FACA
DE
60TH
ERM
AL
FLU
SH G
LAZI
NG
CU
RTA
IN W
ALL
SYS
TEM
PRODUCT MANUALREV. 1.1Aug. 2016
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
ii
Index ........................................................................................................................................................................................................................ ii
Legal Disclaimer ................................................................................................................................................................................................... 1
Overview ................................................................................................................................................................................................................ 2
Profile & Hardware Identification................................................................................................................................................................... 3
Curtain Wall System Profiles .............................................................................................................................................................................................................3-5
Hardware Components ..................................................................................................................................................................... 5-6
CF60 Machining ......................................................................................................................................................................................................
Mullion & Transome Faceplate Machining ................................................................................................................................................................................7
H/D Transome Machining ....................................................................................................................................................................................................................... 8
Sill Machining ...................................................................................................................................................................................................................................................9
CF60 Assembly ........................................................................................................................................................................................................
Mullion Spigot Assembly .................................................................................................................................................................................................................10-12
Toggles & Spacers ........................................................................................................................................................................................................................................13
Flush Glaze Channel ...................................................................................................................................................................................................................................14
Flush Glazing Frame Assembly ..........................................................................................................................................................................................................15
Glass Supports ................................................................................................................................................................................................................................................16
Cutting Formulas ................................................................................................................................................................................................................................... 17-22
Sealant Procedures ....................................................................................................................................................................................................................................23
Recommended Sealants ....................................................................................................................................................................................................................... 24
Flush Glazing Frame Assembly ................................................................................................................................................................................................ 25-26
Sealant Calculator .......................................................................................................................................................................................................................................27
Setting Blocks................................................................................................................................................................................................................................................ 28
Fitting of Toggles .................................................................................................................................................................................................................................29-30
Fitting of Spacers ..........................................................................................................................................................................................................................................31
Fitting of Expansion Profiles ........................................................................................................................................................................................................32-33
Fitting of Brackets & base Plates ............................................................................................................................................................................................ 34-38
CF60 Specifications ...........................................................................................................................................................................................40
Gasket & Glazing Options .....................................................................................................................................................................................................................40
CF60 Fabrication ................................................................................................................................................................................................41
Fabrication Instructions .................................................................................................................................................................................................................. 41-44
CF60 Typical Sections .......................................................................................................................................................................................45
Horizontal - Double & Single Glazing ...................................................................................................................................................................................45-46
Vertical - Double & Single Glazing ...........................................................................................................................................................................................47-48
Sill Detail ................................................................................................................................................................................................................................................... 49-50
Base Plate Detail ...........................................................................................................................................................................................................................................51
Bracket Detail ................................................................................................................................................................................................................................................ 52
Other Standard Details ....................................................................................................................................................................................................................53-57
INDEX
THER
MA
L FL
USH
GLA
ZIN
G
CURT
AIN
WA
LL S
YSTE
M
FAC
AD
E 60
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
1
By continuing to use this documentation you acknowledge that you understand and accept the legal disclaimer.
LEGAL DISCLAIMER
General Documentation DisclaimerThis manual is intended as a manufacturing and installation advisory document. For correct specifications, sizing of profiles and structural information please consult the Starfront Application. If the information you require is not available through the Starfront Application, please contact your stockist before proceeding. It is advisable to have all sizing and performance criteria checked by a qualified structural engineer to ensure that the required criteria will be met.
All information, recommendations or advice contained in this documentation is given in good faith to the best of Wispeco’s knowledge and is based on current procedures in effect.
Since the actual use of this documentation by the user is beyond the control of Wispeco, such use is within the exclusive responsibility of the user. Wispeco cannot be held responsible for any loss incurred through incorrect or faulty use of this documentation. Training of Wispeco systems is important for ensuring correct procuderes in the manufacturing of products.
Great care has been taken to ensure that the information provided is correct.
Ensure that you have the latest available manual. The revision number and date can be checked on the latest Starfront version.
Wispeco will accept no responsibility for any errors and/or omissions, which may have inadvertently occurred.
This Guide may be reproduced in whole or in part in any form or by any means provided the reproduction or transmission acknowledges the origin, revision number and copyright date.
Specifications concerning products and applicationsThis manual is based on standard configurations only. As there are many configurations not covered in this manual, contact your stockist with regards to a configuration not represented herein if required.
AutoDesk drawings (CAD Symbol Library) are available on request and can be issued with the consent of the Wispeco Technical Department.
All mechanical joints must be sealed with a Crealco approved joint sealer. Failure to correctly seal the joints can affect the performance of the system. Information on joint sealing can be found in the Cleaning & Mainanace Manual available for download from the Wispeco website or from Starfront.
All drawings in the Wispeco Documentation are shown NOT to scale and are used for illustative purposes only.
Wispeco will not accept responsibility for the use of standard products since Wispeco does not know where these products are being installed.
The hardware recommended in this documentation is suitable for use in most atmospheric environments. When hardware is used in severe coastal environments the manufacturer of the hardware must be consulted.
The use of non-specified hardware or incorrect mechanisal fasteners can adversly affect the mechanical and weathering performance of the system and we strongly advise against deviations. A Wispeco Consultant can advise you of any hardware issues and limitations with regard to this system.
The use of anti-magnetic stainless steel screws and aluminium pop rivets is recommended to reduce galvanic corrosion in harsh environments.
Fixing lugs on frames must be positioned as per the user manual and used in accordance to the AAAMSA specifications. When profiles are screwed together the screw centers must also be according to the user manual or as specified by an engineer.
All glass used within Wispeco products must comply with SAGGA regulations. Laminated glass must not stand in water.
THER
MA
L FL
USH
GLA
ZIN
G
CURT
AIN
WA
LL S
YSTE
M
FAC
AD
E 60
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
2
Special attention needs to be noted regarding the drainage/decompression, as water must be drained smoothly under control, one must ensure that all profiles are cleanly cut & de-burred. Another important note is to ensure that all the screws are firmly fixed & that no burr is collected when tightning of screws under the washers. It is recommended to always use structural silicone where required.
