
• Optional connection group
• Optimum seasonal performances thanks to thermoregulation options such as CARV2, CAR Universal and external probe
EOLO Extra kW HPWall-hung combi condensing boiler for outdoor installation, for high temperature systems
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Protectionindex
Frostprotection
D.H.W. production(∆t 30 °C)
C.H. D.H.W.
EOLO Extra 24 kW HP
3.0210373.021037GPL 24,0 24,0 97,3% IPX5D - 5 °C 11,5 l/min
EOLO Extra 30 kW HP
3.0210383.021038GPL 30,0 30,0 96,4% IPX5D - 5 °C 14,3 l/min
The price of EOLO Extra kW HP boilers do not include the “Green Series” flue kit, to be ordered separately.
For the complete list of the option kits and of the flue system kits for EOLO Extra kW HP boiler see the second section of the catalogue.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN OPTIONS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
Connection kit 3.019329
Anti-freeze protection (-15 °C) 3.017324
Model Dimensions(H x W x P) mm
Empty appliance weight kg
24 kW HP 710 x 520 x 250 35,0
30 kW HP 710 x 520 x 250 45,0
WA
LL-H
UN
G C
ON
DE
NS
ING
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Protectionindex
Frost protection
80-60 °C 40-30 °C
VICTRIX R 24 3.0191433.019143GPL 24,0 98,7% 107,7% IPX4D -5 °C
1918
• Heat outputs of 26 and 32 kW
• Wide liquid crystal backlit display
• High efficiency and low pollutant emissions thanksto condensing technology
• Stainless steel storage tank with capacity of 120 litresprearranged for solar panels connection
• 3 star marking of sanitary comfort
• Prearranged for zone systems and high/low temperature systems
• Modulating heating pumps with low power consumption
• ABT version factory fitted for mixed temperature systems
• Optimum seasonal performances thanks to thermoregulationoptions such as Super CAR, CARV2 and external probe
• Heat output of 26 kW
• High efficiency and low pollutant emissions thanksto condensing technology
• Wide liquid crystal backlit display
• Solar circuit included
• Stainless steel storage tank with capacity of 200 litres
• 3 star marking of sanitary comfort
• Pre-arranged for functioning in high/low temperature heating systems
• Pre-arranged for functioning in multi-zone heating systems
• Modulating heating pumps with low power consumption
• Optimum seasonal performances thanks to thermoregulation options such as Super CAR, CARV2 and external probe
FLO
OR
-STA
ND
ING
CO
ND
EN
SIN
G S
OLA
R S
YS
TE
M R
EA
DY
FLO
OR
-STA
ND
ING
CO
ND
EN
SIN
G
HERCULES Condensing HERCULES SolarFloor-standing condensing boiler with built-in stainless steel storage tank of 120 litres
Floor-standing condensing boiler with built-in stainless steel storage tank of 200 litres, solar system ready
Model CodeN.G.L.P.G.
Heat output kW Storagetankcapacity
Efficiency at nominal heat output
Protectionindex
D.H.W. production(∆t 30 °C)
First ContinuousC.H. D.H.W. 80-60 °C 40-30 °C 10 min service
HERCULES Solar 26 1A
3.0204753.020475GPL 23,6 26,0 200 litres 96,9% 107,5% IPX5D 190 litres 12,4 l/min
The price of HERCULES Solar 26 boilers do not include the “Green Series” flue kit, to be ordered separately.
For the complete list of the option kits and of the flue system kits for HERCULES Condensing boilers see the second section of the catalogue.
For the complete list of the option kits and of the flue system kits for HERCULES Solar 26 boiler see the second section of the catalogue.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN OPTIONS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
Type Code
Super CAR (modulating remote control) 3.016577
External probe 3.014083
Connection kit 3.020505
Solar connection kit 3.021382
Low temperature second zone kit 3.018836
High temperature second zone kit 3.018837
2 high temperature zones kit 3.018838
2 low temperature zones kit 3.020003
Model Dimensions(H x W x P) mm
Empty appliance weight kg
26 1600 x 600 x 600 126,6
32 1600 x 600 x 600 127,9
ABT 32 1600 x 600 x 600 130,1
The price of HERCULES Condensing boilers do not include the “Green Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN OPTIONS
Type Code
Horizontal concentric complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 3.018501
Twin pipes complete kit Ø 80/80 3.012002
Type Code
Super CAR (modulating remote control) 3.016577
External probe 3.014083
Low temperature second zone kit 3.018836
High temperature second zone kit 3.018837
2 high temperature zones kit 3.018838
2 low temperature zones kit 3.020003
Additional low temperature zone kit for ABT version 3.018839
Model CodeN.G.L.P.G.
Heat output kW Storagetankcapacity
Efficiency at nominal heat output
Protectionindex
D.H.W. production(∆t 30 °C)
First ContinuousC.H. D.H.W. 80-60 °C 40-30 °C 10 min service
HERCULESCondensing 26 2 E
3.0191963.019196GPL 23,9 25,8 120 litres 96,0% 106,5% IPX5D 199 litres 12,3 l/min
HERCULESCondensing 32 2 I
3.0191973.019197GPL 32,0 32,0 120 litres 96,9% 107,3% IPX5D 243 litres 15,3 l/min
HERCULESCondensing ABT 32 2 I
3.0191983.019198GPL 32,0 32,0 120 litres 96,9% 107,3% IPX5D 243 litres 15,3 l/min
Dimensions(H x W x P) mm
Empty appliance weight kg
1970 x 600 x 750 193,8
NEW
2120
• Sealed chamber fan assisted models with heat outputs of 24, 28 and 32 kW
• Integrated stainless steel storage tank with capacity of 60 litres
• Heat exchanger with high circulation
• 3 star marking of sanitary comfort
• 2 litre sanitary expansion vessel
• Adjustable system by-pass
• Self-adaptable fan
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optimum seasonal performances thanks to thermoregulationoptions such as Super CAR, CARV2 and external probe
• Standard frost protection up to -5 °C
WA
LL-H
UN
G T
RA
DIT
ION
AL
WA
LL-H
UN
G T
RA
DIT
ION
AL
ZEUS Superior kWWall-hung traditional boiler with built-in stainless steel storage tank of 60 litres
For the complete list of the option kits and of the flue system kits for ZEUS Superior kW boilers see the second section of the catalogue. For the complete list of the option kits and of the flue system kits for AVIO kW and ZEUS kW boilers see the second section of the catalogue.
Model Dimensions(H x W x P) mm
Empty appliance weight kg
24 kW 900 x 600 x 450 66,1
28 kW 900 x 600 x 450 68,0
32 kW 900 x 600 x 450 70,2
Model Dimensions(H x W x P) mm
Empty appliance weight kg
AVIO 24 kW 900 x 580 x 380 50,0
ZEUS 24 kW 890 x 580 x 380 54,0
ZEUS 28 kW 890 x 580 x 380 58,0
The price of ZEUS Superior kW boilers do not include the “Blue Series” flue kit, to be ordered separately. The price of ZEUS kW boilers does not include the ”Blue Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only. For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only.
