Page 1: EXAMPLE WALL SECTION RESIDENTIAL BUILDING CODE A6 · 13/02/2015  · 151 roof felt, r9o5.2.7 1" clr air chute, btw ea truss, r8o6.3 ice & water shield, extend 24" inside ext wall,

151 ROOF FELT, R9O5.2.7

1" CLR AIR CHUTE, BTW EA TRUSS, R8O6.3

ICE & WATER SHIELD, EXTEND 24" INSIDE EXT WALL, R905.2.7.1

DRIP EDGE·---­

FACIA BOAR

HURRICANE CLIPS, PER TRUSS MANUFACTURER, R8O2.11.

RIM BOARD-------

2X6 SILL PLATE, w/ 1 /2"X1 O" ANCHOR BOLT w 7" MIN EMBED, 72" O.C., R403.1.6

PROTECT INSUL TO BELOW GRADE

,"-.";,"'--.'/"";,"�/ 4" PERFORATED DRAINS SET IN GRAVEL W/ SOIL SEG FABRIC WRAP.

PRE-ENGINEERED TR w/6" MIN. ENERGY HEEL, 42 PSF LL

YPSUM BOARD, TYP.

2"X6" WOOD STUDS, 12 BTR, 0 16" O.C.

R-21 MIN. INSULATION

SHEATHING, CONT TO BOTTOM CORD OF TRUSS

AIR BARRIER

SIDING, R7O3

1-::c C)

j:;j ::c C) z ::::i j:;j 0

I 0,

IM JOIST INSULATION, R-21, MIN. W/

z 0

z => 0 • .... 0,

I 'io i-,.. I

i-,..

VAPOR RETARDER &THERMAL BARRIER.

YPSUM BD CEILING, TYP., PER R501.3.

YPSUM BD WALLS w/ THERMAL BARRIER, TYP., PER R404. 1 .2.3.6. 1 •

NOTE: INSTALL ROOF VENTS, PER R806, SEE ROOF PLAN.

VAPOR RETARDER

NOTE: RADON MITIGATION SYSTEM TIED INTO FLOOR DRAINS AND SUMP. SEE FLOOR PLAN FOR ADD'L RADON MITIGATION INFORMATION.

4" CIP CONCRETE SLAB over 6MIL POLY VB, SEALED, over 4" GRAVEL

O"XB" FOOTING CONT. SET over UNDISTURBED EARTH

Date:

Job No.:

Drawn By:

Revised:

Approved By:

Sheet:

2/13/2015

HANDOUTS

RDA

3/5/2015

DWN

A6

EXAMPLE WALL SECTIONRESIDENTIAL BUILDING CODE

SCALE: 3/8"=1'-0"I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Handout - Residential Wall Section Sample 242.pdf Page 1 of 1