Regarding the cutting of gaskets, it is recommended to cut slightly longer to allow for shrinkage (avoid any stretching when fitting the gaskets). Should gaskets be difficult to insert into the profiles, silicone spray can be applied. Approved vulcanising glue to be applied on end joints as shown in the manual.
Another important consideration to note is that the glass may not come into contact with the aluminium without gaskets & glass setting blocks. It is recommended that for each project, a structural engineer confirms windload as well as all fixings, brackets & bracket positioning.
Before making a sample to have tested for AAAMSA certification purposes, please contact the testing station to confirm what size the frame the curtain wall will be tested in needs to be in order to be properly clamped in the test rig.
NB!!Due to the fact that flush glazing curtain wall systems require scaffolding for installation, Wispeco recommends a max. height of 10 m (3 storey buildings), should higher screens be required, an engineer should be consulted.
OVERVIEW
GENERAL SYSTEM
In order for this product to function properly, it is important to follow the correct procedures of this manual as well as attend the training session at an approved Wispeco training facility.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
3
100MM EXPANSION BRACKET(STILL TO BE CUT)
BASE PLATE(STILL TO BE CUT)
GLAZING ADAPTOR(STILL TO BE CUT)
DOUBLE GLAZING GLASS SUPPORT SINGLE GLAZING GLASS SUPPORT
W3297460 mm MULLION BRACKET
SILL
PROFILE IDENTIFICATION
DIE No. W57171 F60 Mullion 100mm
DIE No. W34912 F60 Mull/Trnsm Face Plate
DIE No. W34911 F60 Transome Cover Clip-on
DIE No. W34910 F60 Transome 50 mm
FLUSH GLAZING CURTAIN WALL SYSTEM PROFILES
DIE No. W35070 F60 Sill
DIE No. W35233 F60 Transome 100 mmDIE No. W57638 F60 Transome 100 mm H/D
NON STOCK ITEM
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
4
W35122100 mm EXPANSION PROFILE
W35178160 mm EXPANSION PROFILE
W35122100 mm EXPANSION PROFILE
W35178160 mm EXPANSION PROFILE
PROFILE IDENTIFICATION
DIE No. W35122F60 Expansion Profile 100 mm
DIE No. W35178F60 Expansion Profile 160 mm
W35122100 mm EXPANSION PROFILE
W35178160 mm EXPANSION PROFILE
DIE No. W57302 F60 Mullion 160 mm
DIE No. W57411 F60 Mullion 190 mm
DIE No. W35361F60 Expansion Profile 190 mm
DIE No. W35835 F60 Flush Glazing S/Glaze Glass Support
DIE No. W35705 F60 Flush Glazing D/Glaze Glass Support
DIE No. W57643 F60 Flush Glaze Frame
FLUSH GLAZING CURTAIN WALL SYSTEM PROFILES
DIE No. W35885 F60 Flush Glaze Single Double Glazing Adaptor
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
5
100 mm EXPANSION BRACKET
BASE PLATE(STILL TO BE CUT)
DOUBLE GLAZING GLASS SUPPORT SINGLE GLAZING GLASS SUPPORT
W3297460 mm MULLION BRACKET
DIE No. W35177 F60 Base Plate
PROFILE IDENTIFICATION
DIE No. W32974 60 mm Mullion Bracket
100 mm EXPANSION BRACKET
BASE PLATE(STILL TO BE CUT)
DOUBLE GLAZING GLASS SUPPORT SINGLE GLAZING GLASS SUPPORT
W3297460 mm MULLION BRACKET
THCW BASE PLATEW35177
DOUBLE GLAZING GLASS SUPPORT SINGLE GLAZING GLASS SUPPORT
W3297460 mm MULLION BRACKET
DIE No. W32992 Lock Washer
Hardware code: F60-GSS-57172Packs of 20
F60 Spigot Transome
FLUSH GLAZING CURTAIN WALL SYSTEM PROFILES
F60 Flush Glaze Toggle
F60 Flush Glaze Spacer
Hardware code: F60-FGT-35701Packs of 50
Hardware code: F60-FGS-35702Packs of 50
ALUMINIUM HARDWARE PACKS
THCW BASE PLATEW35177
DOUBLE GLAZING GLASS SUPPORT SINGLE GLAZING GLASS SUPPORT
W3297460 mm MULLION BRACKET
DIE No. W52695 Corner Cleat
Hardware code: LGC-52695-42Packs of 50
DIE No. 35111 50 X 25 Rectangular Tube
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 08:42:37 AM, DWG To PDF.pc3
DIE No. W36015 F60 Flush Glaze Top Trim DIE No. W36014 F60 Flush Glaze Bottom Trim
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 08:42:37 AM, DWG To PDF.pc3
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
6
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
179.
5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER F60-FPS F60 Face Plate Spacer (PVC)
F60-S14MM F60 14 mm Spacer
F60-W10X3 Pressure Plate Washer
F60-PPS6.3X24 6.3 x 24 Pressure Plate Screw
GSB25244/5 Glass Setting Blocks
GSBLOCKS Glass Setting Blocks
THERMAL COMPONENTS
GLAZING ACCESSORIES
FASTENERS
GASKETS
FLUSH GLAZING HARDWARE COMPONENTS
HARDWARE COMPONENTS
F60-TSS5.5X705.5 x 70 St. St. Self Drilling Screw
(No. 8 drill bit)
F60-TSS6.3X206.3 x 20 St. St. Self Drilling Screw
(No. 10 drill bit)
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
23
36
23
36
F60-TACOE Transome End Caps
F60-EPS75MM or F60-EPS130MM
Expansion Profile Spacer
F60-VG Vulcanising Glue
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
23
36 FSP-089P-SS No. 8 x 9 Panhead St. Steel screw
F60-T20X20 Sondor Tape
GSL-AL-H602 Y Seal Gasket
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
319.