MAIN FLUE KITS MAIN FLUE KITS
MAIN OPTIONS MAIN OPTIONS
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Type Code
Super CAR (modulating remote control) 3.016577
External probe 3.014083
Additional system expansion vessel 3.018433
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
D.H.W. expansion vessel 3.017744
Model CodeN.G.L.P.G.
Heat output kW
Storagetankcapacity
Efficiency at nominal heat output
Sanitarycomfort(EN 13203-1)
Protectionindex
D.H.W. production(∆t 30 °C)
First Continuous10 min service
ZEUS Superior 24 kW 3.0185083.018508GPL 24,0 60 litres 93,7% IPX5D 153 litres 11,5 l/min
ZEUS Superior 28 kW 3.0185093.018509GPL 28,0 60 litres 93,9% IPX5D 166 litres 13,4 l/min
ZEUS Superior 32 kW 3.0185103.018510GPL 31,7 60 litres 94,3% IPX5D 189 litres 15,1 l/min
Model CodeN.G.L.P.G.
Heat output kW
Storagetankcapacity
Efficiency at nominal heat output
Open chamber conventional flue
Sealed chamberfan assisted
Protectionindex
D.H.W. production(∆t 30 °C)
First Continuous10 min service
AVIO 24 kW 3.0185053.018505GPL 23,7 45 litres 90,4% • IPX4D 135 litres 11,3 l/min
ZEUS 24 kW 3.0185063.018506GPL 24,0 45 litres 94,1% • IPX4D 135 litres 11,5 l/min
ZEUS 28 kW 3.0185073.018507GPL 28,0 45 litres 93,9% • IPX4D 145 litres 13,4 l/min
• Heat outputs of 24 and 28 kW
• Open chamber conventional flue model (AVIO) or sealed chamberfan assisted models (ZEUS)
• Integrated stainless steel storage tank with capacity of 45 litres
• Compact dimensions
• Adjustable system by-pass
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optimum seasonal performances thanks to thermoregulatingoptions such as CARV2, CAR Universal and external probe
• Standard frost protection up to -5 °C
AVIO/ZEUS kWWall-hung traditional boiler with built-in stainless steel storage tank of 45 litres
2322
• Sealed chamber fan assisted models with heat outputs of 24, 28 and 32 kW
• New modern design
• “Aqua Celeris” patented system
• Approved for indoor and outdoor installation in partiallyprotected areas
• Adjustable system by-pass
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optimum seasonal performances thanks to thermoregulatingoptions such as CARV2, CAR Universal and external probe
• Optional connection group
• Standard frost protection up to -5 °C
WA
LL-H
UN
G T
RA
DIT
ION
AL
WA
LL-H
UN
G T
RA
DIT
ION
AL
MAIOR EOLOWall-hung combi traditional boiler with “Aqua Celeris”
For the complete list of the option kits and of the flue system kits for MAIOR EOLO boilers see the second section of the catalogue.
For the complete list of the option kits for NIKE Mini 28 kW Special boiler see the second section of the catalogue.
Model Dimensions(H x W x P) mm
Empty appliance weight kg
24 751 x 440 x 340 41,5
28 751 x 440 x 340 41,9
32 751 x 440 x 340 42,4
Dimensions(H x W x P) mm
Empty appliance weight kg
740 x 450 x 310 31,0
The price of MAIOR EOLO boilers does not include the “Blue Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN OPTIONS
MAIN OPTIONS
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
Solar valve 3.018911
Connection kit 3.021453
Solar probe kit 3.021452
Type Code
CARV2 (modulating remote control) 3.021395
External probe 3.014083
Connection kit 3.016671
Solar valve 3.018911
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Sealed chamberfan assisted
Protectionindex
D.H.W. production(∆t 30 °C)
MAIOR EOLO 24 4 E
3.0209223.020922GPL 24,0 93,0% • IPX5D 11,5 l/min
MAIOR EOLO 28 4 E
3.0209233.020923GPL 28,0 94,3% • IPX5D 13,4 l/min
MAIOR EOLO 32 4 E
3.0209243.020924GPL 32,0 93,5% • IPX5D 15,3 l/min
• Open chamber conventional flue model with heat output of 28 kW
• Compact dimensions
• Functioning information and diagnostic by LED
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Compact hydraulic group with automatic system by-pass
• Domestic hot water stainless steel heat exchanger
• Possible connection to CARV2, CAR Universal and external probe
• Optional connection group
• Standard frost protection up to -5 °C
NIKE Mini 28 kW SpecialWall-hung combi traditional boiler open chamber and conventional flue
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Open chamber conventional flue
Protectionindex
D.H.W. production(∆t 30 °C)
NIKE Mini 28 kW Special
3.0189213.018921GPL 27,9 90,3% • IPX4D 13,3 l/min
2524
WA
LL-H
UN
G T
RA
DIT
ION
AL
WA
LL-H
UN
G T
RA
DIT
ION
AL
• Heat output of 24 kW
• Open chamber conventional flue models (NIKE) or sealed chamberfan assisted models (EOLO)
• New modern design and compact dimensions
• Digital display
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Pre-arranged for connection to Immerstor range
• Adjustable by-pass
• Possible connection to CARV2, CAR Universal and external probe
• Optional connection group
• Standard frost protection up to -5 °C
MINI NIKE/EOLO XWall-hung compact traditional boiler for heating only
For the complete list of the option kits and of the flue system kits for MINI NIKE/EOLO X boilers see the second section of the catalogue.
Model Dimensions(H x W x P) mm
Empty appliance weight kg
NIKE X 24 755 x 440 x 240 25,5
EOLO X 24 751 x 440 x 240 31,4
The price of MINI EOLO X 24 boiler do not include the “Blue Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only.
MAIN FLUE KITS (only for EOLO model)
MAIN OPTIONS
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Type Code
CARV2 (modulating remote control) 3.021395
Connection kit 3.015229
Storage tank connection kit 3.020934
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Open chamber conventional flue
Sealed chamberfan assisted
Protectionindex
MINI NIKE X 24 3 E 3.0208573.020857GPL 23,8 91,0% • IPX4D
MINI EOLO X 24 3 E 3.0208553.020855GPL 24,0 93,6% • IPX5D
• Heat outputs of 24 and 28 kW
• Open chamber conventional flue model (NIKE) or sealed chamberfan assisted models (EOLO)
• New modern design and compact dimensions
• Digital display
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Compact hydraulic group with adjustable system by-pass
• Domestic hot water stainless steel heat exchanger
• Possible connection to CARV2, CAR Universal and external probe
• Optional connection group
• Standard frost protection up to -5 °C
MINI NIKE/EOLOWall-hung compact combi traditional boiler
For the complete list of the option kits and of the flue system kits for MINI NIKE/EOLO boilers see the second section of the catalogue.
Model Dimensions(H x W x P) mm
Empty appliance weight kg
NIKE 24 755 x 440 x 240 26,1
EOLO 24 751 x 440 x 240 32,0
EOLO 28 751 x 440 x 340 38,0
The price of MINI EOLO boilers do not include the “Blue Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN OPTIONS
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Type Code
CARV2 (modulating remote control) 3.021395
Connection kit for 24 kW model 3.015229
Connection kit for 28 kW model 3.021453
Anti-scale kit 3.016305
Solar valve 3.018911
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominalheat output
Open chamber conventional flue
Sealed chamberfan assisted
Protectionindex
D.H.W. production(∆t 30 °C)
MINI NIKE 24 3 E 3.0208523.020852GPL 23,8 91,0% • IPX4D 11,4 l/min
MINI EOLO 24 3 E 3.0208533.020853GPL 24,0 93,6% • IPX5D 11,5 l/min
MINI EOLO 28 3 E 3.0208563.020856GPL 28,0 94,3% • IPX5D 13,4 l/min
2726
WA
LL-H
UN
G T
RA
DIT
ION
AL
WA
LL-H
UN
G T
RA
DIT
ION
AL
For the complete list of the option kits and of the flue system kits for Star boilers see the second section of the catalogue.
Model Dimensions(H x W x P) mm
Empty appliance weight kg
NIKE Star 24 751 x 440 x 240 24,6
EOLO Star 24 756 x 440 x 240 29,0
The price of EOLO Star boilers do not include the ”Blue Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only.
* This remote control is combinable esclusively with single zone systems.
MAIN FLUE KITS
MAIN OPTIONS
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Type Code
Mini CRD (Mini Digital Remote Control)* 3.020167
Connection kit 3.015229
Solar valve 3.018911
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Open chamber conventional flue
Sealed chamberfan assisted
Protectionindex
D.H.W. production(∆t 30 °C)
NIKE Star 24 3 E 3.0194793.019479GPL 23,6 91,1% • IPX4D 11,3 l/min
EOLO Star 24 3 E 3.0194803.019480GPL 23,8 93,4% • IPX5D 11,4 l/min
• Open chamber conventional flue model (NIKE) and sealed chamberfan assisted model (EOLO), both with heat output of 24 kW
• Compact dimensions
• Digital display
• Bithermal heat exchanger for heating and fast domestic hot waterproduction
• Adjustable by-pass
• Electronic ignition and modulation
• Electronic control board microprocessor driven
• Optional connection group
• Possible connection to CARV2, CAR Universal and Mini CRD(Mini Digital Remote Control)
• Standard frost protection up to -5 °C
NIKE/EOLO StarWall-hung combi traditional boiler with bithermal heat exchanger
For the complete list of the option kits and of the flue system kits for EOLO Extra kW boilers see the second section of the catalogue.
Model Dimensions(H x W x P) mm
Empty appliance weight kg
24 kW 730 x 440 x 240 43,5
28 kW 730 x 520 x 250 44,0
32 kW 730 x 520 x 250 44,5
Model CodeN.G.L.P.G.
Heat output kW
Efficiency at nominal heat output
Sealed chamberfan assisted
Protectionindex
D.H.W. production(∆t 30 °C)
EOLO Extra 24 kW 3.0189253.018925GPL 24,0 92,8% • IPX5D 11,5 l/min
EOLO Extra 28 kW 3.0189243.018924GPL 28,0 93,0% • IPX5D 13,4 l/min
EOLO Extra 32 kW 3.0203793.020379GPL 32,0 93,2% • IPX5D 15,3 l/min
• Sealed room fan assisted models with 24, 28 and 32 kWheat outputs
• Amico Remote Control as standard
• Installable outdoors in open spaces thanks to the optional cover kit
• Compact dimensions
• Automatic system by-pass
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Connectable to the optional external probe
• Optional connection group
• Standard frost protection up to -15 °C
EOLO Extra kWWall-hung combi traditional boiler for outdoor installation
The price of EOLO Extra kW boilers does not include the “Blue Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
MAIN OPTIONS
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Type Code
External probe 3.014083
Connection kit for 24 kW model 3.019335
Connection kit for 28/32 kW model 3.019329
Cover kit for 24 kW model 3.016304
Cover kit for 28/32 kW model 3.016022
2928
• Heat outputs of 20,1 kW (JULIUS 11) and 24,4 kW (JULIUS 14)
• New essential design
• Modulating gas valve
• Battery-run electronic ignition
• Chimney safety device
CO
Mb
I W
AT
ER
HE
AT
ER
S
CO
Mb
I W
AT
ER
HE
AT
ER
S
JULIUSWall-hung combi water heater open chamber and conventional flue
Model Dimensions(H x W x P) mm
Empty appliance weight kg
CAESAR 14 630 x 375 x 250 22,0
Super CAESAR 17 630 x 420 x 250 23,0
Model Dimensions(H x W x P) mm
Empty appliance weight kg
11 630 x 350 x 230 11,1
14 630 x 350 x 230 13,0
The price of CAESAR water heaters does not include the “Blue Series” flue kit, to be ordered separately.
For good performance and safe operation use Immergas “Blue Series” pipes and terminal flue outlet only.
MAIN FLUE KITS
Type Code
Horizontal concentric kit Ø 60/100 3.017736
Twin pipes complete kit Ø 80/80 3.010351
Horizontal outlet fan assisted Ø 80 3.011279
Model CodeN.G.L.P.G.
Heat output kW
Open chamber conventional flue
Batteryelectronicignition
Flamemodulation
D.H.W. production(∆t 25 °C)
JULIUS 11 3 E 3.0220083.022008GPL 20,1 • • • 11,5 l/min
JULIUS 14 3 E 3.0220093.022009GPL 24,4 • • • 14,0 l/min
Model CodeN.G.L.P.G.