5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
F60-PIG Push-In Gasket
60
5.9
20
25
10
GLAZING ADAPTOR(STILL TO BE CUT)
17
9.5
70
24
36
31
9.5
28 mm DOUBLE GLAZING SPACER
14 mm SINGLE GLAZING SPACER
GBF-EPVC Butterfly EuroGasket
GSL-WSF Weatherseal Gasket23
36
F60-SEC Sill End Caps
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
7
Section not to scale
RECTANGULAR TUBE-SUB FRAME
FACADE 60 MACHINING
DIE No. 35111 50 X 25 Rectangular Tube
OV
ER
ALL
HE
IGH
T O
F O
PE
NIN
G
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 08:10:32 AM, DWG To PDF.pc3
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
8
TOP AND BOTTOM TRIMS
FACADE 60 MACHINING
Ø6
6
Ove
rall
Wid
th m
inis
50
(Exc
ludi
ng th
e ga
p be
twee
n th
e w
all a
nd th
e R
ect.
Tube
) Ø65090
0 ce
ntre
s
5090
0 ce
ntre
s
6
Ove
rall
Wid
th m
inis
50
(Exc
ludi
ng th
e ga
p be
twee
n th
e w
all a
nd th
e R
ect.
Tube
)
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 08:31:55 AM, DWG To PDF.pc3
Section not to scale
DIE No. 36015 F60 Flush Glaze Top Trim DIE No. 36014 F60 Flush Glaze Bottom Trim
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
9
60 60
16.5
20
6
17
Ø6
250
2025
0
60
Ove
rall
Mul
lion
Hei
ght
60
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/27 11:25:42 AM, DWG To PDF.pc3
Section not to scale
DIE No. 34912 F60 Mull/Trnsm Face Plate
MULLION FACE PLATE MACHINING
NOTE: Should different hole centres be required, please contact your stockist as well as confirming with engineer for correct holes centres.
Pre punched dia. 6mm holes.
NOTE: Important to always fit the mullion/transome face plate spacer (black pvc spacer) between the mullion or transome & the mullion/transome face plate. Failure to fit the pvc spacer will cause the curtain wall to leak.
Machining to accommodate the sondor tape(Prevents air infiltration)
FACADE 60 MACHINING
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
10
20
6
17
Ø6
250
2025
0
TRA
NS
OM
E W
IDTH
= M
ULL
ION
CE
NTR
E T
O C
EN
TRE
MIN
US
65
Section not to scale
FACADE 60 MACHININGTRANSOME FACEPLATE MACHINING
NOTE: Should different holes centres be required, please contact your stockist as well as confirming with engineer for correct holes centres.
DIE No. 34912 F60 Mullion/Transome Face Plate
Pre punched dia. 6mm holes
NOTE: The 2 holes on each end of the transome are to be left open inorder to fix the transome to the spigot. (Using a No 6.3 x 20 Tek screw)
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
11
FACADE 60 MACHININGH/D TRANSOME MACHINING
DIE No. 57638F60 Transome 100 mm H/D
45.6
45.6
50
Tran
som
e W
idth
= C
entre
to C
entre
min
us 6
5
Section not to scale
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
12
FACADE 60 MACHINING
Section not to scale
DIE No. 35070 F60 Sill
SILL MACHINING
12
88 (for 100 mm Mullion)
148 (for 160 mm Mullion)
178 (for 190 mm Mullion)
NOTE: Use structural silicone when sealing the sill into position, as well as sealing on the sides against the 50 x 25 tubing.
4010
0
OV
ER
ALL
WID
TH m
inus
50
(Exc
ludi
ng g
ap b
etw
een
wal
l & R
ect.
Tubi
ng)
8
8
4010
0±1
200
CE
NTR
ES
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/28 10:53:03 AM, DWG To PDF.pc3NOTE: Ensure that no drainage holes are positioned under the mullions.
NOTE: Use the end caps only when 2 sills are been joined together.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
13
30
30
30
40
2020
45
70
The spigots can be adjusted up or down by loosening the bottom tek screw (2mm)
FACADE 60 ASSEMBLYTRANSOME SPIGOT ASSEMBLY
30
OV
ER
ALL
MU
LLIO
N H
EIG
HT
30
2020
2020
30
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
14
FACADE 60 ASSEMBLYTRANSOME SPIGOT ASSEMBLY
30
30 30
30
40
40
100 mm Transome Spigot assembly for the 100 mm Mullion
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
15
FACADE 60 ASSEMBLYTRANSOME SPIGOT ASSEMBLY
100 mm Transome Spigot assembly for the 160 mm & 190 mm Mullion
30
30
40
40
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
16
Ø6 2020
100
Ø6 2020
100
6
FACADE 60 MACHININGTOGGLE & SPACER ASSEMBLY
DIE No. W35701 F60 Flush Glaze ToggleDIE No. W35702 F60 Flush Glaze Spacer
These profiles are aluminium hardware items and sold in packs of 50 with the holes pre-punched. (See Hardware identification page for codes)
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
17
Ove
rall
Leng
th =
Cen
tre to
Cen
tre m
inus
21
Ove
rall
Leng
th =
Cen
tre to
Cen
tre m
inus
21
14
FACADE 60 MACHINING FLUSH GLAZING FRAME ASSEMBLYDIE No. 57643 F60 Flush Glazing Frame
6.5 2.5
NB:Besides cutting the glass supports together with the frame, pre-drill the holes as shown to take the No. 8 x 9 panhead screws, this is to prevent drilling into the glass when the glass panels have been siliconed into position.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
18
NB:For accurate cutting of the flush glaze glass supports, fit the glass supports together with the flush glaze framing when cutting.(Remember to pre-drill the holes through the glass supports & frame).