Heat output kW
Sealedchamber fanassisted
Electronicignition
Flamemodulation
D.H.W. production(∆t 25 °C)
CAESAR 14 3 E 3.0220103.022010GPL 24,4 • • • 14,0 l/min
Super CAESAR 17 3 E 3.0220113.022011GPL 29,8 • • • 17,0 l/min
• Heat outputs of 24,4 kW (CAESAR 14) and 29,8 kW (SuperCAESAR 17)
• New control panel with LCD display
• Possible installation indoors or outdoors in partially protected areas
• Electronic control board microprocessor driven
• Electronic ignition and modulation
• Optional frost protection up to -15 °C
CAESAR 14Super CAESAR 17Wall-hung combi water heaters sealed chamber and fan assisted
nEW nEW
MAIN OPTIONS
Type Code
Anti-scale kit 3.014114
Gas pressure regulation kit 3.014607
90° gas valve 3.014145
MAIN OPTIONS
Type Code
Anti-scale kit 3.014114
-15 °C anti-freeze protection 3.014113
90° gas valve 3.014145
Thermostatic mixing valve 3.019099
3130
• Stainless steel storage tank units with capacity of 80, 120 and 200 litres
• New design
• Pre-arranged for D.H.W. recirculation
• UB Inox 120-2 and UB Inox 200-2 models pre-arranged for solar panels connection and for solar unit
• Inspection flange
• D.H.W. expansion vessel fitted as standard
• Built-in NTC probe
• Less heat losses thanks to improved insulation
• Solar unit standard fitted on the UB Inox Solar 200-2
MU
LTI
SY
ST
EM
DIS
TR
IbU
TIO
N M
AN
IFO
LDS
ST
OR
AG
E T
AN
KS
IMMERSTORStainless steel storage tanks
Model Description Code
DIMV2 BASICKit for system requiring high water flow rates
Hydraulic manifold and 1 pump 3.020536
DIMV2 2 ZONESKit for 2 zone systems Hydraulic manifold, 2 pumps and electronic board 3.021465
DIMV2 3 ZONESKit for 3 zone systems Hydraulic manifold, 3 pumps and electronic board 3.021466
DIMV2 H-LTKit for mixed systems with 1 low temperature zone and 1 high temperature zone
Hydraulic manifold, 2 pumps, 1 mixing valve and electronic board 3.021467
DIMV2 H-2LTKit for mixed systems with 2 low temperature zones and 1 high temperature zone
Hydraulic manifold, 3 pumps, 1 mixing valve and electronic board 3.021468
Model Code Capacitylitres
Height(mm)
Width(mm)
Depth(mm)
Expansion vesselcapacitylitres
8 bar safety valve
UB Inox 80-2 3.022012 80 850 550 550 4 •
UB Inox 120-2 3.022013 120 850 650 650 5 •
UB Inox 200-2 3.022014 200 1250 650 650 8 •
UB Inox Solar 200-2 3.022015 200 1250 600 600 8 •
• Kits for the management of heating systems divided into differentzones, heating systems with high/low temperature and heatingsystems with high flow rates
• Available in 5 different models
• Equipped with 3 speed traditional pumps
• No-return valve for each zone
• Easy recessed installation (19 cm deep only) or wall-hung
• Possible setting of the mixed zones (H-LT versions) up to 75 °C
• Pump locking by SILENT BLOCK system for a bettersilent functioning
DIMV2Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows
MAIN OPTIONS
Type Code
External probe 3.014083
By-pass for low temperature zones DIMV2 H-LT and DIMV2 H-2LT 3.021469
Low temperature zones safety kit 3.013794
Shut-off knobs 3.014948
nEWModel Dimensions
(H x W x P) mmEmpty appliance weight kg
BASIC 700 x 450 x 190 12,5
2 ZONES 700 x 450 x 190 17,3
3 ZONES 700 x 450 x 190 19,8
H-LT 700 x 450 x 190 19,7
H-2LT 700 x 450 x 190 23,2
MAIN OPTIONS
Type Code
Solar unit for UB Inox 120-2 and 200-2 3.019097
Electronic anode 3.020344
Solar panel connection kit for UB Inox 200-2 3.022195
Solar panel connection kit for UB Inox 200-2 in parallel 3.022196
Solar panel connection kit for UB Inox 120-2 3.022197
Connection kit for UB Inox 200-2 in parallel 3.022212
UB Inox 80-2 recirculation kit 3.022198
UB Inox 120-2 and 200-2 recirculation kit 3.022199
UB Inox Solar 200-2 recirculation kit 3.022200
UB Inox 200-2 in parallel recirculation kit 3.022201
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
INTEGRATED SOLUTION – stainless steel storage tank and solar circuit included
3332
• Kits for the management of heating systems divided in differentzones, heating systems with high/low temperature and heatingsystems with high flow rates
• Available in 5 different models
• Energy saving thanks to modulating type low electricconsumption class A pumps
• No-return valve for each zone
• Easy recessed installation (19 cm deep only) or wall-hung
• Possible setting of the mixed zones (H-LT versions) up to 75 °C
“GR
EE
N S
ER
IES
” FL
UE
SY
ST
EM
S
MU
LTI
SY
ST
EM
DIS
TR
IbU
TIO
N M
AN
IFO
LDS
DIMV2 TOPMultisystem distribution manifolds for the management of zone systems and systems requiring great water flows. High energetic efficiency thanks to class A pumps
Model Description Code
DIMV2 TOP 2 ZONESKit for 2 zone systems Hydraulic manifold, 2 low consumption pumps and electronic board 3.020534
DIMV2 TOP 3 ZONESKit for 3 zone systems Hydraulic manifold, 3 low consumption pumps and electronic board 3.020499
DIMV2 TOP H-LTKit for mixed systems with 1 low temperature zone and 1 high temperature zone
Hydraulic manifold, 2 low consumption pumps, 1 mixing valve and electronic board 3.020521
DIMV2 TOP H-2LTKit for mixed systems with 2 low temperature zones and 1 high temperature zone
Hydraulic manifold, 3 low consumption pumps, 1 mixing valve and electronic board 3.020361
MAIN OPTIONS
Type Code
External probe 3.014083
Low temperature zones safety kit 3.013794
Shut-off knobs 3.014948
Description Open chamber fan assisted installation (B23 type) Code
Horizontal kit Ø 80 (to discharge in the chimney) 3.015254
Terminal horizontal outlet kit Ø 80(to discharge horizontally) 3.015255
Terminal vertical outlet kit Ø 80 3.015256
4 extension pipes Ø 80 kit 0,5 m long 3.014642
4 extension pipes Ø 80 kit 1 m long 3.012088
1 extension pipe Ø 80 2 m long 3.016837
4 x 90° bends Ø 80 kit 3.012091
45° bend Ø 80 kit 3.012092
“Green Series” flue systems
All light commercial VICTRIX models are standard provided in B23 configuration (open chamber, fan assisted) but they can work also as sealed chamber fan assisted (C type) using the special kits supplied by Immergas. To correctly install the boiler, it is necessary to use the original Immergas “Green Series” flue systems; these components and accessories are specially designed to guarantee higher resistance to corrosion and fast and easy installation, thanks also to the push-fit assembly and special gasket seals.
VICTRIX 50/75/90/115 FLUE SYSTEMS
Flue components for condensing boilers
Model Dimensions(H x W x P) mm
Empty appliance weight kg
2 ZONES 700 x 450 x 190 17,3
3 ZONES 700 x 450 x 190 19,8
H-LT 700 x 450 x 190 19,7
H-2LT 700 x 450 x 190 23,2
3534
Description Sealed chamber fan assisted installation (C type) Code
Horizontal concentric kit Ø 80/125 3.015242
Vertical concentric kit Ø 80/125 3.015243
Flashing kit Ø 80/125 for flat roof 3.015249
Extension pipe kit Ø 80/125 2 m long 3.015246
Extension pipe kit Ø 80/125 1 m long 3.018667
87° bend kit Ø 80/125 3.015247
2 x 45° bend kit Ø 80/125 3.015248
“GR
EE
N S
ER
IES
” FL
UE
SY
ST
EM
S
“GR
EE
N S
ER
IES
” FL
UE
SY
ST
EM
S
In case of cascade systems in B23 configuration (open chamber, fan assisted), it is necessary to use a special flue manifold with a non-return device (flue locks) supplied by Immergas, so that the combustion products of one working boiler do not interfere with the combustion circuit of the not working boilers.
Description Code
Exhaust manifold kit with flue lock Ø 200 with adapterfor the additional boiler
For VICTRIX 115
3.020954
Exhaust manifold kit with flue locks Ø 125 for 2 boilersin cascade (including a condense draining siphon)
For VICTRIX 50
3.015240
Exhaust manifold kit with flue locks Ø 160 for 2 boilersin cascade (including a condense draining siphon)
For VICTRIX 75/90/115
3.020476
Exhaust manifold kit with flue lock Ø 125for the additional boiler
For VICTRIX 50
3.015241
Exhaust manifold kit with flue lock Ø 160for the additional boiler
For VICTRIX 75/90
3.020701
Extension pipe Ø 125 kit 0,5 m long for flue manifold
For VICTRIX 503.016370
Extension pipe Ø 125 kit 1 m long for flue manifold
For VICTRIX 503.016371
Extension pipe Ø 125 kit 2 m long for flue manifold
For VICTRIX 503.015250
90° bend kit Ø 125 mm for flue manifold
For VICTRIX 503.016179
2 x 45° bend kit Ø 125 mm for flue manifold
For VICTRIX 503.016180
Adapter Ø 125/160 for flue manifold
For VICTRIX 503.016215
FLUE SYSTEMS FOR VICTRIX 50/75/90/115 CASCADE INSTALLATION
Description Code
Gasket kit Ø 80 (10 pcs.) 3.015343
Gasket kit Ø 110 3.015344
Gasket kit Ø 125 3.015345
GASKET KITS FOR VICTRIX 50/75/90/115 FLUE SYSTEMS
3736
Description Code
Concentric horizontal complete kit Ø 60/100 3.012000
Concentric vertical complete kit Ø 60/100 (red ocher colour) 3.016833
Concentric vertical complete kit Ø 60/100 (black colour) 3.018501
Concentric horizontal outlet Ø 60/100 3.016836
Flanged stub-pipe kit Ø 60/100 3.012086
Extension pipe kit Ø 60/100 1 m long 3.012089
Extension pipe kit Ø 60/100 0,5 m long 3.014643
90° bend Ø 60/100 kit 3.012093
90° bend Ø 60/100 kit with inspection hole 3.016174
45° bend Ø 60/100 kit 3.012095
10 gasket kit Ø 60 (5 bend gaskets and 5 extension gaskets) 3.015376
Gasket kit for flange Ø 60/100 3.015379
Description Code
Twin pipes complete kit 3.012002
Terminal vertical outlet kit Ø 80 3.015256
Anti-wind vertical terminal kit Ø 80 3.021721
Horizontal outlet terminal Ø 80 3.016363
Flanged stub-pipe Ø 80 for flue discharge 3.016364
Flanged stub-pipe kit Ø 80 3.012087
Flanged stub-pipe + bend + extension pipe Ø 80for flue discharge 3.016365
4 extension pipes Ø 80 kit 0,5 m long 3.014642
4 extension pipes Ø 80 kit 1 m long 3.012088
1 extension pipe Ø 80 2 m long 3.016837
4 x 90° bends Ø 80 kit 3.012091
45° bend Ø 80 kit 3.012092
10 gasket kit Ø 80 (5 bend gaskets and 5 extension gaskets) 3.015378
“GR
EE
N S
ER
IES
” FL
UE
SY
ST
EM
S
“GR
EE
N S
ER
IES
” FL
UE
SY
ST
EM
S
The “Green Series” kits are exclusively made for condensing boilers and they are manufactured in PPS in order to guarantee high resistance to corrosion and allow quick and functional installation, thanks also to the simple coupling system adopted and to the use of special seals. To ensure correct installation of Immergas condensing boilers, the air inlet/flue outlet pipes kit must be selected from the Immergas “Green Series” shown here. These components - except for the C6 type - are provided and guaranteed by the boiler’s constructor.
FLUE SYSTEM FOR CONDENSING bOILERS < 35 kW Ø 60/100 FLUE SYSTEM FOR CONDENSING bOILERS < 35 kW Ø 80/80
Description Code
Cover kit for VICTRIX 26, VICTRIX X 24/X 12 3.017330
Cover kit for VICTRIX Superior 32 kW/32 kW X 3.017209
Cover kit for EOLO Extra kW HP 3.016022
COVER KITS
Description Code
HERCULES Condensing B22/B23 terminal kit 3.020004
ADDITIONAL KITS
3938
“GR
EE
N S
ER
IES
” Fl
uE
Sy
St
Em
S
“GR
EE
N S
ER
IES
” Fl
uE
Sy
St
Em
S
Ø 60 mm ducting systemFor condensing boilers of rated power lower than 35 kW (except EOLO Extra kW HP)
The Immergas Ø 60 mm ducting system can be used only with Immergas condensing boilers.Thanks to its particularly small diameter, the system can be routed without difficulty through already existing narrow chimney stacks, with the advantage that the installation of a gas fired system can be completed with remarkable simplicity and maximum efficiency.The system is installed by assembling all the components provided in single kits, which are each time necessary.The ducting system solution allows the use of domestic space heating not only through existing narrow chimney stacks but also of vertical expanded spaces with closed perimeter.From the installation point of view this provides a particularly rapid solution for lining an existing but unsuitable chimney stack; a 90° elbow is connected to the boiler flue outlet, and the new liner then made up using as many straight Ø 60 mm extension as are needed, finishing at the top with flue terminal.The pipes are closed through “clamps” alternated with spacer closing bands that, thanks to their expansion tongues, allow the pipe to stay in the middle of the chimney.
Immergas guarantee its ducting system according to the updated technical regulation, on condition that it is installed following the installation safety rules. The installation has to be effected in conformity with the assembling instruction provided by the manufacturers.