DIE No. W35835F60 Flush GlazingS/Glaze Glass Support
DIE No. W35705F60 Flush GlazingD/Glaze Glass Support
FACADE 60 MACHININGGLASS SUPPORTS ASSEMBLY
5
5
5
5
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
19
FACADE 60 MACHINING
OPTION 133 mm spaces between glass panels
A
A - 65 mm
100 mm (3 per panel)
60
A - 85 mm
2.5 A - 65 mm
A - 65 mm
100 mm (3 per panel)
A - 21 mm
A - 33 mm
A - 17
HORIZONTAL CUTTING FORMULA-SINGLE GLAZING
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
20
FACADE 60 MACHINING
OPTION 226 mm spaces between glass panels
A
A - 65 mm
100 mm (3 per panel)
60
A - 85 mm
2.5 A - 65 mm
A - 65 mm
100 mm (3 per panel)
A - 21 mm
A - 26 mm
A - 17
HORIZONTAL CUTTING FORMULA-SINGLE GLAZING
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
21
FACADE 60 MACHININGHORIZONTAL CUTTING FORMULA-DOUBLE GLAZING
OPTION 133 mm spaces between glass panels
A
A - 65 mm
100 mm (3 per panel)
A - 33 mm
60
A - 85 mm
2.5 A - 65 mm
A - 65 mm
100 mm (3 per panel)
A - 21 mm
A - 17
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
22
FACADE 60 MACHININGHORIZONTAL CUTTING FORMULA-DOUBLE GLAZING
OPTION 226 mm spaces between glass panels
A
A - 65 mm
100 mm (3 per panel)
A - 26 mm
60
A - 85 mm
2.5 A - 65 mm
A - 65 mm
100 mm (3 per panel)
A - 21 mm
A - 17
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
23
5.5 2.56.5 2.5
Align glass with pip as shown. Ensure structural sealant is applied up to this point.
1. Before starting any flush glazing project, an adhesion test must be carried out with a certified or reputable sealant testing laboratory. The purpose of the adhesion test is to ensure that each substrate used in the project (aluminium profiles, glass, gaskets etc) will be compatible. Upon completion of testing, a written product recommendation will be issued.(procedure can take up 6 weeks).
2. All surfaces (glass, aluminium & gaskets) must be clean, dry & dust free with no damage due to outdoor weathering. Use the correct cleaning solvents & procedures as recommended by the silicone supplier.
3. All the flush glazing glass panel edges must be polished all round. Ensure the glass panels which have special coatings are correctly placed within the frame. Be careful when handling the glass as finger prints can cause adhesion loss.
4. Once the glass is securely positioned within the frame, a continuous application of sealant is to be applied, avoiding any air entrapments. Whether a one or two part component sealant is used, the sealant must be exposed to atmospheric moisture to cure. Always ensure the sealant is within its shelf life.
5. Once the glazed panels has been structurally siliconed, the panels may not be moved until the correct curing time has been adhered to as specified.(preferable to use a 2 part silicone).
6. Always ensure correct adhesion testing is done once curing has been completed.
7. When placing orders onto your stockist for any flush glazing project, please stipulate that the profiles which are to be powdercoated is for a flush glazing project, so that the powdercoating batch number is recorded.
8. The maximum length for a flush glazing panel may not exceed 2000 mm.
Ensure no air bubbles when appling sealant.
FACADE 60 ASSEMBLYSEALANT PROCEDURES
This manual is intended as a basic guideline only on the proper procedures for structural siliconing & Wispeco will not be held respon-sible for any loss or damage whatsoever. An engineer or competent person is required for all projects over 10 m high.
Important information regarding structural siliconing:
OPTION 226 mm spaces between glass panels
OPTION 133 mm spaces between glass panels
Align glass as shown. Ensure structural sealant is applied up to this point.
6.5 2.5
NB:To allow for ease of fitting the glass support profiles around the frame once the glass panel has been siliconed into place, fit masking tape over the area as shown before commencing with siliconing as to prevent any silicone onto this area.(Ensure that no tape is fitted over the area where the silicone will be applied).
To prevent any silicone from been pushed through between the glass & the gasket, apply weight onto the glasspanel while applying the silicone.
To prevent any silicone from been pushed through between the glass & the gasket, apply weight onto the glasspanel while applying the silicone.
Ensure no air bubbles when appling sealant.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
24
FACADE 60 ASSEMBLYRECOMMENDED SEALANTS
N.B.FG Trading or Dow Corning can assist with the requirements for structural silicone (including the adhesion test) & polycord.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
25
5.5
6 62
24.7
6
6.38
5
5
5.5
18
18
1
Step 1:Once the frame has been assembled together, the weatherseal gasket can be inserted into the profile as shown on all 4 sides.
Step 2:After taking the required steps to ensure the glass & aluminium profiles have been adequately prepared & cleaned, the glass can now be placed on top of the weatherseal gasket as shown & structural silicone applied. (See important notes on page about sealant procedures).
Step 3:Once the structural silicone has been applied, the glass supports can be fitted on all 4 sides & fixed every 800 mm centres with No. 8 x 9 panhead S/S screws.
Step 4:After fitting the glass supports on all 4 sides, crealco silicone sealer is then applied to close off the cavity as shown. For double glazing units, 8 mm polycord is fitted into the cavity & then silicone sealer applied. Remember to fit the appropiate glass setting blocks on the bottom glass supports.
UNIQUE FEATUREThe add-on glass support has been developed to assist with the structural silicone glazing of panels by making it easier to inject and control the silicone without any obstructions.
The glass support is affixed after the curing of the structural silicone and allows for simple completion of the weather seal silicone process.
FACADE 60 ASSEMBLYFLUSH GLAZING FRAME ASSEMBLY
Step 1 Step 2 Step 3 Step 4
OPTION 133 mm spaces between glass panels
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
26
2.5
2.5
6 6
2
2
24.7
60.97
6.38
2
18
18
Step 1:Once the frame has been assembled together, the weatherseal gasket can be inserted into the profile as shown on all 4 sides.