ImmERGAS GuARANtEE
Description Code
Vertical outlet kit for duct system Ø 60(vertical concentric exhaust flue terminal Ø 60and chimney closing panel)
3.012112
Push-fitting extension pipes kit 1 m for duct system Ø 60(4 extension pipes Ø 60 2 m long) 3.012144
Push-fitting extension pipes kit 2 m for duct system Ø 60(1 extension pipe Ø 60 2 m long) 3.013869
Pipe clamp kit for duct system Ø 60(5 pipe clamps Ø 60) 3.012145
Spacer pipe clamp kit for duct system Ø 60(3 spacer pipe clamps Ø 60) 3.012146
Hanging bracket kit(adjustable support chimney hanging bracket) 3.011600
Support band kit for duct system Ø 60(support bend Ø 60, bend locking collar, clamp,reduction Ø 80 - Ø 60)
3.012153
Chimney hole closing panel(hole closing panel, inspection door and grommet) 3.012008
90° bend Ø 60 for duct system1 bend 90° Ø 60 3.013870
4140
“GR
EE
N S
ER
IES
” Fl
uE
Sy
St
Em
S
“GR
EE
N S
ER
IES
” Fl
uE
Sy
St
Em
S
Ø 80 mm flexible ducting systemFor condensing boilers
Immergas also offers a specific Ø 80 mm flexible ducting system for its condensing boilers, including VICTRIX 50 model. This system, made in PP, is particularly suitable for lining existing chimney and flue stacks (or shafts) that are not perfectly straight, where a rigid ducting system could in some cases be difficult to install. In effect, the flexibility of the duct allows installation even in chimneys with significant misalignments.The flexible pipe is the essential element of the system and it is a sole component 12 meters long.Depending on the particular installation, this component can either be cut to size or, for rises in excess of 12 meters, extended with a special flexible -to-flexible adapter kit. The flexible pipe has no joins, a feature which together with the lightness of the system as a whole, signifies extreme versatility of use as well as notable ease of installation.From the installation point of view, the connection to the boiler flue outlet is made with an 87° x Ø 80 mm bend; this is then connected to the duct at the bottom of the run, and the flue terminal to the top.The flexible duct is anchored to the inside wall of the chimney stack by means of a metal ring and spider; it is also connected rigidly to the bend at the bottom by way of a special adapter, and to the flue terminal at the top.Once installed, the flue duct can be inspected from the bottom end, by way of the flap provided.
Installers should note that 80 mm is the nominal diameter of the flexible duct (in practice, the external diameter is 89,5 mm).
The whole ducting system concerns the first 5 kits shown in these pages. The adapting kit F/F is necessary only if 2 parts have to be joined with connecting 2 flexible pipes.
Immergas guarantee its ducting system according to the updated technical regulation, on condition that it is installed following the installation safety rules. The installation has to be effected in conformity with the assembling instruction provided by the manufacturers.
ImmERGAS GuARANtEE
Description Code
Flexible duct kit Ø 80 mm, L=12 m + 4 centering spacer 3.014170
Kit support components for flexible ducting system 3.014171
Vertical outlet kit Ø 80/125 for flexible ducting system 3.014174
Valley kit for flexible ducting system 3.014173
Chimney hole closing panel kit 3.012008
Adapter F/F 3.014172
4342
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
Description Code
Concentric horizontal complete kit Ø 60/100 3.017736
Concentric horizontal complete kit Ø 60/100 3.014147
Concentric horizontal anti-freeze complete kit Ø 60/100 3.018210
Concentric vertical outlet Ø 60/100 (red ocher color)
To be combined with the flanged stub-pipe for vertical outlet(Code 3.011141)
3.015631
Horizontal outlet Ø 60/100 3.011572
Flanged stub-pipe Ø 60/100 vertical outlet 3.011141
Flanged bend Ø 60/100 3.011139
1 extension pipe Ø 60/100 0,3 m long with inspection hole 3.014418
1 extension pipe Ø 60/100 0,5 m long 3.018278
1 extension pipe Ø 60/100 1 m long 3.018277
1 extension pipe Ø 60/100 2 m long 3.010739
90° bend Ø 60/100 3.010949
90° bend Ø 60/100 with inspection hole 3.016172
45° bend Ø 60/100 3.010950
Condense tank kit Ø 60/100 3.016173
“Blue Series” flue systems
The “Blue Series” kits are exclusively made for traditional boilers and they are manufactured in aluminium in order to guarantee high resistance and allow quick and functional installation, thanks also to the simple coupling system adopted and to the use of special seals. To ensure correct installation of Immergas traditional boilers, the air inlet/flue outlet pipes kit must be selected from the Immergas “Blue Series” shown here.
FluE SyStEm FOR tRADItIONAl BOIlERS Ø 60/100
Flue components for traditional boilers and water heatersDescription Code
Twin pipes complete kit Ø 80/80 3.010351
Twin pipes complete kit Ø 80/80 insulated 3.010233
Vertical flue outlet for twin pipes Ø 80 3.010963
Wind-stop outlet 3.011488
Flanged stub-pipes Ø 80 3.011570
4 extension pipes Ø 80 0,5 m long 3.011491
4 extension pipes Ø 80 1 m long 3.010741
1 extension pipe Ø 80 2 m long 3.011167
1 insulated extension pipe Ø 80 1 m long 3.010947
1 insulated extension pipe Ø 80 2 m long 3.010948
4 x 90° bend Ø 80 kit 3.010955
90° bend Ø 80 with inspection hole 3.016175
FluE SyStEm FOR tRADItIONAl BOIlERS Ø 80/80
4544
Description Code
45° bend Ø 80 kit 3.010956
Insulated 90° bend Ø 80 kit 3.010953
Insulated 45° bend Ø 80 kit 3.010954
Female/female 90° bend Ø 80 3.011571
Female/female stub-pipe Ø 80 3.012714
Condense tank kit Ø 80 3.012009
Flue outlet wind-stop grate Ø 80 3.010962
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
Description Code
Adapter Ø 60/100 - 80/125 3.010957
Concentric horizontal complete kit Ø 80/125 3.010526
Concentric vertical complete kit Ø 80/125 3.010352
1 extension pipe Ø 80/125 0,5 m long 3.011157
1 extension pipe Ø 80/125 1 m long 3.010945
1 extension pipe Ø 80/125 2 m long 3.010946
90° bend Ø 80/125 3.010951
90° bend Ø 80/125 with inspection hole 3.016171
45° bend Ø 80/125 3.010952
Condense tank kit Ø 80/125 3.010960
FluE SyStEm FOR tRADItIONAl BOIlERS Ø 80/125
4746
Description Code
10 gasket kit Ø 60(5 bend gaskets and 5 extension gaskets) 3.011143
10 gasket kit Ø 80 3.011144
10 gasket kit Ø 100 3.011145
10 gasket kit Ø 125 3.011146
Wall sealing plate Ø 125 (2 pieces) 3.010958
Wall sealing plate Ø 100 (2 pieces) 3.010959
Wall sealing plate Ø 80 (2 pieces) 3.010996
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
ADDItIONAl KItS FOR tRADItIONAl BOIlERS
Type Code
Condense tank kit Ø80 3.012009
1
2 3
Ø 80 mm ducting systemFor traditional boilers
The system consists in a series of components, supplied as individual kits, which can be assembled in 3 different configurations:1 tWO-tEE ducting system2 ONE-tEE ducting system3 Ducting system WItH INlEt BENDIn every configuration the pipes of the ducting system can be positioned, apart from existing chimneys, also in shaft without good development and with close perimeter.
1 tWO-tEE ducting systemWith this solution the ducting system pipes are fitted into a TEE connection, in order to connect:• The boiler, coupled to the horizontal leg• A second tee element, with a respective inspection flap, located at a convenient height below the boilerThis system allows easy inspection of the flue and includes a special condensate collector kit to which a drain line can be connected.
2 ONE-tEE ducting systemIn this configuration, the pipes of the ducting system end at the bottom with a TEE, of which the horizontal leg is connected to the boiler. The vertical bottom leg of the TEE incorporates a condensate collector kit that can be coupled to a drain line with a siphon trap. The flue is inspected from the point at which the duct connects with the boiler.
3 Ducting system WItH INlEt BENDThis is the quickest ducting solution for lining an existing but unsuitable chimney. The connection between the boiler and the inlet end of ducting system is made with a 90° bend. Using this configuration, the Ø 80 condense tank kit will be positioned near the boiler flue outlet (code 3.012009).
Description Code
Cover kit for EOLO Star 24 3.019090
Cover kit for EOLO Extra 24 kW 3.016304
Cover kit for EOLO Extra 28/32 kW 3.016022
Cover kit for MINI EOLO 28 - MAIOR EOLO 3.020805
Cover kit for MINI EOLO 24/X 24 3.020897
Cover kit for CAESAR 14 3.014201
Cover kit for Super CAESAR 17 3.015980
COVER KItS
4948
Description Code
Complete terminal kit 3.011582
4 extension pipes Ø 80 1 m long 3.011583
1 extension pipe Ø 80 2 m long 3.011584
5 pipe clamps kit 3.011585
3 spacer pipe clamps kit 3.011586
Adjustable support chimney plate and chimney hanging bracket 3.011600
Kit comprised of “T” fitting, aluminum draining cap (with its exit), chimney closing panel for inspection, chimney inspection door and grommet Ø 16
3.011601
“T” coupling seal kit with condensate trap 3.011961
Description Code
Condensate siphon kit 3.011599
Support bend kit 3.012007
“T” connector kit 3.011595
Chimney hole closing panel 3.012008
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
FluE SyStEm COmPONENtS Ø 80 mm
“Blu
E S
ER
IES
” Fl
uE
Sy
St
Em
S
5150
VICT
RIX
50/7
5/90
/115
VICT
RIX
Zeus
Sup
erio
r kW
VICT
RIX
Zeus
VICT
RIX
Supe
rior k
W
VICT
RIX
Supe
rior k
W X
VICT
RIX
VICT
RIX
X / V
ICTR
IX R
EOLO
Ext
ra k
W H
P
HERC
ULES
Con
dens
ing
HERC
ULES
Sol
ar
ZEUS
Sup
erio
r kW
AVIO
/ZEU
S kW
MAI
OR E
OLO
NIKE
Min
i 28
kW S
peci
al
MIN
I NIK
E/EO
LO
MIN
I NIK
E/EO
LO X
NIKE
/EOL
O St
ar
EOLO
Ext
ra k
W
JULI
US
CAES
AR 1
4
Supe
r CAE
SAR
17
Description Code
Safety kit for single boiler(it includes thermometer, thermometer holder, lock, thermostatwith manual reset, connection tap for pressure gauge,manual reset pressostat, gas intercepting valve trap,expansion vessel connection)
3.015222 •
Three-way valve kit connection to the separate storage tank(it includes the storage tank probe) 3.015223 •
Hydraulic manifold kit for single boilerto allow rise in head/flow rate of the system(it includes a mud-filter on the return pipe)
3.015224 •
Hydraulic manifold kit for 2 boilers in cascade(including the intercepting valve and the non-returnfor each appliance)
3.015225 •
Hydraulic manifold kit for additional boiler in cascade(including the intercepting valve and the non-return valve) 3.015226 •
Safety kit for boilers in cascade(it includes thermometer, thermometer holder, lock thermostatwith manual reset, connection tap for pressure gauge,manual reset pressostat, gas intercepting valve trop,expansion vessel connection)
3.015227 •
Condensate neutralizer kit for cascade installation 3.019464 •
Condensate neutralizer kit for single installation 3.019857 •
Granulate for condensate neutralizer 3.019865 •
OP
tIO
NS
RA
NG
E
OP
tIO
NS
RA
NG
E
Hydraulic system
5352
VICT
RIX
50/7
5/90
/115
VICT
RIX
Zeus
Sup
erio
r kW
VICT
RIX
Zeus
VICT
RIX
Supe
rior k
W
VICT
RIX
Supe
rior k
W X
VICT
RIX
VICT
RIX
X / V
ICTR
IX R
EOLO
Ext
ra k
W H
P
HERC
ULES
Con
dens
ing
HERC
ULES
Sol
ar
ZEUS
Sup
erio
r kW
AVIO
/ZEU
S kW
MAI
OR E
OLO
NIKE
Min
i 28
kW S
peci
al
MIN
I NIK
E/EO
LO
MIN
I NIK
E/EO
LO X
NIKE
/EOL
O St
ar
EOLO
Ext
ra k
W
JULI
US
CAES
AR 1
4
Supe
r CAE
SAR
17
Description Code
Hydraulic separator for 100 kW installations 3.020839 •
Hydraulic separator for 200 kW installations 3.021337 •
Hydraulic separator for 400 kW installations 3.021378 •
Hydraulic alignment kit for VICTRIX 50/75 and VICTRIX 90/115 in cascade 3.021385 •
Flue alignment kit for VICTRIX 50/75 and VICTRIX 90/115 in cascade 3.021386 •
Low temperature second zone kit 3.018836 •
High temperature second zone kit 3.018837 •
2 high temperature zones kit 3.018838 •
Additional low temperature zone kit for ABT version 3.018839 •
2 low temperature zones kit 3.020003 •
OP
tIO
NS
RA
NG
E
OP
tIO
NS
RA
NG
E
Hydraulic system
5554
VICT
RIX
50/7
5/90
/115
VICT
RIX
Zeus
Sup
erio
r kW
VICT
RIX
Zeus
VICT
RIX
Supe
rior k
W
VICT
RIX
Supe
rior k
W X
VICT
RIX
VICT
RIX
X / V
ICTR
IX R
EOLO
Ext
ra k
W H
P
HERC
ULES
Con
dens
ing
HERC
ULES
Sol
ar
ZEUS
Sup
erio
r kW
AVIO
/ZEU
S kW
MAI
OR E
OLO
NIKE
Min
i 28
kW S
peci
al
MIN
I NIK
E/EO
LO
MIN
I NIK
E/EO
LO X
NIKE
/EOL
O St
ar
EOLO
Ext
ra k
W
JULI
US
CAES
AR 1
4
Supe
r CAE
SAR
17
Description Code
Additional expansion vessel
3.018433 • • • ZEUS only
3.017514 •X 24, X 12only
Shut off knobs 3.5324 • • • • • • • • • • • • • • •