Step 2:After taking the required steps to ensure the glass & aluminium profiles have been adequately prepared & cleaned, the glass can now be placed on top of the weatherseal gasket as shown & structural silicone applied. (See important notes on page of sealant procedures).
Step 3:Once the structural silicone has been applied, the glass supports can be fitted on all 4 sides & fixed every 800 mm centres with No. 8 x 9 panhead S/S screws.
Step 4:After fitting the glass supports on all 4 sides, crealco silicone sealer is then applied to close off the cavity as shown between the glass & the glass support profile. Remember to fit the appropiate glass setting blocks on the bottom glass supports.
OPTION 226 mm spaces between glass panels
Step 1 Step 2 Step 3 Step 4
UNIQUE FEATUREThe add-on glass support has been developed to assist with the structural silicone glazing of panels by making it easier to inject and control the silicone without any obstructions.
The glass support is affixed after the curing of the structural silicone and allows for simple completion of the weather seal silicone process.
FACADE 60 ASSEMBLYFLUSH GLAZING FRAME ASSEMBLY
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
27
FACADE 60 ASSEMBLYSEALANT USAGE CALCULATOR
DEPTH (mm) 2 3 4 5 8 10 12 15 20 25 30 40 502 75.0 50.0 37.5 30.0 18.8 15.0 12.5 10.0 7.5 6.0 5.0 3.8 3.03 50.0 33.3 25.0 20.0 12.5 10.0 8.3 6.7 5.0 4.0 3.3 2.5 2.04 37.5 25.0 18.8 15.0 9.4 7.5 6.3 5.0 3.8 3.0 2.5 1.9 1.55 30.0 20.0 15.0 12.0 7.5 6.0 5.0 4.0 3.0 2.4 2.0 1.5 1.26 25.0 16.7 12.5 10.0 6.3 5.0 4.2 3.3 2.5 2.0 1.7 1.3 1.08 18.8 12.5 9.4 7.5 4.7 3.8 3.1 2.5 1.9 1.5 1.3 0.9 0.810 15.0 10.0 7.5 6.0 3.8 3.0 2.5 2.0 1.5 1.2 1.0 0.8 0.615 10.0 6.7 5.0 4.0 2.5 2.0 1.7 1.3 1.0 0.8 0.7 0.5 0.420 7.5 5.0 3.8 3.0 1.9 1.5 1.3 1.0 0.8 0.6 0.5 0.4 0.3
DEPTH (mm) 2 3 4 5 8 10 12 15 20 25 30 40 502 246.1 164.0 123.0 98.4 61.5 49.2 41.0 32.8 24.6 19.7 16.4 12.3 9.83 164.0 109.4 82.0 65.6 41.0 32.8 27.3 21.9 16.4 13.1 10.9 8.2 6.64 123.0 82.0 61.5 49.2 30.8 24.6 20.5 16.4 12.3 9.8 8.2 6.2 4.95 98.4 65.6 49.2 39.4 24.6 19.7 16.4 13.1 9.8 7.9 6.6 4.9 3.96 82.0 54.7 41.0 32.8 20.5 16.4 13.7 10.9 8.2 6.6 5.5 4.1 3.38 61.5 41.0 30.8 24.6 15.4 12.3 10.3 8.2 6.2 4.9 4.1 3.1 2.510 49.2 32.8 24.6 19.7 12.3 9.8 8.2 6.6 4.9 3.9 3.3 2.5 2.015 32.8 21.9 16.4 13.1 8.2 6.6 5.5 4.4 3.3 2.6 2.2 1.6 1.320 24.6 16.4 12.3 9.8 6.2 4.9 4.1 3.3 2.5 2.0 1.6 1.2 1.0
WIDTH (mm)RUNNING METER PER 300ML CARTRIDGE
RUNNING FEET PER 300ML CARTRIDGEWIDTH (mm)
SEALANTS USAGE CALCULATOR
2.5
2.5
6 6
2
2
24.7
60.97
6.38
2
18
18
Use this calculator to work out the required silicone as the silicone is not included in the quote from Wispeco.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
28
Ensure the correct setting blocks are positioned in place before sealing applied.
FACADE 60 ASSEMBLYFLUSH GLAZING FRAME ASSEMBLY
5
5
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
29
To fit the Flush Glaze Toggle into the frame, hold at a slight angle & insert as shown in diagram A. Once inserted, the toggle can be straightened out.
100 100
Overall Transome width
Typical positions of the Flush Glaze Toggles & Spacers.
Positions of the Flush Glaze Spacer for the transomes. For transomes wider than 1800 mm, 4 x Flush Glaze Spacers need to be fitted with the F60 14 mm Spacer cut to the same length as the flush glaze spacer. Use the 6.3 x 24 Pressure Plate screws (Code: F60-PPS6.3x24)
FACADE 60 ASSEMBLYFITTING OF TOGGLES
To prevent the flush glaze toggle from slding down once inserted into the panel frame during handling & installation, cut & fit a small piece of 6 x 9 double sided tape under the toggle.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
30
130
100
2020
Corner Cleat
Corner Cleat
Flush Glaze Toggle
Flush Glaze Toggle
FACADE 60 ASSEMBLYLOCATION OF TOGGLES
6.3 x 24 Pressure Plate screws
To prevent the flush glaze toggle from slding down once inserted into the panel frame during handling & installation, cut & fit a small piece of 6 x 9 double sided tape between the 2 shorts legs as shown.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
31
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 07:52:29 AM, DWG To PDF.pc3
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 07:52:29 AM, DWG To PDF.pc3
Step 1: Fit the Flush Glaze Bottom Trim(continous) to the bottom row of transomes, as well as the 14 mm Spacer. Use the 6.3 x 24 Pressure Plate screws. (Code F60-PPS6.3x24)
Step 2: Insert into position the bottom row of panels, which will rest on top of the Flush Glaze Bottom Trim.(running full width of the bottom of the screen).