Shut off knobs with filters 3.015854 • • • • • • • • • • •
Solar valve 3.018911 • • • • • •
Mixing valve 3.019099 • • • • • • •
OP
tIO
NS
RA
NG
E
OP
tIO
NS
RA
NG
E
Hydraulic system
5756
VICT
RIX
50/7
5/90
/115
VICT
RIX
Zeus
Sup
erio
r kW
VICT
RIX
Zeus
VICT
RIX
Supe
rior k
W
VICT
RIX
Supe
rior k
W X
VICT
RIX
VICT
RIX
X / V
ICTR
IX R
EOLO
Ext
ra k
W H
P
HERC
ULES
Con
dens
ing
HERC
ULES
Sol
ar
ZEUS
Sup
erio
r kW
AVIO
/ZEU
S kW
MAI
OR E
OLO
NIKE
Min
i 28
kW S
peci
al
MIN
I NIK
E/EO
LO
MIN
I NIK
E/EO
LO X
NIKE
/EOL
O St
ar
EOLO
Ext
ra k
W
UB In
ox 8
0-2
UB In
ox 1
20-2
UB In
ox 2
00-2
UB In
ox S
olar
200
-2
Description Code
Recirculation kit (with domestic hot water pump)
3.015380 • • • •
3.020001 •
Recirculation kit (only probe pipe)
3.012944 • •3.011547 •3.013498 •3.022198 •3.022199 • •3.022200 •
Anti-scale kit
3.016305 • • •3.014945 •3.013860 •3.017323 •
D.H.W. expansion vessel
3.017744 •
3.020400 •
OP
tIO
NS
RA
NG
E
OP
tIO
NS
RA
NG
E
Hydraulic system
5958
VICT
RIX
50/7
5/90
/115
VICT
RIX
Zeus
Sup
erio
r kW
VICT
RIX
Zeus
VICT
RIX
Supe
rior k
W
VICT
RIX
Supe
rior k
W X
VICT
RIX
VICT
RIX
X / V
ICTR
IX R
EOLO
Ext
ra k
W H
P
HERC
ULES
Con
dens
ing
HERC
ULES
Sol
ar
ZEUS
Sup
erio
r kW
AVIO
/ZEU
S kW
MAI
OR E
OLO
NIKE
Min
i 28
kW S
peci
al
MIN
I NIK
E/EO
LO
MIN
I NIK
E/EO
LO X
NIKE
/EOL
O St
ar
EOLO
Ext
ra k
W
UB In
ox 8
0-2
UB In
ox 1
20-2
UB In
ox 2
00-2
UB In
ox S
olar
200
-2
Description Code
Cascade and zone regulator kit 3.015244 •
Wall box kit for cascade and zone regulator 3.015265 •
Remote control for single light commercial boilers 3.020358 •
Zone manager kit 3.015264 •
Modulating room thermostat 3.015245 •
Flow probe kit 3.015267 •Storage tank sensor kit (to manage the storage tank as a zone) 3.015268 •
Super CAR (modulating remote control) 3.016577 • • • • • • • • •
CARV2 (modulating remote control) 3.021395 • • • • • • • • • • • • • • •
CAR Universal (modulating remote control) 3.020946 • • • • • • • • • • • • • • •
Mini CRD (Mini Digital Remote Control) 3.020167 • • • •
OP
tIO
NS
RA
NG
E
OP
tIO
NS
RA
NG
E
Climatic regulation
6160
VICT
RIX
50/7
5/90
/115
VICT
RIX
Zeus
Sup
erio
r kW
VICT
RIX
Zeus
VICT
RIX
Supe
rior k
W
VICT
RIX
Supe
rior k
W X
VICT
RIX
VICT
RIX
X / V
ICTR
IX R
EOLO
Ext
ra k
W H
P
HERC
ULES
Con
dens
ing
HERC
ULES
Sol
ar
ZEUS
Sup
erio
r kW
AVIO
/ZEU
S kW
MAI
OR E
OLO
NIKE
Min
i 28
kW S
peci
al
MIN
I NIK
E/EO
LO
MIN
I NIK
E/EO
LO X
NIKE
/EOL
O St
ar
EOLO
Ext
ra k
W
UB In
ox 8
0-2
UB In
ox 1
20-2
UB In
ox 2
00-2
UB In
ox S
olar
200
-2
Description Code
External probe
3.014083 • • • • • • • • • • • • • • •3.015266 •
Telephonic remote control 3.013305 • • • • • • • • • • • • • • • •
GSM telephonic remote control 3.017182 • • • • • • • • • • • • • • • •
CRONO 7 3.021622 • • • • • • • • • • • • • • • • • • • • •Radio-timer/room thermostat (wireless) 3.014439 • • • • • • • • • • • • • • • • • • • • •Room thermostat 3.012287 • • • • • • • • • • • • • • • • • • • • •
Control box for pumps and zone 3.011668 • • • • • • • • • • •
Relay board kit
3.015350 • • • • • • • • •3.017331 •
Anti-freeze protection kit -15 °C
3.016144 •3.015361 •3.015348 • •3.017324 • • • • •3.021474 • EOLOonly EOLOonly
Safety thermostat kit
3.019869 •3.019229 • •
Solar probe kit 3.021452 • •
OP
tIO
NS
RA
NG
E
OP
tIO
NS
RA
NG
E
Climatic regulation
6362
Description Code
All-purpose connection kit 3.011667
Connection kit for NIKE/EOLO Star 24and MINI NIKE/EOLO 24 3.015229
Connection kit for NIKE Mini 28 kW Special 3.016671
Connection kit for MAIOR EOLO and MINI EOLO 28 3.021453
Connection kit for EOLO Extra 24 kW 3.019335
Connection kit for EOLO Extra 28/32 kW and EOLO Extra kW HP 3.019329
Connection kit for VICTRIX 26 3.017494
Connection kit for VICTRIX X 12/24 3.017495
Connection kit for VICTRIX Zeus 26 3.020505
Storage tank connection kit for VICTRIX Superior 32 kW X 3.019213
Storage tank connection kit for MINI X and MAIOR X 3.020934
Storage tank connection kit for VICTRIX X 12/X 24 3.022193
Solar panel kit for HERCULES Condensing(pipes and fittings) 3.019998
Solar panel kit for 200 litre storage tank unit(pipes and fittings) 3.022195
Solar panel kit for 200 litre storage tank units connected in parallel (pipes and fittings) 3.022196
Solar panel kit for 120 litre storage tank unit(pipes and fittings) 3.022197
Connection kit for 200 litre storage tank unitsconnected in parallel (sanitary side and system side) 3.022212
Code Description EAN code
3.5324 Shut off knobs 8015065700897
3.010347 Recirculation kit (only probe pipe) 8015065706561
3.010351 Twin pipes complete kit Ø 80/80 8015065707339
3.010352 Concentric vertical complete kit Ø 80/125 8015065707322
3.010526 Concentric horizontal complete kit Ø 80/125 8015065707315
3.010739 1 extension pipe Ø 60/100 2 m long 8015065707377
3.010741 4 extension pipes Ø 80 1 m long 8015065707155
3.010945 1 extension pipe Ø 80/125 1 m long 8015065707476
3.010946 1 extension pipe Ø 80/125 2 m long 8015065707483
3.010947 1 insulated extension pipe Ø 80 1 m