Step 3: Fit the Flush Glaze Spacer onto the next row of transomes. The Flush Glaze Toggles which are fitted to the sides of the panels can now also be fixed to the mullions.
Step 4: Fit the next row of flush glazed panels as shown, allowing the panels to rest on the Flush Glaze Spacers.
Step 5: Once all of the top row of panels is fitted, the top Flush Glaze Channel can be fitted, and then the perimeter silicone applied.
NB: The Flush Glaze Spacer cannot be fitted as shown above, as it is upside down, it will not be able to go into position.
FACADE 60 ASSEMBLYFITTING OF SPACERS
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 07:52:29 AM, DWG To PDF.pc3
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
32
1000
OR
AS
PE
R E
NG
.
D
75
FACADE 60 ASSEMBLYEXPANSION JOINTS
Ens
ure
that
th
e pr
essu
re
plat
e jo
int
over
laps
th
e m
ullio
n jo
int b
y m
in 2
5 m
m, b
ut d
o no
t fix
the
pres
sure
pla
te t
hat
over
laps
the
mul
lion
as th
is w
ill
prev
ent m
ovem
ent a
s re
quire
d.
PALIGHT FOAMED PVC (75 mm X 500 mm) to be fitted between the expansion profile & mullion as shown. (CODE: F60-EPS75MM)Hardware code: F60EPSPACER/75
100 mm Expansion Profile
Insert WEATHERSEAL gasket before fittingthe expansion profile into the mullions.(Use silicone spray for smoother sliding)
Note: An eng. must specify the correct fixing when fixing the expansion profiles to the mullions.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
33
130
1000
OR
AS
PE
R E
NG
.
D
130
14.6445
FACADE 60 ASSEMBLYEXPANSION JOINTS
Insert WEATHERSEAL gasket before fitting the expansion profile into the mullions.(Use silicone spray for smoother sliding)
160 mm & 190 mm Expansion Profile
Ens
ure
that
the
pres
sure
pla
te jo
int
over
laps
the
m
ullio
n jo
int b
y m
in 2
5 m
m, b
ut d
o no
t fix
the
pres
sure
pla
te
that
ov
erla
ps t
he m
ullio
n as
thi
s w
ill p
reve
nt m
ovem
ent
as
requ
ired.
Note: An eng. must specify the correct fixing when fixing the expansion profiles to the mullions.
PALIGHT FOAMED PVC (130 mm X 1000 mm) to be fitted between the expansion profile & mullion as shown.Hardware code: F60-EPS130MM
PALIGHT FOAMED PVC (130 mm X 1000 mm) to be fitted between the expansion profile & mullion as shown.Hardware code: F60-EPS130MM
Insert WEATHERSEAL gasket before fittingthe expansion profile into the mullions.(Use silicone spray for smoother sliding)
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
34
L
L
L
FACADE 60 ASSEMBLY
These fixing variations to be confirmed by an eng. as to what is suitable for each project
L (Expansion profile) = 1000 mm or as per eng.
Option 1 Option 2 Option 3
WINDLOAD & DEADLOAD BRACKETS
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
35
FACADE 60 ASSEMBLY
NOTE: All fixings to be specified by an engineer for intermediate anchors (Depicted anchors are for illustrative purposes only)
NOTE: All fixings to be specified by an engineer for intermediate anchors (Depicted anchors are for illustrative purposes only)
Slotted holes to be machined to suit the fixings. Drawing shows fixed intermediate anchor (deadload)
Deadload Bracket Windload Bracket
Slotted holes to be machined to suit the fixings. Drawing shows loose intermediate anchor (windload)
WINDLOAD & DEADLOAD BRACKETS
Recommended to fit Lock Washer
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
36
140
15 15
THCW Base PlateMachining detail for the 100 mm Mullion & Expansion Profile
30 90
52.25 35.5 52.25
3045
15
45
140
Ø6.5
Mach
ine sl
otted
hole
in the
base
plate
to su
it anc
hors
13.5
24
170
80
24
6
90 30
45
FACADE 60 ASSEMBLY
All fixings to be specified by an eng.
Option A100 mm Mullion
Option B
Machine slotted holes in the base plate to suit
MULLION BRACKET OPTIONS
Base Plate & Expansion profile for the 100 mm mullion
Min. height for expansion profile = 150 mm
W35122F60 Expansion Profile 100 mm
F60-PPS6.3X36No. 6.3 x 36 St . St. Screw for fixingbase plate to expansion profile
Recommended to fit Lock Washer
Note:The base plate expansion profiles are cut to a min. height of 150 mm, but may be required to be longer, please consult with the facade engineer for confirmation.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
37
140
15 15
THCW Base PlateMachining detail for the 160 mm Mullion & Expansion Profile
30
150
78
Mach
ine sl
otted
hole
in the
base
plate
to su
it anc
hors
2010
030
140
Ø6.5
52.5 35 52.5
13.5
Ø6.5
FACADE 60 ASSEMBLYMULLION BRACKET OPTIONS
Base Plate & Expansion profile for the 160 mm mullion
Min. height for expansion profile = 150 mm
F60-PPS6.3X36No. 6.3 x 36 St . St. Screw for fixingbase plate to expansion profile
W35178F60 Expansion Profile 160 mm
160 mm Mullion
Recommended to fit Lock Washer
Note:The base plate expansion profiles are cut to a min. height of 150 mm, but may be required to be longer, please consult with the facade engineer for confirmation.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
38
140
15 15
THCW Base PlateMachining detail for the 190 mm Mullion & Expansion Profile
30
Mach
ine sl
otted
hole
in the
base
plate
to su
it anc
hors
2525
180
130
52.5 35 52.5
140
9013
.5
Ø6.5
Ø6.5
FACADE 60 ASSEMBLYMULLION BRACKET OPTIONS
190 mm Mullion
Recommended to fit Lock Washer
F60-PPS6.3X36No. 6.3 x 36 St . St. Screw for fixingbase plate to expansion profile
Base Plate & Expansion profile for the 190 mm mullion
Min. height for expansion profile = 150 mm
Note:The base plate expansion profiles are cut to a min. height of 150 mm, but may be required to be longer, please consult with the facade engineer for confirmation.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
39
1000
OR
AS
PE
R E
NG
.
D
75
FACADE 60 MACHININGFABRICATION - EXPANSION PROFILES
Ensu
re
that
th
e pr
essu
re
plat
e jo
int
over
laps
th
e m
ullio
n jo
int
by m
in 2
5 m
m,
but
do n
ot fi
x th
e pr
essu
re p
late
th
at
over
laps
the
mul
lion
as t
his
will
pre
vent
mov
emen
t as
requ
ired.
1.1 Cut the mullions as per required length.
1.2 Cut the applicable expansion profiles 1000mm or as per eng.
1.3 Fit the GSL-WSF gasket to both ends of the expansion profile.
1.4 Slide the expansion profile into the one end of the mullion up to centre line of the expansion profile .
1.5 Slide the Palight foamed pvc up to half way into the mullion on both sides of the expansion profile as shown.
1.6 On the “V” groove of the mullion, fix bolt as per eng.
1.7 Slide the other mullion over the remaining part of the expansion profile leaving the required expansion joint.
1.8 Silicone the joint, especially the inside of the mullion where the glass is located as water is designed to drain down the inner wet chamber.
1.9 Ensure the correct fixing is used as per an eng. for the fixing of the expansion profile to the mullion.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
40
FACADE 60 SPECIFICATIONSGASKET & GLASS THICKNESS OPTIONS
24.76
6.38 8.38
22 20
2
0.76 2.76
0.97
1.03
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/23 12:44:48 PM, DWG To PDF.pc3
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
41
FACADE 60 MACHINING
1.1 Cut mullions & face plate all to the same required length.
3.1 Ensure all ends are deburred & all surfaces are clean before fitting together.
3.2 Position mullion face up, place face plate spacer on top, then fit face plate on top of face plate spacer. Always check that all 3 profiles sit correctly into one another.
3.3 Ensure the 3 profiles are all equal in length & do not overlap each other & fit firmly together.
2.1 Ensure 6 mm Diameter holes in the face plate have been punched out as shown.
2.2 Machining top and bottom of the face plate is required for flush glazing.
1
3
60
28
60
10.10
57.83
4.25
60
18
14
60
28
47
60
17.994.6
604060
40.2
88.2
4.1 Fix 6.3 x 20 St. St. self drilling tek screws with washers into the pre-punched holes, ensure tek screws are firmly fixed into the mullion. Always ensure that there is no burr when fixing the screws.
4.2 Ensure that the top & bottom screws are min. 50 mm from the ends of the profile.
Note: Where required, always drill dia. 6 mm holes in the face plate before fixing the tek screws to the mullions.
5. Cut the 14mm spacers (single glazing) 100 mm long to suit both the toggles & spacers.
3.1
3.2
4.2
4.1
3.3
4
2
5
FABRICATION - MULLIONS
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
42
FACADE 60 MACHINING
1. Cut the transome & transome face plate to the same required length except for the face plate spacer which is cut 20 mm shorter.
1
2.1 Ensure all ends are deburred & all surfaces clean before fitting together.
2.2 Cut the transome end caps according to the transome size & glue with the vulcanising glue to the face plate, ensure that the end cap is adequatly & securely fitted to prevent water penetration.
2.3 Position face plate spacer on top of transome, then fit face plate on top.
2.4 Ensure the 3 profiles are firmly positioned together .
3.1 Ensure dia. 6 mm holes are pre-drilled right through the face plate & the transomes, as these holes 20 mm from the ends of the transome are to accommodate the self drilling screws to fix into the spigots.
NB Transome clip-on cover is only fitted on site. (Remember to supply end caps for the clip-on cover)
Transomes ready to go to site for fitting onto spigots.
2
2.1
2.2
2.4
2.4
2
3.2 Fix 6.3 x 20 St. St. self drilling tek screws with washers into the pre-punched holes., ensure screws securely fitted to the transomes with no burr.
3.3 DO NOT fit the end screws on the transome as these holes are used to affix the transome to the Mullion-Transome Spigot.
3
FABRICATION - TRANSOMES
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
43
FACADE 60 MACHININGFABRICATION - SILL
1.1 Cut to length and ensure weep holes are machined as required. See relevant page for machinng of sill.
1.2 Slide Euro butterfly gasket into profile as shown. Use silicone spray for ease of fitting gasket.
1.3 Fit & silicone (structural silicone) end caps only when 2 sill s need to be joined together. (Preferable to silicone on site when joining).
1.4 Ensure that water can freely flow through drainage holes (no burrs or debris).
1.5 To prevent water leakage through 2 sills when joined together with the end cap, best to join on site. (Use structural silicone).
1
1.4
1.3
1.3
1.2
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
44
FACADE 60 MACHINING
Spigots
1
2.1 Fit the appropriate gaskets into the transomes. See the glazing chart.
2.2 Use the vulcanising glue to glue the gasket ends to the transome end caps.
NB: Always make sure the gaskets are cut an extra 6 mm to 8 mm longer, so as to bond firmly against the end cap.
1.1 Establish transome centres, see relevant page for correct positioning of spigots.
1.2 Fit pre-cut spigots using 5.5 x 70 St. St. Tek screws.
1.3 Ensure spigots are correctly positioned on the V-groove of the mullion.
1.4 Ensure correct orientation of the spigot & check that the spigot sits flush on the profile after fixing with the tek screws.
Note: Fasten the spigot to the mullion using the open port as this will allow minor adjustments to be made before complete fixation using the closed port.
Spigots can also be fitted on site using the Crealco Spigot jig specially designed for ease of fixing spigots to mullion. (only available for the 100 mm Mullion).
7.1
7.2
7.37.4
1.3
1.3
2
FABRICATION - SPIGOTS
2.2
2.2
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
45
TYPICAL DOUBLE GLAZING DETAIL
60
OUTSIDE
100
Various
50 -
50 m
m T
rans
ome
24.7
628
25
12.15
5650
25
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/09 11:21:16 AM, DWG To PDF.pc3
FACADE 60 SECTIONSHORIZONTAL - DOUBLE GLAZING
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
46
TYPICAL SINGLE GLAZING DETAIL
60
100
Various
50 -
50 m
m T
rans
ome
28
12.15
6.38
37
25 25
50
OUTSIDE
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/09 11:26:51 AM, DWG To PDF.pc3
FACADE 60 SECTIONSHORIZONTAL - SINGLE GLAZING
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
47
OUTS
IDE
60
506.38 28
12.6
15
30
50
Hei
ght o
f the
Flu
sh G
laze
Fra
me
(W57
643)
= T
rans
ome
Cen
tre to
Cen
tre -
21 4
5 (W
ill v
ary
for e
very
pro
ject
)60
Gla
ss H
eigh
t = T
rans
ome
Cen
tre to
Cen
tre -
26
22
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/10 11:46:03 AM, DWG To PDF.pc3
FACADE 60 SECTIONS
Section not to scale
VERTICAL - SINGLE GLAZING
OPT
ION
226
mm
spa
ces
betw
een
glas
s pa
nels
(Opt
ion
1 is
33
mm
bet
wee
n pa
nels
)
NOTE: Due to each project been unique, the ceiling detail will need to be considered with regards to the ceiling intergrating with the curtain wall.
NOTE: Due to each project been unique, the floor detail will need to be considered with regards to the finish floor level intergrating with the curtain wall.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
48
3090
OUTS
IDE
6.38
21
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/08/17 09:10:28 AM, DWG To PDF.pc3
30
FACADE 60 SECTIONSSILL - SEALING
NB:Extremely important to silicone seal across the entire sill as shown.
NOTE: Due to each project been unique, the floor detail will need to be considered with regards to the finish floor level intergrating with the curtain wall.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
49
TYPICAL SINGLE GLAZING DETAIL
60Various
25
50
OUTSIDE
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/27 03:32:45 PM, DWG To PDF.pc3
50
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/27 03:35:16 PM, DWG To PDF.pc3
NB:Extremely important to silicone seal across the entire sill as shown.
Apply structural silicone as shownwhere sill finishes against tubing.
FACADE 60 SECTIONSSILL - SEALING
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
50
60
OUTSIDE
100
50 -
50 m
m T
rans
ome
12.15
55.3
6
24.7
6 6.38
26
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/09 11:54:34 AM, DWG To PDF.pc3
FACADE 60 SECTIONSSINGLE DOUBLE GLAZING COMBO
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/09 12:00:26 PM, DWG To PDF.pc3
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
51
12
88 (for 100 mm Mullion)
148 (for 160 mm Mullion)
178 (for 190 mm Mullion)
FACADE 60 SECTIONS
100 mm Mullion 160 mm Mullion 190 mm Mullion
Positioning of sill according to the various mullions
SILL ASSEMBLY
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
52
OUTS
IDE
90
OUTS
IDE
16.5
30
905.5
2
FACADE 60 SECTIONSBASE PLATE
Extremely important to silicone seal across the entire sill as shown.
All fixings to be specified by an Engineer.
NOTE: Due to each project been unique, the floor detail will need to be considered with regards to the finish floor level intergrating with the curtain wall.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
53
TYPICAL BRACKET DETAILLOCK WASHER
ALL FIXINGS TO BE SPECIFIEDBY ENG.
170
80
OUTSIDE
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/23 01:28:24 PM, DWG To PDF.pc3
INTERMEDIATE MULLION BRACKET
FACADE 60 SECTIONS
W3297460 MM Mullion Bracket
All fixings to be specified by an Engineer.
Fitting of bracket fixings to mullion must be min. 50 mm from top or bottom of mullion.
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
54
OUTSIDE
OUTS
IDE
Max. 450
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/23 01:32:17 PM, DWG To PDF.pc3
50
50
24
243
FACADE 60 SECTIONS
NOTE: For all corner butt joint applications, the glass needs to be polished.
Fix a 50 x 50 x 3 thk flat as shown to stiffen corner joint
Detail A
See detail A
DETAILS-BUTT JOINT CORNER
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
55
OUTS
IDE
82
25
82
50
DETAILS-TRANSOME OVER AN OPENING
FACADE 60 SECTIONS
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
56
FACADE 60 SECTIONSDETAILS-DOOR INSERT
60
OUTSIDE
100
50 -
50 m
m T
rans
ome
28
12.15
6.38
37
30
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/23 01:39:20 PM, DWG To PDF.pc3
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
57
FACADE 60 SECTIONSDETAILS-DOOR INSERT
OUTS
IDE
63
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/23 01:40:17 PM, DWG To PDF.pc3
OUTS
IDE 30
71
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/23 01:51:38 PM, DWG To PDF.pc3
Option 2 - Using the Flush Glaze bottom Trim
This manual must be read in conjunction with the Installation, Cleaning & Maintenance Document and the Performance Certificates for the relevant system. The manual must also be used in conjunction with the design and cutting list from the latest version of StarFront.
Disclaimer: The right to make alterations is reserved© 2013 Wispeco (Pty) Ltd, All Rights Reserved
FACADE 60THERMAL FLUSH GLAZINGCURTAIN WALLING SYSTEM
crealco
PRODUCT MANUAL
58
FACADE 60 SECTIONSDETAILS-WINDOW INSERT
60
OUTSIDE
100
50 -
50 m
m T
rans
ome
28
12.15
6.38
37
30
C:\AA-LEE\AA-LEE\DRAW\WISPECO CURTAIN WALL\Curtain wall details-01.dwg, 2016/06/23 01:46:50 PM, DWG To PDF.pc3